Loading...
HomeMy WebLinkAboutEX_06_C_Advisory_NotesDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 of 1 LUA**-000*** ADVISORY NOTES TO APPLICANT The following notes are supplemental information provided in conjunction with the administrative land use action. Because these notes are provided as information only, they are not subject to the appeal process for the land use action. Planning: (Contact: Jill Ding, 425-430-6598, jding@rentonwa.gov) 1. RMC section 4-4-030.C.2 limits haul hours between 8:30 am to 3:30 pm, Monday through Friday unless otherwise approved by the Development Services Division. 2. Commercial, multi-family, new single family and other nonresidential construction activities shall be restricted to the hours between seven o’clock (7:00) a.m. and eight o’clock (8:00) p.m., Monday through Friday. Work on Saturdays shall be restricted to the hours between nine o’clock (9:00) a.m. and eight o’clock (8:00) p.m. No work shall be permitted on Sundays. Development Engineering: (Contact: Huy Hyunh, 425-430-7384, hhuynh@rentonwa.gov) 1. See Attached Development Engineering Memo dated February 26, 2024 Fire Authority: (Contact: Corey Thomas, 425-276-9582, cthomas@rentonrfa.org) 1. None at this time Technical Services: (Contact: Stephanie Rary, 425-430-6592, srary@rentonwa.gov) 1. None at this time Community Services: (Contact: Erica Schmitz, 425-430-6614, eschmitz@rentonwa.gov) 1. None at this time Police: (Contact: Cyndie Parks, 425-430-7521, cparks@rentonwa.gov) 1. See Attached Police Memo Building: (Contact: Rob Shuey, 425-430-7235, rshuey@rentonwa.gov) 1. None at this time EXHIBIT 6DocuSign Envelope ID: 6D919735-4AE7-4A01-A55A-6AEE8BC6E431 DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT M E M O R A N D U M DATE: Feb 26, 2024 TO: Jill Ding, Senior Planner FROM: Huy Huynh, Civil Engineer II SUBJECT: Bindaas Restaurant 811 S 3rd St LUA24-000046 I have reviewed the application for the Bindaas Restaurant located at 811 S 3rd St and have the following comments: EXISTING CONDITIONS The site is a single parcel (7231501820) of approximately 12,000 square feet. The site currently contains a commercial property. The site is fronted S 3rd St in the north, private property to the west, Wells Ave S to the east, and private property to the south. WATER: The proposed development is within the City’s water service area and in the Valley 196 pressure zone. There is an existing 12-inch water main located on S 3rd St (Record drawings: W-036721) that can deliver a maximum flow rate of 5,000 gallons per minute (GPM). There is an existing 12-inch water main located in Wells Ave S that can deliver a maximum flow capacity of 3,500 GPM (see water plan No. W-391101). The static water pressure is approximately 67 psi at ground elevation of 42 feet. There is an existing 1-inch meter (facility ID number LAT-020430) and one existing ¾” meter (facility ID numbers LAT-020433 and LAT-020434) serving the lot on Wells Ave S. SEWER: The proposed development is within the City’s sewer service area. There is an existing 8-inch gravity wastewater main located in Wells Ave S (record drawing S-27221D). There are two existing concrete wastewater service lines located in Wells Ave S. STORM: There is an existing 8-inch concrete surface water main on S 3rd St . STREETS: The proposed development fronts S 3rd St along the North property line. S 3rd St is classified as a Residential Access Street with an existing ROW of approximately 60 feet. The proposed development fronts Wells Ave S along the east property line. Wells Ave S is classified as a Residential Access Street with an existing ROW of approximately 60 feet. DocuSign Envelope ID: 6D919735-4AE7-4A01-A55A-6AEE8BC6E431 Index Ave Townhomes– LUA23-000381 Page 2 of 7 December 6th, 2023 WATER COMMENTS 1. The project is within the City of Renton’s water service area in the Valley 196 pressure zone. For the Tenant Improvement (TI) at 811 S 3rd St, there is an existing 12-inch water main located on S 3rd St (Record drawings: W-036721) that can deliver a maximum flow rate of 5,000 gallons per minute (GPM). There is an existing 12-inch water main located in Wells Ave S that can deliver a maximum flow capacity of 3,500 GPM (see water plan No. W-391101). The static water pressure is approximately 67 psi at ground elevation of 42 feet. There is an existing 1-inch meter (facility ID number MTR-017185) and one existing ¾” meter (facility ID numbers MTR-017185) serving the lot on Wells Ave S. i. A double check valve assembly (DCVA) backflow prevention assembly will be required for the existing and proposed commercial use of the building. The DCVA shall be installed inside the building on the private water supply line before any water fixtures. A plumbing permit will be required for this work. 2. The development is subject to applicable water system development charges and meter installation fees based on the size of the water meters. Current fees can be found in the 2024 Development Fees Document on the City’s website. Fees will be charged based on the rate at the time of Civil Construction Permit issuance. a. If the project will keep using the existing water services and no water system development charges (SDC) or water improvements are required. b. However, if the proposed development requires to upgrade and/or add water services and meters, the development is subject to applicable water system development charges (SDC’s) fee and meter installation fees based on the number and size of the meters for domestic uses. Current fees can be found in the 2024 Development Fees Document on the City’s website. Credit will be applied to the 3/4-inch existing service if abandoned. SEWER COMMENTS 1. Sewer service is provided by the City of Renton. 2. For the Tenant Improvement (TI) at 811 S 3rd St, There is an existing 8-inch gravity wastewater main located in Wells Ave S (record drawing S-27221D). There are two existing concrete wastewater service lines located in Wells Ave S. a. There is no new sewer stub proposed. The existing stub can be CCTV’s and if found acceptable to the wastewater utility, can be used if the size/locations are compatible with the proposed us/building layout. All new sewer stubs shall conform to the standards in RMC 4-6-060 and City of Renton standard details. b. A grease interceptor is required if not currently equipped with one. 3. If the existing sewer service can be reused, no sewer system development charges are applicable. If the domestic water meter size is required to be upsized or additional meters are required as result of the project, applicable SDC fees would be required. Credit would be provided of the existing meter size. STORM DRAINAGE COMMENTS 1. A drainage report complying with the 2022 Renton Surface Water Design Manual (2022 RSWDM) will be required if construction is proposed exterior to the existing building. Based on the City’s DocuSign Envelope ID: 6D919735-4AE7-4A01-A55A-6AEE8BC6E431 Index Ave Townhomes– LUA23-000381 Page 3 of 7 December 6th, 2023 flow control map, the site falls within the City’s Peak Rate Flow Control Standard (Matching Existing Conditions). The site falls within the East Lake Washington-Renton Drainage Basin and Johns Creek sub basin. Refer to Figure 1.1.2.A – Flow chart to determine the type of drainage review required in the RSWM. a. No drainage review will be required since there is no construction proposed exterior to the existing building. TRANSPORTATION/STREET COMMENTS 1. As this project is proposing an interior remodel and no new construction or additions valued at over $175,000, no street frontage improvement or right of way dedication are required per RMC 4-6-060. GENERAL COMMENTS 1. The fees listed are for 2024. The fees that are current at the time of the respective permit issuance will be levied. Please see the City of Renton website for the current fee schedule. DocuSign Envelope ID: 6D919735-4AE7-4A01-A55A-6AEE8BC6E431 Page 1 of 4 PROJECT LUA24-000046 Bindaas Restaurant/Bar/Banquet 811 S. 3rd St., Renton City of Renton Department of Planning / Building / Public Works ENVIRONMENTAL & DEVELOPMENT APPLICATION REVIEW SHEET POLICE RELATED COMMENTS 10 Police Calls for Service Estimated Annually (based on square footage) CONSTRUCTION PHASE To protect materials and equipment it is recommended that all materials and tools be locked up when not in use. Toolboxes and storage containers should be secured with heavy-duty padlocks and kept locked when not in use. The site will need security lighting and any construction trailer should be completely fenced in with portable chain- link fencing. The fence will provide both a physical and psychological barrier to any prospective thief and will demonstrate that this area is private property. Construction trailers should be kept locked when not in use and should also have a heavy-duty deadbolt installed with no less then a 1-1/2” throw when bolted. Any construction material that contains copper should be removed from the construction site at the end of each working day. Glass windows in the trailer should be shatter-resistant. I also recommend the business post appropriate “No Trespassing” signs on the property while it’s under construction. This will aid police in making arrests on the property after hours if suspects are observed vandalizing or stealing building materials. The use of off- duty police officers or private security guards to patrol the site during the hours of darkness is also recommended. A Business Trespass Authorization Agreement, allowing the police to trespass upon your behalf, can be completed and submitted to the Renton Police Department. For a copy of the authorization form, please contact Sandra Havlik at Shavlik@rentonwa.gov or 425-430-7520. COMPLETED BUILDING Access Control Access control is the ability to decide who gets in and out of your business. It’s important to direct all foot and vehicle traffic towards the main entrance of the building. Excess entry doors should be designed so that they automatically lock when closed and only serve as emergency exits. Windows should be designed so that they can’t be used as entry points for people, although some could be equipped to be utilized as emergency exits if needed. DocuSign Envelope ID: 6D919735-4AE7-4A01-A55A-6AEE8BC6E431 Page 2 of 4 Doors/Glass All exterior doors should be made of solid metal or metal over wood, with heavy-duty deadbolt locks, latch guards or pry-resistant cylinders around the locks, and peepholes. All strike plates should have 2-1/2 to 3” wood screws. If glass doors are used, they should be fitted with the hardware described above and additionally be fitted with a layer of security film. Security film can increase the strength of the glass by up to 300%, greatly reducing the likelihood of breaking glass to gain entry. Lighting Lighting is collectively considered to be one of the most important security features. Good lighting has been documented to deter crime and produce a more secure environment. Good lighting also enhances the effectiveness of CCTV systems. All areas of parking and pedestrian travel need to have adequate lighting. This will assist in the deterrent of criminal activity as well as provide safe pedestrian travel for employees and customers. Considerations for adequate pedestrian and parking lot lighting should be in design elements. Lighting selection should adhere to the standards of the Illuminating Engineering Society (IES) as well as Crime Prevention Through Environmental Design (CPTED) standards. Landscaping The “Broken Window Theory” says, “An ordered and clean environment – one which is maintained – sends the signal the area is monitored and that criminal behavior will not be tolerated.” All trees should be trimmed six to eight feet up from the ground. Shrubs should be pruned to no more than three feet tall. This will help eliminate are as of concealment for suspicious persons. Trees and shrubs which are not maintained can cause safety issues. If new landscaping is planned, then it will be in its “infant” stages once the business is completed which would not be an issue within the first few months. However, regular maintenance should be planned, and landscaping monitored to stay within the above-mentioned guidelines. As noted above, landscaping must be well maintained to prevent overgrowth and/or create areas that could be considered unsafe if individuals or criminal activity can go unseen by passerbies or security doing patrols of the area. Territoriality/Signage Territoriality refers to measures that reinforce a message of ownership over the business. The most straight-forward examples of territoriality are signs restricting access, directing customers to the main entry doors and lobby/reception areas, as well as posting the businesses hours of operation. The public needs to be made aware at all times of what space is private and what space is public. Signs and graphics can also assure staff and the public that their safety is being monitored. Likewise, potential perpetrators may be deterred by a notice that they are under surveillance. Proper No Trespassing signs should be posted in conspicuous locations throughout the outside of the buildings (including parking areas) so enforcement action can be taken if needed. Defining clear borders is another step that reinforces territoriality. A low fence or hedge around the edge of the property may not physically stop a trespasser, but it helps identify DocuSign Envelope ID: 6D919735-4AE7-4A01-A55A-6AEE8BC6E431 Page 3 of 4 where public space ends and private space begins. Maintenance further reinforces territoriality. Any unkempt part of the property will soon send a message that no one is particularly concerned about or possessive of that part of the business. If the area remains neglected, it will also seem ideal for misbehavior or loitering. If there is a smoking area provided outside the building, this area needs to be well-lit and monitored often by employees for safety purposes. Additional Recommendations for Restaurants, Bars & Banquet: Since the plans specifically mention that this restaurant will also include a bar area, banquet rental area, and DJ’s and/or live music I am making additional recommendations to consider before and after the business is operational: Main & Bar Entrance The main entrance to the restaurant and bar should be monitored and visible to all employees. For weekends/evenings where live music and/or DJ is present, or the banquet room will be rented, consideration needs to be made as to what size of crowd could attend. I recommend that security personnel be in place at the bar entrance to perform a visual check and run identification checks before being allowed entry into the bar and/or banquet area (if alcohol is being served at the event). If no security is present, then bar staff/servers should check identification to prevent against underage drinking. This also sends a message that you are paying attention to who enters your establishment, and that security and safety is of utmost importance. I recommend cameras be placed at several locations outside of the bar and inside to capture facial recognition as people enter/exit. Cameras can be placed high to capture overall activity, although some should be at eye level for facial recognition. If all cameras are placed too high, it is not hard for those who want to avoid being captured on film to look down and/or wear a hat. Camera surveillance can be a deterrent to crime but also important to law enforcement when solving crime. Any alternative employee entrances should have coded access to prevent trespassing. Exterior doors should be checked routinely to insure they are not being propped open. This restaurant is in the process of permitting for a drive-thru window. If approved and installed, extra security measures need to be considered. Drive thru windows are often vulnerable and can be used as entry points to a business. I recommend a rolling security shutter is installed and mounted on the interior of the opening. This will be a deterrent to would-be criminals considering burglarizing your business through this entry point. Main/Banquet Bar Area The bar should be in a location that allows your staff viewing access throughout the main floor bar, throughout the rest of the restaurant, and street views, if possible, via windows. This visibility allows employees to see who is entering the building, activity happening across the main floor, and outside the windows. The bar area/counter should be open with no obstructions affecting the monitoring of patrons and/or premises. Cash registers should be front facing allowing visibility of patrons while conducting transactions. Floors behind the bar counter, where DocuSign Envelope ID: 6D919735-4AE7-4A01-A55A-6AEE8BC6E431 Page 4 of 4 employees/bartenders/servers stand, should be built on a higher platform then the floor level, to allow them visibility over the heads of their customers to see everything happening on the main floor. Kitchen Area This area should be secure and clearly identified as an “employee only” area. You do not want anyone to wander back there and breach into the “employee only” areas. Signs should be posted that this is an “employee only” area and that a swing bar/gate type structure be added to clearly define the space. This will deter unpermitted persons access to the area where employees may keep their personal items and there is high-dollar inventory, such as liquor, food, equipment, or other supplies that could be stolen. Kitchens can get warm, and employees often prop open back doors to allow air circulation. If doors are left propped open, they could allow a potential security breach which could lead to theft, robbery, or other crimes. DocuSign Envelope ID: 6D919735-4AE7-4A01-A55A-6AEE8BC6E431