STRUCTURAL NOTES
(THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS)
CODE
ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS,
SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION. SPECIFICATIONS AND STANDARDS
WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION.
DESIGN LOADS
DEAD LOADS:
STRUCTURE SELF WEIGHT
LIVE LOADS:
TRAFFIC 250 PSF, HS-20
SEE PLANS FOR ADDITIONAL DESIGN LOADS.
STATEMENT OF SPECIAL INSPECTIONS
SPECIAL INSPECTIONS ARE REQUIRED AS INDICATED IN THE FOLLOWING TABLE. THE CONTRACTOR SHALL SUBMIT A
WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND OWNER PRIOR TO COMMENCEMENT OF
WORK IN ACCORDANCE WITH CHAPTER 1704.4 OF THE IBC.
CONCRETE CONSTRUCTION - SPECIAL INSPECTION IS REQUIRED IN CONFORMANCE WITH IBC SECTION 1705.3 AND
TABLE 1705.3.
���:Lyre��l►���x.�:r•�►rr•�:irure�x•�.u�����:�v��y:ra�■ �:reel►u�r.�e�:a.>ti►�:a�y�xyre��i►���x.�:r•�►�re� ��:r �:Ir•���u
STRUCTURAL OBSERVATION OF THE STRUCTURAL SYSTEM BY THE ENGINEER IS NOT REQUIRED.
FOUNDATIONS:
SOILS REPORT: REPORT NO: 20181376.003A
PREPARED BY: KLEINFELDER
DATED: JAN 20, 2020
ALLOWABLE PILE CAPACITY: 10 TONS (PER GEOTECH)
LATERAL EARTH PRESSURE (MANHOLES):
AT -REST ABOVE GROUND WATER: 65 PCF
AT -REST BELOW GROUND WATER: 96 PCF
DESIGN GROUND WATER DEPTH: 6' BELOW GRADE
LATERAL EARTH PRESSURE (CULVERT PENETRATION & STRONGBACK):
AT -REST ABOVE GROUND WATER: 65 PCF + ANY APPLICABLE SURCHARGE
AT -REST BELOW GROUND WATER: 34 PCF + HYDROSTATIC PRESSURE
IMPORTED STRUCTURAL FILL AND BACKFILL MATERIAL SHOULD CONSIST OF CLEAN, WELL GRADED GRANULAR
MATERIAL FREE OF DEBRIS OR ORGANICS. REFER TO GEOTECHNICAL REPORT FOR SPECIFICS.
4" 0 PIPE PILING INSTALLATION
4" SCHEDULE 160 UNCOATED PIPE SHALL CONFORM TO ASTM A53 GRADE A, FY = 35 KSI (MIN)
PIPE PILING SHALL BE DRIVEN INTO THE SUBGRADE TO A POINT OF REFUSAL WITH REFUSAL CRITERIA DETERMINED
BASED ON HAMMER SIZE SELECTED BY THE CONTRACTOR, AND A STATIC LOAD TEST PROGRAM. REFER TO
GEOTECHNICAL REPORT.
MINIMUM LAPS AND EMBEDMENT
UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS SHALL BE AS TABULATED
BELOW:
f'c = 4000 PSI
DEVELOPMENT LENGTH
LAP SPLICE
BAR
TENSION
COMPRESSION
TENSION
COMPRESSION
SIZE
TOP BARS
THE
BARS
ALL BARS
TOP BARS
BARS
ALL BARS
#3
22
17
9
28
22
12
#4
29
22
11
37
29
15
#5
36
28
14
47
36
19
#6
43
33
17
56
43
23
#7
63
48
20
81
63
27
#8
72
55
22
93
72
30
NOTE:
1. ALL LENGTHS ARE IN INCHES.
2. ALL LAP SPLICES ARE CLASS B.
3. "TOP BARS" ARE HORIZONTAL REINFORCEMENT PLACED SUCH THAT MORE THAN 12 INCHES OF
CONCRETE IS CAST IN THE MEMBER BELOW THE BAR.
PIPE SECTIONS SHALL BE CONNECTED WITH COMPRESSION FITTED SLEEVE COUPLERS. REFER TO GEOTECHNICAL CONCRETE COVER ON REINFORCING
FREQUENCY AND DISTRIBUTION OF REPORTS - INSPECTION REPORTS SHALL BE PROVIDED FOR EACH DAY ON SITE BY REPORT.
SPECIAL INSPECTOR. STRUCTURAL OBSERVATION REPORTS SHALL BE PROVIDED AFTER EACH OBSERVATION. REPORTS CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3"
SHALL BE DISTRIBUTED TO THE CONTRACTOR, ENGINEER AND BUILDING OFFICIAL. CONCRETE
SPECIAL INSPECTION
OPERATION
CONT
PERIODIC
REMARKS
SOILS
SHORING (WHERE REQUIRED)
X
GEOTECH ENGINEER
EXCAVATION & FILL & COMPACTION
X
GEOTECH ENGINEER
PIPE PILING INSTALLATION
X
PILING REFUSAL VERIFICATION
X
CONCRETE
REINFORCING PLACEMENT
X
CONCRETE TEST SPECIMENS
X
CONCRETE PLACEMENT
X
EPDXY ANCHORS
X
STRUCTURAL STEEL
FABRICATION & ERECTION
X
ALL WELDING
X
NOTE:
ALL ITEMS MARKED WITH AN "X" SHALL BE INSPECTED IN ACCORDANCE WITH IBC CHAPTER 17. SPECIAL
INSPECTION SHALL BE PERFORMED BY A QUALIFIED TESTING AGENCY DESIGNATED BY THE OWNER. THE
STRUCTURAL ENGINEER AND BUILDING OFFICIAL SHALL BE FURNISHED WITH COPIES OF ALL RESULTS. ANY
INSPECTION FAILING TO MEET THE PROJECT SPECIFICATIONS SHALL BE IMMEDIATELY BROUGHT TO THE
ATTENTION OF THE DESIGN TEAM.
SHOP DRAWINGS
SHOP DRAWINGS FOR THE FOLLOWING ITEMS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW
PRIOR TO FABRICATION:
1. REINFORCING STEEL
2. CONCRETE MIX DESIGN
3. STRUCTURAL STEEL
SHOP DRAWINGS SHALL BE REVIEWED, REVISED AS REQUIRED FOR FIELD CONDITIONS, AND DATE STAMPED BY THE
CONTRACTOR PRIOR TO REVIEW BY THE ENGINEER. CONTRACTOR SHALL PROVIDE (3) SETS OF SHOP DRAWINGS FOR
ENGINEER'S REVIEW. ALLOW TWO WEEKS FOR SHOP DRAWING APPROVAL BY ENGINEER.
ENGINEER'S SHOP DRAWING REVIEW IS FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT AND CONTRACT
DOCUMENTS. MARKINGS OR COMMENTS SHALL NOT BE CONSTRUED AS RELIEVING THE CONTRACTOR FROM
COMPLIANCE WITH THE PROJECT PLANS AND SPECIFICATIONS. THE CONTRACTOR REMAINS RESPONSIBLE FOR
DETAILS AND ACCURACY, FOR CONFORMING AND CORRELATING ALL QUANTITIES AND DIMENSIONS, FOR
SELECTING FABRICATION PROCESSES, FOR TECHNIQUES OF ASSEMBLY, AND FOR PERFORMING THE WORK IN A SAFE
MANNER.
ENGINEER'S SHOP DRAWING REVIEW OF STRUCTURAL COMPONENTS DESIGNED BY OTHERS IS FOR LOADS IMPOSED
ON THE BASIC STRUCTURE. THE COMPONENT DESIGNER IS RESPONSIBLE FOR CODE CONFORMANCE AND ALL
CONNECTIONS TO THE BASIC STRUCTURE. SHOP DRAWINGS SHALL INDICATE MAGNITUDE AND DIRECTION OF THE
LOADS IMPOSED ON THE BASIC STRUCTURE AND SHALL BE STAMPED & SIGNED BY A PROFESSIONAL ENGINEER
REGISTERED IN THE SAME STATE AS THE PROJECT.
FABRICATION SHALL BEGIN ONLY AFTER SHOP DRAWINGS BEARING THE STAMP AND SIGNATURE OF THE PROJECT
ENGINEER OF RECORD AND CONTRACTOR HAVE BEEN RECEIVED.
O 6
ENGINES RING
250 4TH AVE. S., SUITE 200
EDMONDS, WASHINGTON 98020
PHONE (425) 778-8500
FAX (425) 778-5536
1 03/15/23 JGG RECORD DRAWINGS
NO. DATE BY REVISION
NOTICE
0 % 1
IF THIS BAR DOES
NOT MEASURE 1"
THEN DRAWING IS
NOT TO SCALE
ALL CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED, AND PLACED IN ACCORDANCE WITH CHAPTER 26 OF
ACI 318 AND THE AMERICAN CONCRETE INSTITUTE'S SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS
(ACI 301).
ALL CONCRETE SHALL BE STONE -AGGREGATE CONCRETE HAVING A UNIT WEIGHT OF APPROXIMATELY 150 POUNDS
PER CUBIC FOOT.
CONCRETE STRENGTHS AT 28 DAYS (fc) AND MIX CRITERIA SHALL BE AS FOLLOWS:
MAXIMUM
MIN CEMENT
TYPE OF CONSTRUCTION
f'c
WATER/CEMENT
CONTENT PER CUBIC
MAXIMUM
SHRINKAGE STRAIN
RATIO
YARD
WALLS
4000 PSI
0.50
6 SACK
N/A
ELEVATED SLABS
4000 PSI
0.50
6 SACK
N/A
BEAMS
4000 PSI
0.50
6 SACK
N/A
THE MINIMUM AMOUNT OF CEMENT LISTED ABOVE MAY BE CHANGED IF A CONCRETE PERFORMANCE MIX IS
SUBMITTED TO THE ENGINEER AND THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO PLACING
ANY CONCRETE. THE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE AND COARSE
AGGREGATE, WATER, AND ADMIXTURES AS WELL AS THE WATER -CEMENT RATIO, SLUMP, CONCRETE YIELD, AND
SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH CHAPTER 26 OF ACI 318.
ALL CONCRETE EXPOSED TO WEATHER OR TO FREEZING TEMPERATURES SHALL BE AIR -ENTRAINED IN ACCORDANCE
WITH ACI 318 TABLE 19.3.3.1 FOR MODERATE EXPOSURE CLASS F1.
REINFORCING STEEL
REINFORCING STEEL SHALL BE DEFORMED BILLET STEEL CONFORMING TO ASTM A615, AND SHALL BE GRADE 60 (Fy
= 60,000 PSI), UNLESS NOTED OTHERWISE. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED
SHALL CONFORM TO ASTM A706. REINFORCING COMPLYING WITH ASTM A615 MAY BE WELDED IF MATERIAL
PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN AWS D1.4 ARE
SUBMITTED.
REINFORCING STEEL SHALL BE DETAILED INCLUDING HOOKS AND BENDS IN ACCORDANCE WITH SP-66 AND ACI
318R, LATEST EDITIONS. UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS
SHALL BE PER SCHEDULE.
MECHANICAL SPLICING OF REINFORCING BARS, WHERE INDICATED ON THE DRAWINGS, SHALL BE BY AN ICBO
APPROVED SYSTEM, SHALL DEVELOP 125% OF THE SPECIFIED YIELD STRENGTH OF THE BAR, AND SHALL BE
INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
REINFORCING SHALL BE PLACED AND ADEQUATELY SUPPORTED PRIOR TO PLACING CONCRETE. WET -SETTING
EMBEDDED ITEMS IS NOT ALLOWED WITHOUT PRIOR ENGINEER APPROVAL. BARS PARTIALLY EMBEDDED IN
HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR APPROVED BY THE STRUCTURAL
ENGINEER. REFER TO CHAPTER 7 OF ACI 318 FOR OTHER REINFORCING STEEL REQUIREMENTS.
NON -SHRINK GROUT
NON -SHRINK GROUT SHALL BE CEMENT -BASED WITH A MINIMUM COMPRESSIVE STRENGTH OF 6000 PSI WHEN
TESTED IN ACCORDANCE WITH ASTM C-109. GROUT SHALL BE MIXED AND PLACED IN STRICT ACCORDANCE WITH
THE MANUFACTURER'S RECOMMENDATIONS.
IVIK
�E C 0
D
DES GNED
JEG
D �Al�� �V G S
DRAWN
JGG
SEE IIOUE DIM
CHECKED
COYER SHEFU
murra,!sm�rth
CONCRETE EXPOSED TO EARTH AND WEATHER:
#6 BARS AND LARGER 2"
#5 BARS AND SMALLER 1 1/2"
CONCRETE NOT EXPOSED TO EARTH OR WEATHER:
SLABS, WALLS AND JOISTS 3/4"
COLUMN TIES OR SPIRALS AND BEAM STIRRUPS 1 1/2"
CONCRETE GENERAL NOTES
PROVIDE CORNER BARS TO MATCH THE HORIZONTAL REINFORCING WITH TENSION LAP SPLICE AT EACH SIDE PER
TABLE, OR BEND ONE SIDE OVER TO PROVIDE TENSION LAP.
ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED AND PROPERLY PREPARED IMMEDIATELY PRIOR TO
POURING OF CONCRETE. DOWEL STEEL SHALL BE THE SAME SIZE AND SPACING AS MAIN REINFORCING DETAILED
BEYOND JOINT.
BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR
APPROVED BY THE STRUCTURAL ENGINEER.
STRUCTURAL STEEL
STRUCTURAL STEEL DESIGN, FABRICATION AND ERECTION SHALL BE IN ACCORDANCE WITH THE AISC
"SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS", LATEST
EDITION.
PLATES, ANGLES, AND RODS SHALL CONFORM TO ASTM A36, Fy = 36 KSI.
STRUCTURAL TUBING SHALL CONFORM TO ASTM A500 GRADE B, Fy = 46 KSI.
BOLTS CONNECTING STEEL MEMBERS SHALL CONFORM TO ASTM A325-N. BOLTS SHALL BE 3/4"0 MINIMUM, UNO
ANCHOR BOLTS SHALL CONFORM TO ASTM A307.
CONTRACTOR SHALL PROVIDE CONNECTION ADJUSTMENT TOLERANCES TO SATISFY THE REQUIREMENTS OF AISC
MANUAL OF STEEL CONSTRUCTION.
UNLESS SPECIFIED AS STAINLESS STEEL, ALL STEEL MEMBERS, SHAPES, BOLTS, AND ACCESSORIES EXPOSED TO
WEATHER, EARTH, OR MOISTURE SHALL BE HOT DIP GALVANIZED.
WELDING
WELDING SHALL CONFORM TO AWS "STRUCTURAL WELDING CODE", LATEST EDITION. ALL WELDING SHALL BE
DONE WITH 70 KSI LOW HYDROGEN ELECTRODES. WHERE NOT CALLED OUT, MINIMUM FILLET WELD SIZE SHALL BE
PER TABLE 5.8 IN AWS D1.1, LATEST EDITION.
WELDING OF REINFORCING BARS SHALL NOT BE PERMITTED UNLESS SPECIFICALLY CALLED OUT ON DRAWINGS OR
APPROVED BY STRUCTURAL ENGINEER. WELDING OF GRADE 60 REINFORCING BARS SHALL BE PERFORMED USING
LOW HYDROGEN ELECTRODES. WELDING OF GRADE 40 REINFORCING BARS SHALL BE PERFORMED USING E70XX
ELECTRODES. SEE REINFORCING NOTES FOR MATERIAL REQUIREMENTS OF WELDED BARS. WELDING WITHIN 4" OF
COLD BENDS IN REINFORCING BARS IS NOT PERMITTED.
ALL WELDING SHALL BE DONE BY WASHINGTON ASSOCIATION OF BUILDING OFFICIALS (WABO) CERTIFIED WELDERS.
EXISTING STRUCTURE
CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING STRUCTURE
DEPICTED IN THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE
REDESIGN.
CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING MATERIAL IS PENETRATED OR
REMOVED. PROVIDE WATER PROOFING AS REQUIRED.
i
• RENTON DOWNTOWN
� UTILITY
IMPROVEMENTS
PROJECT
GENERAL
STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ALL OTHER DRAWINGS FOR BIDDING AND
CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS FOR COMPATIBILITY BEFORE
PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING.
CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL
PERMANENT SUPPORT AND STIFFENING ARE INSTALLED.
CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ENGINEER FOR APPROVAL PRIOR TO
FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS
REQUIREMENT.
DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT
SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF
CONSTRUCTION SHALL BE USED, SUBJECTTO REVIEW AND APPROVAL BY THE ENGINEER.
LEGEND
DEFINITION
SYMBOL
DEFINITION
SYMBOL
NATIVE SOIL
STRUCTURAL STEEL
I I e=l I e_l I �_l I
GRANULAR FILL
RATED SHEATHING
CONCRETE WALL
ABBREVIATIONS
(A)
ABOVE
ANCHOR BOLT
GLIB
GLUE -LAMINATED BEAM
HORIZONTAL
AB
HORIZ
ALT
ALTERNATE
ARCHITECT
HSS
HOLLOW STRUCTURAL SECTION
ARCH
KIP
KING POST
(B)
BELOW
KSI
KIPS PER SQUARE INCH
ANGLE
MECHANICAL
BD
BAR DIAMETER
L
BLKG
BLOCKING
MECH
BM
BEAM
BOTTOM
MF
MOMENT FRAME
BOT
MTL
METAL
BRING
BEARING
BETWEEN
NS
NEAR SIDE
BTWN
OC
ON CENTER
CJP
COMPLETE JOINT PENETRATION
CLEAR
OPP
OPPOSITE
CLR
PL
PLATE
CMU
CONCRETE MASONRY UNIT
PLCS
PLACES
COL
COLUMN
PSI
POUNDS PER SQUARE INCH
CONC
CONCRETE
PSF
POUNDS PER SQUARE FOOT
CONN
CONNECTION
CONTINUOUS
P/T
POST TENSIONED
CONT
PT
PRESSURE TREATED
COORD
COORDINATE
DOUBLE
REINF
REINFORCING
REQUIRED
DBL
REQ'D
DIET
DETAIL
SCHED
SCHEDULE
DIA
DIAMETER
SIM
SIMILAR
DIM
DIMENSION
SOG
SLAB ON GRADE
DIR
DIRECTION
STD
STANDARD
EA
EACH
STIFF
STIFFENER
ELEV
ELEVATION
STL
STEEL
ES
EACH SIDE
SYMM
SYMMETRICAL
EX
EXISTING
SW
SHEARWALL
EXP
EXPANSION
TOC
TOP OF CONCRETE
FLR
FLOOR
TOS
TOP OF STEEL
FDN
FOUNDATION
TOW
TOP OF WALL
FTG
FOOTING
TYP
TYPICAL
FS
FAR SIDE
UNO
UNLESS NOTED OTHERWISE
VERTICAL
GC
GENERAL CONTRACTOR
VERT
WF
WIDE FLANGE
RECORD DRAWING
THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED
ON CONSTRUCTION RECORDS AND AS -BUILT
INFORMATION PROVIDED BY OTHERS. CG ENGINEERING
HAS NOT VERIFIED THE ACCURACY AND/OR
COMPLETENESS OF THIS INFORMATION.
STRUCTURAL NOTES
R-394945
SHEET
SD-50
45 of 121
L
PROJECT NO.: 18-2251 I SCALE: AS SHOWN I DATE: MARCH 2O23