Loading...
HomeMy WebLinkAboutSR_RainierDogERC_FINALDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Project Location Map SR_RainierDogERC_FINAL ENVIRONMENTAL REVIEW COMMITTEE REPORT ERC Meeting Date: June 3, 2024 Project File Number: PR24-000018 Project Name: Rainier Dog Resort and Spa Land Use File Number: LUA24-000093, SA-H, CU-H, ECF Project Manager: Andrew Van Gordon, Associate Planner Owner: KKDM LLC, P.O. Box 1121, Bellevue, WA 98009 Applicant/Contact: Owen Keeper, LMA Architects, 140 Lakeside Ave, Suite 310, Seattle, WA 98122 Project Location: 900 S Grady Way, Renton, WA 98057 Project Summary: The applicant is requesting a Hearing Examiner Conditional Use Permit, Hearing Examiner Site Plan Review and Environmental Review to establish a boarding and daycare facility for dogs. The project site is located at 900 S Grady Way (APN 1723059021). The site is zoned Center Downtown (CD) and is within Urban Design District A. Access is not proposed to be revised. Interior improvements, with no exterior work on the building, is proposed. The existing gravel area of the property is proposed to be enclosed with fencing and associated on-site landscaping between the fence and right-of-way. Hours of operation are proposed to be 7 a.m. to 6 p.m. with outdoor sessions between 10 a.m. and 4 p.m. The site is located within a High Seismic Hazard Area and the Wellhead Protection Area Downtown: Zone 2. Exist. Bldg. Area SF: 7,290 sq. ft. Proposed New Bldg. Area (footprint): Proposed New Bldg. Area (gross): N/A N/A Site Area: 38,180 sq. ft. Total Building Area GSF: 7,290 sq. ft. STAFF RECOMMENDATION: Staff Recommends that the Environmental Review Committee issue a Determination of Non-Significance - Mitigated (DNS-M). DocuSign Envelope ID: 53E579AF-21BE-47B4-9BC7-CC82CA1C6943 City of Renton Department of Community & Economic Development Rainier Dog Resort and Spa Staff Report to the Environmental Review Committee LUA24-000093, SA-H, CU-H, ECF Report of June 3, 2024 Page 2 of 9 SR_RainierDogERC_FINAL PART ONE: PROJECT DESCRIPTION / BACKGROUND The proposal is to establish a dog boarding and daycare facility on 900 S Grady Way. The existing on-site building is proposed to be incorporated into the project with no proposed exterior improvements (Exhibit 15). Interior improvements, to include demolition of some interior walls, construction of new interior walls and cosmetic enhancements such as wall and floor finishes (Exhibit 16). Reconfiguration of the existing two (2) restrooms for ADA compliance and improved accessibility is also proposed. Establishment of a fenced outdoor area with associated on-site vegetation is proposed for the dogs to play and go to the bathroom. Hours of operation are from 7:00 a.m. to 6:00 p.m. with outdoor group play sessions occurring between 10:00 a.m. and 4:00 p.m. A maximum of 50 dogs are proposed to be at the facility at any single time. PART TWO: ENVIRONMENTAL REVIEW In compliance with RCW 43.21C.240, the following environmental (SEPA) review addresses only those project impacts that are not adequately addressed under existing development standards and environmental regulations. A. Environmental Threshold Recommendation Based on analysis of probable impacts from the proposal, staff recommends that the Responsible Officials: Issue a DNS-M with a 14-day appeal period B. Mitigation Measures 1. The facility shall keep all windows closed at all times, except when needed to be open for unique circumstances such as cleaning or life and safety. Doors shall only be opened for entering and exiting the building and/or life and safety circumstances and shall not remain open beyond the immediate need. 2. The project shall comply with the recommendations of the Rainier Dog Resort and Spa Noise Study, prepared by Alan Burt, P.E. and Joshua Wah-Blumberg of SSA acoustics dated April 30, 2024. 3. The applicant’s acoustical consultant shall review the project’s construction and building permit plans to verify compliance with the acoustic report. The acoustical consultant shall submit a sealed letter stating they have reviewed the construction and building permit plans and in their opinion the plans and specifications meet the intent of the report. 4. The applicant shall provide an Inadvertent Discoveries Plan prepared by a qualified professional with the civil construction permit application if any ground disturbance cuts below asphalt and/or fill into native soils. The IDP shall be reviewed and approved by the Current Planning Project Manager prior to permit issuance. Notice shall be provided to Concerned Tribes to have a tribal monitor on-site if archaeological work or monitoring is performed. DocuSign Envelope ID: 53E579AF-21BE-47B4-9BC7-CC82CA1C6943 City of Renton Department of Community & Economic Development Rainier Dog Resort and Spa Staff Report to the Environmental Review Committee LUA24-000093, SA-H, CU-H, ECF Report of June 3, 2024 Page 3 of 9 SR_RainierDogERC_FINAL C. Exhibits Exhibit 1: Environmental Review Committee (ERC) Report Exhibit 2: Site Plan Exhibit 3: Project Narrative Exhibit 4: Rainier Dog Resort and Spa Property Line Noise Report prepared by Alan Burt, P.E. and Joshua Wah-Blumberg of SSA acoustics dated April 30, 2024 Exhibit 5: Transportation Concurrency Memo dated May 14, 2024 Exhibit 6: Duwamish Letter dated March 18, 2024 Exhibit 7: Staff Response to Duwamish Tribe Comments dated April 4, 2024 Exhibit 8: Public Comment from Ms. Judy received March 28, 2024 Exhibit 9: Staff Response to Ms. Judy Exhibit 10: Fence Detail Exhibit 11: SEPA Environmental Checklist prepared January 25, 2024 Exhibit 12: Hydrogeologic Assessment prepared by Scott S. Riegel of Earth Solutions NW, LLC, dated February 6, 2024 Exhibit 13: Rainier Dog Resort & Spa – Renton, WA Trip Generation Memo, prepared by Spenser Haynie of Transportation Engineering NorthWest (TENW) dated April 19, 2024 Exhibit 14: Previous Tenant Lease Exhibit 15: Exterior Elevations Exhibit 16: Floor Plans Exhibit 17: Advisory Notes D. Environmental Impacts The Proposal was circulated and reviewed by various City Departments and Divisions to determine whether the applicant has adequately identified and addressed environmental impacts anticipated to occur in conjunction with the proposed development. Staff reviewers have identified that the proposal is likely to have the following probable impacts: 1. Earth Impacts: The proposed improvements include interior renovation of the existing structure, removal of existing chain link fencing to be replaced with vinyl fencing with a 15-foot (15’) landscaping strip between the fencing and the property line along S Grady Way and Williams Ave S, and construction of a trash/recycling enclosure on an existing concrete pad on the north side of the existing building (Exhibit 3). Per the site plan (Exhibit 2) a new ADA accessible pathway will be constructed through an existing vegetated area in the southwest portion of the property connecting the existing on-site sidewalk with the sidewalk in the right-of-way of S Grady Way. Ground disturbance would be limited to removal/installation of fencing, removal of asphalt for new landscaping, planting of vegetation and construction of the ADA accessible pathway. Calculations for fill and grade were not provided, but Staff expects it to be minimal as the amount of ground disturbance would be minimal and any needed mitigation could be conditioned through the civil permit. Mitigation Measures: No further mitigation is recommended. Nexus: Not applicable. DocuSign Envelope ID: 53E579AF-21BE-47B4-9BC7-CC82CA1C6943 City of Renton Department of Community & Economic Development Rainier Dog Resort and Spa Staff Report to the Environmental Review Committee LUA24-000093, SA-H, CU-H, ECF Report of June 3, 2024 Page 4 of 9 SR_RainierDogERC_FINAL 2. Air Impacts: Temporary impacts to air from interior improvements, such as painting and drywall cutting, would occur. It is not expected that typical earthwork construction equipment and vehicle exhaust would occur as the type and intensity of exterior improvements is not proposed. Potential items such as exterior dust control, if it were to occur, can be mitigated through the use of temporary erosion control measures, watering or other measures to remediate impacts as needed. Per the SEPA Environmental Checklist, prepared on January 25, 2024 (Exhibit 10), the General Contractor and all subcontractors would keep the jobsite clean and comply with all the safety measures of each trade. Temporary emissions control can be conditioned through the civil construction permit. Mitigation Measures: No further mitigation is recommended. Nexus: Not applicable. 3. Water a. Ground Water Impacts: COR Maps identifies the project area as being within the Downtown Wellhead Protection Area Zone 2. The project does not include a prohibited facility as outlined in RMC 4-3-050, Critical Area Regulations. Per the Environmental Checklist, no groundwater would be withdrawn, and no waste material will be discharged into the ground. Due to the concern about animal waste in the wellhead protection area, the application provided a Hydrogeologic Assessment, prepared by Scott S. Riegel of Earth Solutions NW LLC, dated February 6, 2024 (Exhibit 11). Per the assessment, the site was visited in January 2024 to observe surface conditions. In the opinion of the assessment author, no adverse impacts to the local groundwater would occur. Based on the limited scope of the project and no significant change in use, no additional prohibitions or requirements would be required above those outlined in the Zone 2 code sections of RMC 4-3-050, Critical Area Regulations. It is expected that erosion control measures, if needed, can be conditioned through the civil construction permit. Mitigation Measures: No further mitigation is recommended. Nexus: Not applicable. 4. Vegetation Impacts: The site is made up of a large gravel area, existing building, surface parking and minimal landscaping in the southwest portion with some low hedges abutting the sidewalk along S Grady Way. A conceptual landscape plan was not provided; however, the proposed site plan does show the location of proposed plantings. They are concentrated along S Grady Way and Williams Ave S between the newly-proposed fence and the right-of-way. A portion between the existing building and Williams Ave S is also proposed. This would also include the proposed refuse/recycling enclosure area. Further, on- site vegetation is required along the shared property line with 536 Williams Ave S to meet zoning code requirements for the minimum side yard setback when a lot zoned CD is adjacent to a residentially zone lot; 536 Williams Ave S is zoned Residential – 14 (R-14). A 15-foot (15’) wide partially sight- obscuring landscaped strip or a five-foot (5’) wide fully sight-obscuring landscaped strip and a solid six- foot (6’) high barrier along the common boundary is required. Review of the fence and associated vegetation would occur during the civil construction permit by the Planning Project Manager; installation would be required prior to final inspection. The City received a letter from the Duwamish Tribe (Exhibit 6) strongly recommending that only native vegetation be used to enhance native avian life and native pollinators as well as to mitigate seasonal urban flooding. Native vegetation and location of vegetation can be required through the Site Plan Review application. DocuSign Envelope ID: 53E579AF-21BE-47B4-9BC7-CC82CA1C6943 City of Renton Department of Community & Economic Development Rainier Dog Resort and Spa Staff Report to the Environmental Review Committee LUA24-000093, SA-H, CU-H, ECF Report of June 3, 2024 Page 5 of 9 SR_RainierDogERC_FINAL Mitigation Measures: No further mitigation is recommended. Nexus: Not applicable. 5. Environmental Health a. Noise Impacts: City staff received public comment (Exhibit 8) with concerns about potential noise issues impacting the surrounding neighborhood. In response, staff requested the applicant complete a noise study by a qualified professional. In response to staff’s request, the applicant provided the Rainier Dog Resort and Spa Property Line Noise Report prepared by Alan Burt, P.E. and Joshua Wah-Blumberg of SSA acoustics dated April 30, 2024 (Exhibit 4). SSA acoustics measured the existing ambient noise level on site hourly over a 24-hour period from 12:00 a.m. to 12:00 a.m. on April 9, 2024 at one (1) location northeast of the building at the shared property line with 541 Wells Ave S (APN 1723059054). Short-term measurements were conducted on April 11, 2024 at four (4) on-site locations. It was found that the hourly decibels ranged from 58 to 65 decibels during the day and 55 to 63 decibels during the night. The short-term measurements found the ambient noise level decibels ranging from 57 to 67 decibels with the loudest location being between the existing building and S Grady Way (67 decibels) to the south and the quietest being between the existing building and Williams Ave S to the north. The building itself is metal frame construction with insulation, structural sheeting, metal siding with gypsum wallboard (GWB) on the interior of the walls. The GWB in the kennel room, holding area, reception and luxury suites extends all the way to the ceiling. The BWG on the inside of the wall of the playrooms stops at approximately 12 feet (12’). There is a glass, exterior double door to the reception area on the southwest side of the building, a metal exterior double door and metal roll-up door to the second playroom on the northwest side of the building. The exterior door to the kennel room has a full set of acoustical seals that prevent noise from passing through gaps at the perimeter of the door. Noise reduction from existing improvements would reduce decibel levels from 25 to 42 decibels. The least reduced area is the second playroom façade with the most being the holding area façade. Based on predicted noise levels of dogs, the noise level of one (1) dog barking is 89 decibels up to 104 decibels. During the daytime, up to 20 dogs would be allowed in the first playroom with up to five (5) dogs in the second playroom. Up to 18 dogs would be kept in the holding area. All dogs would be required to pass a temperament evaluation to be allowed into the outdoor yard area for play; if a dog starts barking it would be returned to the kennel. All dogs would be kept in the kennels or suites unless they are in the indoor playrooms or in the outdoor play and bathroom areas. During the nighttime up to 28 dogs would be kept inside the kennel room with up to six (6) dogs in the luxury suites. If the maximum number of dogs barking in each room occurs the average noise level would range from 96 decibels to 104 decibels with the maximum being 111 decibels to 119 decibels. The report identifies that Washington Administrative Code (WAC) 173-60 identifies residential properties as Class A EDNA and commercial properties as Class B EDNA. Under WAC 173 -60, Maximum Permissible Environmental Noise Levels, noise from a Class B EDNA property is limited as: Class A EDNA Receiver: Noise is limited to 57 decibels during daytime house. During nighttime hours, between the hours of 10:00 p.m. and 7:00 a.m. the maximum permissible sound level is 47 decibels. Class B EDNA Receiver: Noise is limited to 60 decibels 24 hours a day. DocuSign Envelope ID: 53E579AF-21BE-47B4-9BC7-CC82CA1C6943 City of Renton Department of Community & Economic Development Rainier Dog Resort and Spa Staff Report to the Environmental Review Committee LUA24-000093, SA-H, CU-H, ECF Report of June 3, 2024 Page 6 of 9 SR_RainierDogERC_FINAL Further, during any hour of the day or night the applicable noise limitations may be exceeded for any receiving property by no more than: a) Five (5) decibels for a total of 15 minutes in any one (1) hour period; or b) 10 decibels for a total of five (5) minutes in any one (1) hour period; or c) 15 decibels for a total of one and a half (1.5) minutes in any one (1) hour period. The report calculated predictive average and maximum noise levels at neighboring receiving properties during the daytime and nighttime for interior barking levels. Properties generally to the north are commercial with properties generally to the south commercial. The report found that average interior barking levels would meet limitations and would be similar or less than existing ambient noise levels. It also found that the predicted maximum interior barking levels would meet limitations on allowed temporary decibel levels. No further interior mitigation is recommended. However, the analysis was completed with all doors and windows closed. While it isn’t realistic to expect all doors and windows to remain closed at all times, if they were to be left open it is expected that noise levels would increase. As such, staff recommends as a mitigation measure that the facility keep all windows closed at all times, except when needed to be open for unique circumstances such as cleaning or life and safety. Doors shall only be opened for entering and exiting the building and/or life and safety circumstances and shall not remain open beyond the immediate need. With regards to exterior noise levels, up to 10 total dogs would be outside at any time. Outdoor play is expected to be generally quiet, and if a dog barks, it would be immediately returned to its kennel in the building. For the purposes of the study, the report indicates it assumes that noise from a dog barking in the yard would be instantaneous and only last a short duration, so the maximum noise levels are compared to the 75 decibel one and a half (1.5) minute daytime code limits at the receiving properties. It was found that as currently developed exterior noise levels would exceed allowed levels. Proposed noise mitigation includes: • Limiting the yard area available to the dogs and ensure that dogs are not able to be within 15 feet (15’) of the north and northeast properties (536 Williams Ave S and 541 Wells Ave S). • Construct noise barriers on the north, west, east and south sides of the yard. The top of the noise barriers that run along the north side of yards should be at least eight feet (8’) above grade. The remaining noise barriers should be at least six feet (6’) above grade. • Construct the noise barriers with a solid material that has a surface mass of at least four (4.0) pounds per square foot. The following are common barrier materials that meet this requirement: o Two (2) layers of three fourths inch (3/4”) exterior grade plywood. o Two (2) layers of 16-gauge sheet metal. o Two (2) layers of HardiePanel. • Install acoustical panels on all available surfaces along the dog-facing side of the barriers. Panels need to have a minimum NRC of 0.80. Open metal grid materials, such as chicken wire, may be added to the face of the sound absorbing material to prevent dogs from chewing on it. Recommended products for this application are: o Two inch (2”) Polysorb. o Two inch (2”) thick FSorb. DocuSign Envelope ID: 53E579AF-21BE-47B4-9BC7-CC82CA1C6943 City of Renton Department of Community & Economic Development Rainier Dog Resort and Spa Staff Report to the Environmental Review Committee LUA24-000093, SA-H, CU-H, ECF Report of June 3, 2024 Page 7 of 9 SR_RainierDogERC_FINAL As such, staff recommends as a mitigation measure that the project comply with the recommendations of the Rainier Dog Resort and Spa Noise Study, prepared by Alan Burt, P.E. and Joshua Wah-Blumberg of SSA acoustics dated April 30, 2024 and any future addenda. Additionally, staff recommends the applicant’s acoustical consultant review the project’s construction and building permit plans to verify compliance with the acoustic report(s). The acoustical consultant shall submit a sealed letter stating they have reviewed the construction and building permit plans and in their opinion the plans and specifications meet the intent of the report(s). Mitigation Measures: 1. The facility shall keep all windows closed at all times, except when needed to be open for unique circumstances such as cleaning or life and safety. Doors shall only be opened for entering and exiting the building and/or life and safety circumstances and shall not remain open beyond the immediate need. 2. The project shall comply with the recommendations of the Rainier Dog Resort and Spa Noise Study, prepared by Alan Burt, P.E. and Joshua Wah-Blumberg of SSA acoustics, dated April 30, 2024 and any future addenda. 3. The applicant’s acoustical consultant shall review the project’s construction and building permit plans to verify compliance with the acoustic report(s). The acoustical consultant shall submit a sealed letter stating they have reviewed the construction and building permit plans and in their opinion the plans and specifications meet the intent of the report(s). Nexus: State Environmental Policy Act (SEPA) Environmental Review; RMC 4-9-030, Conditional Use Permits; RMC 4-9-200, Master Plan and Site Plan Review. 6. Aesthetics Impacts: The applicant is proposing an eight-foot (8’) tall fence (Exhibit 9). The fence would enclose an existing exterior mostly gravel area to be used for exterior play and bathroom areas. Fencing with sound paneling is proposed along the northern boundaries of the enclosure with the remainder being vinyl fencing. Fencing in this northern area follows the general location of existing chain link fencing including a small portion which appears to be off site; this can be conditioned through the land use permitting process to be placed on site. Other portions of the fence would be parallel with the right- of-way of S Grady Way and Williams Ave S. In these areas a 15-foot (15’) wide on-site landscaping strip between the fence and the right-of-way is proposed. Additional, vegetation is proposed between the existing building and Williams Ave S. The type of proposed vegetation is unknown; however, type of vegetation and density can be conditioned through the site plan review. Per the project narrative, no exterior work is proposed on the existing building (Exhibit 3). Building improvements would be limited to interior work. A pedestrian connection would be made between the building entrance and the sidewalk for ADA accessibility. The property is within Urban Design District ‘A’. Review of applicable standards, as well as the overall site design, would occur during the site plan review application. It is anticipated that the City’s Urban Design Standards and site plan review criteria would adequately mitigate aesthetic impacts of the proposal. Mitigation Measures: No further mitigation is recommended. Nexus: Not applicable. 7. Historic and Cultural Preservation Impacts: The City received public comment from the Duwamish Tribe that the project is located within a mile of at least eight (8) Duwamish place names and near several known archaeological sites (Exhibit 6). The Washington State Department of Archaeology and Historic Preservation (DAHP) WISAARD DocuSign Envelope ID: 53E579AF-21BE-47B4-9BC7-CC82CA1C6943 City of Renton Department of Community & Economic Development Rainier Dog Resort and Spa Staff Report to the Environmental Review Committee LUA24-000093, SA-H, CU-H, ECF Report of June 3, 2024 Page 8 of 9 SR_RainierDogERC_FINAL predictive model indicates that a survey is highly advised with a very high risk for encountering cultural resources. As such, based on the information provided and understanding of the project, the Duwamish Tribe recommends an inadvertent discovery plan (IDP) if any ground disturbance cuts below asphalt/fill into native soils. In the event that any archaeological work or monitoring is performed, the Tribe would like notification and to have the opportunity to be present if or when an archeologist is on site. As such, staff recommends as a mitigation measure, that the applicant provide an Inadvertent Discoveries Plan prepared by a qualified professional with the civil construction permit application if any ground disturbance cuts below asphalt and/or fill into native soils. The IDP shall be reviewed and approved by the Current Planning Project Manager prior to permit issuance. Notice shall be provided to Concerned Tribes to have a tribal monitor on-site if archaeological work or monitoring is performed. Mitigation Measures: 1. The applicant shall provide an Inadvertent Discoveries Plan prepared by a qualified professional with the civil construction permit application if any ground disturbance cuts below asphalt and/or fill into native soils. The IDP shall be reviewed and approved by the Current Planning Project Manager prior to permit issuance. Notice shall be provided to Concerned Tribes to have a tribal monitor on-site if archaeological work or monitoring is performed. Nexus: City of Renton Comprehensive Goals and Policies, L-AA, L-45 and L-46; Chapter 27.53 RCW, Archaeological Sites and Resources; Chapter 27.44 RCW, Indian Graves and Records; Chapter 197-11 WAC, SEPA Rules. 8. Transportation Impacts: The proposed project fronts upon S Grady Way and Williams Ave S culminating in the intersection of the two (2) streets at the southwest portion of the project site. A Traffic Scoping Memorandum authored by Spenser Haynie of Transportation Engineering NorthWest (TENW), dated April 19, 2024 (Exhibit 12), was provided with the application. The analysis determined vehicular traffic generated from the proposed development did not exceed 20 new vehicle trips per hour in either the a.m. or the p.m. peak period with credit given due to the site being occupied by a business within the last three (3) years prior to the application. Based on the calculations provided, the proposed development would average a decrease of 133 new daily vehicle trips for dog daycare/boarding facility versus Health/Fitness Club. Weekday peak hour a.m. trips would generate an increase of 13 new vehicle trips, with six (6) vehicles leaving and seven (7) vehicles entering the site. Weekday peak hour p.m. trips would generate a decrease of two (2) new vehicle trips, with a decrease of three (3) vehicles entering and one (1) vehicle exiting the site. Per RMC 4-1-090G.4, Vacant Structures or Buildings, “When an existing structure or building or portion thereof has been vacant for a period of three (3) years or more, the impact fee shall be the applicable impact fee for the land use of the new category; there shall not be a deduction of the impact fee that was or was previously paid for the land use category of the prior use.” The impact fee will be reviewed at time of building permit application and due to vacancy limits may not be subject to receiving credit as the previous use was abandoned September 2021 (Exhibit 13). No frontage improvements are required as the project as proposed does not meet the financial threshold. The proposal has passed the City’s Traffic Concurrency Test (Exhibit 5) per RMC 4-6-070D, which based upon a test of the citywide Transportation Plan, consideration of growth levels included in the LOS-test Transportation Plan, and future payment of appropriate Transportation Impact Fees. Mitigation Measures: No further mitigation is recommended. Nexus: Not applicable. DocuSign Envelope ID: 53E579AF-21BE-47B4-9BC7-CC82CA1C6943 City of Renton Department of Community & Economic Development Rainier Dog Resort and Spa Staff Report to the Environmental Review Committee LUA24-000093, SA-H, CU-H, ECF Report of June 3, 2024 Page 9 of 9 SR_RainierDogERC_FINAL 9. Fire & Police Impacts: Police and Fire Prevention staff reviewed the project but did not provide comments. As such, it is expected that sufficient resources exist to furnish services to the proposed development provided the applicant constructs Code required improvements and pays associated impact fees. Mitigation Measures: No further mitigation recommended. Nexus: Not applicable. E. Comments of Reviewing Departments The proposal has been circulated to City Department and Division Reviewers. Where applicable, their comments have been incorporated into the text of this report and/or “Advisory Notes to Applicant.” ✓ Copies of all Review Comments are contained in the Official File and may be attached to this report. The Environmental Determination decision will become final if the decision is not appealed within the 14 -day appeal period (RCW 43.21.C.075(3); WAC 197-11-680). Environmental Determination Appeal Process: Appeals of the environmental determination must be filed in writing on or before 5:00 p.m. on June 17, 2024. Appeals must be submitted electronically to the City Clerk at cityclerk@rentonwa.gov or delivered to City Hall 1st floor Lobby Hub Monday through Friday. The appeal fee, normally due at the time an appeal is submitted, will be collected at a future date if your appeal is submitted electronically. The appeal submitted in person may be paid on the first floor in our Finance Department. Appeals to the Hearing Examiner are governed by RMC 4-8-110 and additional information regarding the appeal process may be obtained from the City Clerk’s Office, cityclerk@rentonwa.gov. DocuSign Envelope ID: 53E579AF-21BE-47B4-9BC7-CC82CA1C6943 CITY OF RENTON DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT STAFF REPORT TO THE ENVIRONMENTAL REVIEW COMMITTEE EXHIBITS Project Name: Rainier Dog Resort and Spa Land Use File Number: LUA24-000093, SA-H, CU-H, ECF Date of Meeting June 3, 2024 Staff Contact Andrew Van Gordon Associate Planner Project Contact/Applicant Owen Keeper LMA Architects 140 Lakeside Ave, Suite 310, Seattle, WA 98122 Project Location 900 S Grady Way, Renton, WA 98057 The following exhibits are included with the ERC Report: Exhibit 1: Environmental Review Committee (ERC) Report Exhibit 2: Site Plan Exhibit 3: Project Narrative Exhibit 4: Rainier Dog Resort and Spa Property Line Noise Report prepared by Alan Burt, P.E. and Joshua Wah-Blumberg of SSA acoustics dated April 30, 2024 Exhibit 5: Transportation Concurrency Memo dated May 14, 2024 Exhibit 6: Duwamish Letter dated March 18, 2024 Exhibit 7: Staff Response to Duwamish Tribe Comments dated April 4, 2024 Exhibit 8: Public Comment from Ms. Judy received March 28, 2024 Exhibit 9: Staff Response to Ms. Judy Exhibit 10: Fence Detail Exhibit 11: SEPA Environmental Checklist prepared January 25, 2024 Exhibit 12: Hydrogeologic Assessment prepared by Scott S. Riegel of Earth Solutions NW, LLC, dated February 6, 2024 Exhibit 13: Rainier Dog Resort & Spa – Renton, WA Trip Generation Memo, prepared by Spenser Haynie of Transportation Engineering NorthWest (TENW) dated April 19, 2024 Exhibit 14: Previous Tenant Lease Exhibit 15: Exterior Elevations Exhibit 16: Floor Plans Exhibit 17: Advisory Notes DocuSign Envelope ID: 53E579AF-21BE-47B4-9BC7-CC82CA1C6943