HomeMy WebLinkAboutP_FIRE SPRINKLER PLAN_CRUMBL COOKIES_20240624_v1DC1ORDER/PICKUPOPENBAKERYBACK OFHOUSERESTROOM4MAIN4MAIN4(E)
M
A
I
N OVENOVENRACKSFREEZER1½" X1" MT10-21½" X1" MT
1½
(E)
B
L
1½
(E)
B
L
1½(E) BL 1½(E) BL 1½(E) BL1½" X1" MT1½" X1" MT1½" X1
"
MT1½" X1"
MT
1½
(E)
B
L 1½"
X1"
MTCLG:12-0CLG:12-0CLG:12-0CLG:8-01½" X1" MT16-7 AFFSTEEL BAR JOIST24" DEEPSTEEL BAR JOIST24" DEEPSTEEL BAR JOIST24" DEEP17-6 AFF16-3 AFF17-2 AFF15-10 AFF17-0 AFF16-7 AFF15-5 AFF15-8 AFF16-0 AFFDWN 1"4-0 DWN 1"4-0 DWN 1"3-8DWN 1"3-8DWN 1"3-8DWN 1"3-3DWN 1
"2-010-210-2ADWN 1"2-41½" X1
"
MTDWN 1"3-6
1½" X1" MT 10-2*10-210-211-010-2DWN 1"7-1**10-210-2AREA OF WORKAREA OF WORKNEW 1" DROPEXISTING 1½" BRANCH LINEM
TBAKERYCLG:12-0BATHROOMCLG:8-0STEEL BAR JOISTNEW FLEX DROPNEW PENDENTUNOUNLESS NOTED OTHERWISENASNO AUTO. SPRINKLERSOFOWOUTSIDE FACE OF WALLIFOWINSIDE FACE OF WALLFOFIELD ORDERCTSCUT TO SUITBOTBOTTOM OF TRUSSBOPBOTTOM OF PURLINBOJBOTTOM OF JOISTBODBOTTOM OF DECKBOBBOTTOM OF BEAMABOVE FINISHED FLOORAFFQTYSPRINKLER SYMBOLSTEMPORIFICETHREADK-FAC.FINISHTYPESIN#MAKESYMTOTAL SPRINKLERS THIS SHEET10WATERFLOW INFORMATIONSTATICRESIDUALGPM FLOWINGDATE & TIMEPER:NOTES:ABBREVIATIONSRIGID COUPLINGFLEXIBLE COUPLINGFLOCATION:7855 S 206TH STREET, KENT, WA 98032FIRE SPRINKLER DIVISIONPHONE 253-872-7222 FAX 253-872-7277BYDESCRIPTIONREVISIONS-DATE-HYDRAULIC DESIGN INFORMATIONSHORT STRAPU-HOOKCEILING FLANGECOACH SCREW RODSAMMY SUPERSCREWSAMMY SIDEWINDERHDI-PKWIK-BOLTNUT & PLATE WASHEREYE SOCKETSIDE BEAM BRACKETABEAM CLAMP W/ RETAINING STRAPHANGERSWALL BRACKETBCDEFGHJKLMNTRAPEZEPREV:QR3. UNDERGROUND PIPING OF ANY TYPE5. LABELING, PREP FOR & PRIMING OR PAINTING OF ANY TYPE.4. STRUCTURAL VERIFICATION & ABATEMENT OF ANY TYPE.2. ELECTRICAL OF ANY TYPE.1. TAXES OF ANY TYPE.EXCLUSIONS:3. MATERIALS PER NFPA #13 (2019) STANDARDS AS SELECTED BY ARCHER CONSTRUCTION, INC.4. TESTING PER NFPA #13 (2019) & CITY OF RENTON.1. ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED AT A MINIMUM OF 40°FCLARIFICATIONS:(BY OTHERS) IN ORDER TO PREVENT THE PIPE FROM FREEZING.DESIGN CRITERIA:1. CRITERIA BASED ON NFPA #13 (2019) AND CITY OF RENTON CODES.FITTER NOTES:1. HANGERS:6. RELOCATION OF PIPE FOR WORK OF OTHER TRADES.5. NEW CEILING AND WALLS DO NOT AFFECT EXISTING UPRIGHT SPRINKLER PROTECTION.FIRE SPRINKLER TI PIPING PLANSCALE: 1/4" = 1'-0"HYDRAULIC DESIGN INFORMATIONFP 1 OF 1PERMIT NO:FIRE SPRINKLERPIPING PLAN / / / / JOB NO:AUTHORITY:DESIGNER:SCALE:DATE:NOTEDREVISEDPLOTTEDCONTACT:CONTRACTOR:PHONE:S24-052CITY OF RENTONRICHARD M06/18/2024XX PSIXX PSIXXXX GPMXX/XX/XXXXAREA NUMBER:CODE:HAZARD:SYSTEM TYPE: AREA PER SPRINKLER:REMOTE AREA SQ. FT.:TOTAL SYSTEM REQUIREMENTS:DENSITY GPM/SQ. FT.:NUMBER OF SPRINKLERS:OUTSIDE HOSE ALLOWANCE:AREA NUMBER:CODE:HAZARD:SYSTEM TYPE: AREA PER SPRINKLER:REMOTE AREA SQ. FT.:TOTAL SYSTEM REQUIREMENTS:DENSITY GPM/SQ. FT.:OUTSIDE HOSE ALLOWANCE:XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX2. DESIGN CRITERIA: - (E) CRITERIA - WAREHOUSE: ESFR SPACING 10' X 10'.- NEW CRITERIA - BAKERY: OH1 - 130 SQ.FT. , E.C. PENDENT HEADS - 20' X 20' MAX SPACING.3. NEW DESIGN CRITERIA IS LESS THAN EXISTING THUS NEW HYDRAULIC CALCULATIONS ARE NOT PROVIDED.4. ALL SPRINKLER DROPS INTO ACOUSTICAL TILE CEILING TO BE INSTALLED QUARTER POINT OF CEILING TILE. 5. ALL NEW PENDENT SPRINKLERS ADDED BY MECHANICAL TEE ON (E) BRANCH LINE.6. ALL NEW PENDENT HEADS ARE INSTALL WITH AH2 FLEX DROP.4. TENANT IMPROVEMENT AREA: 5. OWNER: CPT THE LANDING LLC- FLOOR: 1.510 SQ FT1. PARCEL #: 886600040BUILDING INFO: - 955 PARK AVE N, RENTON, WA. 98057NUMBER OF SPRINKLERS:CAMERON ROUNDSB.A.R. CONTRACTING435-668-7988CRUMBL COOKIES #1077815 N 10TH PL.RENTON, WA. 980572. CONSTRUCTION TYPE: II-B3. OCCUPANCY TYPE: BWALL LEGEND: VICINITY MAPSCALE: N.T.S.SITE PLANSCALE: N.T.S.= NEW WALL (PARTITION WALL)= EXISTING WALLSPRINKLER LEGEND: = HANGER= 48" AH2 FLEX DROPXX= HYDRAULIC NODE = SWAY BRACE= MECHANICAL TEEMT= RELOCATED SPRINKLER= ADDED SPRINKLER= PLUG SPRINKLERARPLUG= 72" AH2 FLEX DROP*1. ADD REQUIRED SPRINKLERS FOR NEW CEILING & WALL LOCATIONS.SCOPE OF WORK:2. PLAN SUBMITTAL TO & APPROVAL BY CITY OF RENTON. = (E) SPRINKLER PIPE= NEW SPRINKLER PIPE2. ALL THREADED PIPING TO BE SCHD 40 THREAD JOINED W/ THREADED FITTINGS.3. ALL GROOVED PIPE TO BE SCH. 10, JOINED GROOVED FITTINGS AND COUPLINGS.SCALE: 1/4" = 1'-0"-5051020EXISTING ESFR UPRIGHTSECTION VIEW ASCALE: N.T.S.* NO HANGERS REQUIRED.RELIABLERA7216E.C. PENDENTCHROMEK=11.23/4"5/8"155°8RELIABLERA1414RECESSED PENDENTCHROMEK=5.6½"½"155°1Michael MaguireRELIABLERA7216E.C. PENDENTCHROMEK=11.23/4"5/8"286°1