Loading...
HomeMy WebLinkAboutR-396219NE 1/4 OF THE SW 1/4 AND SE 1/4 OF THE NW 1/4, SEC 29, TWN 23, RGE 5 E, KING COUNTY, WASHING TON N (C) O C'7 I 0 w W rr Q U U w �n V ) Z 0 Z W rr E 0 DO 0 I 0 N r7 U 0 0 -o 0 0 n Type 1 Curb Inlet Top Inlet Top Reinforcing ASTM / WSDOT requirements • All components #4 grade 60 reinforcing Inlet Top Conformity Standards Washington State APWA / WSDOT Standard Specifications WSDOT B-5.20.-01 Designed for a Type I, 1-L, or 1-P Inlet Top Components 24" Cast Iron Locking Frame & Cover w/ 2 %" x 3 %" x %" x 35 7/8" Galvanized Angle Iron 2 ea. #4 Trash Bars at 9" OC • 2" lift holes Weight 550 Ibs w/casting Type I Catch Basin [please see pg. 75, Type I Catch Basin for more details] 32" Catch Basins 0 Side View --------- STORM �v.Y.y w, `�� vVVC7 5" 8" Note: Drawings are not to scale. This is not a specialized "Shop Drawing." Designed for submittal purposes only. Sj' )^ Shope Enterprises, Inc. (253) 848-1551 1-800-422-7560 [Toll Free] 1 ' �IJ��/ 1618 East Main Avenue Fax Line 1 (253) 845-0292 www.shopeconcrete.mm concrete products Puyallup, WA 98372-3142 Fax Line 2 (253) 864-6172 NOTES 1. CHECK DAM OR INTERCEPTOR REQUIRED FOR LONGITUDINAL SLOPES > 2%. 2. SPACE CHECK DAMS BASED ON SLOPE TO ACHIEVE DESIGN AVERAGE PONDING DEPTH BEFORE OVERTOPPING DAM. 3. CALCULATE STORAGE VOLUME BETWEEN CHECK DAMS BASED ON CHECK DAM HEIGHT AND SLOPE FOR MODELING. 4. LONGITUDINAL SLOPE MAXIMUM VARIES WITH WEARING COURSE MATERIAL PER STANDARD DETAIL NDT-11 AND NDP-12. //\ COMPACTED SUBGRADE OR BASE Call 2 Business Days Before You Dig 811 or 1-800-424-5555 Utilities Underground Location Center 8" rluP-ru nAKA CPArINIC VARIP-C PLAN VIEW o� a0 F_ ZO oFW z0� z �a� 'WW 'v W (V a oZ ZZ 7 O SECTION A -A SDR 35 INLET COUPLING CAST INTO PRECAST VAULT WALL am 0 INLET COUPLING LOCATIONS TREE GRATE CLEAN OUT FRAME AND COVER CAST INTO TOP SLAB ENERGY DISSIPATION ROCKS SDR 35 INLET PIPE WITH BYPASS SLOTS SDR 35 INLET COUPLING FIE=400.11 �II o� � a0 L_ °� s z go LU q aL WW > N ?Z Z z O 6" UNDERDRAIN STONE LAYER, TYP. PROVIDED BY CONTECH 6" BYPASS INLET PIPE CONFIGURATION APPROXIMATE MAXIMUM BYPASS = 0.6 CFS DESIGNATION SIZE LENGTH WIDTH INLET/ OUTLET PIPE DIA. P UNDER- DRAIN PIPE DIA. (PERF.) TREE GRATE QTY. & SIZE FTIBP0404-6 4 x 4 4'-0' 4'-0" 6' SDR 35 4" SDR 35 (1) Tx 3' FTIBP0604-6 6 x 4 6'-0" 1 4'-0" 6' SDR 35 4" SDR 35 (1) Tx 3' FTIBPO606.6 6 x 6 6'-0" V-0" 6' SDR 35 4" SDR 35 (1) Tx 3' FTIBP0804-6 8 x 4 8'-0' 4'-0" 6' SDR 35 4" SDR 35 (1) Tx 3' FTIBP0806-6 8 x 6 8'-0' 6'-0" 6' SDR 35 4" SDR 35 (1) 4' x 4' FTIBP1006-6 10x6 10'-0" 6'-0" 6'SDR35 6"SDR 35 (1)4'x4' FTIBP1204-6 12 x 4 12'-0" 4'-0" 6- SDR 35 6" SDR 35 (2) Tx 3' FTIBP1206-6 12 x 6 12' -0" 6'-0" 6' SDR 35 6" SDR 35 (2) 4' x 4' FTIBP1307-6 13 x 7 13'-0" 7'-0" 6' SDR 35 6" SDR35 (2) 4' x 4' INTERNAL PIPING MAY VARY DEPENDING UPON INFLUENT LOCATION ' MAXIMUM TOP TO INVERT OUT = 5'-5' " MAXIMUM TOP TO INVERT IN = 2'-6" 6" PERVIOUS PAVEMENT WEARING COURSE 2" LEVELING COURSE 24" RESERVOIR COURSE 6" RUNOFF TREATMENT COURSE �j COMPACTED SUBGRADE OR BASE -CHECK DAM, NON -PERMEABLE MATERIAL 1' WIDE TYP. DAM TO EXTEND INTO NATIVE MATERIAL 1' ON EACH 6" SIDE, AND 6" EMBEDMENT. SLOTTED DRAIN PVC PER ASTM D1785 SCH 40 6" MIN SEPARATION BETWEEN BOTTOM OF CHECK DAM AND TOP OF WATER OR STORM PIPES PERVIOUS PAVEMENT CHECK DAM DETAIL SCALE: NTS 1 thANNIlir-QcADV Surveying 5 LDC1 Engineering Planning 20210 142nd Avenue NE Ph. 425.806.1869 Woodinville, WA 98072 Fx. 425.482.2893 www.LDCcorp.com INI=11/YAO"Al A SDR 35 OUTLET COUPLING CAST INTO PRECAST VAULT WALL - PLANT PROVIDED BY CONTECH TREE GRATE AND FRAME CAST INTO TOP SLAB TOP SLAB 3" MULCH LAYER, TYP. PROVIDED BY CONTECH 02" IRRIGATION PORT. TYP. H 0 3 O m a. ~� Z Z O IE-397.20 �> ° " ' M ��W q 1qz alr V 7 V 1 21" FILTERRA MEDIA, TYP. 4",YPASSfUNDERDRAIN PROVIDED BY CONTECH O SDR 35 OUTLET COUPLING I FLOWKIT PROVIDED BY CONTECH 8" BYPASS INLET PIPE CONFIGURATION APPROXIMATE MAXIMUM BYPASS = 1.2 CFS UNDER- INLET/ TREE DRAIN DESIGNATION SIZE LENGTH WIDTH OUTLET GRATE PIPE DIA. PIPE DIA. (PERF.) CITY. & SIZE FTIBP0804 x 4 6' 4' 8" SDR 35 4" SDR 35 (1) 3' x 3' FTIBPOBD6 6'A X.SDR FTIBP080 8 -0" 0" 8"a-6 D 35 4" R (1) x FTIBPO806-6 x 8" SDR 35 8" SDR 35 I 4" SDR 3 I 6" SDR 35 ) 4' FTIBP1006-8 10 x 6 10'-0" 6'-0" 1 4' x 4' FTIBP1204-8 8" SDR 35 6" SDR 35 1 4 2' 4'- ' ( ' FTIBP1206-8 2 '-0" -0" 8" SDR 35 " SDR 35 (2) x ' FTIBP1307-6 x 1 -0" 7' 8" SDR "s5 SDR 3 ) 4' 4' INTERNAL PIPING MAY VARY DEPENDING UPON INFLUENT LOCATION * MAXIMUM TOP TO INVERT OUT = 6-5" xM"N V ** MAXIMUM TOP TO INVERT IN = 2'-6" * DIMENSIONS MAY VARY t r" DEPENDING f i lre «a ON PRECASTER BUILD CONFIGURATION. �,A"m,.,�M. "Eu,E"��"" E 92F 800 0 1 AS -BUILT DRAWINGS NO. REVISION MEV 12-13-18 SURVEYED: LDC DESIGNED: MEV DRAWN: NC CHECKED: MEV BY DATE APPR APPROVED: MEV D PLAN VIEW SECTION A -A I I A I I I 1i- _J 10" BYPASS INLET PIPE CONFIGURATION APPROXIMATE MAXIMUM BYPASS = 2.2 CFS UNDER- INLET/ DRAIN TREE DESIGNATION SIZE LENGTH WIDTH OUTLET GRATE PIPE DIA. PIPE DIA. (PERF.) CITY. & SIZE FTIBP0606-10 6 x 6 6'-O" 6'-O" 10" SDR 35 4" SDR 35 (1) Tx 3' FTIBP0806-10 8x6 8'-0" 6'-0" 10"SDR35 4"SDR35 (1)4'x4' FTIBP1006-10 10 x 6 10'-0" V-0" 10" SDR 35 6" SDR 35 (1) 4' x 4' FTIBP1204-10 12 x4 17-0" 4'-0' 10" SDR 35 6" SDR 35 (2) 3' x 3' FTIBP1206-10 12 x 6 12'-0" 6'-O" 10" SDR 35 6" SDR 35 (2) 4' x 4' FTIBP1307-10 13 x 7 I T-O" 7'-O" 10" SDR 35 6" SDR 35 (2) 4' x 4' INTERNAL PIPING MAY VARY DEPENDING UPON INFLUENT LOCATION ' MAXIMUM TOP TO INVERT OUT = 5'-5" " MAXIMUM TOP TO INVERT IN = Z-6" SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAW IN$ HORIZONTAL NAO 1983/1991 DATU M C TY OF RENTON • Plan ning/Building/Public Works Dept. SURFACE WATER DRAINAGE NOTES AND SPECIFICATIONS 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRECONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF RENTON PLAN REVIEWER. 2. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE 1996 STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA), AS AMENDED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. 3. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS, WHICH ARE ON FILE IN THE PUBLIC WORKS DEPARTMENT. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. 4. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 5. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 METERS, AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 METERS UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 6. ALL SEDIMENTATION/EROSION FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING AND BUILDING CONSTRUCTION, AND THEY MUST BE SATISFACTORILY MAINTAINED UNTIL CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ON -SITE EROSION HAS PASSED. 7. ALL RETENTION/DETENTION FACILITIES MUST BE INSTALLED AND IN OPERATION PRIOR TO OR IN CONJUNCTION WITH ALL CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. 8. GRASS SEED MAY BE APPLIED BY HYDROSEEDING. THE GRASS SEED MIXTURE, OTHER THAN CITY OF RENTON APPROVED STANDARD MIXES, SHALL BE SUBMITTED BY A LANDSCAPE ARCHITECT AND APPROVED BY THE PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. 9. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH SECTION 7-02.3(1) OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING SHALL BE APWA CLASS " C", WITH THE EXCEPTION OF PVC PIPE. ALL TRENCH BACKFILL SHALL BE COMPACTED TO MINIMUM 95% FOR PAVEMENT AND STRUCTURAL FILL AND 90% OTHERWISE PER ASTM D-1557-70. PEA GRAVEL BEDDING SHALL BE 6 INCHES OVER AND UNDER PVC PIPE. 10. GALVANIZED STEEL PIPE AND ALUMINIZED STEEL PIPE FOR ALL DRAINAGE FACILITIES SHALL HAVE ASPHALT TREATMENT # 1 OR BETTER INSIDE AND OUTSIDE. 11. STRUCTURES SHALL NOT BE PERMITTED WITHIN 10 FEET OF THE SPRING LINE OF ANY STORM DRAINAGE PIPE, OR 15 FEET FROM THE TOP OF ANY CHANNEL BANK. 12. ALL CATCH BASIN GRATES SHALL BE DEPRESSED 0.10 FEET BELOW PAVEMENT LEVEL. 13. OPEN CUT ROAD CROSSINGS THROUGH EXISTING PUBLIC RIGHT OF WAY WILL NOT BE ALLOWED UNLESS SPECIFICALLY APPROVED BY CITY OF RENTON PLANNING/ BUILDING/ PUBLIC WORKS ADMINISTRATOR. 14. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A DEPTH OF ONE (1) FOOT AND MUST MEET THE FOLLOWING SPECIFICATIONS: 4 - 8 INCH ROCK / 40 - 70% PASSING; 2 - 4 INCH ROCK / 30 - 40% PASSING; AND LESS THAN 2 INCH ROCK / 10 - 20% PASSING. 15. ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS APPROVED BY THE CITY PLAN REVIEWER OR SURFACE WATER UTILITY SECTION. AN ACCURATELY DIMENSIONED, CERTIFIED AS -BUILT DRAWING OF THIS DRAINAGE SYSTEM WILL BE SUBMITTED TO THE CITY UPON COMPLETION. 16. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY OF RENTON DOES NOT RELIEVE THE OWNER OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED WITH STORM SURFACE WATER DISPOSITION. FURTHER, THE CITY OF RENTON DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE SYSTEM PROVIDED DURING CONSTRUCTION. 17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACT. ANY WORK WITHIN THE TRAVELED RIGHT OF WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVE BY THE PUBLIC WORKS DEPARTMENT, TRANSPORTATION SYSTEMS DIVISION. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-07-23 TRAFFIC CONTROL SHALL APPLY. 18. SPECIAL DRAINAGE MEASURES WILL BE REQUIRED IF THE PROJECT LOCATION IS WITHIN THE AQUIFER PROTECTION AREA (APA). A S-B UIL T DfMWINGS C'7 00 (D N O O T co O O O I T Q J N COMPLIANCE WITH CITY OF RENTON STANDARDS W RENTON SPECIAL CARE COMMUNITY, LLC RENTON SPECIAL CARE COMMUNITY 17033 108THAVE SE, RENTON, WA 98055 NOTES AND DETAILS R-396219 OC U Q W DATE: OV l FIELD0.- O 8 - 17 PAGE: O DRAWING NO: R DT- 01 Z SHEEP: 19F: 23