Loading...
HomeMy WebLinkAboutMFP24001514.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP24001514 IVR Number: 24001514 Permit Information Permit Name: P.067586 Address/Location:03/25/2024Application Date:0823059167Parcel Number: 919 HOUSER WAY N Permit Type:04/10/2024Issue Date:Franchise Permit Work Class:04/10/2025Expiration Date:Minor Utility Job Number: P.067586Franchise Type:Telephone Description: Access MH 1158 for splicing maintenance, access HH 919 for splicing, HH UN 301 for pass through. Contacts Name Address PhoneTypeBilling Nathan Macleod Lumen 7850 S Trafton St, Bldg B Tacoma, WA 98409 C: (253) 583-6283ApplicantX Merilyn Luong Lumen H: (206) 806-7160 C: (206) 806-7160 Applicant Michael Smith North Sky Communications 21320 84th Ave S Kent, WA 98032 C: (206) 305-5881Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner QWest/Century Link - Billing 23315 66th Ave S Kent, WA 98032 Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 3/18/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 3/18/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐ Electronic Copy of the TCP Application ☐ Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall: ▪ Include map(s) showing the location of the project and work area. ▪ Be legible lettering and clear, contrasting, symbols of viewing or printing. ▪ Must indicate street names, and north arrow and scale. ▪ Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering P.067586 919 Houser Way N 9am 5pm P.067586 4/22/2024 4/26/2024 Northsky Comm Mike Smith 425-615-7121 16701 SE McGillivrary Blvd Vancouver WA 98683-3462 Access to MH 1158 for splicing, access HH 919 for splicing, and HH UN-301 for pass through. MFP24001514 Monday - Friday 8:00AM - 3:00PM Scott Warlick CED 4/10/2024 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 3/18/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING: • Must have approved Traffic Control Plan (TCP) prior to commencing the work. • Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. • WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way. • Comply with all traffic regulations of the City of Renton and the State of Washington. • Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. • Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. • Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. • Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. • The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. • In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. • Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. • All permit conditions shall be met. NOTES: • Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. • Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT. • Approved Temporary Traffic Control Plan must be at the work site during work hours. • Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure. • Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. • Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. • Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. • In the case of Temporary No Parking Zones, all the following apply in addition to previous: • Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. • Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 3/18/2021 • The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. • Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) Merilyn Luong 3/25/2024 SCALE: PHONE: CHC ENGINEER: PHONE: EMAIL: A CONGRUEX COMPANYR DATE: PROJECT: AMO PROJECT: ADDRESS: CITY/STATE: ZIP: COUNTY: SHEET: REVISION: 949.250.0004 TCP@CHCCONSULTING.COM PR NO. TCP COVER SHEET 03/18/24 P.067586 01 KING COUNTY 98057 RENTON/WA 919 HOUSER WAY N.VIKRAM JAGGA N.T.S. LUMEN ENGINEER:ZACHARY THATCHER 253-797-4657 TRAFFIC CONTROL PLAN GENERAL NOTES 1.ALL WORK AND MATERIALS SHALL COMPLY WITH THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) AND WASHINGTON MODIFICATIONS, LATEST EDITION. 2.ALL STRIPING AND MARKINGS SHALL CONFORM TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) AND WASHINGTON MODIFICATIONS,,STANDARD PLANS AND SPECIFICATIONS. 3.THE CONTRACTOR SHALL PROVIDE FOR ACCESS TO ALL ADJACENT PROPERTIES, AND DRIVEWAYS AT ALL TIME. 4.FLASHING YELLOW BEACONS, TYPE "B", SHALL BE USED ON ALL W20-1 SIGNS AND ON ALL TYPE III BARRICADES GUARDING THE WORK AREA OVERNIGHT. 5.ALL SIGNS SHALL BE REFLECTORIZED AND STANDARD SIZE. 6.ALL TUBULAR DELINEATORS AND CONES SHALL BE 28" MINIMUM HEIGHT, REFLECTORIZED AND MAINTAINED ERECT IN THE INDICATED POSITION AT ALL TIMES, AND SHALL BE REPAIRED, REPLACED, OR CLEANED AS NECESSARY TO PRESERVE THEIR APPEARANCE AND CONTINUITY, AND SHALL INCLUDE A 12" HIGH-INTENSITY REFLECTORIZED SLEEVE, IF USED DURING NIGHT-TIME HOURS. 7.THE CONTRACTOR SHALL MAINTAIN, ON A CONTINUOUS BASIS, ALL SIGNS, DELINEATORS, BARRICADES, ETC., TO ENSURE PROPER FLOW AND SAFETY OF TRAFFIC DURING CONSTRUCTION. 8.THE CONTRACTOR SHALL HAVE ALL SIGNS, DELINEATORS, BARRICADES, ETC., PROPERLY INSTALLED PRIOR TO COMMENCING CONSTRUCTION. 9.CONSTRUCTION OPERATIONS SHALL BE CONDUCTED IN SUCH A MANNER AS TO CAUSE AS LITTLE INCONVENIENCE AS POSSIBLE TO ABUTTING PROPERTY OWNERS. 10.ADDITIONAL TRAFFIC CONTROLS, TRAFFIC SIGNS, OR BARRICADING MAY BE REQUIRED IN THE FIELD. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PLACEMENT OF ANY ADDITIONAL DEVICES NECESSARY TO ASSURE SAFETY TO THE PUBLIC AT ALL TIMES DURING CONSTRUCTION. 11.EXACT LOCATION AND TYPE OF CONSTRUCTION SIGNS SHALL BE DIRECTED BY THE ENGINEER BASED UPON CONSTRUCTION CONDITIONS. 12.MOVE DELINEATORS AND/OR CONES TO SIDEWALK DURING NON-WORKING HOURS. REMOVE BARRICADES ETC. FROM TRAVEL LANE. 13.REMOVE OR TURN OFF SIGNS DURING NON-WORK HOURS. 14.ALL CONFLICTING LINES, EXISTING CURB PAINT, AND MARKINGS SHALL BE REMOVED BY WET SANDBLASTING OR OTHER APPROVED METHOD PRIOR TO INSTALLATION OF NEW/TEMPORARY STRIPING. ALL CONFLICTING RAISED PAVEMENT MARKERS SHALL BE REMOVED. PAVEMENT THAT IS DAMAGED DUE TO REMOVAL OF MARKERS SHALL BE REPAIRED TO THE SATISFACTION OF THE CITY ENGINEER AND/OR STATE INSPECTOR. N PR- 640522 WORK AREA 2 WORK AREA 1 MFP24001514 SIDEWALK PARKINGPARKING PARKIN G SIDEWA L K 100'100' HH #919 HH UN #301 12' MAX. 12' MAX.12'12'T.A.N.S.A.T. FLAGGERFLAGGER ACCESS TO DRIVEWAYS MUST BE MAINTAINED AT ALL TIMES. FLAGGER TO ASSIST PEDESTRIANS THROUGH WORK AREA (SEE PED NOTES) HH UN #301 IS +/- 1885' N/W OF THE C/L OF N 8TH ST. CONTACT PROPERTY OWNER(S) 72 HOURS PRIOR TO START OF WORK. A DEDICATED INDIVIDUAL WILL BE ASSIGNED THE RESPONSIBILITY OF ESCORTING PEDESTRIANS THROUGH THE WORK AREA IN ACCORDANCE WITH THREE MAJOR CONSIDERATIONS: 1.PEDESTRIANS SHOULD NOT BE LED INTO DIRECT CONFLICT WITH WORK SITE VEHICLES, EQUIPMENT OR OPERATIONS 2.PEDESTRIANS SHOULD NOT BE LED INTO DIRECT CONFLICT WITH MAINLINE TRAFFIC MOVING THROUGH OR AROUND THE WORK SITE. 3.PEDESTRIANS SHOULD BE PROVIDED WITH A REASONABLY SAFE, CONVENIENT AND ACCESSIBLE PATH THAT REPLICATES AS NEARLY AS PRACTICAL THE MOST DESIRABLE CHARACTERISTICS OF THE EXISTING SIDEWALK OR FOOTPATH PEDESTRIAN CONTROL NOTES: SPEED LIMIT25 HOUSER WAY N. SPEED LIMIT25 HOUSER WAY N. 45' SHOULDER TAPER 50' BUFFER 25' MAX.12'03/18/24 P.067586 01 KING COUNTY 98057 RENTON/WA 919 HOUSER WAY N.VIKRAM JAGGA SCALE: PHONE: CHC ENGINEER: PHONE: EMAIL: A CONGRUEX COMPANYR DATE: PROJECT: AMO PROJECT: ADDRESS: CITY/STATE: ZIP: COUNTY: SHEET: REVISION: 949.250.0004 TCP@CHCCONSULTING.COM PR NO.1:40 CHANNELIZING DEVICE S FLAGGER EXISTING DRIVEWAY HIGH LEVEL WARNING DEVICE (FLAGTREE) FLASHING ARROW BOARD SIGNALIZED INTERSECTION TOW AWAY NO STOPPING ANY TIME TYPE III BARRICADE W/SIGN TYPE II BARRICADE W/SIGN TYPE I W/ SIGN TRAFFIC CONE WITH CLIP ON SIGN DIRECTION OF TRAFFIC (NOT PAVEMENT MARKING) PORTABLE FLASHING BEACON (P.F.B.) WORK ZONE (ACTIVITY AREA) LIMITS EXISTING SIGN OF TC-2 LUMEN ENGINEER:ZACHARY THATCHER 253-797-4657 PR- 640522 TC-1 919 HOUSER WAY N. HOUSER WAY N. AND N 8TH ST. -HH UN #301 & HH #919 ACCESS WORK AREA 1 OF 2 MFP24001514 340' BUFFER 50'60' OPENING 125' MERGE TAPER 12' MAX.11'50' MAX.11'25' MAX.11'12'SIDEWALK PARKWAY PARKWAYPARKWAY PARKWAY PARKWAY PARKWAY PARKWAY PARKWAY SIDEWALK SIDEWALKSIDEWALK SIDEWALK SIDEWALKSIDEWALKSIDEWALKSIDEWALKSIDEWALKPARKWAYPARKWAYPARKWAYPARKWAYSIDEWALK SIDEWALKSIDEWALK SIDEWALK MH SPEEDLIMIT25N 8TH ST. PARK AVE. N PARK AVE. N GARDEN AVE. N S S FLAGGER MUST RIGHT LANE TURN RIGHT SPEEDLIMIT25N 8TH ST. SPEEDLIMIT25N 8TH ST. FLAGGER TO ASSIST PEDESTRIANS THROUGH WORK AREA (SEE PED NOTES) A DEDICATED INDIVIDUAL WILL BE ASSIGNED THERESPONSIBILITY OF ESCORTING PEDESTRIANS THROUGH THE WORK AREA IN ACCORDANCE WITHTHREE MAJOR CONSIDERATIONS: 1.PEDESTRIANS SHOULD NOT BE LED INTO DIRECTCONFLICT WITH WORK SITE VEHICLES, EQUIPMENT OR OPERATIONS 2.PEDESTRIANS SHOULD NOT BE LED INTO DIRECT CONFLICT WITH MAINLINE TRAFFIC MOVINGTHROUGH OR AROUND THE WORK SITE. 3.PEDESTRIANS SHOULD BE PROVIDED WITH A REASONABLY SAFE, CONVENIENT AND ACCESSIBLE PATH THAT REPLICATES AS NEARLY AS PRACTICAL THE MOST DESIRABLE CHARACTERISTICS OF THE EXISTING SIDEWALK OR FOOTPATH PEDESTRIAN CONTROL NOTES: ACCESS TO DRIVEWAYS MUST BE MAINTAINED AT ALL TIMES. CONTACT PROPERTY OWNER(S) 72 HOURS PRIOR TO START OF WORK. MH #1158 95'100' RAISED MEDIAN 100' T.A.N.S.A.T. PLACE AT THE N/E CORNER OF N 8TH ST. & PARK AVE. N 03/18/24 P.067586 01 KING COUNTY 98057 RENTON/WA 915 N 8TH ST.VIKRAM JAGGA SCALE: PHONE: CHC ENGINEER: PHONE: EMAIL: A CONGRUEX COMPANYR DATE: PROJECT: AMO PROJECT: ADDRESS: CITY/STATE: ZIP: COUNTY: SHEET: REVISION: 949.250.0004 TCP@CHCCONSULTING.COM PR NO.1:60 CHANNELIZING DEVICE S FLAGGER EXISTING DRIVEWAY HIGH LEVEL WARNING DEVICE (FLAGTREE) FLASHING ARROW BOARD SIGNALIZED INTERSECTION TOW AWAY NO STOPPING ANY TIME TYPE III BARRICADE W/SIGN TYPE II BARRICADE W/SIGN TYPE I W/ SIGN TRAFFIC CONE WITH CLIP ON SIGN DIRECTION OF TRAFFIC (NOT PAVEMENT MARKING) PORTABLE FLASHING BEACON (P.F.B.) WORK ZONE (ACTIVITY AREA) LIMITS EXISTING SIGN OF TC-2 LUMEN ENGINEER:ZACHARY THATCHER 253-797-4657 PR- 640522 TC-2 915 N 8TH ST. N 8TH ST. AND PARK AVE.N -MH#1158 ACCESS WORK AREA 2 OF 2 MFP24001514 USE TH IS NOT E WH EN OVER LAS HIN G TO EX IST ING IN BO LD REDIN A S ING LE L INE © 2024 Microsoft Corporation © 2024 TomTom EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: RNTNWAISSECTION: 8TOWNSHIP: 23NRANGE: 5ECUSTOMER INFORMATIONNAME: DISH WIRELESSCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: ZACHARY THATCHERPHONE: 253-797-4657CONTRACT ENGINEERCHC ENGINEER: SANDESH YADAVPHONE: 949-250-0004SCALE:JOB: P.067586DATE:SHEET: OF 4REVISION: 4CALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 919 HOUSER WAY N03/18/2024CONSTRUCTION NOTES:1.CALL UTILITY LOCATE AT 811 72 HOURS PRIOR TO TRENCHING OR DIGGING.2.THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES ORSTRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY FIELD INSPECTIONAND A SEARCH OF THE AVAILABLE CITY OR COUNTY RECORDS. SINCE THEACTUAL LOCATION AND NATURE OF THE UNDERGROUND FACILITIES MAY BESOMEWHAT DIFFERENT FROM THAT SHOWN. THE CONTRACTOR IS REQUIRED TOVERIFY PRIOR TO EXCAVATION.3.FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULTPRIOR TO ENTRY. PLACE WARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL, STATE,AND LOCAL REGULATIONS.4.ALL EXCAVATION, TRENCHING, AND SHORING IS TO ADHERE TO THE CODE OFFEDERAL REGULATIONS (CFR) 1926.650 SUBPART P.a. PROVIDE ALL PITS WITH 1'X1' SLOPE AT ONE END OF EXCAVATION FOR TECHNICIAN INGRESS/EGRESS.b. EXCAVATED SPOILS ARE TO BE NO LESS THAN 24" FROM EDGE OF PIT OR TRENCH.c. BARRICADE ALL OPEN PITS AND TRENCHING FOR PUBLIC SAFETY. ALLBARRICADES MUST BE EQUIPPED WITH FLASHING LIGHTS FOR NIGHT VISIBILITY.d. FOR PITS GREATER THAN 4' IN DEPTH, USE APPROPRIATE SHORING FOR WALL STABILITY5.TRENCH COVER IS TO BE 36" MINIMUM AND FREE OF ROCKS, DEBRIS, AND CLODS.THE TRENCH IS TO BE A MINIMUM OF 36" COVER IN DEVELOPED AREAS AND AMINIMUM OF 48" OF COVER IN UNDEVELOPED AREAS (ANY VARIANCE FROM THESESTANDARDS WILL BE SPECIFIED ON THE PLANS).6.ALL ASPHALT/CONCRETE AND LANDSCAPING REMOVED, DISTURBED, OR DAMAGESAS A RESULT OF CONSTRUCTION SHALL BE RESTORED TO ORIGINAL CONDITIONOR BETTER.7.NORMAL/GUIDED-BORING METHOD RECOMMENDED WHEN BORING.8.ADHERE TO AIRTIGHT GUIDELINES UNLESS OTHERWISE NOTED.9.BOND BURIED/AERIAL FACILITIES AS REQUIRED BY JURISDICTIONAL AGENCY(S).10.AERIAL FACILITIES ARE TO BE TESTED PRIOR TO BEGINING WORK PER STATE ANDLOCAL REGULATIONS.11.ALL WORK AREA PROTECTION FOR TRAFFIC CONTROL IS TO BE WITH APPROVEDWARNING DEVICES AND PLACED PER STATE DEPARTMENT OF TRANSPORTATIONAND/OR PUBLIC WORKS ENGINEERING DEPARTMENT STANDARDS ANDSPECIFICATIONS. IF REQUIRED, A TRAFFIC CONTROL PLAN SHALL BE SUBMITTEDTO THE REQUESTING PERMITTING AGENCY. PRIOR TO BEGINNING WORK,PERMITTING AGENCIES MUST BE NOTIFIED 48 HOURS IN ADVANCE OFCONSTRUCTION ACTIVITIES.12.EXISTING PEDESTRIAN CROSSWALKS AND WALKING AREAS SHALL BE MAINTAINEDAT ALL TIMES. AS NECESSARY, TEMPORARY PEDESTRIAN CROSSWALKS ANDWALKING AREAS SHALL BE PROVIDED AND MAINTAINED PER STATE DEPARTMENTOF TRANSPORTATION AND/OR PUBLIC WORKS ENGINEERING DEPARTMENTSTANDARDS AND SPECIFICATIONS.13.THE FOLLOWING FOOTAGES ARE ESTIMATES. FOOTAGES TO BE VERIFIED PRIORTO CONSTRUCTIONS.PERMITSYES /NODESIGNED SERVICES:HELD ORDERS:ROW REQUIRED:CITY:COUNTY:STATE:RAILROAD:LOOP QUAL.:PREMIS FORM:ADDITIONAL PERMIT INFO:CONFORMANCE TEST:SEE NDSERFS DATETRENCH OPEN DATE:----APPROVED MNEMONICS:ASSOCIATED PROJECTS:LCON NAME: NALCON NUMBER: NAFIBER ENGINEER: ZACHARY THATCHERFIBER ENGINEER CONTACT: 253-797-4657FIELD ENGINEER: JUSTIN CUTHBERTFIELD ENGINEER CONTACT:GLADSTONEENGINGEERINGLLC@GMAIL.COMCUSTOMER NAME:DISH WIRELESSADDRESS:919 HOUSER WAY N, RENTON, WA, 98057EQUIPMENT: (1) 12 PORT FDP, (1) CIENA 3931, (+/- 509' UG) FIBER.NOTES: NA.NARRATIVE:PLACEMENT: PLACEMENT STARTS FROM HH 919: PED BD7CMPH [KC30]. PULL NEW FIBER FROM HH 919 TO HH UN-301 TO PED BD7CMPH [KC30] TO DISH HH TO MPOP THROUGH CUSTOMER PROVIDED CONDUIT. PLACE NEW 12 PORT FDP AND CIENA 3931 ON H-FRAME AT DISH CELL SITE.SPLICING: AT EXISTING POF MH 1158. SPLICE FROM EXISTING FIBER TO EXISTING FIBER. BD7CMPH: SPLICE EXISTING FIBER TO NEW FIBER. RING CUT EXISTING FIBER FOR NEW SPLICE CASE. CELL SITE (H-FRAME): TERMINATE FROM NEW FIBER TO NEW 12 PORT FDP.CUSTOMER REQUIREMENTS: CUSTOMER TO PLACE NEW H-FRAME (CELL SITE). PROVIDE POWER SUPPLY ON PROPOSED H-FRAME. PLACE NEW GROUND SOURCE ON PROPOSED H-FRAME. DISH TO PLACE NEW HH.VICINITY MAP1NTSWHOLESALE - FTTTWORKAREAI-405HOUSER WAY NRAIL ROADCUSTOMER919 HOUSER WAY NREVISION 1 (12/06/2023):- DESIGN UPDATED AS PER LATEST STANDARD OF FTTT JOB.REVISION 2 (01/31/2024):- DESIGN UPDATED TO SHOW PLACEMENT OF FIBER FROM HH919 TO PED BD7CMPH (SEE SHEET 4).REVISION 3 (02/16/2024):- DESIGN UPDATED TO SHOW PLACEMENT OF FIBER FROM HH919 TO PED BD7CMPH THROUGH HH UN-301 (SEE SHEET 4).REVISION 4 (03/18/2024):- DESIGN UPDATED TO ADD NEW POF (MH 1158) POINT(SEE SHEET 3).POFMH 1158GARDEN AVE NLOGAN AVE N PARK AVE NN 8TH STN LANDING WAYMFP24001514 EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: RNTNWAISSECTION: 8TOWNSHIP: 23NRANGE: 5ECUSTOMER INFORMATIONNAME: DISH WIRELESSCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: ZACHARY THATCHERPHONE: 253-797-4657CONTRACT ENGINEERCHC ENGINEER: SANDESH YADAVPHONE: 949-250-0004SCALE:JOB: P.067586DATE:SHEET: OF 4REVISION: 4CALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 919 HOUSER WAY N03/18/20242NTSC/LC/LC/LC/LC/LC/LC/LC/L C/LC/LEATELEPHONE BULLET PEDESTALTELEPHONE REPEATERTELEPHONE PEDESTALTELEPHONE VAULT/HANDHOLETELEPHONE CABINETTELEPHONE MANHOLETELEPHONE COOL PEDTELEPHONE SAITELEPHONE USAMTELEPHONE OWNED POLEJOINT USE POLEACCESS POINTAERIAL SPLICE CLOSUREVERTICAL GROUNDGAS METERGAS VALVETRAFFIC SIGNAL VAULT/HANDHOLETRAFFIC SIGNAL POLEWATER METERWATER VALVEFIRE HYDRANTWATER MANHOLESTORE DRAIN CATCH BASINSTORM DRAIN INLETSTORM DRAIN MANHOLEIRRIGATION METERIRRIGATION VALVECULVERTC/L MONUMENTPOLE ITEM NO.XX'XX'XX'XX'MHTEAUSAMMHTHH HHEPWREEETVTVSVTSVWSDVCENTERLINERIGHT OF WAYPROPERTY LINEEASEMENTCURB & GUTTEREDGE OF PAVEMENTRAILROADFENCETELCOELECTRICCATVGASTRAFFIC SIGNALWATERSEWERSTORM DRAINIRRIGATIONEXISTING AERIAL OR UNDERGROUND FIBEREXISTING AERIAL STRAND2'x2' RECEIVING PIT4'x4' BORE PITSAICOOL PEDESTALELECTRIC PEDESTALTELCO HANDHOLETELCO PEDESTALTELCO CABINETTELCO MANHOLER/WEOPTECATVGASTSWSC/LP/LP#HH HHELECTRIC PEDESTAL/CABINETELECTRIC TRANSFORMERELECTRIC METERELECTRIC VAULT/HANDHOLEELECTRIC MANHOLEELECTRIC J-BOXSTREETLIGHTCATV BULLET PEDESTALCATV PEDCATV VAULT/HANDHOLESEWER MANHOLELIGHT TREE TRIMMEDIUM TREE TRIMHEAVY TREE TRIMLMHTRENCHBOREASPHALT TRENCHAERIAL BUILDAERIAL BUILDSLACK SPANAERIAL STRANDANCHOR & DOWN GUYDOWN GUYASPHALT TRENCH FOOTAGEDIRT OR S/W TRENCH FOOTAGEBORE FOOTAGEAERIAL FOOTAGEANCHOR & DOWN GUYUNDERGROUND FIBER PLACEMENT THROUGH EXISTING CONDUITSDIRRIGMFP24001514 EOPEO PEOPEOPEOPEOPEOP C/LC/LC/LC/LC/LC/LC/LR/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WEOPEOPEOPEOPEOPC/LC/LC/LR/WR/WEOPEOP E O P EOPC/L C/L R/W R/WEOP C/LC/LC/LEOPParcel #:0886600040Parcel #:0886600029EOPEOPParcel #:0886610070Parcel #:0886610012Parcel #:0886610010SPEEDLIMIT25SPEEDLIMIT25SPEEDLIMIT20SPEEDLIMIT30R/WMH00+00POFMH 1158- 13' from EOP- In dirt- Splice LocationN 8TH STN 8TH STPARK AVE NPARK AVE NSidewalk SidewalkDirtDirtDirtSidewalkSidewalkGrassExisting FiberSidewalk Sidewalk Sidewalk Sidewalk Grass DirtDirt Dirt88'80' 58'12'11'11'12'1' 11'104'60'12'12'12'12'11'1'92'58'12'11'12'22'1'60'12'12'13'11'11'1'EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: RNTNWAISSECTION: 8TOWNSHIP: 23NRANGE: 5ECUSTOMER INFORMATIONNAME: DISH WIRELESSCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: ZACHARY THATCHERPHONE: 253-797-4657CONTRACT ENGINEERCHC ENGINEER: SANDESH YADAVPHONE: 949-250-0004SCALE:JOB: P.067586DATE:SHEET: OF 4REVISION: 4CALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 919 HOUSER WAY N03/18/202431" = 30'See Sheet 4 MFP24001514 HOUSER WAY NEOPEOPEOPEOPEOPEOPC/LC/LC/LC/LC/LC/LR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WP/LP/LP/LP/LR/WR/WR/WR/WR/WR/WR/WParcel #:0823059168Parcel #:0823059167Parcel #:0823059218Parcel #:6145601126SidewalkD/WDirt GrassDirtEOPEOPFenceEOPP/LP/LSidewalkD/WEOPD/WI-405DISH HH- (In Asphalt)- Pass ThroughMPOP45+47Pull new fiber from HH 919 to HH UN-301 toPED BD7CMPH [KC30] to DISH HH to MPOPthrough Customer provided conduit.PLACE NEW 12 PORT FDP AND CIENA3931 ON H-FRAME AT DISH CELL SITE.CUSTOMER:919 HOUSER WAY NHHHHVICINITY MAPNSOUTHPORTDR NNESUNSETBLVDHOUSER WAY NI-405R.R.42+3844+67HH HHSPEEDLIMIT25SPEEDLIMIT25HH UN-301- (4' from EOP)- Pass ThroughPED BD7CMPH [KC30]- (In Asphalt)- Pass through44+1644+8513'19'ParkingParkingSPEEDLIMIT60HHHHHHHHHHHHHH UN-301HH 919PED BD7CMPH[KC30]DISH HHRailTracksCELLSITEDirt Grass13'8'19'40'60'40'8' HH HHHH 919- (9' from EOP)- Splice Location- 655' Southeast from SOUTHPORTDR N & HOUSER WAY N Intersection60'Existing FiberEXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT. THESE DRAWINGS ANDSPECIFICATIONS SHALL REMAIN THE PROPERTY OF CENTURY LINK BEING ISSUED IN STRICTCONFIDENCE AND SHALL NOT BE REPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.CLLI: RNTNWAISSECTION: 8TOWNSHIP: 23NRANGE: 5ECUSTOMER INFORMATIONNAME: DISH WIRELESSCITY, STATE: RENTON, WAENGINEERING CONTACTNAME: ZACHARY THATCHERPHONE: 253-797-4657CONTRACT ENGINEERCHC ENGINEER: SANDESH YADAVPHONE: 949-250-0004SCALE:JOB: P.067586DATE:SHEET: OF 4REVISION: 4CALL TWO WORKING DAYSBEFORE YOU DIG811ZIPCODE: 98057ADDRESS: 919 HOUSER WAY N03/18/202441" = 30'See Sheet 3MFP24001514