55
50
45
35
30
25
CB 30024
RIM 43.10
IE 38.7 NE, 6" CONC
IE 38.5 SW, 6" CONC
z /
X
0
z
n
SDMH 85661
I I I RIM 45.37
IE 41.7 S, 8" CONC
IE 40.0 SE, 8" CONC
CB #68, SEE SHT SD-24 IE 38.9 W, 12" CONC
j IE 38.8 E, 12" CONC
SDMH #48, SEE SHT SD-24 I O I � � CB 85662
SSMH 85682 ' I RIM 44.97
RIM 46.04 � I IE 42.9 NW, 8" CONC
100 Q I � � IF 49 a N 8" CONC
CB 30025 IE 38.2 NE,E,S-W @ CL .� I N� 1 11 STA L4+61 14.8' IT
Jo RIM 43.27
� IE 41. NE, 6" IRON � w � �
8' BUS SIGN - I GAS WILL BE
REESTABLISHED .PERIN CDNR 20 DEACTIVATED BY ASE3 QARK
a ° ° a a PSE PRIOR TO I
� a I ° PERMIT 7373-18"T x 6"W '° +
° 1 �p CONSTRUCTION 16 .W CI +
I N � I
���-69- 7V - - -
I _ _ _
N
\ -
45 65 I 4- 6` - M -- L#36 Qp
L1+00 I L2+00 ... .... .... L3+00 .... .... Q I 3 �::. ::u) -� ... cn
4+00 cn U
�\ oJ, .... .... .... I : .I .... .... • r , :. 1 TYP .... .... .... SS S£_2iaS ��8 -� _ _ SS d IDNZT�.- z =
\ I MILL AVE S I o I� ' 'r •16 �'
r, Jw
G- - - - - - - „ - - - - - - - G I-
UGP- - -- - _- _ _ - -
T= = _ �- O
\- M M I TT 7Q
45_ °m SDMH #47, SEE SHT SD-24 Y I I I I
\ o �
1023 1010 to • � I \ o RI 855 4
I RIM 44. 2
�. 2 I IE 42.0 S, 8" CONC
B 3 66 RVI I C-�• IE 42.0 N, 8" CONC
43.10 1 :15SDMH 85622
IE 42.0 NE�6" CONC STA L4+31, 17.4' RT I:: 12-
I
1-CB #65 ° 1 RIM 45.46
IE 42.0 S, 8' CONC
I I I I T
I IE 39.0 W, 1 CONC
Q IE 38.8 E, 1 CONC
4" LATERAL FOUND AND 11 STA L4+60 17.5RT i N Z I o
1-CB #66 II
II
RECONNECTED AT STA 4+43 o • I I N I
I
a N.II� �
FOR CONTINUATION
PLAN SEE SHEET SD-24
0 10 20 40 60
SCALE: 1"=20'
w
F-
z
w
0
z
0
0
°
Ia
CD ...
12"DI W -6 4
0
RECORD DRAWINGS SHOW CONTRACTOR
SURVEYED STRUCTURE LOCATIONS AND
CD
p
ELEVATIONS. THE ORIGINAL DESIGN
CO
LOCATIONS AND ELEVATIONS ARE INDICATED
uU)i
J
WITH STRIKETHROUGH TEXT. REFER TO
�,
`ONr'j.
� m
CONTRACT DOCUMENTS FOR ADDITIONAL
N
U � �
N
DETAILS
�
N � V)� V)m
< o
X
a X X X X X
(/) �
EXIST
GR @
w0
w w w w -w
W w
ROW
CL
a
SDR 35
29 LF
12"e9E)E)
J w
----------
---- @SLP=0.72%
�
SDR 35
15
LF 12"PP-SE) @
SLP=4.700/(o
CB #67
SPU CRP
BEYOND
%
STA L4+61, 15' LT
RIM=45.03
IE(IN)12"(S)=41.50
IE(OUT)12"(W)=41.4'
CB #66
STA L4+60, 17' RT
48" SDMH #47 RIM=45.02
STA L4+16, 14' RT IE(IN)12"(E)=41.24
RIM=45.46 CB #65 IE(OUT)12"(N)=40.11
IE(IN)12"(S)=39.16 STA K3+07, 35' RT
IE(IN)12"(W)=39.11 RIM=44.92 -
39-i!8
IE(OUT)24"(E)=39.93 IE(IN)12"(S)=39.90
rFrni IT)1 ')"(1\1)=-�4 Rz�T
LO+40 LO+60 LO+80 L1+00 L1+20 L1+40 L1+60 L1+80 L2+00 L2+20 L2+40 L2+60 L2+80 L3+00 L3+20 L3+40 L3+60 L3+80 L4+00 L4+20 L4+40 L4+60 L4+80
PROFILE
SCALE: 1"=20' HORIZ, 1"=5' VERT
NOTICE SEO RECORD
0 �z 1 DESIGNED DRAWINGS
BAW
sm�
IF THIS BAR DOES DRAWN SEE NOTE ON
NOT MEASURE 1" TTT murra
THEN DRAWING IS CHECKED COVER SHEET
1 10/26/2022 JJM RECORD DRAWING NOT TO SCALE
NO. DATE BY REVISION
55
50
45
a 35
25
CONSTRUCTION NOTES
O CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY
CONTROL PLAN, SHT G-5
11 INSTALL CB PER COR STD PLAN 200.00
16 PRIOR TO CONSTRUCTION, CONTRACTOR SHALL
CONTACT CITY ENGINEER TO DETERMINE THE ACTUAL
EXIST LATERAL STORM DRAIN LOCATION AND TO
VERIFY IF THE EXIST STORM DRAIN LATERAL IS ACTIVE,
IF STORM DRAIN LATERAL IS ACTIVE, RECONNECT
EXIST PIPE TO NEW STORM DRAIN PIPE WITH
NYLOPLAST FITTING OR APPROVED EQUAL, PER THE
SPECIFICATIONS
19 SEE PROFILE 6 ON SHT SD-44
20 SEE PROFILE 7 ON SHT SD-44
R-394937
SHEET
PROJECT
RENTON DOWNTOWN MILL AVE S
® UTILITY STORM PLAN &PROFILE SD-25
� IMPROVEMENTS STA LO+00 TO STA L4+80
PROJECT NO.: 18-2251 SCALE: AS SHOWN DATE: JANUARY 2021 37 Of 121