HomeMy WebLinkAboutT-410901C�
0
0
0
D
V J
O
Nt
T-
O
rr
0
O
W
D
0
0
C
U
W
0
C
S
LEGAL DESCRIPTION
THE NORTH 2 z ACRES QE THE SOUTH EAST QUARTER OF THE
SOUTHEAST QUARTER OF NORTHWEST QUARTER IN SECTION 5,
TOWNSHIP 22 NORTH, RANGE 5 EAST 5 EAST, W.M IN KING COUNTY
WASHINGTON.
EXCEPT THE EAST 30 FEET FOR ROAD.
��� [�' i��'J�ATJ, � � i I'i y [!7 i � �]'i/1//p���'�] �� [�ZOI � i �G�1�'J \► UJ'�►i�l�l � i I'J�ti�I i
AND ALSO EXCEPT THAT PORTION THERE OF CONVEYED TO THE STATE
QE WASHINGTON FOR STATE ROUTE 515 BY DEED RECORDED UNDER
RECORDING NO 8906291184:
SITUATED IN THE CITY QE RENTON, COUNTY OF KING, STATE QE
WASHINGTON
CITC 1'IATA
TAX PARCEL NO: 052205-9078
SITE ADDRESS: #19805 108TH AVE SE RENTON,
WA 98055
TOTAL SITE AREA: 97,174 SE
ZONING: R4
DocuSign Envelope ID: 5D308AIA-204D-48E8-BB23-8A2834BB565E
PAINT SPECIFICATIONS:
ALL ALUMINUM LUMINAIRE AND POLE
RELATED PARTS SHALL BE FACTORY
PRIMED AND POWDER COATED.
FINISH COLOR. RAL 9005TX "JET BLACK"
18-1/4"
PRESTIGE SERIES (C118T4 LED
WI
POST -TOP LUMINAIRE (WATTAGE
PER PLANS, 4,000K COT, 120-277V
UNIVERSAL DRIVER, WITH VS3AR
_ .� RIBBED ACRYLIC LENS) BY CYCLONE
M (� (OR APPROVED EQUAL). DRIVER
I SHALL BE INTEGRAL TO THE
FIXTURE.
TERMINAL BLOCK LOCATED IN THE
FIXTURE
STREET LIGHT STANDARD DECAL
NUMBERING PER STD PLAN 121
14'-0" FLUTED SHAPE, 5" DIAMETER,
STRAIGHT ALUMINUM POLE
(PD15-14-BD46-RAL9005TX-TN43)
BY CYCLONE (OR APPROVED EQUAL)
INSTALL GROUT.
PROVIDE 112" DIA DRAIN
TUBE THROUGH GROUT.
3/4" CHAMFER -�
6" HIGH FOUNDATION CAP
2 x5' HANDHOLE
(4) OVAL SLOTS
,0
BASE PLATE DETAIL
24" 8 - #5 BARS,
2" CONDUIT UNLESS EVENLY SPACED
STATED OTHERWISE ON�
PLANS CENTER CONDUIT
IN FOUNDATION
BOLT CIRCLE (DIA PER.
ANCHOR BOLT BASE PLATE DETAIL,
THIS SHEET)
k4 HOOPS @ 12"
FOUNDATION SECTION
2" CONDUIT UNLESS GROUND POLE TO
STATED OTHERWISE ONFOUNDATION
PLANS
6" FOUNDATION CAP -N \ F
3/4" CHAMFER (TYP)
EXTEND THE CONDUIT
6" MIN BEYOND
FOUNDATION OR THE
CONTROLLED DENSITY
BACKFILL
#4 HOOPS @ 12"
8 - #5 BARS,
EVENLY SPACED
2 1/2" CLR
3" M N. BOLT
PROJECTION j
MME
11■ilion
I,I,It
Il1��I!
!INN
INN
I■■
I■■
24'
FOUNDATION DETAIL
.� 7/8" DIA HOLE
�a z
(TYP)
�•. 2• 1/4" STEEL PLATE
BOLT CIRCLE (DIA
PER BASE PLATE
DECORATIVE ALUMINUM CLAMSHELL DETAIL, THIS SHEET)
BASE COVER BD46 BY CYCLONE ANCHOR BOLT -EMPLATE DETAIL
(OR APPROVED EQUAL) POLE BASE DETAIL
TOP OF FOUNDATION
ANCHOR BOLT, 4 TOTAL,
3/4" DIA (TYP)
3/4" HEX NUTS, STEEL (6
REQ'D PER ANCHOR BOLT),
FLAT WASHERS (6 REO'D PER
ANCHOR BOLT)
ANCHOR BOLT ASSEMBLY DETAIL
FOUNDATION DETAILS
POLE BASE PER
DETAIL, THIS
SHEET
T ` FOUNDATION PER DETAILS,
THIS SHEET
POLE ELEVATION
NOTE: SONATUBE SHALL NOT BE ALLOWED
FOR FOUNDATION CONSTRUCTION
G�tY o NEIGHBORHOOD STREET STD. PLAN - 116.1
PUBLIC WORKS PEDESTRIAN LUMINAIRE A ROVED:
DEPARTMENT FIXTURE AND POLE DETAILS GAZ 3/13/2019 I :1
DATE
ELEVATION - DECORATIVE POST TOP
WIRING SCHEDULE
X CONDUIT RUN
�j
0
# OF CONDUITS
AND SIZE
CONDUCTORS
CIRCUIT No.
1
2" PVC (SCH. 40)
PS UTILITY POWER
N/A
2
2 PVC (SCH. 40)
248, 1#8GREEN (BOND)
3#14 PHOTOCELL
A
3
2" PVC (SCH. 40)
2#8, 1#8 GREEN (BOND)
A
4
2" PVC (SCH. 40)
248, 148 GREEN (BOND)
A
5
2" PVC (SCH. 40)
248, 148 GREEN (BOND)
A
6
2" PVC (SCH. 40)
2#8, 1#8 GREEN (BOND)
A
7
2" PVC (SCH. 40)
2#8, 1#8 GREEN (BOND)
A
8
2" PVC (SCH. 40)
248, 148 GREEN (BOND)
B
9
2" PVC (SCH. 40)
248,148 GREEN (BOND)
B
10
2" PVC (SCH. 40)
2#8, 1#8 GREEN (BOND)
B
11
2" PVC (SCH. 40)
PULL STRING (EMPTY)
N/A
12
2" PVC (SCH. 40)
PULL STRING (EMPTY)
N/A
CONDUIT AND WIRING SCHEDULE
LUM. No.
POLE ID. No. **
CIRCUIT No.
LOCATION
GPS COORDINATES *
OFFSET (FEET)
FROM BACK OF
SIDEWALK
LED LAMP
WATTAGE
MOUNTING
HGT. (FT)
STANDARD
PLAN #
1
A
0+17
10'-6"
44
15
116.1
2
A
1+32.5
10'-6"
44
15
116.1
3
A
2+36.5
10'-6"
44
15
116.1
4
A
3+50.5
10'-611
44
15
116.1
5
A
4+64.5
10'-6"
44
15
116.1
6
A
5+80
10'-611
44
15
116.1
7
B
10+87 (106AVE S.E.)
10'-6"
44
15
116.1
8
B
9+92 (106AVE S.E.)
10'-611
44
15
116.1
* - Contractor to record GPS coordinate of pole base at installation to update on record drawings
**- City will provide contractor Pole ID No.s to put on ID Tags at time of construction
LUMINAIRE SCHEDULE
ARY
w
�
�
L
W
W
_
UL
U_
0
HYDRANT
r
U
U
-4-
PLAN SCALE. 1 "=50'
SURVEY BENCHMARK
CITY OF RENTON BM 1852, BRASS DISC IN CONC SI NE 4TH ST AND 1 48TH AVE
SE. PUBLISHED 138.614 METERS NAVD 88 454.769 FEET
CITY OF RENTON BM 2110 1/8" BRASS PIN IN 3" CONIC MON IN CASE AT THE
SI OF SE 1 76TH ST AND 1 1 6TH AVE SE PUB ELEV = 448.162 NAVD88
SURVEY
CENTREPOINTE CONSULTANTS 14209 29TH ST E #105
SUMNER, WA 98390 PHONE: (253) 987-7859
CONSULTANT
MAINLAND ENGINEERING DESIGN CORPORATION
UNIT 206 8363 128TH STREET
SURREY, B.C. V3W 4G1
TEL: 604 543 8044 FAX: 604 543 8104
(� ()
EMAIL: CIVIL(4VXNLANDENG.COM
AIL
SURVEYED:
SURVEYED
SCALE:
1 "50'
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATUM
DESIGNED:
RM
3.
ISSUED FOR REVIEW
SGC
2022/12/02
AB
DRAWN.
MK
I ONE INCH I
2.
ISSUED FOR REVIEW
SGC
2021 /04/14
AB
1.
ISSUED FOR REVIEW
MK
2020/06/19
AB
OHEOKE°: ER
AT FULL S CALE
IF NOT ONE INCH
SCALE AccoRINGI_v
D
N0.
REVISION
BY
DATE
APPR
APPROVED:
AB
2023-03-15
CALL- 48 HOURS
BEFORE YOUR
D C CALL 811
•
MY OF
'D RENTON
Planning/Building/Public Works Dept.
�--
VICINITY MAP
1 " 1 000'
CONSTRUCTION NOTES:
1. ALL LUMINAIRES SHALL BE SUPPLIED AND INSTALLED TO SUIT THE
CURRENT EDITION OF THE CITY OF RENTON PUBLIC WORKS
DEPARTMENT CONSTRUCTION STANDARDS AND GENERAL_ NOTES AS
PER STD. PLAN - 135.
2. LUMINAIRES SHALL BE WIRED TO SUIT STD. PLAN 119.
3. DECORATIVE LUMINAIRES AND BASES SHALL SUIT STD. PLAN 116.1
4. CONTRACTOR SHALL REFER TO STD. PLAN 120 FOR LUMINAIRE
CONCRETE PAD/SIDEWALK AND JUNCTION BOX CONCRETE PAD
DETAIL.
5. ALL STREET LIGHTS SHALL BE SUPPLIED WITH A DECAL NUMBER
TO SUIT STD. PLAN 121.
6. THE PROPOSED SERVICE CABINET SHALL BE SUPPLIED AND
NSTALLED TO SUIT STD. PLAN 122.1 AND 122.2.
7. THE CONTRACTOR SHALL INSTALL THE LUMINAIRE POLE AND
JUNCTION BOX TO SUIT STD. PLAN 124 FOR TOP DETAIL WHERE
LUMINAIRE POLE IS IN -FRONT OF THE SIDEWALK.
8. THE CONTRACTOR SHALL SUPPLY AND INSTALL A SERVICE CABINET
CONCRETE FOUNDATION TO SUIT STD. PLAN 126.1 AND 126.2.
LIGHTING LEGEND
[4-LIGHT POLE #
PROPOSED 15 FOOT DECORATIVE POST TOP, CYCLONE LIGHTING PRESTIGE CY18T4C
' 4K COLOUR, TYPE II DIST. 44W LED C/W BLACK POWDER COAT PAINTED PD14 POLE, BD43
DECORATIVE BASE
1 # OF 2" PVC CONDUITS
�4 CONDUIT SEGMENT #
2 #6 TW75 Feeders and 1 #8 TW75 ( Green ) Ground in 50mm PVC Conduit
-C.O.- 2" PVC Conduit only
D.S. 2" PVC U/G Dip Service 3 #2 RWU90 Feeders
T❑ Service Cabinet ( Voltage 120 / 240 )
Service Main Breaker Size 100 Amps.
Service on or from Utility Power Pole ( Voltage 120 / 240
R Streetlight on Red Phase Conductor
B Streetlight on Black Phase Conductor
ROADWAY LIGHTING DESIGN CRITERIA
PER: (CITY BYLAW)
ROADWAY (NAME)
PUBLIC ROAD
ROAD CLASSIFICATION
RESIDENTIAL (TERTIARY)
PEDESTRIAN CONFLICT
LOW
ILLUMINANCE RECOMMEND/DELIVERED
0.3Fc/0.53Fc
UNIFORMITY RECOMMENDED/DELIVERED
6.0:1 / 3.5:1
SIDEWALK ILLUM. RECOMMENDED/DELIVERED
0.3Fc/0.33Fc
LIGHT LOSS FACTOR
0.8
SPACING (STAGGERED)
114' SINGLE SIDED (MAX)
EQUIPMENT:
FIXTURE TYPE: LED I WATTAGE:44W MTG. HEIGHT: 15' DIST TYPE: 3M
IES FILE: TYPE III, MED, BUG RATING: 131 - UO - G1 MODEL: I CYCLONE CY18T4C
NFORMAPON SHOWN ON THIS DRAWING REGARDING EXISTING UTILITIES
IS COMPILED FROM DIVERSE SOURCES, AND MAY NOT BE COMPLETE
OR ACCURATE. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL
EXPOSE AND CONFIRM THE LOCATIONS AND ELEVATIONS OF ALL EXISTING
UTILITIES, AND ADVISE THE ENGINEER QE ANY POTENTIAL CONFLICTS.
T-410901
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING Q
TRANSPORTATION OPERATION
Michael Sippo 03/30/2023%,�#cbarnes 03/30/20231
'-
MADUENO SHORT PEAT
19805 108TH AVE SE, RENTON
STREET LIGHTING PLAN
0
ICE
u /
O
O
0
U
<
O
O
0
0
0
0
�Z
C
n
0
Z
0
W
DATE:
2022/12/02 0
FIELDBOOK:
PAGE:
WA 98055 DRAWING NO:
17
SHEET:
17OF42