Loading...
HomeMy WebLinkAboutR-396212NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHINGTON N (0 C'7 O 0 W W rr LU U Q U n z O z W rr N T o, 3 q n I 0 o' I Q 0 m I Q i 0 0 _T C E E 0 0 0 0 U Q 0 o' QD i 0 N i i EL C 0 0 Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center N 0 Q N 420 ��oN z orn U p0 U J + c+0 O � w LLI F_ Z V) N L J UJ 400 0 wl ZI J I I O I U7 CV M + C 06 O Co M I II N LJLLJ a a 5.022% 56 L.F. if SD 0 2.07% -7 1 r 9 n" c- n 4 7 Pf I C13-2, TYPE 2-54" CONTROL STRUCTURE J80 C13-1, TYPE 2-49 . SEE SE 172ND ST PROFILE, 6S SHEET RD-02 STA 0+73.64, 1.88' LT - . RIM=400.77 zn- cn IE=392.00 8"0) W - � - - - - IE=391.49 �lfO) N IE=391.36 1 f O S - 12 L.F. T PVC 0 31.96% C1373, ITYPE 1 W/ SOLID LICKING LID J60 STA 0+73.32, 13.40' LT . RIM=400.63 SS- IE=395.69 (TO) N,E - I THE PROFILE VIEW CALLS VV I so ■V� / ■ CROSSING # 1 STA. 1 +23.31, 21.98' RT. 12" SD IE=400.88 8" SS CROWN=399.01 SEPARATION=1.87' CDZ FINISHED GRADE CDM AT DRIVE AISLE J EXISTING GRADE w AT DRIVE AISLE 1 a 5.49%_ 0 WO DETENTION PIPE INLET-1 STA. 1 +27.14, 4.5 LT RIM--4e3-48- rdM=403.37 £8--48CB-10A, TYPE 2-48" W/ SOLID LOCKING LID ' STA 1 +31.38, 20.56' R RIM-484.86- RIM=405.11 - IE=391.57 (WO) N - IE=402.01 (8 O) E CB-4, TYPE 1 I S+A. 1 ,-- �, ' - STA 1 +22.75, 9.43' LT 3.19S RIM=403.02 IE=400.37 (TO) N,E,S 96" 0 DETENTION PIPE THE CONNECT ON FRC IM THE TANK TO THE OUT ET CONTROL STRUCTURE SHOULD BE 3 -IN MINI AUM PER ECTIO 5. 1 . . 1 OF TH SWD . WA THIS CHA GED T 12-1 OR IS TH S AN ERROR? 28 L.F. 8" PVC 0 1.80% 0 36 LF 6' PVC REFERENCE LINE SEE SHEET RD-04 0 o rn OIR r� ffj + + + O Q QJ C:) J V) Lj Lil (n Ed 3.33% 4.44% z � 91 LF g PVC 2.17% n I !' Ono r o rn r i o o F� C13-8, TYPE 2-48" STA. 1 +23.22, 41.27' RT. SEE COURT YARD, RP-06 INLET-2 STA. 1 +77.43, 5.5 R1 p4li- i es. is RIM=405.39 INLET-3 STA. 1 +77.47 15.5 RT R{#-;- MM=405.48 INLET-4 STA. 1 +87.14, 4.5 LT -- oRill! 186.68 RIM=405.51 MODULAR WETLAND OUTFALL MODULAR WETLAND INTAKE STA 1 +01.07, 13.59' LT . RIM=402.81 RIM---492.S RIM- CB-5, CONCRETE INLET J40 IE=396.18 (TO) S +E-�9 S - STA 2+06.59, 16.74' LT . STA 1+11.93, 11.50' LT RIM=405.76 6-9gr RIM=402.81 IE=402.42 EDRIVEA IE=400.21 (TO) INIE=402.35 �15'0�6'0S `F EXISTING GRADE FINISHED GRADE AT DRIVE AISLE AT DRIVE AISLE Z SCALE: HOR: 1"=20' VER: 1" =10' 3§ LF. 4" PVC ® 8. 7% O O O O O o O o O 0+00 0+50 15 thANNIVERCA1)y Surveying Engineering LDCIPlanning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 www.LDCcorp.com WX 0 O, J80 Z 4 o W i v� Z~ N J60 ■ ■ ■ IJ40 ■ THIS IS NOTED AS 6-IN IN PLAN VIEW FOR TRASH INCLOSURE ROOF DRAIN -20' CITY EMERGENCY ACCESS ESMT 45 LF T PVC P'j --1 -rt I I SCALE: 1" = 20' (le) CID 20' 0 20' 40' N O O r NOTE T SEE SHEETS DT-01 THROUGH DT-03 FOR STORM DRAINAGE 0 NOTES AND DETAILS. I I LEGEND STORM PIPE SEWER PIPE WATER PIPE � CHECK DAM, SEE DETAIL SHEET DT-01 TOPOGRAPHIC DISCLAIMER I TOPOGRAPHIC SURVEY INFORMATION CONTAINED ON THESE PLANS HAS BEEN PROVIDED BY CORNERSTONE ENGINEERING, INC. LDC, INC. (LAND 1+00 1+50 2+00 DEVELOPMENT CONSULTANTS, INC.) ASSUMES NO LIABILITY AS TO THE ACCURACY AND COMPLETENESS OF THIS DATA. ANY DISCREPANCIES FOUND BETWEEN WHAT IS SHOWN ON THE PLANS AND WHAT IS NOTED IN THE FIELD SHOULD BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER. 0 AS -BUILT DRAWINGS MEV 12-13-18 SURVEYED: LDC SCALE: HORIZONTAL HAD ;N3719,1 C T Y 0 E DESIGNED: AS NOTED DRAWN: MEV RENTON NC ONE INCH DATUM CHECKED: MEV AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH NO. REVISION BY DATE APPR APPROVED: MEV SCALE ACCORDINGLY PERVIOUS PAVEMENT N O PROPOSED ASPHALT OO PROPOSED GRIND/OVERLAY I CD AS-BOIL T DRA WINGS T Q J u� H n i N COMPLIANCE WITH CITY OF RENTON STANDARDS W RENTON SPECIAL CARE COMMUNITY, LLC RENTON SPECIAL CARE COMMUNITY 17033 108TH AVE SE, RENTON, WA 98055 ROAD AND STORM DRAINAGE PROFILES R-396212 U Q W DAM 04-08-17 flElDB00K: O PAGE: DRAWING NO: RD-03 Z sl+EEr: 2 123