Loading...
HomeMy WebLinkAboutR-396210Cfl C'7 I 6 W W rr Q U J Q U W n z O z w rr C) T E 0 co 0 i 0 N 0 0 -o 0 n 3 J n 0 D_ Q ro c N a� m Cn Q C N C 3 0 0 _T C E E 0 0 0 U n CO 0 Lr CD i 0 N i U i 0 0 Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center RIM=408.0 IE=405.50 45 LF 8" PVC 0 1.94% "s. • ,�i 36 LF E" PVC 0 8.97% z1_ 1�0 0 13 70D0275 CB-5, CONCRETE INLET , STA. 2+06.59, 16.74' LT 10' LANDSCAPE BUFFER 470 LF 8'0 STORMWATER DETENTION TANK SEE SHEET SD-01 FOR ADDITIONAL DETAILS 91 LF T PVC 0 2.177o 92-L�-rC� CB-4, TYPE-1 � ne i T . - i , 9 . i^7nTr STA. 1 +22.75, 9.43' LT 11 LF T PVC 0 1.50% SEE PAVEMENT SECTION ON SHEET RD-07 FILTERRA 10'X6' ENHANCED WATER lt7i QUALITY TREATMENT VAULT TA X PA -RC EL 28 LF T PVC 0 1. _ _ ONCREfE-VALLEY GUTTER a F�� 10 D D D 1 — STA. 3+52.74, 9.21 RT HEIGHT CONCRETE CURB a— — F OM STA 2+44 -STA 3+53.I::::::::::::::::::SEE DT-03 10' LANDSCAPE ................. .......... [ZERO FROM STA 3+53 - STA 4+63 �J N ....^ a BUFFER SEE DT-03 \ ...... 35 LF 8" PVC 2.80?� 30�...... r ^ 61 LF�PVCO TRW .. '\ I 07 157 CB-13, TYPE-2-48"� fL .. LL:/..... +1 UTILITY ESMT k RIM=410.35 COTTAGE B PVMT PVMT I 00 RIM=410.40 ,IE=408.25IE=404.14 :...:: ;.PE-2-48" - STA. 11 +43.01 47.61' ` .. MEECB-10, RIM=410.30 -.'. CB-9, TYPE-1 nL OCKING LID IE=403.68;;,_; ', IE=408.50 W/ SOLID LOCKING LID I .::.....: .::: = I 8. 20P i•'%nr: � �� ..a'=, :...:: .;. IE=408.50 . CTA 111nr,'n G7 CGS I TI I ,a_j ........ I ;._._. .... If .. ...... I....'.,_,_. .:N ....... NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON HOUSE / ( U) a I CB-15 TYPE-2-48"O CB-6, CONCRETE INLET is ' Lj W SOLID LOCKING LID Q C13-7, TYPE 1 STA. 2+43.95, 9.54 RT TAX PARCEL ,+A. S -,-r 9.2S' P+ STA. 4+14 03 814' RT � 115' 1 4 15 thANNIVERCA1?y Surveying Engineering LDCIPlanning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 www.LDCcorp.com SCALE: 1" = 20' 20' 0 20' 40' LEGEND o STORM PIPE ------------ DRAIN PIPE ROOFLINE SEWER PIPE WATER PIPE ® DOWNSPOUT O STORM DETENTIOM CLEAN OUT O YARD DRAIN STOP SIGN PERVIOUS PAVEMENT PROPOSED ASPHALT PROPOSED GRIND/OVERLAY i- UTILITY CROSSING NOTES 1. ALL ROOF DRAIN PIPE IS 6" 0 AT 2.0% MIN SLOPE UNLESS OTHERWISE SPECIFIED. 2. SEE SHEET RD-02-RD-06 FOR ROAD AND STORM DRAINAGE PROFILES. 3. SEE SHEET SD-01 FOR STORM DRAINAGE DETENTION PIPE DETAILS. PIPE CROSSING TABLE STA 1 +23.22, 22.00' RT. (DRIVE A) 1 8" PVC PIPE BOTTOM=400.88 12" SS TOP=399.01 PIPE SEPARATION=1.87' STA 1 +23.22, 30.40' RT. (DRIVE A) 2 8" PVC PIPE BOTTOM=403.75 8" WATER TOP=402.25 PIPE SEPARATION=1.50' STA 16+98.98, 17.11' LT. (SE 172ND ST) 3 12" PVC PIPE=391.64 8" SS TOP=389.22 PIPE SEPARATION=2.42' STA 1 +23.22, 1.48' LT. (DRIVE A) 4 8" PVC PIPE=400.52 8' DETENTION PIPE TOP=399.00 PIPE SEPARATION=1.52' STA 2+10.17, 10.21' LT. (DRIVE A) 5 8" PVC PIPE=402.42 8' DETENTION PIPE TOP=399.00 PIPE SEPARATION=3.42' co 00 N O CD T co O O O O T Q J F5 H H 1 \ ._I -' / �� \�, IN COMPLIANCE WITH CITY OF RENTON STANDARDS Lull A S-B UIL T DRAWINGS TOPOGRAPHIC DISCLAIMER TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER. 0 AS —BUILT DRAWINGS MEV 12-13flAP SURVEYED: LDC SCALE: DESIGNED: MEV 1 -20' HM W IN3i1991 uR % C TY OF RENTON SPECIAL CARE COMMUNITY, LLC RENTON RENTON SPECIAL CARE COMMUNITY DRAWN: NC 17033 108TH AVE SE, RENTON, WA 98055 ONE INCH DATU M CHECKED: MEV AT FULL SCALE Plan ning/Building/Public Works Dept. ROAD AND STORM DR�4/NAGEPLAN IF NOT ONE INCH NO. REVISION BY DATAPPROVED: MEV SCALE ACCORDINGLY R-396210 U Q W DAM 04-08-17 flElDB00K: O PAGE: DRAWING NO: RD-01 Z SHEET. 0F. 10 23