HomeMy WebLinkAboutLUA14-000869_Report 1DEPARTMENT OF CO /IUNITY
AND ECONOMIC DEVELOPMENT
MODIFICATION OF RESIDENTIAL DESIGN REQUIREMENTS FOR
PROJECTS WITHIN THE R-4 AND R-8 ZONES
[g] APPROVAL D DENIAL
EVALUATION FORM & DECISION
An "X" is shown in the applicable residential design requirement box. When an alternative is
employed that requires a modification, the staff evaluation is written on the lines below. The
decision to approve or deny the requested modification can be found at the conclusion of this
form.
PROJECT NAME:
PROJECT NUMBER:
PROJECT MANAGER:
APPLICANT:
Piper's Bluff Plan 4024A Residential Design Modification
LUA14-000869, MOD
Angelea Wickstrom, Assistant Planner
Kim Hall
846 108th Ave NE
Bellevue, WA 98004
ZONING DESIGNATION: Residential -8 dwelling units per acre (R-8)
PROJECT LOCATION: 5203 and 5105 NE 12th St, 5106 NE 11th Pl, and 1166 Hoquiam Ave NE
SUMMARY OF REQUEST: The applicant is requesting approval of a modification of the
Residential Design Standards (RMC 4-2-115) on a proposed Elevation
Plan 4024A for Piper's Bluff Plat. The proposed project site is within
the Residential -8 (R-8) dwelling units per acre zoning classification,
and is located on the east side of Hoquiam Ave NE, north of and in the
vicinity of NE 11th Ct, and south of Sunset Blvd, all in Sect. 10, Twp
23N Rng 5 E. Plan 4024A will be used for lot 13 of phase 1 of this
project and could be used in phase 2, however the location has not yet
been determined. This modification would be applicable to all home
models, 4024A, that are constructed on any lot within the Piper's Bluff
subdivision (LUA12-076).
1. Roof
Choose one:
D Hip or gabled with at least 6:12 pitch; or
D Shed roof; or
City of Renton Department of Co nity and Economic Development Administrativ odification Request Report & Decision
Piper's Bluff Plan 4024A Residential Design Modification LUA14-000S69, MOD
Report of July 10, 2014 Page 2 of 4
~ Alternative that meets guidelines (Explain): The applicant is requesting approval of a
lower roof pitch than the minimum standard of 6:12. The roof on this plan is a hip
roof with a roof pitch set at 3:12 to meet the intended modern architectural style,
which typically includes low roof lines. The applicant asserts, and staff agree, that
"the use of multiple rooflines and types creates great interest even with a lower
pitch". A variety of roof forms will be used in the Piper's Bluff Plat. To ensure that
the subdivision has a variety, staff recommends as a condition of approval that a
variety of roof pitches are used throughout the subdivision, and that identical home
styles are not placed abutting each other within the subdivision.
And if more than nine (9) lots choose one:
~
D
A variety of roof forms are used; or
Alternative that meets guidelines (Explain) N/A
2. Architectural Detailing
Choose one:
D Trim (minimum of 3 -1/2") around all windows and doors; or
D Shutters on windows and trim (minimum 3 -1/2") around doors; or
~ Alternative that meets guidelines (Explain): The applicant proposes to use a window
and door trim lower than the standard of 3-1/2 inches. The applicant states that
"this plan uses several different siding types for an interesting 'texture' over the
front facade. In addition, three color paint schemes greatly enhance the variety of
textures to provide a very high quality product." The applicant asserts, and staff
agree, that these dramatic, architectural features eliminate the need for additional
architectural detailing.
And, if one siding material is used on any side that is 2 stories or more, choose one:
D A horizontal band (minimum 8") is used between the first and second story; or
~ Alternative that meets guidelines.
3. Garages
Choose one:
D Recessed 8' from the front of the house and/or front porch; or
D Roof extends 5' beyond garage front at least the width of the garage and the
porch/stoop; or
D Alley Accessed; or
D Located so that the entry does not face a street or an access easement; or
D Sized so it represent no greater than 50% ofthe front fa~ade width at ground level; or
City of Renton Department of Co nity and Economic Development Administrativ_ .-odification Request Report & Decision
Piper's Bluff Plan 4024A Residential Design Modification LUA14-000869, MOD
Report of July 10, 2014 Page 3 of 4
D Detached; or
[:gJ Alternative that meets guidelines (Explain) The garage doors of this plan are recessed
2' -4" under the front facade to minimize the impact on the front elevation. The
applicant states, and staff concur, that "the use of additional glazing in the doors
further reduces the impact and enhances the architectural style of the home."
And, if the garage is wider than 26', choose one:
[:g) The portion greater than 26' is setback at least 2'; or
D Alternative that meets guidelines (Explain) N/A
RMC 4-9-2500.2 Criteria for Modification of the Standards.
The requested modification must also meet the following criteria:
1. Will meet the objectives and safety, function, appearance, environmental protection and
maintainability intended by the Code requirements, based upon sound engineering
judgment; and
2. Will not be injurious to other property(ies) in the vicinity; and
3. Conform to the intent and purpose of the Code; and
4. Can be shown to be justified and required for the use and situation intended; and
5. Will not create adverse impacts to other property(ies) in the vicinity.
DECISION
The proposal satisfies 5 of the 5 criteria listed in RMC 4-9-250D2 for approval of modifications.
Therefore, the Piper's Bluff Plan 4024A Residential Design Modification of the residential
design standards for the proposed single-family residential structure, Project Number LUA14-
000869, MOD is approved subject to one condition of approval.
CONDITIONS
1. A variety of home types shall be used throughout the Piper's Bluff subdivision. No identical
home styles shall be placed on abutting lots.
7/10/2014
Jennifer Henning, Planning Director Date
Department of Community & Economic Development
City of Renton Department of Co nity and Economic Development Administrativ .odification Request Report & Decision
Piper's Bluff Plan 4024A Residential Design Modification LUA14-000869, MOD
Report of July 10, 2014 Page 4 of 4
The decision to approve the modification(s) will become final if not appealed in writing together
with the required fee to: Hearing Examiner, City of Renton, 1055 South Grady Way, Renton,
WA 98057 on or before 5:00 pm, on July 24, 2014. Additional information regarding the appeal
process may be obtained from the Renton City Clerk's office, Renton City Hall -7'h Floor, (425)
430-6510.
If you have any further questions regarding this decision, feel free to contact the project
manager, Angelea Wickstrom, at 425.430.7312 or awickstrom@rentonwa.gov.
6/20/2014
Angelea Wickstrom
Planning Specialist, City of Renton
1055 South Grady Way
Renton, WA 98057
RE: Modification to Residential Design Standards, Pipers Bluff-Plan #4024A
Dear Angele a,
EXHIBIT 1
Please consider this letter our formal request for a plan modification approval of plan# 4024A, which will be
used on lot 13, phase 1 (phase 2 matrix T.B.D.). We feel the plan meets the intent of the residential design
guideline due to the dramatic, architectural features which greatly minimize the impact of the garage on the front
fa,ade and eliminate the need for additional architectural detailing as noted in the permit comments. The
significant building modulation, multiple roof lines, and variety of siding materials reflect a high quality product
that will bring value to the city of Renton.
Specifically:
1) Garage -the garage doors of this plan are recessed 2' 4" under the front fa,ade to minimize the impact on
the front elevation. The use of additional glazing in the doors further reduces the impact and enhances
the architectural style of the home.
2) Roof -the roof of this plan is a combination shed/ hip roof with the pitch set at 3 : 12 to meet the
intended modern architectural style, which typically includes low roof lines. The use of multiple rooflines
and types creates great interest even with a lower pitch.
3) Architectural Detailing-this plan uses several different siding types for an interesting "texture" over the
front fa,ade. In addition, 3 color paint schemes greatly enhance the variety of textures to provide a very
high quality product.
This plan represents one of four plan types to be offered, with two to three elevations each for a total of 10
unique front elevations, several of which will be offered as "reverse" plans. All are of similar style and quality. The
total product count is 28 units, so there is a broad plan mix to avoid using a like plan next to another.
The first two plans have been previously approved under permit numbers B13006240 and Bl3005935 and are
currently under construction. Under review at this time are permit applications B14002077 and 814002076. I have
included the overall and individual site plans, and elevations as directed, in addition to a copy of the Plan Review
Comments for each. Please let me know if you require any further information.
I look forward to your response.
Thank you,
Kim Hall
Project Manager
425-646-4421
kimh@connerhomes.com
Milbrandt Architects
PIPER'S BLUFF ELEVATION CONCEPT A
2-CAR BASEMENT PLAN (•loz•t)
,/
leptember 24,
m >< :::c
t-1 m
t-1
-4
11,J
dYN >JlNl:llA aNV J.33HS ~
.::l.::lffl8 S,l:l3dlc
S3V\IOH 83NNO:J
'
EXHIBIT 3
b
0
! ' . ' ' ! I ' •
; 0 ' l
' ! ' ~ 'Ii 5 ~
RECEIPT EG00025320
BILLING CONTACT
CONNER HOMES AT PIPERS BLUF
846 108TH AVE NE
BELLEVUE, WA 98004
REFERENCE NUMBER FEE NAME
LUA 14-000869 PLAN -Modification
Technology Fee
Printed On: 7/10/2014 Prepared By: Angelea Wickstrom
'
TRANSACTION
TYPE
Fee Payment
Fee Payment
Transaction Date: July 03, 2014
PAYMENT
METHOD
lcheck#312
lcheck #312
SUB TOTAL
TOTAL
AMOUNT PAID
S100.00
$3.00
$103.00
$103.00
Page 1 of 1