HomeMy WebLinkAboutMFP24003362.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Major Franchise Permit: MFP24003362
IVR Number: 24003362
Permit Information
Permit Name: Puget Sound Energy Gas Permits
Address/Location:07/02/2024Application Date:2423049113Parcel Number: 920 SW GRADY WAY
Permit Type:07/15/2024Issue Date:Franchise
Permit Work Class:07/15/2025Expiration Date:Major Utility
Job Number: 874044252-11985172Franchise Type:Natural Gas
Description: PSE Gas 2 excavations to examine the existing 20in gas main located NE of the Powell and 10th intersection.
Possible tree removal, street sign relocation, and pipe installation as necessary. Restoration per City of Renton
standards.
Contacts
Name Address PhoneTypeBilling
Corrie Rydberg
Puget Sound Energy
3702 71st Ave W
University Place, WA 98466
C: (253) 905-5031ApplicantX
INFRASOURCE SVCS B: (206) 949-5846Contractor
Business License Number: 36742Construction Contractor: INFRASL871C2
Puget Sound Energy Inc 10885 NE 4th Street, PSE08-N08
Bellevue, WA 98009
B: (888) 225-5773Emergency
Contact
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
Corrie Rydberg
Puget Sound Energy
3702 71st Ave W
University Place, WA 98466
C: (253) 905-5031Specialized
Billing
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
DEPARTMENT OF PUBLIC WORKS
Page 1 of 3 | Published: 10/27/2021
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN APPLICATION
Published: 10/27/2021
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control
plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents.
2. The following items are all required for submittal of the TCP Application:
☐Electronic Copy of the TCP Application
☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall:
Include map(s) showing the location of the project and work area.
Be legible lettering and clear, contrasting, symbols of viewing or printing.
Must indicate street names, and north arrow and scale.
Types of plans required:
o Work hour plan – show all mobility impacts during construction hours.
o Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
o Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
o Pedestrian access/detour plan, if applicable.
- Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the
Evergreen Safety Council.
3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].”
Project Name: Permit #:
Site Address:
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Construction Company:
Contact Name: Phone/Cell: _________________________
Business Address: City/State: Zip:
Description of Work:
Approval By: _________________________________________________ Date:____________________
Transportation Engineering
INFRASOURCE, INC
6905 S 228TH ST KENT, WA 98032
PLEASE SEE ATTACHED
874044252 - 11985172
1095 SW 10TH ST
Jeff Kiesz 206-348-2347
MFP24003362
Monday Friday 8:00am 3:00pm
Scott Warlick CED 7/15/2024
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 3 | Published: 10/27/2021
PERMIT HOLDER AGREES TO ALL THE FOLLOWING:
Must have approved Traffic Control Plan (TCP) prior to commencing the work.
Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time,
with the least possible inconvenience or delay to pedestrians.
WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the
traveled way.
Comply with all traffic regulations of the City of Renton and the State of Washington.
Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street
and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control
Devices.
Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public
transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends
and holidays) prior to starting any work.
Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum
of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a
temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a
minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140
with any questions.
Any lane or street closures not in conformance with the approved traffic control plan and/or without notification
of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at
thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles and
the acts of the Permit Holder’s agents and employees.
The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in
such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable
attorney’s fees and litigation costs incurred resulting from such claim.
In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for
legal counsel chosen by the City to defend against same.
Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
All permit conditions shall be met.
NOTES:
Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by a traffic control plan layout or reference to WSDOT.
Approved Temporary Traffic Control Plan must be at the work site during work hours.
Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery
road conditions during work and non-work hours.
Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company
logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous
place on the vehicle or equipment.
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 3 of 3 | Published: 10/27/2021
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555
NE 2nd Street).
I certify that the information on this application and within the submittal documents are accurate to the best of my
knowledge and I acknowledge all the requirements on this application.
Applicant’s Signature Date
Applicant’s Name (Print)
CORRIE RYDBERG
1095 SW 10th St Renton WA 98057 USA SW 10TH STPOWELL AVE SW
100'11111111
11111111111111111111
SW GRADY
WAYSW GRADY WAY10101010THOMAS AVE SW
SW 10TH
STKEEPR4-7BRIGHTW20-1ROAD
WORK
AHEADX'≥X'≥X'≥
RIGHT LANE
CLOSED
AHEAD W20-5RW1-4L1717W4-119maintain (2) 11' lanesX'≥X'≥RIGHT LANECLOSEDAHEADW20-5R W1-4LCONETOPPERKEEP
R4-7BRIGHT
W20-1
ROAD
WORK
AHEADX'≥
W20-1ROADWORKAHEADX'≥X'≥W1-4R
BE
PREPARED
TO
STOP W3-4X'≥X'≥W20-7ASTO
P
S/W
CLOSED R9-9BE
PREPARE
D
TO
STOP W3-4X'≥X'≥W20-7AS/WCLOSEDR9-9BEPREPAREDTOSTOPW3-4X'≥X'≥W20-7ASTOPW20-1ROADWORKAHEADX'≥BEPREPAREDTOSTOPW3-4X'≥X'≥W20-7ABEPREPAREDTOSTOPW3-4X'≥X'≥W20-7ASTOP
W20-1
ROADWORKAHEADX'≥THE FLAGGERS SHALL STOP THETRAFFIC ALL DIRECTIONS TOESCORT PEDESTRIANSAROUND/THRU WORK AREA0'60'30'NSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040Project Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVJaber Tofan206-406-8460Jaber.tofan@pse.com1 OF 11095 SW 10TH ST Renton WA 98057_recover0 11985172 06/26/2024Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless othe
rwise indicated,if indicated use ADA compliant channelization.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place during approved work hours asper jurisdictional requirements. (Generally between 9a.m. and 4 p.m. on non-arterials and from 9 a.m. to 3p.m. on arterials. If night time work is approved,signaling and flaggers shall conform to WAC296-155-305. Night time work to take place between_____________and ______________.)8. All Flagger and Downstream tapers shall be 50'-100'.LEGEND28" TRAFFIC CONESIGN LOCATIONTRAFFIC FLOWWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYWORK AREACHEVRONARROW BOARDFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPWORK PITMINIMUM TAPER LENGTH=L (FT.)LANEWIDTH101112207075802510511512530150165180352052252454027029532045475495540POSTED SPEED (MPH)505005506005555060566060-66072065--78070--840TEMPORARY TRAFFIC CONTROL PLANPuget Sound EnergyTraffic Control Supervisor:Jaber TofanCard No. ES2 000434Card Exp. 02/18/2028Jaber.Tofan@pse.com(425)424-7316MFP24003362
Est. Start Date:
&
&
&
&
&of CL of CL
Tie-In Fitting
Route #'s:Bollards:2.5" #4" #ADA Ramps #:
Del Press:Traffic Signal:Bus Stop:
No Parks #:
Meter Loc:Trolley Lines:Mtr Hoods #:
Meter:Speed Limit:
EFV:Police #:TCP:
Diameter:Flaggers #:Arterial:
of CL
Service Information Street Information Job Type
of CL
of CL
of CL of CL
of CL
of CL
of CL
PLAT Map:
Work Location Size of Cut Surface Type
Job Description / Scope of Work
New Construction:
Construction Method
PM / Inspector:
Est. Duration:
Jurisdiction:City / Zip:
ROW Permit:Customer:
Job #:
Date:Address:
Puget Sound Energy Gas Pre-Inspect Form
N
PPMP, Major Projects
N
GAS GAS GAS
GAS
GAS
GAS
GAS
GAS
GAS
20" STW HP 5'
S
O
F
N
E
S
M
T
L
I
N
E
67E208
Water
Sewer
Storm
Drain
Sewer
P/LP/LExcavation
approx.
20ftx8ftx12ft
Excavation
approx.
10ftx8ftx12ft
Street sign may be
relocated to the west of
the intersection to
accommodate
excavations
Tree may be removed to
accommodate excavations
MFP24003362
RESTORATION PER CITY OF RENTON STANDARDS
950 POWELL AVE SW
ΟΝς∆ΚΚ ≅Υ∆ Ρς−Ρ−ς− 0/ΣΓ
Ρ
Σ
Ρς ΦΘ≅ΧΞ
ς
≅
Ξ
981 POWELL AVE SW
W
P
W
PIV
C
C
PB
PB
P
T
C
S
S
D
D18" CONC.36" CONC.
36" CONC.108" CONC.CONC. SIDEWALKGRASSCONC. SIDEWALKGRASSGRASSCONC. SIDEWALK
CONC. SIDEWALKCONC. SIDEWALKCONC. SIDEWALKGRASS
GRASSASPHALT ROAD
ASPHALT ROADASPHALT ROADASPHALT ROADD/W CUT\A1;ASPH. D/W
D/W CUT\A1;ASPH. D/W
CONC. SIDEWALK
GRASS108" CONC.
108" CONC.
20" STW TRANSMISSION LINE
W 36" CONC.
ΡΒ≅Κ∆9 0! <
0 10
1/&
4020
µ
LYNNWOOD
FEDERAL WAY
C O N S U L T I N G E N G I N E E R S, L L C
3500 188th St SW
Lynnwood, WA 98037
Civil Engineering
Project Management
Land Surveying
Landscape Architecture
Land Planning
www.esmcivil.com
(253) 838-6113
(425) 297-9900
Suite 633
Public Works
84/ ΟΝς∆ΚΚ ≅Υ∆ Ρς+ Θ∆ΜΣΝΜ
∆ΡΛ ΙΝΑ ∀2//,0865,/12
ΟΡ∆ ς−Ν− ∀763/33141
Χ≅Σ∆9 3.00.1/13
ΡΓ∆∆Σ9 0.0
UTILITY LOCATIONS PROVIDED BY C-N-I LOCATES IN MARCH, 2024, WEREMARKED ON THE GROUND FOR PUGET SOUND ENERGY, AND WEREUTILIZED FOR THIS MAPPING.
CITY OF RENTON GIS RECORDS WERE ALSO UTILIZED FOR THISMAPPING.
ΜΝΣ∆
Κ∆Φ∆ΜΧ
INFORMATION SIGN
S SANITARY SEWER MANHOLE
STORM DRAIN CATCH BASIN
DSTORM DRAIN MANHOLE
A.D.A. RAMP WITH DETECTABLE WARNING PLATE
LEFT TURN ARROW PAINT MARK
RIGHT TURN ARROW PAINT MARK
G GAS
P POWER, BURIED
D STORM
S SEWER
STORM, >12"
W WATER
STRAIGHT ARROW PAINT MARK
P POWER VAULT
FIRE HYDRANT
FIRE DEPARTMENT HOOK UP
W WATER MANHOLE
PIV WATER POST INDICATOR VALVE
TELEPHONE RISER
C TELECOMMUNICATIONS MANHOLE
POWER TRANSFORMER
T TELECOMMUNICATIONS VAULT
SEWER, >12"
TELECOMMUNICATION, BURIED
LIGHT POLE
PB
WATER METER
WATER VALVE
ROAD CENTERLINE
STOP BAR
LANE STRIPE
EDGE OF CONCRETE
ROCK
RIGHT OF WAY LINE
CENTERLINE OF RIGHT OF WAY
ELECTRICAL JUNCTION PULL/BOX
FOUND MONUMENT IN CASE
LANE INDICATOR
DASHED LANE STRIPE
GAS, >12"
Excavation #1
approx. 20x8x12ft
potholed top of
main at 94in
Excavation #2
approx. 10x8x12ft
Contractor to protect existing city infrastructure during excavation.
Coordinate with city inspector Tom Main in the field. Additional utility
protection may be required.
MFP24003362
This permit is for Major construction work in the ROW and will be billed at an additional
$158/HR for inspections. After hours and weekend work will be billed at $175/HR
WELD DETAIL
PLAN VIEW
REPAIR SLEEVE DETAIL
VICINITY MAP
SAP ORDER #XXXXXXXXXBILL OF MATERIAL ASSOCIATED
SOLELY WITH THIS SHEET OF THE
DRAWING
FITTER'S CHECKLIST
REVISIONS
GAS MAIN PRESSURE AND TESTING
STANDARD DRAWING ST3D3-194
CONSTRUCTION NOTES:
BACKING STRIP DETAIL
WELD PROCEDURE TABLE
CALL (800) 424-5555
2 BUSINESS DAYS BEFORE YOU DIG
JOINT FACILITIES ARRANGEMENTS
STANDARD DRAWING
REPAIR SLEEVE
FOR DAMAGED PIPE
.
ST3D3-194
1/1
BILL OF MATERIALS
250
250
20
2024
48" length
MFP24003362