REINFORCEMENT SCHEDULE
TOTAL WALL
REINFORCEMENT
REINFORCEMENT
HEIGHT
HEIGHT "H"
LAYER NO.
TYPE
LENGTH"L"
(FT)
<3 FT
NO REINFORCEMENT REQUIRED
1
MIRAFI 5XT
11.0 FT
0.67
3 FT
2
MIRAFI 5XT
11.0 FT
2.00
1
MIRAFI 5XT
11.0 FT
0.67
5 FT
2
MIRAFI 5XT
11.0 FT
2.00
3
MIRAFI 5XT
11.0 FT
4.00
1
MIRAFI 5XT
11.0 FT
0.67
2
MIRAFI 5XT
11.0 FT
2.00
6 FT
3
MIRAFI 5XT
11.0 FT
4.00
4
MIRAFI 5XT
11.0 FT
5.33
NOTE: GEOGRID ELEVATION TOLERANCE t .5' (ALL DIMENSIONS ARE IN FEET)
GENERAL NOTES
1) REFER TO CIVIL GRADING PLANS FOR WALL ALIGNMENTS AND ELEVATIONS.
2) REFER TO REINFORCING SCHEDULE FOR GEOGRID LENGTHS AND ELEVATIONS.
3) GEOGRID ELEVATION MEASURED FROM TOP OF CRUSHED ROCK LEVELING PAD.
4) GEOGRID LENGTH "L" MEASURED FROM BACK OF FACE UNIT_
5) GEOGRID SHALL BE INSTALLED BEHIND WALL WITH MACHINE DIRECTION (STRONGEST AXIS)
PERPENDICULAR TO WALL.
6) GEOGRID SHALL BE INSTALLED ON HORIZONTAL SURFACE OF COMPACTED STRUCTURAL FILL.
7) GEOGRID SHALL BE PULLED TIGHT BEHIND WALL. STAKE END OF GEOGRID AS REQUIRED TO MAINTAIN
TENSION BEFORE COVERING WITH STRUCTURAL FILL.
8) PROTECT GEOGRID FROM CONSTRUCTION DAMAGE PER MANUFACTURERS SPECIFICATIONS.
CONSTRUCTION EQUIPMENT SHALL NOT TRAVEL DIRECTLY ON GEOGRID. ANY GEOGRID THAT IS DAMAGED
SHALL BE REPLACED WITH NEW GEOGRID AT CONTRACTORS EXPENSE.
9) SEGMENTAL BLOCK WALL ASSEMBLY TO BE COMPLETED PER MANUFACTURERS SPECIFICATIONS.
10) STRUCTURAL FILL SHALL BE PLACED AND COMPACTED IN 12-IN LOOSE LIFTS TO 95% OF THE SOILS
MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D-698. THE MOISTURE CONTENT OF THE MATERIAL
SHALL BE WITHIN 2% OF THE SOILS OPTIMUM AS DETERMINED BY THIS SAME STANDARD. STRUCTURAL FILL
IN REINFORCED ZONE SHALL BE GRANULAR MATERIAL WITH MAXIMUM AGGREGATE SIZE OF 31NCHES AND
A MAXIMUM SOILS FINES (LESS THAN #200 SIEVE) CONTENT OF 20 PERCENT.
11) HEAVY CONSTRUCTION EQUIPMENT SUCH AS VIBRATORY DRUM ROLLERS, LOADED DUMP TRUCKS,
FRONT-END LOADERS, ETC., SHALL NOT OPERATE WITHIN FIVE FEET OF BACK OF WALLS. STRUCTURAL
FILL PLACED IN THIS ZONE SHALL HAVE MAXIMUM LOOSE LIFT THICKNESS OF 12 INCHES AND SHALL BE
COMPACTED USING HAND OPERATED COMPACTION EQUIPMENT.
FENCE OR HANDRAIL
AS REQUIRED
SWALE FOR SURFACE DRAINAGE CONTROL
f
-H13
1 _
FIRM UNDISTURBED 112 IN.
SOIL TO BE VERIFIED KEYWAY
BY GEOTECHNICAL ENGINEER
KEYWAY SHOULD BE SLOPED
DOWN TOWARDS THE FACE
BEING PROTECTED
NOT TO SCALE
ROCKERY NOTES:
COMPETENT UNDISTURBED NATIVE SOILS
CRUSHED ROCK FILER
MATERIAL BETWEEN 2,
AND 4 INCH SIZE WITH
LESS THAN 2% FINES
3" MIN
GRAVEL BEDDING
6" MINIMUM DIAMETER
DRAIN PIPE SURROUNDED BY
CLEAN WASHED 3/4" DRAIN
GRAVEL TAKEN TO APPROVED
POINT OF DISCHARGE
1. REFER TO CIVIL GRADING DRAWINGS FOR
WALL ALIGNMENTS, AND ELEVATIONS.
2. ROCKERY CONSTRUCTION SHALL BE COMPLETED
IN ACCORDANCE WITH THE ASSOCIATION OF ROCKERY
CONTRACTORS GUIDELINES.
3. ROCK USED MUST MEET THE REQUIREMENTS
FOR ROCK QUALITY SPECIFIED IN SECTION 9-13.7(1)
OF THE WSDOT STANDARDS SPECIFICATIONS (2016).
4. ALL CAP ROCKS MUST BE SECURE AND NOT ABLE
TO BE DISLODGED BY HAND.
7 a I-a3
Terra CUT ROCKERY DETAIL
TOWNS ON 12TH
Associates, Inc. RENTON, WASHINGTON
Consultants in Geotechnical Engineering
Geology and
Environmental Earth Sciences Proj. No.T-8566 Date JULY 2023 F Figure 4
FENCE/RAIL WHERE
REQUIRED n 2(MAX)
1
SEGMENTAL BLOCK 8"X18"X12" OR
EQUAL
II
LAYER 4
12" MIN. COMPACTED STRUCTURAL~
1 - U BACK FILL ABOVE DRAIN COLUMN
LAYER 3
„H„ 32 GEOGRID (SEE REINFORCING SCHEDULE)
� ' .
12" MIN. COMPACTED 1/2" TO 1"
CLEAN CRUSHED ROCK NO FINES (TYP.)
} L11 LAYER 2
GRANULAR FILL COMPACTED TO 95%
OF SOILS MAXIMUM DRY DENSITY PER
ASTM D-1557 MODIFIED PROCTOR (SEE NOTE 10)
_ a LAYER 1
1' - - - - - - - - - - - - - - -
(MIN.) 4" DIAMETER PERFORATED PVC
DRAIN PIPE TAKEN TO APPROVED
POINT OF DISCHARGE
6 T I 3, - �I
COMPETENT NATIVE SOILS
OR STRUCTURAL FILL TO BE VERIFIED
BY GEOTECHNICAL ENGINEER (TYP.)
UNDERGROUND LOCATOR SERVICE
CALL BEFORE YOU DIG.
811
5/8" CRUSHED ROCK LEVELING PAD (TYP.)
1
REVISED PER CITY COMMENTS
MJS
7/26/,-
2
REVISED PER CITY COMMENTS
KEL
9/12/,-
3
REVISED PER CITY COMMENTS
KEL
0/1 1/:
N0.
REVISION
BY
DATE
REINFORCEMENT SCHEDULE
EXPOSED
REINFORCEMENT
REINFORCEMENT
HEIGHT
WALL
LAYER NO.
TYPE
LENGTH"L"
(FT)
HEIGHT "H"
<3 FT
NO REINFORCEMENT REQUIRED
1
MIRAFI 5XT
3.0 FT
0.67
3 FT
2
MIRAFI 5XT
3.0 FT
2.00
1
MIRAFI 5XT
4.5 FT
0.67
5 FT
2
MIRAFI 5XT
4.5 FT
2.00
3
MIRAFI 5XT
4.5 FT
4.00
1
MIRAFI 5XT
6.5 FT
0.67
2
MIRAFI 5XT
6.5 FT
2.00
7 FT
3
MIRAFI 5XT
6.5 FT
4.00
4
MIRAFI 5XT
6.5 FT
6.00
1
MIRAFI 5XT
8.5 FT
0.67
2
MIRAFI 5XT
8.5 FT
2.00
9 FT
3
MIRAFI 5XT
8.5 FT
4.00
4
MIRAFI 5XT
8.5 FT
6.00
5
MIRAFI 5XT
8.5 FT
8.00
1
MIRAFI 5XT
9.5 FT
0.67
2
MIRAFI 5XT
9.5 FT
2.00
3
MIRAFI 5XT
9.5 FT
4.00
10 FT
4
MIRAFI 5XT
9.5 FT
6.00
5
MIRAFI 5XT
9.5 FT
8.00
6
MIRAFI 5XT
9.5 FT
9.33
NOTE: GEOGRID ELEVATION TOLERANCE f .5' (ALL DIMENSIONS ARE IN FEET)
GENERAL NOTES
1) REFER TO CIVIL GRADING PLANS FOR WALL ALIGNMENTS AND ELEVATIONS.
2) REFER TO REINFORCING SCHEDULE FOR GEOGRID LENGTHS AND ELEVATIONS.
3) GEOGRID ELEVATION MEASURED FROM TOP OF CRUSHED ROCK LEVELING PAD.
4) GEOGRID LENGTH "L" MEASURED FROM BACK OF FACE UNIT.
5) GEOGRID SHALL BE INSTALLED BEHIND WALL WITH MACHINE DIRECTION (STRONGEST AXIS) PERPENDICULAR TO WALL.
6) GEOGRID SHALL BE INSTALLED ON HORIZONTAL SURFACE OF COMPACTED STRUCTURAL FILL.
7) GEOGRID SHALL BE PULLED TIGHT BEHIND WALL. STAKE END OF GEOGRID AS REQUIRED TO MAINTAIN TENSION BEFORE COVERING WITH
STRUCTURAL FILL.
8) PROTECT GEOGRID FROM CONSTRUCTION DAMAGE PER MANUFACTURERS SPECIFICATIONS. CONSTRUCTION EQUIPMENT SHALL NOT
TRAVEL DIRECTLY ON GEOGRID. ANY GEOGRID THAT IS DAMAGED SHALL BE REPLACED WITH NEW GEOGRID AT CONTRACTORS EXPENSE.
9) SEGMENTAL BLOCK WALL ASSEMBLY TO BE COMPLETED PER MANUFACTURERS SPECIFICATIONS.
10) STRUCTURAL FILL SHALL BE PLACED AND COMPACTED IN 12-IN LOOSE LIFTS TO 95% OF THE SOILS MAXIMUM DRY DENSITY AS DETERMINED
BY ASTM D-698. THE MOISTURE CONTENT OF THE MATERIAL SHALL BE WITHIN 2% OF THE SOILS OPTIMUM AS DETERMINED BY THIS SAME
STANDARD. STRUCTURAL FILL IN REINFORCED ZONE SHALL BE GRANULAR MATERIAL WITH MAXIMUM AGGREGATE SIZE OF 31NCHES AND A
MAXIMUM SOILS FINES (LESS THAN #200 SIEVE) CONTENT OF 20 PERCENT.
11) HEAVY CONSTRUCTION EQUIPMENT SUCH AS VIBRATORY DRUM ROLLERS, LOADED DUMP TRUCKS, FRONT-END LOADERS, ETC., SHALL NOT
OPERATE WITHIN FIVE FEET OF BACK OF WALLS. STRUCTURAL FILL PLACED IN THIS ZONE SHALL HAVE MAXIMUM LOOSE LIFT THICKNESS OF
12 INCHES AND SHALL BE COMPACTED USING HAND OPERATED COMPACTION EQUIPMENT.
H H H
SURVEYED:
8Y OTHERS
H H H
DESIGNED:
HOLLI HEA VRIN
H H H
DRAWN:
MARY MOORE
CHECKED:
HOLLI HEA VRIN
AP P R
APPROVED:
HOLLI HEA VRIN
AS NOTED
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL. NAVE) 19a8
HORIZONTAL- NAD 1983/1991
DATUM
FENCE/RAIL WHERE
REQUIRED n 2(MAX)
SEGMENTAL BLOCK 8"X18"X12" OR
EQUAL
"H"
1
32
Eli
LAYER 6
12" MIN. COMPACTED STRUCTURAL
BACK FILL ABOVE DRAIN COLUMN
U LAYER 5
GRANULAR FILL COMPACTED TO 95%
OF SOILS MAXIMUM DRY DENSITY PER
ASTM D-1557 MODIFIED PROCTOR
(SEE NOTE 10)
LAYER 4
12" MIN. COMPACTED 1/2" TO 1"
CLEAN CRUSHED ROCK NO FINES (TYP.)
LAYER 3
- GEOGRID (SEE REINFORCING SCHEDULE)
- - - - - - - - LAYER 2
LAYER 1
4" DIAMETER PERFORATED PVC
DRAIN PIPE TAKEN TO APPROVED
POINT OF DISCHARGE
6
OILS - 3,
COMPETENT NATIVE S5/8" CRUSHED ROCK LEVELING PAD (TYP.)
OR STRUCTURAL FILL TO BE VERIFIED
BY GEOTECHNICAL ENGINEER (TYP.)
CITY OF
,R RENTON
Planning/Building/Public Works Dept.
1, -
(MIN.) I
0"w 1-
J-.2
10/11 /23
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
,con PLANNING
"`1111zw� DESIGN SURVEYING
12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877
R-425519
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
O
O
O
N
N
DEVELOPMENT ENGINEERING
yq i 12/06/2023 Pz
N
TOWNS ON 12TH DAT-1011112023 O�
3916 & 3926 NE 12TH ST, RENTON, WA 98056 FIELDBOOK:
PAGE:
DRAWING NO:
ROAD STANDARD DETAILS C3.43
SHEET: OF:
19 93