HomeMy WebLinkAboutMFP23005373.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP23005373
IVR Number: 23005373
Permit Information
Permit Name: Century Link PermitsP.097812
Address/Location:10/23/2023Application Date:2923059102Parcel Number: 2640 BENSON RD S
Permit Type:12/12/2023Issue Date:Franchise
Permit Work Class:12/11/2024Expiration Date:Minor Utility
Job Number: P.097812Franchise Type:Telephone
Description: Century Link REVISION: Dig and fix broken conduit. Install 10' of new 24ct fiber.
Access MH37 to splice fiber.
Contacts
Name Address PhoneTypeBilling
Ron Desmet
Fibe Solutions
604 W Meeker St., Suite 103
KENT, WA 98032
C: (206) 571-2230Applicant
Nathan Macleod
Lumen
7850 S Trafton St, Bldg B
Tacoma, WA 98409
C: (253) 583-6283ApplicantX
Prime Electric Inc 3460 161ST Ave SE
Bellevue, WA 98008
Applicant
Austin Sweeney
Century Link
23315 66th Ave S
Kent, WA 98032
C: (253) 766-7549Applicant
Jesse Patjens
CenturyLink / Lumen
23315 66th Ave S
Kent, WA 98032
Contact
Kim Parker
QWest Corporation
931 14th St, Suite 1000A
Denver, CO 80202
B: (303) 992-0752Contact
Austin Sweeney
Century Link
23315 66th Ave S
Kent, WA 98032
C: (253) 766-7549Contact
Michael Smith
North Sky Communications
21320 84th Ave S
Kent, WA 98032
C: (206) 305-5881Contractor
Business License Number: 36846Construction Contractor: NORTHSC857Q4
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
QWest/Century Link - Billing 23315 66th Ave S
Kent, WA 98032
Specialized
Billing
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
Page 1 of 2THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
TRAFFIC CONTROL PLAN APPLICATION
Approval By: Date:
Transportation Engineering
DEPARTMENT OF PUBLIC WORKS
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
Published: 10/27/2021
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control
plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents.
2. The following items are all required for submittal of the TCP Application:
☐ Electronic Copy of the TCP Application
☐ Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall:
Include map(s) showing the location of the project and work area.
Be legible lettering and clear, contrasting, symbols of viewing or printing.
Must indicate street names, and north arrow and scale.
Types of plans required:
o Work hour plan – show all mobility impacts during construction hours.
o Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
o Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
o Pedestrian access/detour plan, if applicable.
- Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the
Evergreen Safety Council.
3. Submit Application via email to T CP@rentonwa.gov with the subject line “TCP Application – [Project Name].”
Project Name: P.097812 Permit #: MFP23005373
Site Address: 2640 Benson Rd S, Renton, WA 98055
Work Date: From 12/08/23To 6/08/24 _ Work Time: Start 8 am _ End 5 pm
Construction Company: North Sky Communications
Contact Name: Jamey Beckwith Phone/Cell: 253 221 6766
Business Address: 16701 SE McGillvray Blvd City/State: Vancouver WA
98683 Zip:
Description of Work: Access to MH37 to splice fibers for job providing bandwidth to Cell Tower.
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 1 of 3 | Published: 10/27/2021
9:00am 2:30pm
Scott Warlick CED 12/12/2023
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 3 | Published: 10/27/2021
PERMIT HOLDER AGREES TO ALL THE FOLLOWING:
• Must have approved Traffic Control Plan (TCP) prior to commencing the work.
• Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time,
with the least possible inconvenience or delay to pedestrians.
• WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the
traveled way.
• Comply with all traffic regulations of the City of Renton and the State of Washington.
• Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street
and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control
Devices.
• Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
• Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public
transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends
and holidays) prior to starting any work.
• Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum
of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a
temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a
minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140
with any questions.
• Any lane or street closures not in conformance with the approved traffic control plan and/or without notification
of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at
thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
• Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles and
the acts of the Permit Holder’s agents and employees.
• The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in
such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable
attorney’s fees and litigation costs incurred resulting from such claim.
• In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for
legal counsel chosen by the City to defend against same.
• Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
• All permit conditions shall be met.
NOTES:
• Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
• Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by a traffic control plan layout or reference to WSDOT.
• Approved Temporary Traffic Control Plan must be at the work site during work hours.
• Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
• Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery
road conditions during work and non-work hours.
• Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company
logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous
place on the vehicle or equipment.
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 3 of 3 | Published: 10/27/2021
•In the case of Temporary No Parking Zones, all the following apply in addition to previous:
•Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
•Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
•The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
•Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555
NE 2nd Street).
I certify that the information on this application and within the submittal documents are accurate to the best of my
knowledge and I acknowledge all the requirements on this application.
Applicant’s Signature Date
Applicant’s Name (Print)
12/07/23
Dwight Montague
Type text here
All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT "Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton Standards.
Traffic Control PlannerElite Traffic Solutions206-922-9205julian@elitetrafficsolutions.comRentonKing COVERSHEET1:60P.097812 98055
(1) All spacing may be adjusted to accommodate interchange ramps, at-grade intersections, and driveways.(2) This spacing may be reduced in urban areas to fit roadway conditions.
RURAL HIGHWAY SRURAL ROADSRURAL ROADS & URBAN ARTERIAL SRURAL ROADS, URBAN ARTERIAL SRESIDENTIAL & BUSINESS DISTRICTSURBAN STREETSALL SIGNS ARE 48'' X 48'' BL ACK ON ORANGE UNL ESS OTHERWISEDESIGNATED.
60/65 MPH45/55 MPH35/40 MPH25/30 MPH25 MPH OR L ESS 800'SIGN SPACING=X (FEET) (1)500'350'200'100'(2)(2)
FREEWAY S & EXPRESSWAY S 55/70 MPH 1500 (OR ASPER MUTCD)General Notes:1. No activity w ill be placed in such a way as to detour, slow or alter traffic flow during peakcommute hours. These times are generally from 7 a.m.– 9 a.m. and 3:30 p.m. – 6 p.m.The Traffic Engineer may allow an exception w ith prior approval.2. An approved traffic control plan must be on-site and accessible for inspection at all timesby law enforcement or inspectors.3. Persons in charge of maintaining or establishing traffic control and channelization musthave a certified flagger control card in their possession and must be on the site at all timesor be represented by another know ledgeable, certified person.4. When parking lanes are closed due to construction, “no parking” portables w ill beinstalled at least 48 hours in advance of the closure in unrestricted areas and 24 hours inadvance in time restricted areas. The message on the portables shall establish the date andhours for no parking.5. During emergencies w here life, property or public safety is in danger, conditions listedmay be changed. Traffic control will be addressed along w ith the initial response.6.All signs and cones shall be removed from the right-of-w ay when traffic control is not ineffect.7. Maintenance of 2-w ay traffic on arterial streets at all times except on one-way streets.Additional w idth for facilitating traffic flow may be obtained by prohibiting on-street parkingadjacent to the w ork zone.
BUFFER DATALONGITUDINAL BUFFER SPACE = BSPEED (MPH)LENGTH (FEET)25 30 35 40 45 50 55 60 65 70155200250305360425495570645730
MINIMUM TAPER L ENGTH (L ) IN FEETLaneWidthFeetPosted Speed (mph)101112 25 30 35 40 45 50 55 60 65 70105115125150165180205225245265295320450495540500550600550605660660720780840
CHANNEL IZING DEVICE SPACING (FEET)MPH TAPER TANGENT50/7035/4525/30 403020 806040
Pedestrian Escort: Stop w ork, secure passableADA compliant Pedestrian access on existingsidewalk (4' min.). Clear zone must be free ofoverhead hazards w hen Pedestrians are movingthrough the w ork area.
Traffic Control Plan: Cover Sheet
108TH AVE SE25MPH
108TH AVE SE25MPH
2625 BENSON RD S
2705 108TH AVE SE
Scope of W ork: Existing Pole Fiber to Manhole w/ Trenching
TCP 1 PPOLE-0001
M HMH-375/21/2024 by:Elite Traffic Solutions206.922.9205Christina MoulletTCS #012886, EX 6/30/2025ChrLsʤina L. Mouɸlet PPOLE-0002 PPOLE-0003
PPOLE-0004HH-1405HH
L egendMH
MH 37PPoleWork Area
w w w.invarion.com
DW
DW
DW
DW
DW
11'11'
ROADWORKAHEAD
SHOUL DERWORK XXL /3
ROADWORKAHEAD
2625 BENSON RD S
1305 S 27TH ST2705 108TH AVE SE
16415 108TH AVE SE
2640 BENSON RD S108TH AVE SE 25MPH
108TH AVE SE25MPH
16425 108TH AVE SE
City of Rentonrequires static customsigns or PCMS boardsset 7 days in advanceof the road closure thatindicates days & time ofthe closure.
Scope of W ork: Existing Pole Fiber to Manhole w/ Trenching
MINIMUM TAPER L ENGTH (L ) IN FEETLaneWidthFeetPosted Speed (mph)101112 25 30 35 40 45 50 55 60 65 70105115125150165180205225245265295320450495540500550600550605660660720780840
BUFFER DATALONGITUDINAL BUFFER SPACE = BSPEED (MPH)LENGTH (FEET)25 30 35 40 45 50 55 60 65 70155200250305360425495570645730
Traffic Control Plan: Shoulder L ane Closure Standard Notes:1. Reserve curb space w ith Traffic Permits 684-5086 in Pay Station blocks2. Haul Routes to be submitted to Don Smith, City Truck Officer, don.smith@seattle.gov3. Metro trolley coaches cannot shift more than 9' from the center of their overhead lines.Contact Metro Trolley at 477-1150 or trolley.impacts@kingcounty.gov.For Metro non-trolley coach or other transit agency relocations contact 477-1140 orconstruction.coord@kingcounty.gov4. Sidew alks are either open or not open.A sidew alk is closed if a minimum 4' path cannot be maintained measured from property line,or 5 ½' if created from face of curb5. Standard Advance Warning Signs shall be used for plates orrough road during after-hours, including “Motorcyclist” sign6. If only one lane is open in a direction, that lane shall be a minimum of 11' w ide,unless spotter/flaggers are used, in w hich case the lane can be a minimum of 10'7. Flaggers shall be used in accordance w ith WAC 468-95-302.UPO w ill be required if a traffic signal could be countermanded
All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT "Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton Standards.
Traffic Control PlannerElite Traffic Solutions206-922-9205julian@elitetrafficsolutions.comRentonKing 1 11:60P.097812 98055 1:50Plan Scale1 : 600 (1'' = 50')
DW
CHANNEL IZING DEVICE SPACING (FEET)MPH TAPER TANGENT50/7035/4525/30 403020 806040LegendConeMH
MH 37PPoleSign StandS
SpotterTrenchWork Area NSPEED LIMIT25
PPOLE-0001
25'7'
M HMH-37 PPOLE-0002 PPOLE-0003
PPOLE-0004HH-1405HH
PULL BOX
S
CONSTRUCTION SHA LL NOTIFY RESIDENTS' OF DRIVEWAYSAFFECTED BY FIBER/STRA ND INSTA LLATION OF WORK DATES & TIMES.
SPOTTER SHAL L ASSIST VEHICL ESIN & OUT OF DRIVEWAY S SAFELY.
5/21/2024 by:Elite Traffic Solutions206.922.9205Christina MoulletTCS #012886, EX 6/30/2025ChrLsʤina L. Mouɸlet
W4-119 (L)
w w w.invarion.com
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB: BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:GEO CODE: WC CLLI:TOTAL EXISTING CONDUIT USED:TOTAL NEW BORE:TOTAL NEW DIRT TRENCHESTIMATED TOTALSTOTAL NEW AERIAL:SIDEWALK (PCC) R&R:ASPHALT (AC) R&R:S.F.S.F.L.F.L.F.L.F.L.F.TOTAL NEW ASPHALT TRENCH:L.F.TOTAL NEW S/W TRENCH:L.F.010000000”NVICINITY MAPSL2640 BENSON ROADKENT, WA 98055P.097812W26226RNTNWA0123N5E2909/05/2331®CUSTOMER NAME: VERIZON WIRELESS-F1611001739LCON: KYLE FORSYTHEPHONE #: 216-505-8594EMAIL: kyle.forsythe@kimley-horn.comWFMT #: N/AORDER #: N/AARMOR OR DSR #: N/ASCOPE OF WORK:POF: @ MANHOLE 37, SPLICE COUNT LRE25, 589-590 FROM EXISTING 72-FIBER [UBY5] TO NEW 24-FIBER THEN TRENCH &PLACE 10' OF NEW 24-FIBER TO POLE-1 (A1627017). @ POLE- 1, PLACE NEW RISER UP SPLICE COUNT TO EXISTING FIBERTHRU TO POLE-4 (A1717770). @ POLE-4 (A1717770), POLE-4 (A1717770), POLE-4 (A1717770), RISER DOWN PUSHING THRUWITH EXISTING COUNT TO HANDHOLE 1405. @ HANDHOLE 1405, PUSH THRU EXISTING COUNT TO EXISTING PULL BOXATTACHED AT THE SCHOOL SITE. @ PULL BOX, CONTINUE EXISTING COUNT THRU TO VERIZON ON THE NORTH SIDE.SH OF DRAFTED BY: MOUNTAIN LTD/MT LTD ENGINEER: RICK FERDINANDOPHONE NO: 206-276-3165EMAIL: rick.ferdinando@lumen.comFIBER ENGINEER: ZACHARY THATCHERPHONE NO: 253-797-4657EMAIL: zachary.thatcher@lumen.comREVISION # SHEET # REASON FOR REVISION REVISED BY DATEREVISION - V2 1 & 3 ADDITION OF JOB N.318672 W/POLE INFO, PLACEMENT OF NEW 24-F ON DWG, DIG & FIX, UPDATE SOW, TOTALS & NOTES SL 01/19/24REVISION - V3 1 & 3 NOW ONLY PLACING FROM MH 37 TO POLE 1, UPDATE SOW, TOTALS & NOTES SL 02/12/24REVISION - V4 1 & 3 NO LONGER DIG & FIX-NOW TRENCH FROM MH 37 TO POLE 1 & POLE PLACE NEW RISER, UPDATE SOW, TOTALS & NOTES SL 05/07/24
TTTTTEEEEE CATV CATV CATV CATV CATV CATV CATV CATV GGGGG TS TS TS TS TS WWWWW S S S S S SD SD SD SD SD C/L C/L C/L C/L C/L C/L R/W R/W R/W R/W R/W R/W R/W P/L P/L P/L P/L P/L P/L B/C B/C B/C B/C B/C B/C B/C B/C EOP EOP EOP EOP EOP TTTUSAMEEPWREE CATV CATV TVTV CATV CATV CATV CATV CATV CATV CATV CATV VTS C/L C/L VWSSDVETTTXXX'XXX'XXX'XXX'X IRRIG IRRIG F1NOTICE-NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB: RNGE:SECT:TOWN:GEO CODE: WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:JOB:GEO CODE:WC CLLI:DRAFTED BY: MOUNTAIN LTD/SH OF SL2640 BENSON ROADKENT, WA 98055P.097812W26226RNTNWA0123N5E2909/05/2332®MT LTD ENGINEER: RICK FERDINANDOPHONE NO: 206-276-3165EMAIL: rick.ferdinando@lumen.comFIBER ENGINEER: ZACHARY THATCHERPHONE NO: 253-797-4657EMAIL: zachary.thatcher@lumen.com
NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS. EOP
EOP
EOP
EOP
EOP
EOP
EOP
EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP CELLTOWER EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W C/L C/L C/L C/L C/L C/L EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W 17'
T
13' EOP EOP EOP EOP EOP EOP 2640BENSON RD SPARCEL#29230591022607PARCEL#2923059061 P/L P/L P/L P/L P/L S 27th STREET5' SIDEWALKLMN HH 140512'X12' PULL BOX7+08 BLDGENTRANCEBENSON ROAD S108th AVE SESIDEWALKSIDEWALKNOTE:@ HANDHOLE 1405, PUSH THRUEXISTING COUNT TO EXISTING PULLBOX ATTACHED AT THE SCHOOL SITE.NOTE:@ PULL BOX, CONTINUEEXISTING COUNT THRU TOVERIZON ON THE NORTH SIDE.20SPEEDLIMIT20SCHOOLDURINGRESTRICTEDHOURSSPEEDLIMITT-MOBILEVERIZONT0+00 POF LMN MH 375'NOTE:POF: @ MANHOLE 37, SPLICE COUNTLRE25, 589-590 FROM EXISTING 72-FIBER[UBY5] TO NEW 24-FIBER THEN TRENCH& PLACE 10' OF NEW 24-FIBER TO POLE-1(A1627017).8' PLANTERNOTE:@ POLE- 1, PLACE NEW RISERUP SPLICE COUNT TO EXISTINGFIBER THRU TO POLE-4(A1717770).158'STATIONSCLPROPOSED HOAPOLE NUMBER(S) - LMN/PWR/OTHERPLACE NEW RISER UP/SPLICE TO EXISTING FIBERNEUTRAL & SECONDARY = 29'0"STREETLIGHT = 24'9"FIBER = 24'0"004 = 23'0", 17'0" & 14'0"005 = 22'0"313924/16617622'0"A16270170+101120'73'STATIONSCLPROPOSED HOAPOLE NUMBER(S) - LMN/PWR/OTHERCONTINUE THRU EXISTING FIBERNEUTRAL & SECONDARY = 30'0"FIBER = 22'10"004 = 22'0"005 = 21'0"316924/16619021'0"A10844731+682STATIONSCLPROPOSED HOAPOLE NUMBER(S) - LMN/PWR/OTHERCONTINUE THRU EXISTING FIBERNEUTRAL = 26'7"SECONDARY = 26'2"STREETLIGHT = 24'7"FIBER = 23'5"004 = 22'4"005 = 21'0"316924/16620321'0"A06140932+883STATIONSCLPROPOSED HOAPOLE NUMBER(S) - LMN/PWR/OTHERRISER DOWN WITH EXISTING COUNTNEUTRAL = 34'0"FIBER = 29'5"004 = 28'0"005 = 25'0"LEAVE 100' COIL316928/16620625'0"A17177703+614NOTE:@ POLE-4 (A1717770), RISERDOWN PUSHING THRU WITHEXISTING COUNT TOHANDHOLE 1405.PLANTER GRADE SOFT, ASPHALT &CONCRETE SURFACE36"MIN TRENCH DETAIL 'A'TRENCH OF 4" CONDUIT - 36" MINN.T.S.6"MIN.4" CONDUITNOTE:"REMOVE & RESTORE ALLSURFACES TO ORIGINALCONDITION."NOTICE-NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB: GEO CODE: WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSSL2640 BENSON ROADKENT, WA 98055P.097812W26226RNTNWA0123N5E2909/05/2333RSH OF DRAFTED BY: MOUNTAIN LTD/MT LTD ENGINEER: RICK FERDINANDOPHONE NO: 206-276-3165EMAIL: rick.ferdinando@lumen.comFIBER ENGINEER: ZACHARY THATCHERPHONE NO: 253-797-4657EMAIL: zachary.thatcher@lumen.com