Loading...
HomeMy WebLinkAboutMFP24001972.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP24001972 IVR Number: 24001972 Permit Information Permit Name: JB0001475027 OSP DE KV13B - CUTOVER Address/Location:04/16/2024Application Date:3223059237Parcel Number: 10545 SE CARR RD Permit Type:05/02/2024Issue Date:Franchise Permit Work Class:05/02/2025Expiration Date:Major Utility Job Number: JB0001475027Franchise Type:Cable Description: Comcast proposes to replace hardware at aerial and UG locations. Contacts Name Address PhoneTypeBilling Ashley Kiehn 4610 Tacoma Avenue Sumner, WA 98390 ApplicantX Gayle Berner Mastec North America Inc. H: (000) 000-0000 C: (253) 364-9363 Applicant Rena Watts Comcast 1575 75th St SW, #200 Everett, WA 98203 B: (425) 977-9120 C: (425) 977-9120 Contact Mastec North America Inc 800 S Douglas Road, 1200 Coral Gables, FL 33134 Contractor Business License Number: 51687Construction Contractor: MASTENA991KJ MSALK #3 LLC 10545 SE CARR RD RENTON , WA 98055 Owner General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Gayle Berner 253-364-9363 4610 TACOMA AVE SUMNER, WA 98390 JB0001475027 OSP DE KV13B 10545 SE CARR RD, RENTON, WA 98055 5/16/2024 6/16/2024 9 AM 330 PM Mastec North America Comcast proposes to replace hardware at aerial and UG locations. MFP24001972 Monday - Friday Scott Warlick CED 5/2/2024 4/16/2024 Gayle Berner REVISIONSDATEDESCRIPTIONINITIALVICINITY KEY-MAP FOR TTC SET-UP1 11431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RF 7TCP-1 PERMIT - DESIGN 1KEY TAG# FOR TTC SET-UP SEE TCP SHEET #:SITE ADDRESS1.TYP./SIM. TTC SET-UP, SEE TCP-1 SHEET-210545 SE CARR RD2.TYP./SIM. TTC SET-UP, SEE TCP-2 SHEET-310583 SE CARR RD3.TYP./SIM. TTC SET-UP, SEE TCP-3 SHEET-417901 108th AVE SE17809 108th AVE SE4.TYP./SIM. TTC SET-UP, SEE TCP-2 SHEET-310810 SE 182nd ST18100 107th PL SE5.TYP./SIM. TTC SET-UP, SEE TCP-2 SHEET-318115 110th AVE SE6.TYP./SIM. TTC SET-UP, SEE TCP-2 SHEET-311203 SE 186th ST7.TYP./SIM. TTC SET-UP, SEE TCP-2 SHEET-311245 SE 186th ST11257 SE 186th ST18537 114th AVE SE8.TYP./SIM. TTC SET-UP, SEE TCP-2 SHEET-318600 116th AVE SE9.TYP./SIM. TTC SET-UP, SEE TCP-2 SHEET-318408 116th AVE SE10.TYP./SIM. TTC SET-UP, SEE TCP-6 SHEET-718134 116th AVE SE18204 116th AVE SE18226 116th AVE SE11.TYP./SIM. TTC SET-UP, SEE TCP-2 SHEET-311405 SE 182nd ST11431 SE 182nd ST12.TYP./SIM. TTC SET-UP, SEE TCP-2 SHEET-318006 116th AVE SE18004 116th AVE SE13.TYP./SIM. TTC SET-UP, SEE TCP-2 SHEET-318000 116th AVE SE14.TYP./SIM. TTC SET-UP, SEE TCP-2 SHEET-317906 116th AVE SE17830 116th AVE SE234511678910121314NOTE:·ALL TTC PLANS ARE TYPICAL / SIMILARTO ACTUAL ROAD CONDITIONS, ALLTTC DEVICES MAY HAVE MINIMALADJUSTMENTS IN FIELD ASDETERMINED BY THE FIELD TRAFFICCONTROL SUPERVISOR TO REFLECTTHE NEEDED TTC FOR WORKCONDITIONS.·WHERE USED, ADJACENT BUSINESSESAND/OR RESIDENT'S WILL BE NOTIFIEDIN WRITING 72 HRS IN ADVANCE OFPLACEMENT OF "NO PARKING" SIGNS.·REFER TO TTC SET-UP KEY-PLAN FORSET-UP ORIENTATION.·FIELD VERIFY ROAD SPEED ANDCOORDINATE TTC DEVICE SPACINGWITH DISTANCE CHARTS.TYP./SIM. TTC SET-UP, SEE TCP-3 SHEET-4TYP./SIM. TTC SET-UP, SEE TCP-4 SHEET-5HAROLD BROWNID: 7G73BCARD NO. IS 6 200067EXPIRES: 5/18/27MFP24001972 © 2023 Microsoft Corporation © 2023 Maxar ©CNES (2023) Distribution Airbus DS © 2023 TomTom ROWROWROWROWROWROWROWROWROWROWROWROWROWROWROW ROW ROW ROWROWSITE ADDRESS:10545 SE CARR RDREVISIONSDATEDESCRIPTIONINITIAL211431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RF 7TCP-1 Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSITE SPECIFIC-1ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE = BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--12125180245320540600660720780840WARNINGSIGN SYMBOLWARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERSAFETYVEHICLEWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.WORK VEHICLE SHOULDERWORKUTILITYWORKAHEADXXX UTILITYWORKAHEADX 11'MIN11'MINLIMITSPEEDR2-125HAROLD BROWNID: 7G73BCARD NO. IS 6 200067EXPIRES: 5/18/27MFP24001972 REVISIONSDATEDESCRIPTIONINITIAL311431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RF 7TCP-2 TYPICAL / SIMILAR WSDOT TTC SET-UPADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE = BSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--12125180245320540600660720780840WARNINGSIGN SYMBOLWARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERSAFETYVEHICLEWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.RURAL ROADS & URBAN ARTERIALS35 / 40 MPH350'  45 / 55 MPHRURAL ROADS500' 25 / 30 MPH200'  (2)URBAN STREETS25 MPH OR LESS100'  (2) 10550605660105125150205270165225295180245320540115-----7206607808402530354045505510'6040406570SHOULDERWIDTH(feet)16020022017019024015019013017012015040606090909060 / 65 MPHRURAL HIGHWAYSFREEWAYS & EXPRESSWAYS2530354050551260116570LANEWIDTH(feet)8'55 / 70 MPH800' LEGENDTEMPORARY SIGN LOCATIONTRAFFIC SAFETY DRUMTRANSPORTABLE ATTENUATORMPH50/7035/4525/30TAPERTANGENT403020806040RURAL ROADS & URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS1500' (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT-GRADE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.50055060049545045USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THEN 8'.SHOULDER WORK/SHOULDER CLOSEDSPEED (MPH)25303540455055606570LENGTH (feet)250305360425495570645730155200TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = RHOST VEHICLE WEIGHT9,900 TO 22,000 lbs.HOST VEHICLE WEIGHT> 22,000 lbs.SEE SPECIAL PROVISIONS FOR WORK HOUR RESTRICTIONS.EXTEND DEVICE TAPER AT L/3 ACROSS SHOULDER.DEVICES SHALL NOT ENCROACH INTO THE ADJACENT LANE.USE TRANSVERSE DEVICES IN CLOSED LANE EVERY 1000' (FT)(RECOMMENDED).DEVICE SPACING FOR THE DOWNSTREAM TAPER SHALL BE20' (FT).ALL SIGNS ARE BLACK ON ORANGE.1.2.3.4.5.6.NOTESWORK AREASHOULDERWORKSHOULDERWORKW21-5W21-5RIGHTSHOULDERCLOSEDRIGHTSHOULDERCLOSEDW21-5W21-5NOPARKINGFROMTOTOW-AWAY AREAPHONE (CONTACT #)NAME OF FIRM 000-0000NOPARKINGFROMTOTOW-AWAY AREAPHONE (CONTACT #)NAME OF FIRM 000-0000NOPARKINGFROMTOTOW-AWAY AREAPHONE (CONTACT #)NAME OF FIRM 000-0000AS NOTEDHAROLD BROWNID: 7G73BCARD NO. IS 6 200067EXPIRES: 5/18/27MFP24001972 REVISIONSDATEDESCRIPTIONINITIAL411431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RF 7TCP-3ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--12125180245320540600660720780840WARNINGSIGN SYMBOLWARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERSAFETYVEHICLEWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.1PCMSRURAL ROADS & URBAN ARTERIALS35 / 40 MPH350'  45 / 55 MPHRURAL ROADS500' 25 / 30 MPH200'  (2)URBAN STREETS25 MPH OR LESS100'  (2) PCMS10550605660105125150205270165225295180245320540115-----7206607808402530354045505510'6040406570SHOULDERWIDTH(feet)160200220170190240150190130170120150406060909090WORK AREA260 / 65 MPHRURAL HIGHWAYSFREEWAYS & EXPRESSWAYS2530354050551260116570LANEWIDTH(feet)8'55 / 70 MPH800' 1 MILEAHEADLEGENDTEMPORARY SIGN LOCATIONTRAFFIC SAFETY DRUMSEQUENTIAL ARROW SIGNTRANSPORTABLE ATTENUATORPORTABLE CHANGEABLE MESSAGE SIGNMPH50/7035/4525/30TAPERTANGENT403020806040RURAL ROADS & URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS1500' (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT-GRADE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.50055060049545045USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THEN 8'.SINGLE-LANE CLOSURE FOR MULTI-LANE ROADWAYSRIGHTLANECLOSUREFIELD LOCATE 1 MILE  INADVANCE OF LANE CLOSURE SIGNING.SPEED (MPH)25303540455055606570LENGTH (feet)250305360425495570645730155200TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = RHOST VEHICLE WEIGHT9,900 TO 22,000 lbs.HOST VEHICLE WEIGHT> 22,000 lbs.SEE SPECIAL PROVISIONS FOR WORK HOUR RESTRICTIONS.EXTEND DEVICE TAPER AT L/3 ACROSS SHOULDER.DEVICES SHALL NOT ENCROACH INTO THE ADJACENT LANE.USE TRANSVERSE DEVICES IN CLOSED LANE EVERY 1000' (FT)(RECOMMENDED).DEVICE SPACING FOR THE DOWNSTREAM TAPER SHALL BE20' (FT).ALL SIGNS ARE BLACK ON ORANGE.1.2.3.4.5.6.NOTES2' MIN.SEENOTE 4TYPICAL / SIMILAR WSDOT TTC SET-UPHAROLD BROWNID: 7G73BCARD NO. IS 6 200067EXPIRES: 5/18/27MFP24001972 REVISIONSDATEDESCRIPTIONINITIAL511431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RF 7TCP-4ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--12125180245320540600660720780840WARNINGSIGN SYMBOLWARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERSAFETYVEHICLEWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.LEGEND(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.URBAN STREETS35 / 40 MPH25 / 30 MPH45 / 55 MPH60 / 65 MPH50/65TAPERTANGENT10 TO 20MPHCHANNELIZATION DEVICESPACING (FEET)35/4525/3010 TO 2010 TO 20406080SIGN SPACING = X (1)RURAL HIGHWAYSRURAL ROADSRURAL ROADS & URBAN ARTERIALSRURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTS25 MPH OR LESS100'  (2)200'  (2)350'  500' 800'  ONE-LANE, TWO-WAY TRAFFIC CONTROLWITH FLAGGERS @ INTERSECTIONINTERSECTING ROADWAYW20-7B (OPTIONAL IF40 MPH OR LESS)W20-7B (OPTIONAL IF40 MPH OR LESS)W20-7B (OPTIONAL IF40 MPH OR LESS)FLAGGING STATIONTEMPORARY SIGN LOCATIONCHANNELIZING DEVICESPROTECTIVE VEHICLEWORKAREA1.2.3.4.50' TO 100'6 DEVICEMIN.50' TO 100'6 DEVICEMIN.50' TO300'NOTESALL SIGNS ARE BLACK ON ORANGE.EXTENDING THE CHANNELIZING DEVICE TAPER ACROSSSHOULDER IS RECOMMENDED.NIGHT WORK REQUIRES ADDITIONAL ROADWAY LIGHTING ATFLAGGING STATIONS. SEE THE STANDARD SPECIFICATIONSFOR ADDITIONAL DETAILS.SEE SPECIAL PROVISIONS FOR WORK HOUR RESTRICTIONS.SPEED (MPH)25303540455055606570LENGTH (feet)250305360425495570645730155200TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = RHOST VEHICLE WEIGHT9,900 TO 22,000 lbs.HOST VEHICLE WEIGHT> 22,000 lbs.PROTECTIVE VEHICLE (WORK VEHICLE) = RTYPICAL / SIMILAR WSDOT TTC SET-UPHAROLD BROWNID: 7G73BCARD NO. IS 6 200067EXPIRES: 5/18/27MFP24001972 REVISIONSDATEDESCRIPTIONINITIAL611431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RF 7TCP-5ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--12125180245320540600660720780840WARNINGSIGN SYMBOLWARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERSAFETYVEHICLEWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.LEGEND(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.URBAN STREETS35 / 40 MPH25 / 30 MPH45 / 55 MPH60 / 65 MPH50/65TAPERTANGENT10 TO 20MPHCHANNELIZATION DEVICESPACING (FEET)35/4525/3010 TO 2010 TO 20406080SIGN SPACING = X (1)RURAL HIGHWAYSRURAL ROADSRURAL ROADS & URBAN ARTERIALSRURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTS25 MPH OR LESS100'  (2)200'  (2)350'  500' 800'  ONE-LANE, TWO-WAY TRAFFIC CONTROLWITH FLAGGERS @ INTERSECTIONINTERSECTING ROADWAYW20-7B (OPTIONAL IF40 MPH OR LESS)W20-7B (OPTIONAL IF40 MPH OR LESS)W20-7B (OPTIONAL IF40 MPH OR LESS)FLAGGING STATIONTEMPORARY SIGN LOCATIONCHANNELIZING DEVICESPROTECTIVE VEHICLEWORKAREA1.2.3.4.50' TO 100'6 DEVICEMIN.50' TO 100'6 DEVICEMIN.50' TO300'NOTESALL SIGNS ARE BLACK ON ORANGE.EXTENDING THE CHANNELIZING DEVICE TAPER ACROSSSHOULDER IS RECOMMENDED.NIGHT WORK REQUIRES ADDITIONAL ROADWAY LIGHTING ATFLAGGING STATIONS. SEE THE STANDARD SPECIFICATIONSFOR ADDITIONAL DETAILS.SEE SPECIAL PROVISIONS FOR WORK HOUR RESTRICTIONS.SPEED (MPH)25303540455055606570LENGTH (feet)250305360425495570645730155200TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = RHOST VEHICLE WEIGHT9,900 TO 22,000 lbs.HOST VEHICLE WEIGHT> 22,000 lbs.PROTECTIVE VEHICLE (WORK VEHICLE) = RTYPICAL / SIMILAR WSDOT TTC SET-UPHAROLD BROWNID: 7G73BCARD NO. IS 6 200067EXPIRES: 5/18/27MFP24001972 REVISIONSDATEDESCRIPTIONINITIAL711431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RF 7TCP-6ADVANCED WARNING SIGN SPACINGROAD TYPESPEEDDISTANCE BETWEEN ADVANCEDWARNING SIGNSXXXXFREEWAYS & EXPRESSWAYS55/75 MPH1500 ±1500 ±1500 ±1500 ±RURAL HIGHWAYS60/65 MPH800 ±800 ±800 ±800 ±RURAL ROADS45/55 MPH500 ±500 ±500 ±500 ±RURAL ROADS & URBANARTERIAL35/40 MPH350 ±350 ±350 ±N/ARURAL ROADS, RESIDENTIAL &BUSINESS DISTRICTS25/30 MPH200 ± (2)200 ± (2)200 ± (2)N/AURBAN STREETS25 MPH ORLESS100 ± (2)100 ± (2)100 ± (2)N/A(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS,AT-GRADE INTERSECTIONS, AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.LONGITUDINAL BUFFER SPACE =LBSSPEED (MPH)2025303540455055606570DISTANCE (FT)115155200250305360425495570645730TAPER LENGTH IN FEET=L (FEET)LANEWIDTH(FEET)POSTED SPEED LIMIT (MPH)2530354045505560657010105150205270450500550---11115160225295495550605660--12125180245320540600660720780840WARNINGSIGN SYMBOLWARNING SIGNREGULATORY SIGNTRAFFIC CONEFLAGGER STATIONPATROL CARPOLICEOFFICERPOLICE OFFICERSAFETYVEHICLEWORK VEHICLELIT INTERSECTIONUNLIT INTERSECTIONSPOTTER STATIONKEEPRIGHT TCP DEVICE LEGENDFASFLASHING ARROWFLASHING DOUBLE ARROW(MERGE LEFT OR RIGHT)FLASHING CAUTIONFASFASFASTRAFFIC CONTROL PLAN GENERAL NOTES1.AN ARROWBOARD SHALL MEET THE MINIMUM SIZE,LEGIBILITY DISTANCE, NUMBER OF ELEMENTS ANDOTHER SPECIFICATIONS SHOWN.2.LENGTH OF ARROW EQUALS 48", WIDTH OFARROWHEAD EQUALS 24".3.TYPE A, B AND C ARROW BOARDS SHALL HAVESOLID RECTANGULAR APPEARANCES. A TYPE DARROW BOARD SHALL CONFORM TO THE SHAPE OFTHE ARROW.4.MAINTAIN DRIVEWAY ACCESS AT ALL TIMES5.SIDEWALK ARE EITHER OPEN OR NOT OPEN. ASIDEWALK IS CLOSED IF A MINIMUM 5' PATH CANNOTBE MAINTAINED MEASURED FROM PROPERTY LINE,OR 5.5' IF CREATED FROM FACE OF CURB.(PEDESTRIAN PATH PROVIDED WHERE REQUIRED)AND WILL BE MONITORED BY A SPOTTER TOENSURE FLOW AND SAFETY DURING WORK UNLESSOTHERWISE NOTED. A SPOTTER SHALL NOT DIRECTTRAFFIC.6.NO EXCEPTION TAKEN- CONTRACTOR ISRESPONSIBLE FOR ADA COMPLIANCE.7.ALL CONTROL SET-UP, SIGN SPACING ANDPROCEDURES. WILL CONFORM TO SPECIFICATIONSSTATED IN THE FEDERAL MANUAL ON UNIFORMEDTRAFFIC CONTROL DEVICES (M.U.T.C.D).8.CITIES AND VARIOUS MUNICIPALITIES MAY HAVEALSO ADOPTED SPECIALIZED GUIDELINES FORTRAFFIC CONTROL WITHIN THEIR JURISDICTION. ITIS THE RESPONSIBILITY OF THE ON-SITE TRAFFICCONTROL PERSONAL TO SEE IF AND ANY SPECIALCONDITIONS EXIST.9.FLAGGERS SHALL BE USED IN ACCORDANCE WITHWAC 468-95-302.10.IF ONLY ONE LANE IS OPEN IN A DIRECTION,THATLANE SHALL BE A MINIMUM OF 11' WIDE, UNLESSSPOTTER/FLAGGERS ARE USED, IN WHICH CASETHE LANE CAN BE A MINIMUM OF 10'.11.ALL ROW WORK MUST YIELD TO SCHOOL TRANSIT,EMPLOYEES AND CHILDREN. WHILE PASSENGERLOADING/UNLOADING, STOPPED OR SLOWING:CEASE WORK, YIELD. WHEN SCHOOL TRANSIT,AND/OR PEDESTRIANS, DEPART COMMENCE WORK.TYPICAL / SIMILAR WSDOT TTC SET-UPLEGEND (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.URBAN STREETS35 / 40 MPH25 / 30 MPH45 / 55 MPH60 / 65 MPH50/65TAPERTANGENT10 TO 20MPHCHANNELIZATION DEVICESPACING (FEET)35/4525/3010 TO 2010 TO 20406080SIGN SPACING = X (1)RURAL HIGHWAYSRURAL ROADSRURAL ROADS & URBAN ARTERIALSRURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTS25 MPH OR LESS100'  (2)200'  (2)350'  500' 800'  ONE-LANE, TWO-WAY TRAFFIC CONTROLWITH FLAGGERSW20-7B (OPTIONAL IF40 MPH OR LESS)W20-7B (OPTIONAL IF40 MPH OR LESS)FLAGGING STATIONTEMPORARY SIGN LOCATIONCHANNELIZING DEVICESPROTECTIVE VEHICLEWORKAREA1.2.3.4.50' TO 100'6 DEVICEMIN.50' TO 100'6 DEVICEMIN.50' TO300'NOTESALL SIGNS ARE BLACK ON ORANGE.EXTENDING THE CHANNELIZING DEVICE TAPER ACROSSSHOULDER IS RECOMMENDED.NIGHT WORK REQUIRES ADDITIONAL ROADWAY LIGHTING ATFLAGGING STATIONS. SEE THE STANDARD SPECIFICATIONSFOR ADDITIONAL DETAILS.SEE SPECIAL PROVISIONS FOR WORK HOUR RESTRICTIONS.SPEED (MPH)25303540455055606570LENGTH (feet)250305360425495570645730155200TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = RHOST VEHICLE WEIGHT9,900 TO 22,000 lbs.HOST VEHICLE WEIGHT> 22,000 lbs.PROTECTIVE VEHICLE (WORK VEHICLE) = R50' TO300'HAROLD BROWNID: 7G73BCARD NO. IS 6 200067EXPIRES: 5/18/27MFP24001972 SEFNCOCOMMUNICATIONSCOMCAST10545 SE CARR RD, RENTON, WA 98055JB00014750273 CAPACITY DIGITAL - WAKVD05800 1X2WAKVD05900 1X2 - WAKVD05700 2X4(KV13B 4X4) - RF(27) PROPOSED SPLICE LOCATIONS - FIBER INSTALLATIONMFP24001972This permit is for Major construction work in the ROW and will be billed at an additional$158/HR for inspections. After hours and weekend work will be billed at $175/HR CONTACTSPG#SHEET INDEX1COVER SHEET2VICINITY MAP, CONTACTS & SHEET INDEX3GENERAL NOTES4LEGEND5 - 18SITE-PLANDESCRIPTION OF WORKTOTAL(27) - PROPOSED SPLICE LOCATIONS - SEE VICINITY KEY-MAPFOR APPROXIMATE LOCATIONS0LFEND OF PERMIT DESIGN IN R.O.W.TOTAL:0LFVICINITY MAPSEFNCO - PERMITTINGASHLEY KIEHN4610 TACOMA AVESUMNER, WA 98390PHONE:253-999-2271EMAIL: ASKIEHN@SEFNCO.COM182R.O.W. PERMIT - DESIGNNTSREVISIONSDATEDESCRIPTIONINITIALCOMCAST - OPESEFNCO - OPE11431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RFJESSAMIN SANTOS410 VALLEY AVEPUYALLUP, WA 98371PHONE: (206) 401-2188Jessami_Santos@cable.comcast.comSTACEY PENNEWELL4610 TACOMA AVE.SUMNER, WA 98390253-457-0628spennewell@sefnco.com 1KEY TAG# SPLICE LOCATION SHEET #:SITE ADDRESS1.AERIAL SPLICE LOCATIONS, SEE SHEET-510545 SE CARR RD2.AERIAL SPLICE LOCATIONS, SEE SHEET-610583 SE CARR RD3.AERIAL SPLICE LOCATIONS, SEE SHEET-717901 108th AVE SE17809 108th AVE SE4.AERIAL SPLICE LOCATIONS, SEE SHEET-810810 SE 182nd ST18100 107th PL SE5.AERIAL SPLICE LOCATIONS, SEE SHEET-918115 110th AVE SE6.AERIAL SPLICE LOCATIONS, SEE SHEET-1011203 SE 186th ST7.AERIAL SPLICE LOCATIONS, SEE SHEET-1111245 SE 186th ST11257 SE 186th ST18537 114th AVE SE8.AERIAL SPLICE LOCATIONS, SEE SHEET-1218600 116th AVE SE9.AERIAL SPLICE LOCATIONS, SEE SHEET-1318408 116th AVE SE10.AERIAL SPLICE LOCATIONS, SEE SHEET-1418134 116th AVE SE18204 116th AVE SE18226 116th AVE SE11.AERIAL SPLICE LOCATIONS, SEE SHEET-1511405 SE 182nd ST11431 SE 182nd ST12.AERIAL SPLICE LOCATIONS, SEE SHEET-1618006 116th AVE SE18004 116th AVE SE13.AERIAL SPLICE LOCATIONS, SEE SHEET-1718000 116th AVE SE14.AERIAL SPLICE LOCATIONS, SEE SHEET-1817906 116th AVE SE17830 116th AVE SE234511678910121314MFP24001972 11431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RFGENERAL NOTES GENERAL NOTESTHE LOCATIONS OF UTILITIES SHOWN ON THESE DRAWING ARE ONLY APPROXIMATE. SEFNCO HEREBY DISCLAIMS ANYRESPONSIBILITY TO THIRD PARTIES FOR THE ACCURACY OF THIS INFORMATION. PERSONS WORKING IN THE AREACOVERED BY THIS DRAWING MUST CONTACT THE STATEWIDE CALL-BEFORE-YOU-DIG SYSTEM TO ASCERTAIN THELOCATION OF UNDERGROUND UTILITIES PRIOR TO PERFORMING ANY EXCAVATION.1.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEEDSITE WORK STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE LOCAL JURISDICTIONREGULATIONS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEENTHESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE HIGHER QUALITY STANDARDSHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIRE INSPECTED AND APPROVED BYTHE LOCAL JURISDICTION INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BEPROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.2.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTINGUTILITIES, AS SHOWN ON THESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND,WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED UPON ASBEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTING UTILITIES. THECONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTIONPOINTS AND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TORELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESEPLANS.3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLEAGENCIES. THE CONTRACTOR SHALL NOTIFY THE LOCAL JURISDICTION INSPECTOR AT LEAST 48 HOURS PRIORTO THE START OF ANY EARTH DISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLICIMPROVEMENTS IF REQUIRED.4.THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE LOCAL JURISDICTION AND ALL UTILITYCOMPANIES WITH REGARD TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURINGCONSTRUCTION, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUMDISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL PARTIESAFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.5.THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THEAPPROPRIATE STANDARDS AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSIONAGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALL TIMES.6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO:EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.7.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HISSUBCONTRACTORS, OR OTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOTIDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEERIMMEDIATELY.8.ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD,UNLESS SPECIFICALLY STATED OTHERWISE.9.FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE LOCAL JURISDICTION, THE CONTRACTORSHALL SUBMIT A TRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL.PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALLBE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY SAIDPLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BE HELD WITH LOCALJURISDICTION.10.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THECOMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BEPROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.11.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE ANDCLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.12.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORDDRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE LOCAL JURISDICTION INSPECTOR AT ALLTIMES.13.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONALINFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.14.ALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OFCONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED INGOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITHHARD SURFACE OR LANDSCAPING.15.ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE LOCAL JURISDICTIONENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.16.ALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNINGOF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATEDEQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVED BY THE LOCAL JURISDICTION.17.CALL THE "CALL BEFORE YOU DIG" NUMBER 48HRS IN ADVANCE AT 1-800-424-5555 PRIOR TO DIGGING.183R.O.W. PERMIT - DESIGNN/AREVISIONSDATEDESCRIPTIONINITIALMFP24001972 11431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEETOFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RFLEGEND 184R.O.W. PERMIT - DESIGN LEGENDTELECOMMUNICATIONSANITARY SEWERGAS LINEWATERSTORM DRAINRECYCLED WATERELECTRICALRAILROADRIGHT OF WAYDITCH LINECENTER LINEEDGE OF PAVEMENTFACE OF CURBPROPERTY LINELIP OF GUTTERGUARDRAILFENCESDSDWWSSSSGGEETTR/WLIPD/LEOPFOCRWRWTRENCHDIRECT BOREDBDBPROPOSED AERIAL OVERLASH PROPOSEDBASE LAYERSEXISTING UTILITIESEXISTING UTILITIES SYMBOLS POWER HANDHOLEPOWER MANHOLEPOWER CABINETSTREET LIGHT HANDHOLEPOWER SIDEWALK GUY SEWER CLEANOUTSTORM CATCH BASIN STORM MANHOLEWATER VALVEWATER METERTELECOM MANHOLETELECOM HANDHOLETELECOM CABINETTRAFFIC SIGNAL MANHOLETRAFFIC CABINETTRAFFIC SIGNAL PEDESTALPOWER VAULTSTREET LIGHT POLETRAFFIC SIGNAL VAULTTRAFFIC SIGNAL HANDHOLESIGN POSTPARKING METERCATV MANHOLECATV HANDHOLEPOWER PEDESTALGAS METERTEST VALVETRAFFIC LOOP DETECTORCATV PEDESTALBOLLARDWATER MANHOLETRAFFIC SIGNAL POLEPOWER GUYTRAFFIC DETECTORADA RAMPPEDESTAL(UNKNOWN UTILITY)MANHOLECULVERTFIRE HYDRANTGAS VALVE(UNKNOWN UTILITY)POWER ANCHORPOWER POLESEWER MANHOLETELECOM POLETELECOM PEDESTALPROPOSED VAULTPROPOSED PEDESTALPROPOSED MANHOLEPROPOSED SIDEWALK ANCHOR & GUYPROPOSED SYMBOLS ADA RAMP COMPLIANCEPEXISTING COMCAST VAULTEXISTING COMCAST SPLICEEXISTING COMCAST ANCHOREXISTING COMCAST GUYEXISTING COMCAST MANHOLEEXISTING COMCAST SIDEWALK ANCHOR & GUYP=VLP=GAS TEST POINTGAS MANHOLEPOWER UNKNOWN STORM CLEANOUTSTORM DRAIN VALVESTORM DRAIN UNKNOWN WATER UNKNOWNWATER WELLWATER PUMPWATER VAULTWATER RESERVOIRPPPPPP?PSLSLTSTSTSTSTSTSCCCTTTP=??TTSSSCSDD?DCDWWWWWVW?WELLPUMPGGGTLTLSEWER CATCH BASIN SSWATER SAMPLING STATIONOTHER UNKNOWNSTORM ACCESS POINTSEWER VALVESSEWER VAULT SSSEWER UNKNOWN S?SUB STATIONTRANSIT STOPSTORM DRAIN VAULT SDTREE PROPOSED RISEREXISTING COMCAST SYMBOLS BORE PITPROOF/PULLEXISTING COMCAST PEDPEXISTING COMCAST POLE W/ NEW RISERFMHMHBUILDING OUTLINEFLFOG LINEBUSSTOPTRENCHPSPLICE CASEPROPOSED AERIAL STORAGEEXISTING AERIAL STORAGE0'0'POTHOLESWSIDEWALK LINEPROPOSED AERIAL STRAND N/AREVISIONSDATEDESCRIPTIONINITIALMFP24001972 © 2023 Microsoft Corporation © 2023 Maxar ©CNES (2023) Distribution Airbus DS © 2023 TomTom ROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROW ROW ROW ROWROWSITE ADDRESS:10545 SE CARR RD11431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEET OFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RFSITE PLAN-1 10545 SE CARR RD51 18Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.R.O.W. PERMIT - DESIGNREVISIONSDATE DESCRIPTION INITIAL316502-166214MFP24001972 © 2023 Microsoft Corporation © 2023 Maxar ©CNES (2023) Distribution Airbus DS © 2023 TomTom ROWROWROWROWROWROWROW ROW ROW ROW ROW ROW ROW SITE ADDRESS:10583 SE CARR RD11431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEET OFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RFSITE PLAN-2 10583 SE CARR RD61 18Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.R.O.W. PERMIT - DESIGNREVISIONSDATE DESCRIPTION INITIAL1316487-166212316465-166211MFP24001972 © 2023 Microsoft Corporation © 2023 Maxar ©CNES (2023) Distribution Airbus DS © 2023 TomTom ROW ROW ROW ROW ROW ROW ROW ROWROWROWROWROWROWROWSITE ADDRESS:17809 108TH AVE SESITE ADDRESS:17901 108TH AVE SE11431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEET OFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RFSITE PLAN-3 17805 108TH AVE SE 17901 108TH AVE SE71 18Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.R.O.W. PERMIT - DESIGNREVISIONSDATE DESCRIPTION INITIAL1316443-166290316423-166291MFP24001972 © 2023 Microsoft Corporation © 2023 Maxar ©CNES (2023) Distribution Airbus DS © 2023 TomTom ROW ROW ROW ROW ROW ROW ROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWSITE ADDRESS:18100 107TH PL SESITE ADDRESS:10810 SE 182ND ST11431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEET OFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RFSITE PLAN-4 18100 107th PL SE 10810 182nd ST81 18Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.R.O.W. PERMIT - DESIGNREVISIONSDATE DESCRIPTION INITIAL1316338-166291316334-166311MFP24001972 © 2023 Microsoft Corporation © 2023 Maxar ©CNES (2023) Distribution Airbus DS © 2023 TomTom ROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROW ROW ROW ROWROWROWROWROWROWROWROWSITE ADDRESS:18115 110TH AVE SE11431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEET OFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RFSITE PLAN-5 18115 110TH AVE SE91 18Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.R.O.W. PERMIT - DESIGNREVISIONSDATE DESCRIPTION INITIAL316333-16636MFP24001972 © 2023 Microsoft Corporation © 2023 Maxar ©CNES (2023) Distribution Airbus DS © 2023 TomTom ROWROWROWROWROWROWROWROWROWROWROW ROWROWROWROWROWROW ROW ROW ROWROWROWROWROWSITE ADDRESS:11203 SE 186TH ST11431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEET OFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RFSITE PLAN-6 11203 SE 186TH ST101 18Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.R.O.W. PERMIT - DESIGNREVISIONSDATE DESCRIPTION INITIAL316210-166425MFP24001972 © 2023 Microsoft Corporation © 2023 Maxar ©CNES (2023) Distribution Airbus DS © 2023 TomTom ROWROWROWROWROWROWROWR O W ROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWROWSITE ADDRESS:18537 114TH AVE SESITE ADDRESS:11257 SE 186TH STSITE ADDRESS:11245 SE 186TH ST11431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEET OFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RFSITE PLAN-7 11245 SE 186TH ST 11257 SE 186TH ST111 18Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.APPROXIMATE GROUND SPLICE LOCATION.R.O.W. PERMIT - DESIGNREVISIONSDATE DESCRIPTION INITIAL122316210-166470316209-166486MFP24001972 © 2023 Microsoft Corporation © 2023 Maxar ©CNES (2023) Distribution Airbus DS © 2023 TomTom ROWROWROWROWROWROWROWROWROWROWROWROWROWROW ROW ROW ROW ROW ROW ROW ROWROWROWROWSITE ADDRESS:18600 116TH AVE SE11431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEET OFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RFSITE PLAN-8 18600 116TH AVE SE12 18Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.R.O.W. PERMIT - DESIGNREVISIONSDATE DESCRIPTION INITIAL1316206-166557MFP24001972 © 2023 Microsoft Corporation © 2023 Maxar ©CNES (2023) Distribution Airbus DS © 2023 TomTom ROWROWROWROWROWROWROWROWROW ROW ROWROWROWROW ROW ROWROWROWROWROWROWROW ROW ROW ROWROWROWROWROWSITE ADDRESS:18408 116TH AVE SE11431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEET OFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RFSITE PLAN-9 18408 116TH AVE SE13 18Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.R.O.W. PERMIT - DESIGNREVISIONSDATE DESCRIPTION INITIAL1316260-166558MFP24001972 © 2023 Microsoft Corporation © 2023 Maxar ©CNES (2023) Distribution Airbus DS © 2023 TomTom ROWROWROWROWROWROWROWROW ROW ROW ROW ROW ROW ROWROWSITE ADDRESS:18226 116TH AVE SESITE ADDRESS:18204 116TH AVE SESITE ADDRESS:18134 116TH AVE SE11431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEET OFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RF SITE PLAN-10 18134 116TH AVE SE 18204 116TH AVE SE 18226 116TH AVE SE14 18Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.R.O.W. PERMIT - DESIGNREVISIONSDATE DESCRIPTION INITIAL1111316327-166559316321-166559316307-166559316296-166559MFP24001972 © 2023 Microsoft Corporation © 2023 Maxar ©CNES (2023) Distribution Airbus DS © 2023 TomTom ROWROW ROWROWROWROWROWROWROW ROWROWROWROWROWROWROWROWROWROWROWROWSITE ADDRESS:11405 SE 182ND STSITE ADDRESS:11431 SE 182ND ST11431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEET OFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RFSITE PLAN-11 11405 SE 182ND ST 11431 SE 182ND ST15 18Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.R.O.W. PERMIT - DESIGNREVISIONSDATE DESCRIPTION INITIAL11316327-166493316327-166528MFP24001972 © 2023 Microsoft Corporation © 2023 Maxar ©CNES (2023) Distribution Airbus DS © 2023 TomTom © 2023 Microsoft Corporation © 2023 Maxar ©CNES (2023) Distribution Airbus DS © 2023 TomTom ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW SITE ADDRESS:18006 116TH AVE SESITE ADDRESS:18004 116TH AVE SE11431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEET OFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RFSITE PLAN-12 18006 116TH AVE SE 18004 116TH AVE SE16 18Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.R.O.W. PERMIT - DESIGNREVISIONSDATE DESCRIPTION INITIAL111316371-166560316362-166560316350-166560MFP24001972 © 2023 Microsoft Corporation © 2023 Maxar ©CNES (2023) Distribution Airbus DS © 2023 TomTom © 2023 Microsoft Corporation © 2023 Maxar ©CNES (2023) Distribution Airbus DS © 2023 TomTom ROW ROW ROWROWROWROWROWROWROWROWROWROWROWROWROWROWROW ROW ROW ROW ROWROWROWROW SITE ADDRESS:18000 116TH AVE SE11431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEET OFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RFSITE PLAN-13 18000 116TH AVE SE17 18Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.R.O.W. PERMIT - DESIGNREVISIONSDATE DESCRIPTION INITIAL11316381-166560316391-166561MFP24001972 © 2023 Microsoft Corporation © 2023 Maxar ©CNES (2023) Distribution Airbus DS © 2023 TomTom ROWROWROWROWROWROWROWROW ROW ROW ROW ROW ROWROWROWROWROWROWROW SITE ADDRESS:17906 116TH AVE SESITE ADDRESS:17830 116TH AVE SE11431 SE 182ND ST, RENTON, WA 98055 JB0001475027 COMCASTSHEET OFDATE:EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT,THESE DRAWINGS AND SPECIFICATIONS SHALL REMAIN THEPROPERTY OF SEFNCO COMMUNICATION, INC. BOTH BEINGISSUED IN STRICT CONFIDENCE AND SHALL NOT BEREPRODUCED, COPIED, OR USED FOR ANY PURPOSEWITHOUT SPECIFIC WRITTEN PERMISSION.SITE NAME:SCALELOCATION ADDRESS: COMCAST JOB NUMBER: STAMPDRAWN BY:SEFNCOCOMMUNICATIONSHBB11/6/20233 CAPACITY DIGITAL - WAKVD05800 1X2 WAKVD05900 1X2 - WAKVD05700 2X4 (KV13B 4X4) - RFSITE PLAN-14 17906 116TH AVE SE 17830 116TH AVE SE18 18Know what'sbelow.CallR81148 HOURS BEFORE YOU DIGUNDERGROUND SERVICE ALERTCALL TOLL FREEDIGALERTbefore you dig.NSCOPE OF WORK1APPROXIMATE AERIAL SPLICE LOCATION.R.O.W. PERMIT - DESIGNREVISIONSDATE DESCRIPTION INITIAL11316413-166561316439-166562MFP24001972