Loading...
HomeMy WebLinkAboutGateway - Elec Legend E1 10.08.9932M V A ML A, k RMODUMT1, Ma Mil lu DETAIL IDENTIFICATION SYMBOL (1 E-1 E-1 M reE"'Mmo- Ta• ,p LIGHT LINE INDICATES NON -ELECTRICAL OR BACKGROUND (THIS IS NOT CONTRACTUAL DEFINITION OF WORK) HEAVY LINE INDICATES NEW WORK (THIS IS NOT CONTRACTUAL DEFINITION OF WORK) DETAIL, DIAGRAM, OR PARTIAL PLAN ALL DETAIL SYMBOLS CONTAIN THE FOLLOWING INFORMATION: SEQUENTIAL CHARACTER (BY SHEET) ALPHABET = SECTIONS & ELEVATIONS NUMBER = DETAILS & PARTIAL PLANS DRAWING CONTAINING SECTION, ELEVATION, PARTIAL PLAN, OR DETAIL DRAWING CONTAINING PLAN AT WHICH SECTION, ELEVATION, PARTIAL PLAN, OR DETAIL APPLIES (NOT ALWAYS USED) FLAG NOTE EXISTING EQUIPMENT AS INDICATED FIXTURE IDENTIFICATION SYMBOL (TYPE A, (2) 32 WATT LAMPS SHOWN) SEE SCHEDULE IN -GRADE FIXTURE POLE LIGHT DUPLEX RECEPTACLE, WEATHERPROOF & GROUND FAULT INTERRUPTING PANELBOARD 208V OR 240V CABINET EQUIPMENT CONNECTION CONCEALED RACEWAY (EXPOSED IN UNFINISHED AREAS) RACEWAY CONCEALED IN OR BELOW FLOOR OR BELOW GRADE -► POWER OR LIGHTING BRANCH CIRCUIT INDICATING CIRCUIT A-11 3,5 HOME RUN TO SOURCE, (HASH MARKS SHOW NO. OF WIRES WHEN MORE THAN TWO REQD, NEUTRAL SHOWN LONGER, DOTS INDICATE ISOLATED GROUND WIRES) 5----- BREAK LINE FOR DRAWING CLARITY RISER DIAGRAM CIRCUIT BREAKER mv� TRANSFORMER, INSULATING PANELBOARD (BRANCH CIRCUIT) OR MOTOR CONTROL CENTER CURRENT TRANSFORMER -3 E— POTENTIAL TRANSFORMER O WATT HOUR METER —o o— MOMENTARY SWITCH: NC, NO �. CONTACT: NC, NO I 15,400 AVAILABLE SHORT CIRCUIT CURRENT, 3 PHASE, SYMMETRICAL (15.400 AMPS SHOWN) d Cp JUNCTION BOX HH HANDHOLE A AMPERE AC ALTERNATING CURRENT ADJ ADJUSTABLE AFF ABOVE FINISHED FLOOR AG ABOVE GRADE AIC AMPS INTERRUPTING CAPACITY AMP AMPERE AVG AVERAGE AWG AM£RICAN WIRE GAUGE BKR BREAKER BLDG BUILDING C COIL or CONDUIT CB CIRCUIT BREAKER CKT CIRCUIT CONC CONCRETE CT CURRENT TRANSFORMER CTL CONTROL Cu COPPER DC DIRECT CURRENT DWG DRAWING DX DELUXE E. EX, EXIST EXISTING ELEC ELECTRICAL EMT ELECTRICAL METALLIC TUBING EQUIP EQUIPMENT FLR FLOOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GFI GROUND FAULT INTERRUPTER GND GROUND HH HANDHOLE HID HIGH INTENSITY DISCHARGE HP HORSEPOWER IES ILLUMINATING ENGINEERING SOCIETY IG ISOLATED GROUND 1MC INTERMEDIATE METAL CONDUIT KCMIL THOUSAND CIRCULAR MILLS KVA KILOVOLT AMPERES KW KILOWATT LT LIGHT LTG LIGHTING MAX MAXIMUM MFR MANUFACTURER MH MANHOLE OR METAL HALIDE MIN MINIMUM r gLO MAIN LUGS ONLY N NEUTRAL NEC "LECTRICAL CODE (NFPA-70) NECA N,�T i ONAL L' w,"STRI CAL CONTRACTORS ASSOCIATION NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NF NON -FUSED NIC NOT IN CONTRACT NTS NOT TO SCALE PC PHOTO -ELECTRIC CELL PF POWER FACTOR PNL PANEL PCV POLYVINYL CHLORIDE PWR POWER OTY QUANTITY RECEPT RECEPTACLE RM ROOM SHT SHEET SPEC SPECIFICATIONS SW SWITCH TYP TYPICAL T/C TIMECLOCK UL UNDERWRITERS LABORATORIES UG UNDERGROUND V VOLTS W WATTS WP WEATHERPROOF ,r W/0 WITHOUT XFMR TRANSFORMER E1 ELECTRICAL LEGEND, ABBREVIATIONS AND DRAWING INDEX E2 ELECTRICAL LIGHTING & POWER LAYOUT E3 ELECTRICAL LIGHTING & POWER LAYOUT E4 ONE-UNE DIAGRAM, SCHEDULES AND DETAILS CITY OF RENTCN DOWNTOWN PARK AND GATEWAY THE BERGER PARTNERSHIP, P.S LANDSCAPE ARCHITECTURE SITE PLANNING 2021 Minor East Seattle, WA 98102 (206) 325-6877 (206)323-6867 Fax A4ABACU5 Engineered Systems 01 Second Ave. So. Suite 201 Seattle, Washin ton 98104 (206)583-0200 Fax((206)583.8826 DRAWN BY OJE CHECKED BY RLV, DLL REVISIONS ® 10/08/99 DATE lP9/99 PROJECT NO. W2914 ELECTRICAL LEGEND, ABBREVIATIONS AND DWG INDEX CC NSTRUCMON SET El