Loading...
HomeMy WebLinkAboutBig Liberty elec - ballfield lights E1.1 1.5.09PANEL SCHEDULEPANEL:NLOCATION:SWITCHBOARD ENCLOSUREVOLTS:480 Y/277P3W:4AMP:400MLO MCB XAIC RATING:14,000MOUNT: SURFACE FLUSHTYPE: EXISTING XNEW STYLE:NEUTRAL:100%FED FROM:MAIN SERVICE LOAD LOAD CKT P CIR P CIR P CKT LOAD LOADCIRCUIT DESCRIPTIONTYPE KVA BKR # H # BKR KVA TYPECIRCUIT DESCRIPTIONFUTURE PARKING LOT LIGHTS 30 31A23 30 FUTURE BASKETBALL LIGHTS- - -3B4- - -- - -5C6- - -EXIST SKATE PARK LIGHTS 50 37A83 50 EXIST SKATE PARK LIGHTS- - -9B10- - -- - -11C12- - -NEW BASEBAL FIELD LIGHTS - POLES A2, B2 (NOTE 1)LTG 10.2450 313A143 6012.29 LTGNEW BASEBAL FIELD LIGHTS - POLES C1,C2,D1,D2 (NOTE 1)-LTG 10.24- -15B16- -12.29 LTG--LTG 10.24- -17C18- -12.29 LTG-NEW BASEBAL FIELD LIGHTS - POLE B1 (NOTE 1)LTG 6.1530 319A203 204.10 LTGNEW BASEBAL FIELD LIGHTS - POLE A1 (NOTE 1)-LTG 6.15- -21B22- -4.10 LTG--LTG 6.15- -23C24- -4.10 LTG-SPACE 25A26 SPACE 27B28 SPACE 29C30 SPACE 31A32 SPACE 33B34 SPACE 35C36 SPACE 37A38 SPACE 39B40 SPACE 41C42 DEMAND CALCULATIONSLOAD SUMMARY: LOAD TYPE: CONNECTED CALCULATION DEMAND LIGHTINGLTG98.34 KVA 122.93 KVA (125%) CONNECTED PHASE LOADING RESIDENT LTG/RECPTRLTG0.00 KVA 0.00 KVA ( 100/35/25 %)PHASE A:32.78 KVASMALL APPLIANCEAPL0.00 KVA 0.00 KVA ( 100/35/25 %)PHASE B:32.78 KVALARGEST MOTORLGST0.00KVA 0.00 KVA (125%)PHASE C:32.78 KVAREMAINING MOTORSMTR0.00 KVA 0.00 KVA (100%)Total Connected Load =98.34 <= includes double lug loadsGEN PURPOSE RECPTREC0.00 KVA 0.00 KVA ( 50% > 10KVA)Load Checker Total =98.34 <= includes double lug loadsCOMPUTER RECPTCOMP0.00 KVA 0.00 KVA (100%)EQUIP/OTHERMISC0.00 KVA 0.00 KVA (100%)HEATINGHTG0.00 KVA 0.00 KVA (100%)NOTES:ELEVATORELEV0.00 KVA 0.00 KVA @100%1 PROVIDE NEW BREAKERS, RETURN EXISTING BREAKERS TO OWNERKITCHEN EQPTKIT0.00 KVA 0.00 KVA @65%------------- -----------------TOTALS98.34 KVA 122.93 KVA118.28 AMPS 147.86 AMPSLOAD TYPE NOTES: "LGST" =LARGEST MOTOR SHOULD BE ENTERED MANUALLY AT END OF PROJECT"RES" = RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE LOAD TAKEN AT INDICATED DEMAND"MISC" = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED CIRCUIT AT 100%PANEL SCHEDULEPANEL:MLOCATION:SWITCHBOARDVOLTS:480 Y/277P3W:4AMP:400MLO MCB XAIC RATING:14,000MOUNT: SURFACE FLUSHTYPE: EXISTING XNEW STYLE:NEUTRAL:100%FED FROM:MAIN SERVICE LOAD LOAD CKT P CIR P CIR P CKT LOAD LOADCIRCUIT DESCRIPTIONTYPE KVA BKR # H # BKR KVA TYPECIRCUIT DESCRIPTIONEXIST SOFTBALL FIELD POLES A1, A2LTG 3.6050 31A23 503.60 LTGEXIST SOFTBALL FIELD POLE B1-LTG 3.60- -3B4- -3.60 LTG--LTG 3.60- -5C6- -3.60 LTG-EXIST SOFTBALL FIELD POLE B2LTG 3.6050 37A83 504.80 LTGEXIST SOFTBALL FIELD POLE C1-LTG 3.60- -9B10- -4.80 LTG--LTG 3.60- -11C12- -4.80 LTG-EXIST SOFTBALL FIELD POLE C2LTG 4.8050 313A143 503.60 LTGEXIST TENNIS COURT POLES T1, T2, T4, T6-LTG 4.80- -15B16- -3.60 LTG--LTG 4.80- -17C18- -3.60 LTG-SPACE 19A203 503.60 LTGEXIST TENNIS COURT POLES T3, T5, T7, T8SPACE 21B22- -3.60 LTG-SPACE 23C24- -3.60 LTG-SPACE 25A26 SPACESPACE 27B28 SPACESPACE 29C30 SPACESPACE 31A32 SPACESPACE 33B34 SPACESPACE 35C36 SPACEEXIST SECURITY LIGHTSLTG 1.0030 337A38 SPACE-LTG 1.00- -39B402 5030.04 COMBPANEL H VIA 50KVA TRANSFORNER-LTG 1.00- -41C42- -27.36 COMB-DEMAND CALCULATIONSLOAD SUMMARY: LOAD TYPE: CONNECTED CALCULATION DEMAND LIGHTINGLTG85.80 KVA 107.25 KVA (125%) CONNECTED PHASE LOADING RESIDENT LTG/RECPTRLTG0.00 KVA 0.00 KVA ( 100/35/25 %)PHASE A:28.60 KVASMALL APPLIANCEAPL0.00 KVA 0.00 KVA ( 100/35/25 %)PHASE B:58.64 KVALARGEST MOTORLGST0.00KVA 0.00 KVA (125%)PHASE C:55.96 KVAREMAINING MOTORSMTR0.00 KVA 0.00 KVA (100%)Total Connected Load =##### <= includes double lug loadsGEN PURPOSE RECPTREC55.90 KVA 32.95 KVA ( 50% > 10KVA)Load Checker Total =##### <= includes double lug loadsCOMPUTER RECPTCOMP0.00 KVA 0.00 KVA (100%)EQUIP/OTHERMISC1.50 KVA 1.50 KVA (100%)HEATINGHTG0.00 KVA 0.00 KVA (100%)NOTES:ELEVATORELEV0.00 KVA 0.00 KVA @100%1 NOTESKITCHEN EQPTKIT0.00 KVA 0.00 KVA @65%------------- -----------------TOTALS143.20 KVA 141.70 KVA172.24 AMPS 170.44 AMPSLOAD TYPE NOTES: "LGST" =LARGEST MOTOR SHOULD BE ENTERED MANUALLY AT END OF PROJECT"RES" = RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE LOAD TAKEN AT INDICATED DEMAND"MISC" = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED CIRCUIT AT 100%PANEL SCHEDULEPANEL:HLOCATION:SWITCHBOARDVOLTS:240 Y/120P1W:3AMP:300MLO MCB XAIC RATING:10,000MOUNT: SURFACE FLUSHTYPE: EXISTING XNEW STYLE:NEUTRAL:100%FED FROM:PANEL M VIA 50 KVA XFMR LOAD LOAD CKT P CIR P CIR P CKT LOAD LOADCIRCUIT DESCRIPTIONTYPE KVA BKR # H # BKR KVA TYPECIRCUIT DESCRIPTIONEXIST RECEPT - TENNIS FESTIVALREC 4.0050 21A22 504.00 RECEXIST RECEPT - SOFTBALL POLE C1 FESTIVAL-REC 4.00- -3B4- -4.00 REC-EXIST RECEPT - TENNIS FESTIVALREC 1.0020 15A61 201.00 RECEXIST RECEPT - SOFTBALL POLE C1 FESTIVALEXIST RECEPT - TENNIS FESTIVALREC 1.0020 17B82 508.00 RECEXIST RECEPT - SOFTBALL POLE C2 FESTIVALEXIST RECEPT - TENNIS FESTIVALREC 1.0020 19A10- -8.00 REC-SPARE 20 111B121 201.00 RECEXIST RECEPT - SOFTBALL POLE C2 FESTIVALEXIST RECEPT - SWBD FESTIVALREC 4.0050 213A141 200.36 RECEXIST RECPT - SOFTBALL-REC 4.00- -15B161 200.36 RECEXIST RECPT - TENNISEXIST RECEPT - SWBD FESTIVALREC 1.0020 117A181 200.18 RECEXIST RECPT - SWITCHBOARDEXIST RECEPT - SWBD FESTIVALREC 1.0020 119B201 201.00 RECEXIST RECPT - SOFTBALL POLE A1EXIST RECEPT - SWBD FESTIVALREC 1.0020 121A221 201.00 RECEXIST RECPT - SOFTBALL POLE A2SPARE 20 123B241 201.00 RECEXIST RECPT - SOFTBALL POLE B1EXIST IRRIGATION CONTROLLERSMISC 1.0020 125A261 201.00 RECEXIST RECPT - SOFTBALL POLE B2EXIST RECPT - POLE T7REC 1.0020 127B281 201.00 RECEXIST RECPT - SOFTBALL POLE C2EXIST RECPT - POLE T8REC 1.0020 129A301 200.50 MISCTIME CLOCKSPACE 31B32 SPACE 33A34 SPACE 35B36 SPACE 37A38 SPACE 39B40 SPACE 41A42 DEMAND CALCULATIONSLOAD SUMMARY: LOAD TYPE: CONNECTED CALCULATION DEMANDLIGHTING LTG 0.00 KVA 0.00 KVA (125%) CONNECTED PHASE LOADING RESIDENT LTG/RECPT RLTG 0.00 KVA 0.00 KVA ( 100/35/25 %)PHASE A:30.04 KVASMALL APPLIANCE APL 0.00 KVA 0.00 KVA ( 100/35/25 %)PHASE B:27.36 KVALARGEST MOTORLGST 0.00 KVA 0.00 KVA (125%)REMAINING MOTORS MTR 0.00 KVA 0.00 KVA (100%)Total Connected Load =57.40 <= includes double lug loadsGEN PURPOSE RECPT REC 55.90 KVA 32.95 KVA ( 50% > 10KVA)Load Checker Total =57.40 <= includes double lug loadsCOMPUTER RECPT COMP 0.00 KVA 0.00 KVA (100%)EQUIP/OTHER MISC 1.50 KVA 1.50 KVA (100%)HEATING HTG 0.00 KVA 0.00 KVA (100%)NOTES:ELEVATOR ELEV 0.00 KVA 0.00 KVA @100%1 NOTESKITCHEN EQPT KIT 0.00 KVA 0.00 KVA @65%------------- -----------------TOTALS57.40 KVA 34.45 KVA239.17 AMPS 143.54 AMPSLOAD TYPE NOTES: "COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT"RES" = RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE LOAD TAKEN AT INDICATED DEMAND"MISC" = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED CIRCUIT AT 100%SCHEDULES & DETAILSE1.1J:\2008 Projects\8097 - Big Liberty Park Imprv. - Lighting Upgrades\CADD\E11.dwg, 12/19/2008 10:44:32 AM, jbenson,12:12