HomeMy WebLinkAboutW-367401C)
i_�
N
►i
U
LU
O
rrz
LU
LU
U
Q
J
W
rrZ
Q
rr
W
H
Q
W
U
rrQ
rr
LU
W
rrLU
H
Z
O
CITY OF RENTON
MONTEREY TERRACE WATER MAIN REPLACEMENT PROJECT
FEBRUARY, 2014
VICI ITY MAP
NSCALE:1 "=1000'±
SHEET INDEX
DRAWING NO. SHEET NO.
TITLE
G-0
PLASTIC PIPE
1
COVER SHEET
®
AREA DRAIN
G-1
H/C PARKING SPACE
2
KEY MAP
CON
CONIFEROUS TREE
C-1
ASPHALT (ASPH)
3
MONTEREY DRIVE NE STA.
1 +00 TO STA.
6+00
C-2
DRIVEWAY
4
MONTEREY DRIVE NE STA.
6+00 TO STA.
12+00
C-3
BUILDING LINE
BUILDING CORNER
5
MONTEREY DRIVE NE STA.
12+00 TO
BOLLARD
EHH
ELECTRICAL HANDHOLE
(P)
MONTEREY PLACE NE STA.
3+00
ELECTRICAL METER
C-4
RECORDED UTILITY LOCATION
6
MONTEREY PLACE NE STA.
3+00 TO STA.
6+25
C-5
ELECTRICAL MANHOLE
7
MONTEREY PLACE NE STA.
6+25 TO STA.
9+75
C-6
CONCRETE SURFACE (CONC)
8
MONTEREY PLACE NE STA.
9+75 TO STA.
13+50
C-7
FIRE HYDRANT
9
CAPRI AVENUE NE STA. 2+25 TO STA. 7+00
D-1
FINISHED FLOOR ELEVATION
10
CONNECTION DETAILS
G
GAS MAINGM
D-2
CONCRETE/EXTRUDED CURB
11
PIGGING PLAN
CP/IP
CONC./IRON PIPE
D-3
GAS VALVE
12
TRENCH RESTORATION PLAN & TESC PLAN
S-1
GAS VAULT
13
TOPOGRAPHIC SURVEY
}
GUY ANCHOR
S-2
COLUMN
14
TOPOGRAPHIC SURVEY
S-3
15
TOPOGRAPHIC SURVEY
S-4
16
TOPOGRAPHIC SURVEY
S-5
17
TOPOGRAPHIC SURVEY
S-6
18
TOPOGRAPHIC SURVEY
S-7
19
TOPOGRAPHIC SURVEY
Know what's below.
�,_ Call before you dig.
RE SHOWN
ONE-CALLEXISTING REF REN ETILITIES ON Y ACONTRACTOR OR
SHALL FLOCATE
-800-424-5555 UTILTIESI ELD A MINIMUM OFL72XISTING HOURS
PRIOR TO CONSTRUCTION.
t'Y
ORIGINAL PLANS STAMPED BY:
ANDREW WEYGANDT ON:2/11/14
PE #44883
LEGEND
ADS
PLASTIC PIPE
CS
CONC. STAIRS
®
AREA DRAIN
&
H/C PARKING SPACE
ABAN/RET
ABANDONED/RETIRED
CON
CONIFEROUS TREE
—
ASPHALT (ASPH)
DEC
DECIDUOUS TREE
LSCAPE
BRICK SURFACE
DWY
DRIVEWAY
( O�
MANHOLE
ECd
ELECTRICAL CONDUIT (BURIED)
BC
BUILDING LINE
BUILDING CORNER
q' �
CENTERLINE/MONUMENT LINE
O
BOLLARD
EHH
ELECTRICAL HANDHOLE
(P)
PAINTED UTILITY LOCATION
EM
ELECTRICAL METER
XWICANOPY
RECORDED UTILITY LOCATION
==>
TRAFFIC FLOW DIRECTION
PPS
PARKING PAY STATION
EMH
ELECTRICAL MANHOLE
G) (v)
CATCH BASIN (CB)
EV/ET
ELECTRICAL VAULT/TRANSFORMER
PDQ
CONCRETE SURFACE (CONC)
9
FOUND MONUMENT IN CASE
CW/BW
CONCRETE/BRICK WALK
)D
FIRE HYDRANT
CRW
CONCRETE RETAINING WALL
FFE
FINISHED FLOOR ELEVATION
[+JPRIVATE
CATCH BASIN
G
GAS MAINGM
CC/XC
CONCRETE/EXTRUDED CURB
N
GAS METER
CP/IP
CONC./IRON PIPE
ISI
GAS VALVE
CHAIN LINK FENCE (CLF)
GV
GAS VAULT
CTV
CABLE TV
}
GUY ANCHOR
COL
COLUMN
IE
INVERT ELEVATION
'Y'
FIRE DEPT. CONNECTION (FDC)
SD
SERVICE DRAIN (STORM)
��
LIGHT POLE (METAL)
SD/SSCO
STORM/SEWER CLEANOUT
0--0
LIGHT POLE (WOOD)
SS(R)
SANITARY SIDE SEWER (RECORD)
LIGHT POLE (ORNAMENTAL)
±/-M
SIGN/STREET NAME SIGN
LSCAPE
LANDSCAPE PLANTER
TBM
TEMPORARY BENCHMARK
( O�
MANHOLE
TCd
TELEPHONE CONDUIT (BURIED)
OHP/T
OVERHEAD POWER/TELEPHONE
TV
TELEPHONE VAULT
PL
PROPERTY LINE
TMH
TELEPHONE MANHOLE
(P)
PAINTED UTILITY LOCATION
TS
TELEPHONE SENTRY
(R)
RECORDED UTILITY LOCATION
==>
TRAFFIC FLOW DIRECTION
PPS
PARKING PAY STATION
TOE
TOE OF SLOPE
POST—INDICATOR VALVE
TOP
TOP OF BANK
PDQ
UPO
UTILITY POLE (WOOD)
PS/PSS
COMBINED/SANITARY SEWER
WV
WATER VAULT
PSD
PIPE STORM DRAIN
W
NATER MAIN
[+JPRIVATE
CATCH BASIN
WM
WATER METER
GRAVEL SURFACE
N
WATER VALVE
®
(3)
WATER GATE VALVE/ CHAMBER
ROCKERY
RE
ROOF ELEVATION
SCL/CL
SEATTLE CITY LIGHT HANDHOLE
HORIZONTAL DATUM — NAD 1983/91
POSITIONS FOR COORDINATES ARE BASED ON WGS DATA POINT NUMBER RENT721,
MONUMENT IN CASE WITH TACK IN LEAD IN 4-3/8" CONCRETE FILLED IRON PIPE
DOWN 0.4' AT THE INTERSECTION OF NE 7TH STREET AND MONROE AVENUE NE.
NORTH 182,946.08588 EAST 1,308,746.67661
AND WGS DATA POINT RENT1936, MONUMENT IN CASE WITH TACK IN LEAD IN
CONCRETE DOWN 0.6' AT THE INTERSECTION OF NE 4TH STREET AND JEFFERSON
AVENUE NE.
NORTH 181,136.92325 EAST 1,307,890.861531
VERTICAL DATUM — NAVD 88
ELEVATIONS ARE BASED ON CITY OF RENTON CONTROL POINT NUMBER RENT721,
MONUMENT IN CASE WITH TACK IN LEAD IN 4-3/8" CONCRETE FILLED IRON PIPE
DOWN 0.4' AT THE INTERSECTION OF NE 7TH STREET AND MONROE AVENUE NE.
ELEVATION = 381.599 FEET
ELEVATIONS VERIFIED BY CITY OF RENTON CONTROL POINT RENT1936, MONUMENT IN
CASE WITH TACK IN LEAD IN CONCRETE DOWN 0.6' AT THE INTERSECTION OF NE 4TH
STREET AND JEFFERSON AVENUE NE.
ELEVATION = 326.381 FEET
SITE BENCHMARKS
TBM "A"
CHISELED SQUARE IN CONC. WALK
BACK OF CURB 12' N.E. OF M.I.C.
ELEVATION=220.82
TBM "B"
TOP CENTER BOLT FIRE HYDRANT
E. SIDE MONTEREY DR. N.E. APPROX.
340' S. OF MONTEREY PL. N.E.
ELEVATION=186.23
TBM "C"
CHISELED SQUARE IN BACK OF CONC.
WALK BACK E. SIDE MONTEREY DR. N.E.
S.E. OF ADDRESS "169", 8.5' N.E. OF
LIGHT POLE BASE
ELEVATION=138.14
TBM "F"
CHISELED SQUARE IN TOP BACK OF CURB
W. SIDE CAPRI AVE. N.E. BETWEEN
ADDRESS "147" AND "153"
ELEVATION=196.54
TBM "G"
CHISELED SQUARE IN BACK OF CONC.
WALK W. SIDE CAPRI AVE. N.E.
S.E. OF ADDRESS "117", 6.5' N.E. OF
A LIGHT POLE BASE
ELEVATION=229.73
TBM "H"
CHISELED SQUARE IN CONC. WALK TOP BACK
OF CURB E. SIDE MONTEREY PL N.E. BETWEEN
ADDRESS "152" AND "120"
ELEVATION=234.77
TBM "D"
CHISELED SQUARE IN TOP BACK OF CURB TBM "i"
W. COR. H/C RAMP, N.E.C. INT. 3rd ST. & CHISELED SQUARE IN BACK OF CONC.
MONTEREY DR. N.E. WALK E. SIDE MONTEREY PL N.E. BETWEEN
ELEVATION=105.89 ADDRESS "82" AND "76", 4' N.W. OF A
LIGHT POLE BASE
TBM "E" ELEVATION=254.69
CHISELED SQUARE IN TOP BACK OF CURB
S. SIDE MONTEREY PL. N.E. BETWEEN
ADDRESS "156" AND "153"
ELEVATION=166.40
SUBSTRUCTURES:
BURIED UTILITIES ARE SHOWN AS INDICATED ON RECORDS MAPS FURNISHED
BY OTHERS AND VERIFIED WHERE POSSIBLE BY FEATURES LOCATED IN THE
FIELD. WE ASSUME NO LIABILITY FOR THE ACCURACY OF THOSE RECORDS.
FOR THE FINAL LOCATION OF EXISTING UTILITIES IN AREAS CRITICAL TO
DESIGN CONTACT THE UTILITY OWNER/AGENCY.
TELECOMMUNICATIONS/FIBER OPTIC DISCLAIMER:
RECORDS OF UNDERGROUND TELECOMMUNICATIONS AND/OR FIBER OPTIC
LINES ARE NOT ALWAYS AVAILABLE TO THE PUBLIC. BRH HAS NOT
CONTACTED EACH OF THE MANY COMPANIES, IN THE COURSE OF THIS
SURVEY, WHICH COULD HAVE UNDERGROUND LINES WITHIN ADJACENT
RIGHTS—OF—WAY. THEREFORE, BRH DOES NOT ACCEPT RESPONSIBILITY FOR
THE EXISTENCE OF UNDERGROUND TELECOMMUNICATIONS/FIBER OPTIC LINES
WHICH ARE NOT MADE PUBLIC RECORD WITH THE LOCAL JURISDICTION. AS
ALWAYS, CALL 1-800-424-5555 BEFORE CONSTRUCTION.
UTILITY PROVIDERS:
POWER AND NATURAL GAS
PUGET SOUND ENERGY
355 110TH AVENUE NE
BELLEVUE, WA 98004
(206) 425-2000
(888) 225-5773
NATURAL GAS:
PUGET SOUND ENERGY
10885 NE 4TH STREET, SUITE 1200
PO BOX 97034
BELLEVUE, WA 98009-9734
(425) 454-6363
(888) 225-5773
TELEPHONE:
CENTURY LINK
1600 7TH AVENUE
SEATTLE, WA 98191
(800) 244-1111
CITY OF RENTON CONTACTS:
ABDOUL GAFOUR
CITY OF RENTON WATER UTILITY SUPERVISOR
1055 SOUTH GRADY WAY
RENTON, WA 98057
(425) 430-7210
ANDREW WEYGANDT
CITY OF RENTON PROJECT MANAGER
1055 SOUTH GRADY WAY
RENTON, WA 98057
(425) 430-7208
RAYMOND SLED
CITY OF RENTON WATER MAINTENANCE SHOP SUPERVISOR
3555 NE 2ND STREET
RENTON, WA 98056
(425)430-7400
GENERAL NOTES
1. ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE LATEST STANDARDS
AND SPECIFICATIONS OF THE CITY OF RENTON PUBLIC WORKS DEPARTMENT AND
THE 2008 EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS
APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD
PLANS & SPECIFICATIONS. SOME STANDARD DETAIL DRAWINGS MAY HAVE BEEN
MODIFIED FOR THIS CONTRACT THE CONTRACTOR SHALL REFER TO DETAIL
DRAWINGS INCLUDED IN THE CONTRACT DOCUMENTS. A SET OF APPROVED
PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION.
2. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL
BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT
LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATES
CALL 800-424-5555 (OR 811) A MINIMUM OF 72 HOURS PRIOR TO EXCAVATION.
J. AN APPROVED TRAFFIC CONTROL PLAN IS REQUIRED TO BE SUBMITTED AT THE
PRE—CONSTRUCTION MEETING. ANY MODIFICATIONS TO THE APPROVED TRAFFIC
CONTROL PLAN SHALL BE RESUBMITTED AND APPROVED PRIOR TO
IMPLEMENTATION.
4. ALL NEW WATER PIPE AND FITTINGS SHALL HAVE A FOAM PIPE PIG RUN THROUGH
THEM BEFORE BEING FLUSHED, DISINFECTED, AND PRESSURE TESTED. THE
CONTRACTOR SHALL NOTIFY THE CITY OF RENTON WATER MAINTENANCE
DEPARTMENT TWO WEEKS BEFORE MAKING A CUT—IN CONNECTION TO AN EXISTING
WATER MAIN AND 5 DAYS BEFORE MAKING A CONNECTION TO A NEWLY CUT—IN
TEE AND VALVE(S) ON THE EXISTING MAIN. ALL PIPE AND FITTINGS NOT TO BE
DISINFECTED IN PLACE SHALL BE SWABBED WITH 1Z CHLORINE SOLUTION PRIOR
TO INSTALLATION.
5. AFTER DISINFECTING THE WATERMAIN, DISPOSE OF CHLORINATED WATER BY
DISCHARGING TO THE NEAREST OPERATING SANITARY SEWER.
6. DEFLECT THE WATERMAIN ABOVE OR BELOW EXISTING UTILITIES AS REQUIRED TO
MAINTAIN 3FT MINIMUM COVER, 12 IN. MINIMUM VERTICAL CLEARANCE BETWEEN
UTILITIES UNLESS OTHERWISE SPECIFIED.
7. ALL FITTINGS SHALL BE BLOCKED PER CITY OF RENTON STANDARD DETAILS
UNLESS OTHERWISE NOTED.
8. THE CONTRACTOR SHALL NOT LEAVE STOCKPILED TRENCH EXCAVATION MATERIAL
ON CITY STREETS OUTSIDE OF WORK HOURS.
9. THE CONTRACTOR SHALL USE A VACUUM STREET SWEEPER TO REMOVE DUST AND
DEBRIS FROM PAVEMENT AREA AS DIRECTED BY THE ENGINEER. FLUSHING OF
STREETS SHALL NOT BE PERMITTED.
10. BEFORE COMMENCEMENT OF TRENCHING, THE CONTRACTOR SHALL PROVIDE A
CATCH BASIN FILTER FOR ALL DOWNHILL STORM DRAIN INLETS AND CATCH
BASINS. THE CONTRACTOR SHALL PERIODICALLY INSPECT THE CONDITION OF ALL
FILTERS AND REPLACE AS NECESSARY.
11. PAVEMENT MARKINGS (E. G. LANE LINE BUTTONS OR PAINT, STOP BARS,
CROSSWALKS, ETC.) DAMMAGED OR REMOVED DURING CONSTRUCTION SHALL BE
REPLACED IN KIND.
12. TEMPORARY RESTORATION OF TRENCHES FOR OVERNIGHT USE SHALL BE
ACCOMPLISHED BY USING COLD MIX ASPHALT (HMA). STEEL PLATES MAY BE
USED OVERNIGHT TO COVER THE LAST SECTION OF TRENCH. STEEL PLATES
MUST BE PINNED DOWN AND ASPHALT RAMPS/WEDGES MUST BE PLACED AROUND
THE PLATES. STEEL PLATES SHALL NOT BE USED ON STEEP GRADES OR WHERE
STEEL PLATES PRESENT A ROADWAY HAZARD.
13. THE CONTRACTOR SHALL KEEP PROJECT AREA OPEN TO TRAFFIC AT ALL TIMES,
UNLESS APPROVED BY THE CITY OF RENTON.
14. CONSTRUCTION WORK SHALL BE FROM 8:00 AM TO 4:00 PM.
CHECKED FOR COMPLIANCE WITH CITY STANDARDS
By:---------------- Date: --------
By:---------------- Date: --------
By:---------------- Date: --------
By:---------------- Date: --------
By:
By:
By:
By:
AMERICAN SURVEYING & ENGINEERING, LLC (ASE)
CONDUCTED AN AS—BUILT SURVEY TO LOCATE ALL WATER
VALVES, HYDRANTS AND WATER SERVICE METERS. AS—BUILT
DRAWING REDLINE MARKUPS WERE MAINTAINED BY THE
BUNO CONSTRUCTON COMPANY ON SITE CONSTRUCTION
FOREMAN AND PROVIDED TO ASE TO PREPARE THE FINAL
RECORD DRAWINGS. THE RECORD DRAWINGS REFLECT THE
AS—CONSTRUCTED CONDITIONS BASED ON A COMBINATION
OF FIELD SURVEY DATA AND THE AS—BUILT REDLINE
MARKUP DRAWINGS PROVIDED FROM BUNO CONSTRUCTION
AND SHOULD BE FIELD VERIFIED FOR ANY FUTURE USE. ALL
WATER VALVES, HYDRANTS AND WATER SERVICE METERS
WERE FIELD SURVEYED IN THEIR AS—BUILT LOCATIONS AND
A C C U R A T EL Y R E F L E C T E D H E R E O N.
RECOMMENDED FOR APPROVAL
-------------- Date:---.
-------------- Date:---
-------------- Date:---.
-------------- Date: ---
CITY OF