Loading...
HomeMy WebLinkAboutMFP23006101.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP23006101 IVR Number: 23006101 Permit Information Permit Name: P.067586 Address/Location:12/08/2023Application Date:0823059167Parcel Number: 919 HOUSER WAY N Permit Type:01/03/2024Issue Date:Franchise Permit Work Class:01/02/2025Expiration Date:Minor Utility Job Number: P.067586Franchise Type:Telephone Description: Access HH UN 301 and HH 919 for splicing on Houser Way N. Contacts Name Address PhoneTypeBilling Nathan Macleod Lumen 7850 S Trafton St, Bldg B Tacoma, WA 98409 C: (253) 583-6283ApplicantX Merilyn Luong Lumen C: (206) 806-7160Applicant Michael Smith North Sky Communications 21320 84th Ave S Kent, WA 98032 C: (206) 305-5881Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES MFP23006101P.067586919 Houser Way N , Renton, WA, 980571/15/2023 1/19/2023 9am 4pm Northsky Communications Mike Smith Access HH UN-301 and HH 919 for splicing on Houser Way N. 425-615-7121 16701 SE McGillivray Blvd Vancouver, WA 98683 X X 3:00pm Scott Warlick CED 1/3/2024 12/21/2023 Merilyn Luong SCALE: PHONE: CHC ENGINEER: PHONE: EMAIL: A CONGRUEX COMPANYR DATE: PROJECT: AMO PROJECT: ADDRESS: CITY/STATE: ZIP: COUNTY: SHEET: REVISION: 949.250.0004 TCP@CHCCONSULTING.COM PR NO. TCP COVER SHEET 11/22/23 P.067586 0 KING COUNTY 98057 RENTON/WA 919 HOUSER WAY N.VIKRAM JAGGA N.T.S. LUMEN ENGINEER:ZACHARY THATCHER 253-797-4657 TRAFFIC CONTROL PLAN GENERAL NOTES 1.ALL WORK AND MATERIALS SHALL COMPLY WITH THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) AND WASHINGTON MODIFICATIONS, LATEST EDITION. 2.ALL STRIPING AND MARKINGS SHALL CONFORM TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) AND WASHINGTON MODIFICATIONS,,STANDARD PLANS AND SPECIFICATIONS. 3.THE CONTRACTOR SHALL PROVIDE FOR ACCESS TO ALL ADJACENT PROPERTIES, AND DRIVEWAYS AT ALL TIME. 4.FLASHING YELLOW BEACONS, TYPE "B", SHALL BE USED ON ALL W20-1 SIGNS AND ON ALL TYPE III BARRICADES GUARDING THE WORK AREA OVERNIGHT. 5.ALL SIGNS SHALL BE REFLECTORIZED AND STANDARD SIZE. 6.ALL TUBULAR DELINEATORS AND CONES SHALL BE 28" MINIMUM HEIGHT, REFLECTORIZED AND MAINTAINED ERECT IN THE INDICATED POSITION AT ALL TIMES, AND SHALL BE REPAIRED, REPLACED, OR CLEANED AS NECESSARY TO PRESERVE THEIR APPEARANCE AND CONTINUITY, AND SHALL INCLUDE A 12" HIGH-INTENSITY REFLECTORIZED SLEEVE, IF USED DURING NIGHT-TIME HOURS. 7.THE CONTRACTOR SHALL MAINTAIN, ON A CONTINUOUS BASIS, ALL SIGNS, DELINEATORS, BARRICADES, ETC., TO ENSURE PROPER FLOW AND SAFETY OF TRAFFIC DURING CONSTRUCTION. 8.THE CONTRACTOR SHALL HAVE ALL SIGNS, DELINEATORS, BARRICADES, ETC., PROPERLY INSTALLED PRIOR TO COMMENCING CONSTRUCTION. 9.CONSTRUCTION OPERATIONS SHALL BE CONDUCTED IN SUCH A MANNER AS TO CAUSE AS LITTLE INCONVENIENCE AS POSSIBLE TO ABUTTING PROPERTY OWNERS. 10.ADDITIONAL TRAFFIC CONTROLS, TRAFFIC SIGNS, OR BARRICADING MAY BE REQUIRED IN THE FIELD. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PLACEMENT OF ANY ADDITIONAL DEVICES NECESSARY TO ASSURE SAFETY TO THE PUBLIC AT ALL TIMES DURING CONSTRUCTION. 11.EXACT LOCATION AND TYPE OF CONSTRUCTION SIGNS SHALL BE DIRECTED BY THE ENGINEER BASED UPON CONSTRUCTION CONDITIONS. 12.MOVE DELINEATORS AND/OR CONES TO SIDEWALK DURING NON-WORKING HOURS. REMOVE BARRICADES ETC. FROM TRAVEL LANE. 13.REMOVE OR TURN OFF SIGNS DURING NON-WORK HOURS. 14.ALL CONFLICTING LINES, EXISTING CURB PAINT, AND MARKINGS SHALL BE REMOVED BY WET SANDBLASTING OR OTHER APPROVED METHOD PRIOR TO INSTALLATION OF NEW/TEMPORARY STRIPING. ALL CONFLICTING RAISED PAVEMENT MARKERS SHALL BE REMOVED. PAVEMENT THAT IS DAMAGED DUE TO REMOVAL OF MARKERS SHALL BE REPAIRED TO THE SATISFACTION OF THE CITY ENGINEER AND/OR STATE INSPECTOR. N PR- 592545 MFP23006101 SIDEWALK PARKINGPARKING PARKIN G SIDEWA L K 100'100' HH #919 HH UN #301 12' MAX. 12' MAX.12'12'T.A.N.S.A.T. FLAGGERFLAGGER ACCESS TO DRIVEWAYS MUST BE MAINTAINED AT ALL TIMES. FLAGGER TO ASSIST PEDESTRIANS THROUGH WORK AREA (SEE PED NOTES) HH UN #301 IS +/- 1885' N/W OF THE C/L OF N 8TH ST. CONTACT PROPERTY OWNER(S) 72 HOURS PRIOR TO START OF WORK. A DEDICATED INDIVIDUAL WILL BE ASSIGNED THE RESPONSIBILITY OF ESCORTING PEDESTRIANS THROUGH THE WORK AREA IN ACCORDANCE WITH THREE MAJOR CONSIDERATIONS: 1.PEDESTRIANS SHOULD NOT BE LED INTO DIRECT CONFLICT WITH WORK SITE VEHICLES, EQUIPMENT OR OPERATIONS 2.PEDESTRIANS SHOULD NOT BE LED INTO DIRECT CONFLICT WITH MAINLINE TRAFFIC MOVING THROUGH OR AROUND THE WORK SITE. 3.PEDESTRIANS SHOULD BE PROVIDED WITH A REASONABLY SAFE, CONVENIENT AND ACCESSIBLE PATH THAT REPLICATES AS NEARLY AS PRACTICAL THE MOST DESIRABLE CHARACTERISTICS OF THE EXISTING SIDEWALK OR FOOTPATH PEDESTRIAN CONTROL NOTES: SPEED LIMIT25 HOUSER WAY N. SPEED LIMIT25 HOUSER WAY N. 45' SHOULDER TAPER 50' BUFFER 25' MAX.12'11/22/23 P.067586 0 KING COUNTY 98057 RENTON/WA 919 HOUSER WAY N.VIKRAM JAGGA SCALE: PHONE: CHC ENGINEER: PHONE: EMAIL: A CONGRUEX COMPANYR DATE: PROJECT: AMO PROJECT: ADDRESS: CITY/STATE: ZIP: COUNTY: SHEET: REVISION: 949.250.0004 TCP@CHCCONSULTING.COM PR NO.1:40 CHANNELIZING DEVICE S FLAGGER EXISTING DRIVEWAY HIGH LEVEL WARNING DEVICE (FLAGTREE) FLASHING ARROW BOARD SIGNALIZED INTERSECTION TOW AWAY NO STOPPING ANY TIME TYPE III BARRICADE W/SIGN TYPE II BARRICADE W/SIGN TYPE I W/ SIGN TRAFFIC CONE WITH CLIP ON SIGN DIRECTION OF TRAFFIC (NOT PAVEMENT MARKING) PORTABLE FLASHING BEACON (P.F.B.) WORK ZONE (ACTIVITY AREA) LIMITS EXISTING SIGN OF TC-1 LUMEN ENGINEER:ZACHARY THATCHER 253-797-4657 PR- 592545 TC-1 919 HOUSER WAY N. HOUSER WAY N. AND N 8TH ST. -HH UN #301 & HH #919 ACCESS WORK AREA 1 OF 1 MFP23006101 © 2023 Microsoft Corporation © 2023 TomTom EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: RNTNWAISSECTION: 8TOWNSHIP: 23NRANGE: 5ECUSTOMER INFORMATIONNAME: DISH WIRELESSCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: ZACHARY THATCHERPHONE: 253-797-4657CONTRACT ENGINEERCHC ENGINEER: SANDESH YADAVPHONE: 949-250-0004SCALE:JOB: P.067586DATE:SHEET: OF 3REVISION: 1CALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 919 HOUSER WAY N12/06/2023CONSTRUCTION NOTES:1.CALL UTILITY LOCATE AT 811 72 HOURS PRIOR TO TRENCHING OR DIGGING.2.THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES ORSTRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY FIELD INSPECTIONAND A SEARCH OF THE AVAILABLE CITY OR COUNTY RECORDS. SINCE THEACTUAL LOCATION AND NATURE OF THE UNDERGROUND FACILITIES MAY BESOMEWHAT DIFFERENT FROM THAT SHOWN. THE CONTRACTOR IS REQUIRED TOVERIFY PRIOR TO EXCAVATION.3.FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULTPRIOR TO ENTRY. PLACE WARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL, STATE,AND LOCAL REGULATIONS.4.ALL EXCAVATION, TRENCHING, AND SHORING IS TO ADHERE TO THE CODE OFFEDERAL REGULATIONS (CFR) 1926.650 SUBPART P.a. PROVIDE ALL PITS WITH 1'X1' SLOPE AT ONE END OF EXCAVATION FOR TECHNICIAN INGRESS/EGRESS.b. EXCAVATED SPOILS ARE TO BE NO LESS THAN 24" FROM EDGE OF PIT OR TRENCH.c. BARRICADE ALL OPEN PITS AND TRENCHING FOR PUBLIC SAFETY. ALLBARRICADES MUST BE EQUIPPED WITH FLASHING LIGHTS FOR NIGHT VISIBILITY.d. FOR PITS GREATER THAN 4' IN DEPTH, USE APPROPRIATE SHORING FOR WALL STABILITY5.TRENCH COVER IS TO BE 36" MINIMUM AND FREE OF ROCKS, DEBRIS, AND CLODS.THE TRENCH IS TO BE A MINIMUM OF 36" COVER IN DEVELOPED AREAS AND AMINIMUM OF 48" OF COVER IN UNDEVELOPED AREAS (ANY VARIANCE FROM THESESTANDARDS WILL BE SPECIFIED ON THE PLANS).6.ALL ASPHALT/CONCRETE AND LANDSCAPING REMOVED, DISTURBED, OR DAMAGESAS A RESULT OF CONSTRUCTION SHALL BE RESTORED TO ORIGINAL CONDITIONOR BETTER.7.NORMAL/GUIDED-BORING METHOD RECOMMENDED WHEN BORING.8.ADHERE TO AIRTIGHT GUIDELINES UNLESS OTHERWISE NOTED.9.BOND BURIED/AERIAL FACILITIES AS REQUIRED BY JURISDICTIONAL AGENCY(S).10.AERIAL FACILITIES ARE TO BE TESTED PRIOR TO BEGINING WORK PER STATE ANDLOCAL REGULATIONS.11.ALL WORK AREA PROTECTION FOR TRAFFIC CONTROL IS TO BE WITH APPROVEDWARNING DEVICES AND PLACED PER STATE DEPARTMENT OF TRANSPORTATIONAND/OR PUBLIC WORKS ENGINEERING DEPARTMENT STANDARDS ANDSPECIFICATIONS. IF REQUIRED, A TRAFFIC CONTROL PLAN SHALL BE SUBMITTEDTO THE REQUESTING PERMITTING AGENCY. PRIOR TO BEGINNING WORK,PERMITTING AGENCIES MUST BE NOTIFIED 48 HOURS IN ADVANCE OFCONSTRUCTION ACTIVITIES.12.EXISTING PEDESTRIAN CROSSWALKS AND WALKING AREAS SHALL BE MAINTAINEDAT ALL TIMES. AS NECESSARY, TEMPORARY PEDESTRIAN CROSSWALKS ANDWALKING AREAS SHALL BE PROVIDED AND MAINTAINED PER STATE DEPARTMENTOF TRANSPORTATION AND/OR PUBLIC WORKS ENGINEERING DEPARTMENTSTANDARDS AND SPECIFICATIONS.13.THE FOLLOWING FOOTAGES ARE ESTIMATES. FOOTAGES TO BE VERIFIED PRIORTO CONSTRUCTIONS.PERMITSYES /NODESIGNED SERVICES:HELD ORDERS:ROW REQUIRED:CITY:COUNTY:STATE:RAILROAD:LOOP QUAL.:PREMIS FORM:ADDITIONAL PERMIT INFO:CONFORMANCE TEST:SEE NDSERFS DATETRENCH OPEN DATE:----APPROVED MNEMONICS:ASSOCIATED PROJECTS:LCON NAME: NALCON NUMBER: NAFIBER ENGINEER: ZACHARY THATCHERFIBER ENGINEER CONTACT: 253-797-4657FIELD ENGINEER: JUSTIN CUTHBERTFIELD ENGINEER CONTACT:GLADSTONEENGINGEERINGLLC@GMAIL.COMCUSTOMER NAME: DISH WIRELESSADDRESS:919 HOUSER WAY N, RENTON, WA, 98057EQUIPMENT: (1) 12 PORT FDP, (1) CIENA 3931, (+/- 80' UG) FIBER (1) SPLICE CASE.NOTES: NA.NARRATIVE:PLACEMENT: PLACEMENT STARTS FROM PED BD7CMPH [KC30]. PULL NEW FIBER FROM PED BD7CMPH [KC30] TO DISH HH TO MPOP THROUGH CUSTOMER PROVIDED CONDUIT. PLACE NEW 12 PORT FDP AND CIENA 3931 ON H-FRAME AT DISH CELL SITE.SPLICING: AT EXISTING POF HH 919. SPLICE FROM EXISTING FIBER TO EXISTING FIBER. BD7CMPH, SPLICE EXISTING FIBER TO NEW FIBER. RING CUT EXISTING FIBER FOR NEW SPLICE CASE. CELL SITE (H-FRAME), TERMINATE FROM NEW FIBER TO NEW 12 PORT FDP.CUSTOMER REQUIREMENTS: CUSTOMER TO PLACE NEW H-FRAME (CELL SITE). PROVIDE POWER SUPPLY ON PROPOSED H-FRAME. PLACE NEW GROUND SOURCE ON PROPOSED H-FRAME. DISH TO PLACE NEW HH.VICINITY MAP1NTSWHOLESALE - FTTTI-405HOUSER WAY NRAIL ROADCUSTOMER919 HOUSER WAY NREVISION 1 (12/06/2023):- DESIGN UPDATED AS PER LATEST STANDARD OF FTTTJOB.POFHH 919MFP23006101 EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: RNTNWAISSECTION: 8TOWNSHIP: 23NRANGE: 5ECUSTOMER INFORMATIONNAME: DISH WIRELESSCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: ZACHARY THATCHERPHONE: 253-797-4657CONTRACT ENGINEERCHC ENGINEER: SANDESH YADAVPHONE: 949-250-0004SCALE:JOB: P.067586DATE:SHEET: OF 3REVISION: 1CALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 919 HOUSER WAY N12/06/20232NTSC/LC/LC/LC/LC/LC/LC/LC/L C/LC/LEATELEPHONE BULLET PEDESTALTELEPHONE REPEATERTELEPHONE PEDESTALTELEPHONE VAULT/HANDHOLETELEPHONE CABINETTELEPHONE MANHOLETELEPHONE COOL PEDTELEPHONE SAITELEPHONE USAMTELEPHONE OWNED POLEJOINT USE POLEACCESS POINTAERIAL SPLICE CLOSUREVERTICAL GROUNDGAS METERGAS VALVETRAFFIC SIGNAL VAULT/HANDHOLETRAFFIC SIGNAL POLEWATER METERWATER VALVEFIRE HYDRANTWATER MANHOLESTORE DRAIN CATCH BASINSTORM DRAIN INLETSTORM DRAIN MANHOLEIRRIGATION METERIRRIGATION VALVECULVERTC/L MONUMENTPOLE ITEM NO.XX'XX'XX'XX'MHTEAUSAMMHTHH HHEPWREEETVTVSVTSVWSDVCENTERLINERIGHT OF WAYPROPERTY LINEEASEMENTCURB & GUTTEREDGE OF PAVEMENTRAILROADFENCETELCOELECTRICCATVGASTRAFFIC SIGNALWATERSEWERSTORM DRAINIRRIGATIONEXISTING AERIAL OR UNDERGROUND FIBEREXISTING AERIAL STRAND2'x2' RECEIVING PIT4'x4' BORE PITSAICOOL PEDESTALELECTRIC PEDESTALTELCO HANDHOLETELCO PEDESTALTELCO CABINETTELCO MANHOLER/WEOPTECATVGASTSWSC/LP/LP#HH HHELECTRIC PEDESTAL/CABINETELECTRIC TRANSFORMERELECTRIC METERELECTRIC VAULT/HANDHOLEELECTRIC MANHOLEELECTRIC J-BOXSTREETLIGHTCATV BULLET PEDESTALCATV PEDCATV VAULT/HANDHOLESEWER MANHOLELIGHT TREE TRIMMEDIUM TREE TRIMHEAVY TREE TRIMLMHTRENCHBOREASPHALT TRENCHAERIAL BUILDAERIAL BUILDSLACK SPANAERIAL STRANDANCHOR & DOWN GUYDOWN GUYASPHALT TRENCH FOOTAGEDIRT OR S/W TRENCH FOOTAGEBORE FOOTAGEAERIAL FOOTAGEANCHOR & DOWN GUYUNDERGROUND FIBER PLACEMENT THROUGH EXISTING CONDUITSDIRRIGMFP23006101 HOUSER WAY NEOPEOPEOPEOPEOPEOPC/LC/LC/LC/LC/LC/LR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WP/LP/LP/LP/LR/WR/WR/WR/WR/WR/WR/WParcel #:0823059168Parcel #:0823059167Parcel #:0823059218Parcel #:6145601126SidewalkD/WDirt GrassDirtEOPEOPFenceEOPP/LP/LSidewalkD/WEOPD/WI-405DISH HH- (In Asphalt)- Pass ThroughMPOP05+53Pull new fiber from PEDBD7CMPH [KC30] to DISHHH to MPOP throughCustomer provided conduit.PLACE NEW 12 PORT FDP AND CIENA3931 ON H-FRAME AT DISH CELL SITE.CUSTOMER:919 HOUSER WAY NHHHH HH HHVICINITY MAPNSOUTHPORTDR NNESUNSETBLVDHOUSER WAY NI-405R.R.Existing Fiber00+0004+73HH HHSPEEDLIMIT25SPEEDLIMIT25HH UN-301- (4' from EOP)- Pass ThroughPOFHH 919- (9' from EOP)- Splice Location- 655' Southeast from SOUTHPORTDR N & HOUSER WAY N IntersectionPED BD7CMPH [KC30]- (In Asphalt)- Splice Location- Place new splice case01+7805+0113'19'ParkingParkingSPEEDLIMIT60Existing FiberHHHHHHHHHHHHHH UN-301HH 919PED BD7CMPH[KC30]DISH HHRailTracksCELLSITEDirt Grass13'8'19'40'60'60'40'8'EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: RNTNWAISSECTION: 8TOWNSHIP: 23NRANGE: 5ECUSTOMER INFORMATIONNAME: DISH WIRELESSCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: ZACHARY THATCHERPHONE: 253-797-4657CONTRACT ENGINEERCHC ENGINEER: SANDESH YADAVPHONE: 949-250-0004SCALE:JOB: P.067586DATE:SHEET: OF 3REVISION: 1CALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 919 HOUSER WAY N12/06/202331" = 30'MFP23006101This work is on privateproperty and may requireadditional approval fromthe property owner.