O AdN CROSS ENGINEERS, INC
r;
923 MILK Jr. Way Phone: (253) 759-0118
O . Tacoma, WA 98405 Job Number: 20-008
z info@crossengineers.com
O
RECORD DRAWING
0 THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED
IN PART ON INFORMATION PROVIDED BY OTHERS.
CHANGES SHOWN HAVE BEEN PROVIDED BY THE
> CONTRACTOR AND HAVE NOT BEEN VERIFIED BY THE
c/) LICENSED ENGINEER OR LANDSCAPE ARCHITECT.
Z)
_J
WSP USA Inc.
33301 9th Avenue South
Suite 300
Federal Way, WA 98003-2600
TEL: (206) 431-2300
FAX: (206) 431-2250
EXISTING BRIDGE DEMO ELECTRICAL PLAN
SCALE: 1" = 5-0"
ENL•y
0029060
/STERF'�
ss�ONAL
N0.
RECORD DRAWINGS
G11aY16`1IM101
GRAPHIC SCALE
5 0 5 10
1 "=5'-0"
scale feet
SJK h 1 /17/23 SLH ' SURVEYED:
DESIGNED:
GLW
DRAWN:
JAE
CHECKED:
GLW
BY DATE APPR APPROVES
SCALE:
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
GENERAL NOTES:
1. ELECTRICAL REQUIREMENTS ARE NOT LIMITED TO ELECTRICAL DRAWINGS.
THERE IS ADDITIONAL ELECTRICAL WORK REQUIRED TO BE INCLUDED IN THE
BID, INDICATED ON STRUCTURAL AND CIVIL DRAWINGS AND IN THE
SPECIFICATIONS. CONTRACTOR SHALL REVIEW ALL DRAWINGS, SPECIFICATIONS
AND INCLUDE COSTS FOR ELECTRICAL WORK IN THE BID.
2. CONTRACTOR SHALL REVIEW AND COORDINATE ALL TRENCHING WITH BRIDGE
CONCRETE ABUTMENT CONSTRUCTION. CONDUIT SLEEVES ARE PROVIDED IN
CONCRETE ABUTMENT FOR ELECTRICAL.
3. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE LOCATION AND
PROTECTION OF ALL EXISTING UTILITIES. THE CONTRACTOR SHALL VERIFY ALL
UTILITY LOCATIONS PRIOR TO CONSTRUCTION BY CALLING THE UNDERGROUND
LOCATE LINE AT 1-(800)-424-5555 A MINIMUM OF 48 HOURS PRIOR TO ANY
EXCAVATION. THE CONTRACTOR WILL ALSO BE RESPONSIBLE FOR MAINTAINING
ALL LOCATE MARKS ONCE THE UTILITIES HAVE BEEN LOCATED.
4. CONTRACTOR SHALL OBTAIN AND PAY FOR PROJECT ELECTRICAL PERMIT WITH
AUTHORITY HAVING JURISDICTION (AHJ). ALL WORK SHALL COMPLY WITH
CURRENT NATIONAL ELECTRICAL CODE AND WASHINGTON ADMINISTRATIVE
CODE.
5. HAND DIGGING WILL BE REQUIRED. ALL CONDUITS SHALL BE BEDDED 3" MINIMUM
ALL SIDES, IN CLEAN FREE FLOWING, COURSE GRADE SAND AS DEFINED IN ASTM
D 2487. COMPACT TO 95%. PROVIDE ELECTRICAL WARNING TAPE 12" BELOW
FINISHED GRADE OVER CONDUITS.
ELECTRICAL NOTES:
F:::___ REMOVE EXISTING 1-1/2"PVC CONDUIT AND WIRE SURFACE MOUNTED TO UNDERSIDE OF
EXISTING BRIDGE TO BE REMOVED. PRIOR TO BRIDGE DEMOLITION FIELD VERIFY POWER
SOURCE FOR SITE LIGHTING AND SAFE -OFF. IN EACH HANDHOLE DISCONNECT AND
REMOVE ALL WIRING CROSSING BRIDGE TO BE REMOVED. PROVIDE WATER TIGHT CAPS
ON EXISTING WIRES REMAINING UNTIL NEW BRIDGE CONSTRUCTION IS COMPLETED.
CITY OF
RENTON
R-420240
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
GENE COULON MEMORIAL BEACH PARK
TRESTLE BRIDGE REPLACEMENT
EXISTING BRIDGE DEMO ELECTRICAL PLAN
DATE:
F 1L B/17/20
PAGE: PAGE
DRAWING NO:
E-1
SHEET: OF:
— 38