Loading...
HomeMy WebLinkAboutP_Erosion_Control_and_Storm_Drainage_Plans_240513_v1.pdfMPH15TAXIWAY ARUNWAY 16-34TAX I W A Y A 7 30 2831 312927 262929SWSW S W SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW SWSWSWSWSWSW(TYP.)1(TYP.)2PAVEMENT LIMITS, TYP.SCALES ACCORDINGLY.THIS SHEET, ADJUSTIF NOT ONE INCH ON 0" 1"ORIGINAL DRAWING.BAR IS ONE INCH ONVERIFY SCALESAPPRBYNO.DATEREVISIONSSHEET NO.DRAWING NO.DATE:PROJECT NO:SCALE:CHECKED BY:DRAWN BY:DESIGNED BY:PRELIMINARYNOT FOR CONSTRUCTIONR 60% DESIGNMBXRENTON MUNICIPAL AIRPORTTAXIWAY A RECONSTRUCTION/REHABILITATIONAND ASSOCIATED IMPROVEMENTSPlotted By:Stanek, Michael Sheet Set:############################################################################################### Layout:C5.1 April 11, 2024 09:25:45am K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C5.0 - EROSION CONTROL.dwg © 2024 KIMLEY-HORN AND ASSOCIATES, INC.WWW.KIMLEY-HORN.COM PHONE: 206-607-26001201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101LIC PROF 1WASHINGTON LICENSE NUMBERLIC PROF 1 #____------------APRIL 202435022.008.021" = 40'DSWCEFCTHEROSION CONTROL PLAN 1 OF 5C5.121 OF 71MATCHLINE STA. 11+50 SEE SHEET C5.2STORM DRAIN CATCH BASIN INSERT PER DETAIL 1, SHEETC5.61INSTALL STRAW WATTLE PER DETAIL 2, SHEET C5.62EXISTING STORM PIPERUNWAY SAFETY AREARUNWAY OBJECT FREE ZONETAXIWAY SAFETY AREATAXIWAY OBJECT FREE AREAPROPOSED STRAW WATTLEPROPOSED CATCH BASIN INSERTEXISTING STORM INLETSWRSAROFZTOFATSASDEROSION CONTROL NOTESLEGENDN0SCALE 1" = 408040 AHEADLANEONEAHEADLANEONE AHEADLANEONETAXIWAY ATA X I W A Y A 6RUNWAY 16-342525 25 24 24 25252627 28S W S W S W S W SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW(TYP.)1(TYP.)2PAVEMENT LIMITS, TYP.CONSTRUCTIONPHASE 2CONSTRUCTIONPHASE 1SCALES ACCORDINGLY.THIS SHEET, ADJUSTIF NOT ONE INCH ON 0" 1"ORIGINAL DRAWING.BAR IS ONE INCH ONVERIFY SCALESAPPRBYNO.DATEREVISIONSSHEET NO.DRAWING NO.DATE:PROJECT NO:SCALE:CHECKED BY:DRAWN BY:DESIGNED BY:PRELIMINARYNOT FOR CONSTRUCTIONR 60% DESIGNMBXRENTON MUNICIPAL AIRPORTTAXIWAY A RECONSTRUCTION/REHABILITATIONAND ASSOCIATED IMPROVEMENTSPlotted By:Stanek, Michael Sheet Set:############################################################################################### Layout:C5.2 April 11, 2024 09:25:46am K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C5.0 - EROSION CONTROL.dwg © 2024 KIMLEY-HORN AND ASSOCIATES, INC.WWW.KIMLEY-HORN.COM PHONE: 206-607-26001201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101LIC PROF 1WASHINGTON LICENSE NUMBERLIC PROF 1 #____------------APRIL 202435022.008.021" = 40'DSWCEFCTHEROSION CONTROL PLAN 2 OF 5C5.222 OF 71MATCHLINE STA. 11+50 SEE SHEET C5.1 MATCHLINE STA. 23+50 SEE SHEET C5.3STORM DRAIN CATCH BASIN INSERT PER DETAIL 1, SHEETC5.61INSTALL STRAW WATTLE PER DETAIL 2, SHEET C5.62EXISTING STORM PIPERUNWAY SAFETY AREARUNWAY OBJECT FREE ZONETAXIWAY SAFETY AREATAXIWAY OBJECT FREE AREAPROPOSED STRAW WATTLEPROPOSED CATCH BASIN INSERTEXISTING STORM INLETSWRSAROFZTOFATSASDEROSION CONTROL NOTESLEGENDN0SCALE 1" = 408040 AHEADLANE ONE MPH15 MPH15RUNWAY 16-34TAXIWAY A4TAXIWAY A5 TAXIWAY A25252525252523 2326SWSWSWSWSWSWSWSWSW SW SW SWSWSWSWSWSWSWSWSWSWSWSW SW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW(TYP.)2(TYP.)1PAVEMENT LIMITS, TYP.SCALES ACCORDINGLY.THIS SHEET, ADJUSTIF NOT ONE INCH ON 0" 1"ORIGINAL DRAWING.BAR IS ONE INCH ONVERIFY SCALESAPPRBYNO.DATEREVISIONSSHEET NO.DRAWING NO.DATE:PROJECT NO:SCALE:CHECKED BY:DRAWN BY:DESIGNED BY:PRELIMINARYNOT FOR CONSTRUCTIONR 60% DESIGNMBXRENTON MUNICIPAL AIRPORTTAXIWAY A RECONSTRUCTION/REHABILITATIONAND ASSOCIATED IMPROVEMENTSPlotted By:Stanek, Michael Sheet Set:############################################################################################### Layout:C5.3 April 11, 2024 09:25:51am K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C5.0 - EROSION CONTROL.dwg © 2024 KIMLEY-HORN AND ASSOCIATES, INC.WWW.KIMLEY-HORN.COM PHONE: 206-607-26001201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101LIC PROF 1WASHINGTON LICENSE NUMBERLIC PROF 1 #____------------APRIL 202435022.008.021" = 40'DSWCEFCTHEROSION CONTROL PLAN 3 OF 5C5.323 OF 71MATCHLINE STA. 23+50 SEE SHEET C5.2 MATCHLINE STA. 35+50 SEE SHEET C6.4STORM DRAIN CATCH BASIN INSERT PER DETAIL 1, SHEETC5.61INSTALL STRAW WATTLE PER DETAIL 2, SHEET C5.62EXISTING STORM PIPERUNWAY SAFETY AREARUNWAY OBJECT FREE ZONETAXIWAY SAFETY AREATAXIWAY OBJECT FREE AREAPROPOSED STRAW WATTLEPROPOSED CATCH BASIN INSERTEXISTING STORM INLETSWRSAROFZTOFATSASDEROSION CONTROL NOTESLEGENDN0SCALE 1" = 408040 MPH15 MPH15TAXIWAY ARUNWAY 16-34TAXIWAY A325202324242422212323242424(TYP.)1SWSWSWSWSWSWSWSWSW SW SWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSWSW(TYP.)2PAVEMENT LIMITS, TYP.SCALES ACCORDINGLY.THIS SHEET, ADJUSTIF NOT ONE INCH ON 0" 1"ORIGINAL DRAWING.BAR IS ONE INCH ONVERIFY SCALESAPPRBYNO.DATEREVISIONSSHEET NO.DRAWING NO.DATE:PROJECT NO:SCALE:CHECKED BY:DRAWN BY:DESIGNED BY:PRELIMINARYNOT FOR CONSTRUCTIONR 60% DESIGNMBXKEYPLANRENTON MUNICIPAL AIRPORTTAXIWAY A RECONSTRUCTION/REHABILITATIONAND ASSOCIATED IMPROVEMENTSPlotted By:Stanek, Michael Sheet Set:############################################################################################### Layout:C5.4 April 11, 2024 09:25:56am K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C5.0 - EROSION CONTROL.dwg © 2024 KIMLEY-HORN AND ASSOCIATES, INC.WWW.KIMLEY-HORN.COM PHONE: 206-607-26001201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101LIC PROF 1WASHINGTON LICENSE NUMBERLIC PROF 1 #____------------APRIL 202435022.008.021" = 40'DSWCEFCTHEROSION CONTROL PLAN 4 OF 5C5.424 OF 71MATCHLINE STA. 35+50 SEE SHEET C5.3 MATCHLINE STA. 47+50 SEE SHEET C5.5STORM DRAIN CATCH BASIN INSERT PER DETAIL 1, SHEETC5.61INSTALL STRAW WATTLE PER DETAIL 2, SHEET C5.62EXISTING STORM PIPERUNWAY SAFETY AREARUNWAY OBJECT FREE ZONETAXIWAY SAFETY AREATAXIWAY OBJECT FREE AREAPROPOSED STRAW WATTLEPROPOSED CATCH BASIN INSERTEXISTING STORM INLETSWRSAROFZTOFATSASDEROSION CONTROL NOTESLEGENDN0SCALE 1" = 408040 (TYP.)MPH15MPH15 TAXIWAY ARUNWAY 16-3420232221 212222242423222122232321 22 23242526SWSWSWSWSWSWSW SWSWSWSWSWSWSW SW SWSWSWSWSWSWSWSWTAXIWAY A1 TAXIWAY A22 (TYP.)1PAVEMENT LIMITS, TYP.PAVEMENT LIMITS, TYP.SWSWSWSW(TYP.)2SCALES ACCORDINGLY.THIS SHEET, ADJUSTIF NOT ONE INCH ON 0" 1"ORIGINAL DRAWING.BAR IS ONE INCH ONVERIFY SCALESAPPRBYNO.DATEREVISIONSSHEET NO.DRAWING NO.DATE:PROJECT NO:SCALE:CHECKED BY:DRAWN BY:DESIGNED BY:PRELIMINARYNOT FOR CONSTRUCTIONR 60% DESIGNMBXKEYPLANRENTON MUNICIPAL AIRPORTTAXIWAY A RECONSTRUCTION/REHABILITATIONAND ASSOCIATED IMPROVEMENTSPlotted By:Stanek, Michael Sheet Set:############################################################################################### Layout:C5.5 April 12, 2024 07:24:28am K:\SEA_Civil\SEA_PUBLIC\090119000.3 - Renton Airport - Taxiway A\08 CADD\PlanSheets\C5.0 - EROSION CONTROL.dwg © 2024 KIMLEY-HORN AND ASSOCIATES, INC.WWW.KIMLEY-HORN.COM PHONE: 206-607-26001201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101LIC PROF 1WASHINGTON LICENSE NUMBERLIC PROF 1 #____------------APRIL 202435022.008.021" = 40'DSWCEFCTHEROSION CONTROL PLAN 5 OF 5C5.525 OF 71MATCHLINE STA. 47+50 SEE SHEET C5.4STORM DRAIN CATCH BASIN INSERT PER DETAIL 1, SHEETC5.61INSTALL STRAW WATTLE PER DETAIL 2, SHEET C5.62EXISTING STORM PIPERUNWAY SAFETY AREARUNWAY OBJECT FREE ZONETAXIWAY SAFETY AREATAXIWAY OBJECT FREE AREAPROPOSED STRAW WATTLEPROPOSED CATCH BASIN INSERTEXISTING STORM INLETSWRSAROFZTOFATSASDEROSION CONTROL NOTESLEGENDN0SCALE 1" = 408040 SCALES ACCORDINGLY.THIS SHEET, ADJUSTIF NOT ONE INCH ON 0" 1"ORIGINAL DRAWING.BAR IS ONE INCH ONVERIFY SCALESAPPRBYNO.DATEREVISIONSSHEET NO.DRAWING NO.DATE:PROJECT NO:SCALE:CHECKED BY:DRAWN BY:DESIGNED BY:PRELIMINARYNOT FOR CONSTRUCTIONR 60% DESIGNRENTON MUNICIPAL AIRPORTTAXIWAY A RECONSTRUCTION/REHABILITATIONAND ASSOCIATED IMPROVEMENTSPlotted By:Stanek, Michael Sheet Set:############################################################################################### Layout:DTLS-1 April 11, 2024 09:26:10am K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C5.0 - EROSION CONTROL-DTLS-090119000.dwg © 2024 KIMLEY-HORN AND ASSOCIATES, INC.WWW.KIMLEY-HORN.COM PHONE: 206-607-26001201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101------------APRIL 202435022.008.021" = 40'DSWCEFCTHEROSION CONTROL DETAILS - 1C5.626 OF 711CATCH BASIN INSERT2STRAW WATTLES ------------MAY 202435022.008.021" = 40'DSWCEFCTHSTORM DRAINAGE GENERAL NOTESC6.027 OF 821.BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE- CONSTRUCTIONMEETING SHALL BE HELD AMONG THE CITY OF RENTON, HEREBY REFERRED TO AS THE CITY,THE APPLICANT, AND THE APPLICANT' S CONTRACTOR.2.THE APPLICANT SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY CITY, STATE, ANDFEDERAL PERMITS PRIOR TO CONSTRUCTION.3.ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED INACCORDANCE WITH THE LATEST EDITION OF THE CITY OF RENTON SURFACE WATER DESIGNMANUAL ( RENTON SWDM), RENTON MUNICIPAL CODE ( RMC), AND THE STANDARDSPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOTAND THE AMERICAN PUBLIC WORKS ASSOCIATION ( APWA). IT SHALL BE THE SOLERESPONSIBILITY OF THE APPLICANT TOCORRECT ANY ERROR, OMISSION OR VARIATIONFROM THE ABOVE REQUIREMENTS FOUND IN THE PLANS. ALL CORRECTIONS SHALL BE ATNO ADDITIONAL COST TO THE CITY.4.APPROVAL OF THE ROAD, GRADING, PARKING, BUILDING, AND DRAINAGE PLAN DOES NOTCONSTITUTE AS APPROVAL OF ANY OTHER CONSTRUCTION ( E.G. WATER,SEWER, GAS,ELECTRICAL. ETC.). PLANS FOR STRUCTURES SUCH AS BRIDGES, VAULTS, AND RETAININGWALLS REQUIRE A SEPARATE REVIEW AND APPROVAL BY THE CITY PRIOR TOCONSTRUCTION. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTEDACCORDING TO THE APPROVED PLANS. ANY DEVIATION FROM THE APPROVED PLANS WILLREQUIRE COORDINATION FOLLOWED BY WRITTEN APPROVAL FROM THE CITY.5.A COPY OF THE APPROVED PLANS SHALL BE ON THE JOB SITE WHENEVER CONSTRUCTION ISIN PROGRESS.6.THE LOCATIONS OF ALL EXISTING UTILITIES SHOWN HEREON HAVE BEEN ESTABLISHED BYFIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHALL THEREFORE BECONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLERESPONSIBILITY OF THE APPLICANT AND THE APPLICANT' S CONTRACTOR TOINDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN, AND TOFURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HEREON THAT MAY BEAFFECTED BY THE IMPLEMENTATION OF THIS PLAN. THE APPLICANT SHALL RECORD ON THEAS- BUILT DRAWINGS ALL UNDOCUMENTED UTILITIES DISCOVERED AND ANY CHANGES TOTHE APPROVED PLANS. THE APPLICANT SHALL IMMEDIATELY NOTIFY THE ENGINEER OFRECORD IF A CONFLICT EXISTS.7.VERTICAL DATUM SHALL BE NAVD 88 AND HORIZONTAL DATUM SHALL BE NAD 83 ( WA STATEPLANE, NORTH), UNLESS OTHERWISE APPROVED BY THE CITY. REFERENCE BENCHMARK,DATUM, AND ELEVATIONS SHALL BE NOTED ON THE PLANS.8.ALL UTILITY TRENCH BACKFILL AND ROADWAY SUBGRADE SHALL BE COMPACTED TO 95%MAXIMUM DRY DENSITY PER SECTION 2-03.3(14)D - COMPACTION AND MOISTURE CONTROLTESTS OF THE WSDOT STANDARD SPECIFICATIONS.9.OPEN CUTTING OF EXISTING ROADWAYS FOR STORM DRAINAGE WORK IS NOT ALLOWEDUNLESS SPECIFICALLY APPROVED BY THE CITY AND NOTED ON THESE APPROVED PLANS.ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY TRENCH RESTORATIONSTANDARDS.10.ALL PIPE AND STRUCTURES SHALL BE STAKED FOR SURVEY LINE AND GRADE PRIOR TO THESTART OF CONSTRUCTION. WHERE SHOWN ON THE PLANS OR WHERE DIRECTED BY THECITY, THE EXISTING MANHOLES, CATCH BASINS, OR INLETS SHALL BE ADJUSTED TO THEGRADE AS STAKED.11.NOT USED.12.ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION INACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FORROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THETRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT ANDCOMPACTION OF REQUIRED BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRELENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALLPIPE BEDDING AND BACKFILL SHALL BE AS SHOWN ON THE CITY STANDARD PLAN 220. 00,220.10, AND 20.13.NOT USED.14.ALL DRAINAGE STRUCTURES SUCH AS CATCH BASINS AND MANHOLES SHALL BE FITTED WITHDUCTILE IRON, BOLT- LOCKING LIDS AS SHOWN ON THE PLANS. STRUCTURES SHALL HAVEROUND, SOLID LIDS DISPLAYING THE CITY LOGO WHEN ON THE AIRPORT. PRIVATESTRUCTURE LIDS OUTSIDE PUBLIC AIRFIELD AND EASEMENTS TO THE CITY SHALL NOTDISPLAY THE CITY LOGO.15.NOT USED.16.LIDS OF MANHOLES/ CATCH BASINS WITHIN PUBLIC RIGHT- OF- WAY SHALL NOT BE ADJUSTEDTO FINAL GRADE UNTIL AFTER PAVING. ALL MANHOLE/ CATCH BASIN RIMSSHALL BEADJUSTED TO BE FLUSH WITH FINAL FINISHED GRADES, UNLESS OTHERWISE SHOWN.17.NOT USED.18.ROCK FOR EROSION PROTECTION OF DITCHES, WHERE REQUIRED, SHALL BE OF SOUNDQUARRY ROCK PLACED TO A MINIMUM DEPTH OF ONE ( 1) FOOT AND SHALL MEET THEFOLLOWING SPECIFICATIONS:·4 - 8 INCH ROCK / 40 - 70% PASSING;·2 - 4 INCH ROCK / 30 - 40% PASSING; AND·LESS THAN 2 INCH ROCK / 10 - 20% PASSING.19.NOT USED.20.THE END OF EACH STORM DRAIN STUB SHALL BE CAPPED. A CLEANOUT TOPPED WITH ABOLT- LOCKING LID MARKED " STORM” OR " DRAIN" SHALL BE LOCATED AT T AT THE POINT OFCONNECTION OF A STORM DRAINAGE CONVEYANCE SYSTEM PER THE CITY STANDARD PLAN227. 00.21.ALL STORM SYSTEM EXTENSIONS SHALL BE STAKED FOR LINE AND GRADE BY A SURVEYORLICENSED IN WASHINGTON STATE, AND CUT SHEETS SHALL BE PROVIDED TO THE CITY PRIORTO CONSTRUCTION.22.ALL NEWLY- INSTALLED AND NEWLY- REHABILITATED ( PUBLIC AND PRIVATE) STORMCONVEYANCE SYSTEMS SHALL BE INSPECTED BY MEANS OF REMOTE CCTV ACCORDING TOTHE CITY STANDARD PLAN 266. 00. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTEDTO THE CITY PRIOR TO RECEIVING APPROVAL TO INSTALL PROJECT CURBS, GUTTERSAND/OR PAVEMENT.23.ALL STORM SYSTEMS AND CONNECTIONS TO EXISTING MAINS SHALL BE TESTED INACCORDANCE WITH SECTION 7-04.3(1) OF THE WSDOT STANDARD SPECIFICATIONS AND INTHE PRESENCE OF A REPRESENTATIVE OF THE CITY. STORM DRAIN STUBS SHALL BE TESTEDFOR ACCEPTANCE AT THE SAME TIME THE MAIN STORM IS TESTED.24.FOR ALL DISTURBED PERVIOUS AREAS ( COMPACTED, GRADED, LANDSCAPED, ETC.) OF THEDEVELOPMENT SITE, TO MAINTAIN THE MOISTURE CAPACITY OF THE SOIL EITHER STOCKPILEAND REDISTRIBUTE THE EXISTING DUFF LAYER AND NATIVE TOPSOIL OR AMEND THE SOILWITH COMPOST IN ACCORDANCE WITH STANDARD PLAN 264. 00.25.ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY DOES NOT RELIEVETHE APPLICANT OF THE CONTINUING LEGAL OBLIGATION AND/ OR LIABILITY CONNECTEDWITH STORMWATER DISPOSAL. THE CITY DOES NOT ACCEPT ANY OBLIGATION FOR THEPROPER FUNCTIONING AND MAINTENANCE OF THE STORM SYSTEM PROVIDED DURINGCONSTRUCTION.26.ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANYOTHER ACTIONS NEEDED TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, ANDTO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK SHALL BEPROVIDED. ANY WORK WITHIN THE AIRCARFT MOVEMENT AREA THAT MAY INTERRUPTNORMAL AIRCRAFT AND VEHICLE FLOW SHALL REQUIRE A TRAFFIC CONTROL PLANAPPROVED BY THE CITY. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-10TEMPORARY TRAFFIC CONTROL SHALL APPLY.27.NOT USED.28.NOT USED.29.NOT USED.30.MINIMUM COVER OVER STORM DRAINAGE PIPE SHALL CONFORM TO TABLE 4.2.1.A2 OF THERENTON SWDM.31.NOT USED.SURFACE WATER PLAN NOTESSCALES ACCORDINGLY.THIS SHEET, ADJUSTIF NOT ONE INCH ON 0" 1"ORIGINAL DRAWING.BAR IS ONE INCH ONVERIFY SCALESAPPRBYNO.DATEREVISIONSSHEET NO.DRAWING NO.DATE:PROJECT NO:SCALE:CHECKED BY:DRAWN BY:DESIGNED BY:PRELIMINARYNOT FOR CONSTRUCTIONR 90% DESIGNRENTON MUNICIPAL AIRPORTTAXIWAY A RECONSTRUCTION/REHABILITATIONAND ASSOCIATED IMPROVEMENTSPlotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:C6.0 May 13, 2024 02:24:09pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C6.0 - DRAINAGE SERIES.dwg © 2024 KIMLEY-HORN AND ASSOCIATES, INC.WWW.KIMLEY-HORN.COM PHONE: 206-607-26001201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101#################### LICENSE NUMBER################ MPH15SDSDSDSDSDCB TYPE 1AIRCRAFT RATEDRIM=26.23'IE 12" (SE)=24.87'IE 12" (N)=23.46'SUMP=24.46'TAXIWAY ARUNWAY 16-34T A X I W A Y A 7 37 LF37 LF127 LF146 LFSCALES ACCORDINGLY.THIS SHEET, ADJUSTIF NOT ONE INCH ON 0" 1"ORIGINAL DRAWING.BAR IS ONE INCH ONVERIFY SCALESAPPRBYNO.DATEREVISIONSSHEET NO.DRAWING NO.DATE:PROJECT NO:SCALE:CHECKED BY:DRAWN BY:DESIGNED BY:PRELIMINARYNOT FOR CONSTRUCTIONR 90% DESIGNRENTON MUNICIPAL AIRPORTTAXIWAY A RECONSTRUCTION/REHABILITATIONAND ASSOCIATED IMPROVEMENTSPlotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:C6.1 May 13, 2024 02:24:12pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C6.0 - DRAINAGE SERIES.dwg © 2024 KIMLEY-HORN AND ASSOCIATES, INC.WWW.KIMLEY-HORN.COM PHONE: 206-607-26001201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101#################### LICENSE NUMBER################EXISTING STORM PIPEEXISTING STORM INLETPROPOSED STORM PIPEPROPOSED STORM INLETSD------------MAY 202435022.008.021" = 40'GJRDMYDMYSTORM DRAINAGE IMPROVEMENTS PLAN 1 OF 5C6.128 OF 82MATCHLINE STA. 11+50 SEE SHEET C6.2REPLACE EXISTING STORM PIPEREPLACE EXISTING CATCH BASINREMOVE EXISTING STORM PIPEREMOVE EXISTING CATCH BASINSDINSTALL NEW AIRCRAFT RATED CATCH BASINREPLACE EXISTING CATCH BASIN GRATE WITH SOLIDLOCKING AIRCRAFT-RATED LIDSTORM DRAINAGE NOTESLEGENDN0SCALE 1" = 408040CONNECT TO EXISTING STRUCTURE AHEADLANEONEAHEADLANEONE AHEADLANEONESD SDSDSDCB TYPE 1AIRCRAFT RATEDRIM=23.71'IE 8" (SE)=21.97'IE 12" (NW)=21.76'TAXIWAY ATA X I W A Y A 6RUNWAY 16-34CONSTRUCTIONPHASE 2CONSTRUCTIONPHASE 1INSTALL 147 LF NEW 12" SD PIPESDCB TYPE 1AIRCRAFT RATEDRIM=24.35'IE 12" (S)=21.38'IE 12" (E)=21.38'SUMP=19.38INSTALL 44 LFNEW 12" SD PIPE138 LF236 LF129 LFSCALES ACCORDINGLY.THIS SHEET, ADJUSTIF NOT ONE INCH ON 0" 1"ORIGINAL DRAWING.BAR IS ONE INCH ONVERIFY SCALESAPPRBYNO.DATEREVISIONSSHEET NO.DRAWING NO.DATE:PROJECT NO:SCALE:CHECKED BY:DRAWN BY:DESIGNED BY:PRELIMINARYNOT FOR CONSTRUCTIONR 90% DESIGNRENTON MUNICIPAL AIRPORTTAXIWAY A RECONSTRUCTION/REHABILITATIONAND ASSOCIATED IMPROVEMENTSPlotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:C6.2 May 13, 2024 02:24:17pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C6.0 - DRAINAGE SERIES.dwg © 2024 KIMLEY-HORN AND ASSOCIATES, INC.WWW.KIMLEY-HORN.COM PHONE: 206-607-26001201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101#################### LICENSE NUMBER################------------MAY 202435022.008.021" = 40'GJRDMYDMYSTORM DRAINAGE IMPROVEMENTS PLAN 2 OF 5C6.229 OF 82MATCHLINE STA. 11+50 SEE SHEET C6.1 MATCHLINE STA. 23+50 SEE SHEET C6.3REPLACE EXISTING STORM PIPEREPLACE EXISTING CATCH BASINREMOVE EXISTING STORM PIPEREMOVE EXISTING CATCH BASININSTALL NEW CATCH BASINREPLACE EXISTING CATCH BASIN GRATE WITH SOLIDLOCKING AIRCRAFT-RATED LIDSTORM DRAINAGE NOTESN0SCALE 1" = 408040EXISTING STORM PIPEEXISTING STORM INLETPROPOSED STORM PIPEPROPOSED STORM INLETSDSDLEGENDCONNECT TO EXISTING STRUCTURE AHEADLANE ONE MPH15 MPH15SDSDSDCB TYPE 2AIRCRAFT RATEDRIM=25.82IE 12" (E)=TBDIE 12" (W)=TBDSUMP=TBDSDCB TYPE 2AIRCRAFT RATEDRIM=25.13IE 12" (E)=TBDIE 12" (W)=TBDSUMP=TBDRUNWAY 16-34TAXIWAY A4TAXIWAY A5 TAXIWAY A105 LF113 LF111 LF222 LFSCALES ACCORDINGLY.THIS SHEET, ADJUSTIF NOT ONE INCH ON 0" 1"ORIGINAL DRAWING.BAR IS ONE INCH ONVERIFY SCALESAPPRBYNO.DATEREVISIONSSHEET NO.DRAWING NO.DATE:PROJECT NO:SCALE:CHECKED BY:DRAWN BY:DESIGNED BY:PRELIMINARYNOT FOR CONSTRUCTIONR 90% DESIGNRENTON MUNICIPAL AIRPORTTAXIWAY A RECONSTRUCTION/REHABILITATIONAND ASSOCIATED IMPROVEMENTSPlotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:C6.3 May 13, 2024 02:24:22pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C6.0 - DRAINAGE SERIES.dwg © 2024 KIMLEY-HORN AND ASSOCIATES, INC.WWW.KIMLEY-HORN.COM PHONE: 206-607-26001201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101#################### LICENSE NUMBER################------------MAY 202435022.008.021" = 40'GJRDMYDMYSTORM DRAINAGE IMPROVEMENTS PLAN 3 OF 5C6.330 OF 82MATCHLINE STA. 23+50 SEE SHEET C6.2 MATCHLINE STA. 35+50 SEE SHEET C6.4REPLACE EXISTING STORM PIPEREPLACE EXISTING CATCH BASINREMOVE EXISTING STORM PIPEREMOVE EXISTING CATCH BASININSTALL NEW CATCH BASINREPLACE EXISTING CATCH BASIN GRATE WITH SOLIDLOCKING AIRCRAFT-RATED LIDSTORM DRAINAGE NOTESN0SCALE 1" = 408040EXISTING STORM PIPEEXISTING STORM INLETPROPOSED STORM PIPEPROPOSED STORM INLETSDSDLEGENDCONNECT TO EXISTING STRUCTURE MPH15 MPH15SD SDCB TYPE 2AIRCRAFT RATEDRIM=24.17IE 12" (E)=TBDIE 12" (W)=TBDSUMP=TBDTAXIWAY ARUNWAY 16-34TAXIWAY A3SDCB TYPE 1AIRCRAFT RATEDRIM=21.90'IE 12" (E)=20.60'IE 12" (S)=20.55'IE 12" (W)=20.50'93 LF166 LF176 LFSCALES ACCORDINGLY.THIS SHEET, ADJUSTIF NOT ONE INCH ON 0" 1"ORIGINAL DRAWING.BAR IS ONE INCH ONVERIFY SCALESAPPRBYNO.DATEREVISIONSSHEET NO.DRAWING NO.DATE:PROJECT NO:SCALE:CHECKED BY:DRAWN BY:DESIGNED BY:PRELIMINARYNOT FOR CONSTRUCTIONR 90% DESIGNRENTON MUNICIPAL AIRPORTTAXIWAY A RECONSTRUCTION/REHABILITATIONAND ASSOCIATED IMPROVEMENTSPlotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:C6.4 May 13, 2024 02:24:28pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C6.0 - DRAINAGE SERIES.dwg © 2024 KIMLEY-HORN AND ASSOCIATES, INC.WWW.KIMLEY-HORN.COM PHONE: 206-607-26001201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101#################### LICENSE NUMBER################------------MAY 202435022.008.021" = 40'GJRDMYDMYSTORM DRAINAGE IMPROVEMENTS PLAN 4 OF 5C6.431 OF 82MATCHLINE STA. 35+50 SEE SHEET C6.3 MATCHLINE STA. 47+50 SEE SHEET C6.5REPLACE EXISTING STORM PIPEREPLACE EXISTING CATCH BASINREMOVE EXISTING STORM PIPEREMOVE EXISTING CATCH BASININSTALL NEW CATCH BASINREPLACE EXISTING CATCH BASIN GRATE WITH SOLIDLOCKING AIRCRAFT-RATED LIDSTORM DRAINAGE NOTESN0SCALE 1" = 408040EXISTING STORM PIPEEXISTING STORM INLETPROPOSED STORM PIPEPROPOSED STORM INLETSDSDLEGENDCONNECT TO EXISTING STRUCTURE MPH15MPH15 SD SD SDCB TYPE 2AIRCRAFT RATEDRIM=22.52IE 12" (E)=TBDIE 12" (W)=TBDSUMP=TBDSDCB TYPE 2AIRCRAFT RATEDRIM=23.46IE 12" (E)=TBDIE 12" (W)=TBDSUMP=TBDSDCB TYPE 1AIRCRAFT RATEDRIM=20.96'IE 12" (SE)=19.26'SUMP=18.56'TAXIWAY A2 TAXIWAY ARUNWAY 16-34TAXIWAY A1195 LFSCALES ACCORDINGLY.THIS SHEET, ADJUSTIF NOT ONE INCH ON 0" 1"ORIGINAL DRAWING.BAR IS ONE INCH ONVERIFY SCALESAPPRBYNO.DATEREVISIONSSHEET NO.DRAWING NO.DATE:PROJECT NO:SCALE:CHECKED BY:DRAWN BY:DESIGNED BY:PRELIMINARYNOT FOR CONSTRUCTIONR 90% DESIGNRENTON MUNICIPAL AIRPORTTAXIWAY A RECONSTRUCTION/REHABILITATIONAND ASSOCIATED IMPROVEMENTSPlotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:C6.5 May 13, 2024 02:24:34pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C6.0 - DRAINAGE SERIES.dwg © 2024 KIMLEY-HORN AND ASSOCIATES, INC.WWW.KIMLEY-HORN.COM PHONE: 206-607-26001201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101#################### LICENSE NUMBER################------------MAY 202435022.008.021" = 40'GJRDMYDMYSTORM DRAINAGE IMPROVEMENTS PLAN 5 OF 5C6.532 OF 82MATCHLINE STA. 47+50 SEE SHEET C6.3REPLACE EXISTING STORM PIPEREPLACE EXISTING CATCH BASINREMOVE EXISTING STORM PIPEREMOVE EXISTING CATCH BASININSTALL NEW CATCH BASINREPLACE EXISTING CATCH BASIN GRATE WITH SOLIDLOCKING AIRCRAFT-RATED LIDSTORM DRAINAGE NOTESN0SCALE 1" = 408040EXISTING STORM PIPEEXISTING STORM INLETPROPOSED STORM PIPEPROPOSED STORM INLETSDSDLEGENDCONNECT TO EXISTING STRUCTURE 8''W8''W8''W8''W8''W8 ' 'W8''W8''W8''W8''W8''W8''W8 ' 'W10''W10''W10''W PRDMPH15TAXIWAY ARUNWAY 16-34TAXI W A Y A 7 (TYP.)157 LF59 LF152 LF73 LF128 LF200 LF127 LF35 LF 18 LFSCALES ACCORDINGLY.THIS SHEET, ADJUSTIF NOT ONE INCH ON 0" 1"ORIGINAL DRAWING.BAR IS ONE INCH ONVERIFY SCALESAPPRBYNO.DATEREVISIONSSHEET NO.DRAWING NO.DATE:PROJECT NO:SCALE:CHECKED BY:DRAWN BY:DESIGNED BY:PRELIMINARYNOT FOR CONSTRUCTIONR 90% DESIGNMBXKEYPLANRENTON MUNICIPAL AIRPORTTAXIWAY A RECONSTRUCTION/REHABILITATIONAND ASSOCIATED IMPROVEMENTSPlotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:C6.6 May 13, 2024 02:24:46pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C6.6 - UNDERDRAIN SERIES.dwg © 2024 KIMLEY-HORN AND ASSOCIATES, INC.WWW.KIMLEY-HORN.COM PHONE: 206-607-26001201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101#################### LICENSE NUMBER################------------MAY 202435022.008.021" = 40'GJRDMYDMYUNDERDRAIN PLAN 1 OF 5C6.633 OF 82MATCHLINE, SEE SHEET C6.7EXISTING STORM PIPEEXISTING STORM INLETPROPOSED UNDERDRAINPROPOSED STORM INLETPROPOSED CLEANOUTSDINSTALL 8" UNDERDRAININSTALL CLEANOUTN0SCALE 1" = 408040UNDERDRAIN NOTESLEGEND 10''W PRD10''W PRD8''W8''W8''W8''W8''W8''W10''W8''W8''W8''W8''W8''W8''W8''W8''W8''W10''W PRD 10''W 10''W 10''W 10''W AHEADLANEONEAHEADLANEONE AHEADLANEONETAXIWAY ATA X I W A Y A 6RUNWAY 16-34(TYP.)166 LF140 LF128 LF221 LF176 LF74 LF199 LF82 LF148 LF200 LF200 LFCONSTRUCTIONPHASE 2CONSTRUCTIONPHASE 125 LF 37 LFSCALES ACCORDINGLY.THIS SHEET, ADJUSTIF NOT ONE INCH ON 0" 1"ORIGINAL DRAWING.BAR IS ONE INCH ONVERIFY SCALESAPPRBYNO.DATEREVISIONSSHEET NO.DRAWING NO.DATE:PROJECT NO:SCALE:CHECKED BY:DRAWN BY:DESIGNED BY:PRELIMINARYNOT FOR CONSTRUCTIONR 90% DESIGNMBXKEYPLANRENTON MUNICIPAL AIRPORTTAXIWAY A RECONSTRUCTION/REHABILITATIONAND ASSOCIATED IMPROVEMENTSPlotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:C6.7 May 13, 2024 02:24:53pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C6.6 - UNDERDRAIN SERIES.dwg © 2024 KIMLEY-HORN AND ASSOCIATES, INC.WWW.KIMLEY-HORN.COM PHONE: 206-607-26001201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101#################### LICENSE NUMBER################------------MAY 202435022.008.021" = 40'GJRDMYDMYUNDERDRAIN PLAN 2 OF 5C6.734 OF 82MATCHLINE, SEE SHEET C6.6 MATCHLINE, SEE SHEET C6.8N0SCALE 1" = 408040EXISTING STORM PIPEEXISTING STORM INLETPROPOSED UNDERDRAINPROPOSED STORM INLETPROPOSED CLEANOUTSDINSTALL 8" UNDERDRAININSTALL CLEANOUTUNDERDRAIN NOTESLEGEND 12''W12''W12''W16''W 16''W 16''W 16''W 16''W 16''W 8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''WAHEADLANE ONE MPH15 MPH15RUNWAY 16-34TAXIWAY A4TAXIWAY A5 TAXIWAY A139 LF139 LF148 LF148 LF157 LF135 LF125 LF192 LF208 LF156 LF123 LF270 LF28 LF124 LF(TYP.)35 LF 34 LF5 LFSCALES ACCORDINGLY.THIS SHEET, ADJUSTIF NOT ONE INCH ON 0" 1"ORIGINAL DRAWING.BAR IS ONE INCH ONVERIFY SCALESAPPRBYNO.DATEREVISIONSSHEET NO.DRAWING NO.DATE:PROJECT NO:SCALE:CHECKED BY:DRAWN BY:DESIGNED BY:PRELIMINARYNOT FOR CONSTRUCTIONR 90% DESIGNMBXKEYPLANRENTON MUNICIPAL AIRPORTTAXIWAY A RECONSTRUCTION/REHABILITATIONAND ASSOCIATED IMPROVEMENTSPlotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:C6.8 May 13, 2024 02:24:58pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C6.6 - UNDERDRAIN SERIES.dwg © 2024 KIMLEY-HORN AND ASSOCIATES, INC.WWW.KIMLEY-HORN.COM PHONE: 206-607-26001201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101#################### LICENSE NUMBER################------------MAY 202435022.008.021" = 40'GJRDMYDMYUNDERDRAIN PLAN 3 OF 5C6.835 OF 82MATCHLINE, SEE SHEET C6.7 MATCHLINE, SEE SHEET C6.9N0SCALE 1" = 408040EXISTING STORM PIPEEXISTING STORM INLETPROPOSED UNDERDRAINPROPOSED STORM INLETPROPOSED CLEANOUTSDINSTALL 8" UNDERDRAININSTALL CLEANOUTUNDERDRAIN NOTESLEGEND 8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''WMPH15MPH15 MPH15TAXIWAY ARUNWAY 16-34TAXIWAY A3125 LF201 LF200 LF148 LF148 LF253 LF200 LF200 LF267 LF(TYP.)72 LF 22 LFSCALES ACCORDINGLY.THIS SHEET, ADJUSTIF NOT ONE INCH ON 0" 1"ORIGINAL DRAWING.BAR IS ONE INCH ONVERIFY SCALESAPPRBYNO.DATEREVISIONSSHEET NO.DRAWING NO.DATE:PROJECT NO:SCALE:CHECKED BY:DRAWN BY:DESIGNED BY:PRELIMINARYNOT FOR CONSTRUCTIONR 90% DESIGNMBXKEYPLANRENTON MUNICIPAL AIRPORTTAXIWAY A RECONSTRUCTION/REHABILITATIONAND ASSOCIATED IMPROVEMENTSPlotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:C6.9 May 13, 2024 02:25:03pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C6.6 - UNDERDRAIN SERIES.dwg © 2024 KIMLEY-HORN AND ASSOCIATES, INC.WWW.KIMLEY-HORN.COM PHONE: 206-607-26001201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101#################### LICENSE NUMBER################------------MAY 202435022.008.021" = 40'GJRDMYDMYUNDERDRAIN PLAN 4 OF 5C6.936 OF 82MATCHLINE, SEE SHEET C6.8 MATCHLINE, SEE SHEET C6.10N0SCALE 1" = 408040EXISTING STORM PIPEEXISTING STORM INLETPROPOSED UNDERDRAINPROPOSED STORM INLETPROPOSED CLEANOUTSDINSTALL 8" UNDERDRAININSTALL CLEANOUTUNDERDRAIN NOTESLEGEND MPH15MPH15TAXIWAY A2 TAXIWAY ARUNWAY 16-34127 LF136 LF104 LF233 LF83 LF140 LF107 LF224 LF125 LF(TYP.)75 LF 59 LFSCALES ACCORDINGLY.THIS SHEET, ADJUSTIF NOT ONE INCH ON 0" 1"ORIGINAL DRAWING.BAR IS ONE INCH ONVERIFY SCALESAPPRBYNO.DATEREVISIONSSHEET NO.DRAWING NO.DATE:PROJECT NO:SCALE:CHECKED BY:DRAWN BY:DESIGNED BY:PRELIMINARYNOT FOR CONSTRUCTIONR 90% DESIGNMBXKEYPLANRENTON MUNICIPAL AIRPORTTAXIWAY A RECONSTRUCTION/REHABILITATIONAND ASSOCIATED IMPROVEMENTSPlotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:C6.10 May 13, 2024 02:25:08pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C6.6 - UNDERDRAIN SERIES.dwg © 2024 KIMLEY-HORN AND ASSOCIATES, INC.WWW.KIMLEY-HORN.COM PHONE: 206-607-26001201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101#################### LICENSE NUMBER######################------------MAY 202435022.008.021" = 40'DSWCEFCTHUNDERDRAIN PLAN 5 OF 5C6.1037 OF 82MATCHLINE, SEE SHEET C6.9 N0SCALE 1" = 408040EXISTING STORM PIPEEXISTING STORM INLETPROPOSED UNDERDRAINPROPOSED STORM INLETPROPOSED CLEANOUTSDINSTALL 8" UNDERDRAININSTALL CLEANOUTUNDERDRAIN NOTESLEGEND M P H 1 5 TAXIWAY A7TAXIWAY A7227 LF 12" RCP @ 0.25% 299 LF 12" RCP @ 0.25% SCALES ACCORDINGLY. THIS SHEET, ADJUST IF NOT ONE INCH ON 0" 1" ORIGINAL DRAWING. BAR IS ONE INCH ON VERIFY SCALES APPRBYNO.DATE REVISIONS SHEET NO. DRAWING NO. DATE:PROJECT NO:SCALE: CHECKED BY: DRAWN BY: DESIGNED BY:PRELIMINARY NOT F O R C ONST RUCTI O N R 90% DESIGN RENTON MUNICIPAL AIRPORT TAXIWAY A RECONSTRUCTION/REHABILITATION AND ASSOCIATED IMPROVEMENTS Plotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:C6.11 May 13, 2024 02:25:30pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C6.11 - STORM-PLAN-PROF-090119000.dwg© 2024 KIMLEY-HORN AND ASSOCIATES, INC. WWW.KIMLEY-HORN.COM PHONE: 206-607-2600 1201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101 ------------ MAY 2024 35022.008.02 1" = 40' DSW CEF CTH STORM PLAN & PROFILE 1 OF 10 C6.11 38 OF 82N0 SCALE 1" = 40 80 40' 50 LF 12" RCP @ 1.07% 123 LF 12" RC P @ 1 . 0 7 % 18 LF 12" RCP @ 0.36% 122 LF 12" RCP @ 0.34% 18 LF 12" RCP @ 0.36% SCALES ACCORDINGLY. THIS SHEET, ADJUST IF NOT ONE INCH ON 0" 1" ORIGINAL DRAWING. BAR IS ONE INCH ON VERIFY SCALES APPRBYNO.DATE REVISIONS SHEET NO. DRAWING NO. DATE:PROJECT NO:SCALE: CHECKED BY: DRAWN BY: DESIGNED BY:PRELIMINARY NOT F O R C ONST RUCTI O N R 90% DESIGN RENTON MUNICIPAL AIRPORT TAXIWAY A RECONSTRUCTION/REHABILITATION AND ASSOCIATED IMPROVEMENTS Plotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:C6.12 May 13, 2024 02:25:42pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C6.11 - STORM-PLAN-PROF-090119000.dwg© 2024 KIMLEY-HORN AND ASSOCIATES, INC. WWW.KIMLEY-HORN.COM PHONE: 206-607-2600 1201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101 ------------ MAY 2024 35022.008.02 1" = 40' DSW CEF CTH STORM PLAN & PROFILE 2 OF 10 C6.12 39 OF 82 N 0 SCALE 1" = 30 60 30'N0 SCALE 1" = 30 60 30' TAXIWAY A6139 LF 12" RCP @ 0.45% 216 LF 12" RCP @ 0.13% 20 LF 12" RCP @ 0.10% AHEADLANEONE SCALES ACCORDINGLY. THIS SHEET, ADJUST IF NOT ONE INCH ON 0" 1" ORIGINAL DRAWING. BAR IS ONE INCH ON VERIFY SCALES APPRBYNO.DATE REVISIONS SHEET NO. DRAWING NO. DATE:PROJECT NO:SCALE: CHECKED BY: DRAWN BY: DESIGNED BY:PRELIMINARY NOT F O R C ONST RUCTI O N R 90% DESIGN RENTON MUNICIPAL AIRPORT TAXIWAY A RECONSTRUCTION/REHABILITATION AND ASSOCIATED IMPROVEMENTS Plotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:C6.13 May 13, 2024 02:25:57pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C6.11 - STORM-PLAN-PROF-090119000.dwg© 2024 KIMLEY-HORN AND ASSOCIATES, INC. WWW.KIMLEY-HORN.COM PHONE: 206-607-2600 1201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101 ------------ MAY 2024 35022.008.02 1" = 40' DSW CEF CTH STORM PLAN & PROFILE 3 OF 10 C6.13 40 OF 82N0 SCALE 1" = 30 60 30' N 0 SCALE 1" = 30 60 30' 63 LF 12" RCP @ 0.50% 32 LF 12" RCP @ 0.50% 115 LF 12" RCP @ 0.50% SCALES ACCORDINGLY. THIS SHEET, ADJUST IF NOT ONE INCH ON 0" 1" ORIGINAL DRAWING. BAR IS ONE INCH ON VERIFY SCALES APPRBYNO.DATE REVISIONS SHEET NO. DRAWING NO. DATE:PROJECT NO:SCALE: CHECKED BY: DRAWN BY: DESIGNED BY:PRELIMINARY NOT F O R C ONST RUCTI O N R 90% DESIGN RENTON MUNICIPAL AIRPORT TAXIWAY A RECONSTRUCTION/REHABILITATION AND ASSOCIATED IMPROVEMENTS Plotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:C6.14 May 13, 2024 02:26:11pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C6.11 - STORM-PLAN-PROF-090119000.dwg© 2024 KIMLEY-HORN AND ASSOCIATES, INC. WWW.KIMLEY-HORN.COM PHONE: 206-607-2600 1201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101 ------------ MAY 2024 35022.008.02 1" = 40' DSW CEF CTH STORM PLAN & PROFILE 4 OF 10 C6.14 41 OF 82N0 SCALE 1" = 30 60 30' N 0 SCALE 1" = 30 60 30' 21 LF 12" RCP @ 0.50% 90 LF 12" RCP @ 0.35% AHEADLANEONE TAXIWAY A5TAXIWAY A5 SCALES ACCORDINGLY. THIS SHEET, ADJUST IF NOT ONE INCH ON 0" 1" ORIGINAL DRAWING. BAR IS ONE INCH ON VERIFY SCALES APPRBYNO.DATE REVISIONS SHEET NO. DRAWING NO. DATE:PROJECT NO:SCALE: CHECKED BY: DRAWN BY: DESIGNED BY:PRELIMINARY NOT F O R C ONST RUCTI O N R 90% DESIGN RENTON MUNICIPAL AIRPORT TAXIWAY A RECONSTRUCTION/REHABILITATION AND ASSOCIATED IMPROVEMENTS Plotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:C6.15 May 13, 2024 02:26:21pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C6.11 - STORM-PLAN-PROF-090119000.dwg© 2024 KIMLEY-HORN AND ASSOCIATES, INC. WWW.KIMLEY-HORN.COM PHONE: 206-607-2600 1201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101 ------------ MAY 2024 35022.008.02 1" = 40' DSW CEF CTH STORM PLAN & PROFILE 5 OF 10 C6.15 42 OF 82N0 SCALE 1" = 30 60 30' N 0 SCALE 1" = 30 60 30' 113 LF 12" RCP @ 0.50% 47 LF 12" RCP @ 0.50% 74 LF 12" RCP @ 0.40%AHEADLANEONETAXIWAY ATAXIWAY A SCALES ACCORDINGLY. THIS SHEET, ADJUST IF NOT ONE INCH ON 0" 1" ORIGINAL DRAWING. BAR IS ONE INCH ON VERIFY SCALES APPRBYNO.DATE REVISIONS SHEET NO. DRAWING NO. DATE:PROJECT NO:SCALE: CHECKED BY: DRAWN BY: DESIGNED BY:PRELIMINARY NOT F O R C ONST RUCTI O N R 90% DESIGN RENTON MUNICIPAL AIRPORT TAXIWAY A RECONSTRUCTION/REHABILITATION AND ASSOCIATED IMPROVEMENTS Plotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:C6.16 May 13, 2024 02:26:37pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C6.11 - STORM-PLAN-PROF-090119000.dwg© 2024 KIMLEY-HORN AND ASSOCIATES, INC. WWW.KIMLEY-HORN.COM PHONE: 206-607-2600 1201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101 ------------ MAY 2024 35022.008.02 1" = 40' DSW CEF CTH STORM PLAN & PROFILE 6 OF 10 C6.16 43 OF 82N0 SCALE 1" = 30 60 30' N 0 SCALE 1" = 30 60 30' 65 LF 12" RCP @ 0.40% 111 LF 12" RCP @ 0.40% 191 LF 12" RCP @ 0.50%TAXIWAY ATAXIWAY A SCALES ACCORDINGLY. THIS SHEET, ADJUST IF NOT ONE INCH ON 0" 1" ORIGINAL DRAWING. BAR IS ONE INCH ON VERIFY SCALES APPRBYNO.DATE REVISIONS SHEET NO. DRAWING NO. DATE:PROJECT NO:SCALE: CHECKED BY: DRAWN BY: DESIGNED BY:PRELIMINARY NOT F O R C ONST RUCTI O N R 90% DESIGN RENTON MUNICIPAL AIRPORT TAXIWAY A RECONSTRUCTION/REHABILITATION AND ASSOCIATED IMPROVEMENTS Plotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:C6.17 May 13, 2024 02:26:51pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C6.11 - STORM-PLAN-PROF-090119000.dwg© 2024 KIMLEY-HORN AND ASSOCIATES, INC. WWW.KIMLEY-HORN.COM PHONE: 206-607-2600 1201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101 ------------ MAY 2024 35022.008.02 1" = 40' DSW CEF CTH STORM PLAN & PROFILE 7 OF 10 C6.17 44 OF 82N0 SCALE 1" = 30 60 30' N 0 SCALE 1" = 30 60 30' 104 LF 1 2 " R C P @ 3 . 1 0 % 191 LF 12" RCP @ 0.50%TAXIWAY A3TAXIWAY ATAXIWAY A3 TAXIWAY A SCALES ACCORDINGLY. THIS SHEET, ADJUST IF NOT ONE INCH ON 0" 1" ORIGINAL DRAWING. BAR IS ONE INCH ON VERIFY SCALES APPRBYNO.DATE REVISIONS SHEET NO. DRAWING NO. DATE:PROJECT NO:SCALE: CHECKED BY: DRAWN BY: DESIGNED BY:PRELIMINARY NOT F O R C ONST RUCTI O N R 90% DESIGN RENTON MUNICIPAL AIRPORT TAXIWAY A RECONSTRUCTION/REHABILITATION AND ASSOCIATED IMPROVEMENTS Plotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:C6.18 May 13, 2024 02:27:08pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C6.11 - STORM-PLAN-PROF-090119000.dwg© 2024 KIMLEY-HORN AND ASSOCIATES, INC. WWW.KIMLEY-HORN.COM PHONE: 206-607-2600 1201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101 ------------ MAY 2024 35022.008.02 1" = 40' DSW CEF CTH STORM PLAN & PROFILE 8 OF 10 C6.18 45 OF 82 N 0 SCALE 1" = 30 60 30' N 0 SCALE 1" = 30 60 30' 100 LF 12" RCP @ 0.40% 64 LF 12" RCP @ 0.40%70 LF 12" RCP @ 0.40% 118 LF 12" RCP @ 0.40% 153 LF 12" RCP @ 0.50% TAXIWAY A TAXIWAY A TAXIWAY ATAXIWAY ASCALES ACCORDINGLY. THIS SHEET, ADJUST IF NOT ONE INCH ON 0" 1" ORIGINAL DRAWING. BAR IS ONE INCH ON VERIFY SCALES APPRBYNO.DATE REVISIONS SHEET NO. DRAWING NO. DATE:PROJECT NO:SCALE: CHECKED BY: DRAWN BY: DESIGNED BY:PRELIMINARY NOT F O R C ONST RUCTI O N R 90% DESIGN RENTON MUNICIPAL AIRPORT TAXIWAY A RECONSTRUCTION/REHABILITATION AND ASSOCIATED IMPROVEMENTS Plotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:C6.19 May 13, 2024 02:27:21pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C6.11 - STORM-PLAN-PROF-090119000.dwg© 2024 KIMLEY-HORN AND ASSOCIATES, INC. WWW.KIMLEY-HORN.COM PHONE: 206-607-2600 1201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101 ------------ MAY 2024 35022.008.02 1" = 40' DSW CEF CTH STORM PLAN & PROFILE 9 OF 10 C6.19 46 OF 82 N 0 SCALE 1" = 30 60 30'N0 SCALE 1" = 30 60 30' 160 LF 12" RC P @ 1 . 2 8 % TAXIW A Y A 1 SCALES ACCORDINGLY. THIS SHEET, ADJUST IF NOT ONE INCH ON 0" 1" ORIGINAL DRAWING. BAR IS ONE INCH ON VERIFY SCALES APPRBYNO.DATE REVISIONS SHEET NO. DRAWING NO. DATE:PROJECT NO:SCALE: CHECKED BY: DRAWN BY: DESIGNED BY:PRELIMINARY NOT F O R C ONST RUCTI O N R 90% DESIGN RENTON MUNICIPAL AIRPORT TAXIWAY A RECONSTRUCTION/REHABILITATION AND ASSOCIATED IMPROVEMENTS Plotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:C6.20 May 13, 2024 02:27:33pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C6.11 - STORM-PLAN-PROF-090119000.dwg© 2024 KIMLEY-HORN AND ASSOCIATES, INC. WWW.KIMLEY-HORN.COM PHONE: 206-607-2600 1201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101 ------------ MAY 2024 35022.008.02 1" = 40' DSW CEF CTH STORM PLAN & PROFILE 10 OF 10 C6.20 47 OF 82 N 0 SCALE 1" = 30 60 30' SCALES ACCORDINGLY. THIS SHEET, ADJUST IF NOT ONE INCH ON 0" 1" ORIGINAL DRAWING. BAR IS ONE INCH ON VERIFY SCALES APPRBYNO.DATE REVISIONS SHEET NO. DRAWING NO. DATE:PROJECT NO:SCALE: CHECKED BY: DRAWN BY: DESIGNED BY:PRELIMINARY NOT F O R C ONST RUCTI O N R 90% DESIGN RENTON MUNICIPAL AIRPORT TAXIWAY A RECONSTRUCTION/REHABILITATION AND ASSOCIATED IMPROVEMENTS Plotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:DTLS-1 May 13, 2024 02:27:40pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C5.0 - STORM-DTLS-090119000.dwg© 2024 KIMLEY-HORN AND ASSOCIATES, INC. WWW.KIMLEY-HORN.COM PHONE: 206-607-2600 1201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101 ------------ MAY 2024 35022.008.02 1" = 40' DSW CEF CTH STORM DETAILS 1 OF 3 C6.21 48 OF 82 AIRCRAFT RATED DRAINAGE INLET1 B A SECTIONA SECTIONB SCALES ACCORDINGLY. THIS SHEET, ADJUST IF NOT ONE INCH ON 0" 1" ORIGINAL DRAWING. BAR IS ONE INCH ON VERIFY SCALES APPRBYNO.DATE REVISIONS SHEET NO. DRAWING NO. DATE:PROJECT NO:SCALE: CHECKED BY: DRAWN BY: DESIGNED BY:PRELIMINARY NOT F O R C ONST RUCTI O N R 90% DESIGN RENTON MUNICIPAL AIRPORT TAXIWAY A RECONSTRUCTION/REHABILITATION AND ASSOCIATED IMPROVEMENTS Plotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:DTLS-2 May 13, 2024 02:27:47pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C5.0 - STORM-DTLS-090119000.dwg© 2024 KIMLEY-HORN AND ASSOCIATES, INC. WWW.KIMLEY-HORN.COM PHONE: 206-607-2600 1201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101 ------------ MAY 2024 35022.008.02 1" = 40' DSW CEF CTH STORM DETAILS 2 OF 3 C6.22 49 OF 82 PIPE OPENING DETAIL1 WATER STOP DETAIL2 TYPE B MANHOLE OR CATCH BASIN3 FRAME ANCHOR DETAIL4 WALL CORNER SECTION5 AIRCRAFT RATED MANHOLE RISER6 SCALES ACCORDINGLY. THIS SHEET, ADJUST IF NOT ONE INCH ON 0" 1" ORIGINAL DRAWING. BAR IS ONE INCH ON VERIFY SCALES APPRBYNO.DATE REVISIONS SHEET NO. DRAWING NO. DATE:PROJECT NO:SCALE: CHECKED BY: DRAWN BY: DESIGNED BY:PRELIMINARY NOT F O R C ONST RUCTI O N R 90% DESIGN RENTON MUNICIPAL AIRPORT TAXIWAY A RECONSTRUCTION/REHABILITATION AND ASSOCIATED IMPROVEMENTS Plotted By:Bogh, Adam Sheet Set:############################################################################################### Layout:DTLS-3 May 13, 2024 02:27:52pm K:\sea_civil\sea_public\090119000.3 - renton airport - taxiway a\08 CADD\plansheets\C5.0 - STORM-DTLS-090119000.dwg© 2024 KIMLEY-HORN AND ASSOCIATES, INC. WWW.KIMLEY-HORN.COM PHONE: 206-607-2600 1201 THIRD AVENUE, SUITE 2800, SEATTLE, WA 98101 ------------ MAY 2024 35022.008.02 1" = 40' DSW CEF CTH STORM DETAILS 3 OF 3 C6.23 50 OF 82 GENERAL NOTES: UNDERDRAIN PERFORATED UNDERDRAIN PIPE UNDERDRAIN BEDDING UNDERDRAIN CLEANOUT UNDERDRAIN STAMPED COVER 1 4 3 5 5 UNDERDRAIN OUTFALL CONNECTION2 EXISTING OR PROPOSED DRAINAGE INLET