Loading...
HomeMy WebLinkAboutBUILDING PERMIT REVISIONBUILDING PERMIT REVISION        5/17/2024    Job Address  2123 Shattuck Place South, Renton, WA 98055  Project Name  Vu Residence  Contact information Tracy Brink, 206‐779‐6149, tlb.arch@gmail.com    Corrections/Resubmittal  Andrew Van Gordon, Planning Department      Comment 1  Existing Elevations, Sheet A4    Front porch needs to be at least 12 inches above grade.  Show height of porch above grade. RMC4‐2‐115E3, Residential Design.    Front porch is three risers (18”) above grade.    Comment 2  Existing Elevations, Sheet A4    Windows and doors shall constitute 25 percent (25%) of all facades facing street frontages. Provide  window area and gross facade area calculations of all facades facing the street. RMC4‐2‐115E3,  Windows and Doors.    Area calculations are not needed, by visual inspection the east and west elevations clearly exceed this  requirement, and the south elevation clearly does not meet this requirement. A modification is  requested for the south elevation.    Comment 3  Existing Elevations, Sheet A4    If one siding material is used on any side of the dwelling that is two (2) stories or greater in height, a  horizontal band that measures at least eight inches (8") is required between the first and second story.  Additionally, one (1) of the following is required.  1. Three and one‐half inch (3.5") minimum trim surrounds all windows and details all doors, or  2. A combination of shutters and three and one‐half inches (3.5") minimum trim details all windows, and  three and one‐half inches (3.5") minimum trim details all doors.  No band between the first and second floor is shown. Trim measurements need to be shown.    The south elevation incorporates two separate siding materials; horizontal lap siding above, and shingle  siding below, separated by a continuous trim band. These two siding materials are also differentiated by  two separate colors. All street facing windows and doors are trimmed with a minimum 1x4 at sill, jambs,  and head. A band between the first and second floor is not required.    Comment 4  Site Plan, Sheet A1    Version 2 comments included an incorrect code reference. Version 1 comments, referenced in Version 2,  included the correct code reference on the site plan and was not addressed.    Your comment regarding the existing garage is not applicable per RMC‐4‐2‐115B1. The standards of Site  Design subsection are required to be addressed at the time of subdivision application. Garage standards  are part of Site Design, and this is not a subdivision application.    Comment 5  Site Plan, Sheet A1    A modification is required to deviate from applicable RMC 4‐2‐115 Standards. A modification request is  required to be reviewed and approved prior to Planning's approval of the building permit; each  modification request has a fee of $290.00. Contact planning through email at  avangordon@rentonwa.gov if there are questions.    A modification is requested for deviation from minimum glazing area at a façade facing the street.  A Master Application form and a Modification of Residential Design Regulations form will be submitted  along with a copy of the plan set sheets A0 Site Plan and A4 Building Elevations.