STRUCTURAL NOTES
(THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS)
CODE
ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS,
SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION. SPECIFICATIONS AND STANDARDS
WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION.
DESIGN LOADS
DEAD LOADS:
LIGHT POLE 300 LBS (INCLUDES LUMINAIRE, POLE, SIGN AND FLOWER POTS)
EARTHQUAKE LOADS:
EQUIVALENT LATERAL FORCE PROCEDURE PER ASCE 7-10 SECTION 12.8.
SITE CLASS (ASSUMED)
D
SHORT PERIOD SPECTRAL RESPONSE ACCEL (SS)
1.440
ONE SECOND SPECTRAL RESPONSE ACCEL (Si)
0.538
SHORT PERIOD DESIGN SPECTRAL RESPONSE ACCEL (SDS)
0.960
ONE SECOND DESIGN SPECTRAL RESPONSE ACCEL (SDI)
0.538
RISK CATEGORY
II
SEISMIC IMPORTANCE FACTOR 00
1.0
SEISMIC DESIGN CATEGORY
D
BASIC SEISMIC FORCE -RESISTING -SYSTEM
POLE
RESPONSE MODIFICATION FACTOR, (R)
1.0
REDUNDANCY FACTOR (p)
1.0
SEISMIC RESPONSE COEFFICIENT (CS)
0.768
W = TOTAL SEISMIC DEAD LOAD AS DEFINED PER ASCE 7-10 SECTION 12.7.2.
WIND LOADS:
BASIC WIND SPEED (3 SECOND GUST) 110 MPH
EXPOSURE B
KZT 1.0
SUBMITTAL ITEMS
SHOP DRAWINGS FOR THE FOLLOWING ITEMS SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW PRIOR TO
FABRICATION:
1. LIGHT POLE
REINFORCING STEEL
REINFORCING STEEL SHALL BE DEFORMED BILLET STEEL CONFORMING TO ASTM A615, AND SHALL BE GRADE 60 (Fy
= 60,000 PSI), UNLESS NOTED OTHERWISE. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED
SHALL CONFORM TO ASTM A706. REINFORCING COMPLYING WITH ASTM A615 MAY BE WELDED IF MATERIAL
PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN AWS D1.4 ARE
SUBMITTED.
REINFORCING STEEL SHALL BE DETAILED INCLUDING HOOKS AND BENDS IN ACCORDANCE WITH SP-66 AND ACI
318R, LATEST EDITIONS. UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS
SHALL BE PER SCHEDULE.
REINFORCING SHALL BE PLACED AND ADEQUATELY SUPPORTED PRIOR TO PLACING CONCRETE. WET -SETTING
EMBEDDED ITEMS IS NOT ALLOWED WITHOUT PRIOR ENGINEER APPROVAL. BARS PARTIALLY EMBEDDED IN
HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR APPROVED BY THE STRUCTURAL
ENGINEER. REFER TO CHAPTER 7 OF ACI 318 FOR OTHER REINFORCING STEEL REQUIREMENTS.
MINIMUM LAPS AND EMBEDMENT
UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS SHALL BE AS TABULATED
BELOW:
f c = 3000 PSI
DEVELOPMENT LENGTH
LAP SPLICE
BAR
TENSION
COMPRESSION
TENSION
COMPRESSION
SIZE
TOP BARS
OTHER
BARS
ALL BARS
TOP BARS
OTHER
BARS
ALL BARS
#3
22
17
9
28
22
12
#4
29
22
11
37
29
15
#5
36
28
14
47
36
19
#6
43
33
17
56
43
23
#7
63
48
20
81
63
27
#8
72
55
22
93
72
30
NOTE:
1. ALL LENGTHS ARE IN INCHES.
2. ALL LAP SPLICES ARE CLASS B.
3. "TOP BARS" ARE HORIZONTAL REINFORCEMENT PLACED SUCH THAT MORE THAN 12 INCHES OF
CONCRETE IS CAST IN THE MEMBER BELOW THE BAR.
SHOP DRAWINGS SHALL BE REVIEWED, REVISED AS REQUIRED FOR FIELD CONDITIONS, AND DATE STAMPED BY THE
CONTRACTOR PRIOR TO REVIEW BY THE ENGINEER. ALLOW TWO WEEKS FOR SHOP DRAWING APPROVAL BY CONCRETE COVER ON REINFORCING
ENGINEER.
CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3"
ENGINEER'S SHOP DRAWING REVIEW IS FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT AND CONTRACT
DOCUMENTS. MARKINGS OR COMMENTS SHALL NOT BE CONSTRUED AS RELIEVING THE CONTRACTOR FROM
COMPLIANCE WITH THE PROJECT PLANS AND SPECIFICATIONS. THE CONTRACTOR REMAINS RESPONSIBLE FOR
DETAILS AND ACCURACY, FOR CONFORMING AND CORRELATING ALL QUANTITIES AND DIMENSIONS, FOR
SELECTING FABRICATION PROCESSES, FOR TECHNIQUES OF ASSEMBLY, AND FOR PERFORMING THE WORK IN A SAFE
MANNER.
ENGINEER'S SHOP DRAWING REVIEW OF STRUCTURAL COMPONENTS DESIGNED BY OTHERS IS FOR LOADS IMPOSED
ON THE BASIC STRUCTURE. THE COMPONENT DESIGNER IS RESPONSIBLE FOR CODE CONFORMANCE AND ALL
CONNECTIONS TO THE BASIC STRUCTURE.
CONCRETE
ALL CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED, AND PLACED IN ACCORDANCE WITH CHAPTER 26 OF
ACI 318 AND THE AMERICAN CONCRETE INSTITUTE'S SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS
(ACI 301).
ALL CONCRETE SHALL BE STONE -AGGREGATE CONCRETE HAVING A UNIT WEIGHT OF APPROXIMATELY 150 POUNDS
PER CUBIC FOOT.
CONCRETE STRENGTHS AT 28 DAYS (Pc) AND MIX CRITERIA SHALL BE AS FOLLOWS:
MAXIMUM
MIN CEMENT
TYPE OF CONSTRUCTION
f'c*
WATER/CEMENT
CONTENT PER CUBIC
MAXIMUM
SHRINKAGE STRAIN
RATIO
YARD
FOOTINGS
3000 PSI
0.55
5 1/2 SACK
N/A
THE MINIMUM AMOUNT OF CEMENT LISTED ABOVE MAY BE CHANGED IF A CONCRETE PERFORMANCE MIX IS
SUBMITTED TO THE ENGINEER AND THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO PLACING
ANY CONCRETE. THE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE AND COARSE
AGGREGATE, WATER, AND ADMIXTURES AS WELL AS THE WATER -CEMENT RATIO, SLUMP, CONCRETE YIELD, AND
SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH CHAPTER 26 OF ACI 318.
ALL CONCRETE EXPOSED TO WEATHER OR TO FREEZING TEMPERATURES SHALL BE AIR -ENTRAINED IN ACCORDANCE
WITH ACI 318 TABLE 19.3.3.1 FOR MODERATE EXPOSURE CLASS F1.
*PROVIDE Pc SPECIFIED IN TABLE FOR DURABILITY REQUIREMENTS. 2500 PSI CONCRETE MEETS STRENGTH
REQUIREMENTS, THEREFORE SPECIAL INSPECTION IS NOT REQUIRED.
O 6
ENGINES RING
250 4TH AVE. S., SUITE 200
EDMONDS, WASHINGTON 98020
PHONE (425) 778-8500
FAX (425) 778-5536
#5 VERT BARS
#4 TIES
.... dT POLE BY
E PLATE AND
=FENER PLATES BY
dT POLE MFR
CONCRETE EXPOSED TO EARTH AND WEATHER:
#6 BARS AND LARGER 2" I I FINISHED
I I SIDEWALK GRADE
#5 BARS AND SMALLER 1 1/2" JL_ _j ��z
CONCRETE NOT EXPOSED TO EARTH OR WEATHER:
SLABS, WALLS AND JOISTS 3/4"
COLUMN TIES OR SPIRALS AND BEAM STIRRUPS 1 1/2"
GENERAL
STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL, CIVIL, ELECTRICAL, AND
MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT BEFORE PROCEEDING.
CONTRACTOR TO SEE ARCHITECTURAL, CIVIL, ELECTRICAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION
OF PIPE, VENT, DUCT AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS.
CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL
PERMANENT SUPPORT AND STIFFENING ARE INSTALLED.
CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL
ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS
ONLY WILL NOT SATISFY THIS REQUIREMENT.
DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT
SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF
CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL
ENGINEER.
NOTICE BTJ D E C O n D
0 3/2 1 DESIGNED IJ l]
DRAWN � DD
IF THIS BAR DOES
NOT MEASURE 1" JGG SEE OUCH DIM
DRAWING
1 09/21/23 JGG RECORD DRAWINGS THEN NOT TO SCA EIS CHECKED COVER
V SHEFU
NO. DATE BY REVISION
murra,!Iismirth
i
RENTON DOWNTOWN
� UTILITY
IMPROVEMENTS
PROJECT
c
u^
LIGHT POLE FOUNDATION SECTION
SCALE: 1" = V-0"
CTRICAL CONDUIT
ORDINATE W/ LIGHT
E MFR)
1"0 GALV THREADED
)S W/ 18"
BEDMENT INTO
)TING
_/2" x V-0"O ROUND
TE W/ DOUBLE NUTS
D WASHERS
:IRCULAR
> @ 12" OC
45 VERTICAL BARS
NLY SPACED
RECORD DRAWING
THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED
ON CONSTRUCTION RECORDS AND AS -BUILT
INFORMATION PROVIDED BY OTHERS. CG ENGINEERING
HAS NOT VERIFIED THE ACCURACY AND/OR
COMPLETENESS OF THIS INFORMATION.
LUMINAIRE FOUNDATION
PROJECT NO.: 18-2251 I SCALE: AS SHOWN I DATE: SEPTEMBER 2023
R-394975
SHEET
R-41