Loading...
HomeMy WebLinkAboutR-394934U N J V) N z O V) ne w LL LL w J w a ,-1 M N 0 N 0 0 N 0 V) 0 0 U) a Ln N N i L0 a� v Q i N a� ra a a 0 c 0 ry N N i 00 V) +1 U L �I w 1\ 110/26/20221 JJM I RECORD DRAWING NO. I DATE I BY 35 30 25 20 15 10 11 STA G4+09 15.7LT 1-CB #60 I � I 12 STA G4+ 10, 10.2' LT 1-48" SDMH #44 II SSMH 77134 RIM 32.98 IE 26.4 N,S,E @ CL I RIM 32.61 I I O L IE 31.1 NW, 4 METAL IE 31.0 W, 6" CONC I U ACI 16 IE 30.5 SE, 4" METAL 114 1 1 a IE 30.8 N, 6" CONC �8 I SEE SHEET SD-9 FOR CONTINUATION al 0 N 1 I In / AC _ 00 48IN SDMH #21, SEE SHT SD-9 11 STA G 5+ 19 14.9' LNT Q I o 1 401 1-CB #23 I I I Qa / I C13 76401 SDMH 76592 a / N O I O / RIM 32.31 .. I �I — zi- ,1�0JI�?:h�i\affva`�`���-`I -'RIM -' ■■pl 32.15 :: Illlli .30.. �tilllY 1,=�I IIIIIII _ 1 rW1 O 0 iI 11 11 - ---- .. -� - S : • 1 1 �r I' �� - � Si •1 ►► :.� I�_��IIIIII`l_, loon . 32.74 1 -RIM ---P-/ AC I I 11STA G4+06, 19.7' RT/I 11 1-CB #61 H--, CB 76593 RIM 32.07 / IE 30.9 E, 6" ONC 11 STA G 5 + 14, 18.9' RT ry"� 322 1-CB #22 / PLAN 0 10 20 40 60 SCALE: 1"=20' AC i� �I a • _� • _ — • 11 ■I� — .. . 11 FOR CONTINUATION SEE SHEET SD-9 AC I ---_ 13' METAL & PLASTIC, "3RD STREET PROFESSI 325 321 d L M� (D m d (D EXIST GR z m c~i� Lon m ROW CL c~n Lon c~n Ln �m a X O cn X w X X w w ----- -- — X w ----- X X w w ---- X w a .. w P `-' X w O---- — -- ---- — — — — — (V a + (M � ( o o Q Q O Lr)� 109 LF 12" PP SD @ SLP=1.520lo w LLJ w 48" SDMH #44 w = STA G4+ 10, 10' LT Ln RIM=32.48 - . 48" SDMH #20 �48" IE(IN)12"(N)=26.49 STA G5+19, 9' LT SDMH #21 � - STA G5+39, 12' LT Q IE(IN)12"(E)=26.93 i!F-+8 RIM =32.42 +�j+"�T RIM=32.62 IE(IN)12"(W)=29.28 39-2 IE(IN)12"(N)=24.80 SEE SHT SD-9 IE(OUT)12"(S)=26.46IE(IN)12"(E)=27.03 2F.+4IE(IN)12"(W)=29.77 29.99 IE(OUT)12"(S)=24.79 20LF12"PP SD@ SLP=2.38% G3+20 G3+40 G3+60 G3+80 G4+00 G4+20 G4+40 G4+60 G4+80 G5+00 G5+20 G5+40 G5+60 G5+80 G6+00 PROFILE SCALE: 1"=20' HORIZ, 1"=5' VERT NOTICE SEO RECORD 0 Y2 1 DESIGNED DRAWINGS BAW DRAWN murra sm� IF THIS BAR DOES SEE NOTE ON NOT MEASURE 1" TTT THEN DRAWING IS CHECKED COVER SHEET NOT TO SCALE CONSTRUCTION NOTES: 1 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 11 INSTALL CB PER COR STD PLAN 200.00 12 INSTALL CB PER COR STD PLAN 201.00 16 PRIOR TO CONSTRUCTION, CONTRACTOR SHALL CONTACT CITY ENGINEER TO DETERMINE THE ACTUAL EXIST LATERAL STORM DRAIN LOCATION AND TO VERIFY IF THE EXIST STORM DRAIN LATERAL IS ACTIVE, IF STORM DRAIN LATERAL IS ACTIVE, RECONNECT EXIST PIPE TO NEW STORM DRAIN PIPE WITH NYLOPLAST FITTING OR APPROVED EQUAL, PER THE SPECIFICATIONS 1s EXIST FRANCHISE UTILITY TO BE RELOCATED BY OTHERS PRIOR TO CONSTRUCTION 19 SEE PROFILE 1 ON SHT SD-44 20 SEE PROFILE 2 ON SHT SD-44 40 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO 35 CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS 30 25 20 15 10 RENTON DOWNTOWN o UTILITY IMPROVEMENTS PROJECT WHITWORTH AVE S STORM PLAN & PROFILE STA G3+20 TO STA G6+00 R-394934 SHEET SD-20 34 of 121 no REVISION PROJECT NO.: 18-2251 I SCALE: AS SHOWN I DATE: JANUARY 2021