Loading...
HomeMy WebLinkAboutR-424807J J w ❑ J Z w U_ m ❑ A TRUNCATED DOME SPACING SEE NOTE 3 WALKWAY CURB RAMP E — C �Z L f B t D TRUNCATED DOME SECTION O SEE STANDARD SPECIFICATIONS FOR COLOR OF SURFACE MIN. MAX. A 1.60" 2.40" B 0.65" — C 0.45" 0 90" D 0.9" 1.40" E 0.2" 0.2" TRUNCATED DOME DETAILS W Y ❑ ¢ O m LANDING OFFSET SEE NOTE 7 WIDTH OF WALKWAY DETECTABLE WARNING SURFACE (DWS) SEE NOTE 3 BACK OF CURB SINGLE DIRECTION CURB RAMP (GRADE BREAK BETWEEN CURB AND LANDING s 5 FT. FROM BACK OF CURB) (SEE NOTE 5) CURB RAMP WALKWAY w Y LANDING w � m BACK OF CURB - SEE NOTE 2 SINGLE DIRECTION CURB RAMP (GRADE BREAK BETWEEN CURB AND LANDING > 5 FT. FROM BACK OF CURB) (SEE NOTE 5) WHEELCHAIR DIRECTION OF TRAVEL WALKWAY CURB RAMP, LANDING, CUT - THROUGH OR WALKWAY SEE TRUNCATED DOME DETAIL - THIS SHEET BACK OF CURB SEE NOTE 2 DETECTABLE WARNING SURFACE (DWS) SEE NOTE 3 2' - 0" MIN. TYP. OF ALL APPLICATIONS CURB AND GUTTER 1 LANDING, CUT -THROUGH OR WALKWAY DETECTABLE WARNING SURFACE DETAIL W1IIB71kI[ei 9I_1Nq BACK OF CURB SEE NOTE 2 WALKWAY CURB RAMP FLARE DETECTABLE WARNING SURFACE (DWS) SEE NOTE 3 WIDTH OF CURB RAMP 7TWIDTH OF PERPENDICULAR CURB RAMP WALKWAY (SEE NOTE 6) WIDTH OF CURB RAMP, LANDING, OR WALKWAY DETECTABLE WARNING SURFACE (DWS) SEE NOTE 3 DETECTABLE WARNING SURFACE (DWS) SEE NOTES 3 & 6 CURB RAMP CURB RAMP WALKWAY � LANDING WALKWAY DETECTABLE SURFA SEE NOT WIDTH OF CUT - THROUGH (TYP.) i NOTES 1. Permanent Detectable Warning Surfaces (DWS) shall extend the full width of the curb ramp, landing, or other roadway entrance as applicable. Exception: If the Manufacturer of the DWS requires a concrete border around the DWS, a variance of up to 2" (in) on each side of the DWS is permitted. 2. Permanent Detectable Warning Surfaces (DWS) shall be placed on a minimum 4" (in) thick concrete pad. The DWS panel shall be placed adjacent to the back of the curb and with no more than a 2" (in) gap between the DWS and the back of the curb measured at the center of the DWS panel. Exception: If the Manufacturer of the selected DWS requires a concrete border around the DWS, a variance of up to 2" (in) from the back of the curb is permitted (measured at the leading corners of the DWS panel). 3. The rows of truncated domes shall be aligned to be parallel to the direction of travel, and perpendicular to the grade break at the back of curb. 4. If curb and gutter are not present, such as a shared -use path connection, the Detectable Warning Surface shall be placed at the pavement edge. 5. See Standard Plans for sidewalk and curb ramp details. 6. If a curb ramp is required, the location of the Detectable Warning Surface must be at the bottom of the ramp and within the required distance from the rail crossing. 7. When the grade break between the curb ramp and the landing is less than or equal to 5 ft. from the back of curb at all points, place the Detectable Warning Surface on the bottom of the curb ramp directly above the grade break. 8. Glued or stick down Detectable Warning Surfaces are allowed only for temporary work zone applications. WIDTH OF CUT -THROUGH (TYP.) 2'- 0" MIN. RB 2'-0„ MIN. LEGEND DIRECTION OF TRAVEL ®F WASy1Z zm) Aug 30, 2021 ETECTABLE WARNING