HomeMy WebLinkAboutS-425512Z ti O Z O M1 v 5' I B, NOT TO SCALE MANHOLE FRAME AND COVER SEE STD PLAN 401 ADJUSTMENT RINGS AND MORTAR JOINTS SEE NOTE 3 FIRST STEP SHALL BE A MAXIMUM OF 18" BELOW THE COVER CONE (ECCENTRIC) STEPS - POLYPROPYLENE STEPS SHALL BE INCLUDED RUBBER GASKETED JOINTS SEE NOTE 5 IF REQUIRED, LADDER -POLYPROPYLENE SHALL BE ATTACHED TO MANHOLE MAX PIPE SIZE - 'E' SHELF AND CHANNEL SHALL BE 3000 PSI CONCRETE PRECAST BASE SECTION OR CAST IN SHELF COMPACTED SUBGRADE WITH 6" CRUSHED ROCK OR ADDITIONAL MATERIAL SUITABLE TO SUPPORT STRUCTURE 'A'I 'B' 'C' 'D' 'E' 48" MH 48" 6" MIN. 5"MIN 24" MIN. 21" I D 54" MH 54" 8" MIN 5 5" MIN 24" MIN 24" 1 D 60" MH 60" 8" MIN 6" MIN 42" MIN 30" 1 D NOTES. 1 STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED 2 MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE IN CONFORMANCE WITH ASTM C-478. 3 ADJUSTMENT OF THE CASTING TO GRADE SHALL BE PER STD PLAN 106 THE USE OF SHIMS IS PROHIBITED. 4 SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING, FACTORY -COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING, WASSER MC-SHIELDCOAT 100 OR APPROVED EQUAL, COLOR OF COATING SHALL BE WHITE 5 RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443 6 CHANNEL WIDTH AND HEIGHT SHALL EQUAL THE INSIDE DIAMETER OF THE LARGEST PIPE 7 CONNECTIONS TO MANHOLE SHALL BE MADE USING KOR-N-SEAL BOOTS OR APPROVED EQUAL 8 IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A MAXIMUM OF 12" ABOVE FINISHED GRADE OR MUST HAVE AN AT -GRADE, MINIMUM 2'-WIDE CONCRETE RING POURED AROUND THE COVER IN PAVED AREAS, COVER MUST SLOPE TO MATCH PAVING. 9 MANHOLES OVER 20' DEEP SHALL BE A MINIMUM OF 60" IN DIAMETER STD. PLAN - 400.1 • PUBLIC WORKS yney DEPARTMENT STANDARD SANITARY MANHOLE M26/202 Martin Pastucf��i rn'ncwd+r:'.bAS,i,�449D DATE r.,j r-m-r---------- --- EX. SEWER MAIN I I I I l PROPERTY LINE JSEWESR POOLZ (LENGTH AS NEEDED) iiiS-O" MIN 6" SEWER STUBFUTURE 4" SIDE SEWER 2"x 4" STUD MARKING POST PAINTED 6" CAPJJJ WHITE MATH THE WORD "SEWER" STENCILED MAIN TEE X 6" TEE i i i IN 3" HIGH BLACK LETTERS AND #6 WARE SIDEWALK • ?WRAPPED AROUND THE STUD AND \ EXTENDED TO THE TOP OF THE STUD ` COUPLING TYP ( ray 13 6"X6"X6" SURFACE CLEANOUT WITH CAST IRON RING AND COVER O (EAST JORDAN IRON WORKS PRODUCT NO 00367502 OR APPROVED EQUAL, SPECIFY "SEWER" ON LID), CLEANOUT TO BE CENTERED IN A 2'x2' CONCRETE PAD CONCRETE PAD TO BE 8" IN DEPTH • I 1--- `---j BEND AS e" REQUIRED EXISTING SANITARY SEWER MAIN t-2 0R MIN SLOPE 1 \\a \\ \ ` FUTURE 4" SIDE SEWER �6" SEWER STUB `6"X6"X6" WYE FUTURE 6"x 4" REDUCER `SEWER MAIN SIZE X 6" TEE ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO EXISTING SEWER MAIN A VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). B CONCRETE MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL) C PVC & C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E LINED MAIN - CONNECTION TO SEWER MAINS THAT HAVE BEEN LINED (CIPP, ETC), CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). F HDPE - CORE -DRILLED WITH A ROMAC SADDLE "INSERTA-TEE" MAY BE USED ON SEWER MAINS 12" DIAMETER OR LARGER G MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALL BE CORE -DRILLED AND USE KOR-N-SEAL BOOTS OR APPROVED EQUAL NOTES 1 PRIOR TO INSTALLATION OF A SANITARY SEWER STUB, A SIDE SEWER STUB PERMIT MUST BE PURCHASED FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT 2 UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2 5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER 3 SIDE SEWERS SHALL HAVE A MINIMUM 2 % SLOPE UNLESS APPROVED BY THE PUBLIC WORKS INSPECTOR 4 FOR INSPECTION OF THE SIDE SEWER STUB, CALL 24 HOURS IN ADVANCE. THE INSPECTION PHONE NUMBER IS ON THE SIDE SEWER STUB PERMIT SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE ON SITE WHEN INSPECTOR ARRIVES AT THE APPOINTED TIME DO NOT BACKFILL THE TRENCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR 5 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 1102 6 THE SIDE SEWER STUB SHALL HAVE PIPE BEDDING IN ACCORDANCE WITH STANDARD PLAN 405 7 ALL SIDE SEWER STUBS SHALL BE INSTALLED BY A CONTRACTOR LICENSED AND BONDED IN THE STATE OF WASHINGTON SIDE SEWER STUB pp�� yqq STD. PLAN -406.1 A PPROvI•ry- `R3 PUBLIC WORKS INSTALLATION "Tnad by DEPARTMENT Martin PaStUCh@✓26/202' (SEWER MAIN TO PROPERTY LINE) _a,, „ .. DATE BOLTHOLES - 3 PLCS SxNOn NpNI EQUALLY SPACED 120' fwallor is"3 APART ON 23 1/16' (586mm) DIA BC (SEE DETAIL) RENTON SEWER IL1pC IN USA COVER & FRAME PLAN VIEW 25' DIA [635mm] 1' 3/4' C25mm] C19mm] 8 3/4' 2 1/2' C222mm] [64mm] TYP COVER SECTION VIEW 26 112' DIA [673mm] 25 1/4' DIA 16, 'm] 1 1/16' 1/4' (6mm) DIA [27mm] NEOPRENE GASKET 6' fAr: C151 mm] 5/8' 23 3/8' DIA CL ❑PEN [16mm] [594mm] 27 5/16' DIA [694mm] 34 1/8' DIA COVER BOTTOM VIEW 3) BLT SOC (ALLEN HEAD) 5/8'-11 X 15 SS \ RUBBER WASHER BOLTING DETAIL 1/4' 1 1/16' C6mm] (27mm) (3mm] 1/8, [R3mm] GASKET GROOVE DETAIL [867mm] NOTES FRAME SECTION VIEW 1 ALL FRAME AND COVER ASSEMBLIES SHALL HAVE A LOCKING LID PER EAST JORDAN IRON WORKS INC PRODUCT No 00371572 OR EQUAL. 2 USE FRAME AND COVER FOR SANITARY (SPECIFY "SEWER") • STD. PLAN - 401.1 .�PUBLIC WORKS SEWER MANHOLE FRAME AND COVER �5°°°hY '�„ DEPARTMENT (CITY -OWNED) Martin Pastucffg Z6/zoz 8449D.. DATE MAXIMUM DISTANCE BETWEEN SPACERS SHALL BE 6 FEET ON CENTER SEAL BOTH ENDS OF CASING WITH A MANUFACTURED RUBBER SEALING DEVICE, MODEL "W" BY PIPELINE SEAL & INSULATOR OR APPROVED EQUAL PLACE END SPACER MAXIMUM OF 12" FROM END OF CASING (TYP.) 1— ONE SPACER SHALL BE PLACED ON THE SPIGOT END OF EACH SEGMENT AT THE LINE MARKING THE LIMIT OF INSERTION INTO THE BELL. WHEN THE JOINT IS COMPLETE, THE SPACER SHALL BE IN CONTACT WITH THE BELL OF THE JOINT SO THAT THE SPACER PUSHES THE JOINT AND RELIEVES COMPRESSION WITHIN THE JOINT. STEEL PIPE CASING (MILL PIPE) OR DUCTILE IRON USE 2 STAINLESS STEEL HOSE CLAMPS TO SECURE RUBBER SEAL (1 ON CARRIER PIPE AND 1 ON CASING PIPE) CARRIER PIPE CARRIER PIPE DIAMETER 4" 6" 8" 10" 12" CASING DIAMETER (PUSH -ON JOINT CARRIER PIPE) 10" 12" 14" 16" 20" STEEL CASING THICKNESS 0 25" 0 25" 0 25" 0.25" 0.25" SPACER BAND WIDTH 8" 8" 8" 8" 8" NOTES: 1 CASING SPACERS SHALL BE "CENTER POSITIONING" TYPE CASCADE WATERWORKS MFG OR APPROVED EQUAL 2 MINIMUM RUNNER WIDTH SHALL BE 2 INCHES 3. RUNNER HEIGHT SHALL BE SIZED TO PROVIDE A. MINIMUM 0.75" BETWEEN CARRIER PIPE BELL AND CASING PIPE WALL AT ALL TIMES B MINIMUM 1" CLEARANCE BETWEEN RUNNERS AND TOP OF CASING WALL TO PREVENT JAMMING DURING INSTALLATION 4 STEEL CASING DIAMETERS ARE "OUTSIDE DIAMETER" FOR 16" AND LARGER 5 SPACER BAND WIDTH SHALL BE 12" FOR CARRIER PIPES THAT ARE 36" DIAMETER OR GREATER. 6 FOR CARRIER PIPES EXCEEDING 12" IN DIAMETER, CASING DIAMETER AND THICKNESS SHALL BE DESIGNED BY AN ENGINEER. 7 FOR STEEL CASING, PROVIDE SHOP -APPLIED ANTI -CORROSIVE COATING ON CASING EXTERIOR CONFORMING TO AWWA 210 PRODUCT SHALL BE TNEMEC HI -BUILD TNEME-TAR SERIES 46H-413 OF APPROVED EQUAL MINIMUM COATING THICKNESS SHALL BE 16 MILS OFT. 8. STEEL CASINGS SHALL EXTEND A MINIMUM OF 5 FEET BEYOND ANY WALLS OR STRUCTURES. 9 PRIVATE LATERALS ONLY: CASING SPACERS ARE NOT REQUIRED AS LONG AS THE LATERAL CARRIER PIPE DOES NOT HAVE BELLS THAT WILL FALL WITHIN THE LENGTH OF THE CASING END SEALS ARE REQUIRED FOR ALL LATERAL CASING PIPES. STD. PLAN - 412 R,." PUBLIC WORKS CASING PIPE DEPARTMENT FOR MAIN LINES & LATERALS Martin PastuCIAW26/202 v„wc WorZTAdini,F"9 p84490 DATE UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DIG. 8/g1 TEE OF APPROPRIATE SIZE USE ROMAC COUPLING OR APPROVED EQUAL WHEN 60" MIN CONNECTING TO AN EXISTING FOR NEW MANHOLES SEWER MAIId ft SEE NOTE 7 "RELINER" BRAND STAINLESS STEEL ADJUSTABLE CLAMPING BRACKETS OR APPROVED EQUAL . f 90' BEND EMBEDDED IN CONCRETE 1/2 THE DIAMETER OF ' THE DOWNSTREAM PIPE NOTES 1. SANITARY SEWER DROPS ARE ONLY TO BE USED UPON APPROVAL BY THE WASTEWATER UTILITY SECTION 2 DROP PIPES AND FITTINGS SHALL BE PVC SDR 35 WHEN CONNECTING TO ALL EXISTING SEWER MAIN MATERIALS EXCEPT DUCTILE IRON. USE AWWA C900 PIPE AND AWWA C907 FITTING WHEN CONNECTING TO DUCTILE IRON SEWER MAINS 3 MINIMUM SIZE MANHOLE FOR INSIDE DROP CONNECTION SHALL BE 60" DIAMETER 4 CONNECTIONS TO MANHOLE SHALL BE CORE DRILLED AND USE KOR-N-SEAL BOOTS OR APPROVED EQUAL 5 USE ROMAC COUPLING OR APPROVED EQUAL WHEN CONNECTING TO AN EXISTING MAIN 6 WITHIN A 60" DIAMETER MANHOLE, THE MAXIMUM ALLOWABLE DIAMETER OF THE INSIDE DROP PIPING IS 12" INSIDE DROPS EXCEEDING 12" IN DIAMETER OR MULTIPLE DROPS SHALL BE REVIEWED BY THE WASTEWATER UTILITY AND MAY REQUIRE A LARGER DIAMETER MANHOLE. 7 "RELINER" BRAND STAINLESS STEEL ADJUSTABLE CLAMPING BRACKETS OR APPROVED EQUAL SHALL BE INSTALLED WITHIN 6" OF BOTH BELL AND SPIGOT ENDS OF EACH DROP PIPE IF DROP PIPE LENGTH EXCEEDS 5 FEET THEN CENTER STRAPS SHALL BE INSTALLED WITH A MAXIMUM SPACING OF 4 FEET ON CENTER BRACKETS SHALL BE ATTACHED UTILIZING STAINLESS STEEL EXPANSION BOLTS, MIN 2 EACH AT CONNECTION POINTS 8 MANHOLE CONE SECTION AND ACCESS LADDER MAY NEED TO BE RELOCATED TO ALLOW DROP ST ..PLAN - 402.2 PUBLIC WORKS INSIDE DROP CONNECTION APPROVEVRI D DEPARTMENT FOR SANITARY MANHOLE Martin Pastuchcj0/26/2 NOik w"„f ♦em""nro, DATE NOTES 1. CONTRACTOR SHALL USE A HYDRAULIC POWERED CHA/NSAW WITH A DIAMOND BLADE FOR CUTTING EXISTING CONCRETF BENCH, SEVERAL CUTS SHALL SE MADE WHERE THE 90 W/LL SE EMBEDDED AND REUOVf- THE PIECES WITH A ROTO—HAMMER, TO PREI/ENT ANY CONCRETE DEBRIS FROM GOING DOWN THE PIPE CONTRACTOR W/LL INSTALL SCREENING ACROSS THE CHANNEL WHILE WORK /S BEING PERFORMED. 2. CONTRACTOR SHALL POTHOLE AROUND THE EX/ST/NG STRUCTURE AND DETERMINE SIZE OF EXISTING CAISSON. L OCA T/ON OF CONNECTION SHALL BE TORCHED OR CUT THROUGH CAISSON AND THEN CORE DRILLED FOR NEW CONNECT/ONPEA GRA l/EL AROUND STRUCTURE SHALL BE VACTORED OUT DOWN TO CONNECT/ON POINT, PR/OR TO CORE DRILLING, AND THEN BACKF/LLED AFTER INS/DE DROP CONNECTION /S COMPLETE. J INFORMAT/ON NOT PRO1/DED WITHIN THIS DETA/L SHALL FOLLOW THOSE OF C/TY OF RENTON STANDARD PLAN 402,2 A80VE. TOP OF PIPE SHALL MATCH CROWN OF EXISTING CHANNEL EX/ST/NG 22" P/PE ✓OTE 2 PIPE SHALL BE EMBEDDED /N CONCRETE, SEE NOTE 1 BELOW INSIDE DROP - CONNECTION TO EX MH 1 REVISED PER CITY COMMENTS MJS 7/26/231 HHH SURVEYED: BY OTHERS 2 REVISED PER CITY COMMENTS KEL 9/12/23 HHH DESIGNED: ROLL/ HEAVR/N 3 REVISED PER CITY COMMENTS KEL 10/11/22 HHH DRAWN: MARY MOORE CHECKED: ROLL/ HEA VR/N NO. REVISION BY DATE APPR APPROVED: ROLL/ HEA VR/N NO SCALE SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATUM CITY OF RENTON Planning/Building/Public Works Dept. W (SEE NOTE 7) BEDDING MATERIAL FOR SANITARY SEWER PIPE (SEE NOTE 5) --\ FOUNDATION LEVEL LIMITS OF PIPE ZONE .31 O.D. of PIPE 6" BEDDING FOR SANITARY SEWER PIPE NOTES: 1. PROVIDE UNIFORM SUPPORT UNDER BARREL 2. HAND TAMP UNDER HAUNCHES. 3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. HAND TAMP ONLY. 4. PIPE INSTALLATION SHALL BE PER SECTION 7-08 OF THE STANDARD SPECIFICATIONS 5 PIPE ZONE MATERIAL SHALL BE PER SECTION 9-03.12(3) OF THE STANDARD SPECIFICATIONS 6. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW LINE IS MAINTAINED 7 TRENCH WIDTH SHALL BE PER SECTION 2-09.4 OF THE STANDARD SPECIFICATIONS. STD. PLAN - 405 PUBLIC WORKS PIPE BEDDING APP V:R] DEPARTMENT FOR SANITARY SEWERS Martin PastuCW26/202 w•n, n01FD98vB449D DATE 0 0 N O N v O O O N N 10/11 /23 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE ,con PLANNING �zw� DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 S-425512 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING IL WASTEWATER UTILITY :011 -F yqi 12/06/2023 jstowell 11 /30/2023 L� NN 1 O TOWNS ON 12TH DATE: 10/111202J 3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK: PAGE: DRAWING NO: SANITARYSEWER STANDARD DETAILS C5.31 2 SHEET: OF: 47 93