HomeMy WebLinkAboutMFP24002150.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP24002150
IVR Number: 24002150
Permit Information
Permit Name: P.182010
Address/Location:04/24/2024Application Date:7224500315Parcel Number: 546 BURNETT AVE N
Permit Type:05/09/2024Issue Date:Franchise
Permit Work Class:05/09/2025Expiration Date:Minor Utility
Job Number: P.182010Franchise Type:Telephone
Description: PSE REPLACED A PSE OWNED POLE 318236 166068. PSE HAS ALREADY PULLED THE OLD POLE. LUMEN HAS
A 200X COPPER CABLE THAT HAS BEEN TRANSFERRED TO THE NEW POLE. LUMEN HAS A 50X COPPER
CABLE THAT CAME DOWN THE OLD POLE & CONTINUES EAST AS A BURIED PATH. LUMEN WILL PLACE A NEW
50X COPPER CABLE ATOP THE NEW POLE, INSTALL A RISER ON THE NEW POLE, AND CREATE A NEW BURIED
SPLICE. LUMEN WILL EXPOSE THE GROUND AROUND THE NEW POLE AS PART OF THIS JOB AND WILL PLACE
COLD MIX OVER THE GROUND DISTURBANCE CREATED BY THE CABLE
RELOCATION. ONCE LUMEN HAS THIS WORK COMPLETED, PSE WILL DO HARD SURFACE RESTORATION ON
THE SIDEWALK THAT THE OLD POLE AND NEW POLE ARE LOCATED. JOB IS @ 581 BURNETT AVE N, WITHIN
THE RENTON MAIN WIRE CENTER
Contacts
Name Address PhoneTypeBilling
Merilyn Luong
Lumen
H: (206) 806-7160Applicant
Nathan Macleod
Lumen
7850 S Trafton St, Bldg B
Tacoma, WA 98409
C: (253) 583-6283ApplicantX
Michael Smith
North Sky Communications
21320 84th Ave S
Kent, WA 98032
C: (206) 305-5881Contractor
Business License Number: 36846Construction Contractor: NORTHSC857Q4
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
QWest/Century Link - Billing 23315 66th Ave S
Kent, WA 98032
Specialized
Billing
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
DEPARTMENT OF PUBLIC WORKS
Page 1 of 3 | Published: 3/18/2021
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN APPLICATION
Published: 3/18/2021
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control
plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents.
2. The following items are all required for submittal of the TCP Application:
☐ Electronic Copy of the TCP Application
☐ Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall:
▪ Include map(s) showing the location of the project and work area.
▪ Be legible lettering and clear, contrasting, symbols of viewing or printing.
▪ Must indicate street names, and north arrow and scale.
▪ Types of plans required:
o Work hour plan – show all mobility impacts during construction hours.
o Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
o Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
o Pedestrian access/detour plan, if applicable.
- Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the
Evergreen Safety Council.
3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].”
Project Name: Permit #:
Site Address:
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Construction Company:
Contact Name: Phone/Cell: _________________________
Business Address: City/State: Zip:
Description of Work:
Approval By: _________________________________________________ Date:____________________
Transportation Engineering
P.182010
5/20/2024 5/23/2024 8AM 5PM
Northsky Communications
Mike Smith
LUMEN HAS A 200X COPPER CABLE THAT HAS BEEN TRANSFERRED TO THE NEW POLE. LUMEN HAS A 50X COPPER CABLE THAT CAME DOWN THE OLD
POLE & CONTINUES EAST AS A BURIED PATH. LUMEN WILL PLACE A NEW 50X COPPER CABLE ATOP THE NEW POLE, INSTALL A RISER ON THE NEW POLE,
AND CREATE A NEW BURIED SPLICE. LUMEN WILL EXPOSE THE GROUND AROUND THE NEW POLE AS PART OF THIS JOB AND WILL PLACE COLD MIX
OVER THE GROUND DISTURBANCE CREATED BY THE CABLE
RELOCATION.
546 BURNETT AVE N
16701 SE McGillivrary Blvd Vancouver WA 98683-3462
425-615-7121
Monday - Friday 8:00AM - 3:00PM
MFP24002150
Scott Warlick CED 5/9/2024
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 3 | Published: 3/18/2021
PERMIT HOLDER AGREES TO ALL THE FOLLOWING:
• Must have approved Traffic Control Plan (TCP) prior to commencing the work.
• Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time,
with the least possible inconvenience or delay to pedestrians.
• WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the
traveled way.
• Comply with all traffic regulations of the City of Renton and the State of Washington.
• Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street
and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control
Devices.
• Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
• Any lane or street closures not in conformance with the approved traffic control plan and/or without notification
of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at
thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
• Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles and
the acts of the Permit Holder’s agents and employees.
• The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in
such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable
attorney’s fees and litigation costs incurred resulting from such claim.
• In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for
legal counsel chosen by the City to defend against same.
• Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
• All permit conditions shall be met.
NOTES:
• Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
• Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by a traffic control plan layout or reference to WSDOT.
• Approved Temporary Traffic Control Plan must be at the work site during work hours.
• Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public
transit, to be affected by a temporary lane or road closure.
• Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
• Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery
road conditions during work and non-work hours.
• Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company
logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous
place on the vehicle or equipment.
• In the case of Temporary No Parking Zones, all the following apply in addition to previous:
• Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
• Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 3 of 3 | Published: 3/18/2021
• The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
• Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555
NE 2nd Street).
I certify that the information on this application and within the submittal documents are accurate to the best of my
knowledge and I acknowledge all the requirements on this application.
Applicant’s Signature Date
Applicant’s Name (Print)
Merilyn Luong
4/24/2024
Traffic Control PlannerElite Traffic Solutions206-922-9205julian@elitetrafficsolutions.comRentonKingP.182010 98057 COVER SHEET
BUFFER DATALONGITUDINAL BUFFER SPACE = BSPEED (MPH)LENGTH (FEET)25 30 35 40 45 50 55 60 65 70155200250305360425495570645730
MINIMUM SHOULDER TAPER LENGTH (L/3) (FEET)ShoulderWidthFeet Posted Speed (mph)10 25 30 35 40 45 50 55 60 65 7040404060609090901201501301701501902008160170190240220USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THEN 8'.
(1) All spacing may be adjusted to accommodate interchange ramps, at-grade intersections, and driveways.(2) This spacing may be reduced in urban areas to fit roadway conditions.
RURAL HIGHWAYSRURAL ROADSRURAL ROADS & URBAN ARTERIALSRURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSURBAN STREETSALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED.
60/65 MPH45/55 MPH35/40 MPH25/30 MPH25 MPH OR LESS 800'SIGN SPACING=X (FEET) (1)500'350'200'100'(2)(2)
FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR ASPER MUTCD)
CHANNELIZING DEVICE SPACING (FEET)MPH TAPER TANGENT50/7035/4525/30 403020 806040
Scope of Work: Pole WorkTraffic Control Plan:Shoulder Closure
All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT"Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards.
Standard Notes:1. Reserve curb space with Traffic Permits 684-5086 in Pay Station blocks2. Haul Routes to be submitted to Don Smith, City Truck Officer, don.smith@seattle.gov3. Metro trolley coaches cannot shift more than 9' from the center of their overhead lines.Contact Metro Trolley at 477-1150 or trolley.impacts@kingcounty.gov.For Metro non-trolley coach or other transit agency relocations contact 477-1140 orconstruction.coord@kingcounty.gov4. Sidewalks are either open or not open.A sidewalk is closed if a minimum 4' path cannot be maintained measured from property line,or 5 ½' if created from face of curb5. Standard Advance Warning Signs shall be used for plates orrough road during after-hours, including “Motorcyclist” sign6. If only one lane is open in a direction, that lane shall be a minimum of 11' wide,unless spotter/flaggers are used, in which case the lane can be a minimum of 10'7. Flaggers shall be used in accordance with WAC 468-95-302.UPO will be required if a traffic signal could be countermanded
SHEET 1PPOLE-A0509513
REVISED04/23/2024 by:Elite Traffic Solutions206.922.9205Julian MoralesTCS #012813Exp.4/30/2025Juʙiʋn Morales
www.invarion.com
MFP24002150
Traffic Control PlannerElite Traffic Solutions206-922-9205julian@elitetrafficsolutions.comRentonKingP.182010 98057 01 OF 01
LegendPA0509513ConeSign StandSSpotterWork Area
BUFFER DATALONGITUDINAL BUFFER SPACE = BSPEED (MPH)LENGTH (FEET)25 30 35 40 45 50 55 60 65 70155200250305360425495570645730
MINIMUM SHOULDER TAPER LENGTH (L/3) (FEET)ShoulderWidthFeet Posted Speed (mph)10 25 30 35 40 45 50 55 60 65 7040404060609090901201501301701501902008160170190240220USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THEN 8'.
(1) All spacing may be adjusted to accommodate interchange ramps, at-grade intersections, and driveways.(2) This spacing may be reduced in urban areas to fit roadway conditions.
RURAL HIGHWAYSRURAL ROADSRURAL ROADS & URBAN ARTERIALSRURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSURBAN STREETSALL SIGNS ARE 48'' X 48'' BLACK ON ORANGE UNLESS OTHERWISEDESIGNATED.
60/65 MPH45/55 MPH35/40 MPH25/30 MPH25 MPH OR LESS 800'SIGN SPACING=X (FEET) (1)500'350'200'100'(2)(2)
FREEWAYS & EXPRESSWAYS 55/70 MPH 1500 (OR ASPER MUTCD)
CHANNELIZING DEVICE SPACING (FEET)MPH TAPER TANGENT50/7035/4525/30 403020 806040
Scope of Work: Pole WorkTraffic Control Plan:Shoulder Closure
546 BURNETT AVE N
N 6TH ST35MPH
All Signs & Spacing to conform to the MUTCD Standards-reference WSDOT"Work Zone Traffic Control Guidelines M54-44.04 January 2021" & The City of Renton's Standards.LOGAN AVE N25MPH
Plan Scale1 : 600 (1'' = 50')
BURNETT AVE N25MPH
532 BURNETT AVE N
General Notes:1. All signs and spacing shall conform to The MUTCD and WAC.2. Priority passage through the work area for emergencyvehicles vehicles shall be provided at all times.3. Alert Metro Transit 5 days in advance4. Protective vehicle recommended may be a work vehicle.5. Devices should not encroach into adjacent lanes.6. All signs min. 48 x 48 B/O unless otherwise specified.7. Channelization devices are 28" reflective cones8. All sign spacing may be adjusted to accommodate at-gradeintersections and/or driveways.9. Traffic Control Supervisor required for ROW impacts.
P POLE-A050951328'10'10'8'35'S SPOTTER SHALL ASSIST PEDESTRIANSTHROUGH WORKZONE SAFELY.
XX ROADWORKAHEAD
SHOULDERCLOSED
ROADWORKAHEAD
80'NO PARK24 HRS NOPARKINGFROMTOTOW AWAY AREAPHONE 685-5444YOUR COMPANY NAME 555-5555R7-T39L/3
REVISED04/23/2024 by:Elite Traffic Solutions206.922.9205Julian MoralesTCS #012813Exp.4/30/2025Juʙiʋn Morales
www.invarion.comMFP24002150
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB: BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:GEO CODE: WC CLLI:TOTAL EXISTING CONDUIT USED:TOTAL NEW BORE:TOTAL NEW DIRT TRENCHESTIMATED TOTALSTOTAL NEW AERIAL:SIDEWALK (PCC) R&R:ASPHALT (AC) R&R:S.F.S.F.L.F.L.F.L.F.L.F.TOTAL NEW ASPHALT TRENCH:L.F.TOTAL NEW S/W TRENCH:L.F.00000000”NVICINITY MAPSL581 BURNETT AVE NRENTON, WA 98057P.182010W26852RNTNWA0123N5E804/01/2431®CUSTOMER NAME: N/ALCON: N/APHONE: N/AEMAIL: N/AWFMT #: N/AORDER #: NAARMOR OR DSR #: N/ASCOPE OF WORK:PSE REPLACED A PSE OWNED POLE 318236-166068. PSE HAS ALREADY PULLED THE OLD POLE. LUMEN HAS A 200X COPPER CABLE THAT HAS BEEN TRANSFERRED TO THE NEW POLE. LUMEN HAS A 50X COPPER CABLE THAT CAME DOWN THE OLD POLE & CONTINUES EAST AS A BURIED PATH. LUMEN WILL PLACE A NEW 50X COPPER CABLE ATOP THE NEW POLE, INSTALL A RISER ON THE NEW POLE, AND CREATE A NEW BURIED SPLICE. LUMEN WILL EXPOSE THE GROUND AROUND THE NEW POLE AS PART OF THIS JOB AND WILL PLACE COLD MIX OVER THE GROUND DISTURBANCE CREATED BY THE CABLE RELOCATION. ONCE LUMEN HAS THIS WORK COMPLETED, PSE WILL DO HARD SURFACE RESTORATION ON THE SIDEWALK THAT THE OLD POLE AND NEW POLE ARE LOCATED. JOB IS @ 581 BURNETT AVE N, WITHIN THE RENTON MAIN WIRE CENTER.SH OF DRAFTED BY: MOUNTAIN LTD/MT LTD ENGINEER: N/APHONE NO: N/AEMAIL: N/AFIBER ENGINEER: BILLY C. HERNANDEZPHONE NO: 253-458-6549EMAIL: Kaleb.ConkleHernandez@lumen.comMFP24002150
TT
T
T
TEE
E
E
E CATV CATV CATV
CAT
V
CAT
V
CAT
V
CAT
V
CAT
V GG
GGG TS TS
TS
TS
TS WWWWW S S
S
S S
SD SD
SD
SD
SD C/L C/L C/L
C/L
C/L
C/L
R/W R/W
R/W
R/W
R/W
R/W
R/W
P/L P/L
P/L
P/L
P/L
P/L
B/C B/C B/C B/C
B/
C
B/
C
B/C
B/C
EOP EOP
EOP
EOP
EOP
TTTUSAMEEPWREE CATV
CATV TVTV CATV
CATV CATV
CATV
CATV
CATV CATV
CATV VTS C/L C/L VWSSDVETTTXXX'XXX'XXX'XXX'X IRRIG IRRIG F1NOTICE-NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB: RNGE:SECT:TOWN:GEO CODE: WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:JOB:GEO CODE:WC CLLI:DRAFTED BY: MOUNTAIN LTD/SH OF SL581 BURNETT AVE NRENTON, WA 98057P.182010W26852RNTNWA0123N5E804/01/2432®MT LTD ENGINEER: N/APHONE NO: N/AEMAIL: N/AFIBER ENGINEER: BILLY C. HERNANDEZPHONE NO: 253-458-6549EMAIL: Kaleb.ConkleHernandez@lumen.comMFP24002150
NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYEDOR TIED. RIGHT-OF-WAY LOCATION IS ASSUMED WITHREFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGHTS OF WAY AND/OREASEMENTS PRIOR TO CONSTRUCTION. EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP STATION PSEPROPOSED HOA318236-166068TRANSFERPOLE NUMBER(S) - LMN/PWR/OTHER - A0509513SPLICE NEW 50X, PLACE NEW RISER, CREATE BURIED SPLICE, PLACE COLD MIX AS TEMPORARY RESTORATION. PSE TO DO HARD SURFACE RESTORATION ONCE LUMEN WORK IS COMPLETED.N/A1NOTE:PSE REPLACED A PSE OWNED POLE 318236-166068. PSE HAS ALREADY PULLED THE OLD POLE. LUMEN HAS A 200X COPPER CABLE THAT HAS BEEN TRANSFERRED TO THE NEW POLE. LUMEN HAS A 50X COPPER CABLE THAT CAME DOWN THE OLD POLE & CONTINUES EAST AS A BURIED PATH. LUMEN WILL PLACE A NEW 50X COPPER CABLE ATOP THE NEW POLE, INSTALL A RISER ON THE NEW POLE, AND CREATE A NEW BURIED SPLICE. LUMEN WILL EXPOSE THE GROUND AROUND THE NEW POLE AS PART OF THIS JOB AND WILL PLACE COLD MIX OVER THE GROUND DISTURBANCE CREATED BY THE CABLE RELOCATION. ONCE LUMEN HAS THIS WORK COMPLETED, PSE WILL DO HARD SURFACE RESTORATION ON THE SIDEWALK THAT THE OLD POLE AND NEW POLE ARE LOCATED. JOB IS @ 581 BURNETT AVE N, WITHIN THE RENTON MAIN WIRE CENTER.OLDBURNETT AVE N.
SIDEWALK
LOGAN AVE N.SIDEWALK
NEWNOTICE-NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB: GEO CODE: WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSSL581 BURNETT AVE NRENTON, WA 98057P.182010W26852RNTNWA0123N5E804/01/2433RSH OF DRAFTED BY: MOUNTAIN LTD/MT LTD ENGINEER: N/APHONE NO: N/AEMAIL: N/AFIBER ENGINEER: BILLY C. HERNANDEZPHONE NO: 253-458-6549EMAIL: Kaleb.ConkleHernandez@lumen.comMFP24002150