HomeMy WebLinkAboutRS_Site Illumination_Memo_240614_v1.pdfTENW Transportation Engineering NorthWest MEMORANDUM DATE: June 3, 2024 TO: Mr. Dale Fonk FROM: Trevin Roletto, P.E. TENW SUBJECT: Off-Site Photometric Calculations Summary Project Name: Sunset Highlands Medical Clinic TENW Project No. 2024-140 ADF Properties, LLC has requested that TENW prepare street lighting design plans and associated photometric calculations for the new Sunset Highlands Medical Clinic located at 4409 NE Sunset Blvd in the City of Renton, Washington. The Sunset Highlands Medical Clinic project has approximately 185-lf of frontage along NE Sunset Blvd that required illumination analysis. The results of our analysis are summarized below. Target Criteria The Target Criteria established from the Renton Municipal Code 4-6-060 Section-I, Table I-3: Average Maintained Illumination is summarized in the table below. TARGET CRITERA Calculation Area Avg. Value (FC) Max. Uniformity (Avg. FC/Min. FC) NE Sunset Blvd (Principal Arterial) 1.3 4.00:1 Existing Conditions TENW conducted a site visit on May 22, 2024. The existing street lighting along the frontage of NE Sunset Blvd includes three (3) existing LED light fixtures mounted on steel light poles. The LED light fixtures are AEL Autobahn, mounted at 30’. See attachment B for the light fixture location. TENW modeled the existing illumination conditions along the frontage of the project using AGI32 v21.2 software. The results of TENW’s analysis are summarized in the table below. EXISTING CONDITIONS Calculation Area Avg. Value (Lux) Max. Uniformity (Avg. Lux/Min. Lux) NE Sunset Blvd (Principal Arterial) 1.34 2.23:1 Transportation Planning | Design | Traffic Impact & Operations 11400 SE 8th Street, Suite 200, Bellevue, WA 98004 | Office (425) 889-6747 Memorandum – Sunset Highlands Medical Clinic Existing Photometric CalculationsTENW June 3, 2024 Page 2 Conclusions TENW has concluded that the existing light levels along NE Sunset Blvd meet current City of Renton standards. Thus, additional street light poles are not necessary as the existing light poles along the project frontage achieves the required City of Renton standards. Please contact me with any questions at 425-250-0583 or roletto@tenw.com. Sincerely, Transportation Engineering NorthWest Trevin Roletto, P.E. Attachments Attachment A – Renton Municipal Code 4-6-060 Section I Table I-3: Average Maintained Illumination Attachment B – Photometric Calculations – Existing Conditions Memorandum – Sunset Highlands Medical Clinic Existing Photometric CalculationsTENW June 3, 2024 Page 3 ATTACHMENT A Renton Municipal Code 4-06-060 Section I Table I-3: Average Maintained Illumination March 2024 Memorandum – Sunset Highlands Medical Clinic Existing Photometric CalculationsTENW June 3, 2024 Page 4 Memorandum – Sunset Highlands Medical Clinic Existing Photometric CalculationsTENW June 3, 2024 Page 5 ATTACHMENT B Photometric Calculations - Existing Conditions