HomeMy WebLinkAboutLUA-16-000592_REPORT 01.t Form Reset Form Save Form
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT ---------Renton®
MODIFICATION OF RESIDENTIAL DESIGN REQUIREMENTS FOR
PROJECTS WITHIN THE R-4, R-6, R-8, R-10 AND R-14 ZONES
EVALUATION FORM & DECISION
Applicant Name:
Planning Division
1055 South Grady Way-Renton, WA 98057
Phone: 425-430-7200 I www.rentonwa.gov
APPLICANT CONTACT INFORMATION
Alexey Ancheyev I Company {if applicable):
Mailing Address: 879 Rainier Ave N Phone: (253) 820-0605
City/State: I Renton, WA Zip: 98057
PROJECT INFORMATION
Project Name: I Rathinam Residential Design Modification I Parcel Number: 13342101996
Zoning Designation: I R-8
Project Location: 3202 Burnett Ave N
Brief Summary of Request:
The applicant is requesting a modification of residential design standards in order to build a
home with less than the required 3.5 inch trim.
Please explain how your project proposal meets the "guidelines" for each design element, rather than the
standards.
Code Section: 4-2-llSE.3. "Roofs" Compliance with Guidelines:
Guideline:
Roofs shall represent a variety of forms and profiles
that add character and relief to the landscape of the
neighborhood. The use of bright colors, as well as
roofing that is made of material like gravel and/or a
reflective material, is discouraged.
Code Section: 4-2-llSE.3. "Architectural Detailing" Compliance with Guidelines:
Guideline: The proposed new single family home uses a
Architectural detail shall be provided that is modern design concept that does not work with
appropriate to the architectural character of the home. the required 3.5 inch window and door trim.
Detailing like trim, columns, and/or corner boards shall Rather, the applicant proposes to use 1 inch
reflect the architectural character of the house. window and door trim, which will compliment
the contemporary design.
1
H :\CE D\Data \Forms-Templates\Self-Help Handouts \Planning\Modificati on Application .doc Rev: 12/2015
Code Section: 4-2-llSE.1. "Garages"
Guidelines:
The visual impact of garages shall be minimized, while
porches and front doors shall be the emphasis of the
front of the home. Garages shall be located in a manner
that minimizes the presence of the garage and shall not
be located at the end of view corridors. Alley access is
encouraged. If used, shared garages shall be within an
acceptable walking distance to the housing unit it is
intended to serve
Code Section: 4-2-llSE.3. "Windows and Doors"
Guidelines:
Windows and front doors shall serve as an integral part
of the character of the home. Primary windows shall be
proportioned vertically rather than horizontally.
Vertical windows may be combined together to create
a larger window area. Front doors shall be a focal point
of the dwelling and be in scale with the home. All doors
shall be of the same character as the home.
Compliance with Guidelines:
Compliance with Guidelines:
Code Section: 4-2-llSE.3. "Primary Entry" Compliance with Guidelines:
Guidelines:
Entrances to homes shall be a focal point and allow
space for social interaction. Front doors shall face the
street and be on the facade closest to the street. When
a home is located on a corner lot (i.e., at the
intersection of two roads or the intersection of a road
and a common space) a feature like a wrapped porch
shall be used to reduce the perceived scale of the
house and engage the street or open space on both
sides.
Code Section: 4-2-llSE.3. "Fa<;ade Modulation"
Guidelines:
Buildings shall not have monotonous facades along
public areas. Dwellings shall include articulation along
public frontages; the articulation may include the
connection of an open porch to the building, a dormer
facing the street, or a well-defined entry element.
Code Section: 4-2-llSE.3. "Eaves"
Guidelines:
Eaves should be detailed and proportioned to
complement the architectural style of the home.
2
Compliance with Guidelines:
Compliance with Guidelines:
H :\CE D\Data \Forms-T em plates\Self-Hel p Handouts \Planning\Modification Application .doc Rev: 12/2015
Other Design Standard: Compliance with Guidelines:
Code Section:
Guidelines:
In addition to this form, the following attachments are required:
• Site plan and elevations (8.Sxll size)
• Built example photos (if available)
Criteria for Modification of the Residential Design Standards
Renton Municipal Code, section 4-2-115, lists elements that are required to be included in all residential developme in
the zones stated in subsection B of this Section. Each element includes both standards and guidelines. Standards a
provided for predictability. These standards specify a prescriptive manner in which the requirement can be met.
Guidelines for each element are provided for flexibility. These guidelines provide direction for those who seek to me
the required element in a manner that is different from the standards.
a. The determination as to the satisfaction of the requirement through the use of the guidelines is to be made
the Community and Economic Development Administrator when no other permit or approval requires Hear
Examiner review.
b. When it has been determined that the proposed manner of meeting the design requirement through
guidelines is sufficient, the applicant shall have satisfied that design requirement.
I, the undersigned, declare under penalty of perjury under the laws of the State of Washington, that to the best of
my knowledge the above information is true and complete.
Applicant Signature:
. '[ , .. 'fl U' Date: ____:'?<~-_\1-';3'_:::_-l--\'-l,_r,:__, ___ _
J
3
H :\CED\Data \Forms-T em plates\Self-Help Handouts\Planning\Modification Application. doc Rev: 12/2015
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
• -----:=-=------------Renton®
For City Use Only
Project Number: LUA16-000592
DECISION:
Staff agrees with the applicant's justification for Modification of Residential Design Requirements. The proposal
satisfies the criteria listed in RMC 4-2-115A2 for approval of residential design modifications. Therefore, the
Rathinam Residential Design Modification of the residential design requirements for the proposed single-family
residential structure, Project Number LUA16-000592, MOD is approved.
[g] Modification Granted D Modification Partially Granted D Modification Denied
(See attached staff comments)
Je~i~a!i~:?J=-
Sel!tember 13, 2016
Date
Department of Community & Economic Development
Conditions of Approval:
Not Applicable
The decision to approve the modification(s) will become final if not appealed in writing together with the required
fee to: Hearing Examiner, City of Renton, 1055 South Grady Way, Renton, WA 98057 on or before 5:00 pm, on
September 27, 2016. Additional information regarding the appeal process may be obtained from the Renton City
Clerk's office, Renton City Hall -7th Floor, (425) 430-6510.
This decision expressly approves the specific request(s) ta: reduce window trim width ta narrower than 3.5 inches
an the proposed house located at 3202 Burnett Ave NE. Other design elements or representations, provided
within the submitted application materials, are excluded from this approval and would be subject ta the Renton
Municipal Cade in effect at the time of building permit application.
If you have any further questions regarding this decision, feel free to contact the project manager, Angelea Weihs, at
425.430.7312 or aweihs@rentonwa.gov.
2,1€)1
&H
"'"' 240
3,elll
6UILD1Nc. uJ/ O.~ .• CA'IT'5
Dl<IVEWA,/WALK
PATIO
PORCI-I, STAIR&
TOTAL
IMPERVIOUS SUR.FACE:
8100 5.F TOTAL Lot Area
2,101 6UILD1Nc. UJ/ O.H., CANT'e,
524 DRIVEWAYJU.IALK (MAIN)
2~ FAT!O
24tZI FORCH STAIRS
2441 EXIST IMPERVIOUS AREA
6312) NEW IFERVIQJS AREA
,,e11 TOTAL
31.'31% IMFl=R.VIOUS COVERAGE
LOT COVE!<AC;E
8,100 51'. TOT AL LOT AREA
2,lell SF. BUILDING COVER.AGE
2 1'21 e,F TQT AL STRUCTURES
2i&JZ)I% COVE~E 6Y 6Tfii!LICTURE6
F'l<ESENT USE, 51'.R TEii<
Tl!xpa~sr: R.-\TH!NA\l PRADEEP+Sl-l.\RMIL
Leg a I D~&c:.rlpllOl'l:
IHLU,1.-\NS LK 'J..."\I G.-\RDF.t,.; OF FDF'J /! I WI/
OF LOT 49 TGW A.LL.OF L(JI 50 l{iW POR VAC
ALLEY ADJ
PLat Block: 16
Plat Lm: 49-5()
CB#
I
1
0
(J)
SCALE:
URBAN DESIGN GROUP
16.5'
20.0·
55.0'
-"
[Il
U)
[Il
0Aot.PHIC SCALE
"
Urban Design Group
I
(
A
i
EXHIBIT 1
36.0'
' /
' ' 4 '3S"E ?5.01'
-~~-""
I '.:P 'U
I
ok /
18"" 0NO 20.0'
I I
,---
!"-EXIST SFR T
xj'I !
' I
' ' X /(0 1" i• i~ ~(~;r.l;: tit
I
f,.i I" '"
J .~ X ,' 'Cf
' .
x.:,~-~ I \
!
{
53.5'
imii'-~--·-' _~_. J ~c-c __ ! ' . \ -c Bl J: t
~-_-_._._· ·~--_,.'j..1-..,'w,1<_ m I 13.8'
. . . .; . . . . . I I I ' ' ~ I
. DRIYEWP;Y,. . ·.' i ! I 'i i U") ' I
15 ~i~~~r. ---,.Ii LJ-J<-a'.J-1_/_5'
S89 '03'56"E 7 t
-,----,-, -_/_. ---F
32nd St.
AVERAGE GRADE CALC.
A=301.0
8=305.2
C=305.2
0=301.6 rn RTH (301.0+305.2)/2 = 303~1
ST (305.2+305.2)/2 = 305.2
UTH (305.2+301.6)/2 = 303.4
ST (301.0+301.6)/2 = 301.3
1213/4 = 303.25
SITE ADDRESS: DRAWN BY; ava
879 Rainier Ave N, Suite A-200
Renton, WA 98057
PARCEl.)34210'9%
3202BlR'iETI AVE~
RE\ TO~. WA 98056
DATE ISSUED:
P: (206) 838-8250 REVISED: &
EXHIBIT 2
~
--' i ------~ ------
l ! I
oc
~
w
I
~
\i
-~
--' I
a i i ~ g ~ -
'DDDLJ
fil I-Cl
l!I -<( '!!
~ DODD 8 >
~~ o~
";i ~~
Cl~ l'l~ ·"' ·"'' I-
-
z;,
---· ~ ()~
oc ! w
I ,ii
~ lL~
--' i ~ :;;
~
~ m .~
\i g ,~~
,t >--'~~
~~~
-I
'\'
~
~ r
2 --' I ~ --'
--' I ~ --'
w ~
,' -':1 ,' "'2
"
~-
1~ " ~Q
~ ~ 111)
FLAT l'i:Oa' A&6EMeL Y FLAT~ A&SEHel.Y !=l,.t\T~-~LY
I I I
~ I II II I :1---~---" •
--J.lAM::IIE PANEL--" • !IIDIN6
36' H. ~ILINGI
--MAJQDIE PANEL--
SIDING:
I I
I ,x 1'<IH
--I-IAIQDIE PANEL--I I SCf'l=ll, YENT '
6101NG IIN6UI..ATE CANT'L
Lil/ R-30 IN6UL.
I ----------!
I ' .. ' . . -·1L
.
,.-36' 1-1. RAIL!N6
:lX ~IM ,x 1'<IH
i 11 11 I ~
:=-!= cc •
--I-IARDIE PANEL----I-IA);!DIE PANEL--1=
.SIDING &IDIN:'.:s
AVG GR.dDE ""34)' AYG GRADE w:: ,,,.
•= """"'" . I
6AeE!1ENT
1=EFT E1=EYATION l&cff'IT, YEN't •
IN8UL.AiE cANT'L
eGALE, 1/4' • 1'·0
FLAT Roa= A56EHeL 1
I I I
1/a,12 Cd
I -
I
HAfiDIE PANEL
5ID1Ni5
--1-lARPIE PANEL--
' SIDINC:i:
' !
2X T"RJM 2X TRIM 2X TRIM
~ DD --1-lARC>IE PANEL--HAf:<DIE PANEL
%' H. RAILrNC:s --.......... 51DIN'.::I 51DINC:i:
~-
I
2X TRIM I 2X TRIM 2X TRIM
II
RIGl-4T ELEVATION
ec:ALE, 114' • l'-0'
FLAT~ A&8EMBLY
I I
~· ~
[] D II =:JI I
I o
I --I-IARDIE PANEL--1'-h' -SIDrNQ
I !-4ARDIE PANEL
SIDING
2XTRIM 2XTRIM 2X TRIM -i
-,-~ ----------
I'
--HA~IE PANEL--
SIDING !i
[ II
' -1
2X TRIM :2X TRIM :2X TRIM
I IIL_ -JI L 11
--'=-• 1-'=-J -YSOFFIT, VENT •
,.,,., _,. .. -, . INSULATE CAN.T'L
W/ R-31Z! INSJ..lL.
REAR ELEVATION
SCALE, 1/4' • l'~rZI'
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT --------Itenton@
For City Use Only
Project Number: LUAlG-000592
DECISION:
Staff agrees with the applicant's justification for Modification of Residential Design Requirements. The proposal
satisfies the criteria listed in RMC 4-2-115A2 for approval of residential design modifications. Therefore, the
Rathinam Residential Design Modification of the residential design requirements for the proposed single-family
residential structure, Project Number LUA16-000592, MOD is approved.
~ Modification Granted D Modification Partially Granted D Modification Denied
(See attached staff comments)
Se11tember 13, 2016
Jennifer Henning, Planning Director Date
Department of Community & Economic Development
Conditions of Approval:
Not Applicable CONCURRENCE
DATE q-73 zo/0
NAME INITIAL/DATE
Jennifer T. Henning 1ml at1ril l-
V) "1/ ·,ti, '11 ,·: Vanessa Dolbee •, -
Sabrina Mirante
Jennifer Cisneros ttvv a 1 !-j"LOr~~ Ange\ea Weihs
I
The decision to approve the modification(s) will become final if not appealed in writing together with the req4ired
fee to: Hearing Examiner, City of Renton, 1055 South Grady Way, Renton, WA 98057 on or before 5:00 pm, on
September 27, 2016. Additional information regarding the appeal process may be obtained from the Renton City
Clerk's office, Renton City Hall -7'h Floor, (425) 430-6510.
This decision expressly approves the specific request(s) to: reduce window trim width to narrower than 3.5 inches
on the proposed house located at 3202 Burnett Ave NE. Other design elements or representations, provided
within the submitted application materials, are excluded from this approval and would be subject to the Renton
Municipal Code in effect at the time of building permit application.
If you have any further questions regarding this decision, feel free to contact the project manager, Angelea Weihs, at
425.430.7312 or aweihs@rentonwa.gov.