Loading...
HomeMy WebLinkAboutR-3940300 B 01 F G L'I J r THE AUTO SUPERSTORE CARMAX Auto Super Stores, Inc. Civil Permit Set Renton, WA LUA15-000288 STORE 7252 PROJECT TEAM OWNER CIVIL ENGINEER CARMAX AUTO SUPERSTORE WEST COAST PACLAND 12800 TUCKAHOE CREEK PARKWAY 1505 WESTLAKE AVENUE N., SUITE 305 RICHMOND, VA 23238-1115 SEATTLE, WA 98109 PHONE: 804.747.0422 PHONE: 206.522.9510 FAX: 804.935.4547 FAX: 206.522.8344 CONTACT: LANCE MASON CONTACT: BILL FORTUNATO, P.E. ENTITLEMENTS CONSULTANT SURVEYOR CENTERPOINT INTEGRATED SOLUTIONS, LLC KENT, WA 98032 1240 BERGEN PKWY, SUITE A-250 PACE ENGINEERS EVERGREEN, CO 80439 11255 KIRKLAND WAY, SUITE 300 PHONE: 303.679.6975 KIRKLAND, WA 98033 FAX: 303.670.4172 PHONE: 425.827.2014 CONTACT: AMANDA STEINLE FAX: 425.827.5043 425.430-7382 CONTACT: DAVE FULTON ARCHITECT/ SITE PLANNER CONTACT: ANN FOWLER CONTACT: ANN FOWLER GEOTECHNICAL ENGINEER TERRY L. HERR, AIA ARCHITECT IN Is by. ASSOCIATION WITH PIEPER, O'BRIEN, HERR ARCHITECTS ZIPPER GEO ASSOCIATES, LLC 3000 ROYAL BLVD. SOUTH 19023 36TH AVENUE W., SUITE D ALPHARETTA, GA 30022 LYNNWOOD, WA 98036 PHONE: 770.569.1706 425.582.9928 FAX: 770.569.1786 CONTACT: JAMES P. GEORGIS, L.E.G. CONTACT: IAN HALSEY LIST OF CONTACTS U16003156 GENERAL NOTES 1. TOTAL CUSTOMER/EMPLOYEE PARKING SPACES: REQUIRED = 48 SPACES PROVIDED = 348 SPACES 2. CUSTOMER/EMPLOYEE PARKING SPACE SIZE: REQUIREMENTS = 9'X20' PROVIDED = 9'X20' SITE PARCEL I.D. NOS: INDUSTRIAL MEDIUM (IM): 1253600030 3. SITE ADDRESS = 3751 EAST VALLEY ROAD; RENTON, WA 4. TOTAL SITE ACREAGE = 12.28 ACRES 5. TOTAL DISTURBED ACREAGE = 10.81 ACRES 6. AREA BREAKDOWN: BUILDING = 20,217 SF= 3.8% PAVEMENT/IMPERVIOUS = 357,732 SF= 66.9% LANDSCAPE/GRASSED = 129,618 SF = 24.2% DETENTION PONDS = 27,350 SF = 5.1% TOTAL = 534,917 SF = 100% 7. SITE LIES WITHIN FEMA REGULATORY ZONE A. 8. ALL VEHICLE LOADING AND UNLOADING IS TO OCCUR IN THE CARRIER LOADING ZONE. ANY USE OF PUBLIC SPACE WILL REQUIRE PERMITTING WITH THE CIN OF RENTON. 9. USE PERMITTED UNDER RMC 4-2-080 A.29 STORM DRAINAGE, SANITARY SEWER, GAS SITE PLANNING&ZONING PUBLIC WORKS DEPARTMENT & DOMESTIC WATER 11,138 SF _ of tes8j,1�T2 PRESENTATION: PUGET SOUND ENERGY RENTON CITY HALL RENTON CITY HALL CITY OF RENTON 8001 S. 212TH ST. PLANNING& COMMUNITY DEVELOPMENT PUBLIC WORKS DEPARMTENT PUBLIC WORKS DEPARMTENT KENT, WA 98032 1055 S. GRADY WAY 1055 S. GRADY WAY 1055 S. GRADY WAY 405 SPACES RENTON, WA 98057 RENTON, WA 98057 RENTON, WA 98057 POWER 425.430.6598 425.430-7382 425.430-7382 CONTACT: JILL DING CONTACT: ANN FOWLER CONTACT: ANN FOWLER PUGET SOUND ENERGY ADProved Is by. 6905 S. 228TH ST. BUILDING DEPARTMENT FIRE DEPARTMENT KENT, WA 98032 CV -1.0 NOTES & INFORMATION SHEEr RENTON CITY HALL 425.430.7024 BUILDING CODE OFFICIAL CONTACT: COREY THOMAS 1055 S. GRADY WAY RENTON, WA 98057 425.430.7290 CS -1.0 EXISTING CONDITIONS PLAND-1.0 CONTACT: CRAIG BURNELL ■■■■■■■■■■ L "S(2)/M" ANK CLp SALES 11,138 SF _ of tes8j,1�T2 PRESENTATION: 2,022 SF CAR WASH , , �3�5 _ 20,216 SF PARKING SPACES m. s Approved Approved by by SALES (9' WIDE) 405 SPACES 1505 Westlake Ave. N. T (2D6) 522-9510 �O •y& P�18T6ggo .g 9yy ® APProvad by Supe 305 F (206) 522-8344 AL 8F Seattle. WA 98109 wxw.P4dxlo.ox� mown ADProved Is by. CITY OF RENTON _ Date--- Date-- Date--- Date-- NO. ate-__Date__Date-_Date NO. REVISION PROJECT DATA BOX ij BUILDING PROTO DESIGNATION: "S(2)/M" AREA: SALES 11,138 SF SERVICE (M): 61137 SF PRESENTATION: 2,022 SF CAR WASH 919 SF TOTAL: 20,216 SF PARKING SPACES CUSTOMER/EMPLOYEE (9' WIDE) 348 SPACES SALES DISPLAY SALES (9' WIDE) 405 SPACES LEGAL DESCRIPTION SEE SHEET CV -1.1 FOR LEGAL DESCRIPTION. HEARING EXAMINER CONDITIONS OF APPROVAL SEE SHEET CV -1.1 FOR HEARING EXAMINER CONDITIONS OF APPROVAL SEPA MITIGATION CONDITIONS SEE SHEET CV -1.1 FOR SEPA MITIGATION CONDITIONS. ENGINEERS CONSTRUCTION RECORD CERTIFICATION THIS PLAN HAS BEEN REVIEWED FOR CONFORMANCE NTH THE DESIGN INTENT. THIS PLAN, AS MODIFIED HEREIN, REPRESENTS THE RECORD CONDITIONS OF THE NEW CONSTRUCTION SHOWN, BASED UPON AN AS -BUILT SURVEY PREPARED BY INFORMED LAND SURVEY, DATED 9/5/17 AND 9/20/17. THIS DOCUMENT DOES NOT REPRESENT A DETAILED FIELD SURVEY. THE ENGINEER HEREBY CERTIFIES THAT, BASED UPON THE METHODOLOGY DESCRIBED ABOVE, CONSTRUCTION SHOWN IS CONSISTENT WITH THE DESIGN INTENT EXCEPT AS NOTED, AND ACCURATELY REPRESENTS THE EXISTING CONDITIONS, PER CONTRACTOR AND SURVEYOR PROVIDED RECORD INFORMATION. PACLAND CERTIFICATION BY VFF� DATE 47-1b- 7-7 1. REFER TO THE GEOTECHNICAL ENGINEERING REPORT, DATED FEBRUARY 7, 2014s AND SUPPLEMENTAL GEOTECHNICAL DATA REPORT, DATED MAY 6, 2016, PREPARED BY ZIPPER GEO NOTES: ASSOCIATES AND INCLUDED AS PART OF THE CONSTRUCTION DOCUMENTS. 1. SITE WORK FOR THIS PROJECT SHALL MEET OR EXCEED THE PROJECT SPECIFICATIONS, CURRENT WSDOT SPECIFICATIONS, AND CITY OF RENTON STANDARDS WHICH ARE HEREBY REFERENCED AS PART OF THESE PLANS. 2. THE DESIGN SHOWN IS BASED UPON THE ENGINEER'S UNDERSTANDING OF THE EXISTING CONDITIONS. THE PLAN DOES NOT REPRESENT A DETAILED FIELD SURVEY. THE EXISTING CONDITIONS SHOWN ON THIS PLAN SHEET ARE BASED UPON THE SURVEY PREPARED BY PACE ENGINEERS, INC., DATED 1/16/2015. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING FIELD CONDITIONS PRIOR TO BIDDING THE PROPOSED SITEWORK IMPROVEMENTS. IF CONFLICTS ARE DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE OWNER PRIOR TO INSTALLATION OF ANY PORTION OF THE SITEWORK WHICH WOULD BE AFFECTED. IF CONTRACTOR DOES NOT ACCEPT EXISTING SURVEY, INCLUDING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, HE SHALL HAVE MADE, AT HIS OWN EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR AND SUBMIT IT TO THE OWNER FOR REVIEW. 3. CAUTION - NOTICE TO CONTRACTOR THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANY AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS. 4. ALL NECESSARY INSPECTION AND/OR CERTIFICATIONS REWIRED BY CODES AND/OR UTILITY SERVICE COMPANIES SHALL BE PERFORMED PRIOR TO ANNOUNCED BUILDING POSSESSION AND THE FINAL CONNECTION OF SERVICES. 5. SITE WORK FOR THIS PROJECT SHALL BE CONSTRUCTED PER THE APPROVED, SIGNED CONSTRUCTION PLANS. ELECTRONIC FILES SHALL NOT BE CONSIDERED CONSTRUCTION DOCUMENTS UNLESS SPECIFICALLY STATED AS SUCH AND HANDLED IN ACCORDANCE WITH THE BID DOCUMENTS, SIGNED PAPER PLANS SHALL TAKE PRECEDENCE OVER ELECTRONIC FILES. 6. THE CONTRACTOR SHALL MAINTAIN A SET OF THE CONSTRUCTION PLANS ON-SITE AT ALL TIMES WHILE CONSTRUCTION IS IN PROGRESS. AS NOTED »lml"' & CITY OF CA STORE NO. 7252 "i1/os/17 W" RENTON ----- .� THE AUTO SUPERSTORE � DATUM NOTES & INFORMATION w WF Planning/Building/Public Works Dept. CV -1.O BY DATE APPR WF � AS -BUILT w R-394030 16 0 0 315 6 SHEET INDEX ■■■■■■■■■■ CV -1.0 NOTES & INFORMATION SHEEr CS -1.0 EXISTING CONDITIONS PLAND-1.0 ■■■■■■■■■■ DEMOLITION PLAN D-1.1 EROSION CONTROL PLAN, PH. I D-1.2 EROSION CONTROL PLAN, PH. 11 EROSION CONTROL DIFTAILSC-6.3 ■■■■■■■■■■ EROSION CONTROL DIFTAILS C-1.1 SITE DIMENSIONS PLAN C-1.3 LIGHT POLE LOCATION PLAN C-2.0 GRADING AND DRAINAGE PLAN C-2.1 STORM DRAINAGE PROFILES STORM DRAINAGE DETAILS WATERD-2.1 NOTES& DETAILSC-B.2 ■■■■■■■■■■ SITE DETAILS SITE DETAILS C-9.0 DETAILSC-B.1 SITE ■■■■■■■■■■ C-9.2 SITE DETAILS L-1.0 LANDSCAPE PLAN L-2.0 IRRIGATION PLAN 1. REFER TO THE GEOTECHNICAL ENGINEERING REPORT, DATED FEBRUARY 7, 2014s AND SUPPLEMENTAL GEOTECHNICAL DATA REPORT, DATED MAY 6, 2016, PREPARED BY ZIPPER GEO NOTES: ASSOCIATES AND INCLUDED AS PART OF THE CONSTRUCTION DOCUMENTS. 1. SITE WORK FOR THIS PROJECT SHALL MEET OR EXCEED THE PROJECT SPECIFICATIONS, CURRENT WSDOT SPECIFICATIONS, AND CITY OF RENTON STANDARDS WHICH ARE HEREBY REFERENCED AS PART OF THESE PLANS. 2. THE DESIGN SHOWN IS BASED UPON THE ENGINEER'S UNDERSTANDING OF THE EXISTING CONDITIONS. THE PLAN DOES NOT REPRESENT A DETAILED FIELD SURVEY. THE EXISTING CONDITIONS SHOWN ON THIS PLAN SHEET ARE BASED UPON THE SURVEY PREPARED BY PACE ENGINEERS, INC., DATED 1/16/2015. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING FIELD CONDITIONS PRIOR TO BIDDING THE PROPOSED SITEWORK IMPROVEMENTS. IF CONFLICTS ARE DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE OWNER PRIOR TO INSTALLATION OF ANY PORTION OF THE SITEWORK WHICH WOULD BE AFFECTED. IF CONTRACTOR DOES NOT ACCEPT EXISTING SURVEY, INCLUDING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, HE SHALL HAVE MADE, AT HIS OWN EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR AND SUBMIT IT TO THE OWNER FOR REVIEW. 3. CAUTION - NOTICE TO CONTRACTOR THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANY AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS. 4. ALL NECESSARY INSPECTION AND/OR CERTIFICATIONS REWIRED BY CODES AND/OR UTILITY SERVICE COMPANIES SHALL BE PERFORMED PRIOR TO ANNOUNCED BUILDING POSSESSION AND THE FINAL CONNECTION OF SERVICES. 5. SITE WORK FOR THIS PROJECT SHALL BE CONSTRUCTED PER THE APPROVED, SIGNED CONSTRUCTION PLANS. ELECTRONIC FILES SHALL NOT BE CONSIDERED CONSTRUCTION DOCUMENTS UNLESS SPECIFICALLY STATED AS SUCH AND HANDLED IN ACCORDANCE WITH THE BID DOCUMENTS, SIGNED PAPER PLANS SHALL TAKE PRECEDENCE OVER ELECTRONIC FILES. 6. THE CONTRACTOR SHALL MAINTAIN A SET OF THE CONSTRUCTION PLANS ON-SITE AT ALL TIMES WHILE CONSTRUCTION IS IN PROGRESS. AS NOTED »lml"' & CITY OF CA STORE NO. 7252 "i1/os/17 W" RENTON ----- .� THE AUTO SUPERSTORE � DATUM NOTES & INFORMATION w WF Planning/Building/Public Works Dept. CV -1.O BY DATE APPR WF � AS -BUILT w R-394030 16 0 0 315 6