Loading...
HomeMy WebLinkAboutAB-3949CITY OF RENTON, WASHINGTON DOWNTOWN UTILITY IMPROVEMENT PROJECT 18-2251 JANUARY 2021 H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-GEN-R.dwg G-1 4/25/2023 2:16 PM JGODDARD 24.1s (LMS Tech)S 6TH ST PROJECT LOCATION VICINITY MAP SCALE: 1"=1000'BURNETT AVE SS 2ND ST SHATTUCK AVE SS 134TH S T 405 LAKE WASHINGTON HOUS E R W A Y S S 3RD ST CITY OF RENTON 3949600 UNIVERSITY STREET, SUITE 300 SEATTLE, WA 98101 P 206.462.7030 SW SUNSET BL V D RAINIER AVE SLOGAN AVE S1055 S GRADY WAY RENTON, WA 98057 CITY OF RENTON ARMONDO PAVONE ANGELINA BENEDETTI RANDY CORMAN RYAN MCIRVIN VALERIE O'HALLORAN RUTH PEREZ ED PRINCE KIM-KHANH VAN MAYOR COUNCIL MEMBER COUNCIL MEMBER COUNCIL MEMBER COUNCIL MEMBER COUNCIL MEMBER COUNCIL MEMBER COUNCIL MEMBER CITY OF RENTON OFFICIALS MIKE BENOIT 425-430-7206 MBENOIT@RENTONWA.GOV CITY PROJECT MANAGER TY TADANO 206-462-7030 TY.TADANO@MURRAYSMITH.US DESIGN ENGINEER RECORD DRAWINGS THIS DRAWING IS PROVIDED FOR RECORD PURPOSES ONLY, AND HAS BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS RELATIVE TO REPORTED CONSTRUCTED CONDITIONS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE AS OF OCTOBER 26, 2022, MURRAYSMITH MAKE NO ASSURANCES, STATED OR IMPLIED, AS TO THE ACCURACY OF THIS DRAWING. THOSE RELYING ON THIS RECORD DRAWING FOR ANY PURPOSE ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY. CONTRACT MODIFICATION INFORMATION, FABRICATORS SHOP DRAWINGS AND OTHER PROJECT SUBMITTAL INFORMATION PROVIDED BY THE CONTRACTOR WHICH FURTHER CLARIFY DETAILS OF CONSTRUCTION MAY BE ON FILE. SEE ORIGINAL CONTRACT DRAWINGS FOR ENGINEER'S SEAL AND SIGNATURES. NO.DATEBYREVISIONNOT TO SCALETHEN DRAWING ISNOT MEASURE 1"IF THIS BAR DOESNOTICECHECKEDDRAWNDESIGNEDPROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-GEN-R.dwg G-2 4/25/2023 2:16 PM DAVID.BARKER 24.1s (LMS Tech)SHEET1201NO.DATEBYREVISIONNOT TO SCALETHEN DRAWING ISNOT MEASURE 1"IF THIS BAR DOESNOTICECHECKEDDRAWNDESIGNEDPROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-GEN-R.dwg G-2 4/25/2023 2:16 PM DAVID.BARKER 24.1s (LMS Tech)SHEET1201INDEX OF DRAWINGSGENERAL1G-1TITLE SHEET AND VICINITY MAP2G-2SHEET INDEX3G-3SYMBOLS AND LEGEND4G-4ABBREVIATIONS5G-5GENERAL AND EROSION CONTROL NOTES6G-6SURVEY DATA CONTROL PLAN AND NOTES7G-7PRECONSTRUCTION POTHOLE AND GEOTECHNICAL PLAN AND BLOCK DESIGNATIONS8G-8PRECONSTRUCTION POTHOLE DATA TABLE9G-9TYPICAL EROSION & SEDIMENT CONTROL PLAN AND NOTESDEMOLITION PLANS10D-1 & D-2S 2ND ST UTILITY DEMOLITION PLANS STA A0+00 TO STA A9+6011D-3 & D-4S 2ND ST UTILITY DEMOLITION PLANS STA A9+60 TO STA A19+2012D-5 & D-6S 2ND ST & S 3RD ST UTILITY DEMOLITION PLANS STA A19+20 TO STA A23+40 & STA C0+00 TO STA C4+8013D-7 & D-8S 3RD ST UTILITY DEMOLITION PLANS STA C4+80 TO STA C14+4014D-9 & D-10S 3RD ST UTILITY DEMOLITION PLANS STA C14+40 TO STA C24+0015D-11 & D-12S 3RD ST & PARKING LOT UTILITY DEMOLITION PLANS STA C24+00 TO STA C26+40 & STA E1+20 TO STA E5+0016D-13 & D-14PARKING LOT UTILITY DEMOLITION PLANS STA E5+00 TO STA E11+5117D-15 & D-16SHATTUCK AVE S UTILITY DEMOLITION PLANS STA F0+00 TO STA F9+6018D-17 & D-18SHATTUCK AVE S UTILITY DEMOLITION PLANS STA F9+60 TO STA F16+0019D-19 & D-20WHITWORTH AVE S UTILITY DEMOLITION PLANS STA G0+00 TO STA G6+0020D-21MORRIS AVE S UTILITY DEMOLITION PLANS STA H0+00 TO STA H6+0021D-24S 2ND ST UTILITY DEMOLITION PLAN STA K0+00 TO STA K4+0022D-25 & D-26MILL AVE S UTILITY DEMOLITION PLANS STA L0+00 TO STA L9+60SCH A: STORM DRAIN IMPROVEMENTS23SD-3S 2ND ST STORM PLAN & PROFILE STA A9+40 TO STA A14+0024SD-4S 2ND ST STORM PLAN & PROFILE STA A14+00 TO STA A16+4025SD-7S 3RD ST STORM PLAN & PROFILE STA C4+80 TO STA C9+6026SD-8S 3RD ST STORM PLAN & PROFILE STA C9+60 TO STA C14+4027SD-9S 3RD ST STORM PLAN & PROFILE STA C14+40 TO STA C18+8028SD-10S 3RD ST STORM PLAN & PROFILE STA C18+80 TO STA C22+8029SD-15SHATTUCK AVE S STORM PLAN & PROFILE STA F0+00 TO STA F5+6030SD-16SHATTUCK AVE S STORM PLAN & PROFILE STA F5+60 TO F10+4031SD-17SHATTUCK AVE S STORM PLAN & PROFILE STA F10+40 TO F15+0032SD-18SHATTUCK AVE S STORM PLAN & PROFILE STA F15+00 TO F17+0033SD-19WHITWORTH AVE S STORM PLAN & PROFILE STA G0+00 TO G3+2034SD-20WHITWORTH AVE S STORM PLAN & PROFILE STA G3+20 TO G6+0035SD-21MORRIS AVE S STORM PLAN & PROFILE STA H3+20 TO H6+0036SD-24S 2ND ST STORM PLAN & PROFILE STA K2+80 TO K4+0037SD-25MILL AVE S STORM PLAN & PROFILE STA L0+00 TO STA L4+8038SD-26MILL AVE S STORM PLAN & PROFILE STA L4+80 TO STA L9+0039SD-40LATERAL DRAINAGE PROFILES - 140SD-41LATERAL DRAINAGE PROFILES - 241SD-42LATERAL DRAINAGE PROFILES - 342SD-43LATERAL DRAINAGE PROFILES - 443SD-44LATERAL DRAINAGE PROFILES - 544SD-45LATERAL DRAINAGE PROFILES - 645SD-50STRUCTURAL NOTES46SD-51STRUCTURAL SITE PLAN47SD-52BOX CULVERT ACCESS PLAN48SD-53BOX CULVERT ACCESS DETAILS49SD-54BOX CULVERT PENETRATION SUPPORT DETAILSSCH B: SANITARY SEWER IMPROVEMENTS50SS-1S 2ND ST SEWER PLAN & PROFILE STA A0+00 TO STA A4+8051SS-2S 2ND ST SEWER PLAN & PROFILE STA A4+80 TO STA A9+6052SS-3S 2ND ST SEWER PLAN & PROFILE STA A9+60 TO STA A14+0053SS-4S 2ND ST SEWER PLAN & PROFILE STA A14+00 TO STA A18+8054SS-5S 2ND ST SEWER PLAN & PROFILE STA A19+20 TO STA A23+4055SS-6S 3RD ST SEWER PLAN & PROFILE STA C0+00 TO STA C4+8056SS-7S 3RD ST SEWER PLAN & PROFILE STA C4+80 TO STA C9+6057SS-8S 3RD ST SEWER PLAN & PROFILE STA C9+60 TO STA C14+4058SS-9S 3RD ST SEWER PLAN & PROFILE STA C14+40 TO STA C18+8059SS-10S 3RD ST SEWER PLAN & PROFILE STA C18+80 TO STA C23+6060SS-11S 3RD ST SEWER PLAN & PROFILE STA C23+60 TO STA C26+1561SS-12PARKING LOT EASEMENT SEWER PLAN & PROFILE STA E1+20 TO STA E5+0062SS-13PARKING LOT EASEMENT SEWER PLAN & PROFILE STA E5+00 TO STA E8+0063SS-14PARKING LOT EASEMENT SEWER PLAN & PROFILES STA E8+00 TO STA E11+6064SS-15SHATTUCK AVE S SEWER PLAN & PROFILE STA F0+00 TO STA F5+6065SS-16SHATTUCK AVE S SEWER PLAN & PROFILE STA F5+60 TO F6+8066SS-19WHITWORTH AVE S SEWER PLAN & PROFILE STA G0+00 TO G3+2067SS-20WHITWORTH AVE S SEWER PLAN & PROFILE STA G3+20 TO G6+0068SS-21MORRIS AVE S SEWER PLAN & PROFILE STA H0+00 TO STA H5+8069SS-22BURNETT AVE S SEWER PLAN & PROFILE STA J0+00 TO STA J1+0070SS-24S 2ND ST SEWER PLAN & PROFILE STA K0+00 TO K4+2071SS-25MILL AVE S SEWER PLAN & PROFILE STA L0+00 TO STA L4+8072SS-26MILL AVE S SEWER PLAN & PROFILE STA L4+80 TO STA L9+0073SS-27SIDE SEWER SEWER PLAN & PROFILE STA N0+00 TO STA N4+0074SS-28RAINIER AVE S SEWER PLAN & PROFILE STA B0+00 TO STA B3+2075SS-40KING COUNTY CONNECTION DETAIL S 2ND ST & BURNETT AVE S76SS-41KING COUNTY CONNECTION DETAIL S 3RD ST & BURNETT AVE S77SS-42MISCELLANEOUS SEWER DETAILSSCH C: WATER IMPROVEMENTS78W-1S 2ND ST WATER PLAN & PROFILE STA A0+00 TO STA A4+8079W-2S 2ND ST WATER PLAN & PROFILE STA A4+80 TO STA A9+6080W-3S 2ND ST WATER PLAN & PROFILE STA A9+60 TO STA A14+4081W-15SHATTUCK AVE S WATER PLAN & PROFILE STA F0+00 TO STA F4+8082W-16SHATTUCK AVE S WATER PLAN & PROFILE STA F4+80 TO F10+6083W-19WHITWORTH AVE S WATER PLAN & PROFILE STA G0+00 TO G3+2084W-20WHITWORTH AVE S WATER PLAN & PROFILE STA G3+20 TO G6+0085W-25MILL AVE S WATER PLAN & PROFILE STA L0+00 TO STA L4+8086W-26MILL AVE S WATER PLAN & PROFILE STA L4+80 TO STA L9+0087W-29LAKE AVE S WATER PLAN & PROFILE STA Q0+00 TO STA Q2+0088W-30RENTON HIGH SCHOOL WATER PLAN & PROFILE STA S0+00 TO STA S1+0089W-31SMITHERS AVE S WATER PLAN & PROFILE STA R0+00 TO STA R1+0090W-40WATER CONNECTION DETAILS - 191W-41WATER CONNECTION DETAILS - 292W-42WATER CONNECTION DETAILS - 393W-43WATER CONNECTION DETAILS - 494W-44POLYPIG PLAN AND TEMPORARY THRUST BLOCKINGCATHODIC PROTECTION95CP-1CATHODIC PROTECTION - 196CP-2CATHODIC PROTECTION - 2ROADWAY RESTORATION PLANS97R-1 & R-2S 2ND ST ROADWAY RESTORATION PLANS STA A0+00 TO STA A9+6098R-3 & R-4S 2ND ST ROADWAY RESTORATION PLANS STA A9+60 TO STA A19+2099R-5 & R-6S 2ND ST & S 3RD ST ROADWAY RESTORATION PLANS STA A19+20 TO STA A23+40 & STA C0+00 TO STA C4+80100R-7 & R-8S 3RD ST ROADWAY RESTORATION PLANS STA C4+80 TO STA C14+40101R-9 & R-10S 3RD ST ROADWAY RESTORATION PLANS STA C14+40 TO STA C24+00102R-11 & R-12S 3RD ST & PARKING LOT ROADWAY RESTORATION PLANS STA C24+00 TO STA C26+40 & STA E1+20 TO STA E5+00103R-13 & R-14PARKING LOT ROADWAY RESTORATION PLANS STA E5+00 TO STA E11+00104R-15 & R-16SHATTUCK AVE S ROADWAY RESTORATION PLANS STA F0+00 TO STA F9+60105R-17 & R-18SHATTUCK AVE S ROADWAY RESTORATION PLANS STA F9+60 TO STA F16+80106R-19 & R-20WHITWORTH AVE S ROADWAY RESTORATION PLANS STA G0+00 TO STA G6+00107R-21MORRIS AVE S ROADWAY RESTORATION PLANS STA H0+00 TO STA H6+00108R-24S 2ND ST ROADWAY RESTORATION PLANS STA K0+00 TO STA K5+60109R-25 & R-26MILL AVE S ROADWAY RESTORATION PLANS STA L0+00 TO STA L9+00110R-29 & R-30LAKE AVE S & SMITHERS AVE S RESTORATION PLANS STA Q0+00 TO STA Q2+00 & STA R0+00 TO STA R2+00111R-31CURB RAMP DETAILS - 1112R-32CURB RAMP DETAILS - 2113R-33CURB RAMP DETAILS - 3114R-34CURB RAMP DETAILS - 4115R-35CURB RAMP DETAILS - 5116R-36CURB RAMP DETAILS - 6117R-37CURB RAMP DETAILS - 7118R-38CURB RAMP DETAILS - 8119R-39CURB RAMP DETAILS - 9120R-40RESTORATION AND TRENCH DETAILS121R-41LUMINAIRE FOUNDATIONNOTES:1.SHEET NUMBER IS BASED ON ALIGNMENT ANDSTATION. IT IS CONSISTENT ACROSS UTILITYSETS SO THAT THE EXTENTS SHOWN IN A GIVENSHEET NUMBER FOR ONE UTILITY MATCH THOSESHOWN ON THE SAME SHEET NUMBER FOR THEOTHER UTILITIES. SEE SHEET G-6 FOR SHEETPLAN.2.SHEET NUMBERS ARE OMITTED WHEN THERE ISNO UTILITY WORK IN THAT AREA OF THE PROJECT(I.E. W-3 IS FOLLOWED BY W-15 BECAUSE THEREARE NO WATER IMPROVEMENTS ON SHEETS 4THROUGH 14). UTILITY IMPROVEMENTS ON SHEET23 WERE REMOVED FROM THE PROJECT, THUSSHEET 23 IS OMITTED FROM ALL SHEET SETS.3.DETAIL SHEETS ARE AT THE END OF THEUTILITY SETS BEGINNING WITH SHEET NUMBER40.18-2251G-2of121RENTON DOWNTOWNUTILITYIMPROVEMENTSPROJECTJanuary 2021AS SHOWN110/26/2022JJMRECORD DRAWINGRECORDDRAWINGSSEE NOTE ONCOVER SHEETSHEET INDEX2JJMBAWTTT NO.DATEBYREVISIONNOT TO SCALETHEN DRAWING ISNOT MEASURE 1"IF THIS BAR DOESNOTICECHECKEDDRAWNDESIGNEDPROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-GEN-R.dwg G-3 4/25/2023 2:16 PM DAVID.BARKER 24.1s (LMS Tech)SHEET1201NO.DATEBYREVISIONNOT TO SCALETHEN DRAWING ISNOT MEASURE 1"IF THIS BAR DOESNOTICECHECKEDDRAWNDESIGNEDPROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-GEN-R.dwg G-3 4/25/2023 2:16 PM DAVID.BARKER 24.1s (LMS Tech)SHEET1201VALVE8"SDCHAIN LINK FENCESIDEWALKBLOW-OFF ASSEMBLYTREE DECIDUOUSFIRE HYDRANT ASSEMBLYPULL BOX/JUNCTION BOXTYPE 1 CATCH BASINLIGHT POSTBENCHMARKSIGNWATER METERCLEAN-OUTGUY WIREREDUCERUTILITY POLESANITARY SEWER MANHOLEPROPOSEDSTRUCTURE OR FACILITYEDGE OF PAVEMENT/ACTREE/BUSH LINESANITARY SEWER LINEDRAINAGE DITCHEASEMENT/PROPERTY LINERETAINING WALLCURBGUARDRAILBARBWIRE FENCECENTERLINESTORM DRAIN8"SD8"SSTELEPHONE/TELEMETRYLEGENDGASWATERLINE10"WEXISTING4"G12" DI WS/W8"SSABANDON PIPEEDGE OF GRAVELTREE CONIFEROUSRIGHT-OF-WAYTEMPORARY SILT FENCESHEET FROM WHICHDETAIL IS TAKEN *SHEET WHERE SECTIONIS SHOWN *SECTION AND DETAIL DESIGNATIONSSECTION DESIGNATIONSDETAIL DESIGNATIONS22SCALE:DETAIL2ASCALE:SECTION2A* NOTE: IF PLAN AND SECTION FOR DETAIL CALL-OUT AND DETAIL ARE SHOWN ON THESAME DRAWING, DRAWING NUMBER IS REPLACED WITH A DASH.SECTION LETTERDESIGNATIONSHEET FROM WHICHSECTION IS TAKEN *SECTION LETTERDESIGNATIONDETAILNUMBERFITTINGPROPOSEDEXISTINGTYPE 2 CATCH BASINOVERHEAD ELECTRICITYCLEARING LIMITSCONSTRUCTION FENCEPOLYPIG ASSEMBLYCOUPLINGPOTHOLE18-2251G-3of121RENTON DOWNTOWNUTILITYIMPROVEMENTSPROJECTJanuary 2021AS SHOWN110/26/2022JJMRECORD DRAWINGRECORDDRAWINGSSEE NOTE ONCOVER SHEETSYMBOLS AND LEGEND3JJMBAWTTTGEOTECHNICAL BORINGMONITORING WELLTREE PROTECTION FENCETHRUST BLOCKCATHODIC PROTECTION TEST STATIONTSECOLOGY BLOCKANODE NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-GEN-R.dwg G-4 4/25/2023 2:16 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-GEN-R.dwg G-4 4/25/2023 2:16 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 @ AT AASHTO AMERICAN ASSOCIATION OF STATE HIGHWAY & TRANSPORTATION OFFICIALS AB ANCHOR BOLT ABAN (D) ABANDON (ED) ABV ABOVE AC ASBESTOS CEMENT ACP ASPHALTIC CONCRETE PAVING ADA AMERICANS WITH DISABILITIES ACT ADJ ADJUSTABLE ADJC ADJACENT ADPTR ADAPTER AE ANALYZING ELEMENT AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AFG ACTUAL CUBIC FEET PERMIT AHR ANCHOR AIT ANALYZING INDICATION TRANSMITTER AL ALUMINUM ALT ALTERNATE ANSI AMERICAN NATIONAL STANDARDS INSTITUTE APPROX APPROXIMATE APPVD APPROVED APWA AMERICAN PUBLIC WORKS ASSOCIATION ARCH ARCHITECTURAL ARV AIR RELEASE VALVE ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS ASSN ASSOCIATION ASSY ASSEMBLY ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS ATM ATMOSPHERE AUTO AUTOMATIC AUX AUXILIARY AVE AVENUE AVG AVERAGE AWWA AMERICAN WATER WORKS ASSOCIATION BETW BETWEEN BFD BACKFLOW PREVENTION DEVICE BFILL BACK FILL BFV BUTTERFLY VALVE BIO BIOLOGICAL BKGD BACKGROUND BLDG BUILDING BLK BLOCK BLVD BOULEVARD BM BENCHMARK BMP BEST MANAGEMENT PRACTICE BO BLOWOFF BOC BACK OF CURB BOW BOTTOM OF WALL BR BRINE BS BOTH SIDES BSMT BASEMENT BV BALL VALVE BVCS BEGIN VERTICAL CURVE STATION BVCE BEGIN VERTICAL CURVE ELEVATION BW BOTTOM OF WALL BWD BACKWASH DRAIN BWS BACKWASH SUPPLY C TO C CENTER TO CENTER CARV COMBINATION AIR RELEASE VALVE CB CATCH BASIN CCP CONCRETE CYLINDER PIPE CCW COUNTER CLOCKWISE CDF CONTROLLED DENSITY FILL CHAN CHANNEL CHFR CHAMFER CHKV CHECK VALVE CIP CAST IRON PIPE CIPC CAST IN PLACE CONCRETE CISP CAST IRON SOIL PIPE CJ CONSTRUCTION JOINT CL CENTERLINE CLJ CONTROL JOINT CLR CLEAR CMP CORRUGATED METAL PIPE CMU CONCRETE MASONRY UNIT CO CLEANOUT COL COLUMN COMB COMBINATION CONC CONCRETE CONN CONNECTION CONST CONSTRUCTION CONT CONTINUOUS / CONTINUATION CONTR CONTRACT (OR) COORD COORDINATE COP COPPER COR CITY OF RENTON CORP CORPORATION CORR CORRUGATED CP CONTROL POINT CPLG COUPLING CR CRUSHED ROCK CS COMBINED SEWER CSBC CRUSHED SURFACING BASE COURSE CSP CONCRETE SEWER PIPE CSTC CRUSHED SURFACING TOP COURSE CT COURT CTR CENTER CU CUBIC CV CONTROL VALVE CW CLOCKWISE / COLD WATER CY CUBIC YARDS D DRAIN DEFL DEFLECTION DET DETAIL DI DUCTILE IRON DIA DIAMETER DIM DIMENSION DIR DIRECTION DIST DISTANCE DIV DIVISION DN DOWN DOE DEPARTMENT OF ECOLOGY DR DRIVE/ DRAIN DS DOWNSPOUT DWG DRAWING DWL DOWEL DWV DRAIN WASTE AND VENT DWY DRIVEWAY E EAST EA EACH EC ENUSTON CONTROL ECC ECCENTRIC EL ELEVATION ELB ELBOW ELEC ELECTRICAL ENCL ENCLOSURE EOP EDGE OF PAVEMENT EQL EQUAL EQUIP EQUIPMENT ESC EROSION SEDIMENT CONTROL EUH ELECTRIC UNIT HEATER EW EACH WAY EVCS END VERTICAL CURVE STATION EVCE END VERTICAL CURVE ELEVATION EXC EXCAVATE EXIST EXISTING EXIST GR EXISTING GRADE EXP EXPANSION EXP BT EXPANSION BOLT EXP JT EXPANSION JOINT EXT EXTERIOR F FAHRENHEIT FA FOUL AIR FAB FABRICATE FCA FLANGE COUPLING ADAPTER FCO FLOOR CLEANOUT FD FLOOR DRAIN FDN FOUNDATION FE FLOW ELEMENT FEXT FIRE EXTINGUISHER FIT FLOW INDICATING TRANSMITTER FF FINISH FLOOR FG FINISHED GRADE FGL FIBERGLASS FH FIRE HYDRANT FIN GR FINISHED GRADE FITG FITTING FLEX FLEXIBLE FLG FLANGE FLR FLOOR FM FORCE MAIN FO FIBER OPTIC FOC FACE OF CONCRETE FPM FEET PER MINUTE FPS FEET PER SECOND FRP FIBERGLASS REINFORCED PLASTIC FS FLOW SWITCH/ FIRE STATION FT FEET / FOOT FTG FOOTING FUT FUTURE FXTR FIXTURE G GAS GA GAUGE GAL GALLON GALV GALVANIZED GB GRADE BREAK GI GALVANIZED IRON GIP GALVANIZED IRON PIPE GIS GEOGRAPHIC INFORMATION SYSTEM GL GLASS GR GRADE GR LN GRADE LINE GRTG GRATING GS GROUND SURFACE GV GATE VALVE GRVL GRAVEL HAZ HAZARDOUS HB HOSE BIBB HD HUB DRAIN HDPE HIGH DENSITY POLYETHYLENE HDR HEADER HDWE HARDWARE HGR HANGER HGT HEIGHT HMA HOT MIX ASPHALT HNDRL HAND RAIL HOA HAND-OFF-AUTO HOR HAND-OFF-REMOTE HORIZ HORIZONTAL HP HIGH PRESSURE / HORSEPOWER HPT HIGH POINT HYD HYDRANT I&C INSTRUMENTATION & CONTROL ID INSIDE DIAMETER IE INVERT ELEVATION IMPVT IMPROVEMENT IN INCH INCC INCLUDE (D) (ING) INSTL INSTALLATION / INSTALL INTER INTERCEPTOR INTR INTERIOR INV INVERT JT JOINT JUNC JUNCTION KVA KILOVOLT AMPERE KW KILOWATT LAT LATITUDE LB POUND LF LINEAR FOOT LIN LINEAL LN LANE LOC LOCATION LONG LONGITUDINAL LP LOW PRESSURE/ LOW POINT LPT LOW POINT LRG LARGE LS LONG SLEEVE / LUMP SUM LT LEFT LTF LENGTH TO FIT LVC LIMITS OF VERTICAL CURVE LVL LEVEL LWL LOW WATER LINE MAN MANUAL MATL MATERIAL MAX MAXIMUM MCC MOTOR CONTROL CENTER MCP MASTER CONTROL PANEL MECH MECHANICAL MET METAL MFR MANUFACTURER MGD MILLION GALLONS PER DAY MGMT MANAGEMENT MH MANHOLE MIN MINIMUM MISC MISCELLANEOUS MJ MECHANICAL JOINT MO MASONRY OPENING MON MONUMENT MOT MOTOR N NORTH NA NOT APPLICABLE NC NORMALLY CLOSED NIC NOT IN CONTRACT NO/NO. NORMALLY OPEN/NUMBER NOM NOMINAL NORM NORMAL NPW NON POTABLE WATER NRS NON-RISING STEM NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OF OVERFLOW, OUTSIDE FACE OHP OVER HEAD POWER OHWM ORDINARY HIGH WATER MARK OPNG OPENING OPP OPPOSITE ORIG ORIGINAL OVHD OVERHEAD P&ID PROCESS AND INSTRUMENTATION DIAGRAM PE PLAIN END PERF PERFORATED PERM PERMANENT PERP PERPENDICULAR PG PRESSURE GAGE PL PROPERTY LINE / PLATE / PLASTIC P-LAM PLASTIC LAMINATE PLBG PLUMBING PNL PANEL POLY POLYETHYLENE PP POLYPROPYLENE PRCST PRECAST PREP PREPARATION PRESS PRESSURE PROP PROPERTY/ PROPOSED PRV PRESSURE REDUCING VALVE PSIG POUNDS PER SQUARE INCH GAGE PSL PIPE SLEEVE PSPT PIPE SUPPORT PV PLUG VALVE PVC POLYVINYL CHLORIDE PVI POINT VERTICAL INTERSECTION PVMT PAVEMENT PW POTABLE WATER PWR POWER PZ PRESSURE ZONE QTY QUANTITY RAD RADIUS RC REINFORCED CONCRETE RCP REINFORCED CONCRETE PIPE RD ROAD, ROOF DRAIN RDCR REDUCER REF REFERENCE REINF REINFORCE (D) (ING) (MENT) REQ'D REQUIRED RESTR RESTRAINED RET RETAINING RFCA RESTRAINED FLANGE COUPLING ADAPTER RJ RESTRAINED JOINT ROW RIGHT-OF-WAY RPBP REDUCED PRESSURE BACKFLOW PREVENTION DEVICE RST REINFORCING STEEL RT RIGHT RW RAW WATER R/W RIGHT-OF-WAY S SOUTH SALV SALVAGE SAN SANITARY SCFM STANDARD CUBIC FEET PER MINUTE SCHED SCHEDULE SD STORM DRAIN SDL SADDLE SDR STANDARD DIMENSION RATIO SECT SECTION SHT SHEET SIM SIMILAR SLP/SL/S SLOPE SLV SLEEVE SPEC (S) SPECIFICATION (S) SPG SPACING SPL SPOOL SQ SQUARE SQ FT SQUARE FOOT SQ IN SQUARE INCH SQ YD SQUARE YARD SS SANITARY SEWER SS MH SANITARY MANHOLE SST STAINLESS STEEL ST STREET STA STATION STD STANDARD STL STEEL S/W SIDEWALK T TANGENT TB THRUST BLOCK TC TOP OF CONCRETE / TOP OF CURB TEL TELEPHONE TEMP TEMPERATURE / TEMPORARY THK THICK THRD THREAD (ED) THRU THROUGH TOW TOP OF WALL TP TEST PIT / TOP OF PAVEMENT / TURNING POINT TPZ TREE PROTECTION ZONE TRANS TRANSITION TW TOP OF WALL / TREATED WATER TYP TYPICAL UIC UNDERGROUND INJECTION CONTROL UG UNDERGROUND UGP UNDERGROUND POWER UN UNION UON UNLESS OTHERWISE NOTED USGS UNITED STATES GEOLOGIC SURVEY V VENT / VOLT VAC VACUUM VB VACUUM BREAKER VBOX VALVE BOX VC VERTICAL CURVE VERT VERTICAL VOL VOLUME VTPAV VERTICAL TURBINE PUMP AIR VALVE VTR VENT THROUGH ROOF W WATER/WEST W/ WITH W/O WITHOUT WM WATER METER WMN WATER MAIN WS WATER STOP / WELDED STEEL / WATER SERVICE/ WATER SURFACE WSDOT WASHINGTON STATE DEPARTMENT OF TRANSPORTATION WTRT WATERTIGHT WWF WELDED WIRE FABRIC 18-2251 G-4 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET ABBREVIATIONS 4 JJM BAW TTT NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-GEN-R.dwg G-5 4/25/2023 2:16 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-GEN-R.dwg G-5 4/25/2023 2:16 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRECONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF RENTON. A MINIMUM OF FIVE (5) WORKING DAYS NOTICE IS REQUIRED FOR SCHEDULING. 2. ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION. 3. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 (NAVD 88), AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 (NAD 83/91) UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 4. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR’S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION AND ELEVATION SO AS TO AVOID DAMAGE OR DISTURBANCE. THE CONTRACTOR SHALL POTHOLE AS NEEDED TO CONFIRM THE LOCATION, DEPTH, SIZE, MATERIAL, AND CONFIGURATION OF EXISTING UTILITIES. FOR UTILITY LOCATES CALL 48-HOUR LOCATORS 800-424-5555. 5. TWENTY-FOUR (24) HOURS NOTICE WILL BE REQUIRED PRIOR TO STARTING CONSTRUCTION. 6. IT SHALL BE THE CONTRACTOR’S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACT. ANY WORK WITHIN THE TRAVELED RIGHT OF WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVE BY THE PUBLIC WORKS DEPARTMENT, TRANSPORTATION SYSTEMS DIVISION. THE PLAN SHALL BE CONSISTENT WITH THE PROVISIONS FOUND IN THE STATE OF WASHINGTON MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) FOR STREETS AND HIGHWAYS AND WSDOT STANDARD PLANS. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-07-23 TRAFFIC CONTROL SHALL APPLY. 8. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE LIMITED TO 7:00 AM TO 6:00 PM ON WEEKDAYS SUBJECT TO THE RESTRICTIONS DETAILED IN THE SPECIFICATIONS UNLESS OTHERWISE APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT AT 425-430-7301. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED TWENTY-FOUR (24) HOURS IN ADVANCE OF ANY WORK IN THE RIGHT OF WAY. 9. AN APPROVED TRAFFIC CONTROL PLAN IS REQUIRED TO BE SUBMITTED AT THE PRE-CONSTRUCTION CONFERENCE. 10. INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON. IT SHALL BE THE CONTRACTOR’S RESPONSIBILITY TO NOTIFY DEVELOPMENT SERVICES TWENTY-FOUR (24) HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. THE CONTRACTOR, AS WELL AS THE ENGINEERS, SHALL KEEP AS-BUILT DRAWINGS. 11.ALL STRUCTURES, LOTS, SWALES, DITCHES, CURBS, SPEED BUMPS, FENCES, WALLS, MAILBOXES, SIGNS, POLES, GUY WIRES, PIPING, AND UTILITIES DISTURBED DURING CONSTRUCTION TO BE RESTORED TO EXISTING CONDITIONS UNLESS OTHERWISE SPECIFIED. SUCH REPAIR SHALL BE CONSIDERED INCIDENTAL. 12.DESIGN AND IMPLEMENTATION OF SHORING AND DEWATERING SYSTEMS IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS. A DEWATERING PLAN AND A SHORING SYSTEM PLAN SHALL BE SUBMITTED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. 13.THE CONTRACTOR IS HEREBY ADVISED THAT CONTAMINATED SOIL AND GROUNDWATER HAS BEEN ENCOUNTERED IN THE PROJECT AREA WHICH MUST BE HANDLED AND DISPOSED OF IN COMPLIANCE WITH APPLICABLE REGULATIONS AND AS SPECIFIED IN THE SPECIAL PROVISIONS. A CONTAMINATED SOIL AND WATER MANAGEMENT PLAN SHALL BE SUBMITTED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. 14.THE CONTRACTOR IS REQUIRED TO PERFORM SETTLEMENT MONITORING ON STRUCTURES AND UTILITIES DURING CONSTRUCTION IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS. SETTLEMENT MONITORING RESULTS SHALL BE REPORTED TO THE ENGINEER IN A TIMELY FASHION AS DESCRIBED IN THE SPECIFICATIONS. 15.THE CONTRACTOR SHALL PROTECT AND SUPPORT AS SPECIFIED ANY AND ALL UTILITIES THAT MAY BE IMPACTED BY THE WORK, INCLUDING BUT NOT LIMITED TO THOSE SHOW IN THE PLANS. GENERAL NOTES: 1.ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM), RENTON MUNICIPAL CODE (RMC), AND THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA). IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT TO CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THE PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO THE CITY. 2.APPROVAL OF THE ROAD, GRADING, PARKING, BUILDING, AND DRAINAGE PLAN DOES NOT CONSTITUTE AS APPROVAL OF ANY OTHER CONSTRUCTION (E.G. WATER, SEWER, GAS, ELECTRICAL, ETC.). PLANS FOR STRUCTURES SUCH AS BRIDGES, VAULTS, AND RETAINING WALLS REQUIRE A SEPARATE REVIEW AND APPROVAL BY THE CITY PRIOR TO CONSTRUCTION. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE COORDINATION FOLLOWED BY WRITTEN APPROVAL FROM THE CITY. 3.OPEN CUTTING OF EXISTING ROADWAYS FOR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY AND NOTED ON THESE APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATION STANDARDS. 4.ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TO THE START OF CONSTRUCTION. WHERE SHOWN ON THE PLANS OR WHERE DIRECTED BY THE CITY, THE EXISTING MANHOLES, CATCH BASINS, OR INLETS SHALL BE ADJUSTED TO THE GRADE AS STAKED. CONTRACTOR SHALL LOCATE CATCH BASIN GRATES AT THE FACE OF CURB AND SHALL VERIFY INSTALLATION LOCATIONS PRIOR TO CONSTRUCTION. 5.ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING AND BACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLAN 220.00, 220.10, AND 220.20. 6.ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL BE FITTED WITH DUCTILE IRON, BOLT-LOCKING LIDS PER THE CITY STANDARD PLAN 204.00, 204.10, 204..20, 204.30, AND 204.50. STRUCTURES SHALL HAVE: - RECTANGULAR OR ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND OUTSIDE OF THE ROADWAY. - ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND LOCATED WITHIN THE ROADWAY, BUT OUTSIDE OF THE CURB/GUTTER LINE. - ROUND, SOLID LIDS DISPLAYING THE CITY LOGO WHEN WITHIN THE PUBLIC RIGHT-OF-WAY OR IN AN EASEMENT TO THE CITY. PRIVATE STRUCTURE LIDS OUTSIDE PUBLIC RIGHT-OF-WAY AND EASEMENTS TO THE CITY SHALL NOT DISPLAY THE CITY LOGO. 7.ALL STORM SYSTEM EXTENSIONS SHALL BE STAKED FOR LINE AND GRADE BY A SURVEYOR LICENSED IN WASHINGTON STATE, AND CUT SHEETS SHALL BE PROVIDED TO THE CITY PRIOR TO CONSTRUCTION. 8.ALL NEWLY-INSTALLED AND NEWLY-REHABILITATED (PUBLIC AND PRIVATE) STORM CONVEYANCE SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE CCTV ACCORDING TO THE CITY STANDARD PLAN 266.00. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY PRIOR TO RECEIVING APPROVAL TO INSTALL PROJECT CURBS, GUTTERS AND/OR PAVEMENT. 9.ALL STORM SYSTEMS AND CONNECTIONS TO EXISTING MAINS SHALL BE TESTED IN ACCORDANCE WITH SECTION 7-04.3(1) OF THE WSDOT STANDARD SPECIFICATIONS AND IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY. STORM DRAIN STUBS SHALL BE TESTED FOR ACCEPTANCE AT THE SAME TIME THE MAIN STORM IS TESTED. 10.FOR ALL DISTURBED PREVIOUS AREAS (COMPACTED, GRADED, LANDSCAPED, ETC.) OF THE DEVELOPMENT SITE, TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL EITHER STOCKPILE AND REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR AMEND THE SOIL WITH COMPOST IN ACCORDANCE WITH STANDARD PLAN 264.00. 11.PLACEMENT OF SURFACE APPURTENANCES (CATCH BASIN/MANHOLE LIDS, CLEANOUTS, INLETS, ETC.) IN THE STREET TRAVEL LANE WHEEL PATH, INTERSECTIONS OF STREET TRAVEL LANES, BIKE LANES, SIDEWALKS, AND CROSSWALKS SHALL BE AVOIDED WHENEVER POSSIBLE. ANY SURFACE APPURTENANCE PLACED IN A SIDEWALK OR CROSSWALK SHALL BE FITTED WITH A NON-SLIP OR NON-SKID LID PER ADA REQUIREMENTS. 12.MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4.2.1.A2 OF THE RENTON SWDM. 13.THE LOCATION OF DIRECT CONNECTIONS OF EXISTING STORM DRAIN LATERALS TO THE EXISTING STORM DRAIN PIPE SHOWN ARE BASED ON CCTV VIDEO AND ARE APPROXIMATE. FOR ALL SUCH DIRECT CONNECTIONS SHOWN AND FOR ALL SUCH DIRECT CONNECTIONS WHICH ARE NOT SHOWN BUT ENCOUNTERED DURING CONSTRUCTION, CONTRACTOR SHALL CONTACT CITY ENGINEER TO VERIFY IF THE EXISTING STORM DRAIN LATERAL IS ACTIVE. ADDITIONAL FITTING AND/OR STRUCTURE INSTALLATION TO RECONNECT THE EXISTING STORM DRAIN LATERAL (IF NEEDED) SHALL BE APPROVED BY THE ENGINEER. 14.NEW CATCH BASINS SHALL HAVE RECTANGULAR FRAME PER COR STD PLAN 204.00 AND RECTANGULAR VANED GRATE PER COR STD PLAN 204.20 UNLESS NOTED OTHERWISE ON THE PLANS AND PER THE FOLLOWING: ·STORM ROUND FRAME AND COVER PER COR STD PLAN 204.50 WITH CONVERSION RISER PER COR STD PLAN 200.40. 17.NEW SDMH SHALL HAVE ROUND FRAME AND COVER PER COR STD PLAN 204.50 UNLESS NOTED OTHERWISE ON THE PLANS AND PER THE FOLLOWING: ·RECTANGULAR FRAME PER COR STD PLAN 204.00 AND RECTANGULAR VANED GRATE PER COR STD PLAN 204.20. SURFACE WATER DRAINAGE NOTES: 1.ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON PUBLIC WORKS STANDARD SPECIFICATIONS AND SPECIAL PROVISIONS AND WSDOT / APWA STANDARD SPECIFICATIONS, LATEST EDITION AS AMENDED BY THE CITY OF RENTON. A SET OF CITY APPROVED PLANS SHALL BE KEPT AT THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. A PRE -CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR AND OR DEVELOPER SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS PRIOR TO CONSTRUCTION. 2.ALL EXISTING UTILITIES SHALL REMAIN IN SERVICE DURING CONSTRUCTION UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL CALL 1- 800-424- 5555 TO VERIFY UTILITY LOCATIONS BEFORE BEGINNING EXCAVATION. 3.ALL MATERIALS USED FOR THE CONSTRUCTION OF WATER SYSTEM IMPROVEMENTS SHALL BE NEW AND UNDAMAGED, AND CATALOG CUTS" FOR ALL MATERIALS SHALL BE APPROVED IN WRITING BY THE CITY OF RENTON PRIOR TO BRINGING ANY MATERIALS ON- SITE. 4.ALL WATER MAIN PIPE MATERIALS SHALL BE CEMENT LINED DUCTILE IRON PIPE, THICKNESS CLASS 52 PER AWWA C 151 AND C 104. CAST IRON OR DUCTILE IRON PIPE FITTINGS SHALL BE CLASS 250 AS PER ANSI/ AWWA C110/ A21. 10- 82. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE WRAPPED WITH 8 -MIL BLACK, TUBE -TYPE, POLYETHYLENE PLASTIC PER AWWA C105 STANDARDS. ALL DUCTILE IRON PIPES, FITTINGS, AND VALVES SHALL BE RESTRAINED-JOINT PIPE. 5.MINIMUM COVER FROM TOP OF WATER MAINS TO FINISHED GRADE SHALL BE 36 INCHES FOR PIPE DIAMETER OF 10 -INCH OR LESS AND 48 INCHES FOR PIPE DIAMETER OF 12 -INCH AND LARGER. MAXIMUM COVER FOR ALL WATER MAINS SHALL BE 60 INCHES. ANY DEVIATIONS MUST BE APPROVED BY THE CITY OF RENTON PRIOR TO CONSTRUCTION. WHERE UTILITY CONFLICTS OCCUR, THE PROFILE OF THE WATER MAIN SHALL BE ADJUSTED AS NECESSARY TO CLEAR CONFLICTS AND TO PROVIDE MINIMUM COVER. PIPE DEFLECTION SHALL NOT EXCEED ONE- HALF OF PIPE MANUFACTURER' S SPECIFICATION FOR SIZE OF PIPE USED. ALL TRENCH BACKFILL SHALL BE COMPACTED TO 95 PERCENT MAXIMUM DRY DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST METHOD ( MDD) IN ROADWAYS, ROADWAY SHOULDERS, ROADWAY PRISM AND DRIVEWAYS, AND 85 PERCENT MDD IN UNPAVED AREAS. ALL PIPE ZONE COMPACTION SHALL BE 95 MDD. 6.CONCRETE BLOCKING FOR WATER MAINS SHALL BE DESIGNED, INSTALLED AND POURED IN PLACE IN ACCORDANCE WITH CITY OF RENTON STANDARD DETAILS AND SPECIFICATIONS AND SHALL BE INSTALLED AT ALL VERTICAL AND HORIZONTAL BENDS, FITTINGS AND BASE OF HYDRANTS. MEGA -LUGS ( OR SIMILAR PRODUCT) MAY BE REQUIRED ON ALL MECHANICAL JOINTS IN ADDITION TO CONCRETE BLOCKING. 7.ALL NEW WATER MAIN PIPES AND FITTINGS SHALL HAVE A FOAM PIPE PIG RUN THROUGH THEM PRIOR TO BEING FLUSHED, DISINFECTED, AND TESTED. CLEANING, PRESSURE AND PURITY TESTING SHALL BE DONE IN THE PRESENCE OF AND UNDER THE SUPERVISION OF A CITY OF RENTON UTILITY INSPECTOR. THE CONTRACTOR SHALL SUPPLY, INSTALL AND REMOVE PLUGS, CORPORATION STOPS, BLOW -OFF ASSEMBLIES, AND THRUST RESTRAINT / BLOCKING FOR TESTING AND PURITY ACCEPTANCE. NO CONNECTION SHALL BE MADE BETWEEN THE NEW MAIN OR BETWEEN THE NEW WET -TAP VALVE TO AN EXISTING MAIN UNTIL THE NEW PIPING HAS BEEN FOAM -PIGGED, DISINFECTED, FLUSHED, AND PASSED BOTH PRESSURE AND PURITY TESTING. 8.NEW WATER MAINS INCLUDING SERVICE LATERALS SHALL BE TESTED AT A STATIC PRESSURE OF 150 PSI ABOVE WORKING PRESSURE WITH A MINIMUM OF 225 PSI TEST PRESSURE FOR 120 MINUTES WITH A MAXIMUM OF 5 PSI PRESSURE DROP DURING THE ENTIRE TEST PERIOD. UPON SATISFACTORY COMPLETION OF THE PRESSURE TEST, THE LINE SHALL BE DISINFECTED, FLUSHED, AND THEN WATER SAMPLES SHALL BE TAKEN FOR PURITY TESTING BY THE PUBLIC WORKS INSPECTOR. 9.THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON WATER UTILITY AND MAINTENANCE DEPARTMENTS AT LEAST 10 WORKING DAYS PRIOR TO MAKING CONNECTIONS TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL EXPOSE THE EXISTING WATER MAIN AND FITTINGS AT THE CONNECTION POINT BEFORE ORDERING THE NECESSARY ADAPTORS AND FITTINGS REQUIRED FOR THE FINAL CONNECTION. THE CONTRACTOR SHALL EXCAVATE, REMOVE ALL SURFACE MATERIALS, AND PROVIDE SHORING AND ALL MATERIALS REQUIRED FOR THE CITY OF RENTON TO PERFORM THE CONNECTION TO THE EXISTING WATER SYSTEM. THE CONTRACTOR SHALL PROVIDE AND INSTALL BACKFILL, CONCRETE BLOCKING, AND COMPLETE SURFACE RESTORATION. 10.TEMPORARY WATER SERVICE CONNECTIONS AND RECOMMENDED POLYPIGGING AND DISINFECTION PLAN AS SHOWN IN THIS PLAN SET ARE SCHEMATIC AND REPRESENTS THE MINIMUM WORK ANTICIPATED. THE CONTRACTOR IS REQUIRED TO SUBMIT A FULL TEMPORARY SERVICE AND POLYPIGGING/DISINFECTION PLAN AND PROVIDE TEMPORARY THRUST RESTRAINT CALCULATIONS UP TO THE MAXIMUM TEST PRESSURE. ANY VARIATION OR ADDITION TO TEMPORARY SERVICE PLAN OR POLYPIGGING AND DISINFECTION PLAN SHALL HAVE WRITTEN APPROVAL FROM THE CITY OF RENTON WATER DEPARTMENT. 11.ANTICIPATED TEMPORARY WATER SERVICES, CUT AND CAP LOCATIONS, VALVE AND HYDRANT REMOVAL, AND PIPE ABANDONMENT/REMOVAL INFORMATION IS AVAILABLE IN THE DEMOLITION SHEETS. 12.AT UTILITY CROSSINGS MAINTAIN MINIMUM VERTICAL SEPARATION OF 18" FROM ALL OTHER UTILITIES UNLESS OTHERWISE NOTED, MEASURED WALL-TO-WALL. 13.TEMPORARY 2-INCH WATER SERVICE SHALL BE POLYETHYLENE (PE) PIPE OR APPROVED EQUAL WITH THRUST RESTRAINT AND SHALL BE INSTALLED IN TRENCH WITH 24" OF COVER OVER PIPE. WORK TO INCLUDE ALL CONNECTIONS TO EXISTING WATER SERVICE LINES UPSTREAM OF EXISTING WATER METERS AND ALL REQUIRED FITTINGS. DISINFECTION AND SATISFACTORY PURITY SAMPLES SHALL BE OBTAINED FROM NEW TEMPORARY 2-INCH WATER LINE BEFORE CONNECTION TO EXISTING WATER SERVICES. WATER UTILITY NOTES: 1.THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS-BUILT DRAWING OF THE SANITARY SEWER SYSTEM, WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR. AS-BUILT DRAWINGS SHALL INCLUDE NORTHING AND EASTING OF ALL CLEANOUTS. 2.PIPE BEDDING SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED. 3.ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. 4.SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D3034, SDR 35, OR AWWA C900 OR C905, UNLESS OTHERWISE APPROVED BY THE WASTEWATER UTILITY. 5.IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCHES AND MAXIMUM 12 INCHES ABOVE FINISHED GRADE OR MUST HAVE MINIMUM 2' DIAMETER CONCRETE RING POURED AT GRADE. IN PAVED AREA, COVER MUST SLOPE TO MATCH PAVING. 6. MH LADDERS AND CONES SHALL BE ORIENTED SUCH THAT THE LADDER ENDS ON A CHANNEL BENCH AND, TO THE GREATEST EXTENT PRACTICAL, THE COVER IS OUTSIDE THE WHEELPATH OF THE TRAVELED WAY. 7.LOCATIONS OF SIDE SEWERS SHOWN ARE APPROXIMATE AND MAY NOT REFLECT ACTUAL LOCATIONS. 8.AT UTILITY CROSSINGS MAINTAIN MINIMUM TYPICAL VERTICAL SEPARATION OF 18" FROM WATER AND 12" FROM OTHER UTILITIES, MEASURED WALL TO WALL, UNLESS OTHERWISE SHOWN ON THE PLANS. NOTIFY ENGINEER IF TYPICAL VERTICAL SEPARATION CAN NOT BE MET. 6-INCH ETHAFOAM PAD MAY BE USED IF APPROVED BY THE ENGINEER SANITARY SEWER NOTES: 18-2251 G-5 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET GENERAL AND EROSION CONTROL NOTES 5 JJM BAW TTT 1.CHANNELIZATION MARKERS SHALL BE REPLACED IN PLACE PER STANDARD PLAN 109 OR AS DIRECTED BY THE ENGINEER. MISCELLANEOUS NON-STANDARD TRAFFIC AND PARKING LINES SHALL BE REPLACED WITH THERMOPLASTIC PAINT. SHUR-CURB TRAFFIC MARKERS SHALL BE REMOVED AND REPLACED. 2.TEMPORARY CHANNELIZATION MARKINGS SHALL BE PER WSDOT STANDARD PLAN K-70.20 OR AS DIRECTED BY THE ENGINEER. 3.ALL SIGNS SHALL BE REPLACED IN PLACE, INSTALLED AS SHOWN ON THE PLANS, OR INSTALLED AS DIRECTED BY THE ENGINEER PER STANDARD PLAN 129. 4.ALL LANDSCAPING IMPACTED BY THE WORK SHALL BE REPLACED IN ACCORDANCE WITH THE SPECIFICATIONS. 5.FOR STREETS WITH PAVEMENT OVERLAY, PROVIDE CROWNED ROADWAY SECTION WITH PEAK IN THE CENTER OF THE STREET AND SLOPE OF 1.5% TO 2.0% OR AS DIRECTED BY THE ENGINEER. RESTORATION NOTES: S 3RD ST SHATTUCK AVE SS 4TH ST S 3RD ST MORRIS AVE SLOGAN AVE SBURNETT AVE SWILLIAMS AVE SS 2ND ST WELLS AVE SHOUS E R W A Y SRAINIER AVE SRAINIER AVE SS 2ND STLAKE AVE SS 4TH PL SMITHERS AVE SS 3RD ST S 4TH ST MAIN AVE SFO DUCT FO DUCT FO DUCT SPU P R O P E R T Y BRO N S O N W A Y S ALIGNMENT CORNER STA A7+34 N:178640.79 E:1298975.55 ALIGNMENT CORNER STA A9+68 N:178598.24 E:1299205.04 ALIGNMENT CORNER STA E5+94 N:178548.47 E:1298661.12 ALIGNMENT CORNER STA E8+30 N:178542.01 E:1298897.55 ALIGNMENT CORNER STA E9+95 N:178512.29 E:1299059.94 ALIGNMENT CORNER STA L0+74 N:178862.29 E:1301757.63 A23+40 A0+00 B3+20B0+00E11 + 5 1 E0+0 0 E7+00 E8+00 E9+00 E10 + 0 0 E11+ 0 0 F16+80F1+00G6+00G0+00G6+00H6+60H0+00K4+00K0+00 L9+00L 0 + 0 0 L9+00N4+01N0+00N4+00Q2+00Q0+00C26+15C0+00 R0+83R2+00J0+00J1+00SPU RIGHT-OF-WAY S 2ND ST BP: 0+00.00Mid: 0+77.89PT: 1+55.78PI: 12+75.68PI: 15+91.73PI: 19+07.77PI: 22+23.75PI: 25+34.73EP: 26+14.85L=2614.85' R=955.00' Δ=9°20'46" L=320.00' R=581.46' Δ=22°23'10" BP: 0+00.00 PC: 0+68.42 Mid: 1+82.01 PT: 2+ 9 5 . 6 0 EP: 3+ 2 0 . 0 0 SPU PROPERTY WHITWORTH AVE SSW SUNSET BLVD MILL AVE SSHATTUCK AVE SALIGNMENT CORNER STA E2+58 N:178234.56 E:1298540.40 ALIGNMENT LOCATION TABLE START STA A0+00 B0+00 C0+00 E0+00 F1+00 G0+00 H0+00 K0+00 L0+00 N0+00 NORTHING N178662.72 N178363.78 N178066.25 N178117.71 N178598.19 N178593.70 N178589.14 N178548.86 N178913.58 N179039.76 EASTING E1298241.40 E1298223.43 E1297920.59 E1298310.08' E1299208.27 E1299524.29 E1299840.23 E1301424.86 E1301704.71 E1298489.26 END STA A23+40 B3+20 C26+15 E11+51 F16+80 G6+00 H6+60 K4+00 L9+00 N4+00 NORTHING N178572.52 N178048.70 N178013.44 N178461.48 N177018.62 N177993.87 N177929.01 N178538.43 N178036.28 N178639.82 EASTING E1300576.45 E1298255.65 E1300534.22 E1299206.67 E1299171.69 E1299510.33 E1299824.99 E1301824.72 E1301735.70 E1298477.62 NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SRV CTL-PH-DATA-TESC-R.dwg G-6 4/25/2023 3:59 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SRV CTL-PH-DATA-TESC-R.dwg G-6 4/25/2023 3:59 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 18-2251 G-6 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET SURVEY DATA CONTROL PLAN AND NOTES 6 JJM TTT PLAN SCALE: NTS SHEET INDEX: A STATIONING: SHEETS 1-5 B STATIONING: RAINIER AVE (NO SHEETS) C STATIONING: SHEETS 6-11 E STATIONING: SHEETS 12-14 F STATIONING: SHEETS 15-18 G STATIONING: SHEETS 19-20 H STATIONING: SHEET 21 J STATIONING: SHEETS 22-23 K STATIONING: SHEET 24 L STATIONING: SHEETS 25-26 SS-1, W-1 SS-2, W-2 SS-3, SD-3, W-3 SS-4, SD-4 SS-5 SD-24, SS-24 SS-11 SS-10, SD-10 SS-9, SD-9 SS-8, SD-8 SS-7, SD-7SS-6 SS-13SS-14 SS-1 2 SS-15, SD-15,SS-16, SD-16,SD-17SD-18SS-19, SD-19,SS-21SS-22SS-25, W-25,SS-26, W-26,SS-20, SD-20,SS-21,SD-21SD-24 1.FIELD SURVEY: KPG, NOVEMBER, 2017 - FEBRUARY, 2018; SEPTEMBER 2018 - DECEMBER 2018; FEBRUARY 2019, MAY 2019, JANUARY 2020, APRIL 2020 2. ALL SURVEY MONUMENTS SHALL BE PROTECTED OR REMOVED AND REPLACED PER CITY STANDARD DETAIL H031 AS REQUIRED FOR CONSTRUCTION. NOTES WASHINGTON STATE PLANE COORDINATE SYSTEM, NORTH ZONE, NAD 83/91 PER CITY OF RENTON CONTROL STATIONS 205, 884, 1140, AND 1896. HORIZONTAL DATUM NAVD 88, PER CITY OF RENTON CONTROL STATIONS 2133 AND 2128. VERTICAL DATUM SS-27W-29W-30LEGEND: ALIGNMENT SHEET FRAME BAWSS-28W-31SD-25SD-26W-20 W-19W-15W-16 S 3RD ST SHATTUCK AVE SS 4TH ST S 3RD ST MORRIS AVE SLOGAN AVE SBURNETT AVE SWILLIAMS AVE SS 2ND ST WELLS AVE SHOUS E R W A Y SRAINIER AVE SRAINIER AVE SS 2ND STLAKE AVE SS 4TH PL SMITHERS AVE SS 3RD ST S 4TH ST MAIN AVE SFO DUCT FO DUCT FO DUCT SPU P R O P E R T Y BRO N S O N W AY S SPU RIGHT-OF-WAY S 2ND ST SPU PROPERTY WHITWORTH AVE SSW SUNSET BLVD MILL AVE SSHATTUCK AVE SNO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SRV CTL-PH-DATA-TESC-R.dwg G-7 4/25/2023 3:59 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SRV CTL-PH-DATA-TESC-R.dwg G-7 4/25/2023 3:59 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 18-2251 G-7 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET PRECONSTRUCTION POTHOLE AND GEOTECHNICAL PLAN AND BLOCK DESIGNATIONS 7 JJM TTT PLAN SCALE: NTS 1 28 6 2 3 4A 4B 5 25 1110 21 19 15 16 17 18 987 20 27 22 BAW # KEY: BLOCK NUMBER DESIGNATION PRE-CONSTRUCTION POTHOLE MONITORING WELL GEOTECHNICAL INVESTIGATION BORING 1. BLOCK NUMBER DESIGNATIONS ARE PROVIDED FOR THE CONTRACTOR'S CONVENIENCE IN PLANNING AND SCHEDULING CONSTRUCTION ACTIVITIES SUCH AS TRAFFIC CONTROL, DEWATERING, SHORING, ETC. 2. SEE SHEET G-8 FOR POTHOLE TABLE 3. EXISTING MONITORING WELLS SHOWN IN THE TABLE ON THIS SHEET SHALL BE DECOMMISSIONED IN ACCORDANCE WITH DOE PROCEDURES AND ASPHALT PATCHED WITH 3-FT SQUARE T-PATCH, FOLLOWED BY A FULL LANE WIDTH GRIND AND OVERLAY MINIMUM OF 6.5-FT LONG, SEE CITY STD DETAIL 110. 4. GEOTECHNICAL INVESTIGATION BORINGS HAVE BEEN PREVIOUSLY DECOMMISSIONED, CONTRACTOR SHALL PATCH WITH 3-FT SQUARE ASPHALT T-PATCH, FOLLOWED BY A FULL LANE WIDTH GRIND AND OVERLAY MINIMUM OF 6.5-FT LONG, SEE CITY STD DETAIL 110. NOTES 24 26 MONITORING WELL DECOMMISSIONING TABLE PROJECT WELL NO.DOE WELL NO. MW-1 BKH-303 KB-1 BJH-958 MW-2 BKH-302 MW-3 BKH-304 MW-4 BKH-301 MW-5 BKH-305 MW-6 BKH-306 MW-8 BKH-307 KB-10 BJH-960 KB-11 BJH-961 KB-14 BJH-959 KB-18 BJH-957 13 12 14 NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SRV CTL-PH-DATA-TESC-R.dwg G-8 4/25/2023 3:59 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SRV CTL-PH-DATA-TESC-R.dwg G-8 4/25/2023 3:59 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 18-2251 G-8 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET PRECONSTRUCTION POTHOLE DATA TABLE 8 JJM TTT Plan/Profile ID NO. Existing Utility Utility Material Utility Size Approx. Depth to Top of Exist Utility (IN) Approx. Depth to Bottom of Exist Utility (IN) 1 T Plastic (2) 2"33 36 2 UGP Plastic (2) 1" - (1) 2" - (1) 2"11 33 3 T Plastic (4) 2" - 1(3")31 41 4 UGP, COM, G Steel 3/4"46 48 5 WS, G Poly / Cooper (1) 1/2" - (1) 1/2"36 37 6 G Steel 2"51 53 7 G, GS Steel (1) 4" - (1) 1"33 41 8 UGP, COM Plastic (2) 4"26 31 9 G Poly 2"41 43 10 G Poly 4"54 59 11 GS Poly 2"38 40 12 UGP Poly 2"26 28 13 T Plastic 3"48 59 14 UGP Plastic (3) 2" - (2) 2"32 36 15 GS Steel 5/8"16 17 16 G Steel/Poly Insert 2"21 23 17 UGP, T, G Plastic / Steel (3) 3" (2) 4" (6) 2" - 2"16 64 18 UGP, T Plastic (8) 4" - (1) 1"18 36 19 UGP Poly 4"25 29 20 UGP, T Plastic/ Concrete Duct (2) 4" - (1) 2"24 59 21 T Duct (2) 4"34 86 22 G Poly 2"27 29 23 UGP, T Plastic (1) 1" - (1) 2" - (2) 4"34 39 24 UGP, T Plastic (1) 6" - (2) 4" - (3) 3" - (3) 2"25 44 25 W DIP 8"29 37 26 W DIP 8"31 39 27 G Poly 2"32 34 28 UGP, T Poly 2"31 33 Plan/Profile ID NO. Existing Utility Utility Material Utility Size Approx. Depth to Top of Exist Utility (IN) Approx. Depth to Bottom of Exist Utility (IN) 29 UGP, T, G Plastic/Poly (1) 8" - (3) 2" - (2) 2" - (4) 4" (1) 1/2" 20 60 30 W Steel 12"44 57 31 G Poly 1"58 60 32 G, UGP Steel 6"34 40 33 G Steel 2"44 46 34 G, T Poly 2"57 59 35 SS PVC 8"47 55 36 SD PVC 8"36 44 37 W DIP 66"31 97 38 WS,G Poly 1"47 48 39 SD Plastic 6"37 44 40 G Steel 4"32 41 41 T Plastic/ Concrete (2) 2" - (1) 10"39 54 42 UGP, T Plastic (8) 4"28 41 43 T Plastic (2) 2" - (2) 4" - (1) 6"33 44 44 UGP, T Plastic/ Concrete Duct (1) 4" - (3) 3"20 51 45 T Plastic 6"44 51 46 G Steel 4"42 47 47 UGP Poly (3) 2"38 40 48 W Steel 6"24 31 49 UGP Plastic (1) 1" - (1) 2"23 40 50 UGP Plastic (1) 2" - (2) 4"57 63 51 WS DIP 8"40 48 52 W DIP 52"28 84 53 T Plastic (1) 4" - (3) 2"30 35 54 UGP Plastic (4) 4" - (1) 2"26 34 55 T Plastic (3) 4" - (4) 3"33 41 56 UGP Plastic (1) 3" - (2) 2"28 32 57 COM Plastic (2) 4" - (2) 2"24 48 58 UGP Steel 2"20 23 Plan/Profile ID NO. Existing Utility Utility Material Utility Size Approx. Depth to Top of Exist Utility (IN) Approx. Depth to Bottom of Exist Utility (IN) 59 W Steel 66"37 105 60 W Steel 52"31 85 61 W DIP 8"38 47 62 G Steel 4"48 52 63 UGP Steel 4"48 52 64 G Plastic (1) 3" - (3) 2"28 33 65 T PVC 2"39 42 66 UGP, FO Plastic (1) 1" - (1) 2"25 30 67 G Plastic (1) 1" - (1) 2"25 29 68 T Plastic (3) 4"23 29 69 T Concrete 13" x 24"48 61 70 UGP Steel 2"39 41 71 W DIP 66"90 156 72 T PVC 2"39 42 73 W Steel 30"80 110 74 P Steel 2"57"59" 75 G Plastic Duct 44"60" 76 T Plastic Duct 44"53" 77 T Concrete Duct 42"50 78 P Plastic (2) 4"30"36" 79 G Poly 5/8"34"35" 80 COM Steel 6"35"41" 81 W Steel 66"38"104" 82 G Poly 6"48 54 83 G Steel 4"56 60 84 G Steel 2"37 39 85 G Poly 2"43 45 86 G Poly 2"41 43 87 P PVC 4"36 40 88 P PVC 4"30 34 89 P PVC 3x4"31 39 90 G Steel 2"51 53 BAW ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••32 33 33 33 34 33 34 34 33 34 34 33 34 333333 3333 32 NO PARKING FIRE LANE34 CRPL #3 66" STL CRPL #3 66" STL CRPL#3 66" STL CRPL#3 66" STL FO DUCT FO DUCT FO DUCT STA A13+15, 4.3' LT 1-SDMH #5.5 8"C900 SDSTA A12+98, 47.1' RT 1-MH (224)12"DI W12"DI W12"DI W 12"DI W12"DI W TS TS TS TS TSG0+00A10+00 A11+00 A12+00 A13+00 A14+00 A15+00 F1+008" SDR 35 SS 8" C900 SS8" C900 SS8" SDR 35 SS2"PVC CONDUIT 2"PVC CONDUIT 18-2251 G-9 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET TYPICAL EROSION & SEDIMENT CONTROL PLAN AND NOTES JJM BAW TTT 9NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-ESC-R.dwg G-9 4/25/2023 4:24 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 S 2ND ST SHATTUCK AVE S TYPICAL LOCAL EROSION CONTROL PLAN SCALE: 1"=20' INLET PROTECTION TREE PROTECTION FENCE LEGEND EROSION CONTROL NOTES 1.ALL REQUIRED SEDIMENTATION/EROSION CONTROL FACILITIES MUST BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AND/OR CONSTRUCTION TO ENSURE THAT SEDIMENT LADEN WATER DOES NOT ENTER THE NATURAL DRAINAGE SYSTEM. ALL EROSION AND SEDIMENT CONTROL FACILITIES SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARING AND/OR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON-SITE EROSION HAS PASSED. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT AND ADDITIONS TO EROSION/SEDIMENTATION CONTROL SYSTEMS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 2.THE EROSION AND SEDIMENTATION CONTROL BMPs DEPICTED ON THESE DRAWINGS ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE CONTRACTOR SHALL ANTICIPATE THAT MORE EROSION AND SEDIMENTATION CONTROL BMPs WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE CONTRACTOR TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL BMPs, OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM. 3.BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY, CATCH BASIN INSERTS PER CITY STANDARD PLAN 216.30 SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE INLET WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. ALL CATCH BASIN INSERTS SHALL BE PERIODICALLY INSPECTED AND REPLACED AS NECESSARY TO ENSURE FULLY FUNCTIONING CONDITION. 4.WHERE STRAW MULCH FOR TEMPORARY EROSION CONTROL IS REQUIRED, IT SHALL BE APPLIED AT A MINIMUM THICKNESS OF 2 TO 3 INCHES. 5.KEEP PUBLIC AND PRIVATE ROADWAYS/PARKING LOTS, SIDEWALKS, AND TRAILS FREE OF DEBRIS AND SEDIMENT. 6. ANY AREAS OF EXPOSED SOILS THAT WILL NO BE DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCTOBER 1ST THROUGH APRIL 30TH) OR SEVEN DAYS DURING THE DRY SEASON (MAY 1ST THROUGH SEPTEMBER 30TH) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVES ESC COVER METHODS IN CONFORMANCE WITH APPENDIX D OF THE RENTON SWDM. NOTE: 1. THIS IS A TYPICAL EXAMPLE OF THE IMPLEMENTATION OF EROSION AND SEDIMENT CONTROL BEST MANAGEMENT PRACTICES. CONTRACTOR RESPONSIBLE TO USE DETAILS PROVIDED IN ACCORDANCE WITH APPLICABLE STANDARDS. TYPICAL SEWER MAIN WORK AREA SECTION VIEW TREE PROTECTION NOTES: 1. SEE SPECIFICATIONS FOR ADDITIONAL TREE PROTECTION REQUIREMENTS. 2. EXCAVATED ROOTS 2" OR LARGER SHALL BE PROTECTED IN PLACE OR CLEANLY CUT BACK TO THE SOIL LINE AS APPROVED BY THE ENGINEER AND IN ACCORDANCE WITH THE SPECIFICATIONS. WRAP WITH WETTED BURLAP UNTIL BACKFILLED AND COVERED WITH NEW SOIL 3. NO PRUNING SHALL BE PERFORMED EXCEPT BY APPROVED ARBORIST. ONCE INSTALLED, TPZ FENCING SHALL BE INSPECTED AND APPROVED PRIOR TO ANY MAJOR EXCAVATION OR DIRT WORK. 4. NO EQUIPMENT SHALL OPERATE INSIDE THE PROTECTIVE FENCING INCLUDING DURING FENCE INSTALLATION AND REMOVAL. 5. NO FOOT TRAFFIC ALLOWED INSIDE TPZ FENCING 6. NO MATERIAL STORAGE ALLOWED INSIDE TPZ FENCING INLET PROTECTION TO BE INSTALLED IN ALL CATCH BASINS IN THE VICINITY OF THE WORK ZONE, SEE RENTON STD PLAN 216.30 TYPICAL STORM DRAIN WORK AREA TREE PROTECTION FENCE TO BE INSTALLED AROUND TREES IN 2ND ST MEDIAN, SEE DETAIL THIS SHEET SCALE: 1/4"=1'-0" TREE PROTECTION - FENCING IN THE TREE PROTECTION ZONE (TPZ)1 -WHITWORTHAVE STYPICAL WATER MAIN WORK AREA TREE PROTECTION FENCE: 6' HT. CHAIN LINK FENCE WITH STEEL POSTS INSTALLED AT 8' O.C. PANELS TO BE COVERED WITH FABRIC OR TARP MATERIAL TO PREVENT DIRT AND DUST FROM ENTERING TPZ MAINTAIN EXISTING GRADE WITH THE TREE PROTECTION FENCE. NO SOIL DISTURBANCE PERMITTED INSIDE TPZ 6'-0"419419321305 400 400 •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••3 8 3 7 3 8 3 7 3 639383637 38 353 5 3 4 36 35 34 35 34 3 3 32 31333231293030 31 3233 3 4 3738434 2 41 40 39 FIRE LANE 35 CRPL#3 66" STL CRPL#1 66" STL CRPL#2 51.5" STL CRPL#3 66" STL CRPL#1 66" STL CRPL#2 51.5" STL CRPL#1 66" STL CRPL#2 51.5" STL CRPL#3 66" STL ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• •••••••••••••••••••••••••••••••••••••••••••••••••••••••• •••• •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• A0+00 A1+00 A2+00 A3+00 A4+00Q0+00Q1+00N3+00N4+00N4+01••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 31 31 31 31 32 32 3 3 32 32 3 2 31 32 32 32 NO PARKING FIRE LAN E NO PARKINGNO PARKING FIRE LANESTOP NO PARKINGNO PARKINGNO PARKING FIRE LANE3 2 3231 CRPL#3 66" STL CRPL#2 51.5" STL CRPL#3 66" STL CRPL#1 66" STL •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• A5+00 A6+00 A7+00 A8+00 A9+00 18-2251 D-1 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 2ND ST UTILITY DEMOLITION PLANS STA A0+00 TO STA A9+60 SEO BAW TTT 10NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-DEMO-R.dwg D-1 4/25/2023 5:36 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 MATCHLINE STA A4+80SEE BELOWRAINIER AVE SLAKE AVE SS 2ND ST MATCHLINE STA A4+80SEE ABOVEMATCHLINE STA A9+60SEE SHEET D-3D-2 3 43 6 7 4 5 3 6 4 6 3 2.ABANDON MH IN PLACE PER CITY STD DET 400.5 3.REMOVE MH OR CB ENTIRELY AND REPLACE AS SHOWN IN PLANS 4.ABANDON PIPE IN PLACE WTIH CONCRETE PLUG 5.REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS 6.REMOVE AND REPLACE FIRE HYDRANT, EXISTING HYDRANT TO BE DELIVERED TO THE CITY IN ACCORDANCE WITH THE SPECS. TO BE DONE AT FINAL CONNECTION TO NEW WATERLINE 7.REMOVE CONCRETE BOLLARDS 8.CUT AND CAP WATER MAIN IN ACCORDANCE WITH SPECS 9.ABANDON MONITORING WELL IN ACCORDANCE WITH SPECS TEMPORARY THRUST BLOCKING DETAIL ON W-44 VALVE TO BE REMOVED IN ACCORDANCE WITH SPECS PLUG AND ABANDON CB WITH CEMENT BASED GROUT DEMOLITION NOTES 2 3 4 5 6 S 2ND ST 7 LEGEND REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS ABANDON PIPE AND APPURTENANCES IN PLACE WITH CAP OR PLUG AS SPECIFIED FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT 10 10 11 11 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 12 13 14 2" TEMP WATER 12 12 13 13 INSTALL 2" TEMPORARY WATER SERVICE LINE TO WATER METERS TO 200 S 2ND ST PRIOR TO ABANDONMENT OF EXIST 8" W IN S 2ND ST EXIST 2" IRRIGATION METER AND FH TO BE OUT OF SERVICE DURING CONSTRUCTION OF NEW 12" WATER IN S 2ND ST 14 5 INSTALL 2" TEMPORARY WATER SERVICE LINE TO WATER METERS TO 200 S 2ND ST PRIOR TO ABANDONMENT OF EXIST 8" W IN S 2ND ST 2" TEMP WATER 13 2 •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••32 33 33 33 34 33 34 34 33 34 34 33 3333 32 NO PARKING FIRE LANE34 CRPL #3 66" STL CRPL#3 66" STL CRPL#3 66" STL FO DUCT FO DUCT A10+00 A11+00 A12+00 A13+00 A14+00G0+00F1+00••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••33 3 4 34 34 3535 35 36 36 3635 3534 34 333333 CRPL #3 66" STL CRPL #3 66" STL •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••FO DUCT A15+00 A16+00 A17+00 A18+00 A19+00 H0+0018-2251 D-3 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 2ND ST UTILITY DEMOLITION PLANS STA A9+60 TO STA A19+20 SEO BAW TTT 11NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-DEMO-R.dwg D-3 4/25/2023 5:36 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 S 2ND ST MATCHLINE STA A9+60SEE SHEET D-2MATCHLINE STA A14+40SEE BELOWWHITWORTHAVE SSHATTUCKAVE SFOR CONTINUATION SEE SHEET D-19 FOR CONTINUATION SEE SHEET D-15 S 2ND STMATCHLINE STA A14+40SEE ABOVEMATCHLINE STA A19+20SEE SHEET D-5MORRISAVE SFOR CONTINUATON SEE SHEET D-21 D-4 1.ABANDON MH IN PLACE PER CITY STD DET 400.5 2.REMOVE MH OR CB ENTIRELY AND REPLACE AS SHOWN IN PLANS 3.ABANDON PIPE IN PLACE WTIH CONCRETE PLUG 4.REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS CUT AND CAP WATER MAIN IN ACCORDANCE WITH SPECS TEMPORARY THRUST BLOCKING DETAIL ON W-44 VALVE TO BE REMOVED IN ACCORDANCE WITH SPECS PLUG AND ABANDON CB WITH CEMENT BASED GROUT FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT DEMOLITION NOTES 3 13 2 12 6 3 5 15 2 4 4 3 5 3 6 PIPE MAY HAVE BEEN PREVIOUSLY ABANDONED, MH'S WERE NOT PROPERLY ABANDONED PIPE MAY HAVE BEEN PREVIOUSLY ABANDONED, MH'S WERE NOT PROPERLY ABANDONED 15 15 4 4 2 2 2 2 5 3 2 3 4 5 10 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 10 12 13 14 15 14 15 10 13 2" TEMP WATER 12 INSTALL 2" TAP AND 2" TEMPORARY WATER SERVICE LINE AND CONNECT TO 3 EXISTING METERS (1-2" IRRIGATION AND 2-34" DOMESTIC METERS) LEGEND REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS ABANDON PIPE AND APPURTENANCES IN PLACE WITH CAP OR PLUG AS SPECIFIED FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT 13 ADJUST REMOVAL EXTENTS AS REQUIRED TO MAINTAIN 6" CLEARANCE BTWN ABANDONED SEWER AND NEW SD 5 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••37 37 37373737 37 38 3839 39 37 38 373938CRPL #3 66" STL CRPL #3 66" STL CRPL #3 66" STL••••••••••••••••••••••CRPL #3 66" STL A20+00 A21+00 A22+00 A23+00 A23+40J0+00J1+00•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• •••••••••••••••••••••••••••••••• 33 32 34 33 32 31 30 323131••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••C0+00 C1+00 C2+00 C3+00 C4+00B2+00B3+00B3+20E0+0 0 E1+0 0 18-2251 D-5 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 2ND ST AND S 3RD ST UTILITY DEMOLITION PLANS STA A19+20 TO STA A23+40 & STA C0+00 TO STA C4+80 SEO BAW TTT 12NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-DEMO-R.dwg D-5 4/25/2023 5:36 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 S 2ND ST MATCHLINE STA A19+20SEE SHEET D-3LOGAN AVE SBURNETT AVE SS 3RD ST MATCHLINE STA C4+80SEE SHEET D-7RAINIERAVE SSW SUNSET BLV D 165 LF 8" CIPP SSD-6 2.ABANDON MH IN PLACE PER CITY STD DET 400.5 3.REMOVE MH OR CB ENTIRELY AND REPLACE AS SHOWN IN PLANS 4.REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS 5.ABANDON MONITORING WELL IN ACCORDANCE WITH SPECS FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT DEMOLITION NOTES 2 3 5 15 2 3 2 3 3 3 5 3 5 15 2 FOR CONT INUAT IONSEE SH EET D -12 11 11 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 15 15 LEGEND REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS ABANDON PIPE AND APPURTENANCES IN PLACE WITH CAP OR PLUG AS SPECIFIED FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT 11 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••32 32 3131 32 32 32 32 32STOPC5+00 C6+00 C7+00 C8+00 C9+00D3+00D3+05•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••32 31 31 3132 C10+00 C11+00 C12+00 C13+00 C14+00F6+00F7+0018-2251 D-7 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 3RD ST UTILTIY DEMOLITION PLANS STA C4+80 TO STA C14+40 SEO BAW TTT 13NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-DEMO-R.dwg D-7 4/25/2023 5:36 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 S 3RD ST MATCHLINE STA C4+80SEE SHEET D-5, D-6MATCHLINE STA C9+60SEE BELOWFOR CONTINUATION SEE SHEET D-12 SHATTUCKAVE SS 3RD ST MATCHLINE STA C9+60SEE ABOVEMATCHLINE STA C14+40SEE SHEET D-9FOR CONTINUATION SEE SHEET D-15 D-8 3 17 4 4 2 2 3 4 8 4 5 3 2 15 3 5 3 15 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 2.ABANDON MH IN PLACE PER CITY STD DET 400.5 3.REMOVE MH OR CB ENTIRELY AND REPLACE AS SHOWN IN PLANS 4.ABANDON PIPE IN PLACE WTIH CONCRETE PLUG 5.REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS 6.REMOVE FIRE HYDRANT, EXISTING HYDRANT TO BE DELIVERED TO THE CITY IN ACCORDANCE WITH THE SPECS. TO BE DONE AT FINAL CONNECTION OF NEW WATER LINE 7.ABANDON MONITORING WELL IN ACCORDANCE WITH SPECS FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT DEMOLITION NOTES 2 3 4 5 8 11 15 15 3 15 LEGEND REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS ABANDON PIPE AND APPURTENANCES IN PLACE WITH CAP OR PLUG AS SPECIFIED FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT 11 •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••33 33 33 33 34 3433C15+00 C16+00 C17+00 C18+00G5+00G6+00G6+00••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••34 34 35 35 35 3636 3636C19+00 C20+00 C21+00 C22+00 C23+00H5+00H6+00R0+83R1+00R2+00R2+00WHITWORTHAVE S18-2251 D-9 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 3RD ST UTILITY DEMOLITION PLANS STA C14+40 TO STA C24+00 SEO BAW TTT 14NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-DEMO-R.dwg D-9 4/25/2023 5:36 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 S 3RD ST MATCHLINE STA C14+40SEE SHEET D-8MATCHLINE STA C18+80SEE BELOWFOR CONTINUATION SEE SHEET D-20 FOR CONTINUATION SEE SHEET D-21 MORRIS AVE SMATCHLINE STA C118+80SEE ABOVEMATCHLINE STA C23+60SEE SHEET D-11LOGAN AVE SSMITHERSAVE SD-10 3.REMOVE MH OR CB ENTIRELY AND REPLACE AS SHOWN IN PLANS 4.ABANDON PIPE IN PLACE WTIH CONCRETE PLUG 5.REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS REMOVE CONCRETE BOLLARDS 6.REMOVE FIRE HYDRANT, EXISTING HYDRANT TO BE DELIVERED TO THE CITY IN ACCORDANCE WITH THE SPECS. TO BE DONE AT FINAL CONNECTION OF NEW WATER LINE CUT AND CAP WATER MAIN IN ACCORDANCE WITH SPECS 7.ABANDON MONITORING WELL IN ACCORDANCE WITH SPECS TEMPORARY THRUST BLOCKING DETAIL ON W-44 VALVE TO BE REMOVED IN ACCORDANCE WITH SPECS FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT REMOVE TRAFFIC DETECTION LOOP DEMOLITION NOTES 3 4 5 8 3 4 5 34 5 3 3 4 8 3 7 5 11 11 S 3RD ST 11 11 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 15 17 7 13 10 12 17 8 12 10 STA C22+30, 6' LT 1-8" PLUG, RJ 1-TB STA C21+86, 6' LT 1-8" PLUG, RJ 1-TB 13 10 15 3 13 10 LEGEND REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS ABANDON PIPE AND APPURTENANCES IN PLACE WITH CAP OR PLUG AS SPECIFIED FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT EXIST 6" CONC SD LEFT IN SERVICE ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••37 37 38 3839 CRPL # 3 6 6 " S T L CRPL # 2 5 1 . 5 " S T L C24+00 C25+00 C26+00 C26+15J6+00J6+80•••••••••••••••••••••••••••••••••••••••••••••••••••32STOPC6+00D0+00 D1+00 D2+00 D3+00D3+05 E2+00E3+ 0 0 E4+ 0 0 BURNETT AVE S18-2251 D-11 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 3RD ST & PARKING LOT UTILITY DEMOLITION PLANS STA C24+00 TO STA C26+40 & STA E1+20 TO STA E5+00 SEO BAW TTT 15NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-DEMO-R.dwg D-11 4/25/2023 5:36 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 S 3RD ST MATCHLINE STA C23+60SEE SHEET D-9S 3RD STFOR CONTINUATION SEE SHEET D-6 FOR CONTINUATION SEE SHEET D-7 D-12 2.REMOVE MH OR CB ENTIRELY AND REPLACE AS SHOWN IN PLANS 3.REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS 4.ABANDON MONITORING WELL IN ACCORDANCE WITH SPECS FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT DEMOLITION NOTES 3 5 3 5FOR CONTINUATIONSEE SHEET D-13FOR CONTINUATION SEE SHEET D-6 11 11 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 15 153 LEGEND REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS ABANDON PIPE AND APPURTENANCES IN PLACE WITH CAP OR PLUG AS SPECIFIED FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT 15 •••••••••••••••••••••••••••••32 32 31 32 NO PARKINGPARKING FIRE LANEFIRE LANE NO PARKING FIRE LANE NO PARKINGNO PARKING FIRE LANENO PARKING FIRE LANESTOP 3 2 32 CRPL#3 66" STL CRPL#2 51.5" STL CRPL#1 66" STLCRPL#1 66" STL CRPL#2 51.5" STL CRPL#3 66" STL ••••••••••••••••••••••••••••••••••••••••••••••••••••••E5+00E6+00 E7+00Q2+00••••••••••••••••••••••••••••••••••••••••••••••••3 3 32 3232 3 2 31 32 31NO PARKING FIRE LANENO PARKINGNO PARKINGNO PARKING FIRE LANE3 2 3231 32 32CRPL#3 66" STL CRPL # 1 6 6 " S T L CRPL # 2 5 1 . 5 " S T L ••••••••••••••••••••••••••••••••••••••F1+00F2+00E8+00 E9+00 E10+ 0 0 E11+ 0 0 E11 + 5 1 18-2251 D-13 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET PARKING LOT UTILITY DEMOLITION PLANS STA E5+00 TO STA E11+51 SEO BAW TTT 16NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-DEMO-R.dwg D-13 4/25/2023 5:36 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 S 2ND ST MATCHLINE STA E2+80SEE BELOWS 2ND S T MATCHLINE STA E2+80SEE ABOVESHATTUCK AVE SFOR CONTINUATIONSEE SHEET D-2FOR CONTINUATION SEE SHEET D-15 D-14 3.REMOVE MH OR CB ENTIRELY AND REPLACE AS SHOWN IN PLANS 4.ABANDON PIPE IN PLACE WTIH CONCRETE PLUG 5.REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT DEMOLITION NOTES 3 4 5 3 3 3 FOR CONTINUATION SEE SHEET D-12 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 15 5 4 15 5 LEGEND REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS ABANDON PIPE AND APPURTENANCES IN PLACE WITH CAP OR PLUG AS SPECIFIED FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••323333323232 32 32 32 31 3 2 CRPL#2 51.5" STLCRPL#1 66" STLCRPL#3 66" STLCRPL#1 66" STLCRPL#2 51.5" STL•••••••••••••••••••••••A9+00A10+00F1+00 F2+00 F3+00 F4+00 F5+00 E11+00E11+51•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••313131 31 C12+00C13+00F6+00 F7+00 F8+00 F9+00 18-2251 D-15 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET SHATTUCK AVE S UTILITY DEMOLITION PLAN STA F0+00 TO STA F9+60 SEO BAW TTT 17NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-DEMO-R.dwg D-15 4/25/2023 5:36 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1S 2ND STMATCHLINE STA F5+40SEE BELOWSHATTUCK AVE S FOR CONTINUATION SEE SHEET D-2 FOR CONTINUATION SEE SHEET D-2 S 3RD STSHATTUCK AVE S FOR CONTINUATION SEE SHEET D-8 FOR CONTINUATION SEE SHEET D-7 D-16 2.ABANDON MH IN PLACE PER CITY STD DET 400.5 3.REMOVE MH OR CB ENTIRELY AND REPLACE AS SHOWN IN PLANS 4.ABANDON PIPE IN PLACE WTIH CONCRETE PLUG 5.REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS 6.REMOVE AND REPLACE FIRE HYDRANT, EXISTING HYDRANT TO BE DELIVERED TO THE CITY IN ACCORDANCE WITH THE SPECS. TO BE DONE AT FINAL CONNECTION TO NEW WATER LINE CUT AND CAP WATER MAIN IN ACCORDANCE WITH THE SPECS TEMPORARY THRUST BLOCKING DETAIL ON W-44 VALVE TO BE REMOVED IN ACCORDANCE WITH SPECS PLUG AND ABANDON CB WITH CEMENT BASED GROUT FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT DEMOLITION NOTES 2 3 4 5 6 15 3 5 6 3 15 2 3 5 4 4 3 2 3 4 25 5 3 6 MATCHLINE STA F5+40SEE ABOVEMATCHLINE STA F9+60SEE SHEET D-1710 3 10 12" VALVE TO BE REMOVED. INSTALL 12" PLUG (RJ) AND TB TO EXISTING CROSS. 3 10201004060 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 12 13 14 3 14 2" TEMP WATER SERVICE 12 INSTALL 2" TAP AND 2" TEMPORARY WATER SERVICE LINE AND CONNECT TO 3 EXISTING 34" DOMESTIC METERS 14 LEGEND REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS ABANDON PIPE AND APPURTENANCES IN PLACE WITH CAP OR PLUG AS SPECIFIED FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT 13 13 13 13 15 •••••••••••••••••••••••••••••••••••••••••••••••••• 30 30 3030 29 •••••••••••••••••••••••••••••••••••••••••••••••••• •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• F10+00 F11+00 F12+00 F13+00 F14+00 •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 29 29 29 28 28 2 8 •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• • • • ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• F14+00 F15+00 F16+00 F16+80 18-2251 D-17 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET SHATTUCK AVE S UTILITY DEMOLITION PLANS STA F9+60 TO STA F16+00 SEO BAW TTT 18NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-DEMO-R.dwg D-17 4/25/2023 5:36 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 SHATTUCK AVE S MATCHLINE STA F14+00SEE BELOWMATCHLINE STA F14+00SEE ABOVED-18 1.REMOVE MH OR CB ENTIRELY AND REPLACE AS SHOWN IN PLANS 2.REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS 3.ABANDON MONITORING WELL IN ACCORDANCE WITH SPECS 4.PLUG AND ABANDON CB WITH CEMENT BASED GROUT 5.FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT DEMOLITION NOTES 3MATCHLINE STA F9+60SEE SHEET D-16SHATTUCK AVE S 5 5 3 33 11 33 5 11 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 14 15 15 15 14 LEGEND REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS ABANDON PIPE AND APPURTENANCES IN PLACE WITH CAP OR PLUG AS SPECIFIED FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT 11 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••333433 3333 33 33 CRPL #2 51.5" STLCRPL#3 66" STLCRPL#1 66" STL••••••••••••••••••••••••••••••••••••••A12+00A13+00G0+00 G1+00 G2+00 G3+00 ••••••••••••••••••••••••••33333333 33••••••C16+00G4+00 G5+00 G6+00G6+00 18-2251 D-19 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET WHITWORTH AVE S UTILITY DEMOLITION PLANS STA G0+00 TO STA G6+00 SEO BAW TTT 19NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-DEMO-R.dwg D-19 4/25/2023 5:36 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 WHITWORTH AVE S MATCHLINE STA G3+20SEE BELOW2ND STFOR CONTINUATION SEE SHEET D-3 FOR CONTINUATION SEE SHEET D-3 WHITWORTH AVE S MATCHLINE STA G3+20SEE ABOVES 3RD STFOR CONTINUATION SEE SHEET D-9 FOR CONTINUATION SEE SHEET D-9 D-20 1.REMOVE MH OR CB ENTIRELY AND REPLACE AS SHOWN IN PLANS 2.ABANDON PIPE IN PLACE WTIH CONCRETE PLUG 3.REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS 4.REMOVE AND REPLACE FIRE HYDRANT, EXISTING HYDRANT TO BE DELIVERED TO THE CITY IN ACCORDANCE WITH THE SPECS. TO BE DONE AT FINAL CONNECTION TO NEW WATER LINE 5.REMOVE HYDRANT, EXISTING HYDRANT TO BE DELIVERED TO THE CITY IN ACCORDANCE WITH THE SPECS 6.CUT AND CAP WATER MAIN IN ACCORDANCE WITH SPECS 7.ABANDON MONITORING WELL IN ACCORDANCE WITH SPECS 8.TEMPORARY THRUST BLOCKING DETAIL ON W-44 9.VALVE TO BE REMOVED IN ACCORDANCE WITH SPECS DEMOLITION NOTES 3 4 5 6 6 4 5 5 4 3 5 54 8 5 8 10 4 5 3 10 REMOVE 2 EXISTING 8" VALVES AT EXISTING 12"x8" CROSS AND INSTALL 2-8" BLIND FLANGES ON NORTH AND SOUTH SIDE OF CROSS, SEE CONNECTION DET H ON SHT W-41 10 11 APPROXIMATE LOCATION OF KB-14, CONTRACTOR SHALL FIELD LOCATE AND ABANDON MONITORING WELL IN ACCORDANCE WITH SPECS 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 12 13 13 12 11 INSTALL 2" TAP AND 2" TEMPORARY WATER SERVICE LINE AND CONNECT TO 3 EXISTING METERS (1-2" IRRIGATION AND 2-34" DOMESTIC METERS) 11 LEGEND REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS ABANDON PIPE AND APPURTENANCES IN PLACE WITH CAP OR PLUG AS SPECIFIED FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT 2" TEMP WATER SERVICE 2" TEMP WATER SERVICE ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••343 5 35343433 33 3333 CRPL#1 66" STLCRPL#2 51.5" STLCRPL #3 66" STL••••••••••••••••••••••••••••A16+00H0+00 H1+00 H2+00 H3+00 •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••3434 33 3434C19+00H4+00 H5+00 H6+00 H6+60 18-2251 D-21 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET MORRIS AVE S UTILITY DEMOLITION PLANS STA H0+00 TO STA H6+00 SEO BAW TTT 20NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-DEMO-R.dwg D-21 4/25/2023 5:36 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 MORRIS AVE S S 2ND STMORRIS AVE S S 3RD STFOR CONTINUATION SEE SHEET D-9 FOR CONTINUATION SEE SHEET D-10 FOR CONTINUATION SEE SHEET D-4 FOR CONTINUATION SEE SHEET D-4 LOCATION OF EXIST SIDE SEWER IS UNKNOWN, CONTRACTOR TO LOCATE AND ABANDON OR REMOVE AS NECESSARY TO INSTALL STRAIGHT SIDE SEWER TO MAIN AS SHOWN ON SS-21 1.ABANDON MH IN PLACE PER CITY STD DET 400.5 3.REMOVE MH OR CB ENTIRELY AND REPLACE AS SHOWN IN PLANS 4.ABANDON PIPE IN PLACE WTIH CONCRETE PLUG 5.REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT DEMOLITION NOTES 2 3 4 5 2 4 4 5 3 3 3 5 MATCHLINE STA H3+20SEE ABOVEMATCHLINE STA H3+20SEE BELOW2 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 1 15 1 15 LEGEND REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS ABANDON PIPE AND APPURTENANCES IN PLACE WITH CAP OR PLUG AS SPECIFIED FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••444444 45 4545 464544 4444454 646 CRPL#3 66" STLCPPL#3 66" STLCPPL#3 66" STLCPPL#3 66" STL ••••••••••••••••••••••••••••••••K0+00 K1+00 K2+00 K3+00 K4+00 L4+00L4+0018-2251 D-24 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 2ND ST UTILITY DEMOLITION PLANS STA K0+00 TO STA K4+00 SEO BAW TTT 21NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-DEMO-R.dwg D-24 4/25/2023 5:36 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 S 2ND ST MILL AVE S4 3 FOR CONTINUATION SEE SHEET D-25MAIN AVE S2.REMOVE MH OR CB ENTIRELY AND REPLACE AS SHOWN IN PLANS 3.ABANDON PIPE IN PLACE WTIH CONCRETE PLUG 4.REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS 5.REMOVE HYDRANT, EXISTING HYDRANT TO BE DELIVERED TO THE CITY IN ACCORDANCE WITH THE SPECS CUT AND CAP WATER MAIN IN ACCORDANCE WITH SPECS VALVE TO BE REPLACED IN ACCORDANCE WITH SPECS FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT REMOVE WATER VAULT DEMOLITION NOTES 3 4 5 84 5 8 CONTINUATION SEE SHEET D-25 10 20100 40 60 PLAN SCALE: 1"=20' 10 13 15 13 33 13 15 LEGEND REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS ABANDON PIPE AND APPURTENANCES IN PLACE WITH CAP OR PLUG AS SPECIFIED FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT 20 20 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••46 454644 45 4544 4 4 45 46 4 343 CRPL#3 66" STL CPPL#3 66" STLK3+00K4+00L0+00 L1+00 L2+00 L3+00 L4+00 L5+00 L0+00 L1+00 L2+00 L3+00 L4+00 L5+00 •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••5 3 5 2 5 1 5 0 4 9 48 4 747 46 46 46 46 46 45 CRPL#3 66" STLCRPL#3 66" STL CRPL#3 66" STL L5+00 L6+00 L7+00 L8+00 L9+00L9+00L5+00 L6+00 L7+00 L8+00 L9+00L9+00 18-2251 D-25 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET MILL AVE S UTILITY DEMOLITION PLANS STA L0+00 TO STA L9+60 SEO BAW TTT 22NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-DEMO-R.dwg D-25 4/25/2023 5:36 PM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 MILL AVE S S 2ND STFOR CONTINUATION SEE SHEET D-24 MATCHLINE STA L5+00SEE BELOWMILL AVE S HOUSER WAY SMATCHLINE STA L5+00SEE ABOVED-26 3.REMOVE MH OR CB ENTIRELY AND REPLACE AS SHOWN IN PLANS 4.ABANDON PIPE IN PLACE WTIH CONCRETE PLUG 5.REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS 6.REMOVE HYDRANT, EXISTING HYDRANT TO BE DELIVERED TO THE CITY IN ACCORDANCE WITH THE SPECS CUT AND CAP WATER MAIN IN ACCORDANCE WITH SPECS TEMPORARY THRUST BLOCKING DETAIL ON W-44 VALVE TO BE REMOVED IN ACCORDANCE WITH SPECS FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT REMOVE TRAFFIC DETECTION LOOP AS REQUIRED FOR CONSTRUCTION CONTRACTOR TO DETERMINE WHICH SS IS ACTIVE, AND RECONNECT WITH CO, ABANDON OLD SS REMOVE WATER VAULT DEMOLITION NOTES 3 4 5 8 4 5 3 4 84 3 33 10 10 8 10 REMOVE EXIST 6" VALVE AND EXIST 16"x6" REDUCER AT EXIST 24"x16" CROSS AND INSTALL 16" PLUG (RJ) AND TB 10 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 13 15 16 18 316 18 13 13 15 15 LEGEND REMOVE PIPE AND APPURTENANCES ENTIRELY AND REPLACE AS SHOWN IN PLANS ABANDON PIPE AND APPURTENANCES IN PLACE WITH CAP OR PLUG AS SPECIFIED FILL PIPE WITH CEMENT BASED GROUT FOR ABANDONMENT 20 12 13 12 13 20 4 NO METER, NO REMOVAL 1012 ABANDONED VALVE LEFT IN PLACE ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••32 33 33 33 34 33 34 34 33 34 33 3333 32 32 NO PARKING FIRE LANE34 CRPL #3 66" STL CRPL#3 66" STL CRPL#3 66" STL ••••FO DUCT FO DUCT FO DUCT FO DUCT FO DUCT8"DI W12"DI W12"DI W 12"DI WG0+00G1+00A10+00 A11+00 A12+00 A13+00 A14+00 12"DI W TS TS TS TS TS TSG0+00G1+00A10+00 A11+00 A12+00 A13+00 A14+00 8" SDR 35 SS 8" C900 SS8" SDR 35 SS2"PVC CONDUIT A10+00 A11+00 A12+00 A13+00 A14+00 STA A9+52, 19.5' LT 1-48'' SDMH #1 (EXIST) STA A9+51, 23.9' LT 1-CB #1 STA A10+84, 18.1' LT 1-48'' SDMH #3 STA A12+69, 15.1' LT 1-48'' SDMH #5 STA A12+69, 23.1' LT 1-CB #6 STA A9+61, 49.9' RT 1-48'' SDMH #2 STA A9+92, 62.4' RT 1-CB #2 STA A11+11, 48.0' RT 1-CB #4 8" D I S D8"PP SD 12"C900 SD 12"DI S D 15"PP SD 8"DI SD STA A10+84, 23.4' LT 1-CB #3 8" D I S D STA A13+15, 4.3' LT 1-SDMH #5.5 12"PP SD 12"DI SDSTA A11+02, 48.0' RT 1-48" SADDLE SDMH #4 PER COR STD PLANS 201.00 AND 400.6 RIM=32.46 IE(OUT)12"(W)=28.38' 8"DI SD MATCHLINE STA A14+00SEE SHEET SD-4EXIST GR @ ROW CL 15 20 25 30 35 40 45 50 15 20 25 30 35 40 45 50 A9+40 A9+60 A9+80 A10+00 A10+20 A10+40 A10+60 A10+80 A11+00 A11+20 A11+40 A11+60 A11+80 A12+00 A12+20 A12+40 A12+60 A12+80 A13+00 A13+20 A13+40 A13+60 A13+80 A14+00EXIST W(TO BE ABAN/REMOVED)EXIST UGPEXIST UGPEXIST TEXIST SSIE=20.6EXIST TEXIST UGPEXIST SS(TO BE REROUTED ATSTA A13+00 AND REMOVED)PROP 12"WEXIST SSIE=20.6128 LF 15" PP SD @ SLP=0.61% 185 LF 12" C900 SD @ SLP=0.24% 48'' SDMH #3 IE(IN)12"(E)=27.35 IE(IN)8"(S)=30.37 IE(IN)12"(N)=28.15 IE(OUT)15"(W)=27.01 STA A10+84, 18' LT RIM=32.42 47 LF 12" DI SD @ SLP=0.11% 48'' SDMH #1 (EXIST) IE(IN)12"(N)=27.98 IE(IN)15"(E)=26.23 IE(OUT)12"(S)=22.80 IE(OUT)12"(W)=22.87 STA A9+52, 19' LT RIM=31.80 48'' SDMH #5 IE(IN)12"(E)=27.80 IE(IN)12"(S)=30.00 IE(IN)12"(N)=28.32 IE(OUT)12"(W)=27.80 STA A12+69, 15' LT RIM=32.89 23.18 (RECONNECT) 27.50 28.38 32.17 129 LF SLP=0.17% 27.72 28.92 27.97 SDMH #5.5 IE(IN)12"(E)=27.88 IE(OUT)12"(W)=27.85 STA A13+15, 4' LT RIM=33.26 127 LF 12" PP SD @ SLP=0.86%EXIST 12"TEL, SS184 LF 12" PP SD @ SLP=0.38% 29.12 28.53 28.53 PROTECT W/ DENSE FOAM CUSHION PROTECT FO W/ DENSE FOAM CUSHION, REMOVE AND REROUTE SS 32.39 27.50 (PLUG) SLP=0.60% LT 20100 40 60 PLAN SCALE: 1"=20' 18-2251 SD-3 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 2ND ST STORM PLAN & PROFILE STA A9+40 TO STA A14+00 SEO BAW TTT 23NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SD-R.dwg SD-3 11/10/2023 11:47 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE S 2ND ST MATCHLINE STA A14+00SEE SHEET SD-4SHATTUCKAVE S1 11 1111 12 12 9 TYP CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 REMOVE INACTIVE DETECTION LOOP INSTALL CB PER COR STD PLAN 200.00 INSTALL CB PER COR STD PLAN 201.00 CONNECT PIPE TO EXIST DRAINAGE STRUCTURE CONNECT EXIST STORM DRAIN PIPE TO NEW STRUCTURE SEE PROFILE 1 ON SHT SD-40 SEE PROFILE 2 ON SHT SD-40 SEE PROFILE 3 ON SHT SD-40 SEE PROFILE 4 ON SHT SD-40 SEE PROFILE 5 ON SHT SD-40 CONSTRUCTION NOTES: 1 11 12 15 CONTINUATION SEE SHEET SD-15 APPROXIMATE LOCATION OF 66" SPU CRPL TYP CONTINUATION SEE SHEET SD-19 11 CB #7, SEE SHT SD-40 CB #5, SEE SHT SD-40 SDMH #4, SEE SHT SD-40 15 TYP OF 2 WHITWORTHAVE S12 19 9 431AT&T CRITICAL FIBER OPTIC, PROTECT IN PLACE PER 1-07.17 20 21 22 23 11 12 321 305 400 419 20 21 19 PROTECT EXIST FRANCHISE UTIL IN PLACE 23 23 22 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS 8" STORM RECONNECTED TO EXIST SDMH #62637 LATERAL CONNECTED AT 7'-3" DEEP FOUND STORM LATERAL, REROUTED TO SDMH #2, 6'-8" DEEP 13 13 EXIST TYPE 2 LEFT IN PLACE FOUND PREVIOUSLY UNKNOWN LUMEN FO DUCT 13 13 REROUTE EXIST 12"VCP SS TO EXIST SSMH 62818 ASREQ'D FOR SD INSTALL (ABANDONED IN PLACE) PROVIDE TEMPORARY SUPPORT AND PROTECT EXIST FO DUCT DURING CONSTRUCTION 400 15 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••34 33 3 4 34 34 3535 3534 34 333333 CRPL #3 66" STL CRPL #3 66" STL •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••H0+00H1+00A14+00 A15+00 A16+00 A17+00H0+00H1+00A14+00 A15+00 A16+00 A17+00 8" C900 SS 8" C900 SS 8" SDR 35 SS2"PVC CONDUIT 2"PVC CONDUIT A14+00 A15+00 A16+00 A17+00H0+00H1+00STA A14+42, 22.9' LT 1-CB #8 STA A14+42, 3.1' LT 1-48'' SDMH #6 STA A15+87, 4.4' LT 1-48'' SDMH #7 STA A15+88, 23.2' LT 1-CB #10 STA A14+39, 47.9' RT 1-CB #9 STA A15+84, 61.0' RT 1-CB #11 STA A16+22, 63.3' RT 1-CB #12 STA A15+85, 47.7' RT 1-48'' SDMH #8 8"C900 SD 8"DI SD8"DI SD12"PP SD 8"DI SD8"C900 SD12"C900 SD10 15 20 25 30 35 40 45 10 15 20 25 30 35 40 45 A14+00 A14+20 A14+40 A14+60 A14+80 A15+00 A15+20 A15+40 A15+60 A15+80 A16+00 A16+20 A16+40EXIST WEXIST SS (TO BE REMOVED)SEE DEMO SHT D-4145 LF 12" PP SD @ SLP=0.17% 48'' SDMH #7 IE(IN)8"(S)=30.32 IE(IN)8"(N)=29.46 IE(OUT)12"(W)=29.23 STA A15+87, 4' LT RIM=33.9748'' SDMH #6 IE(IN)12"(E)=28.98 IE(IN)8"(N)=29.42 IE(IN)8"(S)=30.20 IE(OUT)12"(W)=28.97 STA A14+42, 3' LT RIM=33.70 STA A14+53, 15' LT 13' LT 135 LF 12" PP SD @ SLP=0.30% 30.12 29.63 29.63 33.70 29.22 29.63 29.99 29.22 20100 40 60 PLAN SCALE: 1"=20' 18-2251 SD-4 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 2ND ST STORM PLAN & PROFILE STA A14+00 TO STA A16+40 SEO BAW TTT 24NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SD-R.dwg SD-4 11/10/2023 11:47 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CL S 2ND ST MATCHLINE STA A14+00SEE SHEET SD-3MATCHLINE STA A14+00SEE SHEET SD-3MORRISAVE S1 TYP 11 12 11 11 12 11 15 (TYP OF 3) CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 PROPOSED STORM DRAIN MAY HAVE CONFLICT OR SEQUENCE CONSTRAINT WITH EXIST UTILITY TO BE ABANDONED, CONTRACTOR SHALL TAKE APPROPRIATE MEASURES TO MAINTAIN THE FUNCTIONALITY OF THE EXIST UTILITY UNTIL SUCH TIME AS IT CAN BE ABANDONED INSTALL CB PER COR STD PLAN 200.00 INSTALL SDMH PER COR STD PLAN 201.00 CONNECT PIPE TO EXIST DRAINAGE STRUCTURE CONNECT EXIST STORM DRAIN PIPE TO NEW STRUCTURE SEE PROFILE 6 ON SHT SD-40 SEE PROFILE 7 ON SHT SD-40 CONDUCT SITE SPECIFIC UTILITY POTHOLING IN ADVANCE OF CONSTRUCTION TO CONFIRM LOCATION AND ELEVATION OF UTILITY, IF CONFLICT PREVENTS INSTALLATION OF A TYPE 1 CB, CONTRACTOR SHALL INSTALL A SHALLOW CONCRETE INLET WITH ENGINEER APPROVAL PER COR STD PLAN 200.3 AT NO ADDITIONAL COST TO THE CITY CONSTRUCTION NOTES: 1 11 12 15 19 2 2 419 507 20 19 19 20 20 24 24 CONNECT TO EXISTING TYPE 113 13 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS STA A14+53, 14.9' LT STA A14+53, 23.3' LT 13.2' LT TEMPORARY TYPE 1 CB INSTALLED AND REMOVED DUE TO SEWER CONFLICT 13 13 CONNECT PIPE TO EXISTING DRAINAGE STRUCTURE ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••32 32 3131 32 32 32 32 32STOPC5+00 C6+00 C7+00 C8+00 C9+00C5+00 C6+00 C7+00 C8+00 C9+00 E1+0 0 24" C900 SS24" C900 SS C5+00 C6+00 C7+00 C8+00 C9+00 STA C4+90, 13.6' LT 1-48'' SDMH #9 STA C5+33, 13.7' LT 1-48'' SDMH #10 STA C5+33, 20.9' LT 1-CB #13 IE(OUT)12"(S)=27.50 STA C6+85, 13.0' LT 1-48'' SDMH #11 STA C6+85, 21.0' LT 1-CB #14 IE(OUT)12"(S)=26.57 STA C8+39, 13.5' LT 1-48'' SDMH #12 STA C8+39, 21.0' LT 1-CB #15 IE(OUT)12"(S)=27.13 12"C900 SD 12"C900 SD 12"C900 SD 12"C900 SD 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 C4+80 C5+00 C5+20 C5+40 C5+60 C5+80 C6+00 C6+20 C6+40 C6+60 C6+80 C7+00 C7+20 C7+40 C7+60 C7+80 C8+00 C8+20 C8+40 C8+60 C8+80 C9+00 C9+20 C9+40 C9+60EXIST WSEXIST WS153 LF 12" C900 @ SLP=0.53%154 LF 12" C900 @ SLP=0.48% 48'' SDMH #10 IE(IN)12"(E)=23.09 IE(IN)12"(N)=27.50 IE(OUT)12"(W)=23.07 STA C5+33, 14' LT RIM=31.16 48'' SDMH #9 IE(IN)12"(E)=22.87 IE(OUT)12"(NW)=22.83 STA C4+90, 14' LT RIM=31.23 48'' SDMH #11 IE(IN)12"(E)=23.93 IE(IN)12"(N)=26.33 IE(OUT)12"(W)=23.90 STA C6+85, 13' LT RIM=31.38 144 LF 12" C900 @ SLP=0.45% 42 LF 12" C900 @ SLP=0.47% 48'' SDMH #12 IE(IN)12"(E)=24.65 IE(IN)12"(N)=26.98 IE(OUT)12"(W)=24.67 STA C8+39, 14' LT RIM=31.74EXIST UGPEXIST 12" WEXIST FHEXIST UGP(RECONNECT) (RECONNECT) IE(IN)12"(SE)=22.83 (RECONNECTED) 22.37 22.38 27.80 20100 40 60 PLAN SCALE: 1"=20' 18-2251 SD-7 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 3RD ST STORM PLAN & PROFILE STA C4+80 TO STA C9+60 SEO BAW TTT 25NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SD-R.dwg SD-7 11/10/2023 11:47 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CL S 3RD ST MATCHLINE STA C9+60SEE SHEET SD-8MATCHLINE STA A9+60SEE SHEET SD-811 12 1212 12 1 TYP 11 11 15 74CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 INSTALL CB PER COR STD PLAN 200.00 INSTALL CB PER COR STD PLAN 201.00 CONNECT EXIST STORM DRAIN PIPE TO NEW STRUCTURE INSTALL 5 LF OF 12-IN PP PIPE AT SLP=1.6% INSTALL 5 LF OF 12-IN PP PIPE AT SLP=1.2% INSTALL 5 LF OF 12-IN PP PIPE AT SLP=2.2% EXIST FRANCHISE UTILITY TO BE RELOCATED BY OTHERS DURING CONSTRUCTION, CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY PRIOR TO CONSTRUCTION CONSTRUCTION NOTES: 1 11 12 15 2727 24 24 25 26 25 26 27 250 300 107 111 115 125 112 112 112 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••32 31 31 3132 C10+00 C11+00 C12+00 C13+00 C14+0012"DI WC10+00 C11+00 C12+00 C13+00 C14+00 24" C900 SS 8" SDR 35 SS8" SDR 35 SS24" C900 SS 24" C900 SS C10+00 C11+00 C12+00 C13+00 C14+00 STA C9+83, 13.4' LT 1-48'' SDMH #13 STA C9+83, 21.1' LT 1-CB #16 IE(OUT)12"(S)=27.85 STA C12+63, 12.5' RT 1-48'' SDMH #16 STA C12+52, 20.6' RT 1-CB #18 STA C12+92, 21.8' RT 1-CB #19 STA C13+81, 10.0' RT 1-48'' SDMH #17 STA C13+82, 18.5' LT 1-48'' SDMH #18 18" PP SD18" PP SD 18" PP SD 24" PP SD18" PP SD12"P P S D 27.18 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 C9+60 C9+80 C10+00 C10+20 C10+40 C10+60 C10+80 C11+00 C11+20 C11+40 C11+60 C11+80 C12+00 C12+20 C12+40 C12+60 C12+80 C13+00 C13+20 C13+40 C13+60 C13+80 C14+00 C14+20 C14+40EXIST WEXIST TEXIST TEXIST UGP/COMM DUCTEXIST 12"SDIE=28.1EXIST G118 LF 18" PP SD @ SLP=0.65% 48'' SDMH #16 IE(IN)18"(E)=21.08 IE(IN)18"(N)=21.49 IE(IN)12"(E)=27.46 IE(IN)12"(SW)=27.30 IE(OUT)24"(S)=20.81 STA C12+63, 13' RT RIM=31.06 48'' SDMH #17 IE(IN)18"(N)=21.85 IE(OUT)18"(W)=21.85 STA C13+81, 10' RT RIM=31.56 48'' SDMH #18 IE(IN)18"(E)=22.09 IE(OUT)18"(S)=22.09 STA C13+82, 18' LT RIM=31.19 68 LF 18" PP SD @ SLP=0.49% 48'' SDMH #13 IE(IN)12"(N)=27.10 IE(OUT)12"(W)=25.30 STA C9+83, 13' LT RIM=31.39 0.72% 21.48 27.58 27.57 21.03 22.33 22.33 22.42 22.42 RIM=31.33 0.69%SHATTUCKAVE S20100 40 60 PLAN SCALE: 1"=20' 18-2251 SD-8 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 3RD ST STORM PLAN & PROFILE STA C9+60 TO STA C14+40 SEO BAW TTT 26NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SD-R.dwg SD-8 11/10/2023 11:47 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CL S 3RD ST MATCHLINE STA C9+60SEE SHEET SD-7MATCHLINE STA C14+40SEE SHEET SD-9MATCHLINE STA C9+60SEE SHEET SD-7MATCHLINE STA C14+40SEE SHEET SD-911 1212 12 12 1 TYP 13 11 FOR CONTINUATION SEE SHEET SD-16 FOR CONTINUATION SEE SHEET SD-16 48IN SDMH #14, SEE SHT SD-16 48IN SDMH #15, SEE SHT SD-16 11 CB #17, SEE SHT SD-16 15 34AT&T CRITICAL FIBER OPTIC, PROTECT IN PLACE PER 1-07.17 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 INSTALL CB PER COR STD PLAN 200.00 INSTALL CB PER COR STD PLAN 201.00 CONNECT PIPE TO EXIST DRAINAGE STRUCTURE CONNECT EXIST STORM DRAIN PIPE TO NEW STRUCTURE EXIST FRANCHISE UTILITY TO BE RELOCATED BY OTHERS PRIOR TO CONSTRUCTION SEE PROFILE 1 ON SHT SD-41 SEE PROFILE 2 ON SHT SD-41 INSTALL 6LF OF 12-IN PP PIPE AT SLP=1.3% EXIST FRANCHISE UTILITY TO BE RELOCATED BY OTHERS DURING CONSTRUCTION, CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY PRIOR TO CONSTRUCTION CONSTRUCTION NOTES: 1 11 12 13 15 18 27 200 201 205 207 212 300 305 309 24 18 20 20 18 19 19 20 24 27 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS CONC MON IN CASE REESTABLISHED PER DNR PERMIT 7373 - 18"Tx6"W •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••33 33 33 33 34 3433C15+00 C16+00 C17+00 C18+00 12"DI WC15+00 C16+00 C17+00 C18+00 24" C900 SS 24" C900 SS8" C900 SS24" C900 SS C15+00 C16+00 C17+00 C18+00 STA C14+50, 15.8' LT 1-48'' SDMH #19 STA C14+63, 21.1' RT 1-CB #21 STA C14+50, 20.9' LT 1-CB #20 STA C16+04, 14.0' LT 1-48'' SDMH #21 STA C16+25, 21.0' RT 1-CB #24 STA C17+24, 20.8' LT 1-CB #26 STA C17+23, 15.3' LT 1-48'' SDMH #22 STA C18+52, 20.8' LT 1-CB #27 STA C18+53, 14.2' LT 1-48'' SDMH #23 STA C18+41, 20.9' RT 1-CB #28 STA C17+23, 20.4' RT 1-CB #25 18" PP SD 18" PP SD18" PP SD 18" PP SD12" PP SD12"DI SD12"D I SD12"DI SD12"DI SD12"DI SD 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 C14+40 C14+60 C14+80 C15+00 C15+20 C15+40 C15+60 C15+80 C16+00 C16+20 C16+40 C16+60 C16+80 C17+00 C17+20 C17+40 C17+60 C17+80 C18+00 C18+20 C18+40 C18+60 C18+80EXIST WSEXIST WEXIST GEXIST W(TO BE ABAN)EXIST 4"SD(TO BE ABAN)EXIST WSEXIST GEXIST FHEXIST UGP154 LF 18" PP SD @ SLP=0.83% 119 LF 18" PP SD @ SLP=0.64%130 LF 18" PP SD @ SLP=0.51% 48'' SDMH #19 IE(IN)18"(E)=22.39 IE(IN)12"(N)=26.46 IE(IN)12"(S)=28.51 IE(OUT)18"(W)=22.42 STA C14+50, 16' LT RIM=31.77 48'' SDMH #21 IE(IN)18"(E)=23.62 IE(IN)12"(N)=24.32 IE(IN)12"(SE)=29.65 IE(OUT)18"(W)=23.67 STA C16+04, 14' LT RIM=32.62 48'' SDMH #22 IE(IN)18"(E)=24.31 IE(IN)12"(S)=29.42 IE(IN)12"(N)=27.41 IE(OUT)18"(W)=24.39 STA C17+23, 15' LT RIM=33.05 48'' SDMH #23 IE(IN)18"(E)=25.03 IE(IN)12"(S)=27.71 IE(IN)12"(N)=27.80 IE(OUT)18"(W)=24.97 STA C18+53, 14' LT RIM=33.36PROP 18" SSIE=17.0PROP SIDE SEWERPROP SIDE SEWER0.71% 0.66% 22.90 26.96 22.90 23.99 24.55 30.10 23.99 19' LT RIM=32.74 24.78 30.64 27.85 24.78 25.43 30.70 28.19 25.43WHITWORTHAVE S20100 40 60 PLAN SCALE: 1"=20' 18-2251 SD-9 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 3RD ST STORM PLAN & PROFILE STA C14+40 TO STA C18+80 SEO BAW TTT 27NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SD-R.dwg SD-9 11/10/2023 11:47 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CL S 3RD ST MATCHLINE STA C14+40SEE SHEET SD-8MATCHLINE STA C18+80SEE SHEET SD-10MATCHLINE STA C14+40SEE SHEET SD-8MATCHLINE STA C18+80SEE SHEET SD-1011 11 11 12 12 1 TYP 20 11 11 FOR CONTINUATION SEE SHEET SD-20 48IN SDMH #20, SEE SHT SD-20 11 12 CB #22, SEE SHT SD-20 CB #23, SEE SHT SD-20 11 12 335CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 INSTALL CB PER COR STD PLAN 200.00 INSTALL CB PER COR STD PLAN 201.00 EXIST FRANCHISE UTILITY TO BE RELOCATED BY OTHERS PRIOR TO CONSTRUCTION SEE PROFILE 3 ON SHT SD-41 SEE PROFILE 4 ON SHT SD-41 SEE PROFILE 5 ON SHT SD-41 SEE PROFILE 6 ON SHT SD-41 CONDUCT SITE SPECIFIC UTILITY POTHOLING IN ADVANCE OF CONSTRUCTION TO CONFIRM LOCATION AND ELEVATION OF UTILITY, IF CONFLICT PREVENTS INSTALLATION OF A TYPE 1 CB, CONTRACTOR SHALL INSTALL A SHALLOW CONCRETE INLET WITH ENGINEER APPROVAL PER COR STD PLAN 200.3 AT NO ADDITIONAL COST TO THE CITY EXIST FRANCHISE UTILITY TO BE RELOCATED BY OTHERS DURING CONSTRUCTION, CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY PRIOR TO CONSTRUCTION CONSTRUCTION NOTES: 1 11 12 18 27 2718 27 18 27 316 400 422 423415413405 401325321319315 19 21 21 22 22 19 20 21 22 24 24 24 24 24 27 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS TIED EXIST 6" STORM MAIN INTO SOUTH SIDE OF CB 28. ADDED 6" CO ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••3334 34 35 35 35 3636 3636H5+00H6+00C19+00 C20+00 C21+00 C22+00 C23+00R0+83R1+00 C19+00 C20+00 C21+00 C22+00 C23+00H5+00H6+0024" C900 SS8" SDR 35 SS24" C900 SS C19+00 C20+00 C21+00 C22+00 C23+00 STA C19+22, 15.0' LT 1-48'' SDMH #25 STA C19+18, 30.6' RT 1-48'' SDMH #26 STA C19+27, 37.3' RT 1-CB #31 STA C20+64, 21.5' RT 1-CB #33 STA C20+63, 15.0' LT 1-48'' SDMH #27 STA C20+64, 20.2' LT 1-CB #32 STA C21+98, 16.8' LT 1-48'' SDMH #28 STA C21+96, 11.7' RT 1-60'' SDMH #29 STA C22+38, 57.7' RT 1-CB #34 STA A19+58, 581.2' RT 1-CB #35 12" PP SD 12" C900 SD18" PP SD 12"DI SD12" PP SD12" PP SD6" SD 12"DI SD 12"DI SD8 " D I SD 12" DI S D 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 C18+80 C19+00 C19+20 C19+40 C19+60 C19+80 C20+00 C20+20 C20+40 C20+60 C20+80 C21+00 C21+20 C21+40 C21+60 C21+80 C22+00 C22+20 C22+40 C22+60 C22+80EXIST UGP/COM DUCTEXIST WSEXIST WSEXIST GSEXIST GEXIST WPROP 8"SSIE=23.7EXIST SDIE=30.2141 LF 12" PP SD @ SL P = 1 . 9 7 % 136 LF 12" PP SD @ S L P = 2 . 5 4 % 48'' SDMH #25 IE(IN)12"(E)=26.01 IE(IN)12"(N)=26.01 IE(IN)12"(S)=25.98 IE(OUT)18"(W)=25.43 STA C19+22, 15' LT RIM=33.61 48'' SDMH #27 IE(IN)12"(E)=28.75 IE(IN)12"(S)=30.72 IE(IN)12"(N)=31.00 IE(OUT)12"(W)=28.79 STA C20+63, 15' LT RIM=34.73 48'' SDMH #28 IE(IN)12"(S)=32.72 IE(OUT)12"(W)=32.19 STA C21+98, 17' LT RIM=35.51 69 LF 18" PP SD @ SLP=0.58%EXIST G(TO BE REMOVED)26.28 25.78 2.03% 2.41% 25.78 RIM=33.75 29.16 31.91 29.16 33.11 32.38 RIM=35.38 0.51% 26.28 26.28 20100 40 60 PLAN SCALE: 1"=20' 18-2251 SD-10 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 3RD ST STORM PLAN & PROFILE STA C18+80 TO STA C22+80 SEO BAW TTT 28NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SD-R.dwg SD-10 11/10/2023 11:47 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CLMATCHLINE STA C18+80SEE SHEET SD-9MATCHLINE STA C18+80SEE SHEET SD-9S 3RD ST 11 1212 1 TYP 11 11 CB #30 SEE SHT SD-21 12 12 11 SMITHERSAVE SMORRIS AVE SFOR CONTINUATION SEE SHEET SD-21 CB #29, SEE SHT SD-21 48IN SDMH #24 SEE SHT SD-21 11 12 15 15 68CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 INSTALL CB PER COR STD PLAN 200.00 INSTALL CB PER COR STD PLAN 201.00 CONNECT EXIST STORM DRAIN PIPE TO NEW STRUCTURE EXIST FRANCHISE UTILITY TO BE RELOCATED BY OTHERS PRIOR TO CONSTRUCTION SEE PROFILE 7 ON SHT SD-41 SEE PROFILE 8 ON SHT SD-41 SEE PROFILE 1 ON SHT SD-42 SEE PROFILE 6 ON SHT SD-41 PROFILE 2 ON SHT SD-42 CONDUCT SITE SPECIFIC UTILITY POTHOLING IN ADVANCE OF CONSTRUCTION TO CONFIRM LOCATION AND ELEVATION OF UTILITY, IF CONFLICT PREVENTS INSTALLATION OF A TYPE 1 CB, CONTRACTOR SHALL INSTALL A SHALLOW CONCRETE INLET WITH ENGINEER APPROVAL PER COR STD PLAN 200.3 AT NO ADDITIONAL COST TO THE CITY EXIST FRANCHISE UTILITY TO BE RELOCATED BY OTHERS DURING CONSTRUCTION, CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY PRIOR TO CONSTRUCTION CONSTRUCTION NOTES: 1 11 12 15 18 27 27 19 20 21 22 19 20 20 21 22 21 280 504 510 505 507 509 24 24 24 27 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS CONC MON IN CASE REESTABLISHED PER DNR PERMIT 7373 - 18"Tx6"W EXIST CB AND PIPE LEFT IN PLACE •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••323333323232 32 32 32 31 3 2 CRPL#2 51.5" STLCRPL#1 66" STLCRPL#3 66" STLCRPL#1 66" STLCRPL#2 51.5" STL••••••••••••••••••••••••FO DUCTFO DUCTF1+00 F2+00 F3+00 F4+00 F5+00 12"DI W12"DI W12"DI WA9+00A10+00E6+00E6+3812"DI WTSTS TSTS TSTS E11+51E11+00A9+00A10+00F1+00 F2+00 F3+00 F4+00 F5+00 8" SDR 35 SS8" SDR 35 SS2"PVC CONDUITF1+00 F2+00 F3+00 F4+00 F5+00 STA F2+53, 14.9' RT 1-48'' SDMH #30 STA F2+52, 21.7' RT 1-CB #37 STA F3+79, 20.9' RT 1-CB #39 STA F3+80, 15.1' RT 1-48'' SDMH #31 STA F3+80, 21.7' LT 1-CB #75 W/RECTANGULAR FRAME & VANED GRATE 1-CB STA F4+47, 15.3' RT 1-48'' SDMH #32 STA F4+47, 20.9' LT 1-CB #76 W/RECTANGULAR FRAME & VANED GRATE 1-CB 18" PP SD 18" PP SD 18" PP SD12"PP SD12"PP SD12"PP SDSTA F2+51, 21.1' LT 1-CB #74 W/RECTANGULAR FRAME & VANED GRATE 1-CB 15"PP SD8" DI SD(RECONNECT) 10 15 20 25 30 35 40 10 15 20 25 30 35 40 F1+00 F1+20 F1+40 F1+60 F1+80 F2+00 F2+20 F2+40 F2+60 F2+80 F3+00 F3+20 F3+40 F3+60 F3+80 F4+00 F4+20 F4+40 F4+60 F4+80 F5+00 F5+20 F5+40 F5+60EXIST T (2)PROP 4"WEXIST UGPEXIST TEXIST SDMH #68466 IE(IN)12"(N)=22.90 IE(OUT)18"(S)=22.90 IE(OUT)12"(E)=24.00 IE(OUT)12"(W)=24.00 STA F2+32, 17' RT RIM=31.46 48'' SDMH #30 IE(IN)18"(N)=22.76 IE(IN)12"(W)=27.44 IE(IN)12"(E)=23.48 IE(OUT)18"(S)=22.82 STA F2+53, 15' RT RIM=31.31 48'' SDMH #31 IE(IN)18"(N)=22.51 IE(IN)12"(E)=23.80 IE(IN)12"(W)=27.75 IE(OUT)18"(S)=22.61 STA F3+80, 15' RT RIM=31.62 48'' SDMH #32 IE(IN)18"(N)=22.01 IE(IN)12"(W)=22.97 IE(IN)12"(E)=24.08 IE(OUT)18"(S)=22.00 STA F4+47, 15' RT RIM=31.67 127 LF 18" PP SD @ SLP=0.24%67 LF 18" PP SD @ SLP=0.89% 142 LF 18" PP SD @ SLP=0.17% 48'' SDMH #2 STA A9+61, 50' RT SEE SHT SD-3 22.84 27.70 23.61 RIM=31.14 24.10 26.30 22.41 22.18 23.20 24.26 22.18 RIM=31.84 0.34% 0.34% 0.30% 21 LF 18" PP SD @ SLP=0.66% 0.33% 20100 40 60 PLAN SCALE: 1"=20' 18-2251 SD-15 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET SHATTUCK AVE S STORM PLAN & PROFILE STA F0+00 TO STA F5+60 SEO BAW TTT 29NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SD-R.dwg SD-15 11/10/2023 11:47 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CLS 2ND STMATCHLINE STA F5+60SEE SHEET SD-16SHATTUCK AVE S MATCHLINE STA F5+60SEE SHEET SD-161 TYP FOR CONTINUATION SEE SHEET SD-3 12 12 11 12 11 12 13 CB #1, SEE SHT SD-3 SDMH #1, SEE SHT SD-3 CB #2, SEE SHT SD-3 SDMH #2, SEE SHT SD-3 15 15TYP OF 2 12 15 53555416 AT&T CRITICAL FIBER OPTIC, PROTECT IN PLACE PER 1-07.17 AT&T CRITICAL FIBER OPTIC, PROTECT IN PLACE PER 1-07.17 12 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 INSTALL CB PER COR STD PLAN 200.00 INSTALL CB PER COR STD PLAN 201.00 CONNECT PIPE TO EXIST DRAINAGE STRUCTURE CONNECT EXIST STORM DRAIN PIPE TO NEW STRUCTURE PRIOR TO CONSTRUCTION, CONTRACTOR SHALL CONTACT CITY ENGINEER TO DETERMINE THE ACTUAL EXIST LATERAL STORM DRAIN LOCATION AND TO VERIFY IF THE EXIST STORM DRAIN LATERAL IS ACTIVE, IF STORM DRAIN LATERAL IS ACTIVE, RECONNECT EXIST PIPE TO NEW STORM DRAIN PIPE WITH NYLOPLAST FITTING OR APPROVED EQUAL, PER THE SPECIFICATIONS EXIST FRANCHISE UTILITY TO BE RELOCATED BY OTHERS PRIOR TO CONSTRUCTION SEE PROFILE 3 ON SHT SD-42 SEE PROFILE 4 ON SHT SD-42 SEE PROFILE 5 ON SHT SD-42 EXIST FRANCHISE UTILITY TO BE RELOCATED BY OTHERS DURING CONSTRUCTION, CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY PRIOR TO CONSTRUCTION CONSTRUCTION NOTES: 1 11 12 13 15 16 18 1818 19 19 18 20 18 20 27 27 21 19 20 21 27 211 212 220 300 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS 11 11 11 FOUND STORM LATERAL, REROUTED TO SDMH #2, 6'-8" DEEP ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••313131 31 •••••••••••••••••••••••••••••••••••••••••••••••••• F6+00 F7+00 F8+00 F9+00 F10+00 12"DI W F6+00 F7+00 F8+00 F9+00 F10+00 8" SDR 35 SS 24" C900 SSF6+00 F7+00 F8+00 F9+00 F10+00 STA F5+86, 21.1' RT 1-CB #17 STA F5+98, 10.9' RT 1-48'' SDMH #15 STA F5+89, 15.6' RT 1-48'' SDMH #14 STA F7+73, 21.3' LT 1-48" SDMH #56 W/ RECTANGULAR FRAME & VANED GRATE STA F7+70, 11.9' RT 1-48'' SDMH #33 STA F7+70, 20.6' RT 1-CB #42 STA F9+24, 18.5' LT 1-48" SDMH #52 W/RECTANGULAR FRAME & VANED GRATE STA F9+24, 15.1' RT 1-60'' SDMH #34 STA F8+96, 23.2' RT 1-CB #44 STA F9+60, 28.0' RT 1-CB #46 STA F10+01, 18.2' LT 1-CB #53 W/RECTANGULAR FRAME & VANED GRATE STA F10+01, 15.2' RT 1-48'' SDMH #35 STA F10+83, 18.2' LT 1-48'' SDMH #54 W/RECTANGULAR FRAME & VANED GRATE 18" PP SD 24" PP SD18" PP SD24" PP SD 24" PP SD12"PP SD12"PP SD12"D I S D 12"DI S D 12"C900 SD12"C900 SD12 "C 9 0 0 SD32'-2"5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 F5+60 F5+80 F6+00 F6+20 F6+40 F6+60 F6+80 F7+00 F7+20 F7+40 F7+60 F7+80 F8+00 F8+20 F8+40 F8+60 F8+80 F9+00 F9+20 F9+40 F9+60 F9+80 F10+00 F10+20 F10+40EXIST 12"WEXIST 12"SDIE=25.6EXIST UGPEXIST UGPEXIST TEXIST 16"WEXIST UGP/COMM DUCTEXIST WSEXIST GEXIST COMPROP 21" SSIE=18.8EXIST 12"SD(TO BE ABAN)EXIST T64 LF 18" PP SD @ SLP=0.14% 48'' SDMH #14 IE(IN)18"(N)=21.76 IE(IN)12"(S)=21.85 IE(IN)12"(NW)=27.09 IE(OUT)18"(SE)=21.76 STA F5+89, 16' RT RIM=31.03 48'' SDMH #15 IE(IN)18"(NW)=21.58 IE(OUT)18"(S)=21.58 STA F5+98, 11' RT RIM=31.12 48'' SDMH #16 SEE SHT SD-8 108 LF 24" PP SD @ SLP=0.30% 48'' SDMH #33 IE(IN)24"(N)=20.49 IE(IN)12"(W)=25.07 IE(IN)12"(E)=23.64 IE(OUT)24"(S)=20.46 STA F7+70, 12' RT RIM=30.70 60'' SDMH #34 IE(IN)24"(N)=19.46 IE(IN)12"(NW)=26.98 IE(IN)12"(E)=22.85 IE(IN)12"(S)=26.19 IE(OUT)24"(S)=19.46 STA F9+24, 15' RT RIM=30.65 154 LF 24" PP SD @ SLP=0.65% 10 LF 18" PP SD @ SLP=1.75% 48'' SDMH #35 IE(IN)24"(N)=19.60 IE(IN)12"(E)=20.06 IE(OUT)24"(S)=19.58 STA F10+01, 15' RT RIM=30.13 77 LF 24" PP SD @ SLP=0.18% (RECONNECT)EXIST UGPEXIST SS (TO BE ABAN)IE=23.0EXIST 4"GEXIST UGP0.33%21.72 26.80 21.69 21.69 RIM=31.26 105 LF 24" PP SD @ SLP=0.38% 20.63 25.14 20.63 STA F7+67, 14' RT 20.10 24.40 23.50 26.84 20.10 RIM=30.81 0.34% 13 LF 18" PP SD @ SLP=0.23% 19.84 20.24 19.84 0.34% IE(IN)12"(NE)=24.09 20100 40 60 PLAN SCALE: 1"=20' 18-2251 SD-16 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET SHATTUCK AVE S STORM PLAN & PROFILE STA F5+60 TO STA F10+40 SEO BAW TTT 30NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SD-R.dwg SD-16 11/10/2023 11:47 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILES 3RD STMATCHLINE STA F10+40SEE SHEET SD-17SHATTUCK AVE S MATCHLINE STA F5+60SEE SHEET SD-15MATCHLINE STA F5+60SEE SHEET SD-15MATCHLINE STA F10+40SEE SHEET SD-17EXIST GR @ ROW CL 12 12 15 1 TYP 15 11 11 12 12 12 12 13 SDMH #16, SEE SHT SD-8 S 3RD PLFOR CONTINUATION SEE SHEET SD-8 11 15 12 11 CB #19, SEE SHT SD-8 CB #18, SEE SHT SD-8 13 15 565710916 12 AT&T CRITICAL FIBER OPTIC, PROTECT IN PLACE PER 1-07.17 AT&T CRITICAL FIBER OPTIC, PROTECT IN PLACE PER 1-07.17 AT&T CRITICAL FIBER OPTIC, PROTECT IN PLACE PER 1-07.17 16 16 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 INSTALL CB PER COR STD PLAN 200.00 INSTALL CB PER COR STD PLAN 201.00 CONNECT PIPE TO EXIST DRAINAGE STRUCTURE CONNECT EXIST STORM DRAIN PIPE TO NEW STRUCTURE PRIOR TO CONSTRUCTION, CONTRACTOR SHALL CONTACT CITY ENGINEER TO DETERMINE THE ACTUAL EXIST LATERAL STORM DRAIN LOCATION AND TO VERIFY IF THE EXIST STORM DRAIN LATERAL IS ACTIVE, IF STORM DRAIN LATERAL IS ACTIVE, RECONNECT EXIST PIPE TO NEW STORM DRAIN PIPE WITH NYLOPLAST FITTING OR APPROVED EQUAL, PER THE SPECIFICATIONS EXIST FRANCHISE UTILITY TO BE RELOCATED BY OTHERS PRIOR TO CONSTRUCTION SEE PROFILE 6 ON SHT SD-42 SEE PROFILE 7 ON SHT SD-42 SEE PROFILE 8 ON SHT SD-42 SEE PROFILE 1 ON SHT SD-43 SEE PROFILE 2 ON SHT SD-43 CONDUCT SITE SPECIFIC UTILITY POTHOLING IN ADVANCE OF CONSTRUCTION TO CONFIRM LOCATION AND ELEVATION OF UTILITY, IF CONFLICT PREVENTS INSTALLATION OF A TYPE 1 CB, CONTRACTOR SHALL INSTALL A SHALLOW CONCRETE INLET WITH ENGINEER APPROVAL PER COR STD PLAN 200.3 AT NO ADDITIONAL COST TO THE CITY EXIST FRANCHISE UTILITY TO BE RELOCATED BY OTHERS DURING CONSTRUCTION, CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY PRIOR TO CONSTRUCTION CONSTRUCTION NOTES: 1 11 12 13 15 16 PLACE DENSE FOAM CUSHION PER THE SPECIFICATION BETWEEN SD AND W AS DIRECTED BY THE ENGINEER 18 18 SEE DET 2, SHT SD-45 18 18 19 20 21 22 23 24 19 20 20 27 22 21 22 23 301 207 220 2424 27 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS CONC MON IN CASE REESTABLISHED PER DNR PERMIT 7373 - 18"Tx6"W REPAIRED EXIST 6" CLAY SS LATERAL 13 13 TIED INTO EXIST CB TIED INTO EXIST CB 13 SS CONFLICT - CHANGED TO TYPE 1 CHANGED TO TYPE 1 CB •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 30 30 3030 29 29 29 •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• •••••••••••••••••••••••••••••••••••••••••••• •••••••••••••••••••••••••••••••••••••••••••• F11+00 F12+00 F13+00 F14+00 F15+00F11+00 F12+00 F13+00 F14+00 F15+00F11+00 F12+00 F13+00 F14+00 F15+00 STA F10+01, 15.2' RT 1-48'' SDMH #35 STA F10+82, 12.5' RT 1-48'' SDMH #36 STA F10+81, 21.4' RT 1-CB #49 STA F10+83, 18.2' LT 1-48'' SDMH #54 W/RECTANGULAR FRAME & VANED GRATE STA F12+02, 21.4' RT 1-CB #51 STA F12+04, 16.4' RT 1-60'' SDMH #38 STA F12+37, 27.1' LT 1-CB #52 STA F12+13, 15.3' RT 1-60'' SDMH #39 STA F13+65, 21.5' RT 1-CB #54 STA F13+64, 13.8' RT 1-60'' SDMH #40 STA F13+65, 20.5' LT 1-48" SDMH #55 W/RECTANGULAR FRAME & VANED GRATESTA F11+85, 27.6' LT 1-CB #50 STA F12+04, 29.6' LT 1-48'' SDMH #37 36" PP SD24" PP SD24" PP SD 12"PP SD24"PP SD18"PP SD36"PP SD 12"DI SD 12"DI SD12"DI SD 8'-0"(RECONNECT) (RECONNECT) 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 F10+40 F10+60 F10+80 F11+00 F11+20 F11+40 F11+60 F11+80 F12+00 F12+20 F12+40 F12+60 F12+80 F13+00 F13+20 F13+40 F13+60 F13+80 F14+00 F14+20 F14+40 F14+60 F14+80 F15+00EXIST GSEXIST WSEXIST UGPEXIST UGP121 LF 24" PP SD @ SLP=0.16%152 LF 36" PP SD @ SLP=0.19% 9 LF 24" PP SD @ SLP=1.74% 48'' SDMH #36 IE(IN)24"(N)=19.42 IE(IN)12"(E)=20.03 IE(IN)12"(W)=24.03 IE(OUT)24"(S)=19.37 STA F10+82, 12' RT RIM=30.04 149 LF 36" PP SD @ SLP=0.15% 60'' SDMH #40 IE(IN)36"(N)=18.49 IE(IN)12"(W)=23.93 IE(IN)12"(E)=21.69 IE(OUT)36"(S)=18.48 STA F13+64, 14' RT RIM=29.39 60'' SDMH #39 IE(IN)24"(N)=19.11 IE(IN)6"(W)=22.45 IE(OUT)36"(S)=18.78 STA F12+13, 15' RT RIM=29.60 81 LF 24" PP SD @ SLP=0.20% 60'' SDMH #38 IE(IN)24"(N)=19.17 IE(IN)18"(E)=19.21 IE(IN)12"(W)=21.55 IE(IN)18"(N)=21.58 IE(OUT)24"(S)=19.27 STA F12+04, 16' RT RIM=29.54 0.34%0.23% 0.19% 19.57 24.45 19.57 0.25% 18.78 23.60 18.78 RIM=29.55 19.13 RIM=29.71 0.34% 19.48 24.27 RIM=29.71 22.00 20100 40 60 PLAN SCALE: 1"=20' 18-2251 SD-17 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET SHATTUCK AVE S STORM PLAN & PROFILE STA F10+40 TO STA F15+00 JAM BAW TTT 31NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SD-R.dwg SD-17 11/10/2023 11:47 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CLS 4TH STMATCHLINE STA F15+00SEE SHEET SD-18SHATTUCK AVE S MATCHLINE STA F10+40SEE SHEET SD-16MATCHLINE STA F15+00SEE SHEET SD-18MATCHLINE STA F10+40SEE SHEET SD-1612 11 12 12 12 12 11 11 12 1 15 TYP 1111 12 15 15 15 12CONTRACTOR SHALL VERIFY EXIST SD ELEVATION PRIOR TO CONSTRUCTION. FINAL DEPTH OF SDMH #37 SHALL BE PER DIRECTION OF CITY ENGINEER AT&T CRITICAL FIBER OPTIC, PROTECT IN PLACE PER 1-07.17 AT&T CRITICAL FIBER OPTIC, PROTECT IN PLACE PER 1-07.17 16 16 1616 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 REPLACE SURVEY MONUMENT PER CITY STANDARD DETAIL H031 AS REQUIRED FOR CONSTRUCTION INSTALL CB PER COR STD PLAN 200.00 INSTALL CB PER COR STD PLAN 201.00 CONNECT EXIST STORM DRAIN PIPE TO NEW STRUCTURE PRIOR TO CONSTRUCTION, CONTRACTOR SHALL CONTACT CITY ENGINEER TO DETERMINE THE ACTUAL EXIST LATERAL STORM DRAIN LOCATION AND TO VERIFY IF THE EXIST STORM DRAIN LATERAL IS ACTIVE, IF STORM DRAIN LATERAL IS ACTIVE, RECONNECT EXIST PIPE TO NEW STORM DRAIN PIPE WITH NYLOPLAST FITTING OR APPROVED EQUAL, PER THE SPECIFICATIONS EXIST FRANCHISE UTILITY TO BE RELOCATED BY OTHERS PRIOR TO CONSTRUCTION SEE PROFILE 3 ON SHT SD-43 SEE PROFILE 4 ON SHT SD-43 SEE PROFILE 5 ON SHT SD-43 SEE PROFILE 6 ON SHT SD-43 CONDUCT SITE SPECIFIC UTILITY POTHOLING IN ADVANCE OF CONSTRUCTION TO CONFIRM LOCATION AND ELEVATION OF UTILITY CONSTRUCTION NOTES: 1 11 12 15 16 18 18 11336 408 416 418 440 19 20 21 22 22 20 20 21 21 19 24 24 8 8 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS 400 F12+03, 26.3' LT CONC. MON. IN CASE REESTABLISHED PER DNR PERMIT 7373 -18"T x 6"W F10+80, 18.2' LT CHANGED TO TYPE 1 CB C900 •••••••••••••••••••••••••••••••••••••• 29 28 28 2 8 •••••••••••••••••••••••••••••••••••••••••••••••••• • • •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• F15+00 F16+00 F16+80F15+00 F16+00 F16+58F15+00 F16+00 F16+80 STA F15+12, 21.6' RT 1-CB #56 STA F15+14, 11.1' RT 1-60'' SDMH #41 STA F15+11, 20.4' LT 1-CB #55 STA F15+47, 14.7' RT 1-60'' SDMH #42 STA F16+26, 14.1' RT 1-60'' SDMH #43 36" PP SD36" PP SD8"DI SD36"PP SD 0 5 10 15 20 25 30 35 0 5 10 15 20 25 30 35 F15+00 F15+20 F15+40 F15+60 F15+80 F16+00 F16+20 F16+40 F16+60 F16+80 F17+00EXIST UGPEXIST TEXIST T79 LF 36" PP SD @ SLP=0.00% 60'' SDMH #42 IE(IN)12"(E)=20.43 IE(IN)36"(N)=18.03 IE(OUT)36"(S)=17.93 STA F15+47, 15' RT RIM=28.43 60'' SDMH #43 IE(IN)36"(N)=17.93 IE(OUT)36"(S)=17.83 IE(OUT)12"(W)=22.03 STA F16+26, 14' RT RIM=28.03 60'' SDMH #41 IE(IN)36"(N)=18.26 IE(IN)12"(W)=22.76 IE(IN)8"(E)=26.21 IE(OUT)36"(S)=18.21 STA F15+14, 11' RT RIM=28.76 30 LF 36" PP SD @ SLP=0.07% EXIST SDMH #28665 IE(IN)36"(N)=17.81 IE(IN)12"(E)=25.32 IE(OUT)12"(W)=24.00 IE(OUT)48"(S)=17.55 STA F16+56, 15' RT RIM=28.10 (EXIST) (EXIST) (EXIST)34 LF 36" PP SD @ SLP=0.53% 0.23% 20.80 18.36 18.36 RIM=28.69 18.41 22.91 26.18 18.41 STA F15+11, 13' RT RIM=28.93 1.74% 17.66 (EXIST) (EXIST) (EXIST) 0.14% 36 18.18 18.18 23.00 20100 40 60 PLAN SCALE: 1"=20' 18-2251 SD-18 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET SHATTUCK AVE S STORM PLAN & PROFILE STA F15+00 TO STA F16+00 SEO BAW TTT 32NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SD-R.dwg SD-18 11/10/2023 11:47 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CL SHATTUCK AVE S MATCHLINE STA F15+00SEE SHEET SD-17MATCHLINE STA F15+00SEE SHEET SD-1712 1 TYP 13 S 4TH PL12 11 11 15 15 12 INVERT ELEVATIONS OF PIPE IN SDMH 28665 IS BASED ON AVAILABLE RECORD DRAWING DATA, CONTRACTOR SHALL CONFIRM INVERT ELEVATIONS PRIOR TO CONSTRUCTION 13AT&T CRITICAL FIBER OPTIC, PROTECT IN PLACE PER 1-07.17 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 INSTALL CB PER COR STD PLAN 200.00 INSTALL CB PER COR STD PLAN 201.00 CONNECT PIPE TO EXIST DRAINAGE STRUCTURE CONNECT EXIST STORM DRAIN PIPE TO NEW STRUCTURE EXIST FRANCHISE UTILITY TO BE RELOCATED BY OTHERS PRIOR TO CONSTRUCTION SEE PROFILE 7 ON SHT SD-43 EXIST FRANCHISE UTILITY TO BE RELOCATED BY OTHERS DURING CONSTRUCTION, CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY PRIOR TO CONSTRUCTION CONSTRUCTION NOTES: 1 11 12 13 15 18 18 432 450 19 27 27 19 19 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS F15+11, 13.2' RT AT&T CRITICAL FIBER OPTIC, PROTECT IN PLACE PER 1-07.17 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••3434333433 3333 33 33 CRPL #2 51.5" STLCRPL#3 66" STLCRPL#1 66" STL••••••••••••••••••••••••••••••••••••••FO DUCTFO DUCT12"DI W 12"DI WG0+00 G1+00 G2+00 G3+00 A12+00A13+0012"DIWTSTSTSTS TS TS G0+00 G1+00 G2+00 G3+00 A12+00A13+008" C900 SS8" C900 SS8" SDR 35 SSG0+00 G1+00 G2+00 G3+00 STA G0+47, 15.3' RT 1-48'' SDMH #4 STA G0+62, 19.1' RT 1-EXIST CB #5 STA G0+62, 14.7' LT 1-CB #7 STA G2+49, 9.9' LT 1-CB #58 STA G2+49, 15.4' LT 1-CB #57 STA G2+78, 19.6' RT 1-CB #59 12" PP SD 8"DI SD8 "D I S D12"DI SD8"DI SD 12"DI SD STA A12+98, 47.1' RT 1-MH (224)8"DI SD10 15 20 25 30 35 40 10 15 20 25 30 35 40 G0+00 G0+20 G0+40 G0+60 G0+80 G1+00 G1+20 G1+40 G1+60 G1+80 G2+00 G2+20 G2+40 G2+60 G2+80 G3+00 G3+20EXIST WSSIDE SEWERSIDE SEWERCB #58 IE(IN)8"(SW)=30.24 IE(IN)12"(E)=30.24 IE(OUT)12"(S)=27.44 STA G2+49, 10' LT RIM=32.79 160 LF 12" PP SD @ SLP=0.59% 0.71% 27.72 28.95 30.38 20100 40 60 PLAN SCALE: 1"=20' 18-2251 SD-19 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET WHITWORTH AVE S STORM PLAN & PROFILE STA G0+00 TO STA G3+20 SEO BAW TTT 33NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SD-R.dwg SD-19 11/10/2023 11:47 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CL WHITWORTH AVE S MATCHLINE STA G3+20SEE SHEET SD-20MATCHLINE STA G3+20SEE SHEET SD-2011 12 11 1 TYP FOR CONTINUATION SEE SHEET SD-3 FOR CONTINUATION SEE SHEET SD-3 S 2ND STCB #6, SEE SHT SD-3 SDMH #5, SEE SHT SD-3 11 11 12 17 <SEE SD-40 FOR PROFILE> CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 INSTALL CB PER COR STD PLAN 200.00 INSTALL CB PER COR STD PLAN 201.00 PRIOR TO CONSTRUCTION, CONTRACTOR SHALL CONTACT CITY ENGINEER TO DETERMINE THE ACTUAL EXIST LATERAL STORM DRAIN LOCATION TO VERIFY IF THE EXIST STORM DRAIN LATERAL IS ACTIVE, IF STORM DRAIN IS ACTIVE, RECONNECT EXIST PIPE TO NEW STRUCTURE SEE PROFILE 8 ON SHT SD-43 CONSTRUCTION NOTES: 1 11 12 17 400 319 215 220 19 19 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS LEFT EXISTING TYPE 1 IN PLACE 13 13 13 CONNECT PIPE TO EXISTING DRAINAGE STRUCTURE •••••••••••••••••••••••••••33333333 33••••••C16+00G4+00 G5+00 G6+00 12"DI W C16+00G4+00 G5+00 G6+00G6+00 24" C900 SS24" C900 SS8" C900 SS G6+00 G4+00 G5+00 G6+00 STA G5+14, 18.9' RT 1-CB #22 STA G5+19, 8.8' LT 1-48'' SDMH #20 STA G5+19, 14.9' LT 1-CB #23 STA G4+09, 15.7' LT 1-CB #60 STA G4+10, 10.2' LT 1-48'' SDMH #44 STA G4+06, 19.7' RT 1-CB #61 18" PP SD18" PP SD12" PP SD 12" PP SD 12"D I S D 12"DI SD12"DI SD10 15 20 25 30 35 40 10 15 20 25 30 35 40 G3+20 G3+40 G3+60 G3+80 G4+00 G4+20 G4+40 G4+60 G4+80 G5+00 G5+20 G5+40 G5+60 G5+80 G6+00EXIST WSEXIST GEXIST WSEXIST UGPEXIST GSEXIST UGPEXIST W(ABAN)EXIST W(TO BE ABAN)EXIST T48'' SDMH #20 IE(IN)12"(N)=24.80 IE(IN)12"(E)=27.03 IE(IN)12"(W)=29.77 IE(OUT)12"(S)=24.79 STA G5+19, 9' LT RIM=32.42 48'' SDMH #21 STA G5+39, 12' LT RIM=32.62 SEE SHT SD-9 48'' SDMH #44 IE(IN)12"(N)=26.49 IE(IN)12"(E)=26.93 IE(IN)12"(W)=29.28 IE(OUT)12"(S)=26.46 STA G4+10, 10' LT RIM=32.48 109 LF 12" PP SD @ SLP=1. 5 2 % 20 LF 12" PP SD @ SLP=2.38% 27.14 29.99 RIM=32.61 STA G5+3427.10 30.24 26.59 RIM=32.67 1.62% 15 1.70% 20100 40 60 PLAN SCALE: 1"=20' 18-2251 SD-20 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET WHITWORTH AVE S STORM PLAN & PROFILE STA G3+20 TO STA G6+00 SEO BAW TTT 34NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SD-R.dwg SD-20 11/10/2023 11:47 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CL WHITWORTH AVE S MATCHLINE STA G3+20SEE SHEET SD-19MATCHLINE STA G3+20SEE SHEET SD-19S 3RD ST11 11 12 11 11 FOR CONTINUATION SEE SHEET SD-9 48IN SDMH #21, SEE SHT SD-9 1 TYP FOR CONTINUATION SEE SHEET SD-9 CB #24, SEE SHT SD-9 153816 12 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 INSTALL CB PER COR STD PLAN 200.00 INSTALL CB PER COR STD PLAN 201.00 PRIOR TO CONSTRUCTION, CONTRACTOR SHALL CONTACT CITY ENGINEER TO DETERMINE THE ACTUAL EXIST LATERAL STORM DRAIN LOCATION AND TO VERIFY IF THE EXIST STORM DRAIN LATERAL IS ACTIVE, IF STORM DRAIN LATERAL IS ACTIVE, RECONNECT EXIST PIPE TO NEW STORM DRAIN PIPE WITH NYLOPLAST FITTING OR APPROVED EQUAL, PER THE SPECIFICATIONS EXIST FRANCHISE UTILITY TO BE RELOCATED BY OTHERS PRIOR TO CONSTRUCTION SEE PROFILE 1 ON SHT SD-44 SEE PROFILE 2 ON SHT SD-44 CONSTRUCTION NOTES: 1 11 12 16 18 400 322 401 325 321 18 19 20 20 20 19 19 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••3434 33 343435CRPL#1 66" STLCRPL#2 51.5" STLH3+00 H4+00 H5+00 H6+00 H6+60H3+00 H4+00 H5+00 H6+00 H6+60 8" SDR 35 SS 24" C900 SS24" C900 SSH3+00 H4+00 H5+00 H6+00 H6+60 STA H3+64, 19.2' LT 1-CB #62 STA H3+63, 13.0' LT 1-48'' SDMH #45 STA H3+62, 18.9' RT 1-CB #63 STA H4+85, 19.0' LT 1-CB #30 STA H4+85, 14.3' LT 1-48'' SDMH #24 STA C18+88, 69.7' LT 1-CB #29 STA H4+10, 19.1' RT 1-CB #64 STA H4+10, 14.7' LT 1-48'' SDMH #46 12" C900 SD 18" PP SD12" PP SD12" PP SD12" PP SD 12"D I S D12"DI SD12"DI SD12"DI SDTBD TBD 10 15 20 25 30 35 40 45 10 15 20 25 30 35 40 45 H3+20 H3+40 H3+60 H3+80 H4+00 H4+20 H4+40 H4+60 H4+80 H5+00 H5+20 H5+40 H5+60 H5+80 H6+00EXIST UGPEXIST WSEXIST TEXIST UGPEXIST UGPEXIST GEXIST FHEXIST GPROP 24"SSIE=15.0EXIST W76 LF 12" PP SD @ SLP=0.53%55 LF 12" PP SD @ SLP=0.47% 48'' SDMH #24 IE(IN)12"(N)=26.37 IE(IN)12"(W)=29.82 IE(IN)12"(E)=27.11 IE(OUT)12"(S)=26.27 STA H4+85, 14' LT RIM=33.11 48'' SDMH #45 IE(IN)12"(E)=27.27 IE(IN)12"(W)=27.02 IE(OUT)12"(S)=26.97 STA H3+63, 13' LT RIM=33.22 46 LF 12" C900 SD @ SLP=0.68% 48'' SDMH #25 STA H5+40, 14' LT RIM=33.61 SEE SHT SD-10 48'' SDMH #26 IE(IN)12"(SE)=27.54 IE(IN)6"(NW)=30.99 IE(OUT)12"(N)=26.29 STA H5+86, 10' LT RIM=33.44 48'' SDMH #46 IE(IN)12"(N)=26.87 IE(IN)12"(W)=29.52 IE(OUT)12"(S)=26.77 STA H4+10, 15' LT RIM=33.22 47 LF 12" PP SD @ SLP=0.21%EXIST UGPEXIST SS0.50% 0.50% 26.56 31.03 27.49 26.56 RIM=33.29 27.67 30.43 27.19 STA H3+59 0.50% RIM=33.75 28.02 26.48 STA H5+81 30.73 RIM=33.35 0.50% (RECONNECT) 18-2251 SD-21 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET MORRIS AVE S STORM PLAN & PROFILE STA H3+20 TO STA H6+00 SEO BAW TTT 35NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SD-R.dwg SD-21 11/10/2023 11:47 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 20100 40 60 PLAN SCALE: 1"=20' MORRIS AVE S S 3RD STEXIST GR @ ROW CL SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE 11 12 11 11 48 IN SDMH #25, SEE SHT SD-10 1 TYP FOR CONTINUATION SEE SHEET SD-10 FOR CONTINUATION SEE SHEET SD-9 11 12 48 IN SDMH #26, SEE SHT SD-10 15 15 48IN SDMH #23, SEE SHT SD-9 CB #31, SEE SHT SD-10 CB #28, SEE SHT SD-9 CB #27, SEE SHT SD-9 15 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 INSTALL CB PER COR STD PLAN 200.00 INSTALL CB PER COR STD PLAN 201.00 CONNECT EXIST STORM DRAIN PIPE TO NEW STRUCTURE SEE PROFILE 3 ON SHT SD-44 SEE PROFILE 4 ON SHT SD-44 SEE PROFILE 5 ON SHT SD-44 CONSTRUCTION NOTES: 1 11 12 15 280 422 425 19 20 21 20 19 21 21 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS 59, 19.9 59, 13.2 69, 20.0 APPROXIMATE PROPOSED RADIUS APTS BUILDING WALL APPROXIMATE PROPOSED RADIUS APTS BUILDING SD DISCHARGE LINE ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••4645 4546 4 646 CRPL#3 66" STLCPPL#3 66" STL K3+00 K4+00 STA K3+11, 20.3' RT 1-48'' SDMH #47 STA K3+55, 8.5' RT 1-48'' SDMH #48 STA K3+56, 17.3' RT 1-CB #6812"PP SD 24"C900 S D 20 25 30 35 40 45 50 55 20 25 30 35 40 45 50 55 K2+80 K3+00 K3+20 K3+40 K3+60 K3+80 K4+00PROP 12"CIPP SSPROP 12" WEXIST 66"W (SPU)48'' SDMH #48 IE(IN)24"(W)=39.07 IE(IN)12"(S)=40.92 IE(IN)6"(SE)=39.12 IE(OUT)12"(E)=38.57 (RECONNECT) STA K3+55, 9' RT RIM=45.42 48'' SDMH #47 IE(IN)12"(S)=39.16 IE(IN)12"(W)=39.11 IE(OUT)24"(E)=39.93 STA K3+11, 20' RT RIM=45.46 (RECONNECT)EXIST 6"W45 LF 24" C900 @ SLP=1.90% 39.10 41.79 39.20 (RECONNECT) 0.22% 38.80 20100 40 60 PLAN SCALE: 1"=20' 18-2251 SD-24 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 2ND ST STORM PLAN & PROFILE STA K2+80 TO STA K4+00 SEO BAW TTT 36NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SD-R.dwg SD-24 11/10/2023 11:47 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CL S 2ND ST MILL AVE S1 TYP 15 15 11 12 12 FOR CONTINUATION SEE SHEET SD-25 CB #67, SEE SHT SD-25 CB #66, SEE SHT SD-25 CB #65, SEE SHT SD-25 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 INSTALL CB PER COR STD PLAN 200.00 INSTALL CB PER COR STD PLAN 201.00 CONNECT EXIST STORM DRAIN PIPE TO NEW STRUCTURE SEE PROFILE 6 ON SHT SD-44 SEE PROFILE 7 ON SHT SD-44 CONSTRUCTION NOTES: 1 11 12 15 1010 19 20 PLACE DENSE FOAM CUSHION PER THE SPECIFICATION BETWEEN SD AND SS AS DIRECTED BY ENGINEER 20 19 GAS WILL BE DEACTIVATED BY PSE PRIOR TO CONSTRUCTION RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS CONC. MON. IN CASE REESTABLISHED PER DNR PERMIT 7373-18"T x 6"W REMOVE EXISTING CATCH BASIN AND PROTECT EXISTING 12" SS 13 CONNECT NEW PIPE TO EXISTING STRUCTURE 13 EXIST SDMH KEPT IN PLACE RECONNECTED PIPE FROM SE ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••46 454644 45 4544 4 4 45 46 4 343 CRPL#3 66" STL CPPL#3 66" STLK3+00K4+00L0+00 L1+00 L2+00 L3+00 L4+00 12"DI W TS TS TS L0+00 L1+00 L2+00 L3+00 L4+00 K3+00K4+0012" C900 SS8" SDR 35 SS12" CIPP SSC 9 0 0C900 L0+00 L1+00 L2+00 L3+00 L4+00 STA L4+31, 17.4' RT 1-CB #65 STA L4+61, 14.8' LT 1-CB #67 STA L4+60, 17.5' RT 1-CB #66 12"PP SD24"C900 SD25 30 35 40 45 50 55 60 25 30 35 40 45 50 55 60 L0+40 L0+60 L0+80 L1+00 L1+20 L1+40 L1+60 L1+80 L2+00 L2+20 L2+40 L2+60 L2+80 L3+00 L3+20 L3+40 L3+60 L3+80 L4+00 L4+20 L4+40 L4+60 L4+80 48'' SDMH #47 IE(IN)12"(S)=39.16 IE(IN)12"(W)=39.11 IE(OUT)24"(E)=39.93 STA L4+16, 14' RT RIM=45.46 CB #67 IE(IN)12"(S)=41.50 IE(OUT)12"(W)=41.49 STA L4+61, 15' LT RIM=45.03EXIST 2"G15 LF 12" PP SD @ SLP=4.70% CB #65 IE(IN)12"(S)=39.90 IE(OUT)12"(N)=39.87 STA K3+07, 35' RT RIM=44.92 CB #66 IE(IN)12"(E)=41.24 IE(OUT)12"(N)=40.11 STA L4+60, 17' RT RIM=45.02 29 LF 12"C900 @ SLP=0.72%PROP 12"CIPP SSEXIST TEXIST TEXIST UGP (2)EXIST 2"GEXIST SS LATSPU CRPL BEYOND 39.20 5.66% 40.05 40.05 RIM=44.72 41.40 41.40 4.66% SDR 35 SDR 35 18-2251 SD-25 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET MILL AVE S STORM PLAN & PROFILE STA L0+00 TO STA L4+80 SEO BAW TTT 37NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SD-R.dwg SD-25 11/10/2023 11:47 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE MILL AVE S S 2ND STFOR CONTINUATION SEE SHEET SD-24 MATCHLINE STA L4+80SEE SHEET SD-2620100 40 60 PLAN SCALE: 1"=20' EXIST GR @ ROW CL MATCHLINE STA L4+80SEE SHEET SD-266970CB #68, SEE SHT SD-24 16 11 11 11 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 INSTALL CB PER COR STD PLAN 200.00 PRIOR TO CONSTRUCTION, CONTRACTOR SHALL CONTACT CITY ENGINEER TO DETERMINE THE ACTUAL EXIST LATERAL STORM DRAIN LOCATION AND TO VERIFY IF THE EXIST STORM DRAIN LATERAL IS ACTIVE, IF STORM DRAIN LATERAL IS ACTIVE, RECONNECT EXIST PIPE TO NEW STORM DRAIN PIPE WITH NYLOPLAST FITTING OR APPROVED EQUAL, PER THE SPECIFICATIONS SEE PROFILE 6 ON SHT SD-44 SEE PROFILE 7 ON SHT SD-44 CONSTRUCTION NOTES: 1 11 16 SDMH #48, SEE SHT SD-24 SDMH #47, SEE SHT SD-24 1 TYP 100 1023 1010 19 20 20 19 GAS WILL BE DEACTIVATED BY PSE PRIOR TO CONSTRUCTION RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS CONC. MON. IN CASE REESTABLISHED PER DNR PERMIT 7373-18"T x 6"W 4" LATERAL FOUND AND RECONNECTED AT STA 4+43 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••4 7 47 4 7 48 4 9 5 3 5 2 5 1 5 0 4 9 48 47474746 46 46 46 46 45 CRPL#3 66" STLCRPL#3 66" STL CRPL#3 66" STL CRPL#3 66" STL L5+00 L6+00 L7+00 L8+00 L9+00L9+00 STA L6+58, 14.9' LT 1-CB #73 12" PP SD STA L6+58, 17.1' RT 1-CB #72 STA L5+67, 14.9' LT 1-CB #71 STA L5+67, 17.4' RT 1-CB #70 STA L5+36, 17.3' RT 1-CB #69 12"PP SD 8"C900 SD8"C900 SD8"DI SD 25 30 35 40 45 50 55 60 25 30 35 40 45 50 55 60 L4+80 L5+00 L5+20 L5+40 L5+60 L5+80 L6+00 L6+20 L6+40 L6+60 L6+80 L7+00 L7+20 L7+40 L7+60 L7+80 L8+00 L8+20 L8+40 L8+60 L8+80 L9+00 106 LF 12" PP SD @ SLP=0.36% CB #73 IE(IN)8"(W)=42.59 IE(OUT)12"(N)=42.59 STA L6+58, 15' LT RIM=45.83 CB #71 IE(IN)12"(S)=42.04 IE(IN)8"(W)=41.87 IE(OUT)12"(N)=41.88 STA L5+67, 15' LT RIM=45.14 91 LF 12" PP SD @ SLP=0.60%EXIST SIDE SEWEREXIST SIDE SEWER0.40% 42.17 42.00 42.00 0.50% 18-2251 SD-26 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET MILL AVE S STORM PLAN & PROFILE STA L4+80 TO STA L9+00 SEO BAW TTT 38NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SD-R.dwg SD-26 11/10/2023 11:47 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE MILL AVE S HOUSER WAY SMATCHLINE STA L4+80SEE SHEET SD-2520100 40 60 PLAN SCALE: 1"=20'MATCHLINE STA L4+80SEE SHEET SD-25EXIST GR @ ROW CL 17 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 INSTALL CB PER COR STD PLAN 200.00 CONNECT EXIST STORM DRAIN PIPE TO NEW STRUCTURE PRIOR TO CONSTRUCTION, CONTRACTOR SHALL CONTACT CITY ENGINEER TO VERIFY IF THE EXIST STORM DRAIN LATERAL IS ACTIVE. IF STORM DRAIN LATERAL IS ACTIVE, RECONNECT EXIST PIPE TO NEW STRUCTURE SEE PROFILE 8 ON SHT SD-44 SEE PROFILE 1 ON SHT SD-45 CONSTRUCTION NOTES: 1 11 15 1111 11 11 11 1 TYP 15 15 17 211 19 20 20 19 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS SCALE: 1"=20' HORIZ; 1"=5' VERT CB #1 TO SDMH #1 10 15 20 25 30 35 40 10 15 20 25 30 35 40 0+80 1+00 1+20 1+40 48'' SDMH #1 (EXIST) IE(IN)12"(N)=27.98 IE(IN)15"(E)=26.23 IE(OUT)12"(S)=22.80 IE(OUT)12"(W)=22.87 STA A9+52, 19' LT RIM=31.80 CB #1 IE(OUT)12"(S)=28.18 RIM=31.43 (EXIST) (EXIST) 5 LF 12" PP SD @ SLP=4.36% 28.38 27.50 23.18 27.50 RIM=32.17 28.41 (EXIST) (EXIST) 5 LF 12" PP SD @ SLP=0.47% SCALE: 1"=20' HORIZ; 1"=5' VERT SDMH #2 TO CB #2 10 15 20 25 30 35 40 10 15 20 25 30 35 40 1+00 1+20 1+40 1+60 48'' SDMH #2 IE(IN)12"(N)=22.68 IE(IN)8"(E)=22.88 IE(IN)12"(E)=25.53 IE(OUT)12"(S)=22.48 STA A9+61, 50' RT RIM=31.78 CB #2 IE(OUT)8"(W)=25.30 RIM=31.32EXIST 8"W(REMOVE)EXIST 3"TEXIST T DUCTEXIST 24"SSPROP 12"SSEXIST UGP (3)PROP 12"WPLACE DENSE FOAM PER THE SPECS BETW SD & T AS DIRECTED BY THE ENGINEER 41 LF 8" C900 @ SLP=5.86% 22.94 29.39 23.00 RIM=31.96 29.60 0.50% EXIST SDMH 62637 IE(IN)4"(SE)=24.11 (EXIST) (EXIST) (EXIST) SCALE: 1"=20' HORIZ; 1"=5' VERT CB #3 TO CB #4 10 15 20 25 30 35 40 10 15 20 25 30 35 40 1+00 1+20 1+40 1+60 1+80 2+00 CB #4 IE(OUT)8"(N)=30.55 RIM=32.03PROP 12"WEXIST UGP71 LF 8" PP @ SLP=0.25%EXIST 8" W(REMOVE)EXIST 66"W (SPU)48'' SDMH #3 IE(IN)12"(E)=27.35 IE(IN)8"(S)=30.37 IE(IN)12"(N)=28.15 IE(OUT)15"(W)=27.01 STA A10+84, 18' LT RIM=32.42 5 LF 12" C900 @ SLP=3.59% CB #3 IE(OUT)12"(S)=28.34 RIM=32.04EXIST 8"SSPROP 8"SSIE=19.3±27.97 27.72 28.92 0.54% 28.95 IN SCALE: 1"=20' HORIZ; 1"=5' VERT SDMH #4 TO CB #7 10 15 20 25 30 35 40 10 15 20 25 30 35 40 1+00 1+20 1+40 1+60EXIST 8"W(ABAN)34 LF 8" DI SD @ SLP=0.50% 48'' SDMH #4 IE(IN)8"(S)=28.40 IE(IN)8"(SE)=30.82 IE(OUT)12"(N)=30.25 IE(OUT)12"(W)=28.30 STA A12+71, 47' RT RIM=32.53EXIST UGP (3)EXIST T(2)(REMOVED)PROP 12"WPROP 8"SS34 LF 8" DI SD @ SLP=0.50% SCALE: 1"=20' HORIZ; 1"=5' VERT CB #8 TO CB #9 10 15 20 25 30 35 40 10 15 20 25 30 35 40 1+00 1+20 1+40 1+60 1+80 CB #8 IE(OUT)8"(S)=30.86 RIM=32.78 CB #9 IE(OUT)8"(N)=30.31 RIM=32.66EXIST 12"WPROP 8"SSEXIST 18"SS(ABAN)EXIST 12"SSEXIST TEXIST UGPEXIST 66"W (SPU)48'' SDMH #6 IE(IN)12"(E)=28.98 IE(IN)8"(N)=29.42 IE(IN)8"(S)=30.20 IE(OUT)12"(W)=28.97 STA A14+42, 3' LT RIM=33.70 20 LF 8" DI SD @ SLP=7.28% 51 LF 8" C900 @ SLP=0.22% PLACE DENSE FOAM PER THE SPECS BETW SD & UGP AS DIRECTED BY THE ENGINEER 29.67 29.22 29.63 29.99 29.22 STA A14+53, 15' LT 8 LF 0.48% 64 0.50% 12"PP SCALE: 1"=20' HORIZ; 1"=5' VERT CB #6 TO CB #5 10 15 20 25 30 35 40 10 15 20 25 30 35 40 1+00 1+20 1+40 1+60 1+80 2+00 2+20 EXIST CB #5 IE(IN)8"(E)=30.30 IE(OUT)8"(N)=30.20 RIM=32.30 48'' SDMH #5 IE(IN)12"(E)=27.80 IE(IN)12"(S)=30.00 IE(IN)12"(N)=28.32 IE(OUT)12"(W)=27.80 STA A12+69, 15' LT RIM=32.89 CB #6 IE(OUT)12"(S)=28.73 RIM=32.22 EXIST UGPEXIST UGP (2) (REMOVE)EXIST 8"W(REMOVE)PROP 12"WEXIST UGP (2)PROP 8"SSIE=19.2±EXIST UGP & TEXIST 66"W (SPU)EXIST 18"SS(ABAN)EXIST 12"SS(REMOVE)48'' SDMH #4 IE(IN)8"(S)=28.40 IE(IN)8"(SE)=30.82 IE(OUT)12"(N)=30.25 IE(OUT)12"(W)=28.30 RIM=32.53 15 LF 8" DI SD @ SLP=11.66% 8 LF 12" PP SD @ SLP=5.07% PLACE DENSE FOAM PER THE SPECS BETW SD & W AS DIRECTED BY THE ENGINEER EXIST CB LEFT IN SERVICE 30.47 RIM=32.2228.53 29.12 28.53 29.17 RIM=32.35 EXIST SDMH 63337 0.56%62 LF 12" DI @ SLP=0.40% 34 LF 8" DI SD @ SLP=3.93% CB #7 RIM=32.26 IE(OUT)8"(NW)=30.56 2+20 EXIST CB LEFT IN SERVICE TO CB #7 33.31 30.99 30.47 30.25 SCALE: 1"=20' HORIZ; 1"=5' VERT CB #10 TO CB #12 10 15 20 25 30 35 40 10 15 20 25 30 35 40 1+00 1+20 1+40 1+60 1+80 2+00 2+20 2+40EXIST 6"SS(REMOVE)EXIST 12"SS(REMOVE)EXIST 12"WEXIST 18"SS(REMOVE)PROP 8"SSEXIST UGP & TEXIST 6"SS(ABAN)EXIST 12"WPROP 8"SSEXIST G38 LF 8" DI SD @ SLP=0.29% CB #10 IE(OUT)8"(S)=32.59 RIM=33.99 48'' SDMH #7 IE(IN)8"(S)=30.32 IE(IN)8"(N)=29.46 IE(OUT)12"(W)=29.23 STA A15+87, 4' LT RIM=33.97 48'' SDMH #8 IE(IN)8"(S)=30.53 IE(OUT)8"(N)=30.60 STA A15+85, 48' RT RIM=32.85 CB #11 IE(IN)8"(E)=30.60 IE(OUT)8"(N)=30.63 RIM=32.75 CB #12 IE(OUT)8"(W)=30.71 RIM=32.73 19 LF 8" DI SD @ SLP=16.64%EXIST 66"W (SPU)52 LF 8" C900 @ SLP=0.54% 13 LF 8" DI SD @ SLP=0.75% 0.50% 29.86 RIM=32.98 30.12 29.63 29.63 STA A15+88, 13' LT RIM=33.70 30.75 30.42 30.84 30.84 31.03 60 LF 12" C900 @ SLP=0.50% 0.64% CB 66459 (EXIST)4'4" FOAM 10 LF 2.31% 12"PP CB 66459 (EXIST) 18-2251 SD-40 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET LATERAL DRAINAGE PROFILES - 1 SEO BAW TTT 39NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SD-LATERALS-R.dwg SD-40 11/10/2023 12:05 PM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 2550751426 SD-4 5 SD-3 2 SD-3 3 SD-3 1 SD-3 4 SD-3 277 SD-458614314RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS SPU PIPE 4' DEEP SCALE: 1"=20' HORIZ; 1"=5' VERT CB #18 TO CB #19 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 1+00 1+20 1+40 1+60 CB #18 IE(OUT)12"(NE)=27.52 RIM=30.58 48'' SDMH #16 IE(IN)18"(E)=21.08 IE(IN)18"(N)=21.49 IE(IN)12"(E)=27.46 IE(IN)12"(SW)=27.30 IE(OUT)24"(S)=20.81 STA C12+63, 13' RT RIM=31.06 CB #19 IE(OUT)12"(W)=27.76 RIM=30.73EXIST 12"SD(ABAN)EXIST 4"GEXIST 12"W14 LF 12" PP SD @ SLP=1.62% 30 LF 12" DI SD @ SLP=0.99%EXIST 4"G30.75 21.48 27.58 27.57 21.03 RIM=30.86 0.45%0.52% 27.63 SCALE: 1"=20' HORIZ; 1"=5' VERT CB #20 TO CB #21 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 1+00 1+20 1+40 1+60 39 LF 12" DI SD @ SLP=3.12% CB #20 IE(OUT)12"(S)=26.62 RIM=31.50 48'' SDMH #19 IE(IN)18"(E)=22.39 IE(IN)12"(N)=26.46 IE(IN)12"(S)=28.51 IE(OUT)18"(W)=22.42 STA C14+50, 16' LT RIM=31.77 CB #21 IE(OUT)12"(N)=29.73 RIM=31.58 5 LF 12" PP SD @ SLP=3.10%EXIST 12"WPROP 24"SSEXIST 4"G0.48% 27.00 22.90 26.96 29.43 22.90 0.85% SCALE: 1"=20' HORIZ; 1"=5' VERT SDMH #21 TO CB #24 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 1+00 1+20 1+40 1+60EXIST 12"WEXIST 4"GPROP 24"SSEXIST UGP41 LF 12" DI SD @ SLP=1.94% 48'' SDMH #21 IE(IN)18"(E)=23.62 IE(IN)12"(N)=24.32 IE(IN)12"(SE)=29.65 IE(OUT)18"(W)=23.67 STA C16+04, 14' LT RIM=32.62 CB #24 IE(OUT)12"(NW)=30.44 RIM=32.33 0.51% 23.99 24.55 30.10 23.99 19' LT RIM=32.74 30.33 SCALE: 1"=20' HORIZ; 1"=5' VERT CB #26 TO CB #25 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 1+00 1+20 1+40 1+60EXIST 4"GPROP 24"SSEXIST 12"W36 LF 12" DI SD @ SLP=4.21% CB #25 IE(OUT)12"(N)=30.92 RIM=32.71 48'' SDMH #22 IE(IN)18"(E)=24.31 IE(IN)12"(S)=29.42 IE(IN)12"(N)=27.41 IE(OUT)18"(W)=24.39 STA C17+23, 15' LT RIM=33.05 CB #26 IE(OUT)12"(S)=28.06 RIM=32.74 EXIST UGP6 LF 12" PP SD @ SLP=11.62% 0.51% RIM=32.83 24.78 30.64 27.85 24.78 0.47% 27.88 SCALE: 1"=20' HORIZ; 1"=5' VERT CB #27 TO CB #28 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 1+00 1+20 1+40 1+60 37 LF 12" DI SD @ SLP=8.61% 7 LF 12" PP SD @ SLP=13.70% CB #27 IE(OUT)12"(S)=28.70 RIM=33.09 48'' SDMH #23 IE(IN)18"(E)=25.03 IE(IN)12"(S)=27.71 IE(IN)12"(N)=27.80 IE(OUT)18"(W)=24.97 STA C18+53, 14' LT RIM=33.36 CB #28 IE(OUT)12"(N)=30.92 RIM=32.93EXIST 4"GPROP 24"SSEXIST 12"WEXIST UGP0.77% 0.37% RIM=33.21 25.43 30.70 28.19 25.43 RIM=33.11 28.81 SCALE: 1"=20' HORIZ; 1"=5' VERT CB #32 TO CB #33 10 15 20 25 30 35 40 45 10 15 20 25 30 35 40 45 1+00 1+20 1+40 1+60EXIST 12"WPROP 24"SSEXIST 4"GCB #32 IE(OUT)12"(S)=30.73 RIM=34.51 48'' SDMH #27 IE(IN)12"(E)=28.75 IE(IN)12"(S)=30.72 IE(IN)12"(N)=31.00 IE(OUT)12"(W)=28.79 STA C20+63, 15' LT RIM=34.73 CB #33 IE(OUT)12"(N)=32.30 RIM=34.41 37 LF 12" DI SD @ SLP=4.33% 5 LF 12" PP SD @ SLP=5.04% 31.40 29.16 31.91 29.16 32.09 0.50% 8.01% N/A SCALE: 1"=20' HORIZ; 1"=5' VERT SDMH #26 TO CB #31 10 15 20 25 30 35 40 45 10 15 20 25 30 35 40 45 0+00 0+19 CB #31 IE(OUT)12"(NW)=28.29 RIM=33.06 48'' SDMH #26 IE(IN)12"(SE)=27.54 IE(IN)6"(NW)=30.99 IE(OUT)12"(N)=26.29 STA C19+18, 31' RT RIM=33.44 12 LF 12" PP SD @ SLP=6.45% 28.10 28.02 26.48 25' RT 0.54% 15 LF SCALE: 1"=20' HORIZ; 1"=5' VERT SDMH #17 TO SDMH #18 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 0+80 1+00 1+20 1+40EXIST 12"WPROP 24"SS48'' SDMH #17 IE(IN)18"(N)=21.85 IE(OUT)18"(W)=21.85 RIM=31.56 28 LF 18" PP SD @ SLP=0.84% 48'' SDMH #18 IE(IN)18"(E)=22.09 IE(OUT)18"(S)=22.09 STA C13+82, 18' LT RIM=31.19 22.33 22.33 0.31% 22.42 22.42 RIM=31.33 18-2251 SD-41 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET LATERAL DRAINAGE PROFILES - 2 SEO BAW TTT 40NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SD-LATERALS-R.dwg SD-41 11/10/2023 12:05 PM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 101076262626 SD-9 5 SD-9 4 SD-9 2 SD-8 468 SD-10 7 SD-10 1 SD-8 3 SD-9 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS SCALE: 1"=20' HORIZ; 1"=5' VERT CB #39 TO SDMH #50 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 1+00 1+20 1+40 1+60PROP 8"SS &EXIST 10"SSPROP 12"WEXIST 3"TEXIST T DUCTEXIST 8"W(ABAN)37 LF 12" PP SD @ SLP=8.97% CB #75 IE(OUT)12"(W)=27.10 RIM=31.21 48'' SDMH #31 IE(IN)18"(N)=22.51 IE(IN)12"(E)=23.80 IE(IN)12"(W)=27.75 IE(OUT)18"(S)=22.61 STA F3+80, 15' RT RIM=31.62 CB #39 IE(OUT)12"(E)=27.93 RIM=31.26 6 LF 12" PP SD @ SLP=3.09% 0.51% 48'' SDMH #50 24.29 24.10 26.30 22.41 26.39 1.73%FOAM BETWEEN W AND SD3'-6"SCALE: 1"=20' HORIZ; 1"=5' VERT SDMH #28 TO CB #34 10 15 20 25 30 35 40 45 10 15 20 25 30 35 40 45 1+00 1+20 1+40 1+60 1+80 2+00 63 LF 8" DI SD @ SLP=0.51% 29 LF 12" DI SD @ SLP=1.43% 48'' SDMH #28 IE(IN)12"(S)=32.72 IE(OUT)12"(W)=32.19 STA C21+98, 17' LT RIM=35.51 60'' SDMH #29 IE(IN)8"(SE)=33.23 IE(IN)6"(E)=33.21 IE(OUT)12"(N)=33.13 STA C21+96, 12' RT RIM=35.74 CB #34 IE(OUT)8"(NW)=33.55 RIM=35.16EXIST 4"GEXIST 2"GEXIST 6"TEXIST 2"UGPEXIST UGPPROP 24"SSPROP 12"WEXIST 12"W0.33% 33.11 32.38 RIM=35.38 RIM=35.97 SCALE: 1"=20' HORIZ; 1"=5' VERT SDMH #29 TO CB #35 10 15 20 25 30 35 40 45 10 15 20 25 30 35 40 45 1+00 1+20 1+40 1+60 1+80EXIST 4"GPROP 12"WEXIST W(ABAN)EXIST G6" CONC SD (EXIST) 60'' SDMH #29 IE(IN)8"(SE)=33.23 IE(IN)6"(E)=33.21 IE(OUT)12"(N)=33.13 STA C21+96, 12' RT RIM=35.74 CB #35 IE(OUT)6"(W)=33.52 RIM=35.45EXIST 6"T64 LF 12" DI SD @ SLP=0.50% IE(OUT)12"(W)=33.53 IE(IN)6"(NE)=32.64 EXIST CB AND PIPE LEFT IN PLACE CB 73854 (EXIST) SCALE: 1"=20' HORIZ; 1"=5' VERT CB #37 TO SDMH #49 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 1+00 1+20 1+40 1+60 36 LF 12" PP SD @ SLP=7.92% CB #37 IE(OUT)12"(E)=27.59 RIM=30.89 48'' SDMH #30 IE(IN)18"(N)=22.76 IE(IN)12"(W)=27.44 IE(IN)12"(E)=23.48 IE(OUT)18"(S)=22.82 STA F2+53, 15' RT RIM=31.31 CB #74 IE(OUT)12"(W)=26.34 RIM=30.99PROP 8"SS &EXIST 10"SSPROP 12"WEXIST 8"W(ABAN)7 LF 12" PP SD @ SLP=2.17%EXIST 3"TEXIST T DUCT0.50% 27.78 27.70 23.61 RIM=31.14 48'' SDMH #49 23.80 4 LF 1.97%3'-6"FOAM BETWEEN W AND SD SCALE: 1"=20' HORIZ; 1"=5' VERT CB #42 TO EXIST CB #69591 0 5 10 15 20 25 30 35 0 5 10 15 20 25 30 35 1+00 1+20 1+40 1+60 1+80EXIST 2"GEXIST 12"SD(ABAN)EXIST 8"SSEXIST 12"WEXIST 3"TEXIST T DUCT33 LF 12" C900 @ SLP=5.07% EXIST CB #69591 IE(IN)6"(N)=28.55 IE(IN)4"(E)=28.75 IE(OUT)12"(S)=28.70 RIM=30.75 48'' SDMH #56 IE(IN)12"(N)=28.60 IE(IN)4"(SE)=29.00 IE(OUT)12"(W)=25.33 RIM=30.24 48'' SDMH #33 IE(IN)24"(N)=20.49 IE(IN)12"(W)=25.07 IE(IN)12"(E)=23.64 IE(OUT)24"(S)=20.46 STA F7+70, 12' RT RIM=30.70 CB #42 IE(OUT)12"(E)=25.07 RIM=30.22 9 LF 12" PP SD @ SLP=0.00% 13 LF 12" DI SD @ SLP=0.77% (EXIST) (RECONNECT) PLACE DENSE FOAM PER THE SPECS BETW SD & W AS DIRECTED BY THE ENGINEER (RECONNECT) 0.51% 23.80 20.63 25.14 20.63 STA F7+67, 14' RT 25.22 1.09% SCALE: 1"=20' HORIZ; 1"=5' VERT SDMH #32 TO SDMH #51 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 1+00 1+20 1+40 1+60 CB #76 IE(OUT)12"(W)=26.33 RIM=31.32 36 LF 12" PP SD @ SLP=6.20% 48'' SDMH #32 IE(IN)18"(N)=22.01 IE(IN)12"(W)=22.97 IE(IN)12"(E)=24.08 IE(OUT)18"(S)=22.00 STA F4+47, 15' RT RIM=31.67PROP 8"SS &EXIST 10"SSPROP 12"WEXIST 3"TEXIST T DUCTEXIST 8"W(ABAN)(RECONNECT) 48'' SDMH #51 24.45 RIM=31.61 0.50% 22.18 23.20 24.26 22.18 RIM=31.84 FOAM BETWEEN W AND SD3'-6"SCALE: 1"=20' HORIZ; 1"=5' VERT CB #17 TO EXIST SDMH #26853 0 5 10 15 20 25 30 35 0 5 10 15 20 25 30 35 0+80 1+00 1+20 1+40 1+60 EXIST SDMH #26853 IE(IN)12"(S)=22.10 IE(IN)12"(N)=27.40 IE(IN)12"(S)=25.20 IE(IN)4"(SE)=28.10 IE(OUT)12"(N)=23.48 STA F6+11, 17' RT RIM=31.45 22 LF 12" DI SD @ SLP=7.56% 48'' SDMH #14 IE(IN)18"(N)=21.76 IE(IN)12"(S)=21.85 IE(IN)12"(NW)=27.09 IE(OUT)18"(SE)=21.76 STA F5+89, 16' RT RIM=31.03 CB #17 IE(OUT)12"(SE)=27.28 RIM=30.72 6 LF 12" PP SD @ SLP=3.06%EXIST UGP(ABAN) 7.63% 21.72 26.80 1.00% (ABAN) SCALE: 1"=20' HORIZ; 1"=5' VERT CB #44 TO SDMH #34 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 1+00 1+20 1+40 1+60 60'' SDMH #34 IE(IN)24"(N)=19.46 IE(IN)12"(NW)=26.98 IE(IN)12"(E)=22.85 IE(IN)12"(S)=26.19 IE(OUT)24"(S)=19.46 STA F9+24, 15' RT RIM=30.65EXIST TEXIST 2"GEXIST 12"SD (ABAN)CB #44 RIM=29.71 33 LF 12" PP SD @ SLP=2.10%EXIST UGP(EXIST) EXIST CB LEFT IN SERVICE 20.10 24.40 23.50 IE(IN)12"(NE)=24.09 20.10 RIM=30.81 24.69 1.00% 26.84 18-2251 SD-42 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET LATERAL DRAINAGE PROFILES - 3 SEO BAW TTT 41NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SD-LATERALS-R.dwg SD-42 11/10/2023 12:05 PM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 75754647454 SD-15 1 SD-10 3 SD-15 2 SD-10 767675565 SD-15 6 SD-16 7 SD-16 868 SD-16454687RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS SCALE: 1"=20' HORIZ; 1"=5' VERT CB #46 TO SDMH #52 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 1+00 1+20 1+40 1+60 1+80 2+00EXIST UGPEXIST 10"SSEXIST 12"WEXIST T (2)EXIST UGPEXIST TEXIST 12"SD (ABAN)EXIST 16"W38 LF 12" DI SD @ SLP=4.00% 34 LF 12"C900 SD @ SLP=3.97% CB #46 IE(OUT)12"(N)=27.70 RIM=29.74 60'' SDMH #34 IE(IN)24"(N)=19.46 IE(IN)12"(NW)=26.98 IE(IN)12"(E)=22.85 IE(IN)12"(S)=26.19 IE(OUT)24"(S)=19.46 STA F9+24, 15' RT RIM=30.65 CB #43 IE(OUT)12"(W)=24.18 RIM=29.78 (NW)=26.98 0.76% 0.50% 27.13 20.10 24.40 23.50 26.84 20.10 RIM=30.81 CHANGED TO TYPE 1 CB RIM=29.94 48'' SDMH #52 42 LF 24.30 IE(IN)12"(NE)=24.09 SCALE: 1"=20' HORIZ; 1"=5' VERT SDMH #35 TO SDMH #53 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 1+00 1+20 1+40EXIST 16"WEXIST TEXIST TEXIST UGPEXIST 10"SS33 LF 12" PP SD @ SLP=1.76% CB #53 IE(OUT)12"(W)=20.65 RIM=29.67 48'' SDMH #35 IE(IN)24"(N)=19.60 IE(IN)12"(E)=20.06 IE(OUT)24"(S)=19.58 STA F10+01, 15' RT RIM=30.13 32 LF 12" PP SD @ SLP=0.50% 20.40 19.84 20.24 19.84 RIM=30.26 SCALE: 1"=20' HORIZ; 1"=5' VERT CB #50 TO CB #52 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 1+00 1+20 1+40 1+60EXIST 12"WCB #52 IE(OUT)12"(N)=27.70 RIM=28.97 33 LF 12" DI SD @ SLP=5.86% 19 LF 12" PP SD @ SLP=5.74%EXIST 2"G(ABANDONED)48'' SDMH #37 IE(IN)12"(S)=25.77 IE(IN)12"(N)=26.50 IE(IN)12"(E)=24.57 IE(OUT)18"(W)=19.59 STA F12+04, 30' LT RIM=29.87 CB #50 IE(OUT)12"(S)=27.59 RIM=29.14 EXIST 2"G26.83 0.50% 0.50% 26.65 25.91 19.75 36' LT 26.01 RIM=29.01 SCALE: 1"=20' HORIZ; 1"=5' VERT CB #54 TO SDMH #55 0 5 10 15 20 25 30 35 0 5 10 15 20 25 30 35 1+00 1+20 1+40 1+60EXIST 16"WEXIST TEXIST 12"SSEXIST 12"SD(REMOVED)34 LF 12"C900 SD @ SLP=5.77% CB #55 N IE(OUT)12"(W)=23.67 RIM=28.65 60'' SDMH #40 IE(IN)36"(N)=18.49 IE(IN)12"(W)=23.93 IE(IN)12"(E)=21.69 IE(OUT)36"(S)=18.48 STA F13+64, 14' RT RIM=29.39 CB #54 IE(OUT)12"(E)=24.59 RIM=28.79 8 LF 12" PP SD @ SLP=8.53% 0.51% 48'' SDMH #55 21.83 18.78 23.60 18.78 RIM=29.55 23.76 2.00%DI CHANGED TO TYPE 1 CB SCALE: 1"=20' HORIZ; 1"=5' VERT CB #56 TO CB #55 0 5 10 15 20 25 30 35 0 5 10 15 20 25 30 35 1+00 1+20 1+40 1+60EXIST TEXIST 12"SSEXIST 16"WEXIST 12"SD (ABAN)60'' SDMH #41 IE(IN)36"(N)=18.26 IE(IN)12"(W)=22.76 IE(IN)8"(E)=26.21 IE(OUT)36"(S)=18.21 STA F15+14, 11' RT RIM=28.76 CB #56 IE(OUT)12"(E)=23.30 RIM=28.21 CB #55 IE(OUT)8"(W)=26.70 RIM=28.17 32 LF 8" DI SD @ SLP=1.55% 11 LF 12" PP SD @ SLP=5.13% 18.41 STA F15+11, 13' RT RIM=28.93 26.35 0.50% 8 LF 4.83% 26.18 22.91 18.41 SCALE: 1"=20' HORIZ; 1"=5' VERT CB #59 TO CB #57 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 1+00 1+20 1+40 1+60 CB #57 IE(OUT)12"(W)=30.39 RIM=32.56 CB #59 IE(OUT)8"(NE)=30.40 RIM=32.45 6 LF 12" PP SD @ SLP=2.71% 41 LF 8" DI SD @ SLP=0.39% CB #58 IE(IN)8"(SW)=30.24 IE(IN)12"(E)=30.24 IE(OUT)12"(S)=27.44 RIM=32.79EXIST 1.25"G(ABANDONED)EXIST 12"WPROP 8" SSIE=18.2EXIST 2"G29.00 RIM=32.63 1.00% 0.31% 30.51 30.38 28.95 27.72 SCALE: 1"=20' HORIZ; 1"=5' VERT CB #49 TO SDMH #54 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 1+00 1+20 1+40 1+60EXIST 16"WEXIST TEXIST TEXIST 10"SSEXIST UGPEXIST 12"SD (ABAN)CB #49 IE(OUT)12"(E)=24.94 RIM=29.59 48'' SDMH #36 IE(IN)24"(N)=19.42 IE(IN)12"(E)=20.03 IE(IN)12"(W)=24.03 IE(OUT)24"(S)=19.37 STA F10+82, 12' RT RIM=30.04 48'' SDMH #54 IE(OUT)12"(W)=20.44 RIM=29.52 31 LF 12" PP SD @ SLP=1.34% 9 LF 12" PP SD @ SLP=10.08% 24.63 19.57 24.45 19.57 20.25 0.50% 2.26% SCALE: 1"=20' HORIZ; 1"=5' VERT CB #51 TO SDMH #37 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 1+00 1+20 1+40 1+60 1+70EXIST TEXIST TEXIST 10"SSEXIST UGPEXIST 2"G60'' SDMH #38 IE(IN)24"(N)=19.17 IE(IN)18"(E)=19.21 IE(IN)12"(W)=21.55 IE(IN)18"(N)=21.58 IE(OUT)24"(S)=19.27 STA F12+04, 16' RT RIM=29.54 CB #51 IE(OUT)12"(E)=24.53 RIM=29.18 48'' SDMH #37 IE(IN)12"(S)=25.77 IE(IN)12"(N)=26.50 IE(IN)12"(E)=24.57 IE(OUT)18"(W)=19.59 RIM=29.87 46 LF 18" PP SD @ SLP=0.83% (NW)=21.58 (RECONNECT)EXIST 16"W5 LF 12"PP SD @ SLP=57.54% 19.48 24.27 22.00 19.15 RIM=29.71 24.28 26.65 25.91 19.75 52 LF 0.25% 0.50% 18-2251 SD-43 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET LATERAL DRAINAGE PROFILES - 4 JAM BAW TTT 42NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SD-LATERALS-R.dwg SD-43 11/10/2023 12:05 PM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 177 772 SD-16 1 SD-16 7711771177778 SD-19 7 SD-18 6 SD-17 3 SD-17 4 SD-17 5 SD-1788 8838RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS EXISTING CB LEFT IN SERVICE SCALE: 1"=20' HORIZ; 1"=5' VERT CB #63 TO CB #62 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 1+00 1+20 1+40 1+60 CB #63 IE(OUT)12"(E)=27.28 RIM=33.08 48'' SDMH #45 IE(IN)12"(E)=27.27 IE(IN)12"(W)=27.02 IE(OUT)12"(S)=26.97 STA H3+63, 13' LT RIM=33.22 CB #62 IE(OUT)12"(W)=27.50 RIM=32.97 32 LF 12" DI SD @ SLP=0.81% 6 LF 12" PP SD @ SLP=3.63%EXIST 12"WEXIST 6"SD(REMOVE)EXIST 2"G30.60 27.67 30.43 27.19 STA H3+59 28.00 34 LF 5.00% 0.49% SCALE: 1"=20' HORIZ; 1"=5' VERT CB #64 TO SDMH #46 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 1+00 1+20 1+40PROP 8"SSEXIST 12"WEXIST 6"SD(REMOVE)EXIST 2"G34 LF 12" DI SD @ SLP=3.40% 48'' SDMH #46 IE(IN)12"(N)=26.87 IE(IN)12"(W)=29.52 IE(OUT)12"(S)=26.77 STA H4+10, 15' LT RIM=33.22 CB #64 IE(IN)4"(W)=31.62(RECONNECT) IE(OUT)12"(E)=30.67 RIM=33.07 0.51% 30.73 RIM=33.35 30.90 31.90 SCALE: 1"=20' HORIZ; 1"=5' VERT CB #29 TO CB #30 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 1+00 1+20 1+40 1+60PROP 8"SSEXIST 2"GEXIST 12"WEXIST 6"SD(REMOVE)34 LF 12" DI SD @ SLP=0.63% 5 LF 12" PP SD @ SLP=17.75% CB #29 IE(OUT)12"(E)=30.03 RIM=33.16 48'' SDMH #24 IE(IN)12"(N)=26.37 IE(IN)12"(W)=29.82 IE(IN)12"(E)=27.11 IE(OUT)12"(S)=26.27 STA H4+85, 14' LT RIM=33.11 CB #30 IE(OUT)12"(W)=27.96 RIM=32.82 0.52%5.00% 31.20 26.56 31.03 27.49 26.56 RIM=33.29 27.81 SCALE: 1"=20' HORIZ; 1"=5' VERT CB #66 TO CB #67 20 25 30 35 40 45 50 55 20 25 30 35 40 45 50 55 1+00 1+20 1+40 1+60 CB #66 IE(IN)12"(E)=41.24 IE(OUT)12"(N)=40.11 STA L4+60, 17' RT RIM=45.02 CB #67 IE(IN)12"(S)=41.50 IE(OUT)12"(W)=41.49 STA L4+61, 15' LT RIM=45.03 32 LF 12" PP SD @ SLP=0.78%PROP 12"WEXIST 66"W (SPU)PROP 12"CIPP SSEXIST G(ABAN BY OTHERS)41.40 41.40 0.52% SCALE: 1"=20' HORIZ; 1"=5' VERT CB #61 TO CB #60 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 1+00 1+20 1+401+42EXIST 1.25"GEXIST 12"WPROP 8"SS &EXIST 8"SS (REMOVE)30 LF 12" DI SD @ SLP=4.51%6 LF 12" PP SD @ SLP=4.12% CB #60 IE(OUT)12"(W)=27.16 RIM=32.30 48'' SDMH #44 IE(IN)12"(N)=26.49 IE(IN)12"(E)=26.93 IE(IN)12"(W)=29.28 IE(OUT)12"(S)=26.46 STA G4+10, 10' LT RIM=32.48 CB #61 IE(OUT)12"(E)=30.64 RIM=32.32 0.50%5.00% 27.10 30.24 26.59 RIM=32.67 30.39 SCALE: 1"=20' HORIZ; 1"=5' VERT CB #22 TO CB #23 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 1+00 1+20 1+35 CB #22 IE(OUT)12"(E)=30.13 RIM=32.13 48'' SDMH #20 IE(IN)12"(N)=24.80 IE(IN)12"(E)=27.03 IE(IN)12"(W)=29.77 IE(OUT)12"(S)=24.79 STA G5+19, 9' LT RIM=32.42 CB #23 IE(OUT)12"(W)=27.16 RIM=32.24 6 LF 12" PP SD @ SLP=2.11% 28 LF 12" DI SD @ SLP=1.28%EXIST 2"GEXIST 12"WPROP 8"SS &EXIST 8"SS (REMOVE)EXIST W (ABAN)27.14 29.99 RIM=32.61 0.51% 5.00% SCALE: 1"=20' HORIZ; 1"=5' VERT SDMH #48 TO CB #68 20 25 30 35 40 45 50 55 20 25 30 35 40 45 50 55 1+00 1+20 48'' SDMH #48 IE(IN)24"(W)=39.07 IE(IN)12"(S)=40.92 IE(IN)6"(SE)=39.12 IE(OUT)12"(E)=38.57 STA K3+55, 9' RT RIM=45.42 CB #68 IE(OUT)12"(N)=42.07 RIM=45.17 9 LF 12" PP SD @ SLP=12.96% (RECONNECT) 39.10 41.79 42.85 10.04% 38.80 SCALE: 1"=20' HORIZ; 1"=5' VERT CB #69 TO CB #71 20 25 30 35 40 45 50 55 20 25 30 35 40 45 50 55 1+00 1+20 1+40 1+60 1+80 CB #69 IE(IN)6"(SW)=42.49 IE(OUT)8"(S)=42.12 RIM=44.82 CB #70 IE(IN)8"(N)=41.98 IE(OUT)8"(E)=41.93 RIM=45.03 CB #71 IE(IN)12"(S)=42.04 IE(IN)8"(W)=41.87 IE(OUT)12"(N)=41.88 RIM=45.14 32 LF 8" C900 @ SLP=0.19%31 LF 8" DI SD @ SLP=0.46%PROP 12"WPROP 12"CIPP SSEXIST SIDE SEWEREXIST 66"W (SPU)(RECONNECT) 42.20 42.10 42.10 42.17 42.00 42.00 0.31%0.36% 18-2251 SD-44 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET LATERAL DRAINAGE PROFILES - 5 SEO BAW TTT 43NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SD-LATERALS-R.dwg SD-44 11/10/2023 12:05 PM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 63338666 SD-24 5 SD-21 4 SD-21 1 SD-20 2 SD-20 3 SD-21 8 SD-26 7 SD-24 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS SCALE: 1"=20' HORIZ; 1"=5' VERT CB #72 TO CB #73 20 25 30 35 40 45 50 55 20 25 30 35 40 45 50 55 1+00 1+20 1+40 1+60 32 LF 8" C900 @ SLP=0.66% CB #72 IE(OUT)8"(E)=42.80 RIM=45.46 CB #73 IE(IN)8"(W)=42.59 IE(OUT)12"(N)=42.59 RIM=45.83PROP 12"WPROP 12"CIPP SSEXIST 66"W (SPU)C13+00F6+00 8" SDR 35 SS F6+00 C13+0012"DI W •••••••••••••••••••••••••••• 18-2251 SD-45 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET LATERAL DRAINAGE PROFILES - 6 SEO BAW TTT 44NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SD-LATERALS-R.dwg SD-45 11/10/2023 12:05 PM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 1 SD-26 SCALE: 1" = 5' S 3RD ST & SHATTUCK AVE S 2 SD-16 SHATTUCK AVE S 3RD STSDMH #15 SDMH #14 CB #17 18"P P S D 18"PP SD 18"PP SD SDMH #16 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••3 8 3 7 3 8 3 7 3 639383637 38 353 5 3436 35 34 35 34 3 3 32 31333231293030 31 3233 3 4 37384 2 41 40 39 FIRE LANE 35 CRPL#3 66" STL CRPL#1 66" STL CRPL#2 51.5" STL CRPL#3 66" STL CRPL#1 66" STL CRPL#2 51.5" STL CRPL#1 66" STL CRPL#2 51.5" STL CRPL#3 66" STL •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• •••••••••••••••••••••••••••••••••••••••••••••••••••••••• •••• •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 14 EXIST G 12"DI W 12"DI W12"DI W 12"DI W STA A0+00, 9' RT N3+00N4+00A0+00 A1+00 A2+00 A3+00 A4+00 8 " SD R 3 5 S S 8" C900 SS8" SDR 35 SS 8" C900 SS8" SDR 35 SSSTA A0+31, 30' LT SSMH #1 1-48" DIA MH STA A0+75, 18' RT SSMH #2 1-48" DIA MH STA A2+36, 16' RT SSMH #3 1-48" DIA MH 65 LF 8 " S D R 3 5 S S @ SLP = 4 . 0 % 15 20 25 30 35 40 45 50 15 20 25 30 35 40 45 50 A0+00 A0+20 A0+40 A0+60 A0+80 A1+00 A1+20 A1+40 A1+60 A1+80 A2+00 A2+20 A2+40 A2+60 A2+80 A3+00 A3+20 A3+40 A3+60 A3+80 A4+00 A4+20 A4+40 A4+60 A4+80 3.4% 339 62 30.00 16' RT 24.57 24.57 24.47EXIST GEXIST 24"SDIE=21.0EXIST UGPEXIST W& PROPPROTECT W/ DENSE FOAM CUSHIONEXIST UGP & TEXIST UGP & T32.64 28' LT 41.06 161 LF 8" SDR 3 5 S S @ S L P = 3 . 0 % 337 LF 8" C900 SS @ SLP=0.4% 4.3% SSMH #3 IE(IN)8"(W)=25.09 IE(IN)8"(N)=25.00 IE(OUT)8"(E)=24.83 STA A2+36, 16' RT RIM=33.78 SSMH #2 IE(IN)8"(NW)=30.06 IE(OUT)8"(E)=29.86 STA A0+75, 18' RT RIM=39.74 SSMH #1 IE(IN)8"(SW)=32.90 IE(OUT)8"(SE)=32.80 STA A0+31, 30' LT RIM=41.82 18-2251 SS-1 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 2ND ST SEWER PLAN & PROFILE STA A0+00 TO STA A4+80 JJM BAW TTT 50NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-1 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CL S 2ND ST MATCHLINE STA A4+80SEE SHEET SS-2MATCHLINE STA A4+80SEE SHEET SS-2RAINIER AVE S1.CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 2.PROPOSED SEWER MAY HAVE CONFLICT OR SEQUENCE CONSTRAINT WITH EXISTING UTILITY TO BE ABANDONED, CONTRACTOR SHALL TAKE APPROPRIATE MEASURES TO MAINTAIN THE FUNCTIONALITY OF THE EXISTING UTILITY UNTIL SUCH TIME AS IT CAN BE ABANDONED 3.REPLACE SURVEY MONUMENT PER CITY STD DETAIL H031 AS REQUIRED FOR CONSTRUCTION 4.NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, AND 106 5.NEW SANITARY SEWER PIPE PER CITY STD DETAIL 405 6.SIDE SEWER PER CITY STD DETAIL 406.1, 406.2, AND/OR 407, INSTALL CO IF SHOWN 7.CONNECT EXIST PIPE TO NEW PIPE W/ CPLG, SEE DETAIL 2, SHT SS-42 1 8 10 12 13 15 1 13 1 13 2 15 10 10 12 TYP SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 144 RAINIER AVE S A1+46 N:178687.07 E:1298388.43 100 S 2ND ST A3+26 N:178678.19 E:1298568.38 SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 101 S 2ND ST SEE SS-13 N: E: *SS NO. SPECIFIC TO THIS SHEET 1 28" CIPP SS1010 LAKE AVE S8 FOR CONTINUATION SEE SHEET SS-27 10 17181819SSMH #37 SEE SHT SS-27 10 SPU ROW 2 2 2 CITY ROW 2 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 144 100 CONC. MON. IN CASE RESTABLISHED PER DNR PERMIT 7373-18"T x 6"W IE=32.29 IE=25.48 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 31 31 31 31 32 32 3 3 32 32 32 31 32 32 32 NO PARKING FIRE LANE NO PARKINGNO PARKING FIRE LANENO PARKING FIRE LANESTOP NO PARKINGNO PARKINGNO PARKING FIRE LANE3 2 3231 CRPL#3 66" STL CRPL#2 51.5" STL CRPL#3 66" STL CRPL#1 66" STL •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••FO DUCT 12"DI W 12"DI W TS E7+00 E8+00 A5+00 A6+00 A7+00 A8+00 A9+00 8" C900 SS 8" C900 SS 8" SIDE SEWER2"PVC CONDUIT STA A5+73, 17' RT SSMH #4 1-48" DIA MH 10 15 20 25 30 35 40 45 10 15 20 25 30 35 40 45 A4+80 A5+00 A5+20 A5+40 A5+60 A5+80 A6+00 A6+20 A6+40 A6+60 A6+80 A7+00 A7+20 A7+40 A7+60 A7+80 A8+00 A8+20 A8+40 A8+60 A8+80 A9+00 A9+20 A9+40 A9+60 394 23.10 23.00 23.10 A5+75, 15' RTEXIST GEXIST TEXIST TEXIST UGPEXIST 12"SDIE=26.9EXIST TPROP 12"WEXIST UGPPROP FH396 LF 8" C900 SS @ SLP=0.4% IE(IN)8"(N)=23.48 SSMH #4 IE(IN)8"(W)=23.43 IE(OUT)8"(E)=23.27 STA A5+73, 17' RT RIM=30.86 18-2251 SS-2 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 2ND ST SEWER PLAN & PROFILE STA A4+80 TO STA A9+60 JJM BAW TTT 51NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-2 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CL S 2ND ST MATCHLINE STA A4+80SEE SHEET SS-1MATCHLINE STA A9+60SEE SHEET SS-3MATCHLINE STA A4+80SEE SHEET SS-1MATCHLINE STA A9+60SEE SHEET SS-310 12 TYP 1 8 2 SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 200 S 2ND ST A5+74 N:178672.65 E:1298816.39 203 S 2ND ST SEE SS-14 N: E: 1 SSMH 2146 10 1.CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 2.PROPOSED SEWER MAY HAVE CONFLICT OR SEQUENCE CONSTRAINT WITH EXISTING UTILITY TO BE ABANDONED, CONTRACTOR SHALL TAKE APPROPRIATE MEASURES TO MAINTAIN THE FUNCTIONALITY OF THE EXISTING UTILITY UNTIL SUCH TIME AS IT CAN BE ABANDONED 3.SPU CONDUIT AND APPURTENANCES SHALL BE INSTALLED FOR FUTURE CATHODIC PROTECTION SYSTEM (BY OTHERS), SEE DETAILS, SHT CP-2 4.REPLACE SURVEY MONUMENT PER CITY STD DETAIL H031 AS REQUIRED FOR CONSTRUCTION 5.NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, AND 106 6. NEW SANITARY SEWER PIPE PER CITY STD DETAIL 405 7.SIDE SEWER PER CITY STD DETAIL 406.1, 406.2, AND/OR 407 AND CO IF SHOWN 1 2 8 10 12 13 *SS NO. SPECIFIC TO THIS SHEET 131 8 PROTECT NEW WATER LINE AS NECESSARY DURING CONSTRUCTION 2223CONSTRUCT SIDE SEWER THROUGH ABANDONED VAULT, POTHOLE TO LOCATE NORTH/SOUTH LIMITS OF VAULT PRIOR TO CONSTRUCTION, PROVIDE SHORING IN VAULT AS NEEDED TO PREVENT VOIDS OR SETTLEMENT OF ROADWAY, COORDINATE SCHEDULE FOR THIS WORK WITH CITY 1' DEEP TO TOP OF VAULT CORE DRILLED FOR PIPE AT 6'-6" DEEP CITY PRO P E R T Y AT&T CRITICAL FIBER OPTIC PROTECT-IN-PLACE PER 1-07.17 SPU P R O P E R T Y CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' CITY ROW SPU P R O P E R T Y 4 TAP CONDUIT INTO EXIST SPU RECTIFIER STRUCTURE 4 400 211 CONC. MON. IN CASE REESTABLISHED PER DNR PERMIT 7373-18"T x 6"W CONC. MON. IN CASE REESTABLISHED PER DNR PERMIT 7373-18"T x 6"W RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••32 33 33 33 34 33 34 34 33 34 33 3333 32 NO PARKING FIRE LANECRPL #3 66" STL CRPL#3 66" STL CRPL#3 66" STL FO DUCT FO DUCT FO DUCT FO DUCT 8" D I S D8"PP SD 12"C900 SD 12"DI S D 15"PP SD 8"DI SD 8" D I S D 12"PP SD 8"DI SD8"DI W12"DI W12"DI W 12"DI W12"DI W TS TS TS TS TSG0+00A10+00 A11+00 A12+00 A13+00 A14+00 8" SDR 35 SS 8" C900 SS8" SDR 35 SS2"PVC CONDUIT STA A9+72, 12' LT SSMH #5 1-48" DIA MH STA A9+92, 27' RT CPMH #1 1-30" MH FRAME & COVER STA A10+90, 27' RT CPMH #2 1-30" MH FRAME & COVER STA A12+09, 26' RT CPMH #3 1-30" MH FRAME & COVER STA A13+24, 26' RT CPMH #4 1-30" MH FRAME & COVER STA A10+90, 17' RT CPJB #1 STA A12+09, 16' RT CPJB #2 STA A13+24, 19' RT CPJB #3 STA A12+87, 29' RT SSMH #4 1-48" DIA MH STA A9+75, 28' RT SSMH #6 1-48" DIA MH 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 A9+60 A9+80 A10+00 A10+20 A10+40 A10+60 A10+80 A11+00 A11+20 A11+40 A11+60 A11+80 A12+00 A12+20 A12+40 A12+60 A12+80 A13+00 A13+20 A13+40 A13+60 A13+80 A14+00 315 0.4% 331 1.6% 19.21 19.21 19.11 33.23 20.87 20.54 A9+72 32.09 EXIST WSEXIST UGPEXIST UGPEXIST UGPEXIST UGPEXIST WEXIST TPROP & EXIST WEXIST TPROP 12"W(BEHIND)PROP 12"SDIE=30.2EXIST UGPPROP 12"SDIE=30.2EXISTING MANHOLE KEPT IN PLACE SSMH #5 IE(IN)8"(W)=21.88 IE(OUT)15"(E)=21.23 STA A9+72, 12' LT RIM=32.31 312 LF 8" SDR 35 SS @ SLP=0.6% 328 LF 8" C900 SS @ SLP=1. 3 % 32.06 21.42 20.80 SSMH #6 IE(IN)8"(S)=21.65 IE(OUT)8"(E)=21.29 STA A9+75, 28' RT RIM=32.50 SSMH #7 IE(IN)8"(W)=19.50 IE(IN)8"(E)=19.45 IE(OUT)8"(S)=19.45 STA A12+87, 28' RT RIM=33.07 18-2251 SS-3 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 2ND ST SEWER PLAN & PROFILE STA A9+60 TO STA A14+00 JJM BAW TTT 52NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-3 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CL SSMH #26, SEE SHT SS-15 S 2ND ST MATCHLINE STA A9+60SEE SHEET SS-2MATCHLINE STA A14+00SEE SHEET SS-4MATCHLINE STA A9+60SEE SHEET SS-2MATCHLINE STA A14+00SEE SHEET SS-4WHITWORTHAVE SSHATTUCKAVE SFOR CONTINUATION SEE SHEET SS-19 1 12 TYP 10 10 10 SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 305 S 2ND ST SEE SS-15 N: E: 309 S 2ND ST SEE SS-15 N: E: 315 S 2ND ST SEE SS-15 N: E: SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 319 S 2ND ST SEE SS-15 N: E: 321 S 2ND ST SEE SS-15 N: E: 400 S 2ND ST NIC N: E: FOR CONTINUATION SEE SHEET SS-15 10 10 1.CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 2.SPU CONDUIT AND APPURTENANCES SHALL BE INSTALLED FOR FUTURE CATHODIC PROTECTION SYSTEM (BY OTHERS), SEE DETAILS, SHT CP-2 3.NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, AND 106 4.NEW SANITARY SEWER PIPE PER CITY STD DETAIL 405 5.CONNECT EXIST PIPE TO NEW PIPE W/ CPLG, SEE DETAIL 2, SHT SS-42 1 10 12 15 *SS NO. SPECIFIC TO THIS SHEET 15 8" C900 SS2526SPU PROPERTY AT&T CRITICAL FIBER OPTIC, PROTECT-IN-PLACE PER 1-07.17 CITY ROW SPU PROPERTY CITY ROW CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 4 4 321305 400 400 EXISTING SSMH KEPT IN PLACE RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS STA A9+72 15 25' RT 25' RT 17' RT 18' RT FOUND PREVIOUSLY UNKNOWN LUMEN FO DUCT •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••34 33 3 4 34 34 3535 35 36 36 3635 3534 34 333333 CRPL #3 66" STL CRPL #3 66" STL CRPL #3 66" STL ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••8"C900 SD 8"DI SD8"DI SD12"PP SD 8"DI SD8"C900 SD12"C900 SD8" C90 0 S SH0+00A14+00 A15+00 A16+00 A17+00 A18+00 8" C900 SS 8" C900 SS 8" SDR 35 SS2"PVC CONDUIT 2"PVC CONDUIT STA A14+07, 27' RT CPMH #5 1-30" MH FRAME & COVER STA A14+07, 18' RT CPJB #4 STA A15+25, 28' RT CPMH #6 1-30" MH FRAME & COVER STA A15+25, 18' RT CPJB #5 STA A16+38, 18' RT CPJB #6 STA A17+55, 17' RT CPMH #8 1-30" MH FRAME & COVER STA A17+51, 20' RT SSMH #9 1-48" DIA MH STA A17+82, 43' RT SSMH #10 1-48" DIA MH STA A16+39, 27' RT CPMH #7 1-30" MH FRAME & COVER STA A16+15, 29' RT SSMH #8 1-48" DIA MH STA A18+48, 53' RT 10 15 20 25 30 35 40 45 10 15 20 25 30 35 40 45 A14+00 A14+20 A14+40 A14+60 A14+80 A15+00 A15+20 A15+40 A15+60 A15+80 A16+00 A16+20 A16+40 A16+60 A16+80 A17+00 A17+20 A17+40 A17+60 A17+80 A18+00 A18+20 A18+40 A18+60 A18+80 136 LF 8" C900 SS @ S L P = 2 . 1 % 24.53 24.53 24.43 A16+18, 29' RTEXIST SS (TO BE ABAN)PROP & EXIST SDIE=30.4EXIST GEXIST WEXIST GEXIST UGP, T & COMEXIST UGP, T & COMEXIST WPROP 12"SDSTA A14+4034.74 26.97 26.87 A17+36, 24' SSMH #10 RIM=35.99 IE(IN)6"(S)=28.26 IE(OUT)8"(W)=27.99 115 LF 8" C900 SS @ SLP=0.9% 118 2.0% SSMH #9 39 LF 8" C900 SS @ SLP=1.5% SSMH #9 IE(IN)8"(SE)=26.75 IE(OUT)8"(W)=26.67 STA A17+51, 20' RT RIM=34.94 SSMH #10 IE(IN)6"(S)=27.69 IE(OUT)8"(NW)=27.34 STA A17+82, 43' RT RIM=35.32SSMH #8 IE(IN)8"(E)=23.83 IE(IN)8"(S)=23.81 IE(OUT)8"(W)=23.79 STA A16+15, 29' RT RIM=33.77 STA A16+18 18-2251 SS-4 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 2ND ST SEWER PLAN & PROFILE STA A14+00 TO STA A18+80 JJM BAW TTT 53NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-4 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CL S 2ND STMATCHLINE STA A14+00SEE SHEET SS-3MATCHLINE STA A14+00SEE SHEET SS-3MORRIS AVE SFOR CONTINUATON SEE SHEET SS-21 1 12 TYP 10 10 10 SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 419 S 2ND ST A14+31 N:178534.22 E:1299675.40 507 S 2ND ST SEE SS-21 N: E: SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 511 S 2ND ST A17+71 N:178535.75 E:1300002.42 513 S 2ND ST A17+82 SSMH #10 N:178539.10 E:1300016.18 1 2 3 1.CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 2.PROPOSED SEWER MAY HAVE CONFLICT OR SEQUENCE CONSTRAINT WITH EXISTING UTILITY TO BE ABANDONED, CONTRACTOR SHALL TAKE APPROPRIATE MEASURES TO MAINTAIN THE FUNCTIONALITY OF THE EXISTING UTILITY UNTIL SUCH TIME AS IT CAN BE ABANDONED 2.SPU CONDUIT AND APPURTENANCES SHALL BE INSTALLED FOR FUTURE CATHODIC PROTECTION SYSTEM (BY OTHERS), SEE DETAILS, SHT CP-2 3.NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, AND 106 4.NEW SANITARY SEWER PIPE PER CITY STD DETAIL 405 5.INSTALL SIDE SEWER PER CITY STD DETAIL 406.1, 406.2, AND/OR 407 AND CO IF SHOWN 1 2 10 12 13 *SS NO. SPECIFIC TO THIS SHEET 213 10 10 10 REMOVE BLOCK WALL 113 27282929SPU PROPERTY CITY ROW SPU PROPERTY CITY ROW 2 CONFIRM SIDE SEWER CO PRIOR TO CONSTRUCTION CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' CAP CONDUIT STUB MIN 2-FT BEYOND CPMH#8 4 4 4 419 507 511 513 COORDINATE CP STRUCTURE LOCATION WITH ENGINEER AS NEAR AS PRACTICAL TO THE EDGE OF RESTORATION EXTENTS RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS IE=27.23 IE=28.43 STA A18+48, 53' RT IE=30.69 STA A17+36, 24' RT STA A17+54, 21' RT STA A16+38, 26' RT STA A15+26 STA A15+26, 26' RT STA A14+10, 26' RT STA A14+10 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••37 37 37373737 37 38 3839 39 37 38 373937CRPL #3 66" STL CRPL #3 66" STL CRPL #3 66" STL•••••••••••••••••••••••••CRPL #3 66" STL 8"SS A23+40A20+00 A21+00 A22+00 A23+00 12" C900 SS8" C900 SS 2"PVC CONDUIT STA A19+95, 5' LT SSMH #11 1-48" DIA MH STA A23+25, 2' LT CPJB #8 STA A23+19, 7' LT SSMH #12 1-72" DIA MH STA A19+90, 2' LT CPJB #7 15 20 25 30 35 40 45 50 15 20 25 30 35 40 45 50 A19+20 A19+40 A19+60 A19+80 A20+00 A20+20 A20+40 A20+60 A20+80 A21+00 A21+20 A21+40 A21+60 A21+80 A22+00 A22+20 A22+40 A22+60 A22+80 A23+00 A23+20 A23+40 5' LT 30.20 37.22EXIST W (SPU)EXIST UGP, T & COMEXIST SS108" KC INTERCEPTORIE=4.0EXIST WEXIST UGPEXIST W324 LF 8" C900 SS @ SLP=0.5% 32.00 32.00 28.41 28.31 SSMH #11 IE(IN)8"(S)=30.09 IE(OUT)8"(E)=29.80 STA A19+95, 5' LT RIM=37.14 SSMH #12 IE(IN)8"(W)=28.25 IE(IN)12"(E)=31.90 IE(IN)8"(S)=31.90 IE(OUT)12"(N)=28.15 STA A23+19, 7' LT RIM=38.67 18-2251 SS-5 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 2ND ST SEWER PLAN & PROFILE STA A19+20 TO STA A23+40 JJM BAW TTT 54NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-5 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE 1 EXIST GR @ ROW CL SSMH #32, SEE SHT SS-22 S 2ND ST LOGAN AVE SBURNETT AVE S10 11 12 TYP KING COUNTY INTERCEPTOR TIE-IN, SEE DET SHT SS-40 SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 526 S 2ND ST NIC N: E: 205 LOGAN AVE S NIC N: E: SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 655 S 2ND AVE NIC N: E: 150 LOGAN AVE S NIC N: E: 1.CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 2.SPU CONDUIT AND APPURTENANCES SHALL BE INSTALLED FOR FUTURE CATHODIC PROTECTION SYSTEM (BY OTHERS), SEE DETAILS, SHT CP-2 3.REPLACE SURVEY MONUMENT PER CITY STD DETAIL H031 AS REQUIRED FOR CONSTRUCTION 4.NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, AND 106 5.NEW DROP SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, 402.2, AND 106 6.NEW SANITARY SEWER PIPE PER CITY STD DETAIL 405 7.CONNECT EXIST PIPE TO NEW PIPE W/ CPLG, SEE DETAIL 2, SHT SS-42 1 4 8 10 11 12 15 11 10 *SS NO. SPECIFIC TO THIS SHEET 15 15 8 PROTECT 12" SPU WATER IN PLACE, DO NOT ALLOW EXIST PEA GRAVEL BACKFILL TO UNRAVEL, BACKFILL PIPE BEDDING PER SPU STD PLAN 350 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 4 150 655 COORDINATE CP STRUCTURE LOCATION WITH ENGINEER AS NEAR AS PRACTICAL TO THE EDGE OF RESTORATION EXTENTS COORDINATE CP STRUCTURE LOCATION WITH ENGINEER AS NEAR AS PRACTICAL TO THE EDGE OF RESTORATION EXTENTS RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS CONC MON IN CASE REESTABLISHED PER DNR PERMIT 7373-18" T x 6" W #31 •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• •••••••••••••••••••••••••••••••• 33 32 34 33 32 31 30 323131••••••••••••••••••••••••••••••••••••••••••••••••• •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••STA C3+06, 4' RT SSMH #14 1-60" DIA MH STA C2+53, 21' RT CULVERT ACCESS VAULT, SEE SHT SD-51 STA C1+82, 31' LT SSMH #38 1-48" DIA MH STA C2+56, 37' LT SSMH #13 1-60" DIA MH C0+00 C1+00 C2+00 C3+00 C4+00 E0+0 0 18" C900 SS 2 4 " C 9 0 0 S S 24" C900 SS SAN SWR-ALIGN C 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 C0+00 C0+20 C0+40 C0+60 C0+80 C1+00 C1+20 C1+40 C1+60 C1+80 C2+00 C2+20 C2+40 C2+60 C2+80 C3+00 C3+20 C3+40 C3+60 C3+80 C4+00 C4+20 C4+40 C4+60 C4+80EXIST WEXIST FOEXIST WEXIST GEXIST WEXIST FOEXIST TEXIST TVEXIST GASEXIST UGP80 LF 18" PVC SS @ S L P = 1 . 9 %65 LF 279 LF 24" PVC SS @ SLP=1.1% 32.67 STA C1+82 STA C2+56, 37' LT 32.19 23.93 25.50 (ABAN) 4' RT 31.95 74 LF 18" PVC SS @ S L P = 2 . 0 % 62 LF 24" PVC SS @ SLP=1.6% SSMH #38 IE(IN)12"(W)=26.50 IE(OUT)18"(E)=25.40 STA C1+83, 31' LT RIM=32.32 SSMH #14 IE(IN)24"(NW)=22.45 IE(OUT)24"(E)=22.37 STA C3+06, 6' RT RIM=31.79 SSMH #13 IE(IN)18"(W)=23.90 IE(IN)8"(N)=25.45 IE(OUT)24"(SE)=23.45 IE(OUT)12"(E)=25.50 STA C2+62, 38' LT RIM=31.95 18-2251 SS-6 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 3RD ST SEWER PLAN & PROFILE STA C0+00 TO STA C4+80 JJM BAW TTT 55NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-6 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE 30" CL 50 DI PIPE CASING WITH ZINC COATING THROUGH CULVERT, SEE SHT SD-54 S 3RD ST MATCHLINE STA C4+80SEE SHEET SS-7MATCHLINE STA C4+80SEE SHEET SS-7RAINIERAVE SSW SUNSET BLV D 15 1 12 TYP 10 SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 275 RAINIER AVE S NIC N: E: 101 SW SUNSET BLVD NIC N: E: SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 53 SW SUNSET BLVD NIC N: E: 307 RAINIER AVE S NIC N: E: SSMH 2183 EXIST GR @ ROW CL 1.CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 2.NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, AND 106 3.NEW SANITARY SEWER PIPE PER CITY STD DETAIL 400.1, 405, AND 106 4.CONNECT EXIST PIPE TO NEW PIPE W/ CPLG, SEE DETAIL 2, SHT SS-42 1 10 12 15 10 *SS NO. SPECIFIC TO THIS SHEET FOR CONTINUATION SEE SHEET SS-28 10 10 303115 10 10 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 60 275 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS STA C2+83, 1' RT ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••32 32 3131 32 32 32 32 32STOP12"C900 SD 12"C900 SD 12"C900 SD 12"C900 SD STA C5+85, 6' RT SSMH #15 1-60" DIA MH C5+00 C6+00 C7+00 C8+00 C9+00 24" C900 SS24" C900 SS 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 C4+80 C5+00 C5+20 C5+40 C5+60 C5+80 C6+00 C6+20 C6+40 C6+60 C6+80 C7+00 C7+20 C7+40 C7+60 C7+80 C8+00 C8+20 C8+40 C8+60 C8+80 C9+00 C9+20 C9+40 C9+60 542 19.11 31.48 EXIST WEXIST WSEXIST UGPEXIST WSEXIST WSEXIST WSEXIST WSEXIST WSEXIST SDEXIST 12" SDIE=22.9EXIST SDEXIST UGP538 LF 24" C900 SS @ SLP=0.1% SSMH #15 IE(IN)24"(W)=19.28 IE(OUT)24"(E)=19.01 STA C5+85, 6' RT RIM=31.32 18-2251 SS-7 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 3RD ST SEWER PLAN & PROFILE STA C4+80 TO STA C9+60 JJM BAW TTT 56NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-7 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE 1 EXIST GR @ ROW CL S 3RD ST MATCHLINE STA C4+80SEE SHEET SS-6MATCHLINE STA C9+60SEE SHEET SS-8MATCHLINE STA C4+80SEE SHEET SS-6MATCHLINE STA A9+60SEE SHEET SS-8FOR CONTINUATION SEE SHEET SS-12 12 TYP 10 SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 300 RAINIER AVE S NIC N: E: 107 S 3RD ST NIC N: E: SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 111 S 3RD ST NIC N: E: 125 S 3RD ST NIC N: E: COORDINATE WITH GAS UTILITY 1.CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 2.NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, AND 106 3.NEW SANITARY SEWER PIPE PER CITY STD DETAIL 405 1 10 12 10 *SS NO. SPECIFIC TO THIS SHEET CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 250 112 112 112 300 107 111 115 125 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••32 31 31 313218" PP SD18" PP SD 18" PP SD 24" PP SD18" PP SD12"P P S D12"DI WSTA C11+22, 6' RT SSMH #17 1-60" DIA MH STA C12+73, 6' RT SSMH #18 1-60" DIA MH C10+00 C11+00 C12+00 C13+00 C14+00 24" C900 SS 8" SDR 35 SS8" SDR 35 SS24" C900 SS 24" C900 SS 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 C9+60 C9+80 C10+00 C10+20 C10+40 C10+60 C10+80 C11+00 C11+20 C11+40 C11+60 C11+80 C12+00 C12+20 C12+40 C12+60 C12+80 C13+00 C13+20 C13+40 C13+60 C13+80 C14+00 C14+20 C14+40 18.37 23.37 STA C11+28, 5' RT 31.38 17.87 17.77 147 318EXIST SDEXIST GEXIST WSEXIST WSEXIST WSEXIST 12"SDIE=27.6EXIST GEXIST UGPEXIST UGPEXIST 12"SDIE=22.1EXIST WCL=24.95EXIST TEXIST TEXIST UGPEXIST 12"SDIE=28.1PROP 18"SDIE=21.7PROP 18"SDIE=22.4151 LF 24" C900 SS @ SLP=0.4% 314 LF 24" PVC SS @ SLP=0.5% 0.7% 0.3%SSMH #17 IE(IN)24"(W)=18.43 IE(IN)8"(N)=23.26 IE(OUT)24"(E)=18.26 STA C11+22, 6' RT RIM=31.27 SSMH #18 IE(IN)8"(N)=19.29 IE(IN)24"(W)=17.70 IE(OUT)24"(E)=17.48 STA C12+73, 6' RT RIM=31.21 SHATTUCK AVE S18-2251 SS-8 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 3RD ST SEWER PLAN & PROFILE STA C9+60 TO STA C14+40 JJM BAW TTT 57NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-8 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE 12 EXIST GR @ ROW CL S 3RD ST MATCHLINE STA C9+60SEE SHEET SS-7MATCHLINE STA C14+40SEE SHEET SS-9MATCHLINE STA C9+60SEE SHEET SS-7MATCHLINE STA C14+40SEE SHEET SS-91 14 FOR CONTINUATION SEE SHEET SS-15 TYP 11 10 SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 200 S 3RD ST SSMH 5205 N: E: 201 S 3RD ST NIC N: E: 205 S 3RD ST NIC N: E: SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 207 S 3RD ST NIC N: E: 301 S 3RD ST NIC N: E: 305 S 3RD ST NIC N: E: SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 309 S 3RD ST NIC N: E: 1.CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 2.REPLACE SURVEY MONUMENT PER CITY STD DETAIL H031 AS REQUIRED FOR CONSTRUCTION 3.NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, AND 106 4.NEW DROP SSMH AS SHOWN PER CITY STD DETAIL 400.0, 401, 402.2, AND 106 5.NEW SANITARY SEWER PIPE PER CITY STD DETAIL 405 6.GROUT NEW PIPE INTO EXIST SSMH W/ SANDED ADAPTER AND RE-CHANNEL SSMH, SEE DETAIL 1, SHT SS-42 1 8 10 11 12 14 10 11 *SS NO. SPECIFIC TO THIS SHEET 8 32AT&T CRITICAL FIBER OPTIC, PROTECT-IN-PLACE PER 1-07.17 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 200 200 212 300 201 205 207 305 309 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS 28, 5'23 LFCONC. MON. IN CASE REESTABLISHED PER DNR PERMIT 7373-18"T x 6"W ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••33 33 33 33 34 343318" PP SD 18" PP SD18" PP SD 18" PP SD12" PP SD12"DI SD12"D I SD12"DI SD12"DI SD12"DI SD 12"DI WSTA C15+87, 6' RT SSMH #19 1-60" DIA MH C15+00 C16+00 C17+00 C18+00 24" C900 SS 24" C900 SS8" C900 SS24" C900 SS 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 C14+40 C14+60 C14+80 C15+00 C15+20 C15+40 C15+60 C15+80 C16+00 C16+20 C16+40 C16+60 C16+80 C17+00 C17+20 C17+40 C17+60 C17+80 C18+00 C18+20 C18+40 C18+60 C18+80 15.56 16.90 15.46 STA C15+92, 5' RT RIM=33.11 305EXIST WSEXIST WSEXIST WEXIST GPROP WEXIST W(TO BE ABAN)EXIST & PROP SDEXIST WSEXIST GEXIST WSEXIST UGPPROP 12"SDIE=29.5PROP 12"SDIE=25.6PROP 18"SDIE=26.1312 LF 24" C900 SS @ SLP=0.1% SSMH #19 IE(IN)24"(W)=15.94 IE(IN)8"(N)=16.79 IE(OUT)24"(E)=15.64 STA C15+87, 6' RT RIM=32.94WHITWORTH AVE S18-2251 SS-9 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 3RD ST SEWER PLAN & PROFILE STA C14+40 TO STA C18+80 JJM BAW TTT 58NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-9 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CL S 3RD ST1 MATCHLINE STA C14+40SEE SHEET SS-8MATCHLINE STA C18+80SEE SHEET SS-10MATCHLINE STA C14+40SEE SHEET SS-8MATCHLINE STA C18+80SEE SHEET SS-10FOR CONTINUATION SEE SHEET SS-20 12 TYP 10 SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 316 S 3RD ST C15+10 N:178072.38 E:1299433.34 322 S 3RD ST C15+17 N:178071.93 E:1299438.33 315 S 3RD ST NIC N: E: SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 319 S 3RD ST NIC N: E: 321 S 3RD ST NIC N: E: 325 S 3RD ST NIC N: E: SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 400 S 3RD ST SEE SS-20 N: E: 401 S 3RD ST NIC N: E: 405 S 3RD ST NIC N: E: SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 410 S 3RD ST NIC N: E: 413 S 3RD ST NIC N: E: 415 S 3RD ST NIC N: E: SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 422 S 3RD ST NIC N: E: 423 S 3RD ST NIC N: E: 1 2 1.CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 2.NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, AND 106 3.NEW SANITARY SEWER PIPE PER CITY STD DETAIL 405 4.INSTALL SIDE SEWER PER CITY STD DETAIL 406.1, 406.2, AND/OR 407 AND CO IF SHOWN 1 10 12 13 10 *SS NO. SPECIFIC TO THIS SHEET 13 2 13 1 8" C900 SS33CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 316 400 410 422 315 319 321 325 401 405 413 415 423 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS 92, 5' IE:25.70 IE:26.26 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••34 34 35 35 35 3636 363612" PP SD 12" C900 SD18" PP SD 12"DI SD12" PP SD12" PP SD6" SD 12"DI SD 12"DI SD8 " D I SD 12" DI S D STA C18+99, 8' RT SSMH #20 1-48" DIA MH C19+00 C20+00 C21+00 C22+00 C23+00 24" C900 SS 24" C900 SS8" SDR 35 SS24" C900 SS 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 C18+80 C19+00 C19+20 C19+40 C19+60 C19+80 C20+00 C20+20 C20+40 C20+60 C20+80 C21+00 C21+20 C21+40 C21+60 C21+80 C22+00 C22+20 C22+40 C22+60 C22+80 C23+00 C23+20 C23+40 C23+60 606EXIST UGPEXIST TEXIST UGPEXIST WSEXIST WSEXIST GEXIST WSEXIST W(TO BE ABAN)PROP WEXIST GEXIST TEXIST UGPEXIST UGPPROP 12"SDIE=33.2EXIST & PROP SDEXIST WEXIST G15.16 15.06 STA C18+97, 7' RT 33.84 PROP 12"SDIE=30.0603 LF 24" C900 SS @ SLP=0.1% SSMH #20 IE(IN)24"(W)=15.34 IE(IN)8"(N)=23.58 IE(OUT)24"(E)=15.27 STA C18+99, 8' RT RIM=33.66MORRIS AVE S18-2251 SS-10 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 3RD ST SEWER PLAN & PROFILE STA C18+80 TO STA C23+60 JJM BAW TTT 59NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-10 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CL S 3RD ST MATCHLINE STA C18+80SEE SHEET SS-9MATCHLINE STA C23+60SEE SHEET SS-11MATCHLINE STA C18+80SEE SHEET SS-9MATCHLINE STA C23+60SEE SHEET SS-11LOGAN AVE S1 12 TYP SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 280 MORRIS AVE S SEE SS-21 N: E: 503 S 3RD ST NIC N: E: 504 S 3RD ST SEE SS-21 N: E: SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 505 S 3RD ST NIC N: E: 507 S 3RD ST NIC N: E: 509 S 3RD ST NIC N: E: SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 601 S 3RD ST NIC N: E: 613 S 3RD ST NIC N: E: 1.CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 2.REPLACE SURVEY MONUMENT PER CITY STD DETAIL H031 AS REQUIRED FOR CONSTRUCTION 3.NEW DROP SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, 402.2 AND 106 4.NEW SANITARY SEWER PIPE PER CITY STD DETAIL 405 1 8 11 12 SMITHERSAVE S*SS NO. SPECIFIC TO THIS SHEET 11 11 88" SDR 35 SS3480CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 505 507 509 601 280 504 510 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS CONC. MON. IN CASE REESTABLISHED PER DNR PERMIT 7373-18"T x 6"W CONC. MON. IN CASE REESTABLISHED PER DNR PERMIT 7373-18"T x 6"W ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••37 37 38 3839 CRPL # 3 6 6 " S T L CRPL # 2 5 1 . 5 " S T L STA C25+03, 5' RT SSMH #22 DROP 1-72" DIA MH SEE DET 1, SHT SS-41 C24+00 C25+00 C26+00 C26+15 -5 0 5 10 15 20 25 30 35 40 -5 0 5 10 15 20 25 30 35 40 C23+60 C23+80 C24+00 C24+20 C24+40 C24+60 C24+80 C25+00 C25+20 C25+40 C25+60 C25+80 C26+00 14.72 37.86EXIST WS2.0%EXIST G43 LF 24" PVC SS @ SLP=1.9% SSMH KCMH R01-17 IE(IN)24"(NW)=8.50 IE(OUT)108"(S)=4.00 STA A22+35, 590' RT RIM=38.14 SSMH #22 IE(IN)24"(W)=14.40 IE(OUT)24"(SE)=9.29 STA C25+03, 5' RT RIM=37.75 BURNETT AVE S18-2251 SS-11 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 3RD ST SEWER PLAN & PROFILE STA C23+60 TO STA C26+15 JJM BAW TTT 60NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-11 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE 1 EXIST GR @ ROW CL S 3RD ST MATCHLINE STA C23+60SEE SHEET SS-10MATCHLINE STA C23+60SEE SHEET SS-1012 TYP SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 617 S 3RD ST NIC N: E: 700 S 3RD ST NIC N: E: 300 BURNETT AVE S NIC N: E: 1.CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 2.REPLACE SURVEY MONUMENT PER CITY STD DETAIL H031 AS REQUIRED FOR CONSTRUCTION 3.NEW SANITARY SEWER PIPE PER CITY STD DETAIL 405 1 8 12 *SS NO. SPECIFIC TO THIS SHEET DETAIL 1 SCALE: 1"=5' KING COUNTY INTERCEPTOR TIE-IN CLOCK TOWER CANOPY 40PROTECT CLOCK TOWER IN PLACE OR REMOVE AND REPLACE. IF FOUNDATION IS DAMAGED, PROVIDE STAMPED AND SIGNED FOUNDATION DESIGN DRAWINGS KING COUNTY MANHOLE R01-17 CONNECTION CLOCK TOWER FOOTING 1 - 2 SS-41 PREVIOUSLY ABANDONED SHORING MAY BE ENCOUNTERED IN THE VICINITY OF KING COUNTY EASTSIDE INTERCEPTOR, REMOVE AND DISPOSE AS NEEDED TO COMPLETE THE WORK 8 CLOCK TOWER SCALE: NTS CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' GAS WILL BE DEACTIVATED BY PSE PRIOR TO CONSTRUCTION 613 617 700 290 280 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS CONC. MON. IN CASE REESTABLISHED PER DNR PERMIT 7417- 18"T x 6"W •••••••••••••••••••••••••••••••••••••••••••••3232STOP12"C900 SD12"C900 SDSTA E2+63, 0' RT SSMH #23 1-48" DIA MH STA E1+78, 0' LT SSMH #39 1-48" DIA MH E 2 + 0 0 E3+00 E4+00 E5+008" SDR 35 SS 8 " S D R 3 5 S S 24" C900 SS10 15 20 25 30 35 40 10 15 20 25 30 35 40 E1+00 E1+20 E1+40 E1+60 E1+80 E2+00 E2+20 E2+40 E2+60 E2+80 E3+00 E3+20 E3+40 E3+60 E3+80 E4+00 E4+20 E4+40 E4+60 E4+80 E5+00 25.10 25.26 248 LF 8" PVC SS @ SLP=0.4% 250EXIST SSEXIST SDEXIST 12 & 18"SDEXIST 12"SDEXIST TEXIST UGPEXIST 12"SDEXIST 8"WEXIST WEXIST TEXIST UGPEXIST UGP0.4% 87 LF 8" SDR 35 SS @ SLP=0.5%248 LF 8" SDR 35 SS @ SLP=0.4% SSMH #39 IE(IN)6"(NW)=25.53 IE(OUT)8"(NE)=25.36 STA E1+78, 0' LT RIM=32.55 SSMH #23 IE(IN)8"(SW)=24.97 IE(IN)6"(S)=25.06 IE(OUT)8"(N)=24.96 STA E2+65, 0' LT RIM=31.15 18-2251 SS-12 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET PARKING LOT EASEMENT SEWER PLAN & PROFILE STA E1+00 TO STA E5+00 JJM BAW TTT 61NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-12 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ PIPE CLS 3RD STMATCHLINE STA F5+00SEE SHEET SS-13CONTINUATION SEE SHEET SS-6 SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 230 RAINIER AVE S E3+38 N: E: 250 RAINIER AVE S E1+77 SSMH#39 N: E: 112 S 3RD ST E2+63 SSMH#23 N: E: UNKNOWN E2+12 N: E: 1 2 3 4 152 134 1.PROPOSED SEWER MAY HAVE CONFLICT OR SEQUENCE CONSTRAINT WITH EXISTING UTILITY TO BE ABANDONED, CONTRACTOR SHALL TAKE APPROPRIATE MEASURES TO MAINTAIN THE FUNCTIONALITY OF THE EXISTING UTILITY UNTIL SUCH TIME AS IT CAN BE ABANDONED 2.CONDUCT SITE SPECIFIC UTILITY POTHOLING IN ADVANCE OF CONSTRUCTION TO CONFIRM LOCATION AND ELEVATION OF EXIST UTILITY 3.NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, AND 106 4.NEW SANITARY SEWER PIPE PER CITY STD DETAIL 405 5.INSTALL SIDE SEWER PER CITY STD DETAIL 406.1, 406.2, AND/OR 407 AND CO IF SHOWN 6.CONNECT EXIST PIPE TO NEW PIPE W/ CPLG, SEE DETAIL 2, SHT SS-42 7.COORDINATE WORK IN PARKING LOTS WITH PROPERTY OWNERS. MAINTAIN ACCESS AND MINIMIZE CONSTRUCTION IMPACT TO THE GREATEST EXTENT FEASIBLE. ANY DAMAGE BEYOND EXTENTS SHOWN SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE 8.COORDINATE LIGHT REMOVAL AND REPLACEMENT WITH PROPERTY OWNER 9.EXISTING SSMH IE=23.9. PLACE AND COMPACT ADDITIONAL FOUNDATION MATERIAL AS REQ'D TO SET NEW SSMH AT IE SHOWN 2 10 12 13 *SS NO. SPECIFIC TO THIS SHEET 12 TYP 10 BURIED DEBRIS AND CONTAMINATED SOILS PREVIOUSLY ENCOUNTERED IN THIS AREA, REMOVE AND DISPOSE IN ACCORDANCE WITH SPECS 15 32 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 250 112 300 153 33 3 3 10 3 3 131 10 10 REPLACE FENCE IN KIND COORDINATE WITH CITY DURING CONSTRUCTION TO DETERMINE IF SIDE SEWER IS ACTIVE PRIOR TO RECONNECTING 20 20 19 21 19 20 21 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS INACTIVE SS CUT AND CAPPED CONNECTED 52' S OF SSMH #23, 3'8" DEEP FOUND ECOLOGY BLOCK AT WATER MAIN 4-FT DEEP •••••••••••••••••••••••••••••32 32 31 32 NO PARKINGPARKING FIRE LANEFIRE LANE NO PARKING FIRE LANE NO PARKINGNO PARKING FIRE LANENO PARKING FIRE LANESTOP 3 2 32 CRPL#3 66" STL CRPL#2 51.5" STL CRPL#1 66" STLCRPL#1 66" STL CRPL#2 51.5" STL CRPL#3 66" STL ••••••••••••••••••••••••••••••••••••••••••••••••••••••••STA E5+94, 1' LT SSMH #24 1-48" DIA MH STA E5+13, 0' RT SSMH #6476 1-48" DIA MH E5+00E6+00 E7+00 E8+00 8" C900 SS8" C900 SS EXIST SSMH 6476 IE(IN)8"(S)=23.93 IE(IN)8"(W)=25.91 IE(OUT)12"(N)=23.93 STA E5+13, 0' LT RIM=31.73 10 15 20 25 30 35 40 10 15 20 25 30 35 40 E5+00 E5+20 E5+40 E5+60 E5+80 E6+00 E6+20 E6+40 E6+60 E6+80 E7+00 E7+20 E7+40 E7+60 E7+80 E8+00 0.1% 25.70 0.4%EXIST 42" SDEXIST WEXIST UGPEXIST UGPEXIST UGP81 LF 12" CIPP SS @ SLP=0.4%237 LF 12" CIPP SS @ SLP=0.1% 31.56 SSMH #24 IE(IN)12"(S)=23.57 IE(OUT)12"(E)=23.61 IE(OUT)8"(NW)=24.60 STA E5+94, 1' LT RIM=31.45 23.70 23.70 24.80 18-2251 SS-13 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET PARKING LOT EASEMENT SEWER PLAN & PROFILE STA E5+00 TO STA E8+00 JJM BAW TTT 62NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-13 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 S 2ND ST 234 LF 12" CIPP SS 78 LF 12" CIPP SS6.NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, AND 106 6.GROUT NEW PIPE INTO EXIST SSMH W/ SANDED ADAPTER AND RE-CHANNEL SSMH, SEE DETAIL 1, SHT SS-42 7.CONNECT EXIST PIPE TO NEW PIPE W/ CPLG, SEE DETAIL 2, SHT SS-42 8.DO NOT REINSTATE INACTIVE SERVICE LATERAL MATCHLINE STA E8+00SEE SHEET SS-1410 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE MATCHLINE STA E8+00SEE SHEET SS-14EXIST 12" CLAY EXIST 12" CLAY 17 17 17 17 17 17 EXIST GR @ ROW CL 15 SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 101 S 2ND ST SSMH #6476 N: E: *SS NO. SPECIFIC TO THIS SHEET 10 TYP 10 15 17 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 203 MATCHLINE STA E5+00 SEE SHEET SS-12 MATCHLINE STA E5+00SEE SHEET SS-1214 14 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS •••••••••••••••••••••••••••••••••••••••••••••••••3 3 32 3232 32 31 32 31NO PARKING FIRE LANENO PARKINGNO PARKINGNO PARKING FIRE LANE3 2 3231 32 32CRPL#3 66" STL CRPL # 1 6 6 " S T L CRPL # 2 5 1 . 5 " S T L •••••••••••••••••••••••••••••••••••••12"PP SD 8" D I S D TS TS TSSTA E11+41, 0' RT SSMH #0066 IE=21.6 S IE=21.6 SE (ABAND) IE=22.7 NW STA E9+95, 1' RT SSMH #26 1-48" DIA MH STA E8+30, 1' LT SSMH #25 1-48" DIA MH E11 + 5 1 E8+00 E9+00 E10+ 0 0 E11+ 0 0 SSMH #0066 IE(IN)12"(W)=22.72 IE(OUT)8"(S)=22.05 STA F2+33, 8' RT= STA E11+41, 0' LT RIM=31.71 10 15 20 25 30 35 40 10 15 20 25 30 35 40 E8+00 E8+20 E8+40 E8+60 E8+80 E9+00 E9+20 E9+40 E9+60 E9+80 E10+00 E10+20 E10+40 E10+60 E10+80 E11+00 E11+20 E11+40 E11+60 23.40 31.68EXIST SDEXIST SDEXIST UGP & GEXIST SDEXIST TEXIST WEXIST UGP165 LF 12" CIPP SS @ SLP=0.2%146 LF 12" CIPP SS @ SLP=0.2% SSMH #25 IE(IN)12"(W)=23.46 IE(IN)6"(S)=24.07 IE(OUT)12"(E)=23.36 STA E8+30, 1' LT RIM=31.61 SSMH #26 IE(IN)12"(W)=23.00 IE(OUT)12"(E)=23.00 STA E9+95, 1' RT RIM=32.05 21.60 18-2251 SS-14 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET PARKING LOT EASEMENT SEWER PLAN & PROFILE STA E8+00 TO STA E11+60 JJM BAW TTT 63NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-14 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 S 2ND S T 165 LF 12" C I P P S S 1.NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, AND 106 2.GROUT NEW PIPE INTO EXIST SSMH W/SANDED ADAPTER AND RE-CHANNEL SSMH, SEE DETAIL 1, SHT SS-42 3.CONNECT EXIST PIPE TO NEW PIPE W/ CPLG, SEE DETAIL 2, SHT SS-42 4.DO NOT REINSTATE INACTIVE SERVICE LATERAL 10 15 MATCHLINE STA E8+00SEE SHEET SS-13SHATTUCK AVE SFOR CONTINUATIONSEE SHEET SS-3FOR CONTINUATION SEE SHEET SS-15SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 203 S 2ND ST E3+20 SSMH 25 N:178534.78 E:1298901.831 14 1 144 L F 1 2 " C I P P S S 15 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILEMATCHLINE STA E2+80SEE SHEET SS-13EXISTING PIPE STUB AT MH IS OFFSET, SEE CCTV FOOTAGE EXCAVATE, RE-ALIGN, AND BACKFILL EXISTING PIPE STUB AND REPLACE CPLG W/ ROMAC 501 BEFORE CIPP IS INSTALLED TO PREVENT WRINKLING EXIST 12" CLAY EXIST 12" CLAY EXIST GR @ ROW CL 17 10 10 15 SSMH #6 SEE SHT SS-3 SSMH #26 SEE SHT SS-15 SPU ROW 14 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 211 10 10 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••323333323232 32 32 32 31 3 2 CRPL#2 51.5" STLCRPL#1 66" STLCRPL#3 66" STLCRPL#1 66" STLCRPL#2 51.5" STL•••••••••••••••••••••••FO DUCTFO DUCT18" PP SD 18" PP SD 18" PP SD12"PP SD12"PP SD12"PP SD15"PP SD8" DI SD12"DI W12"DI W12"DI W12"DI WTSTS TSTS TSTS STA F4+43, 8' RT SSMH #28 1-48" DIA MH STA F1+60, 1' LT SSMH #27 1-48" DIA MH E11+51E11+00F1+00 F2+00 F3+00 F4+00 F5+00 8" SDR 35 SS8" SDR 35 SS2"PVC CONDUIT10 15 20 25 30 35 40 10 15 20 25 30 35 40 F0+80 F1+00 F1+20 F1+40 F1+60 F1+80 F2+00 F2+20 F2+40 F2+60 F2+80 F3+00 F3+20 F3+40 F3+60 F3+80 F4+00 F4+20 F4+40 F4+60 F4+80 F5+00 F5+20 F5+40 F5+60 20.76 STA F4+43, 8' RT21.00 STA F1+60, 1' LT 0.4%EXIST TEXIST WEXIST TEXIST COMEXIST & PROP SDEXIST UGPEXIST UGPEXIST SD(TO BE ABAN)EXIST UGPEXIST TEXIST W21.42 20.80 32.06 0.7%PROP 8"SDIE=29.3PROP SDPROP 12"SDIE=27.1PROP WSSMH #5 IE(IN)8"(W)=21.88 IE(OUT)15"(E)=21.23 STA F0+88, 1' LT RIM=32.31 34 LF 8" SDR 35 SS @ SLP=1.0% SSMH #0066 IE(IN)12"(W)=22.72 IE(OUT)8"(S)=22.05 STA F2+33, 8' RT RIM=31.71 210 LF 8" SDR 35 SS @ SLP=0.7% 213 LF 8" SDR 35 SS @ SLP=0.6% 20.87 20.54 32.09 EXISTING MANHOLE KEPT IN PLACE IE(IN)6"(E)=21.94 21.10 0.4% SSMH #27 IE(OUT)8"(N)=21.99 STA F1+62, 3' LT RIM=31.92 SSMH #28 IE(IN)8"(N)=20.59 IE(OUT)8"(S)=20.57 STA F4+43, 6' RT RIM=31.96 SSMH #6 IE(IN)8"(S)=21.65 IE(OUT)8"(E)=21.29 STA A9+75, 28' RT RIM=32.50 1' LT 21.60 18-2251 SS-15 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET SHATTUCK AVE S SEWER PLAN & PROFILE STA F0+00 TO STA F5+60 JJM BAW TTT 64NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-15 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE SSMH #6, SEE SHT SS-3 EXIST GR @ ROW CLS 2ND STMATCHLINE STA F5+60SEE SHEET SS-16SHATTUCK AVE S MATCHLINE STA F5+60SEE SHEET SS-1612 TYP 10 10 1 2 2 13 3 13 4 13 5 13 6 13 SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 305, 309, 315, 319 & 321 S 2ND ST F1+60 SSMH #27 N:178526.70 E:1299237.56 211 SHATTUCK AVE S F2+58 N:178440.86 E:1299182.65 SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 220 SHATTUCK AVE S F3+65 N: E: 211 SHATTUCK AVE S F4+23 N: E: SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 300 S 3RD ST F5+05 N:178200.09 E:1299216.61 212 S 3RD ST F5+34 N:178164.48 E:1299177.23 1 2 3 4 5 6 1.CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 2.PROPOSED SEWER MAY HAVE CONFLICT OR SEQUENCE CONSTRAINT WITH EXISTING UTILITY TO BE ABANDONED, CONTRACTOR SHALL TAKE APPROPRIATE MEASURES TO MAINTAIN THE FUNCTIONALITY OF THE EXISTING UTILITY UNTIL SUCH TIME AS IT CAN BE ABANDONED 6.NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, AND 106 7.NEW SANITARY SEWER PIPE PER CITY STD DETAIL 405 8.INSTALL SIDE SEWER PER CITY STD DETAIL 406.1, 406.2, AND/OR 407 AND CO IF SHOWN 9.GROUT NEW PIPE INTO EXIST SSMH W/ SANDED ADAPTER AND RE-CHANNEL SSMH, SEE DETAIL 1, SHT SS-42 1 2 10 12 13 14 FOR CONTINUATION SEE SHEET SS-2 FOR CONTINUATION SEE SHEET SS-3 *SS NO. SPECIFIC TO THIS SHEET FOR CONTINUATION SEE SHEET SS-14 10 10 131 14 REPLACE SS TO GUTTER 10 SPU ROW5555AT&T CRITICAL FIBER OPTIC PROTECT-IN-PLACE PER 1-07.17 CITY ROWSPU ROWCITY ROW CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20'5453211 220 300 212 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS STORM LATERAL, REROUTED TO SDMH #2 IE: 23.43 IE: 24.32 IE: 23.04 IE: 26.51 IE: 25.20 IE: 25.22 AT&T CRITICAL FIBER OPTIC PROTECT-IN-PLACE PER 1-07.17 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••313131 18" PP SD 18" PP SD24" PP SD12"PP SD12"C900 SD12"DI W F6+00 F7+00 F8+00 8" SDR 35 SS 10 15 20 25 30 35 40 10 15 20 25 30 35 40 F5+60 F5+80 F6+00 F6+20 F6+40 F6+60 F6+80EXIST WEXIST 12"SDIE=26.0EXIST UGP17.87 17.77EXIST SS (TO BE ABAN)EXIST TSSMH #18 IE(IN)8"(N)=19.29 IE(IN)24"(W)=17.70 IE(OUT)24"(E)=17.48 STA C12+73, 6' RT RIM=31.21 STA F6+55, 1' RT 18-2251 SS-16 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET SHATTUCK AVE S SEWER PLAN & PROFILE STA F5+60 TO STA F6+80 JJM BAW TTT 65NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-16 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CLS 3RD STSHATTUCK AVE S MATCHLINE STA F5+60SEE SHEET SS-15MATCHLINE STA F5+60SEE SHEET SS-1512 TYP 1 FOR CONTINUATION SEE SHEET SS-8 FOR CONTINUATION SEE SHEET SS-8 SSMH #18, SEE SHT SS-8 1.CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 2.REPLACE SURVEY MONUMENT PER CITY STD DETAIL H031 AS REQUIRED FOR CONSTRUCTION 3.NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, AND 106 4.NEW SANITARY SEWER PIPE PER CITY STD DETAIL 405 1 8 10 12 10 21" SDR 35 SS24" C900 SS8 8" SDR 35 SS CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 301 207 212 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS CONC. MON. IN CASE REESTABLISHED PER DNR PERMIT 7373-18"T x 6"W ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••333433 3333 33 33 CRPL #2 51.5" STLCRPL#3 66" STLCRPL#1 66" STL••••••••••••••••••••••••••••••••••••••FO DUCTFO DUCT12" PP SD 8"DI SD8 " D I S D12"DI SD8"DI SD 8"DI SD12"DI W 12"DI W12"DIWTSTSTSTS TS TS G0+00 G1+00 G2+00 G3+008" C900 SS8" C900 SS8" SDR 35 SS10 15 20 25 30 35 40 10 15 20 25 30 35 40 G0+00 G0+20 G0+40 G0+60 G0+80 G1+00 G1+20 G1+40 G1+60 G1+80 G2+00 G2+20 G2+40 G2+60 G2+80 G3+00 G3+20 0.4%EXIST 66"W (SPU)EXIST 12"SDIE=28.4EXIST UGP & TEXIST WS(TO BE REMOVED)EXIST 51.5"W (SPU)EXIST 12"SDIE=28.719.21 19.21 19.11 33.23 EXIST WSEXIST & PROP WEXIST 6"SDIE=29.8PROP FHPROP WSPROP 12"SDIE=30.4PROP 8"SDIE=30.8EXIST 2"GEXIST 2"G366 LF 8" C900 SS @ SLP=0.5%SSMH #7 IE(IN)8"(W)=19.50 IE(IN)8"(E)=19.45 IE(OUT)8"(S)=19.45 STA A12+87, 28' RT RIM=33.07 3'-0"18-2251 SS-19 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET WHITWORTH AVE S SEWER PLAN & PROFILE STA G0+00 TO STA G3+20 JJM BAW TTT 66NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-19 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CL WHITWORTH AVE S MATCHLINE STA G3+20SEE SHEET SS-20MATCHLINE STA G3+20SEE SHEET SS-2012 TYP 1 S 2ND STSIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 215 WHITWORTH AVE S G2+65 N: E: 220 WHITWORTH AVE S G3+15 N: E: 1 2 13 1 13 2 SSMH #7, SEE SHT SS-3 1.CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 2.NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, AND 106 3.NEW SANITARY SEWER PIPE PER CITY STD DETAIL 405 4.INSTALL SIDE SEWER PER CITY STD DETAIL 406.1, 406.2, AND/OR 407 AND CO IF SHOWN 1 10 12 13 FOR CONTINUATION SEE SHEET SS-3 FOR CONTINUATION SEE SHEET SS-3 *SS NO. SPECIFIC TO THIS SHEET 10 5' MIN PROTECT SPU WATER IN PLACE PER 1-07.17, DO NOT ALLOW EXIST PEA GRAVEL BACKFILL TO UNRAVEL, BACKFILL PIPE BEDDING PER SPU STD PLAN 350 REPLACE SS TO GUTTER SPU ROWSPU ROW14CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20'5960319 215 220 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS IE=28.78 IE=29.06 SEE SS-20 FOR SIDE SEWER CONNECTION APPROX. EXTENT OF CASING ••••••••••••••••••••••••••33333333 33••••••18" PP SD18" PP SD12" PP SD 12" PP SD 12"D I S D 12"DI SD12"DI SD12"DI W G4+00 G5+00 G6+00G6+00 24" C900 SS24" C900 SS8" C900 SS STA G3+94, 2' RT SSMH #29 1-60" DIA MH 5 10 15 20 25 30 35 5 10 15 20 25 30 35 G3+20 G3+40 G3+60 G3+80 G4+00 G4+20 G4+40 G4+60 G4+80 G5+00 G5+20 G5+40 G5+60 G5+80 G6+00 0.4% 26.40 17.55 STA G3+95, 0' LT 32.97 EXIST WSEXIST GEXIST WSEXIST UGPEXIST WEXIST TEXIST UGPEXIST UGPEXIST & PROP SD15.56 16.90 15.46 33.11EXIST GPROP 12"SDIE=26.7PROP 18"SDIE=23.0164 LF 8" C900 SS @ SLP=0.5% SSMH #29 IE(IN)8"(N)=17.71 IE(IN)8"(E)=26.18 IE(OUT)8"(S)=17.57 STA G3+94, 2' RT RIM=32.74 SSMH #19 IE(IN)24"(W)=15.94 IE(IN)8"(N)=16.79 IE(OUT)24"(E)=15.64 STA C15+87, 6' RT= STA G5+58, 5' RT RIM=32.94 STA G5+58, 0' LT17.65 18-2251 SS-20 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET WHITWORTH AVE S SEWER PLAN & PROFILE STA G3+20 TO STA G6+00 JJM BAW TTT 67NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-20 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CL WHITWORTH AVE S MATCHLINE STA G3+20SEE SHEET SS-19MATCHLINE STA G3+20SEE SHEET SS-19S 3RD ST1 SSMH #19, SEE SHT SS-9 SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 316 3RD ST G3+75 N: E: 400 S 3RD ST G4+52 N:178140.56 E:1299526.46 220 S 3RD ST G4+40 N:178254.92 E:1299530.19 1 2 3 113 FOR CONTINUATION SEE SHEET SS-9 FOR CONTINUATION SEE SHEET SS-9 11 1.CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 2.NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401 AND 106 3.NEW DROP SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, 402.1, 402.2, AND 106 4.NEW SANITARY SEWER PIPE PER CITY STD DETAIL 405 5.INSTALL SIDE SEWER PER CITY STD DETAIL 406.1, 406.2 AND/OR 407 AND CO IF SHOWN 6.CONNECT EXIST PIPE TO NEW PIPE W/ CPLG, SEE DETAIL 2, SHT SS-42 1 10 11 12 13 15 11 2 *SS NO. SPECIFIC TO THIS SHEET 12 TYP 10 15 13 38REPLACE SS TO GUTTER CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20'15400 401 325 321 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS IE=26.09 SEE SS-19 FOR CONNECTION 3 •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••343 5 35343433 33 3333 CRPL #3 66" STL••••••••••••••••••••••••••••8"C900 SD 8"DI SD8"DI SD 12"C900 SDH0+00 H1+00 H2+008" C900 SS8" SDR 35 SS 8" C900 SS8" SDR 35 SS2"PVC CONDUITSTA H2+21, 13' LT SSMH #30 1-48" DIA MH 15 20 25 30 35 40 45 15 20 25 30 35 40 45 H0+00 H0+20 H0+40 H0+60 H0+80 H1+00 H1+20 H1+40 H1+60 H1+80 H2+00 H2+20 H2+40 0.4%EXIST WEXIST UGPEXIST TEXIST UGPEXIST & PROP SDEXIST WEXIST TEXIST TEXIST UGP24.53 24.53 24.43 192 LF 8" SDR 35 SS @ SLP=0.8% SSMH #30 IE(OUT)8"(N)=25.29 STA H2+21, 13' LT RIM=33.22 SSMH #8 IE(IN)8"(E)=23.83 IE(IN)8"(S)=23.81 IE(OUT)8"(W)=23.79 STA A16+15, 29' RT= STA H0+29, 13' LT RIM=33.77 15' LT •••••••••••••••••••••••••••••••••••••••••••••••••••3434 33 3412" C900 SD 18" PP SD12" PP SD12" PP SD12" PP SD 12"D I S D12"DI SD12"DI SDH4+00 H5+00 8" SDR 35 SS 24" C900 SS24" C900 SSSTA H3+99, 12' RT SSMH #31 1-48" DIA MH 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 H3+80 H4+00 H4+20 H4+40 H4+60 H4+80 H5+00 H5+20 H5+40 H5+60 H5+80 33.78PROP & EXIST SDEXIST UGPEXIST W1.3% 15.16 15.06 STA H5+62, 11' RT 33.84PROP 18"SDIE=26.1PROP 12"SDIE=26.8164 LF 8" SDR 35 SS @ SLP=1.2 % SSMH #20 IE(IN)24"(W)=15.34 IE(IN)8"(N)=23.58 IE(OUT)24"(E)=15.27 STA C18+99, 8' RT RIM=33.66 SSMH #31 IE(OUT)8"(S)=25.63 STA H3+99, 12' RT RIM=33.38 18-2251 SS-21 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET MORRIS AVE S SEWER PLAN & PROFILE STA H0+00 TO STA H5+80 JJM BAW TTT 68NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-21 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CL MORRIS AVE S S 2ND STMORRIS AVE S S 3RD STEXIST GR @ ROW CL SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE TYP 1 SSMH #8, SEE SHT SS-4 SSMH #20, SEE SHT SS-10 12 TYP 10 10 SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 507 S 2ND ST H0+80 N:178500.72 E:1299869.05 419 S 2ND ST H0+84 N:178516.86 E:1299820.85 SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 211 MORRIS AVE S H1+56 N:178435.90 E:1299818.74 280 MORRIS AVE S, 504 S 3RD ST UNK N:178182.83 E:1299852.26 1 2 3 4 2 13 3 13 FOR CONTINUATION SEE SHEET SS-9 FOR CONTINUATION SEE SHEET SS-10 FOR CONTINUATION SEE SHEET SS-4 FOR CONTINUATION SEE SHEET SS-4 1.CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 2.NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, AND 106 3.NEW DROP SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, 402.2, AND 106 4.NEW SANITARY SEWER PIPE PER CITY STD DETAIL 405 5.INSTALL SIDE SEWER PER CITY STD DETAIL 406.1, 406.2 AND/OR 407 AND CO IF SHOWN 1 10 11 12 13 1010 *SS NO. SPECIFIC TO THIS SHEET 1110 134 DISTANCE BETWEEN SIDE SEWER AND EXIST MAIN IS UNKNOWN, CONTRACTOR TO LOCATE, REMOVE BEND TO MAKE STRAIGHT SS CONNECTION TO NEW SEWER 1 13 TYPTYP CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 507 225 280 422211 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 225 LOGAN AVE S H1+51 N:178429.00 E:1299854.42 225 LOGAN AVE S H1+90 N:178400.68 E:1299869.49 211 MORRIS AVE S H2+12 N:178377.97 E:1299817.61 211 MORRIS AVE S H2+16 N:1783745.33 E:199819.39 422 S 3RD ST H4+04 N:178186.78 E:1299793.94 5 6 7 8 9 IE=31.23 IE=31.56 8 13713 29'-1" 513 613 9 13 EXISTING 6" SS25.7 DEPTH=5' IE=29.32 DEPTH=5' IE=31.18 REPLACE SS TO GUTTER 222 •••••••••••••••••••••••••••••••••••38 393939CRPL #3 66" STLSTA J0+18, 1' LT SSMH #32 1-60" DIA MH J0+00 J1+0012" C900 SS 2"PVC CONDUIT15 20 25 30 35 40 45 15 20 25 30 35 40 45 J0+00 J0+20 J0+40 J0+60 J0+80 J1+00 27.94 32.10 EXIST TEXIST WEXIST T DUCTEXIST T DUCTEXIST TEXIST UGPEXIST UGPEXIST 6"SDEXIST 66" W (SPU)0.8% 44 LF 12" PVC SS @ SLP=0.3% SSMH #32 IE(IN)12"(S)=28.04 IE(IN)8"(N)=31.94 IE(OUT)12"(W)=27.93 STA J0+17, 2' LT RIM=38.41 SSMH #12 IE(IN)8"(W)=28.25 IE(IN)12"(E)=31.90 IE(IN)8"(S)=31.90 IE(OUT)12"(N)=28.15 STA A23+19, 7' LT= STA J0+61, 7' LT RIM=38.67 STA J0+63, 6' LT 27.84 28.41 32.00 32.00 28.31 18-2251 SS-22 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET BURNETT AVE S SEWER PLAN & PROFILE STA J0+00 TO STA J1+00 JJM BAW TTT 69NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-22 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CL BURNETT AVE SS 2ND STSSMH #12, SEE SHT SS-5 1 12 TYP 11 FOR CONTINUATION SEE SHEET SS-5 1.CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 2.CONDUCT SITE SPECIFIC UTILITY POTHOLING IN ADVANCE OF CONSTRUCTION TO CONFIRM LOCATION AND ELEVATION OF EXIST UTILITY 3.REPLACE SURVEY MONUMENT PER CITY STD DETAIL H031 AS REQUIRED FOR CONSTRUCTION 8.NEW DROP SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, 402.2, AND 106 9.NEW SANITARY SEWER PIPE PER CITY STD DETAIL 405 10.CONNECT EXIST PIPE TO NEW PIPE W/ CPLG, SEE DETAIL 2, SHT SS-42 1 3 8 12 15 11 11 KING COUNTY MANHOLE R01-20 TIE-IN, SEE DET SHT SS-40 8 15 15 3 11 39PREVIOUSLY ABANDONED SHORING MAY BE ENCOUNTERED IN THE VICINITY OF THE KING COUNTY EASTSIDE INTERCEPTOR, REMOVE AND DISPOSE AS NEEDED TO COMPLETE THE WORK FO INSTALLED BY HDD, PROTECT IN PLACE 3 8"DR 17 HDPE SS BEND TO CONNECT NEW MH TO EXIST PIPE, MIN R-40' CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 3 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS 23 LF INSTALLED WATER LINE ALIGNMENT AS FOUND IN FIELD EXIST W (8'-4" DEEP)CONC. MON. IN CASE REESTABLISHED PER DNR PERMIT 7373-18"T x 6"W ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••444444 45 4545 464544 4444454 646 CRPL#3 66" STLCPPL#3 66" STLCPPL#3 66" STLCPPL#3 66" STL ••••••••••••••••••••••••••••••••TSTSTSSTA K0+18, 6' LT SSMH #1893 IE 37.3 SE-W @ CL K4+20 K0+00 K1+00 K2+00 K3+00 K4+00 297 LF 12" CIPP SS 12" C900 SS8" SDR 35 SS12" CIPP SSC900C900 STA K3+21, 5' LT SSMH #33 1-48" DIA MH STA K3+95, 5' LT SSMH #34 1-48" DIA MH 25 30 35 40 45 50 55 25 30 35 40 45 50 55 K0+00 K0+20 K0+40 K0+60 K0+80 K1+00 K1+20 K1+40 K1+60 K1+80 K2+00 K2+20 K2+40 K2+60 K2+80 K3+00 K3+20 K3+40 K3+60 K3+80 K4+00 K4+20 76EXIST WEXIST WSEXIST WSEXIST WSEXIST WSEXIST FHEXIST FHEXIST SDEXIST GEXIST UGP, T & COMEXIST WSEXIST UGPEXIST G297 LF OF 12" CURED-IN-PLACE PIPEEXIST UGPEXIST TPROP WEXIST WEXIST T39.01 38.60 EXIST 12" CLAY 38.18 38.80 38.52 38.08 STA K3+20, 4' LT37.30 37.30 37.30 74 LF 12" C900 SS @ SLP=0.8% 302 0.6% EXIST SSMH 1893 IE(IN)12"(E)=36.62 IE(IN)8"(S)=36.14 IE(OUT)12"(W)=36.62 STA K0+18, 6' LT RIM=44.65 SSHM #33 IE(IN)12"(E)=38.48 IE(IN)12"(S)=38.38 IE(IN)8"(N)=38.84 IE(OUT)12"(W)=38.35 STA K3+21, 5' LT RIM=46.14 SSMH #34 IE(IN)6"(E)=39.36 IE(OUT)12"(W)=39.10 STA K3+95, 5' LT RIM=45.20 18-2251 SS-24 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 2ND ST SEWER PLAN & PROFILE STA K0+00 TO STA K4+20 JJM BAW TTT 70NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-24 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CL S 2ND ST MILL AVE S15 1 FOR CONTINUATION SEE SHEET SS-25 1.CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 2.REPLACE SURVEY MONUMENT PER CITY STD DETAIL H031 AS REQUIRED FOR CONSTRUCTION 3.NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, AND 106 4.NEW SANITARY SEWER PIPE PER CITY STD DETAIL 405 5.CONNECT EXIST PIPE TO NEW PIPE W/ CPLG, SEE DETAIL 2, SHT SS-42 6.DO NOT REINSTATE INACTIVE SERVICE LATERAL 7.REINSTATE ALL ACTIVE SERVICE LATERAL CONNECTIONS 1 8 10 12 15 10 MAIN AVE S12 TYP 10 15 SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 1000 BRONSON WAY K0+99 N: E: 1010 S 2ND ST K1+31 N: E: 211 MILL AVE S K2+49 N: E: SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 1017 & 1023 BRONSON WAY & 123 MILL AVE S K2+86 N: E: 1 2 3 4 *SS NO. SPECIFIC TO THIS SHEET 1 2 4 3 10 8 SSMH #34, SEE SHT SS-25 10 18 18 18 18 17 18 17 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 1000 1010 301 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS CONC. MON. IN CASE REESTABLISHED PER DNR PERMIT 7373-18"T x 6"W STA K30+20, 9' LT 1-8" x 6" TEE ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••46 4544 45 4544 4 4 45 46 4 343 CRPL#3 66" STL CPPL#3 66" STL12"DI W TS TS TS STA L3+46, 5' RT SSMH #35 1-48" DIA MH STA L3+91, 4' RT SSMH #33 1-48" DIA MH L0+00L1+00 L2+00 L3+00 L4+0012" C900 SS8" SDR 35 SS12" CIPP SSC 9 0 0C900 25 30 35 40 45 50 55 25 30 35 40 45 50 55 L0+00 L0+20 L0+40 L0+60 L0+80 L1+00 L1+20 L1+40 L1+60 L1+80 L2+00 L2+20 L2+40 L2+60 L2+80 L3+00 L3+20 L3+40 L3+60 L3+80 L4+00 L4+20 L4+40 L4+60 L4+80PROP 12" WEXIST UGPEXIST TEXIST TEXIST & PROP SDEXIST COMEXIST WEXIST 12" CLAY 38.18 38.80 38.52 38.08 IE(IN)6"(E)=39.17 STA L3+46, 5' RT 45.87 0.8%EXIST W(PREV ABAN)EXIST UGP & FOEXIST G46 LF 8" SDR 35 SS @ SLP=0.3% SSMH #35 IE(OUT)8"(S)=38.99 STA L3+44, 6' RT RIM=45.69 SSHM #33 IE(IN)12"(E)=38.48 IE(IN)12"(S)=38.38 IE(IN)8"(N)=38.84 IE(OUT)12"(W)=38.35 STA K3+21, 5' LT= STA L3+91, 4' RT RIM=46.14 18-2251 SS-25 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET MILL AVE S SEWER PLAN & PROFILE STA L0+00 TO STA L4+80 JJM BAW TTT 71NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-25 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 MILL AVE S S 2ND STFOR CONTINUATION SEE SHEET SS-24 MATCHLINE STA L4+80SEE SHEET SS-26SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE MATCHLINE STA L4+80SEE SHEET SS-261.CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 2.REPLACE SURVEY MONUMENT PER CITY STD DETAIL H031 AS REQUIRED FOR CONSTRUCTION 3.NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, AND 106 4.NEW SANITARY SEWER PIPE PER CITY STD DETAIL 405 5.INSTALL SIDE SEWER PER CITY STD DETAIL 406.1, 406.2, AND/OR 407 AND CO IF SHOWN 6.CONNECT EXIST PIPE TO NEW PIPE W/ CPLG, SEE DETAIL 2, SHT SS-42 7.DO NOT REINSTATE INACTIVE SERVICE LATERAL 1 8 10 12 13 15 CONTRACTOR TO DETERMINE WHICH SS IS ACTIVE, AND RECONNECT WITH CO, ABANDON OLD SS IN ACCORDANCE W/ SPECS 15 1 13 SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 100 MILL AVE S L3+46 SSMH #35 N: E:1 *SS NO. SPECIFIC TO THIS SHEET 12 10 10 1 8" SDR 35 SS 12" CIPP SS 10 10 8 17 17 17 EXIST GR @ ROW CL FOR CONTINUATION SEE SHEET SS-24 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 1023 100 FOUND ABANDONED 6" WATER LINE, 4' DEEP CONC. MON. IN CASE REESTABISHED PER DNR PERMIT 7373-18"T x 6"W RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••4 7 4 7 5 3 5 2 5 1 50 4 9 48 4 74747 46 46 46 46 46 45 CRPL#3 66" STLCRPL#3 66" STL CRPL#3 66" STL CRPL#3 66" STL 12" PP SD 12"PP SD 8"C900 SD8"C900 SD8"DI SD 12"DI W 12"DI W 12"DI W STA L8+13, 4' RT SSMH #5613 IE=40.50 SW, N L5+00 L6+00 L7+00 L8+00 L9+00L9+00 134 LF 12" CIPP SS284 LF 12" CIPP SS STA L6+75, 4' RT SSMH #36 1-48" DIA MH EXIST MH 5613 IE(OUT)12"(N)=40.93 STA L8+13, 4' RT RIM=46.71 25 30 35 40 45 50 55 25 30 35 40 45 50 55 L4+80 L5+00 L5+20 L5+40 L5+60 L5+80 L6+00 L6+20 L6+40 L6+60 L6+80 L7+00 L7+20 L7+40 L7+60 L7+80 L8+00 L8+20 L8+40 L8+60 L8+80 L9+00 134 LF 12" CURED-IN-PLACE PIPE EXIST UGPEXIST FHEXIST TEXIST WSEXIST WSEXIST SD40.50 284 LF 12" CURED-IN-PLACE PIPE 138 SSMH #36 IE(IN)12"(S)=40.10 IE(OUT)12"(N)=40.13 STA L6+75, 4' RT RIM=46.20 18-2251 SS-26 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET MILL AVE S SEWER PLAN & PROFILE STA L4+80 TO STA L9+00 JJM BAW TTT 72NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-26 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 MILL AVE S HOUSER WAY SMATCHLINE STA L4+80SEE SHEET SS-25MATCHLINE STA L4+80SEE SHEET SS-251.CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 2.NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, AND 106 3.GROUT NEW PIPE INTO EXIST SSMH AND RE-GROUT THE SSMH CHANNEL 4.CONNECT EXIST PIPE TO NEW PIPE W/ CPLG, SEE DETAIL 2, SHT SS-42 5.DO NOT REINSTATE INACTIVE SERVICE LATERAL 12.REINSTATE ALL ACTIVE LATERAL CONNECTIONS 1 10 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE 1 10 15 14 14 15 17 17 17 17 17 17 17 EXIST 12" CLAY 1 17 1718 EXIST 12" CLAY EXIST GR @ ROW CL SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 211 MILL AVE S L5+33 N: E:1 *SS NO. SPECIFIC TO THIS SHEET 18 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 211 211 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••363 6 35 3534 3534333233 32 33343536 37 3 8 3935 36 37 38 39 40 41 40 39 38 37 36 35 CRPL#3 66" STLCRPL#1 66" STLCRPL#2 51.5" STLCRPL#3 66" STLCRPL#1 66" STLCRPL#2 51.5" STL•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••12"DI WSTA N4+01, 0' SSMH #3 SEE SS-1 STA N0+08, 0' RT SSMH #6645 RIM 37.67 IE 30.8 N, S @ CL 8" CONC N0+00 N1+00 N2+00 N3+00 N4+00 8" SDR 35 SS8" C900 SS8" SDR 35 SSSTA N3+57, 0' LT SSMH #37 1-60" DIA MH 10 15 20 25 30 35 40 10 15 20 25 30 35 40 N0+00 N0+20 N0+40 N0+60 N0+80 N1+00 N1+20 N1+40 N1+60 N1+80 N2+00 N2+20 N2+40 N2+60 N2+80 N3+00 N3+20 N3+40 N3+60 N3+80 N4+00 N4+20 24.57 24.57 24.47 1.0%EXIST T & UGPEXIST TEXIST T & UGPEXIST UGPEXIST SDEXIST WSEXIST GINSTALL 398 LF 8" CURED- I N - P L A C E P I P E EXIST 8" CLAY PROP W46 LF 8" SDR 35 SS @ SLP=0.1% SSMH 6645 IE(OUT)8"(S)=30.80 STA N0+08, 0' RT RIM=37.67 SSMH #37 IE(IN)8"(N)=27.71 IE(OUT)8"(S)=25.05 STA N3+55, 1' LT RIM=33.66 SSMH #3 IE(IN)8"(W)=25.09 IE(IN)8"(N)=25.00 IE(OUT)8"(E)=24.83 STA A2+36, 16' RT= STA N4+01, 0' LT RIM=33.78 33.77 26.92 26.10 44 25.10 18-2251 SS-27 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET SIDE SEWER PLAN & PROFILE STA N0+00 TO STA N4+00 JJM BAW TTT 73NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-27 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE EXIST GR @ ROW CL S 2ND ST2.PROPOSED SEWER MAY HAVE CONFLICT OR SEQUENCE CONSTRAINT WITH EXISTING UTILITY TO BE ABANDONED, CONTRACTOR SHALL TAKE APPROPRIATE MEASURES TO MAINTAIN THE FUNCTIONALITY OF THE EXISTING UTILITY UNTIL SUCH TIME AS IT CAN BE ABANDONED NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, AND 106 3.NEW DROP SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, 402.1, 402.2, AND 106 4.NEW SANITARY SEWER PIPE PER CITY STD DETAIL 405 5.CONNECT EXIST PIPE TO NEW PIPE W/ CPLG, SEE DETAIL 2, SHT SS-42 6.DO NOT REINSTATE INACTIVE SERVICE LATERAL 7.REINSTATE ALL ACTIVE LATERAL CONNECTIONS 10 11 12 15 10 10 12 TYP SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 110 RAINIER AVE S N0+50 N: E: 124 RAINIER AVE S N1+00 N: E: SIDE SEWER TABLE SIDE SEWER NO.*ADDRESS APPROX STATION AT MAIN COORDINATES OF CO OR CPLG 128 RAINIER AVE S N1+45 N: E: 134 RAINIER AVE S N1+72 N: E: 1 2 3 4 398 LF 8" CIPP SS 8" SDR 35 SS FOR CONTINUATION SEE SHEET SS-1 FOR CONTINUATION SEE SHEET SS-1 15 17 18 SSMH 5210 17 17 17 17 17 17 2 18 1 18 3 18 4 18 2317 SSMH LOCATED BEHIND FENCE 11 11 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 2 2 123 140 110 124 126 128 100 134 144 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••34 33 32 32 31 32 35 32 31 33 33 333232•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• ••• • • • • • • • •••••••••••••••••••••••••••••••B0+00 B1+00 B2+00 B3+0 0 B3+2 0 18" C900 SS24" C900 SSSTA B0+89, 29' RT SSMH #2184 IE 26.5 N, S @ CL 8" CLAY 10 15 20 25 30 35 40 45 10 15 20 25 30 35 40 45 B0+00 B0+20 B0+40 B0+60 B0+80 B1+00 B1+20 B1+40 B1+60 B1+80 B2+00 B2+20 B2+40 B2+60 B2+80 B3+00 B3+20 SAN SWR-ALIGN B 167 LF 8" CURED-IN-PLACE PIPE EXIST UGPEXIST 8" CLAY (ABAN) SSMH #13 IE(IN)18"(W)=23.90 IE(IN)8"(N)=25.45 IE(OUT)24"(SE)=23.45 IE(OUT)12"(E)=25.50 STA C2+62, 38' LT= STA B2+42, 57' RT RIM=31.95 SSMH 2184 IE(OUT)8"(S)=26.40 STA B0+89, 29' RT RIM=32.71 26.50 18-2251 SS-28 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET RANIER AVE S SEWER PLAN & PROFILE STA B0+00 TO STA B3+20 JJM BAW TTT 74NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-28 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 1.CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-5 2.NEW SSMH AS SHOWN PER CITY STD DETAIL 400.1, 401, AND 106 3.CONNECT EXIST PIPE TO NEW PIPE W/ CPLG, SEE DETAIL 2, SHT SS-42 4.DO NOT REINSTATE INACTIVE SERVICE LATERALS 1 10 15 17 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE RAINIER AVE S SW SUNSET BLVD1 15 SSMH #13 SEE SHT SS-6 FOR CONTINUATION SEE SHEET SS-6 FOR CONTINUATION SEE SHEET SS-6 167 LF 8" CIPP SS EXIST GR @ ROW CL 10 17 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 307 230 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS 18-2251 SS-40 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET KING COUNTY CONNECTION DETAIL S 2ND ST & BURNETT AVE S JJM BAW TTT 75NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-40 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 CITY OF RENTON AS-BUILT OF EXISTING DROP CONNECTION SCALE: NTS KING COUNTY MANHOLE R01-20 DROP PIPE DEMOLITION AND INSPECTION SCALE: NTS KING COUNTY MANHOLE R01-20 DROP PIPE UPPER PORTION RECONSTRUCTION SCALE: NTS KING COUNTY MANHOLE R01-20 DROP PIPE LOWER PORTION REPLACEMENT (BID ITEM B54) ABANDON EXISTING EXTERIOR DROP PENETRATION W/ BLIND FLANGE RIM=38.39 EXIST IE=31.74 REMOVE UPPER CONNECTION, PROVIDE TESTING AND CCTV INSPECTION OF LOWER PORTION CONTINGENT REMOVAL OF LOWER PORTION, SEE NOTE BELOW FURNISH & INSTALL: 1-2" CPLG, RESTR, PVCxDI 1-12" CROSS, RJ 1-DI SPL IE=27.69' CORE DRILL AND INSTALL KOR-N-SEAL MATCH EXIST IE=8.5'± 6" MIN IF DIRECTED BY ENGINEER FURNISH & INSTALL: 1-12" 90° BEND, RJ 2-DI SPL CEMENT CONCRETE CLASS 3000 6" MIN 6" MAX 6" MIN 2'-0" SAND OR EXPANDABLE FOAM VICTAULIC CPLG & END CAP W/316 SS BOLTS MH FRAME AND COVER PER CITY STD PLAN 401 ADJUSTMENT RING PER CITY STD PLAN 400.1 NOTES: 1.FOLLOWING THE CONTRACTOR'S CCTV INSPECTION OF THE LOWER PORTION OF THE EXISTING EXTERNAL DROP, THE ENGINEER WILL DETERMINE IF THE LOWER PORTION WILL BE RE-USED OR REPLACED. IF REPLACEMENT IS REQUIRED, IT SHALL BE CONSTRUCTED AS SHOWN IN THE LOWER PORTION REPLACEMENT DETAIL ON THIS SHEET ADJUSTMENT AND ASPHALT PATCH PER CITY STD PLAN 106 KING COUNTY WASTEWATER TREATMENT DIVISION SEWER NOTES: 1.KING COUNTY SHALL REVIEW AND COMMENT ON THE CONTRACTORS ACCIDENT PREVENTION PROGRAM (APP) PER WAC 296-800-140/296-155-110 AND SITE SPECIFIC/ PROJECT SPECIFIC HEALTH AND SAFETY PLAN (HASP) PER WAC 296-155/WD 27.00. 2.KING COUNTY MANHOLES ARE PERMIT REQUIRED CONFINED SPACES AND ALL APPLICABLE RULES AND REGULATIONS SHALL BE FOLLOWED PRIOR TO ENTRY. 3.NOTIFY MARK LAMPARD AT KING COUNTY (206-477-5414, MARK.LAMPARD@KINGCOUNTY.GOV) A MINIMUM OF FIVE (5) WORKING DAYS IN ADVANCE OF THE PRE-CONSTRUCTION CONFERENCE. 4.CONTRACTOR SHALL NOTIFY MARK LAMPARD AT KING COUNTY (206-477-5414, MARK.LAMPARD@KINGCOUNTY.GOV) A MINIMUM OF THREE (3) WORKING DAYS IN ADVANCE OF ANY CONSTRUCTION ACTIVITY WITHIN 50-FEET OF THE KING COUNTY EASTSIDE INTERCEPTOR. 5.THE CONTRACTOR SHALL TAKE MEASURES TO PROTECT THE EASTSIDE INTERCEPTOR DURING SHORING ACTIVITY. 6.KING COUNTY SHALL REVIEW THE SHORING PLANS. 7.A KING COUNTY REPRESENTATIVE SHALL BE PRESENT AT ALL TIMES ON-SITE DURING EXCAVATION, CORING, AND INSTALLATION OF THE CONNECTION TO THE KING COUNTY EASTSIDE INTERCEPTOR. 8.NO DEBRIS SHALL BE PERMITTED TO ENTER THE KING COUNTY SEWER SYSTEM DURING CONSTRUCTION OF/OR CONNECTION TO THE KING COUNTY EASTSIDE INTERCEPTOR. 9.NO WORK ON OR CONNECTING TO THE KING COUNTY EASTSIDE INTERCEPTOR SHALL BE BACKFILLED UNTIL THE WORK HAS BEEN INSPECTED AND APPROVED BY A KING COUNTY REPRESENTATIVE. 10.THE CONNECTION TO THE KING COUNTY EASTSIDE INTERCEPTOR SHALL NOT BE PUT INTO SERVICE UNTIL ALL NEWLY INSTALLED PIPE HAS BEEN CLEANED, INSPECTED, TESTED, AND APPROVED BY THE CITY OF RENTON. LOWER PORTION NOT REPLACED 18-2251 SS-41 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET KING COUNTY CONNECTION DETAIL S 3RD ST & BURNETT AVE S JJM BAW TTT 76NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-41 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 KING COUNTY WASTEWATER TREATMENT DIVISION SEWER NOTES: 1.KING COUNTY SHALL REVIEW AND COMMENT ON THE CONTRACTORS ACCIDENT PREVENTION PROGRAM (APP) PER WAC 296-800-140/296-155-110 AND SITE SPECIFIC/ PROJECT SPECIFIC HEALTH AND SAFETY PLAN (HASP) PER WAC 296-155/WD 27.00. 2.KING COUNTY MANHOLES ARE PERMIT REQUIRED CONFINED SPACES AND ALL APPLICABLE RULES AND REGULATIONS SHALL BE FOLLOWED PRIOR TO ENTRY. 3.NOTIFY MARK LAMPARD AT KING COUNTY (206-477-5414, MARK.LAMPARD@KINGCOUNTY.GOV) A MINIMUM OF FIVE (5) WORKING DAYS IN ADVANCE OF THE PRE-CONSTRUCTION CONFERENCE. 4.CONTRACTOR SHALL NOTIFY MARK LAMPARD AT KING COUNTY (206-477-5414, MARK.LAMPARD@KINGCOUNTY.GOV) A MINIMUM OF THREE (3) WORKING DAYS IN ADVANCE OF ANY CONSTRUCTION ACTIVITY WITHIN 50-FEET OF THE KING COUNTY EASTSIDE INTERCEPTOR. 5.THE CONTRACTOR SHALL TAKE MEASURES TO PROTECT THE EASTSIDE INTERCEPTOR DURING SHORING ACTIVITY. 6.KING COUNTY SHALL REVIEW THE SHORING PLANS. 7.A KING COUNTY REPRESENTATIVE SHALL BE PRESENT AT ALL TIMES ON-SITE DURING EXCAVATION, CORING, AND INSTALLATION OF THE CONNECTION TO THE KING COUNTY EASTSIDE INTERCEPTOR. 8.NO DEBRIS SHALL BE PERMITTED TO ENTER THE KING COUNTY SEWER SYSTEM DURING CONSTRUCTION OF/OR CONNECTION TO THE KING COUNTY EASTSIDE INTERCEPTOR. 9.NO WORK ON OR CONNECTING TO THE KING COUNTY EASTSIDE INTERCEPTOR SHALL BE BACKFILLED UNTIL THE WORK HAS BEEN INSPECTED AND APPROVED BY A KING COUNTY REPRESENTATIVE. 10.THE CONNECTION TO THE KING COUNTY EASTSIDE INTERCEPTOR SHALL NOT BE PUT INTO SERVICE UNTIL ALL NEWLY INSTALLED PIPE HAS BEEN CLEANED, INSPECTED, TESTED, AND APPROVED BY THE CITY OF RENTON. SCALE: 3/8" = 1' - 0" KING COUNTY MANHOLE R01-17 CONNECTION ID = 9'-0"1'-6" 12'-0" 1'-6" C/L 1'-0"VARIESVARIESVARIES1'-0"C/L 90°VARIES1'-0"9 0 °VARIES1'-0"90° R 1'-3" MIN 1'-2" MIN ANGLE RADIUS R 15°-35°17'-0" 35°-55°7'-6" 55°-75°5'-0" 75°-90°4'-6"C/L2 TYP DIMENSIONS FOR DEFLECTION MANHOLE 108 INCH PIPE KING COUNTY AS-BUILT KOR-N-SEAL ADAPTOR W/ EXPANSION BAND POSITIONED TO BEAR ON CONCRETE ON ALL SIDES 20°2 SS-11 NOTES: 1.MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE. 2.ALL JOINTS BETWEEN THE CONE, RISER RINGS, BRICKS AND CASTING SHALL BE PER CITY STD PLAN 106. 3.SANITARY SEWER MANHOLES SHALL HAVE INTERIOR SURFACES, COATED PER CITY STDPLAN 400.1 SCALE: 1/2" = 1' - 0" SSMH #22 SECTION 1 - 29° RELINER DROP BOWL & HOOD. INSTALL BOWL 1" BELOW INLET PIPE SS CLAMPING BRACKET PER CITY STD PLAN 400.1, COORDINATE SIZE WITH 90° BEND FLEX CPLG 90° BEND, PE 24" SDR 35 DROP PIPE EXTEND INLET PIPE 1" BEYOND MH WALL CONCRETE CHANNEL CHANNEL INVERT W/ MIN 0.1-FT FALL TO OUTLET KOR-N-SEAL BOOT KOR-N-SEAL BOOT 6" RUBBER GASKETS, LADDER AND STEPS PER CITY STD PLAN 400.1 60" MANHOLE CONE, ADJUSTMENT RINGS, FRAME AND COVER PER CITY STD PLAN 400.1 AND 106FLAT SLAB TOP CONCRETE BENCH LEVEL WITH CROWN OF OUTLET PIPE, SLOPE 4%90°90°VARIES24" C900 SS 2% SLOPE IE TO MATCH SPRINGLINE OF KC INTERCEPTOR 24" C900 2% SLOPE MIN 6' COMPACTED CSTC SUBGRADE STRUCTURE IN FIELD WAS FOUND TO BE PERPENDICULAR TO ALIGNMENT, ANGLED DRILL WAS NOT REQUIRED 18-2251 SS-42 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET MISCELLANEOUS SEWER DETAILS JJM BAW TTT 77NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-SS-R.dwg SS-42 11/10/2023 11:30 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: NTS NEW SEWER PIPE TIE-IN TO EXISTING SEWER MANHOLE REMOVE EXIST CHANNEL AND RE-CHANNEL WITH NEW CONC FOLLOWING INSTALLATION OF NEW PIPES PER CITY STD PLAN 400.1 GROUT ADAPTER IN PLACE WITH 3000 PSI NON-SHRINK GROUT SANDED PIPE ADAPTER GPK OR EQUAL PIPE SIZE AND MATERIAL AS SHOWN IN PLANS EXIST MH 4" MAX TYP FOUNDATION SCALE: NTS NEW SEWER PIPE TIE-IN TO EXISTING SEWER PIPE STANDARD SANITARY SEWER MANHOLE FRAME AND COVER PER CITY STD PLAN 401 USE ROMAC 501 COUPLINGS OR EQUAL TO CONNECT TO EXIST SEWER MAINLINE RUBBER PIPE ADAPTER KOR-N-SEAL OR EQUAL COMPACTED FOUNDATION 2 - 1 - STANDARD SANITARY SEWER MANHOLE PER CITY STD PLAN 400.1 5' MAX TYP EXISTING SEWER PIPE, TYP NEW SEWER PIPE NOTES: 1.MATCH NEW SEWER PIPE SIZE TO ADJACENT EXISTING SEWER. 2.NEW PIPE STUB SHALL BE SDR 35. •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••3 8 3 7 3 8 3 7 3 639383637 38 353 5 3436 35 34 35 34 3 3 32 31333231293030 31 3233 3 4 3738434 2 41 40 FIRE LANE 35 CRPL#3 66" STL CRPL#1 66" STL CRPL#2 51.5" STL CRPL#3 66" STL CRPL#1 66" STL CRPL#2 51.5" STL CRPL#1 66" STL CRPL#2 51.5" STL CRPL#3 66" STL •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• •••••••••••••••••••••••••••••••••••••••••••••••••••••••• •••• ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••N3+00N4+00A0+00 A1+00 A2+00 A3+00 A4+00 8 " SD R 3 5 S S 8" C900 SS8" SDR 35 SS 8" C900 SS8" SDR 35 SSA0+00 A1+00 A2+00 A3+00 A4+00 STA A0+88, 5' RT 1-POLYPIG 1-TB STA A0+96, 5' RT 1-12"x6" TEE, RJxFL 1-6" GV, FLxRJ 1-FH, 26 LT 1-TB 2-6" 45° BEND, RJ IE=34.01 STA A4+24, 4' RT 1-12" CROSS, FLG 4-12" GV, FLGxRJ IE=23.36 STA A4+14, 20' RT STA Q1+20 STA A4+12 STA Q1+00 STA A0+00, 0' STA A0+00, 10' RT 12"DI W A0+00 A1+00 A2+00 A3+00 A4+00Q0+00Q1+0012"DI W12"DI W 12"DI W 15 20 25 30 35 40 45 50 15 20 25 30 35 40 45 50 A0+00 A0+20 A0+40 A0+60 A0+80 A1+00 A1+20 A1+40 A1+60 A1+80 A2+00 A2+20 A2+40 A2+60 A2+80 A3+00 A3+20 A3+40 A3+60 A3+80 A4+00 A4+20 A4+40 A4+60 A4+80EXIST UGPEXIST 8"W (TBA)PROP 12"WIE=25.3IE=23.412"DI WPROP SS SIDE SEWER4' MINCOVERPROP POLY PIGGING ASSYEXIST GR @ ROW CL MATCHLINE STA A4+80SEE SHEET W-2PROP FHEXIST 24"SDIE=21.0PROP 8"SSIE=25.4PROP SS SIDE SEWER18-2251 W-1 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 2ND ST WATER PLAN & PROFILE STA A0+00 TO STA A4+80 JAM BAW TTT 78NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-W-R.dwg W-1 11/10/2023 10:14 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE S 2ND ST MATCHLINE STA A4+80SEE SHEET W-2RAINIER AVE S1 1 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 POLYPIG STATION IN ACCORDANCE WITH COR STD PLAN 300.6 TEMPORARY WATER SERVICE WITH END CAP AND THRUST RESTRAINT, SEE SHT D-1 SEE SHT W-29 PIPE CONTINUATION FH ASSY PER COR STD PLAN 310.1 EXIST WATER TO BE ABANDONED AND/OR REMOVED, SEE SHT D-1 CONCRETE DEADMAN BLOCKING PER DETAIL ON W-44. TO BE INSTALLED PRIOR TO FINAL CONNECTION 16 TYP LAKE AVE S16 FUTURE 12" WATER MAIN (BY OTHERS) A W-40 SEE SHT W-29 FOR ALIGNMENT Q CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 35 27 34 35 27 27 100144 37 37 ± 392 LF OF 12" CL 52 REST JOINT DI WATER MAIN WITH POLYWRAP CONC MON IN CASE REESTABLISHED PER DNR PERMIT 7373 - 18"T X 6"W IE=19.55 99 IE AT HYDRANT =31.76 IE=31.58 IE=34.30 99 INSTALLED 2-45° BENDS, 3-FT SPOOL, AND ANCHORS TO ROUTE UNDER DUCT BANK RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS STA A0+94 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 31 31 31 31 32 32 3 3 32 32 32 31 32 32 32 NO PARKING FIRE LANE NO PARKINGNO PARKING FIRE LANENO PARKING FIRE LANENO PARKING FIRE LANESTOP NO PARKINGNO PARKINGNO PARKING FIRE LANE3 2 3231 CRPL#3 66" STL CRPL#2 51.5" STL CRPL#3 66" STL CRPL#1 66" STL CRPL # 1 6 6 " S T L •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••FO DUCT E7+00 E8+00 E9+00 A5+00 A6+00 A7+00 A8+00 A9+00 8" C900 SS 8" C900 SS 8" SIDE SEWER2"PVC CONDUIT A5+00 A6+00 A7+00 A8+00 A9+00 STA A6+29, 4' RT 1-12"x6" TEE, RJxFL 1-6" GV, FLxRJ 1-FH, 20' LT 1-TB 2-6" 45° BENDS STA A7+76, 3' LT 1-12" 11.25° BEND, RJ 1-TB STA A9+08, 3' RT 1-12" 11.25° BEND, RJ 1-TB STA A9+41, 12' LT 1-12"x6" TEE, RJxFL 1-6" GV, FLxRJ 1-FH, 32 LT 1-TB STA A9+32, 0' STA A7+59, 16' RT STA A7+36, 0' STA A6+59, 20' RT STA A9+28, 1' LT 1-12" 22.5° BEND, RJ 1-TB STA A9+36, 2' LT 1-12" 22.5° BEND, RJ 1-TB STA A6+07, 4' RT 1-12"X2" TEE 1-2" GV STA A6+14, 4' RT 1-12"X2" TEE 1-2" GV 12"DI W 12"DI W A5+00 A6+00 A7+00 A8+00 A9+00 E2+00 E3+00 E4+00 TS STA A9+22, 9' LT 1-12" INSULATING SLV 10 15 20 25 30 35 40 45 10 15 20 25 30 35 40 45 A4+80 A5+00 A5+20 A5+40 A5+60 A5+80 A6+00 A6+20 A6+40 A6+60 A6+80 A7+00 A7+20 A7+40 A7+60 A7+80 A8+00 A8+20 A8+40 A8+60 A8+80 A9+00 A9+20 A9+40 A9+60EXIST GEXIST TEXIST UGP12"DI W 4' MINCOVEREXIST 12"SDIE=26.5MATCHLINE STA A4+80SEE SHEET W-1MATCHLINE STA A9+60SEE SHEET W-3EXIST GR @ ROW CLPROP FHPROP 8"SS SIDE SEWERPROP 8"SSIE=22.1PROP FHEXIST TEXIST TPROP WS (2)IE=24.9PROP WSIE=26.35EXIST UGPSTA A9+28 1-22.5° VERT BEND, RJ IE=27.0 STA A9+37 1-22.5° VERT BEND, RJ IE=24.0 STA A9+23 1-12" INSULATING SLV INSTALL JOINT BONDS AT ALL JOINTS AND ANODES EVERY 20' 18-2251 W-2 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 2ND ST WATER PLAN & PROFILE STA A4+80 TO STA A9+60 JAM BAW TTT 79NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-W-R.dwg W-2 11/10/2023 10:14 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE S 2ND ST MATCHLINE STA A4+80SEE SHEET W-1MATCHLINE STA A9+60SEE SHEET W-31 TYP 13 TYP OF 2 15 13 13 WATER SERVICE TABLE SERVICE NO.ADDRESS SIZE APPROX STATION AT MAIN FIELD VERIFIED STATION AT MAIN IRRIGATION 2"A9+39, 35' LT A9+43, 35' LT IRRIGATION 1.5"A6+17, 20' LT A6+07, 20' LT WATER SERVICE TABLE SERVICE NO.ADDRESS SIZE APPROX STATION AT MAIN FIELD VERIFIED STATION AT MAIN 200 S 2ND ST 2"A6+10, 30' LT 6+10.5, 30' LT1 2 3 15 15 3 1 2 11 22414211 23 23 1 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 MINIMUM SPACING OF 24" BETWEEN 2" TAPPED TEE FOR WATER SERVICE LINE AND HYDRANT TEE MEASURED EDGE TO EDGE REPLACE EXIST WATER LATERAL SETTER AND METER BOX PER COR STD PLAN 320.3 AND RECONNECT TO EXIST SERVICE FH ASSY PER COR STD PLAN 310.1, CLOSE EXIST HYDRANT VALVE, REMOVE HYDRANT, VALVE COVER, & VALVE BOX, SALVAGE TO COR OR DISPOSE AS DIRECTED BY CITY ENGINEER PROP WATER SERVICES TO AVOID ABANDONED VAULT PROPOSED CORROSION PROTECTION FLUSH MOUNTED TEST STATIONS TYPE FI, SEE CORROSION PROTECTION DETS TEMPORARY WATER SERVICE WITH END CAP AND THRUST RESTRAINT, SEE SHT D-2 EXIST WATER TO BE ABANDONED AND/OR REMOVED, SEE SHT D-2 REPLACE SURVEY MONUMENT PER CITY STD DETAIL H031 AS REQUIRED FOR CONSTRUCTION CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 27 400 200 203 211 26 27 26 ± 480 LF OF 12" CL 52 REST JOINT DI WATER MAIN WITH POLYWRAP 37 37 38 38 IE=27.4 IE=27.6 CONC MON IN CASE REESTABLISHED PER DNR PERMIT 7373 - 18"T X 6"W RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS IE=25.3 STA A6+27 JOINT DEFLECTION THROUGH CURVE JOINT DEFLECTION THROUGH CURVE 11'STA A9+23, 0' RT STA A9+42, 3' LT ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••32 33 33 33 34 33 34 34 33 34 34 33 3333 32 32 NO PARKING FIRE LANECRPL #3 66" STL CRPL#3 66" STL CRPL#3 66" STL FO DUCT FO DUCT FO DUCT FO DUCT A10+00 A11+00 A12+00 A13+00 A14+00 8" SDR 35 SS 8" C900 SS8" SDR 35 SS2"PVC CONDUIT 8" D I S D8"PP SD12"C900 SD 12"DI S D 15"PP SD 8"DI SD 8"DI SD8" D I S D STA A13+15, 4.3' LT 1-SDMH #5.5 12"PP SD 8"DI SD STA A9+84, 16' LT STA F0+84, 13' LT 1-12" TEE, FLG 3-12" GV, FLGxRJ 1-TB STA A11+48, 10' LT = STA S1+00 1-12" TEE, FLG 3-12" GV. FLGxRJ 1-TB 1-12"X8" RDCR 4-45° BENDS STA G-0+04, 9' RT STA A12+78, 4' LT 1-12" 90° BEND, RJ 1-TB STA A9+71, 0' LT STA F1+00, 0'RT STA A12+87 STA G0+00 STA A9+85, 7' LT 1-12" 45° VERT BEND, RJ IE=27.5 STA A9+90, 7' LT 1-12" 45° VERT BEND, RJ IE=24.0 STA A12+64, 4' LT 1-12" 45° BEND, RJ 1-TB STA A14+00, 39' RT 1-12" GV, RJxRJ 2-12" SOLID SLV, RJ IE=26.9 STA A12+86, 39' RT 1-22.5° BEND, RJ 1-TB STA A10+20, 13' LT 1-12" INSULATING SLV STA A12+35, 4' LT 1-12" INSULATING SLV STA A12+30, 4' LT 1-1" AIR RELEASE VALVE STA A12+92, 39' RT 1-22.5° BEND, RJ 1-TB STA A13+04, 39' RT 1-12" INSULATING SLV IE=27.15 STA A12+73, 4' LT 1-12" 45° BEND, RJ 1-TB STA A11+75, 11' LT 1-12" 45° BEND 1-TB IE=26.97 STA A12+43, 4' LT 1-12" GV, RJxRJ STA A11+81, 5' LT 1-12" 45° BEND 1-TB IE=27.05 10'-1"8"DI WF1+0012"DI W12"DI W 12"DI WG0+00A10+00 A11+00 A12+00 A13+00 A14+00 12"DI W TS TS TS TS TS STA A12+78, 39' RT 1-12" TEE, FLG 3-12" GV, FLGxRJ 1-TB 10 15 20 25 30 35 40 45 10 15 20 25 30 35 40 45 A9+60 A9+80 A10+00 A10+20 A10+40 A10+60 A10+80 A11+00 A11+20 A11+40 A11+60 A11+80 A12+00 A12+20 A12+40 A12+60 A12+80 A13+00 A13+20 A13+40 A13+60 A13+80 A14+00 A14+20 A14+40EXIST UGPEXIST UGPEXIST UGPEXIST UGP12"DI WEXIST TEXIST 6"W (TBA)PROP 12"SDIE=36.0PROP 12"SDIE=30.9PROP 12" WIE=26.6PROP 12"WIE=0.0MATCHLINE STA A9+60SEE SHEET W-24' MINCOVEREXIST GR @ ROW CL EXIST 8"W (TBA)EXIST 12"DI WPROP 12"WIE=27.5PROP 8"SSIE=0.0PROP WSEXIST GPROP WSSTA A9+90 1-12" 45° VERT BEND, RJ IE=27.5 STA A9+85 1-12" 45° VERT BEND, RJ IE=24.0 STA A12+64 1-12" 45° VERT BEND, RJ IE=27.6 STA A12+78 1-12" 90°, RJ IE=20.0 STA A12+78 1-12" 22.5° BEND, RJ IE=26.5 STA A12+83 1-12" 22.5° BEND, RJ IE=26.5 STA A12+88 1-12" 22.5° BEND, RJ IE=28.3 INSTALL JOINT BONDS AT ALL JOINTS AND ANODES EVERY 20' STA A10+20 1-12" INSULATING SLV STA A12+35 1-12" INSULATING SLV IE=28.9 STA A13+04 1-12" INSULATING SLV INSTALL JOINT BONDS AT ALL JOINTS AND ANODES EVERY 20' STA A12+73 1-12" 45° VERT BEND, RJ IE=20.0 IE=28.0 IE=19.5 IE=19.5EXIST FO DUCTIE=26.0IE=24.018-2251 W-3 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 2ND ST WATER PLAN & PROFILE STA A9+60 TO STA A14+40 JAM BAW TTT 80NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-W-R.dwg W-3 11/10/2023 1:10 PM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE S 2ND ST MATCHLINE STA A9+60SEE SHEET W-2SHATTUCK AVE S1 TYP FOR CONTINUATION SEE SHEET W-15 FOR CONTINUATION SEE SHEET W-19 15 20 WHITWORTH AVE SD W-40 WATER SERVICE TABLE SERVICE NO.ADDRESS SIZE APPROX STATION AT MAIN FIELD VERIFIED STATION AT MAIN 321 S 2ND ST 1"A12+07, 5' LT A12+09, 16' RT IRRIGATION 2"A13+26 A13+24, 18' RT 1 2 EXIST 6" FIRE SPRINKLER VAULT 1 8 43FOR CONTINUATION SEE SHEET W-30 24 13 2 13 15 8 20 1 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 12" GATE VALVE TO BE CUT IN BY CITY FORCES PRIOR TO ABANDONMENT OF EXIST WATER WATER SERVICES CROSSING SPU SHALL USE KAMCO MUNICIPAL AQUA SHIELD COPPER PIPE PROPOSED CORROSION PROTECTION FLUSH MOUNTED TEST STATIONS TYPE FF, SEE CORROSION PROTECTION DETAILS SHT CP-1 REPLACE EXIST WATER LATERAL SETTER AND METER BOX PER COR STD PLAN 320.3 AND RECONNECT TO EXIST SERVICE FH ASSY PER COR STD PLAN 310.1, CLOSE EXIST HYDRANT VALVE, REMOVE HYDRANT, VALVE COVER, & VALVE BOX, SALVAGE TO COR OR DISPOSE AS DIRECTED BY CITY ENGINEER REPLACE EXIST WATER LATERAL AND METER PER COR STD PLAN 320.1 AND RECONNECT TO EXIST SERVICE WATER SERVICE TO BE INSTALLED WITH A 2" SADDLE TAP PRIOR TO ABANDONMENT OF 8" WATER BETWEEN SHATTUCK AVE S AND WHITWORTH AVE S PROPOSED CORROSION PROTECTION FLUSH MOUNTED TEST STATIONS TYPE FI, SEE CORROSION PROTECTION DETAILS, SHT CP-1 TEMPORARY WATER SERVICE WITH END CAP AND THRUST RESTRAINT, SEE SHT D-3 SEE SHT W-19 FOR PIPE CONTINUATION SEE SHT W-30 FOR PIPE CONTINUATION SEE SHT W-30 FOR PIPE CONTINUATION AIR RELEASE VALVE PER COR STD PLAN 340.3 EXIST WATER TO BE ABANDONED AND/OR REMOVED, SEE SHT D-3 24 CONNECT TO EXIST 6" WATER SEE SHT W-30 FOR PLAN & PROFILE CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20'7926 6 6 9 29 28 28 30 6 26 26 9 27 36 27 26 27 28 29 30 36 ± 320 LF OF 12" CL 52 REST JOINT DI WATER MAIN WITH POLYWRAP 37 37 IE=26.9 PROVIDE TEMPORARY SUPPORT AND PROTECT EXISTING FO DUCT DURING CONSTRUCTION IE=26.35 IE=19.16 18" COR CREWS INSTALLED 12/9/2021 1'-6" NIPPLE TO 12" SLEEVE 5 FT TO TOP OF PIPE 33" 33" NIPPLE BETWEEN SLEEVES. 4'-9"TO TOP OF PIPE RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS STA A11+42, 6' LT IE=26.62 FOUND PREVIOUSLY UNKNOWN LUMEN FO DUCT STA A12+57, 5' LT 5' LT 5' LT 5' LT 5' LT STA G-0+05 7' LT F0+93, 9' LT A9+80, 7' LT ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••323333323232 32 32 32 31 3 2 CRPL#2 51.5" STLCRPL#1 66" STLCRPL#3 66" STLCRPL#1 66" STLCRPL#2 51.5" STL•••••••••••••••••••FO DUCTFO DUCTF1+00 F2+00 F3+00 F4+00 F5+00 8" SDR 35 SS8" SDR 35 SS2"PVC CONDUIT18" PP SD 18" PP SD 18" PP SD12"PP SD12"PP SD12"PP SD15"PP SD8" DI SDSTA F0+84, 13' LT 1-12" TEE, FLG 1-12" GV, FLGxFLG 2-12" GV, FLGxRJ 1-TB STA F1+41, 11' LT 1-12" GV, RJ 1-TB STA F1+83, 10' LT 1-12" 45° BEND, RJ 1-TB STA F1+88, 10' LT 1-12" 45° BEND, RJ 1-TB STA F2+23, 9' LT 1-12" 45° BEND, RJ 1-TB STA F2+32, 9' LT 1-12" 45° BEND, RJ 1-TB STA F2+40, 8' LT 1-12" 45° BEND, RJ 1-TB, IE=27.0 STA F2+45, 13' LT 1-12" 45° BEND, RJ 1-TB, IE=27.2 STA F0+95, 38' RT STA F4+05, 12' LT 1-12"x4" TEE, FLGxRJ 1-4" GV, FLGxRJ 1-TB STA F6+08, 11' LT 1-12" 22.5° BEND, RJ COMPOUND BEND 1-TB STA F1+76, 10' LT 1-12"x6" TEE, RJxFL 1-6" GV, FLxRJ 1-FH, 24' LT 1-12" GV, RJ 1-TB STA F6+03, 11' LT 1-12"x6" TEE, RJxFL 1-6" GV, FLxRJ 1-FH, 24 LT 1-TB STA F1+16, 12' LT 1-12" 45° BEND, RJ 1-TB, 1-DEADMAN STA F3+10, 9' LT 1-12"x6" TEE, RJxFL 1-6" GV, FLxRJ 1-FH, 24' LT 1-12" GV, RJ 1-TB, IE=27.5 STA F1+66, 11' LT 1-1" AIR RELEASE VALVE STA F4+04, 18' RT 1-4" 45° BEND, RJ 1-TB STA F4+09, 23' RT 1-4" 45° BEND, RJ 1-TB STA F6+14, 11' LT 1-12" 22.5° BEND, RJ 1-TB F1+00 F2+00 F3+00 F4+00 F5+00 12"DI W12"DI W12"DI W12"DI WTSTS TSTS TSTS STA F2+65, 13' LT 1-12" INSULATING SLV IE=27.5 STA F1+24, 12' LT 1-12" 45° BEND, RJ 1-TB, 1-DEADMAN STA F1+02, 8' LT 1-12" 45° BEND, RJ 1-TB 1-DEADMAN STA F0+97, 8' LT 1-12" 45° BEND, FLGxRJ 1-TB 1-DEADMAN 15 20 25 30 35 40 45 15 20 25 30 35 40 45 F0+80 F1+00 F1+20 F1+40 F1+60 F1+80 F2+00 F2+20 F2+40 F2+60 F2+80 F3+00 F3+20 F3+40 F3+60 F3+80 F4+00 F4+20 F4+40 F4+60 F4+80 F5+00 F5+20 F5+40 F5+60 F5+80 45° BEND MOVED TO DROP BELOW FOUND FO DUCT, CASING EXTENDED APPROX 21' LONG CASING APPROX 15' LONG CASING 12"DI WEXIST TEXIST 66"W (SPU)CROWN= 28.8, IE=23.3EXIST UGP (3)EXIST 51.5"W (SPU)CROWN=29.7, IE=25.4EXIST 12" SD (TBA)PROP 12" WIE=26.6EXIST 66"W (SPU)CROWN=29.5, IE=24.0EXIST T(2)PROP WSEXIST UGPEXIST UGPTO BE RELOCATEDPROP 12" SDIE=30.5PROP 12" SDIE=29.4PROP SS SIDE SEWEREXIST GR @ ROW CL MATCHLINE STA F5+80SEE SHEET W-164' MINCOVER2'MINSTA F0+86 1-12" 45° BEND, FLGxRJ IE=26.7 STA F1+83 1-12" 45° VERT BEND, RJ IE=26.4 STA F2+23 1-12" 45° VERT BEND, RJ IE=20.4 STA F2+32 1-12" 45° VERT BEND, RJ IE=27.0 STA F1+24 1-12" 45° BEND, RJ IE=26.42'MINPROP WS (3)24"STEEL CASING, LTFPROP FHPROP 12" SDIE=29.4EXIST 8"SDSTA F1+88 1-12" 45° VERT BEND, RJ IE=20.3PROP 12" SDIE=27.3PROP 12" SSIE=20.8PROP WS24"STEEL CASING, LTF STA F0+94 1-12" 45° BEND, RJ IE=19.5 STA F1+16 1-12" 45° BEND, RJ IE=19.5 PROP SS SIDE SEWERPROP FHSTA F2+65 1-12" INSULATING SLV INSTALL JOINT BONDS AT ALL JOINTS AND ANODES EVERY 20' IE=24.0 IE=24.0 IE=24.4 IE=19.5 IE=19.8 IE=26.3EXIST FO DUCTF1+02 F0+95 18-2251 W-15 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET SHATTUCK AVE S WATER PLAN & PROFILE STA F0+00 TO STA F5+80 JAM BAW TTT 81NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-W-R.dwg W-15 11/10/2023 10:14 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILES 2ND STMATCHLINE STA F5+80SEE SHEET W-16SHATTUCK AVE S 1 TYP TYP OF 3 20 21 FOR CONTINUATION SEE SHEET W-2 FOR CONTINUATION SEE SHEET W-3 WATER SERVICE TABLE SERVICE NO.ADDRESS SIZE APPROX STATION AT MAIN 211 SHATTUCK AVE S 4"F4+09, 27' RT 305 S 2ND ST 1"F1+70, 28' LT 309 S 2ND ST 1"F1+71, 28' LT 315 S 2ND ST 1"F1+72, 28' LT 220 SHATTUCK AVE 1"F3+58, 24' LT 1 2 3 4 5 4 2 3 4 495012 542014 5 1 15 9 26 12 15 3 4 20 1 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 REMOVE AND REPLACE EXIST STORM TO A DISTANCE OF 10 FT ON BOTH SIDES OF PROP WATER, STORM PIPE SHALL BE C900 PVC AND SHALL MATCH EXIST SLOPE, SIZE, AND ALIGNMENT SUPPORT SPU WATER IN PLACE PER 1-07.17, DO NOT ALLOW EXIST PEA GRAVEL BACKFILL TO UNRAVEL, BACKFILL PIPE BEDDING PER SPU STD PLAN 350 PROPOSED CORROSION PROTECTION FLUSH MOUNTED TEST STATIONS TYPE FF, SEE CORROSION PROTECTION DETAILS, SHT CP-1 CASING PIPE SHALL CONFORM TO STD 412, SPU SUPPORT DETAILS IN APPENDIX A WATER SERVICES CORP CONNECTIONS SHALL BE A MIN OF 18" FROM OTHER SERVICES OR FITTINGS FH ASSY PER COR STD PLAN 310.1, CLOSE EXIST HYDRANT VALVE, REMOVE HYDRANT, VALVE COVER, & VALVE BOX, SALVAGE TO COR OR DISPOSE AS DIRECTED BY CITY ENGINEER REPLACE EXIST WATER LATERAL AND METER PER COR STD PLAN 320.1 AND RECONNECT TO EXIST SERVICE REPLACE EXIST WATER LATERAL AND METER PER COR STD PLAN 320.4 AND RECONNECT TO EXIST SERVICE PROPOSED CORROSION PROTECTION FLUSH MOUNTED TEST STATIONS TYPE FI, SEE CORROSION PROTECTION DETS, SHT CP-1 TEMPORARY WATER SERVICE WITH END CAP AND THRUST RESTRAINT, SEE SHT D-15 SEE SHT W-2 FOR PIPE CONTINUATION FH ASSY PER COR STD PLAN 310.1 AIR RELEASE VALVE PER COR STD PLAN 340.3 EXIST WATER TO BE ABANDONED AND/OR REMOVED, SEE SHT D-15 CONCRETE DEADMAN BLOCKING PER DETAIL ON W-44. TO BE INSTALLED PRIOR TO FINAL CONNECTION 21 14 9 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20'375253553 26 26 27 35 31 26 27 31 35 36 211 212 300220 37 36 37 ± 490 LF OF 12" CL 52 REST JOINT DI WATER MAIN WITH POLYWRAP 1-11.25° BEND IE=23.2 IE=17.9 99 F2+43 IE=27.9 IE=26.5 IE=25.4 1-4"x4" TEE, RJ 2-4" GV 2-4" 45° BEND 2-TB 36" DEEP RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS 99 8' LT 8' LT 99 •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••3131 31 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••8" SDR 35 SS 18" PP SD 24" PP SD18" PP SD24" PP SD 24" PP SD 24" PP SD12"PP SD12"PP SD12"D I S D 12"DI S D 12"C900 SD12"C900 SD1 2 "C 9 0 0 SD STA F6+44, 5' LT 1-12" PLUG, RJ 1-TB STA F6+44, 13' LT 1-12" TEE, FLGxRJ (CUT-IN) 1-12" GV, FLGxRJ 2-12" SOLID SLV, RJ 1-TB STA F6+08, 11' LT 1-12" 22.5° BEND, RJ COMPOUND BEND 1-TB STA F6+34, 13' LT 1-12" 22.5° BEND, RJ 1-TB STA F6+39, 13' LT 1-12" 22.5° BEND, RJ 1-TB STA F6+03, 11' LT 1-12"x6" TEE, RJxFL 1-6" GV, FLxRJ 1-FH, 24 LT 1-TB STA F6+44, 10' RT 1-12" GV, RJ 2-12" SOLID SLV, RJ STA F6+14, 11' LT 1-12" 22.5° BEND, RJ 1-TB F6+00 F7+00 F8+00 F9+00 F10+00 12"DI W STA F6+45, 40' RT 1-6" SPL, LTF 1-FH, STA F6+79, 40' RT 10 15 20 25 30 35 40 10 15 20 25 30 35 40 F5+80 F6+00 F6+20 F6+40 F6+60 F6+80 F7+00 F7+20 F7+40 F7+60 F7+80 F8+00 F8+20 F8+40 F8+60 F8+80 F9+00 F9+20 F9+40 F9+60 F9+80 F10+00 F10+20 F10+40 F10+60 12"DI W CONNECT TOPROP 12"WEXIST 12" SD(TO BE REPLACED)IE=26.0EXIST UGPPROP FHEXIST COMEXIST SS (TBA)IE=25.6MATCHLINE STA F5+80SEE SHEET W-15MATCHLINE STA F10+60SEE SHEET W-17EXIST GR @ ROW CL STA F6+08 1-12" 22.5° VERT BEND, RJ IE=25.9 STA F6+14 1-12" 22.5° COMPOUND BEND, RJ IE=23.5 STA 6+34 1-12" 22.5° COMPOUND BEND, RJ IE=23.5 STA 6+39 1-12" 22.5° VERT BEND, RJ IE=25.7 EXIST 12"W4' MINCOVER4"18-2251 W-16 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET SHATTUCK AVE S WATER PLAN & PROFILE STA F4+80 TO STA F10+60 JAM BAW TTT 82NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-W-R.dwg W-16 11/10/2023 10:14 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILES 3RD STMATCHLINE STA F10+60SEE SHEET W-17SHATTUCK AVE S MATCHLINE STA F5+80SEE SHEET W-151 TYP 15 10 S 3RD PLG W-41 565710 15 5 1 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 REMOVE AND REPLACE CATCH BASIN (TYPE 1), REMOVE AND REPLACE EXIST STORM PIPE FROM CATCH BASIN TO 10 FT PAST PROP WATER, STORM PIPE SHALL BE C900 PVC AND SHALL MATCH EXIST SLOPE, SIZE, AND ALIGNMENT CONNECT TO EXIST MAIN W/ CUT-IN TEE & VALVE PER COR STD PLAN 300.2 FIRE HYDRANT ASSEMBLY PER COR STD PLAN 310.1. CLOSE EXIST HYDRANT VALVE, REMOVE HYDRANT, VALVE COVER, & VALVE BOX. SALVAGE TO COR OR DISPOSE AS DIRECTED BY CITY ENGINEER EXIST WATER TO BE ABANDONED AND/OR REMOVED, SEE SHT D-16 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 5 301 220 207 ± 65 LF OF 12" CL 52 REST JOINT DI WATER MAIN WITH POLYWRAP 37 37 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHROUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS IE=22.7 CONC MON IN CASE REESTABLISHED PER DNR PERMIT 7373 - 18"T X 6"W HYDRANT AND 6" SPOOL REPLACED BY CITY TO EXIST 6" GV 5/25/20228'-5"102" OF 12" DI FROM GV TO SLEEVE. 5' TO TOP OF PIPE 5' TO TOP OF PIPE 1'-6"5' TO TOP OF PIPE 2'TOP OF SD=24.3 NO W DEFLECTION REQUIRED 5' RT •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••3434333433 3333 33 33 CRPL #2 51.5" STLCRPL#3 66" STLCRPL#1 66" STL••••••••••••••••••••••••••••••••••••••FO DUCTFO DUCTFO DUCTG0+00 G1+00 G2+00 G3+00 8" C900 SS8" C900 SS8" SDR 35 SS12" PP SD 8"DI SD8 " D I SD12"DI SD8"DI SD STA A13+15, 4.3' LT 8"DI SDSTA G-0+05, 9' RT 1-12" 90° BEND, RJ 1-TB STA G0+20, 9' RT 1-12" 45° BEND, RJ 1-TB STA G0+39, 9' RT 1-12" TEE, FLG 3-12" GV, FLGxRJ 1-TB STA G0+69, 9' RT 1-12"x6" TEE, RJxFL 1-6" GV, FLxRJ 1-FH, 24 LT 1-TB IE=27.0 STA G0+27, 9' RT 1-12" 45° BEND, RJ 1-TB STA G0+00, 0' RT STA A12+87, 0' RT STA G1+82, 8' RT 1-12" 45° BEND, RJ 1-TB STA G1+90, 8' RT 1-12" 45° BEND, RJ 1-TB STA G2+24, 8' RT 1-12" 45° BEND, RJ 1-TB STA G2+32, 8' RT 1-12" 45° BEND, RJ 1-TB STA G2+59, 8' RT 1-12" 90° BEND, FLGxRJ 1-12" DI SPL, LTF 1-12" TAPPING GV, FLG 2-TB 1-12" TAPPING TEE, FLG STA G2+56, 8' RT INSULATING SLV 12"DI W 12"DI WG0+00 G1+00 G2+00 G3+00 12"DIWTSTSTSTS TS TS STA G0+37, 27' LT 1-12"x2" TEE 1-2" GV STA S0+94 10 15 20 25 30 35 40 45 10 15 20 25 30 35 40 45 G-0+20 G0+00 G0+20 G0+40 G0+60 G0+80 G1+00 G1+20 G1+40 G1+60 G1+80 G2+00 G2+20 G2+40 G2+60 G2+80 G3+00 G3+20 APPROX 15' LONG CASING APPROX 15' LONG CASING EXIST 12"W 12"DI W EXIST 66"W (SPU)CROWN=29.7, IE=24.2EXIST 51.5"W (SPU)CROWN=30.3, IE=26.0EXIST 12"SDIE=28.5EXIST 6"SD (TBA)IE=28.9PROP 8"SSIE=19.3EXIST 12"SD (TBA)IE=28.4EXIST UGP (3)EXIST UGPEXIST UGP (3)EXIST 6"SD (TBA)IE=29.8EXIST 66"W (SPU)CROWN=28.7, IE=23.2PROP FHMATCHLINE STA G3+20SEE SHEET W-20EXIST GR @ ROW CL 2'MINSTA G0+27 1-12" 45° VERT BEND, RJ IE=27.2 STA G0+20 1-12" 45° VERT BEND, RJ IE=20.0 STA G1+90 1-12" 45° VERT BEND, RJ IE=20.5 STA G1+82 1-12" 45° VERT BEND, RJ IE=26.4 STA G2+24 1-12" 45° VERT BEND, RJ IE=20.5 STA G2+31 1-12" 45° VERT BEND, RJ IE=25.52'MIN4' MINCOVEREXIST 8"W (TBA)PROP 12"SDIE=30.9PROP 12"WIE=0.0PROP WSCONNECT TOEXIST 12"WIE=26.624" STEEL CASING, LTF 24" STEEL CASING, LTFEXIST UGP & TPROP 12"WIE=26.5INSTALL JOINT BONDS AT ALL JOINTS AND ANODES EVERY 20' STA G2+55 1-12" INSULATING SLVEXIST GIE=19.5 IE=26.5 IE=27.5 IE=26.6 18-2251 W-19 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET WHITWORTH AVE S WATER PLAN & PROFILE STA G0+00 TO STA G3+20 JAM BAW TTT 83NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-W-R.dwg W-19 11/10/2023 10:14 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE WHITWORTH AVE S MATCHLINE STA G3+20SEE SHEET W-201 TYP 20 17 15 FOR CONTINUATION SEE SHEET W-3 S 2ND ST12"DI W 24 WATER SERVICE TABLE SERVICE NO.ADDRESS SIZE APPROX STATION AT MAIN FIELD VERIFIED STATION AT MAIN 319 S 2ND ST 1"G1+29 G1+291 4 E W-41 8 125960586119 1 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 REMOVE AND REPLACE EXISTING STORM TO A DISTANCE OF 10 FT ON BOTH SIDE OF PROP WATER, STORM PIPE SHALL BE C900 PVC AND SHALL MATCH EXISTING SLOPE, SIZE, AND ALIGNMENT SUPPORT SPU WATER IN PLACE PER 1-07.17, DO NOT ALLOW EXIST PEA GRAVEL BACKFILL TO UNRAVEL. BACKFILL PIPE BEDDING PER SPU STD PLAN 350 GAS TO BE RELOCATED PRIOR TO CONSTRUCTION WATER SERVICES CROSSING SPU SHALL USE KAMCO MUNICIPAL AQUA SHIELD COPPER PIPE PROPOSED CORROSION PROTECTION FLUSH MOUNTED TEST STATIONS TYPE FF, SEE CORROSION PROTECTIONS DETAILS SHT CP-1 CASING PIPE SHALL CONFORM TO STD 412 SPU SUPPORT DETAILS IN APPENDIX A FIRE HYDRANT ASSEMBLY PER COR STD PLAN 310.1, CLOSE EXIST HYDRANT VALVE, REMOVE HYDRANT, VALVE COVER, & VALVE BOX, SALVAGE TO COR OR DISPOSE AS DIRECTED BY CITY ENGINEER CONNECT TO EXIST MAIN W/TAPPING TEE & VALVES PER COR STD PLAN 300.1 REPLACE EXIST WATER LATERAL AND METER PER COR STD PLAN 320.1 AND RECONNECT TO EXIST SERVICE WATER SERVICE TO BE INSTALLED WITH A 2" SADDLE TAP PRIOR TO ABANDONMENT OF 8"W BETWEEN SHATTUCK AVE S AND WHITWORTH AVE S PROPOSED WATER MAY HAVE A CONFLICT WITH EXISTING UTILITY TO BE ABANDONED, CONTRACTOR SHALL TAKE APPROPRIATE MEASURE TO INSTALL THE WATER UTILITY SUCH THAT FUNCTIONALITY OF THE EXISTING UTILITY IS MAINTAINED UNTIL SUCH TIME AS IT IS ABANDONED PROPOSED CORROSION PROTECTION FLUSH MOUNTED TEST STATIONS TYPE FI, SEE CORROSION PROTECTION DETAILS, SHT CP-1 TEMPORARY WATER SERVICE, SEE SHT D-19 SEE SHT W-3 FOR PIPE CONTINUATION EXISTING WATER TO BE ABANDONED AND/OR REMOVED, SEE SHT D-19 4 8 12 15 17 3 7 20 24 25 9 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' EXIST DEADMAN BLOCK 147 3 26 9 26 32 12 32 26 26 27 220 215 319 321 32 37 32 37 D W-40 CONNECT TO EXIST 12" W ± 265 LF OF 12" CL 52 REST JOINT DI WATER MAIN WITH POLYWRAP RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHOUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS IE=26.4 IE=19.2 6' TO TOP OF 90 FROM INSULATING SLEEVE TO 90 IS 26" FROM 90 TO 12" TAPPING VALVE IS 50" 6' TO TOP OF PIPE 2'- 2 "4'-2" •••••••••••••••••••••••••33333333 33••••••24" C900 SS24" C900 SS8" C900 SS 18" PP SD18" PP SD12" PP SD 12" PP SD 12"D I S D 12"DI SD12"DI SDSTA G5+45, 6' LT 1-12"x12" TEE, FLGxRJ (CUT-IN) 1-12" GV, FLGxRJ 1-TB 3-12" SOLID SLV, RJ 1-12" GV, RJxRJ STA G6+25, 6' LT 1-12"x6" TEE, FLGxRJ 1-12" PLUG, RJ 2-TB 1-4" GV, FLGxRJ STA G6+24, 15' LT 1-6" 90° BEND, RJ 1-6" SOLID SLV, RJ 1-TB STA G5+58, 6' LT 1-12" 11.25° BEND, RJ 1-TB STA G5+63, 6' LT 1-12" 11.25° BEND, RJ 1-TB STA G5+79, 6' LT 1-12" 11.25° BEND, RJ 1-TB STA G5+85, 6' LT 1-12" 11.25° BEND, RJ 1-TB G4+00 G5+00 G6+00 12"DI W 15 20 25 30 35 40 45 15 20 25 30 35 40 45 G3+20 G3+40 G3+60 G3+80 G4+00 G4+20 G4+40 G4+60 G4+80 G5+00 G5+20 G5+40 G5+60 G5+80 G6+00 G6+20 G6+40 G6+60CONNECT TOEXIST 12" W12"DI WPROP 24" SSIE=15.5EXIST GEXIST UGP (2)EXIST GR @ ROW CL MATCHLINE STA G3+20SEE SHEET W-194' MINCOVEREXIST 4"W STA G5+63 1-12" 11.25° VERT BEND, RJ IE=26.2 STA G5+58 1-12" 11.25° VERT BEND, RJ IE=27.8 STA G5+85 1-12" 11.25° VERT BEND, RJ IE=27.8 STA G5+79 1-12" 11.25° VERT BEND, RJ IE=26.2 EXIST G18-2251 W-20 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET WHITWORTH AVE S WATER PLAN & PROFILE STA G3+20 TO STA G6+00 JAM BAW TTT 84NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-W-R.dwg W-20 11/10/2023 10:14 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE WHITWORTH AVE S MATCHLINE STA G3+20SEE SHEET W-19S 3RD ST1 TYP H W-41 62631 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 EXIST WATER TO BE ABANDONED AND/OR REMOVED, SEE SHT D-20 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 400 322 321 325 401 ± 80 LF OF 12" CL 52 REST JOINT DI WATER MAIN WITH POLYWRAP 37 CONNECT TO EXIST 6" W H W-41 37 4" 1-12"x4" TEE RT RT 1-4" 90° BEND 1-4" SOLID SLV IE=27.7 RT STA G5+46, 30' RT 1-6" SPL, LTF 1-FH, STA G5+81, 31 RT HYDRANT AND 6" SPOOL REPLACED BY CITY TO EXIST 6" GV ON 9/2/2021 RT RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHOUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS DID NOT INSTALL BENDS RT RT ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••46 454644 45 4544 4 4 45 46 4 343 CRPL#3 66" STL CPPL#3 66" STLL0+00L1+00 L2+00 L3+00 L4+0012" C900 SS8" SDR 35 SS12" CIPP SSC 9 0 0C900 12"PP SD24"C900 SDSTA L4+75, 11' RT 1-12"x6" TEE, RJxFL 1-6" GV, FLxRJ 1-FH, 29' RT 1-12" GV, RJ 1-TB STA L4+25, 11' LT 1-12" 45° BEND, RJ ROTATED DOWN 1-TB STA L3+96, 0' RT STA L3+98, 11' LT 1-12" CROSS, RJxFLG 2-12" GV, RJxFLG 2-12" INSULATING SLV, RJ IE=39.9 STA L4+03, 11' LT 1-12" 45° BEND, RJ 1-TB STA L4+07, 11' LT 1-12" 45° BEND, RJ 1-12" INSULATING SLV, RJ 1-TBSTA L2+02, 10' LT 1-12"x8" TEE, RJxFLG 1-12" GV, RJ 2-8" 45° BENDS, RJ 1-8" SOLID SLV, RJ 1-8" GV, RJxFLG 3-TB STA L0+40, 0' 1-12" SOLID SLV, RJ 1-12"x8" RDCR, RJ STA L0+83, 10' LT 1-12" 45° BEND, RJ 1-12" GV, RJ 1-TB STA L4+50, 11' RT 1-12" 45° BEND, RJ 1-TB IE=38.9 STA L4+18, 11' LT 1-12" 22.5° BEND, RJ 1-TB STA L3+60, 11' LT 1-12" INSULATING SLV STA L4+71, 11' RT 1-12" INSULATING SLV STA L1+46, 10' LT 1-12"X2" TEE 1-2" GV STA L1+11, 24' RT 1-12"X8" TEE, RJxFL (ROLLED DOWN) 1-8" 45° BEND, RJ 1-8" 90° BEND, RJ 1-8" SOLID SLV, RJ 1-12" PLUG, RF 1-TB 1-DEADMAN ON EXIST WATER MAIN STA L1+35, 10' LT 1-12" 45° BEND, RJ 1-12" GV, RJ 1-TB IE=37.9 L0+00L1+00 L2+00 L3+00 L4+00 12"DI W TS TS TS 25 30 35 40 45 50 55 25 30 35 40 45 50 55 L0+00 L0+20 L0+40 L0+60 L0+80 L1+00 L1+20 L1+40 L1+60 L1+80 L2+00 L2+20 L2+40 L2+60 L2+80 L3+00 L3+20 L3+40 L3+60 L3+80 L4+00 L4+20 L4+40 L4+60 L4+80 12"DI WEXIST GEXIST TABAN WEXIST UGP/FOEXIST GPROP SSIE=38.3PROP 12" W CROSSEXIST TPROP 24" SDIE=39.1EXIST TPROP CIPPIE=0.0EXIST UGPEXIST 66" W (SPU)CROWN=37.9, IE=32.4EXIST TSTA L4+03 1-12" 45° VERT BEND, RJ IE=39.5 MATCHLINE STA L4+80SEE SHEET W-264' MINCOVEREXIST GR @ ROW CL STA L4+07 1-12" 45° VERT BEND, RJ IE=37.5 PROP FHSTA L4+18 1-12" 22.5° BEND, RJ IE=37.5EXIST 8"WEXIST 6"SD(TO BE REPLACED)IE=41.7EXIST TPROP 12" SDIE=41.4PROP WSPROP WSPROP WSPROP SS SIDE SEWEREXIST SS SIDE SEWER6" MINSTA L4+25 1-12" 45° COMPOUND BEND, RJ IE=39.312" MIN6" MIN6" MINPROP 8"WCONNECT TO EXIST 8" W6" MININSTALL JOINT BONDS AND ANODES FOR EACH PIPE LENGTH AND FITTING STA L3+60 1-12" INSULATING SLV STA L4+71 1-12" INSULATING SLVSTA L1+11 1-8" 45° COMPOUND BEND, RJ 1-8" 90° COMPOUND BEND, RJ IE=MATCH EXIST WATER INVERTCONNECT TO EXIST 8" WEXIST TEXIST TEXIST 6"SDCONNECT TO EXIST 8" WPROP WSIE=40.5 IE=37.0 IE=37.0 IE=40.0 18-2251 W-25 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET MILL AVE S WATER PLAN & PROFILE STA L0+00 TO STA L4+80 JAM BAW TTT 85NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-W-R.dwg W-25 11/28/2023 3:18 PM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE MILL AVE S MATCHLINE STA L4+80SEE SHEET W-261 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 SEE SHT G-6 FOR STATION CL NORTHING AND EASTINGS REMOVE AND REPLACE EXIST STORM TO A DISTANCE OF 10 FT ON BOTH SIDES OF PROP WATER, STORM PIPE SHALL BE C900 PVC AND SHALL MATCH EXIST SLOPE, SIZE, AND ALIGNMENT SUPPORT SPU WATER IN PLACE PER 1-07.17, DO NOT ALLOW EXIST PEA GRAVEL BACKFILL TO UNRAVEL, BACKFILL PIPE BEDDING PER SPU STD PLAN 350 PROPOSED CORROSION PROTECTION FLUSH MOUNTED TEST STATIONS TYPE FF, SEE CORROSION PROTECTION DETS REPLACE EXISTING WATER LATERAL SETTER AND METER BOX PER COR STD PLAN 320.3 AND RECONNECT TO EXIST SERVICE WATER SERVICES CORP CONNECTIONS SHALL BE A MIN OF 18" FROM OTHER SERVICES OR FITTINGS PLACE DENSE FOAM CUSHION AT ALL UTILITY CROSSINGS WHERE WATERMAIN CROSSES WITHIN 6" ABOVE/BELOW ANOTHER UTILITY REPLACE EXIST WATER LATERAL AND METER PER COR STD PLAN 320.1 AND RECONNECT TO EXIST SERVICE PROPOSED CORROSION PROTECTION FLUSH MOUNTED TEST STATIONS TYPE FI, SEE CORROSION PROTECTION DETS, SHT CP-1 EXIST WATER TO BE ABANDONED AND/OR REMOVED, SEE SHT D-25 REPLACE SURVEY MONUMENT PER CITY STD DETAIL H031 AS REQUIRED FOR CONSTRUCTION CONDUCT SITE SPECIFIC UTILITY POTHOLING IN ADVANCE OF CONSTRUCTION TO CONFIRM LOCATION AND ELEVATION OF EXIST UTILITY CONCRETE DEAD MAN BLOCKING PER DETAIL ON W-44. TO BE INSTALLED PRIOR TO FINAL CONNECTION 4 13 20 13 K W-42 L W-42 2 14 20 WATER SERVICE TABLE SERVICE NO.ADDRESS SIZE APPROX STATION AT MAIN FIELD VERIFIED STATION AT MAIN IRRIGATION 1.5"L1+46, 10' LT L1+46, 10' LT 1023 BRONSON WAY 1"L2+45, 11' LT L2+45, 23' RT 1010 BRONSON WAY 1"L2+93, 11' LT L2+93, 23' RT 1 2 3 19 4 1 656466676869701 2 3 S 2ND ST26 9 B RON SON W A Y S CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20'719 26 9 3 3 2 19 1023 1010 100 ± 345 LF OF 12" CL 52 REST JOINT DI WATER MAIN WITH POLYWRAP 37 CONNECT TO EXIST 8" W CONNECT TO EXIST 12" W 37 38 38 13 K W-42 APPROXIMATE LOCATION OF BRIDGE APPROACH SLAB IE=41.25 14 98 99 3 CONC. MON. IN CASE REESTABLISHED PER DNR PERMIT 7373 - 18"T X 6"W CAP EXIST TEE 98 99 460 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHOUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS 19 11" ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••4 7 47 4 7 48 4 9 5 3 5 2 5 1 50 4 9 48 4 74747 46 46 46 46 46 45 CRPL#3 66" STLCRPL#3 66" STL CRPL#3 66" STL CRPL#3 66" STL L5+00 L6+00 L7+00 L8+00 L9+00L9+00 134 LF 12" CIPP SS284 LF 12" CIPP SS 12" PP SD 12"PP SD 8"C900 SD8"C900 SD8"DI SD STA L8+13, 11' RT 1-12" 45° BEND, RJ 1-TB IE=40.2 STA L8+23, 21' RT 1-12" 45° BEND, RJ 1-TB IE=39.3 STA L8+39, 23' RT 1-12" 45° BEND, RJ 1-12" SOLID SLV, RJ 1-TB STA L8+47, 17' RT 1-24"x12" TEE, FLG (TAPPING) 1-12" GV,FLGxRJ 1-TB IE=37.0 STA L8+19, 1' LT L5+00 L6+00 L7+00 L8+00 L9+00L9+00 12"DI W 12"DI W 12"DI W STA L7+50, 11' RT 1-12"x6" TEE, RJxFL 1-6" GV, FLxRJ 1-FH, 29' RT 1-TB 25 30 35 40 45 50 55 25 30 35 40 45 50 55 L4+80 L5+00 L5+20 L5+40 L5+60 L5+80 L6+00 L6+20 L6+40 L6+60 L6+80 L7+00 L7+20 L7+40 L7+60 L7+80 L8+00 L8+20 L8+40 L8+60 L8+80 L9+00 12"DI W EXIST TEXIST UGPEXIST 8"SDIE=42.9CONNECT TOEXIST 24" WPROP FHMATCHLINE STA L4+80SEE SHEET W-25EXIST GR @ ROW CL 4' MINCOVERABAN SS SIDE SEWERABAN SS SIDE SEWERABAN SS SIDE SEWERABAN SS SIDE SEWERABAN SS SIDE SEWERPROP 8"SDIE=42.8PROP 8"SDIE=42.212"DI W 18-2251 W-26 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET MILL AVE S WATER PLAN & PROFILE STA L4+80 TO STA L9+00 JAM BAW TTT 86NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-W-R.dwg W-26 11/10/2023 10:14 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE MILL AVE S HOUSER WAY SMATCHLINE STA L4+80SEE SHEET W-251 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 REMOVE AND REPLACE CATCH BASIN (TYPE 1), REMOVE AND REPLACE EXIST STORM PIPE FROM CATCH BASIN TO 10 FT PAST PROP WATER, STORM PIPE SHALL BE C900 PVC AND SHALL MATCH EXIST SLOPE, SIZE, AND ALIGNMENT REPLACE EXIST WATER LATERAL SETTER AND METER BOX PER COR STD PLAN 320.3 AND RECONNECT TO EXIST SERVICE CONNECT TO EXIST MAIN W/TAPPING TEE & VALVES PER COR STD PLAN 300.1 REPLACE EXISTING WATER LATERAL AND METER PER COR STD PLAN 320.1 AND RECONNECT TO EXIST SERVICE EXIST WATER TO BE ABANDONED AND/OR REMOVED, SEE SHT D-26 5 1 TYP 13 17 17 M W-42 WATER SERVICE TABLE SERVICE NO.ADDRESS SIZE APPROX STATION AT MAIN FIELD VERIFIED STATION AT MAIN IRRIGATION 1.5"L7+63, 12' RT L7+61, 29' RT 235 MILL AVE S 1"L7+60, 12' RT L7+64, 28' RT 211 MILL AVE S 1"L6+65, 11' LT L6+67, 23' RT 1 2 3 13 20 20 3 1 2 5 7372CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 15 211 ± 375 LF OF 12" CL 52 REST JOINT DI WATER MAIN WITH POLYWRAP 37 CONNECT TO EXIST 12" W 37 RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHOUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••3 1 31 29 30 303132NO PARK ING PARKING F I R E L A N EFIRE LANECRPL#1 66" STLCRPL#2 51.5" STLCRPL#3 66" STL••••••••••••••••••••••8" C900 SSSTA Q0+31, 17' LT 1-12"x8" RDCR. RJxRJ 1-8" SOLID SLV, RJ STA Q0+44, 16' LT 1-12"x6" TEE, RJxFL 1-6" GV, FLxRJ 1-FH, 25' LT 1-TB 1-5'x5' CONC PAD STA Q1+05, 12' LT 1-12" CROSS, FLG 4-12" GV, FLGxRJ STA Q1+25, 10' LT 1-12"x8" RDCR, RJxRJ 1-8" SOLID SLV, RJ STA Q1+00 STA A4+12 STA Q1+20 STA A4+14 STA Q0+96, 12' LT 1-12" 45° BEND, RJ 1-TB STA Q0+92, 13' LT 1-12" 45° BEND, RJ 1-TB STA Q0+55, 15' LT 1-12" 45° BEND, RJ 1-TB STA Q0+51, 15' LT 1-12" 45° BEND, RJ 1-TB A4+00Q0+00 Q1+00 Q2+0012"DI W 12"DI W12"DI W15 20 25 30 35 40 15 20 25 30 35 40 Q0+00 Q0+20 Q0+40 Q0+60 Q0+80 Q1+00 Q1+20 Q1+40 Q1+60 Q1+80 Q2+00PROP 12"WIE=25.3EXIST TEXIST GEXIST UGP (2)EXIST TEXIST 8"SS (TBA)IE=25.8EXIST 8"SDIE=25.0EXIST TEXIST UGPPROP FH12"DI W EXIST GR @ ROW CLPROP 8"SSIE=23.7CONNECT TOEXIST 8"WCONNECT TOEXIST 8"WEXIST 8"W (TBA)EXIST 8"W EXIST 8"W STA Q0+59 1-12" 45° BEND, RJ IE=25.2 STA Q0+61 1-12" 45° BEND, RJ IE=23.2 STA Q0+92 1-12" 45° BEND, RJ IE=23.1 STA Q0+96 1-12" 45° BEND, RJ IE=25.112" MINSTA Q0+51 IE=25.0 STA Q0+55 IE=21.5 IE=21.5 IE=25.3 18-2251 W-29 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET LAKE AVE S WATER PLAN & PROFILE STA Q0+00 TO STA Q2+00 JAM BAW TTT 87NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-W-R.dwg W-29 11/10/2023 10:14 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE S 2ND STLAKE AVE S 15 B W-40 C W-40 1 15 1 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 FIRE HYDRANT ASSEMBLY PER COR STD PLAN 310.1, CLOSE EXIST HYDRANT VALVE, REMOVE HYDRANT, VALVE COVER, & VALVE BOX, SALVAGE TO COR OR DISPOSE AS DIRECTED BY CITY ENGINEER TEMPORARY WATER SERVICE WITH END CAP AND THRUST RESTRAINT, SEE SHT D-29 SEE SHT W-1 FOR PIPE CONTINUATION EXIST WATER TO BE ABANDONED AND/OR REMOVED, SEE SHT D-29 CONCRETE DEADMAN BLOCKING PER DETAIL ON W-44. TO BE INSTALLED PRIOR TO FINAL CONNECTION CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' FOR CONTINUATION SEE SHEET W-1 FOR CONTINUATION SEE SHEET W-1 27 33 27 33 100 ± 90 LF OF 12" CL 52 REST JOINT DI WATER MAIN WITH POLYWRAP 37 37 SEE W-1SEE W-1CONNECT TO EXIST 8" W CONNECT TO EXIST 8" W 9912'3'144" FROM NIPPLE TO 12"-8" REDUCER. 672" OF ALL THREAD 32" TO TOP OF 8". 4' TO TOP OF 12" RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHOUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS CONC MON IN CASE REESTABLISHED PER DNR PERMIT 7373 - 18"T X 6"W 9999 •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••33333433NO PARKING FIRE LANE34 FO DUCT8" SDR 35 SS8"PP S D12"C900 SDSTA S0+66, 0' RT 1-8"x6" RDCR, RJ 1-6" 45° BEND, RJ 1-6" SOLID SLV, RJ 1-TB STA S1+00, 0' LT = STA A11+48, 11' LT 1-12" TEE, FLG 3-12" GV, FLGxRJ 1-TB 8"DI W12"DI WA11+00A12+00STA S0+94 1-12"x8" RDCR 2-8" 45° VERT BEND 20 25 30 35 40 20 25 30 35 40 S0+20 S0+40 S0+60 S0+80 S1+00S1+00EXIST 8"SS (TBA)IE=25.8EXIST T (2)EXIST TEXIST 8"SS (TBA)IE=25.8EXIST UGP3' COVEREXIST GR @ ROW CL PROP 12"WIE=27.5EXIST 6"W PROP 12"SDIE=28.012" MINCONNECT TO EXIST 6"WEXIST 6"W 3'-8"CVR18-2251 W-30 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET RENTON HIGH SCHOOL WATER PLAN & PROFILE STA S0+00 TO STA S1+00 JAM BAW TTT 88NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-W-R.dwg W-30 11/10/2023 10:14 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILE FOR CONTINUATION SEE SHEET W-3 S 2ND STFOR CONTINUATION SEE SHEET W-3CRPL#3 66" STL8"DI W 2 N W-43 APPROX LOCATION OF EXIST 6"W 4425 25 2 SEE SHT G-6 FOR STATION CL NORTHING AND EASTINGS PROPOSED WATER MAY HAVE A CONFLICT WITH EXIST UTILITY TO BE ABANDONED, CONTRACTOR SHALL TAKE APPROPRIATE MEASURE TO INSTALL THE WATER UTILITY SUCH THAT FUNCTIONALITY OF THE EXIST UTILITY IS MAINTAINED UNTIL SUCH TIME AS IT IS ABANDONED SEE SHT W-3 FOR PIPE CONTINUATION EXIST WATER TO BE ABANDONED AND/OR REMOVED, SEE SHT D-3 CONCRETE DEADMAN BLOCKING PER DETAIL ON W-44. TO BE INSTALL PRIOR TO FINAL CONNECTION CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' HIGH SCHOOL ACCESS ROAD 32 32 321 ± 35 LF OF 8" CL 52 REST JOINT DI WATER MAIN WITH POLYWRAP 37 CONNECT TO EXIST 6" W 37 CONTRACTOR TO ROTATE 45° BEND AS NEEDED TO MAKE CONNECTION 12" 99 PROVIDE TEMPORARY SUPPORT AND PROTECT EXIST FO DUCT DURING CONSTRUCTION RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHOUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS 99 12"7'-6"92" OF 8" DI 36" TO TOP OF PIPE 1-12"x8" 99 STA A11+42, 6' LT S0+65 STA S0+90 DUCT BANK FOUND APPROX 4.5' DEEP. 8" W RUN ABOVE W/ FOAM PAD, SEE PHOTO •••••••••••••••••••••••••••••••••••••••••••••••••••••••3636363651.5"24" C900 SS12"DI SD12" PP SD6" SD8"DI S D12" DI SDSTA R0+94, 1' RT 1-12"x12" TEE, FLG (CUT-IN) 2-SOLID SLV, RJ 3-12" GV, FLGxRJ 1-TB STA R1+92, 16' LT 1-6" 90° BEND, RJ ROTATED UP 1-6" SOLID SLV, RJ 1-TB IE=34.3 STA R1+00, 0' LT STA R1+92, 2' RT 1-12" PLUG, RJ 1-4" GV, FLGxRJ 1-12"x6" TEE, RJxFLG 2-TB STA R1+79, 2' RT 1-12"x6" TEE, RJxFLG 6 GV, FLGxRJ 1-FIRE HYDRANT (20' LT) R0+83 R1+00 R2+00R2+00 STA R1+92, 6' LT 2-6" 45° VERT BEND 20 25 30 35 40 45 20 25 30 35 40 45 R0+80 R1+00 R1+20 R1+40 R1+60 R1+80 R2+00 R2+20EXIST TEXIST UGP12"DI W EXIST GR @ ROW CL 4' MINCOVERPROP 8"SDIE=34.1PROP 12"SDIE=33.4EXIST GEXIST 6"WPROP FHCONNECT TOEXIST 6"WCONNECT TOEXIST 12"WPROP 24"SSIE=14.718-2251 W-31 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET SMITHERS AVE S WATER PLAN & PROFILE STA R0+00 TO STA R1+00 SEO BAW TTT 89NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-W-R.dwg W-31 11/10/2023 10:14 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=20' HORIZ, 1"=5' VERT PROFILES 3RD ST1 TYP 1 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 CONNECT TO EXIST MAIN WITH CUT-IN TEE & VALVE PER COR STD PLAN 300.2 FH ASSY PER COR STD PLAN 310.1, CLOSE EXIST HYDRANT VALVE, REMOVE HYDRANT, VALVE COVER, & VALVE BOX, SALVAGE TO COR OR DISPOSE AS DIRECTED BY CITY ENGINEER PROVIDE DENSE FOAM CUSHION AT ALL UTILITY CROSSINGS WHERE WATERMAIN CROSSES WITHIN 6" ABOVE/BELOW ANOTHER UTILITY EXIST WATER TO BE ABANDONED AND/OR REMOVED, SEE SHT D-31 REPLACE SURVEY MONUMENT PER CITY STD DETAIL H031 AS REQUIRED FOR CONSTRUCTION 15 19 SMITHERS AVE S 10 J W-43 10 47454648CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 601 ± 95 LF OF 12" CL 52 REST JOINT DI WATER MAIN WITH POLYWRAP 37 37 J W-43 CONNECT TO EXIST 6" W 38 38 CONC MON IN CASE REESTABLISHED PER DNR PERMIT 7373 - 18"T X 6"W 1-4" 90° BEND 1-4" SOLID SLV 4" RECORD DRAWINGS SHOW CONTRACTOR SURVEYED STRUCTURE LOCATIONS AND ELEVATIONS. THE ORIGINAL DESIGN LOCATIONS AND ELEVATIONS ARE INDICATED WITH STRIKETHOUGH TEXT. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL DETAILS 7' NIPPLE TO SLEEVE 5' TO TOP OF PIPE STA R1+88 1-6" GV 1-12"x4" TEE STA R1+88 4"W4"W NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-W-DET 40-44-R.dwg W-40 11/10/2023 10:22 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 FUTURE 12" DI BY OTHERS 12" DI W6" DI W12" DI W8" CI WCRPL#3 66" STL W 8" CI W12" DI WSCALE: NTS CONNECTION DETAIL A W-1 B W-29 C W-29 D W-3 CONNECT TO EXIST 8" (BY CITY FORCES) 1-12"x8" RDCR, RJxRJ 1-8" SOLID SLV, RJ 1-8" PLUG, RJ W/2" TAP & 2" BLOW-OFF 1-TEMP TB FUTURE 12" DI BY OTHERS 12" DI W6" DI W12" DI W8" CI WCRPL#3 66" STL W 8" CI W12" DI WEXIST FH TO BE REMOVED AND REPLACE WITH NEW FH AT FINAL CONNECTION TO EXIST 8" CI W VERTICAL CROSS (MJxFL) FOR POLYPIGGING 1-BLIND FLANGE ON TOP W/ 2" TAPS & 2" PLUG 1-BLIND FLANGE ON BOTTOM 1-PLUG (MJ) W/2" TAP & 2" BLOW-OFF 1-TEMP TB CUT & CAP 12" DI W 8"DI WVERTICAL CROSS (MJxFL) FOR POLYPIGGING 1-BLIND FLANGE ON TOP W/ 2" TAPS & 2" PLUG 1-BLIND FLANGE ON BOTTOM 1-PLUG (MJ) W/2" TAP & 2" BLOW-OFF 1-TB INSTALL 2" PLUG ON TOP OF BLIND FLANGE AFTER REMOVAL OF POLYPIG BASED ON STD 300.6 BASED ON STD 300.6 & 300.5 8"DI WBASED ON STD 300.6 & 300.5BASED ON STD 300.6 & 300.5SCALE: NTS CONNECTION DETAIL SCALE: NTS CONNECTION DETAIL SCALE: NTS CONNECTION DETAIL REMOVE VALVES (3) 12" DI W12" DI W 12" DI W12" DI W12" DI WLAKE AVE SS 2ND ST S 2ND ST S 2ND ST S 2ND ST S 2ND ST WHITWORTHAVE SLAKE AVE S12" DI W 8"CI W12" DI W12" DI W12" DI W S 2ND ST WHITWORTHAVE S12" DI W12" DI W S 2ND ST NEW SERVICE AND VALVE TO BE INSTALLED ON EXISTING 12"DI W, SEE SHT W-3 1-12" PLUG, RJ W/2" TAP & 2" BLOW-OFF 1-TEMP TB 1-8" PLUG, RJ W/2" TAP & 2" BLOW-OFF 1-TEMP TB 1-12" PLUG, RJ W/2" TAP & 2" BLOW-OFF 1-TEMP TB 2" TEMP W1-12" PLUG, RJ W/2" TAP & 2" BLOW-OFF 1-TEMP TB CONNECT TO EXIST 8" (BY CITY FORCES) 1-12"x8" RDCR, RJxRJ 1-8" SOLID SLV, RJ 18-2251 W-40 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET WATER CONNECTION DETAILS - 1 JAM BAW TTT 90 CONNECT TO EXIST 12" (BY CITY FORCES) 1-12" INSULATED SOLID SLV, RJ CRPL#3 66" STL W CRPL#3 66" STL W CRPL#2 51.5" STL W CONCRETE DEADMAN BLOCKING PER DETAIL ON W-44 2-6" 45° BEND, RJ 15'-6"11'-10"3'11'-10"12'-7"12'-6"TEMP WATER SERVICE 30'-4" STA A0+96, 5' RT STA A4+24, 4' RT STA Q1+05, 12' LT STA Q0+44, 16' LT STA A12+78, 39' RT STA G0+69, 9' RT NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-W-DET 40-44-R.dwg W-41 11/10/2023 10:22 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 E W-19 G W-16 H W-20 12"DI W 12"DI W 8"CI W12"DI W 12"DI W 12"DI W12"DI WCONNECT TO PROP 12" (BY CITY FORCES) 2-12" SOLID SLV, RJ 1-22.5" VERT BEND, RJ 1-TB12" DI W12"DI W12"DI W12"DI W CONNECT TO EXIST 4" (BY CITY FORCES) 1-12" SOLID SLV, RJ VERTICAL CROSS (MJxFL) FOR POLYPIGGING 1-BLIND FLANGE ON TOP W/ 2" TAPS & 2" PLUG 1-BLIND FLANGE ON BOTTOM 1-PLUG (MJ) W/2" TAP & 2" BLOW-OFF 1-TEMP TB 1-12" PLUG, RJ W/2" TAP & 2" BLOW-OFF 1-TEMP TB VERTICAL CROSS (MJxFL) FOR POLYPIGGING 1-BLIND FLANGE ON TOP W/ 2" TAPS & 2" PLUG 1-BLIND FLANGE ON BOTTOM 1-PLUG (MJ) W/2" TAP & 2" BLOW-OFF 1-TEMP TB REMOVE VALVE BASED ON STD 300.6 & 300.1 CUT & CAP 18-2251 W-41 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET WATER CONNECTION DETAILS - 2 JAM BAW TTT 914"CI WSCALE: NTS CONNECTION DETAIL 4"DI WBASED ON STD 300.5SCALE: NTS CONNECTION DETAIL SCALE: NTS CONNECTION DETAIL BASED ON STD 300.512" DI WREMOVE VALVES (2) CUT & CAP 12" DI W12"DI W12"DI WWHITWORTH AVE SWHITWORTH AVE SCONNECT TO EXIST 12" (BY CITY FORCES) 1-12"x12" TAPPING TEE, FLG 1-12" TAPPING GV, FLGx RJ 1-12" SPL, LTF 1-12" 90° BEND, RJxRJ 2-TB 12"DI W1-12" PLUG, RJ W/2" TAP & 2" BLOW-OFF 1-TEMP TB W W12" DI WS 3RD STSHATTUCK AVE SS 3RD ST SHATTUCK AVE SS 3RD ST 12"DI W 12" DI W12"DI W12"DI W 4"CI WS 3RD ST WHITWORTH AVE S4"DI W4" DI W 1-12" BLIND FLANGE 1-TB CUT IN: (BY CITY FORCES) 1-12" TEE, RJxFLG 1-GV, RJxFLG 2-12" SOLID SLV, RJ 1-TB 1-4" PLUG, RJ W/2" TAP & 2" BLOW-OFF 1-TEMP TB 2-8" BLIND FLANGE 2-TB CONNECT TO EXIST 12" (BY CITY FORCES) 1-12" INSULATED SOLID SLV, RJ CUT IN: (BY CITY FORCES) 1-12" TEE, FLGxRJ 2-12" GV, RJ 2-12" SOLID SLV, RJ 1-TB 1-TEMP TB CUT IN: (BY CITY FORCES) 1-GV, RJxFLG 2-12" SOLID SLV, RJ 12" DI W12"DI W12"DI W 4" DI W 1-12" PLUG, RJ W/2" TAP & 2" BLOW-OFF 1-TEMP TB CONNECT TO EXIST 12" (BY CITY FORCES) 1-12" SOLID SLV, RJ 2'-4"4'-4" 11'-8" 11'-9"6'-4"14'-8"12'46'-10"6" STA G2+59, 8' RT STA F6+44, 13' LT STA G5+45, 6' LT 12"DI WL1+0012"DI WNO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-W-DET 40-44-R.dwg W-42 11/10/2023 10:22 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 K W-25 L W-25 M W-26 VERTICAL CROSS (MJxFL) FOR POLYPIGGING 1-BLIND FLANGE ON TOP W/ 2" TAPS & 2" PLUG 1-BLIND FLANGE ON BOTTOM 1-PLUG (MJ) W/2" TAP & 2" BLOW-OFF 1-TEMP TB 12"DI W12" DI W12" DI W 24"D I W 24"DI W 24"DI W 24"DI W CUT AND CAP, SEE DEMOLITION PLANS FOR CUT AND CAP LOCATION AT MILL AVE S AND HOUSER W S8"DI WCONNECT TO EXIST 24" (BY CITY FORCES) 1-24"x12" TAPPING TEE, FLG 1-TAPPING GV, FLGxRJ 1-TB 18-2251 W-42 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET WATER CONNECTION DETAILS - 3 SEO BAW TTT 92 SCALE: NTS CONNECTION DETAIL 12"DI W SCALE: NTS CONNECTION DETAIL SCALE: NTS CONNECTION DETAIL MILL AVE SHOU S E R W A Y12"DI W12"DI WMILL AVE SBRO N S O N W A Y S BRO N S O N W AY S MILL AVE S8"DI W8"W CI12"DI W12" DI W12" DI W 8"DI W12"DI W MILL AVE SMILL AVE S1-12" CAP, RJ 1-2" TEMP BLOW-OFF 1-TB CONNECT TO PROP 12" GV (BY CITY FORCES) 2-12" INSULATING SLV, RJ 1-8" BLIND FLANGE 1-TB S 2ND ST S 2ND ST CUT & CAP REMOVE VALVE CUT IN: (BY CITY FORCES) 12"x12" CROSS, RJxFL 2-12" GV, RJxFL 2-12" INSULATING SLV, RJ MILL AVE SHOU S E R W A Y 12" DI WVERTICAL CROSS (MJxFL) FOR POLYPIGGING 1-BLIND FLANGE ON TOP W/ 2" TAPS & 2" PLUG 1-BLIND FLANGE ON BOTTOM 1-PLUG (MJ) W/2" TAP & 2" BLOW-OFF 1-TEMP TB STA L1+11, 24' RT CONNECT TO EXIST 8" (BY CITY FORCES) 1-12"X8" TEE, RJxFL (ROLLED DOWN) 1-8" 45° BEND, RJ 1-8" 90° BEND, RJ 1-8" SOLID SLV, RJ 1-12" PLUG, RJ 1-TB 1-DEADMAN 8"DI W8"DI WVERTICAL CROSS (MJxFL) FOR POLYPIGGING 1-BLIND FLANGE ON TOP W/ 2" TAPS & 2" PLUG 1-BLIND FLANGE ON BOTTOM 1-PLUG (MJ) W/2" TAP & 2" BLOW-OFF 1-TEMP TB 1-12" PLUG, RJ 1-TEMP TB CONNECT TO PROP 12" (BY CITY FORCES) 1-12" SOLID SLV, RJ 1-12" 45° BEND, RJ 1-TBCRPL#3 66 " STL WCRPL#3 66 " ST L W 4 5 ' - 3 " 1 1 "65'-2"34'-4"14'- 8"15'-7"10'24'-2"STA L8+47, 17' LT STA L3+98, 11' LT FO DUCT FO DUCT 4" DI W 12"DI W 12" DI W4" DI W NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-W-DET 40-44-R.dwg W-43 11/10/2023 10:22 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 SCALE: NTS CONNECTION DETAIL SCALE: NTS CONNECTION DETAIL J W-31 CUT & CAP 8"CI W 18-2251 W-43 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET WATER CONNECTION DETAILS - 4 JAM BAW TTT 93 N W-30 4"DI WREMOVE 8" VALVE 12"DI W 8"CI W 6"DI W 12" DI W 12" DI W 12" DI W 12" DI W 6"DI W6"DI W 6"DI W6"DI W8" DI W6"DI W S 2ND ST S 2ND ST REMOVE VALVE 6" CAP CONNECT TO EXIST 6" (BY CITY FORCES) 1-12"x6" RDCR, RJxRJ 1-6" 45° BEND, RJxRJ 1-6" SOLID SLV, RJ 1-TB S 3RD ST SMITHERS AVE SCUT IN (BY CITY FORCES) 1-12" TEE, FLGxFLG 3-12" GV, FLGxRJ 2-12" SOLID SLV, RJ 1-TB 1-8" BLIND FLANGE 1-TB VERTICAL CROSS (MJxFL) FOR POLYPIGGING 1-BLIND FLANGE ON TOP W/ 2" TAPS & 2" PLUG 1-BLIND FLANGE ON BOTTOM 1-PLUG (MJ) W/2" TAP & 2" BLOW-OFF 1-TEMP TB 1-6" PLUG, RJ W/2" TAP & 2" BLOW-OFF 1-TEMP TB 1-4" PLUG, RJ W/2" TAP & 2" BLOW-OFF 1-TEMP TB CUT & CAP 12"DI W 12" DI W4"DI W12"DI W S 3RD ST SMITHERS AVE SCUT & CAP CONNECT TO EXIST 4"W (BY CITY FORCES) 1-4" SOLID SLV, RJ 1-12"x8" RDCR 2-8" 45° VERT BEND 12"7'-8"7' 21'-10" 7'-4"6' 2-6" 45° VERT BEND, RJ 6" STA A11+48, 10' LT STA R0+94, 1' RT NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-W-DET 40-44-R.dwg W-44 11/10/2023 10:22 AM ELI.JEFFERSON 24.1s (LMS Tech)SHEET 120 1 18-2251 W-44 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT JANUARY 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET POLYPIG PLAN AND TEMPORARY THRUST BLOCKING JAM BAW TTT 94 RECOMMENDED POLYPIGGING AND DISINFECTION PLAN START CONNECTION DETAIL END CONNECTION DETAIL A W-40 N W-43 D W-40 L W-42 D W-40 G W-41 E W-41 M W-42 A W-1 N W-30 D W-3 L W-25 D W-3 G W-16 E W-19 M W-26 3,600 7,200 10,800 14,400 18,000 21,600 4 1 ----- 6 5 2 ---- 8 10 8 5 3 -- 12 -23 20 18 15 13PIPE SIZE (IN)TOTAL WEIGHT OF ECOLOGY BLOCKS (LBS) TOTAL SF OF BEARING SURFACE NEEDED FOR TEMPORARY THRUST RESTRAINT USING ECOLOGY BLOCKS 1.CONTRACTOR TO CONFIRM UNCONFINED COMPRESSIVE STRENGTH OF SOIL IS AT LEAST 500 PSF. 2. TEMPORARY THRUST RESTRAINT UTILIZING ECOLOGY BLOCKS BASED ON TOTAL SYSTEM PRESSURE AND WATER HAMMER PRESSURE OF NO GREATER THAN 120 PSI. THIS TABLE SHOULD NOT BE USED FOR NEW MAIN WITH TEST PRESSURES HIGHER THAN 120 PSI. 3. SHIMS AND/OR GROUT SHALL BE PLACED AS NECESSARY TO FILL VOIDS BETWEEN RESTRAINED JOINT CAP, ECOLOGY BLOCKS, AND UNDISTURBED SOIL. NOTES: 1.BEARING SURFACE 2.TYPICAL ECOLOGY BLOCK (2x2x6) 3.TEMPORARY RESTRAINT JOINT CAP 4.EXISTING WATER MAIN TO REMAIN IN SERVICE 5.SHIMS TO BE PLACED BETWEEN CAP AND ECOLOGY BLOCK AS NEEDED 6.GROUT TO BE PLACED BETWEEN ECOLOGY BLOCK AND UNDISTURBED EARTH AS NEEDED TO PREVENT SLIDING OF THE ECOLOGY BLOC 7.TYPICAL TRENCH 8.PROPOSED WATER MAIN 9.THRUST BLOCK TO FOLLOW STD 330.2 10.2" TAP AND TEMP WATER SERVICE 43 5 6 7 1 2 8 9 7' MIN 10 K W-42 L W-42 K W-25 L W-26 7 NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-CP-R.dwg CP-1 4/26/2023 10:35 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-CP-R.dwg CP-1 4/26/2023 10:35 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 CONSTRUCTION NOTES: 1'-6" SQUARE CONCRETE SLAB, 6" THICK 1'-6" 1'-0" 18-2251 CP-1 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET CATHODIC PROTECTION - 1 95 JJM TTT BAW NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-CP-R.dwg CP-2 4/26/2023 10:35 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-CP-R.dwg CP-2 4/26/2023 10:35 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 18-2251 CP-2 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET CATHODIC PROTECTION - 2 96 JJM TTT NOTES: 1.INSTALL MAIN CONDUIT CONTINUOUS FROM END TO END WITHOUT BREAKS AT INTERMEDIATE MANHOLES. 2.INSTALL 0.25" POLYPROPYLENE PULL ROPE THROUGH ALL CONDUIT AND CAP ENDS BEFORE BURY. CAP ENDS WITH SLIP ON FITTING BUT DO NOT SOLVENT WELD. 3.SPU WILL PROVIDE OLYMPIC FOUNDRY TYPE SM29 BOX AND LID FOR LOCATIONS IN LANDSCAPED AREAS, AND FOG-TITE J11 TYPE 2 FOR LOCATIONS IN PAVED AREAS.2'-0" MIN0'-6"JUNCTION BOX SUPPLIED BY SPU, SEE NOTE 3 PAVEMENT OR LANDSCAPE RESTORATION AS NECESSARY FINISHED GRADE OUTSIDE TRAVELED WAY UNDISTURBED NATIVE SOIL CONDUIT BACKFILL TO MATCH SEWER PIPE BACKFILL PER SECTION 7-08 2" SCH 80 PVC CONDUIT WARNING TAPE SUPPLIED BY SPU, BURY 12" ABOVE CONDUIT 0'-6"UNDISTURBED NATIVE SOIL 3'-0" MIN 1'-0" MAX MANHOLE RING, COVER AND 2-6" GRADE RINGS SUPPLIED BY SPU ASPHALT SURFACE RESTORATION, SEE SHT R-40 PROPOSED UTILITY PIPE, DEPTH VARIES BURY WOOD STAKE TO INDICATE LOCATION OF FUTURE EXCAVATION MAIN CONDUIT 2'-6"BAW 12"DI W Q0+00Q1+0012"DI W12"DI W 12"DI WN3+00N4+00A0+00 A1+00 A2+00 A3+00 A4+00 •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••3 8 3 7 3 8 3 7 3 639383637 38 353 5 3 4 36 35 34 35 34 3 3 32 31333231293030 31 3233 3 4 3738434 2 41 40 39 FIRE LANE 35 CRPL#3 66" STL CRPL#1 66" STL CRPL#2 51.5" STL CRPL#3 66" STL CRPL#1 66" STL CRPL#2 51.5" STL CRPL#1 66" STL CRPL#2 51.5" STL CRPL#3 66" STL ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• •••••••••••••••••••••••••••••••••••••••••••••••••••••••• •••• •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 12"DI W 12"DI W TS E7+00 E8+00 A5+00 A6+00 A7+00 A8+00 A9+00 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 31 31 31 31 32 32 3 3 32 32 3 2 31 32 32 32 NO PARKING FIRE LAN E NO PARKINGNO PARKING FIRE LANENO PARKING FIRE LANESTOP NO PARKINGNO PARKINGNO PARKING FIRE LANE3 2 3231 CRPL#1 66" STL •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 18-2251 R-1 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 2ND ST ROADWAY RESTORATION PLANS STA A0+00 TO STA A9+60 JJM BAW TTT 97NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-REST-R.dwg R-1 4/26/2023 10:53 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 MATCHLINE STA A4+80SEE BELOWRAINIER AVE SLAKE AVE SS 2ND ST MATCHLINE STA A4+80SEE ABOVEMATCHLINE STA A9+60SEE SHEET R-3LEGEND PERMANENT HMA PATCH PER CITY STD DETAIL 110.0, 110.1 AND DETAIL 2, SHEET R-40 CEMENT CONCRETE SIDEWALK OR DRIVEWAY SAWCUT GRIND & OVERLAY PER CITY STD DETAIL 110.0 AND 110.1 REMOVE AND REPLACE WITH 6" CSTC BASE AND 8" ASPHALT PAVEMENT R-2 3 2 2 1 2 2 2 3 3 1 2 3 43 4 33 2 2 2 2 1 2 3 1 S 2ND ST 5 5 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 CURB AND GUTTER REPLACEMENT PER CITY STD DETAIL 101, 101.1, 102 AND 103, AT EXISTING AND PROPOSED CURB TIE-INS, MATCH THE CURB FACES AND EXISTING TOP OF CURB AND FLOWLINE ELEVATIONS, ADJUST LENGTH TO MATCH NEAREST EXPANSION JOINT CEMENT CONCRETE SIDEWALK REPLACEMENT PER CITY STD DETAIL 102, ADJUST PANEL LENGTH AND WIDTH TO MATCH NEAREST FULL DEPTH EXPANSION JOINT CEMENT CONCRETE DRIVEWAY ENTRANCE REPLACEMENT WITH 6" CSTC BASE, MATCH EXISTING PER CITY STD DETAIL 104, 104.2, 104.5, 105.5 AND/OR AS DIRECTED BY THE ENGINEER, ADJUST PANEL LENGTH TO MATCH NEAREST FULL DEPTH EXPANSION JOINT CROSSWALK PER CITY STD DETAIL 127 CHANNELIZATION MARKERS AND/OR TRAFFIC ARROW PER CITY STD DETAIL 109 AND WSDOT STD PLANS M-3.40-04 AND M-24.40-02 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 5 144 100 400200 2 3 2 9 9 9 9 9 9 9 TYP TYP 12"DI W12"DI W12"DI W 12"DI WG0+0012"DI W TS TS TS TS TS 8"DI SD 8" D I S D8"PP SD 12"C900 SD 12"DI S D 15"PP SD 8"DI SD 8" D I S D STA A13+15, 4.3' LT 1-SDMH #5.5 12"PP SD 12"DI SDSTA A12+98, 47.1' RT 1-MH (224)G0+00A10+00 A11+00 A12+00 A13+00 A14+00 •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••32 33 33 33 34 33 34 34 33 34 33 3333 32 NO PARKING FIRE LANE34 FO DUCT FO DUCT H0+008"C900 SD 8"DI SD8"DI SD12"PP SD 8"DI SD8"C900 SD12"C900 SDH0+00A14+00 A15+00 A16+00 A17+00 A18+00 •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••34 33 3 4 34 34 3535 35 35 3534 34 333333 •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••FO DUCT NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-REST-R.dwg R-3 4/26/2023 10:53 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 S 2ND ST MATCHLINE STA A9+60SEE SHEET R-2MATCHLINE STA A14+00SEE BELOWWHITWORTH AVE S SHATTUCK AVE S FOR CONTINUATION SEE SHEET R-19 FOR CONTINUATION SEE SHEET R-15 S 2ND ST MATCHLINE STA A14+00SEE ABOVEMORRIS AVE S FOR CONTINUATON SEE SHEET R-21 R-4 1 4 2 3 2 1 2 3 18-2251 R-3 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 2ND ST ROADWAY RESTORATION PLANS STA A9+60 TO STA A19+20 JJM BAW TTT 98 LEGEND PERMANENT HMA PATCH PER CITY STD DETAIL 110.0, 110.1 AND DETAIL 2, SHEET R-40 CEMENT CONCRETE SIDEWALK OR DRIVEWAY SAWCUT GRIND & OVERLAY PER CITY STD DETAIL 110.0 AND 110.1 REMOVE AND REPLACE WITH 6" CSTC BASE AND 8" ASPHALT PAVEMENT 1 2 3 4 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 CURB AND GUTTER REPLACEMENT PER CITY STD DETAIL 101, 101.1, 102 AND 103, AT EXISTING AND PROPOSED CURB TIE-INS, MATCH THE CURB FACES AND EXISTING TOP OF CURB AND FLOWLINE ELEVATIONS, ADJUST LENGTH TO MATCH NEAREST EXPANSION JOINT CEMENT CONCRETE SIDEWALK REPLACEMENT PER CITY STD DETAIL 102, ADJUST PANEL LENGTH AND WIDTH TO MATCH NEAREST FULL DEPTH EXPANSION JOINT CEMENT CONCRETE DRIVEWAY ENTRANCE REPLACEMENT WITH 6" CSTC BASE, MATCH EXISTING PER CITY STD DETAIL 104, 104.2, 104.5, 105.5 AND/OR AS DIRECTED BY THE ENGINEER, ADJUST PANEL LENGTH TO MATCH NEAREST FULL DEPTH EXPANSION JOINT CROSSWALK PER CITY STD DETAIL 127 STOP BAR PER CITY STD DETAIL 128 CHANNELIZATION MARKERS AND/OR TRAFFIC ARROW PER CITY STD DETAIL 109 AND WSDOT STD PLANS M-3.40-04 AND M-24.40-02 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 5 6 5 6 2 2 5 2 3 2 3 2 3 2 3 2 23 2 3 5 400 400 305 321 419 419 507 511 513 400 2 3 2 3 9 9 9 TYP 9 TYP J0+00J1+00A23+40A20+00 A21+00 A22+00 A23+00 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••37 37 37373737 37 38 3839 39 37 38 373937••••••••••••••••••••••C0+00 C1+00 C2+00 C3+00 C4+00B2+00B3+00B3+20E0+0 0 E1+0 0 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• •••••••••••••••••••••••••••••••• 33 32 34 33 32 31 30 323131••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••18-2251 R-5 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 2ND ST AND S 3RD ST ROADWAY RESTORATION PLANS STA A19+20 TO STA A23+40 & STA C0+00 TO STA C4+80 JJM BAW TTT 99NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-REST-R.dwg R-5 4/26/2023 10:53 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 S 2ND STLOGAN AVE SBURNETTE AVE SS 3RD ST MATCHLINE STA C4+80SEE SHEET R-7RAINIERAVE SSW SUNSET BLV D 165 LF 8" CIPP SSR-6 1 1 MATCHLINE STA A19+20SEE SHEET R-4LEGEND PERMANENT HMA PATCH PER CITY STD DETAIL 110.0, 110.1 AND DETAIL 2, SHEET R-40 CEMENT CONCRETE SIDEWALK OR DRIVEWAY SAWCUT GRIND & OVERLAY PER CITY STD DETAIL 110.0 AND 110.1 REMOVE AND REPLACE WITH 6" CSTC BASE AND 8" ASPHALT PAVEMENT 1 5 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 CROSSWALK PER CITY STD DETAIL 127 CHANNELIZATION MARKERS AND/OR TRAFFIC ARROW PER CITY STD DETAIL 109 AND WSDOT STD PLANS M-3.40-04 AND M-24.40-02 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 5 5 5 5 150 655 275 60 9 9 TYP 9 9 TYP 12"C900 SD 12"C900 SD 12"C900 SD 12"C900 SD C5+00 C6+00 C7+00 C8+00 C9+00 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••32 32 3131 32 32 32 32 32STOP F6+00F7+0012"DI W18" PP SD18" PP SD 18" PP SD 24" PP SD18" PP SD12"P P S D C10+00 C11+00 C12+00 C13+00 C14+00F6+00F7+00•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••32 31 31 3132 18-2251 R-7 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 3RD ST ROADWAY RESTORATION PLANS STA C4+80 TO STA C14+40 JJM BAW TTT 100NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-REST-R.dwg R-7 4/26/2023 10:53 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 S 3RD ST MATCHLINE STA C4+80SEE SHEET R-6MATCHLINE STA C9+60SEE BELOWFOR CONTINUATION SEE SHEET R-12 SHATTUCKAVE SS 3RD ST MATCHLINE STA C9+60SEE ABOVEMATCHLINE STA C14+40SEE SHEET R-9FOR CONTINUATION SEE SHEET R-16 R-8 1 4 2 1 REMOVE AND REPLACE CURB RAMP SEE SHT R-31 REMOVE AND REPLACE CURB RAMP SEE SHT R-32 REMOVE AND REPLACE CURB RAMP SEE SHT R-33 LEGEND PERMANENT HMA PATCH PER CITY STD DETAIL 110.0, 110.1 AND DETAIL 2, SHEET R-40 CEMENT CONCRETE SIDEWALK OR DRIVEWAY SAWCUT GRIND & OVERLAY PER CITY STD DETAIL 110.0 AND 110.1 REMOVE AND REPLACE WITH 6" CSTC BASE AND 8" ASPHALT PAVEMENT 1 2 3 4 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 CURB AND GUTTER REPLACEMENT PER CITY STD DETAIL 101, 101.1, 102 AND 103, AT EXISTING AND PROPOSED CURB TIE-INS, MATCH THE CURB FACES AND EXISTING TOP OF CURB AND FLOWLINE ELEVATIONS, ADJUST LENGTH TO MATCH NEAREST EXPANSION JOINT CEMENT CONCRETE SIDEWALK REPLACEMENT PER CITY STD DETAIL 102, ADJUST PANEL LENGTH AND WIDTH TO MATCH NEAREST FULL DEPTH EXPANSION JOINT CEMENT CONCRETE DRIVEWAY ENTRANCE REPLACEMENT WITH 6" CSTC BASE, MATCH EXISTING PER CITY STD DETAIL 104, 104.2, 104.5, 105.5 AND/OR AS DIRECTED BY THE ENGINEER, ADJUST PANEL LENGTH TO MATCH NEAREST FULL DEPTH EXPANSION JOINT CROSSWALK PER CITY STD DETAIL 127 STOP BAR PER CITY STD DETAIL 128 CHANNELIZATION MARKERS AND/OR TRAFFIC ARROW PER CITY STD DETAIL 109 AND WSDOT STD PLANS M-3.40-04 AND M-24.40-02 PARKING MARKERS TO MATCH EXISTING AS DIRECTED BY ENGINEER CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 5 6 2 4 2 3 2 3 2 3 6 5 5 2 3 250 112 112 112 300 107 111 115 125 200 200 300 309305207205201 9 10 FOR CONTINUATION SEE SHEET R-16 10 TYP 9 TYP 9 9 10 TYP 9 TYP 9 H5+00H6+0012"DI W18" PP SD 18" PP SD18" PP SD 12" C900 SD18" PP SD12" PP SD12"DI SD12"D I SD12"DI SD12"DI SD12"DI SD 12"DI SD C15+00 C16+00 C17+00 C18+00 C19+00G5+00G6+00G6+00H5+00H6+00•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••33 33 33 33 34 3433R0+83R1+00 12" PP SD 12" C900 SD12"DI SD12" PP SD12" PP SD6" SD12"DI SD8 "D I SD 12" DI SD C20+00 C21+00 C22+00 C23+00 C24+00 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••34 34 35 35 35 3636 3636 37 37WHITWORTHAVE S18-2251 R-9 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 3RD ST ROADWAY RESTORATION PLANS STA C14+40 TO STA C24+00 JJM BAW TTT 101NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-REST-R.dwg R-9 4/26/2023 10:53 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 S 3RD ST MATCHLINE STA C14+40SEE SHEET R-8MATCHLINE STA C19+20SEE BELOWMORRISAVE SFOR CONTINUATION SEE SHEET SS-20 FOR CONTINUATION SEE SHEET SS-21 MORRIS AVE SS 3RD ST MATCHLINE STA C19+20SEE ABOVEMATCHLINE STA C24+00SEE SHEET R-11LOGANAVE SSMITHERSAVE SR-10 FOR CONTINUATION SEE SHEET R-30 1 2 1 REMOVE AND REPLACE CURB RAMP SEE SHT R-35 REMOVE AND REPLACE CURB RAMP SEE SHT R-34 LEGEND PERMANENT HMA PATCH PER CITY STD DETAIL 110.0, 110.1 AND DETAIL 2, SHEET R-40 CEMENT CONCRETE SIDEWALK OR DRIVEWAY SAWCUT GRIND & OVERLAY PER CITY STD DETAIL 110.0 AND 110.1 REMOVE AND REPLACE WITH 6" CSTC BASE AND 8" ASPHALT PAVEMENT 1 2 3 4 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 CURB AND GUTTER REPLACEMENT PER CITY STD DETAIL 101, 101.1, 102 AND 103, AT EXISTING AND PROPOSED CURB TIE-INS, MATCH THE CURB FACES AND EXISTING TOP OF CURB AND FLOWLINE ELEVATIONS, ADJUST LENGTH TO MATCH NEAREST EXPANSION JOINT CEMENT CONCRETE SIDEWALK REPLACEMENT PER CITY STD DETAIL 102, ADJUST PANEL LENGTH AND WIDTH TO MATCH NEAREST FULL DEPTH EXPANSION JOINT CEMENT CONCRETE DRIVEWAY ENTRANCE REPLACEMENT WITH 6" CSTC BASE, MATCH EXISTING PER CITY STD DETS 104, 104.2, 104.5, 105.5 AND/OR AS DIRECTED BY THE ENGINEER, ADJUST PANEL LENGTH TO MATCH NEAREST FULL DEPTH EXPANSION JOINT CROSSWALK PER CITY STD DETAIL 127 STOP BAR PER CITY STD DETAIL 128 CHANNELIZATION MARKERS AND/OR TRAFFIC ARROW PER CITY STD DETAIL 109 AND WSDOT STD PLANS M-3.40-04 AND M-24.40-02 PARKING MARKERS TO MATCH EXISTING AS DIRECTED BY ENGINEER CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 2 3 2 3 2 3 5 5 2 3 23 2 2 3 2 3 2 3 5 5 5 2 3 3 316 400 410 422 315 319 321 325 401 405 413 415 423 280 504 510 505 507 509 601 613 5 6 9 10 10 TYP 9 TYP 9 TYP 10 TYP 6 4 C24+00 C25+00 C26+00 C26+15J6+00J6+80••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••38 3839 12"C900 SD12"C900 SDC5+00C6+00E 2 + 0 0 E3+00 E4+00 E5+00 •••••••••••••••••••••••••••••••••••••••••••••3232STOPBURNETT AVE S18-2251 R-11 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 3RD ST & PARKING LOT RESTORATION PLANS STA C24+00 TO STA C26+40 & STA E1+20 TO STA E5+00 JJM BAW TTT 102NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-REST-R.dwg R-11 4/26/2023 10:53 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 S 3RD ST MATCHLINE STA C24+00SEE SHEET R-10R-12 1 3 2 LEGEND PERMANENT HMA PATCH PER CITY STD DETAIL 110.0, 110.1 AND DETAIL 2, SHEET R-40 CEMENT CONCRETE SIDEWALK OR DRIVEWAY SAWCUT GRIND & OVERLAY PER CITY STD DETAIL 110.0 AND 110.1 REMOVE AND REPLACE WITH 6" CSTC BASE AND 8" ASPHALT PAVEMENT 1 2 3 7 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 CURB AND GUTTER REPLACEMENT PER CITY STD DETAIL 101, 101.1, 102 AND 103, AT EXISTING AND PROPOSED CURB TIE-INS, MATCH THE CURB FACES AND EXISTING TOP OF CURB AND FLOWLINE ELEVATIONS, ADJUST LENGTH TO MATCH NEAREST EXPANSION JOINT CEMENT CONCRETE SIDEWALK REPLACEMENT PER CITY STD DETAIL 102, ADJUST PANEL LENGTH AND WIDTH TO MATCH NEAREST FULL DEPTH EXPANSION JOINT PROTECT EXIST TREE AND/OR SHRUB OR REPLACE IN KIND, CONTRACTOR SHALL COORDINATE MEASURES TO MINIMIZE IMPACTS TO TREE WITH ENGINEER CHANNELIZATION MARKERS AND/OR TRAFFIC ARROW PER CITY STD DET 109 AND WSDOT STD PLANS M-3.40-04 AND M-24.40-02 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 9 280 712 710708704700 290 617 9 9TYP 2 7 2 7 S 3RD STMATCHLINE STA E5+00SEE SHEET R-13FOR CONTINUATION SEE SHEET R-6 250 112 300 REPLACE FENCE IN KIND 2 77 2 RESTORE PAVEMENT MARKING TO MATCH EXISTING OR AS DIRECTED BY THE ENGINEER Q2+00E5+00E6+00 E7+00 E8+00•••••••••••••••••••••••••••••32 32 31 32 NO PARKINGPARKING FIRE LANEFIRE LANE NO PARKING FIRE LAN E NO PARKINGNO PARKING FIRE LANENO PARKING FIRE LANESTOP 3 2 32 CRPL#1 66" STLCRPL#1 66" STL CRPL#2 51.5" STL CRPL#3 66" STL ••••••••••••••••••••••••••••••••••••••••••••••••••••••••TS E8+00 E9+00 E10+ 0 0 E11+ 0 0 3 3 32 32 31 32 NO PARKING FIRE LANENO PARKINGNO PARKINGNO PARKING FIRE LANE3 2 3231 32 ••••••••••••••••••••••••••••••••••••••18-2251 R-13 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET PARKING LOT ROADWAY RESTORATION PLANS STA E5+00 TO STA E11+00 JJM BAW TTT 103NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-REST-R.dwg R-13 4/26/2023 10:53 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 R-14 LEGEND PERMANENT HMA PATCH PER CITY STD DETAIL 110.0, 110.1 AND DETAIL 2, SHEET R-40 CEMENT CONCRETE SIDEWALK OR DRIVEWAY SAWCUT GRIND & OVERLAY PER CITY STD DETAIL 110.0 AND 110.1 REMOVE AND REPLACE WITH 6" CSTC BASE AND 8" ASPHALT PAVEMENT 2 CURB AND GUTTER REPLACEMENT PER CITY STD DETAIL 101, 101.1, 102 AND 103, AT EXISTING AND PROPOSED CURB TIE-INS, MATCH THE CURB FACES AND EXISTING TOP OF CURB AND FLOWLINE ELEVATIONS, ADJUST LENGTH TO MATCH NEAREST EXPANSION JOINT CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 203 S 2ND ST MATCHLINE STA E8+00SEE THIS SHEET BELOWMATCHLINE STA E5+00 SEE SHEET R-12 234 LF 12" CIPP SS 78 LF 12" CIPP SSS 2ND S T 165 LF 12" C I P P S S MATCHLINE STA E8+00THIS SHEET ABOVEFOR CONTINUATIONSEE SHEET R-15144 L F 1 2 " C I P P S S 211 2 F1+00 F2+00 F3+00 F4+00 F5+00 12"DI W12"DI W12"DI W12"DI WTSTS TSTS TSTS 18" PP SD 18" PP SD 18" PP SD12"PP SD12"PP SD12"PP SD15"PP SD8" DI SDE11+51E11+00A9+00A10+00F1+00 F2+00 F3+00 F4+00 F5+00 •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••323333323232 32 32 32 31 3 2 •••••••••••••••••••••••F6+00 F7+00 F8+00 F9+00 12"DI W 18" PP SD 24" PP SD18" PP SD24" PP SD12"PP SD12"D I S D12"DI S D 12"C900 SD12"C900 SD1 2 "C 9 0 0 SD C12+00C13+00F6+00 F7+00 F8+00 F9+00 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••313131 31 18-2251 R-15 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET SHATTUCK AVE S ROADWAY RESTORATION PLANS STA F0+80 TO STA F9+60 JJM BAW TTT 104NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-REST-R.dwg R-15 4/26/2023 10:53 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1S 2ND STMATCHLINE STA F5+60SEE BELOWSHATTUCK AVE S FOR CONTINUATION SEE SHEET R-3 FOR CONTINUATION SEE SHEET R-3 FOR CONTINUATION SEE SHEET R-14 S 3RD STSHATTUCK AVE S MATCHLINE STA F5+60SEE ABOVEFOR CONTINUATION SEE SHEET R-8 FOR CONTINUATION SEE SHEET R-10 R-16 3 2 1 32 2 3 2 3 2 3 1 MATCHLINE STA F9+60SEE SHEET R-17REMOVE AND REPLACE CURB RAMP SEE SHT R-32 REMOVE AND REPLACE CURB RAMP SEE SHT R-31 REMOVE AND REPLACE CURB RAMP SEE SHT R-33 REMOVE AND REPLACE CURB RAMP SEE SHT R-36 LEGEND PERMANENT HMA PATCH PER CITY STD DETAIL 110.0, 110.1 AND DETAIL 2, SHEET R-40 CEMENT CONCRETE SIDEWALK OR DRIVEWAY SAWCUT GRIND & OVERLAY PER CITY STD DETAIL 110.0 AND 110.1 REMOVE AND REPLACE WITH 6" CSTC BASE AND 8" ASPHALT PAVEMENT 1 2 3 5 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 CURB AND GUTTER REPLACEMENT PER CITY STD DETAIL 101, 101.1, 102 AND 103, AT EXISTING AND PROPOSED CURB TIE-INS, MATCH THE CURB FACES AND EXISTING TOP OF CURB AND FLOWLINE ELEVATIONS, ADJUST LENGTH TO MATCH NEAREST EXPANSION JOINT CEMENT CONCRETE SIDEWALK REPLACEMENT PER CITY STD DETAIL 102, ADJUST PANEL LENGTH AND WIDTH TO MATCH NEAREST FULL DEPTH EXPANSION JOINT CROSSWALK PER CITY STD DETAIL 127 STOP BAR PER CITY STD DET 128 PROTECT EXIST TREE OR REPLACE IN KIND, CONTRACTOR SHALL COORDINATE MEASURES TO MINIMIZE IMPACTS TO TREE WITH ENGINEER CHANNELIZATION MARKERS AND/OR TRAFFIC ARROW PER CITY STD DETAIL 109 AND WSDOT STD PLANS M-3.40-04 AND M-24.40-02 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 6 9 2 5 2 7 2 3 2 3 7 3 2 3 2 3 2 2 3 5 2 3 2 3 6 5 2 3 9 TYP 9 TYP 7 F15+00 F16+00 F16+80 36" PP SD36" PP SD8"DI SD36"PP SD F15+00 F16+00 F16+58 •••••••••••••••••••••••••••••••••••••••••••••••••••• 29 28 28 2 8 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• • • •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• F10+00 F11+00 F12+00 F13+00 F14+00 36" PP SD24" PP SD24" PP SD 24" PP SD 12"PP SD12"PP SD24"PP SD18"PP SD36"PP SD 12"DI SD 12"DI SD12"DI SD F10+00 F11+00 F12+00 F13+00 F14+00 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 30 30 3030 29 29 29 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 18-2251 R-17 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET SHATTUCK AVE S ROADWAY RESTORATION PLANS STA F9+60 TO STA F16+80 JJM BAW TTT 105NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-REST-R.dwg R-17 4/26/2023 10:53 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 R-18 1SHATTUCK AVE S MATCHLINE STA F14+60SEE ABOVES 4TH PLS 4TH STMATCHLINE STA F14+60SEE BELOWMATCHLINE STA F9+60SEE SHEET R-16SHATTUCK AVE S 1 REMOVE AND REPLACE CURB RAMP SEE SHT R-37 REMOVE AND REPLACE CURB RAMP SEE SHT R-38 REMOVE AND REPLACE CURB RAMP SEE SHT R-39 LEGEND PERMANENT HMA PATCH PER CITY STD DETAIL 110.0, 110.1 AND DETAIL 2, SHEET R-40 CEMENT CONCRETE SIDEWALK OR DRIVEWAY SAWCUT GRIND & OVERLAY PER CITY STD DETAIL 110.0 AND 110.1 REMOVE AND REPLACE WITH 6" CSTC BASE AND 8" ASPHALT PAVEMENT 1 2 3 4 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 CURB AND GUTTER REPLACEMENT PER CITY STD DETAIL 101, 101.1, 102 AND 103, AT EXISTING AND PROPOSED CURB TIE-INS, MATCH THE CURB FACES AND EXISTING TOP OF CURB AND FLOWLINE ELEVATIONS, ADJUST LENGTH TO MATCH NEAREST EXPANSION JOINT CEMENT CONCRETE SIDEWALK REPLACEMENT PER CITY STD DETAIL 102, ADJUST PANEL LENGTH AND WIDTH TO MATCH NEAREST FULL DEPTH EXPANSION JOINT CEMENT CONCRETE DRIVEWAY ENTRANCE REPLACEMENT WITH 6" CSTC BASE, MATCH EXISTING PER CITY STD DETAIL 104, 104.2, 104.5, 105.5 AND/OR AS DIRECTED BY THE ENGINEER, ADJUST PANEL LENGTH TO MATCH NEAREST FULL DEPTH EXPANSION JOINT CROSSWALK PER CITY STD DETAIL 127 STOP BAR PER CITY STD DETAIL 128 CHANNELIZATION MARKERS AND/OR TRAFFIC ARROW PER CITY STD DETAIL 109 AND WSDOT STD PLANS M-3.40-04 AND M-24.40-02 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 5 2 32 2 3 2 3 2 3 2 3 5 24 5 2 3 23 336 400 408 416 440 418 432 450 6 9 9 TYP 9 TYP 6 6 12"DI W 12"DI WG0+00 G1+00 G2+00 G3+0012"DIWTSTSTSTS TS TS8"DI SD12" PP SD 8"DI SD8 " D I S D12"DI SD8"DI SD 12"DI SD STA A12+98, 47.1' RT 1-MH (224)G0+00 G1+00 G2+00 G3+00 A12+00A13+00••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••333433 3333 33 33 ••••••••••••••••••••••••••••••••••••••12"DI W 18" PP SD18" PP SD12" PP SD 12" PP SD 12"D I S D 12"DI SD12"DI SDC16+00G4+00 G5+00 G6+00G6+00••••••••••••••••••••••••••33333333 33••••••18-2251 R-19 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET WHITWORTH AVE S ROADWAY RESTORATION PLANS STA G0+00 TO STA G6+00 JJM BAW TTT 106NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-REST-R.dwg R-19 4/26/2023 10:53 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 WHITWORTH AVE S MATCHLINE STA G3+20SEE BELOW2ND STFOR CONTINUATION SEE SHEET R-3 FOR CONTINUATION SEE SHEET R-3 WHITWORTH AVE SMATCHLINE STA G3+20SEE ABOVES 3RD STFOR CONTINUATION SEE SHEET R-9 FOR CONTINUATION SEE SHEET R-9 R-20 1 3 2 3 2 1 2 3 2 4 LEGEND PERMANENT HMA PATCH PER CITY STD DETAIL 110.0, 110.1 AND DETAIL 2, SHEET R-40 CEMENT CONCRETE SIDEWALK OR DRIVEWAY SAWCUT GRIND & OVERLAY PER CITY STD DETAIL 110.0 AND 110.1 REMOVE AND REPLACE WITH 6" CSTC BASE AND 8" ASPHALT PAVEMENT 1 2 3 4 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 CURB AND GUTTER REPLACEMENT PER CITY STD DETAIL 101, 101.1, 102 AND 103, AT EXISTING AND PROPOSED CURB TIE-INS, MATCH THE CURB FACES AND EXISTING TOP OF CURB AND FLOWLINE ELEVATIONS, ADJUST LENGTH TO MATCH NEAREST EXPANSION JOINT CEMENT CONCRETE SIDEWALK REPLACEMENT PER CITY STD DETAIL 102, ADJUST PANEL LENGTH AND WIDTH TO MATCH NEAREST FULL DEPTH EXPANSION JOINT CEMENT CONCRETE DRIVEWAY ENTRANCE REPLACEMENT WITH 6" CSTC BASE, MATCH EXISTING PER CITY STD DETAIL 104, 104.2, 104.5, 105.5 AND/OR AS DIRECTED BY THE ENGINEER, ADJUST PANEL LENGTH TO MATCH NEAREST FULL DEPTH EXPANSION JOINT CROSSWALK PER CITY STD DETAIL 127 CHANNELIZATION MARKERS AND/OR TRAFFIC ARROW PER CITY STD DETAIL 109 AND WSDOT STD PLANS M-3.40-04 AND M-24.40-02 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 5 2 3 5 2 3 2 2 3 2 3 2 3 5 5 220 215319 400 322 321 325 2 9 9 TYP REMOVE AND REPLACE CURB RAMP, SEE SHT R-34 H0+00 H1+00 H2+00 H3+00 8"C900 SD 8"DI SD8"DI SD 12"C900 SDH0+00 H1+00 H2+00 H3+00 A16+00••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••343 5 35343433 33 3333••••••••••••••••••••••••••••H4+00 H5+00 H6+00 H6+60 12" C900 SD 18" PP SD12" PP SD12" PP SD12" PP SD 12"D I S D12"DI SD12"DI SD12"DI SDC19+00H4+00 H5+00 H6+00 H6+60•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••3434 33 343418-2251 R-21 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET MORRIS AVE S ROADWAY RESTORATION PLANS STA H0+00 TO STA H6+00 JJM BAW TTT 107NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-REST-R.dwg R-21 4/26/2023 10:53 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 MORRIS AVE SS 2ND STMORRIS AVE S S 3RD STFOR CONTINUATION SEE SHEET R-9 FOR CONTINUATION SEE SHEET R-10 FOR CONTINUATION SEE SHEET R-4 FOR CONTINUATION SEE SHEET R-4 MATCHLINE STA H3+40SEE BELOWMATCHLINE STA H3+40SEE ABOVE3 2 1 1 3 2 LEGEND PERMANENT HMA PATCH PER CITY STD DETAIL 110.0, 110.1 AND DETAIL 2, SHEET R-40 CEMENT CONCRETE SIDEWALK OR DRIVEWAY SAWCUT GRIND & OVERLAY PER CITY STD DETAIL 110.0 AND 110.1 REMOVE AND REPLACE WITH 6" CSTC BASE AND 8" ASPHALT PAVEMENT 1 2 3 5 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 CURB AND GUTTER REPLACEMENT PER CITY STD DETAIL 101, 101.1, 102 AND 103, AT EXISTING AND PROPOSED CURB TIE-INS, MATCH THE CURB FACES AND EXISTING TOP OF CURB AND FLOWLINE ELEVATIONS, ADJUST LENGTH TO MATCH NEAREST EXPANSION JOINT CEMENT CONCRETE SIDEWALK REPLACEMENT PER CITY STD DETAIL 102, ADJUST PANEL LENGTH AND WIDTH TO MATCH NEAREST FULL DEPTH EXPANSION JOINT CROSSWALK PER CITY STD DETAIL 127 CHANNELIZATION MARKERS AND/OR TRAFFIC ARROW PER CITY STD DETAIL 109 AND WSDOT STD PLANS M-3.40-04 AND M-24.40-02 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 2 3 3 2 5 2 3 2 3 2 3 2 3 2 3 2 3 5 5 507 225 419 211 280 422 423 9 9 TYP 9 9 TYP K0+00 K1+00 K2+00 K3+00 K4+00 L4+00TSTSTS12"PP SD 24"C900 S DL4+00••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••444444 45 4545 464544 44444 646 CRPL#3 66" STLCPPL#3 66" STLCPPL#3 66" STLCPPL#3 66" STL ••••••••••••••••••••••••••••••••18-2251 R-24 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET S 2ND ST ROADWAY RESTORATION PLANS STA K0+00 TO STA K5+60 JJM BAW TTT 108NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-REST-R.dwg R-24 4/26/2023 10:53 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 S 2ND ST MILLAVE S1 5 2 FOR CONTINUATION SEE SHEET R-25MAIN AVE SLEGEND PERMANENT HMA PATCH PER CITY STD DETAIL 110.0, 110.1 AND DETAIL 2, SHEET R-40 CEMENT CONCRETE SIDEWALK OR DRIVEWAY SAWCUT GRIND & OVERLAY PER CITY STD DETAIL 110.0 AND 110.1 REMOVE AND REPLACE WITH 6" CSTC BASE AND 8" ASPHALT PAVEMENT 1 2 3 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 CURB AND GUTTER REPLACEMENT PER CITY STD DETAIL 101, 101.1, 102 AND 103, AT EXISTING AND PROPOSED CURB TIE-INS, MATCH THE CURB FACES AND EXISTING TOP OF CURB AND FLOWLINE ELEVATIONS, ADJUST LENGTH TO MATCH NEAREST EXPANSION JOINT CEMENT CONCRETE SIDEWALK REPLACEMENT PER CITY STD DETAIL 102, ADJUST PANEL LENGTH AND WIDTH TO MATCH NEAREST FULL DEPTH EXPANSION JOINT CROSSWALK PER CITY STD DETAIL 127 STOP BAR PER CITY STD DETAIL 128 CHANNELIZATION MARKERS AND/OR TRAFFIC ARROW PER CITY STD DETAIL 109 AND WSDOT STD PLANS M-3.40-04 AND M-24.40-02 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 5 6 6 1000 1010 201 9 2 3 6 5 6 3 2 3 2 9 TYP K3+00K4+00L0+00 L1+00 L2+00 L3+00 L4+00 L5+00 12"DI W 12"DI W TS TS TS12"PP SD24"C900 SDL0+00 L1+00 L2+00 L3+00 L4+00 L5+00 K3+00K4+00••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••46 454644 45 4544 4 4 45 46 4 343 CRPL#3 66" STL CPPL#3 66" STLL5+00 L6+00 L7+00 L8+00 L9+00L9+00 12"DI W 12"DI W 12"DI W 12" PP SD 12"PP SD 8"C900 SD8"C900 SD8"DI SD L5+00 L6+00 L7+00 L8+00 L9+00L9+00 ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••4 7 47 4 7 48 4 9 5 3 5 2 5 1 5 0 4 9 48 4 74747 46 46 46 46 46 45 CRPL#3 66" STLCRPL#3 66" STL CRPL#3 66" STL 18-2251 R-25 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET MILL AVE S ROADWAY RESTORATION PLANS STA L0+00 TO STA L9+00 JJM BAW TTT 109NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-REST-R.dwg R-25 4/26/2023 10:53 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 MILL AVE S S 2ND STFOR CONTINUATION SEE SHEET R-24 MATCHLINE STA L5+80SEE BELOWMILL AVE S HOUSER WAY SMATCHLINE STA L5+00SEE ABOVER-26 1 2 3 2 3 2 3 2 3 1 2 3 2 3 2 3 2 3 2 3 2 3 2 3 2 3 4 2 CONTRACTOR SHALL NOT DISTURB ANY PART OF THE BRIDGE ABUTMENT. 3 8 2 5 LEGEND PERMANENT HMA PATCH PER CITY STD DETAIL 110.0, 110.1 AND DETAIL 2, SHEET R-40 CEMENT CONCRETE SIDEWALK OR DRIVEWAY SAWCUT GRIND & OVERLAY PER CITY STD DETAIL 110.0 AND 110.1 REMOVE AND REPLACE WITH 6" CSTC BASE AND 8" ASPHALT PAVEMENT 1 2 3 4 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 CURB AND GUTTER REPLACEMENT PER CITY STD DETAIL 101, 101.1, 102 AND 103, AT EXISTING AND PROPOSED CURB TIE-INS, MATCH THE CURB FACES AND EXISTING TOP OF CURB AND FLOWLINE ELEVATIONS, ADJUST LENGTH TO MATCH NEAREST EXPANSION JOINT CEMENT CONCRETE SIDEWALK REPLACEMENT PER CITY STD DETAIL 102, ADJUST PANEL LENGTH AND WIDTH TO MATCH NEAREST FULL DEPTH EXPANSION JOINT CEMENT CONCRETE DRIVEWAY ENTRANCE REPLACEMENT WITH 6" CSTC BASE, MATCH EXISTING PER CITY STD DETAIL 104, 104.2, 104.5, 105.5 AND/OR AS DIRECTED BY THE ENGINEER, ADJUST PANEL LENGTH TO MATCH NEAREST FULL DEPTH EXPANSION JOINT CROSSWALK PER CITY STD DETAIL 127 STOP BAR PER CITY STD DETAIL 128 BRICK SIDEWALK TO BE REPLACED IN KIND, CONTRACTOR TO REUSE BRICK TO THE EXTENT POSSIBLE, IF NEW BRICK IS NEEDED, IT SHALL BE OF THE SAME SIZE AND COLOR PATTERN, SUBSURFACE LAYERS TO MATCH EXISTING AND BE SUFFICIENTLY HAND COMPACTED SUCH THAT NO SETTLING OCCURS CHANNELIZATION MARKERS AND/OR TRAFFIC ARROW PER CITY STD DETAIL 109 AND WSDOT STD PLANS M-3.40-04 AND M-24.40-02 RAILROAD CROSSING MARKING PER WSDOT STD PLAN M-11.10-03 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 5 6 8 6 5 6 5 2 3 2 3 100 1023 1010 211 9 11 9 TYP 9 TYP 9 11 9 R0+83 R1+00 R2+00R2+00 12"DI SD6" SD8"DI S D12" DI SDC22+00C23+00•••••••••••••••••••••••••••••••••••••••••••••••••••3636363636 Q0+00 Q1+00 Q2+0012"DI W 12"DI W12"DI WE6+00A4+00•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••3 1 31 29 30 303132NO PARK ING PARKING F I R E L A N EFIRE LANECRPL#1 66" STLCRPL#2 51.5" STLCRPL#3 66" STL••••••••••••••••••••••18-2251 R-29 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET LAKE AVE S & SMITHERS AVE S RESTORATION PLANS STA Q0+00 TO STA Q2+00 & STA R0+00 TO STA R2+00 JJM BAW TTT 110NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-REST-R.dwg R-29 4/26/2023 10:53 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 SMITHERS AVE SS 3RD STFOR CONTINUATION SEE SHEET R-10 R-30 FOR CONTINUATION SEE SHEET R-10 24S 2ND STLAKE AVE S FOR CONTINUATION SEE SHEET R-1 FOR CONTINUATION SEE SHEET R-1 1 1 2 3 LEGEND PERMANENT HMA PATCH PER CITY STD DETAIL 110.0, 110.1 AND DETAIL 2, SHEET R-40 CEMENT CONCRETE SIDEWALK OR DRIVEWAY SAWCUT GRIND & OVERLAY PER CITY STD DETAIL 110.0 AND 110.1 REMOVE AND REPLACE WITH 6" CSTC BASE AND 8" ASPHALT PAVEMENT 1 2 3 4 CONSTRUCTION CL EQUALS R/W CL, SEE SURVEY CONTROL PLAN, SHT G-6 CURB AND GUTTER REPLACEMENT PER CITY STD DETAIL 101, 101.1, 102 AND 103, AT EXISTING AND PROPOSED CURB TIE-INS, MATCH THE CURB FACES AND EXISTING TOP OF CURB AND FLOWLINE ELEVATIONS, ADJUST LENGTH TO MATCH NEAREST EXPANSION JOINT CEMENT CONCRETE SIDEWALK REPLACEMENT PER CITY STD DETAIL 102, ADJUST PANEL LENGTH AND WIDTH TO MATCH NEAREST FULL DEPTH EXPANSION JOINT CEMENT CONCRETE DRIVEWAY ENTRANCE REPLACEMENT WITH 6" CSTC BASE, MATCH EXISTING PER CITY STD DETAIL 104, 104.2, 104.5, 105.5 AND/OR AS DIRECTED BY THE ENGINEER, ADJUST PANEL LENGTH TO MATCH NEAREST FULL DEPTH EXPANSION JOINT CROSSWALK PER CITY STD DETAIL 127 STOP BAR PER CITY STD DETAIL 128 CHANNELIZATION MARKERS AND/OR TRAFFIC ARROW PER CITY STD DETAIL 109 AND WSDOT STD PLANS M-3.40-04 AND M-24.40-02 CONSTRUCTION NOTES: 20100 40 60 PLAN SCALE: 1"=20' 20100 40 60 PLAN SCALE: 1"=20' 5 2 3 5 601 6 9 5 9 TYP 9 TYP 6 REMOVE AND REPLACE CURB RAMP, SEE SHT R-35 ••RAD=29.74' Δ=13°41'12" L=7.1 RAD=19.62' Δ=16°11'53" L=5.5 RAD=16.83' Δ=17°21'43" L=5.1 RAD=24.88' Δ=13°24'11" L=5.8 RAD=32.82' Δ=5°01'41" L=2.9 RAD=53.63' Δ=9°25'03" L=8.8 STA C12+54, 22' LT BEGIN CURB AND GUTTER STA C12+58, 54' LT END CURB AND GUTTER •• EL=31.74 EL=31.68 EL=31.70 EL=31.69± MATCH EXIST EL=31.36± MATCH EXIST EL=30.92± MATCH EXIST EL=31.11± MATCH EXIST EL=30.95± MATCH EXIST EL=31.09± MATCH EXIST EL=31.16± MATCH EXIST TC=31.42 TC=31.36 EXIST TC=31.01 TC=31.05 TC=31.55 TC=31.52 FL=30.91 EXIST FL=30.97 FL=31.01 FL=31.05 FL=31.10 FL=31.12 EL=31.61 EL=31.56 EL=31.04 EL=31.09 EL=31.68± MATCH EXIST EL=31.06 EL=31.02 EL=31.45± MATCH EXIST TC=31.44 EXIST FL=31.01 EXIST EL=31.07 1.2%0.5%1.0%1.5% 7.5%0.5%1.5% 2 . 8% 2 . 8%7.9%8.7%1.9%0.9%0.9% 18-2251 R-31 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET CURB RAMP DETAILS - 1 ARC ARC TTT 111NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-CURB_RAMPS-R.dwg R-31 4/25/2023 9:04 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=5' SHATTUCK AVE S AND S 3RD ST - NW CORNER PLAN SCALE: 1"=5' SHATTUCK AVE S AND S 3RD ST - NW CORNER GRADING 7.8'5.0'1.8'8.4'1 1 . 6 ' 7.2' 14.4'7.1'5.5'5.1'5.8'2.9'1 3 4 4 7 9 2 8 10 11 5 5 KEY NOTES SAWCUT & REMOVE EXIST SIDEWALK CURB AND GUTTER TO NEAREST JOINT PAST MATCH LINE. CONSTRUCT PERPENDICULAR CURB RAMPS PER WSDOT STD PLAN F-40.15-03 FURNISH AND INSTALL RED DETECTABLE WARNING SURFACE PER WSDOT STD PLAN F-45.10-02 CONSTRUCT CEMENT CONC CURB PER COR STD PLANS 101 AND 103. CONSTRUCT CEMENT CONC SIDEWALK PER COR STD PLAN 102 INSTALL HMA TO MATCH EXIST PAVEMENT THICK, SEE ROADSIDE DETAIL SHT R-40 ADJUST EXIST UTILITY BOX/VAULT/MH TO FINISHED GRADE, COORDINATE WITH CITY 4 WEEKS PRIOR TO CONSTRUCTION ADJUST EXIST UTILITY BOX/VAULT/MH TO FINISHED GRADE, BY OTHERS PROTECT EXIST STREET LIGHT TO REMAIN. PROTECT EXIST CABINET PROTECT EXIST FENCE PROTECT EXIST UTILITY VAULT/BOX PROTECT EXIST PED PUSH BUTTON REFER TO SD SHT SD-8 FOR STORM IMPROVEMENTS REMOVE AND REINSTALL THERMAL PLASTIC CROSSWALK LINE PER COR STD PLAN 127 REMOVE AND REINSTALL THERMAL STOP BAR MARKING PER COR STD PLAN 128 1 2 3 4 5 6 7 8 9 10 11 13 14 19 20 21 SLOPE AS SHOWN (MAX 2.0% FINISHED SURFACE SLOPE) SLOPE AS SHOWN (MAX 8.3% FINISHED SURFACE SLOPE) TRUNCATED DOME DETECTABLE WARNING SURFACE 1.5% MAX. SLOPE LANDING IN ALL DIRECTIONS CURB RAMP LEGEND SAWCUT AND PAVEMENT PATCH LIMITS 2' MIN. FROM FACE OF CURB OR GUTTER PAN TO MEET CROSS SLOPE REQUIREMENTS (SEE TYPICAL SIDEWALK RAMP REPLACEMENT SECTION DETAIL, SHT. R40) CURB RAMP PAY LIMIT 14 1 8.1' 6 11.4'8.2'10 7 7 8.8' 19 5 19 19 10 13 20 21 19 •••••••••••••••••RAD=26.69' Δ=26°12'35" L=12.2 RAD=16.60' Δ=21°16'44" L=6.2 RAD=43.66' Δ=6°36'24" L=5.0 RAD=45.04' Δ=6°39'50" L=5.2 RAD=14.15' Δ=20°09'14" L=5.0 STA C12+58, 47' RT END CURB AND GUTTER STA C12+47, 18' RT BEGIN CURB AND GUTTER STA C12+91, 40' RT END CURB AND GUTTER •••••••••••••••••EL=30.87± MATCH EXIST EL=30.74± MATCH EXIST EL=30.71± MATCH EXIST EL=30.69± MATCH EXIST EL=31.28± MATCH EXIST EL=30.60± MATCH EXIST TC=31.32 TC=31.18 TC=30.70 TC=30.67 TC=31.13 TC=31.12 EXIST FL=30.75 FL=30.73 FL=30.69 FL=30.66 FL=30.63 FL=30.60 EXIST EL=31.24 EL=31.22 EL=31.43± MATCH EXIST TC=30.87 EXIST FL=30.80 EXIST RIM EL=30.77 EL=31.13± MATCH EXIST TC=31.46 EXIST FL=31.46 EXIST TC=31.42 FL=31.29 TC=31.30 EXIST FL=31.28 EXIST EL=31.48± MATCH EXIST EL=31.41± MATCH EXIST EL=30.81± MATCH EXIST 1.5% 1.5%0.5%7.5% 1.5% 1.3%0.1%7.9%8.4%0.4%3 . 3%0.1%1. 2% 2.0%1.5%18-2251 R-32 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET CURB RAMP DETAILS - 2 ARC ARC TTT 112NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-CURB_RAMPS-R.dwg R-32 4/25/2023 9:04 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=5' SHATTUCK AVE S AND S 3RD ST - SW CORNER PLAN SCALE: 1"=5' SHATTUCK AVE S AND S 3RD ST - SW CORNER GRADING10.1'5.0'2.4'5.0'7.3' 6.7' 11.6' 9.5'5.0'5.2'5.0'6.2' 8 1 13 1 2 12 3 5 19 KEY NOTES SAWCUT & REMOVE EXIST SIDEWALK CURB AND GUTTER TO NEAREST JOINT PAST MATCH LINE. CONSTRUCT PERPENDICULAR CURB RAMPS PER WSDOT STD PLAN F-40.15-03 FURNISH AND INSTALL RED DETECTABLE WARNING SURFACE PER WSDOT STD PLAN F-45.10-02 CONSTRUCT CEMENT CONC CURB PER COR STD PLANS 101 AND 103. CONSTRUCT CEMENT CONC SIDEWALK PER COR STD PLAN 102 INSTALL HMA TO MATCH EXIST PAVEMENT THICK, SEE ROADSIDE DETAIL SHT R-40 ADJUST EXIST UTILITY BOX/VAULT/MH TO FINISHED GRADE, BY OTHERS PROTECT EXIST PEDESTRIAN SIGNAL POLE PROTECT EXIST UTILITY VAULT/BOX PROTECT EXIST PED PUSH BUTTON REFER TO SD SHTS SD-8 FOR STORM IMPROVEMENTS 1 2 3 4 5 6 8 12 13 14 19 SLOPE AS SHOWN (MAX 2.0% FINISHED SURFACE SLOPE) SLOPE AS SHOWN (MAX 8.3% FINISHED SURFACE SLOPE) TRUNCATED DOME DETECTABLE WARNING SURFACE 1.5% MAX. SLOPE LANDING IN ALL DIRECTIONS CURB RAMP LEGEND 13 14 5 4 6 8. 0 '4. 4 ' SAWCUT AND PAVEMENT PATCH LIMITS 2' MIN. FROM FACE OF CURB OR GUTTER PAN TO MEET CROSS SLOPE REQUIREMENTS (SEE TYPICAL SIDEWALK RAMP REPLACEMENT SECTION DETAIL, SHT. R-40) CURB RAMP PAY LIMIT 144.0'3.8'8.4'19 •••••••••••••Δ=21°16'44" RAD=15.60' Δ=41°08'54" L=11.2 RAD=20.76' Δ=13°50'08" L=5.0 RAD=21.90' Δ=14°08'39" L=5.4 STA C12+94, 20' RT BEGIN CURB AND GUTTER STA C12+91, 40' RT END CURB AND GUTTER •••••••••••••EL=30.63± MATCH EXIST EL=30.76± MATCH EXIST EL=30.76± MATCH EXIST EL=30.81± MATCH EXIST EL=30.96± MATCH EXIST RIM EL=30.86 EL=31.54± MATCH EXIST EL=31.38± MATCH EXIST EL=31.46 EL=31.44± MATCH EXIST EL=31.37 TC=31.0 EXIST TC=30.70 TC=30.76 TC=31.3 EXIST FL=30.9 EXIST FL=30.76 FL=30.70 EL=30.77 EL=30.71 FL=30.6 EXIST TC=31.28 FL=30.83 EL=31.41± MATCH EXIST EL=31.03± MATCH EXIST EL=31.40± MATCH EXIST 1.6%1.3%1.5% 1.7%8.2%6.4%2.5% 7.2%1.6%0.1%1.5%1. 6% 1 . 3% 18-2251 R-33 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET CURB RAMP DETAILS - 3 ARC ARC TTT 113NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-CURB_RAMPS-R.dwg R-33 4/25/2023 9:04 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=5' SHATTUCK AVE S AND S 3RD ST - SE CORNER PLAN SCALE: 1"=5' SHATTUCK AVE S AND S 3RD ST - SE CORNER GRADING5.0'5.0'6.0'9.2' 9.3' 13.9'5.4'5 13 8 13 23 1 1 19 KEY NOTES SAWCUT & REMOVE EXIST SIDEWALK CURB AND GUTTER TO NEAREST JOINT PAST MATCH LINE. CONSTRUCT PERPENDICULAR CURB RAMPS PER WSDOT STD PLAN F-40.15-03 FURNISH AND INSTALL RED DETECTABLE WARNING SURFACE PER WSDOT STD PLAN F-45.10-02 CONSTRUCT CEMENT CONC CURB PER COR STD PLANS 101 AND 103. CONSTRUCT CEMENT CONC SIDEWALK PER COR STD PLAN 102 INSTALL HMA TO MATCH EXIST PAVEMENT THICK, SEE ROADSIDE DETAIL SHT R-40 ADJUST EXIST UTILITY BOX/VAULT/MH TO FINISHED GRADE, BY OTHERS PROTECT EXIST PEDESTRIAN SIGNAL POLE PROTECT EXIST UTILITY VAULT/BOX PROTECT EXIST PED PUSH BUTTON REFER TO SD SHT SD-8 FOR STORM IMPROVEMENTS REMOVE AND REINSTALL THERMAL PLASTIC CROSSWALK LINE PER COR STD PLAN 127 PROTECT EXIST BUILDING 1 2 3 4 5 6 8 12 13 14 19 20 22 SLOPE AS SHOWN (MAX 2.0% FINISHED SURFACE SLOPE) SLOPE AS SHOWN (MAX 8.3% FINISHED SURFACE SLOPE) TRUNCATED DOME DETECTABLE WARNING SURFACE 1.5% MAX. SLOPE LANDING IN ALL DIRECTIONS CURB RAMP LEGEND 146.3'4.9'5.0'6.0' 9. 5 ' 1 6 SAWCUT AND PAVEMENT PATCH LIMITS 2' MIN. FROM FACE OF CURB OR GUTTER PAN TO MEET CROSS SLOPE REQUIREMENTS (SEE TYPICAL SIDEWALK RAMP REPLACEMENT SECTION DETAIL, SHT. R-40) PAY LIMIT 12 20 8 2.8'.8'8 . 1 ' 22 STA C15+46, 22' LT BEGIN CURB AND GUTTER STA C15+72, 52' LT END CURB AND GUTTER STA C15+64, 22' LT BEGIN CURVE STA C15+72, 30' LT END CURVE EL=32.97± MATCH EXIST EL=32.76± MATCH EXIST EL=32.16± MATCH EXIST EL=32.29± MATCH EXIST EL=32.16± MATCH EXIST EL=32.17± MATCH EXIST EL=32.19± MATCH EXIST FL=32.8 EL=32.74 EL=32.30 EL=32.30 EL=32.22 EL=32.25 EL=32.25 TC=32.1 EXIST TC=32.29 TC=32.34 TC=32.16 TC=32.13 TC=32.7 FL=32.1 FL=32.13 FL=32.16 FL=32.34FL=32.29 FL=32.1 EXIST FL=32.82 FL=32.38 FL=32.30 TC=32.8 TC=32.83 TC=32.82 RIM EL=32.1 TC=32.83 TC=32.70 FL=32.20 EL=32.44± MATCH EXIST EL=32.40± MATCH EXIST TC=32.7 FL=32.2 EL=32.30± MATCH EXIST TC=32.64 FL=32.15 EL=32.58 1.5% 1.5%1.1%1.7% 6.0%6.3%1.5%1.5%1.4% 1.0 %5.4%6.4%2.6%9.5%3.1%4.2%11.3% 1.5%1.0%0.1%1.1%0.7%0.6%1.1% EL=33.02± MATCH EXIST TC=32.3 EXIST FL=32.2 EXIST 0.1%0.6% EL=32.77 6.0%4.9%18-2251 R-34 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET CURB RAMP DETAILS - 4 ARC ARC TTT 114NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-CURB_RAMPS-R.dwg R-34 4/25/2023 9:04 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=5' WHITWORTH AVE S AND S 3RD ST - NW CORNER PLAN SCALE: 1"=5' WHITWORTH AVE S AND S 3RD ST - NW CORNER GRADING 5.0' 1 1 11 3 19 15 4 7 9 22 16 2 5 4 KEY NOTES SAWCUT & REMOVE EXIST SIDEWALK CURB AND GUTTER TO NEAREST JOINT PAST MATCH LINE. CONSTRUCT COMBINATION CURB RAMPS PER THIS SHEET FURNISH AND INSTALL RED DETECTABLE WARNING SURFACE PER WSDOT STD PLAN F-45.10-02 CONSTRUCT CEMENT CONC CURB PER COR STD PLANS 101 AND 103. CONSTRUCT CEMENT CONC SIDEWALK PER COR STD PLAN 102 INSTALL HMA TO MATCH EXIST PAVEMENT THICK, SEE ROADSIDE DETAIL SHT R-40 REMOVE AND ABANDON EXIST STREET LIGHT JUNCTION BOX. COORDINATE WITH CITY 4 WEEKS PRIOR TO CONSTRUCTION. REMOVE EXIST LUMINAIRE POLE AND SIGNS. COORDINATE WITH CITY 4 WEEKS PRIOR TO CONSTRUCTION SALVAGE EXIST LIGHT FIXTURE AND DELIVER TO CITY MAINTENANCE FACILITY PROTECT EXIST FENCE PROTECT EXIST UTILITY VAULT/BOX PROTECT EXIST HYDRANT REMOVE EXIST STOP AND NO PARKING SIGN AND WOOD POST REFER TO SD SHT SD-9 FOR STORM IMPROVEMENTS REMOVE ABANDONED WATER METER INSTALL DECORATIVE PEDESTRIAN LUMINAIRE POLE PER COR STD PLAN 117.2, 117.3, 117.4, AND SHT R-41. LUMINARIE ARM SHALL BE ORIENTED TOWARD ROADWAY. LUMINAIRE BASE COVER SHALL BE AT LEAST 1.5 FEET CLEAR FROM FACE OF CURB. CENTER OF POLE SHALL BE LOCATED APPROX 2.5 FEET FROM FACE OF CURB. INSTALL STREET LIGHT JUNCTION-BOX PER COR STD PLAN 119 AND 120 REINSTALL EXIST SIGNS THAT WERE REMOVED FROM EXIST LUMINAIRE POLE TO NEW METAL POST PER COR STD PLAN 129 DO NOT ENTER SIGN SHALL FACE EAST. ONE WAY SIGN SHALL BE FACED NORTH. CLEARANCE FROM BOTTOM OF LOWEST SIGN TO PROPOSED GROUND LEVEL SHALL BE AT LEAST 7 FEET PER STD PLAN REINSTALL EXIST STOP AND NO PARKING SIGN THAT WERE REMOVED FROM THE EXIST WOOD POST WITH NEW METAL POST PER COR STD 129. EDGE OF SIGN SHALL BE APPROX 1.5 FEET CLEAR FROM FACE OF CURB. CLEARANCE FROM BOTTOM OF LOWEST SIGN TO PROPOSED GROUND LEVEL SHALL BE AT LEAST 7 FEET PER STD PLAN. CREATE SMOOTH TRANSITION BETWEEN CURB RAMPS AND CURB RETURN 1 2 3 4 5 6 7 9 11 13 15 16 19 22 23 24 25 26 27 SLOPE AS SHOWN (MAX 2.0% FINISHED SURFACE SLOPE) SLOPE AS SHOWN (MAX 8.3% FINISHED SURFACE SLOPE) TRUNCATED DOME DETECTABLE WARNING SURFACE 1.5% MAX. SLOPE LANDING IN ALL DIRECTIONS NEW S/W PANEL TO TRANSITION TO EXIST. S/W SLOPE AND WIDTH, MAX. 2% CROSS SLOPE AT TOP OF RAMP. TRANSITION CURB TO MATCH EXIST. CURB RAMP LEGEND 6 SAWCUT AND PAVEMENT PATCH LIMITS 2' MIN. FROM FACE OF CURB OR GUTTER PAN TO MEET CROSS SLOPE REQUIREMENTS (SEE TYPICAL SIDEWALK RAMP REPLACEMENT SECTION DETAIL, SHT. R-40) PAY LIMIT 5 133.7'7.5'5.0'7.9'5.0' 3.9'3.9'7.3'5.7'4.1'5.7'8.5'7.0' 4.0' 9.6'4.0'5.7'5.2'9.4'7.5'7.2'5.7'2.5'7.2'2.4'10.5'5.4' 5.4' 24 23 GENERAL NOTES 1. LUMINAIRE SHALL BE OUT OF SERVICE AS SHORT A TIME PERIOD AS POSSIBLE BEFORE THE NEW DECORATIVE PEDESTRIAN LUMINAIRE IS OPERATIONAL. 2. LUMINAIRE POLE RELOCATION PLAN SHALL BE SUBMITTED TO THE CITY FOR REVIEWS AND APPROVAL WITH 4 WEEKS PRIOR TO ITS RELOCATION. 3 25 26 1 11/25/20 DESIGN REVISIONS AND CLARIFICATIONSTTT 1 ENTIRE SHEET R8 . 3 ' 27 12" DI S D RAD=48.56' Δ=4°47'00" L=4.1 STA C22+56, 23' RT BEGIN CURB AND GUTTER STA C22+75, 22' RT END CURB AND GUTTER 12" DI S D EL=35.79 EL=35.83 EL=36.11 EL=36.02± MATCH EXIST EL=35.55± MATCH EXIST EL=35.63± MATCH EXIST EL=35.63± MATCH EXIST EL=35.67± MATCH EXIST EL=35.69± MATCH EXIST EL=35.61± MATCH EXIST EL=36.22± MATCH EXIST EL=36.00± MATCH EXIST EL=36.14± MATCH EXIST TC=36.0 EXIST TC=35.53 TC=35.57 TC=36.07 TC=36.1 EXIST TC=36.17TC=36.12TC=36.06 TC=36.0 EXIST FL=36.0 EXIST FL=35.85 FL=35.89 FL=36.17 FL=35.6 EXIST FL=35.57 FL=35.56 FL=35.52 FL=35.5 EXIST TC=35.51 3.1%5.5%7.5%0.8%1.5%1.5%0.8%1.5%0.3%8.5%9.5% 18-2251 R-35 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET CURB RAMP DETAILS - 5 ARC ARC TTT 115NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-CURB_RAMPS-R.dwg R-35 4/25/2023 9:04 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=5' SMITHERS AVE S AND S 3RD ST - SE CORNER PLAN SCALE: 1"=5' SMITHERS AVE S AND S 3RD ST - SE CORNER GRADING7.0'4.0'3.1'3.0'4.9'5.0'5.2'3.7'7.5'4.0'5.0'5.0'3.8'5.1' 1 4 4 1 5 2 3 12 13 4 KEY NOTES SAWCUT & REMOVE EXIST SIDEWALK CURB AND GUTTER TO NEAREST JOINT PAST MATCH LINE. CONSTRUCT PARALLEL CURB RAMP PER WSDOT STD PLAN F-40.12-03. FURNISH AND INSTALL RED DETECTABLE WARNING SURFACE PER WSDOT STD PLAN F-45.10-02 CONSTRUCT CEMENT CONC CURB PER COR STD PLANS 101 AND 103. CONSTRUCT CEMENT CONC SIDEWALK PER COR STD PLAN 102 INSTALL HMA TO MATCH EXIST PAVEMENT THICK, SEE ROADSIDE DETAIL SHT R-40 PROTECT EXIST SIGNAL POLE PROTECT EXIST UTILITY VAULT/BOX REFER TO SD SHT SD-10 FOR STORM IMPROVEMENTS REMOVE AND REINSTALL THERMAL PLASTIC CROSSWALK LINE PER COR STD PLAN 127 1 2 3 4 5 6 12 13 19 20 SLOPE AS SHOWN (MAX 2.0% FINISHED SURFACE SLOPE) SLOPE AS SHOWN (MAX 8.3% FINISHED SURFACE SLOPE) TRUNCATED DOME DETECTABLE WARNING SURFACE 1.5% MAX. SLOPE LANDING IN ALL DIRECTIONS NEW S/W PANEL TO TRANSITION TO EXIST. S/W SLOPE AND WIDTH, MAX. 2% CROSS SLOPE AT TOP OF RAMP. TRANSITION CURB TO MATCH EXIST. CURB RAMP LEGEND 19 6 SAWCUT AND PAVEMENT PATCH LIMITS 2' MIN. FROM FACE OF CURB OR GUTTER PAN TO MEET CROSS SLOPE REQUIREMENTS (SEE TYPICAL SIDEWALK RAMP REPLACEMENT SECTION DETAIL, SHT. R-40) PAY LIMIT 5 20 12"C900 SDRAD=54.72' Δ=3°57'57" L=3.8 RAD=28.34' Δ=27°49'31" L=13.8 RAD=18.60' Δ=16°25'00" L=5.3RAD=18.60' Δ=15°44'59" L=5.1 RAD=47.91' Δ=8°50'41" L=7.4 RAD=35.48' Δ=7°38'59" L=4.7 12"C900 SDTC=30.71 TC=31.14 TC=31.14 TC=30.45 TC=30.38 EXIST TC=30.35 TC=29.71 TC=29.77 TC=30.32 TC=30.23 EXIST FL=29.92 EXIST FL=29.87 FL=29.76 FL=29.71 RIM EL=29.69 FL=29.90 FL=30.02 EXIST EL=30.05± MATCH EXIST EL=30.18± MATCH EXISTEL=30.49± MATCH EXIST EL=29.93± MATCH EXIST EL=30.03± MATCH EXIST EL=29.87± MATCH EXIST EL=29.88± MATCH EXIST EL=29.78 EL=29.73 FL=30.45 FL=30.41 FL=29.87 FL=29.81 TC=30.51 EXIST FL=30.51 EXIST 5.9%6.5%1 . 5% 1. 5%1.0%1.0%1.5%1.5% 4.7%4.9%18-2251 R-36 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET CURB RAMP DETAILS - 6 ARC ARC TTT 116NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-CURB_RAMPS-R.dwg R-36 4/25/2023 9:04 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=5' SHATTUCK AVE S AND S 3RD PL - NW CORNER PLAN SCALE: 1"=5' S SHATTUCK AVE AND S 3RD PL - NW CORNER GRADING6.1'4.0'4.0'6 . 2 ' 6.0'5.6'4.7'5.3'13.8'4.8'8.9'5.0'9.5'19 31 15 2 4 4 4 17 KEY NOTES SAWCUT & REMOVE EXIST SIDEWALK CURB AND GUTTER TO NEAREST JOINT PAST MATCH LINE. CONSTRUCT PARALLEL CURB RAMP PER WSDOT STD PLAN F-40.12-03 FURNISH AND INSTALL RED DETECTABLE WARNING SURFACE PER WSDOT STD PLAN F-45.10-02 CONSTRUCT CEMENT CONC CURB PER COR STD PLANS 101 AND 103. CONSTRUCT CONC CEMENT SIDEWALK PER COR STD PLAN 102 INSTALL HMA TO MATCH EXIST PAVEMENT THICK, SEE ROADSIDE DETAIL SHT R-40 REMOVE AND REINSTALL CEMENT PEDESTRIAN CURB PER COR STD PLAN 101 REFER TO SD SHT SD-16 FOR STORM IMPROVEMENTS REMOVE AND REINSTALL THERMAL PLASTIC CROSSWALK LINE PER COR STD PLAN 127 1 2 3 4 5 6 17 19 20 SLOPE AS SHOWN (MAX 2.0% FINISHED SURFACE SLOPE) SLOPE AS SHOWN (MAX 8.3% FINISHED SURFACE SLOPE) TRUNCATED DOME DETECTABLE WARNING SURFACE 1.5% MAX. SLOPE LANDING IN ALL DIRECTIONS NEW S/W PANEL TO TRANSITION TO EXIST. S/W SLOPE AND WIDTH, MAX. 2% CROSS SLOPE AT TOP OF RAMP. TRANSITION CURB TO MATCH EXIST. CURB RAMP LEGEND 5 6 12.5' SAWCUT AND PAVEMENT PATCH LIMITS 2' MIN. FROM FACE OF CURB OR GUTTER PAN TO MEET CROSS SLOPE REQUIREMENTS (SEE TYPICAL SIDEWALK RAMP REPLACEMENT SECTION DETAIL, SHT. R-40) PAY LIMIT 20 ••••••••••••••••••••••••••••••••••RAD=111.42' Δ=1°24'31" L=2.7 RAD=20.25' Δ=39°23'07" L=13.9 RAD=20.25' Δ=14°11'18" L=5.0 RAD=18.03' Δ=26°22'53" L=8.3 STA F9+56, 43' RT BEGIN CURB AND GUTTER STA F9+78, 22' RT END CURB AND GUTTER •••••••••••••••••••••••••••••••••• EL=29.74 EL=29.79 EL=30.06± MATCH EXIST EL=30.42± MATCH EXIST EL=29.98± MATCH EXIST EL=29.87± MATCH EXIST TC=30.33 EXIST TC=29.77 TC=29.72 TC=30.47 EXIST TC=30.57 EXIST TC=30.52 TC=30.50 TC=30.46 EXIST FL=30.46 EXIST FL=29.89 FL=29.83 FL=30.57 EXIST FL=30.09 EXIST FL=29.72 FL=29.77 FL=29.83 EXIST EL=29.86± MATCH EXIST EL=29.91± MATCH EXIST RIM EL=29.71 1.7% 1.5% 1 .1% 1.5% 1 .0% 7.5%6.9%1.2%4.9%4.7%18-2251 R-37 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET CURB RAMP DETAILS - 7 ARC ARC TTT 117NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-CURB_RAMPS-R.dwg R-37 4/25/2023 9:04 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=5' SHATTUCK AVE S AND S 3RD PL - SW CORNER PLAN SCALE: 1"=5' SHATTUCK AVE S AND S 3RD PL - SW CORNER GRADING8.2'7.0' 7.3'6.9'6.9' 9.8'5.0 '13.2'5. 0 ' 16. 6 ' 15 1 16 4 3 16 18 4 4 19 2 6 17 KEY NOTES SAWCUT & REMOVE EXIST SIDEWALK CURB AND GUTTER TO NEAREST JOINT PAST MATCH LINE. CONSTRUCT PARALLEL CURB RAMP PER WSDOT STD PLAN F-40.12-03. FURNISH AND INSTALL RED DETECTABLE WARNING SURFACE PER WSDOT STD PLAN F-45.10-02 CONSTRUCT CEMENT CONC CURB PER COR STD PLANS 101 AND 103. CONSTRUCT CEMENT CONC SIDEWALK PER COR STD PLAN 102 INSTALL HMA TO MATCH EXIST PAVEMENT THICK, SEE ROADSIDE DETAIL SHT R-40 PROTECT EXIST HYDRANT REMOVE AND REINSTALL EXIST SIGN TO NEW METAL POST PER COR STD PLAN 129 REMOVE EXIST AND REINSTALL CEMENT CONC PEDESTRIAN CURB PER COR STD PLAN 101 RELOCATE EXIST TRASH OUT OF PROPOSED RAMP REFER TO SD SHT SD-16 FOR STORM IMPROVEMENTS REMOVE AND REINSTALL THERMAL PLASTIC CROSSWALK LINE PER COR STD PLAN 127 1 2 3 4 5 6 15 16 17 18 19 20 SLOPE AS SHOWN (MAX 2.0% FINISHED SURFACE SLOPE) SLOPE AS SHOWN (MAX 8.3% FINISHED SURFACE SLOPE) TRUNCATED DOME DETECTABLE WARNING SURFACE 1.5% MAX. SLOPE LANDING IN ALL DIRECTIONS CURB RAMP LEGEND 1 SAWCUT AND PAVEMENT PATCH LIMITS 2' MIN. FROM FACE OF CURB OR GUTTER PAN TO MEET CROSS SLOPE REQUIREMENTS (SEE TYPICAL SIDEWALK RAMP REPLACEMENT SECTION DETAIL, SHT. R-40) PAY LIMIT 20 20 RAD=20.53' Δ=47°18'03" L=17.0 RAD=19.42' Δ=14°47'43" L=5.0 RAD=26.62' Δ=22°56'14" L=10.7 STA F11+66, 19' LT BEGIN CURB AND GUTTER STA F11+88, 43' LT END CURB AND GUTTER TC=29.22 TC=29.27 TC=29.76 EXIST TC=29.84 EXIST TC=29.88 TC=29.90 TC=29.86 TC=29.75 TC=29.81 EXIST FL=29.32 EXIST FL=29.27 FL=29.22 FL=29.30 RIM EL=29.19 EL=29.32± MATCH EXIST EL=29.27± MATCH EXIST EL=29.51± MATCH EXIST EL=29.98± MATCH EXIST EL=29.40± MATCH EXIST EL=29.33± MATCH EXIST EL=29.47± MATCH EXIST EL=29.28 EL=29.23 FL=29.84 EXIST FL=29.37 FL=29.32 FL=29.86 FL=29.35 EXIST4.7%7.1%5.2 % 3.2 %1.5%2.2%1.1% 1.5% 1.5%1.0%1.0% 18-2251 R-38 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET CURB RAMP DETAILS - 8 ARC ARC TTT 118NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-CURB_RAMPS-R.dwg R-38 4/25/2023 9:04 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=5' SHATTUCK AVE S AND S 4TH ST - NE CORNER PLAN SCALE: 1"=5' SHATTUCK AVE S AND S 4TH ST - NE CORNER GRADING 4 2 11 17 3 5 1 1 4 4 4.0' 4.0'6.6'10.7'5.0 ' 17. 0 ' 10. 1 '5.0 ' 6.4' 6.3'7.3'6.7'7.0' 87 16 19 KEY NOTES SAWCUT & REMOVE EXIST SIDEWALK CURB AND GUTTER TO NEAREST JOINT PAST MATCH LINE. CONSTRUCT PARALLEL CURB RAMP PER WSDOT STD PLAN F-40.12-03 FURNISH AND INSTALL RED DETECTABLE WARNING SURFACE PER WSDOT STD PLAN F-45.10-02 CONSTRUCT CEMENT CONC CURB PER COR STD PLANS 101 AND 103. CONSTRUCT CEMENT CONC SIDEWALK PER COR STD PLAN 102 INSTALL HMA TO MATCH EXIST PAVEMENT THICK, SEE ROADSIDE DETAIL SHT R-40 ADJUST EXIST UTILITY BOX/VAULT/MH TO FINISHED GRADE, COORDINATE WITH CITY 4 WEEKS PRIOR TO CONSTRUCTION EXIST UTILITY BOX TO BE REMOVED, BY OTHERS PROTECT EXIST FENCE PROTECT EXIST UTILITY VAULT/BOX REMOVE AND REINSTALL EXIST SIGN WITH NEW METAL POST PER COR STD PLAN 129 REMOVE EXIST GRADE CURB REFER TO SD SHT SD-17 FOR STORM IMPROVEMENTS REMOVE AND REINSTALL THERMAL PLASTIC CROSSWALK LINE PER COR STD PLAN 127 1 2 3 4 5 6 7 8 11 13 16 17 19 20 SLOPE AS SHOWN (MAX 2.0% FINISHED SURFACE SLOPE) SLOPE AS SHOWN (MAX 8.3% FINISHED SURFACE SLOPE) TRUNCATED DOME DETECTABLE WARNING SURFACE 1.5% MAX. SLOPE LANDING IN ALL DIRECTIONS NEW S/W PANEL TO TRANSITION TO EXIST. S/W SLOPE AND WIDTH, MAX. 2% CROSS SLOPE AT TOP OF RAMP. TRANSITION CURB TO MATCH EXIST. CURB RAMP LEGEND 6 SAWCUT AND PAVEMENT PATCH LIMITS 2' MIN. FROM FACE OF CURB OR GUTTER PAN TO MEET CROSS SLOPE REQUIREMENTS (SEE TYPICAL SIDEWALK RAMP REPLACEMENT SECTION DETAIL, SHT. R-40) PAY LIMIT 20 12"DI SDRAD=55.01' Δ=6°56'22" L=6.7 RAD=20.22' Δ=48°30'10" L=17.1 RAD=18.67' Δ=15°23'18" L=5.0 RAD=18.67' Δ=20°10'17" L=6.6 STA F12+55, 22' LT END CURB AND GUTTER STA F12+32, 46' LT BEGIN CURB AND GUTTER 12"DI SD EL=28.99 EL=28.94 EL=29.22± MATCH EXIST EL=29.07± MATCH EXIST EL=29.22± MATCH EXIST EL=29.13± MATCH EXIST EL=29.47± MATCH EXIST EL=29.35± MATCH EXIST EL=29.95± MATCH EXIST TC=29.5 EXIST TC=28.97 TC=28.92 TC=29.56 TC=29.67 TC=29.62 TC=29.59 TC=29.6 EXIST FL=29.1 EXIST FL=28.97 FL=28.92 FL=29.11 FL=29.2 EXIST FL=29.67 FL=29.04 FL=29.09 FL=29.6 EXIST TC=29.7 EXIST RIM EL=28.90 6.9%6.5% 0.8% 1.5 %1.0%1.5 %1.0%1.5%3.0%3.0%5.2%3.9% 18-2251 R-39 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET CURB RAMP DETAILS - 9 ARC ARC TTT 119NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-CURB_RAMPS-R.dwg R-39 4/25/2023 9:04 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 SCALE: 1"=5' SHATTUCK AVE S AND S 4TH ST - SE CORNER PLAN SCALE: 1"=5' SHATTUCK AVE S AND S 4TH ST - SE CORNER GRADING 5.7' 7.4 ' 7.5 '6.7'7.7'6.9'10.3'5.017.1' 6.7'6.7'5.0'9.6' 4 7 1 2 7 8 3 5 8 9 4 19 17 KEY NOTES SAWCUT & REMOVE EXIST SIDEWALK CURB AND GUTTER TO NEAREST JOINT PAST MATCH LINE. CONSTRUCT PARALLEL CURB RAMP PER WSDOT STD PLAN F-40.12-03. FURNISH AND INSTALL RED DETECTABLE WARNING SURFACE PER WSDOT STD PLAN F-45.10-02 CONSTRUCT CEMENT CONC SIDEWALK PER COR STD PLAN 102 INSTALL HMA TO MATCH EXIST PAVEMENT THICK, SEE ROADSIDE DETAIL SHT R-40 ADJUST EXIST UTILITY BOX/VAULT/MH TO FINISHED GRADE, COORDINATE WITH CITY 4 WEEKS PRIOR TO CONSTRUCTION ADJUST EXIST UTILITY BOX/VAULT/MH TO FINISHED GRADE, BY OTHERS PROTECT EXIST STREET LIGHT. PROTECT EXIST CABINET PROTECT EXIST UTILITY VAULT/BOX REMOVE AND REINSTALL CEMENT CONCRETE PEDESTRIAN CURB PER COR STD PLAN 101 REFER TO SD SHT SD-17 FOR STORM IMPROVEMENTS REMOVE AND REINSTALL THERMAL PLASTIC CROSSWALK LINE PER COR STD PLAN 127 1 2 3 5 6 7 8 9 10 13 17 19 20 SLOPE AS SHOWN (MAX 2.0% FINISHED SURFACE SLOPE) SLOPE AS SHOWN (MAX 8.3% FINISHED SURFACE SLOPE) TRUNCATED DOME DETECTABLE WARNING SURFACE 1.5% MAX. SLOPE LANDING IN ALL DIRECTIONS NEW S/W PANEL TO TRANSITION TO EXIST. S/W SLOPE AND WIDTH, MAX. 2% CROSS SLOPE AT TOP OF RAMP. TRANSITION CURB TO MATCH EXIST. CURB RAMP LEGEND 13 10 6 1 SAWCUT AND PAVEMENT PATCH LIMITS 2' MIN. FROM FACE OF CURB OR GUTTER PAN TO MEET CROSS SLOPE REQUIREMENTS (SEE TYPICAL SIDEWALK RAMP REPLACEMENT SECTION DETAIL, SHT. R-40) PAY LIMIT 20 13 13 18-2251 R-40 of 121 RENTON DOWNTOWN UTILITY IMPROVEMENTS PROJECT January 2021AS SHOWN 1 10/26/2022JJM RECORD DRAWING RECORD DRAWINGS SEE NOTE ON COVER SHEET RESOTORATION AND TRENCH DETAILS ARC ARC TTT 120NO.DATE BY REVISION NOT TO SCALE THEN DRAWING IS NOT MEASURE 1" IF THIS BAR DOES NOTICE CHECKED DRAWN DESIGNED PROJECT NO.:SCALE:DATE:H:\EVT_Projects\18\2251 - Renton DUIP Phase 2\CAD\Sheets\18-2251-WA-CURB_RAMPS-R.dwg R-40 4/25/2023 9:04 AM DAVID.BARKER 24.1s (LMS Tech)SHEET 120 1 SIDEWALK RAMP GENERAL NOTES: 1. CONTRACTOR SHALL BE RESPONSIBLE FOR MEETING ALL AMERICANS WITH DISABILITIES (ADA) REQUIREMENTS AS DEFINED BY THE PUBLIC RIGHTS-OF-WAY ACCESSIBILITY GUIDELINES (PROWAG). SHOULD ANY ERROR OR INCONSISTENCY EXIST, THE CONTRACTOR SHALL NOT PROCEED WITH THE WORK AFFECTED UNTIL REPORTED TO THE ENGINEER FOR CLARIFICATION OR CORRECTION. 2. REFERENCE CITY OF RENTON STANDARD PLAN 101.0, 101.1, 102.0, AND 103.0. SEE WSDOT STD PLAN F-40.12-03, F-40.14-03, F-40.15.03, AND F-45.10-02. FOR ADDITIONAL INFORMATION. 3. ALL SURVEY AND STAKING NECESSARY FOR CONSTRUCTION SHALL BE PROVIDED BY THE CONTRACTOR. COMPLETE ALL SURVEY STAKING AS NEEDED USING INFORMATION CONTAINED IN THE PLANS AND ADJUSTED AS NECESSARY TO MEET ADA REQUIREMENTS. ADDITIONAL INFORMATION OR CLARIFICATION BY THE ENGINEER MAY BE AVAILABLE UPON REQUEST. SURVEYED FIELD LAYOUT SHALL BE REVIEWED BY THE CITY AND ENGINEER PRIOR TO CONCRETE PLACEMENT. 4. THE MAXIMUM CLOSURE TIME FOR ANY SINGLE CORNER SHALL BE ONE WEEK. SUBMIT TRAFFIC CONTROL PLAN AND PEDESTRIAN DETOUR PLAN FOR RAMP CLOSURES. PLAN SHALL INCLUDE BUT IS NOT LIMITED TO WORK AREA PROTECTION, SIDEWALK CLOSURES AND DETOURS. 5. COORDINATE UTILITY RELOCATIONS AND/OR ADJUSTMENTS AS NEEDED. SEE SPECIFICATIONS FOR UTILITY CONTACT INFORMATION. 6. REPLACE CURBS, SIDEWALKS, AND/OR DRIVEWAY APRONS THAT ARE DAMAGED AS A RESULT OF CONSTRUCTION OPERATIONS. REPLACE FULL SECTIONS TO THE NEAREST EXISTING CONSTRUCTION JOINT. REPLACEMENT WILL BE CONSIDERED INCIDENTAL TO THE WORK. 7. PROTECT FRESHLY POURED CONCRETE FROM VANDALISM OR OTHER DAMAGE FOR A MINIMUM OF TWENTY-FOUR (24) HOURS OR UNTIL CURED ENOUGH TO SUPPORT TYPICAL USE, WHICHEVER IS LONGER. ANY CONCRETE DAMAGED BY VANDALISM OR OTHER CAUSES SHALL BE REPLACED AT NO COST TO THE COUNTY. 8. ALL AREAS DISTURBED THROUGH THE CONSTRUCTION OF THE SIDEWALK RAMPS SHALL BE RETURNED TO THEIR ORIGINAL CONDITION PRIOR TO PROJECT COMPLETION. THIS INCLUDES, BUT IS NOT LIMITED TO, LANDSCAPE RESTORATION AROUND NEW RAMPS. LANDSCAPE RESTORATION WILL BE CONSIDERED INCIDENTAL TO THE WORK. 9. CONTRACTOR SHALL TAKE EXTRA CARE TO AVOID DAMAGING ANY IRRIGATION, WIRING, OR OTHER FACILITIES IN THE AREA TO THE NEW RAMP. ANY FACILITIES ENCOUNTERED SHALL BE RELOCATED BY THE CONTRACTOR WITHOUT DAMAGE TO AN APPROPRIATE LOCATION OUTSIDE THE RAMP/WALK AREA AT NO ADDITIONAL COST TO THE CITY. 1 -SCALE: NTS TYPICAL SIDEWALK RAMP REPLACEMENT SECTION NOTES: 1. TOOLED JOINTS ARE REQUIRED AT ALL SIDEWALK RAMP SLOPE BREAK LINES. 2. THE DETECTABLE WARNING SURFACE (DWS) SHALL BE PLACED AT BACK OF CURB WITH THE TWO LEADING CORNERS OF THE DWS PANEL PLACED ADJACENT TO THE BACK OF THE CURB, AND WITH NO MORE THAN A 2 INCH GAP BETWEEN THE DWS AND THE BACK OF THE CURB MEASURED AT THE CENTER OF THE DWS PANEL. EXCEPTION: IF THE MANUFACTURE OF THE SELECTED DWS REQUIRES A CONCRETE BORDER AROUND THE DWS, A VARIANCE OF UP TO 2 INCHES FROM THE BACK OF CURB IS PERMITTED (MEASURE AT THE LEADIND CORNERS OFF THE DWS PANEL) 24", MIN SAW CUT TRUNCATED DOME DETECTABLE WARNING SURFACE, 2' SEE NOTE 2 SLP VARIES, SEE DETAILS 4" CONC S/W 4" CSTCHMA CL 12" PG 64-22. MATCH EXIST THICKNESS 6" CSTC CONSTRUCT CEMENT CONC PEDESTRIAN CURB PER COR STD PLAN 101, WHERE SHOWN ON PLANS COUNTER SLP 5% MAX DEPRESSED CURB PER COR STD PLAN 101 CURB EXPOSURE = 0"VARIES2 -SCALE: NTS TYPICAL ROADWAY RESTORATION SECTION 3 -SCALE: NTS TYPICAL TRENCH, BEDDING AND BACKFILL SECTIONEXIST ASPHALT DEPTH VARIESIF REQUIRED BY THE ENGINEER, MIX DRY CEMENT INTO SUBGRADE, PAYMENT BY MINOR CHANGES COMPACTED SUBGRADE PIPE FOUNDATION STABILIZATION, IF REQUIRED SHALL BE 12"-24" CSBC AS DIRECTED BY THE ENGINEER WITH GEOTEXTILE WRAP W/18" OVERLAP BENCH AS NEEDED FOR SHORING SYSTEM EXIST ASPHALT,CONC, AND/OR BRICK DEPTH VARIESEXIST CONC OR BRICK 2" OVERLAY EXIST ASPHALT PERMANENT ASPHALT TO MATCH THICKNESS OF EXIST ROAD SECTION, 8" MIN UNDISTURBED NATIVE SOIL MIN 6" CSTC MIN 6" CSTC UNDISTURBED NATIVE SOIL ADDITIONAL CSTC DEPTH VARIES 8" PERMANENT ASPHALT PATCH EXIST ASPHALT 2" OVERLAY ASPHALT ONLY ROAD SECTION RESTORATION MULTIPLE MATERIAL ROAD SECTION RESTORATION GRAVEL BACKFILL FOR PIPE ZONE BEDDING PER WSDOT STD SPEC 9-03.12(3) TRENCH WIDTH PER SPECIAL PROVISION SECTION 7-08.3 6" CRUSHED SURFACING TOP COURSE PER WSDOT STD SPEC 9-03.9(3), BANK RUN GRAVEL FOR TRENCH BACKFILL PER WSDOT STD SPEC 9-03.19 OR GRAVEL BORROW PER WSDOT STD SPEC 9-03.14(1), COMPACTED TO 95% OF MAXIMUM DENSITY TRENCH BACKFILL PER DETAIL 3, THIS SHT 1' MIN 1' MIN NOTES: 1. TOOLED JOINTS ARE REQUIRED AT ALL SIDEWALK RAMP SLOPE BREAK LINES. 1.5%-2% OR AS DIRECTED BY ENGINEER 1.5% -2% OR AS DIRECTED BY ENGINEER 6" 1