Loading...
HomeMy WebLinkAboutLUA-06-133_Report 1;;.;::::.; .............. "' .. -§ i § ' ~i~~!:~i;SU!=~~ I ! I I ' i i h 8 );lt,!t"'~-o"''"""''" .. ', ! i ' ' i"'l'"ll,"" 1,1.. ...... "'"'i ! ' ' - ' 0 - 1-'~ • il ~· a • ' -'~ ' i i I ' I ll l '6 ! ~--,---------~---. --------- I~ 1;' 1~1 J " .--;:;-_.-- ~· ~~ ~ --·---~ ------!c.~--~r--_-,-_...-.. ~-· 0 ~ ::: 0 a v . ~ ~ ' ~ ; ~ ' ' e BREMERTON A Vf. TOWNHOMES 2S LCTS PRELIMINARY PLAT MAP .J.JO .t-.J?O i3RE MHlrON A i,c, NE 1111m '!· ~ p,:m I p !"i , ,It i~ ; ! - Ii I a ~ ~ • § ~ § e ~ ~ 0 > • 1 ! 8 0 ' . " ~ I I !' ,, ,, '"iil ,, I l ! -.,.,..1:wt-- ,.. .. ... )> -u 0 ;u =J 0 z ~ () =J 0 z ;~~ ; c---1-_-____ .t_ ' --• • ~ f-"-"-'-- ;i ~--~--.-+---c:~·:~·~- 1 ---=·· JAEGER ENGINEERING -i 9419 So<Jth 204!~ Place Xenl, WA 980.JI -~ No. (25J) 115!J-09J4 (a,, No. (25J) 850-0155 i ' A PORTION of the N.E. 1/4 & N.W. 1/4, SECTION 15, TOWNSHIP 23 N., RANGE 5 E., W.M. t:::.~::as::;-.:• I '. I l d -~ I llGCH~AHL Bl~DING t ~ u1111S SITE PLA~ I! !~ ..,_7,-r-Zi:~,-, : ~\ :ii '··11, ·;. :_'.l'0 _ ~-.:.----: --~ --_ .-:·/ ;.-• ..r I'~ 11:)t~--o---<>--r:,,-.,---0--=<b-,,, ~~-"·:; W ••---. I ~ ,.,,c i :-k11 ·· 1 --:, w:,;:.;; ~-;.,.,._~_ , rr:;~ :111-,,'.~ -~ ,: · J · ~' ••ll,11: i .""'J ""·.L 1· ']' 11 11 ' ~II , 1-'l'frlil f..,. I .1&· • : I 11 I f l,e··-•·l!Nl'f-· ~- I~ -;,.._.., , ·. . . ~111 j : ; .;·,:_)} ~.l: ~--~--~ __ __,;.-,,£ r, ., ~ 3 '' CT!fl~Jii ~~~ ~1-~~';f 11: ~' ;§!·\ \\' ; Ii (i ;: s~ _-_,o ' 11:\ , ,· ~s.'\\ ,. i y..\'vv I .1 II '"· I ' .... /cl l,-1 ,. ,, i 1· " ,I ,,_,",.,.. 1: L f 1; CLS,>lt<G ·'"'" I ,1._1,..-1 + ! , •.• ':"f''·-· ,1 r·· 1. / 'i',;,::--1-k ,""------~·,·-~--L.. __ . I I ' '•"; I ' I /-.., --~ 70f'Ol,RAPl<Y A.HO -..,VMIY 51.l'l'CY In'; f entre :WO! ~lh ''"""' Soulh ....... , .. , .. ~ - -o-Pointe l™I UI-LloOL Surveying I I I, c:c_ I I 11 'I ' •i·CilCli} 1: ',. 'I "-"'/ -· I .. ,. .rj :~---__ · -~ r--•.;;,, "<" I! \, JI 1: ,, ii I GRAPHIC SCALE 'k.. w· i 1 .:..."'~ 1 ft ~- T LEGEND EXISTING TREES TREES TO BE REMOVED *··,, CLEARING LIMITS "PO"CSEC.: CO'l lUlJR --,:,---- ~XIST -~c roN IOU..: PRELl!.I GRADING QUANTITIES FILL 4000 CY CUT 500 CY ' 1.FlEVP{J<CllY C, z ll'. w I , wo::;~~ Zs2 S4 of";~ z5; ~~ wai~ '; et::~-:~! w; if~ C, w <( , 8~ 12 ; ~~ ~~ 2 ttl! l,j ~ ~i ::::;; _, :::;: "( "~ '>11 :i:! > a ~ ~~ >----~ ~"1! a ~~ I &i k I; 11i ~ ~~.~ o~ oi!i'-- ,~ o.:"~ i!~ !J I"' -'-"""-,-.;\()· ,......¥_____,;,__ -.IY___,l,,W__ -· _J__ • _J__ A PORTION of the N.E. 1/4 & N.W. 1/4, SECTION 15, TOWNSHIP 23 N., RANGE 5 E., W.M. ~HNl>.HL BINDING I 'I ' I oo~ s,1_e;-_.:,;'_, !i!!,i'T;:~;-,;' : :+ la:[ . . . . ~ . =· ---_:-:··: l ·· ,.\ .,:,i"f"·I ~'~ -~.:_---=::: .. -_ --JJ .,.. ',!, \!, ,: • ~---T . . . --- .,.,, ... 1,.;f l .; I. ~" -:,·:-1 ~ -f'°:'""'-~"'"-'~-• r,~·:ct:[al;"::' ~ .f:J; !~tr I I I ,.\ I l' 1 1 1,, s '. ,.. I ·_.:_I 25_ ~ ·-+--n-, . 111 ~ I 1., j . -H l ,:ir 11 ·1 i '·• ,· 11 I ·1·: ' . ~~~c:-~0):,:-ftJ _ --------;.~-,-..:_. -ti ,.,J· NE 3co c:· .. -•, I~ ''II I I I< 1;'1 -----~ !.j ~I , I --. ;e:;::;:::_:: '• 1 \ ·1 ~t I .• '[ ,1 I I I 9--< I• I 0 e,O l-1,I """ JI 'I .. \\S 11:1 I :·· <}-'<.:; I' I '. /· :~ ? \: : , / 11 l11 ,•I I , I 'I I I I 'i!'.:c 'tl J_:: __ l._ ,, ... Ir t I I :: -~- I I' --I I ,1 ,;1cj[1 i ,) I ;;-• "'j . ·<\ ·1 r,e;;:;· f~; '°;~.~~~~ 1-i i: _ _ Pointe . · ; 11 , .. .,,. Surveymg "' .:' "': ·" · 4'2 "o 408 405 404 402 400 398 h~~,...,-··-.. ~-:~.~;;:,,: .!. "" >U SC'OER PIPESJJ1C8" P'«: >U ""1ERP1PCSAA!:8"0IICT.IROO<. >U OR/JN4GE PW'ES ARC ll" Cl'[)> > " 1J ''l •~,oo ~=:l ,.,,.cr.rJ..'m~ ~TV:Ci. ""2'::I ,':,.,"--' w < ~ • z V' / ~-- IJ" CfT-~lt STOftM I" t~SO<[HT Ta DIJWJ..L A'IE: N£ 1~' "1J8UC WA't[R E-',.'lEl,l[Nl ,. w,,.R w ... C°""[C~<;fl JO ,UfUO'E ,. '"'" l l G-flAPH!C SCALI, :ao I " .. "--~ , ~:::)~ - / ._, C NITR ;,"' foe-•· IEXISTI '" ,o·tc -. •; '"'·~ ~~,'.["<"' '"""''" t $ " .....i.:_f.-/~ -Lo, o,·-·-" __ ' 1' 1 .-=, '" CMCRl:lf. ""~' ~ I, C<"'IJ '* wrir,, ~ -..if·,~,:.-',a -::.~:-:C,~:~C j~~--~,._,,.j,~!~r I ·~ ;i',,':, i;,;f"C"' o:,•,,xrr r..., cr,,,,p•_ [)["PO< a,.~,..,. <SPH'1f , • ..,¥ a,.,.., l»P"' /.l'U""U "<JRI-M.lffl, ~ ,. "'" WUP7 <JfP7" Ci',JSJ<[[l S,JPF<ONC 8AS[ C0,1"S£ GRA...-, ~ASr (<HSS 'El") MA> flF </r(A}jf/ffJ PFNf!ll,G srn CCl'iOlfllW.< TYP. IN TE:RIOR PLA T ROAD "()T fO <C,(f DRAINAGE DETENTION: VAULT LEVEL 2 DETETION STANDARD SUBSURFACE CONC. VAULT VAULT DIMENSIONS: 88" x 42' x 7.0' DEEP TOP LIO ELEV: 406.0 DESIGN 50 YR. WATER LEVEL: 404.5 BOTTOM WATER LEVEL/OUTLET .397.5 VOLUME PROVIDED: 25872 CF VOLUME REQUIRED: 25620 CF WATER QUALITY: WETVAUc T WETVAJL T ::H:L.:•1/1 Lll 11:_N TON '.o IOl'<AGI:_ TO~ WETVAJL T ~-EV 397 5 JOF·:::M W[-PO'srJ :,_r-v: 79."\.5 VO_I.IMI:_ P~OVIDlD /.592 Cf VO. UMr RCOUIRF(} 676CJ er 1'1:~nCAL CIJ/III Vll'i/l.JL-)IMC..'JSIOk>: 88', 21' x 4.0' DEEi""' 'i "' ; ,.~ 4\0 ' .l 408 1, ~>~ 405 404 ~-------s: 402 " t-· --' ". 400 -----.,, -___ J_ __ , ___ I_ I 398 1+00 2+00 .3+00 4+00 PROFILE -INJf,RJ;J,f,~. l,,OOP ROAD 1/ERT: 1· • ,· (.'.) z fl'.. ' w.L~~ W<i.~ I 'T' ~~~!~ C) "'..: ~ ~ Z:S'li:'"":! w~t~ i cr;"'J& W• (.'.) w .: ' e~ ~ ~ :~ I 2 ~ t: ~· ~ §~S "'( ~ ~~ >: -~ -;J?i. 0: i2; ~ ~~ I iii ~ §Q .~ ~vi ~i~ ~~ ~lj "~ ~~: ~" '' ~ ' "~ I= 1" -¥l ~·~......iol,L_ --~ -_J___ • _J___ """,_,.,.,..,.._.,,.,, ___ ""_"'~ -wn;,.,,...,.,,. -~,-.- ' ' ' ' ' " I I ' l i i i i i 1 1 i ii ' ' ' I ]~ ' I ; f!! n •p EEm ::.~~.:~.:~.:.::'"t9§i.101 !iEB . ' N -;" ! ! • SEATTLE REDEVELOPMENT, LL.C. !I irn ' ' ' ·-w., w ••• ,,,, N :;; , ' ' :i BREMERTON TOWNHOMES ;;::. -'" :::: ·,~ I "*"'·"mdvil.CQm l 'i ~:.:...'":;,r.""' ..., . ..,.., ... I ,,_,.,_.., I ' ... cttr ~ RD<TONPREUh.41~ LANOSCAPE PLAN DETAILS & NOTES WAS~l~GTON I "'°""'"°.......-, ......... ,.,.,,,~,~ ' " 0 ~D 0 ~ -a ~o ~ " V> =; m )> !; SITE PLAN 8 AlOO "'"'·"" -""'- ' " ,i I li 1 , I BREMERTON AVENUE TOWNHOU\~,i>, 530 8RO,;:RTON A.'IE~U[ ~E Renton, Wt, t rCCL DRISCOLL ARCHITECTS '~-'--~ .. -« -·- ., ....... , •• ~h.oo~ 115 Sell S1reot•S~a1tl~ WI>. 98121 206•441 ·7705 o 206•441 •5.373 (rax) )> N 0 0 CD C ' g z Cl 0 I ' m < m ' CD c· ' g Zs Cl ' 9' " ' m < m ' CD C ' g z. Cl )> ' m < m ' l~"xl I r I ' . ~I~ , r I , 0 > ·" ~ C ~~; ~= JO PLANS: UNIT A. UNITS B to F UNITS G to H , I m < m 1' "' 330 BREMERTON 1.0611, A\llt1Jl R~·1k·1. WA ' ~ m 1' w -\i:?'"'""' :,.,Y""ll'.l ,,J::noi~,,."' DRISCOLL ARCHITECTS • •·••"=••"O""OCo•en">' ,-~ Aell ~+·e~I s~~1·e WA ~AL2' :::00·4~1 .. r:~s h 2oc·4~1 -s.,n ('Q,) )> l'v 0 ·r ,', tJj ~~-nT ..;Jl: •O ~? "' C r Q, [:JC>i3 z G) ~ Zo r [ m ' < ' m r -~ ~ ~ -.. PLANS: UNITS l(L) AND J(K) M ~: ~o 0 I ~ -- 0 ' " if;[' ' w ", D C ' F i tod] I Ef•·· =---:;:, 9 r m < , [' C Sa m ' ,· , I " ~I z ' -0 '~_J . 330 BREMERTON ,,,.,-_"''"~ 13611' A'.'lNJ" " s r m < ' m ' ,· "' -·· DRISCOLL ARCHITECTS ~ <,..,~'""',-..,co.,•""'"" llt B,·I s1, • .,;.,~."1,1c w~ BBi~, 2U6·441•7/U5~i06·4'-i'~.5n (Fu,j )> 0J 0 0 m I '1 ]J 01 > ]J OJ I '1 '" - C er CJ I '1 U) -, ]J 01 01 ---, ELEVATIONS BLDG A & B-F -I -. ••• q ••• -- ' I l•j ... •• •• •• ,n , .• , .. , .. .. , [II_Q ... D n :• • D D a D' _u ,u, D :• II ... 330 BREMERTON 1.'if+h ii./C~IJ~ r1~,-·~n ·I/A 1,1,1111·1,1 1, ,,,,,1 .. ,,,,1-, ·- ,,,.- '" 1111, ·-·1,,,, -.-,,, ' i ·111 : ~ , ,r,·1rji,11ii, ,1,1-11 •• n i"1ii111 ..,,,l,0 JI ••'ii 1>,' •• 1 1 1 JI.I 1·1 11-- IJl 1111i•I I I 11111'1'1 • 1111111 11: 0 ii Iii! I ':1~f ll!il'l'I I iji', 01 C'--'~-'""'7~~~----JJL _ ' _ -j A '"'''I'' II -J> I. en I AJ f;='""'-_J ,. iT] 01 --I 1:11 11 1,, ..•• ,,,,[ •• ... ... ... •••• \)i ·• ii , .•. ,,, l~ ,,,,,, q .... 11 li ' 1 DRISCOLL ARCHITECTS 115 Re'I ;1,ee! 5eottlc· WO 2~0·••1 11cs~2Js <1-11 .'i.07.'I )> G-J 0 m C I - CJ z G) (__ '- 12? 7' co ·~ I~ m C - ' :.__J z C) ·- Ro 7' (j) ---, :,:: CT] '1 ---, .... ---ir II II_-:._ II ]I T-t~ II ·ti • I ' I •• LL Ji ii 'Ill ··11 •• 0 ---· .. - 0 -"'"~ I ,!ill! .. iiii . ••• II .11 • • I= I• ::11 ~ •• L__: ···11 •••• -ill ii IE II •• I •• .... .... .... ELEVATIONS BLDGS G-H l&L, J&K 330 ~ ll1jll r --,, • 11!, I ilili 1--· Ii .. 11,, ,'.) k' Ii '.!-'.!' I c-:c r 1111, :i~~ 1, Iii ,r-GO I .!! u C'l ~- I I "'' I' -......... I,, X I I ,- I -I ' rr .. u Iii 11:: z Cl I ~- ~ :: k' • 1, ,.I· ·-! I -1 '•Ill• IU'lf) -I -- ---i :,J I C'l n ---, .... '> ,, .... BREMERTON CCSMENTS ·,5c,th A'/C~Ul l.'~r lor·, WA I • 1 I ~ I I (/) 0 n CJ C r 0 -z C) 0 I :T (/) ---, :.,(: ~I ,, I -I ----/I 11C Rel Sfrec• S•aHle WA 91',121 :'(6 · 44 1 '770~ A £~'o '~~ L '~3U (' o,:, : ' • . ' • • Ii ,, t i f i £J l ii ,, ' ,, I ~---f 11 ' ' ,, ' ,, r-1~~11 :11!:ii{i;, SEATILE REDEVELOPMENT, L.L.C. "I 1,: I :'I 1: BREMERTON TOWNHOMES I j~, I~ :'j i; I§ ~,rr 0< ..:m<lN.Pffl::Lll\,/1/'JARY \..ANOSCAPE PLAN DETAILS o< NOTES ~-s~1..-crON NG COUNTY CPARTMENT ot ASSESSMENTS , Ii..: .;. " ', I -- • --'! + s,.,, 1.1200 11". 10Q'I 11\r=~d,3- i I 1 ', 4""'""' • i-~~=---1, ;{'\:;"'•~;:;::;~;.:: -· 4 ,l'j-:.;r_ ~ .;-.,,.;;,',.,.---''-...::-~ if' :~ ,.: ,~,'.. •• -i j ~·; l rJ A PORTION OF THE N.E. 1/4 OF THE N.W. 1/4. SECTION 15, TOWNSHIP 23 N .. RANGE 5 E., W.M n NOTE: I STREET TREE LOCATIONS AND QUANTITIES ARE APPROXIMATE AND SHALL BE ADJUSTED PER FINAL DRIVEWAY AND UTILl!Y:l,QCATIONS hl'.If~,'-~t'=..~ NE 3rd CT. [:l ~ I rs!C>l!DL.....,...,,,a. """"""'--"'''"' '"""....-c•='""""' .....,...,,..D O' ... El '""E r,"f'"CAI_ .,...,., -·· _,__D "' .... """""""' ,...r,e a, '""""LOO,...,FEl<"' ....,.,_.,.c,o,.,_-,,- _ ___,_ ----- ~ l-··-·· ;!'-:_'.ac ... D·"""° fOlt!"'\.N<~:~-:,'°L·> 17 SCALE: 1" -20' p ~ .. - I i• ~! n )I O>'.,Dt~-'-""'POC-_,._,-.,_,c;AL_,o,o O<,El"'L-)'<:,0,""-""'L- {r l 1 :1;:;;o•:: ~ i ~ -t '~ ...., --· ~ • m i • m ri i ti • Ii; J! ,. I JI ' t; ~ 1 U 3 ]l 'l ' . m i. ! ;: • k! ii ! ' (f) ; w u ~ j 0 ,.: I 3 z z. ~ :1: ~ ~ 0 ~ ~ I-3 > z ~ I!; 0 ~ w I--~ a: ; ~ w. ~ ~ LD LU f/) a: ' Cl ! ' ' :: :.. '"'--_:: ""'""", ... "" ·--,-.,o .. •""'(!'!!' "'" L-1 1 or 2 ""'"' r, \"..,..-''"'"""'''''•-,,.<"""""' ,.,, ,~ "·-,,,,,,.,, ,,. .. -~ "'~ = I J_ ______________ _) 6R:J1[RT:JN I, _! __________ _ ' ' I ' ' I -:PRIVt-F: ISIT--FTT __ _ i I I ! I ! \____ _______ Jl'---j ________ _ ,., !i --~--rl i --""'""-"""',........ --------- N c_, QC '"" If iii " ij! ,'-..) 111 " ' ~ .. -I 'i i" .. , N 'i• ' . \~/i ~~~ 's· "d §~ N co •.-:) ------:: :_[} N J; 'I~ ·'.. ',r' ' -, "' I' !' ~ I ,l ! J. . ··: ~ I a s ' -''I' 111 " IEII 'iPN'ILJLI!N(ll §NGINffM IQ l•at 'l ! ' '' SEATTLE REDEVELOPMENT, LLC. :~.;:-::,::,.s:.:..,.-I e 14, I'¥ I !l "= ' • ' BREMERTON TOWN HOMES www.aamcrlil.com --'11-"' i i I .i di CITYOF~ PRELIMINARY LANDSCAPE PLAN -~-"""QN "'"'" w., •• I ~~="7-~, I .....,,,, ___ """''" ' ' ' AFFIDAVIT OF SERVICE BY MAILING ST A TE OF WASHINGTON ) ) ss. County of King ) Nancy Thompson being first duly sworn, upon oath, deposes and states: That on the g<h day of January 2007, affiant deposited via the United States Mail a sealed envelope(s) containing a decision or recommendation with postage prepaid, addressed to the parties of record in the below entitled application or petition. Signature: SUBSCRIBED AND SWORN to before me this ?:/4 day of ,_kl. .. i,wc ,y , 2007. • · :""·\\\i<,1 ~. i, y·..,; A ',i" ary Public iJ:) and for the State of Washington esiding at k:(. .. q . .f-r-y-\ , therein. ', ,·. ,· .· . r;, . i) .. :;:, Application, Petition or Case No.: Bremerton townhomes Preliminary Plat LUA 06-133,PP, CU-A, SA-A, ECF The Decision or Recommendation contains a complete list of the Parties of Record. December 20, 2007 Eric S. Pennala, AICP Davis & Kurth 1201 Monster Road SW, #320 Renton, WA 98057 VIA: Facsimile: (425) 226-9227 CIT )F RENTON Planning/Building/Public Works Department Gregg Zimmerman P.E., Administrator SUBJECT: PROPOSED REVISIONS TO APPROVED SITE PLAN FOR BREMERTON AVE TOWNHOMES (FILE LUA-06-133, SA-A, PP, CU-A) Dear Mr. Pennala, I am in receipt of your letters of November 7th and 191 ", in which you request a revision to the approved site plan for the Bremerton A venue Apartments. The request is summarized below. Request 1. Revise the unit count from 26 to 30 units; thus revising the lot count from 26 to 31 parcels (30 residential lots plus one recreation/storm vault tract). 2. Increase the density from 19.54 dwelling units/acre to 20 dwelling units/acre. 3. Create park/storm drainage vault tract (approximately 2,000 square feet). 4. Reduce the right-of-way width from 42 feet to 24 feet. 5. Remove 42 existing protected trees. Renton Municipal Code, Section 4-9-2001, allows minor adjustments to an approved site plan, provided: 1. The adjustment does not involve more than a ten percent (I 0%)increase in area or scale of the development in the approved site plan; or 2. The adjustment does not have a significantly greater impact on the environmental and · facilities than the approved plan; or 3. The adjustment does not change the houndaries of the originally approved plan. In addition to the requested site plan modification, the proposal requires an amendment to the approved preliminary plat. The proposed revisions would require an amendment to the approved preliminary plat. Renton Municipal Code, Section 4-7-09QM pertains to plat amendments and states that at any time after preliminary plat approval and before final plat approval, the applicant may submit an application to the Administrator that proposes an amendment to the approved or conditionally approved preliminary plat. Minor amendments may be granted by the Administrator. However, major amendments require a new application, and a new public hearing. -------I-0-55_S_o_u_th_G_ra_d_y_W_a_y ___ R_e_nl-o-n,-W-a-s-hi-ngt-on_9_80_5_7 ______ ~ @ This paper contains 50% recycled material, 30% post cons Urn er AHEAD OF THE CURVE A Major Amendment includes, but is not limited to: a) Any amendment that would result in or would have the effect of decreasing the aggregate area of open space in the subdivision by ten percent (10%) or more; b) Any amendment that would result in increasing the number. of lots in the subdivision beyond the number previously approved; c} Any amendment that would result in or have the effect of reducing the residential dwelling unit density for the site below the allowed minimum density; d) Any amendment that would result in the relocation of any roadway access point to an access pointto an exterior street from the plat; e) Any amendment that proposes phasing of plat development; or, f) Any amendment that, in the opinion of the Administrator, would significantly · increase any adverse impacts or undesirable effects of the plat. Because the proposal would increase the number of lots in the subdivision beyond that which was previously approved, a Major Amendmentis needed. In addition, a modification from street standards would be neededin order to reduce 'the road width froin the previously modified width of 42-feet (from 50 footrequirement) to 24 feet. A Major Amendment is the equivalent of a new project, and ni'q~iresa new application and a public hearing with the City's Land IJse Hearing Examiner. Therefore, the request for modification of the site plan cannot be eonsld~i:edatthis.time ,md wouJ!l need to be included with _the. application to the Hearing Exan'l!'ner,for a;IV!ajorJ'lat ;\mendment. Please contact Laureen Njcolay, Senior Pla.10\er·at.425'-430-729.4 for assjstance with submittal requirements for the Major Amendment ap1!1\~~tiorlprpcess. · Sincerely, fJiJ wa1;t, Neil Watts, Director Development Services Division cc: Jennifer Henning, Planning Manager Laureen Nicolay, Senior Planner Parties of Record: l]IDavis&Kurth November 19, 2007 Neil Watts, Director Development Services City of Renton 1055 S. Grady Way Dear Neil: aOPMENT PLANNING DEV CITY Oi= RENTON DEC 1 3 2007 RECEIVED Wit'1 this letter Davis & Kurth (Applic.,nt) requests a minor adjustment to the approved Bremerton Avenue town home site development plan that was approved by the Renton City Council on March 26, 2007. The Applicant requests modification of the approved site plan to incorporate 30 units and add a park/vault tract that totals approximately 2,000 square feet. without increasing the 1.80 acre site. Project density of the approved Bremerton Avenue Town Home site development plan equaled 19.54 units per acre, with the density of the proposed modification totaling 20 dwelling units per acre, or a two percent (2%) adjustment. Pursuant to RMC 4-9-200(1), the Administrator may approve a minor modification to an approved site development plan may be permitted if the amendment complies with the criteria below. The Applicant's responses to the criteria are in bold Italic. 1. Involve more than a ten percent (10%) increase in area or scale of the development in the approved site development plan; or Response: The project site area will not be increased. Project density for the approved site development plan equaled 19.54 units per acre. Density for the proposed modification would be 20 dwelling units per acre, or a two percent (2°/o) adjustment in the scale of the approved development. 2. Have a significantly greater impact on the environment and facilities than the approved plan; or Response: The proposed modification will !1.21 have a "significantly" greater Impact on the environment and facilities than the approved plan. The proposed modification will add 3 to 4 additional vehicle trips to Renton's transportation system. To mitigate those system wide transportation Impacts, the applicant will pay a traffic mitigation fee equal to $75 for each net new dally vehicle trip prior to recording of the plat. The 42 existing significant trees on the site will unfortunately be removed for the construction of roadways, a storm water vault, the instillation of utllity lines, and the preparation of building pads. A total of 11-2-lnch caliper trees w/11 be required to be planted to comply with the City's retention/replacement requirements. New lots (credit given for existing residences) x $530.76 = $14861.28) and is payable prior to the recording of the final plat. 1201 Monster Rd. SW #320 • Renton. WA 98057 mDavis&Kurth The proposed modification will Incorporate 4 additional units into the approved site development plan. To mitigate potential impacts to the City's Police and Fire Emergency Services, the Applicant will pay a Fire Mitigation Fee, based on $388.00 per new lot prior to the recording of the final plat. The fee is estimated at $10,864 ($388.00 x 28 = $10,864). This type of development is compatible with the surrounding uses, the residential town homes would serve as a transition from the higher intensity uses of the commercial areas to the lower intensity single- family residential uses to the south. With the incorporation of the above mitigation measures, the proposed minor modification will promote the health, safety, and welfare of the City of Renton and not result in significantly greater impacts on the environment and facilities than the approved plan. 3. Change the boundaries of the originally approved plan. Response: The propOSed minor modification does not change the boundaries of the originally approved plan. Thank you for the opportunity to process this Minor Modification with the City of Renton. If you need any further information feel free to contact me. Enc. 1201 Monster Rd. SW #320 • Renton, WA 98057 .-..c,:,_ •• • ,.-.,-, .-,.-,.-, ,.,..,.,. . ,-•.. ·-'.,..,., .-,.-,, ,..,,.,,.. ... Jennifer Henning -RE: Bremerton TH · ·· or Modification Request From: To: Date: Subject: "Eric Pennala" <ericp@davis-kurth.com> "Jennifer Henning" <Jhenning@ci.renton.wa.us> 11/26/2007 7:4328 AM RE: Bremerton TH Minor Modification Request Good Morning Jennifer, I trust your Thanksgiving was enjoyable and you ate far too much turkey, like me. I just wanted to see if you had received and reviewed the revised minor modification request I sent over last week. If not, could you provide me with an ETA for your review and process determination? Thanks, Eric S. Pennala. AICP Planning Manager 1201 Monster Rd. SW #320 Renton, WA 98057 (o) 425-228-5959 (c) 206-718-6903 (f) 425-226-9227 -----Original Message----- From: Jennifer Henning [mailto:Jhenning@ci.renton.wa.us] Sent: Friday, November 16, 2007 3:08 PM To: Eric Pennala Cc: Elizabeth Higgins; Jill Ding Subject: RE: Bremerton TH Minor Modification Request Hi Eric, Thanks for the clarification. Please revise your letter requesting the minor modification to the approved site plan to include the information noted. You'll want to list the specific changes, and provide a justification for the requested change ... for example ... "applicant requests to increase the size of the office building by 1,262 square feet, from 289,457 gsf to 290,719 gsf in order to accommodate a Customer Service Center, and to reconfigure the surface parking lot to increase the number of parking stalls from 893 to 922 to serve customers and vendors. The requested revisions would result in a decrease in the size of the landscaped courtyard adjacent to the west entrance, and a reconfiguration of the landscaping as detailed below ........ " The requested reduction in the setback cannot be granted if it was a condition of approval; you would have had to appeal the condition within 14 days of the date of the decision. If this is a Code requirement, then you would need to apply for a setback variance. There is no guarantee that this would be granted. For the reduction in Parks Mitigation Fees, a separate letter must be sent to the City's Environmental Review Committee. You would have to make a convincing argument that the recreation provided by the development would offset any use of City Parks and Recreation facilities. I have only seen part of the fee waived for the provision of a community center with swimming pool, or bike lanes, or regional Page 1 • Jennifer Henning -RE: Bremerton TH • •· or Modification Request trail systems. »> "Eric Pennala" <ericp@davis-kurth.com> 11 /16/07 11 :24 AM >» Hi Jennifer, The minor modificc1tion request is to incorporate 30 units and a park/open space area with a fountain into the development. (See Attached).The request will not increase the net density of the proposal over the maximum 20 du/ac allowed. I also attached a color pdf of the site plan. (See Attached)We also request a correlative reduction in the park impact fee based on the recreation area provided. Additionally, we request elimination of the required 15' structure setback adjacent to PIN# 152305-9030. It is my understanding that this was required based on neighborhood opposition to Town home aesthetic concerns. Town home elevation would be the same as the ones we are building down the street in the Galloway development.(pgs. 11 and 12 of the attached Town home structural plans) Thanks, Eric S. Pennala, AICP Planning Manager -----Original Message----- From: Jennifer Henning [mailto:Jhenning@ci.renton.wa.us] Sent: Friday, November 16, 2007 10:50 AM To: Eric Pennala Cc: Elizabeth Higgins Subject: Re: Bremerton TH Minor Modification Request Hello Eric, It is unclear to me what the change in the proposal is from what was approved by the Hearing Examiner. Could you please provide me with an explanation of what the request is? Are you increasing the number of units? Please provide the reason that the density is increasing. Thank you. >» "Eric Pennala" <ericp@davis-kurth.com> 11 /16/07 10:21 AM »> Good Morning Jennifer, Elizabeth informed me earlier this week that she routed our minor modification request for the Bremerton Town Home project to you on Tuesday. I was wondering if you had a chance to take a look at the request and develop some initial thoughts. I would appreciate your input and guidance related to processing the minor modification in the most efficient and expediouis manner possible. If you have any questions or comments related to my request feel free to contact me at you earliest convenience. Page 2 Jennifer Henning -RE: Bremerton TH • ·; or Modification Request Thanks, Eric S. Pennala, AICP Planning Manager Davis & Kurth CC: "Elizabeth Higgins" <Ehiggins@ci.renton.wa.us>, "Jill Ding" <JDing@ci.renton.wa.us> Page 3 Jennifer Henning -Fountain Renderin ·raft 2 -11-06.pdf ' ....__ ·~,.,. ,/\,•; , . ./.-,; '" ,-1 ~ ~ .:»,~'.~ "' . 0 v··-.:: ,, Page 1 Ooavis&Kurt _ November 7, 2007 Neil Watts, Director Development Services City of Renton 1055 S. Grady Way Dear Neil: R Ec1rroFA£Nrotv CEIVED Novo B 2001 BUILDINGO,VJSION With this letter Davis & Kurth requests a minor adjustment to the approved Bremerton Avenue town home site development plan that was approved by the Renton City Council on March 26, 2007. Pursuant to RMC 4-9-200.1, the Administrator may approve a minor modification to an approved site development plan may be permitted if the amendment will not: 1. Involve more than a ten percent (10%) increase in area or scale of the development in the approved site development plan; or Response: The project site area will not be increased. Project density for the approved site development plan equaled 19.54 units per acre. Density for the proposed modification would be 20 dwelling units per acre, or a two percent (2%) increase in the scale of the approved development. 2. Have a significantly greater impact on the environment and facilities than the approved plan; or Response: This type of development is compatible with the surrounding uses, the residential town homes would serve as a transition from the higher intensity uses of the commercial areas to the lower intensity single-family residential uses to the south. The proposed minor modification will promote the health, safety, and welfare of the City of Renton. The proposed minor modification will not result in significantly greater impacts on the environment and facilities than the approved plan. 3. Change the boundaries of the originally approved plan. Response: The proposed minor modification does not change the boundaries of the originally approved plan. Thank you for the opportunity to process this Minor Modification with the City of Renton. If you need any further information feel free to contact me. Sinc~ __ ly, • .l',....~ .. ...._ : • { . ..),I _/ --,~--< • Enc-8. Perrnala, AICP Planning Manager Enc. 1201 Monster Rd. SW 11320 •Renton.WA 98057 Office: (425) 228-5959 • Fax: (425) 226-9227 www.davis-kurth.com w z w > -< z 2 cc w " Cu O' rn -o-- "'--- Lorer1te' Vue _ 10 Jo () f\'Y o CIT"\_ )F RENTON ~.~. ,<~ City Clerk /. ~ ? Kathy Keolker, Mayor Bonnie I, Walton i-'~)1'\/'1'0"·~-------------------------------- March 28, 2007 Marc Rousso Seattle Redevelopment LLC PO Box 2566 Renton, WA 98056 Re: Bremerton Townhomes Preliminary Plat, LUA-06-133, ECF, PP, CU-A 320 & 130 Bremerton Avenue >IE Dear Applicant: At the regular Council meeting of March 26, 2007, the Renton City Council adopted the recommendation of the hearing examiner to approve the referenced preliminary plat, subject to conditions to be met at later stages of the platting process. Pursuant to RCW, a final plat meeting all requirements of State law and Renton Municipal Code shall be submitted to the City for approval within five years of the date of preliminary plat approval. IfI can provide additional information or assistance, please feel free to call. Sincerely, .·7 · / i .'_/,/-_A • i06-)1..,;,t-<..L ~ Ll.i (fti...,T' - Bonnie I. Walton City Clerk cc: Mayor Kathy Keolker Council President Toni Nelson Jennifer Henning, Principal Planner Parties of Record (7) 1055 South Grady Way-Renton, Washington 980--5-7---(4-2.-\)-4-30---65_1_0_/_FAX--(4_2_5_) 4-3-0--6-5-16-~ Al[EAD OF THE CLRVI:. li't 1 h,s n"'n"'r ,:nnt,rnoe; fiO',i rr,rvnfcfl m;cilP.ri;il ?.D% nnsl consumer March 26. 2007 ADMINISTRATIVE REPORT CONSENT AGENDA Council Meeting Minutes of 3/19/2007 Appointment: Planning Commission Vacation: Index Pl NE, A&D Quality Construction Company, VAC-07-001 Development Services: Traverso Short Plat, ROW Dedication, Redmond Ave NE, SHP-06-021 Plat: Bremerton Townhomes, Bremerton Ave NE, PP-06-133 . --··· ---·---- UNFINISHED BUSINESS Committee of the Whole City Clerk: Cable Franchise, Basic Programming Service Rate Renton City Council Minutes l 08 Comcast improperly included the business and occupation tax in the basic service rate, and excluded the FCC regulatory fee in its calculation of maximum permitted rates. Ms. Wine explained that the settlement proposes the following in regard to FCC Forms 1235 and 1240: eliminating the FCC Fonn 1235 fee, eliminating the business and occupal1011 tax, including the FCC fee in the calculation of the FCC Form 1240 ma, imum permitted rates, and providing the requested advertising revenue information. She noted that with this settlement, Comcast will not be able to charge subscribers the additional $1.16 per month. Public comment was imited. There being none, it was MOVED BY NELSON, SECONDED T3Y PALMER, COUNCIL CLOSE THE PUBLIC HEARINGS. CARRIED. (Sec later this page and I 09 for Committee of the Whole reports.) Chief Administrative Octicer Covington reviewed a written administrative report summarizing the City's recent progress towards goals and work programs adopted as part or its business plan for 2007 and beyond. Hems noted included: * Washington State Department of Transportation will begin construction of the City/WSDOT Springbrook Creek Wetland and Habitat Mitigation Bank project on April 2. The construction will occur on City-owned property located south of SW 27th St. between Oakesdale Ave. SW and Lind Ave. SW and north of SW 41 st St. Work on the project will extend over a two- year period. Items on the consent agenda are adopted by one motion which follows the listing. Approval of Council meeting minutes of 3/19/2007. Council concur. Mayor Keolker appointed Michael Chen, 6214 NE 5th Ct., Renton, 98059, to the Planning Commission for a three-year term expiring 1/31/2010. Refer to Community Services Committee. City Clerk submitted petition for vacation of portion of Index Pl. NE, between NE 7th and NE 8th Streets; petitioner A&D Quality Construction Company, LLC, 220 SW Sunset T31vd., Suite E202, Renton, 98057. Refer to Planning/Building/Public Works Administrator; set public hearing on 4/23/2007 to consider the petition. (See page 110 for resolution setting public hearing.) Development Sen ices Division recommended acceptance of a deed of dedication for additional right-ol~way in the vicinity of Redmond Ave. NE and NE 19th St. to fulfill a requirement of the Traverso Short Plat. Council concur. ! 1 · Hearing Examiner recommend. ed approval, with conditions, of the Bremerton Townhomes Prelirninarv Plat: 26 attached townhome units on 1.8 acres located , at 320 and 330 Bremerton Ave. NE. Council concur. ! MOVED BY NELSON, SECONDED BY LAW, COUNCIL APPROVE THE CONSENT AGENDA AS PRESENTED. CARRIED. Council President Nelson presented a Committee of the Whole report regarding the cable franchise renewal basic programming rate regulation and network upgrade add-on calculatJon and the FCC (Federal Communications Commission) Forms 1235 and 1240 rate review and settlement. The Committee recommended approval of the revised FCC rate orders and the settlement offer from Comcast Cable Communications, LLC. The Committee further recommended that the resolution regarding the matter be presented for reading L •. 'OF RENTON COUNCIL AGEND; LL 1 AI# 1. e. Submitting Data: For Agenda of: 3/26/07 Dept/Div/Board .. Hearing Examiner Staff Contact.. .... Fred J. Kaufman, ext. 6515 Agenda Status Consent.. ............ X Subject: Public Hearing .. Correspondence .. Bremerton Townhomes Preliminary Plat Ordinance ............. File No. LUA-06-133, PP, CU-A Resolution ............ Old Business ........ Exhibits: New Business ....... Hearing Examiner's Report and Recommendation Study Sessions ...... Legal Description and Vicinity Map Information ......... Recommended Action: Approvals: Legal Dept.. ...... . Council Concur Finance Dept ..... . Other. ............. . Fiscal Impact: Expenditure Required .. . NIA Transfer/ Amendment.. .... . Amount Budgeted ...... . Revenue Generated ........ . Total Project Budget City Share Total Project.. SUMMARY OF ACTION: The hearing was held on December 19, 2006. The Hearing Examiner's Report and Recommendation on the Bremerton Townhomes Preliminary Plat was published on January 8, 2007. The Examiner requested more information from Staff. That information was provided on February 13, 2007. On February 26, 2007 the Examiner sent a letter to the applicant and parties of record stating that the information received appeared to be in order and that the parties would have 14 days to appeal the decision. The appeal period ended on March 12, 2007. No appeals were filed. The Examiner recommends approval of the proposed preliminary plat subject to the conditions outlined on pages 13 and 14 of the Examiner's Report and Recommendation. Conditions placed on this project are to be met at later stages of the platting process. STAFF RECOMMENDATION: Approve the Bremerton Townhomes Preliminary Plat with conditions as outlined in the Examiner's Report and Recommendation. Rentonnct/agnblll/ bh CIT >F RENTON Hearing Examiner Fred J. Kaufman '\-<'\:Y 0 0~,, >0-~> ·~ + ~ -2': Kathy Keolker, Mayor ~N~o,,;,-------------------------- February 26, 2007 Mark Rousso Seattle Redevelopment, LLC Box 2566 Renton, WA 98056 RE: Bremerton Townhomes Preliminary Plat LUA-06-133, PP, CU-A, SA-A, ECF Dear Mr. Rousso: This office has reviewed the new submittal as well as staffs comments. It appears that the new plan meets Code and the concerns raised by this office. The matter will now be referred to the City Council. If the parties are not satisfied with this decision, it may be appealed to the City Council within 14 days of this decision. If this office can provide any additional assistance, please feel free to write. Sincerely, Fred Kaufman Hearing Examiner City of Renton FK/nt cc: Larry Warren, City Attorney Neil Watts, Development Services Jennifer Henning, Development Services Jill Ding, Development Services Parties of Record ----l-0-55_S_o_u_th_G_r_a-dy-W-ay ___ R_e_n-to_n_, W-as-h-in-gt_o_n_9_8_05_5_--(-42_5_)_43-0--6-5-l5 ____ ~ @ This paP€r contains 50% recyded material, 30% post consumer AHJ,,\ll OF THE CURVE DATE: TO: FROM: SUBJECT: PLANNING/BUILDING/ PUBLIC WORKS DEPARTMENT MEMORANDUM February 13, 2007 Hearing Examiner Jill K Ding, Senior Planner j1}- Bremerton Townhomes, LUA06-133, PP, CU-A, SA-A, ECF Please find attached a copy of a revised preliminary plat map and site plan. The revised materials address the staffs concerns regarding the proposed locations of the buildings with regards to the applicable setback requirements of the CA zone as well as the parking and pedestrian connections. In particular, the submittal addresses conditions 7-9, 11, and 12 of the decision. Staff recommends that the Hearing Examiner approve the Bremerton Townhomes project with conditions 1-6, 10, 13, and 17 in the previous decision issued by the Examiner on January 8, 2007. q: \data_ center\templates\pbpw\standardrnemo.doc CA NE 3rd -Ct. R-lOCP) "' R-10 I -0 R~8 RMH R-8 .· :-·-----------·- ; RCCP) CP) CA w z Q) :,,. ~ CA C, R-10 G6 · 22 T23N RSE W 1/2 ~ ZONING ----...... °"'......, ~ = TIICIINICAL IU.VJCIIS R-8 CA R-1 CA R-10 R-8 NE 21R:!BS µ.:J ,/ R-8Z Q) :,,. <,: -cl Q) ·- SE 142nd St. 0 1::, tr F6 15 T23N R5E W 1/2 5315 2. ENVIRONMENTAL REVIEW Pursuant to the City of Renton's Environmental Ordinance and SEPA (RCW 43.21C, 1971 as amended), on November 20, 2006, the Environmental Review Committee issued a Determination of Non-Significance - Mitigated (DNS-M) for the Bremerton Townhomes project. The DNS-M included 6 mitigation measures. A 14-day appeal period commenced on November 27, 2006 and ended on December 11, 2006. No appeals of the threshold determination were filed. 3. COMPLIANCE WITH ERG MITIGATION MEASURES Based on an analysis of probable impacts from the proposal, the Environmental Review Committee (ERC) issued the following mitigation measures with the Determination of Non-Significance -Mitigated: 1. The applicant shall comply with the recommendations found in the geotechnical report prepared by Earth Solutions NE, LLC, dated July 19, 2006. 2. The applicant shall be required to provide a Temporary Erosion and Sedimentation Control Plan (TESCP) designed pursuant to the Department of Ecology's Erosion and Sediment Control Requirements outlined in Volume II of the Stormwater Management Manual and provide staff with a Construction Mitigation Plan prior to issuance of Construction Permits. This condition shall be subject to the review and approval of the Development Services Division. 3. The detention system for this project shall be required to comply with the requirements found in the 2005 King County Surface Water Design Manual to meet both detention (Conservation Flow control -a.k.a. Level 2) and water quality improvements. 4. The applicant shall pay a Parks Mitigation Fee based on $530. 76 per each new single family lot. 5. The applicant shall pay a Traffic Mitigation Fee in the amount of $75 for each new net daily trip prior to the recording of the final plat. It is anticipated that the proposed project would result in the payment of $9,991.50 (152 net new daily trips x $75 = $9,991.50). 6. Staff recommends that the applicant pay a Fire Mitigation Fee based on $388.00 per new single family lot prior to the recording of the final plat. The fee is estimated at $9,312 ($388 x 24 = $9,312). PARTIES OF RECORD BREMERTON AVENUE TOWNHOMES LUA06-133, CU-A, ECF, SA-A, PP Eric LaBrie ESM Consulting Engineers 33915 1st Way S ste: #200 Federal Way, WA 98003 tel: (253) 838-6113 eml: eric.labrie@esmcivil.com ( contact) Charles Ratzsch 320 Bremerton Avenue NE Renton, WA 98059 ( owner) Updated: 10/27 /06 Marc Rousso Seattle Redevelopment LLC PO Box 2566 Renton, WA 98056 tel: (206) 948-8899 (applicant) Alice Knight Trustee for Violet Bliss Estate 330 Bremerton Avenue NE Renton, WA 98059 (owner) (Page 1 of 1) • HEARING EXAMINER'S REPORT January 8, 2007 OFFICE OF THE HEARING EXAMINER CITY OF RENTON Minutes APPLICANT: LOCATION: SUMMARY OF REQUEST: SUMMARY OF ACTION: DEVELOPMENT SERVICES REPORT: PUBLIC HEARING: Mark Rousso Seattle Redevelopment, LLC Box 2566 Renton, WA 98056 Bremerton Townhomes Preliminary Plat File No.: LUA 06-133, PP, CU-A, SA-A, ECF 320 & 330 Bremerton Avenue NE Preliminary Plat approval, site Plan approval, and Conditional Use Permit approval to subdivide a I .8-acre site into 26 lots for the future development of attached townhome units. Development Services Recommendation: Approve subject to conditions The Development Services Report was received by the Exammer on December 12, 2006. After reviewing the Development Services Report, examining available information on file with the application, field checking the property and surrounding area; the Examiner conducted a public hearing on the subject as follows: MINUTES The following minutes are a summary of the December 19, 2006 hearing. The legal record is recorded on CD. The hearing opened on Tuesday, December 19, 2006, at approximately 9:00 a.m. in the Council Chambers on the seventh floor of the Renton City Hall. Parties wishing to testify were affirmed by the Examiner. The following exhibits were entered into the record: Exhibit No. 1: Yellow file containing the original Exhibit No. 2: Neighborhood Detail Map application, proof of posting, proof of publication and other documentation pertinent to this request. Exhibit No. 3: Preliminary Plat Mao Exhibit No. 4: Conceptual Drainage and Utilitv Plan Exhibit No. 5: Grading and Tree Plan Exhibit No. 6: Conceptual Landscape Plan Exhibit No. 7: Elevations Bldg A & B-F Exhibit No. 8: Elevations Bldg G-H, l&L, and J&K Bremerton Townhomes Preli ary Plat File No.: LUA-06-133, PP, CU-A, SA-A, ECF January 8, 2007 Page 2 Exhibit No. 9: Zoning Mao Exhibit No. 11: Revised Landscape Plan Exhibit No. 10: ERC Miti,;,ation Measures Exhibit No. 12: By Reference, Laurelhurst Division 3 Preliminarv Plat The hearing opened with a presentation of the staff report by Jill Ding, Senior Planner, Development Services, City of Renton, 1055 S Grady Way, Renton, Washington 98055. The property is located north of the Laurelhurst Division 3 development, east side of Bremerton Avenue NE and south of NE 4"' Street. The site is located within the Commercial Arterial Zoning designation and within the Commercial Corridor Comprehensive Plan designation. The site is approximately 1.8 acres. The proposal is to divide the property into 26 lots for the construction of 26 attached townhome units. There would be two 3-unit structures located on the southeast portion of the property and ten 2-unit structures. There are no critical areas or wetlands on the project site. The Environmental Review Committee issued a Determination of Non-significance -Mitigated with 6 mitigation measures. No appeals were filed. The proposed plat is consistent with the Commercial Corridor Land Use and Community Design elements. The proposal for 26 lots resulted in a net density of 19.85 swelling units per acre, which complies with the density requirements for the CA zoning designation. To have standalone residential in a commercial zone, the applicant has to justify that there is no other commercially viable use of the property that is available. The property does not have any frontage along NE 4"' and that would hinder any commercial use of the property. The only commercial use that would be viable would be an auto repair shop. Staff does concur that without frontage on NE 4"', the site is severely restricted for commercial use. Further, the site is essentially surrounded on 3 sides by residential uses. The net density would be 19.85 dwelling units per acre, which does comply with density requirements for the CA zoning designation. The proposal is located in both the CA zone and the NE 4th Street Corridor Business District overlay. The CA zone does not mandate a minimum lot size, width or depth, the NE 4"' Street Corridor Business District does mandate a minimum lot size of 1,200 square feet. The proposed lots appear to have sufficient building area for the development of townhomes. Access to the site is proposed via a new internal access, NE 3'd Court, off of Bremerton Avenue NE. Full street improvements including curb, gutter, sidewalk, and street lighting are required. A 15-foot radius would be required at all intersections. Fire, Traffic and Parks Mitigations Fees would be imposed on this project. There currently is a 26-foot wide proposed private street which provides primary access to Lots 15 and 16, that private street should extend to the southern property line. There will be a water line within that easement and will extend all the way to the south property line. The topography is relatively flat. The applicant would be required to mitigate for any erosion or off-site sedimentation by complying with the Department of Ecology Manual for Erosion Control. There are a total of Bremerton Townhomes Prelim •.. ry Plat File No.: LUA-06-133, PP, CU-A, SA-A, ECF January 8, 2007 Page 3 44 significant trees on the site, requiring the applicant to retain or replace a total of 11 trees. They plan to retain 5 trees and so will be replacing 6 trees. The site is located within the Renton School District and they have indicated that they would be able to handle the proposed 11 additional students. A drainage report was submitted, the existing drainage from the north half of the site sheet flows into the existing depression area. The drainage from the south half sheet flows to the southwest comer of the project site. A detention and wet vault will provide drainage control, these will be located in the southeast portion of the project site under the private paved street. An existing 8-inch water main is located in Bremerton Avenue NE, in addition an 8-inch water main would be required to be connected to the main in Breme1ion and looped through the site. The main would be extended to the south in a 15-foot easement to the City of Renton. All of the units would be required to be sprinklered Bremerton Avenue NE also has an 8-inch sewer main as well as an existing 8-inch sewer main on the north and east side of the site. A sewer main would be required to be installed with this project. Conditional Use Criteria: Staff feels that this type of development is compatible with the surrounding uses, the residential townhomes would serve as a transition from the higher intensity uses of the commercial area to the lower intensity single- family residential uses to the south. The development would further provide pedestrian connections to the surrounding uses along the north, south, east, and west sides of the property. Site Plan Criteria: The proposed building lot coverages range from 17% to 43%, which is well below the maximum 75% permitted in the zone. The setbacks can be reduced down to zero feet providing there are no blank walls located within the reduced setback. Front yard maximum is IO-feet, side and rear require a 15-foot setback when the property is adjacent to a residential zone. The structures on Lots 12-15 would not have blank walls located in the front yard and would qualify for a reduced setback. Lots 19, 21, and 22 have front facades that have blank walls and so would not qualify for a reduced setback unless the elevations were to be revised. Lots 9, 10, 20, 23 and 24 would have setbacks that are greater than 15-feet, 15-feet is the maximum unless a variance is applied for. A revised site plan will be submitted at the time of building permit application. Almost all lots require some change in facades or placements and so Staff has recommended that the building elevations be revised showing additional architectural detailing on the side yard along a street fa,ade of specific buildings. The applicant submitted a conceptual landscape plan that provides a I 0-foot landscape strip along all street frontages except where the front and side yard along a street setbacks are proposed to be reduced. The sidewalks required along the new NE 3•<l Court would connect pedestrians out towards Bremerton Avenue NE, a 5-foot pedestrian access easement on the northeast portion of the site would connect pedestrians to the north and east property lines, and a pedestrian connection located on the southeast portion of the site would connect pedestrians to the Laurelhurst Division 3 Preliminary Plat to the south. However, after looking at the approved site plan, it appears that a pedestrian connection to the east would terminate in someone's backyard. Bremerton Townhomes Preli. ry Plat File No.: LUA-06-133, PP, CU-A, SA-A, ECF January 8, 2007 Page 4 The Examiner mentioned the earlier hearing and the concerns for the pedestrian connection being proposed through the property to the south. Each proposed townhome has proposed 2 parking spaces each within a private garage. Since compact parking stalls are required it would be required for the applicant to submit a revised site plan showing a maximum of 1 compact parking stall within the private garages proposed for Lots 1-6. Regarding refuse and recycle areas, the duplex structures are exempt from having common collection points, however, code does not exempt the triplex structures. Staff recommends that if Waste Management agrees, the applicant would be required to request a modification from the standard. A request by Staff has asked that there be some modifications to some of the buildings. All elevations be revised to provide weather protection over all secondary entrances as well as the primary entrances, some additional modulation and detailing or change of materials be provided on some of the facades that have less detailing. It was also asked that the weather protection over the entrances to the two triplex buildings (G-H) be revised to mimic the materials and shape of the roof. James Jaeger, 9419 S 204th Place, Kent, WA 98031 stated that they were in agreement with all conditions. In some cases they will revise the building locations for setbacks, in other cases they will revise the elevations. A lot of the areas that are requiring additional details are on the first floor on the back of the garages. There is flexibility to add windows and other things to the back of the garage. On the east side of the plat is the Hillcrest Townhomes, they were permitted with a different owner as a multi- family apartment. To the west is the Ridgeview Court subdivision, detached single-family housing located in the CA zone. To the north is the US Bank and to the south is the Laurelhurst Division 3 application, single- family detached. The depression that runs along the north side of the property has existed on the property for many years. When Bremerton Avenue was constructed any outlet to the west was blocked off. There is no culvert under Bremerton Avenue. When the apartment project was approved, they were issued a grading permit and the site work was done. The grade was raised and the overflow was blocked off and it then flowed to the east onto Duvall. Last winter a small lake was created along the property line. The soils are very pervious, and once the rain stopped the lake was gone within a couple of weeks, leaving behind a depression. All the drainage from the US Bank site drains into that depression. A solution has been worked out with an offsite pipe to Duvall Avenue that will accommodate both this project an US Bank. The depression will then be filled. He did not feel that a through roadway would be beneficial. There is a definite use change between Laurelhurst Division 3 and this project. It would be better for both developments if the pedestrian access were to remain but a road did not go through. Rob Stevens, Core Design, 14711 NE 29th Place, Ste. 101, Bellevue, WA 98007 stated that they were in strong opposition to the walkway heading south on this proposed project. The code does state that pedestrian access is required on each property line, however, the Code 4-3-040F actually states that "a minimum of one pedestrian connection shall be provided from each side of a property or development." There seems to be room for interpretation. There is a 15-foot building setback line and a 15-foot landscape buffer required between zones and densities of such varying differences. This is to provide separation. · Bremerton Townhomes Prelim.uary Plat File No.: LUA-06-133, PP, CU-A, SA-A, EC!' January 8, 2007 Page 5 Additionally, there is an issue with the recreation open space being used by multiple parties outside of the homeowners association of the Laurelhurst project. The staff report for the Bremerton Townhomes, it states that the proposal does not provide on-site recreation areas for future residents of the proposed plat. However, pedestrian trail easements would connect to prope11ies to the north, east and south. There are no existing recreational facilities in the immediate vicinity of the subject property. The Examiner stated that the report should state that, "there are no public recreational uses in the immediate vicinity of the subject property." Kayren Kittrick, Development Services stated that a pedestrian access at this location on the south end also allows the property owners from the south access to the 41 " Street corridor to the shopping and other neighborhoods in this area. Regarding the waterline, there needs to be provisions for all connections, it currently goes to the south property line and if necessary there would be a connection for the townhomes to the east. It does not have to go south for the Laurelhurst Division 3 development. The Examiner called for further testimony regarding this project. There was no one else wishing to speak, and no further comments from staff. The hearing closed at I 0:48 am. FINDINGS. CONCLUSIONS & RECOMMEND A TTON Having reviewed the record in this matter, the Examiner now makes and enters the following: FINDINGS: 1. The applicant, Mark Rousso, Seattle Redevelopment, filed a request for a Preliminary Plat, Conditional Use Permit and Site Plan for a 26-lot townhomc project. 2. The yellow file containing the staff report, the State Environmental Policy Act (SEPA) documentation and other pertinent materials was entered into the record as Exhibit # l. 3. The Environmental Review Committee (ERC), the City's responsible official issued a Determination of Non-Significance -Mitigated (DNS-M). 4. The subject proposal was reviewed by all departments with an interest in the matter. 5. The subject site is located at 320 and 330 Bremerton Avenue NE. The subject site is located on the east side of Bremerton and just south of NE 4th Street. 6. The map element of the Comprehensive Plan designates the area in which the subject site is located as suitable for the development of commercial uses associated with commercial corridors, but does not mandate such development without consideration of other policies of the Plan. 7. The subject site is currently zoned CA (Commercial Arterial). 8. The subject site was annexed to the City with the adoption of Ordinance 4470 enacted in August 1994. Bremerton Townhomes Pre!, ary Plat File No.: LUA-06-133, PP, CU-A, SA-A, ECF January 8, 2007 Page 6 9. The subject site is approximately 76,466 square feet or 1.8 acres. The subject site is an L-shaped parcel that is approximately 294 feet deep (east to west) by 329 feet long. The site has approximately 215 feet of frontage along Bremerton. I 0. There are two homes and some outbuildings located on the subject site. These structures would be removed if the proposal were approved. 11. The subject site is essentially level with a depression located along the northern portion of the subject site. Although the City's critical areas maps show a stream on or near the subject site, a stream assessment determined that the depression is not a stream but is the result of grading in the area. 12. There are 44 significant trees located on the subject site. It has been determined that 25% or eleven (11) of those trees should be retained or replaced. The applicant proposes retaining 5 trees, which would mean that 6 trees would need to be replaced. 13. The applicant would subdivide the existing property into 26 lots that will accommodate attached townhomes in two 3-unit clusters and 10 2-unit clusters. The development of residential uses without a commercial component in the CA Zone requires a Conditional Use Permit. The development also requires Site Plan review. 14. There will be a new public street that runs east from Bremerton and ends in a modified T-intersection. Townhome lots would be located north and south of the road and east of the T-intersection. The two 3- unit townhomes would be located in the southeast panhandle while the remaining 2-unit homes would occupy the rest of the property. The townhomes would be oriented toward the street and toward each other. The proposed lots would range in size from approximately 1,316 square feet to 4,333 square feet. Most of the lots would be rectangular but street curves would define some of the lots. 15. The applicant and staff analyzed a number of road and alley configurations but safety considerations generally dictated the location of NE 3rd Court. Transportation staff preferred that NE 3rd Court generally line up with its counterpart west of Bremerton. There will be easements into some of the properties and direct access to NE 3rd Court. Development within the NE 4th Street District is required to provide links to and through property abutting its property lines to connect residential and commercial development. Those connections are provided along the north and northeast comer of the site. Staff has recommended that the applicant provide an extension of NE 3rd Court to the south property line to provide access through the site to property to the south being proposed for subdivision at this time. The developer of that southerly abutting property objects to that extension. 16. There are additional criteria for stand-alone residential uses in the NE 4th Street Business District. The housing must be at least 150 feet from an arterial street, there is a mix of commercial, residential and service uses within 150 feet of the proposed use, commercial use of the property is not feasible due to configuration or commercial frontage, residential uses are connected to the commercial sectors and there is a transition between the commercial and R-8 districts. The proposed use is located more than 150 feet from NE 4th Street. The site is located within 150 feet of commercial uses. The applicant contends that the site and frontage of the site is unsuitable for commercial uses and staff has recommended a pedestrian connection to the R-8 property to the south of the subject site. 17. The CA zone coupled with the NE 4th Street Corridor regulations permit a front yard between IO feet and 15 feet although it may be reduced as long as there are no blank walls ( 6 feet high and 15 feet long) presented to passersby. Similarly, the side yard is required to be JO feet along a street but may be reduced under similar limitations. A 15 foot rear or side yard is required abutting residential wning · Bremerton Townhomes Prelimu,ary Plat File No.: LUA-06-133, PP, CU-A, SA-A, ECF January 8, 2007 Page 7 such as that found south of the site. The front yard depth may not be exceeded. Staff noted that Proposed Lots I to 8, 11, 16 to 18, 25 and 26 all have the required 10 to 15 foot setbacks. Proposed Lots 12 to 15, 19, 21 and 22 have front yards ofless than 10 feet but of those lots, Lots 19, 21 and 22 have blank walls that will need modifications to meet code. Proposed Lots 9, 10, 20, 23 and 24 have front yards that exceed the maximum 15-foot setback permitted. They will have to be modified to meet code. Proposed Lots I, 3 to 11, 13, 15, 19, 21 to 24 and 26 have side yards along a street or easement. Of those Proposed Lots 13, and 21 to 23 have blank walls and their exterior will have to be modified to meet code. Proposed Lots 15 and 16 abut a residential zone and must be have a 15-foot setback. 18. The applicant had proposed a pedestrian connection to the east near the south comer of the site. This easement would abruptly end at a third party property and not serve any purpose. Staff recommended that it be merged with required landscaping to provide appropriate screening for the abutting R-8 property. 19. The CA zone permits 35-foot tall residential buildings and those proposed for the subject site will be 29 feet tall. 20. The applicant has proposed providing compact parking stalls for Proposed Lots I to 6 but code would not permit more than one compact stall per unit. The plans will have to be modified to meet code. 2 I. The density permitted for residential uses in the CA Zone ranges from 10 to 20 units per acre. The density for the 26 lots would be 19.85 dwelling units per acre after subtracting private easements and public roadways. 22. The subject site is located within the Renton School District. The project is expected to generate approximately 11 school age children. These students would be spread across the grades and would be assigned on a space available basis. 23. The development will increase traffic approximately 5.86 trips per multifamily unit or approximately 133 trips for this plat. Approximately ten percent of the trips, or approximately 13 additional peak hour trips will be generated in the morning and evening. 24. Stormwater would be handled by a detention vault and wet vault that would be located near the southeast comer of the property. 25. Sewer and water service will be provided by the City. Fire flow requirements, hydrant placement and utility line placements will be determined by the various units and their placement. 26. The applicants testified that the site would not be suitable for commercial uses due to the location of the property. CONCLUSIONS: First, before considering the various aspects of this proposal, this office has to note that it reluctantly supports the proposal after some modifications are submitted back to staff for review and then this office. The City specifically reclassified the zoning of this site to Commercial Arterial zoning. The site is part of a CA district that lies both north and south of NE 4th Street. The zone was primarily intended for commercial uses but permits residential uses although generally when combined in a mixed-use development. It does permit solely residential use to usurp the land when there are substantial obstacles, that is, as the code suggests when Bremerton Townhomes Preh, ary Plat File No.: LUA-06-133, PP, CU-A, SA-A, ECF January 8, 2007 Page 8 "Commercial use of the property is not feasible for reasons including, but not limited to: lack of commercial frontage, lack of access, critical areas and/or critical area buffers, or property configuration." (Section 4-9-030.K). The site is almost two acres in size, almost level and generally rectangular. Granted this site is not directly on NE 4th Street but many other parcels in the areas north and south of NE 4th Street do not lie directly on that street. Not all business requires "commercial frontage." While many businesses attract patronage from mere passersby, many other businesses attract a different patronage. Accountants, lawyers, doctors, general offices and similar uses do not necessarily need commercial exposure. In addition, while the City encourages density, the applicant has pushed the property to its limit by achieving a density of 19.85 units per acre but with that they have arranged lots and the dwellings such that many of the lots do not currently meet the standards of the CA Zone and the overlay district. In many cases they have reduced the front yards or street side yards substantially. Staff has had to recommend that a number oflots or the location or style of the housing be redesigned to comply with the platting standards and the design criteria of the CA Zone and the Business Corridor standards. It clearly is a judgment call as to whether the applicant has pushed the standards too far for this project. In order to forward the plat aspect of this proposal to the City Council this office will have to be shown that the modifications requested by Staff can be accommodated. Plat I. If one presumes that the existing property is not suitable for commercial use then it might be reasonable to subdivide the property for residential use. Following that presumption, the proposed plat appears to serve the public use and interest. The redevelopment of the subject site will increase the tax base of the City and provide opportunities for ownership of small, actually, very small lots by individuals. 2. The lots are in the main rectangular and they meet code requirements for size. The lot sizes should also reflect the design standards for residential uses in the CA Zone and Proposed Lots 21 and 22 place homes on those lots too close to the street. It appears that the lot lines between Proposed Lots 21 and 22 and 23 and 24 could be shifted to provide additional street setbacks for Lots 21 and 22. If that is not possible, then one or both of those lots should be eliminated providing larger lots for the remaining homes in the cluster of Lots 19 to 26. The applicant will have to modify some of the proposed layouts to provide code mandated parking, setbacks and as noted below, design features as a tradeoff for developing small lot townhomes. 3. The access appears reasonable and has been designed to create a more regular intersection with Bremerton. Sidewalks as well as the mandated connections to surrounding property have been provided. This office will not hesitate to suggest that a regular width public street to serve these small townhomes seems like overkill and reducing the street width could free land for more substantial setbacks. 4. The applicant will have to meet landscaping requirement for the lots including landscaping on each lot and along street fronts. 5. Public services are available to serve the site and the ERC imposed conditions to offset some of the additional impacts related to redevelopment of the site. 6. In conclusion, once the applicant has submitted appropriate modifications for review by staff and this office, the City Council should approve the proposed Preliminary Plat subject to conditions noted below. Bremerton Townhomcs Prelin ,. dry Plat File No.: LUA-06-133, PP, CU-A, SA-A, ECF January 8, 2007 Page 9 Conditional Use Permit 7. The applicant for a Conditional Use Permit must demonstrate that the use is in the public interest, will not impair the health, safety or welfare of the general public and is in compliance with the criteria found in Section 4-31-36 (C) which provides in part that: a. The proposal generally conforms to the Comprehensive Plan; b. There is a general community need for the proposed use at the proposed location; c. There will be no undue impacts on adpcent property; d. The proposed use is compatible in scale with the adjacent residential uses, if any; e. Parking, unless otherwise permitted, will not occur in the required yards; f. Traffic and pedestrian circulation will be safe and adequate for the proposed project; g. Noise, light and glare will not cause an adverse affect on neighboring property; h. Landscaping shall be sufficient to buffer the use from rights-of-way and neighboring property where appropriate; and 1. Adequate public services are available to serve the proposal. Subject to the reservations outlined in the opening conclusion, the requested conditional use appears justified. 8. The comprehensive plan suggests that the site be developed with commercial uses although the CA zone does permit residential development both as part of a mixed use development and, after meeting certain specifications, as stand-alone residential. This office has already noted the issues related to this criterion. 9. There always seems to be a need for housing. There also appears to be a demand for small lot and townhome layouts either for those looking for their first opportunity for homeownership or those looking to shrink their households. Of course, usurping land that could serve commercial development might not always be the best way to satisfy this need. Housing at this location makes access to commercial uses easier and walking to community shopping is possible. 10. There should not be any undue impacts on adjacent uses. Hopefully, the adjacent commercial uses do not generate too much noise as residents might complain placing pressure on those commercial uses. 11. The townhomes are low-scale and should not adversely affect adjacent residential uses. They are generally no taller than single-family homes. 12. Parking, once the applicant meets the required complement of compact/regular stalls, will be appropriate. Bremerton Townhomes Preli ry Plat File No.: LUA-06-133,PP, CU-A, SA-A, ECF January 8, 2007 Page 10 13. The applicant redesigned the access street to create a more regular four-way intersection with Bremerton. The applicant has created an appropriate grid system for pedestrians to the south of the project in lieu of an unneeded vehicular connection to the south. Such a connection will allow both adults and minors to walk north and south from residential areas to commercial areas without having to walk along a larger street. 14. The applicant will be meeting the landscaping requirements of Code. Staff recommended that the landscaping along the south margin of the site meet the code requirements to buffer the single family zoning south of the site. 15. There are adequate utilities to serve the subject site. Site Plan and Business Corridor Requirements 16. The site plan ordinance provides a number of specific criteria for reviewing a site plan. Those criteria are generally represented in part by the following enumeration: a. Conformance with the Comprehensive Plan; b. Conformance with the Building and Zoning Codes; c. Mitigation of impacts on surrounding properties and uses; d. Mitigation of the impacts of the proposal on the subject site itself; e. Conservation of property values; f. Provision for safe and efficient vehicle and pedestrian circulation; g. Provision of adequate light and air; h. Adequacy of public services to accommodate the proposed use; In addition, as discussed above there are additional criteria for stand-alone residential uses in the NE 4th Street Business District. The housing must be at least 150 feet from an arterial street, there is a mix of commercial, residential and service uses within 150 feet of the proposed use, commercial use of the property is not feasible due to configuration or commercial frontage, residential uses are connected to the commercial sectors and there is a transition between the commercial and R-8 districts. The proposed use, subject to conditions recommended by staff, satisfies these and other particulars of the ordinance. 17. The proposal's compatibility with the comprehensive plan and the Zoning Code have been discussed above. Compliance with the Building Code and Fire Code will be determined when formal applications are submitted. 18. The development of the subject site should not have any adverse impacts on adjacent property outside of the short-term impacts of construction. · Bremerton Townhomes Prelin . ry Plat File No.: LUA-06-133, PP, CU-A, SA-A, ECF January 8, 2007 Page 11 19. The proposed plat does appear to push the density of the plat by achieving almost its maximum, which leads to smaller yards and potential crowding. The modifications suggested by this office and staff to provide the required design elements should help offset some of those impacts, as should the addition of landscaping along the streets. All lots shall provide street landscaping as well as landscaping in the front yards. The applicant shall either increase the street setback for Proposed Lots 21 and 22 as proposed above or eliminate one or both of those lots. Those homes are located too close to the street and design elements alone will not afford appropriate relief to provide quiet residential living to homes located that close to a public street. Even easement access requires reasonable setbacks of homes from the easements. The CA zoning is not an excuse for substandard setbacks and substandard residential amenities. 20. The redevelopment of the subject site should not adversely affect property values. 21. The access and pedestrian connections appear to provide reasonable circulation to and within the subject site. The link to the south appears reasonable and is required by code. 22. The two-story townhomes are close to one another but their limited height should not impair air or light. 23. The subject site appears to have reasonable access to sewer and water services. 24. The proposed use appears to satisfy the criteria for residential use in the NE 4th Street Business Corridor subject to the conditions recommended by staff. The applicant will have to submit plans that show that the site can meet all of those requirements including new elevations that meet the criteria specified by staff. The proposed use is located more than 150 feet from NE 4th Street. The site is located within 150 feet of commercial uses. As already noted the suitability of the site for residential uses as opposed to commercial uses could be considered problematic. Staff has recommended a pedestrian connection to the R-8 property to the south of the subject site. RECOMMENDATION: The City Council should approve the Preliminary Plat subject to the following conditions: I. The applicant shall comply with all requirements of the Determination of Non-Significance -Mitigated that was issued by the Environmental Review Committee on November 20, 2006. 2. Demolition permits shall be obtained and all inspections completed on the demolition of the existing residences and detached accessory structures prior to final plat approval. 3. "No Parking" signage shall be placed along the private access easement that extends off of the southern terminus of NE 3rd Court and serves the two triplex structures. 4. A homeowner's association shall be created concurrently with the recording of the final plat in order to establish maintenance responsibilities for shared roadway, stormwater and utility improvements. A draft of the document(s) shall be submitted to the City of Renton Development Services Division for review and approval by the City Attorney and Property Services section prior to the recording of the final plat. 5. The preliminary plat map shall be revised to extend the private access easement located off of the southern terminus of NE 3rd Court to the southern property line. A revised preliminary plat map shall Bremerton Townhomes Preli ary Plat File No.: LUA-06-133, PP, CU-A, SA-A, ECF January 8, 2007 Page 12 be submitted with the Utility Construction Permit application to the Development Services Division project manager for review and approval. 6. A Tree Retention and Replacement Plan shall be submitted with the Utility Construction Permit Application to the Development Services Division project manager for review and approval. The plan shall detail tree protection measures to be implemented to ensure survival of retained trees and shall include a planting plan showing the species and location of replacement trees. 7. Either the building elevations shall be revised showing additional architectural detailing on the front facades of the buildings proposed to be located on Lots 19, 21, and 22 such that the facades would no longer qualify as blank walls, or the site plan shall be revised to provide a minimum I 0-foot front yard setback for the structures proposed on Lots 19, 21, and 22. The revised elevations or site plan shall be submitted to the Development Services Division project manager and the Hearing Examiner before reviewing by the City Council. 8. A revised site plan shall be submitted to the Development Services Division project manager and Hearing Examiner providing a 15-foot maximum front yard setback for the structures proposed on Lots 9, 10, 20, 23, and 24. 9. Either the building elevations shall be revised showing additional architectural detailing on the side yard along a street facades of the buildings proposed to be located on Lots 13, and 21-23 such that the facades would no longer qualify as blank walls, or the site plan shall be revised to provide a minimum JO-foot front yard setback for the structures proposed on Lots 13, and 21-23. The revised elevations or site plan shall be submitted to the Development Services Division project manager and Hearing Examiner for Lots 13, and 21-23. 10. A revised landscape plan shall be submitted with the building permit application for Lot 15 to the Development Services Division project manager for review and approval. The revised landscape plan shall replace the proposed I 0-foot sight-obscuring landscape strip with a 15-foot wide landscaped visual barrier along the southern property line. 11. A revised preliminary plat map shall be submitted to the Development Services Division project manager and Hearing Examiner for review and approval prior to the approval of the plat. The revised preliminary plat shall show the removal of the proposed 5-foot pedestrian access easement along the southern property line connecting to the property to the east. 12. The site plan shall be revised to include a maximum of 1 compact parking stall within the private garages of proposed Lots 1-6. The revised site plan shall be submitted to the Development Services Division project manager and Hearing Examiner for review and approval for Lots 1-6. 13. A modification to the Refuse and Recyclable Deposit Area regulations shall be submitted with the building permit applications for the triplex structures. The modification shall request the exemption of these structures from the common collection area requirements of this section if Waste Management determines that common collection areas would not be required. The modification request shall address the criteria outlined in RMC 4-9-250D. 14. Revised building elevations shall be submitted at the time of building permit application to the Development Services Division project manager for review and approval. The revised building elevations shall show a minimum of 4 Y, feet of weather protection over each side and rear secondary pedestrian entry, additional plane changes or material variation along the base of the front fa9ade of °Bremerton Townhomes Prelim, . ry Plat File No.: LUA-06-133, PP, CU-A, SA-A, ECF January 8, 2007 Page 13 Building A and the rear facades of Buildings B-F. The weather protection proposed over the primary entrances to Buildings G-H shall be revised to mimic the pitch and materials used on the roofs, and the rear fa~ade of Buildings J & K require additional modulation and articulation. DECISION: The Conditional Use Permit and Site Plan are approved subject to the following conditions: I. The applicant shall comply with all requirements of the Determination of Non-Significance -Mitigated that was issued by the Environmental Review Committee on November 20, 2006. 2. Demolition permits shall be obtained and all inspections completed on the demolition of the existing residences and detached accessory structures prior to final plat approval. 3. "No Parking" signage shall be placed along the private access easement that extends off of the southern terminus of NE 3rd Court and serves the l\vo triplex structures. 4. A homeowner's association shall be created concurrently with the recording of the final plat in order to establish maintenance responsibilities for shared roadway, stormwater and utility improvements. A draft of the document(s) shall be submitted to the City of Renton Development Services Division for review and approval by the City Attorney and Property Services section prior to the recording of the final plat. 5. The preliminary plat map shall be revised to extend the private access easement located off of the southern terminus of NE 3rd Court to the southern property line. A revised preliminary plat map shall be submitted with the Utility Construction Permit application to the Development Services Division project manager for review and approval. 6. A Tree Retention and Replacement Plan shall be submitted with the Utility Construction Permit Application to the Development Services Division project manager for review and approval. The plan shall detail tree protection measures to be implemented to ensure survival of retained trees and shall include a planting plan showing the species and location ofreplacement trees. 7. Either the building elevations shall be revised showing additional architectural detailing on the front facades of the buildings proposed to be located on Lots 19, 21, and 22 such that the facades would no longer qualify as blank walls, or the site plan shall be revised to provide a minimum I 0-foot front yard setback for the structures proposed on Lots 19, 21, and 22. The revised elevations or site plan shall be submitted to the Development Services Division project manager and the Hearing Examiner before reviewing by the City Council. 8. A revised site plan shall be submitted to the Development Services Division project manager and Hearing Examiner providing a 15-fool maximum front yard setback for the structures proposed on Lots 9, 10, 20, 23, and 24. 9. Either the building elevations shall be revised showing additional architectural detailing on the side yard along a street facades of the buildings proposed to be located on Lots 13, and 21-23 such that the facades would no longer qualify as blank walls, or the site plan shall be revised to provide a minimum I 0-foot front yard setback for the structures proposed on Lots 13, and 21-23. The revised elevations or Bremerton Townhomes Preli ry Plat File No.: LUA-06-133, PP, CU-A, SA-A, ECF January 8, 2007 Page 14 site plan shall be submitted to the Development Services Division project manager and Hearing Examiner for Lots 13, and 21-23. 10. A revised landscape plan shall be submitted with the building permit application for Lot 15 to the Development Services Division project manager for review and approval. The revised landscape plan shall replace the proposed 10-foot sight-obscuring landscape strip with a 15-foot wide landscaped visual barrier along the southern property line. 11. A revised preliminary plat map shall be submitted to the Development Services Division project manager and Hearing Examiner for review and approval prior to the approval of the plat. The revised preliminary plat shall show the removal of the proposed 5-foot pedestrian access easement along the southern property line connecting to the property to the east. 12. The site plan shall be revised to include a maximum of 1 compact parking stall within the private garages of proposed Lots 1-6. The revised site plan shall be submitted to the Development Services Division project manager and Hearing Examiner for review and approval for Lots 1-6. 13. A modification to the Refuse and Recyclable Deposit Area regulations shall be submitted with the building permit applications for the triplex structures. The modification shall request the exemption of these structures from the common collection area requirements of this section if Waste Management determines that common collection areas would not be required. The modification request shall address the criteria outlined in RMC 4-9-250D. 14. Revised building elevations shall be submitted at the time of building permit application to the Development Services Division project manager for review and approval. The revised building elevations shall show a minimum of 4 Yi feet of weather protection over each side and rear secondary pedestrian entry, additional plane changes or material variation along the base of the front fa9ade of Building A and the rear facades of Buildings B-F. The weather protection proposed over the primary entrances to Buildings G-H shall be revised to mimic the pitch and materials used on the roofs, and the rear favade of Buildings J & K require additional modulation and articulation. 15. The lot lines between Proposed Lots 21 and 22 and 23 and 24 could be shifted to provide additional street setbacks for Lots 21 and 22. If that is not possible, then one or both of those lots should be eliminated providing larger lots for the remaining homes in the cluster of Lots 19 to 26. 16. The applicant shall submit modified plans that satisfy the conditions imposed by staff and staff shall review those plans and make a final recommendation on their suitability to the Hearing Examiner. ORDERED THIS g<h day of January 2007. HEARING EXAMINER 'Bremerton Townhomes Preli y Plat File No.: LUA-06-133, PP, CU-A, SA-A, ECf January 8, 2007 Page 15 TRANSMITTED THIS 8'h day of January 2007 to the parties of record: Jill Ding 1055 S Grady Way Renton, WA 98055 Rob Stevens Core Design 14711 NE 29tl' Place, Ste. 101 Bellevue, WA 98007 Alice Knight Trustee for Violet Bliss Estate 330 Bremerton Avenue NE Renton, WA 98059 Kayren Kittrick Development Services Division City of Renton Eric LaBrie ESM Consulting Engineers 33915 I" Way S., Ste. 200 Federal Way, WA 98003 Charles Ratzsch 320 Bremerton Avenue NE Renton, WA 98059 TRANSMIITED THIS 8'h day of January 2007 to the following: Mayor Kathy Keolker Stan Engler, Fire James Jaeger 9419 S 204"' Place Kent, WA 9803 I Marc Rousso Seattle Redevelopment LLC PO Box 2566 Renton, WA 98056 Jay Covington, Chief Administrative Officer Julia Medzegian, Council Liaison Gregg Zimmerman, PBPW Administrator Alex Pietsch, Economic Development Jennifer Henning, Development Services Stacy Tucker, Development Services King County Journal Larry Meckling, Building Official Planning Commission Transportation Division Utilities Division Neil Watts, Development Services Janet Conklin, Development Services Pursuant to Title N, Chapter 8, Section lOO(G) of the City's Code, request for reconsideration must be ftled in writing on or before 5:00 p.m., January 22, 2007. Any aggrieved person feeling that the decision of the Examiner is ambiguous or based on erroneous procedure, errors of law or fact, error in judgment, or the discovery of new evidence which could not be reasonably available at the prior hearing may make a written request for a review by the Examiner within fourteen (14) days from the date of the Examiner's decision. This request shall set forth the specific ambiguities or errors discovered by such appellant, and the Examiner may, after review of the record, take further action as he deems proper. An appeal to the City Council is governed by Title IV, Chapter 8, Section 110, which requires that such appeal be filed with the City Clerk, accompanying a filing fee of$75.00 and meeting other specified requirements. Copies of this ordinance are available for inspection or purchase in the Finance Department, first floor of City Hall. Ao appeal must be filed in writing on or before 5:00 p.m., January 22, 2007. If the Examiner's Recommendation or Decision contains the requirement for Restrictive Covenants, the executed Covenants will be required prior to approval by City Council or final processing of the file. You may contact this office for information on formatting covenants. The Appearance of Fairness Doctrine provides that no ex parte (private one-on-one) communications may occur concerning pending land use decisions. This means that parties to a land use decision may not communicate in private with any decision-maker concerning the proposal. Decision-makers in the land use process include both the Hearing Examiner and members of the City Council. Bremerton Townhomes Pre .. nary Plat File No.: LUA-06-133, PP, CU-A, SA-A, ECF January 8, 2007 Page 16 All communications concerning the proposal must be made in public. This public communication permits all interested parties to know the contents of the communication and would allow them to openly rebut the evidence. Any violation of this doctrine would result in the invalidation of the request by the Court. The Doctrine applies not only to the initial public hearing but to all requests for Reconsideration as well as Appeals to the City Council. Project Location: 320 & 330 Bremerton Avenue NE 0 ~ C D C ---·'.-i,,;;~ a -7-"~ -, -:'.;~.",.,;.. ;1 g-~ ----ill --hi ll -'~c-/''"4, E e-,otion BUILDING G-H REAR Elevation. G-H SIDE E'evotion BUILDING G-H STREET I /8' • I'-() ,;~-• '-o· 1/8" • 1·-0· lo I, 1,· 1, •. I, I. I, "' I, I, I, I,. Elevct,on BUILDING & L REAR Elevation: I & L SIDE 11a· ~ ,·_o .. I 'B" • I -0' I, :,. I, l,1 o I. la I,. Elevation BUILDING J & K REAR 1/a· ~ ,·-o· E:cvalion· J & K SIDE I ;8 ~ 1·-0·· lo I. , .. I, I, I~ 1 .. Elev,:Jtion BUILDING & L ST"EET , . 8 ~ ,· -o·· lo 1 , I, ·.:,·:·-·~ :'t ~·-'~ -:•-;c-;c-?: I -:;"cv'-4 . ''-'"~ """" J, --''' -"_,,'I ,,,,.,,~ I ,',,-:-'<' } -::-:.-t'~ Elevation BUILDING J & .'< STREET 1,~· • ,· -o· I, I. 1 ••• I,, ,• (/) 1--u w 1--~ l "' . « < j g I u (/) °' 0 I' , I l· •• ,1: • _. z ,o 1-- 0::: ~ ~ 0 l::l V, J: .. (~0~ F= (/) '<I ~g -, . ...J ...J ..J wm~ (H•O __ " _ __...~II'! II"" ... --_"" __ _ ~"'"'""~""' -··· .. -y-Pointe~"'- Surveying A PORTION of \he N.E. 1/4 & N.W. 1/4, SECTION 15, TOWNSHIP 23 N., RANCE 5 E .. W.f.4. ' ,o• s I a D ' • -AU,a'ltlll'WIIMll',,C. .Ill.I. -.\ ...... #IC ,. -'-.... ,U!lll ____ ff" CJV>. ,, ................ tr'' ,111 •r-.1111:1-•u.a,,,,t:,,1 I fll ......... AC.111: I \1'd.._~ I 1111 '" ,., .... c ...... -, .. ,. -tMblltlol 1t\· 't~ "'--- ~11 .. l r·1 : ~ ~,:.:~ ' ,,,,,,... '"""" si1il'\ ~ ,11 II l ~IUl'HIC SCA&.& isz.;J 'W':z:d-- ~ i ,a,· ..... ,·--~-------•AOC\,. .. ~,, .. ., .... -~--- T'rP. INTFRIOR PLAT ROAD -·- DRAINAGE DETENTION, VAULT Ltll'[l 2 OET£f10N STANDARD suesuRr AC( CONC. VAULT VAULT OIM[NSIONS: es· ii: 42' 11 7.0' OtEP TOP LIO El£V: 408.0 DES.ON 50 \'R, WA1!~ lE\t~ <04.5 BOTTOM WA'T'EA lE\'£L/OUn.Ef: Jt7.S VOi.UM( PACMOED: 2,e,2 er VOLUME REQUIRED: 2~20 er WATER QUAlJTYl \\tTVAULT WETVAUL t BCl.OW OETl:NTION' STORA.Cl: TOP ~TVAULT El.EV. 317.$ eon~ WE:TPONO Elt'YI 21J.s VOI.UMt PRCMDEO: 7Jt2 Ct' Vt:\.UME RECU.ACD: ft.7$0 CF \ltTVAUL T 01MENSl0NS: 88' ,: 21' 11 "4.0' 0£[P ? - 0 z ir ~!di ~~dg wl~~ a:•J I, ... ~ ( 13 ~ 81 I,, e '~ !r §I!! ',_.!,-.~.-'"''"'-~ ~' ·~~-- 1•-1 ·-·· ll, i~ ii 11 I u,i't:iilfN-,,1111 11tl'WUI.T, ~ m ~ <10 i '°" ~ ~ I • ..f.? --:;., Ct~ -'C"k11s· "' •' ___ ..,. --:: 7 "' 410 '°" •o• it::tt .J .~-, ~ ..... 1-" r..:1~,--,--,--,--,-tt::: 406 404 •o• 402 -1-,~,- •oo ·-1-H-l--f-1-1-- +-l=l+R I l Ill I I I Ill bl I 40 , 400 ,,. 1+00 2+00 J+OO J,a 4+00 PROFILE -INJ1R,!j,e,k ~OOP ROAD ~fr I" ... $ ia 111 i~ •• ! ,, 11! •f, 0£VEL'bi>MEN)' PLAN/\ · 1 •;l crrv 01' RENTON " DECO 6 2006 L _.,.. ... RECEIVED =: • ,;--=--. -..1-- • ..L_ .. ' ,(" :..r· ;" . ,· ? /_.,,., ,,, .. ",}·', LEGAL DESCRIPTION Lots 2 and 3, King County Short Plat Number 675015, recorded under recording number 7509050645, in King County, Washington. Citt· .. !lenton Department of Planning I Building IP, .: Works ENVIRONMENTAL & DEVELOPMENT APPLICATION REVIEW SHEET " ·----REVIEWING DEPARTMENT: 1 -,. ,_ APPLICATION NO: LUA06-133 PP, SA-A, CU-A, ECF APPLICANT: Marc Rousso PROJECT TITLE: Bremerton Avenue Townhomes SITE AREA: 1.8 acres LOCATION: 320 & 330 Bremerton Avenue NE COMMENTS DUE: NOVEMBER 10, 2006 DATE CIRCULATED: OCTOBER 27, 2006 PROJECT MANAGBR: Jill Di~ ) PLAN REVIEW: Juliana Fries 11'\ • 1- BUILDING AREA /arossl: 2,200 sauare feet oer unit I WORK ORDER NO: 77667 SUMMARY OF PROPOSAL: The applicant is requesting Preliminary Plat approval, Site Plan approval, Conditional Use Permit approval, and Environmental (SEPA) Review to subdivide an existing 78,466 square foot (1.8 acre) site zoned Commericial Arterial (CA) into 26 lots for the future development of attached townhome units. The proposed lots would range from a minimum of 1,426 square feet to a maximum of 3,337 square feet in area. Two existing residences on the project site are proposed to be removed. Access to the new townhome units would be provided via a new internal public street system. A. ENVIRONMENTAL IMPACT (e.g. Non-Code} COMMENTS Element of the Probable Probable More Element of the Probable Probable More Environment Minor Major Information Impacts Impacts Necessary Environment Minor Major Information Impacts Impacts Necessary Earth Housina Air Aesthetics Water Unht/Glare Plants Recreation Land/Shoreline Use Utilities Animals Trans ation Environmental Health Public Services Energy/ Historic/Cultural Natural Resources Preservation Airport Environment 10,000 Feet 14,000 Feet B. POLICY-RELATED COMMENTS C. CODE-RELATED COMMENTS We have reviewed this application with particular attention to those areas in which we have expertise and have identified areas of probable impact or areas where addWon information is needed to properly assess this proposal. 3-1-02 Signature of Director or Authorized Representative Date 1...,' ',,) *' CITY F RENTON Planning/Building/Public Works Department Gregg Zimmerman P.E:., Administrator -~·\'Y ()~ \ ~ . ; Kathy Keolker, Mayor :;~'iY'tO;,,----------------------------------- December 20, 2006 Eric LaBrie ESM Consulting Engineers 33915 1st Way S ste: #200 Federal Way, WA 98003 Subject: Bremerton Townhomes LUA06-133, PP, CU-A, SA-A Dear Mr. LaBrie: Please find attached comments from our Property Services Section. These comments will aid you in the preparation of the final plat map. If you have any questions regarding the report and decision issued for this short plat proposal, please call me at (425) 430-7219. Sincerely, 71r.zz JillK Q;og u Senior Planner Enclosure cc: Alice Knight, Charles Ratzsch / Owner Marc Rousso / Applicant --------~-----~ 1055 South Grady Way-Renton, Washington 98057 ~ Tl-,-----·---·-···-.~n' ·--··-•-c< __ ,_..;_, ?.nM. ---•~--· ·--· AllE:\D OF THE CURVE DATE: TO: FROM: SUBJECT: CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS MEl\ilORANDUM December 8, 2006 Jill Ding Sonja J. Fesser · 0,\)' pt Bremerton Avenue Townhouses hat, LUA-06-133, PP Format and Legal Description Review Bob Mac Onie and I have reviewed the above referenced preliminary plat submittal and have the following comments: Comments for the Applicant concerning the preliminary plat submittal: The words ELECTRIC and TRANSMJSSIO;s; are misspelled in Item No. 2 under both the "PARCEL 152305 9035" and "PARCEL 1523059193" blocks. Information needed for final plat approval includes the following: Note the City of Renton land use action number and land record number, LUA-OX-XXX-FP and LND-10-045 I, respectively, on the drawing sheets. The type size used for the land record number should be smaller than that used for the land use action number. Please note that the land use action number for the final plat wi II be different from the preliminary plat number and is unknown as of this date. A licensed surveyor will need to prepare and sign the final plat submittal. Note two ties to the City of Renton Survey Control Network. The geometry will be checked by the city when the ties are provided. Note the Basis of Bearing on the final submittal. Include a statement of equipment and procedures used, per WAC 332-130-100. Provide plat and lot closure calculations. Note the date the existing monuments were visited, per WAC 332-130-150, and what was found. \H:\File Sys\LND -Land Subdivision & Surveying Recon!~\LND-10 -Plats.\045 l\RV06 l208.doc December 12, 2006 Page 2 Complete City of Renton Monument Cards, with reference points of all new right-of-way monuments set as part of the plat. Required City of Renton signatures (on the final plat submittal) include the Administrator of Planning/Building/Public Works, the Mayor and the City Clerk. An approval block for the city's Finance Director is also required. Appropriate King County approval blocks need to be noted on the plat drawing. All vested owners of the plat property need to sign the final plat document. Include notary blocks as needed. Include a dedication/certification block on the plat drawing. Indicate what has been, or is to be, set at the corners of the proposed lots. On the final submittal, remove all references to utility facilities, topog lines and other items not directly impacting the subdivision. Remove all references to building setback lines. Setbacks will be determined at the time of issuance of building permits. Remove all references to the "BUILDING COVERAGE TABLE" block. Note encroachments, if any. Note all easements, agreements and covenants of record on the drawing. Note discrepancies between bearings and distances of record and those measured or calculated, if any. The city will provide addresses for the proposed lots after the preliminary plat is approved. The addresses (and street names) will need to he noted on the plat document. Note whether the adjoining properties arc platted (give plat name and lot number) or unplatted. Remove all references to density anJ wning information from the final plat drawing. If there is a Restrictive Covenants, Conditions & Restrictions document for this plat, then reference the same on the plat drawing and provide a space for the recording number thereof. On the drawing, note who is to own and maintain the drainage vault. Note that if there are restrictive covenants, casements or agreements to others (neighboring property owners, etc.) as part of this subdivision, they can be recorded concurrently with the plat. The plat drawings and the associated document(s) are to be given to the Project Manager as a package. The plat document will be recorded l"irst (with King County). The recording number(s) l-L\File Sys\LND -Land Subdivision & Surveyin;:' Rsccord,\LNl)-!0 -Plats\0451\l{V061208.doc\cor December 12, 2006 Page 3 for the associated document(s) (said documents recorded concurrently with, but following the plat) need to be referenced on the plat drawings. The new private access and utilities(?) easements are for the benefit of future owners of the pertinent lots. Since the new lots created via this plat are under common ownership at the time of plat recording, there can be no new easements created until ownership of the lots is conveyed to others, together with/or subject to specific easement rights. Add the following Declaration of Covenant language on the face of the subject plat drawing, if the previous paragraph applies: DECLARATION OF COVENANT The owners of the land embracer/ wirhin rhi, plat, in returnfor the benefit to accrue from this subdivision, by signing hereon cm·enam and agree to convey the beneficial interest in the new easements shoHn m1 this plat to any and al/future purchasers of the lots, or of any subdivisions thereof: l'l1is covenant shall run with the land as shown on this plat. The new private access and utilities (?) easements require a "NEW PRIVATE EASEMENT FOR INGRESS, EGRESS & UTILITIES MAINTENANCE AGREEMENT" statement noted on the plat drawing, or equivalent statement. Sec the attachment. An updated Plat Certificate will be required. Fee Review Comments: The Fee Review Sheet for the preliminary plat review is provided for your use and information. H:\File Sys\LND -L-rnd Subdivision & Survcyini' RecmM,LND-1 () -Plats\0451\R V()(1 I 208.doc\cor Title for both ofthe following paragraphs: NEW PRIVATE EASEMENT FOR INGRESS, EGRESS & UTILITIES MAINTENANCE AGREEMENT Use the following paragraph if there are two or more lots participating in the agreement: NOTE: NEW PRIVATE EXCLUSIVE EASEMENT FOR INGRESS, EGRESS AND UTILITIES IS TO BE CREA TED UPON THE SALE OF LOTS SHOWN ON THIS PLAT. THE OWNERS OF LOTS SHALL HAVE AN EQUAL AND UNDIVIDED INTEREST IN THE OWNERSHIP AND RESPONSIBILITY FOR MAINTENANCE OF THE PRIVATE ACCESS EASEMENT APPURTENANCES. THESE APPURTENANCES AND MAINTENANCE RESPONSIBILITIES INCLUDE THE REPAIR AND MAINTENANCE OF THE PRIVATE ACCESS ROAD, DRAINAGE PIPES, AND STORM WATER QUALITY AND/OR DETENTION FACILITIES WITHIN THIS EASEMENT, PRIVATE SIGN AGE, AND OTHER INFRASTRUCTURE NOT OWNED BY THE CITY OF RENTON OR OTHER UTILITY PROVIDERS. MAINTENANCE COSTS SHALL BE SHARED EQUALLY. PARKING ON THE PAVING IN THE ACCESS EASEMENT IS PROHIBITED, UNLESS PAVEMENT WIDTH IS GREATER THAN 20 FEET. Use the following paragraph if there is one lot subject to the agreement: NOTE: NEW PRIVATE EXCLUSIVE EASEMENT FOR INGRESS, EGRESS AND UTILITIES IS TO BE CREATED UPON THE SALE OF LOTS SHOWN ON THIS PLAT. THE OWNER OF LOT SHALL HAVE OWNERSHIP AND RESPONSIBILITY FOR MAINTENANCE OF THE PRIVATE ACCESS EASEMENT APPURTENANCES. THESE APPURTENANCES AND MAINTENANCE RESPONSIBILITIES INCLUDE THE REPAIR AND MAINTENANCE OF THE PRIVATE ACCESS ROAD, DRAINAGE PIPES, AND STORM WATER QUALITY AND/OR DETENTION FACILITIES WITHIN THIS EASEMENT, PRIVATE SIGN AGE, AND OTHER INFRASTRUCTURE NOT OWNED BY THE CITY OF RENTON OR OTHER UTILITY PROVIDERS. MAINTENANCE COSTS SHALL BE SHARED EQUALLY. PARKING ON THE PAVING IN THE ACCESS EASEMENT IS PROHIBITED, UNLESS PAVEMENT WIDTH IS GREATER THAN 20 FEET. PROPERTY, ;ES FEE REVIEW FOR SUBDIVISJO .2006-0? APPLICANT: :R,ll;fi".BCH I C!::+AB! ES , MABc. ::SO! )S.50 RECEIVED FROM _____ _ (date) JOB ADDRESS: aeo ;& ,3,"30 ::eee-1~ve:. bJE t4<>1--W0#_•~7~G=w~7-----~ NATURE OF WORK: P6 • 1..Cf J Ob !<'j :jv! ~ ('3Rl:Mp~ L')l'.eb)) IE'. :JnWL!-LND # IO -045 I )<; PRELIMINARY REVIEW OF SUBDIVISION ifr LONG PLAT, NEED MORE INFORMATION: -LEGAL DESCRIPTION SHORT PLAT, BINDING SITE PLAN, ETC. PID #'s VICINITY MAP ·· FINAL REVIEW OF SUBDIVISION, THIS REVIEW REPLACES SQUARE FOOTAGE -OTHER PRELIMINARY FEE REVIEW DATED FRONT FOOTAGE SUBJECT PROPERTY PARENT PID# I 52~5 -9J9_;:,__ NEW KING CO. TAX ACCT.#(s) are required when assigned by King County. It is the intent of this development fee analysis to put the developer/owner on notice, that the fees quoted below may be applicable to the subject site upon development of the property. All quoted fees are potential charges that may be due and payable at the time the construction permit is issued to install the on-site and off-site improvements (i.e. underground utilities, street improvements, etc.) Triggering mechanisms for the SDC fees will be based on current City ordinances aIII determined by the applicable Utility Section. Please oote that these fees are subject to change without notice. Final fees will be based on rates in effect at time of Building Penn.it/Construction Pennit al}PlicatiOii. - The existing house on SP Lot # ___ , addressed as has not previously paid ~~--SDC fees, due to connection to City utilities prior to existance of SDC fee Ord. SP Lot# will be subject to future SDC fees if triggering mechanisms are touched within current City Ordinances. We understand that this subdivision is in the preliminary stage and that we will have the opportunity to review it again before recordation. fi Toe ollowmo ouoted fees do NOT mclude insnection fees, side sewer nermits, r/w nennit fees or the cost of water meters. SPECIAL ASSESSMENT DISTRICT PARCEL METHOD OF ASSESSMENT ASSESSMENT DISTRICTS NO. NO. ASSESSMENT UNITS OR FEE Latecomer Al!l"eement (uvt) WATER -o- Latecomer Aoreement lnvt) WASTEWATER -o- Latecomer Al!l"eement lnvt) OTHER -o- / Suecial Assessment District/WATER /-,,._- t=:A;r, 'R~i-. 11-l"fE~~ o-e $ ol.Jo.80X .2.-:: eto ,l; .. ~-SO Sueci Assessment District/W ASTEW AT Joint Use Aoreement (METRO) - Local Imorovement District • - Traffic Benefit Zones $75.00 PER TRIP, CALCULATED BY TRANSPORTATION - FUTURE OBLIGATIONS - SYSTEM DEVELOPMENT CHARGE-WATER ·· Estimated #OF UNITS/ SDCFEE -Pd Prev. ·· Partiallv Pd (Ltd Exemution) -Never Pd SQ. FTG. Sinele familv residential $1,956/unit x ~ ~4G,qM,-,, Mobile home dwelline unit $1,956/nnit in nark Apartment. Condo $1,174/unit not in CD or COR zones x Commercial/Industrial, $0.273/sq. ft. of oro=rtv (not less than $1,956.00) x Boeing, by Special Agreement/Footprint of Bldg plus 15 ft perimeter (2,800 GPM threshold) SYSTEM DEVELOPMENT CHARGE -WASTEWATER .. Estimated -Pd Prev. .. Partially Pd (Ltd Exemotion) -Never Pd Sinele familv residential $1,017/unit x ,:;,,=. $ z.G.44?." h . Mobile home dwellim• unit $1,017/unit x Anartment, Condo $610/unit not in CD or COR zones x Commercial/Industrial $0,142/so. ft. of nronertv x(not less than $1,017.00) SYSTEM DEVELOPMENT CHARGE -SURFACEW ATER .. Estimated -Pd Prev. ·· Partiallv Pd (Ltd Exemotion) .. Never Pd Sin2le familv residential and mobile home dwellim:, unit $759/unit x ~A 11! I"" '°IGO" All other properties $0.26S/sq ft of new impervious area of property x (not less than $7S9.00) T PRELIMINARY TOTAL $ qq,s30= c.x'.) 15'0 ) ~, \ 7i t,ODf i, .-:' ';i " '7~ft:OC-, 0 • 0 " "' Signal of Reing Authority ' --" t *If subject property is within an LID, it is developers responsibility to check with the Finance Dept. for paid/un-paid status. • < .. e- Square footage figur~ are taken from the King County Assessor's map and are subject to change • • • .. Current City SDC fee charges apply to , 0 EFFECTIVE January 8, 2006 City . • ton Department of Planning I Building IP •.. arks ENVIRONMENTAL & DEVELOPMENT APPLICATION REVIEW SHEET REVIEWING DEPARTMENT: . rh:_JC\c",i ·f, J ,<:, ,'( -". APPLICATION NO: LUA06-133, PP .. SA-A, di-A, ECF APPLICANT: Marc Rousso PROJECT TITLE: Bremerton Avenue Townhomes SITE AREA: 1.8 acres LOCATION: 320 & 330 Bremerton Avenue NE COMMENTS DUE: NOVEMBER 10, 2006 DATE CIRCULATED: OCTOBER 27, 2006 PROJECT MANAGER: Jill Dino PLAN REVIEW: Juliana Fries BUILDING AREA lnross\: 2,200 souare feet derunit WORK ORDER NO: 77667 SUMMARY OF PROPOSAL: The applicant is requesting Preliminary Plat approval, Site Plan approval, Conditional Use Permit approval, and Environmental (SEPA) Review to subdivide an existing 78,466 square foot (1.8 acre) site zoned Commericial Arterial (CA) into 26 lots for the future development of attached townhome units. The proposed lots would range from a minimum of 1,426 square feet to a maximum of 3,337 square feet in area. Two existing residences on the project site are proposed to be removed. Access to the new townhome units would be provided via a new internal public street system. A. ENVIRONMENTAL IMPACT (e.g. Non-Code) COMMENTS Element of the Probable Probable More Element of the Probable Probable More Environment Minor Major Information Impacts Impacts Necessary Environment Minor Major Information Impacts Impacts Necessary Earth Housinn Air Aesthetics Water Uaht!Glare Plants Recreation Land/Shoreline Use Utilities Animals Trans""rlafion Environmental Health Public Services Energy/ Historic/Cultural Natural Resources Preservation Airport Environment 10,000 Feet 14,000 Feet 8. POLICY-RELATED COMMENTS C. CODE-RELATED COMMENTS ' We have reviewed this appfication with particular attention to those areas in which we have expertise and have identified areas of probable impact or areas where additional information is needed to properly assess this proposal. Signature of Director or Authorized Representative Date ENVIRONMENTAL REVIEW COMMITTEE MEETING NOTICE November 20, 2006 To: Gregg Zimmerman, Planning/Building/Public Works Administrator Terry Higashiyama, Community Services Administrator I. David Daniels, Fire Chief Alex Pietsch, EDNSP Administrator From: Jennifer Henning, Development Planning Meeting Date: Monday, November 20, 2006 Time: 3:00 PM Location: Sixth Floor Conference Room #620 Agenda listed below. Laurelhurst Division 3 Preliminary Plat (Higgins) LUAOS-131, PP, ECF The proponent of the Laurelhurst Division 3 Preliminary Plat is requesting SEPA environmental review and Preliminary Plat approval for subdivision of 2.4 acres of land into 14 lots suitable for single-family residential development. The property is currently used for a single-family residence. It is zoned Residential 8 (R-8). The lots would be developed at.a density of 7.86 dwelling units per net acre (du/a). The lots would range in size from approximately 4,800 sq ft to 7,700 sq ft. Bremerton Townhomes {Ding) LUAOG-133, CU-A, SA·A, ECF The applicant is requesting Preliminary Plat approval, Site Plan approval, Conditional Use Permit approval, and Environmental (SEPA) Review to subdivide an existing 78,466 square foot (1.8 acre) site zoned Commercial Arterial (CA) into 26 lots for the future development of attached townhome units. The proposed lots would range from a minimum of 1,426 square feet to a maximum of 3,337 square feet in area. Two existing residences on the project site are proposed to be removed. Access to the new townhome units would be provided via a new internal public street system. cc: K. Keolker, Mayor J. Covington. Chief Administrative Officer S. Dale Estey. EDNSP Director® J. Gray, Fire Prevention N. Watts, P/B/PW Development Services Director ® F. Kaufman, Hearing Examiner S. Engler, Fire Prevention ® J. Medzegian, Council P. Hahn, P/8/PW Transportation Systems Director R. Lind, Economic Development L. Warren, City Attorney ® CITY OF RENTON CURRENT PLANNING DIVISION AFFIDAVIT OF SERVICE BY MAILING On the 12'h day of December, 2006, I deposited in the mails of the United States, a sealed envelope containing Preliminary Report to the Hearing Examiner documents. This information was sent to: Name Reoresentina Eric LaBrie Contact Marc Rousso Applicant Alice Knight (Trustee for Violet Bliss Estate) Owner Charles Ratzsch Owner (Signature of Sender) . .:...:· ______________________ _ STATE OF WASHINGTON ss COUNTY OF KING I certify that I know or have satisfactory evidence that Holly Graber ~,\\""'' signed this instrument and acknowledged 1t to be his/her/their free and voluntary acB,Y~~!!,,~ purposes mentioned in the instrument. fr&,"E~~, : ff +OTA~ Dated: 1S).-1;:J.-o(p Arnh,, / ,p::,i'-\c\co&Qrrnr, ; !-o cl-1 . Notary Public 1n and for the Stat~ot~as!lington g i \ .... ,\ v11.,f.J ,~= · -' ~ -~ °".. ........ , .\0 o,-. Notary (Pnnt).Q,, 1'f'-. -,r{ flY>C> WL:l"' 41 >;, ~...;,.'IJ ,L~'E My appointment expires: ---, _ 1 c _ 1,, 111 111 WA. O c L 1\1\\\~ Project Name: Bremerton Avenue Townhomes Project Number: LUA06-133, PP, CU-A, SA-A, ECF ~:· ~ ...-::} ·~·\Y ') CIT . OF RENTON ,~ \~; Kathy Kcolker, Mayor ;,-,, «tO Planning/Building/PublicWorks Department Gregg Zimmerman P.E., Administrator y 1 "' December 12, 2006 Eric LaBrie ESM Consulting Engeineers 33915 1st Way S #200 Federal Way, WA 98003 SUBJECT: Bremerton Avenue Townhomes LUA06-133, PP, CU-A, SA-A. ECF Dear Mr. LaBrie: This letter is to inform you that the appeal period has ended for the Environmental Review Committee's {ERC) Determination of Non-Significance -Mitigated for the above-referenced project. No appeals were filed on the ERG determination. This decision is final. The applicant must comply with all ERG Mitigation Measures outlined in the Report and Decision dated November 20, 2006. A Hearing Examiner Public Hearing has been scheduled for December 19, 2006, where Site Plan Conditions may be issued. The applicant or representative{s) of the applicant are required to be present. Enclosed is a copy of the Preliminary Report to the Hearing Examiner for your review. If you have any questions, please feel free to contact me at (425) 430-7219. For the Environmental Review Committee, (}_j_j 1r P~1 v7fi~ K Ding I/ Senior Planner I/ cc: Alice Knight {Trustee for Viole Bliss Estate), Charles Ratzsch / Owners Marc Rousso / Applicant -------------~ 1055 South Grady Way-Renton, Washington 98057 ~ Thi~"''"'''" rnnb,n~ ~,nu.(, ,,=.r"rl"-" tn,a/.,.n,:,I snWo n=t """"'' ,..,...,, AHF1\0 OF THE CURVE COMMENCING AT 9:00 AM, CITY OF RENTON HEARING EXAMINER PUBLIC HEARING December 19, 2006 AGENDA COUNCIL CHAMBERS, 7TH FLOOR, RENTON CITY HALL The application(s) listed are in order of application number only and not necessarily the order in which they will be heard. Items will be called for hearing at the discretion of the Hearing Examiner. PROJECT NAME: Laurelhurst Div. 3 Preliminary Plat PROJECT NUMBER: LUA06-131, PP, ECF PROJECT DESCRIPTION: The applicant is requesting Preliminary Plat approval for subdivision of a parcel of land totalling 2.4 acres into lots suitable for single-family residential development. The property is located in Northeast Renton, south of NE 4th Street and abutting Bremerton Avenue NE. Access to the plat would be from Bremerton Avenue NE, Chelan Avenue NE and NE 2nd Court, which are all new roads at this location. The land is currently used for one, single-family residential house. The proposed subdivision would create 14 lots, three of which would be comprised of partial lots from an earlier subdivision, Laurelhurst Division 1. The density of the plat would be 7.14 dwelling units per net acre, which is within the range allowed by the Residential 8 zone. PROJECT NAME: Bremerton Avenue Townhomes PROJECT NUMBER: LUA06-133, PP, SA-A, CU-A, ECF PROJECT DESCRIPTION: The applicant is requesting Preliminary Plat approval, Site Plan approval, Conditional Use Permit approval, and Environmental (SEPA) Review to subdivide an existing 78,466 square foot (1.8 acre) site zoned Commercial Arterial (CA) into 26 lots for the future development of attached townhome units. The proposed lots would range from a minimum of 1,316 square feet to a maximum of 4,333 square feet in area. Two existing residences on the project site are proposed to be removed. Access to the new townhome units would be provided via a new internal public street system. HEX Agenda 12-19-06 PUBLIC HEARING City of Renton Department of Planning I Building I Public Works PRELIMINARY REPORT TO THE HEARING EXAMINER A. SUMMARY AND PURPOSE OF REQUEST: Public Hearing Date: Project Name: Applicant: Contact: File Number: Project Description: Project Location: December 19, 2006 Bremerton Townhomes Mark Rousso, Seattle Redevelopment, LLC PO Box 2566, Renton, WA 98056 Eric LaBrie, ESM Consulting Engineers, 33915 1" Way S, ste 200, Federal Way, WA 98003 LUA-06-133, PP, CU-A, SA-A, ECF Project Manager: Jill K. Ding, Senior Planner The applicant is requesting Preliminary Plat approval, Site Plan approval, Conditional Use Permit approval, and Environmental (SEPA) Review to subdivide an existing 78,466 square foot (1.8 acre) site zoned Commercial Arterial (CA) into 26 lots for the future development of attached townhome units. The proposed lots would range from a minimum of 1,316 square feet to a maximum of 4,333 square feet in area. Two existing residences on the project site are proposed to be removed. Access to the new townhome units would be provided via a new internal public street system. 320 & 330 Bremerton Avenue NE City of Renton PIBIPW Depart1 BREMERTON TOWNHOMES Preliminary Report to the Hearing Examiner LUA-06-133, PP, CU-A, SA-A, ECF PUBLIC HEARING DATE: December 19, 2006 Page 2 of 20 B. HEARING EXHIBITS: Exhibit 1: Project file ("yellow file") containing the application, reports, staff comments, and other material pertinent to the review of the project. Exhibit 2: Neighborhood Detail Map Exhibit 3: Preliminary Plat Map (dated revised 12/5/2006) Exhibit 4: Conceptual Drainage and Utility Plan (dated 12/5/2006) Exhibit 5: Grading and Tree Plan (dated 12/5/2006) Exhibit 6: Conceptual Landscape Plan (dated 9/29/2006) Exhibit 7: Elevations Bldg A & B-F (dated 10/6/2006) Exhibit 8: Elevations Bldg G-H, I & L, and J & K (dated 10/6/2006) Exhibit 9: Zoning Map sheet F6 west Y, (dated 2/16/2006) Exhibit 1 O: ERC Mitigation Measures C. GENERAL INFORMATION: 1 . Owners of Record: Alice Knight, Trustee for Violet Bliss Estate, 330 Bremerton Avenue NE, Renton, WA 98059 2. Zoning Designation: Charles Ratzsch, 320 Bremerton Avenue NE, Renton, WA 98059 Commercial Arterial (CA) 3. Comprehensive Plan Land Use Designation: Commercial Corridor (CC) 4. Existing Site Use: Single-family residences to be removed 5. Neighborhood Characteristics: North: Commercial Arterial (CA) zoning East: Commercial Arterial (CA) zoning South: Single family residential; R-8 zoning West: Commercial Arterial (CA) zoning 6. Access: Via proposed internal access road 7. Site Area: 76,466 square feet (1.8 acres) 8. Project Data: Area Comments Existing Building Area: New Building Area: N/A Approx. 2,500 square feet per unit Approx. 65,000 square feet Existing residences to be removed N/A Total Building Area: N/A Hexrpt 06-133.doc City of Renton PIB/PW Depatt BREMERTON TOWNHOMES Preliminary Report to the Hearing Examiner LUA-06-133, PP, CU-A, SA-A, ECF PUBLIC HEARING DATE: December 19, 2006 D. HISTORICAUBACKGROUND: Action Annexation Comprehensive Plan Zoning Land Use File No. N/A N/A N/A Ordinance No. 4470 5099 5191 E. APPLICABLE SECTIONS OF THE RENTON MUNICIPAL CODE: 1. Chapter 2 Land Use Districts Section 4-2-020: Purpose and Intent of Zoning Districts Section 4-2-070: Zoning Use Table Section 4-2-120: Commercial Development Standards 2. Chapter 3 Environmental Regulations and Overlay Districts Section 4-3-040: Commercial Corridor Business Designations Section 4-3-100: Urban Design Regulations 3. Chapter 4 Property Development Standards Section 4-4-030: Development Guidelines and Regulations Section 4-4-060: Grading, Excavation and Mining Regulations Section 4-4-080: Parking, Loading and Driveway Regulations Section 4-4-130: Tree Cutting and Land Clearing Regulations 4. Chapter 6 Streets and Utility Standards Section 4-6-060: Street Standards 5. Chapter 7 Subdivision Regulations Page 3 of 20 Date 8/22/1994 11/01/2004 12/12/2005 Section 4-7-050: General Outline of Subdivision, Short Plat and Lot Line Adjustment Procedures Section 4-7-080: Detailed Procedures for Subdivision Section 4-7-120: Compatibility with Existing Land Use and Plan-General Requirements and Minimum Standards Section 4-7-150: Streets -General Requirements and Minimum Standards Section 4-7-160: Residential Blocks -General Requirements and Minimum Standards Section 4-7-170: Residential Lots-General Requirements and Minimum Standards 6. Chapter 9 Procedures and Review Criteria 7. Chapter 11 Definitions F. APPLICABLE SECTIONS OF THE COMPREHENSIVE PLAN: 1. Land Use Element: Commercial Corridor objectives and policies. 2. Community Design Element. G. DEPARTMENT ANALYSIS: 1. PROJECT DESCRIPTION/BACKGROUND The proposal would result in the construction of 26 attached townhome units on 26 lots. The project would be composed of two 3-unit structures and ten 2-unit structures. The project site is located on the east side of Bremerton Avenue NE and is zoned Commercial Arterial (CA) and is also located within the NE 4th Street Corridor Business District. The proposal for stand along residential within the CA zone requires approval of a Conditional Use Permit. Two existing residences and associated outbuildings are proposed to be removed from the project site. The applicant contends that no critical areas are located on the project site. The City's critical areas maps have identified a Class 4 stream that would be located in the vicinity of the project site; however the applicant has provided a stream study indicating that there is no stream in the vicinity of this site. A Hexrpt 06-133.doc City of Renton PIBIPW Depart BREMERTON TOWNHOMES PUBLIC HEARING DA TE: December 19, 2006 Preliminary Report to the Hearing Examiner LUA-06-133, PP, CU-A, SA-A, ECF Page 4 of 20 low depression is located along the north property line in the vicinity of where the City's maps identify a stream. The depression is approximately 1 O fee: deep and extends off-site to the north. The applicant indicates that the depression was created as a result of grading that was done on the property to the east as apart of a multi-family residential development. The proposal would include filling the depression. A grading easement would be obtained to fill off-site portions of the depression. The project would result in approximately 500 cubic yards of cut and 4,000 cubic yards of fill. The majority of the grading required for the project would be for the excavation of the detention vault and fill for the depression. All cut material is proposed to be used on-site. The existing drainage from the north half of the project site sheet flows across the site and into the depression. The drainage from the south half of the project site sheet flows to the southwest corner of the site. Access to the proposed lots would be provided via a new internal public street off of Bremerton Avenue NE. 2. ENVIRONMENTAL REVIEW Pursuant to the City of Renton's Environmental Ordinance and SEPA (RCW 43.21C, 1971 as amended), on November 20, 2006, the Environmental Review Committee issued a Determination of Non-Significance - Mitigated (DNS-M) for the Bremerton Townhomes project. The DNS-M included 6 mitigation measures. A 14-day appeal period commenced on November 27, 2006 and ended on December 11, 2006. No appeals of the threshold determination were filed. 3. COMPLIANCE WITH ERC MITIGATION MEASURES Based on an analysis of probable impacts from the proposal, the Environmental Review Committee (ERC) issued the following mitigation measures with the Determination of Non-Significance -Mitigated: 1. The applicant shall comply with the recommendations found in the geotechnical report prepared by Earth Solutions NE, LLC, dated July 19, 2006. 2. The applicant shall be required to provide a Temporary Erosion and Sedimentation Control Plan (TESCP) designed pursuant to the Department of Ecology's Erosion and Sediment Control Requirements outlined in Volume II of the Stormwater Management Manual and provide staff with a Construction Mitigation Plan prior to issuance of Construction Permits. This condition shall be subject to the review and approval of the Development Services Division. 3. The detention system for this project shall be required to comply with the requirements found in the 2005 King County Surface Water Design Manual to meet both detention (Conservation Flow control -a.k.a. Level 2) and water quality improvements. 4. The applicant shall pay a Parks Mitigation Fee based on $530.76 per each new single family lot. 5. The applicant shall pay a Traffic Mitigation Fee in the amount of $75 for each new net daily trip prior to the recording of the final plat. It is anticipated that the proposed project would result in the payment of $9,991.50 (152 net new daily trips x $75 = $9,991.50). 6. Staff recommends that the applicant pay a Fire Mitigation Fee based on $388.00 per new single family lot prior to the recording of the final plat. The fee is estimated at $9,312 ($388 x 24 = $9,312). 4. STAFF REVIEW COMMENTS Representatives from various City departments have reviewed the application materials to identify and address site plan issues from the proposed development. These comments are contained in the official file, and the Hexrpt 06-133.doc City of Renton P!B!PW Depart, BREMERTON TOWNHOMES Preliminary Report to the Hearing Examiner LUA-06-133, PP, CU-A, SA-A, ECF PUBLIC HEARING DATE: December 19, 2006 Page 5 of 20 essence of the comments has been incorporated into the appropriate sections of this report and the Departmental Recommendation at the end of the report. 5. CONSISTENCY WITH PRELIMINARY PLAT CRITERIA: Approval of a plat is based upon several factors. The following preliminary plat criteria have been established to assist decision makers in the review of the subdivision: (1) Compliance with the Comprehensive Plan Designation. The subject site is designated Commercial Corridor (CC) on the Comprehensive Plan Land Use Map. The CC areas evolve from "strip commercial" linear business districts to business areas characterized by enhanced_ site planning incorporating efficient parking lot design, coordinated access, amenities, and boulevard treatment. Commercial Corridor areas may include designated districts including concentrations of specialized uses such as the Auto Mall, or features such as transit stops and a combination of businesses creating a focal point of pedestrian activity and visual interest. The proposed plat is consistent with the following Commercial Corridor policies and objectives: Land Use Element Policy LU-353. Structures at Commercial Corridor intersections should not be set back from the street and sidewalk so as to allow vehicular circulation or parking to be located between the sidewalk and the building. No parking is proposed between the sidewalk and the buildings. Community Design Element Policy CD-19: During development, significant trees, either individually or in stands, should be preserved, replaced, or as a last option, relocated. The applicant will be required to retain or replace 25 percent of the significant trees located on- site. Policy CD-22: When appropriate, due to scale, use, or location, on-site open space and recreational facilities in developments should be required. Pedestrian connections are provided to each side of the development proposal where appropriate. Policy CD-45. Existing mature vegetation and distinctive trees should be retained and protected in developments. The applicant submitted a significant tree retention plan and will be required to retain or replace a minimum of 25% of the existing significant trees located onsite. Policy CD-50. Trees should be planted along residential streets, in parking lots requiring landscaping, and in other pervious areas as the opportunity arises. Trees should be retained whenever possible and maintained using Best Management Practices as appropriate for each type. A conceptual landscape plan was submitted with the project application proposing street trees along the proposed access road. In addition, a tree retention plan was also submitted. The applicant will be required to retain or replace a minimum of 25% of the existing significant trees located onsite. (2) Compliance with the Underlying Zoning Designation. The 1. 8-acre site is designated Commercial Arterial (CA) on the City of Renton Zoning Map. The proposed development would allow for the future construction of up to 26 new residential units. Hexrpt 06-133.doc Density -The density range permitted in the Northeast Fourth Corridor Business District portion of the CA zone is a minimum of 10 dwelling units per acre up to a maximum of 20 dwelling units City of Renton PIBIPW Depart1 BREMERTON TOWNHOMES Preliminary Report to the Hearing Examiner LUA-06-133, PP, CU-A, SA-A, ECF PUBLIC HEARING DATE: December 19, 2006 Page 6of 20 Hexrpt 06-133.doc per net acre. Net density is calculated after public rights-of-way, private access easements (vehicular or pedestrian), and critical areas are deducted from the gross acreage of the site. After the deduction of 15,185 square feet of proposed right-of-way dedication and 6,347 square feet of private access easements, the proposal for 26 lots would result in a net density of 19.85 dwelling units per acre (78,466 gross sq. ft. -15,185 sq. ft. -6,347 sq. ft.= 56,934 sq. ft. or 1.31 ac, 26 units/ 1.31 acres= 19.85 du/ac). The proposed plat appears to comply with density requirements for the CA zoning designation. Lot Dimensions and Size -No minimum lot size is required in the CA zone, however within the Northeast Fourth Corridor Business District a minimum lot size of 1,200 sq ft is required. There are no minimum lot width or depth requirements. The proposed plat would create 26 lots with the following sizes: Lot Number Lot Size (square feet) 1 1,525 2 1,560 3 1,920 4 1,680 5 1,680 6 2,539 7 3,102 8 1,846 9 1,978 10 2,394 11 2,174 12 1,835 13 1,674 14 1,316 15 2,315 16 2,707 17 1,522 18 2,095 19 2,072 20 4,333 21 1,487 22 1,968 23 2,245 24 3,903 25 2,551 26 2,060 Access Private Alley Private Alley Private Alley NE 3"' Court NE 3"' Court NE 3"' Court NE 3"' Court NE 3"' Court NE 3"' Court NE 3"' Court NE 3"' Court NE 3"' Court NE 3"' Court Private Street Private Street Private Street Private Street NE 3"' Court Private Access Easement Private Access Easement NE 3"' Court Private Alley Private Access Easement Bremerton Ave NE Private Alley Private Alley As proposed, all lots appear to be in compliance with the required lot width, depth and size standards as prescribed in the CA zone. Setbacks -In the CA zone, the minimum front yard setback is 10 feet and may be reduced down to zero feet through the site plan review process provided no blank walls are located within the reduced setback. In the NE 4th Corridor Business District, the maximum front yard setback permitted is 15 feet. A 10-foot side yard along a street setback is required, which may be reduced down to zero feet through the site plan review process provided no blank walls are located within the reduced setback. A 15-foot side or rear yard setback is required where the property abuts to or is adjacent to a residential zone. The proposed lots appear to contain adequate area for the construction of the proposed townhome structures. See further discussion below under Site Plan Review Criteria. City of Renton P!BIPW Depart1 BREMERTON TOWNHOMES Preliminary Report to the Hearing Examiner LUA-06-133, PP, CU-A, SA-A, ECF PUBLIC HEARING DATE: December 19, 2006 Page 7 of 20 Building Standards -The CA zone and NE 4th Corridor Business District limit the number of attached residential units to 4_ None of the proposed structures would create more than 4 attached residential units. Building height in the CA zone and NE 4th Corridor Business District is limited to 35 feet for residential uses. The proposed structures would have a height of 29 feet, which complies with this requirement. Two existing residences and detached accessory structures are proposed to be removed as a result of the construction of the proposed plat. Staff recommends as a condition of approval that the applicant obtain demolition permits and complete all required inspection prior to the recording of the final plat. The NE 4th Corridor Business District requires that the proposed structures comply with the Urban Design Regulations District B, see discussion further discussion below on the structures compliance with these regulations. Parking -Each dwelling unit is required to provide 1.75 off-street parking stalls per unit. Each proposed unit would provide parking for 2 vehicles within a 2 car garage. The proposed building pads appear to be adequately sized for the provision of the required parking. Landscaping -The City's landscaping regulations require the installation of landscaping. The minimum amount of on-site landscaping required along street frontages is 1 O feet, except where the front or side yard along a street setbacks have been reduced through the site plan review process. Where the property abuts the R-8 zone a 15-foot wide landscaped visual barrier consistent with the definition in RMC 4-11-20 is required. A 10-foot sight-obscuring landscaped strip may be allowed through the site plan review process. The applicant submitted a Conceptual landscape plan with the project application. See landscape discussion below under Site Plan Review Criteria. (3) Compliance with Subdivision Regulations Hexrpt 06-133.doc Lot Arrangement: Side lot lines are to be at right angles to street lines, and each lot must have access to a public street or road. Access may be by private access easement per the requirements of the Street Improvement Ordinance. As proposed, the lots appear to comply with arrangement and access requirements of the Subdivision Regulations. Lots: The size, shape and orientation of lots shall meet the minimum area and width requirements of the applicable zoning classification and shall be appropriate for the type of development and use contemplated. Each of the proposed lots is roughly rectangular in shape, oriented to provide front yards facing a street or private access easement, and satisfies the minimum lot area and dimension requirements of the CA zone and the NE 4th Street Corridor Business District. When considering the required setbacks, as well as access points for each lot, the proposed lots appear to have sufficient building area for the development of townhomes. Property Corners at Intersections: All lot corners at intersections of dedicated public rights-of- way, except alleys, shall have minimum radius of 15 feet. Access and Street Improvements: Access to the site is proposed via a new internal access (NE 3"' Court) road off of Bremerton Avenue NE. Full street improvements including curb, gutter, sidewalk, and street lighting are required on the new internal public street (NE 3"' Court) and along Bremerton Avenue NE. In order to ensure efficient emergency access to the development is not obstructed, staff recommends as a condition of preliminary plat approval the applicant be required to place "No Parking" signage along the private access easement, which extends off of the southern terminus of the proposed public right-of-way serving the three attached units. In addition, staff recommends a condition of approval requiring the establishment of a homeowner's association for the development, which would be responsible for any common improvements and/or tracts within the plat prior to final plat approval. Staff further recommends as a condition of approval that the Preliminary Plat be revised to extend the proposed private access easement located at the southern terminus of NE 3"' Court to the City of Renton P/B/PW Departr BREMERTON TOWNHOMES Preliminary Report to the Hearing Examiner LUA-06-133, PP, CU-A, SA-A, ECF PUBLIC HEARING DATE: December 19, 2006 Page 8 of 20 southern property line. The width of this easement may be reduced down to a minimum of 20 feet in width, however if the width of the easement were reduced the structures on proposed Lots 16 and 17 would not comply with the maximum setback requirements, therefore the location of these structures would have to be revised. The City's subdivision regulations RMC 4-7-150E.5 specifies that alley access is the preferred street pattern. The proposed layout does include 2 private alley easements. Other alley layouts were considered but were deemed infeasible due to the requirement by the Transportation Department that the proposed NE 3'' Court right-of-way line up as closely as possible with the NE 3"' Court on the west side of Bremerton Avenue NE. To mitigate impacts to the local street system, the City's Environmental Review Committee imposed mitigation on the project in the form of the requirement for payment of a Traffic Mitigation Fee. The Traffic Mitigation Fee is based on $75 per net new average daily trip attributed to the proposed subdivision. The proposal would result in the generation of 133.22 new average daily trips, with credit given for the two existing residences, (26 new townhomes x 5.86 trips per home = 152.36 -19.14 credit = 133.22). The fee for the proposed plat is estimated to be $9,991.50 ( 133.22 total trips x $75.00 = $9,991.50) and is payable prior to the recording of the plat. Topography and Vegetation: With the project application, the applicant submitted a Geotechnical Report prepared by Earth Solutions NW, LLC, dated July 19, 2006. According to the report the site topography is relatively level with the exception of the depression area located along the northern portion of the project site. Vegetation on the project site consists primarily of mature landscaping. Temporary Erosion and Sediment Control Plan (TESCP) and the use of Best Management Practices would serve to mitigate potential erosion and off-site sedimentation impacts. The project application includes a Construction Mitigation Plan, which is subject to final approval prior to the issuance of construction permits for the project. In addition, the project will be subject to the DOE manual regarding erosion control, as conditioned by the ERG. A total of 44 significant trees are located on the project site. The proposed clearing limits encompass all of the proposed lots and the proposed roadways. Additional areas outside of the proposed lots and roadways would be cleared for the installation of utility lines (storm drainage and sewer). RMC 4-4-070 indicates that existing trees and other vegetation shall be used to augment new plantings for landscaping where practical, and RMC 4-7-130 requires that a reasonable effort should be made to preserve existing trees. A Determination was made by the Director of Development Services that the retention or replacement of 25% of the existing trees would achieve these requirements. To comply with this Determination, the applicant would be required to retain or replace a total of 11 trees (replacement trees are required to be a minimum of 2-inch caliper trees). The applicant submitted a tree clearing plan, which proposes to retain 5 trees, therefore the applicant shall be required to install 6 2-inch caliper replacement trees throughout the development. Staff recommends as a condition of approval that the applicant submit a Tree Retention and Replacement Plan with the Utility Construction Permit Application to the Development Services Division project manager. The plan shall detail the tree protection measures to be implemented to ensure survival of the retained trees and shall include a planting plan showing the location of the proposed replacement trees. Relationship to Existing Uses: Commercial development is located to the north of the project site and residential development is located to the east, west, and south of the site. The proposed development would be compatible with the surrounding development. (4) Availability and Impact on Public Services (Timeliness) Hexrpt 06-133.doc Police and Fire: Police and Fire Prevention staff indicate that sufficient resources exist to furnish services to the proposed development, subject to the applicant's provision of Code required improvements and fees. Therefore, the City's Environmental Review Committee is requiring the applicant to pay a Fire Mitigation Fee based on $388.00 per new multi-family unit. The fee is City of Renton P!BIPW Depart, Preliminary Report to the Hearing Examiner BREMERTON TOWNHOMES LUA-06-133, PP, CU-A, SA-A, ECF PUBLIC HEARING DATE: December 19, 2006 Page 9 of 20 Hexrpt 06-133.doc estimated at $9,312.00 (24 new units x $388.00 = $9,312.00) and is payable prior to the recording of the plat. Recreation: The proposal does not provide on-site recreation areas for future residents of the proposed plat. However, pedestrian trail easements would connect to the properties to the north, east, and south. There are no existing recreational facilities in the immediate vicinity of the subject property. It is anticipated that the proposed development would generate future demand on existing City Parks and recreational facilities and programs. Therefore, the City's Environmental Review Committee is requiring the applicant to pay a Parks Mitigation Fee based on $530.76 per new unit. The fee is estimated at $12,738.24 (24 new lots x $530.76 = $12,738.24) and is also payable prior to the recording of the plat. Schools: The site is located within the boundaries of the Renton School District No. 403. According to the Draft Environmental Impact Statement for the City of Renton Land Use Element (January 16, 1992), the City of Renton has a student generation factor of 0.44 students per single-family residential dwelling. Based on the student generation factor, the proposed plat would potentially result in 11 additional students (0.44 x 24 = 11 ). The schools would include: Maplewood Elementary School, McKnight Middle School, and Hazen High School. The school district has indicated that they would be able to handle to additional students coming from the proposed development. Storm Drainage/Surface Water: A Preliminary Technical Information Report prepared by Jaeger Engineering, dated September 29, 2006 was submitted with the application materials. According to the report the existing drainage from the north half of the site sheet flows into the depression. The existing drainage from the south half of the site sheet flows to the southwest corner of the site. The proposed method of drainage control as indicated by the storm drainage report would be a detention vault and wet vault located near the southeast corner of the project site underneath the proposed private street. The City's Environmental Review Committee imposed a mitigation measure on the project requiring that the storm drainage system comply with a higher standard for flow control. The project is required to comply with the 2005 King County Surface Water Design Manual. A Surface Water System Development Charge, based on the current rate of $759.00 per new single-family lot, would be required prior to the issuance of construction permits for the plat. Water and Sanitary Sewer Utilities: The project site is located within the 565 Water Pressure Zone. The static pressure at the street level is approximately 70 psi. There is an existing 8-inch water main located in Bremerton Avenue NE (see City of Renton drawing W-3260 for detailed engineering plans). Per the City of Renton Fire Marshall, the preliminary fire flow is 2,500 gpm for attached units 13- 15 and 16-18 and 1,750 gpm for the remainder of the units. All of the buildings are required to be sprinklered. This project is required to install an 8-inch water main connecting to the existing main in Bremerton Avenue NE and looped through the site and connecting back to Bremerton Avenue NE. In addition, the main shall be extended to the east and connect to the existing water main (W3024). The main shall also be extended to the south in the private street to the south property line in a 15-foot easement to the City of Renton. The City of Renton requirements dictate that the lateral spacing of fire hydrants shall be predicated on hydrants being located at street intersections. The utility plan needs to be modified to show fire hydrants at both north and south public right-of-way streets and also a fire hydrant near lot 6. Each unit requires a separate water service line and meter, which will serve domestic and fire. The size is determined by a certified fire sprinkler designer, but shall be a minimum of 1-inch. Any new construction requires a fire hydrant capable of delivering a minimum of 1,000 gpm with one hydrant located within 150 feet of the structure and two additional hydrants located within 300 feet of the structure. This distance shall be measured along the travel route. City of Renton PIB/PW Depart1 BREMERTON TOWNHOMES Preliminary Report to the Hearing Examiner LUA-06-133, PP, CU-A, SA-A, ECF PUBLIC HEARING DATE: December 19, 2006 Page 10 of 20 System Development Charges are $1,956 per dwelling unit. The Development Charges are collected as part of the construction permit. Please note that any parcel that currently has water service is eligible for a prorated System Development Charge. The project will be reviewed to determine how much redevelopment credit applies. There is an existing 8-inch sanitary sewer main in Bremerton Avenue NE (see City of Renton drawing S-3260 for detailed engineering plans). There is an existing 8-inch sanitary sewer main on the north and east side of this site. A sanitary sewer main extension is required to be installed by this project. The applicant shall install individual side sewers to serve the project. The site is located in the East Renton Special Assessment District (SAD 0002). These fees are $316.80 per unit and paid prior to the issuance of a construction permit. The System Development Charges are $1,017 per dwelling unit. The Development Charges are collected as a part of the construction permit. Please note that any parcel that currently has sewer service is eligible for a prorated System Development Charge. The project will be reviewed to determine how much redevelopment credit applies. 6. CONSISTENCY WITH CONDITIONAL USE CRITERIA: A Conditional Use Permit is required in order to permit the construction of a stand alone residential project within the CA zone. Section 4-9-030.G lists 11 criteria that the Hearing Examiner is asked to consider, along with all other relevant information, in making a decision on a Conditional Use application. These include the following: (1) CONSISTENCY WITH THE COMPREHENSIVE PLAN, ZONING CODE & OTHER ORDINANCES: The proposed use shall be compatible with the general purpose, goals, objectives and standard of the Comprehensive Plan, the Zoning Ordinance and any other plan, program, map or ordinance of the City of Renton. (a) Comprehensive Plan Land Use Element See previous discussion above under Preliminary Plat Criteria. (b) Zoning Code The proposed townhome project is located within the Commercial Arterial (CA) zoning designation. The purpose of the Center Arterial Zone (CA) is to evolve from "strip commercial" linear business districts to business areas characterized by enhanced site planning, incorporating efficient parking lot design, coordinated access, amenities and boulevard treatment. The proposed attached townhome development would be permitted in the CA zone subject to approval of a Conditional Use Permit. (c) Development Standards See previous discussion above under Preliminary Plat Criteria and further discussion below under Site Plan Review Criteria. (2) COMMUNITY NEED: Hexrpt 06-133.doc There shall be a community need for the proposed use at the proposed location. In the determination of community need, the Hearing Examiner shall consider the following factors, among all other relevant information: (a) The proposed location shall not result in either the detrimental over concentration of a particular use within the City or within the immediate area of the proposed use. The proposed project would result in the construction of for-sale residential townhomes. Nearby residential project have continued to be successful ventures, therefore the proposal would not result in an over concentration of residential units. City of Renton P/B/PW Departn BREMERTON TOWNHOMES Preliminary Report to the Hearing Examiner LUA-06-133, PP, CU-A, SA-A, ECF PUBLIC HEARING DATE: December 19, 2006 Page 11 of 20 (b) That the proposed location is suited for the proposed use. The subject site is abutting surrounding residential uses on the east, west, and south property lines and would serve as a transition to the commercial property to the north. The proposed attached townhomes would be more compatible with the surrounding residential uses than a commercial use would, as the applicant has indicated that the only viable commercial use of the subject property would be for an auto repair shop. (3) EFFECT ON ADJACENT PROPERTIES: The proposed use at the proposed location shall not result in substantial or undue adverse effects on adjacent property. The following site requirements shall be required: (a} Lot Coverage: Lot coverage shall conform to the requirements of zone in which the proposed use is to be located. See further discussion below under the Site Plan Review criteria. (b) Yards: Yards shall conform to the requirements of the zone in which the proposed use is to be located. Additions to the structure shall not be allowed in any required yard. See previous discussion under Preliminary Plat criteria and further discussion below under Site Plan Review criteria. (c} Height: Building and structure heights shall conform to the requirements of the zone in which the proposed use is to be located. Spires, bell towers, public utility antennas or similar structure may exceed the height requirement upon approval of a variance. Building heights should be related to surrounding used in order to allow optimal sunlight and ventilation, and minimal obstruction of views from adjacent structures. The proposed buildings would comply with the height requirements of the CA zone; see further discussion below under Site Plan Review criteria. (4) COMPATIBILITY: The subject property is located within a predominantly residential area with commercial uses located on the abutting northern properties. The proposed attached residential townhomes would serve as a transition from the higher intensity uses of the commercial area to the lower intensity single family residential uses to the south and would be compatible with the surrounding uses. (5) PARKING: Parking under the building structure should be encouraged. Lot coverage may be increased to as much as seventy-five percent (75%) of the lot coverage requirement of the zone, in which the proposed use is located, if all parking is provided underground or within the structure. All parking is proposed within attached private garages located to the side or rear of the proposed structures. See further discussion below under Site Plan Review criteria. (6) TRAFFIC: Traffic and circulation patterns of vehicles and pedestrians relating to the proposed use and surrounding area shall be reviewed for potential effects on, and to ensure safe movement in the surrounding area. Staff has reviewed the circulation patterns of potential vehicles and pedestrians. See further discussion below under Site Plan Review criteria regarding pedestrian and vehicular circulation. (7) NOISE, GLARE: Hexrpt 06-133.doc Potential noise, light and glare impacts shall be evaluated based on the location of the proposed use on the lot and the location of on-site parking areas, outdoor recreational areas and refuse storage areas. City of Renton P/8/PW Departr BREMERTON TOWNHOMES Preliminary Report to the Hearing Examiner LUA-06-133, PP, CU-A, SA-A, ECF PUBLIC HEARING DATE: December 19, 2006 Page 12 of 20 It is anticipated that the most significant noise impacts would occur during the construction phase of the project. The applicant has submitted a Construction Mitigation Plan that provides measures to reduce construction impacts such as noise, control of dust, traffic controls, etc. In addition, the project will be required to comply with the City's noise ordinance regarding construction hours. There would be noise impacts of increased traffic and activity that are normally associated with an attached townhome development. (8) LANDSCAPING: Landscaping shall be provided in all areas not occupied by building or paving. The Hearing Examiner may require additional landscaping to buffer adjacent properties from potentially adverse effects of the proposed use. See previous discussion above under Preliminary Plat criteria and further discussion below under Site Plan Review criteria. (9) ACCESSORY USES: Accessory uses to conditional uses such as day schools, auditoriums used for social and sport activities, health centers, convents, preschool facilities, convalescent homes and others of a similar nature shall be considered to be separate uses and shall be subject to the provisions of the use district in which they are located. There are no accessory uses proposed. (10) CONVERSION: No existing building or structure shall be converted to a conditional use unless such building or structure complies, or is brought into compliance, with the provisions of this Chapter. No building conversion is proposed. (11) PUBLIC IMPROVEMENTS: The proposed use and location shall be adequately served by and not impose an undue burden on any public improvements, facilities, utilities, and services. Approval of a conditional use permit may be conditional upon the provision and/or guarantee by the applicant of necessary public improvements, facilities, utilities, and/or services. The proposed project will be required to install utilities and construct road improvements as mandated by the City's regulations. See previous discussion above under Preliminary Plat criteria. Section 4-9-030.K lists 6 additional Special Criteria that the Hearing Examiner is asked to consider regarding stand alone residential uses in the NE 4th Corridor Business District, along with all other relevant information, in making a decision on a Conditional Use application. These include the following: (1) Stand alone residential use may not be located within 150 feet of an adjacent or abutting arterial street. This includes Sunset Boulevard, Duvall Avenue, Anacortes Avenue, or Union Avenue in the Sunset Business District; NE 4'h Street, Union Avenue, or Duvall Avenue in the NE 4th Street Business District; and Puget Drive or South Benson Road in the Puget Drive Business District, as shown on the Business District Maps in RMC 4-3-040. The subject site is not located within 150 feet of NE 4th Street, which is the nearest arterial. (2) A mix of commercial, service, and residential uses existing within a 150-foot radius of the proposed residential use. Commercial and service uses are located on the abutting properties to the north, and residential uses are located to the east, west, and south of the project site. (3) Commercial use of the property is not feasible for reasons including, but not limited to: lack of commercial frontage, lack of access, critical areas and/or critical area buffers, or property configuration. Hexrpt 06-133.doc City of Renton PIBIPW Departt BREMERTON TOWNHOMES Preliminary Report to the Hearing Examiner LUA-06-133, PP, CU-A, SA-A, ECF PUBLIC HEARING DATE: December 19, 2006 Page 13 of 20 The applicant contends that due to the lack of frontage along NE 4th Street that commercial use of the property is not feasible except for possibly an automotive repair shop, which does not required commercial frontage. Stall has reviewed the proposal and concurs with the applicant that commercial use of the property is largely unfeasible due to the lack of commercial frontage. In addition, due to the surrounding residential uses to the east, west, and south of the project site it is more desirable to have a residential use on the subject property as opposed to an automotive repair shop, which would not be as compatible with the surrounding residential uses. (4) Residential use will augment the primary purposed of the commercial arterial zone by adding a pedestrian oriented land use that provides a physical connection between residential and commercial uses. The proposed development would provide pedestrian connections to the surrounding residential and commercial uses along the north, south, east, and west sides of the property. (5) The use provides a transition between commercial and lower density R-10 and R-8 zoned areas and provides a visual, pedestrian, and vehicular connection from the residential zoned areas to the Commercial Arterial zoned areas. The proposed development would serve as a transition from the northern commercial properties to the single family residential (R-8) properties located to the south of the site. In addition, pedestrian connections are proposed, which would provide a connection for the residential properties to the commercial properties. (6) Development standards from RMC 4-3-040F are met unless the applicant opts for a planned urban development, subject to RMC 4-9-150. Pedestrian connection standards from this section must be met without modification. The development standards as outlined in RMC 4-3-040F would be met without modification. 7. CONSISTENCY WITH SITE PLAN REVIEW CRITERIA: In reviewing the proposal with respect to the Site Plan Approval Criteria set forth in Section 4-9-200.E of the Site Plan Ordinance, the following issues have been identified by City Departmental Reviewers: 1. Conformance with the Comprehensive Plan, it's Elements and Policies; See previous discussion above under Preliminary Plat criteria. 2. Conformance with existing land use regulations; Hexrpt 06-133.doc The subject site is designated Commercial Arterial (CA) on the City's Zoning Map and is located within the NE 4th Street Corridor Business District. The proposed attached townhome development is a permitted use within the CA zone subject to the approval of a Conditional Use Permit. The compliance of the proposal with the development standards of the CA zone and NE 4th Street Corridor Business District regulations is addressed below: Lot Coverage -The CA zone allows building coverage at a maximum of 75% of the lot area as all of the parking would be contained within the individual buildings. The proposed building lot coverages range from a minimum of 17 percent to a maximum of 43 percent, which is well below the maximum 75 percent building lot coverage permitted. Setbacks -In the CA zone, the minimum front yard setback is 10 feet and may be reduced down to zero feet through the site plan review process provided no blank walls are located within the reduced setback. In the NE 4th Corridor Business District, the maximum front yard setback permitted is 15 feet. A 10-foot side yard along a street setback is required, which may be reduced down to zero feet through the site plan review process provided no blank walls are located within the reduced setback. A 15-foot side or rear yard setback is required where the property abuts to or is adjacent to a residential zone. City of Renton P!BIPW Depart, BREMERTON TOWNHOMES Preliminary Report to the Hearing Examiner LUA-06-133, PP, CU-A, SA-A, ECF PUBLIC HEARING DATE: December 19, 2006 Page 14 of 20 Hexrpt 06-133.doc The City's Urban Design Regulations define a blank wall as a ground floor wall or portion of a ground floor wall over 6 feet in height, has a horizontal length greater than 15 feet, and does not include a window, door, building modulation or other architectural detailing. The proposed structures units on Lots 1-8, 11, 16-18, 25, and 26 would all have a front yard setback between 10 and 15 feet, which complies with the minimum and maximum front yard setback requirements. The proposed structures on Lots 12-15, 19, 21, and 22 would all have front yard setbacks that are less than 10 feet. The minimum front yard setback proposed is 4 feet. Each of the front yard facades for the proposed structures on Lots 12-15 would not have blank walls located within the front yard setback as these structures provide a window, door, or building modulation every 15 feet along the ground floor. Therefore the structures proposed on Lots 12-15 would qualify for the proposed reduced front yard setbacks. The structures on Lots 19, 21, and 22 have front facades that would qualify as blank walls and would not be permitted the proposed reduced front yard setbacks. Staff recommends as a condition of approval that either the building elevations be revised showing additional architectural detailing on the front fa9ade of the buildings proposed to be located on Lots 19, 21, and 22 such that the front facades would no longer qualify as blank walls, or the site plan shall be revised providing a minimum front yard setback of 1 O feet for the structures proposed on Lots 19, 21, and 22. The revised materials shall be submitted to the Development Services project manager at the time of building permit application. The proposed structures on Lots 9, 10, 20, 23, and 24 would be located outside of the maximum 15-foot front yard setback area. The NE 4th Corridor Business District requirements do not provide for any modification of the maximum front yard setback, therefore, the proposed front yard areas for the structures on Lots 9, 10, 20, 23, and 24 shall be revised to comply with the maximum front yard setback of 15 feet. Staff recommends as a condition of approval that the site plan be revised to provided the 15-foot maximum front yard setback for the structures proposed on Lots 9, 10, 20, 23, and 24. A revised site plan shall be submitted to the Development Services Division project manager at the time of building permit application. Proposed Lots 1, 3-11, 13, 15, 19, 21-24, and 26 all have side yards along streets or access easements and would therefore be required to provide side yard along street setbacks for the proposed structures. The structures on proposed Lots 1, 6, 7, 15, 19, and 26 would comply with the required 10-foot side yard along a street setback requirements. The structures on proposed Lots 3-5, 8-10, 13, and 21-24 would provide less than the required side yard along a street setback. The minimum side yard along a street setback proposed is 2 feet. The proposed structures on Lots 3-5, 8-10, and 24 would not have blank walls located within the side yard along a street setback as these structures provide a window, door, or building modulation every 15 feet along the ground floor. Therefore the structures proposed on Lots 3-5, 8-10, and 24 would qualify for the proposed reduced side yard along a street setbacks. The structures on proposed Lots 13, and 21-23 would have blank walls within the reduced side yard along a street setback, which is not permitted. Staff recommends as a condition of approval that either the building elevations be revised showing additional architectural detailing on the side yard along a street fa9ade of the buildings proposed to be located on Lots 13, and 21-23 such that the side yard along a street facades would no longer qualify as blank walls, or the site plan shall be revised providing a minimum side yard along a street setback of 10 feet for the structures proposed on Lots 13, and 21-23. The revised materials shall be submitted to the Development Services project manager at the time of building permit application. A 15-foot side yard setback is required for the structures proposed on Lots 15 and 16 as these lots abut an R-8 zone. The proposed structures exceed the minimum 15-foot side yard. Landscaping -The City's landscaping regulations require the installation of landscaping. The minimum amount of on-site landscaping required along street frontages is 10 feet, except where the front or side yard along a street setbacks have been reduced through the site plan review process. Where the property abuts the R-8 zone a 15-foot wide landscaped visual barrier consistent with the definition in RMC 4-11-120 is required. A 10-foot sight-obscuring landscaped strip may be allowed through the site plan review process. The applicant submitted a Conceptual landscape plan with the project application. The submitted landscape plan provides a 10-foot City of Renton PIBIPW Depart .. BREMERTON TOWNHOMES Preliminary Report to the Hearing Examiner L UA-06-133, PP, CU-A, SA-A, ECF PUBLIC HEARING DATE: December 19, 2006 Page 15 of 20 Hexrpt 06·133.doc landscape strip along all street frontages, except where the front and side yard along a street setbacks are proposed to be reduced. Along the southern property line, where the site abuts an R-8 zone, a 15-foot wide landscape visual barrier is proposed along the side yard of Lot 16, and a 10-foot wide sight-obscuring landscape strip is proposed along the side yard of Lot 15 due to the proposal for a 5-foot pedestrian access easement providing access to the property to the east. After looking at the approved site plan for the proposed project to the east, it appears that the proposed pedestrian access easement at this location would terminate in what will eventually be someone's back yard. Staff recommends that the proposed pedestrian access easement located along the southern property line of Lot 15 be removed and replaced with landscaping to provide a 15-foot landscaped visual barrier along the southern property line of Lot 15. Staff recommends as a condition of approval that a revised landscape plan be submitted with the building permit application for Lot 15 providing a 15-foot landscape visual barrier for review and approval by the Development Services Division project manager. Height -The CA zone allows a maximum building height of 35 feet for residential structures. The proposed structures would have a height of 29 feet, which is below the maximum height permitted. Pedestrian Connections -All development in the CA zone within the NE 41 " Street Corridor Business District is required to provide a minimum of one pedestrian connection from the entry of each building to the street and sidewalks, and a minimum of one pedestrian connection is required from each side of a property to commercial and/or residential uses. The submitted preliminary plat map identifies a minimum of one pedestrian connection to each side of the property. The sidewalks required along the new NE 3"' Court would connect pedestrians out towards Bremerton Avenue NE, a 5-foot pedestrian access easement on the northeast portion of the site would connect pedestrians to the north and east property lines, and a pedestrian connection located on the southeast portion of the site would connect pedestrians to the Laurelhurst Division 3 Preliminary Plat to the south. An additional pedestrian connection is identified on the southeast portion of the site connecting to the property to the east; however after looking at the approved site plan for this property it appears that a pedestrian connection at this location would terminate in someone's backyard. Therefore, staff recommends as a condition of approval that the proposed 5-foot pedestrian access easement located along the southern property line connecting to the property to the east be removed. A revised plat map showing the removal of this easement shall be submitted prior to the approval of the final plat to the Development Services Division project manager for review and approval. All pedestrian connections shall comply with the design standards at outlined under RMC 4-3- 040F .1 .e. ii. Parking -The parking regulations require a specific number of off-street parking stalls based on the proposed use. A maximum of 1.75 parking spaces per dwelling units may be permitted. When the unit of measurement determining the number of parking spaces required results in the requirements of a fractional space, any fraction up to 0.5 spaces shall be disregarded and any fraction 0.5 spaces and above shall count as one space. Therefore, each dwelling unit shall be required to provide 2 parking spaces. Each proposed townhome has proposed 2 spaces each within a private garage. All code required spaces must comply with the dimensional requirements of the parking regulations. For standard stalls, each stall must be a minimum of 20 feet long and a minimum of 9 feet wide. The applicant's site plan proposes to provide compact parking stalls on Lots 1-6. As the parking provided throughout the development would not be shared parking, the parking requirements would be calculated for each proposed town home unit. The minimum amount of compact stalls permitted per unit would be 30 percent. As, the units would only have 2 parking stalls within the garages the provision of 30 percent of the stalls as compact stalls would result in 1 stall being permitted to comply with the compact stall dimensions. Staff recommends as a condition of approval that the site plan be revised to provide a maximum of 1 compact parking stall within the private garages proposed for Lots 1-6. The revised site plan shall be submitted to the Development Services Division project manager for review and approval with the submittal for the building permit application. City of Renton PIBIPW Depart, BREMERTON TOWNHOMES Preliminary Report to the Hearing Examiner LUA-06-133, PP, CU-A, SA-A, ECF PUBLIC HEARING DATE: December 19, 2006 Page 16 of 20 Refuse and Recyclable Deposit Areas The location and pick up of the service elements shall be approved by Waste Management. Currently it appears that the service elements for each town home would be located within each individual unit. The City's refuse and recyclable deposit area regulations do not apply to attached duplex structures, but would be applicable to the triplex structures. Therefore, staff recommends as a condition of approval that a modification to the Refuse and Recyclable requirements be submitted with the building permit applications for the triplex structures exempting them from the common collection area requirement of this section if Waste Management determines that common collection areas for the refuse and recyclable deposit areas would not be required. 3. Mitigation of impacts to surrounding properties and uses; The proposed residential project is not anticipated to result in any adverse impacts to surrounding properties and uses. The properties to the east, west, and south are all have residential uses on them and the properties to the north have commercial uses on them. The proposal for the construction of townhomes on the subject site would provide a transition from the commercial uses to the north to the single family residential uses to the south. In addition, pedestrian connections are proposed, which would connect pedestrian in developments to the south of this site to the commercial area to the north. There are potential short-term impacts to adjacent properties (e.g., noise), which would result from the construction of the project. These impacts will be mitigated by the applicant's construction mitigation plan, which limits work and haul hours to those permitted by City Code. Long term impacts included increased traffic associated with a residential townhome development. These impacts were anticipated through the Comprehensive Planning and Zoning process. 4. Mitigation of impacts of the proposed site plan to the site; The proposed residential structures are oriented to provide front yards facing the new public street (NE 3'" Court) or a private access easement. Each structure would have an individual backyard that would be located away from any street frontages and the landscape plan proposes to landscape along the perimeter property lines with shrubs, which will provide some privacy for the residents. 5. Conservation of area-wide property values; The proposal would allow existing surrounding uses to continue operating in their present locations and would not result in a reduction of surrounding property values. 6. Safety and efficiency of Vehicle and Pedestrian Circulation; The proposed project would provide access to Bremerton Avenue NE via the proposed public street NE 3•d Court. In addition, pedestrian sidewalks along the new public right-of-way as well as private pedestrian access easements are proposed to provide safe and efficient pedestrian access throughout the site and to other abutting sites. See previous discussions regarding access under the Preliminary Plat Criteria and pedestrian connections. 7. Provision of adequate light and air; The proposed buildings are designed appropriately to allow adequate light and air circulation to the buildings and the site. The design of the buildings will not result in excessive shading of the property. In addition, there is ample area surrounding the building to provide for normal airflow. 8. Mitigation of noise, odors and other harmful or unhealthy conditions; Hexrpt 06-133.doc The proposal is not expected to create any harmful or unhealthy conditions. Noise, dust, and odors, which may result from the temporary construction on the site, will be mitigated by the applicant's construction mitigation plan and code requirements for the use of Best Management Practices. City of Renton P!B!PW Depart. BREMERTON TOWNHOMES Preliminary Report to the Hearing Examiner LUA-06-133, PP, CU-A, SA-A, ECF PUBLIC HEARING DA TE: December 19, 2006 Page 17 of 20 9. Availability of public services and facilities to accommodate the proposed use; See previous discussion above under Preliminary Plat Criteria. 10. Prevention of neighborhood deterioration and blight. No deterioration or blight is expected to occur as a result of the proposal. The site is proposed to be developed with attached townhome units that would be compatible with existing commercial and residential uses in the surrounding neighborhood. 11. Review of Compliance to District B Design Guidelines. Hexrpt 06-133.doc The Bremerton Townhomes project site is subject to the District B Urban Center Design Regulations. The Hearing Examiner shall have the authority of approve, approve with conditions, or deny proposals based on the provisions of the design regulations. In rendering a decision, the Hearing Examiner will consider proposals on the bases of individual merit, will consider the overall intent of the minimum standards and guidelines, and encourage creative design alternatives in order to achieve the purposes of the design regulations. Site Design and Building Location Site Design and Street Pattern: Maintain existing grid street pattern The proposed project would not adversely impact the existing grid street pattern in the surrounding neighborhood. The City does not anticipate the need for the proposed street system to connect to adjacent properties due to the current adequate provision of access to the neighborhood. Building Location and Orientation: Orient Buildings to the street with clear connections to the sidewalk. All of the buildings would be oriented towards a street or private access easement and would provide clear connections to the sidewalks from the front doors and/or driveways. Building Entries A primary entrance of each building shall be located on the far;ade facing a street. Such entrances shall be prominent, visible from the street, connected by a walkway to the public sidewalk, and include human scale elements. Secondary access (not fronting on a street) should have weather protection at least four and one-half feet wide over the entrance or other similar indicator of access. Each of the proposed buildings is oriented to provide a front yard facing towards the new public street (NE 3"' Court) or a private access easement. The building entrances as showing on the building elevations would be prominent and visible from the street. A direct connection would be provided to the public street. Each of the secondary pedestrian entry to the proposed buildings shall have weather protection at least 4 Yz feet wide over the entrance. The requirement applies to the side and/or rear entries on Buildings A, B-F, G-H, I, & L. Staff recommends as a condition of approval that revised building elevations showing 4 Y, feet of weather protection over each of the side and rear secondary pedestrian entries be submitted with the building permit applications for review and approval by the Development Services Division project manager. Transition to Surrounding Development Careful siting and design treatment is necessary to achieve a compatible transition where new buildings differ from surrounding development in terms of building height, bulk, and scale. At least one of the following design elements shall be considered to promote a transition to surrounding uses: Setbacks at the side or rear of a building may be increased in order to reduce the bulk and scale of larger buildings and so that sunlight reaches adjacent yards; or Building City of Renton P/B!PW Departr BREMERTON TOWNHOMES Preliminary Report to the Hearing Examiner LUA-06-133, PP, CU-A, SA-A, ECF PUBLIC HEARING DATE: December 19, 2006 Page 18of 20 Hexrpt 06-133.doc articulation provided to divide a larger architectural element into smaller pieces; or Roof lines, roof pitches, and roof shapes designed to reduce apparent bulk and transition with existing development. Where the proposed townhomes abut a single family (R-8) zone, the side yard setbacks have been increased to 15 feet to reduce the impact of the multi-family development on a single family use. Service Element Location and Design Service elements shall be located and designed to minimize impacts on the pedestrian environment, concentrated, and located where easily accessible to service vehicles. In addition, to the enclosure requirements addressed in the development standards the design regulations required that service areas be enclosed on all sides including the roof to prevent the attraction of birds to the service areas. See previous discussion above under Refuse and Recyclable Deposit Areas. If it is determined that a common collection area would be provided for the refuse and recyclable deposit areas, the design and screening of the collection area shall be consistent with this section. Parking and Vehicular Access Location of Parking No surface parking shall be located between a building and the front property line or the building and side property line on the street side of a corner lot. No surface parking is proposed. Vehicular Access Parking lots and garages shall be accessed from alleys when available. Access to the individual parking garages would be provided off of an alley when available. Landscaping/Recreation Areas/Common Open Space Landscaping All pervious areas are required to be landscaped and the landscaping shall be consistent with the design intent of the development and shall reinforce the concept of the development. Street trees are required and shall be between the curb and buildings. A landscape plan was submitted with the application materials. The proposed landscaping would include street trees located between the buildings and the sidewalk. The proposed landscaping would enhance the proposed development and would provide a vegetative theme throughout. Recreation Areas and Common Open Space Attached housing developments shall provide a minimum area of private usable open space equal to 150 square feet per unit of which 100 square feet are contiguous. Such space may include porches, balconies, yards, and decks. Each proposed unit would have an excess of 150 square feet of open space within the front and/or rear yard areas. Building Architectural Design Building Character and Massing All building facades shall include modulation or articulation at intervals of no more than 20 feet. Building facades should be modulated and/or articulated with architectural elements to reduce the apparent size of new buildings, break up long blank walls, add visual interest, and enhance the character of the neighborhood. Articulation, modulation, and their intervals should create a sense of scale important to residential buildings. A variety of modulations and articulations should be employed to add visual interest and to reduce the bulk and scale of large projects. City of Renton PIBIPW Depart, BREMERTON TOWNHOMES Preliminary Report to the Hearing Examiner LUA-06-133, PP, CU-A, SA-A, ECF PUBLIC HEARING DA TE: December 19, 2006 Page 19 of 20 Staff has reviewed the submitted building elevations and recommends that additional modulation and articulation be added to the building facades. Staff recommends that the street or front elevation of Building A be revised to include additional horizontal or vertical change in plane of the fa<;:ade or some variation in the materials used along the base of the fa,;:ade and that the rear fa,;:ade be revised to include additional horizontal or vertical change in plane. The rear elevation of Buildings B-F shall be revised to include a horizontal or vertical change in plane on the fa,;:ade or some additional variation in the materials used along the base of the fa,;:ade. Staff recommends that the weather protection proposed over the primary entrances to Buildings G-H be revised to mimic the pitch and materials used on the roofs. The rear fa<;:ade of Buildings J & K require additional modulation and articulation. Staff recommends as a condition of approval that revised building elevations be submitted to the Development Services Division project manager for review and approval with the building permit applications. Ground-Level Details Untreated blank walls visible from public streets, sidewalks, or interior pedestrian pathways are prohibited. A wall is considered a blank wall if: It is a ground floor wall or portion of a ground floor wall over 6 feet in height, has a horizontal length greater than 15 feet and does not include a window door, building modulation or other architectural detailing. See previous discussion above under setbacks. Building Roof Lines Buildings containing predominantly residential uses should have pitched roof with a minimum slope of one to four. Such roof should have dormers or intersecting roof forms that break up the massiveness of a continuous, uninterrupted sloping roof. The roof color shall be dark. The proposed roofs all have slopes that exceed the minimum one to four required. In addition, intersecting roof forms are proposed to break up the sloping roof. Building Materials All sides of buildings visible from a street, pathway, parking area, or open space shall be finished on all sides with the same building materials, detailing, and color scheme, or if different, with materials of the same quality. Buildings shall employ material variations such as colors, brick or metal banding, patterns, or textural changes. The proposed building facades include the same materials around the buildings. H. RECOMMENDATION: Staff recommends APPROVAL of the Bremerton Townhomes Preliminary Plat, Conditional Use Permit, and Site Plan, Project File No. LUA-06-133, PP, SA-A, CU-A, ECF subject to the following conditions: 1. The applicant shall comply with all requirements of the Determination of Non-Significance -Mitigated that was issued by the Environmental Review Committee on November 20, 2006. 2. Demolition permits shall be obtained and all inspections completed on the demolition of the existing residences and detached accessory structures prior to final plat approval. 3. "No Parking" signage shall be placed along the private access easement that extends off of the southern terminus of NE 3"' Court and serves the two triplex structures. 4. A homeowner's association shall be created concurrently with the recording of the final plat in order to establish maintenance responsibilities for shared roadway, stormwater and utility improvements. A draft of the document(s) shall be submitted to the City of Renton Development Services Division for review and approval by the City Attorney and Property Services section prior to the recording of the final plat. 5. The preliminary plat map shall be revised to extend the private access easement located off of the southern terminus of NE 3"' Court to the southern property line. A revised preliminary plat map shall Hexrpt 06-133.doc City of Renton PIBIPW Depart, BREMERTON TOWNHOMES Preliminary Report to the Hearing Examiner LUA-06-133, PP, CU-A, SA-A, ECF PUBLIC HEARING DA TE: December 19, 2006 Page 20 of 20 be submitted with the Utility Construction Permit application to the Development Services Division project manager for review and approval. 6. A Tree Retention and Replacement Plan shall be submitted with the Utility Construction Permit Application to the Development Services Division project manager for review and approval. The plan shall detail tree protection measures to be implemented to ensure survival of retained trees and shall include a planting plan showing the species and location of replacement trees. 7. Either the building elevations shall be revised showing additional architectural detailing on the front facades of the buildings proposed to be located on Lots 19, 21, and 22 such that the facades would no longer qualify as blank walls, or the site plan shall be revised to provide a minimum 10-foot front yard setback for the structures proposed on Lots 19, 21, and 22. T_he revised elevations or site plan shall be submitted to the Development Services Division project manager at the time of building permit application for Lots 19, 21, and 22. 8. A revised site plan shall be submitted to the Development Services Division project manager with the building permit application providing a 15-foot maximum front yard setback for the structures proposed on Lots 9, 10, 20, 23, and 24. 9. Either the building elevations shall be revised showing additional architectural detailing on the side yard along a street facades of the buildings proposed to be located on Lots 13, and 21-23 such that the facades would no longer qualify as blank walls, or the site plan shall be revised to provide a minimum 10-foot front yard setback for the structures proposed on Lots 13, and 21-23. The revised elevations or site plan shall be submitted to the Development Services Division project manager at the time of building permit application for Lots 13, and 21-23. 10. A revised landscape plan shall be submitted with the building permit application for Lot 15 to the Development Services Division project manager for review and approval. The revised landscape plan shall replace the proposed 10-foot sight-obscuring landscape strip with a 15-foot wide landscaped visual barrier along the southern property line. 11. A revised preliminary plat map shall be submitted to the Development Services Division project manager for review and approval prior to the approval of the final plat. The revised preliminary plat shall show the removal of the proposed 5-foot pedestrian access easement along the southern property line connecting to the property to the east. 12. The site plan shall be revised to include a maximum of 1 compact parking stall within the private garages of proposed Lots 1-6. The revised site plan shall be submitted to the Development Services Division project manager for review and approval with the building permit applications for Lots 1-6. 13. A modification to the Refuse and Recyclable Deposit Area regulations shall be submitted with the building permit applications for the triplex structures. The modification shall request the exemption of these structures from the common collection area requirements of this section if Waste Management determines that common collection areas would not be required. The modification request shall address the criteria outlined in RMC 4-9-250D. 14. Revised building elevations shall be submitted at the time of building permit application to the Development Services Division project manager for review and approval. The revised building elevations shall show a minimum of 4 Y, feet of weather protection over each side and rear secondary pedestrian entry, additional plane changes or material variation along the base of the front fa9ade of Building A and the rear facades of Buildings B-F. The weather protection proposed over the primary entrances to Buildings G-H shall be revised to mimic the pitch and materials used on the roofs, and the rear fa9ade of Buildings J & K require additional modulation and articulation. EXPIRATION PERIODS: Preliminary Plats (PP): Five (5) years from final approval (signature) date. Site Plan Approval (SA-A): Two (2) years from final approval (signature) date. Conditional Use Permit (CU-A): Two (2) years from final approval (signature) date. Hexrpt 06-133.doc NG COUNTY OPARTMENT of ASSESSMENTS r. t ....J l ~ • ., • I, l;'"'"/:;~c:J.:~1:J:;.J.i:L:.l.~~.;:.J~--;,---. i :··. ··-:::. ' • • • • °'':.;,--·---1 ' .. ·' I:• I, !i! )MARTIN'S ACRE , • .. _ _,.. = 'i' • 4 ' -., • ... " I = I. f 1 ,:;.• i - + !.· ~ , S< ... 1:1200 It"" 100") j,(. . ' ,I ;, i :' 'i "'""'"""' / >J ""' h'---"---"' ----•• ~:..,,L •. o.._ .. _, _____ .... ~~.---·-r-~.-~-,~----:=-.:...: -=· =· • , ;;:;:::a;•• ............. ~i i lil!!ll!llllli i I I :.: ... ~ ...... :i: ......... ~~ i . ; • • 1!!! '!!& I 0 l; I ls1 1 l~;1 :1 '.-:; . • -·I ~,, ~1, ; ' ' ! J~ lb i . i1' l t I • ~ I ! n ~ ~ ~ t ,; • l ~ ~ i " . d ~ • ~!r!H a rs19!: I 1! IIH I I 1---- "' "' z ,, > z g "' f' • I l ! 11 11-... -ONlCAoO<T BROIERTON A\C TOIINHO&l£S ~--JAEGER E.NGINEERING .:& ':.. ":m '.£1.JMNARY PU. T MAP -.. ..,,. :_,, :,_ r I I ~ I t ,~, II.Al« IICIISSO a wrs » .. ,, SDulfli 10IM ~ L:....:-&:..1!.1:..U..Ll.-_;-=.::<-=-::;""':=..-...!.. , • RO ~TDil Al€. ~ ::""'=":.;' :;:"":......----l.LJJ ....... ::U.......J A PORTION of the N.E. 1/4 & N.W. 1/4, SECTION 15, TOWNSHIP 23 N., R4NGE 5 E., W.M. -I I I I L D0CflNIIHL f!INDINC I ,1 {, , r .. i ·JO ','" •·••·• AU. ll'IIE• ,-,:1""' r .-.e , ( \ ~ .... .... ,.,. '·•il'•-• m:.m.":r..i' : 11" MJ.HQ-ll"'lrl:IJl:T.- ··r. • -· . 11 ' ~ 1i., :r;i:.; I ·;7~,.:__-=..,:_ ___ --:_..--... ___ ::--J/ /Jrri .. iii---·· \ 111\l'l~\\l..{I -"'J. l)a""IACII; N'CJ MIi ... ~. '''-" .;:.... I ~:'.·.·---jC::·~r;-·;;,;-·:.·:.·.·-=--~ /~'!'~;.,'1:,~.:.:",::i·•• ----·1nl , isni -,...-' 0 -;,,.;u~L«:~ -_ ~;'!!;r~ ...... w.,!r .---··- ), ~--, !.. ~-~~·~~'L ~ ;'"t·>-,1;··,:n-_,~r ,_., tr,ll;llpT r-.ll,:,-.":"" 1 r: .... J , r-, ,r ro-A~~ l,1 ~ '-' I \ I 1 l 1 , , JI I ~ ' I '1 I I _:...1 I 1' 8 J I I ::t~11' :' i': ~J . • I _,I• --1,-....jl-i, "';;;j~il .. J :, r,.,,....;,+f._.,,Vf!)i !f-...,.~/t m1 ------~G-~~--1 ·~-1.i-. ,,, .. ~ _____ i"Jifi~. -~. NE "' CT. =2 . II ~ -------~:;: ... 1~J f i s·1,·· ,,.~ (' c.,O"' I) 11 jl --!-'\}\ ~11! "ii I , {;,G'° I :,1 I .... ti ~ 11 ..• ,,' ,\Ill'\.~ I 1\0 ..... ,,uc .... ~ .~ .~ • ..,-· . I.AKIClor J~Nr·---·-Tit~ · - I rff • \_-l°•llU"- 1 I'.: =:7..! .,11" ,,,.n s.;;,c:::--.Jt\Ji~ il 11-, / ,·: ,,..~ I'--1J., '• j_ k, I flll= .. ~--... *" ... !.t«IJ::t{::::1J~o I ~~ ~ fll'!'.·.·,·rr--•• ··----~"t..-m,"9-, 'f nJ;, ISl'l<U l - :J f2-:: .-,,,·!\-~ I ~rteor-•nt .... _, rboiOI ¥&U,.f/w[ •"U. ~fN ci:•rt• "': ,ea: u,( _,_ J-1..J 111:l'f .... l, "' 410 ,o, 406 ,., ~ • ii-15 13 Iii 1--l- ,, L., L~ -1/' .61/ \ d~ .. 1r11s111'c en •I l GRAPHIC SCALE H ,._, ·--· ti. -- / ,__ $ t " ... ,. __ l_.,. ___ _ "'"" ''"'' (Cl!.,. ~ ... , ....... ,,._,IP!. - rw. INTUIIOR PLA r ROAO ..,, "111:,l&t DRAINAGE DETENTION: VAULT LEVEL 2 DETtTION ST~DARO suesuRr AC[ CONC. VA.ULT VAULT OIM[NSIONS: 88' 11 42' 11 7.0' O([P TOP UO ELEV: 40&.0 DESIGN 50 YR. WA ltR lE"IELl 4CM.5 BOTTOM WAlrR lEVEL/OUTlET: JSl7.5 VOLUME PROVIDED: 2~872 CF" Vot.Utr.lE REQUIRED: 2~20 Cf WATER QUALITY: 'IIETVAULT W(TVAULT BELOW OET!NllOH STORAGE TOP 'W(TVAUL T EL!V: Jlil7.~ BOTTOM WETPOND ELEV: 29J.5 VOLUME PRO'i10ED: 7392 er VOL.UM[ REQUIRED: 6760 Cf VETVAULT DIMENSIONS: B6' • 21' l< 4.0' DEEP l 412 I 410 DEVELbPM[NT PLAN~ 408 CITY oic RtNTON 408 ,, - 0 z l!di ~Ada wl~, er•! I wi • ~ <( ., I i~ g ~Ii: '!J!ll!i i~:1 11 l ... 1,.,1 ••t ,j!of . ' ·01 -·: ~·\!r.1,r"'~T· ~ "c:.;;;;::::::::.:. 1 ' l P . tc~:.;,~~~"' -··1· --om ,. Surveying --- I" 404 DEC o 6 l!ll; I::_!; 402 RECEIVED =~ 400 = ,.. ,o, · .. r- -1 I I I I I I I I I I I I I I I I !!ii I 402 400 -•-•-1-\--+--t-++-l----l--+~H-+-.;;1-lr---.-0-,---1-1-•-H-B:H-- _ _1_ L--~~~~- 1 +00 2+00 J+OO "' 4+00 ~· • IIIIIIIU ---..L- • ..L_ PROFILE -INJfu~e,~. ~OOP "°''' •. -J' ROAD A PORTION of the N.E. 1/4 & N.W. 1/4, SECTION 15, TOWNSHIP 23 N., RANGE 5 E., W.M. I : I I L o.t-looc1~it1r1~to1Ni; I ,11u J ' , \ I ]L --· L • ,r.r:.1•, ' "·=.,,,,· : """' ~ ~I.le ~::~111;:,::: I tt~· ' -_11 ~r,r.=-· '• '' ---·--------------'' 't<l~)J·--·· -~~f t~/-....... : .. ·._:·:.~--;;,'~:;~;;fl~[=-~~~~ ' '.,H~-'" F:..<:" :, r j (t, . ·r··-~-,~---· 1Ri 111 . ., I:; lt1l,._ ' , - J .1:rn:, iffl.wH~~fl-h '"·:""~~ :!, I I '. ·.r t1.i'.>,PI f ll,h, • .. ··-~r.---,, ~1 , i .r .. -·· • : i , -------~-~:\ !~[,!: I fit jj"'::,.f::1-:J ·· • ~ • =----=N,::>,--'-::~--~ }l: j"i_ll\ 1; If f I e,O k1:'!:21H~ ti: I 11. -- -...."<.;_..~ ~ ~ I I c,S 1, I ·1 1 ... ._ ,t,.'v i I r I '1 , '-""~ ~ .... ,:i• 'f1 .. fl I ·-·1:-.. ! ,[., /. ' ' I & ••• I _...;; r"il~~,.---J..1-L. . l_ / ~ ~ " i ! ""·~-""-l1U1~' r il : l"o!'-~rr---., .. _ -----~·-"----,..,,,ff.,,;;,,v,, .. ~--~ t,, ... ~.;·-~ r.:::-•· : t, I I I :::.c o·,r.\{ t·· ~.,,; ... __ .... ~,,. q,- . ii W,,-!!e':!:'.r-• ,• , 1 c!( I :;I; 11~1 -"\! . I '°"°"'---r-1£'1'•"' I . ~ Centn: --·--· -·~·l ---Pointe 111!"1 •-t• Surveying GRAPHIC SCALI: ·r • .J .. .. i',..• ·H 1•-1 ,-.... R 1111 ,,~~11\_I) ,,,.,., ~,111' .,.,--- - "''~ ~,1t.O LEGEND (XISTING lREES ({ TR((S TO BE REMO'tt:D ~ .. CLEARING Ut,UTS PROPOSED CONlOUR --~---- EXISTING CONTOUR • ,., PRCUII. OAADINO Q,Wf11'11E5.: "-l: 4000 (:'I' OJT: 500 CY DEVE/oPMENr PLANN,:, 18 l,// y (.Jf· RENro.,i D£c a 6 2006 f··;, .. .. . .. ~ .~, ,,, .. ,' ..... , ' ..... ~ ~""-'! I<' A'~~"- 0 z i1d1 ~!d; wit, a:::t-w' 0 ~ , t:: ~ ~-i (~ i:! l:t~ ~;f!l; ... .... ~ ill ,I ~· la 111 §ij l'J 11 :1, l" •• .lllldL -""·· --.. --..ML---.. _ _,_ . -'- A PORTION OF THE N.E. 1/4 OF THE N.W. 1/4, SECTION 15. TOWNSHIP 23 N. RANGE 5 E .. W.M NOTE: TREET TAEE LOCATIONS AND QUANTITIES ARE PPROXIMATE ANO SHALL BE ADJUSTED PER FINAL DRIVEWAY AND UTILITY LOCATIONS. ---------------··1 : ~ ~-L .• T.-...LMC<I<:.-.; ......... ....,., ....... "'-"'" n:""-'- ______________ _) ~~ 3rd CT -·--- --------------~ !,i ~ z 0 > ~ '" ~ '"' ~ rn ~-- J > I I I I I 1 I " }i p -I a --, I > --, : L _,.,T Doi.OCWtT• 1T""""- "!'J; n SCALE: 1·. 20· 1' M.T ... ..... ,,TM ........... l~ ......... TT"'<="1..M,1,.,a -·l·1-~-··-· I ~ ..EP-'--'"£•<• ~ !!J i~d I u ii '' 1 !! ! 'l 1. I i • ~ 1! (i _j z w :;; a. g w tu 0 w a: w ~ 0) U) I w ~ ) . 3 z. ~~ 8~ ~i f-~ a: ~ w I!' ~ w ~ ! ' 6 L-1 "'2 ... ,., )> (,-J 0 ;---fT, '"! (I ,- ~ .- ' -- ~ CC, [D I ~ -7" r-1 "' :':,~ -. C; ---, [D I '1 l/) 0 "1 0 -· 'l . '! ! .--c:; I 0 ~ i !I I l/l I ---I ! CD I C'l C'l ' "" I ,i, ,,, ~[ :1; t--'" o· ~ 10-0· ELEVATIONS BLDG A & 8-F -l ! ~- 330 .MERTON 1501h AV[tW[ R@nlon. WA G -;l '"· rt . ".-- --0 '"'·o· ' )> Ul 0 C'l _ ,_ ~I; \~ JJ S-(" -5- DRISCOLL ARCHITECTS . ~~ .......... ,__ '·--- ~·····""""" <•- ~:, clc uh:,,, BUILDING G-H I ·~·· ~ I I L I, 1:, --\ I 11111111,I IUlii I LIi II II I IWl.11 Ill -''-"".l' .,,. -· '7 ,[, '"" --;,(, ::-o· , .,, ',C' ii!> ' ,~ .,,,=, -·~,,.'I ,o·-o· ~ E c,c:,cn: G-H SIDE Elecc1ton, BUILDII-JG G-H STREET o· ~ ·· c· I ·8" 1 -C le I, I, I, :il(::~~2-~_c;11 "i-;-;-" Ea, ,c'. ,n BUILDING I & L REAR ::: 1 e\r0: ::::,n: & L SIDE . ·-~ 1,-d -c· I, " I, I, i,c E1e,"1;u,1 BUILDING J & K REAR 1,,,mtcin: J & K SIDE 1 5" ,· -/' l/S '" I. I. I, i,, I, I, Ele-.,c1lion: & L STREET , a· 1 -o 1. 1,, .c,'.,''+ ...... ... -,,,.,,, ,I •U-0~ :t,;r~ --"' '""'j .,0·4~ ~ ~:::t'4 ----c -!II .. _" ~·· ~I ,,;.,-~ tlf., Jt,,,. BUILDING J & K STF,EET , ,e -1'--,J lo I, 1 ~-I,, (/) t, w t:: :,: u j ~ 1 l _, I 6 i (J '!) "' C, -11 . ' ~f ~.~ ,z [a::: "i 1=! ' 0 "' i"l . (/):,: zl 0 ""' ~~~ Ci C, _j ci ffi ~ CH•O A301 CA NE 3td Ct. R-lO(P) R-10 R~B ; Pel U) Q) > <,: N ~ ;:. 0 Ill Ill RMH ::::> ~ R-8 z .., ~ IQ .... "' ... RMH (P) E6 · 10 T23N R5E W 1/2 . NE 4th g_£JJ CA J '----CA NE Jtt:0St. ,--------~ ~--~i:.:i~ r---;c.---,--,,---j CA ~ CA z CA R-1 0 ~ s ;.\ ( ;:; /-'+-,......,.... CA R-10 "' I -0 q R-8 R-10 R-8 R-8 NE 21'R:JBS R-8 R-8· R-8 • RC(P) G6 · 22 T23N R5E W 1/2 ~ ZONING ----...... °"' limit, o 200 ·oo F6 uaoo ~ = TBCHNICAL SBR.VJCB8 15 T23N R5E W 1/2 5315 STATE OF WASHINGTON, COUNTY OF KING } AFFIDAVIT OF PUBLICATION PUBLIC NOTICE Jody L. Barton, being first duly sworn on oath that she is the Legal Advertising Representative of the King County Journal a daily newspaper, which newspaper is a legal newspaper of general circulation and is now and has been for more than six months prior to the date of publication hereinafter referred to, published in the English language continuously as a daily newspaper in King County, Washington. The King County Journal has been approved as a Legal Newspaper by order of the Superior Court of the State of Washington for King County. The notice in the exact form annexed was published in regular issues of the King County Journal (and not in supplement form) which was regularly distributed to its subscribers during the below stated period. The annexed notice. a Public Notice was published on November 27, 2006. The full amount of the fee charged for said foregoing publication is the sum of $150.75. -·-:,d)-«-> ·al Advertising Representative, King County Journal Subscribed and sworn to me this 27'h day of November, 2006. / ) ·c··.,.. '\ 'I--.~ B D Cantelon /-.;;-.I--;/,-, '-.(/. ;f(__,,~7,/ Notary Public for the State of Washington, Residing in Kent, Washington PO Number: NOTJCF; OF ENvlRONM~;NTAL DETERMINATIOJ\ ENVIROJ\MENTAL REVIEW COMMITTEE & PUBLIC HEARING HJ<;NTON, WASHINGTON The Environmental Review Com- mittee has issued a Determimtion of Non-Significance-Mitigat.ed for the following project unrln the authority of the Renton Municipal Code. Bremerton Townhomcs LlJA06-133. PP. CU-A, SA-A, ECF Location: 320 & 330 Bremerton Avenue KT Thf' appli('ant is n1qnc,sbng PrPlimir:nry Plat appruval. Sit<: Plan :,pprO\·,d, C(>11diti1_,nal L.~(' 1-hrnit appro- \';tl, :ind E11\·iro11me11!.;1l 1SF:P:\1 lli•vir!\\' t(, s11hrli\'irlf' an 1~xi:-ting 70,48l) sq11:1n1 font 11.R m.Tel :-=itc zorn,d (:omm('JTi,1] ,\rlt>rial iCi\l into 26 lot..c; for the future de- velopment of attached town- home units. The proposed lots would range from a minimum of 1,426 square feet to a mmrimum of 3.337 square feet in area. Two existing residencP~ on the proj0Ct site are proposed to be rf'movo?d. new townbomc units would be provided via a new internal public street system. Appeah> of the environmental determination mui.t be filed in writing on or before 5:00 PM on Docember 11, 2006. Appeals-must be filed in writing together with the required S7fi.OO application fee 'kith: Hem-ing Examiner, City of Rent.on, 1055 South Grady Way, Renton, WA 98055. ApJJeals to the Examiner arc governed by City of Renton Municipal Code Section 4-8-110.B. Additional information regarding th(~ appc~al process ma_v he obtained from the R.Pnh"m Cit~· ('lprk':c: Offivf'. r12S) 1:=!0- t):JIO. ,\ Public Hf•arini:: v,ill be hi'·ld by fr.(' Ht·nton Hl!anng Examiiwr in t.lw Cuuneil Chanclwi-,;. Cii\· ![all. 1m lkcPrnhn l!l. :2006 at. ;l:00 AM lo crm.~irlcr thr: (1n,Jiminary Pint. If the Environmental Determination is apJ)f'..aled, the appeal ·will be heard as part of this public hearing. Interested parties are invited to attend the public hearing. Publication Date: November 27, 2006 Published in the King County Journal Kovem!:*"r 27, 200l1. #8622(:i? The proposed Bremerton Ave. Townhome Plat is an application for a 26 lot single family attached residential subdivision situated on 2 existing lots with a total area of 1.80 acres. It is located on the east side of Bremerton Ave. NE. approximately 300' south of NE 4th St. This project will require preliminary plat approval, a conditional use permit, a site plan approval and a SEPA determination by the City of Renton. The site is zoned CA and is within the NE 4th St. Corridor Business District. The proposed product will be a attached townhomes with a mixture of 2 and 3 unit buildings. Each unit will have its own lot. The surrounding properties to the north, east and west are also similarly zoned CA. with the property to the south being zoned R-8. The site is currently has 2 existing residences. All of the existing houses and garages/sheds will be removed. Both of the existing houses have driveways connected to Bremerton Ave. NE. A recently constructed plat. Ridgeview Court. is adjacent to the site. across Bremerton Ave. NE to the west. There are no wetlands. steep slopes or any sensitive areas on this site. There is a low depression along the north property line. This depression is approx. 1 O' deep and extends off-site to the north. to the adjacent Bank drive-thru driveway. This depression will be filled. The depression was mostly formed by the filling of the property to the east. as the grading for an approved multi-family development. A grading easement will be obtained from the adjacent property (Bank) to fill their portion. The steepest slope is approx. 25% along the south bank of the depression, northwest of the existing northern house. There are some similar slopes along most sides of the depression. The soils on the site are a silty sand, with some and silt loam. The site is dominated by residential landscaping with few trees. There are approx. 30 trees that are spread throughout the plat. The existing drainage from the north half of the site sheet flows into the depression. The existing drainage from the south half of the site sheet flows to the southwest corner of the site. The proposed use of the property as a 26 lot attached town home residential subdivision will be consistent with the surrounding developments. All of the surrounding properties except for the parcels to the south, are developed. The proposed lots will range in size from the minimum of 1525 SF to a maximum of 4743 SF (including access and drainage easements). The density of the plat is 19.85 units per acre in the CA zone. Access to the new lots will be from a new internal public street that runs east/west and is connected to Bremerton Ave. NE. This street will • ' be provided with a hammerhead turnaround at the east end. There will be a short public road stub to the southeast with a private road extension to serve the southeastern portion of the development. The new streets are proposed to be 32' wide residential streets with a 42' right-of-way. The reduced ROW will be wide enough to accommodate the street and sidewalks on both sides. The reduced ROW width is needed to keep the net plat area at a maximum to stay under the maximum density. 2 private alleys will provide access to the buildings that front Bremerton Ave. NE. Bremerton Ave. NE is currently improved on the west side (by Ridgeview Court) but not on the east side. The proposed plat will construct the east side of the street to complete the full road section. A new water main and sewer main will be installed in the new plot street. The water main will be run through the site and connected to a future water main in the multi-family project to the east. The water and sewer service is provided by the City of Renton. The finished lots ore estimated to be worth approx. $150,000 for a total value of approx. 3.9 million dollars. The value of the lots with preliminary approval only is estimated to be $2.6 million dollars. The site will require substantial grading to bring the depression up to finished grade. The depression will need to be filled for approx. 8' in depth. The building pads for the lots will also require some minor grading but nothing over 4 feet. The main grading activity will be associated with the excavation for the detention vault and the fill for the depression. The estimated amount of grading is 500 CY for cut and 4000 CY for fill. It is anticipated that the site will use some of the cut material on-site, but the majority will be imported. There ore numerous trees on the site. There are approx. 30 trees on the site. Most of the trees will need to be removed due to conflicts with the roods, utilities and building pods. Land that will be dedicated to the City include the internal public roods and the public alley. The lots will be sold by the developer to one or several builders or investors. The future builders will likely use model homes and temporary job trailers. y. DE.NSITY . :. .;: ";. .;. •. ~ .,.· ~.;' ..... . ~ b ...... ~ WORKSHEET DEVELOPME.f'>JT PLA.NN!N - ('! !'"\/ o~· l·lCi'-ilO~! City of Renton Development Services Division 1055 South Grady Way-Renton, WA 98055 Phone: 425-430-7200 Fax: 425-430-7231 DEC O 6 2006 nECt:IVED 1. Gross area of property: 1. :z e ' 4 {cL, square feet ' 2. Deductions: Certain areas are excluded from density calculations. These include: Public streets .. Private access easements- Critical Areas* Total excluded area: 3. Subtract line 2 from line 1 for net area: 4. Divide line 3 by 43,560 for net acreage: 5. Number of dwelling units or Jots plznned: ! 5, LB~-square feet Co, 34J square feet · 0 square feet 2. Z.I, 532. square feet 3. Sto, 9-34 square feet 4. ! . 31 acres 6. Divide line 5 by line 4 for net density: 6. /<1, B5 • dwelling units/acre *Critical Areas~re defined as "Areas detennined by the City to be not suitable for development and which are subject to the City's Critical Areas Regulations including very high landslide areas, protected slopes, wetlands or floodways." Critical areas buffers are not deducted/excluded. ** Alleys (public or private) do not have to be excluded. / Q;\ \\ "EB\PW\DEV SERV\F orm:s\PJ.a.-..ni.,f.J~i~·-dvc 1 --,,~Y 0 o~,, ~ ·~ + ~-~ KathyKeolker,Mayor ~l'-ffO October 27. 2006 Michael Fortson Department of Transportation Renton School District 1220 N 4th Street Renton, WA 98055 Subject: Bremerton Avenue Townhomes LUA06-133, PP, SA-A, CU-A, ECF CIT~ :>F RENTON Planning/Building/Public Works Department Gregg Zimmerman P.E., Administrator The City of Renton Development Services Division has received an application for a 26-lot townhouse subdivision located at 320 & 330 Bremerton Avenue NE. Please see the enclosed Notice of Application for further details. In order to process this application, the Development Services Division needs to know which Renton schools would be attended by children living in residences at the location indicated above. Please fill in the appropriate schools on the list below and return this letter to my attention, Development Services Division, City of Renton, 1055 South Grady Way, Renton, Washington 98055 by November 10, 2006. Elementary School: --,<-Vlu.,'-""'¥:J=""'-~· ~·'-'--'--l..----~-'(."'Jec·"::..:'<.::..·J,__·-...c7-1-.,.t·:.1.·1""'··~· !...L-4'--"'"""--'..!.'.."'-Ll- / I ' Mid die School: _ _J._!__1.LJs::::p.~~1---'--'-"._:_·, "''· '--'-__ -_ __..../d.<4--i:+,..."...1<J.c .• ,,.,?c.O..L---"l.::.! ,f/~ae!.··~..;;"!.:.J±..'.!1(,_'-' High School: Y,,&t,C;x ),l'·:f i . . .. · /uk)::_ Will the schools you h:ve indicated be able to handle the impact of the additional students estimated to come from the proposed development? Yes X: No __ _ Any Comments: ___________________________ _ ----·· --· --------------- Thank you for proiliding this important information. If you have any questions regarding this project, please contact me at (425) 430-7219. Sincerely, {jJJ 1{ :£2· V !~-~; Ding ~ Senior Planner · V Encl. -------,-O-SS_S_o_u_th_Gr-ad_y_W_a_y ___ R_e-nt_o_n.-W-a-s-hi-ngt-on-9-80_5_5 ______ ~ @) This paper contains 50°;,, rP.cycled material, 30% post consumer AHEAD OF THE CURVE ENVIRONMENTAL DETERMINATION & PUBLIC HEARING ISSUANCE OF A DETERMINATION OF NON-SIGNIFICANCE -MITIGATED (DNS-M) POSTED TO NOTIFY INTERESTW PERSONS OF AN ENVIRONMENTAL ACTION PROJECT NAME: Bremerton Avenue Townhomes PROJECT NUMBER: LUA06,133, PP, CU-A, SA-A, ECF LOCATION: 320 & JJD Bremerton Avenue NE DESCRIPTION: The applicant is requesting Prelimlnary Plat approval, Site Plan approval, Conditional Use Permit approval, and Environmental (SEPAi Review to subdivide an existing 78,466 square foot (1.8 acre) aite zon&d Commen:lal Arterial ICA) ;ntc 26 lots for the future development of attached townhome units. The proposed lots would range from a minimum of 1,426 square IHI to a maximum of 3,337 square feet in area. Two emting rasldencas on tha project site are proposed to be removed. Access to the new town home units would ba provided via a new Internal pl.lblic street system. THE CITY OF RENTON ENVIRONlvlENTAL REVIEW COMMITIEE {ERC) HAS DETERMINED THAT THE PROPOSED ACTION DOES NOT HAVE A SIGNIFICANT ADVERSE IMPACT ON THE ENVIRONMENT Appo1ls of the environmental determination mt1sl be filed in writing on or before 5:DD PM on December 11, 2D06. Apl"'ale must be filed In writing together with the requir~d $75.DO applh::atlon fee with: Hearing Eumlner, City of R1nton, 1D55 South Grady Way, Renton. WA 98055. App.ala to the Enmlner are governed by City of Renton Municipal Code Section 4-8-110.B. Addl\lonJI Information regarding Iha eppul procaee may ba obtained lrom Iha Renton City Clerk's Office, (425) 430-651 D DEVELOPMENT CERTIFICATION I, ~ 6t=:.1~ hereby certify that 3, copies of the above docume~''"""''''' were posted by me in > conspicuous places or nearby the described property oll:"'~~'~.,!Jt11 --~ :::"'",9-.,.\6!·' •--:·.!, ,.,.,,,, -,,.1.~' ,,1,1~"JI: SIGNED: ~ :::SlJ/,1. ._<.,,J./;. ~',, ~ -;;,'-~;¢-... ·"if,,... \}/~ ~ ,<:(:;,_, .-,:: ~ ~ ~u ,;;z~ A TrEST· Subscnbed and sworn before me, a Notary Pub he, 1n and for the State of Washington res1dmg m ; t /':J ".f.J jo: '/ "i U8v ~ .. ~ - DATE: J/-Z-]· .o., ~+='"· 1...a~w1~C~ __ ,, on the olJ' t, day of b-,c ,. ,. ll'> l:o.'::'.) I 1,,ui),,,,J <-19 ... ,.F~.# /1, "1 111\H\\\\\*~$ F W~~,," !\\111\\"''" CITY OF RENTON CURRENT PLANNING DIVISION AFFIDAVIT OF SERVICE BY MAILING On the 22'0 day of November, 2006, I deposited in the mails of the United States, a sealed envelope containing ERC Determination documents. This information was sent to: Name Representina Agencies See Attached Eric LaBrie Contact Marc Rousso Applicant Alice Knight Owner Trustee for Violet Bliss Estate Charles Ratzsch Owner k /' / (Signature of Sender),.;_: ___,,..<}(fo-· ~ . ..,..C"".-l*"{___,\,--,=h,._C..:c({"-'-/t_. '-'---------- STATE OF WASHINGT~N ) {J ) ss COUNTY OF KING ) I certify that I know or have satisfactory evidence that Stacy Tucker signed this instrument and acknowledged it to be his/her/their free and voluntary act for !Q_~Ustli~f1nd purposes mentioned in the instrument. ;:-1f \ '(~!%~~111l -$· ·,L •,'.i'J/'11" ~ Dated: " / ;;y7 /olt =:;.,,, .-_ · ',, !. <,,,,, ~ ashing\oo < ~ , , ;;_ - Notary (Print):_r:A11,""-'---'..'.'..d.)s:.t.1.(_. --'L~'l+;-O;u\...:'"''---')-.\c-"'-..J.9!+-'-'1'-'""-'-""'-''-"'---·;-'l:,.,.:,'~..,;.'-",,".,.,..._ •:...0.,, :...,· •. .,,_;."-·'"'-·"~{c.:t~==--- My appointment expires: 0 -1 '\ -1 u ' '111,'li,' .;, ,:.::", :·~0_;f" Project Name: Bremerton Avenue Townhomes Project Number: LUA06-133, PP, CU-A, SA-A, ECF template -affidavit of service by mailing ; I JI J Of. V,i t=\ 3~~~~~' lf\\\\\\\S'"-', I Dept. of Ecology' 1 Environmental Review Section PO Box 47703 Olvmoia, WA 98504-7703 AGENCY (DOE) LETTER MAILING (ERC DETERMINATIONS) WDFW -Stewart Reinbold ' Muckleshoot Indian Tribe Fisheries Dept. c/o Department of Ecology Attn: Karen Walter or SEPA Reviewer 3190 160th Ave SE 39015 -172"' Avenue SE Bellevue, WA 98008 Auburn, WA 98092 ' WSDOT Northwest Region ' Duwamish Tribal Office ' Muckleshoot Cultural Resources Program • Attn: Ramin Pazooki 4717 W Marginal Way SW Attn: Ms Melissa Calvert King Area Dev. Serv., MS-240 Seattle. WA 98106-1514 39015 172"' Avenue SE PO Box 330310 Auburn, WA 98092-9763 Seattle, WA 98133-971 O US Army Corp. of Engineers • KC Wastewater Treatment Division * Office of Archaeology & Historic Seattle District Office Environmental Planning Supervisor Preservation* Attn: SEPA Reviewer Ms. Shirley Marroquin Attn: Stephanie Kramer PO Box C-3755 201 S. Jackson ST, MS KSC-NR-050 PO Box48343 Seattle, WA 98124 Seattle, WA 98104-3855 Olvmoia, WA 98504-8343 Jamey Taylor • Depart. of Natural Resources PO Box 47015 Olvmoia, WA 98504-7015 KC Dev. & Environmental Serv. City of Newcastle City of Kent Attn: SEPA Section Attn: Mr. Micheal E. Nicholson Attn: Mr. Fred Satterstrom, AICP 900 Oakesdale Ave. SW Director of Community Development Acting Community Dev. Director Renton, WA 98055-1219 13020 SE 72"' Place 220 Fourth Avenue South Newcastle, WA 98059 Kent, WA 98032-5895 Metro Transit Puget Sound Energy City of Tukwila Senior Environmental Planner Municipal Liason Manager Steve Lancaster, Responsible Official Gary Kriedt Joe Jainga 6300 Southcenter Blvd. 201 South Jackson Street KSC-TR-0431 PO Box 90868, MS: XRD-01W Tukwila, WA 98188 Seattle, WA 98104-3856 Bellevue, WA 98009-0868 Seattle Public Utilities State Department of Ecology Real Estate Services NW Regional Office Title Examiner 3190 160th Avenue SE 700 Fifth Avenue, Suite 4900 Bellevue, WA 98008-5452 PO Box 34018 Seattle, WA 98124-4018 Note: If the Notice of Application states that it is an "Optional DNS", the marked agencies and cities will need to be sent a copy of the checklist, PMT's, and the notice of application. • Also note, do not mail Jamey Taylor any of the notices she gets hers from the web. Only send her the ERG Determination paperwork. template . affidavit of service by mailing ENVIRONMENTAL DETERMINATION & PUBLIC HEARING ISSUANCE OF A DETERMINATION OF NON-SIGNIFICANCE -MITIGATED (DNS-M) POSTED TO NOTIFY INTERESTED PERSONS OF AN ENVIRONMENTAL ACTION PROJECT NAME: Bremerton Avenue Townhomes PROJECT NUMBER: LUAOS-133, PP: CU-A, SA-A, ECF LOCATION: 320 & 330 Bremerton Avenue NE DESCRIPTION: The applicant is requesting Preliminary Plat approval, Site Plan approval, Conditional Use Permit approval, and Environmental (SEPA) Review to subdivide an existing 78,466 square foot (1.8 acre) site zoned Commercial Arterial (CA) into 26 lots for the future development of attached townhome units. The proposed lots would range from a minimum of 1,426 square feet to a maximum of 3,337 square feet in area. Two existing residences on the project site are proposed to be removed. Access to the new townhome units would be provided via a new internal public street system. THE CITY OF RENTON ENVIRONMENTAL REVIEW COMMITIEE (ERC) HAS DETERMINED THAT THE PROPOSED ACTION DOES NOT HAVE A SIGNIFICANT ADVERSE IMPACT ON THE ENVIRONMENT. Appeals of the environmental determination must be filed ·iri writing on or before 5:00 PM on December 11, 2006. Appeals must be filed In writing together with the required $75.00 application fee with: Hearing Examiner, City of Renton, 1055 South Grady Way, Renton, WA 98055. Appeals to the Examiner are governed by City of Renton Municipal Code Section 4-8-110.B. Additional information regarding the appeal process may be obtained from the Renton City Clerk's Office, (425) 430-6510 .. November 22, 2006 Eric LaBrie ESM Consulting Engineers 33915 1st Ways #200 Federal Way. WA 98003 SUBJECT: Dear Mr. LaBrie: Bremerton Avenue Townhomes LUA06-133, PP, CU-A, SA-A, ECF CIT"\: :>F RENTON Planning/Building/Public Works Department Gregg Zimmerman P.E., Administrator This letter is written on behalf of the Environmental Review Committee (ERC) to advise you that they have completed their review of the subject project and have issued a threshold Determination of Non- Significance-Mitigated with Mitigation Measures. Please refer to the enclosed ERC Report and Decision, Section C for a list _of the Mitigation Measures. Appeals of the environmental determination must be filed in writing on or before 5:00 PM on December 11, 2006. Appeals must be filed in writing together with the required $75.00 application fee with: Hearing Examiner, City of Renton, 1055 South Grady Way, Renton, WA 98055. Appeals to the Examiner are governed by City of Renton Municipal Code -Section 4-8-110.8. Additional information regarding the appeal process may be obtained from the Renton City Clerk's Office, (425) 430-6510. A Public Hearing will be held by the Renton Hearing Examiner in the Council Chambers on the seventh floor of City Hall, 1055 South Grady Way, Renton, Washington, on December 19, 2006 at 9:00 AM to consider the Preliminary Plat. The applicant or representative(s) of the applicant is required to be present at the public hearing. A copy of the staff report will be mailed to you one week before the hearing. If the Environmental Determination is appealed, the appeal will be heard as part of this public hearin·g. · The preceding information will assist you in planning for implementation of your project and enable you to exercise your appeal rights more fully, if you choose to do so. If you have any questions or desire clarification of the above, please call me at (425) 430-7219. For the Environmental Review Committee, /, 1{.;J)~ ng 11 Senior Planner V cc: Charles Ratzsch, Alice Knight-Trustee for Violet Bliss Estate / Owner(s) Marc Rousso, Seattle Redevelopment LLC / Applicant Enclosure -------IO_S_S _So_u_th_Gra_d_y_W_a_y_--R-en-to_n_, -W-as-h-in-gt-on-9-80_5_5 ______ ~ @ This paper contains 50% recycled material, 30% post consumer AHEAD OF THE CURVE November 22, 2006 Washington State Department of Ecology Environmental Review Section PO Box47703 Olympia, WA 98504-7703 CIT"l'. )F RENTON Planning/Building/Public Works Department Gregg Zimmerman P.E., Administrator Subject: Environmental Determinations Transmitted herewith is a copy of the Environmental Determination for the following project reviewed by the Environmental Review Committee (ERC) on November 20, 2006: DETERMINATION OF NON-SIGNIFICANCE -MITIGATED PROJECT NAME: PROJECT NUMBER: LOCATION: DESCRIPTION: Bremerton Avenue Townhomes LUA06-133, PP, CU-A, SA-A, ECF 320 & 330 Bremerton Avenue NE The applicant is requesting Preliminary Plat approval, Site Plan approval, Conditional Use Permit approval, and Environmental (SEPA) Review to subdivide an existing 78,466 square foot (1.8 acre) site zoned Commercial Arterial (CA) into 26 lots for the future development of attached townhome units. The proposed lots would range from a minimum of 1,426 square feet to a maximum of 3,337 square feet in area. Two existing residences on the project site are proposed to be removed. Access to the new townhome units would be provided via a new internal public street system. Appeals of the environmental determination must be filed in writing on or before 5:00 PM on December 11, 2006. Appeals must be filed in writing together with the required $75.00 application fee with: Hearing Examiner, City of Renton, 1055 South Grady Way, Renton, WA 98055. Appeals to the Examiner are governed by City of Renton Municipal Code Section 4-8-11 O.B. Additional information regarding the appeal process may be obtained from the Renton City Clerk's Office, (425) 430-6510. If you have questions, please call me at (425) 430-7219. For the Environmental Review Committee, cJ_)J 1{. j2u· {?"~ill K. Ding Senior Planner cc: King County Wastewater Treatment Division WDFW, Stewart Reinbold David F. Dietzman, Department of Natural Resources WSDOT, Northwest Region Duwamish Tribal Office Karen Walter, Fisheries, Muckleshoot Indian Tribe (Ordinance) Melissa Calvert, Muckleshoot Cultural Resources Program US Army Corp. of Engineers Stephanie Kramer, Office of Archaeology & Historic Preservation -l::oclosum----,-0-55_S_o_u_th_G_r_ad_y_W-ay---R-e-n-to-n,-W-as-h1-.n-gt-on-9-80-5-5-------~ @ This paper contains 50% recycled m;iterial. 30% post consumer AHEAD OF THE CURVE CITY OF RENTON DETERMINATION OF NON-SIGNIFICANCE-MITIGATED !I/IJJIGATION MEASURES APPLICATION NO(S): APPLICANT: PROJECT NAME: LUA-06-133, PP, CU-A, SA-A, ECF Marc Rousso, Seattle Redevelopment LLC Bremerton Townhomes DESCRIPTION OF PROPOSAL: The applicant is requesting Preliminary Plat approval, Site Plan approval, Conditional Use Permit approval, and Environmental (SEPA) Review to subdivide an existing 78,466 square foot (1.8 acre) site zoned Commercial Arterial (CA) into 26 lots for the future development of attached townhome units. The proposed lots would range from a minimum of 1,426 square feet to a maximum of 3,337 square feet in area. Two existing residences on the project site are proposed to be removed. Access to the new townhome units would be provided via a new internal public street system. LOCATION OF PROPOSAL: LEAD AGENCY: MITIGATION MEASURES: 320 & 330 Bremerton Avenue NE The City of Renton Department of Planning/Building/Public Works Development Planning Section 1. The applicant shall comply with the recommendations found in the geotechnical report prepared by Earth Solutions NE, LLC, dated July 19, 2006. 2. The applicant shall be required to provide a Temporary Erosion and Sediment,;ition Control Plan (TESCP) designed pursuant to the Department of Ecology's Erosion and Sediment Control Requirements outlined in Volume II of the Stormwater Management Manual and provide staff with a Construction Mitigation Plan prior to issuance of Construction Permits. This condition shall be subject to the review and approval of the Development Services Division. 3. The detention system for this project shall be required to comply with the requirements found in the 2005 King County Surface Water Design Manual to meet both c:Jetention (Conservation Flow control -a.k.a. Level 2) and water quality improvements. 4. The applicant shall pay a Parks Mitigation Fee based on $530.76 per each new single family lot. 5. The applicant shall pay a Traffic Mitigation Fee in the amount of $75 for each new net daily trip prior to the recording of the final plat. It is anticipated that the proposed project would result in the payment of $9,991.50 (152 net new daily trips x $75 = $9,991.50). 6. Staff recommends that the applicant pay a Fire Mitigation Fee based on $388.00 per new single family lot prior to the recording of the final plat. The fee is estimated at $9,312 ($388 x 24 = $9,312). ERC Mitigation Measures Page 1 of 1 I CITY OF RENTON DETERMINATION OF NON-SIGNIFICANCE-MITIGATED ADVISORY NOTES APPLICATION NO(S): APPLICANT: PROJECT NAME: LUA-06-133, PP, CU-A, SA-A, ECF Marc Rousso, Seattle Redevelopment LLC Bremerton Townhomes DESCRIPTION OF PROPOSAL: The applicant is requesting Preliminary Plat approval, Site Plan approval, Conditional Use Permit approval, and Environmental (SEPA) Review to subdivide an existing 78,466 square foot (1.8 acre) site zoned Commercial Arterial (CA) into 26 lots for the future development of attached townhome units. The proposed lots would range from a minimum of 1,426 square feet to a maximum of 3,337 square feet in area. Two existing residences on the project site are proposed to be removed. Access to the new townhome units would be provided via a new internal public street system. LOCATION OF PROPOSAL: LEAD AGENCY: 320 & 330 Bremerton Avenue NE The City of Renton Department of Planning/Building/Public Works Development Planning Section Advisory Notes to Applicant: The following notes are supplemental information provided in conjunction with the environmental determination. Because these notes are provided as information only, they are not subject to the appeal process for environmental determinations. Planning 1. RMC section 4-4-030.C.2 limits haul hours between 8:30 am to 3:30 pm, Monday through Friday unless otherwise approved by the Development Services Division. 2. Commercial, multi-family, new single family and other nonresidential construction activities shall be restricted to the hours between seven o'clock (7:00) a.m. and eight o'clock (8:00) p.m., Monday through Friday. Work on Saturdays shall be restricted to the hours between nine o'clock (9:00) a.m. and eight o'clock (8:00) p.m. No work shall be permitted bii Sundays. 3. Within thirty (30) days of completion of grading work, the applicant shall hydroseed or plant an appropriate ground cover over any portion of the site that is graded or cleared of vegetation and where no further construction work will occur within ninety (90) days. Alternative measures such as mulch, sodding, or plastic covering as specified in the current King County Surface Water Management Design Manual as adopted by the City of Renton may be proposed between the dates of November 1st and March 31st of each year. The Development Services Division's approval of this work is required prior to final inspection and approval of the permit. 4. A detailed landscape plan complying with the requirements set forth under RMC 4-8-120D shall be submitted at the time of Final Plan review for review and approval by the Development Services Division Project Manager. Fire 1. The preliminary fire flow is 2,500 gpm for attached units 13-15 and 16-18 and 1,750 gpm for the rest of the units. One hydrant is required within 150 feet of each structure and one additional hydrant for all the units except attached units 13-15, and 16-18 which require two additional hydrants within 300 feet of the structures. 2. Separate plans and permits are required for the installation of sprinkler and fire alarm systems. 3. Fire Department access roadways are required to within 150 feet of all portions of the building exteriors. ERC Advisory Notes Page 1 of 3 I , 4. Fire Department access roadways over 150 feet in length are required to have an approved turnaround. 5. A site plan for pre-fire planning is required to be submitted to the Fire Department for your project. 6. All fire lanes shall be constructed using an all-weather driving surface constructed of asphalt or reinforced concrete certified capable of supporting a 30-ton vehicle and 322 psi loading. Plan Review -Surface Water 1. The applicant is responsible for obtaining any and all necessary easements required for the storm design. 2. Surface Water System Development Charge is $759 per new dwelling unit. This fee is due with the construction permit. Plan Review -Water 1. All of the units are required to be sprinklered. This project is required to install an 8-inch water main connected to the existing main in Bremerton Avenue NE looped through the site in the public right-of-way and connected back to the main in Bremerton Avenue NE. In addition the main shall be extended to the east and connect to the existing water main (W3024). The main shall also be extended to the south in the private street to the south property line in a 15· foot easement to the City of Renton. The City of Renton code dictates that the lateral spacing of fire hydrants shall be predicated on hydrants being located at street intersections. The utility plan needs to be modified to show fire hydrants at both north and south portion of the public right-of-way and also a fire hydrant near building six. 2. Each unit requires a separate service line and meter which will serve domestic and fire. The size is determined by a certified fire sprinkler designer but shall be a minimum of one inch. 3. Any new construction shall have a fire hydrant capable of delivering a minimum of 1,000 gpm with one hydrant located within 150 feet of the structure and two additional hydrants located within 300 feet of the structure. This distance is measured al,ong the travel route. 4. System Development Charges are $1,956.00 per dwelling unit. The Development Charges are collected as part of the construction permit. Please note that any parcel that currently has water and or sewer service is eligible for a prorated system development charge. Your project will be reviewed to determine how much redevelopment credit applies. Plan Review -Sanitary Sewer 1. A sanitary sewer main extension is required to be installed by this project. 2. The applicant shall install individual site sewers to serve the project. 3. This site is located within the East Renton Special Assessment District (SAD 0002). These fees are $316.80 per unit and paid prior to issuance of a construction permit. 4. The Sewer System Development Charge is $1,017 per new dwelling unit. This fee is due with the construction permit. Please note that any parcel the currently has water and or sewer service is eligible for a prorated system development charge. Your project will be reviewed to determine how much redevelopment credit applies. Plan Review -Transportation 1. The project shall install street improvements to include curb, gutter, sidewalk, and street lighting if not existing. All street lighting shall be per City of Renton standards and specifications. Plan Review -General 1. All required utility, drainage, and street improvements will require separate plan submittals prepared according to City of Renton drafting standards by a licensed Civil Engineer. ERC Advisory Notes Page 2 of 3 2. All plans shall be tied to a minimum of two of the City of Renton current Horizontal and Vertical Control Network. 3. Permit applications must include an itemized cost estimate for these improvements. The fee for review and inspection of these improvements is 5% of the first $100,000 of the estimated construction costs; 4% of anything over $100,000 but less than $200,000, and 3% of anything over $200,000. Half of the fee must be paid upon application for building and construction permits, and the remainder when the permits are issued. There may be additional fees for water service related expenses. See Drafting Standards. Property Services 1. To be sent under separate cover. ERC Advisory Notes Page 3 of-3 CITY OF RENTON DETERMINATION OF NON-SIGNIFICANCE (MITIGATED) APPLICATION NO(S): LUA-06-133, PP, CU-A, SA-A, ECF APPLICANT: Marc Rousso, Seattle Redevelopment LLC PROJECT NAME: Bremerton Townhomes DESCRIPTION OF PROPOSAL: The applicant is requesting Preliminary Plat approval, Site Plan approval, Conditional Use Permit approval, and Environmental (SEPA) Review to subdivide an existing 78,466 square foot (1.8 acre) site zoned Commercial Arterial (CA) into 26 lots for the future development of attached townhome units. The proposed lots would range from a minimum of 1,426 square feet to a maximum of 3,337 square feet in area. Two existing residences on the project site are proposed to be removed. Access to the new townhome units would be provided via a new internal public street system. LOCATION OF PROPOSAL LEAD AGENCY: 320 & 330 Bremerton Avenue NE The City of Renton Department of Planning/Building/Public Works Development Planning Section The City of Renton Environmental Review Committee has determined that it does not have a probable significant adverse impact on the environment. An Environmental Impact Statement (EIS) is not required under RCW 43.21C.030(2)(c). Conditions were imposed as mitigation measures by the Environmental Review Committee under their authority of Section 4-6-6 Renton Municipal Code. These conditions are necessary to mitigate environmental impacts identified during the environmental review process. Appeals of the environmental determination must be filed in writing on or before 5:00 PM on December 11, 2006. Appeals must be filed in writing together with the required $75.00 application fee with: Hearing Examiner, City of Renton, 1055 South Grady Way, Renton, WA 98055. Appeals to the Examiner are governed by City of Renton Municipal Code Section 4-8-110.8. Additional information regarding the appeal process may be obtained from the Renton City Clerk's Office, (425) 430-6510. PUBLICATION DATE: DATE OF DECISION: SIGNATURES: Terry Higashiyama, Administrator Community Services November 27, 2006 November 20, 2006 I I /! ... b:2 !(} 6 Date 11-hc Ice;; Dale ' . David Daniels, Fire Chief Fire Department ~~~vV) A~. Adriifurator EDNSP ~ ENVIRONMENT AL REVIEW COMM ITT-EE---- MEETING NOTICE November 20, 2006 To: Gregg Zimmerman, Planning/Building/Public Works Administrator Terry Higashiyama, Community Services Administrator I. David Daniels, Fire Chief Alex Pietsch, EDNSP Administrator From: Jennifer Henning, Development Planning . . ·· .. Meeting Date: Monday, November 20, 2006 Time: 3:00 PM .: . Location; Sixth Floor Conference Room #620 . . Agenda listed below. Laurelhurst Division 3 Preliminary Plat (Higgins/ LUA06-131, PP, ECF The proponent of the Laurelhurst Division 3 Preliminary Plat is requesting SEPA environmental review and Preliminary Plat approval for subdivision of 2.4 acres of land into 14 lots suitable for single-family residential development. The property is currently used for a single-family residence. It is zoned Residential 8 (R-8). The lots would be developed at a density of 7.86 dwelling units per net acre (du/a). The lots would range in size from approximately 4,800 sq ft to 7,700 sq ft. Bremerton Townhomes (Ding) LUA06-133, CU-A, SA-A, ECF The applicant is requesting Preliminary Plat approval, Site Plan approval, Conditional Use Permit approval, and Environmental (SEPA) Review to subdivide an existing 78,466 square foot (1.8 acre) site zoned Commercial Arterial (CA) into 26 lots for the future development of attached townhome units. The proposed lots -would range from a minimum of 1,426 square feet to a maximum of 3,337 square feet in area. Two existing residences on the project site are proposed to be removed. Access to the new town home units would be provided via a new internal public street system. cc: K. Keolker, Mayor J. Covington, Chief Administrative Officer S. Dale Estey, EDNSP Director® J. Gray, Fire Prevention N. Watts, P/8/PW Development Services Director ® F. Kaufman, Hearing Examiner S. Engler, Fire Prevention ® J. Medzegian, Council P. Hahn, P/B/PW Transportation Systems Director R. Lind, Economic Development L. Warren, City Attorney ® STAFF REPOR-T-- City of Renton Department of Planning I Building 1-P--Ub!ic Works ENVIRONMENTAL REVIEW COMMITTEE A. BACKGROUND ERC MEETING DA TE Project Name: Applicant: File Number: Project Manager: Project Description: Project Location: Exist. Bldg. Area gsf: Site Area: RECOMMl=NDA TION: Project Location Map November 20, 2006 Bremerton Townhomes Seattle Redevelopment LLC, Marc Rousso LUA-06-133, CU-A, ECF, SA-A, pp Jill K. Ding, Senior Planner The applicant is requesting Preliminary Plat approval, Site Plan approval, Conditional Use Permit approval, and Environmental (SEPA) Review to subdivide an existing 78,466 square foot (1.8 acre) site zoned Commercial Arterial (CA) into 26 lots for the future development of attached townhome units. The proposed lots would range from a minimum of 1,426 square feet to a maximum of 3,337 square feet in area. Two existing residences on the project site are proposed to be removed. Access to the new townhome units would be provided via a new internal public street system. (Project Description continued on next page). 320 & 330 Bremerton Avenue NE (parcel nos. 152305-9193 & 152305-9035) N/A Proposed New Bldg. Area: Approx. 2,500 78,466 sf (1.8-acres) Total Building Area gsf' square feet per unit 65,000 square feet Staff recommends that the Environmental Review Committee issue a Determination of Non-Significance -Mitigated (DNS-M). ercrpt_bremertontownhomes City of Renton P/8/PW Department BREMERTON TOWNHOMES REPORT OF November 20, 2006 A. PROJECT DESC.~lf'.TION (CONT.) E nmental Review Committee Staff Report LUA06-133, CU-A, ECF, SA-A PP Page 2of7 The proposal would result in the construction of 26 attached townhome units on 26 lots. The project would be composed of two 3-unit structures and ten 2-unit structures. The project site is located on the east side of Bremerton Avenue NE and is zoned Commercial Arterial (CA) and is also located within the NE 4th Street Corridor Business District. Two existing residences and associated outbuildings are proposed to be removed from the project site. The applicant contends that no critical areas are located on the project site. The City's critical areas maps have identified a Class 4 stream that would be located in the vicinity of the project site; however the applicant has provided a stream study indicating that there is no stream in the vicinity of this site. A low depression is located along the north property line in the vicinity of where the City's maps identify a stream. The depression is approximately 10 feet deep and extends off-site to the north. The applicant indicates that the depression was created as a result of grading that was done on the property to the east as apart of a multi-family residential development. The proposal would include filling the depression. A grading easement would be obtained to fill off-site portions of the depression. The project would result in approximately 500 cubic yards of cut and 4,000 cubic yards of fill. The majority of the grading required for the project would be for the excavation of the detention vault and fill for the depression. All cut material is proposed to be used on-site. The existing drainage from the north half of the project site sheet flows across the site and into the depression. The drainage from the south half of the project site sheet flows to the southwest corner of the site. Access to the proposed lots would be provided via a new looped internal public street off of Bremerton Avenue NE. A private street would provide access off of the new public street to the south east corner of the project site. Eight joint use driveways are proposed to be placed within access easements to provide access to the majority of the 2-unit town home structures. B. RECOMMENDATION Based on analysis of probable impacts from the proposal, staff recommends that the Responsible Officials make the following Environmental Determination: .DETERMINATION OF NON-SIGNIFICANCE Issue DNS with 14 day Appeal Period. Issue DNS with 15 day Comment Period with Concurrent 14 day Appeal Period. C. MIT/GA TION MEASURES DETERMINATION OF XX NON -SIGNIFICANCE· MIT/GA TED. XX Issue DNS-M with 14 day Appeal Period. Issue DNS-M with 15 day Comment Period with Concurrent 14 day Appeal Period. 1. The applicant shall comply with the recommendations found in the geotechnical report prepared by Earth Solutions NE, LLC, dated July 19, 2006. 2. The applicant shall be required to provide a Temporary Erosion and Sedimentation Control Plan (TESCP) designed pursuant to the Department of Ecology's Erosion and Sediment Control Requirements outlined in Volume II of the Stormwater Management Manual and provide staff with a Construction Mitigation Plan prior to issuance of Construction Permits. This condition shall be subject to the review and approval of the Development Services Division. 3. The detention system for this project shall be required to comply with the requirements found in the 2005 King County Surface Water Design Manual to meet both detention (Conservation Flow control - a.k.a. Level 2) and water quality improvements. ercrpt_bremertontownhomes City of Renton P/8/PW Department BREMERTON TOWNHOMES REPORT OF November 20, 2006 E ,mental Review Committee Staff Report LUAOG-133, CU-A, ECF, SA-A, PP Page 3 of 7 4. The applicant shall pay a Parks Mmg_ation Fee based on $530.76 per each new single familyJot. 5. The applicant shall pay a Traffic Mitigation Fee in the amount of $75 for each new net daily trip prior to the recording of the final plat. It is anticipated that the proposed project would result in the payment of $9,991.50 (152 net new daily trips x $75 = $9,991.50). 6. Staff recommends that the applicant pay a Fire Mitigation Fee based on $388.00 per new single family lot prior to the recording of the final plat. The fee is estimated at $9,312 ($388 x 24 = $9,312). D. ENVIRONMENTAL IMPACTS In compliance with RCW 43.21 C. 240, the following project environmental review addresses only those project impacts that are not adequately addressed under existing development standards and environmental regulations. 1. Earth With the project application, the applicant submitted a Geotechnical Report prepared by Earth Solutions NW, LLC, dated July 19, 2006. According to the report the site topography is relatively level with the exception of the depression area located along the northern portion of the project site. Vegetation on the project site consists primarily of mature landscaping. According to a referenced geologic map, the site is underlain with glacially consolidated till deposits. The King County Soil Survey identifies Alderwood gravelly sandy loam (AgC) as underlying the project site. The applicant's geotechnical engineer excavated 5 test pits throughout the site. The submitted geotech report states that relatively consistent soil and groundwater conditions were encountered throughout the project site. Topsoil was encountered in the top four to 12 inches of soil, however deeper areas of topsoil could exist on-site due to variable topographic changes. Fill was encountered in the next three to four feet of soil in Test Pits 4 and 5 and consisted of loose silty sand with gravel fill containing trace to moderate amounts of debris and organics. Underlying the topsoil and fill, native soils were encountered in all of the test pits. The native soils consisted of silty sand and silty sand with gravel soils in topographically higher areas and sand and gravel in topographically lower areas. Groundwater was encountered at depths of 7 Y, to 8 feet below existing grade in Test Pits 4 and 5. The geotech report concludes that the soil conditions found during the fieldwork generally correlated with the geologic map designation and the King County Soil Survey with the exception of the conditions found along the northern portion ·of the prop.erty, which consisted of recessional outwash type sand and gravel deposits. The report provided recommendations for site preparation and earthwork, excavation and slopes, rockeries and modular block walls, utility trench backfill, pavement sections, foundations, slab-on-grade floors, retaining walls, and drainage. Due to the potential for impacts that could occur during construction, staff recommends as a mitigation measure that construction of the project be required to comply with the recommendations found in the geotechnical report prepared by Earth Solutions NW, LLC, dated July 19, 2006 that was submitted with the project application. The applicant's SEPA checklist indicates that earthwork activities are estimated at 500 cubic yards of cut and 4,000 cubic yards of fill. The majority of the grading would result from the excavation of the stormwater detention vault and the fill required for the depression area located along the northern portion of the project site. Due to the potential for erosion to occur from the subject site, staff recommends a mitigation measure that requires the applicant to comply with the Department of Ecology's Erosion and Sediment Control Requirements as outlined in Volume II of the Stormwater Management Manual. Mitigation Measures: 1. The applicant shall comply with the recommendations found in the geotechnical report prepared by Earth Solutions NE, LLC, dated July 19, 2006. ercrpLbremertontownhomes City of Renton P/BIPW Department BREMERTON TOWNHOMES REPORT OF November 20, 2006 E ,mental Review Committee Staff Report LUA06-133, CU-A, ECF, SA-A, PP Page 4 of 7 2. The applicant shall be required to provid_e_9_Temporary Erosion and Sedimentation Control PJ!,t_ri_ (TESCP) designed pursuant to the Department of Ecology's Erosion and Sediment Control Requirements outlined in Volume 11 of the Stormwater Management Manual and provide staff with a Construction Mitigation Plan prior to issuance of Construction Permits. This condition shall be subject to the review and approval of the Development Services Division. Nexus: SEPA Environmental Regulations 2. Water -Stormwater A Preliminary Technical Information Report prepared by Jaeger Engineering, dated September 29, 2006 was submitted with the application materials. According to the report the existing drainage from the north half of the site sheet flows into the depression. The existing drainage from the south half of the site sheet flows to the southwest corner of the site. The proposed method of drainage control as indicated by the storm drainage report would be a detention vault and wetvault located near the southeast corner of the project site underneath the proposed private street. The City's Plan Review Section has reviewed the submitted drainage report. Due to downstream drainage problems, staff recommends a mitigation measure that would require the project to comply with the 2005 King County Surface Water Design Manual to meet both detention (Conservation Flow control -a.k.a. Level 2) and water quality improvements. The report and design submitted with the application appear to have complied with the 2005 design requirements. Mitigation: The detention system for this project shall be required to comply with the requirements found in the 2005 King County Surface Water Design Manual to meet both detention (Conservation Flow control - a.k.a. Level 2) and water quality improvements. Nexus: SEPA Environmental Regulations, King County Surface Water Design Manual 3. Plants The site is currently vegetated with 42 significant trees and mature landscape areas. A total of 3 of the existing significant trees are proposed to be retained on the central portion of the project site. The remainder of trees would be removed for the construction of building pads, roadways, the stormwater vault, and the installation of utility lines. A total of 25 percent of existing trees are required to be retained or replaced on-site. The proposal to retain 3 trees would result in a retention rate of 7 percent. A total of 8 2-inch caliper trees will be required to be planted to comply with the significant tree retention/replacement requirements. Mitigation: No further mitigation is recommended Nexus: SEPA Environmental Regulations 4. Recreation The proposal does not provide on-site recreation areas for future residents of the proposed plat. However, a pedestrian trail easement is proposed to connect to the R-8 zoned properties to the east. It is anticipated that the proposed development would generate future demand on existing City parks and recreational facilities and programs. Therefore, staff recommends a mitigation measure requiring that the applicant pay a Parks Mitigation Fee based on $530. 76 per each new single-family lot. The fee is estimated at $12,738.24 (24 new lots (credit given for existing residences) x $530.76 = $12,738.24) and is payable prior to the recording of the final plat. Mitigation: The applicant shall pay a Parks Mitigation Fee based on $530.76 per each new single family lot. Nexus: SEPA Environmental Regulations ercrpt_bremertonto'IMlhomes City of Renton P/8/PW Department BREMERTON TOWNHOMES REPORT OF November 20, 2006 5. . _Tr!!nsportation Et ,mental Review Committee Staff Report LUA06-133, CU-A, ECF, SA-A, PP Page 5 of 7 Access to the project would be provided via a "looped" residential access road off of Bremerton Avenue NE. The City's street standards require that residential access roads have a right-of-way width of 42 feet with 32 feet of paving, sidewalks, curb and gutter, and street lighting. A modification has been approved to permit a 30-foot wide public street with 28 feet of paving, sidewalks, curb and gutter, and street lighting. A Traffic Impact Analysis (TIA) prepared by Gibson Traffic Consultants, dated September 27, 2006 was submitted with the project application. According to the TIA, the proposed project would result in the addition of 152 new average daily trips. It is anticipated that the proposed project would result in impacts to the City's street system. Therefore, staff recommends a mitigation measure requiring the payment of a Traffic Mitigation Fee in the amount of $75 for each new net daily trip prior to the recording of the final plat. It is anticipated that the proposed project would result in the payment of $9,991.50 (152 net new daily trips x $75 = $9,991.50). Mitigation: The applicant shall pay a Traffic Mitigation Fee in the amount of $75 for each new net daily trip prior to the recording of the final plat. It is anticipated that the proposed project would result in the payment of $9,991.50 (152 net new daily trips x $75 = $9,991.50). Nexus: SEPA Environmental Regulations 6. Emergency Services The proposal will add new residential units to the City that will potentially impact the City's Police and Fire Emergency Services. Staff recommends a mitigation measure requiring the applicant to pay a Fire Mitigation Fee, based on $388.00 per new lot prior to the recording of the final plat. The fee is estimated at $9,312 ($388 X 24" $9,312). Mitigation: Staff recommends that the applicant pay a Fire Mitigation Fee based on $388.00 per new single family lot prior to the recording of the final plat. The fee is estimated at $9,312 ($388 x 24 = $9,312). Nexus: SEPA Environmental Regulations E. COMMENTS OF REVIEWING DEPARTMENTS The proposal has been circulated to City Departmental I Divisional Reviewers for their review. Where applicable, these comments have been incorporated into the text of this report as Mitigation Measures and/or Advisory Notes to Applicant. ..){_ Copies of all Review Comments are contained in the Official File. __ Copies of all Review Comments are attached to this report. Environmental Determination Appeal Process Appeals of the environmental determination must be filed in writing on or before 5:00 p.m. December 4, 2006. Appeals must be filed in writing together with the required $75.00 application fee to: Hearing Examiner, City of Renton, 1055 South Grady Way, Renton. WA 98055. Appeals to the Examiner are governed by the City of Renton Municipal Code Section 4-8-110.B. Additional information regarding the appeal process may be obtained from the Renton City Clerk's Office at (425) 430-6510. Advisory Notes to Applicant: The following notes are supplemental information provided in conjunction with the environmental determination. Because these notes are provided as information only, they are not subject to the appeal process for environmental determinations. Planning 1. RMC section 4-4-030.C.2 limits haul hours between 8:30 am to 3:30 pm, Monday through Friday unless otherwise approved by the Development Services Division. 2. Commercial, multi-family, new single family and other nonresidential construction activities shall be restricted to the hours between seven o'clock 7:00 a.m. and ei ht o'clock 8:00 .m., Monda throu h ercrpt_bremertontownhomes City of Renton P/8/PW Department BREMERTON TOWNHOMES E nmental Review Committee Staff Report LUAOG-133, CU-A ECF, SA-A, PP REPORT OF November 20, 2006 Page 6017 Friday. Work Q!L~turdays shall be restricted to the hours between .Oiosl o'clock (9:00) a.m. and eight o'clock (8:00) p.m. No work shall be permitted on Sundays. 3. Within thirty (30) days of completion of grading work, the applicant shall hydroseed or plant an appropriate ground cover over any portion of the site that is graded or cleared of vegetation and where no further construction work will occur within ninety (90) days. Alternative measures such as mulch, sodding, or plastic covering as specified in the current King County Surface Water Management Design Manual as adopted by the City of Renton may be proposed between the dates of November 1st and March 31st of each year. The Development Services Division's approval of this work is required prior to final inspection and approval of the permit. 4. A detailed landscape plan complying with the requirements set forth under RMC 4-8-120D shall be submitted at the time of Final Plan review for review and approval by the Development Services Division Project Manager. Fire 1. The preliminary fire flow is 2,500 gpm for attached units 13-15 and 16-18 and 1,750 gpm for the rest of the units. One hydrant is required within 150 feet of each structure and one additional hydrant for all the units except attached units 13-15, and 16-18 which require two additional hydrants within 300 feet of the structures. 2. Separate plans and permits are required for the installation of sprinkler and fire alarm systems. 3. Fire Department access roadways are required to within 150 feet of all portions of the building exteriors. 4. Fire Department access roadways over 150 feet in length are required to have an approved turnaround. 5. A site plan for pre-fire planning is required to be submitted to the Fire Department for your project. 6. All fire lanes shall be constructed using an all-weather driving surface constructed of asphalt or reinforced concrete certified capable of supporting a 30-ton vehicle and 322 psi loading. Plan Review -Surface Water 1. The applicant is responsible for obtaining any and all necessary easements required for the storm design. 2. Surface Water System Development Charge is $759 per new dwelling unit. This fee is due with the construction permit. Plan Review -Water 1. All of the units are required to be sprinklered. This project is required to install an 8-inch water main connected to the existing main in Bremerton Avenue NE looped through the site in the public right-of- way and connected back to the main in Bremerton Avenue NE. In addition the main shall be extended to the east and connect to the existing water main (W3024 ). The main shall also be extended to the south in the private street to the south property line in a 15-foot easement to the City of Renton. The City of Renton code dictates that the lateral spacing of fire hydrants shall be predicated on hydrants being located at street intersections. The utility plan needs to be modified to show fire hydrants at both north and south portion of the public right-of-way and also a fire hydrant near building six. 2. Each unit requires a separate service line and meter which will serve domestic and fire. The size is determined by a certified fire sprinkler designer but shall be a minimum of one inch. 3. Any new construction shall have a fire hydrant capable of delivering a minimum of 1,000 gpm with one hydrant located within 150 feet of the structure and two additional hydrants located within 300 feet of the structure. This distance is measured along the travel route. 4. System Development Charges are $1,956.00 per dwelling unit. The Development Charges are collected as part of the construction permit. Please note that any parcel that currently has water and or sewer service is eligible for a prorated system development charge. Your project will be reviewed to determine how much redevelopment credit applies. Plan Review Sanitary Sewer 1. A sanitary sewer main extension is required to be installed by this project. 2. The applicant shall install individual site sewers to serve the project. ercrpt_bremertontownhomes City of Renton P/BIPW Department BREMERTON TOWNHOMES REPORT OF November 20, 2006 E ,mental Review Committee Staff Report LUA06-133, CU-A, ECF, SA-A PP Page 7 of 7 3. This site is located withinJtie_East Renton Special Assessment District (SAD 09.Q;?). These fees are $316.80 per unit and paid prior to issuance of a construction permit. 4. The Sewer System Development Charge is $1,017 per new dwelling unit. This fee is due with the construction permit. Please note that any parcel the currently has water and or sewer service is eligible for a prorated system development charge. Your project will be reviewed to determine how much redevelopment credit applies. Plan Review -Transportation 1. The project shall install street improvements to include curb, gutter, sidewalk, and street lighting if not existing. All street lighting shall be per City of Renton standards and specifications. Plan Review -General 1. All required utility, drainage, and street improvements will require separate plan submittals prepared according to City of Renton drafting standards by a licensed Civil Engineer. 2. All plans shall be tied to a minimum of two of the City of Renton current Horizontal and Vertical Control Network. 3. Permit applications must include an itemized cost estimate for these improvements. The fee for review and inspection of these improvements is 5% of the first $100,000 of the estimated construction costs; 4% of anything over $100,000 but less than $200,000, and 3% of anything over $200,000. Half of the fee must be paid upon application for building and construction permits, and the remainder when the permits are issued. There may be additional fees for water service related expenses. See Drafting Standards. Property Services 1. To be sent under separate cover. ercrpt_bremertontownhomes NG COUNTY :PAATMENT of ASSESSMENTS t - • , " - • !. • ,i , ,- • • • ., ~""'~"' ~ ~~sf. ~~l'l, .... u<i<\o~ 4 , ~-, t ,,.J : ::J ; .• j), • ,:. ~ • :!' -=-~ .::: . ;;;:· \ I \.-..---·-! I I _J 1' .!! ·. ,11 \ ··-lj /MARTIN'r L.AC~· "~'~_,__:::::.·_;· \ .. ~; j TRACTS UNREC. ·-,~ , ' • ' I Scala ,,1:.0011· • 100"1 .,._ ---... ,31,:rooo I. .. , • • • ,. . , , = - ,. .-, !.· ~ ~-i l ' -, i • ' I ~· ' • ., 2. r .,s11,,1 ••••• 1 i I 'f .. z !" I ·•~t=~~--~-~~§ . ' ii SSl~iiU!iHHf I ' ---~ I \ i \ ~ • 0 • I I . ---~ I • -0 -~1· nr I I :wJH g ,. I f'H! a ~-111 ,.;, • p,:1!: I ' ·~ !ii :, ~ ii HU • I! I I r . 11! ~I• ii ii i I Ii 111 ' l • /3RDIERTON A\£. TO'MJH0M£S (I)"~ -JAEGER ENGINEERING 26 wrs _ 94'! .. ~~ 204~~ PREUMJNARY PU. T UAP ,,,_. ""'-rmJ ~O!»f JJQ .le .J20 fJROJERTON A'£. NE I i-,@-f far-(25.!")mo--m.li.'I i """'"" "''"·"' E9 . .,, ' ~a ~ .-V> =i m )> I! 0 0 " ['1 ' i..1 ' :gj ~ i i1 ' ,, j! ! ,! I I ! ., ~ ' SITE PLAN AIOO ----~= --------- DRISCOLL ARCHITECTS ·----.......... h.OOm 1,5 B•IJ s1, .. ,~seo1tlo WA 98121 20ti•441•77o5~206•H1•5373 (fax) ""'"'_., .......... _.,."'°"'.,.,_"_,, _ _ ,.,.,,.,.,.,w ..._..,. __ J ______________ J BREMERTON AVE. __ ! __________ _ ,- " lz .~ le, i~ .n I' I -l~q n !O SEATTLE REDEVELOPMENT, LL.C. . , ! ~ ' " '::: ' ' BREMERTON TO HOMES ~ i " ' CITY OF" l>E~TCl'I PREUf.llNARY LANDSCAPE PLAN lll'SHl"GTON . ~---... ~~---::: rED ""'"''' '''"""' '" I j !tED :=.;~"t,!~~ 1 e I• 1q,1 J .. ww.nmcMl.com :r? .. -15! :;;;.;,~'".;... .. "" I ~~ I t=.._-:;:.. __ ,• ! > ' 0 ~ 6 z 0 " ,' m z ~ ~ 0 " -; I m z ~ -~ " m ~ 0 z Elevotic1: A REAR 1/8" m 1°-()" Elevation A SIDE Elevation: A STREET 1/1;'' " 1·-0· 1/B" • 1'-(l" I, L· 'a 1,. lo I.· l,t· la I,· lo· Elevot:on: B-F REAR 1/s·· ~ I -0 Elevutiori: B-F SIDE Flevation B-F STREET 1/B" ~ 1'-D" 1/tl" • 1·-0 I., I, I.. I ,~ Io I,· I~ I ,. lo I,· lo· loo- --~~.:r.~ j ~"-""'l .,c-cT ~ . -s'.;ci'·t -, .. _,.. 1 .o·-a-~ IC Iv.TC· -,·,.--:; .(• """'' -.-,<.>O- -~{~"~ V) >-u w !:: I ~ ~ ... J j l 0 ! u V) °' 0 ~ l i tll: t z 0 >- "' w wsi ::, < w• QC a CD~ I,. I "' !Q~ g .. ~g _,_, w"' A30C D C ~ ~ ~ C -:;,'~ .,a-a· . -•''-'"t.·' ~~-~~ Elevoboo BUILDING G-H REAR JJIU)L:f: _____ ==:JHljjLJm:-----::::m ----· l=-d! JUL _OE~~ F1evotion G-H SIDE Elevation: BUILDING G-H STREET _,_,. I/~·· i' -0 1/a-~ ,· _ o· 1/8" -,· -o· lo I, I,. lo Is l,a lo • I. I,. 1' Ele·votion: BUILDING & L REAR Elevation: I & L SIDE 1/B'" I -0' 1/8" ~ 1· .. o· lo I, Is I,. I, 1,-I, 1., [levotic-1 BUILDING J & K REAR fie'-ot,m, J & K SIDE , .·P.' I -0 1/B -,·-o· la I, le· I, la 1,-I,· '" E1evction BUILDING 1/8' ~ 1·-0· ,o I,· la I,, • & L STREET 'I r11_ --~~'{}~ ''c,/'- . ./' --'.~'-~'-"!~ .~.~~ j ~'.· -"'"l. .,a-e~ ~ JI ~tA:2-0 _,, . ..,_. ~ •0-0"~ clPvo'.ion. BUILDING J & K STREET I /8' ~ I ·-,1" I~ I~ '" V> ,_ u w 5 J ~ "j ::J I 0 u !!:> "' Cl ' ' ! : ! [;; 11! ij'' ' . z 0 ~ ... ·w ~; :E !,:' • l l,J <( § I~~] v,I zl 0 "'"' ~en~ ~gJ ~ ffi S! A.301 E6 · 10 T23N R5E W 1/2 · NE 4th SL CA CA · NE Jllf 0sv. CA CA R-lOCP) ,., I. f-------1 ·-. R-10. R~B Q.) > < . i:: 0 RMH CP) Q RCCP) CA R-10 "'1 V------:C~A--,--~ Z R-1 R-8 R;....8 "'1 · R--sz Q.) -~ "O ~ Q.) ·- R-10 R-8 G6 · 22 T23N RSE W 1/2 ~ ZONING ----"""'••""'Um! .. ~ = Tl!CHNICAL SBRVICBS o 200 tyo F6 .1='800 15 T23N R5E W 1/2 5315 ~y ~~~~~ ' f, >+, + .a + ~~ 2; Kathy Keolker, Mayor ?z.NcrO CITY )F RENTON Planning/Building/Public Works Department Gregg Zimmerman P.E., Administrator November 14, 2006 Eric LaBrie ESM Consulting Engineers 33915 1" Way S, Suite 200 Federal Way, WA 98003 ' RE: Bremerton Townhomes Review Comments (File No. LUA06-133, PP, SA-A, CU- A, ECF) Dear Mr. LaBrie: The first review of your submittal for the Bremerton Townhomes project has been completed. Revisions to the proposed preliminary plat layout and a revised density worksheet are required in order to continue processing the preliminary plat. The City's street standards for private streets (RMC 4-6-060J) state that "Private streets are allowed for access to six or fewer lots, provided at least two of the six lots abut a public right-of-way. Private streets will only be permitted if a public street is not anticipated by the Planning/Building/Public Works Department to be necessary for existing or future traffic and/or pedestrian circulation through the subdivision or to serve adjacent property." This section further requires that the minimum easement width for a private street be 26 feet wide with 20 feet of paving. The proposed preliminary plat layout identifies a 24-foot width private street, which is 2 feet less than the minimum width required. The preliminary plat layout shall be revised to widen the private street to the minimum required 26-foot width. In addition, the private street shall be extended to the southern property line to serve as secondary access for future development of the parcel to the south. Please note that staff is looking into potentially requiring the dedication of the private street as a public right-of way and this may become a condition of preliminary plat approval. The City's street standards for shared driveways (RMC 4-6-060K) state that "A shared private driveway may be pem1itted for access to two lots. The private access easement shall be a minimum of20 feet in width, with a minimum of 12 feet of paving." The proposed preliminary plat layout identifies 12-foot wide shared driveway easements serving the proposed duplex structures, which is 8 feet less than the minimum width required. The preliminary plat layout shall be revised to widen the proposed 12-foot wide shared driveway easements to 20 feet in width with 12 feet of paving. -------l-05_5_S_o_u_th_G_r_ad_y_W_a_y ___ R_e-nt-on-.-W-a-s-hi-ng_t_on-98_0_5_5-------'--'-~ @ This paper contains 50'% recycled material. 30% post consumer AHEAD OF THE CURVE • The required revisions to the proposed private street and shared driveway easements would affect the density of the proposed project and would likely result in a reduction in the number of lots that may be permitted. A revised density worksheet including the revised private access easement areas shall be submitted with the revised preliminary plat map. Please submit 3 copies and 1 reduced 8 Y2 by 11 inch PMT of a revised preliminary plat map and 3 copies of a revised density worksheet. If these items are not submitted by November 30, 2006, then your project will be placed on hold and the public hearing scheduled for December 19, 2006 will have to be rescheduled. If you have any questions, feel free to contact me at ( 425) 430-7219. Sincerely, c·· 1i ;J2· L.,. U Semor Planner cc: Owners Applicant DATE: TO: FROM: SUBJECT: CITY OF RENTON MEMORANDUM November 6, 2006 Jill Ding Amela Henninger X7298 BREMERTON AVE TOWNHOMES APPLICATION LUA 06-133 320 & 330 BREMERTON A VE NE I have reviewed the application for 26 lots for the development of attached townhome units all located in Section 15, Twp. 23N, Rng. 5 E and have the following comments: Existing Conditions Water --The project site is located in the 565 Water Pressure Zone. The static pressure at the street level is approximately 70 psi. There is an existing 8" watermain located in Bremerton Ave NE (see City of Renton drawing W-3260 for detailed engineering plans). Sanitary Sewer --There is an existing 8" sanitary sewer main in Bremerton Ave NE (see City of Renton drawing S-3260 for detailed engineering plans). There is an existing 8" sanitary sewer main on the north and east side of this site. Storm --There are storm drainage facilities in Bremerton Ave NE. The site is located in Aquifer Protection Zone 2 and may be subject to additional requirements per City code. CODE REQUIREMENTS Street Improvements: • The project shall install street improvements to include curb, gutter, sidewalk and street lighting if not existing. All street lighting shall be per City of Renton standards and specifications. • The Traffic Mitigation fee of $9991.50 applies to this project. Storm Drainage: • This site drains to the Maplewood Creek. Due to downstream flooding and erosion problems, staff is recommending a SEPA condition requiring this project to comply with the 2005 King County Surface Water Design Manual to meet both detention (Conservation Flow control -a.k.a. Level 2) and water quality improvements. • The applicant is responsible for obtaining any and all necessary easements required for the storm design. .. Bremerton Tov,rn Homes Application • The project will be required to pay the Surface Water System Development Charges of $759 per new unit prior to the issuance of the construction permit. Water: • Per the City of Renton Fire Marshal th<: preliminary fire flow is 2500 GPM for attached units 13- 15 and 16-18 and 1750 GPM for the remainder of the units. All of the buildings are required to be sprinklered. This project is required to install an 8" watermain connected to the existing main in Bremerton Ave NE looped through the site 111 the public right of way and connected back to the main in Bremerton Ave NE. In addition the marn shall be extended to the east and connect to the existing water main (W3024). The main shall also be extended to the south in the private street to the south property line in a 15' easement to the City of Renton. The City of Renton code dictates that the lateral spacing of fire hydrants shall be predicated on hydrants being located at street intersections. The utility plan needs to be modified to show fire hydrants at both north and south public right of way streets and also a fire hydrant near building six. • Each unit requires a separate service line and meter which will serve domestic and fire. The size is determined by a certified fire sprinkler designer but shall be a minimum of one inch .. • Any new construction must have a fire hydrant capable of delivering a minimum of 1,000 GPM with one hydrant located within 150 feet of the structure and two additional hydrants located within 300 feet of the structure. This distance is measured along the travel route. • System Development Charges are $1956.00 per dwelling unit. The Development Charges are collected as part of the construction permit. Please note that any parcel that currently has water and or sewer service is eligible for a prorated system development charge. Your project will be reviewed to determine how much redevelopment credit applies. Sanitary Sewer: • A sanitary sewer main extension is required to be installed by this project. • The applicant shall install individual sidesewers to serve the project. • This site is located in the East Renton Special Assessment District (SAD 0002). These fees are $316.80 per unit and paid prior to issuance of a construction permit. • System Development Charges are $1017.00 per dwelling unit. The Development Charges are collected as part of the construction permit. Please note that any parcel that currently has water and or sewer service is eligible for a prorated system development charge. Your project will be reviewed to determine how much redevelopment credit applies. General: • All required utility, drainage and street improvements will require separate plan submittals prepared according to City of Renton drafting standards by a licensed Civil Engineer. • All plans shall be tied to a minimum of two of the City of Renton current Horizontal and Vertical Control Network. • Permit application must include an itemized cost estimate for these improvements. The fee for review and inspection of these improvements is 5% of the first $100,000 of the estimated construction costs; 4% of anything over $100,000 but less than $200,000, and 3% of anything over $200,000. Half of the fee must he paid upon application for building and construction permits, and the remainder when the permits are issued. There may be additional fees for water service related expenses. See Drafting Standards. City"· .. enton Department of Planning I Building I Pu Works ENVIRONMENTAL & DEVELOPMENT APPLICATION REVIEW SHEET REVIEWING DEPARTMENT: Pion Kev1r· { . COMMENTS DUE: NOVEMBER 10, 2006 APPLICATION NO: LUA06-133, PP, SA-A, CU-A, ECF DATE CIRCULATED: OCTOBER 27, 2006 ·1 . .i' APPLICANT: Marc Rousso PROJECT MANAGER: Jill Dinn RECEIVt:U PROJECT TITLE: Bremerton Avenue Townhomes PLAN REVIEW: fig,:,/ ETA OCl 3 SITE AREA: 1.8 acres BUILDING AREA (nrossl: 2,200 sauare feat Mr unil LOCATION: 320 & 330 Bremerton Avenue NE I WORK ORDER NO: 77667 uo,,,_u m.C U• <>O, "--'" SUMMARY OF PROPOSAL: The applicant is requesting Preliminary Plat approval, Site Plan approval, Conditional Use Permit approval, and Environmental (SEPA) Review to subdivide an existing 78,466 square foot (1.8 acre) site zoned Commericial Arterial (CA) into 26 lots for the future development of attached townhome units. The proposed lots would range from a minimum of 1,426 square feet to a maximum of 3,337 square feet in area. Two existing residences on the project site are proposed to be removed. Access to the new townhome units would be provided via a new internal public street system. A. ENVIRONMENTAL IMPACT (e.g. Non-Code) COMMENTS Element of the Probable Probable More Element of the Probable Probable More EnWronment Minor Major Information Impacts Impacts Necessary Environment Minor Major Information Impacts Impacts Necessary Earth Housinn Air Aesthetics Water Linht/Glare Plants Recreation Land/Shoreline Use Utilities Animals Trans ation Environmental Health Public Services Energy! Histodc/Cultural Natural Resoun:;es Preservation Airport Environment 10,000 Feet 14,000 Feet B. POLICY-RE.LA TED COMMENTS C. CODE-RE.LA TED COMMENTS ~,~(f2ztl ~~ '.., We have reviewed this application with particular attention to those areas in which we have expertise and have identified areas of probable impact or areas where addition I information is needed to p operly assess this proposal. . ~ , ~ t_// Date j L -----------------------~----------------------------- · · ·~ -·, -~-c!:,)~T:Jt})f, ,,; , -\_-_t -~--i'·< r ~~ ~ ,_____ -------------------~-"""--------------~-------------------~--. Project Name: Project Address: Contact Person: Permit Number: fz~e;V\,\~µ A--0-, ::Towl)hoM~? 3;;).0 . -I 330 :B(2.b"l-l8(l;r00 {\Ve. !\JG M Pi:1<.G e.o us.so Project Description: ;;ty lh,J\Gl,\G""I> Sf: TDWU ~I.AG'S, '*24\;;;,';, fD BC l?i.,,A,\:,v-ae -::: Method of Calculation: Land Use Type: d Residential O Retail p-rrE Trip Generation Manual, 7th Edition 0 Traffic Study O Other .~ 0 Non-retail ,,O<Jlcul~tfQ11::. ;.;..1-.:,:-~.: :----- , ('?JP).(~~) eo.Jo /T?Jwn l'"Ou'K., . S.t'>C,,/urv,, .. :-~·1.- l~j.,.~l,o <:t~~ ·' y '). ~\\ "' . . . . ~ . ·. . ' .. (33. ;).";>- tf . . . . . . ·133-~ y.7<; -'_ >·°'·)~_q \,SO· ... .• . -... j. •'J"ransportatlon ,r1 , · · · ·, .Mli:igatlon_Fee: ~. q) q qi 1 $ 0 ('J-~ ~l~ufate.d by: ¥) .. ~\~iJu . Dlite:._.:..:ti-1,.:/0=+/?JN'R.;;..:..:c·-I' .. -: ....._,____ ;/ .· D11ci:e-:ottav.ment: ==:::'.:========::;;::::.:::==-=-=·:::~--------~- . •.z. City . . enton Department of Planning I Building I Pu • Works ENVIRONMENTAL & DEVELOPMENT APPL/CATION REVIEW SHEET REVIEWING DEPARTMENT:j(I~Dr;r+a:11, l \ COMMENTS DUE: NOVEMBER 10, 2006 ' APPLICATION NO: LUA06-133, PP, SA-A, CU-A, ECF DATE CIRCULATED: OCTOBER 27, 2006 . '' "., ' ' ., ' APPLICANT: Marc Rousso PROJECT MANAGER: Jill Dina R F ,-F i \I ~ r, PROJECT TITLE: Bremerton Avenue Townhomes PLAN REVIEW: Juliana Fries ~, .. SITE AREA: 1.8 acres BUILDING AREA lnross): 2,200 sau-;,re'fe:t ~ef~/<R LOCATION: 320 & 330 Bremerton Avenue NE WORK ORDER NO: 77667 BUILDING DIVISION SUMMARY OF PROPOSAL: The applicant is requesting Preliminary Plat approval, Site Plan approval, Conditional Use Permit approval. and Environmental (SEPA) Review to subdivide an existing 78,466 square foot (1.8 acre) site zoned Commericial Arterial (CA) into 26 lots for the future development of attached town home units. The proposed lots would range from a minimum of 1,426 square feet to a maximum of 3,337 square feet in area. Two existing residences on the project site are proposed to be removed. Access to the new townhome units would be provided via a new internal public street system. A. ENVIRONMENTAL IMPACT (e.g. Non-Code) COMMENTS Element of the Probable Probable More Element of the Probable Probable More Environment Minor Major Information Impacts Impacts Necessary Environment Minor Major Information Impacts Impacts Necessary Earth Housina Air Aesthetics Water Uaht!Glare Plants Recreation Land/Shoreline Use Utilities Animals Transnn."ation Environmental Health Public Services Energy! Historic/Cultural Natural Resources Preservation Airport Environment 10,000 Feet 14,000 Feet B. POL/CY-RELATED COMMENTS C. CODE-RELATED COMMENTS We have reviewed this application with particular attention to those areas in which we have expertise and have identified areas of probable impact or areas w; re additional information is needed to properly assess this proposal. Date DATE: TO: FROM: SUBJECT: MITIGATION ITEMS: FIRE DEPARTMENT MEMORANDUM October 30, 2006 Jill Ding, Associate Planner I {J;! James Gray, Assistant Fire Marshajt /~ Bremerton Townhouses, 330 BremiJ;~~ Ave NE I. A fire mitigation fee of$10,088.00 is required based on $388.00 per unit. FIRE CODE REQUIREMENTS: I. The preliminary fire flow is 2500 GPM for attached units 13-15 and 16-18 and 1750 GPM for the rest of the units. One hydrant is required with 150 feet of each structure and one additional hydrant for all the units except attached unit13-15, 16-18 which require two additional hydrants within 300 feet of the structures. 2. Separate plans and permits are required for the installation of sprinkler and fire alarm systems. 3. Fire Department access roadways are required to within 150 of all portions of the building exteriors. 4. Fire department access roadways over 150 feet in length are required an approved turnaround. 5. A site plan for Pre-fire planning is required to be submitted for your project. This shall be submitted prior to occupancy, in one of the attached formats. Please feel free to contact me if you have any questions. i:\bremertontownerc.doc I PRE-FIRE PLANNING I RENTON FIRE DEPARTMENT In an effort to streamline our pre-fire process, we are requesting that you submit a site plan of your construction project in one of the following formats which we can then convert to VISIO.vsd. This is required to be submitted prior to occupancy. ------ ABC Flowcharter.af3 ABC Flowcharkr.at2 Adobe Illustrator File.ai AutoCad Drm'_ing.dwg AutoCad Drawing.dgn -·--·-- Computer Graphics Mctafile.cgm Corel Clioart Forrnal.cmx Corel ORA WI Drawin_g File Format.edr Corel Flow.cfl J_I1capsulated Postscript File.cps Enhanced Metafile.emf IGES Drawing File Forrnat.igs Graohics Interchange Format.gif Macintosh PICT Format.pct ~~- Micrografx Designer Ver 3. l .drw Micrografx Designer Vei-6.0.dsf ~rostation Drawing.dgn Portable Network Graphics Format.pnf Postscriot File.ps ... ----- Tag Image Fil_e Format.tif Text.Ix! 1-------...------- Text.csv ~- VISIO.vsd - Windows Bitmap.bmp Windows Bitmap.dib Windows Mctafile.wmf Zsoft PC Paintbrush Bitmap.pcx • City<., .. enton Department of Planning I Building I Pu., ... Works ENVIRONMENTAL & DEVELOPMENT APPLICATION REVIEW SHEET REVIEWING DEPARTMENT: COMMENTS DUE: NOVEMBER 10, 2006 APPLICATION NO: LUA06-133, PP, SA-A, CU-A, ECF DATE CIRCULATED: OCTOBER 27, 2006 APPLICANT: Marc Rousso PROJECT MANAGER: Jill Din' PROJECT TITLE: Bremerton Avenue Townhomes PLAN REVIEW: Juliana Fries SITE AREA: 1.8 acres BUILDING AREA ross : 2,200 s LOCATION: 320 & 330 Bremerton Avenue NE I WORK ORDER NO: 77667 SUMMARY OF PROPOSAL: The applicant is requesting Preliminary Plat approval, Site Plan approval, Conditional. Use Permit approval, and Environmental (SEPA) Review to subdivide an existing 78,466 square foot (1.8 acre) site zoned CommericfafArterial (CA) into 26 lots for the future development of attached townhome units. The proposed lots would range from a minimum of 1,426 square feet to a maximum of 3,337 square feet in area. Two existing residences on the project site are proposed to be removed. Access to the new townhome units would be provided via a new internal public street system. A. ENVIRONMENTAL IMPACT (e.g. Non-Code) COMMENTS Element of the Probable Probable Mo,e Element of the Probable Probable Mo,e Environment Minor Major Information Impacts Impacts Necessary Environment Minor Major Information Impacts Impacts Necessary Earth Housina Air Aesthetics Water Liaht!Glare Plants Recreation Land/Shoreline Use Utilities Animals Transnnrtation Environmental Health Public Services Energy/ Histodc/Cultural Natural Resources PreseNation Airport Environment 10,000 Feet 14,000 Feet 8. POL/CY-RELATED COMMENTS I)/! C. CODE-RELATED COMMENTS City _ .. _enton Department of Planning I Building I Pu Vorks ENVIRONMENTAL & DEVELOPMENT APPLICATION REVIEW SHEET REVIEWING DEPARTMENT: VrJ rkS COMMENTS DUE: NOVEMBER 10, 2006 APPLICATION NO: LUA06-133, PP, SA-A, CU-A, ECF DATE CIRCULATED: OCTOBER 27, 2006 APPLICANT: Marc Rousso PROJECT MANAGER: Jill Dina PROJECT TITLE: Bremerton Avenue Townhames PLAN REVIEW: Juliana Fries SITE AREA: 1.8 acres BUILDING AREA lnross): 2,200 sauare feet oer unit LOCATION: 320 & 330 Bremerton Avenue NE WORK ORDER NO: 77667 SUMMARY OF PROPOSAL: The applicant is requesting Preliminary Plat approval, Site Plan approval, Canditianal Use Permit approval, and Environmental (SEPA) Review ta subdivide an existing 78,466 square foot (1.8 acre) site zoned Cammericial Arterial (CA) inta 26 lots far the future development of attached town home units. The proposed lots would range from a minimum of 1,426 square feet ta a maximum of 3,337 square feet in area. Two existing residences on the project site are proposed to be removed. Access to the new townhome units would be provided via a new internal public street system. A. ENVIRONMENTAL IMPACT (e.g. Non-Code) COMMENTS Element of the Probable Probable More Element of the Probable Probable More Environment Minor M1'Jor Information Impacts Impacts Necessary Environment Minor Major Information Impacts Impacts Necessary Earth Housina Air Aesthetics Water Uaht/Gfare Plants Recreation Land/Shoreline Use Utilities Animals Transrv1rtation Environmental Health Public Services Energy/ Historic/Cultural Natural Resources Preservation Airport Environment 10,000 Feet 14,000 Feet B. POLICY-RELATED COMMENTS C. CODE-RELATED COMMENTS We have reviewed this application with particular attention to those areas in which we have expertise and have identified areas of probable impact or areas where additional informaUon is nee d to properly assess this proposal. A. ENVIRONMENTAL IMPACT (e.g. Non-Code) COMMENTS "It is anticipated that the proposed development would generate future residents that would utilize existing City park and recreation facilities and programs. The City has adopted a Parks Mitigation Fee of $530.76 per each new single family lot to address these potential impacts." Parks Mitigation Fee City ,,. enton Department of Planning I Building I Pu.., .. c Works ENVIRONMENTAL & DEVELOPMENT APPLICATION REVIEW SHEET REVIEWING DEPARTMENT: C:Tr, ;J,,, 1 rJ1nr. COMMENTS DUE: NOVEMBER 10, 2006 \,I, Y 'Jt ,,i , I, APPLICATION NO: LUA06-133, PP, SA-A, CU-A, ECF DATE CIRCULATED: OCTOBER 27, 2006R EC EI Vt: D APPLICANT: Marc Rousso PROJECT MANAGER: Jill Dinq nr1 ., ~ PROJECT TITLE: Bremerton Avenue Townhomes PLAN REVIEW: Juliana Fries SITE AREA: 1.8 acres BUILDING AREA laross): 2,200 square f.§Jii!IJ.l~ DIVISIOI, LOCATION: 320 & 330 Bremerton Avenue NE I WORK ORDER NO: 77667 SUMMARY OF PROPOSAL: The applicant is requesting Preliminary Plat approval, Site Plan approval, Conditional Use Permit approval, and Environmental (SEPA) Review to subdivide an existing 78,466 square foot (1.8 acre) site zoned Commericial Arterial (CA) into 26 lots for the future development of attached townhome units. The proposed lots would range from a minimum of 1,426 square feet to a maximum of 3,337 square feet in area. Two existing residences on the project site are proposed to be removed. Access to the new townhome units would be provided via a new internal public street system. A. ENVIRONMENTAL IMPACT (e.g. Non-Code) COMMENTS Element of the Probable Probable More Element of the Probable Probable More Environment Minor Major Information Impacts Impacts Necessary Environment Minor Major Information Impacts Impacts Necessary Earth Housino Air Aesthetics Water Uoht!G/are Plants Recreation Land/Shoreline Use Utilities Animals Transnnrration Environmental Health Public Services Energy/ Historic/Cultural Natura( Resources Preservation Airport Environment 10,000 Feet 14,000 Feet B. POLICY-RELATED COMMENTS C. CODE-RELATED COMMENTS . . . • /) ,)~~-ALF~' We have rev;ewed this application w;th particular attention to those areas in which we have expertise and have identified areas of probable impact or areas wher, additional information is needed properly assess this proposal. CITY OF RENTON CURRENT PLANNING DIVISION AFFIDAVIT OF SERVICE BY MAILING On the 2?1h day of October, 2006, I deposited in the mails of the United States, a sealed envelope containing Acceptance Ltr, NOA, Environmental Checklist, & PMT's documents. This information was sent to: Name Agencies Eric LaBrie Marc Rousso Charles Ratzsch Alice Knight -Trustee for Violet Bliss Estate Surrounding Property Owners (Signature of Sender): Jtiffj .....::k« 4·, , STATE OF WASHINGTON ) ) ss COUNTY OF KING ) Dated: \D I~ t\ c (,,, Reoresentina See Attached Contact Applicant Owner Owner See Attached Notary (Print): f'w:::;,\ .:>fc ,~ Lj nr, 1--ic<;,;.vY>-cq, My appointment expires: c) -\ q, -\ c Project Name: Bremerton Avenue Townhomes Project Number: LUA06-133, PP, SA-A, CU-A, ECF template -affidavit of service by mailing Dept. of Ecology • Environmental Review Section PO Box47703 Olvmoia, WA 98504-7703 AGENCY {DOE) LETTER MAILING (ERG DETERMINATIONS) WDFW -Stewart Reinbold• Muckleshoot Indian Tribe Fisheries Dept. c/o Department of Ecology Attn: Karen Walter or SEPA Reviewer 3190 160th Ave SE 39015 -172"' Avenue SE Bellevue, WA 98008 Auburn, WA 98092 . WSDOT Northwest Region • Duwamish Tribal Office• Muckleshoot Cultural Resources Program • Attn: Ramin Pazooki 4717 W Marginal Way SW Attn: Ms Melissa Calvert King Area Dev. Serv., MS-240 Seattle, WA 98106-1514 39015 172°' Avenue SE PO Box 330310 Auburn, WA 98092-9763 Seattle, WA 98133-9710 US Army Corp. of Engineers• KC Wastewater Treatment Division• Office of Archaeology & Historic Seattle District Office Environmental Planning Supervisor Preservation* Attn: SEPA Reviewer Ms. Shirley Marroquin Attn: Stephanie Kramer PO Box C-3755 201 S. Jackson ST. MS KSC-NR-050 PO Box 48343 Seattle, WA 98124 Seattle, WA 98104-3855 Olvmoia, WA 98504-8343 Jamey Taylor• Depart. of Natural Resources PO Box 47015 Olvmoia, WA 98504-7015 KC Dev. & Environmental Serv. City of Newcastle City of Kent ' Attn: SEPA Section Attn: Mr. Micheal E. Nicholson Attn: Mr. Fred Satterstrom, AICP 900 Oakesdale Ave. SW Director of Community Development Acting Community Dev. Director Renton, WA 98055-1219 13020 SE 72°' Place 220 Fourth Avenue South Newcastle, WA 98059 Kent, WA 98032-5895 - Metro Transit Puget Sound Energy City of Tukwila Senior Environmental Planner Municipal Liason Manager Steve Lancaster, Responsible Official Gary Kriedt Joe Jainga 6300 Southcenter Blvd. 201 South Jackson Street KSC-TR-0431 PO Box 90868, MS: XRD-01W Tukwila, WA 98188 Seattle, WA 98104-3856 Bellevue. WA 98009-0868 Seattle Public Utilities Real Estate Services Title Examiner 700 Fifth Avenue, Suite 4900 PO Box 34018 Seattle, WA 98124-4018 Note: If the Notice of Application states that it is an "Optional DNS", the marked agencies and cities will need to be sent a copy of the checklist, PMT's, and the notice of application. • Also note, do not mail Jamey Taylor any of the notices she gets hers from the web. Only send her the ERC Determination paperwork. template -affidavit of service by mailing 152305903600 BALES LIMITED PARTNERSHIP PO BOX 3015 RENTON WA 98056 518210004108 DENTON JAMES M 4455 TOLT RIVER RD NE CARNATION WA 98015 421960029005 LEGGIO FRANK J III +AMY SCHR 262 CHELAN CT NE RENTON WA 98059 152305919200 PIPPIN CORTESS D 310 BREM ER TON AVE NE RENTON WA 98059 421960028007 TRINH DAN+QUEENIE TAN 268 CHELAN CT NE RENTON WA 98059 421960026001 WONG BEN+SOPHIE LY 4612 NE 2N D CT RENTON WA 98059 152305903501 BLISS VIOLET F 330 BREMERTON AVE NE RENTON WA 98059 152305909409 HILLCREST SQUARE L L C 10430 RENTON-ISSAQUAH RD SE ISSAQUAH WA 98027 421960027009 MCCLUSKEY ANDREW W+LISA ANN 274 CHELAN CT NE RENTON WA 98059 152305919309 RATZSCH CHARLES G 320 BREMERTON AVE NE RENTON WA 98059 205050001002 U S BANK CORPORATE PROPS 2800 E LAKE ST MINNEAPOLIS MN 55406 421960073003 CONNER HOMES CO 846 108TH AVE NE BELLEVUE WA 98004 421960025003 HUYNH PHOUNG V+NGUYEN TRON 4606 NE 2ND CT RENTON WA 98059 421960024006 NGUYEN TU+THAO DO 4600 NE 2ND CT RENTON WA 98059 518210004280 RIDGEVIEW COURT LLC PO BOX 2401 KIRKLAND WA 98083 152305903006 VUE FUE 13004 136TH AVE SE RENTON WA 98059 DATE: October 27, 2006 LAND USE NUMBER: LUAl'.l6-133, PP, SA-A CU-A, ECF PROJECT NAME: Bremerton Avenue Townhomes PROJECT DESCRIPTION; The appOcant is requesbng Preliminary Plat approval. s,te P,an aopraval Conditional Use Perm;t approval and Environmental (SEPA) Review to subdrv1de an existing 78,466 square too: (1 8 ac,e} Sile zoned Commencial Artenal (CA) Into 26 lots for the future development of attached lownhome um;s_ The eroposed lots. would range from a minimum of 1,426 square feet to a maximum ol 3,337 square feet in area Two e~isting res,dences on the project sM are proposed to be removed. Access to the new townhome unil:5 would be prov,Ced v,a a new internal public street system PROJECT LOCATION: 320 & 330 Br9me1100 Avenue NE OPTIONAL_DETERMINATION OF NON-SIGNIFICANCE, MITIGATED fDNS-M): As the Lead Agency tne C,tt or Renton has determined 11'1at S11Jnilicant envoroomenlal impacts are unlikely to result from the proposed prqect Thera!ore as perm,_tted under lhe RCW 43 21C.110 .the City of Ren.ton rs using the OpOonal DNS-M p'.ocess to give no:,ce thal a ONS- M ,s hke:y to be ,ssued Comment r,enods for the proiecl and the proposed DNS-M are integrated into a Single comment period. There will be no comment p&riod follow,ng lhe ,ssuance of the Threshold Determination ot Ncn.S1gmficanca- M1hgated (DNS-M). A 14--0a~ app&al period w,11 /otlow lhe issuance of the DNS-M PERMIT APPLICATION DATE: NOTICE OF COMPLETE APPLICATION: Octotier 17, 2006 October 27. 2006 APPLICANTrPROJECT CONTACT PERSON: Eric LaBrte, ESM Caneultlng Englnaars; Tai: (253183S-6113: Eml: erk:.labrle@ .. mc1vll.t:om Parmltto/Ravlaw Requa,wd: Envlronmanhl (SEPA) R1vlew, Conditional Un Parmlt, S1te Plan approval and Prallmlnary Plat approval Other Permits which may be required: Bulldlng, Flra, and U!lllty Conatn.1ctlon Requaat,d S\udte.: Gaolat:hnlcal Report, Stl'llam AHHsment, Drainage Report, and Traffic Study Location where 1ppllca1lon may be Nlvlawad; Plannln9/8ulldlng/Publlc Work1 Departmant, Devalopment Servkes Dlvl,lon, Sixth Floor Ran tan City Hall, 1055 South Grady Way, Renlon, WA 98055 PUBLIC HEARING: Pubhc hMciog is tental'Yl''Y :;rbftd11led foe Dacember 19 2006 before the Renton Haarmg E:<amioer in Benton C211ncH Chambers. H&arlnga begin at s:cio A~1---;:;;:;- lhe 7th floor of the new Renton Coty Hall located at 1055 South Grady Wa·1 CONSISTENCY OVERVIEW: Zoning/land Un: Environmental Dooument& that Evaluate the Proposed Proj..::t: ~velopment Regulatlong Used For Project MIUgatlon: The sobjeci site IS designatlld Commercial Corridor (CC) on 1he City of Renton Comprehensive Land Use Map and Commercial Arte~al (CAf on the City's Zoning Map Envsronmental (SEPAi Checkist The proJect w.11 be subject to the C•t'ls SEPA ordinar,ce. RMC 4 . .:..03:i De,elopment Guidehnos and Regulatrons, RMC 4--6-030 Drainage Slandords and other applicable codes and ragulat>ons as appropriate roposed Milig,tlon M,aeurn: Tho lollowi~g Mit,gali<,n Measures will likel~ be imposed on the proposed project Thasa recommended Mitigation Measuras address project impacts not co,ered by ex,st,ng codes and regulations as cited abo~e Th,; app/1,;;a111 will tie required to pay Iha appropnele T ra11sporMron Mit,gation Fae: The applicant wlll ba requ/rw to pay ttm appropria/9 Fir9 Mitigation Fee: The applicant wll! ba requirod to pay Ille appropriate Perks Mitigation Fae; Erosion control shell comp!y with the Oapartm,,mt of Ecology ,m,siori and sOOim&nlallon control srandards as outlinad in the Departman/ of Ecology Stormwetar Manageme11t Manual; and Project const,uct1on .sl!a/1 comply with the racommendatrons found in th,; .submitted geotachnr,;;11/ report, and The projectwi!I 09 requif9d ro comply with the 2005 King County Surtace·weter Design Manual :omments on the •bov• application must b• tubmltt•d In writing to JIii Ding, Senior Planner, Development ;ervit:in Division, 1055 South Grady Way, R•nton, WA 98055, by 5:00 PM on Novemb.r 10,200$. This matt.r ls ,lso tanlatlvely scheduled for a public hearing on Decemb6r 18, 2006, at 9:00 AM, CoYncil Chambers, Seven1h Floor, lenton c,ty Hall, 1055 Sooth Grady Way, Renton If you are interested 1n attend•ng the Mearing, please contact the le.,.loPff"o'nt 5eMces Division to ensure that the hearing has not b_een rescheduled at_(425) 430-7282 If comments :annot be submitted in wntJng by the date ind~t:ed at,o,,e, you may still appear at the heanng and present your comments ,n the proposal ti91ore the Hearing E:<aminar If you have questions about this proposal, or wish to be made a party o! acord and receive additional information by mail, please contact the proJect manager. Anyone wllo submits wntten :ocnmenta will automa~lly become a p¥ty of record and will be notified of any decision on 1h1s pro1ect '.:ONTACT PERSON: Jill K. Ding, Senior Planner; Tel (425) 430-7219; Eml: jding@ci.renton.wa.us 1; you would hke to be made a party of record 10 rece1~e further information on this proposed project complete this form and return to: City of Renton, Development Planning, 1055 So. Grady Way, Renton, WA 98055. Name/File No· Bremerton A~enue Townhomes/LUA06-133, PP, SA-A, CU-A, ECF NAME MAIUNG ADDRESS TELEPHONE NO. CERTIFICATION I, ¥71::1 fzr::,s.gg_ , hereby certify that 5 copies of the above document were posted by me in 3 conspicuous places or nearby the described property on DATE: 10-2::;.ob SIGNED: w~ ,1>'""~11111 11 :;, ,, ~NN i.,,.:..•.1 11 1 ..... .-:.. \.-·"' \•\~\:~~..('-,,, ATTEST: Subscnbed and sworn betore me, a Notary Public, 111 and for the State of Washington residing m ~ ~ r;..J:-~. ,· iON .E'~~,~~~ :: ... .:~• ,)1,.0:,.J,>, :.P\_"J.~ , "" ;~ ,:i.'' J.. ~~ ~ ~ ~ 1_Y"',, . ~ u,~ ~ t'cu.,iu ,onlhe yl dayof LI \0/,,,-1 e :; NOTARYPUBLICSIG~A .·. E:~, ,c, E:;:::: "/; >.°',1, ~us\...:~ $".:J....o: ,, --9· 1'fii'~ ~ 19, ·~ ... ~ 0 :::- ,,, /'~ hn1"1\"''~~,~ ~ 111 1 OF w,.._s ,.,,, '"'"\\"''' "\.~y 0 :~~ ~< NOTICE OF APPLICATION AND PROPOSED DETERMINATION OF NON-SIGNIFICANCE-MITIGATED (DNS-M) DATE: LAND USE NUMBER: PROJECT NAME: October 27, 2006 LUA06-133, PP, SA-A, CU-A, ECF Bremerton Avenue Townhomes PROJECT DESCRIPTION: · The applicant is requesting Preliminary Plat approval, Site Plan approval, Conditional Use Permit approval, and Environmental (SEPA} Review to subdivide an existing 78,466 square foot (1.8 acre) site zoned Commericial Arterial (CA) into 26 lots for the future development of attached townhome units. The proposed lots would range from a minimum of 1,426 square feet to a maximum of 3,337 square feet in area. Two existing residences on the project site are proposed to be removed. Access to the new townhome units would be provided via a new internal public street system. PROJECT LOCATION: 320 & 330 Bremerton Avenue NE OPTIONAL DETERMINATION OF NON-SIGNIFICANCE, MITIGATED (DNS-M): As the Lead Agency, the City of Renton has determined that significant environmental impacts are unlikely to result from the proposed project Therefore, as permitted under the RCW 43.21C.110, the City of Renton is using the Optional DNS-M process to give notice that a DNS- M is likely to be issued. Comment periods for the project and the proposed DNS-M are integrated into a single comment period. There will be no comment period following the issuance of the Threshold Determination of Non-Significance- Mitigated (DNS-M). A 14-day appeal period will follow the issuance of the DNS-M. PERMIT APPLICATION DATE: NOTICE OF COMPLETE APPLICATION: October 17, 2006 October 27, 2006 APPLICANT/PROJECT CONTACT PERSON: Eric LaBrie, ESM Consulting Engineers; Tel: (253) 838-6113; Emf: eric.labrie@esmcivil.com PermitsfReview Requested: Environmental (SEPA) Review, Conditional Use Permit, Site Plan approval and Preliminary Plat approval Other Permits which may be required: Building, Fire, and Utility Construction Requested Studies: Location where application may be reviewed: PUBLIC HEARING: CONSISTENCY OVERVIEW: Zoning/Land Use: Environmental Documents that Evaluate the Proposed Project: Development Regulations Used For Project Mitigation: Geotechnical Report, Stream Assessment, Drainage Report, and Traffic Study Planning/Building/Public Works Department, Development Services Division, Sixth Floor Renton City Hall, 1055 South Grady Way, Renton, WA 98055 Public hearing is tentatively scheduled for December 19, 2006 before the Renton Hearing Examiner in Renton Council Chambers. Hearings begin at 9:00 AM on the 7th floor of the new Renton City Hall located at 1055 South Grady Way. The subject site is designated Commercial Corridor (CC) on the City of Renton Comprehensive Land Use Map and Commercial Arterial (CA) on the City's Zoning Map. Environmental (SEPA) Checklist The project will be subject to the City's SEPA ordinance, RMC 4-4-030 Development Guidelines and Regulations, RMC 4-6-030 Drainage Standards and other applicable codes and regulations as appropriate. Proposed Mitigation Measures: The following Mitigation Measures will likely be imposed on the proposed project. These recommended Mitigation Measures address project impacts not covered by existing codes and regulations as cited above. The applicant will be required to pay the appropriate Transportation Miugation Fee; The appUcant will be required to pay the appropriate Fire Mitigation Fee; The applicant will be required to pay the appropriate Parks Mitigation Fee; Erosion control shall comply with the Department of Ecology erosion and sedimentation control standards as outlined in the Department of Ecology Stormwater Management Manual; and Project construction shall comply with the recommendations found in the submitted geotechnical report: and The project-Will be required to comply with the 2005 King County Surface·water Design Manual. Comments on the above application must be submitted in writing to JIii Ding, Senior Planner, Development Services Division, 1055 South Grady Way, Renton, WA 98055, by 5:00 PM on November 10, 2006. This matter is also tentatively scheduled for a public hearing on December 19, 2006, at 9:00 AM, Council Chambers, Seventh Floor, Renton City Hall, 1055 South Grady Way, Renton. If you are interested in attending the hearing, please contact the Development Services Division to ensure that the hearing has not been rescheduled at (425) 430-7282. If comments cannot be submitted in writing by the date indicated above, you may still appear at the hearing and present your comments on the proposal before the Hearing Examiner. If you have questions about this proposal, or wish to be made a party of record and receive additional information by mail, please contact the project manager. Anyone who submits written comments will automatically become a party of record and will be notified of any decision on this project. CONTACT PERSON: Jill K. Ding, Senior Planner; Tel (425) 430-7219; Eml: jding@ci.renton.wa.us If you would like to be made a party of record to receive further information on this proposed project, complete this form and return to: City of Renton, Development Planning, 1055 So. Grady Way, Renton, WA 98055. Name/File No.: Bremerton Avenue Townhomes/LUA06-133, PP, SA-A, CU-A, ECF NAME: MAILING ADDRESS: TELEPHONE NO.: o"~JY ~~ ·~ + ~-~ KathyKeolker,Mayor Planning/Building/Public Works Department Gregg Zimmerman P.E., Administrator a,Ni'\'O October 27, 2006 Eric LaBrie ESM Consulting Engineers 33915 1'1 Way S #200 Federal Way, WA 98003 Subject: Bremerton Avenue Townhomes LUA06-133, PP, SA-A. CU-A, ECF Dear Mr. LaBrie: The Development Planning Section of the City of Renton has determined that the subject application is complete according to submittal requirements and, therefore, is accepted for review. It is tentatively scheduled for consideration by the Environmental Review Committee on November 20, 2006. Prior to that review, you will be notified if any additional information is required to continue processing your application. In addition, this matter is tentatively scheduled for a Public Hearing on December 19, 2006 at 9:00 AM, Council Chambers, Seventh Floor, Renton City Hall, 1055 South Grady Way, Renton. The applicant or representative(s) of the applicant are required to be present at the public hearing. A copy of the staff report will be mailed to you prior to the scheduled hearing. Please contact me at (425) 430-7219 if you have any questions. Sincerely, (pl 1{J2_- Senior Planner U v7ii~-~,:_~ing · cc: Charles Ratzsch, Alice Knight -Trustee for Violet Bliss Estate/ Owners Marc Rousso/ Applicant -------l-0-55_S_o_u_th_G_r-ad_y_W-ay---R-e_n_to-n,-W-a-s-ht-.n-gt-on-9-80_5_5 _______ ~ ~ This paper contains 51J% recycled material, 30% DOStconsumer AHEAD O.F THE CURVE "~y 0 o~,. ~ ·~. ~ -~ Kathy Keolker, Mayor &>N,rO October 27. 2006 Michael Fortson Department of Transportation Renton School District 1220 N 4th Street Renton, WA 98055 Subject: Bremerton Avenue Townhomes LUA06-133, PP, SA-A, CU-A, ECF CIT~OF RENTON Planning/Building/Public Works Department Gregg Zimmerman P.E., Administrator The City of Renton Development Services Division has received an application for a 26-lot townhouse subdivision located at 320 & 330 Bremerton Avenue NE. Please see the enclosed Notice of Application for further details. In order to process this application, the Development Services Division needs to know which Renton schools would be attended by children living in residences at the location indicated above. Please fill in the appropriate schools on the list below and return this letter to my attention, Development Services Division, City of Renton, 1055 South Grady Way, Renton, Washington 98055 by November 10, 2006. Elementary School:--------------------------- Middle School: ________________________ .:.._ __ High School: ---------------------------- Will the schools you have indicated be able to handle the impact of the additional students estimated to come from the proposed development? Yes No __ _ Any Comments: ___________________________ _ Thank you for providing this important information. If you have any questions regarding this project, please contact me at (425) 430-7219. Sincerely, c}JJ 1{ 221}-. v~i~-~~ Ding Senior Planner , Encl. -------I-0-55_S_o_u_th_G_r_ad_y_W-ay---R-e-nt-o-n,-W-a-,-h,-.n-gt-on_9_80_5_5 _______ ~ @) This paper contains 50% recycled material. 30% post consumer AHEAD OF THE C:URVE TO: DRISCOLL ARCHITECTS .... COMMERCIAL ARTERIAL CRITERIA JUSTIFICATION Whom it May Concern City of Renton Development Services Division 1055 South Grady Way Renton, WA 98055 FROM: Gregory D. Blount, DAps DATE: 25 October 2006 PROJECT LOCATION: 330 Bremerton Ave NE Renton, WA 98059 PROJECT NAME: Bremerton Avenue Townhouses Conditional Use Permit Justification Marc Rousso RE: COPY: Please consider the following written justification in favor of the application. Herein we address the Special Decision Criteria for Stand-Alone Residential Uses in the Northeast 4th Business District criteria. This format follows the criteria listed under Item "K" in the packet. 1. Our site is more than 150' from the south edge of NE 41h. This site has no frontage on NE 4th and has no frontage on Duvall Avenue in the NE 4th Street Business District. Therefore this site qualifies for stand-alone residential use. 2. There is a mix of commercial, service and residential uses immediately adjacent to our site and within 150' of our site, thus: North-Commercial (Bank), West-Residential, South-Residential and East-Commercial. 3. There is no street frontage on NE 4th and therefore no direct access to NE 4th. This makes it economically infeasible to construct any commercial building except perhaps an automotive shop which doesn't require street frontage. 4. To augment the commercial arterial zone, we have provided a pedestrian connection from the south, throu~h our site to the Bremerton Avenue sidewalk, which extends north to the Commercial Arterial NE 4 h to the north of our site. Our project provides twenty-six, close-in, new, owner- occupied townhouse homes that will be purchased and occupied by a service users and product consumers. The use proposed is consistent with what is, in our opinion, the best use of the property. 5. We provide a connection from lower density to higher density with our walkway. Townhouse residential development, with a residential architectural character precisely transitions between residential and commercial use and scale. It is larger and more robust than single-family, and provides more articulation and open-space than commercial. 6. The project is subject to review and approval by City of Renton Planning/Building/Public Works Department and is required to meet all Development Standards from RMC 4-3-040F. We believe the project, as submitted, already meets these standards. The pedestrian connection provided similarly meets standards, and is subject to review and approval. Sincerely, DRISCOLL ARCHITECTS, PS Greg Blount, Architect Vice President X. \2005direct\0516\Arleria/Crilen·aJustification DOC A Professional Services Corporation 115 Bell St. Seattle, WA 98121 (206)441-7705 Fax: (206)441-5373 E-Mail: daps@drisarch.com TO: DRISCOLL ARCHITECTS .... CONDITIONAL USE PERMIT JUSTIFICATION Whom it May Concern City of Renton Development Services Division 1055 South Grady Way Renton, WA 98055 FROM: Gregory D. Blount, DAps DATE: 12 October 2006 PROJECT LOCATION: 330 Bremerton Ave NE Renton, WA 98059 PROJECT NAME: Bremerton Avenue Townhouses Conditional Use Permit Justification Marc Rousso RE: COPY: Hugh Schaeffer; DAps Please consider the following reasons in favor of the application, which address the following criteria. Also please consider the documentation submitted with the Conditional Use Permit Application. Our format follows the analysis criteria listed in the packet. Comprehensive Plan: • Comp Plan Designation is "Commercial Corridor." Commercial Arterial zoned areas should include an opportunity for residential uses (Policy LU-338). Zoning is CA "commercial arterial." Parking is (per LU-363) in parking structures (attached garages). • This area is characterized by new and existinj housing developments and single-family off 4'" and mostly commercial development along 4 itself. The property in question (site) does not abut NE 4'". There are other new housing developments in the immediate vicinity and a similar townhouse development nearby north of 4~ (Cobblestone Court). • This corridor is within the urban growth area boundaries and is served by transit along 4'". • City review of SEPA requirements, re traffic, tree removal, noise etc. will assess impact of the proposed development and mitigate these impacts if necessary. • The project will comply with all zoning standards except for front yard setback (for the new porch structures) along the new proposed public street and alley. • Fire Department access via looped roadway/alley system. There is one short dead-end well under 150' in length. • Guest parking is provided on the new public street located on the site and in new driveways. • Stormwater detention is located in underground vaults: See Civil drawings. Community Need: • Nearby, new housing and commercial development have recently been completed and are, by all accounts, successful ventures for their respective speculative developers. This for-sale project is targeted to middle-income purchasers. • Mixed-use neighborhood, close-in • A primary marketing feature will be the price for this new, owned housing opportunity. • The developer has conducted a market analysis and has identified a demand for this product. Effect on Adjacent Properties; • The property sits at a grade below the commercial property to the north, as a result of a slope toward the south from the bank parking lot. The commercial building itself is located north of a A Professional Services Corporation 115 Bell St. Seattle, WA 98121 (206)441-7705 Fax: (206)441-5373 E-Mail: daps@drisarch.com Conditional Use Permit Justification Bremerton Avenue Townhouses 12 October 2006 parking lot adjacent to this site. These facts. in addition to the location of the new public alley along the north portion of our site separate and mitigate the impact of the proposed development to the north. • There is a new commercial development to the east. The residential scale of our development and separation between the duplex and triplex structures along our east property line, in combination with the ten-foot rear yard setback along our east property line reduce the effect on the adjacent property to the east. • The new single-family development to the west of our property is across Bremerton Avenue and is a similar and compatible residential scale. We do not anticipate any aesthetic or significant impact that would not be addressed by SEPA. • The R-8 zoned property to the south is likely to be developed in the future and is currently in residential use. There will be a new pedestrian connection from the properties to the south. • Bremerton Avenue to the west separates this project from the residential development and vacant properties to the west. Bremerton Avenue is largely improved already and accesses several new residential developments to the south and west. SEPA impacts will be mitigated as required during the course of plan review. • There are only 26 residential units. Other Items: • Compatibility o Residential scale, traditional residential architectural detailing. • Parking o Two garage stalls per unit. Some units have driveway parking for guests. Two off-street guest stalls are provided. Numerous public parking stalls (for guests) will be available on the public street. • Traffic o See traffic report. • Noise, Glare o Residential use. Construction noise will be limited to construction hours only and will cease with completion of construction. Architectural exterior lighting will be shielded and street lighting will be to City standards. • Landscaping o See Landscape Plans • Accessory Uses o None; N/A • Conversion o NIA • Public Improvements o New street and alley to be built to City standards. Looped access provided. • Lot Coverage o See Civil Plans • Yards o All yards comply with the zoning code except front yards on new public streets and roads have residential covered entry porches located in required front yards. • Height o Maximum building height is approximately 36 feet; see elevation drawings. Sincerely, DRISCOLL ARCHITECTS, PS Greg Blount, Architect Vice President • October 23, 2006 Eric LaBrie ESM Consulting Engineers 33915 I" Way S, Suite 200 Federal Way, WA 98003 CIT~ -OF RENTON Planning/Building/Public Works Department Gregg Zimmerman P.E., Administrator RE: Notice oflncomplete Application Bremerton Townhomes (File No. LUA06-133, PP, SA-A, CU-A, ECF) Dear Mr. LaBrie: After an initial review of your submittal for the Bremerton Townhomes project, additional information is required before review of the project can begin. Please submit 12 copies of the following: I. A written justification for the Conditional Use Permit addressing the attached criteria used in analyzing your application; and 2. A written justification for the approval of stand alone residential on a Commercial Arterial (CA) zoned parcel addressing the criteria out lined in RMC 4-9-030K (attached). Stand alone residential shall only be permitted when all of the criteria outlined in RMC 4-9-030K are met. Once the above requested items are received review of your application will begin. If you have any questions, feel free to contact me at (425) 430-7219. Sincerely, Lj)J 1( :J2u· ~ !_ill K. Ding Semor Planner cc: Owners Applicant Enclosures -------10_5_5 _So_u_th_Gr_ad_y_W_a_y_--R-en-to_n_, -W-as-h-in-gt-on-9-80_5_5 ______ ~ @ This paper contains 50% recycled material, 30% post consumer AHEAD OF THE CURVE , 7. D Conditional. Use Permit Justification: Please provide 12 copies of a written statement setting forth the reasons in favor of the application and addressing the following criteria used by the reviewing official in analyzing the application: A Comprehensive Plan: The proposed use shall be compatible with the general purpose, goals, objectives and standards of the comprehensive plan, the zoning ordinance and any other plan, program, map or ordinance of the City of Renton. B. Community Need: There shall be a community need for the proposed use at the proposed location. In the determination of community need, the reviewing official shall consider the following factors among all other relevant infonmation: 1. The proposed location shall not result in either the detrimental over- concentration of a particular use within the City or within the immediate area of the proposed use. 2. The proposed location is suited for the proposed use. C. Effect on Adjacent Properties: The proposed use at the proposed location shall not result in substantial or undue adverse effects on adjacent property. In addition tt,e reviewing official shall also consider the following items when analyzing the application.' • Compatibility: The proposed use shall be compatible with the residential scale and character of the neighborhood. • Parking: Parking under the building structure should be encouraged. Lot coverage may be increased to as much as 75% of the lot coverage requirement of the zone in which the proposed use is located if all parking is provided underground or within the structure. • Traffic: Traffic and circulation patterns of vehicles and pedestrians relating to the proposed use and surrounding area shall be reviewed for potential effects on, and to ensure safe movement in, the surrounding area. • Noise, Glare: Potential noise, light and glare impacts shall be evaluated based on the location of the proposed use on the lot and the location of on-site parking areas, outdoor recreational areas and refuse storage areas. • Landscaping: Landscaping shall be provided in all areas not occupied by buildings or paving. The Hearing Examiner may require additional landscaping to buffer adjacent properties from potentially adverse effects of the proposed use. • Accessory Uses: Accessory uses to conditional uses such as day schools, auditoriums used for social and sport activities, health centers, convents, preschool facilities, convalescent homes and others of a similar nature shall be considered to be separate uses and shall be subject to the provisions of the use district in which they are located. • Conversion: No existing building or structure shall be converted to a conditional use unless such building or structure complies, or is brought into compliance, with the development standards. • Public Improvements: The proposed use and location shall be adequately served by and not impose an undue burden on any public improvements, facilities, utilities and services. Approval of a conditional use permit may be conditioned upon the provision and/or guarantee by the applicant of necessary public improvements, facilities, utilities and/or services. • Lot Coverage: Lot coverage in residential districts (SF and MR) shall not exceed fifty percent of the lot coverage of the zone in which the proposed use is to be located. Lot coverage in all other zones shall conform to the requirements of the zone in which the proposed use is to be located • Yards: Yards shall conform to the requirements of the zone in which the proposed use is to be located. Additions to the structure shall not be allowed in any required yard • Height: Building and structure heights shall conform to the requirements of the zone in which the proposed use is to be located. Spires, belltowers, public utility antennas or similar structures may exceed the height requirement upon approval of a variance. PW/DevServ/Forms/Planning/CU 3 09105 4-9-030J 3. Adequate buffering is provided from abutting and adjacent uses. 4. Adequate security is demonstrated by the applicant. 5. Public input is provided during the siting process. (Ord. 4982, 12-9-2002) J. SPECIAL DECISION CRITERIA FOR WIRELESS COMMUNICATION FACILITIES IN LIEU OF STANDARD CRITERIA: The governing authority shall consider the follow- ing factors in determining whether to issue a con- ditional use permit, although the governing authority may waive or reduce the burden on the applicant of one or more of these criteria if the governing authority, concludes that the goals of RMC 4-4-140, Wireless Communication Facili- ties, are better served thereby. (Ord. 4689, 11-24-1997) 1. Height of the proposed tower. 2. Proximity of the tower to residential struc- tures and residential district boundaries. 3. Nature of uses on adjacent and nearby properties. 4. Surrounding topography. 5. Surrounding tree coverage and foliage. 6. Design of the tower, with particular refer- ence to design characteristics that have the effect of reducing or eliminating visual obtru- siveness. 7. Proposed ingress and egress. 8. Potential noise, light and glare impacts. 9. Availability of suitable existing towers and other structures. 10. Compatibility with the general purpose, goals, objectives and standards of the Com- prehensive Plan, the Zoning Ordinance and any other plan, program, map or ordinance of the City. (Ord. 4689, 11-24-1997) * K. SPECIAL DECISION CRITERIA FOR STAND ALONE RESIDENTIAL USES IN THE NE 4TH, SUNSET, OR PUGET BUSINESS DISTRICTS: 1. Stand alone residential use may not be located within one hundred fifty feet (150') of an adjacent or abutting arterial street. This in- cludes Sunset Boulevard, Duvall Avenue, An- acortes Avenue, or Union Avenue in the Sunset Business District; NE 4th Street, Union Avenue, or Duvall Avenue in the NE 4th Street Business District; and Puget Drive or South Benson Road in the Puget Drive Business District, as shown on the Business District Maps in RMC 4-3-040. 2. A mix of commercial, service, and resi- dential uses exist within a one hundred fifty foot (150') radius of the proposed residential use. 3. Commercial use of the property is not feasible for reasons including, but not limited to: lack of commercial frontage, lack of ac- cess, critical areas and/or critical area buff- ers, or property configuration. 4. Residential use will augment the primary purpose of the commercial arterial zone by adding a pedestrian oriented land use that provides a physical connection between resi- dential and commercial uses. 5. The use provides a transition between commercial and lower density R-10 and R-8 zoned areas and provides a visual, pedes- trian, and vehicular connection from the resi- dential zoned areas to the Commercial Arterial zoned areas. 6. Development standards from RMC 4-3-040F are met unless the applicant opts for a planned urban development, subject to RMC 4-9-150. Pedestrian connection stan- dards from this section must be met without modification. (Ord. 5191, 12-12-2005) L. DECISION AND CONDITIONS: The governing authority may grant, with or with- out conditions, or deny the requested conditional use permit. The Zoning Administrator or Hearing Examiner shall have authority to grant the condi- tional use permit upon making a determination, in writing, that the use is consistent with subsection (Revised 3/06) 9-4 J ;+ .---.,_) •) I \...,· ··-.l City of Renton LAND USE PERMIT MASTER APPLICATION PROPERTY OWNER(S) PROJECT INFORMATION NAME: Charles Ratzsch PROJECT OR DEVELOPMENT NAME: Bremerton Avem Townhomes ADDRESS: 320 Bremerton Ave. NE PROJECT/ADDRESS(S)/LOCATION AND ZIP CODE: CITY: Renton ZIP:98059 330 Bremerton Ave. NE, Renton, WA 98059 TELEPHONE NUMBER: KING COUNTY ASSESSOR'S ACCOUNT NUMBER(S): APPLICANT (if other than owner) 152305-9193 NAME: Marc Rousso EXISTING LAND USE(S): Single family residential and vacant land COMPANY (if applicable): Seattle Redevleopment. PROPOSED LAND USE(S): Single family residential LLC ADDRESS: PO Box 2566 EXISTING COMPREHENSIVE PLAN MAP DESIGNATION: Commercial Corridor CITY: Renton ZIP:98056 PROPOSED COMPREHENSIVE PLAN MAP DESIGNATION (if applicable): Commercial Corridor TELEPHONE NUMBER 206-948-8899 EXISTING ZONING: CA CONT ACT PERSON PROPOSED ZONING (if applicable): CA NAME: Eric LaBrie SITE AREA (in square feet): 361,502 sf SQUARE FOOTAGE OF PUBLIC ROADWAYS TO BE COMPANY (if applicable): ESM Consulting Engineers DEDICATED: 14,535 sf SQUARE FOOTAGE OF PRIVATE ACCESS EASEMENTS ADDRESS: 33915 1st Way S. Ste #200 7,439 sf PROPOSED RESIDENTIAL DENSITY IN UNITS PER NET CITY: Federal Way ZIP:98003 ACRE (if applicable): 20.0 units/acre NUMBER OF PROPOSED LOTS (if applicable): 26 TELEPHONE NUMBER AND E-MAIL ADDRESS: 253-838- 6113 eric.labrie@esmcivil.com NUMBER OF NEW DWELLING UNITS (if applicable): 26 Q·wcb/p\v/dcvscrv/forms/planning/masterapp doc 09/28/06 F IJECT INFORMATION (con 1ed) NUMBER OF EXISTING DWELLING UNITS (if applicable): 2 PROJECT VALUE: SQUARE FOOTAGE OF PROPOSED RESIDENTIAL BUILDINGS (if applicable): Approximately 2,500 sf IS THE SITE LOCATED IN ANY TYPE OF ENVIRONMENTALLY CRITICAL AREA, PLEASE INCLUDE SQUARE FOOTAGE (if applicable): SQUARE FOOTAGE OF EXISTING RESIDENTIAL BUILDINGS TO REMAIN (if applicable): N/A SQUARE FOOTAGE OF PROPOSED NON-RESIDENTIAL BUILDINGS (if applicable): N/A SQUARE FOOTAGE OF EXISTING NON-RESIDENTIAL BUILDINGS TO REMAIN (if applicable): NIA NET FLOOR AREA OF NON-RESIDENTIAL BUILDINGS (if applicable):NIA NUMBER OF EMPLOYEES TO BE EMPLOYED BY THE NEW PROJECT (if applicable): N/A O AQUIFER PROTECTION AREA ONE O AQUIFER PROTECTION AREA TWO o FLOOD HAZARD AREA o GEOLOGIC HAZARD o HABITAT CONSERVATION o SHORELINE STREAMS AND LAKES o WETLANDS LEGAL DESCRIPTION OF PROPERTY ___ sq.ft. ___ sq.ft. sq. ft. sq. ft. sq. ft. (Attach leaal descriotion on seoarate sheet with the followina information included} SITUATE IN THE NW QUARTER OF SECTION 1.§__, TOWNSHIP 23 , RANGE--2_, IN THE CITY OF RENTON, KING COUNTY, WASHINGTON. TYPE OF APPLICATION & FEES List all land use applications being applied for. 1. Preliminary Plat 2. SEPA 3. Conditional Use Permit 4. Staff will calculate applicable fees and postage: $ ___ _ AFFIDAVIT OF OWNERSHIP I, (Print Name/s) L 1tA:B LL·· z {_~ BA [Z. ·1 ( ,-, , declare that I am (please check one) /~he current owner of the property involved in this application or __ the authorized representative to act for a corporation (please attach proof of authorization) and that the foregoing statements and answers herein contained and the information herewith are in all respects true and correct to the best of my knowledge an_d_beli~f. I certify that I know or have satisfactory evidence tp,at., / £··1 P?/ l /j (. 6:_ /~;~,. ~'-:._.,,.. /"z·, __ , ..... .:,,·"/7,,,:··/_.;.·.::._:·-'",:::"::t'. :· -t-----'~~. -signed this instrument and acknowledged it to beei£~her/their free and voluntary act for the "i: -,,.-vU--/-, , uses and purposes mentioned in the instrument. ' ·-. (,/ (Signature of Owner/Representative) . \. Notary Public in and Notary (Print) ,, )// i .l ,(,.rz) r My appointment expires:__:____c_-,--..:•'-. _ _:_ __ _ Q: web/pw / devscrv/form s/pl ann ing/mastcrapp. doc 2 09/26/06 LEGAL DESCRIPTION Lots 2 and 3, King County Short Plat Number 675015, recorded under recording number 7509050645, in King County, Washington. City of Renton LAND USE PERMIT MASTER APPLICATION PROPERTY OWNER(S) PROJECT INFORMATION NAME: Alice Knight, successor trustee for PROJECT OR DEVELOPMENT NAME: Bremerton Avenue Violet Bliss Estate Townhomes ADDRESS: 330 Bremerton Ave. NE PROJECT/ADDRESS(S)/LOCATION AND ZIP CODE: CITY: Renton ZIP:98059 330 Bremerton Ave. NE, Renton, WA 98059 TELEPHONE NUMBER: KING COUNTY ASSESSOR'S ACCOUNT NUMBER(S): 152305-9035 APPLICANT (if other than owner) EXISTING LAND USE(S): Single family residential and vacant NAME: Marc Rousso land COMPANY (if applicable): Seattle Redevleopment, PROPOSED LAND USE(S): Single family residential LLC EXISTING COMPREHENSIVE PLAN MAP DESIGNATION: ADDRESS: PO Box 2566 Commercial Corridor CITY: Renton ZIP:98056 PROPOSED COMPREHENSIVE PLAN MAP DESIGNATION (if applicable): Commercial Corridor TELEPHONE NUMBER 206-948-8899 EXISTING ZONING: CA CONTACT PERSON PROPOSED ZONING (if applicable): CA NAME: Eric LaBrie SITE AREA (in square feet): 361,502 sf SQUARE FOOTAGE OF PUBLIC ROADWAYS TO BE COMPANY (if applicable): ESM Consulting Engineers DEDICATED: 14,535 sf SQUARE FOOTAGE OF PRIVATE ACCESS EASEMENTS: ADDRESS: 33915 1st Way S. Ste #200 7,439 sf PROPOSED RESIDENTIAL DENSITY IN UNITS PER NET ACRE (if applicable): 20.0 units/acre CITY: Federal Way ZIP:98003 NUMBER OF PROPOSED LOTS (if applicable): 26 TELEPHONE NUMBER AND E-MAIL ADDRESS: 253-838- 6113 eric.labrie@esmcivil.com NUMBER OF NEW DWELLING UNITS (if applicable): 26 Q. web/pw / dcvscrv /forms/pl anning/masterapp. doc 09/28/06 JECT INFOR NUMBER OF EXISTING DWELLING UNITS (if applicable): 2 MATION (con PROJECT VALUE: 1ed) SQUARE FOOTAGE OF PROPOSED RESIDENTIAL BUILDINGS (if applicable): Approximately 2,500 sf SQUARE FOOTAGE OF EXISTING RESIDENTIAL IS THE SITE LOCATED IN ANY TYPE OF ENVIRONMENTALLY CRITICAL AREA, PLEASE INCLUDE SQUARE FOOTAGE (if applicable): BUILDINGS TO REMAIN (if applicable): N/A SQUARE FOOTAGE OF PROPOSED NON-RESIDENTIAL BUILDINGS (if applicable): N/A SQUARE FOOTAGE OF EXISTING NON-RESIDENTIAL BUILDINGS TO REMAIN (if applicable): N/A NET FLOOR AREA OF NON-RESIDENTIAL BUILDINGS (if applicable):N/A NUMBER OF EMPLOYEES TO BE EMPLOYED BY THE NEW PROJECT (if applicable): N/A o AQUIFER PROTECTION AREA ONE o AQUIFER PROTECTION AREA TWO o FLOOD HAZARD AREA O GEOLOGIC HAZARD o HABITAT CONSERVATION o SHORELINE STREAMS AND LAKES o WETLANDS LEGAL DESCRIPTION OF PROPERTY ___ sq.ft. ___ sq.ft. ___ sq.ft. ___ sq.ft. ___ sq.ft. {Attach leaal description on separate sheet with the followina information included) SITUATE IN THE NW QUARTER OF SECTION 1§__, TOWNSHIP 23 , RANGE_§_, IN THE CITY OF RENTON, KING COUNTY, WASHINGTON. TYPE OF APPLICATION & FEES List all land use applications being applied for: 1. Prelimina[Y Plat 3. Conditional Use Permit 2. SEPA 4. . .. , . . . Staff will calculate applicable fees and postage: $ AFFIDAVIT OF OWNERSHIP · 1 I,,, 1 I, (Print Name/s) --r / 1 • { C v · '\ h, . r.• 11 , declare that I am (please check one) v/~he current owner of the property involved in this application or __ the authorized presentative to act for a corporation (please attach proof of authorization) and that the foregoing statements and answers herein contained and the information herewith are in all respects true and correct to the best of my knowledge and belief. / (Signature of Ow '!Pr/Representati e) (Signature of Owner/Representative) ,; .. .-, ... , Q. web/pw/devserv/forms/planning/masterapp doc I certify that 1 know or have satisfactory evidence that # 1 ,/ 't. -0 ·L,f signed this instrument and acknowledged it to be hi her/their free an voluntary act or the uses and purposes mentioned in the instrument. ; / / Notary rublic in and for the ttat of Washington Notary (Print) /, _;?'/ r •,/Cit, I( I iV My appointment expires:_---'_·,_/_.:_1_11-/_·~--'··-1'--· .:_2'_,·r_· ___ _ I 2 09/26/06 LEGAL DESCRIPTION Lots 2 and 3, King County Short Plat Number 675015, recorded under recording number 7509050645, in King County, Washington. DEVELOPMENT SERVICES DIVISION WAIVER OF SUBMITTAL REQUIREMENTS FOR LAND USE APPLICATIONS LAND USE Jl~F(MIT SUBMITTAL REQ:QJR~"1ENTS; .· ·. . . . Parking, Lot Coverage & Landscaping Analysis, Plan Reductions (PMT~) • < • \ .. _ Plat Certificate or TIiie Report, P!~t Name Reservaj/qri., / ........ _•-> Pre-Application Meeting Summary, ..... Public Works AppiovalJ.;eifer 2 . .. -·:·.. . : ;, . . ·•· ... • .. Rehabilitation Plan , ~~r,~¢riihg Detail:~ >>:.:.:,_/-,-_ . Site Plan 2 AND, 9tre.,/norLakeStudy;:S\~t(c1ard, C \.i . ·•. ·. Stream or Lake Study, Supplemental, Street Profiles 2 Traffic Study 2 tree cutting/Land deilili\giPlan .. < . . \ '' ·_-•. ,• .,.-··,:=·:-· .• -.:-•.•.. ,,-.. ••' .,.:,:.. .-- :· :,_ ,-,: .: Urban Center Design Overlay District Report, Wetlands Mitigation Plan, Final, Weuarids Mitigation ~i~q;):\~liminaryI'. ··· · ·· Wetlands Assessment, Wireless: ·,. ····· .· _ .,.:._:_. ·=···· _.. .... -.. -:-:··:··· . . ·. _ Applicant Agreement Statement 2 AND 3 Inventory of Existing Siles 2 .. 0 , Lease Agreement, Draft 2 AND, Map of Existing Sile Conditions 2 AND 3 Map of View Area 2 .. 0 , Photo simulations 2 ANo> WAIVE···[}/ .• M.ODIFIED · BY: -<. BY: :: . . ' .-..• C:<?,MM.f:NTS: •· .. . ·-· .· .. ···• ... . ..•. .. ·.· . :._.:.-::.,:_·· -···· . ··· ·· ··?vc•,.•·_ .. -· -:-. . .-:"·.=.::C::<:,:;\._:· ... · .-·· .. ··'//.==·· ·.·· .. ···;· :.: . ·?"_'· ... ·: ·", .... -.... ....... -··· .. · ·. ,-,·,,·:·_.:·:' ·. . ·.·. : : .... . This requirement may be waived by: 1. Property Services Section PROJECT NAME: _]5-'-"-reyyz=~e~'£i~@c.c.,.,.. _ __,_Af~ . .,_,, ,.,_,,(....,__,_1h=@:\Q.'--=~5 2. Public Works Plan Review Section 3. Building Section DATE: __ r._,,_/_B-,_/o_c_.!J ____ _ 4. Development Planning Section nCT Q:\WEB\P'MDEVSERV\F()m,s\Plann1ng\waivers.xls 2 05122/2006 ·• DEVELOPMENT SERVICES DIVISION WAIVER OF SUBMITTAL REQUIREMENTS FOR LAND USE APPLICATIONS LAND U$1: p!:.R,MIT SlJ.BMITT AL . . .REQUIREMENTS: •. .· . WAIVED , MORJl=IEQ · sv: · av: COMMENTS: . Calculations 1 Ce>lored Maps for Display\ · i .· .··. • \ .. . Construction Mitigation Description >ANO< D.e,:isity We>rksheel, . .. • < · C • .. • . .. ····· . >). Drainage Control Plan 2 Drainage Report 2 • . (:\ .. " ·.-:.: .. Elevations, Architectural , ANO, Environmental Ch~c:klist,i+· · ...•• ··•·· .. .. · Existing Covenants (Recorded Copy) , Existing Ea.~emerllt(R~d:OO Ccipy), Y · . : ",.",· ··-_. •: .. ,·;>,.,=·· .. =: . . . . . . ' Flood Hazard Data , ·::·:·---· . Geotechnical Report 2 ANO, Grading Pl<1!1, Cor\90ptu~j;j i . .. ... . Grading Plan, Detailed 2 ······· ., .. .. ·-:" .. ... . ...... . . ~-: .········ • iC ······ ·.·· ·::::,,:' •, ;'/ . . &·· ..•... · i .. •· .. Habitat Data Report\ .•.. ·. ..•. ( ' > ~~-~-4~eXc--+--'----""---+----"'---"""'"-- King County Assessor's Map Indicating Site , 6f::.) .· x< Jill.. ............ --;-; . ' ·.·· .. '• ;·· i. ;T t . ·. . . . ... .. LandscapePlan, Conce~iqa.1, . ··• •. • ...... . Landscape Plan, Detailed, .... .} •• ··.>···· . ii . _:: . . Legal Desctipiion .\ .· . ---.-',·.: .··· . ·.::· . :.:.·:·::. Map of Existing Sile Conditions , ..... .. .. , . ·.? .···· .. . .. •· •. . . . Monument Cards (one per monument) , Neighborhoc,d Detail Map ti .·. ·••• · .... . ··· · .. . . •• PROJECT NAME: 7?. ~rme,,-J iJYI 1o1.mb~ This requirement may be waived by: 1. Property Services Section DATE: CD /~l_c2& 2. Public Works Plan Review Section 3. Building Section 4. Development Planning Section ..... ,: ... •• .. ·.· .·· . > . .·· ... . ..: . . Q:\WEB\?W\OC.VSERV\Forms\Planning\wa1vers.xls 0512212006 . ' . ' . . . DENSITY ' . ' ' WORKSHEET City of Renton Development Services Division 1055 South Grady Way-Renton, WA 98055 Phone: 425430-7200 Fax: 425430-7231 1. Gross area of property: 1. :ze ( 4&(; square feet ' 2. Deductions: Certain areas are excluded from density calculations. These include: Public streets** Private access easements** Critical Areas• Total excluded area: 3. Subtract line 2 from line 1 for net area: 4. Divide line 3 by 43,560 for net acreage: 5. Number of dwelling units or lots planned: 14 1 f;;~£square feet ] 43 °r square feet ' 0 square feet 2. '21. '.r7 q-square feet , 3. . 5(o, 4-9 '2 square feet 4. --+1-3~0~-acres 6. Divide line 5 by line 4 for net density: 6. 2. 0. O = dwelling units/acre *Critical Areas are defined as "Areas detennined by the City to be not suitable for development and which are subject to the City's Critical Areas Regulations including very high landslide areas, protected slopes, wetlands or floodways." Critical areas buffers are not deducted/excluded. -Alleys (public or private) do not have to be excluded. Q;\\\'EB\PW\DEVSERWorms\Planning\density.doc LasJ updated: I l/0&12004 I · BREMERTON AVE. TOWNHOMES PRELIMINARY PLAT PROJECT NARRATIVE The proposed Bremerton Ave. Townhome Plat is an application for a 26 lot single family attached residential subdivision situated on 2 existing lots with a total area of 1.80 acres. It is located on the east side of Bremerton Ave. NE, approximately 300' south of NE 4th St. This project will require preliminary plat approval, a conditional use permit, a site plan approval and a SEPA determination by the City of Renton. The site is zoned CA and is within the NE 4th St. Corridor Business District. The proposed product will be a attached townhomes with a mixture of 2 and 3 unit buildings. Each unit will have its own lot. The surrounding properties to the north, east and west are also similarly zoned CA, with the property to the south being zoned R-8. The site is currently has 2 existing residences. All of the existing houses and garages/sheds will be removed. Both of the existing houses have driveways connected to Bremerton Ave. NE. A recently constructed plat, Ridgeview Court. is adjacent to the site, across Bremerton Ave. NE to the west. There are no wetlands, steep slopes or any sensitive areas on this site. There is a low depression along the north property line. This depression is approx. 1 O' deep and extends off-site to the north, to the adjacent Bank drive-thru driveway. This depression will be filled. The depression was mostly formed by the filling of the property to the east, as the grading for an approved multi-family development. A grading easement will be obtained from the adjacent property (Bank) to fill their portion. The steepest slope is approx. 25% along the south bank of the depression, northwest of the existing northern house. There are some similar slopes along most sides of the depression. The soils on the site are a silty sand, with some and silt loam. The site is dominated by residential landscaping with few trees. There are approx. 30 trees that are spread throughout the plat. The existing drainage from the north half of the site sheet flows into the depression. The existing drainage from the south half of the site sheet flows to the southwest corner of the site. The proposed use of the property as a 26 lot attached townhome residential subdivision will be consistent with the surrounding developments. All of the surrounding properties except for the parcels lo the south, are developed. The proposed lots will range in size from the minimum of 1426 SF to a maximum of 3337 SF (including access and drainage easements). The density of the plat is 20.0 units per acre in the CA zone. Access to the new lots will be from a new internal public street that runs east/west and is connected to Bremerton Ave. NE. and then ,. ' turns to the north and is connected to a public alley that then turns to the west and connects to Bremerton Ave. NE, to complete an internal loop. There will be a short public road stub to the southeast with a private road extension to serve the southeastern portion of the development. The new streets are proposed to be 32' wide residential streets with a 42' right-of- way. The reduced ROW will be wide enough to accommodafe the street and sidewalks on both sides. The reduced ROW width is needed to keep the net plat area at a maximum to stay under the maximum density. Eight joint driveways will be placed within easements and will be used to access most of the two unit buildings. Bremerton Ave. NE is currently improved on the west side (by Ridgeview Court) but not on the east side. The proposed plat will construct the east side of the street to complete the full road section. A new water main and sewer main will be installed in the new plat street. The water main will be run through the site and connected to a future water main in the multi-family project to the east. The water and sewer service is provided by the City of Renton. The finished lots are estimated to be worth approx. $150,000 for a total value of approx. 3.9 million dollars. The value of the lots with preliminary approval only is estimated to be $2.6 million dollars. The site will require substantial grading for the proposed road. The depression will need to be filled for approx. 8' in depth. The building pads for the lots will also require some minor grading but nothing over 4 feet. The main grading activity will be associated with the excavation for the detention vault and the fill for the depression. The estimated amount of grading is 500 CY for cut and 4000 CY for fill. It is anticipated that the site will use some of the cut material on-site, but the majority will be imported. There are numerous trees on the site. There are approx. 30 trees on the site. Most of the trees will need to be removed due to conflicts with the roads, utilities and building pads. Land that will be dedicated to the City include the internal public roads and the public alley. The lots will be sold by the developer to one or several builders or investors. The future builders will likely use model homes and temporary job trailers. DRISCOLL ARCHITECTS ..... URBAN CENTER DESIGN OVERLAY DISTRICT REPORT TO: To Whom it May Concern City of Renton Development Services Division 1055 South Grady Way Renton, WA 98055 FROM: Gregory D. Blount, DAps DATE: 12 October 2006 PROJECT LOCATION: 330 Bremerton Ave NE Renton, WA 98059 PROJECT NAME: Bremerton Avenue Townhouses RE: COPY: Urban Center Design Overlay District Report Marc Rousso Hugh Schaeffer; DAps Please accept the following as our Urban Center Design Overlay Distric:t_Reporj,_as a part of our Site Plan Review submittal. Our format follows the corresponding paragraph on The City's SPR submittal requirements. Pedestrian building entries: • Each unit entry is marked by a traditional covered porch along the roadway. All unit entries are on sidewalks that link throughout the site. These porches are detailed to a human scale. Transitions to surrounding development: • The three-story, residentially-scaled buildings are combined into (mostly) duplex and (2) triplex structures. These buildings are separated by yards and/or roadways from the adjacent developments and are similar to other nearby residential developments. Location and design of parking: • Each unit contains two garage parking stalls within the building. To the extent possible, the garage doors do not face the public street and alley on the site. Vehicular access: • The site plan was revised to provide a looped roadway system that aligns with NE 3'' Ct. across Bremerton Avenue (to the extent possible) at the City's request. Pedestrian Circulation: • Sidewalks are provided throughout the site and from the southeast corner to the northwest corner of the property, to link via the Bremerton Avenue sidewalk to the commercial property to the north. Common Space: • Green space, access and the private roadway will be maintained in common by the C.C.R.s attached to the properties. There may be no land held in common. Landscaping: • See Landscape Plans Building character and massing, rooflines. and materials: • Building character: Traditional residential detailing, fenestration and massing with attached entry porches and (to the extent possible) the garage doors off the public street/public alley. The buildings will appear clearly residential in scale considering the duplex and triplex configurations • Rooflines: Traditional gables will define each individual unit. Entries will be marked by shed or gabled roof forms on the porches. Roof materials will be "architectural" asphalt shingle. • Materials: The buildings will have lapped. board-and-batten and shingle siding with traditional, contrasting trim. Windows will be beige vinyl with trim. Roofs will be as above. X \2005direc/\0516\SPR _ OverlayD1strrc/Report. DOC A Professional Services Corporation 115 Bell St. Seattle, WA 98121 (206)441-7705 Fax: (206)441-5373 E-Mail: daps@drisarch.com TO: DRISCOLL ARCHITECTS ... CONDITIONAL USE PROJECT NARRATIVE Whom it May Concern City of Renton Development Services Division 1055 South Grady Way Renton, WA 98055 FROM: Gregory D. Blount, DAps DA TE: 12 October 2006 PROJECT LOCATION: 330 Bremerton Ave NE Renton, WA 98059 PROJECT NAME: Bremerton Avenue Townhouses Conditional Use Project Narrative Marc Rousso RE: COPY: Hugh Schaeffer: DAps Please accept the following as our Project Narrative, apacloLoJ.Jr.Condilional Ilse f'.eanitsu.brni!taL Our format follows the Project Narrative paragraph on The City's Conditional Use Permit Application submittal requirements. Project name, size and location of site: Name: Bremerton Avenue Townhouses Size: 26 Units in 12 Buildings on 1.86 Acres. Average unit size approx. 2,200 square feet. Location: 330 Bremerton Avenue, NE (for legal description of property see Survey) Land use permits required for proposed project Site Plan Review Plat Zoning designation of the site and adjacent properties Site: CA (Commercial Arterial) NE 4th St. Corridor North: CA (Commercial Arterial) NE 4th St. Corridor District South R-8 East: CA (Commercial Arterial) NE 4th St. Corridor West: CA (Commercial Arterial) NE 4th St. Corridor Current use of the site and any existing improvements Single Family (2 units w/ accessory structures) Special site features (i.e. wetlands, water bodies, steep slopes) None Statement addressing soil type and drainage conditions See Soils Report Proposed use of the property and scope of the proposed development 26 Unit Townhouse Development For plats indicate the proposed number, net density and range of sizes (net lot area) of the new lots 26 lots 20.0 units per acre Access 1,426 smallest lot 3,337 largest Two points of access from Bremerton Ave. with looped roadway system (public alley and street) A Professional Services Corporation 115 Bell St Seattle, WA 98121 (206)441-7705 Fax: (206)441-5373 E-Mail: daps@drisarch.com -- Conditional Use Permit Pr, Narrative Bremerton Avenue Townhouses 12 October 2006 Proposed off-site improvements (i.e. installation of sidewalks, fire hydrants, sewer main, etc.) Street improvements for length of Bremerton Ave. frontage per City standards. Utility extensions as required. Total estimated construction cost and estimated fair market value of the proposed project $6,600,000.00 Estimated quantities and type of materials involved if any fill or excavation is proposed Cut and fill (gross excavation): 4,000 cu. yards fill, 500 cu. yards cut (net import). If unsuitable bearing materials are found additional structural fill will be imported as necessary (no unsuitable material is known). Capillary and compactable sub-base will be provided under roadways and slabs-on-grade as required (sand, gravel) Number, type and size of any trees to be removed See landscape plan Explanation of any land to be dedicated to the City New public street and alley as shown Any proposed job shacks, sales trailers, and/or model homes Not known Any proposed modifications being requested (include written justification) Front setback due to site constraints (requirements for public looped roadway system) is reduced/eliminated by residential entry porches located therein. Front setback exception/reduction required. X. \2005d1recl\0515\0516C U _ ProJec/Narrative. DOC BREMERTON AVE. TOWNHOME PRELIMINARY PLAT CONSTRUCTION MITIGATION DECRIPTION The Bremerton Ave. Townhome preliminary plat is a 26 lot attached residential subdivision located on the east side of Bremerton Ave. NE. It is anticipated that the construction of the plat will begin in the fall of 2007 and continue through the winter of that same year. The construction of the buildings will likely begin in the late spring, early summer of 2008. The building construction will likely continue for approx. l year, depending upon the local demand for housing. The construction will occur from 7:00 AM to 6:00 PM, Monday through Friday and possibly on Saturday. If work is to be outside of these hours, previous approval will be received from the City. The proposed hauling and construction traffic routes will be along 1-405 to the Maple Valley highway interchange. The traffic will then proceed north on Sunset Ave. and turn east on NE 4th St., up into the Renton Highlands area. The traffic will then turn south on Bremerton Ave. NE and proceed south on Bremerton Ave. NE for approx. 300 ft. to the site. Construction that occurs during the dry summer period can produce dust. This will be controlled using water trucks. Impacts to traffic will be regulated by having a traffic control plan approved by the City for work within the existing ROW. The tracking of dirt and mud will be reduced by constructing a quarry spoil construction access point as one of the initial construction items of development. STREAM ASSESSMENT The generalized City drainage maps show a stream crossing the site. The map (attached) shows the stream along the north property line and flowing from east to west. It should be noted that these are general maps and may not reflect the actual field conditions. The actual site conditions are that no stream exists on the site. The location of the stream, as shown on the City maps, is at the location of the depression shown on the site specific topography and preliminary development plans. In fact, there is no culvert or means for a stream to flow to the west under Bremerton Ave. NE. This street creates a blockage of any flow towards the west. There likely was s slight flow to the east. as indicated by the field survey points for this site, but this was only a marginal swale/surtace flow feature. The recent grading of the adjacent multi-family site east of the subject site, has blocked any outlet for the depression to the east. The drainage system for the bank. to the north. flows into the depression. The on-site flows and the bank discharge created a substantial drainage impoundment pond during the last winter. This is the first rainy season that the site has had since the grading/blockage to the east. In summary, there is no stream on the site. The construction of Bremerton Ave. NE, many years ago, without a culvert would have blocked any stream flow as indicated on the City general maps. Ii DEVELOPMENT SERVICES DIVISION ENVIRONMENTAL CHECKLlST City of Renton Development Services Division 1055 South Grady Way, Renton, WA 98055 Phone: 425-430-7200 Fax: 425-430-7231 PURPOSE OF CHECKLIST: The State Environmental Policy Act (SEPA}, Chapter 43.21C RCW, requires all governmental agencies to consider the environmental impacts of a proposal before making decisions. An Environmental Impact Statement (EIS) must be prepared for all proposals with probable significant adverse impacts on the quality of the environment. The purpose of this checklist is to provide information to help you and the agency identify impacts from your proposal (and to reduce or avoid impacts from the proposal, if it can be done) and to help the agency decide whether an EIS is required. INSTRUCTIONS FOR APPLICANTS: This environmental checklist asks you to describe some basic information about your proposal. Governmental agencies use this checklist to determine whether the environmental impacts of your proposal are significant, requiring preparation of an EIS. Answer the questions briefly, with the most precise information known, or give the best description you can. You must answer each question accurately and carefully, to the best of your knowledge. In most cases, you should be able to answer the questions from your own observations or project plans without the need to hire experts. If you really do not know the answer, or if a question does not apply to your proposal, write "do not know'' or "does not apply". Complete answers to the questions now may avoid unnecessary delays later. Some questions ask about governmental regulations, such as zoning, shoreline, and landmark designations. Answer these questions if you can. If you have problems, the governmental agencies can assist you. The checklist questions apply to all parts of your proposal, even if you plan to do them over a period of time or on different parcels of land. Attach any additional information that will help describe your proposal or its environmental effects. The agency to which you submit this checklist may ask you to explain your answers or provide additional information reasonably related to determining if there may be significant adverse impact. USE OF CHECKLIST FOR NONPROJECT PROPOSALS: Complete this checklist for nonproject proposals, even though questions may be answered "does not apply." IN ADDITION, complete the SUPPLEMENTAL SHEET FOR NONPROJECT ACTIONS (part D). For nonproject actions (actions involving decisions on policies, plans and programs}, the references in the checklist to the words "project," "applicant," and "property or site" should be read as "proposal," "proposer," and "affected geographic area," respectively. l:IESM-JOBSI 1241 \0061005\documentlenvchlst1 .doc10/02/06 A. BACKGROUND 1. Name of proposed project, if applicable: Bremerton Ave. Townhomes Preliminary Plat 2. Name of applicant: Seattle Redevelopment, LLC 3. Address and phone number of applicant and contact person: 4. Owners: Applicant: Agent: Alice Knight, 330 Bremerton Ave. NE, Renton, WA 98059 Charles Ratzsch, 320 Bremerton Ave. NE, Renton, WA 98059 Seattle Redevelopment, LLC Attn: Marc Rousso PO Box 2566 Renton, WA 98056 425-226-9100 ESM Consulting Engineers, LLC Attn: Eric LaBrie 33915 1st Way S., Ste 200 Federal Way, WA 98003 253-838-6113 Date checklist prepared: September 26, 2006 5. Agency requesting checklist: City of Renton Development Services Division 6. Proposed timing or schedule (including phasing, if applicable): Checklist Review: 3 months Land Use Review/Hearing: 3-6 months Engineering Review/Permitting: 4 months Plat Construction: 4 months Home construction is expected to begin in the summer or fall of 2007. 7. Do you have any plans for future additions, expansion, or further activity related to or connected with this proposal? If yes, explain. No. 8. List any environmental information you know about that has been prepared, or will be prepared, directly related to this proposal. Level 1 Downstream Analysis prepared by Jaeger Engineering, dated September 22, 2006. Bliss Wetland Reconnaissance Report by Chad Armour & Assoc., dated August 16, 2006. Traffic Analysis/Letter by Gibson Traffic Consultants, dated September, 2006. Geotechnical Engineering Study by Earth Solutions NW, LLC, dated July 19, 2006 9. Do you know whether applications are pending for governmental approvals of other proposals directly affecting the property covered by your proposal? If yes, explain. None are known. l:\ESM~JOBS\ 1241 \006\005\document\envchlst1 .doc 2 10. List any governmental approvals or permits that will be needed for your proposal, if known. -SEPA Review -Preliminary/Final Plat Review -Conditional Use Permit -Site Plan Review -Engineering Review -Right-of-way Use Permit -Building Permit -NPDES Permit 11. Give brief, complete description of your proposal, including the proposed uses and the size of the project and site. This project is proposing to develop 2 existing parcels into 26 townhomes within 12 buildings. The site is approximately 1.86 acres and is zoned C4 {Commercial Arterial). The proposed lot sizes will range between 30'-45' x 65'-110' and will typically be 3,400 to 6,400 square feet. There are two existing houses on site, including out buildings which will be demolished to accommodate the proposed development The proposal includes plans for a storm drainage vault to comply with the City's storm drainage requirements. The developer will pay a fee in lieu of the recreation requirements for the City. 12. Location of the proposal. Give sufficient information for a person to understand the precise location of your proposed project, including a street address, if any, and section, township, and range if known. If a proposal would occur over a range of area, provide the range or boundaries of the site(s). Provide a legal description, site plan, vicinity map, and topographic map, if reasonably available. While you should submit any plans required by the agency, you are not required to duplicate maps or detailed plans submitted with any permit applications related to this checklist. The proposed subdivision is located in the City of Renton on the northeast Hill of Renton. The project is more specifically located off of Bremerton Avenue NE south of NE 4" Street The project is within a portion of the Northwest ~ of Section 15, Township 23 North, Range 5 East, of the Willamette Meridian. The site address is: 330 Bremerton Avenue NE B. ENVIRONMENTAL ELEMENTS 1. EARTH a. General description of the site (circle one): flat, rolling. hilly, steep slopes, mountainous, other _____ _ b. What is the steepest slope on the site (approximate percent slope?) The steepest slope on the property is approximately 21 percent in the northeastern comer of the site. The majority of the site is relatively flat I :\ESM-JOBS\ 1241 \006\005\document\envchlst1 .doc 3 c. What general types of soils are found on the site (for example, clay, sand, gravel, peat, muck)? If you know the classification of agricultural soils, specify them and note any prime farmland. The soils onsite consist of alderwood gravelly sandy loam (AgC) soils according to the King County Soil Survey. d. Are there surface indications or history of unstable soils in the immediate vicinity? If so, describe. There are no known surface indications of unstable soils on, or in the immediate vicinity of the proposed site location. For more information please see the Geotechnical Engineering Study by Earth Solutions NW, LLC, dated July 19, 2006. e. Describe the purpose, type, and approximate quantities of any filling or grading proposed. Indicate source of fill. Grading will be limited to the construction of the proposed roads, lots, water, sewer, other utilities, and the proposed detention facility. There will be approximately 4,000 cubic yards of fill, and 500 cubic yard of cut within this project. Any additional import or export of material necessary for this project will be approved at final engineering and obtained from a City approved site. f. Could erosion occur as a result of clearing, construction, or use? If so, generally describe. Some erosion could occur during clearing and grading operations associated with this project. To minimize the impacts of the project, appropriate erosion control measures will be reviewed and approved by the City prior to construction activity associated with this project. g. About what percent of the site will be covered with impervious surfaces after project construction (for example, asphalt or buildings)? The preliminary plat shows approximately 670 linear feet of new roads associated with this project resulting in approximately 24,600 sf of new impervious road surfaces. The total impervious surface for the site is approximately 58,400 square feet of impervious surfaces, or 72 percent of the site is proposed. h. Proposed measures to reduce or control erosion, or other impacts to the earth, if any: During construction, various measures are expected to be used to control erosion. These methods include construction during the dry season, the use of silt fences and hay bails, and re-vegetation of disturbed areas. Specific temporary erosion and sediment control measures will be reviewed and approved by the County prior to construction. l:\ESM-JOBS\ 1241 \006\005\document\envchlst1 .doc 4 2. AIR a. What types of emissions to the air would result from the proposal (i.e., dust, automobile, odors, industrial wood smoke) during construction and when the project is completed? If any, generally describe and give approximate quantities if known. During construction, short-term emissions may occur, induding dust and vehide emissions from construction related equipment. After construction, emissions from this project would primarily result from automobile usage as is typical with residential development b. Are there any off-site sources of emission or odor that may affect your proposal? If so, generally describe. None to our knowledge. c. Proposed measures to reduce or control emissions or other impacts to air, if any: Dust emissions will be controlled during site construction by the use of best management practices, including periodic watering of disturbed areas. The project will not rely upon wood burning fireplaces as the primary source of heat for the new homes. All new homes will use natural gas and/or electricity to provide heat, reducing emissions caused by wood burning fires. 3. WATER a. Surface Water: 1) Is there any surface water body on or in the immediate vicinity of the site (including year-round and seasonal streams, saltwater, lakes, ponds, wetlands)? If yes, describe type and provide names. If appropriate, state what stream or river it flows into. Not to our knowledge. 2) Will the project require any work over, in, or adjacent to (within 200 feet) the described waters? If yes, please describe and attach available plans. No. 3) Estimate the amount of fill and dredge material that would be placed in or removed from surface water or wetlands and indicate the area of the site that would be affected. Indicate the source of fill material. Not applicable. 4) Will the proposal require surface water withdrawals or diversions? Give general description, purpose, and approximate quantities if known. No. l:\ESM-JOBS\ 1241 \006\005\document\envchlst1 .doc 5 b. 5) Does the proposal lie within a 1 DO-year flood plain? If so, note location on the site plan. No. 6) Does the proposal involve any discharges of waste materials to surface waters? 1) If so, describe the type of waste and anticipated volume of discharge. No. Ground Water: Will ground water be withdrawn, or will water be discharged to ground water? Give general description, purpose, and approximate quantities if known. No. 2) Describe waste material that will be discharged into the ground from septic tanks or other sources, if any (for example: Domestic sewage; industrial, containing the following chemicals ... ; agricultural; etc.). Describe the general size of the system, the number of such systems, the number of houses to be served (if applicable), or the number of animals or humans the system(s) are expected to serve. None. c. Water Runoff (including storm water): 1) Describe the source of runoff (including storm water) and method of collection and disposal, if any (include quantities, if known). Where will this water flow? Will this water flow into other waters, If so, describe. The proposed project will provide approximately 670 linear feet of new roads, 1 O new rooftops and other impervious surfaces which will generate new stonnwater runoff. The increased runoff from these surfaces will be collected via catch basins and routed in underground pipes to a new underground stormwater detention facility. The new homes will either connect their downspouts to the stonn drainage system in the street, or provide an onsite infiltration area for this runoff. (Please see Level 1 Downstream Analysis prepared by Jaeger Engineering, dated September 22, 2006). 2) Could waste material enter ground or surface waters? If so, generally describe. Waste materials are generally limited to petroleum products from the road surfaces. The water quality portion of the stonnwater facilities is specifically designed to prohibit these materials from entering the downstream system. d. Proposed measures to reduce or control surface, ground, and runoff water impacts, if any: All development and engineering requirements imposed by the City to control the impacts to the hydrology of the area will be performed by the proponent. These include design of the stormwater facilities pursuant to the 2005 KCSWDM. I :\ESM-JOBS\ 1241 \006\005\document\envchlst1 .doc 6 4. PLANTS a. Check or circle types of vegetation found on the site: .2QL deciduous tree: alder, maple, aspen, other walnut .2QL evergreen tree: fir, cedar, pine, other .2QL shrubs .2QL grass __ pasture __ crop or grain __ wet soil plants: cattail, buttercup, bullrush, skunk cabbage, other __ water plants: water lily, eel grass, milfoil, other __ other types of vegetation b. What kind and amount of vegetation will be removed or altered? The majority of the existing vegetation will be removed for the grading and construction of the project. The project will attempt to retain as many significant trees as reasonably possible in areas near the rear of future lots and around the perimeter of the site. This project will meet the appropriate City requirements with respect to tree retention and/or mitigation. c. List threatened or endangered species known to be on or near the site. None, to our knowledge. d. Proposed landscaping, use of native plants, or other measures to preserve or enhance vegetation on the site, if any: The project will attempt to incorporate native plants in the final landscaping design where practical on the site. 5. ANIMALS a. Circle any birds and animals which have been observed on or near the site or are known to be on or near the site: Birds: hawk, heron, eagle, songbirds, other~-,-------- Mammals: deer, bear, elk, beaver, other: ,--:..:R'"'o:.::d:.::e:.cn:.::ts=-------- Fish: bass, salmon, trout, herring, shellfish, other ______ _ b. List any threatened or endangered species known to be on or near the site. None, to our knowledge. c. Is the site part of a migration route? If so, explain Not to our knowledge. d. Proposed measures to preserve or enhance wildlife, if any: None are proposed at this time; however, rodents and small animals will undoubtedly inhabit the open spaces and buffers within this project. l:\ESM-JOBS\ 1241 \006\005\document\envchlst1 .doc 7 6. ENERGY AND NATURAL RESOURCES a. What kinds of energy (electric, natural gas, oil, wood stove, solar) will be used to meet the completed project's energy needs? Describe whether it will be used for heating, manufacturing, etc. Electricity and/or natural gas will be used to meet the project's energy needs for light and heat. b. Would your project affect the potential use of solar energy by adjacent properties? If so, generally describe. No. c. What kinds of energy conservation features are included in the plans of this proposal? List other proposed measures to reduce or control energy impacts, if any: Construction of the new homes will meet or exceed the necessary energy requirements of the Northwest Energy Code and those adopted by the City. 7. ENVIRONMENTAL HEAL TH a. Are there any environmental health hazards, including exposure to toxic chemicals, risk of fire and explosion, spill, or hazardous waste, that could occur as a result of this proposal? If so, describe. No. 1) Describe special emergency services that might be required. Not applicable. 2) Proposed measures to reduce or control environmental health hazards, if any: None are proposed at this time. b. Noise 1) What types of noise exist in the area which may affect your project (for example: traffic, equipment, operation, other)? None, to our knowledge. l:\ESM-JOBS\ 1241 \006\005\document\envchlst1 .doc 8 2) What types and levels of noise would be created by or associated with the project on a short-term or a long-term basis (for example: traffic, construction, operation, other)? Indicate what hours noise would come from the site. Construction noises will likely occur on a short-term basis due to the use of heavy equipment, nailing guns and saws. This noise would be limited to typical construction hours and the City's noise ordinance. On a long-term basis, noise would be limited to typical residential uses, induding cars and children. 3) Proposed measures to reduce or control noise impacts, if any: Increased noise levels due to construction will be restricted to the abovementioned hours to reduce any impacts to the neighboring residents. 8. LAND AND SHORELINE USE a. What is the current use of the site and adjacent properties? The site is currently used as two single-family residential properties with associated out buildings. The uses of adjacent properties indude single-family residential, commercial, and undeveloped land. b. Has the site been used for agriculture? If so, describe. Not to our knowledge. c. Describe any structures on the site. There are homes on both parcels associated with this project with footprints of approximately 1,200 sf and 2,500 sf. Each home has associated garages and other out buildings induding carports and sheds. d. Will any structures be demolished? If so, what? Yes, both of the existing homes and all of the associated out buildings will be demolished to make way for the new development e. What is the current zoning classification of the site? The current zoning is Commercial Arterial, C4. f. What is the current comprehensive plan designation of the site? The current comprehensive plan designation of the site is Commercial Corridor. g. If applicable, what is the current shoreline master program designation of the site? Not applicable. l:\ESM-JOBS\ 1241 \006\005\document\envchlst1 .doc 9 h. Has any part of the site been classified as an "environmentally sensitive" area? If so, specify. No. i. Approximately how many people would reside or work in the completed project? Based on a household occupancy rate of 2.5 people per single-family residence, we expect that approximately 65 people will reside in the finished project. j. Approximately how many people would the completed project displace? Based on a household occupancy rate of 2.5 people per single-family residence, we expect that approximately 5 people will be displaced by this project. k. Proposed measures to avoid or reduce displacement impacts, if any: None are proposed at this time. I. Proposed measures to ensure the proposal is compatible with existing and projected land uses and plans, if any: Tne proposed 26-lot subdivision is consistent with recent development in the area, current zoning, and comprehensive plan designations. Tne conditional use permit submitted with this application will also ensure compatibility with adjacent uses. 9. HOUSING a. Approximately how many units would be provided, if any? Indicate whether high, middle, or low-income housing. It is expected that the project will provide up to 26 new multifamily residential units in the middle income level. b. Approximately how many units, if any, would be eliminated? Indicate whether high, middle, or low-income housing. Tnere are two existing residences currently on-site, all within the medium income levels. Tnese homes will be eliminated to accommodate the new development c. Proposed measures to reduce or control housing impacts, if any: None are proposed at this time. l:\ESM-JOBS\ 1241 \0061005\document\envchlst1 .doc 10 10. AESTHETICS a. What is the tallest height of any proposed structure(s), not including antennas; what is the principal exterior building material(s) proposed. The City's zoning code restricts the building heights of residential structures in the C4 zone to 35~ Exterior materials will typically consist of natural-looking products, including wood or wood like siding with brick, rock, or shingle accents. Specific materials will be determined by the home builder at the time of building permit and will comply with applicable City regulations and the CUP. b. What views in the immediate vicinity would be altered or obstructed? None. c. Proposed measures to reduce or control aesthetic impacts, if any: None are proposed at this time. 11. LIGHT AND GLARE a. What type of light or glare will the proposal produce? What time of day would it mainly occur? Light would occur during evening and night time hours and would be limited to street lights and house lights. b. Could light or glare from the finished project be a safety hazard or interfere with views? No. c. What existing off-site sources of light or glare may affect your proposal? None. d. Proposed measures to reduce or control light and glare impacts, if any: None are proposed at this time. 12. RECREATION a. What designated and informal recreational opportunities are in the immediate vicinity? The area has both parks and schools in the vicinity. Two parks in the area are Kiwanis Park and Maplewood Community/Neighborhood Park. The school in the immediate vicinity is Maplewood Heights Bementary. These facilities provide recreation space such as trails, play grounds, sports fields and basketball courts. l:\ESM-JOBS\ 1241 \006\005\document\envchlst1 .doc 11 b. Would the proposed project displace any existing recreational uses? If so, describe. No. c. Proposed measures to reduce or control impacts on recreation, including recreation opportunities to be provided by the project or applicant, if any: The project is proposing to pay the City's fee in lieu of providing recreational space to enhance cutTent City recreational facilities. 13. HISTORIC AND CULTURAL PRESERVATION a. Are there any places or objects listed on, or proposed for, national state, or local preservation registers known to be on or next to the site? If so, generally describe. Not to our knowledge. b. Generally describe any landmarks or evidence of historic, archaeological, scientific, or cultural importance known to be on or next to the site. Not to our knowledge. c. Proposed measures to reduce or control impacts, if any: None are proposed at this time. 14. TRANSPORTATION a. Identify public streets and highways serving the site, and describe proposed access to the existing street system. Show on site plans, if any. The proposed subdivision will be accessed from Bremerton Ave. NE Highway access to I-405 will be via NE -11' St. which connects to Bremerton Ave. NE {Please see Preliminary Plat for proposed access points). b. Is site currently served by public transit? If not, what is the approximate distance to the nearest transit stop? The nearest public bus access is on NE ,ff' St and Duvall Ave. (bus route 908). This bus stop is approximately 0.20 miles northeast of the proposed subdivision. c. How many parking spaces would the completed project have? How many would the project eliminate? Assuming a minimum of 2 parking spaces per household (2-car garage), there will be at least 52 parking spaces provided upon completion of this development, approximately 4 parking spaces will be eliminated by this proposal, equaling a total of 48 new parking spaces. l:\ESM-JOBS\ 1241 \006\005\document\envchlst 1.doc 12 d. Will the proposal require any new roads or streets, or improvements to existing roads or streets, not including driveways? If so, generally describe (indicate whether public or private? Approximately 385 linear feet of new public roads and 683 linear feet of private roads, alleys and joint-use driveways will be constructed with this project. With the exception of the joint-use driveways and the private road, all proposed roads and alleys within the project will be public roads. The street frontage along Bremerton Ave. NE will all have to be improved with curb, gutter & sidewalk. e. Will the project use (or occur in the immediate vicinity of) water, rail, or air transportation? If so, generally describe. No. f. How many vehicular trips per day would be generated by the completed project? If known, indicate when peak volumes would occur. According to the Institute of Traffic Engineers Manual, :11' Edition, there will be an average of approximately 10 vehicular trips per day, per household. For the entire project of 24 new lots, that would amount to approximately 240 new average daily trips. Peak volumes would most likely occur during typical rush hour times of 7:00 -9:00 AM and 4:00 -6:00 PM and would add approximately 24 AM peak hour trips. Please see the Traffic Analysis/Letter by Gibson Traffic Consultants, dated September, 2006 for more information. g. Proposed measures to reduce or control transportation impacts, if any: The applicant will be responsible for appropriate traffic mitigation fees, which will offset some of the impacts of the subdivision. Other mitigation includes the construction of frontage improvements and new roads to serve the project. 15. PUBLIC SERVICES a. Would the project result in an increased need for public services (for example: fire protection, police protection, health care, schools, other)? If so, generally describe. There would be a minimal increased need for fire and police protection due to an additional 24 new lots in the area. Also, there will be a minimal impact on the present school system. b. Proposed measures to reduce or control direct impacts on public services, if any. Property taxes, building permits and school impact mitigation fees generated from these residences are expected to mitigate impacts incurred from this development. l:\ESM-JOBS\ 1241 \006\005\document\envchlst1 .doc 13 16. UTILITIES a. b. Circle utilities currently available at the site: electricity, natural gas, water, refuse service, telephone, sanitary sewer, septic system, other cable television Describe the utilities that are proposed for the project, the utility providing the service, and the general construction activities on the site or in the immediate vicinity which might be needed. Electricity: Gas: Water: Refuse: Telephone: Sewer: Cable: Puget Sound Energy Puget Sound Energy City of Renton and King County Water Dist. #90 Waste Management Qwest Communications City of Renton Comcast C. SIGNATURE I, the undersigned, state that to the best of my knowledge the above information is true and complete. It is understood that the lead agency may withdraw any declaration of non-significance that ii might issue in reliance upon this checklist should there be any willful misrepresentation or willful lack of full disclosure on my part. k~ib-f Proponent: Name Printed: 8¢<c.._. (,,. UJ.:O.Qv, Date: IQ . 'Z. <?<;,-: l:\ESM-JOBS\ 1241 \006\005\document\envchlst1 .doc 14 D. SUPPLEMENTAL SHEETS FOR NONPROJECT ACTIONS (These sheets should only be used for actions involving decisions on policies, plans and ro rams. You do not need to fill out these sheets for ro·ect actions. Because these questions are very general, it may be helpful to read them in conjunction with the list of the elements of the environment. When answering these questions, be aware of the extent the proposal, or the types of activities likely to result from the proposal, would affect the item at a greater intensity or at a faster rate than if the proposal were not implemented. Respond briefly and in general terms. 1. How would the proposal be likely to increase discharge to water; emissions to air, production, storage, or release of toxic or hazardous substances; or production of noise? Proposed measures to avoid or reduce such increases are: 2. How would the proposal be likely to affect plants. animals, fish, or marine life? Proposed measures to protect or conserve plants, animals, fish, or marine life are: 3. How would the proposal be likely to deplete energy or natural resources? Proposed measures to protect or conserve energy and natural resources are: 4. How would the proposal be likely to use or affect environmentally sensitive areas or areas designated (or eligible or under study) for governmental protection; such as parks, wilderness, wild and scenic rivers, threatened or endangered species habitat, historic or cultural sites, wetlands, flood plains, or prime farmlands? Proposed measures to protect such resources or to avoid or reduce impacts are: 5. How would the proposal be likely to affect land and shoreline use, including whether it would allow or encourage land or shoreline uses incompatible with existing plans? Proposed measures to avoid or reduce shoreline and land use impacts are: I :\ESM-JOBS\ 1241 \006\005\document\envchlst1 .doc 15 6. How would the proposal be likely to increase demands on transportation or public services and utilities? Proposed measures to reduce or respond to such demand(s) are: 7. Identify, if possible, whether the proposal may conflict with local, state, or federal laws or requirements for the protection of the environment. SIGNATURE I, the undersigned, state that to the best of my knowledge the above information is true and complete. It is understood that the lead agency may withdraw any declaration of non-significance that it might issue in reliance upon this checklist should there be any willful misrepresentation or willful lack of full disclosure on my part. Proponent: Name Printed: Date: ENVCHLST.DOC REVISED 6/98 l:\ESM-JOBS\ 1241 \006\005\document\envchlst1 .doc 16 ,_ ,, ;1 § ""'i'lm'I' .......... .. .. i I • i s • '~ i!i ·-~-~ ~ I ' ~---~ I •!!1 ,11 l 1:, j!, ' 'Eil •;: i • '"' 111 /ii • i -., le f: ill ,h JfR 1i~ r' ,,; • I .; ~1 • ' ~ n " ~ C ' ; I ~ I • I a " ' l BREMERTON A VE. T0WNH0M£S ;,o wrs PRELIMINARY PLAT MAP JJC &: J20 eREM[:<':T'JN Avt. NE 1!!•!11 ':I . ~ 11111" ~ ~ll; ll;r.; ii i'!! a !j ·!" ', i ; ~ ' • i ' ., ' ~, ' 1-----~ ' 5 .JAEGER ENGINEERING 9479 Sou!h ZD4!h Ploc~ K~nt. WA. 980JI Phono No. (=) /1!,C,.-(Jg,J4 faK Na. (l!>:J) l!S0-0155 )> " 0 ,, =' 0 z ~ =' 0 z AFFIDAVIT OF INSTALLATION OF PUBLIC INFORMATION SIGN City of Renton Development Services Division 1055 South Grady Way, Renton, WA 98055 Phone: 425-430-7200 Fax: 425-430-7231 STATE OF WASHINGTON COUNTY OF KING I ,_ duly sworn on oath, deposes and says: -·,c 1. \.J~.· being first 1. On the Z day of ____ __;_ __ , 20_{_j_._:_, I installed _ ____.__ public information sig_n(s) and plastic flyer box on the property located at ___ ;__...._:__~·,__, '---.__. :_·_,_,._--'-'----'----''--"ac----for the following project: ' I' -i, .... Project name ,' (. t.· /. __ i_ ,_ , r ·. -1 r 11 Owner Name 2. I have attached a copy of the neighborhood detail map marked with an "X" to indicate the location of the installed sign. 3. This/these public information sign(s) was/were constructed and installed in locations in conformance with the requirements of Chapter 7 Title 4 of Renton Municipal Code. i . ) . ·, / .i ·-_>:..... ,{-: Installer Signature te of Washington, residing at i2-El::'.Tl:i ___ " __ _.) My commission expires on t' /t5 /ot,.,, > C:\Documcnts and Scttings\KrisL\Local Scttmgs\Tempora1") lnk111d l'iks\OLK95\pubsign.<lnc ()9/2)/()(J Map Output @ King County :'.,'/!:lJHIOUJ9i i £•/S2!0UU3·J ! 61B2!001'H'! i ~· 32[,.fODl'.JlO d Jl!'.,.f(.100/0 .2J2MHJL11U I I i 232trW:JfJf:iLJ / 2326.fOUOJO n~·::..rooosLJ I 2J2Mvoo:,!J i l I ' I 2:1254'00!:13~1 : ' ' NLJNI.JCI '.23:.!bfUU..f10 :.C.'32~•WU1:i.'O i ::"::l.:'MD!J>fLlD ,ii~!i:f'i1U.{ki : ~ Sel9d9d P.;;,~;eb l ::• Cmmly Boundary x Mountain Paa~,s S1N:1i:!IS Fomsl Produc.b.Jn Dislfd Boundary I /2}/l}U(IO(.l{.I_J ! iMAP Leqend 162:Jifj~(}/1 0 1623[)59031 .fll!,1600260 •f21Y6002JO •f?1!,1i'J(J0}410 1} / 96[}026!.I Nf. 2NU Cl .f.!1Y6VOJ3LI ! •f21Yf.i[.!02JO' / 4'2Hl60LJCS0 \ 12 J ~6001!,,I[) 225ft ,,,, Agnct.lM.ura! Pr,Jducfo:1 D,st!ict Boundary ,, IJrt:rnn Growl!! Area :_,,,fl D lakes and LoF'J"" R,~-;;ir, '!\, ,. SI roams D Tribal lanrJs P.arcefs lnoorµowtnd li.r.;frJ Page I of I ' 1:'.!2306!.IOti! i ' /62JQ69Ul2 he information included on this map has been compiled by King County staff from a variety of sources and is subject to change without notice. King County makes no representations or warranties, express or implied, as to accuracy. completeness, timeliness, or rights to the use of such information. King County hall not be liable for any general, special, indirecl incidental, or consequential damages including, but not limited to, lost revenues or lost profits resulting from he use or misuse of the information contained on this map. Any sale of this map or information on lhis map is prohibited except by written permission of King aunty. Date: 9-26-2006 Source: King County iMAP -Property Information (hUp'//www.rnetrokc.gov/GIS/iMAP) COMMENTS: 320/330 Bremerton Avenue NE http://www5 .metro kc.gov /serv let/com.csri.esrimap. Esrimap 1 ServiceName=overview&ClientVersion=4. 0... 9/26/2006 • Printed: I 0-17-2006 Payment Made: CITY OF RENTON 1055 S. Grady Way Renton, WA 98055 Land Use Actions RECEIPT Permit#: LUA06-133 CCT Receipt Number: R0605224 Total Payment: 10/17/200611:SSAM 4,000.00 Payee: SEATTLE REDEVELOPMENT LLC Current Payment Made to the Following Items: Trans Account Code Description 5009 000.345.81.00.0006 Conditional Use Fees 5010 000.345.81.00.0007 Environmental Review 5011 000.345.81.00.0008 Prelim/Tentative Plat 5020 000.345.81.00.0017 Site Plan Approval Payments made for this receipt Trans Method Description Amount Payment Check 1224 4,000.00 Account Balances Amount 500.00 500.00 2,000.00 1,000.00 Trans Account Code Description Balance Due 3021 303.000.00.345.85 Park Mitigation Fee 5006 000.345.81.00.0002 Annexation Fees 5007 000.345.81.00.0003 Appeals/Waivers 5008 000.345.81.00.0004 Binding Site/Short Plat 5009 000.345.81.00.0006 Conditional Use Fees 5010 000.345.81.00.0007 Environmental Review 5011 000.345.81.00.0008 Prelim/Tentative Plat 5012 000.345.81.00.0009 Final Plat 5013 000.345.81.00.0010 PUD 5014 000.345.81.00.0011 Grading & Filling Fees 5015 000.345.81.00.0012 Lot Line Adjustment 5016 000.345.81.00.0013 Mobile Home Parks 5017 000.345.81.00.0014 Rezone 5018 000.345.81.00.0015 Routine Vegetation Mgmt 5019 000.345.81.00.0016 Shoreline Subst Dev 5020 000.345.81.00.0017 Site Plan Approval 5021 000.345.81.00.0018 Temp Use or Fence Review 5022 000.345.81.00.0019 Variance Fees 5024 000.345.81.00.0024 Conditional Approval Fee 5036 000.345.81.00.0005 Comprehensive Plan Amend 5909 000.341.60.00.0024 Booklets/EIS/Copies 5941 000.341.50.00.0000 Maps (Taxable) 5954 604.237.00.00.0000 Special Deposits 5955 000.05.519.90.42.1 Postage 5998 000.231.70.00.0000 Tax .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 R<;mai~irrg Balance Due: $0.00