Loading...
HomeMy WebLinkAboutzR-4264set"qCIVIL CONSTRUCTION PERMIT SW 114, NE 114, SEC. 31, TWP. 23 N., RGE. 5 E., W.M. *1O nl 4 f ? If//l Vi 3 0 T L 7Ao*YP,4 N 510tV 5 PV41 N 5OtV G,4 f?i?tVEf? /W YEf? O Cl TY OF RENTON, WASHINGTON W C4 LEGAL DESCRIPTION SHEET INDEX W HE SOUTH 5.5 ACRES OF HE NORTH 25.5 ACRES OF THAT PORTION OF G'/V/L; Z HE SOUTH HALF OF THE C1.01 TITLE SHEET HORIZONTAL AND VERTICAL CONTROL SHEET NORTHEAST QUARTER OF SECTION 31, TOWiNSHIP 23 NORTH, RANGE 5 Q EAST, WU., IN KING COUNTY, C1.02 BOUNDARY AND TOPOGRAPHIC SHEET �j WASHINGTON, L YING EASTERL Y OF THE SPRINGBROOK ROAD AND L Y/NG C1.03 SITE AND COMPOSITE UTILITY PLAN SOUTHERLY OF HE CARR ROAD, - EXCEPT HAT PORTION L YING EASTERL Y OF A LINE DESCRIBED AS C2 01 TEMPORARY EROSION AND SEDIMENTA TION CONTROL PLAN ' ^ FOLLOWS. C2 31 TESC NOTES AND DETAILS v BEGINNING AT HE EAST QUARTER CORNER OF SAID SECTION 31; C3 01 ROAD AND GRADING PLAN FOUND 0E WITH BRASS PIN IN-*H IN THENCE ALONG THE EAST LINE OF SAID SECTION NORTH 17573" EAST A C321 PARKING LOT PROFILES Z CONCRETE (RENT 229NC HELD i DISTANCE OF 659.00 FEET, C3 31 ROAD AND GRADING DETAILS FOR ROTATION) HENCE ALONG THE NORTH LINE OF SAID 5.5 ACRES NORTH 890028" C4.01 UTILITY PLAN WEST A DISTANCE OF 667.65 FEET TO HE WEST LINE OF A GRAVEL P/T, C4.31 UTILITY DETAILS Z THENCE CONTINUING NORTH 89 00 28 WEST 481.00 FEET TO THE TRUE POINT OF BEGINNING OF SAID Q DESCRIBED LINE,- PERMIT NUMBER THENCE SOUTH 021 '10" WEST 181.16 FEET TO THE SOUP/ LINE OF SAID 5.5 ACRES AND HE TERM/NUS OF CIVIL CONSTRUCTION.' C23002174 SAID DESCRIBED LINE. V) I OWNER/APPLICANT NOTES g0�0 TODD AND POLL Y PROPERTIES, LLC Z 3123 LLG g8055 CON TACT.• POLL Y GARDNER TPN1 -�pt'B Rp S 1. ALL TITLE INFORMATION SHOWN ON THIS MAP HAS BEEN EXTRACTED FROM CHICAGO TITLE O (206) 419-9777 INSURANCE COMPANY GUARANTEE NUMBER 0140333-16 DATED DECEMBER 11, 2018. IN gg30 TP PREPARING THIS MAP, CORE DESIGN, INC. HAS CONDUCTED NO INDEPENDENT TITLE SEARCH _ FOUND 0.5" BRASS PIN IN- N8901'54"W 144.10 ENGINEER SURVEYOR NOR IS CORE DESIGN, INC. AWARE OF ANY TITLE ISSUES AFFECTING THE SURVEYED - / PROPERTY OTHER THAN THOSE SHOWN ON THE MAP AND DISCLOSED BY THE REFERENCED CONCRETE WITH PUNCH IN I I CHICAGO TITLE COMPANY GUARANTEE. CORE DESIGN, INC. HAS RELIED WHOLL Y ON CHICAGO Z CASE DOWN 0.57' CORE DESIGN /NC. °j 12100 NE 195TH ST SUITE TITLE COMPANY'S REPRESENTATIONS OF THE TITLE'S CONDITION TO PREPARE THIS SURVEY Q o _ BOTHELL, WASHINGTON 98011 AND THEREFORE CORE DESIGN, INC. QUALIFIES THE MAPS ACCURACY AND COMPLETENESS TO N eF�so I (- (425) 885-7877 THAT EXTENT. N w s 36 STD 1 4 T " �T 312305-9 69 CONTACT ROBERT D. WEST, P.L.S. - SURVEYOR s 3 L 1 o 3THPL N o� PROJECT L T. cARDNER o I SHERI H. MURATA, P.E. - ENG/VEER 2. THIS SURVEY REPRESENTS V/S/BLE PHYSICAL IMPROVEMENT CONDITIONS EX/STING ON ✓UNE 28, Z Uj SITE r4 12 T 80 O5 R o I _j 2023. ALL SURVEY CONTROL INDICATED AS 'FOUND" WAS RECOVERED FOR THIS PROJECT IN J W N I = I DECEMBER, 2018. SW 41s ST � N I o a Q 6 3� 7305R NT0� L�� SITE I YFOR A TION Y 3. PROPERTY AREA = 26,294f SQUARE FEET (0.6O36f ACRES S 1 �� SE cnRR RD Oo I 8 NERDY CNN i PARCEL N0. 3123059069 4. CONTOUR INTERVAL = 2 FEET •S/T J m = I S 45TH PL -� IFI'2' ADDRESS. 4512 TALBOT RD5. ELEVATION AND OR CONTOUR /NFORUATION SHOWN HEREON /S GENERATED FROM DIRECT NFOUND 0.5" BRASS PIN IN Q I S 47TH ST CONCRETE WITH PUNCH IN CASE E' I I PROPERTY AREA: 26,294 SF 0.60 AC F/ELD OBSERVATION. SAID INFORMATION MEETS US NATIONAL MAPPING STANDARDS AND /S�S 48nl ST o ADOWN 1.02' (RENT 1227 HELD I( ) ACCURATE TO WIHIN ONE-HALF THE CONTOUR INTERVAL. mZ FOR POSITION, EL:154J4) I S 187TH ST nIT �yo1'To"w 691.43 STAPEDI /C"P EXISTING ZONING. CO _ I- _ SiILPE013COfE M853' gi PEB. W/ CAP I 6. BOUNDARY INFORMA TION SHOWN HEREON /S FROM PLA T OF ONE VALLEY PLACE, RECORDED C) su"Pco •case a * � S 51ST ST N N KING COUNTY WASHINGTON, AND MAP NUMBER 301-13 FOUND 4X4 CONCRETE I IN VOLUME 125, PAGE 10, Q MONUMENT WITH 2" BRASS DISC S 45TH PL ® _ _ _ _ _ _ _ _ _ _ _ _ _ _ J SEISM/C DES/GN CATEGORY 02 SPR/NGBROOK ROAD, RECORDED /N COUNCIL'S RECORD VOLUME 23, PAGE 1626. TOPOGRAPHIC S 190TH Sr g Z WITH X IN CASE DOWN 0.36' FOUND 4X4 CONCRETE > >, -� INFORUAT/ON SHOWN HEREON /S RELATED TO HE BOUNDARY BY DIRECT F/ELD OBSERVATION S 53RD PL Q «»� °®� 6 T W/ WA "eP JllB� OLS� !� 14616 - STRUCTURAL DES/GN CR/TER/A: 2015 /BC CH. 1609, ASCE 7-10 CH. 26-30 v10NUMENT WITH 2" BRASS DISC"°" "- �"Pm °°ems' ""`�W"�� - 1 a WITH X WITH CASE DOWN DISC I 3123 R��ON STAMPED COPE 65J FROM CONTROLLING MONUMENTAT/ON. S 192ND ST S 1s2ND ST SE 192ND ST o TNER�Y iN IBC DES/GNATION OF OCCUPANCY GROUP- GROUP B 7. THIS IS A COUB/NED F/ELD TRAVERSE AND GLASS SURVEY. A THREE SECOND COMB/NED ° WEP MEASURE I HE ANGULAR AND DI TANCE RELA TIONSHIPS BETWEN BTHE CONTROLLING T O VICINITY MAP DA TUM UONUUENTA TION AS SHOWN. CL OSURE RA TIOS OF THE TRA VERSE MET OR EXCEEDED THOSE 1 " = 2, 000'f SPECIFIED /N WAC 332-130-090. ALL MEASURING INSTRUMENTS AND EQUIPMENT ARE NA VD88 MAINTAINED /N ADJUSTMENT ACCORD/NG TO MANUFACTURERS SPECIFICA TIONS. aI I 8. UTILITIES OTHER THAN HOSE SHOWN MAY EXIST ON THIS SITE. ONL Y THOSE UTILITIES WITH 0o I ORIGINA TING BEI VCHMA Rif EVIDENCE OF THEIR INS TALLA TION VISIBLE A T GROUND SURFACE OR AS MARKED BY 811 OR FOUND MONUMENT IN TALBOT RD S SHOWN HEREON. RENT1227 EL: 154.74 0HER UTILITY LOCATING PROVIDERS ARE SHOWN HEREON. UNDERGROUND UTILITY PROJECT NO. 18242 HORIZONTAL CONTROL DIAGRAM STRAIGHT LINES BETWEEN PSURFAICE EVIDENCE OFDUTLIT LNOCATIONS BUT MAY CONTAIN AS `t inEKO w 1 " = 50' BENDS OR CURVES NOT SHOWN. SOME UNDERGROUND LOCATIONS SHOWN HEREON MAY��'oF gsy�� • 9 HA VE BEEN TAKEN FROM PUBLIC RECORDS. CLIENT UNDERSTANDS THA T CORE DESIGNo; ASSUMES NO LIABILITY FOR THE ACCURACY OF PUBLIC RECORDS OR PAINTED UTILITY CIVIL ENGINEERING s BASIS OF BEARINGS LOCATIONS. •y �G.on LANDSCAPE ARCHITECTURE =' A'•. �, 41846 a '� PLANNING N050823 E BETWEEN CITY OF RENTON MONUMENTS RENT 1227 AND �o,F Fo/STEO?-,���' SURVEYING RENT 1229 SStONAL �zw�ENG DE S I G N s 10-1�-Z3 72100 NE 795th St, Suite 300 Bothell, Washington 9807 1 425.885.7877 Z UTILITYCONTACTS IN COMPLIANCE WITH CITY OF RENTON STANDARDS ELECTRICITY/NATURAL GAS.' SEWER/WATER PUGET SOUND ENERGY CITY OF RENTON DEVELOPMENT ENGINEERING 19 ESURFACE WATER UTILITY WASTEWATER UTILITY P 0 BOX 97034 Z 1055 S GRADY WAY yqi 11 /07/2023 arah 11 /01 /2023 jstowell 11 /07/2023 LL, SELLEVUE, WASHINGTON 98009 RENTON, WA 98057 1-800-321-7890 425-430-7234 REGIONAL FIRE AUTHORITY eNTc CABLE � �,� WATER UTILITY } � coMcasr APPROVED �4 p c fir/ & ABDOULGAFOURII/Ol/2023 14870 NE 95TH STREET 1 PEDESTRIAN PATH THROUGH PARKING LOT SES 11/9/22 SHM 1� -426401 cthomas 11/01/2023 DATE: WASHINGTON 98052 / / ROW VERTICAL NAVD 1988 ✓AN. 2022 � REDMOND, A 2 CITY COMMENTS SES 6 23 23 SHM SURVEYED: scALE: 1-877-824-2288 HORIZONTAL- NAD 1983/1991 CITY 0 F 3 CITY COMMENTS SES 10 1923 SHM DESIGNED: SHM TITLE SHEET/HORIZONTAL AND FIELDBOOK: RENTON PAGE: TESC SUPERVISOR DRAWN: DATUM SES ONE INCH VERTICAL CONTROL SHEET DRAWING NO: CHECKED: SHM AT FULL SCALE Planning/Building/Public Works Dept. Cl , 01 IF NOT ONE INCH o T.B.D. N0. REVISION BY DATE APPR APPROVED: SCALE ACCORDINGLY SHM SHEET: I OF, 10 LEGEND L ® FOUND MONUMENT, AS NOTED O FOUND PROPERTY CORNER, AS NOTED O SEWER MANHOLE ❑❑ CATCH BASIN TYPE I 0 CATCH BASIN TYPE II O YARD DRAIN ® WATER METER 3D FIRE HYDRANT IRRIGATION METER ® IRRIGATION VALVE UTILITY POLE GUY ANCHOR ® POWER METER - - - -� - - - - -eOWUNtCATION-PEBE-5TAt-- - - - - JUNCTION BOX YARD LIGHT SIGN, AS NOTED - - - - - mcfi ROCKERY CONIFEROUS TREE 0 DECIDUOUS TREE e' PINE MAPLE DECIDUOUS FVC FACE VERTICAL CURB D/W DRIVEWAY WCR WHEELCHAIR RAMP ss SEWER PIPE SD DRAINAGE PIPE W WATER PIPE GAS LINE OHP OVERHEAD POWER cM UNDERGROUND COMMUNICATIONS P UNDERGROUND POWER X FENCE LINE I I I N89°01'20"W 691.43 - - FOUND 4X4 CONCRETE MONUMENT WITH 2" BRASS DISC WITH X IN CASE DOWN 0.36' I 2 I I ad CB 8032 TYPE I RIM EL=148.75 6"CONC(S)IE=146.50 a 0 ° a ♦ a � I FOUND 0.5" BRASS PIN IN CONCRETE WITH PUNCH IN 0.57' FOUND 0.5" BRASS PIN INJ ' CONCRETE WITH PUNCH IN j CASE (RENT 1229, HELD FOR ROTATION) I I I I I I I I I I I I I I I I I I I a I I I I N I � ° CB 18073. TYPE I RIM EL=148.80 c� I 12"CMP(S)IE=145.45 18"CONC(N)IE=145.40 I I I CB 8072 TYPE I v RIM EL=148.60 4"PVC(S)IE=146.59 ? 4"PVC(W)IE=146.53 ° I 4. I ® rn °-------------- 4.4 30.00- ss ? FVC _9010 TP CF T1230 A BOTpas 98055 R BUILDING 4430 TP�gO C"8146, TYPE I RIM EL=156.68 4"PVC(NE)IE=155.45 6"CPEP(E)IE=154.77 4"CPEP(N)IE=154.70 4"CPEP(N)IE=154.55 12"CMP(S)IE=154.53 N89 0154 "W �44.10 c' X vBF o.1 X I SSMH 18074 RIM EL=150.37 I PER ASBUILTS DECK WITH STAIRS 8"PVC(S)IE=145.17 i L. ....... 8"PVC(W)IE=139.02 I SDMH I8147. TYPE II 12"PVC(S)IE=138.72 I RIM EL=157.10 ONE STORY WOOD 12"PVC(N)IE=138.62 i 36"CMP(S)IE=151.70 FRAMED BUILDING I I o I U) ° I ° °FCONC BLOCK WALL d I � ° SIGN FOR "SWANSON I NO PARKING GARDNER ATTORNEY i 3 10 I SDMH 7003 TYPE II d TPN: 312305-9069 o AT LAW"° i RIM EL=159.04 I T. GARDNER 6"PVC(S)IE=155.19 4512 TALBOT RD S 8"CMP(W)IE=151.64 BRICK COLUMN I :d 98055 I SDMH 8148 TYPE II P d c� I I 8"CMP(E)IE=151.64 IT, �� RIM EL=158.93 ? s D i 36"CMP(N)IE=151.48 3 SD s 8"CMP(W)IE=151.28 p d. N CB 8095 TYPE I RIM EL=152.74 ............. 8"CMP(E)IE=151.2 8"CMP(W)IE=151.16 � I 10' ROADWAY & 8 ° j UTILITIES EASEMENT II 3 1 I REC. NO. 8610311897 m ASPHALT I i V) �1,4 16 '�.. ,.. ° I RAMP I I 00 BUILDING OVERHANG Ur I I Q0 a i fj SD 3 CB 7004, TYPE I SDCO I / I RIM EL=159.96 RIM EL=162.02;F ON TOP E I I YD 7011, TYPE 6"PVC(E)IE=156.41 6"PVC(E)IE=158.001 .... RIM 7011EL=TYP .94 6"PVC(N)IE=156.21 6"PVC(N)IE=158.00 4"PVC E IE=161.24 APPR)X. SIDE SEWER4"PVC(W)IE=161.24 LINE PER ASBUILTS d TREE DRIPLINE (TV.) FOUND 0.5" BRASS PIN IN j I I CONCRETE WITH PUNCH IN CASE I I a CONC BLOCK WALL DOWN 1.02' (RENT 1227 HELD I SD SD sD I SET REBAR W/ S 45TH PL FOR POSITION, EL:154.74) 3 I N` i STAMPED " 4 RIM EL=164.40 VERHANG SD SECURITY p :•. SSMH 11269 V STREET SIGN, 6"PVC E IE-158.38 CAMERA IN USE - I ---- - ----- O-------- ---- -- RIM EL=166.75 6.26 �......•. NO PARKIN 6"PVC(N)IE=158.38�111275, TYPE I---------------- 8 - - - ------ -- 6"PVC(NE)IE=158.38 RIM EL=161.46 FOUND 4X4 CONCRETE SS- I ss SD SD SD p SD MONUMENT WITH 2" BRASS DISC cSSMH PE ASBUILT - � - - - - - - - - W 0 31 WEA NE �Y YD #7015, TYPE I RIM EL=162.12 4"PVC(N)IE=161.27 4"PVC(E)IE=161.22 SET REBAR W/ CAP STAMPED "CORE 446 7'--r------ - Ss - - - - - - - - - - - - - - - - - - - D/W '- _ _ H 3 0 1 d! OHP OHP 0 P OHP W OHP W OHP W JAL FS oo N89 0154 "W 146.16 p� p a d FOUND REBAR 26.6' - SET_NAIL W/ WASHER S LINE OF THE S 5.5 ACRES OF THE N 25.5 W OF PROPERTY - - - STAMPED ' TORE 44653 - - - - - - -AC?LY- QFL TRAT-R=044 OFL Z�/f-S-HA4F-pF THE CORNER NE QUARTER OF SEC 31-23-5 I oHP P 20' ROADWAY EASEMENT 90 00 L_ o CB 8091 TYPE I 31230 RENTO RIM EL=156.16 REC. NO. 5973181 TPN: 1NN'I ° 54.79 12 PVC(SI)IE 1154 7 .0* 1 fP(N)Ifk-154,,11 SSMH #8213 RIM EL=156.76 12"PVC(S)IE=146.21 12"PVC(N)IE=146.06 1 PEDESTRIAN PATH THROUGH PARKING LOT SES 11/9/22 SHM 2 CITY COMMENTS SES 6 23 23 SHM SURVEYED: RDW SCALE` 3 CITY COMMENTS SES 10 1923 SHM DESIGNED: DRAWN: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY CHECKED: SHM NO. REVISION BY DATE AP P R APPROVED: SHM I I I I I I I 3 W � 3 � � I I J I I 9094 PLC GNTON 11 � I I I I I I I SET NAIL WASHER STAMPED COff 44653 _ 10' ELECTRIC LINE EASEMENT REC. NO. 6023496 VERTICAL DATUM NAVD88 ORIGINATING BENCHMARK FOUND MONUMENT IN TALBOT RD S SHOWN HEREON. RENT1227 EL: 154.74 BASIS OF BEARINGS A SCALE: 1 " = 20' 0 10 20 40 N05°08'23"E BETWEEN CITY OF RENTON MONUMENTS RENT 1227 AND RENT 1229 REFERENCES 1. PLAT OF ONE VALLEY PLACE, RECORDED IN VOLUME 125, PAGE 10, KING COUNTY, WASHINGTON. 2. MAP NUMBER 301-13 SPRINGBROOK ROAD, RECORDED IN COUNCIL'S RECORD VOLUME 23, PAGE 1626. LEGAL DESCRIPTION THE SOUTH 5.5 ACRES OF THE NORTH 25.5 ACRES OF THAT PORTION OF THE SOUTH HALF OF THE NORTHEAST QUARTER OF SECTION 31, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., IN KING COUNTY, WASHINGTON, LYING EASTERLY OF THE SPRINGBROOK ROAD AND LYING SOUTHERLY OF THE CARR ROAD; EXCEPT THAT PORTION LYING EASTERLY OF A LINE DESCRIBED AS FOLLOWS: BEGINNING AT THE EAST QUARTER CORNER OF SAID SECTION 31; THENCE ALONG THE EAST LINE OF SAID SECTION NORTH 11513" EAST A DISTANCE OF 659.00 FEET; THENCE ALONG THE NORTH LINE OF SAID 5.5 ACRES NORTH 89'00'28" WEST A DISTANCE OF 667.65 FEET TO THE WEST LINE OF A GRAVEL PIT; THENCE CONTINUING NORTH 89°00'28" WEST 481.00 FEET TO THE TRUE POINT OF BEGINNING OF SAID DESCRIBED LINE; THENCE SOUTH 0*2110" WEST 181.16 FEET TO THE SOUTH LINE OF SAID 5.5 ACRES AND THE TERMINUS OF SAID DESCRIBED LINE. RESTRICTIONS 1. THIS SITE IS SUBJECT TO A ROADWAY EASEMENT AS DISCLOSED BY INSTRUMENT RECORDED UNDER RECORDING NUMBER 5973181 AND MODIFIED UNDER RECORDING NUMBER 20190830000759. (SHOWN HEREON) 2. THIS SITE IS SUBJECT TO AN ELECTRIC LINE EASEMENT AS DISCLOSED BY INSTRUMENT RECORDED UNDER RECORDING NUMBER 6023496. (SHOWN HEREON) 3. THIS SITE IS SUBJECT TO A ROADWAY AND PUBLIC UTILITIES EASEMENT AS DISCLOSED BY INSTRUMENT RECORDED UNDER RECORDING NUMBER 8610311891. (SHOWN HEREON) 4. THIS SITE IS SUBJECT TO A PSE UTILITY EASEMENT AS DISCLOSED BY INSTRUMENT RECORDED UNDER RECORDING NUMBER 20190926000715. (FOLLOWS PSE FACILITIES AS CONSTRUCTED, NOTHING TO PLOT) NOTES 1. ALL TITLE INFORMATION SHOWN ON THIS MAP HAS BEEN EXTRACTED FROM CHICAGO TITLE INSURANCE COMPANY GUARANTEE NUMBER 0140333-16 3RD REVISION DATED JULY 26, 2023. IN PREPARING THIS MAP, CORE DESIGN, INC. HAS CONDUCTED NO INDEPENDENT TITLE SEARCH NOR IS CORE DESIGN, INC. AWARE OF ANY TITLE ISSUES AFFECTING THE SURVEYED PROPERTY OTHER THAN THOSE SHOWN ON THE MAP AND DISCLOSED BY THE REFERENCED CHICAGO TITLE COMPANY GUARANTEE. CORE DESIGN, INC. HAS RELIED WHOLLY ON CHICAGO TITLE COMPANY'S REPRESENTATIONS OF THE TITLE'S CONDITION TO PREPARE THIS SURVEY AND THEREFORE CORE DESIGN, INC. QUALIFIES THE MAP'S ACCURACY AND COMPLETENESS TO THAT EXTENT. 2. THIS SURVEY REPRESENTS VISIBLE PHYSICAL IMPROVEMENT CONDITIONS EXISTING ON JUNE 28, 2023. ALL SURVEY CONTROL INDICATED AS "FOUND" WAS RECOVERED FOR THIS PROJECT IN DECEMBER, 2018. 3. PROPERTY AREA = 26,294t SQUARE FEET (0.6036t ACRES). 4. CONTOUR INTERVAL = 2 FEET. 5. ELEVATION AND/OR CONTOUR INFORMATION SHOWN HEREON IS GENERATED FROM DIRECT FIELD OBSERVATION. SAID INFORMATION MEETS US NATIONAL MAPPING STANDARDS AND IS ACCURATE TO WITHIN ONE-HALF THE CONTOUR INTERVAL. 6. BOUNDARY INFORMATION SHOWN HEREON IS FROM PLAT OF ONE VALLEY PLACE, RECORDED IN VOLUME 125, PAGE 10, KING COUNTY, WASHINGTON, AND MAP NUMBER 301-13 SPRINGBROOK ROAD, RECORDED IN COUNCIL'S RECORD VOLUME 23, PAGE 1626. TOPOGRAPHIC INFORMATION SHOWN HEREON IS RELATED TO THE BOUNDARY BY DIRECT FIELD OBSERVATION FROM CONTROLLING MONUMENTATION. 7. THIS IS A COMBINED FIELD TRAVERSE AND GNSS SURVEY. A THREE SECOND COMBINED ELECTRONIC TOTAL STATION AND GNSS UNIT WITH WSRN CORRECTIONS WERE USED TO MEASURE THE ANGULAR AND DISTANCE RELATIONSHIPS BETWEEN THE CONTROLLING MONUMENTATION AS SHOWN. CLOSURE RATIOS OF THE TRAVERSE MET OR EXCEEDED THOSE SPECIFIED IN WAC 332-130-090. ALL MEASURING INSTRUMENTS AND EQUIPMENT ARE MAINTAINED IN ADJUSTMENT ACCORDING TO MANUFACTURER'S SPECIFICATIONS. 8. UTILITIES OTHER THAN THOSE SHOWN MAY EXIST ON THIS SITE. ONLY THOSE UTILITIES WITH EVIDENCE OF THEIR INSTALLATION VISIBLE AT GROUND SURFACE OR AS MARKED BY 811 OR OTHER UTILITY LOCATING PROVIDERS ARE SHOWN HEREON. UNDERGROUND UTILITY LOCATIONS SHOWN ARE APPROXIMATE ONLY. UNDERGROUND CONNECTIONS ARE SHOWN AS STRAIGHT LINES BETWEEN SURFACE EVIDENCE OF UTILITY LOCATIONS BUT MAY CONTAIN BENDS OR CURVES NOT SHOWN. SOME UNDERGROUND LOCATIONS SHOWN HEREON MAY HAVE BEEN TAKEN FROM PUBLIC RECORDS. CLIENT UNDERSTANDS THAT CORE DESIGN ASSUMES NO LIABILITY FOR THE ACCURACY OF PUBLIC RECORDS OR PAINTED UTILITY LOCATIONS. PROJECT NO. 18242 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 1-31-23 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING yq i 11 /07/2023 UR R-426402 DATE: HORIZZOONnTAU NAD 1983/1991 AIIOM& CITY OF ✓AN. 2022 PRI FIELDBOOK: RENTON DATUM BOUNDARY AND TOPOGRAPHIC SHEET DRAWING NO: Planning/Building/Public Works Dept. cl.02 SHEET: 2 OF: 10 011. ^ ` N cn O �02 J 0 N N M O 0 M N V 9 S 45TH PL I 0 0 0 2 0 0 0 0 0 0 0 II i 2 G' /-'turn//VU yu/ 20' 4512 TALBOT RD S 10 ROADWA Y AND STORM 98055 UTl IAf-5 EASEMENT T ��� �y �, ° WHEEL STOP RE . NO.. 9610311897 I f (TYPE L =3 o0 16 AD SE S, 433 SF COURTYARD - 4 ��_ SEE LANDSCAPE PLANS c� EXISTING ROW TREES cc m I I I 6 EXISTING CURB TO BE REMOI/ED ' I B/KE STORA I / _5 7 ``� RELOCATE REFUSE LOCATED IN yy� � � y y PEDESTR/AN :. a • s .. AND RECYCLE THE BUILDIti �5 PA TH ;sa. ,. LANDSCAPE AREA i PROPOSED PARKING 361 SF LOT EXPANS/ON 9 a PROPOSED STORM CONNECTION I 10 - REMOI/E THE EX SPLASH BLOCK VERIFY EX SIDE SEWER/ AND CONNECT TO THE STORM C EXIST/NG TREE 7.7 Q, (NOT //V ASBUIL TSB TO BE REMOI/ED s S.CONNECT AREA DRAIN o R DUMPS1 R TO THE X/STING SIDE SEWER � L 777, PROTECT EXISTING TRANSFORMER L 18 T INSTALLED BY WEATHERL Y INN PROJECT DURING CONSTRUCTION I LANDSCAPE Vol V , , /— l� BUFiZR — — — 0 OHP —OH OHP OHP OHP / W W Wvv N 01 '54 "W 146.16FE REPLACE GRATE WITH SOLID o so — -- - -- — — —- LID AND COVER WITH _ CONNECT TO CONCRETE P 0 W h ST RM RELOCATED REFUSE o ECYCLE _ IT 0 a V a WEATHERL YINN o I I a a. 1 PEDESTRIAN PATH THROUGH PARKING LOT SES 11/9/22 SHM 2 CITY COMMENTS SES 6/23/23 SHM SURVEYED: ROW SCALE: 3 CITY COMMENTS SES 10 1923 SHM DESIGNED: SHM DRAWN: SES ONE INCH CHECKED: SHM AT FULL SCALE IF NOT ONE INCH N 0 . REVISION BY DATE AP P R APPROVED: / SCALE ACCORDINGLY EXISTING SPLASH BLOCK VERTICAL: NAVE) 1988 HORIZONTAL- NAD 1983/1991 DATUM SCALE: 1" = 20' 0 10 20 40 PARKING PARKING STALL SIZE LENGTH = 18' 0 "PARK/NG DEPTH CAN BE REDUCED TO 18' WITH 2' OF CAR HANG OVER WIDTH = 9' O„ ADA PARKING STALL SIZE LENGTH= 20' 0" WIDTH= 8' 0" ACCESS WIDTH= 5' 0" A MIN/MUM OF 2.0 PER 1, 000 SQUARE FEET OF NET FLOOR AREA AND MAX/MUM OF 4.5 PARKING SPACE PER 1, 000 SQUARE FEET OF NET FLOOR AREA. 6,082 SF OF BUILDING STRUCTURE 12 PARKING STALLS M/N 27 PARKING STALLS MAX. 15 STANDARD STALLS 2 COMPACT (8.5' W/DE) 17 STALLS TOTAL SITE STA TIS TICS COMMERCIAL OFFICE FRONT SETBACK - '1'-0" BUILDING LESS THAN 25' HT. REAR YARD - 0' SIDE YARD - 0' MIN. LOT SIZE - 25, 000 50 FT LOT AREA 26,294 50 FT HEIGHT LIMIT 250' ABOI/E AVERAGE BUILDING EL -VA TION IMPERIOUS SURFACE 757 MAX OF GROSS LOT AREA NEW IMPERVIOUS SURFACE (PARKING) 3, 866 SO FT BUILDING COVERAGE 659 OF TOTAL LOT AREA 26,294 SO FT X .65 17, 09 1. 1 SO FT MAX TOTAL BUILDING COVERAGE 6,102 SO FT EXISTING / 239 TOTAL BUILDING COVERAGE 0 y�IDEKO� pF WAsy�,'cy?, off•,. �,F 41846 ,, *- 0 G/STER, ��. FSS�ONAL ENG� 10-1�-Z3 PROJECT NO. 18242 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING DESIGN SURVEYING 7 2100 NE 7 95th St, Suite 300 Bothell, Washington 9807 1 425.885.7877 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING ` yqi 11 /07/2023 %,�# R-426403 CITY OF RENT 0 N SITE AND COMPOSITE UTILITY PLAN Planning/Building/Public Works Dept. DATE: JAN. 2022 PAGE: C1. 03 SHEET: 3 OF: 10 9 4 S 45TH PL O 1a TO Q r) I I CB 8032 TYPE I i \ RIM EL=148.75 6"CONC(S)IE=146.50 i a � 0 I I� I 1 I d I a ' I o FOUND 0.5" BRASS PINT IN CONCRETE WITH PUNCH IN / \ CASE DOWN 0.57' ss Ia � 9010 305- TPN TP B0� �_S 9,3055 OcTALgo� RO BUILDING 443 CB 8146 TYPE I RIM EL_f 6.68 4"PVC(NE)IE=155.45 ' 6"CPEP(E)IE=154.77,. 4"CPEP(N)IE=154.70 �j 4"CPEP(N)IE=154.55 12"CMP(S)IF7=154.53 VBF N89°01'54"W 144,10 - - - - I �fOU I o d Z1 T \ `SMSMH 8074 II R T/NG DRIVf_WA Y AS EI_5it ASBUILTO f 6 ` VC(S)IE=1 5.1, s-y 'UCTION DR//EWAY W 8"PVC(W)IE=l39.02 / SDMH #8147, TYPE II / 12"PVC(S)IE- 138.72 RIM EL=157.10 N IE=138.62 36"CMP(S)IE=151.70 S s REMOVE �\ I EXISTING CURB p � W ° d C NC OCK WALL II (jYP) a I a ad. SIGN FOR "SWANSON PARKING EX/STING PARKING ,. GARDNER ATTORNE" AT LAIAi" SDMH 7003, TYPE II TO REMAIN TCH BASIN INSERT PER / I I RIM EL=159.04 O.R. STD PLAN 216.30 I `� 16"PVC(S)IE=155.19 I BRICK COLUMIJ 12 SHEET C2.31 (TYPE U �� a I 8"CMP(W)IE=151.64 SDM 8148, TYPE 11 8"CMP(E)IE=151.64 / = d I''1� I RIM EL=158.93 / 36"CMP(N)IE=151.48 D 1 SD I I II \8"CMP(W)IE=151.28 G�6 5 a s9 p� CB 8095 TYPE I RIM EL=l52.74 c� EXISTING ROW TREES - �. 8"CMP(E)IE=151.24 4 TO BE REMAIN .....8.."CMP W IE-151.16 II 10' ROADWAY I & UTILITIES EASEMENT S� m i I B I �°2 REC. NO. 86103�897 �I J I O � - - ASPHALT w I u, I ,15 a,. i `� / I I RAMP / RIM EL=148.80 12"CMP(S)IE=145.45 18"CONC(N)IE=145.40 CB 8072 TYPE I .U) RIM EL=148.60 4"PVC(S)IE=146.59 4" PVC(W)IE=l 46.53 Q, a,.. d� > C .. , /- FVC ECK WITH STAIRS ONE STORY WOOD / FRAMED BUILDING I I I TPN: 312305-9069 T. GARDNER 4512 TALBOT RD S 98055 00 BUILDING OVERHA w / °i 7II d I DISTURBED AREA 15,024 SF (0.34 AC� ° I SD I CBI 7004, TYP SDCO� RIM EL-159196 RIM EL=162.023E ON OR \ YD 7011, TYPE I p I 6"PVC(E)IE=156,.41 6 PVC(E)IE=158.001 ..., ss RIM EL=161.94 .... L,...a CPVC(N)IE=15 .21 6"PVC(N)IE=158.00 4"PVC(E)IE=161.24 P w C. N O CD Z I EXISTING ROCKERY EXISTING BUILDING 7 9094 Ic 1PN 3� NN SRENTON L WEA�HER�Y I I I I I G I APPROX. SIDE SEWER. I I ss q 4"PVC(W)IE=161.24 - I YD 7015, TYPE I LINE PER ASBUILTS d I DRIP INE (TYP.)_ RIM EL=162.12 FOUND 0.5" BRASS PIN IN�I I� 11I 4"PVC(N)IE=161.27 1CONCRETE WITH PUNCH IN CASE ONG LOCK WALL /4"PVC(E)IE=161.22 DOWN 1.02' (RENT 1227 HELD SE REBAR W/ CAP I SDCO SD D / sD I FOR POSITION, EL:154.74) ST MPED "CORE 4 SD I I RIM EL=164.40 RHANG SECURITY- P '- / SET REBAR W CAP � � SSMH 11269 / STREET SIGN, / VC E IE-158.38 CAMERA IN USE --- --- ---- O - -__s- - RIM EL-166.75 STAMPED "CORE 4465 r i........ NO PARKIN \ 6' C(N)IE=158.38 CB 11275 TYPE---------------L----- -- -------- --- --- �° / \ 6" V (N 8.38 RIM EL-161.46 % \ FOUND 4X4 CONCRETE - - MONUMENT WITH 2" BRASS DISC cSSMH PER ASBUILT o �, d. G - - PROTECT EX - y DEW ,1 TRANSFORMER -� - - - - - - - - - - - - - - - - o r� - /"P - _ OH DURING 9°01'54"W 146.1 P w rH -� S 0. oo CONSTRUC/ON IJ .4a � � S LINE OF THE S 5.5 AC S OF THEN 25.5 ACRES OF THAT FOUND REBAR 26.6' - SET_NAIL W/ WASHER PORTION OF THE S HALF OF HE NE QUARTER OF SEC 31-23-5 >�:EE \ I d < CORNERROPERTY - - - STAMPED "CORE 44653 - - - - �� I ' / P P off . CB 8091 TYPE 20' ROADWAY EASEMENT 31230jRENTpN LUcl RIM EL-15616 REC. NO. 5973181 N: NNE �I Y 4"PVC(E)IE=154.79 12"PVC(S)IE=154.17 12"CMP(N)IE=l54.11 SSMH 8213 RIM EL=156.76 12"PVC(S)IE-146.21 12"PVC(N)IE=146.06 I cY I EX/STING TREE NEAiNER I------� / TO REMOI/ED S/Z T FENCE PER C. O.R. STD PLAN 214.00 / SHEET C2.31 1 PEDESTRIAN PATH THROUGH PARKING LOT SES 11/9/22 SHM 2 CITY COMMENTS SES 6/23/23 SHM SURVEYED: RDW 3 CITY COMMENTS SES 10 1923 SHM DESIGNED: SHM DRAWN: SES CHECKED: SHM NO. REVISION BY DATE APPR APPROVED' SHM _SS - - - SET NAIL W/ WASHER _ _ STAMPED "CORE 44653 10' ELECTRIC LINE EASEMENT REC. NO. 6023496 SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL• NAVD 1988 HORIZONTAL- NAD 1983/1991 DATU M L_ F I I I IH PE ASB I _J SCALE: 1" = 20' 0 10 20 40 CONSTRUCT/ON SEQUENCE 1. SCHEDULE A PRECONSTRUCTION CONFERENCE W/TH THE CITY DEl/ELOPMENT ENGINEER. ONCE THE MEETING /S HELD THE CIWZ CONSTRUCTION PERMIT W/LL BE ISSUED. 2. FLAG THE LIMITS OF CLEARING, INSTALL CATCH BASIN INLET PROTECTION ON EXISTING CBS AND INSTALL PRO TEC77Vf- SILT FENCING WHERE INDICATED. 3. POST SIGN W/TH NAME AND PHONE NUMBER OF ESC SUPER �150R. 4. REMOI/E THE EXISTING CURB AS SHOWN ON THIS SHEET. 5. ROUGH GRADE THE PARKING LOT. 6. INSTALL PROPOSED STORM, PROTECT FROM S/L TA TA T/ON AND CONNECT TO EXISTING STORM. 7. CONSTRUCT THE REMAINING STORM DRAINAGE FACILITIES PER THE ROAD & STORM DRAINAGE PLANS. PROTECT THESE FACIL/TIES FROM DAMAGE AND S/L TA 7ON DURING CONSTRUCTION. INSTALL INLET PROTECTION. F/NE GRADE PARK/NG LOT AND INSTALL PROPOSED CURB. 8. PA Vf- PARKING L OT 9. HYDROSEED ANY REMAINING DISTURBED SURFACES. REMOI/E ALL TEMPORARY FACILITIES. PUMP ANY COLLECTED DEBRIS FROM STORM DRAINAGE SYSTEM. R-426404 CITY OF RENTON Planning/Building/Public Works Dept. PROJECT NO. 18242 t �IDEKO ,� pF N'ASy�,'cy?, Z; CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING o�o�Fssc/STE DESIGN TONAL EN SURVEYING 10-1�-Z3 72100 NE 795th St, Suite 300 Bothell, Washington 9807 1 425.885.7877 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING 10 yqi 11 /07/2023 DATE: ✓AN° 2022 TEMPORARY EROSION AND PAGE: SEDIMENT CONTROL PLAN DRAWING NO: cz. of SHEET: 4 OF: 10 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 EROSION AND SEDIMENT CONTROL (ESC) STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE EROSION AND SEDIMENT CONTROL (ESC) PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE ESC STANDARD PLAN NOTES. 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANT'S CONTRACTOR. 2. THE APPLICANT IS RESPONSIBLE FOR OBTAINING THE WASHINGTON STATE DEPARTMENT OF ECOLOGY (ECOLOGY) CONSTRUCTION STORMWATER GENERAL PERMIT, IF IT IS REQUIRED FOR THE PROJECT. THE APPLICANT SHALL PROVIDE THE CITY COPIES OF ALL MONITORING REPORTS PROVIDED TO ECOLOGY ASSOCIATED WITH THE CONSTRUCTION STORMWATER GENERAL PERMIT, 3. THE ESC PLAN SET SHALL INCLUDE AN ESC CONSTRUCTION SEQUENCE DETAILING THE ORDERED STEPS THAT SHALL BE FOLLOWED FROM CONSTRUCTION COMMENCEMENT TO POST -PROJECT CLEANUP IN ORDER TO FULFILL PROJECT ESC REQUIREMENTS. 4. THE BOUNDARIES OF THE CLEARING LIMITS SENSITIVE AREAS AND THEIR BUFFERS AND AREAS OF VEGETATION PRESERVATION AND TREE RETENTION AS PRESCRIBED ON THE PLAN(S) SHALL BE CLEARLY DELINEATED BY FENCING AND PROTECTED IN THE FIELD IN ACCORDANCE WITH APPENDIX D OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM) PRIOR TO THE START OF CONSTRUCTION. DURING THE CONSTRUCTION PERIOD, NO DISTURBANCE BEYOND THE CLEARING LIMITS SHALL BE PERMITTED. THE CLEARING LIMITS SHALL BE MAINTAINED BY THE APPLICANT/ESC SUPERVISOR FOR THE DURATION OF CONSTRUCTION. 5. STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINNING OF CONSTRUCTION AND MAINTAINED FOR THE DURATION OF THE PROJECT. ADDITIONAL MEASURES, SUCH AS CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE REQUIRED TO ENSURE THAT ALL PAVED AREAS ARE KEPT CLEAN AND TRACK -OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR FOR THE DURATION OF THE PROJECT. IF SEDIMENT IS TRACKED OFFSITE, PUBLIC ROADS SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY, OR MORE FREQUENTLY DURING WET WEATHER, AS NECESSARY TO PREVENT SEDIMENT FROM ENTERING WATERS OF THE STATE. 6. WASHOUT FROM CONCRETE TRUCKS SHALL BE PERFORMED OFF -SITE OR IN DESIGNATED CONCRETE WASHOUT AREAS ONLY. DO NOT WASH OUT CONCRETE TRUCKS ONTO THE GROUND, OR TO STORM DRAINS OR OPEN DITCHES. ON -SITE DUMPING OF EXCESS CONCRETE SHALL ONLY OCCUR IN DESIGNATED CONCRETE WASHOUT AREAS. 7. ALL REQUIRED ESC BMPS SHALL BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING AND/OR CONSTRUCTION TO PREVENT TRANSPORTATION OF SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL ESC BMPS SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARING AND/OR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON -SITE EROSION HAS PASSED. ALL ESC BMPS SHALL BE REMOVED AFTER CONSTRUCTION IS COMPLETED AND THE SITE HAS BEEN STABILIZED TO ENSURE POTENTIAL FOR ON -SITE EROSION DOES NOT EXIST. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT, ENHANCEMENT, AND REMOVAL OF ESC BMPS SHALL BE THE RESPONSIBILITY OF THE APPLICANT. 8. ANY HAZARDOUS MATERIALS OR LIQUID PRODUCTS THAT HAVE THE POTENTIAL TO POLLUTE RUNOFF SHALL BE DISPOSED OF PROPERLY. 9. THE ESC BMPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE APPLICANT SHALL ANTICIPATE THAT MORE ESC BMPS WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE APPLICANT TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL ESC BMPS, OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM. 10. APPROVAL OF THIS PLAN IS FOR ESC ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICTORS, CHANNELS, OR STORMWATER FACILITIES. 11. ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES SHALL BE SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL. 12. ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCTOBER 1 ST THROUGH APRIL 30TH) OR SEVEN DAYS DURING THE DRY SEASON (MAY 1ST THROUGH SEPTEMBER 30TH) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC COVER METHODS (E.G., SEEDING, MULCHING, PLASTIC COVERING, ETC.) IN CONFORMANCE WITH APPENDIX D OF THE RENTON SWDM. 13. WET SEASON ESC REQUIREMENTS APPLY TO ALL CONSTRUCTION SITES BETWEEN OCTOBER 1 ST AND APRIL 30TH, UNLESS OTHERWISE APPROVED BY THE CITY. 14. ANY AREA NEEDING ADDITIONAL ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN SEVEN (7) DAYS. 15. THE ESC BMPS ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED AT A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT. INSPECTION AND MAINTENANCE SHALL OCCUR MORE FREQUENTLY AS REQUIRED BY THE CITY. 16. BEFORE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY CATCH BASIN INSERTS PER THE CITY STANDARD PLAN 216.30 SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE INLET WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. ALL CATCH BASIN INSERTS SHALL BE PERIODICALLY INSPECTED AND REPLACED AS NECESSARY TO ENSURE FULLY FUNCTIONING CONDITION. 17. AT NO TIME SHALL SEDIMENT ACCUMULATION EXCEED 2/3 OF THE CAPACITY OF THE CATCH BASIN SUMP. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT -LADEN WATER INTO THE DOWNSTREAM SYSTEM. 18. ANY PERMANENT STORMWATER FACILITY LOCATION USED AS A TEMPORARY SETTLING BASIN SHALL BE MODIFIED WITH THE NECESSARY ESC BMPS AND SHALL PROVIDE ADEQUATE STORAGE CAPACITY. IF THE TEMPORARY FACILITY IS TO ULTIMATELY FUNCTION AS AN INFILTRATION SYSTEM IN ITS PERMANENT STATE, THE TEMPORARY FACILITY SHALL BE ROUGH GRADED SO THAT THE BOTTOM AND SIDES ARE AT LEAST THREE FEET ABOVE THE FINAL GRADE OF THE PERMANENT FACILITY, 19. AREAS DESIGNATED ON THE PLAN(S) CONTAINING EXISTING STORMWATER FACILITIES OR ON -SITE BMPS (AMENDED SOILS, BIORETENTION, PERMEABLE PAVEMENT, ETC.) SHALL BE CLEARLY FENCED AND PROTECTED USING ESC BMPS TO AVOID SEDIMENTATION AND COMPACTION DURING CONSTRUCTION. 20. PRIOR TO THE BEGINNING OF THE WET SEASON (OCTOBER 1ST), ALL DISTURBED AREAS SHALL BE INSPECTED TO IDENTIFY WHICH ONES SHALL BE SODDED OR SEEDED IN PREPARATION FOR THE WINTER RAINS. DISTURBED AREAS SHALL BE SODDED OR SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON. AN EXHIBIT OF THOSE AREAS TO BE SODDED OR SEEDED AND THOSE AREAS TO REMAIN UNCOVERED SHALL BE SUBMITTED TO THE CITY FOR REVIEW. 21, PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, THE PROJECT SITE SHALL BE STABILIZED TO PREVENT SEDIMENT -LADEN WATER FROM LEAVING THE PROJECT SITE, ALL ESC BMPS SHALL BE REMOVED, AND STORMWATER CONVEYANCE SYSTEMS, FACILITIES, AND ON -SITE BMPS SHALL BE RESTORED TO THEIR FULLY FUNCTIONING CONDITION. ALL DISTURBED AREAS OF THE PROJECT SITE SHALL BE VEGETATED OR OTHERWISE PERMANENTLY STABILIZED. AT MINIMUM DISTURBED AREAS SHALL BE SODDED OR SEEDED AND MULCHED TO ENSURE THAT SUFFICIENT COVER WILL DEVELOP SHORTLY AFTER FINAL APPROVAL. MULCH WITHOUT SEEDING IS ADEQUATE FOR AREAS TO BE LANDSCAPED BEFORE OCTOBER 1ST. 22. ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK STABILIZATION AND EROSION CONTROL. ROCKERIES SHALL NOT BE CONSTRUCTED TO SERVE AS RETAINING WALLS. ALL ROCKERIES IN CITY ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH CITY STANDARDS. ROCKERIES OUTSIDE OF ROAD RIGHTS -OF -WAY SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 268.00 ,o.�% PUBLIC WORKS EROSION AND SEDIMENT CONTROL PPR °: VR� DEPARTMENT GAZ 9/28/2018 1 STANDARD PLAN NOTES Pubk Works Adm .,t,a , DATE :45 A� DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 SANDBAG (TYP.) 10' MAX.. III�IIIIIII_,I _iii=1 - TOE IN SHEETING IN 4" x 4" MIN. TRENCH PROVIDE ENERGY DISSIPATION AT TOE IF EROSION IS LIKELY - 10' MAX. NOTES: 1. CONDITIONS OF USE 1.1. PLASTIC COVERING MAY BE USED ON DISTURBED AREAS THAT REQUIRE COVER MEASURES FOR LESS THAN 30 DAYS. 1.2. PLASTIC IS PARTICULARLY USEFUL FOR PROTECTING CUT AND FILL SLOPES AND STOCKPILES. 1.3. CLEAR PLASTIC SHEETING MAY BE USED OVER NEWLY -SEEDED AREAS TO CREATE A GREENHOUSE EFFECT AND ENCOURAGE GRASS GROWTH. CLEAR PLASTIC SHOULD NOT BE USED FOR THIS PURPOSE DURING THE SUMMER MONTHS. 1.4. THIS METHOD SHALL NOT BE USED UPSLOPE OF AREAS THAT MIGHT BE ADVERSELY IMPACTED BY RUNOFF. SUCH AREAS INCLUDE STEEP AND UNSTABLE SLOPES. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. PLASTIC SHEETING SHOULD HAVE A MINIMUM THICKNESS OF 0.06 MILLIMETERS. 2.2. IF EROSION AT THE TOE OF A SLOPE IS LIKELY, A GRAVEL BERM, RIPRAP, OR OTHER SUITABLE PROTECTION SHALL BE INSTALLED AT THE TOE OF THE SLOPE IN ORDER TO REDUCE THE VELOCITY OF RUNOFF. 2.3. TIRES SAND BAGS OR EQUIVALENT MAY BE USED TO WEIGHT PLASTIC. 2.4. SEAMS BETWEEN SHEETS MUST OVERLAP A MINIMUM OF 12 INCHES AND BE WEIGHTED OR TAPED. 3. MAINTENANCE STANDARDS 3.1. TORN SHEETS MUST BE REPLACED AND OPEN SEAMS REPAIRED. 3.2. IF THE PLASTIC BEGINS TO DETERIORATE DUE TO ULTRAVIOLET RADIATION, IT MUST BE COMPLETELY REMOVED AND REPLACED. 3.3. WHEN THE PLASTIC IS NO LONGER NEEDED, IT SHALL BE COMPLETELY REMOVED. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 213.30 �,®• PUBLIC WORKS PRO '�RI DEPARTMENT PLASTIC COVERING GAZ 9/28/2018 1 kwWo Ad.i-t m, DATE :45 AM DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 2"x2" 14 GAUGE WIRE, OR EQUIVALENT, IF STANDARD STRENGTH FABRIC USED FILTER FABRIC 6' MAX. -� I POST SPACING MAY BE INCREASED 4"x4" MIN. TRENCH TO 8' IF WIRE BACKING IS USED I I BACKFILL TRENCH WITH NATIVE SOIL OR 3/4" TO 1-1/2" WASHED GRAVEL 2"x4" WOOD POSTS, STEEL FENCE POSTS, OR EQUIVALENT (TYP.) NOTES: 1. CONDITIONS OF USE 1.1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS. 1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS IT INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MUST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND. 2. DESIGN AND INSTALLATION SPECIFICATIONS 2.1. THE GEOTEXTILE USED MUST MEET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MUST BE AVAILABLE ON SITE. AOS (ASTM D4751) 30-100 SIEVE SIZE (0.60-0.15mm) FOR SILT FILM 50-100 SIEVE SIZE (0.30-0.15mm) FOR OTHER FABRICS WATER PERMITTIVITY (ASTM D4491) 0.02 SECT MINIMUM GRAB TENSILE STRENGTH (ASTM D4632) 180 LBS. MIN. FOR EXTRA STRENGTH FABRIC 100 LBS. MIN. FOR STANDARD STRENGTH FABRIC GRAB TENSILE ELONGATION (ASTM D4632) 30% MAX. (WOVEN) ULTRAVIOLET RESISTANCE (ASTM D4355) 70% MIN. 2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE. 2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2HA V 2.4. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4"X4" TRENCH MAY BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE FABRIC IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE. 2.5. FILTER FABRIC FENCES SHALL BE INSTALLED ALONG CONTOURS WHENEVER POSSIBLE. 3. MAINTENANCE STANDARDS 3.1. ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY. 3.2. IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND. 3.3. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVE THE TRAPPED SEDIMENT. 3.4. SEDIMENT MUST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH. 3.5. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED. UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS) A01STD. PLAN - 214.00 �o®• PUBLIC WORKS SILT FENCE [PROM: 9/28/2018 1 '�RI DEPARTMENT GAZ Public Wo ,Admen-l- DATE :45 An DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 5" MAX. DRAINAGE GRATE TRIM GRATE FRAME _ C- OVERFLOW BYPASS d BELOW INLET GRATE DEVICE SEDIMENT AND DEBRIS b FILTERED WATER SECTION VIEW DRAINAGE GRATE (RECTANGULAR GRATE SHOWN) RETRIEVAL SYSTEM (TYP.) Q OVERFLOW BYPASS (TYP.) BELOW INLET GRATE DEVICE ISOMETRIC VIEW NOTES: 1. PROTECTION SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA, UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. 2. INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM. 3. THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE. 4. SIZE THE BELOW INLET GRATE DEVICE BIGD FOR THE STORMWATER STRUCTURE IT WILL SERVICE. 5. THE BIGD SHALL HAVE A BUILT-IN HIGH -FLOW RELIEF SYSTEM (OVERFLOW BYPASS). 6. THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE BIGD WITHOUT SPILLING THE COLLECTED MATERIAL. 7. PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION 8-01.3(15). S. ANY SEDIMENT IN THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE-THIRD OF THE AVAILABLE STORAGE. THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD" PLAN - 216"30 �O®• PUBLIC WORKS APPROVED: '�RI DEPARTMENT CATCH BASIN INSERT GAZ 9/28/2018 1 Pobkc Wo Admm­DATE :45 AP PROJECT NO. 18242 e IDEKOWA�� • • �c1�.9 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE Ate••• p 41846 a /STE• '� PLANNING o�FSS ONAL �zw��NG\��� coff DESIGN SURVEYING 10-/`) 7 2100 NE 7 95th St, Suite 300 Bothell, Washington 9807 1 425.885.7877 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING -w yqi 11 /07/2023 1 PEDESTRIAN PATH THROUGH PARKING LOT SES 11/9/22 SHM R-426405 2 CITY COMMENTS SES 6 23 23 SHM SURVEYED: ROW SCALE: HORIZONTAL NAD 1983/1991 VERTICAL, NAVE) 1988' DATUM CITY 0 F � RENTON Planning/Building/Public Works Dept. TESC NOTES AND DETAILS DATE: ✓AN. 2022 3 CITY COMMENTS SES 10 1923 SHM DESIGNED: CHI, J/c/,Y/ FIELDBOOK: PAGE: DRAWN: SES ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY DRAWING NO: s� C2. cl1 CHECKED: SHM N 0 . REVISION BY DATE APPR APPROVED: HI / SHEET: 5 OF, 10 9 Cie LL! W 0 r- I I� I I I I I I I I I I I I o � o I I � I I I I I I I � i I I I I I I I � I I I I I I �I I i I � I I I I I I I i I I I I I I I I I I I I I I I I I I I I I I 6 NO. CITY COMMENTS I SES j0/23/231 SHM I S"' D` RDW (ITV LUMMtN I (zt5 I I U/ I aLJI SFiMI DESIGNED: SHM REVISION DRAWN: SES CHECKED: SHM BY I DATE I APPR I APPROVED: SHM ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERnCAL• NAVE) 1988 HORIZONTAL- NAD 1983/1991 DATUM ATNN EI a N M O O PM--,� O 1 O� SCALE: 1" = 10' 0 5 10 20 J- HYA CLASS 1/2" Ln 4" M/N. J14" - 1-112" MINUS CRUSHED ROCK M (WSDOT ,9 .. 9(3)) COMPACTED TO 959 OF MAX DRY DENSITY (AST 01557) O NA TI VE SOIL PA VEMENT SECT/ON N NO SCALE SO N M O O M M PROJECT NO. 98242 U y�IDEKO .Of WAS yy9 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE • PLANNING o •� 41846 �o�Fs TONAL DESIGN SURVEYING 10-1�-Z3 7 2100 NE 7 95th St, Suite 300 Bothell, Washington 9807 1 425.885.7877 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING c ss - yqi 11 /07/2023 ' 1 1d f 0 CITY OF RENTON Planning/Building/Public Works Dept. ROAD AND GRADING PLAN DATE: ✓AN. 2022 FIELDBOOK: PAGE: DRAWING NO: C3.01 SHEET: 6 OF: 10 ROO `1 O O O O M1 � J N s N M O O M N V FACE OF CURB -612_ 5 112" 1" 1/2" R. 1"R. 1:24 1 1 TOP OF is 1/2" R. ROADWAY I_ t r fDi 1'-6" _ CEMENT CONCRETE TRAFFIC CURB AND GUTTER FACE OF ADJACENT CURB 612"_ FLUSH WITH GUTTER PAN AT SIDEWALK RAMP ENTRANCE 1:12 1:24 TOP OF 1/2" R. ROADWAY 1 i� I DEPRESSED CURB SECTION AT SIDEWALK RAMPS II FAi PREMOLDED JOINT FILLER E FULL -DEPTH EXPANSION JOINT _ 6" CEMENT CONCRETE 1/2" R. 1"R. SIDEWALK RAMP VARIES OR LANDING FROM [ 6" TOO --- 6" r 3/B" PREMOLDED JOINT FILLER CEMENT CONCRETE PEDESTRIAN CURB AT SIDEWALK RAMPS AND LANDINGS FACE OF ADJACENT CURB 612"_ SEE DEPRESSED CURB DETAIL THIS SHEET 1:24 TOP OF r , ' 1• 1/2"R. ROADWAY z" - - , I 1 V-6' DEPRESSED CURB SECTION AT RESIDENTIAL DRIVEWAYS ONLY. FOR COMMERCIAL DRIVEWAYS SEE STD PLAN 104.2 FACE OF CURB _ 6 12-_ - - s 12" 1" 1/2' R. _ _ 1" R. CENTCURB 1 1 • � TOP OF ROADWAY ER SURFACE { I 6 1 A" DEPRESSED B DETAIL AT RESIDENTIAL OR COMMERCIAL DRIVEWAYS, AND ALLEYS GENERAL NOTES: 1. See standard plans 102 and 101.1 for curb expansion and contraction joint spacing. 2. Expansion joint shall be full depth, 3/3" (in.) premolded joint Tiller. 3. For Depressed Monolithic Driveway Curb 8 Gutter Section, see Standard Plan 104.2 STD. PLAN - 101 • PUBLIC WORKS DEPARTMENT CEMENT CONCRETE CURBS IPPP `, ED 3/8- PRFWOLDED JOINT FILLER (TYP) FACEOF CENTERLINIEOF CURB I_� FRAME 6GRATE 6 1/2' 13' I(` _8EENOTE2 /8"R X 5/B"D DUMMY JOINT BEENGTE2 _G• 2' 0' b pp - I I ' � I CEMENTCONCRtTE CURS AND GUTTER PLAN VIEW 5 1 2 - 1 MATCH FRAmEANoGPATE-NOT INCLUoED 1/2" R. 1' R. RWIDWAYLINRBAND GUTTER BID ITEM RO"SLOPE TOP OFI' R• �ROADWAY p p �. b p G 9 .'! - o - • ADJUSTMENT SECTION -NOT INCLUDED . e• p' IN CURB AND GUTTER BID ITEM CATCH SABtN - NOT WOLUDED p • ! ' IN CURS AND GtJTIER SD ITEM p ,P SECTION O /-• GENERAL NOTES: 1. The Intent of this design Is to facilitate the removal ; of a catch basin with minimal disturbance of the curb. - 2- The expansion joints of the "!?Ell "� '~ adjacent sidewalk shall i i :� : • be adjusted to be In - line with these curb expansion joints. ISO�AF_41C VIEW SM. PLAN - IMA CEMENT CONCRETE CURB PUBLIC WORKS INSTALLATION AT PRO D: DEPARTMENT CATCH BASINS DAM T - 0" 6"1 SIDEWALK (SEE CONTRACT) FOR SIDE TREATMENT SIDEWALK 6 1/2" 1' - 0" 1' - 0" SEE OTHER SIDEWALK SECTIONS (SEE CONTRACT) ROUNDING 2'0% 1/2" (IN) R. (TYP.) I Ill 1 1/2" (IN) R. (TYP.) CURB NOT INCLUDED IN BID ITEM - 1 2.0% MAX. v 2.0% MAX, SEE STANDARD PLAN F-10.12 - CAP SEE RAISED EDGE 3/8" (IN) PREMOLDED SEE CURB FACE DETAIL DETAIL - THIS SHEET JOINT FILLER WITH RAISED EDGE MONOLITHIC CEMENT CONCRETE O1 FINISHED GRADE 1" (IN) BELOW TOP OF CONCRETE SURFACE CURB AND SIDEWALK 2'-0" SIDEWALK NOTE 1' - 0" 1' - 0" MIN. (SEE CONTRACT) 1/2" (IN) R. (TYP.) 1. Gratings, Access Covers, Junction Boxes, Cable Vaults, Pull Boxes and other ROUNDING CURB NOT INCLUDED IN BID ITEM - appurtenances within the Sidewalk must have Slip resistant Surfaces, be flush _2.0% 1 2.0% MAX SEE STANDARD PLAN F-10.12 with surface, and match grade of the sidewalk. ^� gC��pc� PREMOLDED) WALL OR BARRIER -, ,�,�P� JOINT FILLER ADJACENT TO CURB (STEEP FILL SLOPES) SIDEWALK 1'-0" SIDEWALK 1/2"(IN)R. 0 LL ALL CUT MIN. (SEE CONTRACT) 24,,0" > SLOPES D 0 1/2" (IN) R. (TYP.) b" D D G 20% 1 CURB NOT INCLUDED IN BID ITEM - - - 2.0% MAX. SEE STANDARD PLAN F-10.12 3/8" (IN) PREMOLDED JOINT FILLER Z AN CtER G Q 0 3/8" (IN) PREMOLDED JOINT FILLER f SIDEWALK ADJACENT TO WALL DETAIL G ADJACENT TO CURB BRIDGE OR PEDESTRIAN RAILING SEE © 61/2I CONTRACTION FACE OF CURB JOINT 51/2" 1" v " D D 1 iD ROADWAY ' D N D 8" 6 1/2" I 1" CURB FACE DETAIL EXTEND SIDEWALK TRANSVERSE EXPANSION JOINTS TO INCLUDE CURB (FULL DEPTH) BROOMED FINISH (TYP.) 4" (IN) WIDE. SMOOTH -TROWELED PERIMETER CEMENT CONCRETE CURB (CURB AND GUTTER SHOWN) NOT INCLUDED IN BID ITEM SEE STANDARD PLAN F-10.12 CONTRACTION JOINT BARRIER -SEE SIDEWALK c IN SIDEWALK ONLY CONTRACT PLANS \y/ I (SEE CONTRACT) I i I 1/2" (IN) R. (TYP.) / I I FLUSH I 20% MAX r VERTICAL WALL •- 3/8" (IN) PREMOLDED SEE DETAIL JOINT FILLER (TYP.) ADJACENT TO CURB AND RAILING OR WALL 3' - 0" MIN. FOR SIDE TREATMENT SIDEWALK BUFFER STRIP SEE OTHER SIDEWALK (SEE CONTRACT) (SEE CONTRACT) SECTIONS LEVEL 'ram CURB NOT INCLUDED IN BID ITEM - (IN) R. SEE STANDARD PLAN F-10.12 tt D 1" )R.- RAISED EDGE DETAIL EXTEND SIDEWALK TRANSVERSE JOINTS TO INCLUDE RAISED EDGE 1 1/2" (IN) R. CURB NOT INCLUDED IN BID ITEM - 2.0% MAX (TYP,) SEE STANDARD PLAN F-10.12 FINISHED GRADE 1" (IN) BELOW TOP OF CONCRETE SURFACE FOR PLANTING - FLUSH IF PAVED ADJACENT TO BUFFER STRIP PREMOLDEI JOINT FILLER E) EXPANSION JOINT 1 3 M �- SD EXPANSION JOINT IN BOTH �L S. F CURB AND SIDEWALK `1 WAS/// G` l3v ISOMETRIC VIEW JOINT AND FINISH sv DETAIL oA� �CI STBR�� `�sv ss10NAL t Michael S Digi ally signed by Michael Fleming Fleming Date: 2020.09.24 07:40:16-07'00' 1/� CEMENT CONCRETE SIDEWALK ���• ° . STANDARD PLAN F-30.10-04 D o SHEET 1 OF 1 SHEET p APPROVED FOR PUBLICATION Date: 2020.09.25 15:43:50-07'00' STATE DESIGN ENGINEER Amok © CONTRACTION JOINT ffir Washington State Department of Transportation PEDESTRIAN PATH THROUGH PARKING LOT SES 11/9/22 SHM CITY COMMENTS SES 6/23/23 SHM SURVEYED: RDW CITY COMMENTS SES 10 1923 SHM DESIGNED: SHM DRAWN: SES CHECKED: SHM REVISION BY DATE APPR APPROVED: SHM DO I � IDEMSHAiZ REPLACED TO THE N�ARffT, ✓,ollyT i II 160.67 15 SAWCUT EXIST/NG �- 20 PA VEMENT VAN ADA STALL - I o 160.67 16 AD I - - - - SD REMOVE EXISTING ACCESSIBLE 4 A P I L T RAMP 1 SPACE 18' (T� -� 16 4.5' 160.77 S EXP ND EXIS G PARKING 4 a LOT PER PA VEMENT a -I�ITIFO FAQUOUNIT DEVI Kir, Z1, S CPON ON THIS SHEET - - Ji 160.78 �O 159.82 - --�� I II 159.9 �- kP M2. 74 a 161.2 1 r 162.74 160.E I15� 07 J. 1.59 � � ° 7�i ° �61.4f 162. 59' 160.6 - Q Of6237, 16.21' RT a ELEV 161.341 a 1 162.74 (FG, TC) GRADING DETAIL 1 /S -'4 5' 161.96 _ e 29 I „1.09 GRA E � O BRE K- - ❑ BARD RA/N (CONNECTED TO SEWER) a fa RIM 161, 88 211, - SD �-SD - - - - - - -� S S - SS SD SD SDf - - - - - - - - - - - -� - - - - - - - - - - -I- 8' 0.5' .WALK_ I _ 18' PLANTER -.1 46' PARK/NG LOT SECTION A A SCALE- 1 " = 10' GRADING DETAIL 2 SCALE: VERTICAL HORIZONTAL- NAD 1983/1991 CITY OF RENTON ONE INCH DATUM AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY SCALE.` 1 " = 10' BUILDING 4.5' 7' PROJECT NO. 18242 t SIDEKO pF N'ASy�•'cy?, CIVIL ENGINEERING LANDSCAPE ARCHITECTURE Ate••• p 41846 a • '� PLANNING o�FSS ONAL DESIGN SURVEYING 10-1�-Z3 72100 NE 795th St, Suite 300 Bothell, Washington 9807 1 425.885.7877 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING yqi 11 /07/2023 ROAD AND GRADING DETAILS DATE: FIELDBOOK: 2022 PAGE: DRAWING NO: C3.31 SHEET: 8 OF: 10 Slo 9 S 45TH PL F 0 a O I i / ; \ CB 8073 TYPE I I RIM EL=148.80 12"CMP(S)IE-195.45 32 TYPE I I 18" CONC(N)IE-145.40 EL=148.75 it I )IE=146.50 a I CB 8072 TYPE RIM EL-]/8.60 0 4°PVC(S IE=146.59 4" V /W) I E=146.53 c� 0 oo- SS Of001 0 ° I SMH s 50LF VEGETA TED / I FLOW PATH 8146 TYPE - RIM EL=156.68 I 4' PVC(NE)IE=155.45 6°CP„ 4"CPEP(N)IE-154.71' 6 /E 160.41 / 4"cPEP(N)IE�1 L 13LF 6" PVC CsX> 02 12" CMP($.}iE=154 '7F x o °a - IM EL-150.,T 45.17 �8"PVC(W)IE 139.02 12"PVC(S)IE 138.72 12" PVC(N)l=138.62 0 3 I ,s STA. 1 *25, 28.65 L T a TYPE 1, w RIM 158.07 8" If OUT 154.97 (S) /I 00/ CSDMH 7 O = I / I 1 111, RIM EL=159.04 o ° STA. 0*97, 34.29LF 814 L T / " PVC 6 PVC(S)IE=155.19 j J i 8 CMP(W)IE=151 64 PROPOSED SPLASH BLOCK ELEV 161.58 6" PVC PIPE - STORM CONNECTION 6" If 161.75 a II TPN: 312305-9069 II T. GARDNER 4512 TALBOT RD S 98055 TYPE 2-48, ®0.0052 18"CMP(E)IE=151.64 I SDMH #8148, TYPE II a RIM 1589.3 8" If /N 151.64 (E) I I PROP 8" Io-'-RIM EL=158.93 1E 155.19 36"CMP(N)IE=151.48 II II d 6" 1E IN 155.19 (5) SD sD "CMP(W)IE=151. p a. 8" If IN 154.82 (N) o I I CB 8095 TYPE SDY 4 o ° 8" If OUT 151.27 (W) RIM EL=152.74 I Ef 0 I I / 8"CMP(E)IE=151.24 I 5 6� a I 8°CMP(W)IE=151.16 e' e4 1.• I 8 I � e bb a ryM� I 6 EXl517NG ° Q0 STORM a° a, N REPLACE SOLID LID r WITH A VANED GRATE ° I 9 I EX/STING SEWER II I-- 5TUBVER/FY CB M EL TYPE I CONNECTION I RIM EL=159.96 =162. 2 a' O 6" PVC(E)IE=156.4 6" C(E)IE=1 �$.00 SS II TO BUILD/NG 6"PVC(N)I - 6' PVC(N)IE=/158. 0 G I APPROX. LINE SIDE SEW-,. RAISE SOCO TO , FINISHED GRADE -� PER ASBUILTS I ° a OF 16 1. 09 I I o a: a 13 \ RIM EL 164.40 - 1126.26 a / -� i � \ 6"PVcNVE IE 158.38 CB 11 7 YPE .3 EL=16.4 cSSMH P ASBUILT SS SD -_ -S� - �_ o v _ P e 0 OH N 04 OHP OHP OHP / -- - 30.0o o w D ° SD - / P ----- P o ° CB 8091 TYPE I / I RIM EL=156.16 a 4"PVC(E)IE=154.79 / I 12"PVC(S)IE=154.17 12"CMP(N)IE-154.11 I I SSMH 8213 RIM EL=156.76 12°PVC(S)IE=146.21 ',a 12"PVC(N)IE=l46.06 loo � I I 29LF 6" PVC 0 MIN SLOPE 0.02 it EX/STING FOOTING DRAIN CONNECT/ON \ /F -1 6" IE 42 �12 6" VC © 0. 0 REMOVE 171E EXISTING SPLASH BLOCK CONNECT THE ROOF h AV TO THE EXISTING STORM o EXISTING SPLASH BLOCK 6" E 158.66 RIM EL=162.12 I �/4"PVC(E)IE=161.22 _ I I H 11269 RIM E -166 775 _ o S SDSD SD SS 1P oHP REPLACE EXISTING GRATE - - - - - w w WITH A SOLID LID AND PAVE CB PER ASBUILT OVER WITH CONCRETE - - - - - - - - - - - - - CONNECT AREA DRAIN FOR DUMPSTER TO THE I 10' ELECTRIC LINE EASEMENT SIDE SEWER I REC. NO. 6023496 RIM 161.87 - - 4" If 158.87 1 PEDESTRIAN PATH THROUGH PARKING LOT 2 CITY COMMENTS 3 CITY COMMENTS NO. I REVISION SES 11/9/22 SHM SES 6/23/23 SHM SURVEYED: ROW SES 10 1923 SHM DESIGNED: SHM DRAWN: SES CHECKED: SHM BY DATE APPR APPROVED. SHM I II I I I I I _ I I I I I I SCALE: ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY V SCALE: 1" = 20' 0 10 20 40 PROJECT NO. 18242 1 SIDEKO ..'pF WAS,y�y 99 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE -o ' 41846 PLANNING TONAL DESIGN SURVEYING 10-1�-11-73 7 2100 NE 7 95th St, Suite 300 Bothell, Washington 9807 1 425.885.7877 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING yqi 11 /07/2023 ' WASTEWATER UTILITY' Kl.,)"Ik R-426409 jstowell 11 /07/2023 DATE: VERTICAL• NAVD 1988 • HORIZONTAL- NAD 1983/1991 CITY OF ✓AN. 2022 FIELDBOOK: RENT 0 N UTILITY PLAN PAGE: DATUM DRAWING No: Planning/Building/Public Works Dept. C4• 01 SHEET: 9 OF: 10 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 DocuSign Envelope ID: 3B1 B34D3-7EOA-476C-ADB3-4329FFEOC1 08 I \ 2 5 \Tj S• 11', 2", 4', 6", 12'. OR 24" ONE #3 BAR HOOP FOR 6" HEIGHT INCREMENT (SPACED EQUALLY), SEE NOTE 1 RECTANGULAR ADJUSTMENT SECTION C,O,S�6 E� ti6 5 A #3 BAR EACH CORNER I /T #3 BAR EACH SIDE sFF 22„ °rFa #3 BAR EACH WAY PRECAST BASE SECTION #3 BAR HOOP #3 BAR EACH CORNER 18" MIN. SEE NOTE 1 ALTERNATIVE PRECAST BASE SECTION V0PUBLIC WORKS DEPARTMENT PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR PLAIN 12" CONCRETE ALL METAL PIPE 15" CPSSP", 12" STD. SPEC. 9-05.20 SOLID WALL PVC, STD. SPEC. 9-05.12(1) 15" PROFILE WALL PVC, STD. SPEC. 9-05.12(2) 15" ' CORRUGATED POLYETHYLENE STORM SEWER PIPE NOTES: 1. AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN IN THE PRECAST BASE SECTION, FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED. 2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 20". KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5 FEET. 4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. 5. THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1 H:24V OR STEEPER. 6. THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. 7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR NON -SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9-20.3(2). 8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES. 9. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 10. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 11. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NITS) STD. PLAN - 200.00 APPR ED: CATCH BASIN TYPE 1 GAZ 9/28/2018 1 Public Wo,k,Adm i,1,. u DATE DocuSign Envelope ID: 3B1B34D3-7EOA-476C-ADB3-4329FFEOC108 SURFACE WATER STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE SURFACE WATER STANDARD PLAN NOTES. 1 BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY, THE APPLICANT, AND THE APPLICANTS CONTRACTOR. 2. THE APPLICANT SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY CITY, STATE, AND FEDERAL PERMITS PRIOR TO CONSTRUCTION. 3. ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM), RENTON MUNICIPAL CODE (RMC), AND THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA). IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT TO CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THE PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO THE CITY. 4. APPROVAL OF THE ROAD, GRADING, PARKING, BUILDING, AND DRAINAGE PLAN DOES NOT CONSTITUTE AS APPROVAL OF ANY OTHER CONSTRUCTION (E.G. WATER, SEWER, GAS, ELECTRICAL. ETC.). PLANS FOR STRUCTURES SUCH AS BRIDGES, VAULTS, AND RETAINING WALLS REQUIRE A SEPARATE REVIEW AND APPROVAL BY THE CITY PRIOR TO CONSTRUCTION. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE COORDINATION FOLLOWED BY WRITTEN APPROVAL FROM THE CITY. 5. A COPY OF THE APPROVED PLANS SHALL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 6. THE LOCATIONS OF ALL EXISTING UTILITIES SHOWN HEREON HAVE BEEN ESTABLISHED BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHALL THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE APPLICANTS CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN, AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HEREON THAT MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. THE APPLICANT SHALL RECORD ON THE AS -BUILT DRAWINGS ALL UNDOCUMENTED UTILITIES DISCOVERED AND ANY CHANGES TO THE APPROVED PLANS. THE APPLICANT SHALL IMMEDIATELY NOTIFY THE ENGINEER OF RECORD IF A CONFLICT EXISTS. 7. VERTICAL DATUM SHALL BE NAVD 88 AND HORIZONTAL DATUM SHALL BE NAD 83 (WA STATE PLANE, NORTH), UNLESS OTHERWISE APPROVED BY THE CITY. REFERENCE BENCHMARK, DATUM, AND ELEVATIONS SHALL BE NOTED ON THE PLANS. 8. ALL UTILITY TRENCH BACKFILL AND ROADWAY SUBGRADE SHALL BE COMPACTED TO 95% MAXIMUM DRY DENSITY PER SECTION 2-03.3(14)D - COMPACTION AND MOISTURE CONTROL TESTS OF THE WSDOT STANDARD SPECIFICATIONS. IN PERMEABLE PAVEMENT AND OTHER INFILTRATION AREAS, ALL TRENCH BACKFILL SHALL BE FIRM AND UNYIELDING BUT IN NO CASE SHALL BE COMPACTED TO MORE THAN 92% OF MAXIMUM DRY DENSITY. D OPEN CUTTING OF EXISTING ROADWAYS FOR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY AND NOTED ON THESE APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATION STANDARDS. 10. ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TO THE START OF CONSTRUCTION. WHERE SHOWN ON THE PLANS OR WHERE DIRECTED BY THE CITY, THE EXISTING MANHOLES, CATCH BASINS, OR INLETS SHALL BE ADJUSTED TO THE GRADE AS STAKED. 11. ALL FLOW CONTROL FACILITIES SHALL BE INSTALLED AND IN OPERATION PRIOR TO, OR IN CONJUNCTION WITH, ANY CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE CITY. 12. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE, ALL PIPE BEDDING AND BACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLAN 220.00, 220.10, AND 220.20. 13. STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT 1, 2, OR 5 INSIDE AND OUTSIDE. 14. ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL BE FITTED WITH DUCTILE IRON, BOLT -LOCKING LIDS PER THE CITY STANDARD PLAN 204.10, 204.20, 204.30, 204.40, AND 204.50. STRUCTURES SHALL HAVE: • RECTANGULAR OR ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND OUTSIDE OF THE ROADWAY. • ROUND, SOLID LIDS WHEN NOT COLLECTING RUNOFF, AND LOCATED WITHIN THE ROADWAY, BUT OUTSIDE OF THE CURB/GUTTER LINE. • ROUND, SOLID LIDS DISPLAYING THE CITY LOGO WHEN WITHIN THE PUBLIC RIGHT-OF-WAY OR IN AN EASEMENT TO THE CITY. PRIVATE STRUCTURE LIDS OUTSIDE PUBLIC RIGHT-OF-WAY AND EASEMENTS TO THE CITY SHALL NOT DISPLAY THE CITY LOGO. 15. BUILDINGS AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH TABLE 4.1 EASEMENT WIDTHS AND BUILDING SETBACKS LINES OF THE RENTON SWDM. 16. LIDS OF MANHOLES/CATCH BASINS WITHIN PUBLIC RIGHT-OF-WAY SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL AFTER PAVING. ALL MANHOLE/CATCH BASIN RIMS SHALL BE ADJUSTED TO BE FLUSH WITH FINAL FINISHED GRADES, UNLESS OTHERWISE SHOWN. 17, ALL DRIVEWAY CULVERTS LOCATED WITHIN CITY RIGHT-OF-WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) AdiSTD. PLAN - 267.00 ,•®• PUBLIC WORKS SURFACE WATER STANDARD PLAN E6I;WPdby: Fill DEPARTMENT NOTES (1 OF 2) artin Pastucha8/13/2020 DATE �&1�3ESD888#A®D... :45 Al 18:4E SEE NOTE 4 CLEAN SURFACE AND BOTTOM AREA. / PROVIDE UNIFORM CONTACT. THE SURFACE AREA OF THE BASE SECTION MUST BE MORTARED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION ADJUSTMENT SECTION BASE SECTION NOTES: 1. THE COVER OR GRATING OF A CATCH BASIN SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL THE FINAL ELEVATION OF THE PAVEMENT, GUTTER, DITCH, OR SIDEWALK IN WHICH IT IS TO BE PLACED HAS BEEN ESTABLISHED, AND UNTIL PERMISSION THEREAFTER IS GIVEN BY THE ENGINEER TO MORTAR IN PLACE IN ACCORDANCE WITH WSDOT/APWA STANDARD SPECIFICATION 7-05.3. 2. SHIMS SHALL NOT BE USED TO SET FRAME TO GRADE. THE USE OF SHIMS IS PROHIBITED. 3. A CONTINUOUS LAYER OF MORTAR SHALL BE PLACED BETWEEN ADJUSTMENT RINGS AND BRICKS PRIOR TO PLACEMENT. 4. ONLY BY APPROVAL OF THE CITY, THE USE OF BRICKS IS PERMITTED WHERE THE BRICKS ARE STAGGERED TO CREATE A RUNNING BOND ORY2 BOND. 5. BASE SECTION SHALL BE SEALED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION WITH MORTAR. 6. MORTAR SHALL MEET THE REQUIREMENTS OF WSDOT/APWA STANDARD SPECIFICATION 9-04.3. 7. PICK / LIFTING HOLES ARE TO BE GROUTED WATER TIGHT. USE GROUT TYPE 2 FOR NON -SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9-20.3(2). 8. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 9. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 10. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) A109STD. PLAN - 202.00 �•®• PUBLIC WORKS PRO, '��� DEPARTMENT CATCH BASIN INSTALLATION GAZ 9/28/2018 I 9 r DATE �mm won: aammi:n,ro, DocuSign Envelope ID: 3B1B34D3-7EOA-476C-ADB3-4329FFEOC108 SURFACE WATER STANDARD PLAN NOTES: THE FOLLOWING IS A LISTING OF GENERAL NOTES THAT SHALL BE INCORPORATED IN THE DRAINAGE PLAN SET. ALL THE NOTES ON THE LIST MAY NOT PERTAIN TO EVERY PROJECT. THE APPLICANT OR OWNER, HEREBY REFERRED TO AS APPLICANT, MAY STRIKE OUT IRRELEVANT NOTES IF NOT APPLICABLE TO THE PROJECT. HOWEVER, THE APPLICANT SHALL NOT RENUMBER NOR EDIT THE REMAINING NOTES. IF ADDITIONAL NOTES ARE NEEDED FOR SPECIFIC ASPECTS, THEY SHALL BE ADDED AFTER THE SURFACE WATER STANDARD PLAN NOTES. 18. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A MINIMUM DEPTH OF ONE (1) FOOT AND SHALL MEET THE FOLLOWING SPECIFICATIONS: • 4-8INCH ROCK /40-70%PASSING; • 2-4INCH ROCK I30-40%PASSING; AND • LESS THAN 2 INCH ROCK / 10 - 20% PASSING. 19. FOOTING DRAINAGE SYSTEMS AND ROOF DOWNSPOUT SYSTEMS SHALL NOT BE INTERCONNECTED AND SHALL SEPARATELY CONVEY COLLECTED FLOWS TO THE CONVEYANCE SYSTEM OR FLOW CONTROL FACILITY ON THE SITE, UNLESS APPROVED BY THE CITY. FOOTING DRAINS SHALL NOT BE CONNECTED TO ON -SITE BMPS. 20. THE END OF EACH STORM DRAIN STUB SHALL BE CAPPED. A CLEANOUT TOPPED WITH A BOLT -LOCKING LID MARKED "STORM" OR "DRAIN" SHALL BE LOCATED AT THE PROPERTY LINE OR AT THE POINT OF CONNECTION OF A PRIVATE STORM DRAINAGE CONVEYANCE SYSTEM PER THE CITY STANDARD PLAN 227.00. 21. ALL STORM SYSTEM EXTENSIONS SHALL BE STAKED FOR LINE AND GRADE BY A SURVEYOR LICENSED IN WASHINGTON STATE AND CUT SHEETS SHALL BE PROVIDED TO THE CITY PRIOR TO CONSTRUCTION. 22. ALL NEWLY -INSTALLED AND NEWLY -REHABILITATED (PUBLIC AND PRIVATE) STORM CONVEYANCE SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE CCTV ACCORDING TO THE CITY STANDARD PLAN 266.00. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY PRIOR TO RECEIVING APPROVAL TO INSTALL PROJECT CURBS, GUTTERS AND/OR PAVEMENT. 23. ALL STORM SYSTEMS AND CONNECTIONS TO EXISTING MAINS SHALL BE TESTED IN ACCORDANCE WITH SECTION 7-04.3(1) OF THE WSDOT STANDARD SPECIFICATIONS AND IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY. STORM DRAIN STUBS SHALL BE TESTED FOR ACCEPTANCE AT THE SAME TIME THE MAIN STORM IS TESTED. 24. FOR ALL DISTURBED PERVIOUS AREAS (COMPACTED, GRADED, LANDSCAPED, ETC.) OF THE DEVELOPMENT SITE, TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL EITHER STOCKPILE AND REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR AMEND THE SOIL WITH COMPOST IN ACCORDANCE WITH STANDARD PLAN 264.00. 25. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY DOES NOT RELIEVE THE APPLICANT OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED WITH STORMWATER DISPOSAL. THE CITY DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE STORM SYSTEM PROVIDED DURING CONSTRUCTION. 26. ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER ACTIONS NEEDED TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK SHALL BE PROVIDED. ANY WORK WITHIN THE TRAVELED RIGHT-OF-WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVED BY THE CITY. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-10 TEMPORARY TRAFFIC CONTROL SHALL APPLY. 27. PROJECTS LOCATED WITHIN THE CITY'S AQUIFER PROTECTION AREA (APA) SHALL COMPLY WITH SPECIAL REQUIREMENT #6 OF THE RENTON SWDM AND AQUIFER PROTECTION REGULATIONS (RMC 4-3-050). 28. PLACEMENT OF SURFACE APPURTENANCES (CATCH BASIN/MANHOLE LIDS, CLEANOUTS, INLETS, ETC.) IN THE STREET TRAVEL LANE WHEEL PATH, INTERSECTIONS OF STREET TRAVEL LANES, BIKE LANES, SIDEWALKS, AND CROSSWALKS SHALL BE AVOIDED WHENEVER POSSIBLE. ANY SURFACE APPURTENANCE PLACED IN A SIDEWALK OR CROSSWALK SHALL BE FITTED WITH A NON -SLIP OR NON-SKID LID PER ADA REQUIREMENTS. 29. CLEARLY LABEL PUBLIC AND PRIVATE SYSTEMS ON THE PLANS. PRIVATE SYSTEMS SHALL BE MAINTAINED BY THE APPLICANT. 30. MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4.2.1.A2 OF THE RENTON SWDM. 31. CONSTRUCTED PERMEABLE PAVEMENT SHALL BE PERMEABLE ENOUGH TO ABSORB WATER AT A MINIMUM RATE OF 20 INCHES PER HOUR IMMEDIATELY AFTER THE PAVEMENT SURFACE HAS BEEN WETTED CONTINUOUSLY FOR AT LEAST 10 MINUTES. COMPLIANCE WITH THIS MINIMUM RATE SHALL BE CHECKED PRIOR TO CONSTRUCTION APPROVAL OF THE PAVEMENT. COMPLIANCE MAY BE CHECKED USING A SIMPLE BUCKET TEST IN WHICH 5 GALLONS OF WATER IS POURED ONTO THE PAVEMENT SURFACE ALL AT ONCE. IF ONLY A MINOR AMOUNT OF WATER PONDS OR RUNS OFF THE SURFACE THEN THE PAVEMENT IS CONSIDERED TO MEET THE MINIMUM RATE OF ABSORPTION. AT LEAST ONE TEST SHALL BE CONDUCTED PER 1,000 SQUARE FEET OF PERMEABLE PAVEMENT. IF THIS TEST IS NOT CONCLUSIVE, THEN ANOTHER TEST PER ASTM C1701 SHALL BE CONDUCTED. FOR LARGE AREAS (E.G., PARKING AREAS), TESTING OBSERVATION MAY BE ACCOMPLISHED WHILE WALKING BEHIND A SLOWLY MOVING WATER TRUCK DISCHARGING WATER AT A RATE SIMILAR TO THE BUCKET TEST. PERMEABLE PAVERS SHALL BE TESTED USING ASTM C1781. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 267.10 PUBLIC WORKS SURFACE WATER STANDARD PLANE-bikd by: i DEPARTMENT NOTES (2 OF 2) artin PastuchA11312020 a-, 1a: DATE BB8QikF098BA"D... :45 Ai 8:48 �•�, 3/4" FLAT FACE GOTHIC L� 9„ DIA 5/ ' y❑❑ ❑ ❑ STORM ❑ 4" ❑ ❑ ❑ ❑ q T 8-13/16" DIA ❑❑ 1 8-1/8" DIA 10-1/2" DIA (2) 3/8"-16 SS SOCKET HEAD CAP 15" DIA (1) OPEN PICKHOLE 1" SCREW (ALLENHEAD) W/WSHRS 5�8. ON A 8" DIA BOLT CIRCLE CAST IRON FRAME AND COVER, SEE NO^TE3 I- I I " 11 1 8" CLASS "B" ASPHALT. SEE NOTE 4 CLEANOUT RISER, SEE NOTE 2 SOIL TIGHT 45' BEND WYE SOIL TIGHT COUPLER UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR ` ROOF DRAIN COLLECTOR . / PIPE, SEE NOTE 1 (1 111111m TO OVERFLOW STRUCTURE OR STORM MAIN PAVED AREA (TYP.) 12" EXTEND CLEANOUT RISER 2" ABOVE DESIGN PONDING ELEVATION OR PER PLAN - V a DESIGN PONDING ELEVATION - 4" COMPACTED SAND OR GRAVEL BACKFILL FOR DRAINS PER WSDOT M3.12(4) Q CLEANOUT RISER, � 1I SEE NOTE 2 III FERNCO GASKETED QUIK CAP OR SIMILAR 4"STREAMBED COBBLES PER WSDOT 9-03.11(2) CLEANOUT RISER LOCATED WITHIN BIORETENTION PONDING AREA MECHANICAL PLUG OR CONTINUED CONNECTION TYPICAL CLEANOUT CONFIGURATION NOTES: 1. DIAMETER TO BE 6-INCHES MINIMUM PRIVATE, 8-INCHES MINIMUM PUBLIC. UNDERDRAIN PIPE PER STD. PLAN 262.10. 2. CLEANOUT RISER SHALL BE SAME MATERIAL AS CONNECTED UNDERDRAIN FOOTING DRAIN COLLECTOR OR ROOF DRAIN COLLECTOR PIPE. 3. FRAME AND COVER SHALL BE EJ PRODUCTS 3675Z1 PT AND 3675APT OR APPROVED EQUAL. COVER TO BE LOCKING WITH ALLEN HEAD BOLT, MARKED "STORM" OR "DRAIN". 4. FOR CLEANOUTS FULLY OR PARTIALLY WITHIN UNPAVED AREAS OUTSIDE OF BIORETENTION PONDING AREA, POUR 8" THICK, 2'x2' SQUARE CONCRETE COLLAR AROUND FRAME. CONCRETE COLLAR SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI. GENERAL NOTES: 1. CLEANOUTS FOR UNDERDRAIN, FOOTING DRAIN COLLECTOR, AND ROOF DRAIN COLLECTOR PIPES SHALL BE INSTALLED AT A MINIMUM OF EVERY 100 FEET, AT EVERY 90 DEGREE OR SECOND 45 DEGREE BEND, AT THE END OF EVERY COLLECTOR PIPE, AND AT EACH END OF AN UNDERDRAIN PIPE NOT CONNECTED TO AN OVERFLOW STRUCTURE. CLEANOUTS SHALL BE INSTALLED TO ALLOW FOR MAINTENANCE ACCESS TO ALL PIPES. 2. ALL FITTINGS SHALL BE SOIL TIGHT. 3. CLEANOUT RISER SHALL BE LOCATED OUTSIDE OF BIORETENTION PONDING WHERE POSSIBLE. 4. CLEANOUTS SHALL NOT BE LOCATED WITHIN THE STREET TRAVEL LANE, UNLESS OTHERWISE APPROVED BY THE CITY, UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE (NTS) STD. PLAN - 226.00 ,• PUBLIC WORKS B6084pledby: DEPARTMENT STORM SYSTEM CLEANOUT artin Pastucha 8/13/20 v4m%7 11 '�=OMWWD... DATE 1 PEDESTRIAN PATH THROUGH PARKING LOT SES 11/9/22 SHM 2 CITY COMMENTS SES 6/23/23 SHM SURVEYED: RDW SCALE: 3 CITY COMMENTS SES 10 1923 SHM DESIGNED: SHM DRAWN: SES C ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY CHECKED: SHM N 0 . REVISION BY I DATE APPR APPROVED: HI / 1 8: PROJECT NO. 18242 t �IDEK0 •W. A' CIVIL ENGINEERING �Y7I I Z. LANDSCAPE ARCHITECTURE Ate••• p 41846 a • '� PLANNING o�FSS ONAL DESIGN SURVEYING 10- /`) 7 2100 NE 7 95th St, Suite 300 Bothell, Washington 9807 1 425.885.7877 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING % yqi 11 /07/2023 R-426410 DATE: VERTICAL, NAVD 1988 HORIZONTALNAD 1983/1991 • CITY 0 F ✓AN. 2022 'IL FIELDBOOK: ,4jRENT 0 N UTILITY DETAILS PAGE: DATUM DRAWING No: Planning/Building/Public Works Dept. C4. cl1 SHEET: 10 OF: 10 i i 0106 Al I �I O 1 O7PROPFRT`Y LINE ADJUST EXISTING PLANTS AS NEED \ IN FLOW PATH (SEE CIVIL) �,ti--t--ADJACENT PROPERTY: COMMERCIAL ZONING EXISTING HEDGE TO REMAIN, "--� LIMITS OF DISTURBANCE, SS S SS __SS_ % EXISTING TREES — — — — -'— REPLACE SHRUBS DISTURBED _ — — — — — APPROX 2' OFF NEW CURB — — — — — — — — — TO REMAIN BY CONSTRUCTION- -- � w W w w w --------- -- --------- W W W �e e a� a e a / I / ADJACENT PROPERTY: PROPERTY LINE COMMERCIAL ZONING Landscape Plan scale 1" = 10'- 0" 0 10 I I I I I i PROPERTY LINE STONE SCHEDULE ROCK SYMBOL DESCRIPTION QTY 9 3' X 3' X 3' WEATHERED GRANITE BOULDER 3 (ED 4' X 6' GRANITE BOULDER 2 ® 24"X24" BLACK STONE PAVER 8 ROCK SYMBOL DESCRIPTION QTY LANDSCAPE NOTES l . PLANTING DIMENSIONS PROVIDED ON PLANS FOR PERMITTING PURPOSES ONLY. SEE CIVIL AND ARCHITECTURAL SITE PLANS FOR PARKING LOT LAYOUT. 6. SEE ARCHTECTURAL SITE PLAN FOR PARKING STALL COUNTS AND DIMENSIONS 7. FOR DETAILED GRADING, SEE CIVIL PLANS 8. PROVIDE AUTOMATIC IRRIGATION SYSTEM FOR ALL NEW PLANTINGS. EXISTING IRRIGATION SYSTEM TO BE CAPPED AND NEW AREAS TO BE RECONNECTED TO EXISTING. PROVIDE NEW WIRES, PIPES, VALVES, AND SPRINKLERS IN DISTURBED AREAS. ENSURE THAT EXISTING ZONES ARE OPERABLE. IRRIGATION TO BE INSTALLED PRIOR TO PLANTING. 9. ALL AREAS WITHIN LIMIT OF DISTURBANCE SHALL BE RESTORED. 10. PROVIDE GROUNDCOVERS IN ALL SHRUB PLANTING AREAS. GROUNDCOVERS SHALL BE SPACED USING A TRIANGULAR PATTERN, 18" O.C. OR AS NOTED. 11. ALL PLANTING LOCATIONS TO BE APPROVED BY LANDSCAPE ARCHITECT IN THE FIELD PRIOR TO PLANTING 12. PLANTING BEDS SHALL RECEIVE 3" OF COMPOST TILLED INTO 8" DEPTH, OR PLACE 8'' OF IMPORTED SOIL CONTAINING 35-40% COMPOST BY VOLUME (CEDAR GROVE 3-WAY TOPSOIL, OR o �$ PEBBLES 78 SF 2-3" DIA. DARK BEACH PEBBLES AVAIL FROM MARENAKOS ROCK CENTER, 425.392.3313 13. 2" MIN. DEPTH, 4" MAX. DEPTH PLANT SCHEDULE APPROVED EQUAL). . MULCH AFTER PLANTING WITH 2"-4" OR APPROVED EQUAL. OF DARK FINE FIR BARK MULCH QTY BOTANICAL NAME COMMON NAME SIZE COND 7 ACER CIRCINATUM VINE MAPLE 8-10' HT. B&B MULTI -STEM, MIN. 3 STEMS, 8-10' HT 2 CORNUS NUTTALII X FLORIDA 'EDDIE'S WHITE WONDER' EDDIE'S WHITE WONDER DOGWOOD 2'' CAL. B&B _ 1 LAGERSTROEMIA X 'TUSCARORA' RED CRAPE MYRTLE MULTI -TRUNK 2'' CAL. B&B / RELOCATED FROM PHASE 1 1 MAGNOLIA X 'ELIZABETH' ELIZABETH MAGNOLIA 2'' CAL. B&B 4 PSEUDOTSUGA MENZIESII DOUGLAS FIR 10' HT. B&B / 5 STEWARTIA PSEUDOCAMELLIA MULTI -STEM, MIN. 3 STEMS, 8-10' HT JAPANESE STEWARTIA 8-10' HT. B&B 3 ZELKOVA SERRATA VILLAGE GREEN' VILLAGE GREEN JAPANESE ZELKOVA 2" CAL. B&B BOTANICAL NAME COMMON NAME SIZE COND ZAh AZALEA X 'HINO CRIMSON' HINO CRIMSON AZALEA 5 GAL. CONT. S BUXUS MICROPHYLLA WINTER GEM' GLOBE WINTER GEM BOXWOOD 5 GAL. CONT. (c ILEX CRENATA 'CONVEXA' CONVEX -LEAVED JAPANESE HOLLY 5 GAL. CONT. Pc PIERIS JAPONICA 'CAVATINE' LILY OF THE VALLEY BUSH 5 GAL. CONT. Ri RHODODENDRON IMPEDITUM IMPEDITUM DWARF RHODODENDRON 5 GAL. CONT. Rn ROSA X 'NOASCHNEE' FLOWER CARPET WHITE GROUNDCOVER ROSE 5 GAL. CONT. Sb SPIRAEA JAPONICA 'DENISTAR' SPIREA 5 GAL. CONT. Ta TAXUS X MEDIA DENSE YEW 5 GAL. CONT. G VACCINIUM OVATUM EVERGREEN HUCKLEBERRY 5 GAL. CONT. SHRUB AREAS BOTANICAL NAME COMMON NAME SIZE COND SPACING EXISTING SHRUBS AND GROUNDCOVERS TO REMAIN INTERPLANT WITH ADDITIONAL GROUNDCOVERS BELOW EPIMEDIUM X PERRALCHICUM FRAGARIA CHILOENSIS GROUND COVERS BOTANICAL NAME LANDSCAPE BUFFER GROUNDCOVERS EPIMEDIUM X PERRALCHICUM MAHONIA REPENS POLYSTICHUM MUNITUM PACHYSANDRA MIX PACHYSANDRA TERMINALIS POLYSTICHUM SETIFERUM 00:(1011 00oMONDO FERN MIX 00 DRYOPTERIS ERYTH ROSORA OPHIOPOGON PLANISCAPUS 'NIGRESCENS' NATIVE MIX GAULTHERIA SHALLON MAHONIA REPENS POLYSTICHUM MUNITUM \ EXISTING HEDGE 1—� PLANTED BY WEATHERLY PROJECT BEACH STRAWBERRY COMMON NAME CREEPING MAHONIA WESTERN SWORD FERN 1 GAL. 50% @ 24" o.c. 4" POT CONT. 50% @ 24" o.c. SIZE COND SPACING 1 GAL. 33% @ 24" o.c. 1 GAL. POT 33% @ 24" o.c. 2 GAL. POT 33% @ 24" o.c. JAPANESE SPURGE 1 GAL SOFT SHIELD FERN 1 GAL AUTUMN FERN 1 GAL BLACK MONDO GRASS 1 GAL SALAL 1 GAL CREEPING MAHONIA 1 GAL WESTERN SWORD FERN 2 GAL to '-O Cr CV } O CO U 00 �o � °` co N CN _ O 00 o L N Cal N Q N N O (D U 3 � V) N V) Swanson Gardner Meyers Parking Lot Expansion 4512 Talbot Rd Renton, Washington Phase 3 Landscape Plan job name: RLAW scale: As Noted date: October 24, 2023 Civil Permit 6/6/2022 Land Use Permit 8/18/2022 Permit Correction 9/29/2022 Permit Correction 1 1 /18/2022 CONT. 66% @ 12" o.c. Permit Correction 2/2/2023 CONT. 33% @ 12" o.c. Permit Correction 8/1 1 /2023 L� CONT. 33% @ 18" o.c. CONT. 66% @ 18" o.c. CONT. 33% @ 24" o.c. POT 33% @ 24" o.c. POT 33% @ 24" o.c. F ENT PLANNING �,�rganroth [11 /1 /23] %jl issue: sheet: L 1 • date: