Loading...
HomeMy WebLinkAboutS-425502Z ti O Z O TRACT H (CRITICAL AREA) EX TREE TO BE SA VED (TYP) 10' UTILITY EASEMENT (TYP) m n 0 cr, RS c') cr + 0 N O 14149.57, ROAD A = 50f 00.00, ROW 5 L V430 IWv1 J, (Z' 420 O V Q410 v � � SHEET C5.06 ccuico �inAiuni c TYPE 1-48" RIM 427.78 8" 1E IN 414.58 (5) 8" If /N 414.58 (W) 8" IE OUT 414.48 (N) SIDE SEWER PER C. O.R. STD DTL 406.1, SEE SHEET C5.31 (TYP) nrr n/ /rrT SEE SHEETS C5.09-010 FOR SEWER SERVICE LINE DESIGN (TYP) STA. 12f83.35, 5.00' L T TYPE 1-48" RIM 430.18 8" IE /N 415.39 (5) 8" 1E /N 415.39 (W) 8" If /N 415.39 (E) 8" 1E OUT 415.29 (N) oononccn cmccr STA. 11*48.29, 5.00- L T TYPE 1-48" RIM 428.69 8"lE/N416.17(W) 8"IE/N 416.17(E) 8" IF OUT 416.07 (N) SEE SHEET C5.O8 SEE SHEET C5.08 EX GROUND CONTOUR (TYP) 10f 00.00, ROAD A = 81f89.10, NE 12TH ST HIGH PT STA: 12f85.84 . HIGH PT Z L: 430.28 . LOW PT STA: 10 65.77 PW STA: 13f00.00 LOW PT EL: 42788 h PW EL: 430.68 ' oo oo PW STA: 10*60.00 . 100.0 12f84.29 ROAD A VC h 11Ko PV/ EL: 427. 8 0 PROPOSED GRADE = o; 30f00 =ROW 3 IN o ^ o ., Q 0 50.00 VC o o Q^ p 0 ROAD f (TYP) Lc) ^� EL: 430.28 ^d Q s o EX/STING GROUND c� c� 12f89.35 = ROAD A > > . . . . �;; W it0 ROAD (TYP)W W 54f59.91 ROW 4 EL: 430.28 �� _ ^o� Q2� l� - ��. .NNW W �hW - - 1.259 � . . . . . . . - _. \ 2 '+ -24 . 0 . I I. . . . . . . . . . . . . . . . . . . . . . . . . 0 . . . . . . . . . . . . . . . . . . . . . . . I. I 135LF 8" PVC 0 0.0050 . . . . . . . . . . . . . . . . . . . . . . . 142LF 8" PVC 0 0.0050 0 82LF 8" PVC 0 0.0050 0 . zt .� N d N- N- '* . ;! N rr '1- <1 . . . . . . 75 . . . . . . . . . . . . . 00 00 41 00. . . . . . . h�00 �b Cb . . . . . . . . . . . . . . . . . . . . . . . . . ...... . . . . . . . . ...... . ROAD . . . ..... . . . ................. . . . . . . . . . . . . . . . EX/STING ELf .. PROPOSED ELEV. HOR/Z. SCALE.• 1 "30' 0 ROAD (TYP) 0 ROAD (TYP) VERT. SCALE 1 N=5' 15+00 14+50 14+00 13+50 13+00 12+50 12+00 11+50 11+00 UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG! 8/ 1 REVISED PER CITY COMMENTS MJS 7/26/231 HHH 2 REVISED PER CITY COMMENTS KEL 9/12/23 HHH 3 REVISED PER CITY COMMENTS KEL 10/11/22 HHH NO. REVISION BY DATE APPR SURVEYED: BY OTHERS DESIGNED: HOLL/ HEA VR/N DRAWN: MARY MOORE CHECKED: HOLL/ HEA VR/N APPROVED: HOLL/ HEA VR/N 10+50 SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 10+00 VERnCAL• NAVD 1988 HORIZONTAL- NAD 1983/1991 DATU M MI SEWER LEGEND 0 0 SEWER P/PE SEWER SERVICE SEWER EASEMENT EX/STING SEWER PIPE SEWER P/PE FLOW ARROW SEWER STRUCTURE SEWER CLEANOUT GENERAL NOTES `(EYMAP SCALE: 1" = 30' 0 15 30 60 1. ALL CONSTRUCAON SHALL BE /N ACCORDANCE WITH CITY OF RENTON STANDARD SPEC/F/CAAONS. 2. WHERE THE WATER MAIN /NSTALLAAON CROSSES OVER SANITARY SEWERS, THE MIN/MUM I/ERACAL SEPARAAON SHALL BE 18 INCHES, OR CONSTRUC17ON SHALL BE /N ACCORDANCE WITH DOE CRITERIA FOR SEWAGE WORKS DESIGN (SEE DETAILS). 3. ALL SIDE SEWER TEES SHALL BE FIELD LOCATED. 4. CONTRACTOR SHALL FIELD VERIFY CONNECTION TO EXISTING PIPE FOR PROPER AS -BOIL T 430 ELEVATION PR/OR TO CONSTRUCAON OF MANHOLE 0VfR LINE 420 410 CITY OF RENTON Planning/Building/Public Works Dept. SIDE SEWER NOTES 1. MIN/MUM SLOPE ON 6'� S/DE SEWER LINES /S 29 2. UNITS NUMBERS MARKED WITH A "*" WILL HA VE BACKWA TER VAL VfS INSTALLED ON THE PRIVATE SIDE (UPSTREAM) OF THE CLEANOUT AT THE END OF THE SIDE SEWERS. 3. SEE SEWER SERVICES PLAN ON SHEET C5.09 AND C5.10 FOR SIDE SEWER /NFORMA AON. 10/11 /23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE 'Con PLANNING �zw� DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 S-425502 IN COMPLIANCE WITH CITY OF RENTON STANDARDS WASTEWATER UTILITY �!% DEVELOPMENT ENGINEERING jstowell 11 /13/2023 yqi 12/06/2023 DATE: TOWNS ON 12TH 10/11/2023 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: PAGE SA NITA R Y SEWER PLAN & PROF/LE C5.01 ROAD A (START-1 5+00) SHEET: OF: 37 93 O O O N N