Loading...
HomeMy WebLinkAboutR-4255540 �i 0 c» N 0 N m 0 GENERAL IRRIGATION NOTES PART 1 1. THE IRRIGATION SYSTEM WILL BE DESIGNED, INSTALLED AND MANAGED USING THE ISSAQUAH HIGHLANDS MASTER WATER CONSERVATION PROGRAM. 2. IRRIGATION WILL BE PROVIDED TO ALL LANDSCAPING UNLESS OTHERWISE NOTED. 3. FULL AND COMPLETE HEAD TO HEAD IRRIGATION COVERAGE IS REQUIRED. MAKE ADJUSTMENTS TO LAYOUT FOR IRRIGATION ZONE PRESSURE AND TO ACHIEVE FULL COVERAGE OF IRRIGATED AREAS WITHOUT OVERTHROW ONTO ROADWAYS, SIDEWALKS OR BUILDINGS. 4. MAINTAIN A COMPLETE SET OF RECORD DRAWINGS, CORRECTED DAILY, TO SHOW LOCATION OF SYSTEM COMPONENTS. SUBMIT COPIES AS REQUESTED. 5. AT COMPLETION, SUBMIT 1 FULL SIZE AND ONE HALF SIZE CAD PRODUCED PLAN AT THE SAME SCALE AS THE CONSTRUCTION PLANS, INDICATING THE LOCATIONS OF MAINLINES, VALVES, BACKFLOW PREVENTION DEVICES, ZONE OUTLINES AND OTHER SYSTEM ELEMENTS. INDICATE LOCATIONS WITH DIMENSIONS FROM BUILDINGS, CURB LINES OR OTHER FIXED SITE FEATURES. INCLUDE ONE COPY OF CAD FILE ON CD. 6. SUBMIT TWO SETS OF KEYS, QUICK COUPLER OPERATING KEYS, AND UNIQUE TOLLS OR DEVICES NEEDED TO ACCESS, OPERATE, ADJUST OR MAINTAIN THE SYSTEM. OBTAIN RECEIPT INDICATING LOCATION AND CUSTODIAN OF EACH SET. 7. MAKE REPAIRS AND REPLACEMENTS AND GUARANTEE THE SATISFACTORY OPERATION OF THE SYSTEM IN EVERY DETAIL FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE. ALL WARRANTY REPAIRS OR REPLACEMENTS SHALL BE AT THE CONTRACTOR'S EXPENSE. 8. TESTING: a. NOTIFY THE OWNER AT LEAST 48 HOURS PRIOR TO ALL TESTS AND INSPECTIONS. INSPECTION REPORTS MUST BE MADE FOR ALL TESTS. b. THOROUGHLY FLUSH PIPING BEFORE TESTING AND INSTALLATION OF SPRINKLERS. C. TEST ALL EXPOSED MAINLINE PIPING, VALVES, JOINTS AND FITTINGS AT 150 PSI. IF PRESSURE LOSS OCCURS BEYOND ACCEPTED MAXIMUM, INSPECT THE ENTIRE SYSTEM, MAKE WATERTIGHT AND RETEST TO MEET SPECIFICATIONS. d. SYSTEM WILL PASS TEST WHEN IT MAINTAINS LESS THAN A 5% DROP OVER A 30-MINUTE TEST PERIOD. 12. INSPECTION: UPON COMPLETION OF THE INSTALLATION AND ADJUSTING OF THE IRRIGATION SYSTEM, NOTIFY THE OWNER FOR A SYSTEM INSPECTION. AT THAT TIME PRESENT THE FOLLOWING. a. ZONE BY ZONE SYSTEM DEMONSTRATION AND COVERAGE TEST. b. LOCATION OF MAJOR SYSTEM COMPONENTS. C. WINTERIZATION AND MAINTENANCE PROCEDURES. d. PROCEDURES FOR SETTING THE CONTROLLER. 1. PIPE: a. MAINLINE AND LATERAL LINES: MAINLINE 2" SCHEDULE 40 PVC PIPE. LATERALS NSF APPROVED CLASS 200 PVC. 2. FITTINGS: a. SOLVENT WELDED SOCKET TYPE: ASTM D 2466, PVC. PIPE FITTING. SCHEDULE 40. b. THREADED TYPE: ASTM D 2464, PVC PIPE FITTINGS, SCHEDULE 80. C. SLEEVES: ASTM D 1785, NSF APPROVED, PVC SCHEDULE 40. 3. JOINTING MATERIALS: a. PVC SOLVENT CEMENT: WELD- ON PLASTIC PIPE CEMENT, 721 FOR PVC b. PVC PRIMER AND CLEANER: WELD -ON PRIMER P-70 PUC/CPUC PURPLE PRIMER. C. TEFLON TAPE SEALER: 1/2 INCH WIDE, USED AT ALL THREADED JOINTS. 1. VALVES AND ACCESSORIES: a. AUTOMATIC CONTROL VALVE: RAINBIRD PEB SERIES. b. GATE VALVE: BRASS, LINE SIZE. C. MANUAL DRAIN VALVE: BRASS 3/4 INCH BALL VALVE. a. QUICK COUPLING VALVE: BRONZE, TWO PIECE CONSTRUCTION, 1 INCH SIZE, RAINBIRD44LRC, OR APPROVED EQUAL, ON A 1 INCH 3-WAY LASCO PVC SWING JOINT. 5. VALVE BOXES: a. CONTROL VALVES: 11" X 17" CARSON VALVE BOX b. GATE VALVES: CARSON 10" ROUND. C. HOSE BIBS AND QUICK COUPLER VALVES: CARSON 10" ROUND. d. BACK FLOW PREVENTION DEVICES: AS PER CITY OF ISSAQUAH SPECIFICATIONS. b. MANUAL DRAIN VALVES: CARSON 6" ROUND VALVE BOX. 6. GATE AND DRAIN VALVE OPERATING KEY: HEAVY GALVANIZED IRON KEY. 7. QUICK COUPLER KEY AND HOSE SWIVEL: BRASS, AS SUPPLIED BY THE RAINBIRD CORPORATION TO FIT THE QUICK COUPLER AS SHOWN ON DRAWINGS. 8. BACKFLOW PREVENTION DEVICES: WILKINS 950XLT, 11" DOUBLE CHECK VALVE. 9. PRESSURE REDUCING VALVE: 12 WILKINS 600 10. AUTOMATIC CONTROLLERS: ISSAQUAH HIGHLAND CUSTOM AS PROVIDED BY UNITED PIPE AND SUPPLY REDMOND, WASHINGTON. NO EXCEPTIONS. 11. WATER METER: SENSUS METER, SRIITRPL IN CUBIC FEET WITH AMR REGISTER AND LID ADAPTERS PER CITY OF ISSAQUAH SPECS. 12. FLOW SENSORS: DATA INDUSTRIAL, IR-220P 13. SPRINKLERS: ROTOR HEADS TO BE MP ROTATORS, SPRAY HEADS TO BE RAINBIRD 1812-SAM WITH MPR NOZZLES 2.4 DRIPLINE SYSTEM A. DRIPLINE AND INTEGRAL DRIPLINE COMPONENTS: THE DRIPLINE SHALL BE PRESSURE COMPENSATING DRIPLINE. DRIPPER FLOW RATE AND SPACING SHALL BE AS INDICATED ON SCHEDULE. 1. DRIPLINE FITTINGS: ALL DRIPLINE CONNECTIONS SHALL BE MADE WITH APPROVED INSERT FITTINGS; MANUFACTURER EQUAL TO THAT OF DRIPLINE. 2. SOIL STAPLES: ALL ON-SURFACE/UNDER MULCH DRIPLINE INSTALLATIONS SHALL BE HELD IN PLACE WITH SOIL STAPLES SPACED EVENLY EVERY 5' ON CENTER, AND WAT EACH FITTING 3. LINE FLUSHING VALVES: ALL DRIPLINE SYSTEMS SHALL BE INSTALLED WITH MANUAL OR AUTOMATIC LINE FLUSHING VALVES, AS SPECIFIED ON DRAWINGS. 4. AIR/VACUUM RELIEF VALVES: DRIPLINE SYSTEMS SHALL BE INSTALLED WITH AIR/VACUUM RELIEF VALVES ONLY WHERE INDICATED ON DRAWINGS. 5. DISC FILTER: A DISC FILTER SHALL BE INSTALLED AT EACH ZONE VALVE OR ON THE MAIN LINE TO ENSURE PROPER FILTRATION . THE FILTER SHALL BE A TORO DISC FILTER (ALFD75150-L) OR APPROVED SUBSTITUTE. 14. LOW VOLTAGE CONTROL WIRE: a. WIRE: SOLID COPPER, UL LISTED FOR DIRECT BURIAL IN GROUND, MINIMUM SIZE #14, UP TO 1,500 FT. AND #12, ABOVE 1,500 FT., CONTROLLER A (RED FOR POSITIVE, WHITE FOR COMMON), CONTROLLER B (BLUE (OR NON -RED) FOR POSITIVE, WHITE FOR COMMON). ALL SPARE WIRES TO BE ORANGE. b. CONNECTORS: DBY OR DBR AS MANUFACTURED BY 3-M CORPORATION. UNDERGROUND LOCATOR SERVICE CALL BEFORE YOU DI C.I 8// EOUIPMENT SCHEDULE SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY 1, isf ♦f � HUNTER PROS-02 SR SERIES 67 TURF SPRAY, 21N. POP-UP. CO -MOLDED WIPER SEAL WITH UV RESISTANT 2Q 2H 4Q 6Q 6H MATERIAL. 0 ® 0 HUNTER PROS-02 5 SERIES 27 TURF SPRAY, 21N. POP-UP. CO -MOLDED WIPER SEAL WITH UV RESISTANT Q H F MATERIAL. HUNTER PROS-02 8 SERIES 13 TURF SPRAY, 21N. POP-UP. CO -MOLDED WIPER SEAL WITH UV RESISTANT Q T H F MATERIAL. Is 0140 HUNTER PROS-02 10 SERIES 7 TURF SPRAY, 21N. POP-UP. CO -MOLDED WIPER SEAL WITH UV RESISTANT Q T H F MATERIAL. 0 F 01000 HUNTER 0 12 SERIES 4 TURF SPRAY,, 21N2 POP-UP. CO -MOLDED WIPER SEAL WITH UV RESISTANT Q T H TT TQ F MATERIAL. '1 a 0 O HUNTER PROS-02 15 SERIES 11 H TURF SPRAY, 21N. POP-UP. CO -MOLDED WIPER SEAL WITH UV RESISTANT QQ T TT TQ I MATERIAL. ® r HUNTER PROS-02 17 SERIES 2 TURF SPRAY, 21N. POP-UP. CO -MOLDED WIPER SEAL WITH UV RESISTANT Q H MATERIAL. HUNTER PROS-02 ADJ SERIES 91 TURF SPRAY, 21N. POP-UP. CO -MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. © HUNTER PROS-00 SR SERIES 544 SHRUB SPRAY, FIXED RISER. CO -MOLDED WIPER SEAL WITH UV RESISTANT 2Q 2H 4Q 4H 6Q 6H MATERIAL. HUNTER PROS-00 5 SERIES 161 SHRUB SPRAY, FIXED RISER. CO -MOLDED WIPER SEAL WITH UV RESISTANT Q H F MATERIAL. O HUNTER PROS-00 8 SERIES 279 SHRUB SPRAY, FIXED RISER. CO -MOLDED WIPER SEAL WITH UV RESISTANT Q T H F MATERIAL. HUNTER PROS-00 STRIP SERIES 22 SHRUB SPRAY, FIXED RISER. CO -MOLDED WIPER SEAL WITH UV RESISTANT SST MATERIAL. �,, 9 HUNTER PROS-00 10 SERIES 242 SHRUB SPRAY, FIXED RISER. CO -MOLDED WIPER SEAL WITH UV RESISTANT Q T H F MATERIAL. s HUNTER PROS-00 12 SERIES 49 SHRUB SPRAY, FIXED RISER. CO -MOLDED WIPER SEAL WITH UV RESISTANT Q T H TT TQ F MATERIAL. n tF�71 HUNTER PROS 00 15 SERIES 17 SHRUB SPRAY, FIXED RISER. CO -MOLDED WIPER SEAL WITH UV RESISTANT Q T H TT TQ MATERIAL. HUNTER PROS-00 17 SERIES 1 SHRUB SPRAY, FIXED RISER. CO -MOLDED WIPER SEAL WITH UV RESISTANT Q H MATERIAL. O Q HUNTER PROS-00 ADJ SERIES 192 SHRUB SPRAY, FIXED RISER. CO -MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY ""� RAIN BIRD 3504-PC-SAM 0.75 2 TURF ROTOR, 41N. POP-UP. ADJUSTABLE AND FULL CIRCLE. WITH SEAL-A-MATIC CHECK VALVE. RAIN BIRD 3504-PC-SAM 1.0 6 TURF ROTOR, 41N. POP-UP. ADJUSTABLE AND FULL CIRCLE. WITH SEAL-A-MATIC CHECK VALVE. RAIN BIRD 3504-PC-SAM 1.5 2 TURF ROTOR, 41N. POP-UP. ADJUSTABLE AND FULL CIRCLE. WITH SEAL-A-MATIC CHECK VALVE. RAIN BIRD 3504-PC-SAM 4.0 1 TURF ROTOR, 41N. POP-UP. ADJUSTABLE AND FULL CIRCLE. WITH SEAL-A-MATIC CHECK VALVE. 7 RAIN BIRD 3500-S-PC-SAM 0.75 11 SHRUB ROTOR, FIXED RISER, ADJUSTABLE AND FULL CIRCLE. WITH SEAL-A-MATIC CHECK VALVE. ORAIN 1.0 BIRD 3500-S-PC-SAM 1.0 9 SHRUB ROTOR, FIXED RISER, ADJUSTABLE AND FULL CIRCLE. WITH SEAL-A-MATIC CHECK VALVE. ORAIN 1.5 BIRD 3500-S-PC-SAM 1.5 6 SHRUB ROTOR, FIXED RISER, ADJUSTABLE AND FULL CIRCLE. WITH SEAL-A-MATIC CHECK VALVE. 2.0 O RAIN BIRD 3500-S-PC-SAM 2.0 9 SHRUB ROTOR, FIXED RISER, ADJUSTABLE AND FULL CIRCLE. WITH SEAL-A-MATIC CHECK VALVE. ORAIN 3.0 BIRD 3500-S-PC-SAM 3.0 2 SHRUB ROTOR, FIXED RISER, ADJUSTABLE AND FULL CIRCLE. WITH SEAL-A-MATIC CHECK VALVE. SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY AREA TO RECEIVE DRIPLINE RAIN BIRD XFS-CV-09-12 XFS-CV SUB -SURFACE AND ON -SURFACE LANDSCAPE DRIPLINE WITH A 10,748 L.F. HEAVY-DUTY 4.3 PSI CHECK VALVE. 0.9 GPH EMITTERS AT 12" O.C. DRIPLINE LATERALS SPACED AT 18" APART, WITH EMITTERS OFFSET FOR TRIANGULAR PATTERN. SPECIFY XF INSERT FITTINGS. SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY RAIN BIRD EFB-CP 11N., 1-1/21N., 21N. BRASS REMOTE CONTROL VALVE, THAT IS CONTAMINATION 84 PROOF W/SELF-FLUSHING FILTER SCREEN. GLOBE CONFIGURATION, RECLAIMED WATER COMPATIBLE, AND PURPLE HANDLE COVER DESIGNATES NON -POTABLE WATER USE. BF ZURN 950XL 1" 1 DOUBLE CHECK VALVE ASSEMBLY RAIN BIRD ESPLXME2-LXMM W/ (3) ESPLXMSMI2 48 STATION, TRADITIONALLY -WIRED, COMMERCIAL CONTROLLER.(1) ❑ ESPLXME2 12-STATION, INDOOR/OUTDOOR, PLASTIC WALL -MOUNT 1 ENCLOSURE W/ (3) ESPLXMSMI2 - 12-STATION EXPANSION MODULES. INSTALL IN LXMM POWDER COATED, METAL WALL -MOUNTED CABINET. RAIN BIRD ESPLXME2-LXMM W/ (3) ESPLXMSMI2 48 STATION, TRADITIONALLY -WIRED, COMMERCIAL CONTROLLER.(1) ❑ ESPLXME2 12-STATION, INDOOR/OUTDOOR, PLASTIC WALL -MOUNT 1 ENCLOSURE W/ (3) ESPLXMSMI2 - 12-STATION EXPANSION MODULES. INSTALL IN LXMM POWDER COATED, METAL WALL -MOUNTED CABINET. RAIN BIRD RAINGAUGE ® RAIN SENSOR FOR MAXICOM OR SITECONTROL. CUSTOMIZES WEATHER DATA 1 BY PROVIDING SITE -SPECIFIC RAINFALL MEASUREMENTS, AND SENDING TO CENTRAL CONTROLLER DAILY. RAIN BIRD RAINGAUGE ® RAIN SENSOR FOR MAXICOM OR SITECONTROL. CUSTOMIZES WEATHER DATA 1 BY PROVIDING SITE -SPECIFIC RAINFALL MEASUREMENTS, AND SENDING TO CENTRAL CONTROLLER DAILY. 1 REVISED PER CITY COMMENTS REVISED PER CITY COMMENTS U REVISED PER CITY COMMENTS NC. I REVISION EQUIPMENT SCHEDULE (CONT. PSI SYMBOL MANUFACTURER/MODEL/DESCRIPTION 30 A I WATER METER 1" 30 IRRIGATION LATERAL LINE: PVC SCHEDULE 40 IRRIGATION MAINLINE: PVC SCHEDULE 80 30 PIPE SLEEVE: PVC CLASS 200 SDR 21 Valve Callout 30 Valve Number # # = Valve Flow 30 #" Valve Size 30 30 30 35 35 35 35 35 35 35 35 35 PSI 25 25 25 25 25 25 25 25 25 MJS 7/26/23 HHH SURVEYED: BY OTHERS KEL 9/12/23 HHH DESIGNED: LINDSEY SOLOF/0 KEL I o/1 1/2 HHH DRAWN. DANNY VILLAGRANA CHECKED: LINOSEY 50ZOF/0 BY DATE APPR APPROVED: LINDSEY SOLOF/0 SCALE: VALVE SCHEDULE QTY 1 12,834 L.F. 3,305 L.F. 1,228 L.F. NUMBER MODEL SIZE TYPE GPM WIRE PSI PSI @ POC PRECIP 1 RAIN BIRD EFB-CP 1" SHRUB SPRAY 6.76 35.6 41.5 1.3 in/h 2 RAIN BIRD EFB-CP 1" SHRUB SPRAY 6 35.6 41.4 1.23 in/h 3 RAIN BIRD EFB-CP 1" SHRUB SPRAY 9.44 36.4 42.5 1.48 in/h 4 RAIN BIRD EFB-CP 1" SHRUB SPRAY 22.84 40.9 49.7 5.11 in/h 5 RAIN BIRD EFB-CP 1" SHRUB SPRAY 8.92 37.1 43.2 1.25 in/h 6 RAIN BIRD EFB-CP 1" SHRUB SPRAY 9.92 37.9 44.1 1.4 in/h 7 RAIN BIRD EFB-CP 1" SHRUB SPRAY 7.54 36.6 41.7 1.58 in/h 8 RAIN BIRD EFB-CP 1" SHRUB SPRAY 6.16 36.3 41.3 1.24 in/h 9 RAIN BIRD EFB-CP 1" SHRUB SPRAY 23.88 39.6 47.1 1.66 in/h 10 RAIN BIRD EFB-CP 1" AREA FOR DRIPLINE 12.98 43.3 47.3 0.96 in h 11 RAIN BIRD EFB-CP 1" SHRUB SPRAY 20.44 38.9 46.9 5.12 in/h 12 RAIN BIRD EFB-CP 1" SHRUB SPRAY 13.9 38.0 44.6 4.5 in/h 13 RAIN BIRD EFB-CP 1" TURF SPRAY 25.81 36.0 45.9 1.33 in/h 14 RAIN BIRD EFB-CP 1" TURF SPRAY 9.73 31.2 36.6 1.39 in/h 15 RAIN BIRD EFB-CP 1" TURF SPRAY 3.94 30.2 34.2 2.2 in/h 16 RAIN BIRD EFB-CP 1" SHRUB SPRAY 11.72 36.7 40.5 9.49 in/h 17 RAIN BIRD EFB-CP 1" SHRUB SPRAY 12.55 38.1 42.0 1.74 in/h 18 RAIN BIRD EFB-CP 1" SHRUB SPRAY 11.38 37.8 42.5 1.57 in/h 19 RAIN BIRD EFB-CP 1" SHRUB SPRAY 9.66 37.0 40.6 1.61 in/h 20 RAIN BIRD EFB-CP 1" SHRUB SPRAY 10.34 37.0 40.7 1.79 in/h 21 RAIN BIRD EFB-CP 1" SHRUB SPRAY 24.8 40.1 47.1 1.77 in/h 22 RAIN BIRD EFB-CP 1" TURF SPRAY 9.74 31.0 32.1 2.06 in/h 23 RAIN BIRD EFB-CP 1" SHRUB SPRAY 6.29 36.4 37.1 1.63 in/h 24 RAIN BIRD EFB-CP 1" SHRUB SPRAY 13.33 37.8 40.1 1.83 in/h 25 RAIN BIRD EFB-CP 1" SHRUB SPRAY 19.47 38.6 42.0 2.0 in/h 26 RAIN BIRD EFB-CP 1" SHRUB SPRAY 22.98 40.7 44.5 2.02 in/h 27 RAIN BIRD EFB-CP 1" TURF SPRAY 10.17 32.9 33.1 3.36 in/h 28 RAIN BIRD EFB-CP 1" SHRUB SPRAY 12.33 37.8 38.3 1.84 in/h 29 RAIN BIRD EFB-CP 1" TURF SPRAY 11.95 32.1 32.5 2.71 in/h 30 RAIN BIRD EFB-CP 1" SHRUB ROTOR 6.55 25.8 23.1 0.57 in/h 31 RAIN BIRD EFB-CP 1" AREA FOR DRIPLINE 14.28 45.1 47.4 0.97 in/h 32 RAIN BIRD EFB-CP 1" SHRUB SPRAY 20.43 38.7 41.6 1.78 in/h 33 RAIN BIRD EFB-CP 1" SHRUB SPRAY 18.51 40.4 42.8 1.65 in/h 34 RAIN BIRD EFB-CP 1" SHRUB SPRAY 11.66 37.9 40.1 1.6 in/h 35 RAIN BIRD EFB-CP 1" SHRUB SPRAY 3.29 35.2 36.6 4.81 in/h 36 RAIN BIRD EFB-CP 1" TURF SPRAY 9.07 31.2 33.0 2.73 in/h 37 RAIN BIRD EFB-CP 1" SHRUB SPRAY 14.8 38.7 42.9 1.48 in/h 38 RAIN BIRD EFB-CP 1" SHRUB SPRAY 22.28 40.0 46.2 1.49 in/h 39 RAIN BIRD EFB-CP 1" AREA FOR DRIPLINE 1.76 40.3 43.5 0.93 in/h 40 RAIN BIRD EFB-CP 1" SHRUB SPRAY 15.64 38.2 41.7 4.54 in/h 41 RAIN BIRD EFB-CP 1" SHRUB SPRAY 26 42.7 49.4 2.63 in/h 42 RAIN BIRD EFB-CP 1" SHRUB SPRAY 9.72 37.4 40.2 2.0 in/h 43 RAIN BIRD EFB-CP 1" SHRUB SPRAY 14.56 37.9 40.3 1.88 in/h 44 RAIN BIRD EFB-CP 1" SHRUB SPRAY 25.54 42.8 52.5 1.5 in/h 45 RAIN BIRD EFB-CP 1" TURF SPRAY 17.2 33.4 40.5 1.44 in/h 46 RAIN BIRD EFB-CP 1" SHRUB SPRAY 8.79 36.6 42.7 1.57 in/h 47 RAIN BIRD EFB-CP 1" SHRUB SPRAY 17.96 38.5 43.3 1.54 in/h 48 RAIN BIRD EFB-CP 1" AREA FOR DRIPLINE 14.84 45.7 49 0.96 in/h 49 RAIN BIRD EFB-CP 1" AREA FOR DRIPLINE 10.64 44.6 47.4 0.96 in/h 50 RAIN BIRD EFB-CP 1" AREA FOR DRIPLINE 16.34 43.1 46.7 0.96 in/h 51 RAIN BIRD EFB-CP 1" AREA FOR DRIPLINE 15.96 46.5 50.0 0.96 in/h 52 RAIN BIRD EFB-CP 1" SHRUB SPRAY 23.22 40.7 46.2 1.79 in/h 53 RAIN BIRD EFB-CP 1" TURF SPRAY 5.75 30.4 32.7 3.14 in/h 54 RAIN BIRD EFB-CP 1" SHRUB SPRAY 17.3 39.8 43.5 1.56 in/h 55 RAIN BIRD EFB-CP 1" SHRUB SPRAY 14.57 37.7 40.1 1.82 in/h 56 RAIN BIRD EFB-CP 1" SHRUB SPRAY 30.08 44.4 50.8 2.06 in/h 57 RAIN BIRD EFB-CP 1" TURF SPRAY 24.09 35.9 41.6 1.68 in/h 58 RAIN BIRD EFB-CP 1" SHRUB SPRAY 7.22 36.8 39.3 1.51 in/h 59 RAIN BIRD EFB-CP 1" SHRUB SPRAY 18.76 38.7 43.7 1.44 in/h 60 RAIN BIRD EFB-CP 1" AREA FOR DRIPLINE 21.33 44.5 50.2 0.96 in/h 61 RAIN BIRD EFB-CP 1" SHRUB SPRAY 8.9 37.0 40.5 1.39 in/h 62 RAIN BIRD EFB-CP 1" SHRUB SPRAY 8.22 37.2 40.6 1.24 in/h 63 RAIN BIRD EFB-CP 1" SHRUB SPRAY 9.61 36.5 39.2 1.07 in/h 64 RAIN BIRD EFB-CP 1" SHRUB SPRAY 11.31 38.3 41.2 1.19 in/h 65 RAIN BIRD EFB-CP 1" SHRUB SPRAY 11.28 37.4 38.6 1.88 in/h 66 RAIN BIRD EFB-CP 1" SHRUB SPRAY 12.4 38.1 39.5 1.98 in/h 67 RAIN BIRD EFB-CP 1" SHRUB SPRAY 24.98 40.4 47.6 1.75 in/h 68 RAIN BIRD EFB-CP 1" SHRUB SPRAY 21.64 41.1 46.1 1.59 in/h 69 RAIN BIRD EFB-CP 1" TURF SPRAY 13.68 32.6 35.8 2.2 in/h 70 RAIN BIRD EFB-CP 1" SHRUB SPRAY 6.21 35.7 38.1 1.91 in/h 71 RAIN BIRD EFB-CP 1" SHRUB SPRAY 5.24 35.3 37.6 1.94 in/h 72 RAIN BIRD EFB-CP 1" SHRUB SPRAY 10.67 37.0 39.9 1.63 in/h 73 RAIN BIRD EFB-CP 1" TURF SPRAY 3.32 30.4 32.6 1.53 in/h 74 RAIN BIRD EFB-CP 1" SHRUB SPRAY 8.04 36.5 38.2 1.43 in/h 75 RAIN BIRD EFB-CP 1" SHRUB ROTOR 21.33 31.7 35.8 0.64 in/h 76 RAIN BIRD EFB-CP 1" SHRUB SPRAY 25.58 42.3 48.1 1.54 in/h 77 RAIN BIRD EFB-CP 1" TURF ROTOR 6.88 26.4 27.1 1.25 in/h 78 RAIN BIRD EFB-CP 1" TURF ROTOR 3.91 25.9 26.4 0.56 in/h 79 RAIN BIRD EFB-CP 1" AREA FOR DRIPLINE 19.61 42.5 45.2 0.96 in/h 80 RAIN BIRD EFB-CP 1" TURF SPRAY 2.5 30.2 29.9 1.67 in/h 81 RAIN BIRD EFB-CP 1" TURF SPRAY 8.64 32.1 29.5 2.63 in/h 82 RAIN BIRD EFB-CP 1" SHRUB ROTOR 8.29 26.8 24.2 0.58 in/h 83 RAIN BIRD EFB-CP 1" AREA FOR DRIPLINE 33.54 39.7 44.9 0.96 in/h 84 RAIN BIRD EFB-CP 1" SHRUB SPRAY 10.18 36.3 34.0 3.01 in/h ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: HAD 1983/1991 DATUM C TY OF RENTON t;R Planning/Building/Public Works Dept. PSI CRITICAL ANALYSIS Generated: 2023-07-19 13:31 P.O.C. NUMBER: 01 �1 Water Source Information: O FLOW AVAILABLE Q Water Meter Size: 1" O Flow Available 37.5 GPM N� PRESSURE AVAILABLE N Static Pressure at POC: 56 PSI Elevation Change: 5.00 ft ' 1 Service Line Size: 3" Length of Service Line: 20 ft Pressure Available: 54 PSI V DESIGN ANALYSIS Maximum Station Flow: 33.54 GPM Flow Available at POC: 37.5 GPM Residual Flow Available: 3.96 GPM Critical Station: 44 Design Pressure: 35 PSI Friction Loss: 3.74 PSI Fittings Loss: 0.37 PSI Elevation Loss: 0 PSI Loss through Valve: 3.71 PSI O Pressure Req. at Critical Station: 42.8 PSI C^ Loss for Fittings: 0.0 PSI Loss for Main Line: 0.01 PSI Loss for POC to Valve Elevation: 0 PSI O Loss for Backflow: 5.78 PSI O Loss for Water Meter: 3.87 PSI O Critical Station Pressure at POC: 52.5 PSI Pressure Available: 54 PSI Residual Pressure Available: 1.52 PSI w PC 1 WAS y, CIVIL ENGINEERING NNETr NOTCORE LANDSCAPE ARCHITECTURE o��l PLANNING ° Zw� DESIGN SURVEYING a v 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 `P.04'1' R-425554 �SCAP�P� IN COMPLIANCE WITH CITY OF RENTON STANDARDS CURRENT PLANNING I DEVELOPMENT ENGINEERING AMorganroth [11/16/23] yqi 12/06/2023 W1 T TOWNS ON 12TH 3916 & 3926 N�EY 12TH ST, RENTON, WA 98056 IRRXA 1� S®/ NOTES N DATE: O 01111202J FIELDDO t„ PAGE: DRAWING NO: 14.04 O SHEET: OF: 78 9,3