Loading...
HomeMy WebLinkAboutR-425007O LO N O W J J LJ m Q I �i 10 (V 0 (V rn +s 3 LJ I Cy) 00 i 0 U z 0 (n z Q m x LLJ i C N i CO i 0 0 0 00 n a Z 0 10' 20' 40' SCALE: 1 "=20' ALL STORM PIPES, STRUCTURES, AND FACILITIES SHALL BE PRIVATELY OWNED AND MAINTAINED UNLESS OTHERWISE NOTED. ® DRAINAGE NOTES 1. CONNECTION FOR ROOF DRAIN CONFIRM DOWNSPOUT LOCATIONS AND TIE-IN POINTS WITH PLUMBING PLANS. 2. TYPE 1 CATCH BASIN. SEE DETAIL 1 /C5.1. 3. CURB CUT. SEE DETAIL 4/C10.3. 4. STORM DRAIN (SD) LINES SHALL BE ADS N-12 UNLESS OTHERWISE NOTED. ALL STORM DRAIN PIPES SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS AND CITY STANDARDS. SEE DETAIL 3/C5.1 FOR CITY STANDARDS. O MODULAR WETLAND MODULAR WETLAND 4'X8' MODEL MWS-L-4-8-V-UG SEE DETAIL 3/C5.2. O PERVIOUS CONCRETE SEE DETAILS 5/C5.1 AND 1/C5.2. Q SOIL AMENDMENT INSTALL IN ALL LANDSCAPE AREAS. SEE DETAIL 2/C5.2. O UTILITY POTHOLE SEE SHEET C9.0 FOR POTHOLING REQUIREMENTS 7-7 11 �11 / 10' WIDE ACCESS ESMT REC NO. 7607260646 RELINQUISH ED. E D 09/28/2023 11 1 REVISED 20' X 5' ACCESS EASEMENT REC NO 20230026000786 PROPOSED 13' X 19 ACCESS EASEME REC NO. 2023092800 L1.0 AIL CORNER COMMERC►A1. N7T26.42"E 1 n ° I / \ N c ° 3 1 N Jcl N 'CL 3 yy �\Z�m SEWER EASEMENT / REC NO. 5253595 1 / LnLn / EL / PAVEMENT SWALE (TYP) 2 10' GAS EASEMENT KC REC NO. 20130411001089 / ° A RIM PER PLAN RIM PER PLAN NEW 8" PIP AND EXPAN KNOCKOUT IE = 26.31 6" CKOUT = 26.31 EX. CB KNOCKOUT ADJUSTMENTS C5.0 SCALE: N.T.S. UTILITY CONFLICT NOTE: THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE 0 1-800-332-2344 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT BARGHAUSEN CONSULTING ENGINEERS, INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. POWER EASEMENT KC REC NO. 9410201209 / I \ 76 LF 8" DI SD 0`0.50 C DRAINAGE PLAN FOR CHICK=PIL=A RENTON SECTION 18, TWP. 23 N., RGE 5 EAST, W. M. CITY OF RENTON, KING COUNTY, STATE OF WASHINGTON .5' NT \. \i 0786 N'. \ 4, h CA co G \ � 3 ♦so 2,� s \ \1 \ 3 A J\ \ \\ \\ \ \ \\ \ Y4 PROP. DRIVE THROUGH (� \ - - - - - - - - - - _ CANOPY PER ARCH. PLANS 61 LF 8" DI SD @ 0.50% ��` G\ CB \ N1 55,75 \1 ' \► ` \ I � _ 1 RD #1 \ iI -19 LF 8" PVC SD 0.50%\ v \ \ \ 10' GAS EASEMENT ` `\ KC \ REC. NO. 20130411001089 RD #2 19 LF 8" PVC SD_ @ 0.50% \ \ RD #3 � � \ CB \ f PROP DRIVE THROUGH` g ` CANOPY PER ARCH. PLANS �" \ s SLOPES & UTILITIES EASEMENT \ � CB \ -�'� PER 20110620001119 \ o a\' s \ ♦ 3 66 LF 8" PVC SD @ 0.50% ' \� \ \ EXISTING CATCH BASIN EXISTING CATCH BASIN (� ` _ \ RIM = 29.26 c ♦ \ Ss \ RIM = 30.61 P00 \ \ EX. IE 8 S (OUT) = 26.31 --� ` 18 1.- EX, IE 12 S (IN) = 25.12 NEW IE 8" NW (IN) = 26.31 `� `. ,-� �;.� NEW IE 12" W (IN) = 25.12 NEW IE 8" N (IN) = 26.31 \ s ♦ 3 a . �� NEW IE 8" N (IN) = 25.12 ` \ SEE DETAIL THIS SHEET. \ ° \\` ♦♦ \� Q EX. IE 12" E (OUT) = 25.12 ADJUST THE EXISTING CATCH d �� ♦♦ o ° m CB BASIN DIRECTION TO \ \ ss USE EXISTING OIL/WATER SEPARATOR: ♦ / ° POWER EASEMENT ` ACCOMMODATE THE v° ` CONNECTIONS AS NEEDED \ 1,000 GAL GREASE INTERCEPTOR \ � 1 S C � \ K� EC. N0. 9410201209 / - s SINGLE VAULT SYSTEM ° SEE DETAIL 3/C8.1 �E RIM = 30.71 sa / fvba2'I ` J NEW IE 12" W (IN) = 25.57 �_- �' \ � : � \ \ CB y`F' NEW IE 12 E (OUT) = 25.57 - 14 LF 12„ PVC SD CAD 0.67% ° 4 \ \ RESET STANDPIPE PER sD - sD F 1 P ° 5O / S°`� (1 \`L� q n " \ \ ` CB - 4 6 L 2 ,VC SD 0 0.50% ° DETAIL /C5.2. , �C o .� m •. CB ` 6 LF 12" PVC SD CAD 1.69% � .. ss./ �• 9\ \ \ \ � sN 3 �\ \ 519 n ;0 \ Cl 4 .'O . \ \ w ° ' .SS• / �. s ° SLOPES & UTILITIES EASEMENT 5KOUT ° sN \\ SS o n . e %\ J a c§ \ \KC REC NO. 20110811001003 \ ° c J SSAIIH S SS \55 ° ° / a° •„ Sp e l a SS \55 ; : n J . .. ° 5° a . • / 4\ C B \ C' a c/ 5v 'l •d 0 / / \�� \ \ NEW 8" PIPE a. 50 / / \ V� AND EXPANDED KNOCKOUT \\` °, °so ° ' a50.a / / / / \\c' Cg o IE = 26.31 15 X 100 SEWER EASEMENT � o,p.. \ , .� REC NO. 9708110700 s �pG ❑2 El \rJ a u ❑a STORM STRUCTURES TABLE CB #1, TYPE 1, W/STANDARD GRATE LAT: 47.4790237• LONG:-122.2172067• RIM = 28.79 IE=26.62 (8" S) CB #2, TYPE 1, W/STANDARD GRATE LAT: 47.4788825• LONG:-122.2174684• RIM = 28.76 IE=26.69 (8" E) MWS, MWS-L-4-8-V-UG LAT: 47.4786680• LONG:-122.2169592• RIM = 30.80 IE=25.46 (12" W) IE=25.21 (12" E) RD #1, W/TRAFFIC-RATED LID LAT: 47.4788990• LONG:-122.2170429• RIM = 29.47 IE=25.64 (8" S) RD #2, W/TRAFFIC-RATED LID LAT: 47.4788993• LONG:-122.2170160• RIM = 29.67 IE=25.55 (8" N) IE=25.55 (8" S) RD #3, W/TRAFFIC-RATED LID LAT: 47.4788508• LONG:-122.2169878• RIM = 29.87 IE=25.45 (8" N) IE=25.45 (8" S) , 4 Know what's below. 10 GAS EASEMENT PORTION OF • - - TED-40-4063 TO REMAIN (TYP IMPROVEMENTS FROMCal I before you dig. Dial 811 OF STORM WITHIN PROPERTY) \ Ilk I�hq�.'. I ►� I��I��L�'�r� �Ar kmilgyp° °<��i�Io� ;'�j��i��� • � p /�� %-. SURFACE WATER UTILITY DEVELOPMENT ENGINEERING ���,�•,, pp°�i\ '�7�G;/',',�, 1 . - / ('jR" • / / 'DF.NTO? nA / � �`'��'� ice• .� Bar hausen g Consulting Engineers, Inc. 18215 72nd Avenue South Kent, WA98032 425.251.6222 barghausen.com SURVEYED: RLH SCALE: � ^/ ' =20 VERTICDATE: HORIZONTAL: NADD79S%1991 � UiR CITY OF RENT 0 N Planning/Building/Public Works Dept. O o DRAINAGE PLAN 0 D FOR CHICK-FIL-A RENTON dd 375 RAINIER AVE S RENTON, WA 98055 STORE NO.:04249 03/29/2023 DESIGNED: ADB FIELDBOOK: PAGE: MMM DRAWN:ONE INCH DRAWING N0: C5.0 CHECKED: is l� AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY N0. REVISION BY DATE APPR APPROVED: ADB SHEET: 7 OF: 20 N T O O N 1 u H H T N Q J