Loading...
HomeMy WebLinkAboutMFP24002990.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP24002990 IVR Number: 24002990 Permit Information Permit Name: P.073317 Address/Location:06/11/2024Application Date:7231501245Parcel Number: 207 MAIN AVE S Permit Type:06/27/2024Issue Date:Franchise Permit Work Class:06/27/2025Expiration Date:Minor Utility Job Number: P.073317Franchise Type:Telephone Description: Access MH 2 and MH 1 1 for splicing. Contacts Name Address PhoneTypeBilling Merilyn Luong Lumen B: (206) 806-7160 C: (206) 806-7160 Applicant Nathan Macleod Lumen 7850 S Trafton St, Bldg B Tacoma, WA 98409 C: (253) 583-6283ApplicantX Michael Smith North Sky Communications 21320 84th Ave S Kent, WA 98032 C: (206) 305-5881Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner QWest/Century Link - Billing 23315 66th Ave S Kent, WA 98032 Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 3/18/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 3/18/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐ Electronic Copy of the TCP Application ☐ Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall: ▪ Include map(s) showing the location of the project and work area. ▪ Be legible lettering and clear, contrasting, symbols of viewing or printing. ▪ Must indicate street names, and north arrow and scale. ▪ Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering P.073317 207 Main Ave S 8AM 5PM 8AM 5PM Northsky Communications Mike Smith 206-306-5814 16701 SE McGillivrary Blvd Vancouver WA 98683-3462 Access MH 1-1 and MH 2 for splicing. MFP24002990 Scott Warlick CED 6/27/2024 Monday Friday 3:00pm Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 3/18/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING: • Must have approved Traffic Control Plan (TCP) prior to commencing the work. • Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. • WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way. • Comply with all traffic regulations of the City of Renton and the State of Washington. • Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. • Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. • Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. • Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. • The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. • In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. • Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. • All permit conditions shall be met. NOTES: • Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. • Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT. • Approved Temporary Traffic Control Plan must be at the work site during work hours. • Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure. • Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. • Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. • Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. • In the case of Temporary No Parking Zones, all the following apply in addition to previous: • Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. • Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 3/18/2021 • The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. • Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) Merilyn Luong 6/11/2024 WILLIAMS AVE S @ S 2ND STWORK @ MH-2SHOULDER WORKComments: WORK @ MH-2 LOCATED OFF ROADWAY.SHOULDER WORK. NO TRAFFIC IMPACT.RESTRICTED PARKING IN WORK ZONE.DRIVEWAYS REMAIN OPEN/ACCESSIBLE.SIDEWALKS REMAIN OPEN/ACCESSIBLE.MAINTAIN 4' MINIMUM WALKWAY WIDTH.SPOTTER WILL ASSIST AT WORK AREA.TRAFFIC CONTROL PLANJOB # P. 227497. C. 45PERMIT # LEGENDCONESSPOTTERSSPOTTERTRAFFIC LIGHT WORK AREAWORK TRUCK NDate:6/11/2024 Author:Jeffrey D. Hubbard, Traffic Control Supervisor Project:________________CERT:WA TCS # ES2000151 (Exp: 4/2027)DESIGNED FOR:LUMEN LOCATION:RENTON, WAComments: General Requirements1. All signs and spacing to conform to the MUTCD and CITY OF RENTON Requirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 36" x 36" B/O unless otherwise specified.4. Alert affected local residents and businesses.5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be determined by CITY OF RENTON. NOT TO SCALEComments: MERGING TAPER LENGTHTAPER ("L") LANE WIDTH L MPH 10' 11' 12'SHIFTING 20 70 75 80TAPER 25 105 115 1651/2 L 30 150 165 180 35 205 225 245SHOULDER 40 270 295 320TAPER 45 450 495 5401/3 L 50 500 550 600 TCP PROPOSAL: NOT VALID W/O R-O-W JURISDICTION APPROVAL STAMPUNLAWFUL FOR ANYONE (OTHER THAN R-O-W APPROVAL JURISDICTION)TO ALTER W/O CONSENT FROM AUTHOR (JHUBBARD.TCP@GMAIL.COM) DESIGNED FOR: LUMENJeffrey D. HubbardTraffic Control SupervisorWA TCS # ES2 000151Draw Date: 6/11/2024Phone 253-737-5198jhubbard.tcp@gmail.com_______________________X200' +-ROADWORKAHEADW20-1SHOULDERWORKW21-5X200' +-SPOTTERSWORK@ MH-2WORK AREA8' X ~50'X200' +-ROADWORKAHEADW20-1 X200' +-ROADWORKAHEADW20-1 X200' +-ROADWORKAHEADW20-1ONE WAYONE WAY11 11 11 11 11 111111NOFROMTOTOW AWAY AREAPHON E 6 84 -5 44 4YOUR CO M PA NY NA ME 55 5- 55 55PARKING SPEEDLIMIT25SPEEDLIMIT25 SPEEDLIMIT25SPEEDLIMIT25 2020SIDEWALKSIDEWALKPARKING SIDEWALKSIDEWALKSIDEWALKSIDEWALKPARKINGWILLIAMS AVE S WILLIAMS AVE SS 2ND STwww.invarion.comMFP24002990 TRAFFIC CONTROL PLANJOB # P.227497.C.45PERMIT # LegendWork AreaWORK TRUCKPUNIFORMED POLICE OFFICERCONESSSPOTTERFLAGGER N Designed For: LUMENProject # P.227497.C.45Kathy HubbardTraffic Control SupervisorTCS # ES2 000152Drafted 6-10-24Phone 253-737-5198tcpnd@comcast.net_______________________Kathy HubbardDate:6/10/24 Author:Kathy Hubbard, Traffic Control Supervisor Project:P.227497.C.45CERT:TCS # ES2 000152 LUMEN:(DO NOT ALTER)Comments: General Requirements1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48" x 48" B/O unless otherwise specified.4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width.6. Work hours will be determined by City of Renton. UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TOALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:KATHY HUBBARD, TCS# ES2 000152, tcpnd@comcast.net ONE LANE TWO WAY TAPER 50' MIN/100' MAXCHANNELIZING DEVICE SPACING (FEET)MPH TAPER TANGENT50/7035/4525/30 40 4030208060NOT TO SCALE S 2ND STMAIN AVE SS 2ND ST BRONSON WAY SPARKINGPARKINGPARKINGPARKINGPARKING PARKINGMAIN AVE SS 2ND ST @ MAIN AVE SMH 1-1 SPLICINGONE LANE TWO WAY TRAFFIC SPEED LIMIT25 P S NOPARKINGFROMTOTOW AWAY AREAPHONE 685-5444YOUR COMPANY NAME 555-5555R7-T39 NOPARKINGFROMTOTOW AWAY AREAPHONE 685-5444YOUR COMPANY NAME 555-5555R7-T39 ROADWORKAHEADW20-1 ROADWORKAHEADW20-1 ROADWORKAHEADW20-1 BE PREPAREDTO STOPW20-7b BE PREPAREDTO STOPW20-7b BE PREPAREDTO STOPW20-7b BE PREPAREDTO STOPW20-7b BE PREPAREDTO STOPW20-7b BE PREPAREDTO STOPW20-7b ROADWORKAHEADW20-1 W20-7a W20-7a W20-7a W20-7a ROADWORKAHEADW20-1ROADWORKAHEADW20-1 SIDEWALK CLOSEDCROSS HERER9-11a(L) SIDEWALK CLOSEDCROSS HERER9-11a(R) MH 1-1 Comments: THIS IS TO ACCESS THE MH 1-1 FOR SPLICING.THIS WILL BE ONE LANE TWO WAY TRAFFIC ON S 2ND ST.POLICE OFFICER WILL ASSIST AT THE INTERSECTION.EAST SIDE CROSSWALK IS CLOSED ANDPEDESTRIANS ARE ROUTED TO OTHER CROSSWALKS.SPOTTER WILL ASSIST PEDESTRIANS AT WORK AREA.PARKING IS RESTRICTED IN WORK AREA ONLLY.**REFER TO CHARTS FOR SIGN AND DEVICE SPACING.**UPO WORK AREA8' X 50' www.invarion.comMFP24002990 Fire station located here. Maintain access for emergency vehicles. NOTICE-NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB: BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:GEO CODE: WC CLLI:TOTAL EXISTING CONDUIT USED:TOTAL NEW BORE:TOTAL NEW DIRT TRENCHESTIMATED TOTALSTOTAL NEW AERIAL:SIDEWALK (PCC) R&R:ASPHALT (AC) R&R:S.F.S.F.L.F.L.F.L.F.L.F.TOTAL NEW ASPHALT TRENCH:L.F.TOTAL NEW S/W TRENCH:L.F.00000000”NVICINITY MAPSL207 MAIN AVE SRENTON, WA 98057P.073317W26226KENTWA0123N5E2904/30/2441®SH OF DRAFTED BY: MOUNTAIN LTD/MT LTD ENGINEER: RICK FERDINANDOPHONE NO: 206-276-3165EMAIL: rick.ferdinando@lumen.comCUSTOMER NAME: DISHLCON: N/APHONE #: N/AEMAIL: n/aWFMT #:  N/AORDER #: N/AARMOR OR DSR #: N/ASCOPE OF WORK:POF: @ MANHOLE 2, SPLICE COUNT WITH LRE30, 215-216 FROM [A2VKA] ONTO [A2WGT] FALLING TOMANHOLE 1-1. @ MANHOLE 1-1, SPLICE COUNT FROM [A2WGT] ONTO [F1] FALLING TO CUSTOMER BUILDINGMPOP. @ CUSTOMER'S MPOP, PLACE NEW EQUIPMENT & TERMINATE LGL24, LRE30, 215-216 IN FDP.FIBER ENGINEER: ZACHARY THATCHERPHONE NO: 253-797-4657EMAIL: zachary.thatcher@lumen.comMFP24002990 TT TTTEE EEE CATV CATV CATV CA TV CATV CATV CATV CATV GG GGG TS TS TS TS TS WWWWW S S S S S SD SD SD SD SD C/L C/L C/ L C/L C/L C/ L R/W R/W R/W R/W R/W R/W R/W P/L P/L P/L P/L P/L P/L B/C B/C B/C B/C B/C B/C B/C B/ C EOP EOP EOP EOP EOP TTTUSAMEEPWREE CAT V CATV TVTV CATV CATV CATV CATV CATV CATV CATV CATV VTS C/L C/L VWSSDVETTTXXX'XXX'XXX'XXX'X IRRIG IRRIG F1TTTTTTNOTICE-NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB: RNGE:SECT:TOWN:GEO CODE: WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:JOB:GEO CODE:WC CLLI:DRAFTED BY: MOUNTAIN LTD/SH OF SL207 MAIN AVE SRENTON, WA 98057P.073317W26226KENTWA0123N5E2904/30/2442®MT LTD ENGINEER: RICK FERDINANDOPHONE NO: 206-276-3165EMAIL: rick.ferdinando@lumen.comFIBER ENGINEER: ZACHARY THATCHERPHONE NO: 253-797-4657EMAIL: zachary.thatcher@lumen.comMFP24002990 NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.T EOP EOP EOP C/L C/L C/L EOP EOP EOP EOP EOP EOP EOP EOP C/L C/L C/L R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W E O P EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W POF LMN MH 2S 2nd STREETONE-WAYSIDEWALKSIDEWALKPARKINGWELLS AVE S SIDEWALK PARKING PARKING SIDEWALK WILLIAMS AVE S SIDEWALK PARKING SIDEWALK BURNETT AVE SSIDEWALK 25SPEEDLIMITNOTE:POF: @ MANHOLE 2, SPLICECOUNT WITH LRE30, 215-216FROM [A2VKA] ONTO [A2WGT]FALLING TO MANHOLE 1-1.201PARCEL#7231501825858PARCEL#7231501979710PARCEL#7231502085201PARCEL#723150226526' R/W R/W R/W R/W R/W R/W R/W R/W R/W R/ W R/W R/W R/W R/W 33' 11'11'11'5'29'29'12'12' EOP EOP EOP BURNETT AVE SSIDEWALK EOP EOP EOP EOP EOP EOP NOTICE-NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB: GEO CODE: WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYS3RSL207 MAIN AVE SRENTON, WA 98057P.073317W26226KENTWA0123N5E2904/30/244SH OF DRAFTED BY: MOUNTAIN LTD/MT LTD ENGINEER: RICK FERDINANDOPHONE NO: 206-276-3165EMAIL: rick.ferdinando@lumen.comFIBER ENGINEER: ZACHARY THATCHERPHONE NO: 253-797-4657EMAIL: zachary.thatcher@lumen.comMFP24002990 NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.T EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP E O P EOP EOP R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP C/L C/L C/L C/L C/L EOP EOP R/W R/W R/W R/W R/W R/W R/W S 2nd STREET2-WAYSIDEWALKLMN MH 1-1MAIN AVE S PARKING S 2nd STREETONE-WAYSIDEWALKSIDEWALK EOP R/W R /W R /W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W SIDEWALK SIDEWALKPARKINGSIDEWALK BR O N S E N W A Y S SI D E W A L K PA R K I N G SI D E W A L K MAIN AVE S SIDEWALK SIDEWALK MILL AVE S SIDEWALK 25SPEEDLIMITNOTE:@ MANHOLE 1-1, SPLICE COUNTFROM [A2WGT] ONTO [F1] FALLINGTO CUSTOMER BUILDING MPOP.NOTE:@ CUSTOMER'S MPOP, PLACENEW EQUIPMENT & TERMINATELGL24, LRE30, 215-216 IN FDP.207MAIN AVE SPARCEL#72315012451005PARCEL#7231500860916PARCEL#72315011101000PARCEL#723150102031'26'11'11'11'11' 33'30' 11'11'28'34'11'11'11'3' EOP EOP EOP EOP NOTICE-NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB: GEO CODE: WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSSL207 MAIN AVE SRENTON, WA 98057P.073317W26226KENTWA0123N5E2904/30/2444RSH OF DRAFTED BY: MOUNTAIN LTD/MT LTD ENGINEER: RICK FERDINANDOPHONE NO: 206-276-3165EMAIL: rick.ferdinando@lumen.comFIBER ENGINEER: ZACHARY THATCHERPHONE NO: 253-797-4657EMAIL: zachary.thatcher@lumen.comMFP24002990