ILLUMINATION PLAN
FOR
CHICK=FIL=A RENTON
SECTION 18, TWP. 23 N., RGE 5 EAST, W. M.
CITY OF RENTON, KING COUNTY, STATE OF WASHINGTON
ILLUMINATION GENERAL NOTES
1. THE LOCATION OF ALL CONDUIT, JUNCTION BOXES, AND CABINETS SHOWN ON THIS PLAN ARE APPROXIMATE
ONLY. FINAL LOCATION SHALL BE DETERMINED BY THE CONTRACTOR AND CONFIRMED IN THE FIELD BY THE
ENGINEER.
2. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, CITY OF RENTON STANDARDS AND WSDOT
STANDARDS AND SPECIFICATIONS, CURRENT EDITION.
J. THE LOCATIONS OF FEATURES SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE
CONTRACTOR AS NECESSARY.
4. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE CITY OF RENTON FOR MATERIALS APPROVAL AT THE
EARLIEST POSSIBLE DATE.
5. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT
ALL PERTINENT UTILITY AGENCIES 48 HOURS BEFORE COMMENCING WORK, AND SHALL COORDINATE WITH
AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL
NOTIFY THE AFFECTED UTILITY COMPANY AND THE CITY OF RENTON IMMEDIATELY UPON DAMAGE.
7. POLE FOUNDATIONS SHALL NOT BE EXCAVATED AND POURED BEFORE POLE LOCATIONS ARE APPROVED BY THE
ENGINEER.
8. ELECTRICAL CONTRACTOR TO CONTACT CITY CONSTRUCTION INSPECTOR FOR INSPECTION OF POLE FOUNDATIONS,
BASE BOLTS, AND CABINET FOUNDATION.
9. CONTRACTOR TO CONTACT CITY ELECTRICAL INSPECTOR FOR UNDERGROUND/ROUGH—IN INSPECTION.
10. CONTRACTOR TO CONTACT TRANSPORTATION MAINTENANCE MANAGER, ERIC CUTSHALL 425-430-7423, FOR
STREET LIGHTING COMPLIANCE TO STANDARDS INSPECTION PRIOR TO ENERGIZING.
11. FOLLOWING THE TRANSPORTATION MAINTENANCE INSPECTION, THE CONTRACTOR SHOULD CONTACT THE CITY
ELECTRICAL INSPECTOR FOR SERVICE INSPECTION.
12. FOLLOWING THE SERVICE INSPECTION FROM CITY ELECTRICAL INSPECTOR, ELECTRICAL CONTRACTOR SHALL
SUBMIT APPLICATION TO PSE TO ENERGIZE THE STREET LIGHTING.
13. ELECTRICAL CONTRACTOR SHOULD CONTACT THE CITY ELECTRICAL INSPECTOR FOR FINAL INSPECTION AFTER
STREET LIGHTING HAS BEEN ENERGIZED.
14. CONTRACTOR SHALL POTHOLE ALL POLE LOCATIONS TO CONFIRM THAT THERE ARE NO UNDERGROUND
CONFLICTS. IF A CONFLICT IS DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO
FOUNDATION INSTALLATION.
15. THE CONTRACTOR SHALL CONFIRM THAT THE APPROPRIATE MINIMUM CIRCUMFERENTIAL CLEARANCE IS PROVIDED
BETWEEN LUMINAIRE POLES AND OVERHEAD POWER LINES. IF A CONFLICT IS DISCOVERED, THE CONTRACTOR
SHALL NOTIFY THE ENGINEER PRIOR TO FOUNDATION INSTALLATION.
ILLUMINATION CONSTRUCTION NOTES
D
CONSTRUCT NEW FOUNDATION PER CITY OF RENTON STANDARD PLANS 117.1 AND 117.1A. NEW FOUNDATION
SHALL MATCH EXISTING FOUNDATION SIZE AND SHAPE. CONTRACTOR SHALL VERIFY BOLT PATTERN PRIOR TO
POURING FOUNDATION. RELOCATE EXISTING LUMINAIRE POLE AND LUMINAIRE TO NEW FOUNDATION PER
ILLUMINATION POLE SCHEDULE, THIS SHEET, AND PER CITY OF RENTON STANDARD PLANS 117.1, 119 & J013.
REMOVE EXISTING FOUNDATION TO A MINIMUM 5' BELOW SURFACE GRADE. FILL AND COMPACT VOID.
(�)EXISTING JUNCTION BOX TO REMAIN. PULL EXISTING CONDUCTORS FOR EXISTING LUMINAIRE POLE BEING
RELOCATED BACK TO EXISTING JUNCTION BOX AND PULL THROUGH NEW CONDUIT TO RELOCATED POLE
LOCATION. IF SUFFICIENT SLACK IS NOT AVAILABLE, CONTRACTOR SHALL REMOVE EXISTING CONDUCTORS FOR
EXISTING LUMINAIRE POLE BEING RELOCATED AND SPLICE NEW CONDUCTORS WITH CITY APPROVED SPLICE KIT
AND PULL THROUGH NEW CONDUIT TO RELOCATED POLE.
O3 EXISTING LUMINAIRE POLE TO REMAIN.
ILLUMINATION WIRING SCHEDULE
RACEWAY
CONDUIT
SIZE
ILLUM.
#8
EQUIP.
GRND.
NO.
1
NEW 2" SCH80 PVC
2
1
* EQUIPMENT GROUND SIZE SHALL BE EQUAL TO OR
LARGER THAN THE LARGEST WIRE SIZE IN THE
CONDUIT
ILLUMINATION POLE SCHEDULE
LUM.
POLE ID
*OFFSET
*
**
**
MOUNT.
ARM
WATTAGE
INITIAL
FIXTURE MODEL
POLE NO.
NUMBER
STREET
STATION
LATITUDE
LONGITUDE
HEIGHT
LENGTH
VOLTAGESERVICE/
CIRCUIT
ITYPE
LUMENS
(OR APPROVED EQUAL)
BASE
COMMENT
O
EX 2446C 135
RAINIER AVE S
1 1 +00.0
60.0' RT
EX 35'
EX 12'
EX 240
EX
EX 135W
EX
EX PHILIPS LUMEC DOMUS
FIXED
MATCH EXISTING FOUNDATION SIZE.
LED
13,544
DMS50-135W80LED4K—R—LE3F
* STATIONS/OFFSETS ARE APPROXIMATE. CONTRACTOR SHALL CONFIRM ADJUSTMENTS WITH CITY INSPECTOR PRIOR TO IMPLEMENTING.
** POLE LATITUDE AND LONGITUDE NUMBERS SHALL BE PROVIDED BY CONTRACTOR FOR INCORPORATION INTO AS —BUILT PLANS.
Transportation Engineering NorthWest
Transportation Planning I Design I Traffic Impact & Operations
1400 SE 8th St, Suite 200, Bellevue, WA 98004 1 Office (425) 889-674
Project Contact: Trevin Roletto, P.E. NO.
Phone: 425-250-0583
INSV/6yto] II
SURVEYED:
DESIGNED: KEW
DRAWN: LAB/DVB
CHECKED:
TDR
BY DATE APPR I APPROVED: TDR
SCALE:
AS NOTED
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL NAD 1983/1991
PROJECT #: 2023—
>0/>3/2023
CITY 0E
RENTON
Planning/Building/Public Works Dept.
15 60
0 30 90
SCALE IN FEET
ILLUMINATION LEGEND
EX
NEW/RELOCATED
DESCRIPTION
®
JUNCTION BOX TYPE 1
STREET LUMINAIRE POLE
PEDESTRIAN LUMINAIRE POLE
— — —
— — —
CONDUIT/CONDUCTOR
OCONSTRUCTION
NOTE
O
LUMINAIRE POLE NUMBER
AWIRE
NOTE
0 Know what's b@IOW.
Call before you dig.
1 Dial 811
i
A-425018
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
L
ANSPORTATION OPERATION DEVELOPMENT ENGINEERING
cbarnes 11 /29/2023 yqi 12/05/2023W1
DU ILLUMINATION PLAN
0 D FOR
CHICK—FIL—A RENTON
�D ® 375 RAINIER AVE S RENTON, WA 98055
N5,,-A-aRRA STORE NO.:04249
DATE:
10/13/2023
FIELDBOOK:
PAGE:
-01
SHEET: OF: 2 2
21
N
T
C)
co
o
N
��
T
N
Q
J
H
H