HomeMy WebLinkAboutLUA16-000439_Report 1DEPARTMENT OF ~vMMUNITY
AND ECONOMIC DEVELOPMENT -------Renton®
MODIFICATION OF RESIDENTIAL DESIGN REQUIREMENTS FOR
PROJECTS WITHIN THE R-4, R-6, R-8, R-10, AND R-14 ZONES
APPLICATION FORM & DECISION
Applicant Name:
Mike Woodbridge
Applicant Mailing Address:
5603 SE 2"' Ct
Planning Division
1055 South Grady Way-Renton, WA 98057
Phone: 425-430-7200 Fax: 425-430-7231
APPLICANT CONTACT INFORMATION
Company (if applicable):
Exceptional NW Homes LLC
Phone Number:
425-235-2841
City:
Renton
PROJECT INFORMATION
Project Name: Shelden Short Plat Lot 4 Residential
Design Modification
I Parcel Number:
' 334390-2564
Project Location:
1820 NE 13th St
Email:
mike@realestate-
wa.com
State/ Zip:
WA98059
Zoning Designation:
R-8
Summary of Request: Applicant is requesting a Residential Design Modification for a 4:12 roof pitch on the
proposed lot 4 home within Shelden Short Plat, rather than a 6:12 roof pitch which is required by vested code.
Current code permits a 4:12 roof pitch.
Please explain how your project proposal meets the "guidelines» for each design.~errien~/ra~~~~{li~n the
standards.
Code Section: 4-2-115E.3. "Roofs" Compliance with Guidelines:
Guidelines:
Roofs shall represent a variety of forms and profiles
that add character and relief to the landscape of the
neighborhood. The use of bright colors, as well as
roofing that is made of material like gravel and/or a
reflective material, is discouraged.
We are proposing to use a 4:12 roof pitch in order to
best compliment the modern style of the home. The
traditional 6:12 roof does not match the integrity of
this style.
In addition to this form, the following attachments are required:
• Site plan and elevations.(8.Sxll size)
• Built example photos (if available)
Criteria for Modification of the Residential Design Standards
Renton Municipal Code, section 4-2-115, lists elements that are required to be included in all residential
development in the zones stated in subsection B of this Section. Each element includes both standards and
guidelines. Standards are provided for predictability. These standards specify a prescriptive manner in which the
requirement can be met. Guidelines for each element are provided for flexibility. These guidelines provide
direction for those who seek to meet the required element in a manner that is different from the standards.
a. The determination as to the satisfaction of the requirement through the use of the guidelines is to be
made by the Community and Economic Development Administrator when no other permit or
approval requires Hearing Examiner review.
b. When it has been determined that the proposed manner of meeting the design requirement through
guidelines is sufficient, the applicant shall have satisfied that design requirement.
I, the undersigned, declare under penalty of perjury under the laws of the State of Washington, that to the best of
my knowledge the above information is true and complete.
/ __ ltJ.-16 Date: ___ t> __ " ______ _
DEPARTMENT OF Cu,JIMUNITY
AND ECONOMIC DEVELOPMENT --------Renton®
For City Use Only
Project Number: LUA16-000439
DECISION:
Staff agrees with the applicant's justification for Modification of Residential Design Requirements. The proposal
satisfies the criteria listed in RMC 4-2-115A2 for approval of residential design modifications. Therefore, the
Shelden Short Plat lot 4 Residential Design Modification of the residential design requirements for the proposed
single-family residential structure, Project Number LUA16-000439, MOD is approved.
[8J Modification Granted D Modification Partially Granted D Modification Denied
(See attached staff comments)
Jen~,~gg=
June 14, 2016
Date
Department of Community & Economic Development
Conditions of Approval:
Not Applicable
The decision to approve the modification(s) will become final if not appealed in writing together with the required
fee to: Hearing Examiner, City of Renton, 1055 South Grady Way, Renton, WA 98057 on or before 5:00 pm, on June
28, 2016. Additional information regarding the appeal process may be obtained from the Renton City Clerk's office,
Renton City Hall -7th Floor, (425) 430-6510.
This decision expressly approves the specific request(s) to: reduce roof pitch to a 4:12 pitch, rather than a 6:12
pitch as required by vested code, on the proposed house located at 1820 NE 13•• ST. Other design elements or
representations, provided within the submitted application materials, are excluded from this approval and would
be subject to the Renton Municipal Code in effect ot the time of building permit application.
If you have any further questions regarding this decision, feel free to contact the project manager, Angel ea Weihs, at
425.430.7312 or aweihs@rentonwa.gov.
2".X:4" DOU6LAS Fl'1: @ 4'
\
i'/0. 6-RADE OR EQIV
STAPUCS OR ~IRE
RIN6S (T'(PIC,AL)
FILTER FASRIC
f MATEi:1.IAL MIRAFI
140 61DIM OR
2".x:2".X:14 GA ~ELDED \i,,ee FABR,G OR ~GUAL
-EOOIVALENT
-d)-T 11" " ,:
BURY BOTTOM OF FILTER
FABRIC-MATERIAL ON
e,•·xe," TRENGH NOT TO SC.ALE
SILT FENCE ELEVATION
NE~L Y GRADED
OR DISTRIBL/TED 1.20 GAGE 1'111.RE TIEBAG.K
~E ScOPE / r,· ----+
I ~l_'-';!~ .;. r::··x :2" T .--------'st,
-1·::-_ f STAK_~------. ~"X.!: ·t-.~ "-'"-.' . ~·;;mR e_,eR,C ·.1' ; ;;,GLAS 9 _ .::l,1 I. HA ERIA~ " fl,< ,t ~ z 1 _.:j I __ 'I,_ · .
r',,'y I j;~
"f 11"=i1 , ·-"'-iTT'J
BURY BOTTOM OF
FILTER FA6RIG
MATERIAL
"'I., N f
NOT TO SC.ALE
SILT FENCE CROSS SECTION
~ ::c
M a:,
M
-I ....
IAJBLIG Rl6HT
~8-" MIN. j OF Jo',IAY
.,111:_[11_1,;p -1ffi: _111~
----'11 •--,,,-----:;1,1:::1 -11=
SECTION -m----
~ESSIN6 TO RESTORE ORl(;>INAL
-DRIVEf"lAY
RAMP
-DE DONE AS DIRECTED B'!' CIN NOT TO SC:.ALE
~ONSTRUC TION ENTRANCE
NOTE: DO NOT DISTURB GROUND IN LOCATIONS ~ OF PROPOSED DRY ~ELLS DURING
GONSTRUC TION (TYPICAL) -NO STOCKPILING
\
INSTALL ONE EAC.H DRY 1-1ELL 5' DIAMETER x 4.b' DEEP
FOR EACH l,000 SGIJARE FEET OF IMPERVIOUS
~I ~~~.P:-~~:3'.~---~:~--~~.£:r!!?(D~~-·-~.!9~~'.:! 1i\ '\,j
i N8'1°43'42"V'i 103.30' r \'/; ~
------~----------'--z;t +-, -fa·' '' _, _, ~. '
-~ 1. \\-J I
iD~ SILT 1 ·-J:, LOT 4' _\.
\., ----e 1 FENCE 'I ' ,......__. //~I) TY5ei'\
0 ,.-..-~~~·/\ -. ~B.255'
N ~ ROCKERY .G --------~------\'---",'
\....,-A C _.-j_) -\ --
---CY1-----------~~1_20' BSf:!L
I· I ~'"?J ,-1..'.._I
·OCR/ J PROPOSED
RESIDENCE
, (Hs1cisA2s-i.. -l
r---lHAIN@ 25b33 ,
.
1
, UPPER @ 2bb ee,1
1 , RID6E @ 281.01 ,,
_J
Ill tfl, ....
Ill
1f\ ..
d1-",f~ 52'-0"
ENTRY I ===-r=l ,1----~I
()
()
()
()
-,_c5,,
'\
\
'
00
\
\
'.I)
'I,'·
I ('l
'o :o
() z
"I --....._I
OJA!NER
t:XC....t:t-' flONAL N~ HOMES, LLG
5b03 SE 2ND CT
RENTON, V'<A e8o5e
TAX ACCOUNT **
33343S0-25b4
SI TE ADDRESS
LOT 4 @ SHELDEN SHORT PLAT
13XX NE 13TH ST
RENTON, V'<A e805b
LEGAL DESCRIPTION
PARCEL A:THE SOUTH 141 FEET OF
THE NORTH HALF OF TRACT 2b8. C.D.
HILLHAN'S LAKE IAIASHINGTON
6ARDEN OF EDEN. DIVISION NO. 4,
AS RECORDED IN VOLI.JME II OF
PLATS, PA6E 82, RECORDS OF KIN6
GOIJNTY, IAIASHINGTON;:'::XGEPT TH:=
SOUTH 5 F=:ET T-iER::c::: .ANJ :=xc::p-
THE JAIES-131 FEET -H'.::.REOF;
" 0
N 0
:;: =.::
ro z
"'"'"' <t ~ I-
,: "'0
·r-!. ~ w ro -~~I
:::!~(.)
> "'"' z N <: o~~
o XS: ~ ~ s:
sgg
w ""t":;;
e-"' ' 5~~
Cl) l{) z
W N ro z ~ '9
ww :-:
;;f2lli
0 !±: fE zo~
N ~
; f2
"' gj
CJ) 1-
LOT GOVERA6E
LOT ARl::A: il.15'1 S.;-:: I-ti')
HOUSE/6ARA6E AREA, 1,834 S.F. l' u LU
ENTRY/ OUTDOOR LIV: 225 S.F.
IOIAL AREA: 2,05'1 5.F. $
\,,~··-"•,_/ ,j,_/-._/,_.A~"~/,_.A,_/,~' ._/ ,_/,_;~_
1
.~--.~~"-) LJ.J
_,~v--.,,.-..._,-._,,-'v-'-.,...--._,.-.,,.---,...--_,..-._,,-.._,,-.._,.-v-,,-. ,-,_.--,,..--.,,)
,,{IMPERVIOUS AREA ) l-
/1\\ LOT AREA, 11,150 S.F. \
,__, -\ HOLJSE/C;,ARAG,E AREA: 1,834 S.F. \ -
/ ENTRY/l'ALK/OUTDOOR LIV 24b S.F. < I-
/ DRIVEV'<AY AREA 44B S.F. \ I
> TOT AL AREA 2,b54 S.F. J
'~--j~-A-~-~~~~-j'...,~=~~) u Ci::::
&;~~~~;;;;~~~;I-;;-;~-~~~~-;,;;~~~)) 0
, PLAT ARE REOWIRED TO BE EOWIPPED '
/ ~ITH AN APPROVED RESIDENTIAL FIRE j Ci::::
1. SPRINKLER SYSTEM. (BY OTHER) '1
l.l:~AAAP~-.•-_A_,.,j,.•,_p_A_A_A_A_A_J <( z
~ 8
PLAN~
T
SITE
SCALE I" = 20'-0" ANW JOB NUMBER
160014
-
! i !i ! !
! ; ,\ ! t
EXHIBIT 2
.Ii
,,,
,, i
I!
,1
1:
1, ''I
I I '
1
•. , ..• !