Loading...
HomeMy WebLinkAboutPN_TUP_Project_Narrative_170418_v1 April 18, 2017 DRS Project No. 16041 Clark H. Close Senior Planner 1055 South Grady Way Renton, WA 98057 Re: Cedars at the Highlands TUP Project Narrative This narrative is provided in support of the Tier 2 Temporary Use permit (TUP) submittal for Cedars at the Highlands. A 5-year TUP is requested for the existing structures that will be occupying two of the lots within the proposed subdivision. The existing structures will specifically be on Lots 9 and 10. The Site is located at 14120 160th Avenue SE in Renton, Washington, also known as King County Tax Parcel Number 145750-0110. The project is the subdivision of the existing parcel into 14 single-family residential lots. The Site area is 195,531 s.f. (4.49 acres). As stated above, the existing structures will be retained under a 5-year temporary use permit (TUP) and occupy two of the proposed 14 lots. After 5 years, the existing structures will be demolished and replaced with single-family residences. Project Contact Information: Developer: Harbour Homes, LLC 400 N 34th Street, Suite 300 Seattle, WA 98103 (206) 315-8130 Jamie Waltier Engineer/Surveyor: D.R. Strong Consulting Engineers 620 7th Avenue Kirkland, WA 98033 (425) 827-3063 Yoshio Piediscalzi, P.E. Land Use Permits Required: -Preliminary Plat Approval -Grading Permit -Final Plat Approval -Building Permit(s) -Environmental Review Zoning and Density: The property and adjacent properties are zoned R-4. Clark H. Close April 18, 2017 Page 2 of 3 Current use of Site and existing improvements: The current site contains an existing workshop, shed, and associated driveways. The site also contains a Type Ns stream in the northeast corner. The remainder of the site is forested with thick underbrush. Special Site features: There is a Type Ns stream that runs through the northeast corner of the site. Soil Type and Drainage Conditions: As per the King County Soil Survey, onsite soil consists of AgC, Alderwood gravelly sandy loam with slopes ranging from 8-15%. The Site contains two Natural Discharge Areas (NDA), but is contained within one Threshold Discharge Area. The first NDA is the northeast cor ner of the Site. Surface runoff from this NDA sheet flows to the existing Type Ns stream. The second NDA is located at the southeast corner of the Site and runoff sheet flows to an existing swale located in 162nd Avenue NE. These two downstream paths converge within ¼ mile of the Site. Proposed Use of Property: The Project is the subdivision of one existing parcel zoned R-4 (4.49 ac. Total, 3.83 ac. Net) into 14 single-family residential lots, per the City of Renton’s subdivision process. This will result in a density of 3.66 dwelling units per acre. Lot square footages range from 9,002 s.f. to 16,821 s.f., with no lot sizes below the minimum 9,000 s.f. threshold set by the City. The Project is requesting a 5-year TUP for the existing structures. These existing structures will be located in two of the lots within the new subdivision. Access, Traffic, and Circulation: The project will locate its internal residential road as depicted on the preliminary plat plan. Access to the subdivision will be from 160th Avenue SE via a 53’ right-of-way. A cul-de-sac will be provided near the eastern end of the property. No lots will be allowed to access off of 162 nd Avenue SE. Proposed Off-site Improvements: Frontage improvements along 160th Avenue SE will be installed. The existing 4” water main in 160th Avenue SE is proposed to be replaced with an 8” line. No frontage improvements area proposed for 162nd Avenue SE. Estimated Construction Cost & Proposed Market Value: The approximate construction cost is typical of a subdivision of this size and nature totals approximately $600,000.00. The estimated fair market value of the proposed project is approximately $4,000,000.00. Clark H. Close April 18, 2017 Page 3 of 3 Cut Materials: Approximately 4,450 c.y. of cut and 7,716 c.y. of fill is computed for the Project. The net volume is approximately 5936 c.y. of fill. Fill needed in excess of onsite soil will be imported from an approved source and will be approved by the geotechnical engineer. Tree Inventory: Tree retention shall comply with a minimum of at least thirty (30%) of significant tress retained according to priority established in RMC 4-4-130. If 30% tree retention cannot be met, additional trees will be planted to meet the City’s tree retention requirements per Renton Municipal Code section 4-4-130 Tree Retention and Land Clearing Regulations. 41 of the existing 284 significant trees will be retained onsite. 43 trees are within proposed right of way, 69 trees are dangerous, and 10 trees are located in critical areas and buffers. This equates to 49 trees required to be retained; see tree retention spreadsheet. 96 replacement inches will be provided to account for tree retention requirements. Land Dedication: Approximately 28,777 s.f. (0.661 acres) will be dedicated to the city as public right-of-way residential street for access to the subdivision. Job Shacks: A job shack is expected to be located on the Site during the construction phase of the development. Location and placement of shack/construction materials will be further discussed at the time of final engineering. Proposed Modifications: A waiver request for the half-street frontage improvements along 162nd Avenue SE has been applied for with the preliminary subdivision submittal due to the existing stream. Distance to Existing Stream The current proposed undisturbed Sensitive Area Tract (Tract B) includes a 50’ buffer from the high-water mark of the unnamed Type Ns Stream. Sincerely yours, D. R. STRONG Consulting Engineers Inc. Yoshio Piediscalzi, P.E. Project Engineer YLP R:\2016\0\16041\3\Documents\Reports\Preliminary\TUP Project Narrative 16041.doc