HomeMy WebLinkAboutGateway - Elec Legend E1 10.08.9932M
V A
ML
A, k RMODUMT1, Ma Mil
lu
DETAIL IDENTIFICATION
SYMBOL
(1
E-1 E-1
M
reE"'Mmo-
Ta•
,p
LIGHT LINE INDICATES NON -ELECTRICAL OR BACKGROUND
(THIS IS NOT CONTRACTUAL DEFINITION OF WORK)
HEAVY LINE INDICATES NEW WORK
(THIS IS NOT CONTRACTUAL DEFINITION OF WORK)
DETAIL, DIAGRAM, OR PARTIAL PLAN
ALL DETAIL SYMBOLS CONTAIN THE FOLLOWING INFORMATION:
SEQUENTIAL CHARACTER (BY SHEET)
ALPHABET = SECTIONS & ELEVATIONS
NUMBER = DETAILS & PARTIAL PLANS
DRAWING CONTAINING SECTION, ELEVATION,
PARTIAL PLAN, OR DETAIL
DRAWING CONTAINING PLAN AT WHICH SECTION,
ELEVATION, PARTIAL PLAN, OR DETAIL APPLIES
(NOT ALWAYS USED)
FLAG NOTE
EXISTING EQUIPMENT AS INDICATED
FIXTURE IDENTIFICATION SYMBOL
(TYPE A, (2) 32 WATT LAMPS SHOWN) SEE SCHEDULE
IN -GRADE FIXTURE
POLE LIGHT
DUPLEX RECEPTACLE, WEATHERPROOF &
GROUND FAULT INTERRUPTING
PANELBOARD 208V OR 240V
CABINET
EQUIPMENT CONNECTION
CONCEALED RACEWAY (EXPOSED IN UNFINISHED AREAS)
RACEWAY CONCEALED IN OR BELOW FLOOR OR BELOW GRADE
-► POWER OR LIGHTING BRANCH CIRCUIT INDICATING CIRCUIT
A-11
3,5 HOME RUN TO SOURCE, (HASH MARKS SHOW NO. OF
WIRES WHEN MORE THAN TWO REQD, NEUTRAL SHOWN
LONGER, DOTS INDICATE ISOLATED GROUND WIRES)
5----- BREAK LINE FOR DRAWING CLARITY
RISER DIAGRAM
CIRCUIT BREAKER
mv�
TRANSFORMER, INSULATING
PANELBOARD (BRANCH CIRCUIT)
OR MOTOR CONTROL CENTER
CURRENT TRANSFORMER
-3 E— POTENTIAL TRANSFORMER
O WATT HOUR METER
—o o— MOMENTARY SWITCH: NC, NO
�. CONTACT: NC, NO
I 15,400 AVAILABLE SHORT CIRCUIT CURRENT, 3 PHASE,
SYMMETRICAL (15.400 AMPS SHOWN)
d
Cp JUNCTION BOX
HH HANDHOLE
A
AMPERE
AC
ALTERNATING CURRENT
ADJ
ADJUSTABLE
AFF
ABOVE FINISHED FLOOR
AG
ABOVE GRADE
AIC
AMPS INTERRUPTING CAPACITY
AMP
AMPERE
AVG
AVERAGE
AWG
AM£RICAN WIRE GAUGE
BKR
BREAKER
BLDG
BUILDING
C
COIL or CONDUIT
CB
CIRCUIT BREAKER
CKT
CIRCUIT
CONC
CONCRETE
CT
CURRENT TRANSFORMER
CTL
CONTROL
Cu
COPPER
DC
DIRECT CURRENT
DWG
DRAWING
DX
DELUXE
E. EX,
EXIST
EXISTING
ELEC
ELECTRICAL
EMT
ELECTRICAL METALLIC TUBING
EQUIP
EQUIPMENT
FLR
FLOOR
GFCI
GROUND FAULT CIRCUIT
INTERRUPTER
GFI
GROUND FAULT INTERRUPTER
GND
GROUND
HH
HANDHOLE
HID
HIGH INTENSITY DISCHARGE
HP
HORSEPOWER
IES
ILLUMINATING ENGINEERING SOCIETY
IG
ISOLATED GROUND
1MC
INTERMEDIATE METAL CONDUIT
KCMIL
THOUSAND CIRCULAR MILLS
KVA
KILOVOLT AMPERES
KW
KILOWATT
LT
LIGHT
LTG
LIGHTING
MAX
MAXIMUM
MFR
MANUFACTURER
MH
MANHOLE OR METAL HALIDE
MIN
MINIMUM
r gLO
MAIN LUGS ONLY
N
NEUTRAL
NEC
"LECTRICAL CODE (NFPA-70)
NECA
N,�T i ONAL L' w,"STRI CAL CONTRACTORS
ASSOCIATION
NEMA
NATIONAL ELECTRICAL MANUFACTURERS
ASSOCIATION
NF
NON -FUSED
NIC
NOT IN CONTRACT
NTS
NOT TO SCALE
PC
PHOTO -ELECTRIC CELL
PF
POWER FACTOR
PNL
PANEL
PCV
POLYVINYL CHLORIDE
PWR
POWER
OTY
QUANTITY
RECEPT
RECEPTACLE
RM
ROOM
SHT
SHEET
SPEC
SPECIFICATIONS
SW
SWITCH
TYP
TYPICAL
T/C
TIMECLOCK
UL
UNDERWRITERS LABORATORIES
UG
UNDERGROUND
V
VOLTS
W
WATTS
WP
WEATHERPROOF
,r
W/0
WITHOUT
XFMR TRANSFORMER
E1 ELECTRICAL LEGEND, ABBREVIATIONS AND DRAWING INDEX
E2 ELECTRICAL LIGHTING & POWER LAYOUT
E3 ELECTRICAL LIGHTING & POWER LAYOUT
E4 ONE-UNE DIAGRAM, SCHEDULES AND DETAILS
CITY OF RENTCN
DOWNTOWN PARK AND GATEWAY
THE BERGER
PARTNERSHIP, P.S
LANDSCAPE ARCHITECTURE
SITE PLANNING
2021 Minor East
Seattle, WA 98102
(206) 325-6877
(206)323-6867 Fax
A4ABACU5
Engineered Systems
01 Second Ave. So. Suite 201
Seattle, Washin ton 98104
(206)583-0200 Fax((206)583.8826
DRAWN BY
OJE
CHECKED BY
RLV, DLL
REVISIONS
® 10/08/99
DATE
lP9/99
PROJECT NO.
W2914
ELECTRICAL LEGEND,
ABBREVIATIONS
AND DWG INDEX
CC NSTRUCMON SET
El