Loading...
HomeMy WebLinkAboutMFP24002925.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP24002925 IVR Number: 24002925 Permit Information Permit Name: N.973435 Address/Location:06/07/2024Application Date:3779200090Parcel Number: 550 MONSTER RD SW Permit Type:06/12/2024Issue Date:Franchise Permit Work Class:06/12/2025Expiration Date:Major Utility Job Number: N.973435Franchise Type:Telephone Description: MH 113, MH 110, MH 116, MH 117, MH 120, MH 169, MH 661. MH 351. MH 714. REPLACE 17X30 HH PLACE THROUGH NEW HH, PLACE NEW HH. TRENCH AND PLACE NEW HH. Contacts Name Address PhoneTypeBilling Nathan Macleod Lumen 7850 S Trafton St, Bldg B Tacoma, WA 98409 C: (253) 583-6283ApplicantX Ron Desmet Fibe Solutions 604 W Meeker St., Suite 103 KENT, WA 98032 C: (206) 571-2230Applicant Prime Electric Inc 3460 161ST Ave SE Bellevue, WA 98008 Applicant Kim Parker QWest Corporation 931 14th St, Suite 1000A Denver, CO 80202 B: (303) 992-0752Contact Cheyenne Classen North Sky Communications 2112 97th Ave E Tacoma, WA 98444 Contact Michael Smith North Sky Communications 21320 84th Ave S Kent, WA 98032 C: (206) 305-5881Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner QWest/Century Link - Billing 23315 66th Ave S Kent, WA 98032 Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 10/27/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 10/27/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐ Electronic Copy of the TCP Application ☐ Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall:  Include map(s) showing the location of the project and work area.  Be legible lettering and clear, contrasting, symbols of viewing or printing.  Must indicate street names, and north arrow and scale.  Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering Northsky Communications 7/1/2024 8am 5pm7/8/2024 MFP24002925 / N.973435.pdf Mike Smith MFP24002925 MH 113, MH 110, MH 116, MH 117, MH 120, MH 169, MH 661. MH 351. MH 714. REPLACE 17X30 HH PLACE THROUGH NEW HH, PLACE NEW HH. TRENCH AND PLACE NEW HH. 16701 SE McGillivrary Blvd Vancouver WA 98683-3462 425-615-7121 550 MONSTER ROAD SW Scott Warlick CED 6/12/2024 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING:  Must have approved Traffic Control Plan (TCP) prior to commencing the work.  Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians.  WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way.  Comply with all traffic regulations of the City of Renton and the State of Washington.  Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices.  Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.  Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work.  Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions.  Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes.  Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees.  The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim.  In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same.  Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel.  All permit conditions shall be met. NOTES:  Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.  Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT.  Approved Temporary Traffic Control Plan must be at the work site during work hours.  Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone.  Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours.  Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 10/27/2021  In the case of Temporary No Parking Zones, all the following apply in addition to previous:  Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage.  Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time.  The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site.  Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) Merilyn Luong 6/12/2024 OAKESDALE AVE SW @ SW 7TH STWORK @ MH-669RIGHT-LANE CLOSURE TRAFFIC CONTROL PLANJOB # N. 973435. C. 46PERMIT #Comments: WORK @ MH-669 LOCATED OFF ROADWAY.RIGHT-LANE CLOSURE NORTHBOUNDOAKESDALE AVE SW. ARROW BOARD USED.DRIVEWAYS REMAIN OPEN/ACCESSIBLE.SIDEWALKS REMAIN OPEN/ACCESSIBLE.SPOTTER WILL ASSIST AT WORK AREA.ISLANDSPOTTERSOAKESDALE AVE SWOAKESDALE AVE SWSW 7TH ST ARROWBOARD DRIVEWAYDRIVEWAYWORK @ MH-669 NX350' +-ROADWORKAHEADW2 0 - 1 LEGENDARROW BOARD CONESSSPOTTERWORK AREAWORK TRUCK SIDEWALK 111111111111 1111 Date:6/4/2024 Author:Jeffrey D. Hubbard, Traffic Control Supervisor Project:________________CERT:WA TCS # ES2000151 (Exp: 4/2027)DESIGNED FOR:LUMEN LOCATION:RENTON, WAComments: General Requirements1. All signs and spacing to conform to the MUTCD and CITY OF RENTON Requirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 36" x 36" B/O unless otherwise specified.4. Alert affected local residents and businesses.5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be determined by CITY OF RENTON. NOT TO SCALEComments: MERGING TAPER LENGTHTAPER ("L") LANE WIDTH L MPH 10' 11' 12'SHIFTING 20 70 75 80TAPER 25 105 115 1651/2 L 30 150 165 180 35 205 225 245SHOULDER 40 270 295 320TAPER 45 450 495 5401/3 L 50 500 550 600 TCP PROPOSAL: NOT VALID W/O R-O-W JURISDICTION APPROVAL STAMPUNLAWFUL FOR ANYONE (OTHER THAN R-O-W APPROVAL JURISDICTION)TO ALTER W/O CONSENT FROM AUTHOR (JHUBBARD.TCP@GMAIL.COM) DESIGNED FOR: LUMENJeffrey D. HubbardTraffic Control SupervisorWA TCS # ES2 000151Draw Date: 6/4/2024Phone 253-737-5198jhubbard.tcp@gmail.com_______________________SPEEDLIMIT35 WORK AREA10' X ~50'SPEEDLIMIT35 X350' +-X350' +-X350' +-ROADWORKAHEADW20-1W4-2PLACE IN ADVANCE OF WORK ZONERIGHT LANECLOSEDAHEADW20-5L~225'+- www.invarion.comMFP24002925 NACHES AVE SW @ SW 7TH STWORK @ MH-660LANE-SHIFT TRAFFIC CONTROL PLANJOB # N. 973435. C. 46PERMIT # Comments: WORK @ MH-660 LOCATED OFF ROADWAY.LANE-SHIFT NORTHBOUND NACHES AVE SW.DRIVEWAYS REMAIN OPEN/ACCESSIBLE.SIDEWALKS REMAIN OPEN/ACCESSIBLE.SPOTTER WILL ASSIST AT WORK AREA.NLEGENDCONESSPOTTERSSPOTTERWORK AREAWORK TRUCK Date:6/4/2024 Author:Jeffrey D. Hubbard, Traffic Control Supervisor Project:________________CERT:WA TCS # ES2000151 (Exp: 4/2027)DESIGNED FOR:LUMEN LOCATION:RENTON, WAComments: General Requirements1. All signs and spacing to conform to the MUTCD and CITY OF RENTON Requirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 36" x 36" B/O unless otherwise specified.4. Alert affected local residents and businesses.5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be determined by CITY OF RENTON. NOT TO SCALEComments: MERGING TAPER LENGTHTAPER ("L") LANE WIDTH L MPH 10' 11' 12'SHIFTING 20 70 75 80TAPER 25 105 115 1651/2 L 30 150 165 180 35 205 225 245SHOULDER 40 270 295 320TAPER 45 450 495 5401/3 L 50 500 550 600 TCP PROPOSAL: NOT VALID W/O R-O-W JURISDICTION APPROVAL STAMPUNLAWFUL FOR ANYONE (OTHER THAN R-O-W APPROVAL JURISDICTION)TO ALTER W/O CONSENT FROM AUTHOR (JHUBBARD.TCP@GMAIL.COM) DESIGNED FOR: LUMENJeffrey D. HubbardTraffic Control SupervisorWA TCS # ES2 000151Draw Date: 6/4/2024Phone 253-737-5198jhubbard.tcp@gmail.com_______________________20202020X200' +-LANESHIFTAHEADW5-5W1-4X200' +-ROADWORKAHEADW20-1X350' +-ROADWORKAHEADW20-1X350' +-SW 7TH STSW 7TH STNACHES AVE SW ISLANDISLANDSPOTTERSSIDEWALKSIDEWALKWORK@ MH-660 WORK AREA8' X ~50'NACHES AVE SW11' MINISLAND 1/2 L~60'+- www.invarion.comMFP24002925 NACHES AVE SW @ SW 7TH STWORK @ MH-661SHOULDER WORK TRAFFIC CONTROL PLANJOB # N. 973435. C. 46PERMIT #Comments: WORK @ MH-661 LOCATED OFF ROADWAY.SHOULDER WORK. NO TRAFFIC IMPACT.DRIVEWAYS REMAIN OPEN/ACCESSIBLE.SIDEWALKS REMAIN OPEN/ACCESSIBLE.SPOTTER WILL ASSIST AT WORK AREA.NLEGENDCONESSPOTTERSSPOTTERWORK AREA WORK TRUCK Date:6/4/2024 Author:Jeffrey D. Hubbard, Traffic Control Supervisor Project:________________CERT:WA TCS # ES2000151 (Exp: 4/2027)DESIGNED FOR:LUMEN LOCATION:RENTON, WAComments: General Requirements1. All signs and spacing to conform to the MUTCD and CITY OF RENTON Requirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 36" x 36" B/O unless otherwise specified.4. Alert affected local residents and businesses.5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be determined by CITY OF RENTON. NOT TO SCALEComments: MERGING TAPER LENGTHTAPER ("L") LANE WIDTH L MPH 10' 11' 12'SHIFTING 20 70 75 80TAPER 25 105 115 1651/2 L 30 150 165 180 35 205 225 245SHOULDER 40 270 295 320TAPER 45 450 495 5401/3 L 50 500 550 600 TCP PROPOSAL: NOT VALID W/O R-O-W JURISDICTION APPROVAL STAMPUNLAWFUL FOR ANYONE (OTHER THAN R-O-W APPROVAL JURISDICTION)TO ALTER W/O CONSENT FROM AUTHOR (JHUBBARD.TCP@GMAIL.COM) DESIGNED FOR: LUMENJeffrey D. HubbardTraffic Control SupervisorWA TCS # ES2 000151Draw Date: 6/4/2024Phone 253-737-5198jhubbard.tcp@gmail.com_______________________NACHES AVE SW SPOTTERS SIDEWALKSIDEWALKWORK@ MH-661 WORK AREA8' X ~50'NACHES AVE SW34X200' +-ROADWORKAHEADW20-1SHOULDERWORKW21-5X200' +-X200' +-ROADWORKAHEADW20-134NOFROMTOTOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555PARKINGNOFROMTOTOW AWAY AREAPHONE 68 4-5 44 4 YOU R COM PAN Y NAM E 5 55 -5 55 5PARKINGNOFROMTOTOW AWAY AREAPHONE 684-5444YOUR COMPANY NAME 555-5555PARKINGNOFROMTOTOW AWAY AREAPHONE 68 4-5 44 4 YOU R COM PAN Y NAM E 5 55 -5 55 5PARKING SW 7TH STDRIVEWAY www.invarion.comMFP24002925 SW 7TH ST LIND AVE SWSENECA AVE SWTHOMAS AVE SWSW 7TH ST TRAFFIC CONTROL PLANJOB # N.973435.C.46PERMIT # Date:6/4/2024 Author:JORGIA DURR Project:N.973435.C.46DESIGNED FOR LUMEN:(DO NOT ALTER)Comments: General Requirements1. All signs and spacing to conform to the MUTCD and City of RENTON requirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified.4. Alert affected local residents and businesses.5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be determined by City, County, and/or WSDOT LegendCONESSSPOTTERWORK TRUCKMANHOLEWork AreaNOT TO SCALE N 6/4/2024Jorgia DurrTCS # ES2 000149Phone 253-737-5198jd.durr@outlook.com_______________________Jorgia Durr MERGING DEVICES DEVICESSHIFTING12 FEETL1/2 L 770 6 6810161519 345599999 711 11 181820 406075225250275 115 115165295495550605660715 85150305330370385 MERGING DEVICES DEVICESSHIFTING11 FEETL1/2 LMERGINGDEVICESDEVICESSHIFTING10 FEETL1/2 L 6666 33344 77 2025303540455055606570 2535507015090170185200220200 DEVICESLENGTHMPHSHOULDER TAPERSASSUMES 10' SHOULDER2025303540455055606570 MPHLANEWIDTH 70065060055050045027020515010570 668810161614151719 355575105135225250275300325350 68810 3455999 660600 80125180245320540720780840 61016191997 182221 12 4065 300330 90125160270360390420 1010 34556991112 SHOULDER TAPERSHOULDER WIDTH x SPEED / 3(EXTRACTED FROM APPENDIX 1-1, OF THE WORK ZONE TRAFFIC CONTROL GUIDELINES- M54-44, 2012) ONE LANE TWO WAY TAPER 50' MIN / 100' MAXTAPER/ CHANNELIZING DEVICE TABLEMERGING, SHIFTING, AND SHOULDER TAPER LENGTHS AND NUMBER OF CHANNELIZATION DEVICES USED(WASHINGTON STATE DEPARTMENT OF TRASPORTATION)(ALL MINIMUMS) RURAL HIGHWAYSRURAL ROADSRURAL ROADS & URBAN ARTERIALSRURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTSURBAN STREETS(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. 50 / 65 MPH45 / 55 MPH35 / 40 MPH25 / 30 MPH25 MPH OR LESS 800' +/-500' +/-200' +/- (2)100' +/- (2)350' +/-SIGN SPACING = X (1) CHANNELIZING DEVICE SPACING (FEET)MPH TAPER TANGENT50/7035/4525/30 40'40'30'20'80'60'ONE LANE TWO WAY TTC ZONE TAPER 20'TANGENT 40' SPACING AT ALL SPEEDS UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:JORGIA DURR, TCS # ES2 000149, jd.durr@outlook.com LXXX X X X X MH 110 WORK AREA+/- 11' X 480' DETOUREXITCLOSED ROADWORKAHEAD RIGHT LANECLOSEDAHEADROADWORKAHEAD ROADWORKAHEAD ROADWORKAHEAD ROADWORKAHEAD Comments: THIS IS TO ACCESS MH 110THIS IS A RIGHT LANE CLOSUREMH LID WILL BE REPLACED AT WORK AREA FOR PEDESTRIAN ACCESS AS NECESSARYDRIVEWAYS CLOSED AT WORK AREATRAFFIC DETOURED TO OTHER EXIT AT WORK AREAREFER TO CHARTS FOR SIGN SPACING, DEVICE SPACING AND TAPER LENGTHSSW 7TH ST @ LIND AVE SWMH 110 ACCESSRIGHT LANE CLOSURE S www.invarion.comMFP24002925 NSW 7TH STOAKESDALE AVE SWSPEED LIMIT35 SW 7TH STTRAFFIC CONTROL PLANJOB # N.973435.C.46PERMIT # Date:6/4/2024 Author:JORGIA DURR Project:N.973435.C.46DESIGNED FOR LUMEN:(DO NOT ALTER)Comments: General Requirements1. All signs and spacing to conform to the MUTCD and City of RENTON requirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified.4. Alert affected local residents and businesses.5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be determined by City, County, and/or WSDOT LegendCONESMANHOLEWork AreaWORK TRUCKSSPOTTER NOT TO SCALE6/4/2024Jorgia DurrTCS # ES2 000149Phone 253-737-5198jd.durr@outlook.com_______________________Jorgia Durr MERGING DEVICES DEVICESSHIFTING12 FEETL1/2 L 770 6 6810161519 345599999 711 11 181820 406075225250275 115 115165295495550605660715 85150305330370385 MERGING DEVICES DEVICESSHIFTING11 FEETL1/2 LMERGINGDEVICESDEVICESSHIFTING10 FEETL1/2 L 6666 33344 77 2025303540455055606570 2535507015090170185200220200 DEVICESLENGTHMPHSHOULDER TAPERSASSUMES 10' SHOULDER2025303540455055606570 MPHLANEWIDTH 70065060055050045027020515010570 668810161614151719 355575105135225250275300325350 68810 3455999 660600 80125180245320540720780840 61016191997 182221 12 4065 300330 90125160270360390420 1010 34556991112 SHOULDER TAPERSHOULDER WIDTH x SPEED / 3(EXTRACTED FROM APPENDIX 1-1, OF THE WORK ZONE TRAFFIC CONTROL GUIDELINES- M54-44, 2012) ONE LANE TWO WAY TAPER 50' MIN / 100' MAXTAPER/ CHANNELIZING DEVICE TABLEMERGING, SHIFTING, AND SHOULDER TAPER LENGTHS AND NUMBER OF CHANNELIZATION DEVICES USED(WASHINGTON STATE DEPARTMENT OF TRASPORTATION)(ALL MINIMUMS) RURAL HIGHWAYSRURAL ROADSRURAL ROADS & URBAN ARTERIALSRURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTSURBAN STREETS(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. 50 / 65 MPH45 / 55 MPH35 / 40 MPH25 / 30 MPH25 MPH OR LESS 800' +/-500' +/-200' +/- (2)100' +/- (2)350' +/-SIGN SPACING = X (1) CHANNELIZING DEVICE SPACING (FEET)MPH TAPER TANGENT50/7035/4525/30 40'40'30'20'80'60'ONE LANE TWO WAY TTC ZONE TAPER 20'TANGENT 40' SPACING AT ALL SPEEDS UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:JORGIA DURR, TCS # ES2 000149, jd.durr@outlook.com WORK AREA10' X 150'MH 665 ROADWORKAHEAD ROADWORKAHEAD ROADWORKAHEAD ROADWORKAHEAD RIGHT LANECLOSEDAHEAD SW 7TH ST @ OAKESDALE AVE SWMH 665 ACCESSRIGHT LANE CLOSURE X X X X X X SComments: THIS IS TO ACCESS MH 665THIS IS A RIGHT LANE CLOSURESIDEWALK ACCESSIBLE AT WORK AREASPOTTER WILL ASSIST PEDESTRIANS AT WORK AREAREFER TO CHARTS FOR SIGN SPACING, DEVICE SPACING AND TAPER LENGTHS RIGHT LANECLOSEDAHEADRIGHT LANECLOSEDAHEAD X www.invarion.comMFP24002925 TRAFFIC CONTROL PLANJOB # N.973435.C.46PERMIT # LegendArrowboard (Chevron)CONESMANHOLESSPOTTERWORK AREAWORK TRUCKDate:6/4/2024 Author:Darlene Durr, Traffic Control Supervisor Project:N.973435.C.46TCS CERT:#ES2 000148 DESIGNED FOR LUMEN:(DO NOT ALTER)Comments: General Requirements1. All signs and spacing to conform to the MUTCD and City of RENTONrequirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified.4. Alert affected local residents and businesses.5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be DETERMINED BY CITY, COUNTY AND/OR WSDOT. UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:DARLENE DURR, TCS #ES2 000148, darlene.durr@hotmail.com NOT TO SCALE6/4/2024Darlene DurrTCS # ES2 000148Phone 253-737-5198darlene.durr@hotmail.com_______________________Darlene Durr NOTE ALL LANE WIDTHS ARE ESTIMATES;FOR ACCURANCY, MEASURE IN FIELDPRIOR TO WORK.REFER TO CHARTS FOR DEVICESPACING, SIGNAGE SPACING, SIGN SIZE,BUFFER SPACING AND TAPER LENGTHS.CHANNELIZING DEVICE SPACING (FEET)MPH TAPER TANGENT50/7035/4525/30 40'40'30'20'80'60'ONE LANE TWO WAY TTC ZONE TAPER 20'TANGENT 40' SPACING AT ALL SPEEDS RURAL HIGHWAYSRURAL ROADSRURAL ROADS & URBAN ARTERIALSRURAL ROADS, URBAN ARTERIALS,RESIDENTIAL & BUSINESS DISTRICTSURBAN STREETS(1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS.50 / 65 MPH45 / 55 MPH35 / 40 MPH25 / 30 MPH25 MPH OR LESS 800' +/-500' +/-200' +/- (2)100' +/- (2)350' +/-SIGN SPACING = X (1)MERGING DEVICES DEVICESSHIFTING12 FEETL1/2 L 770 6 681016151934559999971111181820 40607522525027511511516529549555060566071585150305330370385 MERGING DEVICES DEVICESSHIFTING11 FEETL1/2 LMERGINGDEVICESDEVICESSHIFTING10 FEETL1/2 L 666633344772025303540455055606570 2535507015090170185200220200 DEVICESLENGTHMPHSHOULDER TAPERSASSUMES 10' SHOULDER2025303540455055606570 MPHLANEWIDTH 70065060055050045027020515010570 668810161614151719 355575105135225250275300325350 68810 3455999 66060080125180245320540720780840 6101619199718222112 406530033090125160270360390420 101034556991112 SHOULDER TAPERSHOULDER WIDTH x SPEED / 3(EXTRACTED FROM APPENDIX 1-1, OF THE WORK ZONE TRAFFIC CONTROL GUIDELINES- M54-44, 2012) ONE LANE TWO WAY TAPER 50' MIN / 100' MAXTAPER/ CHANNELIZING DEVICE TABLEMERGING, SHIFTING, AND SHOULDER TAPER LENGTHS AND NUMBER OF CHANNELIZATION DEVICES USED(WASHINGTON STATE DEPARTMENT OF TRASPORTATION)(ALL MINIMUMS) L ROADWORKAHEADW20-1ROADWORKAHEADW20-1RI GHT LANECLOSEDAHEADW20-5W4-2MH 670XXX X SPEEDLIMIT35 OAKESDALE AVE SWOAKESDALE A V E S WROADWORKAHEADW20-1ROADWORKAHEADW20-1 X X WORK AREA+/-11' X 300'SW GRADY WAYSW GRADY WAYComments: THIS IS TO ACCESS MH 670 FOR SPLICING.THIS IS A RIGHT LANE CLOSURE.SIDEWALK IS ACCESSIBLE AT WORK AREA.SPOTTER WILL ASSIST PEDESTRIANS AT WORK AREA.DRIVEWAYS REMAIN ACCESSIBLE AT WORK AREA.*REFER TO CHARTS FOR SIGN SPACING, DEVICE SPACING AND TAPER LENGTHS.NOAKESDALE AVE SW @ SW GRADY WAYMH 670 ACCESSRIGHT LANE CLOSURE S www.invarion.comMFP24002925 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:GEO CODE:WC CLLI:TOTAL EXISTING CONDUIT USED:TOTAL NEW BORE:TOTAL NEW DIRT TRENCHESTIMATED TOTALSTOTAL NEW AERIAL:SIDEWALK (PCC) R&R:ASPHALT (AC) R&R:S.F.S.F.L.F.L.F.L.F.L.F.TOTAL NEW ASPHALT TRENCH:L.F.TOTAL NEW S/W TRENCH:L.F.36500000000”NVICINITY MAPCUSTOMER NAME: KING COUNTYLCON: RYAN BELLPHONE NO: 206-850-8783EMAIL:  rybell@kingcounty.govWFMT #:  A.2908678ORDER #: N26440285ARMOR OR DSR #: 0216-2220758SCOPE OF WORK:POF: @ MANHOLE 113, SPLICE COUNT LRE27, 21-22 TO 216-FIBER [UA68] COUNT WILL FALL TO MANHOLE 110. @ MANHOLE 110, SPLICE COUNT TO NEW 72-FIBER.PLACE NEW 72-FIBER THRU MANHOLES 116, 117, 120, 169 & 661 IN EXISTING CONDUIT APPROX 3200' TO MANHOLE 665. @ MANHOLE 665, SPLICE COUNT TO 96-FIBER[A3G9Q] COUNT WILL FALL TO MANHOLE 668. @ MANHOLE 668, SPLICE COUNT TO 96-FIBER [SN30] COUNT WILL FALL TO MANHOLE 351. @ MANHOLE 351, SPLICECOUNT TO NEW 24-FIBER. PLACE NEW 24-FIBER THRU MANHOLE 714 APPROX 688'. @ MANHOLE 714, SPLICE COUNT TO NEW 24-FIBER. PLACE NEW 24-FIBER THRUMANHOLE 714 APPROX 40' TO OLD CLOSURE. @ OLD CLOSURE, REPLACE WITH 17X30 HANDHOLE & CONTINUE TO PLACE APPROX 332' OF NEW 24-FIBER THRU TO2nd NEW HANDHOLE. @ NEW HANDHOLE 2, TRENCH & PLACE 125' OF NE 24CT FIBER IN 1-2" CONDUIT TO BUILDING. @ BUILDING, CORE DRILL CONCRETE CINDERBLOCK TO MAKE WALL PENETRATION THEN CONTINUE TO PLACE NEW 24CT FIBER TO CUSTOMER'S MPOP. @ CUSTOMER'S MPOP, PLACE NEW EQUIPMENT.MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comDRAFTED BY: MOUNTAIN LTD/SL 03/08/2223N4E13N.973435W26226RNTNWA01550 MONSTER ROAD SWRENTON, WA 98057111FIBER ENGINEER: HALEY MADSENPHONE NO: (720) 394-3609EMAIL: haley.madsen@lumen.comRREVISION # SHEET # REASON FOR REVISION REVISED BY DATEREVISION - V2 1 & 11 UPDATE MH 714, ADD 2 HHS, TRENCH & UPDATE SOW & NOTES SL 05/22/24MFP24002925This permit is for Major construction work in the ROW and will be billed at an additional$158/HR for inspections. After hours and weekend work will be billed at $175/HR TTEE CATV CATV CATV GG TS TS WW S S SD SD IRRIG IRRIG C/L C/L R/W R/W R/W P/L P/L B/C B/C B/C EOP EOP TTTUSAMEEPWREETVTVVTSVWSSDVETTTXXX'XXX'XXX'XXX'XITEM #STATIONHT-CL-YRPROPOSED HOAPOLE NUMBER(S) - CTL/PWR/OTHERITEM#STAHT-CL-YRXX'-X"POLE#MAKE READYEXISTING ATTACHMENTSNOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF RNGE:SECT:TOWN:GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSMT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: HALEY MADSENPHONE NO: (720) 394-3609EMAIL: haley.madsen@lumen.comRDRAFTED BY: MOUNTAIN LTD/SL 03/08/2223N4E13N.973435W26226RNTNWA01550 MONSTER ROAD SWRENTON, WA 98057211MFP24002925 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS. EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/ W R/W R/W R/W R/W R/W R /W EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R/W R/W R /W R/W R/W R/W R/W EOP EOP EOP 31'11'SPEEDLIMIT35T13'14'333PARCEL#1923059072225PARCEL#1923059109300PARCEL#1823059253NOTE:POF: @ MANHOLE 113, SPLICECOUNT LRE27, 21-22 TO216-FIBER [UA68] COUNT WILLFALL TO MANHOLE 110.POF LMN MH 113 SW 7th STREETSIDEWALK6' SIDEWALK9' PLANTERPLANTER11'10'11'11'37'40'4' PLANTERDRIVEWAY DRIVEWAY DRIVEWAY DRIVEWAYMT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: HALEY MADSENPHONE NO: (720) 394-3609EMAIL: haley.madsen@lumen.comRDRAFTED BY: MOUNTAIN LTD/SL 03/08/2223N4E13N.973435W26226RNTNWA01550 MONSTER ROAD SWRENTON, WA 98057311MFP24002925 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.SPEEDLIMIT35NOTE:@ MANHOLE 110, SPLICE COUNTTO NEW 72-FIBER. PLACE NEW72-FIBER THRU MANHOLE 116. EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R /W R/W R/W R/W R/W R /W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W LIND AVE SW 4' PLANTER T0+00 LMN MH 110 37'12'40'12'39'20' EOP EOP EOP EOP 720PARCEL#1923059060501PARCEL#1923059056DRIVEWAYSW 7th STREET5' SIDEWALK5' SIDEWALK9' PLANTER7' PLANTER12'12'12'39'440PARCEL#1823059252550PARCEL#18230592516' SIDEWALK 11'11'11'11'MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: HALEY MADSENPHONE NO: (720) 394-3609EMAIL: haley.madsen@lumen.comSEE SHEET 5R DRAFTED BY: MOUNTAIN LTD/SL 03/08/2223N4E13N.973435W26226RNTNWA01550 MONSTER ROAD SWRENTON, WA 98057411MFP24002925 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS. EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP C/L C/L C/L C/L R/W R/W R/W R/W R/W R /W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W T7+00 LMN MH 117NOTE:@ MANHOLE 117, SPLICECOUNT TO NEW 72-FIBER.PLACE NEW 72-FIBER THRUMANHOLE 120.8'17'28'SENECA AVE SW SW 7th STREET5' SIDEWALK5' SIDEWALK9' PLANTER7' PLANTER333PARCEL#1923059072333PARCEL#192305907211'11'11'11'40'44'SPEEDLIMIT35MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: HALEY MADSENPHONE NO: (720) 394-3609EMAIL: haley.madsen@lumen.com E O P T3+50 LMN MH 116 EOP E O P EOP E O P EOP NOTE:@ MANHOLE 116, SPLICECOUNT TO NEW 72-FIBER.PLACE NEW 72-FIBER THRUMANHOLE 117.6'SEE SHEET 4RDRAFTED BY: MOUNTAIN LTD/SL 03/08/2223N4E13N.973435W26226RNTNWA01550 MONSTER ROAD SWRENTON, WA 98057511SEE SHEET 6MFP24002925 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: HALEY MADSENPHONE NO: (720) 394-3609EMAIL: haley.madsen@lumen.comRDRAFTED BY: MOUNTAIN LTD/SL 03/08/2223N4E13N.973435W26226RNTNWA01550 MONSTER ROAD SWRENTON, WA 98057611SEE SHEET 5 SEE SHEET 7 EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP C/L C/L C/L R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R/W R/W R/W R/W R/W R /W R/W R/W R/W R/W R/W THOMAS AVE SW SW 7th STREETSIDEWALK6' SIDEWALK8' PLANTERPLANTER11'11'11'11'40'44'SPEEDLIMIT35 R/W R/W R/W R/W R /W R/W R/W R/W R/W R /W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP T13+00 LMN MH 120NOTE:@ MANHOLE 120, SPLICE COUNTTO NEW 72-FIBER. PLACE NEW72-FIBER THRU MANHOLE 169.6'26'MFP24002925 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.T19+00 LMN MH 169NOTE:@ MANHOLE 169, SPLICECOUNT TO NEW 72-FIBER.PLACE NEW 72-FIBER THRUMANHOLE 661.6' EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP C/L C/L C/L C/L C/L R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W 18'POWELL AVE SW SW 7th STREET5' SIDEWALK5' SIDEWALK9' PLANTER7' PLANTER11'11'11'11'36'44'SPEEDLIMIT3518' EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EO P EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W 711PARCEL#08502000001100PARCEL#91880000501000PARCEL#9188000020700PARCEL#2146100015SPEEDLIMIT30MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: HALEY MADSENPHONE NO: (720) 394-3609EMAIL: haley.madsen@lumen.comRDRAFTED BY: MOUNTAIN LTD/SL 03/08/2223N4E13N.973435W26226RNTNWA01550 MONSTER ROAD SWRENTON, WA 98057711SEE SHEET 6 SEE SHEET 8MFP24002925 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: HALEY MADSENPHONE NO: (720) 394-3609EMAIL: haley.madsen@lumen.com EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EO P EOP EOP EO P EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EO P EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W NACHESAVE SWSW 7th STREET5' SIDEWALK5' SIDEWALKTNOTE:@ MANHOLE 661, SPLICE COUNTTO NEW 72-FIBER. PLACE NEW72-FIBER THRU TO MANHOLE 665.18'33'1217PARCEL#0850200000SPEEDLIMIT25SPEEDLIMIT3524+00 LMN MH 661 11'11'11'11'39'41'RDRAFTED BY: MOUNTAIN LTD/SL 03/08/2223N4E13N.973435W26226RNTNWA01550 MONSTER ROAD SWRENTON, WA 98057811SEE SHEET 7 SEE SHEET 9MFP24002925 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.30+50 LMN MH 665NOTE:@ MANHOLE 665, SPLICE COUNTTO 96-FIBER [A3G9Q] COUNT WILLFALL TO MANHOLE 668.MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: HALEY MADSENPHONE NO: (720) 394-3609EMAIL: haley.madsen@lumen.comRDRAFTED BY: MOUNTAIN LTD/SL 03/08/2223N4E13N.973435W26226RNTNWA01550 MONSTER ROAD SWRENTON, WA 98057911 EOP EOP EOP EOP E O P E O P E O P E O P E O P EO P E O P R/W R/W R/W R/W R/W R /W R/W R /W R/ W R/W R/W R/ W R /W R/W R/ W R /W EOP EOP EOP EOP EOP EOP EOP EOP EOP E O P E O P E O P EO P E O P R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R /W R/W R/ W R/W R/W EOP EOP E O P E O P EOP EOP EOP R/W R/W R/W R /W R/W R/W R/W R/W R/W EOP EOP EOP E O P E O P EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W C/L C/L C/L C / L C/ L OAKESDALE AVE SW6' SIDEWALK6' GRASSS W 7 t h S T R E E T 5' S I D E W A L K 5' S I D E W A L KT35'15'11'45'150'OAKESDALE CENTER600-606PARCEL#9188000143BLACK RIVER11'13'12'12'46'11'32'11'13'12'12'SPEEDLIMIT35800PARCEL#91880001454' G R A S S 4' G R A S SPARCEL#2423049098SEE SHEET 8MFP24002925 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: HALEY MADSENPHONE NO: (720) 394-3609EMAIL: haley.madsen@lumen.comRDRAFTED BY: MOUNTAIN LTD/SL 03/08/2223N4E13N.973435W26226RNTNWA01550 MONSTER ROAD SWRENTON, WA 980571011 EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/ W R /W R /W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP C/L C/L C/L C/L MONSTER ROAD SW 5' SIDEWALK 37'10'12'43'108'37'OAKESDALE AVE SWSPEEDLIMIT35SPEEDLIMIT30NOTE:@ MANHOLE 668, SPLICE COUNTTO 96-FIBER [SN30] COUNT WILLFALL TO MANHOLE 351.12'12'T LMN M H 6 6 8 R/W R/W 12'12'11'11'PARCEL#2423049044PARCEL#13230490781200PARCEL#2423049006DRIVEWAYMFP24002925 NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.TT EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP MONSTER ROAD SWSIDEWALK35SPEEDLIMITNOTE:@ MANHOLE 351, SPLICECOUNT TO NEW 24-FIBER.PLACE NEW 24-FIBER THRUMANHOLE 714 APPROX 688'.0+00 LMN MH 351 6+88 LM N M H 7 1 4 NOTE:@ MANHOLE 714, SPLICE COUNT TONEW 24-FIBER. PLACE NEW 24-FIBERTHRU MANHOLE 714 APPROX 40' TOOLD CLOSURE.NOTE:@ CUSTOMER'S MPOP,PLACE NEW EQUIPMENT.550MONSTER ROAD SWPARCEL#3779200090 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W 0'38'555PARCEL#2423049120601PARCEL#2423049008T10+60 LMN HH 2NOTE:@ NEW HANDHOLE 2,TRENCH & PLACE 125' OFNE 24CT FIBER IN 1-2"CONDUIT TO BUILDING.11+00 BLDGNOTE:@ BUILDING, CORE DRILLCONCRETE CINDER BLOCK TOMAKE WALL PENETRATION THENCONTINUE TO PLACE NEW 24CTFIBER TO CUSTOMER'S MPOP.T50'33' 7+28 RE P L A C E P E D W / H H 1 11+83 MPOPNOTE:@ OLD CLOSURE, REPLACE WITH 17X30HANDHOLE & CONTINUE TO PLACE APPROX 332'OF NEW 24-FIBER THRU TO 2nd NEW HANDHOLE.PARCEL#2423049078PLANTER GRADE SOFT, ASPHALT &CONCRETE SURFACE36" MIN TRENCH/BORE DETAIL 'A'TRENCH/BORE PLACEMENT OF 2" CONDUIT - 36" MINN.T.S.6"MIN.2" CONDUIT20'12'12'14'SIDEWALKNOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comFIBER ENGINEER: HALEY MADSENPHONE NO: (720) 394-3609EMAIL: haley.madsen@lumen.comRDRAFTED BY: MOUNTAIN LTD/SL 03/08/2223N4E13N.973435W26226RNTNWA01550 MONSTER ROAD SWRENTON, WA 980571010MFP24002925POTHOLE ALL EXISTING UTILITIESRESTORATION PER CITY OF RENTON STANDARDS