Loading...
HomeMy WebLinkAboutW-425504Z ti O Z O 450 „m 430 420 51f34.97, 7.00' RT 1-12 x8" TEE (FL) SEE SHEET 2-12" GA VE VAL VE (FLxM✓) PROPERTY LINE 1-8" GAVE VAL I/E (FLxM✓) (TYP) C6, O5 W/ CONC BLOCKING I�11,\ �_ - . , 1 1 �/tiv X� ~ I 11 EX OFFSITE TREE I \ \ 23 22 21-0 TO REMAIN (TYP) . �.: a: 43� � _ 19� A 0`�23p5Yg�C I z� � P UONG M 25LF 8" y• TRACT M _ - (OPEN SPACE) I I/IIVIIl\f I�I TRACT N 8 SEE SHEET (OPEN SPACE) C6.05 WA TER BSBL (TYP) WATER EASEMENT (TYP) 18+00 18+50 19+00 19+50 7 19 18 17 V I \v � � /\\ 1568-D1 � 6) 19*42.64, 3.00' RT 1-11.25° BEND (M✓) W/ CONC BLOCK/NG 19f57.73, 6.00' RT 1-11.25° BEND (MJ) W/ CONC BLOCKING 20+00 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG. 811 SEESHEET C6.01 II 10' UTILITY EASEMENT (TYP) u I 16 15 14 13 1 Ll fl7 J. i RESTRAINED JOINT PIPING i TRACT 0 5 (OPEN SPACE) 11 4 \ 3 RESTRAINED SEE SHEET 20*05. 00, 6. 00' RT JOINT 1-12"x8" CROSS (FL) PIPING C6, 01 2-12 GA TE VAL Vf- (FLxM✓) 2-8" GATE VAL I/ES (FLxM✓) W/ CONC BLOCKING 450 430 420 20+50 „m STANDARD I" WATER SERVICE C.O.R. STD DTL 320.1 PROPERTY LINE PER SEE SHEET C6.31 (TYP) (TYP) 11 U LJ I EX GROUND 15 CONTOUR (TYP) 12 11 10 21*76.51, 6.00' RT 1-8" PLUG )VJ) 1-2" BLOW -OFF ASS? LIT W/ CONC BLOCK/NG 1-8" POL YP/GG/NG STATION I PER COR STD. PLAN NO. 300.7 ?LF 80 D/ I 2" BLOW OFF PER C. O.R. STD DTL 340.1, SEE SHEET C6.32 (TYP) 1 3p5,9235 _LC 1� ApN 04ASSOCIAiE m PROPOSED FIMSH m GRADE CONTOUR 11 2 1 I I (Typ) WA TER EASEMENT (TYP) WA TER BSBL (TYP) SEE SHEETS C7.02-C7.04 FOR UTILITY CROSSING NFORMAT/ON. SCALE: 1" = 30' 0 15 30 60 . . . . . . . . mo�O h^ W . o Q PROPOSED GRADE s N W 9 ROAD f (TYP) OPOSED 8" In 1 TER (TYP) W N O N "� o EX/STING GROUND 0 ROAD (TYP) Q . v r . Q . . . . . . . . . . . . . . . . . . o i O j . . . . . . . . PROPOSED ELEV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 ROAD f (TYP) RO 1 . EX/STING ELEV. HOR/Z. SCALE.• 1 "=30' ® ROAD f (TYP) INERT. SCA E.• 1 "5' . 20+00 20+50 21+00 1 REVISED PER CITY COMMENTS MJS 7/26/231 HHH SURVEYED: BY OTHERS 2 REVISED PER CITY COMMENTS KEL 9/12/23 HHH DESIGNED: ROLL/ HEAVR/N 3 REVISED PER CITY COMMENTS KEL 10/11/22 HHH DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N NO. REVISION BY DATE APPR APPROVED: ROLL/ HEA VR/N SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY NE 2TH ST `(EYMAP WA TER LEGEND WA TER MAIN WA TER EASEMENT - — — — — — — - WA TER BSBL EX/STING WATER PIPE IV] IN[ WATER FITTING Ak FIRE HYDRANT ® WA TER METER •� TYPE / BLOW -OFF �t AIR- VAC GENERAL NOTES 440 1. MAX/MUM ALLOWABLE DEFLECTION AT EACH JOINT SHALL NOT EXCEED ONE-HALF THE MANUFACTURERS RECOMMENDED PERMISSIBLE DEFLEC77ON. 2. ALL CONSTRUC77ON SHALL BE /N ACCORDANCE WITH THE CITY OF RENTON STANDARD SPECIFICATIONS. 3. LOCA77ONS OF EXISTING U77LI77ES SHOWN ARE APPROXIMATE. EX/S77NG U77LI77ES SHALL BE FIELD LOCATED BY RESPEC1TVE U77LITY COMPANIES PRIOR TO CONSTRUC77ON. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONNEC77ONS TO EXIS77NG PIPES 430 FOR PROPER RT77NGS AND DEPTH. 5. CONTRACTOR SHALL N077FY ALL AFFECTED U77LI77ES 24 HOURS PRIOR TO CONS7RUC77ON 6. ALL WATER RT77NGS AND VAL VES WITH MECHANICAL JOINT (MJ) END(S) SHALL HAKE A WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. 7. CONCRETE THRUST BLOCKS REQUIRED ON ALL WATER RT77NGS PER C.O.R. STD PLAN 340.1. 8. WHERE NEW WATER MAIN CROSSES A NON -POTABLE PIPE, ONE FULL 420 LENGTH OF WATER PIPE SHALL BE USED WITH THE PIPE CENTERED FOR MAXIMUM JOINT SEPARATION. 410 21+50 22+00 22+50 VERnCAL• NAVD 1988 HORIZONTAL- NAD 1983/1991 CITY OF 0 RENTON DATUM Planning/Building/Public Works Dept. L 0 O O N N 10/11 /23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE ,con PLANNING �zw� DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 W-425504 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING yqi 12/06/2023 ' WATER UTILITY ABDOUL GAFOUR 11/09/2023 DATE: O TOWNS ON 12TH 101111202J 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: PAGE: WA TER PLAN & PROF/LE DRAWING N0: O C6.03 � ROW 1 & ROW 2 SHEET: 51 OF: 93