Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Large Format
• > STREET TREE NOTES: 1. TREES SHALL GENERALLY BE PLANTED BACK OF THE SIDEWALK. PLANTING STRIPS WILL BE APPROVED ONLY AS PART OF A LANDSCAPING PLAN IN WHICH PLANT MAINTENANCE, COMPATIBILITY WITH UTILITIES, AND TRAFFIC SAFETY ARE DULY CONSIDERED. 2. IF PLANTING STRIPS ARE APPROVED: A. MIN. DISTANCE FROM CENTER OF ANY TREE TO NEAREST EDGE OF VERTICAL CURB SHALL BE 4 FEET. B. TREES SHALL BE STAKED IN A MANNER NOT TO OBSTRUCT SIDEWALK TRAFFIC. C. IN CASE OF BLOCK-OUTS, MIN. CLEAR SIDEWALK WIDTH SHALL BE 5 FEET IN RESIDENTIAL OR 8 FEET IN BUSINESS DISTRICTS. 3. ON BUS ROUTES, PLANS SHALL BE COORDINATED WITH METRO SERVICE PLANNING. PHONE 684-1 622. ------- FIRE HYDRANT OR UTILITY POLE SIDEWALK NEXT TO VERTICAL CURB ~ I ..___, § WMTI. 50' MIN <( LUMINAI 15' MIN. I ~1r---_'-~ PLANTING STRIP ~ ~~ f§ Q' Mlt:,j. NOTE 1.-~~ STREET TREE NOTES: 1. TREES TO BE PLANTED AT APPROX. 40' ON CENTER, WITH ADJUSTMENTS FOR UTILITY FIXTURES AND MAILBOXES. 2. HOMEOWNERS SHALL BE RESPONSIBLE FOR TREE MAINTENANCE FOR TREES WITHIN OR ABUTTING LOTS. 3. STREET TREES SHALL BE: LARIX DCCIDNETALIS (WESTERN LARCH) LOCATE 5' BEHIND THE SIDEWALK (OR CURB, IF NO SIDEWALK) STREET TREE STANDARDS VERTICAL CURB LINE AT IHTERSECTION A PORTION OF THE SW 1/4 OF SECTION 29, TWP. 23 N., RGE. 4 E., W.M. NO REPLACEMENT TREES ARE REQUIRED OR PROPOSED. TREE INVENTORY: LEGEND CLEARING LIMITS SSMH RIM~376.5 PROPOSED CONTOUR ~ --- EXIST. TREE *10" PINE EXIST. TREE TO BE REMOVED -10" PINE BLOCK 4 Al<ER 1 S FARMS ND. 5 VOL 40, PAGE 27 LDT 12 130 01' GRAPHIC SCALE ,-,of\ .) ) ' (J) (\J I ...; I 13 SIGNIFICANT TREES: 7 TREES TO BE RETAINED 6 TREES TO BE REMOVED REQUIRED TREE RETENTION (PER KCC 16.182.156) 5% OR 10 TREES PER ACRE (WHICHEVER GREATER) SITE AREA: 0.34 ACRES 0.34 (10) = 3 TREES REQUIRED TO BE RETAINED l_DT 13 , --- .I I I EX HOUSE STREEJ _ _JREE -WESTERN LARCH (LARIX OCCIDENTALIS) PLANTED 5' INSIDE OF R.O. W. LINE ( 4 TREES) King County Department of Development and Environmental Services APPROVAL FOR SITE CONSTRUCTION Review Engineer ENGRCOMP Date Senior Engineer ENGRCOMP Date 20 0 10 20 40 80 -==-=-;::r, ,r·•, 71 ,,.771 ,Mme r r:nrrirm1:1fr-rTrrrer~ DEVELOPMENT ENGINEER APPROVAL Date ( IN FEET ) Comments: 1 inch = 20 ft. (o·) /l!i!J c,:-Cl) ~ c:· C ui = "" 11'!11 ci CY) d @ :::,. (.) CJ ~ :z ~ @s REVISIONS: . REV. PER CTY. OMMENTS 10-1-0 2. REV. PER CTY. COMMENTS 10-20-08 "' u w -, 0 "' (l_ C) z [t w w z C) z w h ~ a ~ E,... a i...:i ~ b ~ c;j f;j ~ :;.;,; '<!I ~ -Cl -+-' ll.; so ~ 0 .... g:5 "i< in ~ .... DATE: 3/16/07 SCALE: 1" = 30' DESIGN BY: JJJ DRWN. BY: JJJ APP. BY: FILE No. SHEET ~--=1 __ OF 1 ·, I - -.- i ' ·, ·--------------.-------- 375 1+00 2+00 172nd SCALE: 1" 1" - 20' HORZ. 5' VERT. SE ST. (URBAN SUB ACCESS) 1 -----f: _ +-·r _._, ______ ' i-----1---f----r---t---' -------w •• _:-:r~=-- ~--3 9_,,,__0_f-N----\ =---=~---_ ·=-i -_ ---~-r-----,-------1---1 __::~-FILEi@EXI r=--'----~];:~=~~=:= ----~ c, " ~ I ~-(Ll;-----. ·---------, -· ;·r_ 1st P\liXf:'tbcE ---~--a.I'-" -.. , --- -g-i ----_-----,-----~1----e--~--+--r----1 ____ ,1··--11_ -+-----~:c; ___ , -__ -- 6-----------:------:-------_---------~"-==---=·=-~--r---1 ==PJO[ILE ~~P_Ripl'OSE6 '.;'i~ -1 ---385 385 ---------- ,____ I r·_.J ----1·-----.--·-1[11-=4.61'1:' --. ---~,1: ! ------380_ . I :_ ... -~. , '' I 380 r--------· ---i---- ---t01°46ct;-f-4c55-T----:--------1 ~------1-·+----+ -375 r-·1 ·· ,----b01i PT -Of-CURB ---------'---1--·-·' --T---r··-·--·-i--r--- ----·--i---j--·----T.CB rf··p:-,:<2E:-+}----: I -------·· -· r· --1·- ---_-_ -----------1· ---r-~M1,-?{~·1,·i:-x~1i-;;------: ---'----·---r-----------1 -~----- 370 375 370 (D -<ti n1 N 0) VI ~I ~I ~ii 10+00 11+00 SE r-' V) ~ X--._ w 0:: SCALE: 1" 1 " VARIES 5' 20' HORZ. 5' VERT. 30' 106th AVE. SE (URBAN SUB ACCESS) 12' A PORTION OF THE SW 1 / 4 OF SECTION 29, TWP. 23 N., NOTE: PER KCRS SECTION 4.10F, A 1 INCH FULL WIDTH OVERLAY SHALL BE REQUIRED ALONG THE PROPERTY FRONTAGE OF 106th AVE. SE AND SE 172nd ST. APPROPRIATE REPAIRS TO THE EXISTING SUBGRADE, BASE MATERIAL, SURFACING ANO PRE-LEVEL. MAY BE REQUIRED PF\IOR TO PL.ACING THE OVERL.A Y. THE OVERLAY MAY BE WAIVED ONL. Y UPON WRITTEN REQUEST AND AFTER AN EVAI.UATION OF PAVEf~ENT COf\lDITIONS AND /OR CHANNELIZATION REQUIREMENTS HAS BEEN COMPLETED BY THE COUNTY ROAD ENGINEER OR DEVELOPMENT ENGINEER. EX I SSMl=l- RIM'=383.0\ ,, ... I .,..._ /f-15 EX. 12' CCP rs /TINV=381.5 BLOCK 4 AKER'S FARMS ND. VOL 40, PAGE 27 LDT 12 5 RGE. 4 E., ( i FL0 1r.' Lli"IE TO BE Dic,l::CTED TO CATCH BJ\Sl1··J A':) SHOWI\J ON r-L;-\N I 20· -~------- / w ---::z:: :J f- 0 . 1 • _J I rn· --··-I --------------- / A.C. PAV'c:t~ENT .-.-) ---- ' l THICKENED 3' I EDGE CURB '"-----·---' i , ·,,·-,-, .,1 i ____ :_-~% __ <_ ---_--,.-_-c_··-· _-,-,-_-_,-··_·-__ ----, , • --s::.:::=v;;:;:;--/7/~7/0--:-,,,;, )/,'.>//~~'s/J,:~-;/~~r~:~:---=:==~--'----~.::_::-,~~-==r=~~:<: . : --=~ ~~~ -; :-:--.--,-,--,"-:;·:-, --:~-:J \ \_ - /2" MIN. COMF'ACTED DEPTH USH[O SURFACING TOP COURSE 2 1 /2" MIN. COf~PACTED DEPTH Ci',USHED SUf,FACING BASE COURSE I.:~· I ··.; -.:1 i "{ __ l~L I( I -- -·rl 300.01' (CI\LC) 3CO' (Pl.AT) ADDI TIONAl, TREATMENT MAY BE REQUIRED DEPENDiNG ON SOIL CONDITIONS. SEE SEC. 4.02 'I' l< i\ C 'I' 8 C:J-I 11 ( __ (_, •• W ,:t-L HA" 130.Ul' -------- ,;i,. ~ ~ 1:, //./ ('/ ·u1\ 1£ I~ IIW~P __JOlr!T USE DRlv'[WJ\ Y TRACT 3+00 l•i. T. S. i' I\Wt,j l' ~I ~ 11 i I vJ 12' CONC. RET. wu· ~ II 11 'f 'JALL \./ITH ~ '----\--,--I EXTEND NEW ASPHALT TO STREET TREE (TYP) -WESTERN LARCH II Hi II ,~_.,......----r---EXIST. DRIVEWAY ASPHALT \./ODD FENCE ~LA~~~Mo~c~~NT~~1:\:L¢r~Tlf)·------,. ··-., / ~/! ~\ ~;~,:i~\~~DN ~ClNC. / EX HOUSE : ,~'.1 rc\./ALL o;i PROP LN) '"-J w I \ jl ', , 20' LONG DISPERSAL TRENCH I ' / ' ·· r·.--~-1 o); , 1 _L/',, ----__ ll[OR R.9Q_F DOWNSPOUT DRAINAGE 1 ~fM1iY,E CONC. I i:tl Q4 • f \~ '75 \ \ II ---. -------1,.--_J /I RET. WALL -11::~-:5~1:J,'< 1 : I \__ ~--)-----.-e--, S88' \~;~E 130:~9~--,- SIDEWALK TRANSITION RAMP---~-f .><::t: II ·,.,Jf,;c I 1--1.1 ·--~9 ·82 ' -------~ ---_:'50.20' 1 ,......1 •• ' II 7"' __j____ ----'----"1------l . ROP LINE--------·,/ 1 1··-!-i"'-I : ; EX GRAVEL _____ li--1 1 , GUTTER & SIDEWALK I 1 :[._: ---.,Jr'; T-----1L--. _ / DRIVE i 'I CAR-, . . ----PORT I I ·I . :I I , ~ 1 b-I , " ,-_ J 1 1 1 , PROPO,,Eo~J!L 111 \ 7,f;?-q. E sy'.TREES\\ ;, 1 t ____ J I 1 coNTourRs .+--~Ir~ 30_'-=',l1~11 o R~MAIN RQ'f _# 031 ~ LOT: # f-,', J&o . ';:/ / 11 1 1 ~ \'}\:C \ }:j}z/ ?~ I "' 5 572± I SQ. FT. -----------1' ·--" I ~-' Id I\ \-ii " 1;J • P,1 '.s.:4 ,190± SQ. FIT. I I[) , l I I ·--. ' '-(, / I <fc > ,, ) \ / , / I K/! · ';''-I VJ\ , , Fv 1--I , 1 ~~\; EX HOUSE I \j \ I 1t: '1 0 I··: " Ii~,\ ', 20 \~,> ( 3) 10" / I I (REMOVE) I I 6 ,1°+, II '-'~ > \/:, PTNE" / I I I & INSTALL NDCBU COORD ···I"' / I ' :,,-'I -.Y' > . CD -~=··---Q\ I Q\ . co ru (f\ 0 REMOVE EXIST. MAllBOXES :~ 1.~I g flt-\~.-.\\j;I.~A~.\."f" ~ ', \\i15;8~' : 1-I g:; , o 1 _ 1 }-"fl R . ·-t I WIDTH \ , o , ;::: I - TH/C'f(E-.-!VEO E[JGE AS'Pl-lAL T DETAIL ,----------NOT 70 SCALE LDT EX HCJUSE 1. ) _) w/ POSTMAN) ';;z.:::;>, / ~ j;: -J~~ ~NE _ T_: ~8~ A'.c¥H. v0 : ~ 1 \2 S ? 0+46.1, 14.55 _RT __ '-' ~J u.._J ~---1..ti'o ' : . I"''; r 20' LO r \ ./J 8 I I Sf L W PT OF CURB , ,,, l'.J , ,-1 ' 5il II f· "L'., 1 1 J 331+ 1![.-Q ET _____ .J • STREET rREE -WE'STEF,N LAF,CH CB TYPE 1) __ , /Cl V). '/'-, JI'· \ '?r'I--D -~-' t, -'" ' ~---i----w I CU -----·----' RIM: 377. --. ·, Ld l,j -..._I' :1~+~t~-: -·------~-·---20' LONG CJISPERSAL TRENCH --;' /(~ARIX ~CCIOENT~l.lS) PLAl~TlU _ c . . . ~\ w " '1' I I l" 70J -' --' ' EX 12' RC C) \ IE· 375 4 (NEW 12") ', :J / 1 1· 1 'ff "' , TO REMAIN c', • ' 1 --• ' J -. , Vl ;' EX ELEC PO VER POLE . . . .. ,,.____ , . I .. ':-\ ,., D 1 1 w r!NV=3853 . y PSE <''l, 1993 KCRS) SET OVER EXIST. 12" -:x:-i 16+s .24 ( [1 'L~·. -\25' RAD To BE DEDICATED -In I <REMOVD / --To BE RELDCA rED B , . ' Pf :I c'6 11 -I 1. \. /'... " I • » I :3"' , ,! I a C , , j » ' ' EX!Sl. CB 14 -12 DUJ;L_ , , I .:V '· r oT1 P'i ,;_ _ , \ lfl _6_. PVC LOT DRrrN '-• ' / ; ASPH APFWN Ex. 12' RCP Rl u=3773 , IRON@ 1.43% r .,."-/"'-~? ,I c·lJf Ii ~-DOUBl;E HCP RAMP-.. _.,....-----I STUB (TYP) " ---.,_ ',, / ; I EX. 12' RCP ·11,v=··903 ,., . •,,, -n-. , : , '· '(,A , \ " .. , ~ -1 7·--' , -(REMOVE) , J • JNV=375.2 N. 18' RCP (EX) REMOVE J ~ -. ,1 ,, ,_. ---P' ELDCATtp F.H. , ..-----BRlvEWAY_-=---EX. 12 ------.,\ / --. /' JNV-38o.7 , !NV=375.2 E. 12' RCP CEX) "REMOVE'--; f-1 "-.,\h"" i' ', \~ \V \ _ NEv/ ELEC.'R.Ovl§B~-i\ CURB DROP ~ (REMO VD /.. kt? / /Jz,0 12" INLET IE. 387.2 INV=3751 S.\./. 12' RCP (EX>,_'. \ ----'s.C{ I \"'' , I I ·~ \ Q '{OLE L~~~ON (BY P~E) • _ ~ _ ~ 50.30 ', , ~-,.,{ / _L I __ ,--. /'1:'I RIP ~/\~--~ _ ,-,_:---- IE• 375.2 02· D NE\./ \ O!''·,, '\ I ,_1 5~ , "c.:.:; '-. ;-_:_n 53,3:i __ 9 __ =-·-_ ,-, _ ~-1 ~:: ~l=:71_~£ ~ -= .:.1'._Lf~·1 __ _ IE• 375.2 (12' N) NE\./ g:t'P / .--; , '"-' '0\, .t':-:·:· : < / . ------. 1f ... --~:---~-"-_-_1__3,0-:=JO-:_--= -_=.:::_·-~~ .c._ :;l:_j -\--;-L\-t'!JGE OF PAVEMENT ADD souD, LOCKING LID / , I w v ;; -•• ;, _ ~. --e ~ ·~= __ --"-:=----,:p~-~-_:::-___ ~EflJ--SA~cor·-------I \ ·, \ : __ _ ,..-,---, 1. '.:.-.,-;' ;"-<--= -z:i'-1~i51--f~--roo· cuRBT J \ ,. 1 ,';:s', -\--\ -----·- , I r~BJ'l / L35; RAD ____ ----"',-y------1-16-22% ;· I ;;"'1 RAD. --r -/\ __ E;<__ft,VEftf-N_1__ i-lcn, '\--1·----\. 5'-12" CPEP @l 27.:,% EX ELEC/ PO_vl_E:_R_POLE --_.r..---, f ,,,o \ ' g, i L~ -/---l -CENT ERL ':-/ I , ' _ TO BE RELOCATED ! //-38'-)2" CPEP@ 7.11%-' '()~ \ ' ------,-.-72ND ST ' I 1 , \ \ \El!GE.O[_['AV[i~ENT BY PSE ,(PER 1993 KCRS), 11;1 _ _ _ ___ -t--\PROPOSE);) J ·s E 11 . __ .__ _ __ L~i--,-_::__ _1---. -=----j __ , ' tl_ --r-P ~ ,coNTOURs · , , -~ --1----.cv .---1-_ ----, --------------' -f_ \ vJ ' ~ ---/ ', -----1 -cc:=-::-::-t.:-_ ~ -\ --~ ---_ ___;.) _ · : W __ OENTERLJN_E-8.0-,----1-"'-----\:-~-::...:c --;1 00 --=.=-~\.-'--,-~-, --/ (, _ :---=--c:---~'-'-T_cn t;;:, --------I \ .c.-----' • -, \____ . ---· G':!'' \\;I! --------: -'/; S I i-00 \ \,\[NI _ ~---------\ ' _. _. -__;:r---.'"--------\ ~; ~ ------. ;? I \ , . , , // [DG[ Of_PAVf_ (~ E1(ISTINCi, FIRE'l::/YDRANT_.-" .---/;;.~: -------; l/: . f \~2+76, __ 2~.5 LT ' ---~----\ TO BE RE'(.DCATEJJ.. .. ~< ----<,/'/ '\ _ _ j I CF3 ,¥1 (TYPE 1) -I -\ (BY C-ONTl;_~f.TOR)--; __ .-.-:, ,, [__CURB PC lQIBB PC I \\ F~M: 388.50 :;,, ____ / · '--. .---\...----./-2+18.74 2+23.59 / IE:385.56 ·----£ ,~~~ pp~ -------;;,;c:·=~\\-----,;f/ I 'l SIDEWAl.K TRANSITION RAW' 12' RCP # I ·-', -->,C: , t--:1-----' \:, \1±52.39, 21.2' LT / (DETAIL SHT. 3) .,. ·-. ..----_ ... (----'o'o CB #2_ (TYPE 1) -2 +52 -28 INV=369.7 . .._ --------END CURB, CUTTER & S!DEY'/ALK ,a , _ --.. ;;\ RIM: 380. 91 6sMH ,; ,i,~i , :, -IE: 377.9 RIM=376.5 1 .. J n5" I-1/4" EDGED -GROOVE /"R\ 20% '~~!.....====:___--I J LJSP-r f\ y-~r"v ~J King County --,, ~I' ~" o" ., so% 6 I ' ==.-:__L..=:=rr:.~.:'.. ,I._ - Liq:.iurtmrnt of Development and Er1vironmcr1tol Services NOTE: [.. _'.'' , .. , , I ,, , ~16" " ,; ------~· -' - I 1s" I ~---- *NOTE: TOP OF CURB @ DR/VEWA YS 1. TRACT "A' IS A JOINT USE DRIVEWAY TRACT TO BE JOINTLY OWNED AND MAINTAINED BY LOTS #2 ANO #3. 2. EXISTING WATER MAIN SHALL BE LOCATED BY POTHOLING PRIOR TO INSTALLATION OF DRAINAGE SYSTEM. !-·, " - GRAPHIC SCALE 20 o 10 20 40 80 I l I I . I APPROVAL FUR SITE CONSTRUCTIOI, ------------------------~---------- ---------+-~---------i fic,iew Enginee1 ENCl<COMP Date --------------+--=-~~~~----1 Sc11ior Engineer ENGf<COMP Dote CEMENT CONCRETE VERTICAL CURB AND GUTTER ~ . • • <W,l,.'s/i~,\ .. ;..r.,~;;'i-~~''" .. ' -~--.,,,---_ --~'It, -__ --~.--''"''·"~-,,,,,,.,,¥,,-,rt,i,;J.ili\'t,!_-~ 'ii' -'i/!I ~:l~ lilliFJtilft"Li:·ID:E . ( IN l'EET ) 1 inch = 20 ft. -oc,1ELOPME-N--I f:NC-IN_E_· E-R~-+---A--P--PR··~o"'v~A~L~D~a~te--; Cc,1nmeni:.s: NOT TO SCALE: ------~---------·-----~----------~ f~[VISIONS: 1----------·- ~"<EV. __ PER CTY. ~OMMENTS 10 --1-·0, 1-----------·----- --------~------ ,__ ___________ _ r--------------.-----· 1-----------~- --------------··-···- --·--------, ----------- ------- e' u w , 0 0: [I_ (j z er w LlJ z (j z LtJ h ~ ..:i Q, t-< ~ C:) ~ C/J (---.; C) ..:i {."':) :::::> ~ ~ u - h Cq ";i ~ VJ fl, r1) Cl s: ""-"P; "' C) n-"" .q ,;., q 'O h C:.) < --. •-,: "' k1 ('-;, ~, c::, ,, t--~· ,-; ..::; '~ ~ ~ 1----------~-- 3/16LD7 1----------- SCALE: 1" = 3()' DESIGN BY: __ ~JJ~J- 0-----------·- DllWl1. BY: _ ___,I.)_,!_ 1----------·--- APP. BY: 1------·---- FILE No. Uc '---------------------------------------------------------------·-------·---------------------------------·--------------------'----·-----~ [Jf]@@&awg@ NOV 312008 Kc. D.D.E.s. '' / / CONDITIONS OF APPROVAL ® King County Departmont of Developmcn( ~nd Enviromnental Scrvic'.!~ 900 Oakesdole A·,·enue SW Renton. WA 0eo55.121'.l FikNo. Fik Name: Application Date: Revision Dme: CO\'UITIO:\'S OF ,\Pi'ROVAL LOJS0016 Ch:1u Short Pbt !\fay 2, 2003 January 30, 2004 This short stibdidsion is gramed preliminary approval subjcct to lbc following Cuncliti.ons of ApjH"OYal. These conditions arc based on a field visit and rnrrent_infor_mut_ion the ,~ppl1:~nt has provided about the sJ1ort subdivision property. Ocrasionnlly, m sultsfymg the Cond1t1ons of,\pproval, a more ddinitivc Lmd use limitation of the propert~ nrny be re,·c,:kd. !\'.e:v infurrn::illon (such a~ final Health approval or sensiti1·e UP;!US re1·1ew) may require addnmnal cunditions and may n:duce the number oflots. ,_- G. IL The fv!lowing noks sli,dl k 'iliuwn 0111b: fin:ll ri.:cunled slwrt subdivision: I) \\':'.rni.ng: King county lws !HI l"L'Sj)OI\Sibility to build. i:11prove, :n,rni_ca.m or ot11~·111 1sc ser"l'icc th\.' )1r11·ak roads con(;; i11L·d within or pro 1·1dmg sc1T1,·.: lO the µrojl,:rty d~·c,cJibed in this sl1on ,ubdi,-isio 11. . .\II privme eas<.:111\'tl!S and/or !rcicts '.Ob,; 111aintaint'd. rq,,,in:d, ;in,l'or n:b_udt ~y the ~1111ers ofihe p:ir~·L·ls lu1·ing kga! a('ccss tL\.'refrorn and '.hl'ir heirs, ass1g11s or sui.:c<.'S50<>. unless a11d until such rn:1ds t1re unproved io Ki1w Cou 1 -, I· J ' • , .• _0 n Y 01d11t . .ll', s c1nu are dc:dicatt:d :mJ ,iccepted by Krng Count) tc'I niainli.'Jinnc<: ,\ll utiliLies \\'lt!1;11 n1u11u-·,j rl 1 1 · -·I ·1 •-· · · i ~cc g 1t,;-0J-11.1y s 1cu ve Jlll'IL:lkd \\"itilin ~ tlancl1ise appro\\:d by clie K11,g Coumy Cuu11cil ;11·ior to final shon subdiYisi(Jll · recordmg. All restrictions, easements, tract:;, and their purpose sh.ill bl! shown on tbe final recorded short subdivision. Final apprnYal will be granted aft..:r eompliancc 1.-ith the Conditions of ,\1:rroYal. Key codi:s .1nd guiJdirn:s lwve bo:en noted 10 pro\'ide guidance in preprtrmg Lhc n:quw:d pl:ms and other documents. Comp! innce with ,ome of the following conditions will rcqulre that engirn.'tri11g plans be prep.ired by a proP.:ssional dvil engin..:cr licensed 111 the Stale of\Vashington. 5. Building :111d Construction Standanh (Title 16) 1. Title 19A Grading. Tile applic,1111 shall comply \\'1th all app!ic-able pro\·isions ofKCC 16.82. A. The short ~ubfo,ision shaJI comply \1 iili all pruvisions of Title 19.\. 6. Fire Code (KCC 17) fL The final rc\"icw process must be cornple!ed prior to recording of the ~1io11 sub<li1·isiorl. The Uo.:partment of Do.:1·0.:lopment :mt! E11>·iro111m.'J1tal Scn·ices (DOES) sti"ongly recommends the final SJ1ort Plat be submitted at least one year prior !O the ~};;i.\ration date of!li<;:J@kf.!. The Final ShOii l'lat sl:bmitrnl packag~ iutludes: St"ction 902 of the 1997 Edition of L'11iform Fire Code The applicant shall obtain the :1pp:-01·al of the Klng County fire Protection Engineer for die actequucy of the fire hydr,1m, wal\:r main, and fire flow s1anJards ofKCC 17.08 prior to recoding of the lots 1. A surre)'ed map puge (four sets) including lot area closure calculations; 7. Zoning Code (KCC 21A) 2. final Jieal!b approval from rhe King Couuty Health Depa1iment (difli:1rnt from prdimimiry health .ipp1·01·;il); J. A cunem shon plat Cl:rtificate and supporting docum<!nts (easements, etc.); 4. Payme1\l of tile Fina! Short Pim submittal fee; 5. A copy of this lcttl'r (prelirnina1·y :1pprova! letter). A JicenseJ land sur\'eyor shall be hired to prepare Li10c find short subdil"ision documents. These documents shall comply with all of the following conditions for final approval: C. All persons lrnYing an ownership inkrest in the subject property are required to sign the final short subdivision. D. Ifrnodilic11tions to the oipprovcd pn:li111ina1y site plan (Att:idunent 1) are needed to :iccomplisb engineering design or Jina! ::;hort plat, then a rc\'iscd preliminary s!(e plan shall be submitted 10 DDES for reriew and c1ppro,·,il. The n.:vised site plans shall be submincd with the engim•ering plans or the final sho11 plat ~Libmitrn!. - 2. Surface \\'ater .)/an:tgrn1ent (KCC 9) 1998 King Couut}' Surf.ire Waitr Dtsigu .\l.111ual (SW!).l',I) A. This sl1ort ,mbdivision proposal is subject !o full Drainage Review per section 1 .1.2.3. Final short subdh·ision approval shall require full compliance with drainage pr'Ovislons and storm drainage rcquirerill'nts of this S\:ction. Compliall(;t may result in reducing the number anJ/or location of lots shown on tl1e approYed prdiminary shurt subdiYision. The conditions outlined below are site-spec.:itic drainage conditions: (I) Cort· Requireu1cnt #I -Discharge al the Natura) Locntion (2) Core Requirement #2 -Off-Site Analysis (3) Core Hequircrncnt i/3 -Flow Control (4) Co.-c Rcquin•nH.'nt #4 -Coiweyatl(.'e System (5) Co,-c lfrquirnucu1 #5 -E,osiou & Scciimcnte11iou Conlrul (6) Core RcqLJircrncnt #6-!\fointcnancc ;11,d Op,:mtion (7) Core Rc(Juir·eim•nt f/7 • Fimmcial Gl1ar:miecs & Li:ibility (8) Cun• Hcquirelllt'Hl #8 -W11tcr Quality (SJ) Spt'dal Requirement #J -Other Adopted Reguircmrnts D. A professional einl engineer lice!lsed in the State of Washington sliall prepare a Technic;d /nformor1on Report and/or enginec-ring plans per Chapti.:r 2, of the 1998 King County Surfuce \V(ltcr Design .\l;rnu,il. 3. Health (KCC 13) This project is exempt from further Kiug County Heath Deparltnelll revii.:w. Hov,·cver, if i1111nn·cmc11ts fire required from the Se11·cr amL'or thc \Valer Dtstrict, thell ,·eritlention sball be required from said District(s) tlwt the improvements !Jave been bonded and/or installed, prior to final recording of tl1c short plat. 4, Road Standurds (KCC J-1) 1993 King County Road Stundards, Ordi1rn11ce 11187 Film] sl1ort SLibdivision approval shall require full compliunce 1\ith the proYisions set forth in the King County Road Standards including engineering plans for all ro.id impro\'emc11ts. The engineering plans shall be prepared by a professional ci\"il engineer licensed In the St:i!c of Washington. DOES strongly recommends the ErH!.inel'ring Plans be submiucd at least lwo_}"t'ars m:i.9I to the l'..:.\piration date of the p.rgj_r\j. A. That JJl.lrtion of'!he North half of SE l 72"J Street adjoining th•.: suOject prope11Y s!rnll he impro1·ed to an urban Sub-access standard pcr KCJ.'.S SL'Ction l .03. B. That 11ortion of tile East half of 106:h A\"enue SE adjoining thC' subject prope11y · shall Uc improvo;:d to an urban Sub-access srnndard per KCRS Scction 1.03. C D. A. Ol!nsity and Dimensions (KCC 2JA.12) All lots sh:i.11 meet the density and dimensions rcquire11ients of the R-8-SO zone classification or sball be us sl1u1rn on tlw face of the approYed prelimi- n:iry shon subdi\"ision, whicl1ever is lar!.!er. ;,.1inor n.;,·isiuns to the short subdivision, which do not result in subslantfal changes amlfor do not create ndditional Juts may be approYed at the discretion of LUSD. f3 StrectTrci.:s(KCC2lA.16) Stre~t tr,·~s shall be prO\·id<:d along that po11ion ofihe right-of-\\"ay fur lOG 1" 1\l"cm1c Southi:ast and Sou1lie:1st J 72"d Strcc-t ;1butting the subj-cc! property. pltrsu:rnt to the proYi.:,ions of KCC 21 A.16.050( l:) :md KCC 21 A.16.190, unless nisting tree's are shown to bi:: equiv:1k:ll to tile rcquire111en( of Code. Sce rwte lwiow. Tile req11ired street lrees shall be cksigneU as to loc,llion :md sp:1ci11g un the final plan submitL:ll. Tbe street t1·ccs 111ust be installed and i:isrwclL'd. ,,r a performancc bond Jl03tl.'d, p1·ior to rl.'i::ording of tile plat. !fa J.'Crforn1:1nce bond is posted, the Sli"L'Cl trees must be i•:stalled and inspected 1\ ithin u11<: year of recording o!'thl' p!;,t. At the time of inspect1un, if the trees an: f;-11:11d lq li,.: installed per the ;1pp1\i1·ed plan, a rnaintcmmcc' bond must be ,ubmiucd, ot· !be pcdOrm:mce boiid rcpl.ice<l with a m:rnnenancc boud, and held for 011c yenr. After um.' yc'ar, thL' maintenance bvnd may be released after DUES has completed a second inspection and detami11cd that the trees han:: bc1:n kept he,litby and tliri1·lng. J\'OTE: KCC 21 A.J 6.050 1.aud~caping -street front:1ges. The a\"Crage \\"idth of perimeter landsc2pi11g :dong street frontages sl1:lil bi= prodded as foJJows: for single-family subdiYisions: a. Trees shall be plan:l'd at tl1c rate of oni.: tree for every 40 feet of frotJtagi.: along a neighborhood collei,:tor scrtl'l or ;merial street. b The trees sl1all be: 1. Locate_d within 1!1c sticet right-of-way ifpcrmiucd by the cus1od1:1[ state or lorn! al!cncy· 2. No mor,; than 20 fed fro~n the' street right-of-ll"ay line when loc<Hl'd within a lot; 3. t\Ta_intained by the ~djrice11t landowner tm!ess parl ofa Courny mamtenanec program; and 4. :\ ,;pecics .ipprovl'd by the County if located within the street right-of-way :md compatible with o,·erhead utility lines. c. The trees may bc spri.:Jd at irregular inter\'als in order tu ~cconmi:idute sight diil:rnce requirc·mci1ts for driveways and 1J1terscct1ons. 2. KCC 2J..\.16.190 Fin:rndlll gullr.-tn!ees. Fi:1ancial ~uara11teeo sh.1.ll bo;: requiri.:d consistent with the pto\·i:;ions of Title 27.-\. ~ · Sig11.ifil·11Ht Tree ~drnt/011. KCC 2JA.38.:230 \1·hicli ,1;1pli<:s to tile siw, a detaile,! tree fft<:1,1~10n pi:rn ,h,dl be submitted witli th~ cnginccring plans for the sub_1ed plat. ! hi.: tree retention plnn (and cnginc'..'ri!lg phlns) sli:ill be consist..:nt_wnh ciic re~uir:menls of KCC 2 l A.3S.230, ,is well as the conceptud tree r,:tent1_or1 pl:m _,.,foch ts pnr1 of lhe hearing record for this project. ;"Jo ck:mng ot 1l1e s.u.bJect prop~ny is permitted until tl1<: final tree rc1c:nion plan is approved by LL,SD. Flaggmg and temporal)' frncim! of trees to be retaind ~hall b~ pro,·id~d, con;isten! w_ith KCC 21A.38.23UJ3.i. The placc·mem of 1mperv1ous surbccs, Jill m:i1cr1al, 1:xea1·.ition work, or :he storn!!e of constrnctiou r'.1:11erials is prohibited 11·ithill the fenccJ cirl'as nrot;nd prcs..:rl'eJ trl'es, e;-;cept Jor grading work permitkd pursuant to KCC 21A.3S.230B--id(2), A note shall be placed on 1hc final plar indicaiing tlwt the trees sllo\\'n 10 be 1•:ta1n..:d on th<: trc~ ie1i.:n1ion plan sli:111 be rnaint,!11,ed tiv :he future 011nu~ of lilt: 11roposed In:~. ,·u11sisknt with KCC 2JA.3S.23UH6. ·('.',/ote that the tree rc'le_ntwn plan :J:,ill L1c inc!udcd ;_1s p:1n oJ" the final ,:ngrnc~ring pb:1s i'ur the su_bJt'e[ pLtt.) lJ 1hcrL·_~grnli,·;1~1t trcl'S as ddl;t':'.1.Qv the S1Jccd Cher!av f2l.2r1_(,:l un !lie. :i1tc: illL'll. this.Wl!!it":c'!lli.:nt does nut ;iJ?;:_l):_:. --·----- :ri1e cx:~1it:g hou~e ~ha:1_ bc remo,·t·d or dcmolishL'd p~ior m till' ti 11 al ::pprornl .ind rL'COrdmg. ,\ demoln1on pcnrnt ~lwll be obtnined prlor to demolition. C. Provide 35' par\:d radii at 1lie intersection of 106 1h Avenue SE c.nd SE 172 Street per KCRS Seetion 2. lO. Dediculc a 25-foot propeny Ii11c r:idiuo at the intcrsc~'lion of !OG 1h Avenu~ SE and SE J 72"J Street pi.:r KCRS Sec-tivn 2.10. "· lfo:id 1\[itig;1tion l'ayrnvnt Sy~tl'lll D. Existiug rnadsidc obst,1dc(s) shall be rl'lucated lo pro,·ide a minin;um clcar.mce of 10 frct from the edge oftbe trnl'cl lane lo the ob,;wck(s) per KCRS Section 5.11. E. Pri,·at,:; access lO Lots 2 and 3 shall be shown as a joint-tis..: dri\·eway trni::t per KCRS Section 3.01. The tract shall be an undi\·ided ownership to tile lot~ it serves, and tbe lo! 01\ners sl1;dl be responsible for its maintenance. The tract shall bc 20-foet wide \\"ith a IS-foot-wide p:1\"ed surl~ice. The-1rnct sh.di be a mini111um of20 fcet in length. UTILITY CONFLICT NOTE: CAUTION: THE CONTRACTOR SHALL BE RCSPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION AND DEPTH OF ALL EXISTING UTILITIES WH£THER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE @ 1-800-424-5555 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSING TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE NOT GUARANTEED AND AHE SUBJECT TO VARIATION, LEGAL DESCRIPTION LDT 13, BLOCK 4, AKER'S FARMS ND, 5, ACCORDING TD THE PLAT THEREOF, RECORDED IN VOLUME 40 OF PLATS, PAGE 27, IN KING COUNTY, \,/ASHINGTON1 EXCEPT THE \,/EST 170 FT, AS MEASURED ALONG THE NORTH LINE THEREOF; AND EXCEPT THE NORTH 60 FT, OF THE REMAINDER. 9, l(). Thc applicant shall comply ll"ith Ro:1d Jvlitigation Payment System (MPS), by puying tile rcquired J\!PS fre as detennintd by King County Depurtmenl oC Transportution, plus au adrninistr:iti\'e foe. Thc :lpplicant has an option to either: :\. Pny tile },JPS fee a! final ~hon subdivision recor<liJJg and the /\ll'S adrni11istrntive fee at final s\ion subJil'ision application, or B. Pay 1hc MPS fee al bL1ilding permit issuance and !lit /'v1PS administrati1·e fee at the time of building permit application. lfoption ,\ is chosen, 1!1en the following note shall Lie sbown on the final short pbt: .'\[PS FEE SOT!CE: All fres required by King County code 14.75, J\foigntion Payment System (MPS) lla\"e bccn paid. If option B is chosen. then the following note shall be shown on tile final sho11 pl~t: .\!I'S FEE i\'OTlCE: This short pbt is subject to King County Code No. 14.75. King County Ro:id 1\1itig;itioB 1'aymcnt System (:\!PS). Tile MPS fee~ plus the :-.tPS administrnli\e fre s]1all be p:iid m the tinK' of building pnmil applicallon at the r:1!c in cffrrt at th.JI time. State Environuiental P0licy ,\ct (S.El',\) This short st1bJil·ision was cxc:npl from the prol'ision oftli1: St:1te E1wironmcntal Policy Act (SEP:\). Othl'r Cun~iderarions Preliminary approl'al oftbis ,1;1plicmion does not limit the applirnnt's responsibility to t,b1;1i11 :i.ny reqrnred permit or licens~ from \he State or other rtgulatory body .. Tl1is m,:y include obt.1111illg a for<:st praetlce pm nit from the Wa.,l1ingtun Stule Department of I\:1turnl Resourc.-es for tree remonil. INDE>< Co\JER I)Rf'\1"1/",GE. ~ Rot,,D PL/\N j 2 3 4 1'-lDTES { DET/1. 1 l.S TE.S.C.P. TREE. PLAN l/t NOTS: u .s. P.s. L£C/"( 11 D 1---Ji ON p ll.£. Ai, /<I N c;, C()uNl'-t DDEs. VERTICAL DA TUM, NAD 83, PER \,/SDDT GEOGRAPHICAL INFORM A TIDN REPORT BENCHMARK, CONCRETE MONUMENT IN CASE\,// A BRASS PLUG~ THE INTERSECTION OF SR 515 & SC 180th ST, ELEVATION = 402.09' PER \,/SllDT GEOGRAPHICAL SERVICES SURVEY MARK REPORT, MDNUMCNT LD, 112606 AND DESIGNATION llIS 1765, ---------___.__ _________ _ --___J_ Vici n it y M a p SW 23.90 ST >--U,J !.... .• -·-------::} :';: I -er -I > i ' g I I ST > I SW 29TH ST -----·--- H Soils Map Notice Required Controctors shall notify operators who maintain underground utlllty lines in the area of proposed excavation or blasting at least two business days, but not more than ten working days prior to commencement of excavation or demolition in accordance with RCW Title 19. Names and telephone numbers of the operators of underground utility lines in this project appear below. These numbers shall also be used to serve in an emergency conditions as required. Phone SOOS CREEK WATER & SEWER DIST. (253) 630-9900 Sanitary Sewer SOOS CREEK WATER & SEWER DIST. (253) 630-9900 Water District PUGET SOUND ENERGY ( 425) 454-6363 Gas Company PUGET SOUND ENERGY (253) 395-6915 Power Company Call Before You Dig DIAL-A-DIG 1-800-424-5555 Notes 1. The Developer is required to notify the Land Use Services Division, Land Use Inspection Section (206) 296-6642, three days prior to the beginning of construction for a preconstruction conference and specifically request inspection before beginning: A. Installing siltation and erosion control measures B. Clearing ond grubbing C. Earthwork D. Installation of any underground utility E. Before placing subbase, base or paving surfaces F. Installation of any forms or placing any concrete 2. A permlt must be obtained from the office of the Resident Engineer, Washington State Department of Transportation, before any construction is started on any existing state route. 3. A Hydraulic Project Approval (HPA) Permit must be obtained from the Washington State Department of Fisheries prior to any work when required. Bonding Information Restoration Bond Amount $ _______ _ Performance Bond Amount $ _______ _ Site Plan Approval Approval of these plans is for construction of road and drainage irnprovements, site drainage & grading and temporary erosion control in unincorporated King County only, These plons do not authorize any other utility approval or improvements proposed in any State right of way. Site plan approval is void if the commercial building permit has not been obtained or renewed within two years of approval. Subdivision plan approval is void if the final plat is not recorded prior to the preliminary plat approval expiration. A.SSESSOR S NO.: 008700-0280 PRO RATA SHARE ASSESSMENT ANALYSIS (County Use Only) Section Township Range Tax Parcel Number ? 9 I 213 I I Ol 4 I I o IO I B 17 I o 10 I o 12 I BI o I Site Location is within the _ GR_EEf':!J31VER drainage shed(s) Pro R<Jto Share Assessment(s) are: D rfoqutred D Not Required frorn the site due to development Peak Runoff Assessment Rate($ Pcok Volume Assessment Rate(J: for increased storm water runoff. ) per c.f.s. lncreoses.(10 year, 2 hour storm) ) per Ac. Ft. lncreases.(2 year, 2 hour storm) AGREEMENTS, PLAN REFERENCES, PERMITS ETC. (To be completed by Consultant) Preliminary Plat Approval/Permit Issued Date: MARCH 12, 2004 Expiration Date: other Related Permit Numbers Received: Right-of-Way Use Permit Grading Building/Structural Other ______________ _ Board feet of tree removal on site: MARCH 12, 2009 NONE Cubic yards of material hauled on/off the site: Is this a erosion sensitive area site? (Yes/No): __ N_D __ _ Note: If "yes", a Highly Sensitive Site Erosion Control Supervisor is required. See ESC plan and TIR for details. f--------------------------------------' Ernergency 911 Police-Fire-Rescue RECOMMENDED FOR APPROVAL (To be completed by King County) Date Engineer Plan Reviewer Engineer Supervisor Traffic & Planning Engineer Sensitive Areas Structural Review Engineer Other APPROVED FOR CONSTR.UCTION DEPARTMENT OF DEVELOPMENT & ENVIRONMENTAL SERVICES Date Q_ 00 " L L Q) 0 OJ Y:: >-, " " s ··" > L L o> QJ :J L C (.) U) ow D 12 @) King County, Washington James H. Sanders, P .E. Development Engineer PROJECT CONTACT INFORMATION ___ H_A_M_IN_J_I_C_1I_A_U __ ____,.( 425) 643-3993 Name 4101 150th AVE. SE 98006 BELLEVUE, WA. Address and Zip Code Phone D A Partnership 81 An Individual ___ H_A __ J.,f_I_N_H __ CH_A_U __ __LC 425) 643-3993 Name 4101 150th AVE. SE 98006 BELLEVUE WA. Address and Zip Code Phone D A Corporation D A Partnership 13 An Individual -==-===---=-=--'--'=-'-===-=-:__:::_--:,__(-2 53) 850-09 34 JAEGER ENGINEERING Name Phone 9419 s. 204 PL KENT 98031 Address and Zip Code L (j 0 (/) z '> L -Q) a:: Q_ ::J w (J) '----w L Q) z Q) C - CJ) C, C w z '----+-' w 0 Q) +-' a:: __c 0 ill L <( (j C (J'l w (/) Q) <! 0 J t\) (\) 0 (J) r- (J) O:'. 0 w m 2 L Q) ::) __Q z E w :::J __J z LL >--, +-' (J) ,_ > w 0 +-' 0 0 <( Qj CJ ~ ii; ~ .q 0 ....., Cl;) '*' 0) 0 C\1 • .q~ ....., ;:j • 0..., en q 0) ~ .... '*' 0) (0 .... 0 0 en Ct? 0 ~ L QJ __Q E :::J z _.., 0 Q) ·~ 0 L o_ ..;- I") OJ 0 I 0 I{) OCl w CL ci w (.') w <( -, -, (/) w ::;;; <( -, Q) C 0 __c Q_ L 0 +-' 0 C -u L 0 0 () --1--' 0 Q) ·~ 0 L Q_ 0 z _µ C Q) E Q_ 0 Q) > Q) 0 License/Seal Sheet 1 of _:;J,___ (ci') [1!'il = cq ~ = 0 w "" § = ~ [1!'il CD @ > ~ 0 J1l!1J = @s ' ',,- . ' ·, 1+00 SCALE: 1" 1 " - 10+00 SCALE: 1" 1 " f-C (/) 3 x'-- WO'.'. VARIES 5' SIDEWALK 0.5' 2% 20' HORZ. 5' VERT. 20' HORZ. 5' VERT. 30' SE 2+00 172nd ST. (URBAN SUB ACCESS) 11 +00 106th AVE. SE (URBAN SUB ACCESS) 1--z w ::e :,: w '--> <( O'.'. (L G' G' VARIES 12' ----,-:-·----· '!.> 4" THICK L----\--\ CONC. WALK VERTICAL CONC. CURB & GUTTER CROSS SECTION SE 172nd ST. & 106th A VE (URBAN SUB ACCESS) N.T.S. 2" CLASS "B" ASPHALT CONCRETE 1.5" COMPACTED DEPTH CRUSHED SURFACING TOP COURSE 5" COMPACTED DEPTH SE\ CRUSHED SURFACING BASE COUSE -ADDITIONAL GRAVEL MAY BE REQUIRED DEPENDING ON SOIL CONDITIONS A PORTION C)F THE SW 1 /4 OF SECTION 29, TWP. 23 N., F~GE. 4 E., W.M. -375 3+00 12' RCP t INV=369.7 5" I-1/4" EDGED I "f1 1" --1--~-Gf/OOVE \ 2.0% t "* I . ' ' ' , ' 6" ' ' I ' , 5.0% __ ! "--, .. . ,, ' f T ,, ' " ' ' . 4 ' I /8" I r-----·- *NOTE: TOP OF CURB @ DRIVEWAYS CEMENT CONCRETE VERTICAL CURB AND GUTTER NOT TO SCALE NOTE: F'ER KCRS SECTION 4.1 OF, A 1 INCH FULL WIDTH OVERLAY SHALL BE REQUIRED ALONG THE PROPERTY FRONTAGE OF 106th AVE. SE AND SE 172nd ST. APPROPRIATE REPAIRS TO THE EXISTING SUBGRAOE, BASE MATERIAL, SURF ACING AND PRE-LEVEL MAY BE REQUIRED PRIOR TO PLACING THE OVERLAY. THE OVERLAY MAY BE WAIVED ONLY UPON WRITTEN REQUEST ANO AFTER AN EVALUATION OF PAVEMENT CONDITIONS AND /OR CHANNELIZATION REQUIREMENTS HAS BEEN COMPLETED BY THE COUNTY ROAD ENGINEER OR DEVELOPMENT ENGINEER. FLOW LINE TO BE r-DIRECTED TO CATCH BASIN AS SHOWN ON PLAN w 20' w s,...._ ____ r--TRACT -s § ·, '1 / 18' , 1 § --. 1·A-:-ci. PAVEMENr I --- THICKENED " I 3 I '1 EDGE CURB '-~ -1 , -I f I' ! 2% :s::::::s:::::s:-.:::s.=s:=..c~/1/'-~11<::-//.0/,/// 'll.::$-ll/:;;,'-l/,<-0.~-.::s.=.::s:.:::::s:::s.=-~-s=:::==:s=s:;::::::s ~ BL_DCk 4 Al<ER 1 S F AR~IS ND. 5 VOL 40 1 PAGE 27 T t' .. ,-°, • • ••• < ·. ~,:;,;;:-.; •. ~~;/k.,i,;f;iii~;;;;.;;,: , I m::.-::.-m..:::-!77~'717;;.-~ ...._, " -- 0.5 @ BACK OF·-• 0 2" COMPACTED DEPTH WEDGE CLASS "B" ASPHALT LDT 12 300.01' CCAL.C) 300' CPL.AT) 130.01' 1 1/2" MIN. COMPACTED DEPTH CRUSHED SURFACING TOP COURSE 2 1 /2" MIN. COMPACTED DEPTH CRUSHED SURFACING BASE COURSE ADDITIONAL TREATMENT MAY BE REQUIRED DEPENDING ON SOIL CONDITIONS. SEE SEC. 4.02 "A" JOINT USE DRIVEWAY TRACT N.T.S. J' THICKENED EDGE ASPHALT DETAIL NOTE: 1. TRACT "A'. IS A JOINT USE DRIVEWAY TRACT TO BE JOINTLY OWNED AND MAINTAINED BY LOTS #2 AND #3. 2. EXISTING WATER MAIN SHALL BE LOCATED BY POTHOLING PRIOR TO INSTALLATION OF DRAINAGE SYSTEM. GRAPHIC SCALE 20 O 10 20 40 ~ ;;,rm' ~r·::::r ~THI) t'll'lt717'.T ( IN FEET ) 1 inch = 20 ft. L_OT 13 80 Fr 72 '0 1'W77~ NOT TO SCALE King County Deportment of Development and Environmental Services APPROVAL FOR SITE CONSTRUCTION Review Engineer EN GR COMP Dote Senior Engineer ENGRCOMP Date DEVELOPMENT ENGINEER APPROVAL Date Comments: RE\>1SIONS: . f,i;:V. PER CTY. -6l;IMENTS 10-1-0 1. F,EV. PER CTY. co~iMENTS 10-20-08 ~ ~ N ~ ~ ~ ll..; ~ ~ ~ SC,: 5 ~ N <c ~ c:, 0 '-< ,-,: ...;i "I< ts "'l c:, ;'."1 en i:... ~ -. ~ ~ ~ "' Cj 0 w , 0 "' !L "'l b <c 0:, ~ c:, 0:, ~ c:, "'l • o:i I ~ 0:, "'l ;:.: "I< ...: :"1 <c ~ ~ ;:>.::-., ...., l(') c:, • Cl) ~ l(') f:3 ~ -. :::. -. ::l@ ~ c:, '-'l ~2§~ 0., "' z <( u :J IL IL <( DATE: 3/16/07 SCALE: 1" = 30' DESIGN BY: JJJ DRWN. BY: JJJ APP. BY: FILE No. SHEET 2 OF 4 ' \ 1. All construction shall be in accordance with t11e King County Code (KCC). Road Standards (KCRS), and the King Cou,ilY Council's conditions of preliminary subdivision approval. It shall be the sole responsibility of the applicant and the professional civil engineer to correct any error, omission, or variation from the above requirements found in these plans-All corrections shall be at no additional cost or liability to King County. 2. Tt,e design elements within these plans have been reviewed according to the King County Department of Development and Environmental Services (DDES) Engineering Review checklist. Some elements may have been overlooked or missed by the DDES plan reviewer. Any variance from adopted standards is not allowed unless specifically approved by King County prior to construction. 3. Approval of this road, grading, and drainage plan does not constitute an approval of any other construction (e.g. domestic water conveyance, sewer conveyance, gas, electrical, etc.) 4. Before any construction or development activity, a pre-construction meeting must be held between the DDES's Development Inspection Unit, the Applicant, and the Applicant's Construction Representative. 5. A copy of these approved plans must be on the job site whenever construction is in progress. 6. construction noise shall be limited as per King County Code (Section 12.88); normally, this is 7 a.m. to 10 p.m. weekdays and 9 a.m. to 10 p.m. on weekends. 7. It shall be the applicant's/contractor's responsibility to obtain all construction easements necessary before initiating off-site work within the road rights-of-way. a. Franchised utilities or other installations that are not shown on these approved plans shall not be constructed unless an approved set of plans that meet all requirements of KCRS Chapter 8 are submitted to the DOES's Development Inspection Unit three days prior to construction. 9. Datum shall be KCAS unless otherwise approved by ODES. 10. Groundwater system construction shall be within a right-of-way or appropriate drainage easement. but not underneath the roadway section. All groundwater systems must be constructed in accordance with Section 81 3.02 of the APWA Standard Specifications. 11. All utility trenches shall be back filled and compacted to 95 percent density. 12. All roadway subgrade shall be back filled and compacted to 95 percent density (WSDOT 2-06.3). 13. Open cutting of existing roadways is not allowed unless specifically approved by ODES and noted on these approved plans. Any open cut shall be restored in accordance with KCRS 8.03(8)3. 14. Tt1e Contractor shall be responsible for providing adequate safeguards, safety devices, protective equipment, flaggers, and any other needed actions to protect the life, health, and safety of the public, and to protect property in connection with the performance of work covered by the contractor. Any work within the traveled right-of-way that may interrupt normal traffic flow shall require at least one flagger for each lane of traffic affected. All sections of the WSDOT Standard Specifications 1-07.23 · Traffic Control, shall apply. DRAINAGE NOTES 1. Proof of liability insurance shall be submitted to ODES prior to the pre-construction meeting (KCC 9.04.100.D). 2. All pipe and appurtenances shall be laid on a properly prepared foundation in accordance with WSDOT 7-02.3(1). This shall include leveling and coinpo.iuting the trench bottom, the top of the foundation material, and any required pipe bedding, to a uniform grade so that the entire pipe is suppor\<1d by a uniformly dense unyielding base. 3. Steel pipe shall be galvanized and have asphalt treatment #1 or better inside and outside (KCRS 7.03). 4. All cl1 ainage structures, such as catch basins and manholes, not located within a traveled roadway or sidewalk, shall have solid locking lids. All drainauu structures associated with a permanent retention/detention facility shall have solid locking lids (KCRS 7.05). ,,,-RIGHT-OF-WAY LINE 3' ·-o· DRIVEWAY CURB (SEE s~c. FIG 3~01 2) (j) 3/8" EXPN\SI01\J JOlelT (,~p ) D::.TECTABLE WARl\11,\JG PATTERN (SEE JE:Tf\lL} - SIDEWAcK 4 ,. (2\ '-"1, ' . ';2 . rc~---.1 , - ll' .. - M',N. : ! I .-I! ,, I I . ', CURB RAMP 1 A (0 CUT CURB, Oc1 CURB ANO GUTTER C ROSS'NALK NOTES: 1. SEE SEC. 3.04 K.C.R.S. FOR JOINT REQUIREMENTS. 2. ROLL GUTTER TO MATCH POSITIVE SUPERELEVATION. 3. SEE DRAWING NO. 1-006 FOR CONFIGURATION OF FILL & WALKWAY BEHIND CURB IF REQUIF1ED. 4. FOR INTEGRAL POUR CONSTRUCTION, 1/4" EDGED GROOVE MAY REPLACE EXPANSION JOINT AT INTERFACE BETWEEN THE CURB AND ADJACENT SIDEWALK. 5. SEE SEC. 3.03 FOR EXTRUDED CURB ANCHORAGE. SIDE'NALK PL.ANTING STRlf=> VARll::S MATCfl EXISTING DRIVEWAY GRAD!: SECTION A-A CEME,\T CQi,'CFJETE DR1\/E'NAY 5" THJCK 9'-o" 76" 2'-1" 5'-o" ( ANCHOR BOLT PATTERN PER NDCBU PEDESTAL TEMPLATE 1 -?T 3/8" x FULL DEPTH 6"r I rT I EXPANSION JOINT r-1 --.-----.--.c. CJ ,' j ' ,• , . •' , , ' (Q I SID£ VI EW ' . ? ? 10' o" -I I I i 2'-o" r----- I 10'~0" r ' 2'-0" j -~~ -..ii·--···-...-l I ' ' ~ 2.0' MIN FOF, TRUNCATED ~ ® }~ DOME SECTION PVMT. TEXTURE --- CEMENT CONCRETE SIDEWALK AND RAMP NOTES ·" MIN. SECTION A-A 1. SEE SEC. 3.02 FOR SIDEWALK WIDTHS. MATCH EXISTING OR PROPOSED SURFACE 2. SEE SECS. 2.02 AND 2.03 FOR PAI/DAENT AND SHOULDER WIDTHS. J. SHOULDER SHALL BE SURFACED AS l<EOUIRED BY SECS. 3.07 AND 4.01. PAVED SHOULDrn SLOPE SHALL MATCH CROWN SLOPE OR 0.02 FT./FT. 4. SEE FIG, 3-001 FOF, CURB ANO SIDEWALK JOINTS. , REV. PER C,_._T-'-"Y.~1 OMiJEITTsio-1-0- C) z er w w z 0 z w er w 0 w § <( @) RAMP SHALL BE TEXTURED USING TRUNCATED DOME PATTERN. (SEE FIG. 3-01 · -~ ) DETECTABLE WEARING PATTERN SHALL BE YELLOW IN COMPLIANCE WITH WSDOT STANDARD SPECIFICATIONS 8-14.3(3) - . 6. THIS DETAIL APPLIES TO ROLLED AND VERTICAL CURB ROADWAYS. - SIDE1YALK 'I'RANSITION RAMP N.D.C.8.U. CUTUR MODEL CB-6 OR EQUAL~ ---~~ . ' ~ 5. All c,itch basin grates shalt conform to KCRS drawing numbers 2·013, 2·018, 2·019, or 2-020, which includes the stamping "OUTFALL TO STREAM, DUMP NO POLLUTANTS" and "Property of King County" (KCRS 7.05). 6. All driveway culverts located wlthin King County right-of.way shall be of sufficient length lo provide a minimum 3:1 slope from the edge of the driveway to the bottom of the ditch. Culverts shall have beve!ed end sections to match the side slope (KCRS 7.03{L), Drawing No.2-001). ii I ' C) _I 'D I ~-~ I ' ~ rT " -"' rr • --·- ~ ~ [;J 0::: VJ ~ 7. Rock for erosion protection of roadway ditches, where required, must be of sound quarry rock, placed to a depth of 1 foot, and must meet the following specifications: 4". 8" rock140%.70% passing; 2"· 4" rock/30%·40% passing: and -2' rock/10'%-20% passing. ln:;tallation shall be in accordance with KCRS 7.02(8) drawing number 2-024 8. Drainc1ge outlets (stub-outs) shall be provided for each individual lot, except for those lots approved for infiltration by King County. Stub-outs shall conform to the following: a) Each outlet shall be suitably located at the lowest elevation on the lot, so as to service all future roof downspouts and footing drains, driveways, yard drains, and any other surface or subsurface drains necessary to render the lots suitable for their intended use. Each outlet shall have free-flowing, positive drainage to an approved storm water conveyance system or to an approved outfall location. b) Outlets on each lot shalt be located with a five.foot-high, 2" x 4" stake marked "storm" or "drain". The stub-out shall extend above surface level, be visible, and be secured lo the stake. c) PipEJ material shall conform to under drain specifications described in KCRS 7.04 and, if non-metallic, the pipe shall contain wire or other accept..il,le detection. d) Orainnge easements are required for drainage systems designed to convey flows through ir,dividua! tots. e) The applicant/contractor is responsible for coordinating the locations of all stub·out conveyance lines with respect to the utilities (e.g. power, gas, telephone, television). f) All individual stub·outs shall be privately owned and maintained by the lot homeowner FIRl HYDRANT OR UTILIT'f POLE LUMINAIRE SIDEWALK NEXT TO VERTICAL CURB ~ PLANTING STRIP ~ ~~ l5 o' Mlt:l. SIDEWALK -· CEME.'H CONC. SIDEWA: _ _K R/1);1.? IYP.:: lf\ MIN. f,1AX A 1 5/8" 2 3/o'' . B 5/8'" -1 1 /2"" C 7/16" 3/4" D 7/8"" ._1 7 /1 G' A " nl ' © ®-@) PLAN C D ELEVATION PLAN LAYOUT l DETECTABLE WARNING PATTERN DETAIL NOTES 1. PLACEMENT OF GRATINGS, ACCESS COVERS AND OTHER APPURTENANCES SHALL NOT BE LOCATED ON CURB RAMPS, LANDINGS AND GUTTERS WITHIN THE PEDESTRIAN ACCESS ROUTE, '2) RAMPS SHALL BE TEXTURED USING TRUNCATED DOME PATIERN (SEE DETAIL THIS PAGE). DETECTABLE WARNING PATTERN SHALL BE YELLOW IN COMPLIANCE WITH WSDOT STANDARD SPECIFICATION 8-14.3(3) 3. RAMP CENTER LINE SHALL BE PERPENDICULAR TO OR RADIAL TO CURB RETURNS UNLESS OTHERWISE APPROVED BY THE COUNTY ROAD ENGINEER. 4. RAMPS SHALL BE CONSTRUCTED AT CORRESPONDING SIDEWALK LOCATIONS ON OPPOSITE SIDE OF STREETS WHEN RAMPS ARE CONSTRUCTED ON ONE SIDE OF STREET, SEE FIG. 3-01 O. @ LANDING SHALL BE MINIMUM 4 X 4'. @ CURB RAMP 1A MUST BE INSTALLED UNLESS OTHERWISE APPROVED. 7. SEE FIGURE J-001 FOR CURB AND SIDEWALK JOINT PLACEMENT. HANDICAP RAMP STREET TREE NOTES: 1 . NOTE 1.--'-_,, VERTICAL CURB LINE TREES SHALL GENERALLY BE PLANTED BACK OF THE SIDEWALK, PLANTING STRIPS WILL BE APPROVED ONLY AS PART OF A LANDSCAPING PLAN IN WHICH PLANT MAINTENANCE, COMPATIBILITY WITH UTILITIES, AND TRAFFIC SAFETY ARE DULY CONSIDERED. STREET TREE NOTES: STREET TREE 1. TREES TO BE PLANTED AT APPROX. 40' ON CENTER, WITH ADJUSTMENTS FOR UTILITY FIXTURES AND MAILBOXES. 2. HOMEOWNERS SHALL BE RESPONSIBLE FOR TREE MAINTENANCE FOR TREES WITHIN OR ABUTTING LOTS. 3. STREET TREES SHALL BE: L-r,.&)< DC0\i)c:N:fh1.-1:S ( \Nl;St"E:£.,N LhRCl-i) LOCATE 5' BEHIND THE SIDEWALK (OR CURB, IF NO SIDEWALK) AT INTERSECTION z. STANDARDS 3. IF PLANTING STRIPS ARE APPROVED: A. MIN. DISTANCE FROM CENTER OF ANY TREE TO NEAREST EDGE OF VERTICAL CURB SHALL BE 4 FEET. B. TREES SHALL BE STAKED IN A MANNER NOT TO OBSTRUCT SIDEWALK TRAFFIC. C. IN CASE OF BLOCK-OUTS, MIN. CLEAR SIDEWALK WIDTH SHALL BE 5 FEET IN RESIDENTIAL OR 8 FEET IN BUSINESS DISTRICTS. ON BUS ROUTES, PLANS SHALL BE COORDINATED WITH METRO SERVICE PLANNING. PHONE 684-1 622. ' ,a TRENCH X·SECTION NTS ' Cl .I I 0) i ' " N.D.C.8.U I "' ' r (Q - 6" - l ""-f-ACE OF VERT/CA/. CURB PLAN VIEW NEIGHBORHOOD DELIVERY &: COLLEcnoN BOX UNIT (N.D. C.8. U.,) INS TA/LA 770N NOT TO SCALE" slope- small calch basin or yard drain /, 5700 sq. ft. > 700 sq. ft. PLAN VIEW OF ROOF NTS- - ~ L Type I /, - ;o - 2' X 10' level trenches CB slandard dispersion lrench I w/ nolched grade board englh 10' per 700 sq. II. of roof area, s ee Figure 4.2.2.C of lhe Surtace Water Design Manual INDIV. LOT DOWNSPOUT DISPERSAL TRENCfI - "' I ' -.,-~ 'D " I ,_ ,, )" <o .I -i '" ,. . ,, .. ' .. I . /'-s". I FRONT VIEW . I ' 0 ~ ~ t:3 ""' Cl) ~ ' q ' King County ~ Deportment of Developrnent and Environmental Servlces APPROVAL. FOR SITE CONSTRUCTION Review Engineer ENGRCOMP Date Senior Engineer ENGRCOMP Date ~ DEVELOPMENT ENGINEER APPROVAL Date Comments: ~ ~ i;.; -s: kl tl:i :S q &,.; <o ~ 0 :::iJ 0 -. ....;i 'It< "l <n ~ c::, c,:, "-0 ,... ~ ~ ~ "' c.) (..) L..J ..., 0 O'. a. <n :::, <o 0:, [;JO 0, ~ 0 "? , co I ~ 0:, C") u -"" ~ • (C ~ ;"1 :8 i=: le' 0 s\\l N ~'"l f.'3~ :::zj ..., :,.. "' . -. jho ~ c::, ,c; ~~. ~ "' z <( (..) :J a. a. <( DATE: 3/16/07 SCALE: 1" = 30' DESIGN BY: JJJ DRWN. BY: JJJ APP. BY: FILE No. SHEET 3 OF 1 ------------~ \ EROSION AND SEDIMENTATION CONTROL NOTES 1. Approval of this erosion and sedimentation control (ESC) plan does not constitute an approval of permanent road or drainage design (e.g. size and location of roads, pipes, restrictors, channels, retention facilities, utilities, etc.). 2. The implementation of these ESC plans and the construction, maintenance, replacement, and upgrading of these ESC facilities is the responsibility of the applicant/ESC supervisor until all construction is approved. 3. The boundaries of the clearing limits shown an this plan shall be clearly flagged by a continuous length of survey tape (or fencing, if required) prior to construction. During the construction period, no disturbance beyond the clearing limits shall be permitted. The clearing limits shall be maintained by the applicant/ESC supervisor for the duration of construction. 4. The ESC facilities shown on this plan must be constructed prior to or in conjunction with all clearing and grading so as to ensure that the transport of sediment to surface waters, drainage systems, and adjacent properties is minimized. 5. The ESC facilities shown an this plan are the minimum requirements for anticipated site conditions. During the construction period, these ESC facilities shall be upgraded as needed for unexpected storm events and modified to account for changing site conditions (e.g. additional sump pumps, relocation of ditches and silt fences, etc.). 6. The ESC facilities shall be inspected daily by the applicant/ESC supervisor and maintained to ensure continued proper functioning. Written records shall be kept of weekly reviews of the ESC facilities during the wet season (Oct. 1 to April 30) and of monthly reviews during the dry season (May 1 to Sept. 30). 7. Any areas of exposed soils, including roadway embankments, that will not be disturbed for two days durin9 the season or seven days during the dry season shall be immediately stabilized with the approved ESC methods (e.g., seeding, mulching, plastic covering, etc.). wet 8. Any area needing ESC measures, not requiring immediate attention, shall be addressed within fifteen (15) days. 9. The ESC facilities on inactive sites shall be inspected and maintained a minimum of once a month or within 48 hours following a storm event. 10. At no time shall more than one (1) foot of sediment be allowed to accumulate within a catch basin. All catch basins and conveyance lines shall be cleaned prior to paving. The cleaning operation shall not flush sediment-laden water into the downstream system. 11. Stabilized construction entrances and roads shall be installed at the beginning of construction and maintained for the duration of the project. Additional measures, such as wash pads, may be required to ensure that all paved areas are kept clean for the duration of the project. 12. Any permanent fiow control facility used as a temporary settling basin shall be modified with the necessary erosion control measures and shall provide adequate storage capacity. If the facility is to function ultimately as an infiltration system, the temporary facility must be graded so that the bottom and sides are at least three feet above the final grade of the permanent facility. 13. Where straw mulch for temporary erosion control is required, it shall be applied at a minimum thickness of 2 to 3 inches. 14. Prior to the beginning of the wet season (Oct. 1), all disturbed areas shall be reviewed to identify which ones can be seeded in preparation for the winter rains. Disturbed areas shall be seeded within one week of the beginning of the wet season. A sketch map of those areas to be seeded and those areas to remain uncovered shall be submitted to the ODES inspector. The DDES inspector can require seeding of additional areas in order to protect surfuce waters, adjacent properties, or drainage facilities. CATCH BAS!N il'ISERT ,'vlAINTENAi\:CE SJAJ.NDAF<DS FABRIC 1. ANY ACCUMUI_ATED SEDIMENT ON OR AROUND THE FILTER PROTECTION SHALL BE REMOVED llvllvlEDIA TEL Y SEDIMEi\lT SHAi_L NOT BE REMOVED WITH WATER, AND ALL SC:DIMENT OF AS FILL ON SITE OR HAULED OFF SITE. fi:UST BE DISPOSED 2. ANY SEDIMENT l:N THE CATCH BASIN INSERT SHALL BE REMOVED WHEN !H~ SEDIMENT HAS FILLED ONE-THIF<O OF THE /1,V/,ILABLE STORAGE. I Ht. FILTER MEDIA FOR THE INSERT SHALL BE CL.EAi\lED OR REPLACED A.T LEAST lvlONTHL Y 3. REGULAR MAINTENANCE IS CRITICAL FOR BOTH FORMS OF CATCH BASINS PROTECTION UNLIKE MANY FORrvlS OF PROTECTION TH,'\ T GRADUALLY, CATCH BASIN PROTECTION WILL FAIL SUDDENLY AND COMPLETELY IF 1\JOT MAINTAINED PROPERLY. CATCH NOTE: ONLY TO BE USED WHERE PONDING OF WATER ABOVE THE CATCH BASIN WILL NOT C;\USE TF,AFFIC PROBLEMS AND WHERE OVERFLOW WILL NOR F,ESUL T IN EROSION OF SLOPES. ' GRATE~ BASIN BASIN INLET FILTER N.T.S. F Al L. A PORTION OF THE SW 1/4 OF SECTION 29, TWP. 23 N., RGE. 4 E., W.M. STREET TREE -WESTERN LARCH (LARIX OCCIDENTALIS) PLANTEC,--,,,'- 5' FROM R.O. W. LINE ( 4 TREES) '-- TEMP. CB INLET PROTECTION FILTER 'SOCKS'. ON EX[Sllfl(j CATCH BASINS. (SEE DET.l REMOVE LEGEND CLE:ARING LIMITS TE:MP CB FIL TE:R PROPOSE:]) CONTOUR E:XIST TR££ EXIST. TREE TD BE REMOVED SSMH RJM=376,5 ~o~> (Jl 10" -ff,. PINES };.)( 8" ~Plum REMOVE EX. 12' CCP INV=381.5 BLOCK 4 AkER'S FARMS ND. 5 27 VOL 40, PAGE LDT 12 13001' 300,01' CCALC) 1 .... ) ·,. ~·,.J \') GRAPHIC SCALE I I CONSTRUC1'ION SEQUENC'E' ' 1. Arrange and attend a preconstruction meeting with King County ODES Inspections Unit. Call (206) 296-6642. 2. Flag clearing limits and easements. Flag property lines. 3. Post sign with name and phone number of ESC supervisor. 4. Flag all trees that to be saved. 5. Grade and install quarry spall construction entrance. 6. Install silt fencing as shown on the plans. 7. Maintain erosion control measures in accordance with King County standards and manufacturer's recommendations. 8. Relocate surface water controls or erosion control measures, or install new measures so that as site conditions change the erosion and sediment control is always in accordance with the King County Erosion and Sediment Control Standards. 9. Cover all areas that will be unworked for more than seven days during the dry season or two days during the wet season with straw, wood fiber mulch, compost, plastic sheeting or equivalent. 10. Stabilize all areas within seven days of reaching final grade. 11. Seed or sod any areas to remain unworked for more than 30 days. 12. Upon completion of the project, stabilize all disturbed areas and remove BMPs upon approval of the Inspector. L_ l] T 13 co ()J i--- _J I I EX HOUSE I I L __ _ STREET _Jl,EE -WESTERN LARCH (LARIX OCCIDENTALIS) PLANTED 5' INSIDE OF R.O.W. LINE (4 TREES) King County Department of Development and Environmental Services APPROVAL FOR SITE CONSTRUCTION . Review Engineer ENGRCOMP Date Senior Engineer ENGRCOMP Date 20 0 10 20 40 60 ~m::••iJ"'ffl'liff:W~~ (IN!'EET) inch = 20 ft. DEVELOPMENT Comments: ~- E1'IGINEER APPROVAL Date REVISIONS: REV. PER CTY. OMMEN TS 10-1-0- 1------------· "' (.) w -, 0 Cc'. 0. (j z er w w z (j z w E,.., ~ E,-; ~ ~ 0 t;;i ~~ ti) :S ~ (0 0 0 ...... ~ "' 0-., 0 ~ ('.. .... ~ ~ l.) ~ c3 ~ c:-< ~ a u . ~ t/i ~ 2:; a ~ C) ~ ~ 8<l N DATE: 3/16/07 SCALE: 1" = 30' DESIGN BY: __ J,b!__ DRWN. BY: JJJ APP. BY: FILE No. SHEET -~Lj,.___ L! OF • CONDITIONS C)F APPROVAL ® King County Department of Dcvel1)pmenl and Erwironmental /,lorvices 90D Oakesdale Avenue SW Reriton, WA 9B055-t219 CO;'\DITIO~'S OF APPHOV.-\L File No. File Name: LOJS0IJl6 Chau Short Plat ,\fay 2, 2003 Jan@ry 30, 2004 Application Date: Rcvision Date: This shoi1 subdiYi5ion is granted preliminary approval subjcct to the following Conditions of Approval. Tbesc conditions arc based on a field visit and current information the applicant has pro.-ided about the slio11 subdivision propaty. Occasionally, in safo,fying tl1c Conditions of Appronil, a nwre definitlve laud use limitation of the propcny may be rc\'calcd. New information (sucli as finnl Health approval or si:nsi(i\·e areas rcview) may require additioml conditions a11d may reduce the uumbcr oflo(S. Finc1l npprU\·al Will be granwd after compliance \\·ith ihe Conditions of Appro\"al. Key codes and guidelines Jrn1·e be<c'n noted to prol'ide guiJam:e in pn:paring the requlrt'd plans and oihcr docutllents. Colll)iliance with some of the following conditions \\"ill require that engineering pl 11 ns be prepard l>y a professional ci1 ii engineer licensed 1n the State of Wasliington. I. Title 19,\ A. Tilt: short st1bdi1·i~ion shall comply wlth al! provisions ofTit!e 19.A. B. T!Je final rc\·iew process must be completed prior to recording of the short subdivision. Th<c Department of Dt:Hlopment and Environmental Serl'ices (DLJES) strongly recomnicn<ls the final Shot1 Plat be submitted ;it least one vca1· prior to the e:\pirntiuu date of the prok_,j. The Fin:i.1 :short Plat subm11tal package includes: J. A sun e,yed map puge (four sets) including lot area closure calct1lations; 2. Final health approval from the King County Health Department (difkt·ent [i·om preliminary health approval); 3. A cu1Te11t short plat certificate and supporting doct1rncnts (easemc11ts, etc.); 4. Paym.:nt of the Final Short Plat submittal fee; 5. A copy ofll1is letter (preliminary approval lelt<.'r). A licensed land surl'eyor ~ball be hired to prepare the fowl sho1i ~ubJil'ision documenu. These documents shall comply witl1 all oftlic following co11ditions for final appt"O\'al: C. All persons having an ownership interest in the subject property are required to sign the final short subdi1·ision. D. ](modifications to the approved preliminary site plan (Atwchment I) are needed to accomplish engineering design or final short plat, then a revised preliminary site plan shall be submitted to ODES for review .!nd approYal. Tile! revised site plans shall be submitkd with the engin..;,ering plans or the final short plat SL1hmittal. 2. Surface \\later :\1anagement (KCC 9) 3. 1998 King County Surface Water Design .'\lanunl {SWD.'\l) A. TJ11s short SL1bdivision proposal is sobject to Fu!! Drain::ige Review per section 1.1.2.3. final short SL1bdi\·isio11 approl"a] shall require full complianc:c \,-ith dr:iinage provisions and stom1 drainage requirtments of this section. Compliance may result In reducing the nmnber and/or lorntion of lots shown 011 lhe approl'ed preliminary short subdiYision. The conditions outlined below ar<: site-specific drainage conditions: (1) Core Rt'4uiremc11t #I· Discl1arge at the Natural Loc~~tion (2) Core Requirement #2 -Off-Site An:ilysis (3) Cor!.' Hc4uircment #3 -Flow Control (-1) Core Rcquircmcut #4 -Co1l\·eya11c..: Systern (5) Core Rcqoimocul #5 · Ero,irn, & Scdimrnt,Hiou Crnnrnl (6) Core Hcquircmrnt #6 -:\1:ti11ten;'1h·e :md Operatiun (7) Core H.equircrnc111 #7 -Financial G•.1arantecs & Liability (8) Core Require11H'11t #8 -Water Qo:di!y (S l) Special Requirement# I -Other ,\Jopted Requif<.'llH.'nts B. A.r_irofe~sionn] ci\'il ~ngine<:!r licensed in the Stntc of Washington shall prepare a l <.:dm1cal fnforrmmon Report and/or engineering plans per Chapter 2, oftl1e 1993 King County Surface Water Design 1\fanual. Htnlth (KCC 13) This project is exempt from fur1her King County Heath Department review. [fowever, if impron:ment~ are requin:d from 1l1c Sc wet· and/m· thc Water Di:,trict, then verification shall be required from said District(s) 1hat the irnprnvemc111s h<i\'e been bonded and/or installed, prior to final recording of the short plat. 4. Road Standards (KCC 14) 1993 King County Road Standards, Ordina1H'C 11187 Final short subdivision approval ~hull require full compliance with the pro\·isions set forth in the King County Road Standards including engine,,:ring plans for all road improvements. The engineering plans sliall be prepared by a professional cil'il engineer licensed in the State of Washington. ODES strongly recommends tbc Engine<:ring !'Jans be submitted at least two vears prior to the expiration date of the project. A. That portion of the Nortli half of SE l 72"J Street adjoining 1hc subject property shall be impro\"ed lo an urban Sub-access standard per KCRS Stction 1.03. B. That po11ion of the East half of 106th A\'enue SE adjoinillg tile subject prope11y shall be improved to an urban Sub-access stwdard per KCRS Section 1.03. C. Pro\·idc 35' pal'ed radii cit the inler:,cction of 106 1h AYcnue SE c1nd SE 172 Street per KCRS Section 2.10. Dedicate a 25-foot prop<.'ny line radius at the intersection of 106 1h Avenue SE and SE 172"J Str<:c( pi:r KCRS Se('.tion 2.10. D. Existing roadside obstack(s) shall be n.:locntcd to prn\·ide a minimum cleararic<: of 10 fret from the edge of the tra\'e] Jane to the obstacle(s) per KCRS Section 5.1 J. E. Prin1k access to l(,1.s 2 and 3 shall be shown as ajoi11t-Lise drin'\\·ay tract per KCRS Section 3.01. The tract sliall be an undi\'ided ownership lo the lots it setYCS, a:1d tlie lot owners shall be responsible fur its m:1intena11ce. Tl1r: tract shall be 20-feet wide with a 18-foot-\'."idc paved surfoci:. The tract shall be a minimum of20 fo..:1 i11 !cnglh. UTILITY CONFLICT NOTE: CAUTION: 8. lHE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING lHE LOCATION, DIMENSION AND DEPTH r G. H. Tl1e /Ullowinu notes sh·ill b ·I . I 1. =-· es 1011 ,1 on t 1e ma! recorded sl10rt subdivision: I) 2) \\:~rni_ng: King C?tmty hJs no responsibility to build, improw, m.c1 1ii_ta_m or oth~'r11·1se ~tnxe the privnk roads contained within or PIO\ idmg si:ni,;,~ lo the prop,Tty described in this sliort subdii·islon All printe easc111er1!s an&'or t1·acb to b<: maintained, repaired and/ rebuilt by tlie mine . f 1 . . 1. 1 _ , or . . rs o t le p,111.:e ~ 111\"tng legal access tliet·efrom ·, I tlieir l1··1rs · · , nt . . ~ , ,1s~1.g 11s or succe:;surs, Ullless and until sucli roads an; 1mp1 01·cJ co Km" Co 1 , 1.. ,, , 1 . , ,, LIil } s nnu<1rus a11c arc dedicated anrJ accepted by K111g Cou111y for 1nai11tenarn.:c Al I util i tk~ 11 iti1i11 pt opuscd rights-,H~w«y shall be Incl udcd within a fra11ci1i~, ~pproi_ed by !ht: Krng County Council prior 10 final sho;1 st1bciil'ision c recordmg. • All restrictions, easements, tracts, and their purpose shall be sho\vn on the final recorded short ~ubdi 1·isil!11. 5. Building and Cumtruction St:1ndards (Title Hi) Grnding. Tlic applicant shall comply \\"ith nil applicable provisiom of KCC J 6.82. G. Fire Code (KCC 17) Sl'ction 902 of the 1997 Edition oflluiform Fire Cotlc The applicant shall obtain the apprO\·a! of the King County Fire Protection Engineer for the <1dequacy of the fire hydr:mt, water main, and fire flow standards of KCC 17.08 prior to recoding of the lots. 7. Zoning Code (KCC 2L\) C. D. A. Dernity and Dimensions (KCC 21 ;\. l 2) All lots slrnl! mi:ct the c.lc11sity :rnd dimensions requirements of the R-8-SO zone classification or shall be as shOll"ll on the face of the nppro\'ed prelimi- nary sho11 subdi\·ision, \1hiche1·er is brgcr. 1'.1iuor revisions to tbe shon subdivision, which do not result in sobsta11tial changes amilor do not create additional lots m~1y be appro1·ed at till.' disrn::tion ofLUSD. fl Street Trees (KCC 2JA.l6) Stre\.'l trees shall be pro\'1ded along that ponion of the right-of-way for 1 06'1, A venur..: Somhea~t and S0c1theci~t 172"6 Street abutting the subject prnpe1·ty, 1mrn1:mt w the 11~0\·isio11s of KCC 21 A.! 6.050(E) :md KCC 21 A .. 16. l 90. u11lt:~s exist1J1g trees :;re shown to be equivalent to the reqw:-emem of Code. Si::e note below. The required street trees shall be designed as to location :111d spacing on the final plan submittal. The street t1·ees must be installed and imJ1ectt:d, or a pnfornrnnce bond posted, prior to ;·ecording oft_he pli\l. If :1 pcrfornumc<.: bond i~ po~t<.:d, (he street trees must be mstalled and 111sp•.:cti.:d \I 11hin unc year of recording of the plat. At the time of inspection, 1fthc trees a1~ found to be installed p\.:'r the approved plan, a mnill(enance bond must be submitted, or the performance bond replaced with a m.aimenauce bo1id, and h"ld for one year. ,\ftcr one year, the maintenance b.ond may be n:kased afti..:r ODES J1as eomple(l:d a ~econd inspection and determined iliat tho: trees lrnn~ been kept healthy and thriving. c/OTE I. KCC 2 IA.16.050 Landscaping -street frontages. The average widtl1 ofpcrimet...:r landscaping along stn:cl frolllagcs shall be proYided as follows: For single-family subc.lil"islons: a. ~recs sh.ill be planted at the rate of one tree for e\"Cl)' 40 feet of frontage along a neighborhood collector street or arterial street. b. The tn~es shall be: I. Located within tl1c street riglit-of-way if permitted by the custodi:.1! state or local cJgency; 2. No more than 20 feet from the stw~t right-of-way line when located wi1hi11 a lot; 3. l\faintained by the adjacent landowner uuless part of a County mnmtenance prugrnm; and 4. A ~pccies :-tpprovcd by the County iflocated within the street rigLt-ol~way au<l compatible with ol'er!icad otility llnes. c. Tile trees rnay be spread nt irregular interl'als in order to ~ccomm?c!ate sight distance requirements for dril'eways and mtersecuons. 2. KCC 21 A-16.190 fillancial guarantees. Financial etiarantees shall be reqrnred consistent ·,\·itli 1hc provisions of Title 27 A. ~ Sig1~if1cant Tree Rl'tcntiun. KCC 21 A.3S.230 ll'hid1 applies to t!it: site, a ,kta1Jcl: tree ret<c'1.1twr1 plan shall_ be submitted \\'ith the ..:ngineerlng plans for the ~:tbJect p_lat. I he tre_e wenllOn plan (um.I cngine..:ring plans) shall be cons1stent_wJth th<.: requirements of KCC 2 J A.38.230, as \1·ell as the conceptual tree r_ete11t10n plan .'·1·h1ch 1s j.lC11 t of the hearing record for 1his project. No dearmg of1l1e subJect.prop_eny is permitted until the final tree rctemion plan is approved by LUSD. flagg111g and telllporary fencing of trees to be retained sh"dl be pro\·ided, consistent \\"llh KCC 2 IA.38.230I34. The placement of 1mpcrv1o~s smfat·t:.:,. fill m:Hi:rial, excavation work, ur the storage of construcl1m1 r;1atrnal~ 1s prol11bitcd l':ithin the fenced areas rirotmd preserl"e<l trees, excep( for grndmg \\"Ork permi(tcJ pursuant to KCC 2 IA.38.230134d(2). A n~te shall be pl:iced 01i the fiJlit! plat indicating that the trees shown to be retam..:d on the tn.'e relenlion plall 5hnll be maintained by the foturc owners of tl1c pr?pcsed lots. consistem with KCC 2 lA.38.230!36. (Note that the tree rete.ntion plan shall be mcludcd tis pan of the final cngineeri11g plans for the su.bJc.ct plat.) Jf:)lere are no si1mi/ica11t trees as definec,I bv the Special Overlav D1stnct on 1he site then. thJs requirement does not apply. The <:xisti1:g house ~hall_ ~e remo1"CL! or demoli~lied prior w the final approval and reconlmg. A demol1uon permit shall be obtained prior to demolition. l{tJ;1d .\fitigation l'aym<:.'11( Sysll'm LEGAL DESCRIPTION OF ALL EXISTING UTILITIES WHETHER SHOWN ON lHESE PLANS OR NOT BY POlHOLING THE UTILITIES AND SURVEYING lHE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONS1RUCTION. LDT 13, BLOCK 4, AKER'S FARMS NO. 5, ACCORDING TO THE PLAT THEREOF, RECORDED IN VOLUME 40 OF PLATS, PAGE 27, IN KING COUNTY, \./ASH!NGTON, EXCEPT THE VEST 170 FT. AS MEASURED ALONG THE NORTH LINE THEREOF; lHIS SHALL INCLUDE CALLING UTILITY LOCATE @ 1-800-424-5555 AND lHEN POlHOLING ALL OF lHE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSING TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE NOT GUARANTEED AND ARE SUBJECT TO VARIATION. AND EXCEPT THE NORTH 60 FT. OF THE REMAINDER. 9. I 0. The applicant shall comply with Road Mitigation J!;Lyment System (MPS), by paying the required lv!PS fee as dctcrrnincd by King Coon()' Department ofTrnnsporiation, plus an adminimative fee. The applicant has an option to either: A. Pay the .\1PS fee at final short ~ubdivision ]'Gcordiug and tl1c MPS administrative ft:c at final short subdi\·isiun application, or D. Pay the MPS fee at building permit issuance and the N-11'S administrative fee at the time of building permit application. If option A is chosen, then the following note shall be shown on tl1e final slrnrt plat: :\IPS FEE i\'OTICE: All fees required by King County code J,1.75, Mitigation l'nyment System (MPS) hal'e been paid. If option B is chosen, then the following nole shall be shown on the final short plat: ;\ll'S FEE NOTICE: Tliis short plat is subject to King County Code Nq. 14.75, King County Road Mitig,11ior1 Payment Syskm (;\!PS). The JV!PS kcs plus tlii.: MPS administrnli\T ft·e shall be paid at the time of building perrnit ,1pplic11ion at the r:1te in cfft:c! at that time. Stall' Environmental Polk~: .\ct (SEP,\) Thi~ short subdi\'ision \\·,1~ exempt from the provision of the Stare Environrncnt,d Policy Act (SEPA). Other Considerntions Prcliminar)' approYal of this application does not li1llil tlic applicant's responsibility to obtaln any reqt1iri.:d permit or lteemc from the State or other regulatory body .. This may include obtaining a forest practice permit from the Waslilngton Stale Depa11ment of Natural Resources for tree rerno\·aJ. VERTICAL DATUM, NAD 83, PER \./SDOT GEOGRAPHICAL INFORMATION REPORT BENCHMARK, CONCRETE MONUMENT IN CASE\.// A BRASS PLUG@ THE INTERSECTION OF SR 515 B. SE 180th ST. ELEVATION = 402.09' PER \./SDOT GEOGRAPHICAL SERVICES SURVEY MARK REPORT, MONUMENT I.D. lt2606 AND DESIGNATION #IS 1765. Vici n it y M a p ~i ; S\.I 23RD ST . I ,._ 1:· w ' ....J -·,-··----:.J >' <( < I > I ST I ------·-- " s· ;ti I ':: SW ._?iTJI ST Soils Mop t N Notice Required Contractors shall notify operators who maintain underground utility lines in the area of proposed excavation or blasting at least two business days, but not more than ten working days prior to commencement of excavation or demolition in accordance with RCW Title 19. Names and telephone numbers of the operators of underground utility lines in this project appear below. These numbers shall also be used to serve in an emergency conditions as required. Phone SOOS CREEK WATER & SEWER DIST. (253) 630-9900 Sanitary Sewer SOOS CREEK WATER & SEWER DIST. (253) 630-9900 Water District PUGET SOUND ENERGY ( 425) 454-6363 Gas Company PUGET SOUND ENERGY (253) 395-6915 Power Company Coll Before You Dig DIAL-A-DIG 1-800-424-5555 Notes 1. The Developer is required to notify the Land Use Services Division, Land Use Inspection Section (206) 296-6642, three days prior to the beginning of construction for o preconstruction conference and 5pecifically request inspection before beginning: A. lnstu!ling siltation and erosion control measures B. Clearing and grubbing C. Earthwork D. Installation of any underground uttlity E. Before placing subbase, base or paving surfaces F. Installation of any forms or placing any concrete 2. A permit must be obtained from the office of the Resident Engineer, Washington State Department of Transportation, before any construction is started on any existing state route. 3. A Hydraulic Project Approval (HPA) Permit must be obtained from the Washington State Department of Fisheries prior to any work when required. f----------------------------,·--------~--------1 Bon ding Information Restoration Bond Amount $ Performance Bond Amount $ -------- Site Plan Approval Approval of these plans is for construction of road and drainage improvements, site drainage & grading and temporary erosion control in unincorporated King County only. These plans do not authorize any other utility approval or improvements proposed in any State right of way. Site plan approval is void if the commercial building permit has not been obtained or renewed within two years of approval. Subdivision plan approval is void if the final plat is not recorded prior to the preliminary plat approval expiration. ASSESSORS NO.: 008700-0280 PRO RATA SHARE ASSESSMENT ANALYSIS (County Use Only) Section Township Range Tax Parcel Number 291 12131 10141 I o 10 I 8 17 I o 10 I o 12 I 8 Io I Site Location Is within the _ GR_EE~J3IVER drainage shed(s) Pro Rota Share Assessment(s) are: D Required D Not Required from the site due to development for increased storm water runoff. Peak Runoff Assessment Rate($ Peak Volume Assessment Rate($ ) per c.f.s. !ncreases.(10 year, 2 hour storm) ) per Ac. Ft. lncreases.(2 year, 2 hour storm) AGREEMENTS, PLAN REFERENCES, PERMITS ETC. (To be completed by Consultant) Preliminary Plat Approval/Permit Issued Date: MARCH 12, 2004 Expiration Date: MARCH 12, 2009 Other Related Permit Numbers Received: Right-of-Way Use Permit Grading Building/Structural Other _____________ _ Board feet of tree removal on site: Cubic yards of material hauled on/off the site: NONE Is this a erosion sensitive area site? (Yes/No): __ N_D __ _ Nate: If "yes", a Highly Sensitive Site Erosion Control Supervisor is required. See ESC plan and TIR for details. Date Emergency 911 Police-Fire-Rescue RECOMMENDED FOR APPROVAL (To be completed by King County) Engineer Plan Reviewer Engineer Supervisor Traffic & Planning Engineer Sensitive Areas Structural Review Engineer Other APPROVED FOR CONSTRUCTION DEPARTMENT OF DEVELOPMENT & ENVIRONMENTAL SERVICES Date .9- .c ~ ~ fil Q) (() ~ C C (I) " " ::, oot= !31 D D 18 King County, Washington James H. Sanders, P.E. Development Engineer PROJECT CONTACT INFORMATION ___ H_A_M_I_N_H_C_H_A_U __ ___,( 425) 643-3993 Name 4101 150th AVE. SE Phone BELLEVUE, WA. 98006 Address and Zip Code D A Partnership gi An Individual ___ H_A_M_IN_H_C_H_A_U __ _____,_( 425) 643-3993 Name 4101 150th AVE. SE Phone BELLEVUE, WA. 98006 Address and Zip Code D A Corporation D A Partnership 13 An Individual _J_A_E_G_ER_E_N_G_IN_E_E_R_I_N_G _ ____,_(253) 850-0934 Name Phone 9419 S. 204 PL. KENT 98031 Address and Zip Code LD 1 s "2.o"Z, ,z,. \.._ CJ 0 (/) z > \.._ -Q) a: 0... :::J w U) "'--w \.._ Q) z Q) C -CJ) CJ C w z "'--+-' w u Q) +-' .c a: u w \.._ <( CJ C CJ) w (/) Q) <i: 0 "") Qj C,) (iS -. ."'t 0.. C') .J:l C ...., co 'tj< o:i c::::, C\i • ..::: ~ ...., :::l • 0...., Cl) 1:1 o:i ~ "'t 'tj< o:i '<f- t<] 0, 0 I 0 U") co w a: a{ w (.'.) w <( -, -; vr w :::;; <( -, Q) C 0 .c (L \.._ 0 +-' 0 C "D L 0 0 u +-' u Q) ·-. 0 L (L ~ [E~[E~\W[E~ APR O 9 2007 KC. D.D.E.S. <:c '"'I C C Cl) r,,-:, (fl c::::, O::'. ,....:i w (I) .. 2 L L 0 Q) Q) z :=) _o _o z E E ..µ C w :::J :::J Q) __J z z E LL >-, ..µ 0... ..µ u 0 U) > Q) Q) w ·-. 0 +-' 0 > u L Q) 0 <( (L 0 License/Seal Sheet 1 of 3 ... ----! ROFILE -~ EXIST r·-------,------------·-···----------A PORTION OF THE SW 1/4 OF SECTION 29, TWP. 23 N., RGE. 4 E., W.M. 390 .c NORTH PVMT. EOG o -t----~·i,Sl• -------390 (!) 0 -PROFILE @ PROPO ED ;::' d CURB FLOW LINE ~ _... ------ ~T 5 st----lE:-386:-7--1-------,r-=3~8~__, 0 ----3851~~--___:-------l~-+--+-------=---+---=--.--j=--------=i--= 375 2+66.91, 26.2' LT k,--=---1 ------;----------+---->-'C=B~1'--'-'T~YP~E-1,_,_--+---------+-"3~8. Q_ RIM: 388.0 IE: 385.0 --t--t------------c ---+-------------·---+------·----------· --------- 1 +52.39, 21.2' LT CB #2 (TYPE 1) RIM: 380.91 IE: 377.9 ----------+-----+---------+------------>--- 375 370 "' t-- EX Is s M~ j RIM=383.0 1e_, EX. 12' CCP INV=381.5 BLOCK 4 AKER'S FARMS ND. 5 VOL 401 PAGE 27 LDT 12 WEDGE FLOW LINE TO BE DIRECTED TO CATCH BASIN AS SHOWN ON PLAN 20' w --+-----------1...,;a:: TRACT 18' f- 0 ...J 1' -+---------·- 1 1/2" MIN. COMPACTED DEPTH CRUSHED SURFACING TOP COURSE 2 1/2" MIN. COMPACTED DEPTH CRUSHED SURFACING BASE COURSE , ~ L II s 15 ~ ·•· 300,01' CCALC) 300' CPLAT) ADDITIONAL TREATMENT MAY BE REQUIRED DEPENDING ON SOIL CONDITIONS. SEE SEC. 4.02 1+00 390 l:> _c r----...J 0 0 0 385 + 0 . 380 - 375 370 10+00 SCALE: 1" 1 " -- ' 20' HORZ. 5' VERT. --- m· 0:: 3 I 0 Q. .... N 0, ·-+. 0 - --- SE 2+00 172nd ST. (URBAN SUB ACCESS) ' r__FROFILE @ EXIST EAST PVMT. EDGE I PROFILE.@ PROPOSED CURB FLOW LINE ' I 4.fj: ---~ > ---- ' SCALE: 1" >-' (/) :,: x '-w 0:: VARIES 1" - 5' SIDEWALK 0.5' 1&! 46.1, 14.55' RT LOV PT OF CURB CB #3 (TYPE --1) RIM 377.1 IE: 375.5 (EX. 12") - IE: 375.4 (NEW 12") SE OVER EXIST. 12" I!) ... "' 0, " 0, " " t') t') 20' HORZ. 5' VERT. 11+00 106th AVE. SE (URBAN SUB ACCESS) 30' 12' VARIES -------------·----...,._ _ ___,_, ()._ 0 w SAW CUT VARIES ±7.5' (106th) I' INSIDE EX PVMT. (106th) 4' (172nd) ---+-·t----c-;4, INSIDE E . PVMT. (17 nd) ui ~ 0 390 c.i 0 z w (!) 0, 385 ... T -- -- 380 375 370 t') ... -ro t') 3+00 STREET TREE -WESTERN LARCH (LARIX OCCIDENTALIS) PLANTE 5' FROM R.O. W. LINE ( 4 TREES) REMOVE EX 10" CONC. RET. WALL w~- 3:; -~ 111 -··-l rd ~ ll;t;}:pp '~I l;)i 11 [ ' 1 ~ 3 11 . ----· -.-- I t--2 f-t II Z ASPHALT ~ iWJ D/IJ APRON $1 ·. II ,:r: ' 0: ~ SIDEWALK TRANSITION RAMP-~1 11+49.6 PROP LINE~---~ END CURB, GUTTER & SIDEWALK RELOCATE EXIST. MAl~BOX & ADD 2 BOXES I 10+46.1, 14.55' RT LOW PT OF CURB -,~ CB #3 (TYPE 1) ~ RIM: 377.1 IE: 375.5 (EX. 12") IE: 375.4 (NEW 12") SET OVER EXIST. 12" IE1 375,2 (12' D NE\./ IE, 375,2 (12' N) NE\./ ADD SOLID, LOCKING LID @------ 12' RCP // INV=369.7 5" 1/4" EDGED 130.01' I EXTEND NEW ASPHALT TO --EXIST, DRIVEWAY ASPHALT I I CONC, I EX HOUSE I I ' -,- I I 1 +52. 39, 21.2' LT CB #2 (TYPE 1) RIM: 380.91 IE: 377.9 20% EXIST/ G PAVEMENT 172nd) 2% ~,,_+ '·, • , __ .... ~ ·_": -~::.i >-:- 7" I 1''R -- \ f GROOVE 2.0% SSMH RIM=376.5 SE ·" / ~ ']..· 4" THICK CONC. WALK VERTICAL CONC. CURB & GUTIER CROSS SECTION 172nd ST. & 106th AVE S (URBAN SUB ACCESS) N. T.S. EXISTING PAVEMENT 106th) 2" CLASS "B" ASPHALT CONCRETE 1.5" COMPACTED DEPTH CRUSHED SURFACING TOP COURSE 5" COMPACTED DEPTH CRUSHED SURFACING BASE COUSE ADDITIONAL GRAVEL MAY BE REQUIRED DEPENDING ON SOIL CONDITIONS 16" i "• I .. · • . " 1 . . ;, ' . ' 5.0% I • : ..-1.. ..:.:. , ' ' ', ' • I I ",4.,,i . '• ' " ,. • . ii, . .. .. 78" OR 24 >T *NOT[. TOP OF CURB @ DRIV[WA YS CEMENT CONCRETE VER T!CAL CURB AND GUTTER NOT TO SCALE NOTE: 1. TRACT "A' IS A JOINT USE DRIVEWAY TRACT TO BE JOINTLY OWNED AND MAINTAINED BY LOTS #2 AND #3 . 2. EXISTING WATER MAIN SHALL BE LOCATED BY POTHOLING PRIOR TO INSTALLATION OF DRAINAGE SYSTEM. 20 0 ~ -Ill -- 12' CONC. RET. \./ALL \/ITH \.JOOD FENCE (VALL ON PROP. LN.) GRAPHIC SCALE 10 20 40 j I • ( IN FEET ) 1 inch = 20 ft. . co (U g- TRACT ,, A" JOINT USE DRIVEWAY TRACT LDT 13 r---- 1 I I EX HOUSE I I L __ _ N.T.S. STREET TREE -WESTERN LARCH (LARIX OCCIDENTALIS) PLANTED 5' INSIDE OF R.O,W, LINE (4 TREES) EX. POLE TO REMAIN EX. 12' RCP INV=390.3 King County Department of Development and Environmental Services APPROVAL FOR SITE CONSTRUCTION Review Engineer ENGRCOMP Date Senior Engineer ENGRCOMP Date 80 :, DEVELOPMENT ENGINEER APPROVAL Date Comments: REVISIONS: 0 z -a: (l) 'I' w Q (~ in I!") w .... 0:, I!") 0... ..... 0 .... t";) I <::, z COi ~ o::i I!") <::, -..., ~ co I!") 0 '<ti c:o C -;;- z ~ • I!") -;;- :S~~! ill ~ .. 0 . a: o-::;~~ r:Jj (l) ~ ill ~ :.:: i:l ?1 ..... 0 <1! 0 ~ ii: ~ 01 w ffi < \g "") 'a '-' Cl(_ -- h ~ h ~ 3 ~ Q. 0 ~ ~ ~ ·O:: ,Cl ~ . ..., ~ h <o 0 0 .... ~ •.;, ~ ti') <::, ~ ~ l'-,.., ~ ~ ~ ,:: u (.) w , 0 "' CL in ~ 'O 0:, ~ 0 0:, ~ C in ~-~~ ·<t: ·:-,: <o ~ ~ 1;1::--., . . IO 0 i:.:i'(\) ::g ~~~ ..... la:l c:i ~ 0 >--1 2:; .... ~ -.jl ll:! 0:: Q. ,:: z < (.) :J CL CL < DATE: 3/16/07 SCALE: 1" = 30' DESIGN BY: JJJ DRWN. BY: JJJ APP. BY: FILE No. SHEET 2 OF 3 GENERAL NOTES 1. All construction shall be in accordance with the King County Code (KCC), Road Standards (KCRS), and the King County Council's conditions of preliminary subdivision approval. It shall be the sole responsibility of the applicant and the professional civil engineer to correct any error, omission, or variation from the above requirements found in these plans. All corrections shall be at no additional cost or liability to King County. 2. The design elements within these plans have been reviewed according to the King County Department of Development and Environmental Services (DOES) Engineering Review checklist. Some elements may have been overlooked or missed by the DOES plan reviewer. Any variance from adopted standards is not allowed unless specifically approved by King County prior to construction. 3. Approvul of this road, grading, and drainage plan does not constitute an approval of any other construction (e.g. domestic water conveyance, sewer conveyance, gas, electrical, etc.) 4. Before any construction or development activity, a pre-construction meeting must be held between the DDES's Development Inspection Unit, the Applicant, and the Applicant's Construction Representative. 5. A copy of these approved plans must be on the job site whenever construction is in progress. 6. Construction noise shall be limited as per King County Code (Section 12.88); normally, this is 7 a.m. to 10 p.m. weekdays and 9 a.m. to 1 O p.m. on weekends. 7. It shall be the applicant's/contractor's responsibility to obtain all construction easements necessary before initiating off-site work within the road rights-of-way. 8. Franchised utilities or other installations that are not shown on these approved plans shall not be constructed unless an approved set of plans that meet all requirements of KCRS Chapter 8 are submitted to the DDES's Development Inspection Unit three days prior to construction. 9. Datum shall be KCAS unless otherwise approved by ODES. 1 o. Groundwater system construction shall be within a right-of-way or appropriate drainage easement, but not underneath the roadway section. All groundwater systems must be constructed in accordance with Section B1 3.02 of the APWA Standard Specifications. 11. All utility trenches shall be back filled and compacted to 95 percent density. 12. All roadway subgrade shall be back filled and compacted to 95 percent density (WSDOT 2-06.3). 13. Open cutting of existing roadways is not allowed unless specifically approved by ODES and noted on these approved plans. Any open cut shall be restored in accordance wrth KCRS 8.03(6)3. 14. The Contractor shall be responsible for providing adequate safeguards, safety devices, protective equipment, flaggers, and any other needed actions to protect the life, health, and safety of the public, and to protect property in connection with the performance of work covered by the contractor. Any work within the traveled right-of-way that may interrupt normal traffic flow shall require at least one flagger for each lane of traffic affected. All sections of the WSDOT standard Specifications 1-07.23 -Traffic Control, shall apply. DRAINAGE NOTES 1. Proof of l1ability insurance shall be submitted to ODES prior to the pre-construction meeting (KCC 9.04.100.0). 2. All pipe and appurtenances shall be laid on a properly prepared foundation in accordance with WSDOT 7-02.3(1). This shall include leveling and cortlpacting thu trench bottom, the top of the foundation material, and any required pipe bedding, to a uniform grade so that the entire pipe is supported by ..i uniformly dense unyielding base. 3. Steel pipe shall be galvanized and have asphalt treatment #1 or better inside and outside (KCRS 7.03) 4. All drainage structures, such as catch basins and manholes, not located within a traveled roadway or sidewalk, shall have solid locking lids. AJI drainage structures associated with a permanent retention/detent1011 facility shall have solid locking lids (KCRS 7.05) 5. All catch bm:iin grates shall conform to KCRS drawing numbers 2-013, 2-018, 2-019, or 2-020, which includes the stamping "OUTFALL TO STREAM, DUMP NO POLLUTANTS" and "Property of King County' (KCRS 7.05). 6. All driveway culverts located within King County right.of-way shall be of sufficient length to provide a minimum 3.1 slope from the edge of the driveway to the bottom of the ditch. Culverts shall have beveled end sections to match the side slope (KCRS 7.03(L), DraVving No.2-001). 7. Rock for ero:;ion protection of roadway ditches, where required, must be of sound quarry rock, placed to a depth of 1 foot, and must meet the following specincations: 4"-8" rock/40%-70% passing; 2"-4" rock/30%-40% passing; and-Z' rock/10%-20% passing. lnst<Jllation shall be ln accordance with KCRS 7.02(8) drawing number 2-024. 8. Drainage outlets (stub-outs) shall be provided for each individual lot, except for those lots approved for infiltration by King County. Stub-outs shall conform to the following: a) Each outlet shall be suitably located at the lowest elevation on the lot, so as to service all future roof downspouts and footing drains, driveways, yard drains, and any other surface or subsurface drains necessary to render the lots suitable for their intended use. Each outlet shall have free-flowing, positive drainage to an approved storm water conveyance system or to an approved outfall location. b) Outlets on each lot shall be located with a five-foot-high, 2'' x 4" stake marked "storm" or "drain". The stub·oul shall extend above surface level, be visible, and be secured to the stake. c) Pipe materit1I shall conform to under drain specifications described in KCRS 7.04 and, if non-metallic, the pipe shall contain wire or other acceptable detection. d) Drainage easements are required for drainage systems designed to convey flows through individual lots. e) The applicant/contractor is responsible for coordinating the locations of all stub-out conveyance lines with respect to the utilities (e.g_ power, gas, telephone, televlsion}. f) All individual stub-outs shall be privately owned and maintained by the lot homeowner. DETECTABLE \/ARNING PATTERN <SEE DET AIU 4' -O" MIN. 6' -O" MIN, /8' EXPANS!ON JDJNT <TYP,) TD, PLAN F-3) A CROSS\/ALK (TYP,) ;-(SEE STD, PLAN H-5c) SJDEw ALK RAMP TYPE 1A PLAN IJOTES CEMENT LANDING 2% :. I ~· , .. CONCRETE 7 1 . SIDE\/ALK RAMP ?' O' c -=: C: 1f~_{•r~~;, T \_ DEPRESSED DETECTABLE \/ARNING CURB & GUTTER PATTERN (SEE DETAIL> (SEE NOTE 3) SECTION (3_) I 6' -O' MIN, LJ::0 ,. TOP OF ~::-.d'" ~. "':l::_-.,/A rRDADIIAY °"'yl:,.""v,· ... I f l ?.,'-i- cEMENT CONCRETE _/ ~\_.,-- SIDE'w'ALK CEMENT CONCRETE (~ ··,. CURB & GUTTER SECTION B ) (SEE NOTE 3) 1. Avolcl plo.clng clro.lno.ge structures, junction boxes or other obstructions In front of re.Mp o.ccess o.reo.s, 2, Detecto.ble wo.rnlng po.tterns sho.ll be texturecl using trunco. teci cloMe po. ttern (see cleto.ll), 3. Curb o.ncl gutter shown, see the Contra.ct Plo.ns for the curb cleslgn speclflecl. See Stcl. Plo.n F -1 for curb cieto.lls. 4. The plo.n views for SIDE\/ALK RAMP TYPES !B, !C 3' 1D a.re proviclecl to cleflne ea.ch re.Mp type, See the RAMP DETAIL on this sheet. See Std. Plo.n F -3 for slciewo.lk joint plo.ceMent o.nci cieto.lls. 5. Ro.Mp slopes sho.ll not be steeper tho.n 12H1! V, DRIVEWAY CURB CUT NOTES: RIGHT-Of-WIIY LINE 'olOEWALI( PLANllNG ::irnl/> 5' 1. SEE SEC. 3.04 K.C.R.S. FOR JOINT REQUIREMENTS. 2. ROLL GUTIER TO MATCH POSITIVE SUPERELEVATION. 3. SEE DRAWING NO. 1-006 FOR CONFIGURATION Of FILL & WAU<.WAY BEHIND CURB IF REQUIRED. 4. FOR INTEGRAL POUR CONSTRUCTION, l/4n EDGED GROOVE MAY REPLACE EXPANSION JOINT AT INTERFACE BETWEEN THE CURB AND ADJACENT SIDEWAf.K. 5. SEE SEC. 3.03 FOR EXTRUDED CURB ANCHORAGE. VARIES RIGHT-OF-WAY LJNE MATCH EXISTING DRI\IEWAY GRA.DE DRIVEWAY CURB CUT NOTES: 1 . 2. 3. 4. 5. SECTION A-A l:D,ENT CONCRETE DR~/EWA'I' 5" THICK FOR WIDTHS OF SIDEWALK SEE SEC. 3.02. FOR WIDTHS OF PAVEMENT AND SHOULDER SEE SECS. 2.02, 2.03, AND 2.04. SHOULDER SHALL BE SURFACED AS REQUIRED BY SECTIONS 3.07 AND 4.01. IF PAVED, SHOULDER SLOPE SHALL MATCH CROWN SLOPE OR .02 FT/FT. FOR CURB AND SIDEWALK JOINTS SEE DWG. NO. 3-001. TRANSITION RAMP SHALL BE TEXTURED BY IMPRINT OF METAL GRID WITH 1 /2" SPACING. CEMENT TRANSITION SECTION A-A CONCRETE SIDEWALK TO ASPHALT SHOULDER EROSION AND SEDIMENTATION CONTROL NOTES 1. Approval of this erosion and sedimentation control (ESC) pion does nat constitute an approval of permanent road or drainage design (e.g. size and location of roads, pipes, restrictors, channels, retention facilities, utilities, etc.). 2, The implementation of these ESC plans and the construction, maintenance, replacement, and upgrading of these ESC facilities is the responsibility of the opplicant/ESC supervisor until all construction is approved. 3. The boundaries of the clearing limits shown on this plan shall be clearly flagged by a continuous length of survey tape (or fencing, if required) prior to construction. During the construction period, no disturbance beyond the clearing limits shall be permitted. The clearing limits shall be maintained by the applicant/ESC supervisor for the duration of construction. 4. The ESC facilities shown on this pion must be constructed prior to or in conjunction with all clearing and grading so as to ensure that the transport of sediment to surface waters, drainage systems, and adjacent properties is minimized. 5. The ESC facilities shown on this pion are the minimum requirements for anticipated site conditions. During the construction period, these ESC facilities shall be upgraded as needed for unexpected storm events and modified to account for changing site conditions (e.g. additional sump pumps, relocation of ditches and silt fences, etc.). 6. The ESC facilities shall be inspected daily by the applicont/ESC supervisor and maintained to ensure continued proper functioning. Written records shall be kept of weekly reviews of the ESC facilities during the wet season (Oct. 1 to April 30) and of monthly reviews during the dry season (May 1 to Sept. 30). 7. Any areas of exposed soils, including roadway embankments, that will not be disturbed for two days durin9 the season or seven days during the dry season shall be immediately stabilized with the approved ESC methods (e.g., seeding, mulching, plastic covering, elc,). wet 8. Any area needing ESC measures, not requiring immediate attention, shall be addressed within fifteen (15) days. 9. The ESC facilities on inactive sites shall be inspected and maintained o minimum of once a month or within 48 hours following a storm event. 10. At no time shall more than one (1) foot of sediment be allowed to accumulate within o catch basin. All catch basins and conveyance lines shall be cleaned prior to paving. The cleaning operation shall not flush sediment-laden water into the downstream system. 11. Stabilized construction entrances and roods shall be installed at the beginning of construction and maintained for the duration of the project. Additional measures, such as wash pads, may be required to ensure that all paved areas are kept clean for the duration of the project. 12. Any permanent flow control facility used as a temporary settling basin shall be modified with the necessary erosion control measures und shall provide adequate storage capacity. If the facility is to function ultimately as an infiltration system, the ternporary facility must be graded so that the bottom and sides are at least three feet above the final grade of the permanent facility. 13. \\Aiere straw mulch for temporary erosion control is required, it shall be applied at o minimum thickness of 2 to 3 inches. 14. Prior to the beginning of the wet season (Oct. 1), all disturbed areas shall be reviewed to identify which ones can be seeded in preparation for the winter rains. Disturbed areas shall be seeded within one week of the beginning of the wet season. A sketch mop of those areas to be seeded and those areas to remain uncovered shall be submitted to the DOES inspector. The ODES inspector can require seeding of additional areas in order to protect surface waters, adjacent properties, or drainage facilities .. MATCH EXISTING OR PROPOSED SURFACE ASPHALT CONCRETE CONSTRUCTION SEQUENCE 1. Arrange and attend a preconstruction meeting with King County DOES Inspections Unit. Call (206) 296-6642. 2. Flag clearing limits and easements. Flag property lines. 3. Post sign with name and phone number of ESC supervisor. 4. Flag all trees that to be saved. 5. Grade and install quarry spall construction entrance. 6. Install silt fencing as shown on the plans. 7. Maintain erosion control measures in accordance with King County standards and manufacturer's recommendations. 8. Relocate surface water controls or erosion control measures, or install new measures so that as site conditions change the erosion and sediment control is always in accordance with the King County Erosion and Sediment Control Standards. 9. Cover all areas that will be unworked for more than seven days during the dry season or two days during the wet season with straw, wood fiber mulch, compost, plastic sheeting or equivalent. 10. Stabilize all areas within seven days of reaching final grade. 11. Seed or sod any areas to remain unworked for more than 30 days. 12. Upon completion of the project, stabilize all disturbed areas and remove BMPs upon approval of the Inspector. King County Department of Development and Environmental Services APPROVAL FOR SITE CONSTRUCTION Review Engineer ENGRCOMP Date Senior Engineer ENGRCOMP Date . DEVELOPMENT ENGINEER APPROVAL Date Comments: REVISIONS: 0 z -a: Ill ~ w (.) 'fl Ct:I w ~~ ~ 'fl c:::, ..... I c:::, z .J:! 0 c:::, I 'fl c:::, ..., co co 'fl -,,.. ~ 0 0 --.. co C\l ~--.. z • 'fl ~ .J:! ~ ~ 'fl w ~ ...., • :::t • 0 . a: 0...., 2; ~ ti) .:l ~~ Q,) w i::i ~ "'"t 0 ~ 0 ,,.. ~ ~ w rr <( ~, ~ ~ ~ t:J, ~ 0 ~ ~ E,.; .,: ~ ,-Cl ..., ~ ~ IQ c:::, 0 ..... ~ 'cf, ~ ~ c:::, ... Cl";) 1'. ~ ..... :::::i ~ >-' C,j 0 w -, 0 0: fL ~ ~ IQ~ ~ c:::, ~ ~ c:::, ~ co I u ~~~ .,: :'Ii IQ ~ ,-Cl It:--.. .... 'fl c:::, r.i "1 ~ ~ ~.::t. t.;;i • ..... ..,;: ~ ~ c:::, N ~~~ i:i.. >-' z < '-' :::J fL fL < DATE: 3L16L07 SCALE: 1 " = 30' DESIGN BY: JJJ DRWN. BY: JJJ APP. BY: FILE No. SHEET 3 OF 3 C CONDITIONS C>F APPROVAL @) King County Department of DeveliJP!llent and Environmental ~;orvices \JOO Oakesdale Ave11u!l SW fle111on, WA 98055.1219 CO:\'DlTJONS OF APPROVAL File No. File Name: LOJS0016 Chau Short Plat .l\fay 2, 2003 January 30, 2004 Application Date: Re\'ision Date: This short subdivision is granted preliminary approval subject to the following Conditions of Approval. These conditions are based on a field visit an<l current information the applic:<.Jnt kis provided about the sbo11 subdi\'ision property. Occasionally, in satisfying the Conditions of Approval, a mor~ definitive land use l1111itation of the propoerty may be re', cl!kd. New information (such as final 1-kulth .ip1xo1·a\ or sen~itive arcc1s rn·icw) may n~quire additional conditions and ui:1y reduce the uumber of lots. t-inal appro\"al will be granted afl<"!r compliance 11·ith the Conditions of Approval. Key codes and guideli111.:s ha1·c been noted 10 prn\"id,: guidance ln pr<..'p.iring the rcquir,:d plans and other docuJllents. Cumµliance ll'ith soJlle of tile following conditions ,viii requir,: that engineering plans be prepared l)y a professional cil"il engineer licensed 1n tlie Stale of\\'ashington I. Title 19A A. The sho11 subdivision ~hall comply with all provisions 0fTitle 19,\. B. Tlie final re\'ie\\" process must be completed prior to recording of the short subdivision. Th<.: Department ofDc\·clopment and Envirornncntal Sen·ices (DOES) strongly recouunends the Finc1l Sl101J Plat be submil_led at least one vear prior to the e.,piration date of the project. The Final SJ1ort Plat submittal package includes'. · I. 1\ surveyed map page (four st'ls) including lot area closure calculations; 2. l-'inal health approval from the King Coumy Health Dcpc1i1ment (different from prelimi11ary health appro\'al); 3. A curre11t short plat ce1"tificate an<l supporting documents (easements, etc.); 4 N1yment of the Final Short Pint submittal fee; 5. 1\ copy oftiiis letter (preliminary ,1pproYal letter) :\ Jiccnsed land sum:yor shall be hired to pr<.:pare the final :,horl subdivision duc11m~nts. Tiles<: <lornmcnts shall comply with all of the following conditions for final appro\·a!: C. All persons lrnving an ownership interest in the subject property are required 1o sig11 !be final short subd[\·ision. D. Jf1110difications to _the ap~rove:I prdimimry site plan {Attachment J) are nec(_Je~ to acc_umphsb engmeern1g design or final short plat, then .i re,·ised prd1m1~:iry s~te plan shall be submitted lo DOES for review and approval. The revised site plans shall be submitted with the engineering plans or the final sho1 ! plat submittal. ~ 2. Surface Willer ;\lnnagcment (KCC 9) 3. 1998 King County Surfoce Waler Design :'o1anu:tl (SWD!\f) A. Thi~ s!10~_subdiv1sion pro~o~al is subject 10 full Drainage Review per seciion I. J ..J .3. f< ma] shu11 subJ11·1s1on :i.pproval slrn!l require full compliance with draioage provisions and :;torm drninage requirements of this section. Cowplia11ce may result in reducing the numb<.:r anJ/or location of lots shown on tl1_e apprnl'ed preliminary shor! subdi\"ision. The conditions outlined below ,1.re s11e-spccific drainage conditions: (1) Core Hequiremcut #1 -Discharge al tlie Natural Lc>cation (2) Core Requirement #2 -Off-Site An:ilysis (3) Core Rct1uirement #3 -flow Comrol (4) Core Rc4uirc111rnt #-1 -Coll\"eyanct: Syste!ll ·----· _,_ (5) Core Jkquirrment #5-Erosion & Scc!in1cntation (\1r1trol (6) Core ffrquircmrnt #6 -P.1aimen,mce :;nd Opnaticrn (7) Core Hcquircmrnt #7 -Fin:incial Guarnntees & L1:1ilility (SJ Cure Requirement i/8 -Water Quality (S 1) Spcdal Requirement #I -Other Adopted Requirements B. Ayrnfe~sional civil ~nginccr Jicen~ed in the State ofW:ishi11b'ton shall prepare a fl:cli~1cal lnformatwn Report and/or engineering plans per Cliapter 2, of the 1998 Kmg County Surface Water Design r\fanual. Health (KCC 13) This proje~t. !s exempt from funlicr King County Heath D<:panment review. However, d mipro\·cments are required from tile Sewer and/o:· ;he Water ~istrid, t!ieJJ verification shall be required from said Districl(s) lhat the u11pru11<:!me11ts have been bonded ancUor installed, prior to fin,11 recordirrn of tlH: shoi"t plat. ~ 4. lload Stand:mls (KCC 14) 1993 King County Hoad Standards, Ordin:ince 11187 Final short ;mbdivi~ion approval shall require full compliance with the provisions set fonh in the King County Road Srnndards including engineering plans fo1 all road lrnpro\·emcnls. The eng[n,:ering plans shall be prepared by a prn/Cssional ci\'il engineer licensed in the State of Washington. DDES strongly n:cornm...:nds the ):ne.inecring Plans be subJ11ittcd at lens! two ve.irs prior lo the expiration chte of the project. A. That por.tion of the i\'orth half of SE l 72"J Street :idjoining the subject propcny shall be 1mproYed to an urban Sub-access standard pcr KCRS Section J .03. B. That ponion of tlie East half of l OG!h A\'cnue SE .idjoining tlle subject property shall be improved to an urban Sub-.icccs~ standard per KCRS Section l .03. 5. 6. 7. .- C D. F. G. IL Tile fol101Yinn 1101 ·-sl1· I! b 1 . ~ L:> ·" cs 10ii·n on the Ima! recorded short subdiYi~ion: 1) 2) \\'amino· Kin 1 C I ... . , . ,,. g ?ur1ty 1~s no res_ponsib!lJty to build, 1m_prove, m_n1J_1_1c1.m or oil'.e1 ,1 is.: sen·1a tl1e private roads contained within or pio, idrng sen JC<:: to the prnp<..'rly described ill tliis sho11 stibdi\'ision Alt! ~r1i,b·ate easen1cn1s and/or tracts to be mnintai 11..:d repaired ·m<.i"or 1e,c11t ytheo\\11~rsofth J l · 1 ' •' h . 1 . . e pnrce s mnng cgal access therl."from ,md r e1r ie1rs, as;1_g11s or successms, unless a11d until such roads o.re llllprored to Kmg CO'"'!Y ,,. ,,,, ,., 1 d . . 0 • • "" ,;dr,u.irus am are ed1cateJ nnd accepted bv Km'°' Coun1y for mnmtenance. - All restrictions, casements, tracts, and their purpose shall be shown on the final r1;cor<led sho11 subdi1·isio11. Building and Construction Starafard.l (Tille 16) Grading. The applicant shall con1ply with all applicable provisions ofKCC 16.82. Fire Code (KCC 17) Sretion 902 of the 1997 Edition of Uniform Fire Code The applicant shal!_obtain the approval of the King County fire Protection Engineer fo'. the ndequacy of the fin: hydr.irn, \\'ater rnain, and fire flow standards ofKCC l 7.08 pnor to recoding of the lots. Zoui11g Cude (KCC 21.\) A. Density and Dimensions (KCC 21 A.12) All lots shall meet tin: density an<l din1t.:11sion~ requirements of the R-8-SO zone classificatioi_i or shall be as sho\rn on the face oft!ie appro\"ed prelimi- nary sho1i subdlY1S1on, wh1ehe\W is la1·gcr. Minor revisions to the short subdi\·ision, which do not result in substanfoi! charH!.CS :.rnJ.lor do not create additional lots may be c1ppru1·cd at tlie dlscr<.:tion of-LUSD. B. StreetTrees(KCC2lA.16) Strct'l trees sh.all be proYide\l alonr: that portion of the rild1t-of-\\··1y for 106 ,1, ' -d -' /\ l"Cnue Soudicast and So111he:1st 172" Sm~ct :1bulling tl1e subject property, pursunnt to tl1e pru,·isiuns of KCC 21 A. l 6.050(E) and KCC 2 !A.16. l :)0, unless existing tn:es c1re shown to be equivalent to t!Jc reqLtircmem of Code. Sec 1101e below. Tile required street trees shall be dcsig11ed as to location and spaciug on the final plan c.ubmitlal. The street trees must b.e inst~lled and insp<.:rted, or ,1. performance bond posted, prior to recordmg of the plat. If a p,;:rfotrnancc bond is posted, the street trees must be (nstalle? an~l_inspected \\'ill1in one year of recording of the plat: At the time of 1ns~iect1on, if the trees arc: found to be instc1lled per tlie appro,·ed plan, a nia~llknance bond must be ,.ubmitted, or the perfonmnce bond replaced with a marntcnanee bond, and held for on-: year. After one year, the maintenance bond n~ay be released afi:er ODES has compkti.::<l a second inspection and detcnrnned tlrnt the trees hare been kept healthy c1n<l thriving. NOTE, I.. KCC 2IA.J 6.050 Lrndseaplng -street frontages. The average w1dth of penmeter lanJscJping along street fru:1tages slrnl! be provided as foJlO\\'S: For single-family subdiYi~ious: a, Trees shall be plan led at ihe rate of one tree for every 40 feet of (rontage along a neighborhood collector street or arterial street. b. ! he trees slrnll be: 1. Locme.d within the street rigllt-oi:way ifpennitted by the eustodial staw or local agency; 2. No more than 20 feet from the street right-of-way line wf1en located within a lot; J. Ma_intainc<l by the adjacent lan<loll'ner unless pilrt of a Coumy nrnmtenance progr<1m; and -1. ~ species approved by the County if located witliin the street nght-of-way c1nd compatible with O\Trlic.id utility lines. c. The trees may be sprcad at irrcgLLiar inten·,lls in order to '.tccomin~date sight dist;1nce requirements for drivewnys and l!ltcrSC'"l"(IOJ]S. 2. KCC 21A.16.l90 Fiuanci:il guarantl·cs. Financial guMantees shall be required consistent ll"ith the prn1·isions of Title 27.A.. Siguifieant Tree ~ctcution-KCC 21 A.38.230 wJ 1ic:h applies to the site, a ddailc~ tree retelllion plan slwll, be :;ubmittcd with the engineering plans for the s:ibJec't P.lat. The tre_c r<.:tc1ll1011 pbn (a[ld engineering plans) sli.i!J be CO.t~s'.:1:11t_w1th the re~wr~·mrnts o.f KCC :2 l:\.JS.230, as well as tlie eoneeptua! trL-: 1.ek11t1_011 plun .1dlli.:h JS par1.ol the hearing record for this project. ;,,..10 ~·ka:m.~ of i_he '.ubJeet prop_cny 1s pl'rrnit!cd until tl1e Jirrn! tree rcienlion plan is <1pplO\e<l by _LliSD. flagg111g and temporary fr·ncing of trees to be retained ~hall be prondcd, comi.>tent \\"iil1 KCC 2 lA.33.2308-1-. The placement of 1rnpen·1ous surface.s. fill llK!trrial, excanitio 11 work, or the stora~e of co11structior1 matenal~ is prohibited 1Yithin the fi:nccd arcns arou~id prescn·ed trees, except for grad mg work pern1ittrd pur:;uam to KCC 21A.38_2JOB-4ci(2). A n?te shnll be placed on the final plat indil'ating that the trees sliown to be retamcci on the tree rct~ntion plan shal_l be m,1int,iincd by the future O\\"ners of the pr?posc<l lots, cons_is(ent with KCC 21 A.33.230I36. (I\'ote th:it the ti·ee ~t'!c_ntion plrn1 s_Jia!l be rncJud~·d as_ part of the final i.:nginecring pl.ins for the ~u.bJe_cr plat.) ll tber<.: are no S1l!r1iJ1caL1t trees as defined b~ccial Overlny !J1stnet on_the site then. this rcqLtiremcnt does 110 t _ggp_ly_ s---- The existii~g house shall_ ~e relllO\":'d or demolished prior to the final apprornl and recordmg_ A demolition p1erm11 shall be obtained prior to demolition. !'ro,·ick 35' payed mdii at tbe intersection of 106'h A venue SE and SE 172 Stred per KCRS Sci.::tion 2.10. Dcdiclle a 25-foot propmy line radius at the intersection of I 06c1, Avenue SE mid SE l 72nJ Sire,·t per KCRS Scctivn 2.10. ,. Ro~id jifi1igalion !'aymrnt S:, . .,lem C. D. Existing roadside obstacle(s) shall be rdocated to pro\·ide a minimum c!cara11cc of 10 fcL't frum th<.: edge uft!ie Inn-el lane to the obstacle(s) per KCRS Section 5. l 1. E Privatc access to Lots 2 and 3 shall be shown .1s a joint-use drivcw.iy 11·act per KCRS Section 3.0!. The trni.::t shall b<.: an undiYlded o\\"ncrship to the lots it serves, and tlie lot owners sbnll be rc,ponsible for its maintenance. The tract shall be 20-feet wide with a 18-foot-\\·ide paved surfoci.: The trnct shall be a minirnum of20 feet in length. UTILITY CONFLICT NOTE: CAUTION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE @ 1-800-424-5555 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSING TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE NOT GUARANTEED AND ARE SUBJECT TO VARIATION. • LEGAL DESCRIPTION LOT 13, BLOCK 4, AKER'S FARMS NO. 5, ACCORDING TO THE PLAT THEREOF, RECORDED IN VOLUME 40 OF PLATS, PAGE 27, IN KING COUNTY, \./ASHINGTON, EXCEPT THE \./EST 170 FT, AS MEASURED ALONG THE NORTH LINE THEREOF J AND EXCEPT THE NORTH 60 FT, OF THE REMAINDER. 9. JO. The applicant shall comply with Road Mitigation Pi1yment System (MPS), by paying the require-d MPS fee as determined by King County Department ofTrnnspo1t1tion, plus an administrative fee. The applicant has an option to eitt1er: A. Pay tl1e MPS fee al final short subdivision n;cor<ling and the MPS administrative fee at final short subdivision 11pplication, or B. Pay the J\fPS fee at building pcm1it issuance 1.1nd tl1e i\'1PS ndministrntive fee at the time of building permit application. If option A is chosen, th...:n the following note shall be sholl"n on the final short plat: J\IPS FEE :\"OTICE: All foes required by King County code 14. -;s, Mitigation Payment System (.t'..f PS) have bc<.:!l paid. If option I3 is chosen, then the following note shnll be shown on the fin.ii sh.ort plat: i\1PS FEE NOTICE: Tliis short plat is subject !o King County Code: No. 14.75, King County l{ond l'vlitigntion Pay1n..:nt System (:\,JPS). The /l!PS fees plus the lv!PS adrninistraliYc fee slrnl! be paid ut the time of building pcrn1it application at the rate in effect a! that time. Stair En\·iromuc·ntal Potic~· Ad (SEP,\) This short subdivision w,is cxe!llpt from the provision oftlie State En1·ironmental Policy Act (SEP,\). Other Cousiderntions Preliminary approval of this application Joes not limit the applic:mt's responsibility to obt:iin any requirl:d permit or license from the State or otlier regulatory body .. This may includ<.: obtaming a forest practice permit from tbe Washington State Department of Natural Resources for tree rcrno\'al. VERTICAL DATUM• NAD 83, PER \./SDDT GEOGRAPHICAL INFORMATION REPORT BENCHMARK, CONCRETE MONUMENT IN CASE \.I I A BRASS PLUG @ THE INTERSECTION OF SR 515 & SE lBOth ST, ELEVATION = 402.09' PER \./SDDT GEOGRAPHICAL SERVICES SURVEY MARK REPORT, MONUMENT I.D. #2606 AND DESIGNATION #IS 1765, Vici n it y M a p .5 \ r;Prl t N Soils Map Notice Required Contractors shall notify operators who maintain underground utility lines in the area of proposed excavation or blasting at least two business days, but not more than ten working days prior to commencement of excavation or demolition in accordance with RCW Title 19. Names and telep[1one numbers of the operators of underground uti!ity lines in this project appear below. These numbers shal! also be used to serve in an emergency conditions as required. Phone SOOS CR[EK WATER & SEWER DIST. (253) 630-9900 Sanitary Sewer SOOS CREEK WATER & SEWER DIST. (253) 630-9900 Water District PUGET SOUND ENERGY ( 425) 454-6363 Gas Company PUGET SOUND ENERGY (253) 395--6915 Power Company Call Before You Dig DIAL-A-DIG 1-800-424-5555 Notes 1. The Developer is required to notify the Land Use Services Division, Land Use Inspection Section (206) 296-6642, three days prior to the beginning of construction for a preconstruction conference and specifically request inspection before beginnlng: A. Installing siltation and erosion control measures B. Clearing and grubbing C. Earthwork D. Installation of any underground utility E. Before placing subbase, base or paving surfaces F. Installation of any forms or placlng any concrete 2. A permit must be obtained from the office of the Resident Engineer, Washington State Department of Transportation, before ony construction is started on any existing stole route. 3. A Hydraulic Project Approval (HPA) Permit must be obtained from the Washington State Department of Fisheries prior to any work when required. Bonding Information Restoration Bond Amount $ -------- Performance Bond Amount $ -------- I I I Site Plan Approval Approval of these plans is for construction of road and drainage improvements, site drainage & grading and temporary erosion control in unincorporated King County only. These plans do not authorize any other utility approval or improvements proposed in any State right of way. Site pion approval is void if the commercial building permit hos not been obtained or renewed within two years of approval. Subdivision pion approval is void if the finol plat is not recorded prior to the preliminary plat approval expiration. ASSESSORS NO.: 008700-0280 PRO RATA SHARE ASSESSMENT ANALYSIS (County Use Only) Section Township Range Tox Parcel Number 2 91 1213 I I 0141 I o 10 I 8 17 I o 10 I o 12 I s Io I Site Locatlon Is within the _ GR_EEt::!Js!VER dralnage shed(s) Pro Rota Share Assessment(s) ore: O Required D Not Required from the site due to development Peak Runoff Assessment Rote($ Peak Volume Assessment Rote($ for increased storm water runoff. ) per c.f.s. lncreases.(10 year, 2 hour storm) ) per Ac. Ft. increoses.(2 year, 2 hour storm) AGREEMENTS, PLAN REFERENCES, PERMITS ETC. (To be completed by Consultant) Preliminary Plat Approval/Permit Issued Date: MARCH 12, 2004 Expiration Dote: MARCH 12, 2009 Other Related Permit Numbers Received: Right-of-Way Use Permit Grading Building/Structural Other ______________ _ Boord feet of tree removal on site: NONE Cubic yards of material houled on/off the site: ------ Is this a erosion sensitive areo site? (Yes/No): __ N_D __ _ Note: If "yes", a Highly Sensitive Site Erosion Control Supervisor is required. See ESC plan and TIR for details. Date Ernergency 911 Police-Fire-Rescue RECOMMENDED FOR APPROVAL (To be completed by King County) Engineer Plan Reviewer Engineer Supervisor Traffic & Planning Engineer Sensitive Areas Structural Review Engineer Other APPROVED FOR CONSTRUCTION DEPARTMENT OF DEVELOPMENT & ENVIRONMENTAL SERVICES Date ,Q. -<= ~ L ~ Q) Q) -C C 'I) " " :, oor= BJD TJ L Q) §?., :: ~ L <I) " C O! L L V :, 0 (J) L C ow D [8 King County, Washington James H. Sanders, P.E. Development Engineer PROJECT CONTACT INFORMATION ___ H_A_Af._I_N_H_C_H_A_ll __ _,,(425) 643-3993 Name 4101 150th AVE. SE BELLEVUE, WA. 98006 Address and Zip Code Phone D A Partnership :0 An Individual __ _:H:.:::A=-Af.=.cIN~H:.......:C-=H=A.::..lJ=--_ __;:( 425) 6 43-3993 Name 4101 150th AVE. SE Phone BELLEVUE WA. 98006 Address and Zip Code D A Corporation D A Partnership C8: An Individual _J_A_E_G'-E=R.:__:E.c..-N..c..G=-:Icc.Nc.::E=E=R:..::I:.::_N:...::G=----->:( 253) 850-0934 Name Phone 9419 S. 204 PL. KENT 98031 Address and Zip Code Lo S Z1 ~-------'--'--- L C, 0 CJ) z > L -<I) a: o._ ::J w qi (/) CJ '-...._ w (I! L 0:: ~ <I) z t~ (1) ~ C C -..., cx::i ,-C, CJ) '::j, o:i C c::, w z C\l '-...._ • ..,-, w ~~ (.) <I) ..., ..,-, ::.:1 • ..c a: 0..., \fl § (.) w L ~~ <( C, ~ C '::j, CJ) w ~ CJ) <I) <( 0 "") sf" r<) CF> 0 I 0 co co w a.: 0::: w CC) w <( -, -j (J) w ::;; <( -, (1) C 0 ..c Q. L 0 +-' 0 C -0 L 0 0 u ..,-, (.) <I) ,-, 0 L Q. ~ [E~[E~~rEID) APR O 9 2007 K.C. D.D.E.S. ~ ~ ~ ~ c::, c::, \fl (;I') (/) c::, ~ O::'. w m = L L 0 <I) <I) z :=) _{) _{) z E E ..,-, C w ::J ::J (1) _J z z E LL >, ..,-, o._ ..,-, (.) 0 (/) > <I) w •-, <I) 0 ..,-, 0 > (.) L (1) 0 <( Q. 0 License/Seal Sheet 1 of 3 ---PROFILE @ EX. 1ST -· . ~-390 .c NORTH PVMT. EDG g__ !;';"'~;-----------'-----~------··--------w i,,------- 0 ·~~---"----_390 ,-~--r----;:=B'=n·-·cp P-@ 28. 3 , ~ PROFILE @ PROPO ED -~ . d CURB FLOW LINE ~ -- 0 -- _... 0 --385 _ ~+---------~t---+-+----..,-=:;---t--c:?"--F---------=+-"-=--- 380 ->------~------,.,-, ' ~ET ---te.~386-:-cl-+---- 2+66, 91, 26.2' LT CB 1 TYPE 1 RIM: 388.0 IE: 385.0 385 380 375 375 ---1---------·1----------1--'='--'--'"'---I 370 1 +52.39, 21.2' LT CB #2 (TYPE 1) RIM: 380.91 IE: 377.9 f-----------------+ 1+00 390_ -0 C I-"'----..... ~ _J 0 0 0 385 + 0 380 375 370 10+00 SCALE: 1" 1 " 20' HORZ. 5' VERT. m· Q:'. d 0 Cl. .... ' N (J) >A + 0 ~ SE 2+00 172nd ST. (URBAN SUB ACCESS) PROFILE @ EXIST /EAST PYMT. EDGE I PROFILE.@ PROPOSED CURB FLOW LINE ' I 4,6% -~c----~ ' --1.:...---= I -re .. - ' SCALE: 1 " 1" - VARIES 5' ' . I " '" . ' ~~ ,_ -•'; ···--"' LO' PT OF CURB CB #3 (TYPE. 1) RIM 377.1 IE: 375.5 (EX. 12") IE: 375.4 (NEW 12") SE OYER EXIST. 12" CD ... N Ol ..... (J) ..... ..... n n 11+00 20' HORZ. 5' VERT. 106th AVE. SE (URBAN SUB ACCESS) 30' 12' f-z w :::; ~ <( Cl. ~ VARIES f--~-t->-----------i i-,-------------~-i----- SIDEWALK 0.5' 2% Cl. 0 w VARIES ±7.5' (106th) SAW CUT I' INSIDE EX PVMT (10 th) INSIDE E . PVMT. (17 nd) ui ~ 0 u §I I w <D (J) ... .:.. ~ -- n ... ~ ro n r:-~-:i:-l.:·~·:':' .!.· -& . ~'?--+ ., • 't'.' 4" THICK / CONC. WALK 4' (172nd) 2.0% .L..-EXIST! G PAVEMENT EXISTING PAVEMENT 106th) VERTICAL CONC. CURB & GUTIER CROSS SECTION SE 172nd ST. & 106th A VE (URBAN SUB ACCESS) N.T.S. 2" CLASS "B" ASPHALT CONCRETE 1.5" COMPACTED DEPTH CRUSHED SURFACING TOP COURSE 5" COMPACTED DEPTH S'fi:\ CRUSHED SURFACING BASE COUSE = \__ADDITIONAL GRAVEL MAY BE REQUIRED DEPENDING ON SOIL CONDITIONS 390 385 380 375 370 172nd) 370 3+00 STREET TREE -WESTERN LARCH (LARIX OCCIDENTALIS) PLANTED 5' FROM R.O. W. LINE ( 4 TREES) @ 12' RCP f! INV=369.7 ,, I n5" r 1/4" EDGED 1 -GROOVE /"R\ 2.0% ~I .. · .. ,, . 5. 0% _ lb _l .__:.;. <L_ ~··-·~:_,_·_·~·_ .. _._ .. _,~~ ... ~: )s" 18" OR 24" I ,-~~~ *NOTE. TOP OF CURB @DRIVEWAYS CEMENT CONCRETE VERTICAL CURB AND GUTTER NOT TO SCALE A PORTION OF THE SW 1/4 OF SECTION 29, TWP. 23 N., AGE. 4 E., W.M. EX. 12' CCP INV=381.5 BLOCK 4 AKER'S FARMS ND. 5 VOL 40, PAGE 27 LDT 12 w z ::J f- 0 _J 1' ~ FLOW LINE TO BE ~ DIRECTED TO CATCH BASIN AS SHOWN ON PLAN 20' w z TRACT ::J f- 0 18' 1 ' _J ~ A.C. PAVEMENT 2 1 /2" MIN. COMPACTED DEPTH CRUSHED SURFACING BASE COURSE 300.01' (CALC) 300' (PLAT) ADDITIONAL TREATMENT MAY BE REQUIRED DEPENDING ON SOIL CONDITIONS. SEE SEC. 4.02 SSMH RIM=376.5 NOTE: 130.01' 1 +52.39, 21.2' LT CB #2 (TYPE 1) RIM: 380.91 IE: 377.9 1. TRACT "A' IS A JOINT USE DRIVEWAY TRACT TO BE JOINTLY OWNED AND MAINTAINED BY LOTS #2 AND #3. 2. EXISTING WATER MAIN SHALL BE LOCATED BY POTHOLING PRIOR TO INSTALLATION OF DRAINAGE SYSTEM. 20 a ~ 12' CDNC, RET. \./ ALL \./ITH \./ODD FENCE (\./ALL ON PROP. LN.) GRAPHIC SCALE 10 20 40 i i b ( IN FEET ) 1 inch = 20 ft. co (\J 1-- _ _1 I LDT 13 I EX HOUSE I I L __ _ TRACT "A" JOINT USE DRIVEWAY TRACT N.T.S. STREET TREE -WESTERN LARCH (LARIX OCCIDENTALIS) PLANTED 5' INSIDE OF R.D. W, LINE ( 4 TREES) King County Department of Development ond Environmental Services APPROVAL FOR SITE CONSTRUCTION Review Engineer ENGRCOMP Date Senior Engineer ENGRCOMP Date BO , DEVELOPMENT ENGINEER APPROVAL Date Comments: REVISIONS: h ~ h ~ j ~ >l., 0 ~ ~ ~ ~ -,: :S >l:; h to ~ 0 0 ..... ~ .... tB C') ~ 12 ~ ..... ~ ::::i ~ ,:c Cj 0 w , 0 "' <l. in ~ to 0:, ~c:,O:. ~ 0 C"J • 0:, Ji u ~ 0:, "" -,: :"i to ~ ..q ~......_ ' lr,) C .. C\) ~ ~~:!,- -. r.:i c ~ c:j2: ;; ~ . ~ ,:c z <( 0 :::; <l. <l. <( DATE: 3/16/07 SCALE: 1" = 30' DESIGN BY: JJJ DRWN. BY: JJJ APP. BY: FILE No. SHEET 2 OF 3 GENERAL NOTES 1. All construction shall be in accordance with the King County Code (KCC), Road Standards (KCRS), and the King County council's conditions of preliminary subdivision approval. It shall be the sole responsibility of the applicant and the profussional civil engineer to correct any error, omission, or variation from the above requirements found in these plans. All corrections shall be at no additional cost or liability to King County. 2. The design elements within these plans have been reviewed according to the King County Department of Development and Environmental Services (DDES) Engineering Review checklist. Some elements may have been overlooked or missed by the DDES plan reviewer. Any variance from adopted standards is not allowed unless specifically approved by King County prior to construction. 3. Approval of lhis road, grading, and drainage plan does not constitute an approval of any other construction (e.g. domestic water conveyance, sewer conveyance, gas, electrical, etc.) 4. Before any construction or development activity, a pre-construction meeting must be held between the DDES's Development Inspection Unit, the Applicant, and the Applicant's Construction Representative. 5. A copy of these approved plans must be on the job site whenever construction is in progress. 6. Conslruction noise shall be limited as per King County Code (Section 12.88); normally, this is 7 a.m. to 10 p.m. weekdays and 9 a.m. to 10 p.m. on weekends. 7. It shall be the applicant's/contractor's responsibility to obtain all construction easements necessary before initiating off-site work within the road rights-of-way. 8. Francl1ised utilities or other installations that are not shown on these approved plans shall not be constructed unless an approved set of plans that meet all requirements of KCRS Chapter 8 are submitted to the DDES's Development Inspection Unit three days prior to construction. 9. Datum shall be KCAS unless otherwise approved by ODES. 1 o. Groundwater system construction shall be within a right-of-way or appropriate drainage easernent, but not underneath the roadway section. All groundwater systems must be constructed in accorclance with Section B1 3.02 of the APWA Slandard Specifications. 11. All utility trenches shall be back filled and compacted to 95 percent density. 12. All roadway subgrade shall be back filled and compacted to 95 percent density (WSDOT 2-06.3). 13. Opell cutting of existing roadways is not allowed unless specifically approved by DDES and noted on these approved plans. Any open cut shall be restored in accordance with KCRS B.03(8)3. 14. The Contractor shall be responsible for providing adequate safeguards, safety devices, protective equipment, fiaggers, and any other needed actions to protect the life, health, and safety of the public, and to protect property in connection with the performance of work covered by the contractor. Any work within the traveled right-of-way that may inturrupt normal traffic flow shall require at least one flagger for each lane of traffic affected. All sections of the WSDOT Standard Specifications 1-07.23 -Traffic Control, shall apply. DRAINAGE NOTES 1. Proof of liability insurance shall be submitted to ODES prior to the pre-construction meeting (KCC 9.04.100.D). 2. All pipe and appurtenances shall be laid on a properly prepared foundation in accordance with WSDOT 7-02.3(1). This shall include leveling and coll\pacting the trench bottom, the top of the foundation material, cind any required pipe bedding, to a uniform grade so that the entire pipe is supported by a uniformly dense unyielding base. 3. Steel pipe shall be galvanized and have asphalt treatment #1 or better inside and outside (KCRS 7.03) 4. All draim1ge structures, such as catch basins and manholes, not located within a traveled roadway or sidewalk, shall hav<o" solid locking lids. All drainage structures associated with a permanent retention/detention facility shall have solid locking lids (KCRS 7.05). 5. All catch basin grates shall conform to KCRS drawing numbers 2-013, 2-018, 2-019, or 2-020, which includes the stamping "OUTFALL TO STREAM, DUMP NO POLLUTANTS" and "Property of King County" (KCRS 7.05). 6. All driveway culverts localed within King County right-of-way shall be of sufficient length to provide a minimum 3:1 slope from the edge of the driveway to the bottom of the ditch. Culverts shall have beveled end sections to match the side slope (KCRS 7.03(L), Drawing No.2-001). 7. Rock for erosion protection of roadway ditches, where required. must be of sound quarry rock, placed to a depth of 1 foot, and must meet the following specifications: 4"-8" rock/40%-70% passing; 2''-4'' rock/30%-40% passing; and-?' rock/10%.20% passing. Installation shall be in accordanco with KCRS 7.02(B) drawing number 2"024. 8. Drainagu outlets (stub-outs) shall be provided for each individual lot, except for those lots approved for infiltration by King County. Stub-outs shall confor'rn lo the following: a) Each ot1tlet shall be suitably located at the !owes! elevation on the lot, so as to service all future roof downspouts and footing drains, driveways, yard drain1a, and any other surface or subsurface drains necessary to render the Jots suitable for their intended use Each outlet shall have free-flowing, positive drainage to an approved storm water conveyance system or to an approved outfall location b) Outlets on each lot shall be located with a five-foot-high, 2'' x 4" stake marked "storm" or "drain". The stub·out shall extend above surface level, be visible, nnd be secured to the slake. c) Pipe material shall conform to under drain specifications described in KCRS 7.04 and, if non-metalllc, the pipe shall contain wire or other acceptable detection d) Drainage easements are required for drainage systems designed to convey flows through individual lots. e) The applicant/contractor is responsible for coordinating the !ocat1ons of all stub-out conveyance lines with respect to the utilities (e.g. power, gas, telephone, television). f) All individual stub-outs shall be privately owned and maintained by the lot homeowner. DETECTABLE YARNING PATTERN (SEE DETAIL) 4' -01 MIN. 6 1 -01 MIN. /8' EXPANSION JOINT (TYP.l TD, PLAN F -3) A SIDE\,/ ALK NOTES , I RAMP PLAN CEMENT CROSSYALK (TYP.) / (SEE STD, PLAN H-5c) TYPE lA LANDING RAMP '-0~ • , TOP OF ~' 2 %._:j~._,-"---_:l :==---u ROADYAY CDNCRET!c: J f 7--~\_ S!DEYALK DETECTABLE YARNING DEPRESSED PATTERN (SEE DETAIL) frtl Jor~TJfR SECTION (A; ·-· I 6' -O' MIN, 1 ~- ' TOP OF ~•· 2% _ ,, ~-~ROADYAY CEMENT CONCRETE 7 \_ S!DEYALK CEMENT CONCRETE (~B ) CURB & GUTTER SECTION <SEE NOTE 3l L Avolcl plc;clng clrc;inc;ge structures, junction boxes or other obstructions In front of rc;Mp c;ccess c;rec;s, 2, Detectc;ble wc;rnlng pcdterns shc;ll be texturecl using truncc; teci cioMe pc; ttern <see cletc;ll). 3. Curb c;nci gutter shown, see the Contrc;ct Plc;ns for the curb cleslgn speclflecl. See Stci. Plc;n F-1 for curb cletc;lls. 4. The plc;n views for SIDE\./ALK RAMP TYPES 1B, !C & 1D are provlclecl to define ec;ch rc;Mp type. See the RAMP DETAIL on this sheet. See Stci, Plc;n F -3 for slclewc;lk joint plc;ceMent c;nci cletc;lls. 5. Ra Mp slopes shc;ll not be steeper thc;n 12H1l V. DRIVEWAY CURB CUT NOTES: RICKT-OF-W,W LINE 1. SEE SEC. 3.04 K.C.R.S. FOR JOINT REQUIREMENTS. PLANTING smu' VARIES 5' 1-().D'i. fi. ft. 2. ROLL GUTTER TO MATCH POSITIVE SUPERELEVATION. 3. SEE DRAWING NO. 1-006 FOR CONFIGURATION Of FILL & WAJ.Y..WAY BEHIND CURB IF REQUIRED. 4. FOR INTEGRAL POUR CONSTRUCTION, 1/4H EDGED GROOVE MAY REPLACE EXPANSION JOINT AT INTERFACE BEJWEEN THE CURB ANO ADJACENT SIDEWALK. 5. SEE SEC. 3.03 FOR EXTRUDED CURB ANCHORAGE. VAAIES RIGI-H-Of-WAY UNE W.TCH EXISTING DRIVEYIAY GAADE DRIVEWAY CURB CUT NOTES: 1. 2. 3. 4. 5. SECTION A-A CEMENT CONCRETE DRIVEWAY 5" Tl-llCK FOR WIDTHS OF SIDEWALK SEE SEC. :l.02. ' FOR WIDTHS OF PAVEMENT AND SHOULDER SEE SECS. 2.02, 2.03, AND 2.04. SHOULDER SHALL BE SURFACED AS REQUIRED BY SECTIONS 3.07 AND 4.01. IF PAVED, SHOULDER SLOPE SHALL MATCH CROWN SLOPE OR .02 FT/FT. FOR CURB AND SIDEWALK JOINTS SEE DWG. NO. 3-001. TRANSITION RAMP SHALL BE TEXTURED BY IMPRINT OF METAL GRID WITH 1 /2" SPACING. 4" CEMENT CONCRETE SIDEWALK AND RAMP ••. .<l • ~ •• • 6'-D" MIN. 12 SECTION A-A CEMENT TRANSITION CONCRETE SIDEWALK TO ASPHALT SHOULDER EROSION AND SEDIMENTATION CONTROL NOTES 1. Approval of this erosion and sedimentation control (ESC) plan does not constitute on approval of permanent road or drainage design (e.g. size and location of roads, pipes, restrictors, channels, retention facilities, utilities, etc.). 2. The implementation of these ESC plans and the construction, maintenance, replacement, and upgrading of these ESC facilities is the responsibility of the applicont/ESC supervisor until all construction is approved. 3. The boundaries of the clearing limits shown on this plan shall be clearly flagged by a continuous length of survey tape (or fencing, if required) prior to construction. During the construction period, no disturbance beyond the clearing limits shall be permitted. The clearing limits shall be maintained by the opplicant/ESC supervisor for the duration of construction. 4. The ESC facilities shown on this pion must be constructed prior to or in conjunction with all clearing and grading so as to ensure that the transport of sediment to surface waters, drainage systerns, and adjacent properties is minimized. 5. The ESC facilities shown on this pion are the minimum construction period, these ESC facilities shall be upgraded account for changing site conditions (e.g. additional sump requirements for anticipated site conditions. as needed for unexpected storm events and pumps, relocation of ditches and silt fences, During the modified to etc.). 6. The ESC facilities shall be inspected daily by the opplicant/ESC supervisor and maintained to ensure continued proper functioning. Written records shall be kept of weekly reviews of the ESC facilities during the wet season (Oct. 1 to April 30) and of monthly reviews during the dry season (May 1 to Sept. 30). 7. Any areas of exposed soils, including roadway embankrnents, that will not be disturbed for two days durin9 the season or seven days during the dry season shall be immediately stabilized with the approved ESC methods (e.g., seeding, mulching, plastic covering, etc.). wet 8. Any area needing ESC measures, not requiring immediate attention, shall be addressed within fifteen (15) days. 9. The ESC facilities on inactive sites shall be inspected and maintained a rninimum of once a month or within 48 hours following a storm event. 10. At no time shall mare than one (1) foot of sediment be allowed to accumulate within a catch basin. All catch basins and conveyance lines shall be cleaned prior to paving. The cleaning operation shall not flush sediment-laden water into the downstream system. 11. Stabilized construction entrances and roads shall be installed at the beginning of construction and maintained for the duration of the project. Additional measures, such as wash pads, may be required to ensure that all paved areas are kept clean for the duration of the project. 12. Any permanent flow control facility used as a temporary settling basin shall be modified with the necessary erosion control measuros and shall provide adequate storage capacity. If the facility is to function ultimately as an infiltration system, the ternporary facility rnust be graded so that the bottorn and sides are at least three feet above the final grade of the permanent facility. 13. \\here straw mulch for temporary erosion control is required, it shall be applied at a minimum thickness of 2 to 3 inches. 14. Prior to the beginning of the we\ season (Oct. 1), all disturbed areas shall be reviewed to identify which ones can be seeded in preparation for the winter rains. Disturbed areas shall be seeded within one week of the beginning of the wet season. A sketch map of those areas to be seeded and those areas to remain uncovered shall be submitted to the DOES inspector. The ODES inspector can require seeding of additional areas in order to protect surface waters, adjacent properties, or drainage facilities. MATCH EXISTING OR PROPOSED SURFACE ASPHALT CONCRETE C01VSTRUCTION SEQUENCE 1. Arrange and attend a preconstruction meeting with King County DOES Inspections Unit Call (206) 296-6642. 2. Flag clearing limits and easements. Flag property lines. 3. Post sign with name and phone number of ESC supervisor. 4. Flag all trees that to be saved. 5. Grade and install quarry spall construction entrance. 6. Install silt fencing as shown on the plans. 7. Maintain erosion control measures in accordance with King County standards and manufacturer's recommendations. 8. Relocate surface water controls or erosion control measures, or install new measures so that as site conditions change the erosion and sediment control is always in accordance with the King County Erosion and Sediment Control Standards. 9. Cover all areas that will be unworked for more than seven days during the dry season or two days during the wet season with straw, wood fiber mulch, compost, plastic sheeting or equivalent. 10. Stabilize all areas within seven days of reaching final grade. 11. Seed or sod any areas to remain unworked for more than 30 days. 12. Upon completion of the project, stabilize all disturbed areas and remove BMPs upon approval of the Inspector. King County Department of Development and Environmental Services APPROVAL FOR SITE CONSTRUCTION Review Engineer Senior Engineer DEVELOPMENT ENGINEER Comments: ENGRCOMP Date ENGRCOMP Date APPROVAL Date ,:.: u w -, 0 "' IL ,:.: z < 0 :, IL IL < REVISIONS: C, z -a: w w z -C, z w ~ ~ f;j a~ ~ ..,: (I) :S E-. ~ 0 ... i..;i "I< in C ~ t,. ... ~ ~ (..) in ~ <o Ol f;j C Ol ~ C in ~~~ u ..,: :<Ii <o ~ ..c: lit= IQ' c c.i t\/ ~ ~§:i~ r.:i • ... "-1 ~ ~ ON ~ [iJ . ~ Cr.l ~ l'-, ><I ~ ~ ~ E-< ~ DATE: 3/_16/_07 SCALE: 1." = 30' DESIGN BY: JJJ DRWN, BY: JJJ APP. BY: FILE No. SHEET 3 OF 3 CONDITIONS ()F APPROVAL ® King County Department of Do~vloprnent and Environmental Services 900 Oakesdale Avenue SW Rer,lon, WA 98055-1219 File No. File Name: Application Dalt': Revision Date: COi\DITIONS OF APPROVAL LOJSOOIG Chau Short Pbt May 2, 2003 January 30, 2004 This short subdifision is granted preliminary approya\ subject to tile following Conditions of Appronil. The~e conditions are basi::d on a field visit and current inforrnatiun tbe applicant has pro\·lded about the short subdiYision property. Occasionally, in satisfying the Conditions of Appro\·al, a wore definitlve land use limitation of the property may be r1;n:akd. New information (sucl1 as final Health appro\'al or sensiti\'e an:Ll~ re1·iew) m:iy n:quire additional conditions and 111ay reduce the number of lots. F. G. II. The follo11 ing notes skill be sho11 non tlie Jina[ recorded short subdi1·ision: I) 2) Warning· Kin,, Coun()' ]'as 10 ,-·b·1· b · . . . · ;~ . . 1 f1,:spons1 1 tty to udd, 1mprol'e ma11_1_1a_m or olhcrmse scrYice the priv;1te rands eontained within' or pro\idrng scn·i,·c to thi: µropeny described i11 this sl1ort subdi\"tsion. ~ll ~riYa!e ea~,·111...:nts antllor tracts to bi: maintained, repaired anci/or r1..bw!tbytheu1 1·i·. 1·1, ·»[ 1 . ' . . r us o ne pa!i.:c s 1a1·mg le<>a! access therefrom,, <l their hel!"~ ·1s, · ~ . 0 <.Il . . , ' "igri., or successors, unless and until such roads are llllp:o\·..:;d to K111g c·o,,,,ty ,[••,,d, <l-I d ct· d . , . -" "r ~ a11l are e 1cate and accepted by Krng Cou11ty JClr mainte1rnnee. Allutilitie$wiLhin,,ro1,, .. <l · It· 1-I II' . y 1 ~e 11g l s-o -\\ ay s 1a ws.: llleluJ<cd within a fr-trcl · ·, approi:ed by th...: Kmg County Cmmcil prior to Jina! short subdi\·ision ' ' iise r1ccordmg. All restrictions, easements, tracts, and their purpose shall be shown on the final recon.led sl101i subdi\·io.ion. Final .:ipproYal will be gra11ted after complianci: with the Conditions of Approval. Key codes and guidelines 111 11·r: been noteJ to pro1·ide guidan_-:e in p1·eparing the required plclns and other documents. Co111pliam:e with some of the following conditions \\"ill requm:: that cngineermg plans be prcpan:d by a professional ciYil cuginccr licensed in (he State of Washington. 5. Building and Construction St:1ndards (Titk 16) L Title 19,\ Grading. The applicant shall comply with all applicable provisions ofKCC 16.82. A. Tl1e shon subdivision shall comply wiih rd] proYisiuns of Title l9A 6. Fire Code (KCC 17) B. Tl1e final n:,·iew process must be compkted prior to recording of the sho1i subdivision. The Depanment ofDeYe]opment nnd Environmental Serl'ices (J)DES) strongly recomms.:nds the Final ~hOl't Plat be sul:mitted al least one y,;.ar prior to the exnirn(io:i dclte of the prok..9. The Final Short Pl.it submittal p;1c.:kage lncludes: Sr:ction 901 of the 1997 Cdiriou ofUuiform Fire Code The applicant shall obrnin tlie <lpprurnl of the King County Fire Protection Engineer for the adequacy ofihe fire hydnml, \\'alcr main, and fire flow standards ofKCC 17.08 prior to recoding of the lots. J. A surYeyed map page (four sets) im:luding lot area closure calculations; 7. Zoning Code (KCC 21.-\) 2. Final h1..·alth approval from the King County Health Dep:uimenl (different from prdiminary health approv.i.l): J, A current short plat certificate and supponiug documents (ease1m:nt:;, etc.); :\, Payment of the final Short Plat submitt,d fee; 5. A copy of this lel!er (preliminary appro\·:d letter). A licenseJ land surveyor shall be hiroed to prepare the fimd short subdivlsion documents. These docrnnents shall comply with al! of the following conditions for final appro1·al: C. 1:-ll persons having an o:n~e:ship interest in the subject property .ire required to sign the final short subdll"lston. D. If modifications to the approved preliminary site plan (Attachment]) are uee~cd to acc_omplish engineering design or final short plat, then a revised !1relim1~al)1 site plan shall be submitted to DDES for review and apprornl. J he revised site plans shall be submitted with the engineering plans or the final sl10rt plat submittal. - 2. Surface Water :\fa1rngement (KCC 9) 1Y98 Kii1g County Surface Water Design -'lauual (SWD:\f) A. This short.subdivision proposal is subject to Full Drainage Review per section J I :2.3. F111al. s!iort subdi,·ision appro\"al shall require full compliance with drainage p1ons10ns and storm drnimige requiremi.:nls ofd1is section. Compliance may result in reducing the number andlor location of lots shown ull the approved prdimina1y sl1ort subdi\·ision. The conditions outlined below <ffC site-specific drainage conditions: (I) Core Requirement #1 • Disckirge ;it tlie Natural Loi.::ition (J) Core Requirement #3 w Flow Control (,)) Core Requirement #4 -Co111"eyance Systcru (5) Cocc Rcqoircrnrnt #5 -Ernsion & Sc<lin,cmalion CrnH,ol (6) Core Requircm011t #6 -.\lainte11,1I1LT and Oper:1tiun (7) Core Requirement #7 -Financi~il Gu.irnntees & Li~ibility (8) Corl' Requireml'llt #8 -Wat1.:r Qu:ility (SI) Spcciul Rc,quirement #1 • Other Adopted Requirements B. A.1,nofe~siunal _ci\·il e_ngineer liccnsc.:d in the State of Washington shall pr1.:pare a I echrncal Information Report and/or engineering plans per C!iapt1.:r 2, ofthe 1998 King County Surface Water Design Manual. 3. Health (KCC 13) This project is exempt from further King County Heath Dep2rtment review. J-lol\'el'er, ifirnpr\l'."Cllll'Jlls me rcqt1i1·ed frorci tlic Sewer :nuJ'o:· ihe Watet· District, tl1en \"erilkatlon shall be required from said District(s) that the improvements have been bon<l~d .indior installed, prior to final recordine: of the short plat. ~ 4. Road Standards (KCC 1-l) 199] King County Road St:rndards, Ordinance 11187 Final short Subdivision approval shall require full compliance with the provisions set forth in the King County Road St,rndards inc!l1ding engineering plans for all road improvements. The enginee1·ing plans shall be prepared by a profes~ional c:l\·il engiueer licensed in the State of Washington. DOES strongly recornrn,;;nds the b1l!.ineerinR Plans be submitted at kast two 1-ears prior to thi.: expiration date oftl1e NQiect A. That portion of the North half of SE 1 72''J Street adjoining the subject prope1ty shall be impro\"ed to an urban Sub-access standard per KCRS Section 1.03. B. That po11ion of tbe East lia!f of 106 11, .. henue SE adjoini11g the subject prope1ty · shall be improved to an urban Sub-access standard per KCRS Section 1.03. C. D. A. Denslty anJ Dimensions (KCC 21A12) All lots shall meet the dcnsity and dimensions requirements of the R-8-SO zone classifiecition or ~hall be as shown on the face oftlic approYed prelimi- nary shurt subdi1·ision, wiliche\'cr is larger. l\linor revisions to the short subdi_1'ision, \Yhich do not result in substantial changes and/or do not create add1twnal lots m:iy b1.: appro\·ed at tbc dlscretion ofLUSD. B. S!rc·e!Tm.'s(KCC21A.16) Stn:d trees shall b<.: pro1 ided along thctt ponion of the right·of-way for lOG'li An>irne Southeast :md Soutlic:i,;t 172"d Street abutting the subject property. pur~uant to the pro\·isions of KCC 21 A. l 6.050(E) and KCC 21A.16.190, unless e:.i~1ing tiees :lre shown 10 be equi1·alcnt to the requiremcn! of Code. See note b(:low. Tl1e required ~tree! trees shall be designed as to loc::ition <rnd spacing on the Jina] pl.in submittal. T11e street trees must be installed and inopeei<.::d. or a performance bond posted, prior to recording of the plm. If a performance bond is posted, tlie street trees must be installed and inspected within one year of recording of the plat. At the time of inspection, if the trees a1 e found to be installed per the approved plan, a ma~ntenance bond must be submitted, or the performance bond replaced with a rnamtenance bond, and !reld for one year. After one year, the, maintenance bo!ld may be released a/1er DOES has completed a seco11d inspection and determined tliat tile tre6 lrnve been kept healthy aml thriving. NOTE: 1. KCC 21,.\.16.050 Landscaping w street frout::iges. 'l!Je average widtli of perimeter landscaping along street frontages shall be proYided as follows: For single-lamily subdi,·isions: a. Trees shall be pla111eJ at the rate of one tree for every 40 feet of '.rontage along a neighborhood collector street or arterial street. b. lhe trees shall be: I. Loc1ted \\·ithin (he str1cet rigl1t-of-way if permitted by t1 1e custodial state or local agency; 2. No more than 20 feet from the street right-of-way line ll"ben locared \\'ithin a lot; 3. Ma_inlaincd by the ::idjacent landowner unlcs~ part ofa County maintenance prngram; and 4. A species appro,·cd by tl1e County if located within the street right-of-way and compatible with o\"edir:.iJ utility lines. c. Tile trees may be spread .it in~·gular intervals in order to ?ccomm:-1date sight dlstance requirements for driYeways and rntcrsec11ons. 2. KCC ZIA. I 6.190 Finnndal guarantees. Flnancial f!uarantees s!Jall be requ1red consistent with 1l1e pro\"is1ons ofT1tle 27A. - Sig1'.ilka11t Tn.'c f\dtution-KCC l. L\.33.:UO 1Ybich upplies to \lie site, a d:.:tailc~ tree rt'lent1on plan :,liatl be submitted with tlw ...:nginecring plans for (he s~1bJect p_Iat. Tli-: Lrcc rete11tioJ1 plan (and engi11c(·ring pltms) shall be cons1stc111_1nth thi: rs:ql1ireme11ts of KCC 21 A.38_230, as we!! as the conceptual trl"C r_e1e11t1_on plan .which i, pmt of the hc:;ring record for thi3 project. No ckarmg of the s_ubJectyrop_erty is pc1111ittcd un(il the final tree retention plan is appro\"e'.l by LUSD. flaggmg and !e1npornry fencing of trees to be retained sholl b~ pro1·idetl, consistent with KCC 2 IA.38.230B4. The pbccment of impcn'1ou~ surfaces, fill mat<'rial, cxca\"iilion work, or the storage of con~truct10It ~rnterial~ is prohibited 1\ithin tho;; fenced areas arol;nd preserl'cd trees, c.\.cept /or gradmg work perniiu...:d pursuant to KCC 21.-\.38.230I34d(2). A n?t<: shall be placed on the Jina! plat indicating tbat th...: trees shown to be r1c1mncd on tlie tree rctentiou pbll shall be maintained by th1c future owners of the proposed lots, consistent wi1h KCC 21A.38.230B6. (Note that the tree retc_ntion pbn ~hall be l!lcludcd ,1s part ol tl1e final engineering plans for the su_bJe_ct pb(.) lf lhe1\' are 110 s1e111licm1t tre~.s as detin,;;.9 __ bv the Sq_~ci.il 0Yerlav D1stnet Dr!.the si(e th~n this recuircment docs 1101 apgJy_,. The existi1!g house shall be rc11101-i.:J or demolished prior to the final apprond a11d m.:onlmg. A demolition permit ~hall be obtained prior to demolition. C. Provide 35' pal"ed radii n! tbe inkrsection of !06'h An:nue SE and SE 172 Street per KCRS Section 2.10. Di..'Uic,lte a 25-fool property line radius at the intersection of 106'1\ Avenue SE and SE l 72"J Stn:ct p...:r KCRS Section 2. l O. 8. !{o::d '.'lli1ig:dion Pa) rn~ot S:, ,tun D. Existing roadside vbs(acle(s) sh:111 be 1·doca1cd 10 p1·0,·ide a mi11lmu111 clearance of 10 feel from th...: edg...: of the tr.m;I Jane 10 the obstacle(s) per KCRS Section 5.11. E. Private access to lo(s 2 and 3 shall be shown as a joint-use drll"c\1·ay tract per KCRS Section 3.01. The tr,;ct shall be cu1 undivideJ ownership to the lots it sen-i.:s, and the lot owners shall be rc~ponsible for its m:1i11tcna1m.:. lhe tract oha!l be 20-feet wide with a 18-fooc-witlc paved SLirfo...:e. The tract shall be a minimum of 20 fo:t in kngth. UTILITY CONFLICT NOTE: CAUTION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE @ 1-800-424-5555 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSING TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE NOT GUARANTEED AND ARE SUBJECT TO VARIATION. LEGAL DESCRIPTION LDT lJ, BLOCK 4, AKER'S FARMS ND, 5, ACCORDING TD THE PLAT THEREOF, RECORDED IN VOLUME 40 OF PLATS, PAGE 27, IN l<ING COUNTY, \./ASHINGTDN1 EXCEPT THE \./EST 170 FT, AS MEASURED ALONG THE NORTH LINE THEREDFJ AND EXCEPT THE NORTH 60 FT. OF THE REMAINDER, 9. IU. The applicant slrnll comply with Road Mitigation Payment System (MPS), by paying the rrquired l'v!PS fee as drtcrmined by King County Department of Transportation, plus an a<lmini,trative fee. The applicant bas an uption to either: A. Pay the \1l'S fee at final short subdivisio11 !'ecording and tlie MPS administrative fee at final sl101t subdivisioll application, or B. Pny tl1e l\fPS fee at b1Jilding permit issuaHce and the MPS administrative fee at the time of bull ding permit applic::ition. If option A is chosen, then the following r1ote shall be shown on the final sl101t plat: !\IPS FEE l\"OTICE; All fees required by King County code 14.75, Mitigation Payment Syskm (MPS) have been paid. If option I3 is cl1osen, then the following mJ!e shall be shown on the final short plat l\lPS FEE .\'OTlCE: This short plat is subject to King County Code No. 14.75, King CouJJty Ro:.id Mitigation Payment Sys(em (,\!PS). Tbt.: MPS fees plus the l\1PS administrative fee shall be paid at 1lie ti1ne of building permit application ut the r:ite in effCct at that time. Stale Em·ironmental Policy Act (SEP...\) This slwrt subdi\·ision was o:crrip( frolll tlle pro\·i~ion of the State En1·ironmcntal Policy Aet (SEJ'A). 0(her Considerations Prelim!!lal)' approval oftliis application docs not limit the applicum's responsibility to obtain any required pcnnit or lic...:nse from tile Swtc or other regulatory body .. This may include obtaining a forest practice permit fro111 the Washington Stale Department of Natural Resources for tree removal. VERTICAL DA TUM, NAD B3, PER \./SDDT GEOGRAPHICAL INFDRMA TIDN REPORT BENCHMARK, CONCRETE MONUMENT IN CASE\.// A BRASS PLUG@ THE INTERSECTION OF SR 515 & SE IBOth ST, ELEVATION = 402,09' P[R \./SDDT GEOGRAPHICAL SERVICES SURVEY MARK REPORT, MONUMENT LD, #2606 AND DESIGNATION #IS 1765, Vici n it y M a p t N Soils Map Notice Required Controctors shall notify operators who maintain underground ut!ltty lines in the area of proposed excavation or blasting at least two business days, but not more than ten working days prior to commencement of excavation or demolition in occordonce with RCW Tille 19. Names and telephone numbers of the operators of underground utility lines fn this project appear below. These numbers shall also be used to serve in an emergency conditions as required. Phone SOOS CREEK WATER & SEWER DIST. (25.3) 6.30-9900 Sanitary Sewer SOOS CREEK WA TEF, & SEWER DIST. (25.3) 630-9900 Water District PUGET SOUND ENERGY ( 425) 454-6363 Gas Company PUGET SOUND ENERGY (253) 395--6915 Power Company Coll Before You Dig DIAL-A-DIG 1-800-424-5555 Notes 1. The Developer is required to notify the Land Use Services Division, Land Use Inspection Section (206) 296-6642, three days prior to the beginning of construction for a preconstruction conference and specifically request inspection before beginning: A. Installing siltation and erosion control measures 8. Clearing and grubbing C. Earthwork D. Installation of any underground utility E. Before placing subbase, base or paving surfaces F. Installation of any forms or placing any concrete 2. A permit must be obtained from the office of the Resident Engineer, Washington State Department of Transportation, before any construction is started on any existing state route. 3. A Hydraulic Project Approval (HPA) Permit must be obtained from the Washington Stole Department of Fisheries prior to any work when required. Bonding Information Restoration Bond Amount $ Performance Bond Amount $ _______ _ Site Plan Approval Approval of these plans is for construction of road and drainage improvements, site drainage & grading and temporary erosion control in unincorporated King County only. These plans do not authorize any other utility approval or improvements proposed in any State right of way. Site plan approval is void if the commercial building permit has not been obtained or renewed within two years of approval. Subdivision plan approval is void if the final plat is not recorded prior to the preliminary plat approval expiration. ASSESSORS NO.: 008700-0280 PRO RATA SHARE ASSESSMENT ANALYSIS (County Use Only) Section Township Range Tox Parcel Number 291 12131 10141 I o 10 I s 17 I o 10 Site Location Is within the _ GREE~J3IVER drainage shed(s) Pro Rota Share Assessment(s) ore: D Required D Not Required from the site due to development Peak Runoff Assessment Rate($ Peak Volume Assessment Rate($ for increased storm water runoff. ) per c,f.s. Jncreoses.(10 year, 2 hour storm) ) per Ac. Ft. Jncreases.(2 year, 2 hour storm) AGREEMENTS, PLAN REFERENCES, PERMITS ETC. (To be completed by Consultant) Preliminary Plot Approval/Permit Issued Date: MARCH 12, 2004 Expiration Date: MARCH 12, 2009 Other Related Permit Numbers Received: _ Right-of-Way Use Permit Grading Building/Structural Other ______________ _ Board feet of tree removal on site: Cubic yards of material hauled on/off the site: Is this a erosion sensitive area site? (Yes/No): NONE ND Nate: If "yes", a Highly Sensitive Site Erosion Control Supervisor is required-See ESC plan and TIR for details. Dote Ernerg enc1:,1 911 Pol ice-Fire-Rescue RECOMMENDED FOR APPROVAL (To be completed by King County) Engineer Plan Reviewer Engineer Supervisor Traffic & Planning Engineer Sensitive Areas Structural Review Engineer Other I APPROVED FOR CONSTRUCTION ~P-ART~N_T OF DEVELOPMENT & ENVIRONMENTAL SERVICES . ® King County, Washington Date Q_ _c ~ L ~ Q) V -C C (I) " " ::, 0 0 J!: 00 '--., ., C a, '--C ow [j,I James H. Sanders, P.E. Development Engineer PROJECT CONTACT INFORMATION ___ H_A_M_I_N_H_C_H_A_U __ __,( 425) 643-3993 Name 4101 150th AVE. SE 98006 BELLEVUE, WA. Address and Zip Code Phone D A Partnership 8l An Individual ___ H_A_M_IN_H_C_H_A_U __ ~C 425) 643-3993 Name 4101 150th AVE. SE 98006 BELLEVUE, WA. Address and Zip Code Phone D A Corporation D A Partnership I& An Individual -=-J=A=E-=-G=E='R'-=Ec:..-N:_::G:.::I::....cN=E=E='R=IN'-'-G-=----'-<-253) 850-0934 Name Phone 9419 S. 204 PL. KENT 98031 Address and Zip Code L C, 0 (/) z > L -(l) a: o__ :J w U) '-.... w L (l) z (l) C - CJ) C, C w z '-.... +-' w 0 (l) +-' L a: 0 w L <{ C, C CJ) w (/) tJ) <{ 0 J 11) CJ "il i:i:: .... I:";) aC1 c::::, ...., 0:) ':j< ~ c::::, ".! . aC1 : ...., :::1 • 0...., C/) ~ O)~ .... ':j< 0) .j- 10 Ol 0 I 0 If) OJ w (L Ci:'. w (.:, w <( --, --, (/) w ::;; <( --, tJ) C 0 _c o_ L 0 +-' 0 C ·-u L 0 0 u _µ 0 tJ) ·~ 0 L o_ [o) [ElerE~W!rE~ lJll APR O 9 2007 K.C. o.o.E.S. ~ .... c::::, c::::, cri I:";) c::::, >-:i L 0 tJ) z _Q E -+-' C w :J :::J (J) _J z z E LL >-, -+-' Q_ -+-' 0 0 U) > tJ) w -~ (J) 0 +-' 0 > 0 L (J) 0 <{ o_ 0 License/Seal Sheet 1 of 3 A PORTION OF THE SW 1/4 OF SECTION 29, TWP. 23 N., AGE. 4 E., W.M. ROFILE @ EXIST 3901-:'~----~-----FJ-~i-NO_R_T_H_P_VM_T_._E_DG1 _ti--j;s-----------jr----t----;==o':-=T2"-TP p--,,.--,,u-,,,,,-------+-'3~9~0--1 0 380 375 370 -.. -- PROFILE @ PROPO ED CURB FLOW LINE ---- ---- ~ET 385 --IE:--380-.+-t-------+-"~~--i 2+66.91, 26.2' LT -b,-=--+-------·------+------_CB ;liL(TYP.~E~~1 ~-t---------- RIM: 388.0 380 --------t--t-----------------··--t--------- 1 +52.39, 21.2' LT CB #2 (TYPE 1) RIM: 380.91 IE: 377.9 -f-------------Hl--------~--1 IE: 385.0 ··-·---------+--------375 370 EX/SS~ RIM=383.0 \ " 1-- <[ _J 10. .._, EX, 12' CCP ~--rNV=381.5 BLOCK 4 AKER 1 S FARMS ND. 5 VOL 40) PAGE 27 LDT 12 FLOW LINE TO BE ~ DIRECTED TO CATCH BASIN AS SHOWN ON PLAN w 20' w z z ::J TRACT ::J f-f- 0 0 _J 18' 1' _J 1' ~ A.C. PAVEMENT 3' ASPHALT WEDGE CURB";--..., I I ii' 2% $.;~V//~"'/;-"'~,"~"~S::'S=s::~==::::=-'1~~-3•:=· ~--~-~-';· ~-~--~•~• 2,.~.~a /~V/~V/0'-''// _J ··· • -· ., oQ 0 0°0°0 "/:.,"•"o•"o''°"o••o;_ 0.5' @ BACK OF ~·-;_;~~~~;""• 00 0 .rn~t7k;--tl~Th~ ~ ~;,!-:S'/1~11 ,¢$ 2" COMPACTED DEPTH WEDGE CLASS "B" ASPHALT 1 1/2" MIN. COMPACTED DEPTH CRUSHED SURFACING TOP COURSE 2 1 /2" MIN. COMPACTED DEPTH CRUSHED SURFACING BASE COURSE I ~L ..... ~ ~: 300.01' (CALC) 300' (PLAT> ADDITIONAL TREATMENT MAY BE REQUIRED DEPENDING ON SOIL CONDITIONS. SEE SEC. 4.02 1+00 390 -0- C r--- _J u 0 0 385 + 0 380 375 370 10+00 SCALE: -· . . . "' ., 1" - 1 " I SE 2+00 172nd ST. 20' HORZ. 5' VERT. (URBAN SUB ACCESS) _ 1 ___ m· 0:: d I u ROFILE @ EXIST n.. I EAST PVMT. EDGE " . N ;';; I PROFILE @ PROPOSED + 0 CURB FLOW LINE - I 4.6% ------. .. -1---- SCALE: 1" 1" - ,-: U>3 ><'-w 0:: VARIES 5' SIDEWALK 0.5' -t& -' , '-'• It I "T ...... .....-I\ I LOI PT OF CURB CB #3 (TYPE 1) RIM 377.1 IE: 375. 5 (EX. 12n) IE: 375.4 (NEW 12") SE OVER EXIST. 12" <D " N (Jl r--CJ) r--r-- "' "' 20' HORZ. 5' VERT. 11+00 106th AVE. . . SE (URBAN SUB ACCESS) 30' n.. 0 w 12· SAW CUT f-z w :::; ~ <( n.. (9-l 3 '-0:: (9-l VARIES VARIES ± 7.5' (106th) i-----~~~7'-----'-1--- 4' (172nd) I' INSIDE EX PVMT. (106th) 4' INSIDE E . PVMT. (17 nd) 2% ui ~ 0 390 <..i 0 z w <D (Jl 385 " ' ~ - -- 380 375 370 "' " -IX) "' ' I g I~ w ;t,-z r--Q ,_, ..... · __ I ~ ~ 3+00 I '§I !i STREET TREE -WESTERN LARCH U ~ (LARIX OCCIDENTALIS) PLAN~ I 1--~ 5' FROM R.O.W. LINE (4 TREES) ~~ ~ LJJ REMOVE ~ EX 1 O" CONC. o: - RET. WALL 12' RCP J INV=369.7 II I · ll;e:pp 11 l •. II ..___-.-_ II ASPHALT D/w APRON II -H pp':e: ·' _I I CONC, I I -·- 130,01' EXTEND NEW ASPHALT TO EXIST. DRIVEWAY ASPHALT EX HOUSE I I I I. ~'(-+ --i;'.' 4" THICK / CONG. WALK 2.0% EXIST/ G PAVEMENT 172nd) EXISTING PAVEMENT 106th) ,,~ n5" /_ 1/4" EDGED 1 GROOVE /"R~ 2.0% B 1· .. · ,, ,· SSMH RIM=376,5 VERTICAL CONC. CURB & GUTTER CROSS SECTION SE 172nd ST. & 106th AVE S (URBAN SUB ACCESS) N.T.S. 2" CLASS "8" ASPHALT CONCRETE 1.5" COMPACTED DEPTH CRUSHED SURFACING TOP COURSE 5" COMPACTED DEPTH CRUSHED SURFACING BASE COUSE ADDITIONAL GRAVEL MAY BE REQUIRED DEPENDING ON SOIL CONDITIONS 50% ,-. • Q .. --.!. ~ 4,, ·.4,,. 44 . T ; ', '; :__L 78" OR 24" I *NOTE: TOP OF CURB @ DRIVEWAYS CEMENT CONCRETE VERTICAL CURB AND GUTTER NOT TO SCALE NOTE: 1. TRACT "A' IS A JOINT USE DRIVEWAY TRACT TO BE JOINTLY OWNED AND MAINTAINED BY LOTS #2 AND #3. 2. EXISTING WATER MAIN SHALL BE LOCATED BY POTHOLING PRIOR TO INSTALLATION OF DRAINAGE SYSTEM. 12' CDNC. RET. \,/ALL \,/ITH \,/DOD FENCE (\,/ALL ON PROP, LN.) GRAPHIC SCALE 10 20 10 I I • ( IN FEET ) 1 inch = 20 ft. ' Cf) (U r LDT 13 r--- 1 I I EX HOUSE I I L--~ TRACT "A" JOINT USE DRIVEWAY TRACT N.T.S. STREET TREE -WESTERN LARCH (LARIX OCCIDENTALIS) PLANTED 5' INSIDE OF R.O. W. LINE ( 4 TREES) 2+66.91, 26.2' LT CB #1 TYPE 1) RIM: 388.0 IE: 385.0 King County Department of Development and Environmental Services APPROVAL FOR SITE CONSTRUCTION Review Engineer ENGRCOMP Date Senior Engineer ENGRCOMP Date BO , DEVELOPMENT ENGINEER APPROVAL Date Comments: ... ------ RE~SIONS: in i:::) (CO) ~ C 0) ~ C <n !:.i g; ~ :;.. "" ·<t: :"Ii (0 ~ :S iii::;;;, C f.i' C\l ~ ~S2~ ... ~~ ~ C,_;i ~~::ti i:i.. ,:.: z < (.) :J ()._ ()._ < DATE: 3/16/07 SCALE: 1" = 30' DESIGN BY: JJJ DRWN. BY: JJJ APP. BY: FILE No. SHEET 2 OF 3 GENERAL NOTES 1. All construction shall be in accordance with the King County Code (KCC), Road Standards (KCRS), and the King County Council's conditions of preliminary subdivision approval. It shall be the sole responsibility of the applicant and the professional civil engineer to correct any error, omission. or variation from the above requirements found in these plans. All corrections shall be at no additional cost or liability to King County. 2. The clcsign elements within these plans have been reviewed according to the King County Department of Development and Environmental Services (DDES) Engineering Review checklist. Some elements may have been overlooked or missed by the DDES plan reviewer. Any variance from adopted standards is not allowed unless specificitlly approved by King County prior to construction. 3. Approval of this road, grading, and drainage plan does not constitute an approval of any other construction (e.g. domestic water conveyance, sewer conveyance, gas, electrical, etc.) 4. Before any construction or development activity, a pre-construction meeting must be held between the DDES's Development Inspection Unit, the Applicant, and the Applicant's Construction Representative. 5. A copy of these approved plans must be on the job site whenever construction is in progress. 6. Construction noise shall be limited as per King County Code (Section 12.88); normally, this is 7 a.m. to 10 p.m. weekdays and 9 a.m. to 1 O p.m. on weekends. 7. It shall be the applicant's/contractor's responsibility to obtain all construction easements necessary before initiating off-site work within the road rights-of-way. a. Franct1ised utilities or other installations that are not shown on these approved plans shall not be constructed unless an approved set of plans that meet all requirements of KCRS Chapter 8 are submitted to the DDES's Development Inspection Unit three days prior to construction. 9. Datum shall be KCAS unless otherwise approved by DDES. 1 o. Groundwater system construction shall be within a right-of-way or appropriate drainage easement, but not underneath the roadway section. All groundwater systems must be constructed in accordance with Section 81 3.02 of the APWA Standard Specifications. 11. All utility trenches shall be back filled and compacted to 95 percent density. 12. All roadway subgrade shall be back filled and compacted to 95 percent density (WSDOT 2-06.3). 13. Open cutting of existing roadways is not allowed unless specifically approved by DDES and noted on these approved plans. Any open cut shall be restored in accordance wrrh KCRS 8.03(8)3. 14. The contractor shall be responsible for providing adequate safeguards, safety devices, protective equipment, flaggers, and any other needed actions to protect the life, health, and safety of the public, and to protect property in connection with tt1e performance of work covered by the contractor. Any work within the traveled right-of-way that may inte,rupt normal traffic flow shall require at least one flagger for each lane of traffic affected. All sections of the WSDOT Standard Specifications 1-07.23 -Traffic Control, shall apply. DRAINAGE NOTES 1. Proof of llability insurance shall be submitted to DOES prior lo the pre-construction meeting (KCC 9.04.100.0). 2. AU pipe and appurtenances shal! be laid on a properly prepared foundation in accordance with WSDOT 7-02.3(1). This r.hall 1nclude leveling and colTlpacting the trench bottom, the top of the foundation material, and any required pipe bedding, lo a uniform grade so that the entire pipe is supported by ,i uniformly dense unyielding base. 3. Steel pipe shall be galvanized and have asphalt treatment #1 or better inside and outside (KCRS 7.03). 4. All drainage structures, such as catch basins and manholes, not located within a traveled roadway or sidewalk, shall have solid Jocking lids. AJI drainage stru<.:tures associated with a permanent retention/detention facility shall have solid locking lids (KCRS 7.05). 5. All catch basin grates shall conform to KCRS drawing numbers 2-013, 2-018, 2-019, or 2-020, which includes the stamping "OUTFALL TO STREAM, DUMP NO POLLUTANTS" and "Property of King County" (KCRS 7.05). I 6. All driveway culverts located within King County right-of-way shall be of sufficient length to provide a minimum 3:1 slope from the edge of the driveway to the bottom of the ditch. Culverts shall have beveled end sections to match the side slope (KCRS 7.03(L), Drawing No.2-001) 7. Rock for ~,osion protection of roadway ditches, where required, must be of sound quarry rock, placed to a depth of i fool, and must meet the following specifications: 4''-8" rock/40%-70% passing; 2"-4" rock/30%-40% passing; and -2'' rock/10%-20% passing. lnstc:llation shall be in accordance with KCRS 7.02(B) drawing number 2-024. 8. Drainage outlets (stub-outs) shall be provided for each individual lot, except for those lots approved for infiltration by King County. Stub-outs shall conform to the following: a) Each outlet shall be suitably located at the lowest elevation on the lot, so as to servlce all future roof downspouts and footing drains, ~riveways, yard drains, and any other surface or subsurface drains necessary to render the lots suitable for their intended use. Each outlet shall have free-flowing, positive drainage to an approved storm water conveyance system or to an approved outfall location. b) Outlets on each lot shall be located with a five-foot-high, 2" x 4" stake marked "storm" or "drain". The stub-out shall extend above surface level, be visible, and be secured to the stake. c) Pipe material shall conform to under drain specifications described in KCRS 7.04 and, if non-metallic, the pipe shall contain wire or other acceptable detection d) Drainage easements are required for drainage systems designed to convey flows through individual lots. e) The applicant/contractor is responsible for coordinating the Joccitions of all stub-out conveyance lines with respect to the utilities (e.g. power, gas, telephone, television). f) All individual stub-outs shall be privately owned and maintained by the tot homeowner. SIDE\./ALK NOTES I RAMP PLAN CROSSVALK <TYP.) / (SEE STD, PLAN H-5c) TYPE !A CEMENT r' -O' MIN. 6' -O' MIN. LANDING RAMP ,, _ O :0 -· .-1 :OL TOP OF ~ 2%4· -'--'-' -~t~:::, ~d ROAD\,'AY CONCRETE J j 7 '"\_ SIDEVALK DETECTABLE \,'ARNING DEPRESSED PATTERN <SEE DETAIL) CURB & GUTTER <SEE NOTE 3) SECTION C/\J 6' -0' MIN. L Avoid plo.clng dro.lno.ge structures, Junction boxes or other obstructions In front of ro.r,p o.ccess o.reo.s, 2. Detecto.ble wo.rning po.t-terns sho.ll be textured using trunco. ted dor,e po. ttern (see de to.ID. 3, Curb o.nd gutter shown, see the Contro.ct Plo.ns for the curb design specified, See Std, Plon F-1 for curb details, 4, The plon views for SlDE\,/ALK RAMP TYPES lB, lC & lD ore provided to define eoch ro.r,p type. See the RAMP DETAIL an this sheet. See Std. Plo.n F-3 for sidewalk joint plo.cer,ent o.nd deto.ils, 5, Ro.r,p slopes sho.ll not be steeper thon 12H•l V, DRIVEWAY CURB CUT NOTES: RIGHT-OF-WAY UNf. SEE SEC. 3.04 K.C.R.S. FOR JOINT REQUIREMENTS. 2. ROLL GUTIER TO MATCH POSITIVE SUPERELEVATION. 3. SEE DRAWING NO. 1-006 FOR CONFIGURATION Of Flll & WALY.WAY BEHIND CURB IF REQUIRED. 4. FOR INTEGRAL POUR CONSTRUCTION, 1/4N EDGED GROOVE MAY REPLACE EXPANSION JOINT AT INTERFACE BETWEEN THE CURB ANO ADJACENT SIDEWALK. 5. SEE SEC. 3.0.3 FOR EXTRUDED CURB ANCHORAGE. RIGHT-OF-WAY LJNE MATCH EXISTING DRIVEWAY GRADE DRIVEWAY CURB CUT SECTION A-A CEMENT CONCRETE DR,YEWAY 5" THICK NOTES: 1. FOR WIDTHS OF SIDEWALK SEE SEC. 3.02. 2. 3. 4. 5. FOR WIDTHS OF PAVEMENT AND SHOULDER SEE SECS. 2.02, 2.03, AND 2.04. SHOULDER SHALL BE SURFACED AS REQUIRED BY SECTIONS 3.07 AND 4.01. IF PAVED, SHOULDER SLOPE SHALL MATCH CROWN SLOPE OR .02 FT./FT. FOR CURB AND SIDEWALK JOINTS SEE DWG. NO. 3-001. TRANSITION RAMP SHALL BE TEXTURED BY IMPRINT OF METAL GRID WITH 1 /2" SPACING. 4" CEMENT CONCRETE SIDEWALK AND RAMP . ,,,I . ' ~ . ·' 6'-o" MIN. 12 SECTION A-A CEMENT TRANSITION CONCRETE SIDEWALK TO ASPHALT SHOULDER ---> L' ---------- EROSION AND SEDIMENTATION CONTROL NOTES 1. Approval of this erosion and sedimentation control (ESC) pion does not constitute on approval of permanent road or drainage design (e.g. size and location of roads, pipes, restrictors, channels, retention facilities, utilities, etc.). 2. The implementation of these ESC plans and the construction, maintenance, replacement, and upgrading of these ESC facilities is the responsibility of the applicant/ESC supervisor until all construction is approved. 3. The boundaries of the clearing limits shown on this plan shall be clearly flagged by a continuous length of survey tape (or fencing, if required) prior to construction. During the construction period, no disturbance beyond the clearing limits shall be permitted. The clearing limits shall be maintained by the applicant/ESC supervisor for the duration of construction. 4. The ESC facilities shown on this plan must be constructed prior to or in conjunction with all clearing and grading so as to ensure that the transport of sediment to surface waters, drainage systems, and adjacent properties is minimized. 5. The ESC facilities shown on this plan are the minimum requirements for anticipated site conditions. construction period, these ESC facilities shall be upgraded as needed for unexpected storm events and account for changing site conditions ( e.g. additional sump pumps, relocation of ditches and silt fences, During the modified to etc.). 6. The ESC facilities shall be inspected daily by the applicant/ESC supervisor and maintained ta ensure continued proper functioning. Written records shall be kept of weekly reviews of the ESC facilities during the wet season (Oct. 1 to April 30) and of monthly reviews during the dry season (May 1 to Sept. 30). 7. Any areas of exposed soils, including roadway embqnkments, that will not be disturbed for two days durin9 _ the season or seven days during the dry season shall be immediately stabilized with the approved ESC methods (e.g., seeding, mulching, plastic covering, etc.). . _ wet 8. Any area needing ESC measures, not requiring immediate attention, shall be addressed within fifteen (15) days. 9. The ESC facilities on inactive sites shall be inspected and maintained a minimum of once a month or within 48 hours following ., storm event. 10. At no time shall more than one (1) foot of sediment be allowed to accumulate within a catch basin. All catch basins and conveyance lines shall be cleaned prior to paving. The cleaning operation shall not flush sediment-laden water into the downstream system. 11. Stabilized construction entrances and roads shall be installed at the beginning of construction and maintained for the duration of the project. Additional measures, such as wash pads, may be required to ensure that all paved areas are kept clean for the duration of the project. 12, Any permanent flow control facility used as a temporary settling basin shall be modified with the necessary erosion control measures and shall provide adequate storage capacity. If the facility is to function ultimately as an infiltration system, the temporary facility must be graded so that the bottom and sides are at least three feet above the final grade of the p<;rmanent facility. 13. 'Mlere straw mulch for temporary erosion control is required, it shall be applied at a minimum thickness of 2 to 3 inches. 14. Prior to the beginning of the wet season (Oct. 1), all disturbed areas shall be reviewed to identify which ones con be seeded in preparation for the winter rains. Disturbed areas shall be seeded within one week of the beginning of the wet season. A sketch mop of those areas to be seeded and those areas to remain uncovered shall be submitted to the DDES inspector. The DDES inspector can require seeding of additional areas in order to protect surface waters, adjacent properties, or drainage facilities. MATCH EXISTING OR PROPOSED SURFACE ASPHALT CONCRETE CONSTRUCTION SEQUENCE 1. Arrange and attend a preconstruction meeting with King County DOES Inspections Unit. Call (206) 296-6642. 2. Flag clearing limits and easements. Flag property lines. 3. Post sign with name and phone number of ESC supervisor. 4. Flag all trees that to be saved. 5. Grade and install quarry spall construction entrance. 6. Install silt fencing as shown on the plans. 7. Maintain erosion control measures in accordance with King County standards and manufacturer's recommendations. 8. Relocate surface water controls or erosion control measures, or install new measures so that as site conditions change the erosion and sediment control is always in accordance with the King County Erosion and Sediment Control Standards. 9. Cover all areas that will be unworked for more than seven days during the dry season or two days during the wet season with straw, wood fiber mulch, compost, plastic sheeting or equivalent. 10. Stabilize all areas within seven days of reaching final grade. 11. Seed. or sod any areas to remain unworked for more than 30 days. 12. Upon completion of the project, stabilize all disturbed areas and remove BMPs upon approval of the Inspector. King County Deportment of Development ond Envfronmentol Services APPROVAL FOR SITE CONSTRUCTION Review Engineer ENGRCOMP Date Senior Engineer ENGRCOMP Date DEVELOPMENT ENGINEER APPROVAL Date Comments: REVISIONS: CJ z -a: 'l) 'I< w (,) (1j I;>';) IC') 0:, IC') w ~;; 0 .... I 0 z ..q 0 0 I IC') 0 -..., c:o co IC') 0 "I< o:i '"" co 0 C\! I;>';) .-., z • IC') I;>';) ..q ~ ~ IC') w ..., ~ ::l ' ~ . a: C..., ~ <I) .:i o:i ~ <I) w 1:1 l>'1 .., 0 <II 0 "I< ~~ o:i w ffi <( ~ "") h ~ ~ ~ i;J ~ Cl) ~ 0~ ~ "<: E-,; ~ (/) :S ~ &-4 ~ C .... ~ ...:i ~ 0 e...; C't':) <'-~ .... ~ ~ "' u 0 w --, 0 "' 0.. I;>';) I:::) (0 0:, ~00:, ~ OJ;>';) tJ ~~~ "<: :oi (0 ~ .q Ii::: IQ' C .. C\l N ~~~ ~ ra:i • '""'""'~ ~ ON ~ ii:l ~ c.; "' z <( 0 :J 0.. 0.. <( DATE: 3/16/07 SCALE: 1'' ~ 30' DESIGN BY: JJJ DR\\N. BY: JJJ APP, BY: FILE No, SHEET 3 OF 3 -i I ----------------------------------------~--- • o';j ---~------------------------------------..Jil.F"--------------------------~-------------------------------------~-------·-----------------·~-----~---------- n:: 0 CL REVISIONS: 1+00 10+00 SCALE: 1" 1'' SCALE: 1" 1 " VARIES 5' 20' 5' 20' 5' HORZ. VERT. HORZ. VERT. 30' ------~-'------ SIDEW,~LK (URBAN SUB ACCESS) N.T.S. 2+00 SE 172nd ST. (URBAN SUB ACCESS) 11+00 106th AVE. SE (URBAN SUB ACCESS) 12' f-z w ::a, ~ <( CL c;J ' A PORTION OF THE SW 1/4 OF SECTION 29, 23 N., RGE. 4 E., W.M. NOTE: PER KCRS SECTION 4.1 OF, A 1 INCH FULL WIDTH OVERLAY '._;HALL BE REQUIRED ALONG THE PROPERTY FRONTAGE OF 106th AVE. SE AND . SE 172nd ST. APPROPRIATE REPAIRS TO THE EXISTING SUBGRADE, BASE MATERIAL, SURFACING AND PRE-LEVEL MAY BE REQUIRED PRIOR TO PLACING THE OVERLAY. THE OVERLAY MAY BE WAIVED ONLY UPON WRITTEN REQUEST AND AFTER AN EVALUATION OF PAVEMENT CONDITIONS AND/OR CHANNELIZATION REQUIREMENTS HAS BEEN COMPLETED BY THE COUNTY ROAD ENGINEER OR DEVELOPMENT ENGINEER. -"' f-- EX / SSMJ,i_"' _5 EX. 12' CCP BLOCK 4 AKER 1 S FARMS \/DL 40) PAGE LOT 12 ND. 5 27 FLOW Lli'IE TO BE / ---DIRECTED TO CATCH BASIN AS SHOWN ON PLAN ~ _ I 20' ~ :J I TRACT ::J § I 1 / 18' I' § THICKENED --1---3' 1 / A.C. PAV~r~E~ii'_____ 1 - EDGE CURB "-, ,----: / I,--',, It 2% -i=---~---_ --s:_ ----.-,_-s_-c._LNl~llly'-1/".;.,V,f 71/~///~///::;,I!/ r,-~ :s=._.-.:::=.-s::=:s:::-cs=--= · __ s... ';___ \_ __ ~ -~~=-=-- T ~; ' ~ :~~;: :_:_ ', 0 ' ~-\\_ ;,;;;;~~h;/;;:J1-{i-~;~;i:~:1;;;.:ii . 1£'7.7;::<:-7/!;J7!7--.? --...: 0.5' ?I) BACK OF~· ., ' \ -2" COMPACTED DEPTH WEDGE CLASS "B'' ASPHALT ' \ 1 1/2" MIN. COMPACTED DEPTH -\ CRUSHED SURFACING TOP COURSE 2 1/2" MIN. COMPACTED DEPTH --CRUSHED SURFACING BASE COURSE RIM=383.0 "' fl, /TINV=381.5 , 1w I ~r 1 ~ L +h /81:J 111-r 300.01' (CALC) 300' (PLAT) \_ ADDITIONAL TREATMENT MAY BE REQUIRED DEPENDING ON SOIL CONDITIONS. SEE SEC. L,j -I co 1'RACrf n A,, 130.01' 4.02 3+00 2S ~ l~-1 11.1 <I) /\ nt1 1~ 11'.Q:ip JOINJ_lL$E DRIVE\ALAY TRACT t--1.T.S. ' STREET TREE (TYP) -WESTERN LARCH (LARIX OCCIDENTALIS) PLANTED~'-., 5' FROM R.0. W. LINE ( 4 TREES) · \ w w 11 (· I ~I ~ I 1":, 12' CDNC. RET. 13 ot II -..j__ '&\ 1 EXTEND NEW ASPHALT TO \./ALL \./ITH I 1.11 1 ---y \./DOD FENCE ~ g A"'P!/'A' T 1 \ /---,- 1 --EXIST. DRIVEWA ASP~ALT r(\./ALL ON PROP. LN.l -I w W\ -" n ·'-EX' ONC. EX HOUSE --·- --1 2· J_ -----., ::e: 1 u • D/w APRON 1 1 ;/ . ~ "'---J ~I -J \ II I, \I 20' LONG DISPERSAL TRENCH I -, / ,: r-----____ <rf rl , _ -rFOR RQOF DOWNSPOUT DRAINAGE / I ; REMOVE d::f .,., -I I --------, ---1 / 1 =1· \_ 2" ASPHALT CONC PAVEMENT '\ T EX 10" CONG./ 1--Qf. /I \ l\ , \ \ / /; / RET. WALL--~:1~~r-"' ,~I ~--r--· -~ _ 1 S88'\1_:_~~E 130,0~'_,__~ SIDEWALK TRANSITION RAMP~-/ x:r 1f • I~ J__ --r _,!9 ·~2 j_ ,:: __ ~-3 r f--------/50~20'~---.i 11 +49.6 PROP LINE __.--/ -I ----k 111 1 1 1 Ex GRA tEL----n-;-~-1 1 . END CURB, GUTTER & SIDEWALK II I if---~Lft ,j----1---_;_ DRIVE .! 1111 CAR-I I I : 1n1-I s.11 I • , , • I PORT 1 1 -I' 112· ' '1 <'1!'1_b-I ' i';; ,--;_JI I I PROP051.D 8 1 11 1 ~!'\ --~ E STDTREES , ' \ I ----_J I \ - CONTOUll<S--~ +--I~ 3T0_'__3' .1_ ~ TO RtMAIN T! OT__ ¥J 0 3~ CT' LQTI # _l-• ~ _ /"-H/ 11. 0 ,,1 \~ K-m o; 1 ,1, 0 , :Jao ,:::i, I ' I -f'.=\ \ -,, \-r~/ (') I '1' 5 ~72+ s . \ 0 I -----I §,;, 1 /1 \ ,-ii VJ 1Y 4 190+ SQ Pf ! lfl ,::J -l' Q, FT. I -· I -,_ ::;::I , I <l6 '\1 \-' 1 ' -• I ' 1 1 -- 1 'N en: , 1 I __!>v , -~ 20· \ {A(/_ . ., I EXrH.PUSE --1 ---.. I ' 1g I g 1-:/, . I (: ~ -i I ,;t-rtt Pcr1~1[1so / I i (REMOVE> 11 I Ex HousE •:,: -' T ,.:-\0. ~ TRAGT "A" -. . -/ I ' I I REMOVE EXIST. MA11soxEs 1';; / ~: i;ll II · ('.'\ \----zJ.u.d T. J ;=> \ \ ~1 5 9 ,88 , 1 -i , 1 it: 1 &INSTALLNDCBU COORD-~ ~~ /II 11< •. ;> · ~ ~:1/i: , -, a, I 0 ; L W/ POSTMAN) "-3--------~ II _ _t~o,~ l')N_E~ I --. 9----._JJJ_'. AS~H. c,)0 i ~ i 12 s, ? ----, -[_] .___ o,L:i --WIDTH O , :::: I --, 10+46.1, 14.55__R_r __ ~ --• •,J_ ';-,ell t:J '' ' I • .?{ 21D' --10T_\.t.L 8 I I ~ LOW PT OF CURB ---------------v·, co "--', q_ I [ , , , 1 -, --, '>31+ .ttQ E_I __ J , ---_ ~ N CB #3 (TYfJE 1) ZJ_ EJ v1_ Jl--/111 \ _ /J -'° ·= \ ~--I --.. "'1-" -~ , ~ _ -,-------" I (\J STREET rREE WE.,TER LA_RCH RIM: 377.1 \ I 8 ;"ITT"'. :r 1 I/ :--0': --------------------____ 20_' LONG D1Sf::EF,SAL TRtNCH -----:" ~RIX OCCIDENTALIS) PLANkD IE: 375.5 (EX. 12") ~ \ a "/ / / \1 r,;.J: ~le--EXIST'. TREES FOR ROOF·DS'lliiSPOUT 1R~l_l'!AGE ~-• R ~ 8 / o INSIDE OF R.0.W. LINE (4 rREES) IE: 375.4 (NEW 12") 1,' ~w :I I I/ 11 <~\' \' .,To REMAIN \ <w -0 I -; I w rf~v~~85.i (/) / EX ELEC. PD'dER POLE - SET OVER EXIST. 12'' ~ ~ 16+~J.2~/, ·. f ~t;( -'25' RAD TO BE DEDICATED ' ~ l l I I (REMOVD /(TD BE RELOCATED BY PSE (PER 1993 KCRS) I l Pc '/ -r 111 1 :-1._ \ r--'-- EXIST. CB 14·-12" 9u_c;_T,_____ ---.:,_i"--i :;,'Y .' '~-r: c:\._ --\ ' \ Lnj 6" PVC LOT QB!µN -------;;ASPH. APRON EX 12' RCP IRON @ 1.{1-3% -. -' IJ ,'l 11 $((;DOUBLE HCP RAMP\ -----I STUB (TYP) -----I EX 12' RCP /i-RIM=377.3 -------._ -: I"-i , ·( , '\ , ------------w ', _ • INV=390.3 JNV=375 2 N 18' RCP <EX> REMOVE\ 't ', 'I c. 1 [_RELOCATED F.H. ' -f)RrYEWAY __ , EX. 12" t , \ / ·-. /[ INV=386 7 (REMOVE) INV=37s:2 E: 12' RCP cEx> ,REMCJVE>-,._ f-:1 1---~\--..,? ' \~ 'i: _ NE\./ ELEc.'P.._O\./E ,;_'.":,CURB DROP \ CREMOVD\ ,_ W<-1 //1cj0 __ 12" INLE r IE: 31_7.2 INV~375.1 s.1./. 12· RCP (EX~ • r·---\[)L 1 \., 1 1 ° \{OLE ~~"' <BY P~D , ___ Jtt __ \ 50 _30 ~ _ ..,.,.,~ // 1 __ 1------/"W/_ RIP ~AP _1c_ = _ IE• 3752 (12' D NE\./ \ , s:---i----._\, _I '1 ~~ , ---..., ' / _..,,.,, . 53,3~ "-'="~ -=----, -_ -, . _ ~-\_ l_:_ ~ -_ %t~~-~rcc:_H ___ C~- IE1 375.2 (12' N) NE\./ :g:]P / ·, 1 1 '-' _0\ --f~: ____ ,e /_." _ > _-----~:::::-______ -c-~~--=---_ J_~~JQ __ :~~~=-~j '_ T~-\-E1JGE OF P'AVEMENT ADD SOLID, LOCKING LID I/ \ f IW. V , _ _ _____ -~ -:f:_:_, 0 ----~-~=-I-___ • _________ -\_; ___ SAWCUT 1 1,}, ~ \ , _____ ___ 1 I f:'· )ff; .fl:<-__ --12.:i="lZ:--CE'<t' --• 100 CUF,B/ " o \ ---------, EX ELEC; PD\./E_R POL.E~-----1~ L35'-RAD ____ --~-;/---------f@ 6.22% )?,I /3~AD._ ~-1. _ -t~Ji-}~c:t 1 ~ 1 ,---..,_ s·-12" CP~P @ 27.3% THIC!(f}1/£-0 FOGF ASPI-IAL T DETAIL !'/OT 70 SCALE LDT 1] r-- BY PSE /<PER 1993 Kc 1 s> _ --,--_ -~-r _\____ng;-1 11PR0P0SED \' E l ___ , -__ . ___ . CD'~'-_\=---:-___ 1 __ -----co-_-::--____ 1 _______ _ ' w~ '1 I ~ 1CONTOURS ~ • ::.'-----' , , ____ co-,---., \-_::!) I I tL i.o l ~ f , --. ~-01 , ---1 · OENTERLlt[E ROW , 1 -\ __ ~ -1,, / --=---------cc: ---;_;, N __ '1---_ _ ____ ,c<hD8 t::,'------,-o ,_ ----,---i;-\ ~-2 eos_:--~r -:: _ _:-------::-_----------l,f' -T -C:3gO ~;-----1/! --I. OU I M(NT -------\ ' / 1----=,---I .. -:__ ----' 'T ', L ; ,V (~GE _m:___P~ '\;----,_i:;_xrsTINCI, FIRE'l;jYDRANT __ ---~ ... ;;:::::---;,:;:;;-~· . ,,; I \ \_}j}6_, 26.5' LT /, ! -------_c---,-TO BE Rt'(_OCATEJL~-c:::_-y--/ ----;,~1 -' \ I -CB #1 (TYPE 1) ., _ __ -;/-: --\ <BY CDNTF)~TOR) --;? __ -o;.>:' /_CURB PC CURB PC \ F<IM: 388.56 "/-1--/ __ \ ">-"':.::-~------------;;""'/ -T+18.74 2+23.59 I IE: 385.56 ,f _r_~~--PP,$o --_ --/ ;{crl ;!~ / '\-}•'" II \_ SIDEWALK TRANSITION RAMP II I '---_><_ Sj,_;-----'G 1+52.39 21.2' LT (DETAIL SHT. 3) 12' RCP / ·-. ',_ , -J _ -n'o -, ' I 2+62.28 JNV=369.7 ',_ '-, -------------__...c:'." ° CB #~ (TYPE 1) -END CURB, GUTTER & SIDEWALK ,_;,, -, -0 RIM: 380.91 / . --/ ._?_>__----,;\ 0 IE: 377.9 () - L_'.>SMH RIM=376.5 /" 1115 .. I-1/4" EDGED -GROOVE /"R~ 2 0% • 1 "* f i • . . 7 ' . ' - King County c-1 ,-.\ ~ 0 ..... lTi g /~ 33 . 0 2; k:i N &-: v:i ~ . q . q 6" I 50% 0 ~- Oeportrnent of Development and Environmental Services F-~APPROVAL FO! SITE CONSTRUCrl_O_N __ __, NOTE: ,, .. , I ' . . 18" . .. . ' ' E 1. TRACT "A' IS A JOINT USE DRIVEWAY TRACT TO BE JOINTLY OWNED AND MAINTAINED BY LOTS #2 AND #3. F/eview Engineer ENGRCOMP Date *NOTE: TOP OF CURB @ DRIVEWAYS 2. EXISTING WATER MAIN SHALL BE LOCATED BY POTHOLING PRIOR TO INSTALLATION OF DRAINAGE SYSTEM. GRAPHIC SCALE CEMENT CONCRETE VERTICAL CURB AND GUTTER NOT TO SCALE ( lN FEET ) inch = 20 ft. Senior Engineer DEVELOPMENT ENGINEER Comments: ENGRCOMP Date APPROVAL Date -----------~----__ ___J I. F,EV. PER CTY. ;OMMEN TS 10-1-07 0 z er <l) w (.) -,~ (\j ,,, \Q w 0, \Q -.. "'< 0 '""'-; o, I;') I c:, z 0 <:':I I :S co :g ;g - 0 "/< Cr) <o C) -----C'Ci t') ----z -• tr; C') -Cl ,:'."i ~ l() ;,;: Cll w ..., ---!::l • ci . o....,;;;:;o V) >:I :;,,., er <l) <I.) ' 0-, ~ '1 ;.: w --. 0 ~ ,Cl k; 'sl< i:t. 0 Ol w c::3\-':, h ~ 0... t·"'4 ~ 3 ~ r'l-, (.:) E<i ~ b:: ,_;,. ~i: •,: a Cl) r,- ,t; "' ,;.J 8 E-. <o Q ~ 0 -, "'-4 '1< kl ,,, t, Q ·<r: C":) t-0 ,... "~ ~ Cl.; ~ ~ "' G () w , 0 "' [L <;'J b "1 <o 0, ~ c,, g ~ • o:, I f::! et, C') u ~ ""-ii ~ ·"0 ;:~ ~H "" _...._,_ ~ .q '" ,µ "C-.l ~ 0 k1 ·,qt N l'J :::i ._,, ~ .... s. t -, k1 ci '-'< 2: ~ c::, '-'< ' :;: '" . i:q i:1.1 i:t. "' z < () ::J a. [L < DATE: __]_,11_§ Io 7 ---- SCALE: 1" ---30' DESIGN BY; ____,J_,l_J_ DRWN. BY: JJJ APP. BY; FILE No. SHEET OF _2_ 5 '-------------------------------------------------------------------------------------------------------------------·----------------.-J------...1 ,-------~----------------------~-----------------------,~-----------,--------------------.-------,·-----------,---------. CONDITIONS OF APPROVAL ® King Cuunty Department of Development and Erwirunmental S\1rviGes 9cl0 OclkesUale Avenue SW Renton, WA 98055-1219 COND1TIO:'\S O.F APPROVAL File ?-Jo. File Nau1e: LOJS0016 Chau Short Pbt May 2, 2003 January 30, 2004 Application Oat..:: RevisioH Date: This sl101 ! subdidsion is granted preliminary appro\'al subject to the following Conditions of Appronil. Tbese conditions arc based on a fi..;ld visit nnd current infornrntion the ,1pplicant bas pro,·ided about the shor1 subdivision prup,my. Occasionally, in satisfying the ConcEtiuns of Apprnl'a!, a more definitive land use limitation of the property may be n:vc,1kd. New i11formation (sL1eh ns final Jlealth approval ur srnsiti\·e arec1s rc\·icw) m.iy require addi(ional conditions and may recltKe the number of lots. Pinal appro\·al will be grn11ted afco;r eomplimie.: ll'ith the Conditions of Appnffal. Key codes and gui<.klincs have been nu1ed to provide guid:rncc in preparing tile rcquin~d pbns a11d 01her documents. Compliam·e with some of the fo!IO\\·ing conditions v,·Jll require that cnglnc,;ring plans be 11reparcd by a profrssion,11 ci\'il engineer licensed in the State or Washington. I. 2. 3. Ti!lc 19.-\. A. u. C JJ. The sl1011 subdi\'i:;io11 shall comply with :ill proYisions ofTitk: 19,\. Thi.: final reYkw process must be cornpli:tcd prior to recording of the shon subdivision. The Department of D..:n.: lopment mid En\·ironmental Sen·iccs (ODES) strongly recomm..:nds the f_in:11 Short Plat b_e submitted <!l least one vear prior to 1!1e c:-:,..1Jirillion date of the J)!1.l~. The Final Short Plat subrn11tal package include~: 1. A sur,eyed map page (four 5ets) in<.:luding lot area closure ca!culaiions; 2. Fina! health ,ipprov,il from the King County Jk:1lth Department (diffrrcnt from preli1ni11ary health approv,11 l: 3. A current short plc.t ccrtificak and supporting docrnn..:nts (easements. etc.); 4. Payment of the Final Short Plat submillal fre; 5. A copy of this letkr (preliminary approval lettoer). A licensctl land sun·eyor shall be hin~d to prepare tl1c lln,d short sl1bdi\ islon <lon1menb. These documents shall comply with cill of the following rnnditions for iinal appro\·al: ~II pcrso'.1s havi11g an o~v1~crsl1ip inter1;st in the subjc,·t prope11y urc required to s1g11 the tm.il short subd1nsion. lfrnodilic.itions to the approved prdimina1·y site phrn (Attaclmwnt J) are nenJe~ to ucc.omplish engmeerlng design or fol.!! short pbt, then a revised P.rd1m1~.iry s'.te plan shall be submitted lo DDES for re\'iew and appro\·tll. I he revised site plans ~hall be sulm1ilkd wi1)1 Lhe cngincerin!! pl.ins or the final shon plat subminal. - Surface Water :\Ianagcmeut (KCC 9) J998 King County Surface Wukr Design )!:lnual (S\VD:\I) A fj. This shor~.sLibdivision pr?J~o.5al is subject to Pull Draiuage Rc\'iew p,;r sect.ion -- !. I :2-3. hnal. s'.1ort subd1Y1siori approval sha!I require ful 1 compliance with dramage prov1s1ons and stonn drainage requirements of this sec(ion. Compliance may result in rducing the nu1nber and/or location of lots sliown on the approved prelirnirmry shun subdiYi~ion. The conditions OLHlined below are site-sp..:cific drninage cOOC!itions: - (1) Core Requirement #1-Discharge m 11l1; ;-.:atura! Location (2) Core Requirement #2 -Off-Site Analysis (J) Core Requirement #3 -Flow Coulrnl (-l-) Core Requirement #-l--Con,·cyanc..: System (5) Coce J<,q.,imncnl #5 -Erosirn, & Scdin1c,n,,,ion Contcol (6) Core Requirement%-l\laintenann: ::11J Opc1·~1tiot1 (7) Core Hl•quircm,·nt #7 -fin:u;cial CiLw;;r;te1;s & Liabii:ry (8) Core Requin•mt•n! #8-\Vatcr Qtrnli(y {SJ) Spccinl Requirement #1 -Other Adopted R.:quin.::nw1Hs Ayrofe~siona! ci,·il ~nginccr lic·cnsetl in the St:l1c oi'\\'ashington shall prepare a( l( c:!~~1cal lnforma_lwn Rcp~rt and/or engrncrnng plans per Chapter 2, of the I Y)S Krng County Sui fot1c 'l\':uer fk,1gn J\fanu:il. Jfculth (h'.CC 13) Thi~ proje:t !s exempt from funbcr King County !Teath Department review. EO\\ cvcr, if rmpron:mcnts arc required from ;be Se11·cr and/or the Water ~ist1·icl, then Yerificmion shall be required from said District(s) chat the improvements have lie,·n bonded andlor inslalkd, prior to fin,11 recording of the shon plut. 4. Road Standards (KCC 14) 1993 King County Road Staudurtls, Ordiu:rnce 11187 Final short subdivision approrn! shclll requirr.: full cumpliance with the provisions set fonl1 in tile King County Road Siandards lncludi11g englm:aing plans for all road impro\'cmcnts. The engin..:eri11g plans shall bi: pr1cp,Lred by a professional ci\'i] engiJH.:er liecnsed in the State of Washington. DOES strongly recommends the Ern:>:ineerirw Plans bi.: submitted at le:1st two vears prior !o the exRiration date of the project. A. That portion of the North lia!f of SE ! 72''J Street adjoining the subject prop1;rty sl121ll be improved tu au urban Sub-access st,Lndard per KCRS Section J .03. B. That po~io11 of the East h;ilf of I 06:h A\'enue SE adjolning the subject property shall be unproved 10 an urb:m Sub-access standard per KCRS Scc(ion J .03. 5. G. 7. C. D. F G. H. The folki1\·i11~ 110 1. · J 11 · . ·I , ~ ~:, \ 1,, t1s::. l0\1J1 ,)11 ll1c fr:nl recuhkd ~11ort subdi1·ision: 1) 2) All utiliticc; witnin l'"J)OS"J r·,,1 •· 1• .. .· 111 . . ... !CCC l,~-0 -\\ .i •. l' >il:l )'.: mdmkd WH',;,,, ,;._,,,.·11·,." apDrol'cd b · ti • K-· , · '' '' ·· ·~ J-. • . J 1<.: mg Comi,.y Council pnor to final shoi't subdi\'i~ioJJ rccorclrng, -· All restrictions, casements, tracts, and their purpose shall be shown on the final recorded sho11 subdivision. Building :rnd Construction Standanh (Title 16) Gradi11g. The ilpplic:mt shall cump!y \\ iLh a!I ;1pplicable pro1·isiuns of KCC J 6.82. fire Colle (KCC 17) SL'ction 902 of the 1997 Edition of L'niform Fire Cotlc Tile applicant shall ob1ain tile :1pp:-01·,d of the King Cou11ty Fire Protection Engineer for the adequacy of the fire hy<lr,ml, '>I :dcr m:1i11, and fir1; /kn\ stam!:Lrds of KCC J 7.08 prior to r<:codiug of the Jots. Zouing Code (KCC 2J..I..) A. Density and Uin1cmiom (KCC 2 l .. \.12) All lots sldl m"et the density .:11J dimensions requirements uf the R-S-SO zone classifiea1io11 or shall be as sho\Yn on tbe face of the appro\·ed prelimi- nary sho11 subdi1 is ion, 11 hkh1;1 l'r is largn. /\linor rc\·isions to the slwrt subdivision, which do not 1·1:~ult in substc111tial chanc..:s ,uH.Lior do not create additional 1Dls 111:iy be appro\·ed at the disrn;tion o(LL'SD. 13. StreetTrces(Kl'C21:\.16) Street trec:s sb:.!IJ b,: 1mwideJ alon!! that lJOl"llO!l of'tilc: rie._.'b!-Of'.·W.l)' for lh -. • 106 A\·r.:mw S011thL·i1st :rnd Southeast 172'"1 Strc<:t :1bwti11g 1l1e subject property, pur~uam ,_o the pro\·hons of KCC 2 I A.16 O~U(E) :111d KCC 2 l ,\.16.190, unkss nis1i11g trees :;re shown to be eq 1.1i\'aler:t to the rcquircment ofl'udc. Sc,; note below. The required street trees shall be designed as w luc:itio11 and ~p,1cing mi the lina! pl:m sub1nitt:i!. The street trees m1.1sl be insrnlbl aiid i11spcet1cd, 01 a pct form a nee bo11d pustecl, prior to recording of tile pbL ]fa performanl'I: bond is posted. ihe str,;et trees must be installed :md insp•:c:oetl witl1in one yi:,ir of recording uf 1he plat. At the time of insfection, if tho: trees a1·e found lO be installed per the arproved plan, a ma~ntemmce bo111J must be submitted, or tlie perforlll:mce baud replc!ced with a lll:unt<:nance bo111J, :me! held for u11e y1car. After unc year, the main(r.:11:mc<: bond may be rckc1sed after DDES Jrns completed a second inspeciion and detenmncd that 1he trees haw been kept healthy and thriving. ;\OTE: L KCC 2LUG.050 LarHbc.ipiug-street frontagc.s. The average width ofperims;ter landsc~ping ::!011g street frnntag,:s shill! be provide/as follows: ____.- ·---------------·-•a .. -·- For single-family subdi\·isions: a. 'J_·rees shall be planted at lb!! rate of one tree for C\'CI)' 40 feet of lron(age along a w:igi1borhood collector str~sel or c1neri3] stn:i:L b. The trees shall be: 1 Loca17.d within the: slreo;t right-or-\\'.t)' if pennittcd by the cu~tOlllal state m local agencv· 2. No more than 20 feet from 11;,;' w..:et right-of-way line when located within a Jot· 3. Maintai1ied by the ;djm:ent landowner unless part of a County rnamter1ance program; and 4. ·~ sped.cs approved by the County if located within the street right-of.way and compatible \\'ith ovcrhc:.id utility Jines. c. The trees m:iy be spread al irregular iuten·als in order to '.lc.comm?d11te sight distaJ1ee requirc1nents for Jri\'eways anti llllerSCC!l0l1S. 2. ~{CC 21:\.16.190 finand:ll gu:ir.11drcs. Finaneiccl l!uarnnlees sl1al! be rl'gu1ro;d eonsist<.:nt with the pro\ isions of Title 27A. ~ SigJ'.irirnnt Tree [Zekutio11-KCC 11A.3S.230 wbich ,,pplies to the ~ite, a <l··rniJ,,J trl'e r1;1 ·wion l I ·11 '· · b · d · I ~' ~. ~. '. pans 1,, ve su mnte 1n11 tho; ~'nginc1:ring plans for the s:1.bJcct plat l he tn:e ri:lention phm (and enginnTing plans) sh:111 be c~,r:::i'.o.t~nt .111lh the re(!L:ir~mei:ts o:· KCC 2 ~A.3S.130, :is 11 ,·ll as the conceptu:il \Jee I_dU1t1,111 plan .which 1~ ;1a1t.ot the h..:anng r<:eorJ for 1liis µrnject. No ~knrn:~ or 1,h,; s.ubJeet _PfOP?1Y 1s permitted until tl_ic Jir:a! t1\:e rctcntion plan ls d!lJlfO> "'ci b) ~ L,SD. f lagg:111g :md temporary J~·w.; mg of 11 ces to be ret1ini:d ~~1al_l, b~ pr~1-1de.d· con_:istrnt w_ir.h KCC 2 l.A.3S.~3(1B~. ·1 he placement of 11,1pu\10:h su1J.1l'e::i. J1ll mm,·1ul, exca\·a11on 1York, or the stoi:we or construct;o1i 1;1atcrials is prohibitL·d within Lile frnccd :1r..:as aro:iid presernd trees, except Ill!' gr:1drng \I ork pcirnitkd pur~u:rnt tu K CC 2 ! A .3S.23013,1J(::'. ), A n?te shall b..: pl:l.:cd on .the tio,d plat indiec11i:1g tL!t the tree:; shcnrn to be rt:taim·d on tile t1·ee r,·te11t1uu pl:rn sil:dl bc m:;int;,i1:;·d by tl1e foturi: o1\·n::rs of the pr?pos,,:d lots. -:ons.i:;tem wi:!1 KCC 2lA.3'.L~3(1I36. (Note that tbe tn.'<: rete.nt1on pl:111 ~Ii.di bc u1cluded :is pm of the 1111:il l'11gincering plans for tile su_~J~.ct plat.) I/ tlw1·~· nre no.~g1l1!il·:l!1t trees a~ Jl'tir1,·J_ Qy tile Spe_~·_i_;!l O\erlav D1st11ct on tllt.' -.SJ:~· lh\'Jh.1!.u.s __ r_r:_q\!jrl'<!J.<;.nLdo1cs 1w1 _ _;_,p;··lJ'.:. :·~ie ~-~,ist_ii~g '.'lllb~ _~hall. ~c: 1Tmo1 ::d ur d:mu!i~i1.cd Jlrio.r to the Jin al :ippro,·al <1r,Ll lt:lOidmg. A u ... llwlit1on penrnl ~hall oe obt:11ncJ pnor to d..:molition. C. Pro\'idi.: 35' pa\'ed radii at the intersection of lOC'' An~nuc SE and SE 172 Stre1;t per KCRS Section 2.10. Do;dicate a 25-foot propmy !i11,; r,1diu, ,Lt tl1c intcrse1ction of I 06 1'' A \'cmie SE and SE 172'-j Street per KCRS Section 2. l O. 8. l{o,1 d .\ Ii t lgatio 11 J';1,1 me u t S~ stem D. Existing roadside ob.swd:(s) :::hall be rcloca:,·d to pro\'ide a mir1illlt1Ill clearance of 10 fc<.:t J'rorn the L'dgc of the mn'd lane to the obsrnclc(s) per KCRS S<.'ction 5.11. E. Pri\'ate access to Lots 2 and 3 shall be sh011·n t(S a joint-us<: dt·ivc"Way trnct p<.:r KCRS Section 3.01. The tract sldl be an u11divided Q\1·nersbip to 1!Je !ots it se1·vcs, and the lot owners sliall be responsil,le for its maint<:nanee. Th1; tract shall be 20-fect wide with a !S-fout-\1·ide p:!1·ed surface. The tract slia!l be :t minimum of20 fret in kngth. UTILITY CONFLICT NOTE: CAUTION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOl'YN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE @ 1-800-424-5555 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSING TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE NOT GUARANTEED AND ARE SUBJECT TO VARIATION. LEGAL DESCRIPTION LOT 13, BLOCK 4, AKER'S FARMS NO, 5, ACCORDING TD THE PLAT THEREOF, RECORDED IN VOLUME 40 OF PLATS PAGE 27, IN KING COUNTY, \,/ASHINGTON, ' EXCEPT THE \,/EST 170 FT, AS MEASURED ALONG THE NURTH LINE THEREOF J A~ID EXCEPT THE NORTH 60 FT, OF THE REMAINDER, 9. 10. The applicant sl1all comply 1rith Road ;\litigation P:1ymrnt System (/\!PS), by paying the requi1·ed /\lPS fee as dcterr11im:d by Ki11g County Depai1inent of'Transpo11.:ition, plus an 11dmir1islrntive fre. Tile 11pplicant h:1s an option to either: A. Pay the MPS fee at final short sublli1·ision recording and the 1\IPS admini5trntive fee al tina! short suli,hisio11 applicmion, or D. P;iy the !vll'S fre at building pem1il issuance ·and the MPS administrative ke al the tlme ofbu1lding permit applic;111on. If option A is chosen, tlicn the folloll'ing nok sh..!ll b,.; shown on the fin.ii short plat: .\[PS FEE :\OTICE: All frcs required by King County cud1; 14.75, tvlitigc1tion Payment System (i'v!PS) ll<l\ e bcrn p:1id. If option B is chosen, ihen the fo!lJ1\'lng note shal! be shown on tlie final short plat: ;\!I'S FEE ;,;onu:: This short pl:it is subject to King l'ounty.Co<le i\o. 14.75, King Cotmly R0c1d l\'litig:1tion P:1ym,:11t System (:\ll'S). The \IFS fees plus tli1; ;\·JPS :1dministrntl\·e k•e:: ~hall be p:1id al tb<: lime ofbuildirig pnlllit application at the rate in cff..:ct at th:1t time. Slate [111·irorunc11tal Policy ,\ct lSEl',\I Tliis short subJi\·ision \\'~b ~':<:ernpt from tli,· pro\·ision ofthc St:1tc En•;ironmcn!al Policy Act (SEJJA). Other Consicll·ra(ions Prtliminary api'rO\a] oftl1is app]icaiion dll\~S noc limit lh~ applicant's responsibility tu obtain auy requi1·ed permit or license fro111 the State or other regulatory body .. This may include obtai1;ing a forest prnctice pmnit from tile Washington State Department ofi\otural Resou1'Ces for tree remoYal. CD\JER l)Rf\1"'1/¥£. 1 \:Zof\b PL/'\N NOTE'S 't DET/1. i LS TE sc,p TREE. PLAl'--l j 2 5 + 5 NOTE..: U.S. P.S. i\P?RO\JA<L oF fl\P,\U?oy U::C..~TIDW 0~ f ll.E.. A.T /<ING C.OuN"rt PDEs VERTICAL DA TUM, NAD 83, PER w'SDOT GEOGRAPHICAL INFORMATION REPORT BENCHMARK, CONCRETE MONUMENT IN CASE w'/ A BRASS PLUG@ THE INTERSECTION OF SR 515 8. SE 180th ST, ELEVATION ; 402,09' PER w'SDOT GEOGRAPHICAL SERVICES SURVEY MARK REP[IRT, MONUMENT LD, 112606 AND DESIGNA TIDN ll!S J 765, Vici n it y M op 3' (/) : SW _J3?D. ~I. >-: u.J I _, ;. ' -·------~ <I ~ I ST ·, --·---·-· ~ ."; 5 ,'S ; SW Soils Mop t N Notice Required Contractors shall notify operators who maintain underground utility lines in the area of proposed excavation or blasting at leu::;t two business days, but not more than ten working days prior to commencement of excavation or demolition in accordance with RCW Title 19. Names and telephone numbers of the operators of underground utility lines in this project appear below. These numbers shall also be used to serve in an emergency conditions as required. Phone SOOS CREEK WATER & SEWER DIST. (25,3) 630-9900 Sanitary Sewer SOOS CREEK WATER & SEWER DIST. (253) 630-9900 Water District PUGET SOUND ENERGY ( 425) '154-6363 Gas Company PUGET SOUND ENERGY (253) 395-6915 Power Company Ca!l Before You Dig DIAL-A-DIG 1-800-424-5555 Notes i. The Developer is required to notify the Land Use Services Division, Land Use Inspection Section (206) 296-6642. three days prior to the beginning of construction for a preconstruction conference and specifically request inspection before beginning; A. Installing siltation and erosion control measures B, Clearing and grubbing C. Earth work D. Installation of any underground utility E. Before placing subbase, base or paving surfaces F. Installation of any forms or placing any concrete 2. A permit must be obtained from the office of the Resident Engineer, Washington State Department of Transportation, before any construction is started on any existing state route, 3. A Hydraullc Project Approval (HPA) Permit must be obtained from the Washington State Deportment of Fisheries prior to any work when required. -----··-----·------------------·---·------------- Bonding Information Restoration Bond Amount $ -------- Performance Bond Amount $ _______ _ Site Pion Approval Approval of these plans is for construction of road and drainage improvements, site drainage & grading and temporary erosion control in unincorporated King County only. These plans do no\ authorize any other utility approval or improvements proposed in any State right of way. Site plan approval is vo:a if the commercial building permit has not been obtained or renewed within two years of approval. Subdivision plan approval is void if the final plat is not recorded prior to the preliminary plot approval expiration. ASSESSOR'S' NO.: 008700-0280 PRO RATA SHARE ASSESSMENT ANALYSIS (County Use Only) Section Township Range Tax Parcel Number 2 9 I I 213 I I ol 4 I I o 10 I B 17 I o 10 I I o 12 I BI o I Site Location Is within the _ GR_EEfi_~IVER drainage shed(s) Pro Rato Share Assessment(s) are: D Required D Not Required for increased storm water runoff. from the site due to development Peak Runoff Assessment Rate($ Peak Volume Assessment Rate('.S ) per c.f.s. lncreases.(10 year, 2 hour storm) ) per Ac. Ft. increase8.(2 year, 2 hour storm) AGREEMENTS, PLAN REFERENCES, PERMITS ETC. (To be completed by Consultant) Preliminary Plat Approval/Permit Issued Date: Expiration Date: Other Related Permit Numbers Received: Right-of-Way Use Permit Grading Build in g/Stru ctu ral Other ______________ _ Boord fee\ of tree removal on site: MARCH 12, 2004 MARCH 12, 2009 NONE Cubic yards of material hauled on/off \he site: Is this a erosion sensitive urea site? (Yes/No): ND Note: If "yes", a Highly Sensitive Site Erosion Control Supervisor is required. See ESC plan and TIR for details. C-------------·------···--------------------1 E'rne'rg enc'y 911 Police-Fire-Rescue >------------·-·-----------·----------------·-- Dote RECOMMENDED FOR APPROVAL (To be completed by King County) Engineer Pion Reviewer Engineer Supervisor Traffic & Planning Engineer Sensitive Areas Structural Review Engineer Other APPROVED F'OR CONS11 f~UCrfION DEPARTMENT OF DEVELOPMENT & ENVIRONMENTAL SERVICES Date King County, Washington James H. Sanders, P.E. Development Engineer PROJECT CONTACT INFORMATION . ___ H_A_M_I_N_}J_C_H_A_U __ __,,( 425) 643-3993 Q_ ..c Q) r I... CJ) Q) <I)~ C C <n 3 ?;; 2 OOf- Narne 4101 150th AVE. SE BELLEVUE, WA. 98006 Address and Zip Code Phone 0 A Partnership £l An Individual ___ I_IA'--__ ii'f_IN_::_:H_C_H ___ A.::..U=--_ ___\_'.( 425) 643-39 g 3 Name 4101 150th AVE. SE BELLEVUE. WA. 98006 Phone L 0 (J) > L Q) Q_ ::J (/) ~ L Q) Q) C Q) C w ~ +-' () Q) +-' .c () L <( C CJ) (J) Q) 0 (J) Q:'. w m 2 ::) z w __J LL (J) w 0 0 " z -a: lU w z -" z w a: w " w 4: J - L (l) .0 E ::J z >, > +-' () <( . . L (l) .0 E ::J z .µ () Q) ·~ 0 L CL ·<t t') ()) 0 I 0 lf) CJJ w u. O'.'. w ('.) w <( --, (fJ w .z <( , (l) C 0 .c (L L 0 _µ 0 C -cJ L 0 0 u +-' () Q) ·~ 0 L CL 0 z +-' C (l) E Q_ 0 (l) > Q) 0 License/Seal . -~ - s.s J.J~ ~ El D Address and Zip Code :' ,~~,"' w,;~,,,l;t t O A Corpora tian , ', -o ,1,y:> · ~ E O A Partnership I \ ,11'1' " ¥ '\ 12'. An Individual l~V"i<"ss•tors""'0:;c,<:', \I) ..cJ_-cA=E::.cG::.:E='R=-::::E:.::.N:...:G::..:I::.:.N.:.::E=E='R=IN:_:..:::G_~(2s3) sso-0934 I \ ')~N:.-}~\}i'lJ\ Narne Phone LEXPIRES: 3/1/2Qig]__ 9419 S. 204 PL. KENT 9S031 Address and Zip Code Sheet 1 of C§ i ' ' \ '. ' I [; f ' ' L t .- Ii ,, '~ ' ' '-Il ' ,, µ, ' . -,, . , ' ,, -.-·.'.·.· i ~ ' I"': -_ .. -:,' ' ' ' . '.'.'! -,:_: '" GENERAL NOTES 1. All construction shall be iri accordance with the King County Code (KCC), Road Standards (KCRS), and the King County Council's conditions of preliminary subdivision approval. It shall be the sole responsibility of the applicant and the professional civil enginesr to correct any error, omission, or variation from the above requirements found in these plans, All corrections shall ue at no additional cost or liability to King County. 2. The design elements within these plans have been reviewed according to the King County Department of Development and Environrrwntal Services (DOES) Engineering Review checklist Some elements may have been overlooked or missed by the DOES plan reviewer. Any variance from adopted standards is not allowed unless specifically approved by King County prior to construction. 3. Approval of this road, grading, and drainage plan does not constitute an approval of any other construction (e.g. domestic water conveyance, sewer conveyance, gas, electrical, etc.) 4. Before any construction or development activity, a pre-construction meeting must be held between the DDES's Development Inspection Unit, the Applicant, and the Applicant's Construction Representative. 5. A copy of these approved plans must be on the job site whenever construction is in progress. 6. Construction noise shall be limited as per King County Code (Section 12.88); normally, this is 7 a.m. to 10 p.m. weekdays and 9 a.m. to 1 O p.m. on weekends. 7. It shall be the applicant's/contractor's responsibility to obtain all construction easements necessary before initiating off-site work within the road rights-of-way. 8. Franchised utilities or other installations that are not shown on these approved plans shall not be constructed unless an approved set of plans that meet all requirements of KCRS Chapter 8 are submitted to the DDES's Development Inspection Unit three days prior to construction. 9. Datum shall be KCAS unless otherwise approved by DOES. 1 o. Groundwater system construction shall be within a right-of-way or appropriate drainage easement, but not underneath the roadway section. All groundwater systems must be constructed in accordance with Section B1 3.02 of the APWA Standard Specifications. 11. All utility trenches shall be back filled and compacted to 95 percent density. 12. All roadway subgrade shall be back filled and compacted to 95 percent density (WSDOT 2-06.3). 13. Open cutting of existing roadways is not allowed unless specifically approved by DOES and noted on these approved plans. Any open cut shall be restored in accordance with KCRS 8.03(8)3. 14. The Contractor shall be responsible for providing adequate safeguards, safety devices, protective equipment, flaggers, and any other needed actions to protect the life, health, and safety of the public, and to protect property in connection with the performance of work covered by the contractor. Any work within the traveled right-of-way that may interrupt normal traffic flow shall require at least one flagger for each lane of traffic affected. All sections of the WSDOT Standard Specifications 1-07.23 -Traffic Control, shall apply. DRAINAGE NOTES 1. Proof of liability insurance shall be submitted to ODES prior to !he pre-construction meeting (KCC 9.04.100.D). RIGHT-OF-WAY LINE DRIVEWAY -CURB (S[E SEC. FIG 3-012) ® 3/8" EXPANSI01\J JOINT (T(P.) DETECTA3LE WARNING PATTERN (SEE DETAIL) - S:OEWALK -- .... f--~ MIN, ! : .. ' CURB TAPER CUT -CURB, OR CURB Ai'\JD GUTIER NOTES: 1. SEE SEC. 3.04 K,C.R,S, FOR JOINT REQUIREMENTS, 2. ROLL GUTTER TO MATCH POSITIVE SUPERELEVATION, 3. SEE DRAWING NO, 1-006 FOR CONFIGURATION OF FILL & WALKWAY BEHIND CURB IF REQUIRED, 4. FOR INTEGRAL POUR CONSTRUCTION, 1 / 4" EDGED GROOVE MAY REPLACE EXPANSION JOINT AT INTERFACE BETWEEN THE CURB AND ADJACENT SIDEWALK. SEE SEC. 3.03 FOR EXTRUDED CURB ANCHORAGE, SiOEWALK PLANTING STRIP R:GHT·-Q;;--WAY LINE SECTION A-A CE!..'.!':NT CONCflETE DRIVEWAY 5" THICK 9'-0" 16" 5'-0" ( ANCHOR BOLT PATTERN PER NDCBU PEDESTAL TEMPLA 7£ [-lT 3/8" x FULL DEPTH 6"1 I EXPANStON JOINT ~.sLCJ. 1 ·~ ". .... ·' . . ' <o I ? 10'-o" 10'-o" ----------® _J~ .· 2.0' MIN FOR TRUNCATED ~ OOME SECTION PVMT. TEXTURE CEMENT CONCRETE SIDEWALK AND RA,IP --_!!' MIN. 12 ,tATCH EXISTING OR PROPOSED SURFACE I -----i 1 --ASPHALT CONCRETE ~·~~~~~s»'§>~,£Fo/;~'\ SHOULDER ' --------~S~E~C~T~IO~N_,_,A_,_--'A, ________ _ NOTE;i_ 1. SEE SEC. 3.02 FOR SIOEWALK WIDTHS. 2. SEE SECS, 2.02 AND 2.03 FOR PAVEMEf!T AND SHOULDER WIDTHS. 3, SHOULDER SHALL BE SURFACED AS REQUIRED BY SECS, 3,07 AND 4,01, PAVED SHOULDER SLOPE SHALL MATCH CROWN SLOPE OR 0.02 FT/FT. 4. SEE FIG. 3-001 FOR CURB AflD SIDEWALK JOINTS. ® RAMP SHALL BE TEXTURED USING TRUNCATED DOME PATTERN. (SEE FIG. DETECTABLE WEARING PATTERN SHALL BE YELLOW IN COMPLIANCE WITH WSDOT STANDARD SPECIFICATIONS 8-14.3(3) 6. THIS DETAIL APPLIES TO ROLLED AND Vi:RTICAL CURB f<OADWAYS. SIDEWALK TRANSI1'ION RAMP N.0.CB.U 11Ev1SIONS: . REV. PER CTY, OMMENTS 10-1-0- (j z er w w z (j z w er w (j w ~ <( 3-01' -Pz J 2. All pipe and appurtenances shall be laid on a properly prepared foundation in accordance with WSDOT 7-02.3(1). This shall include leveling and coinpacting the trench bottom, the top of the foundation material, and any required pipe bedding, to a uniform grade so that the entire pipe is supported by a uniformly dense unyielding base. ---CROSSWJ-\LK I . 1'-6". I ? -+------------,,,--,----,----.---.---~---------__(__ CUTLER MODEL CB-6 OR EQUAL~ &-t 3. Steel pipe shall be galvanized and have asphalt treatment #1 or better inside and outside (KCRS 7.03). 4. All drainage structures, such as catch basins and manholes, not located within a traveled roadway or sidewalk, shall have solid locking lids All drainage structures associated with a permanent retention/detention facility shall have solid locking llds (KCRS 7.05). 5. All catch basin grates shall conform to KCRS drawing numbers 2-013, 2-016, 2-019, or 2-020. which includes the stamping "OUTFALL TO STREAM, DUMP NO POLLUTANTS" and "Property of King County" (KCRS 7.05). 6. All driveway culverts localed within King County right-of-way shall be of sufficient length to provide a minimum 3:1 slope from the edge of the driveway to the bottom of the ditch. Culverts shall have beveled end sections to match the side slope (KCRS 7.D3(L), Drawing No.2-001). 7. Rock for erosion protection of roadway ditches, where required, must be of sound quarry rock, placed to a depth of 1 foot, and must meet the following specifications: 4"-8" rock/40%-70% passing; 2"-4" rock/30%-40% passing; and -2' rock/10%-20% passing. Installation shall be in accordance with KCRS 7.02(8) drm1ing number 2-024. 8. Drainage outlets (stub-outs) shall be provided for each individual lot, except for those lots approved for infiltration by King County. Stub-outs shall conform to the following: a) Each outlet shall be suitably located at the tow est elevation on the lot, so as to service all future roof downspouts and footing drains, driveways, yard drains, and any other surface or subsurface drains necessary to render the Jots suitable for their intended use. Each outlet shall have free-nowing, positive drainage to an approved storm water conveyance system or to an approved outfall location. b) Outlets on each lot shall be located with a five-foot-high, 2" x 4" stake marked "storm" or "drain". The stub-out shall extend above surface level, be visible, and be secured to the stake. c) Pipe material shall conform to under drain specifications described in KCRS 7.04 and, if non-metallic, the pipe shall contain wire or other acceptable detection. d) Drainage easements are requirud for drainage systems designed to convey flows through individual lots. e) The applicant/contractor is responsible for coordinating the locations of all stub-out conveyance lines with respect to the utilities (e.g. power, gas, telephone, television). f) All individual stub-outs shall be privately owned and maintained by the Jot homeowner. FIRE HYDRANT OR UTILITf POLE LUMINAIRE 0 Ml . ~ PLANTING STRIP ~ ~~ is SIDEWALK NEXT TO VERTICAL CURB ___, I 50' MIN SIDEWALK - CURB RAMP 1 A @ '! ------CEMENT CONC. S!JEWALK RM~? TYPC lr'\ DETECTABLE WARNING PATTERN AREA SHALL BE A YELLOW, IN COMPLIANCE B WITH STD. SPEC, 8-14,3(3)----,_' -" I @ © A @ .! ® @ ' !O PLAN C " -0 ELE,VATIQN ---f B -! PLAN LAYOUT 1 DETECTABLE WARNING PATTERN DETAIL NOTES 1, PLACEMENT OF GRATINGS, ACCESS COVERS AND OTHER APPURTENANCES SHALL NOT BE LOCATED ON CURB RAMPS, LANDINGS AND GUTTERS WITHIN THE PEDESTRIAN ACCESS ROUTE, @ RAMPS SHALL BE TEXTURED USING TRUNCATED DOME PATTERN (SEE DETAJL THIS PAGE), DETECTABLE WARNING PATTERN SHALL BE YELLOW IN COMPLIANCE WITH WSDOT STANDARD SPECIFICATION 8-14.3(3) 3. PAMP CENTER LINE SHALL BE PERPENDICULAR TO OR RADIAL TO CURB RETURNS UNLESS OTHERWISE APPROVED BY THE COUNTY ROAD ENGINEER. 4, PAMPS SHALL BE CONSTRUCTED AT CORRESPONDING SIDEWALK LOCATIONS ON OPPOSITE SIDE OF STREETS WHEN RAMPS ARE CONSTRUCTED ON ONE SIDE OF STREET. SEE FIG. 3-010, @ LANDING SHALL BE MINIMUM 4 X 4', @ CURB RAMP IA MUST BE INSTALLED UNLESS OTHERWISE APPROVED. 7, SEE FIGURE 3-001 FOR CURB AND SIDEWALK JOINT PLACEMENT. 1. HANDICAP RAMP STREET TREE NOTES: TREES SHALL GENERALLY BE PLANTED BACK OF THE SIDEWALK. PLANTING STRIPS WILL BE APPROVED ONLY AS PART OF A LANDSCAPING PLAN IN WHICH PLANT MAINTENANCE, COMPATIBILITY WITH UTILITIES, AND TRAFFIC SAFElY ARE DULY CONSIDERED, NOTE 1,--L-_/ VERTICAL CURB LINE STREET TREE NOTES: STREET TREE 1. TREES TO BE PLANTED AT APPROX. 40' ON CENTER, WITH ADJUSTMENTS FOR UTILITY FIXTURES AND MAILBOXES. 2. HOMEOWNERS SHALL BE RESPONSIBLE FOR TREE MAINTENANCE FOR TREES WITHIN OR ABUTTING LOTS. 3. STREET TREES SHALL BE: l-Jl.fl.i.)( DC01DC:Hff'it...l:S ( WESIF"fN L!\f<CM) LOCATE 5' BEHIND THE SIDEWALK (OR CURB, IF NO SIDEWALK) AT INTERSECTION 2. STANDARDS 3. IF PLANTING STRIPS ARE APPROVED: A MIN. DISTANCE FROM CENTER OF ANY TREE TO NEAREST EDGE OF VERTICAL CURB SHALL BE 4 FEET. B, TREES SHALL BE STAKED IN A MANNER NOT TO OBSTRUCT SIDEWALK TRAFFIC. C, IN CASE OF BLOCK-OUTS, MIN, CLEAR SIDEWALK WIDTH SHALL BE 5 FEET IN RESIDENTIAL OR 8 FEET IN BUSINESS DISTRICTS. ON BUS ROUTES, PLANS SHALL BE COORDINATED WITH METRO SERVICE PLANNING. PHONE 684-1 622. SIDE VIEW TRENCH X-SECTION NTS r 6" 2' o" ' a I a, 2'-0" I NO CHU 1 _~_ 1 +- ' "' FACE OF VERTICAL CURB PLAN VIEW NEIGHBORHOOD DELIVERY & COLLECnON BOX UNIT (N,D.C.8.U.) INSTALLAUON NOT TO SCALE s/op9- 000 sq. ft. > 700 sq. ft. PLAN VIEW OF ROOF NTS small calch basin or yard drain /, 2' X 10' - ,, ~ ~ Type I i - -" - level lrenches CB slandard dispersion lrench I w/ notched grade board englh 1 O' per 700 sq. ft. of roof area, s ee Figure 4.2.2.C of the urtace Water Design Manual s INDIV. LOT DOWNSPOUT DISPERSAL TRENCI-I ' "1 "' ' ~ "1 I ' 'T ~ 'f'l ,,, I -,, ) . ' <o . I - ' till I - . -] I •• .. . ' . '' I ,. ,, . . ,, . ' • •' Ff?ONT VIEW . ( • ~ k:l ~ ....; Cl} Pq . ~ . King County ~ Department of Devaloprn~nt <Jnd Environmental Services APPROVAL FOli SITE CONSTRUCTION - Review Engineer ENGRCOMP Date Senior Engineer ENGRCOMP Date -- DEVELOPMENT ENGi Ne ER APPROVAL Date Comments: ~ ~ &-t ~ ~ 1/J ~ o· tr: ~ ..; "1 tr.i .q i:::i ..., ~ &-t ~ 0 0 ... i...:i "it ~ <n 0 ..; Cl';) ('-. ~ ... ~ f' ~ l) w -, 0 (>'. 0. <n ::::> ~ 0, ~o°' ~ c:,<n , c:o I [;: 0, ~ ""1 • ~ ~ ;'.'l .q i,::-.., ...., lQ c:, P<i' <:\! ~ ~t2~ kl . ~ c3~~ :;;: ~ tti 0.. "' z <( l) :J 0. 0. -<( DATE: 3/16/07 SCALE: 1" = 30' DESIGN BY: JJJ DRWN. BY: JJJ APP. BY: FILE No, SHEET 3 OF 5 -------------------- ,-----------------------~-----------------·-----------------·------------···-------~--------·------·--- A PORTION OF THE SW 1/4 OF SECTION 29, TWP. 23 N., 4. r C..' W. tv1. RGE. REVISIONS: . REV. PER CTY. "-:OMMENTS 10-1-D~ EROSIOI\I AND SEDIMENTATION CONTROL NOTES 1. Approval of this erosion and sedimentation control (ESC) plan does not constitute an approval of permanent road or drainage deriign (e.g. size and location of roods, pipes, restrictors, channels, retention facilities, utilities, elc.). 2. The implementation of these ESC plans and the construction, maintenance, replacement, and upgrading of these ESC facilities is the responsibility of the applicant/ESC supervisor until all construction is approved. 3. The boundaries of the clearing limits shown on this plan shall be clearly flagged by a continuous length of survey tape (or fencing, if required) prior to construction. During the construction period, no disturbance beyond the clearing limits shall be permitted. The clearing limits shall be maintained by the applicant/ESC supervisor for the duration of construction. 4. The ESC facilities shown on this plan must be constructed prior to or in conjunction with all clearing and grading so as to ensure that the transport of sediment to surface waters, drainage systems, and adjacent properties is minimized. 5. The ESC facilities shown on this plan are the minimum requirements for anticipated site conditions. During the construction period, these ESC facilities shall be upgraded as needed for unexpected storm events and modified to account for chunging site conditions (e.g. additional sump pumps, relocation of ditches and silt fences, etc.). 6. The ESC facilities shall be Inspected daily by \he applicant/ESC supervisor and maintained to ensure continued proper functioning. Written records shall be kept of weekly reviews of \he ESC facilities during the wet season (Oct. 1 to April 30) and of monthly reviews during the dry season (May 1 to Sept. 30). 7. Any areas of exposed soils, including roadway embankments, that will not be disturbed for two days durin9 the season or seven days during the dry season shall be immediately stabilized with the approved ESC methods \e.g., wet seeding, mulching, plastic covering, etc.). 8. Any area needing ESC measures, not requiring immediate attention, shall be addressed within fifteen (15) days. 9. The ESC facilities on inactive sites shall be inspected and maintained a minimum of once a month or within 48 hours following a storm event. 10. At no time shall more than one (1) foot basins and conveyance lines shall be cleaned water into the downstream system. of sediment be allowed to accumulate within o catch basin. All catch prior to paving. The cleaning operation shall not flush sediment-laden 11. Stabilized construction entrances and roads shall be installed at the beginning of construction and maintained for the duration of the project. Additional measures, such as wash pads, may be required to ensure that all paved areas are kept clean for the duration of the project. 12. Any permanent flaw control facility used as a temporary settling basin shall be modified with the necessary erosion control measures and shall provide adequate storage capacity. If the facility is to function ultimately as an infiltration system, the temporary facility must be graded so that the bottom and sides are at least three feet above the final grade of the permanent facility. 13. \/mere straw mulch for temporary erosion control is required, it shall be applied at a minimum thickness of 2 to 3 inches. 14. Prior to the beginning of the wet season (Oct. 1), all disturbed areas shall be reviewed to identify which ones can be seeded in preparation for the winter rains. Disturbed areas shall be seeded within one week of the beginning of the wet season. A sketch map of those areas to be seeded and those areas to remain uncovered shall be submitted to the DOES inspector. The DOES inspector can require seeding of additional areas in order to protect surface waters, adjacent properties, or drainage facilities. CATCH [3_,il,SIN_!N.$EEIT i\l,AINTENANCE STAND1\RQS 1. ANY ACCUMULATED SEDIMENT ON OR AROUND THE FILTER FABRIC PROTECTION SHAI_L BE RE,'vlOVED IMMED'/>.TEL Y SEDIMENT SHALL NOT BE REMOVED WITH WATER. Ai\JD J1LL SEDIMENT MUST BE OF A.S FILL ON SITE OR HAULED OFF SITE. DISPOSED 2. A;\JY SEDIMENT IN THE CATCH OAS,N INSERT SHALL c3E REi\JIOVED WHEN THE SEDIMENT HAS FILLED ONE-THIRD OF THE J1\/AILJ\BLE STORAGE THE FILTER i\JIEDIA FOf\ THE INSERT SHALL BE CLEANED OF, F!EPLACFD AT LEAST MONTHLY. - 3. REGULAR MAINTENANCE IS CRITICAL FOR BOTH FORMS OF CATCH BASINS PROTECTION. UNLIKE MANY FORMS Or-PROTECTION THAT GRADUALLY, CATCH BASIN PROTECTION WILL FAIL SUDDENLY AND CO,MPLETEL Y IF NOT MAINTAINED PROPERLY. CF~!\TE -\ "~\;(\~**~~"%~~~"%~\ ·\\(~~~~~~1· :.-;.. , ' NOTE ONLY TO BE USED • WHERE PON Di NG OF WATER ABOVE THE CATCH BASIN WILL NOT CAUSE TRAFFIC PROBLEMS AND WHERF OVERFLOW WILL NOF< f<ESULT IN EROSION OF SLOPES. \ . . JF!L TEREDI ~ ~~"~/,:_;~ "-..'·-CATCH BASIN CATCH BASIN INLET FILTER F Al L. STREET TREE -WESTERN LARCH (LARIX OCCIDENTALIS) PLANTED-~----. 5' FROM R.0. W. LINE ( 4 TREES) --. ,, LEGEND CLE:ARING LIMITS TE:MP CB FIL TE:R PRDPDSE:IJ CDNTDUR EXIST. TRE:E: SSMH RIM=376.5 {/tk CJ) 10" ;..V P!NES BLOCK 4 AKER'S FARMS ND. 5 27 VOL 40, PAGE LDT 12 130.01' 300.01' (CALC) GRAPHIC SCALE CONS1'1?UC1'ION SE'QUENC'E' 1. Arrange and attend a preconstruction meeting with King County DOES Inspections Unit. Call (206) 296-6642. 2. Flag clearing limits and easements. Flag property lines. 3. Post sign with name and phone number of ESC supervisor. 4. Flag all trees that to be saved. 5. Grade and install quarry spall construction entrance. 6. Install silt fencing as shown on the plans. 7. Maintain erosion control measures in accordance with King County standards and manufacturer's recommendations. 8. Relocate surface water controls or erosion control measures, or install new measures so that as site conditions change the erosion and sediment control is always in accordance with the King County Erosion and Sediment Control Standards. 9. Cover all areas that will be unworked for more than seven days during the dry season or two days during the wet season with straw, wood fiber mulch, compost, plastic sheeting or equivalent. 10. Stabilize all areas within seven days of reaching final grade. 11. Seed or sod any areas to remain unworked for more ttian 30 days. 12. Upon completion of the project, stabilize all disturbed areas and remove BMPs upon approval of the Inspector. (, 1--- J I l __ DT I E>: HOUSE I I L .--- 13 King County Department of Development and Environmental Services APPROVAL FOR SITE CONSTRUCTION -------·--------, -·-----1 i -- IGRCOMP Date Senior Engineur-ENCRCOMP Date 20 0 10 20 40 80 ~~-. ··. ·=~==: ... -b .. , ........ Y"'"'""''~~~j ~~-iJ¥f~~---::::, !-------··------+--=----DEVELOPMENT Er·IGINEER APPROVAL Do\e- Cornments: ·-------1 1---------- (j z (Y. w w z (j z w --a;: ---.. G:::,. ,--- . .cl. ~ i·i. -1"') _JI', ~ . ~ "1f!'"' ', tf\°'o , N "§ ~ .\% 0 _,~/> s Q ,-r{"'"' ~ ·~ -~ ?"" .... .(. - t-t ~ c3 ~ ~ ~ 0 ~ ~ v "'-1! t/J ..q g ..., &-, (0 VJ Cl 0 . .., "<l >-:I 'i< 2; C') a <:::, (/) C1'j I:'--, Cl t::) &l ~ ~ ~ N ;:_; (j h u w ~ 0 c,: Q. DATE: 3/16/07 SCALE: 1" = 30' I------·---' DESIGN 8Y: _ _llJ_ DRWN. BY:--.,b/_J_ APP. BY: t--·---·----- FILE No. B" ( IN l'EET ) 1 in~=~ ~-4 Plum SHEET -~~- ..... --------------------------------------------------------------------~R~E~M~O~V~E--------------------------------------------·-~===== "---==~=============--..L-o-F ___ 5 __ ..J N.T.S. EXIST. TREE TD BE REMOVED _,;;_ __ _ --·-----~ ------- Flfff HYDRANT OR UTILITY POLE LU MINAR STREET TREE NOTES: 1. TREES SHALL GENERALLY BE PLANTED BACK OF THE SIDEWALK. PLANTING STRIPS WILL BE APPROVED ONLY AS PART OF A LANDSCAPING PLAN IN WHICH PLANT MAINTENANCE, COMPATIBILITY WITH UTILITIES, AND TRAFFIC SAFETY ARE DULY CONSIDERED. 2. IF PLANTING STRIPS ARE APPROVED: A. MIN. DISTANCE FROM CENTER OF ANY TREE TO NEAREST EDGE OF VERTICAL CURB SHALL BE 4 FEET. B. TREES SHALL BE STAKED IN A MANNER NOT TO OBSTRUCT SIDEWALK TRAFFIC. C. IN CASE OF BLOCK-OUTS, MIN. CLEAR SIDEWALK WIDTH SHALL BE 5 FEET IN RESIDENTIAL OR 8 FEET IN BUSINESS DISTRICTS. 3. ON BUS ROUTES, PLANS SHALL BE COORDINATED WITH METRO SERVICE PLANNING. PHONE 684-1622. SIDEWALK NEXT TO VERTICAL CURB '.i' I ~ ~O Ml . < NOTE 1.-"'-__, VERTICAL CURB LINE AT INTERSECTION STREET TREE NOTES: 1. TREES TO BE PLANTED AT APPROX. 40' ON CENTER, WITH ADJUSTMENTS FOR UTILITY FIXTURES AND MAILBOXES. 2. HOMEOWNERS SHALL BE RESPONSIBLE FOR TREE MAINTENANCE FOR TREES WITHIN OR ABUTTING LOTS. 3. STREET TREES SHALL BE: LARIX OCCIDNETALIS (WESTERN LARCH) LOCATE 5' BEHIND THE SIDEWALK (OR CURB, IF NO SIDEWALK) STREET TREE STANDARDS CATCH BASIN J1\iSFRT lvl/\ltrCENANCE ST/\.ND.2,PDS I. ANY ACCUrvlUl.ATED SEDIMENT ON OR AROUND THE FIL TEF< FA.BRIC PROTECTIOl'i SHALL BE REl,~OVED IMHEDIA TEL Y SEDIMEI\! T SHALL NOT BE REMOVED WITH WATER, AND ALL SEDIMENT lvlUST BF OF AS FILL Oi'.j SITE OR H,~ULED OFF SITE. 2. ANY SEDIMENT IN THE CATCH BASIi\! IIJSEF,T SHALL BE RE1v10VED WHEN THE SEDlivlENT HAS FILLC:D ONE-THIRD OF THE AV/1IL/\BLE STOR!1GE. THE FIL.TU\ MEDIA FOR THE il'ic;ERT SHALL BE CLEA.NED OR REPLACED AT LEAST lv\01,THL Y 3. F,EGUI .. AR tvlA!NTENANCE IS CF,ITICAL FOR BOTH ,"ORMS OF CATCH BASINS PF,OTECTION. UNLIKE MAI\IY FORlvlS OF PROTECTION THAT GRf\DU ALLY, CATCH BASIN PROTECTION WILL FAIL SUDDENLY AND COMPLETEI_ Y IF NOT lvlAINTAII\IED PROPERLY NOTE: ONLY TO BE USED WHERE PONDING OF WATER ABOVE THE CATCH rll\Sll•I WILL NOT CAUSE TRAFTIC PROBLEMS AND WHERE 0\/ERi'LOW Wll_L NOR RESULT IN EROSION OF SI_OPES. ' CATCH- BASIN CATCH BASIN INLET FILTER !\J. T S FAIL A PORTIOt~ OF THE SW 1 /4 OF SECTION 29, TWP. 23 N., RGE. 4 E., W.M. NO REPLACEMENT TREES ARE REQUIRED OR PROPOSED. BLOC!< 4 AKER'S F ARHS ND. 5 VOL 40, PAGE 27 LDT 1? TREE INVEN-10RY: 13 SIGNIFICANT TREES: 7 TREES TO BE RETAINED 6 TREES TO BE REMOVED F\EQUIRED TF~EE RETENTION (PEF,; KCC 16.182 .. 156) 5% OR 10 TREES PER ACRE (WHICHEVER GREATER) SITE AREA: 0.34 ACRES 0.34 (10) = 3 TREES REQUIRED TO BE RETAINED 300.01' (CALC) 300' (PLAT) 130.01' LEGEND CLEARING LIMITS PROPOSED CONTOUR ~ ----~ EXIST. TREE TO eE. ~\/ED *10" PINE EXIST. TREE ~10" f'INE J I GRAPHIC SCALE ( IN FEE'r ) 1 inch = 20 ft. ' CD (\j (J', Is I LDT 13 ----_I EX HOUSE L _ -- King County Departm(,nt of Di:velopment and Environmenta! Services --~ APPr,OVAL f'Of< SITE CONSTF<UCTION ----------~--~---t-------1 Review Engineer E~IGRCO/vlP Date >------~·--·---+-~-ENGflCOMP Date Senior Engineer DEVELOPMENT ENGINEER Comments: APPROVAL Date REV1SIONS: ,1 _E['L£ER (;TY. :OMMENTS 10-1-07 --------- ~--·------ 1------- --------, ~·-------- G z .. c:.J'.__;Y h :s ~ h r~ ~ VJ 0 ~ ~ ;,.. 3 ~ :S 1:1.., h ~ kl 0 0 -, kl i:i:; .....;i 'sj< &< C") 0 ~ ('s. ~, b ~ "' u () w 3 "' [L "' ~ kl (0 0, ~ iJl O ~ c:, I • co t'.: 0, ~ s,; • 'O • :-s: ~ £1 iii:: "°" .,.., lQ ~ c:, • (\/ ~ ~~~ o~~ ~ ~~~ "' 2: <( u :J o_ [L <( DATE: __lil6/07_ SCALE: 1'' = 30' DESIGN BY, JJJ DR~. BY: JJJ ~- APP. BY, FILE No. SHEET 5 OF . 5 __ -~·--------·-·-----·------------------ '1 I ' ' I I I I I I I. / CONDITIONS OF APPROVAL <® King County Department of Ot1velop1rn.<11t and Environmental Services 900 Ooi~es(J;;le Averue SW Renton, WA 90055-1219 File No File N,11ne: CO:\DITJO:",'S OF APPROVAL LOJS0016 Cliau Sliort Plat Application Date: ~fay 2, 2003 January 30, 200--1 Revision Date: Tliis shurl subdivision is g1anted prelimi11c1ry appro\'al subject to th.e :ollov,·!ng Cunditi?us of Appro"al. These conditiuus are based on a field visit and current. mlurmat.wn the ~pplt~•:nt has provided about the shoi t subJ[\·ision property. Occasionally, Ill sr1tJsfymg tlie Cond1t1011s of Approval, a more tk!iniliH· land use limitation of the propen~ rnay be rcn:::led. ~c_w information (such :is final J kalth l!pprO\'Cii or sensitive an:as review) may r<:q\111·c ad<lrnorial conditions and may reduce the m1mber of lots. Final approval will k gr:rntcd after compliance with the Conditions of AJ'.proYctl. Kcy codes and guide!im:s Jiavc beL'!1 uoted to pro,·idc guidance in pr..:paring t!1e r..:qu.ued pl.His ~1,d o'.hcr d0cumcnts. Compliance 11 iLh some of tile following conditions will require that engrneermg plans be prepared by a prol'essional ci1·it engineer licensed in the State ofWashlllgton. !. Title 19A 2. 3. A. D. The sho 1·t sublli\'ision s!rnll com;ily 11ith all pro1·isions of Title ! 9A. The final re,·iew prc.)(.:ess must be cornpkted prior to recording of Lh<: short ~ubdi1·ision. The Department ofDeYdopmcnl :md Environrncntal Sen-ices (DOES) strongly recommends the final Shoi1 Plat be s_1,1bmitted at least one y~11 r IJi-ior (q.Ll1~e,pirntion date of1he E!:9ii,;.Ql. The Final Short Pl,1t wbmittal pack:1ge induJt's: J. A sun·eyed map page (four S\:'ls) induding lot an::a c-!oSure calculations; 2. furnl lieailh approval from die King County Health Department (Jiffrrent from p1dim111ary health approYal); 3. A emre 11 t short plat ce11ificate and supporting documents (e,ise111ents, e'.c.); 4. Payml'nt of the Final Short Plal submittal fee; 5. A copy ol'this letrnr (prelimin:iry approval leller) A licensed i:1nd sur\"eyor shall b,; hired to prepare (he f'imil short subdi1·ision documents. These documerlls sh:ill comply wi:h all of the following condiiious ((If ti11al appro\·al: C. All persons liaving an ownership interest in the subject property are requlred to sign (he ll!ial sbort subdivision. D. Ifmodi!kations to the approved preliminary site plan (t\llaclimcnt J) are needed to accomplish engineering design or final shQ11 plat, then u re\'ised preliminary site plun stmll be submitted to DDES for rc\·iew and appro\'al. The revised site plans slmll be s11bmitted with the engiu~·cflng plans or tbe final sliort plat submi!!al. Surface Water :\follUgcment (!<CC 9) 1998 King County S1irfacc Wa(cr Dcsign .\l:\Jlual (SWD:\[) A. This short stibdivision proposal is Sl1bjec( to full Draln::ige Review per section 1.1.2.3. Fin,d shon subdil·i~iou uppro\'a! sh.ill require full comp!ia11cc with drainage prol'isions and storm drainage requirements of this section. Compliancc inay result in reducing tl1c mmibcr and/or location of lots shown on the appro1·ed prdiminary slwrt subdivision. Tlie conditions outlined below arc site-specific drainage conditions: {I) Corl' Hcquircmcnt #1 • DisclrJrge at the Natur,il Loc,uio11 (2) Core Hcquircmcnl #2 · Off-Sile Allalysis (3) I!) (5) (6) (7) (8) (SI) Core Hcquirl'lllenf #3 -Flow Control '-'-'' ' C,c, Cure 11:ctpiil'cmcnt #4 -Co11Yeya11ce Syslem Con· Jkquinmcnt #5 -Ernsion & SeJimen1,11io11 Control Core Hcquirrn1e11t #6-'\Jaintc11ai1ci.: :1nJ Operation Core Requirern,·ut #7 -Fimncial G11ar:mtees & Li:1bility Corl' He<Jtzircml'Jtt #8 -\Vater Qu:ility .Special Requirement #1 -Other Adopted Requircmc1jts B. r\ professional Ci\'i] engineer licensed in th<: State <Jf\\'ashington shall prepare a Technical Jufonnmion Report auc.l/or engin<cer1ng plans pa Ch2pter 2, of the 1998 King Cotmty Surface Water D-:sign ,\lanual. lfoalth (KCC 13) This prnject is exempt from funl1cr King County Jfrath Department review. Howne1·, if i111prnYc111en:.s a;e rcq uired from the Sc11 er ,md/or ;lie \\'nter District, tl1en 1·criikatiun shall be required from Sdid LJistric!(s) that the improvements have been bonded and/or installed, pl'ior to final recording of the ~horl plat. 4. Road S!undards (KCC 14) 1993 King County Ro:id St:111d11rds, Ordinance 11187 Final short subdivision approval shall require full compliance ll'ilh the pro\·isions set forth in the Ki11g County Road Standards incluJing engineering plans for all ro:id improvemems. The engineering plans shall be prepared by a prufcssional civil engi1wer licensed in the Srnte of Washington. DDE:S strongly recommends the En!!im:1:rint! Plans be submilled at least t\\'o_y~ars mior to the C\Q!i.ttion dnte ofthu pro1cct. A. Tlrnt purl ion of the North half of SE J 72"J Street adjoining die subject propi;:rty shall be impro\'ed to an urban Sub-accr:s~ standard per KCRS S,.:eiion l.03. B. That por1ion of the East half of l 06'" A \'enue SE adjoining the subject property shall be improved lo an urban Sub-access standard per KCRS Section J .03. ,,.- 5. 6. 7. _ .. ~ .• C. D. 1·. (_/, The fullli 11 i11g not..:s shall[,._: sholl'n on ch·: li11a! rtconled shon subdiYision: I) ,, \'_"arni_ng: Kin~: County li:1s nu rl·spunsibility to build. i:npro\'e, 111.1m_ta_m or oth•:rn 1~e scnx...: 1Ji,· )11-il":ile roads cont:iincd within or 11rond1ng sen ice· !u the Jlfl)pc'rty 1k:.cribed in this slirnt ~ubdii·ision. ·:\JI ~rinlte <:cesuJh'llts and/or tr .1c·ts tu be maintained. rl';c:iired, aml/or irbu11lbJ'lll..:1J11r·•rs"fili· ·····]·]· · I J · i ,·. -,· _ ---~ ,., ~p .. ,1.i:~ 1,11ing egc1 ac,:e\slhcreil"omand l.lClt hLlf~. as:1_gns or suci:es~or-,. u:1le:,;s aud until sudi ro,1ds are 1~1:prO\:~d to h,rng County ~lE!l(lcirds ,1m\ ari; J-:dic:ilc'd ;md accepted by Kmg County /or ma111te11n11;,:e. A;J milities witli.n.rruposed ricrl\1,-u<"-11 . .-, ,J,·,11 '•.,·.,·I J J -· · .. I· c, · • "J ., , L;~ , c u ,; ·.1·11rnn ,, rranc 11se <ippro\ed by the Krng Coumy Cot111c'il p1·ior Lo final sl1ort ~ubLiil-i.~io;l r..:eOJ clmg. H. All restrictions, casements, tracts, .ind their purpose shall be shown on the final rccurded short subdivision. Building and Construction Stund:1rd~ Cntle 16) Grading. The: applic:int shall ~·ornply 1;-itli all upplicable prnl"isions ufKCC 16.82. fire Code (KCC 17) Srctio11 902 of the 1997 Edirion of lluiforrn Fire Code The :1pµlicm1t shall olnain the appro1·a] of the King County Fire Protection Engineer for thl' adequal')' of the flre h)dnrni, water m:\in, and fir..: flow stand:Lrds ofKCC 17.08 prior to recoding of the lots. Zuuillg Code (!,cc 21.-\) A. Dcmity and Dimensions (KCC 2 l A 12) All Jots slwll meet the demi1y and dimensions rcoui1·cments oftlie R-~-SO zone c]ussifkmion or shall be as shown on the fa~e of the approYed prelimi- na1y sho11 Sl!bdiYision. 1diicheYer is larger. /\linor re1·isions to the short subdiYision, which du not result in substanli.il changes ancilor do not create additional lots 1nay be -.ippro\·ed at lh<: discretion of LUSU. !3. StreetTn::es(KCC21:\.16) Street trees shall b:: pro1 idcJ along tliat ponion of the ril!ht-of-,\·ay fo1 l 06';' A 1·enu..: Sot!thcJst a11d Sou the.isl 1 72"d S tn:,:t ,1but~ng tlie subjc:ct prn1m1y, pursuam !O the rrc11·ision> of KCC 2 J..\. 16.0)0( I::) :md KCC 2 JA .. 16. J 90, lllllcss existing trL'e'> :>1i.: shown to be equi1·,1knl lo tile rec;11iremrnl of.Code. Sc-e note bL·ltJII', Thi: required SIJ"l.!Ci trees shall be designed as 10 location and sp:icing on Lhc final plan submiu,d. The street trees must be ins ta I led and inspected, or .1 pc·rformance bond posted. prior lo recordi1:g of the pbc !Ca perfo:·111,111ce bond is posicd, the s(rcet trees must be instulleJ and insp1.'cted within Olll' h'ar of recording of the pl,,t. At the time of inspection, if the tree~ are found w 1,e i11.,talled per tlie appn.J1eJ plan, a 111ai11temrn~·e bond rnust be SLlbrnill<:tl, or the pe1-formance bond replaced with a m,1intenance bond, and held for 111ll: year. .tdler ow: ycu, tile mainteri,mce bond may be rckaSL'd after ODES Lis completed a second inspection and di.'lermined 1!1a1 the trees ha\'e bL·en :.::ept healthy aml 1hri1·i11g. i\OTE: l. KCC 2L-U6.050 Landscaping-street frontages The average width of perimeter bndscaping a Ion~ str<cet fronrnges shall be pro\'ided as follo·s,: ror single-family subdi1·i~io11s: ,:. l_'rl.'es slwll be planted at th..: rnte of one tree for e\'ery 40 fed of . ·lrontagc along a neighborhood collector ~,reet or ,:rterial street. IJ The trees shall be: L Locate_d within tlie strc\!t right-oJ:w.iy if permitted by llie custod1al sta1e or local agc11t·y; 2. No more tlia11 20 ft'et from the street right-of-w:iy line when located withm a lot; 3. Ma_intaincd by (he adj11cen! landowncr unkss part of a Countv marnter:aiK·e program; and · 4. A species app1·01·ed by the County ifloeatcd within the strret right-of-way and compatibl1: with on:dicnd utility lines. c_ The trees m:1y be spre:1J ,11 lrn:gulnr inlr.:1·va!s in orJer to ?ccommod:ik sight distance requirements for dri1·cway~ and m1ersect10ns. 2. KCC 21 A. J 6.190 Fin all cial guarnntel.'s. Financial guarantees shall be rcqu1rc·d rnnsistem 11·ith the pro1·Jsi0ns of Title 27.\. Sigu_ilkrnt Tree 1:eci:nciuu-KCC 21A.33.230 wl1id1 ;1pplies 10 the sill:.<! detaile~ lice retr:i_iuon p!Jn shaJI_ be stibmitted wiLh the engine<::ring phns for (he s_ubJcct p_lat. fhi;: tr~·_c re[..:nt;on plan (and cngi111:,-rii1g plans) shall be cons1stc11l _ 11 1th :IJL' re~uir~in<:111~ of KCC 21 A.3~.1:1 (J, as well :i~ the eu:Jc'eptual tree r_eient~.011 plan _11 h1ch 1s p;irl of the hearing reco;·J for this projl'Cl. :,.:0 ekarm~ GI the s.ubJ<.'ctyrop_cny is permitted until tile liiial trei.: mention plan is :1pprovcd by Ll,SD. F1,1ggu1~ cind temporary frnemg ortrees to be ret;li:icc.J ~hall be proYidcd, consiste:1t with KCC 2lA.38.230D4. The placc:llent llf 1r1,pen·iot13 surfacoe:,, fill mat~rial, CXL'a1·ation \1·ork, or the stonHt\! of const1"L1ctioi1 rn~:ler"i.1!~ is prohibi:c·d _wii!iin the fcnceJ .:1-..:as arn_;;,d pre,cr1·,:J 1r..:es, except for gr,~drng 11·urk pamnted pursuant to KCC 2 !A.3S.230Ll-ld(.:') .-\ n?te sh nil be pbc<:d on the final plat mdicating th::t the tr<:es sho\1 n lO be reiarned 011 tlw u·cc rc1<cr1tirn1 plau ~h;i!I be 11iaintailied by :lie future 01111ers uf the proposed Jo;_c;, consistem wi:!1 KCC 21A.38.230G6. (Note that the tree 1·1.'k_r1tion plan ~_h:ill l1L' included :1s p.1rt of the final engi11ace 1·illg plans for tiic subJLTt plat.) l.L 1\<,'_JS._;1rc: no si,g;nlfl1·~rnt trees as d1.'f1J1.:d.l?1· the Spec i:1 l_(h-er lav D1,\r_i_s:_r_o11 the ~J!.k'..Jl1~·,1. this rfq\_ljJ•,!I_J'1ll.dOes i!QL~p;~):., -----~ The existir'.g !muse ,h.i:J. ~oe remo1 eJ or demolished J'I i or w 1he final approYal and reL·ordmg. A J"m0hc1011 µ~rm:! ,hall be obtained prior to demolition. Pro1·idc 35' 1x1ved radii at the intl'rsr:c1ion of 10611' Avenue SE anJ SE 172 Street per KCRS S~ction 2. lO. DedicJ.te a 25"foot propttty line radius at (lit; intern:ction of !06"' A.v,;nue SE and SE li2nJ Strc-et per KCRS Section 2.10. 8. H.o:id .\lirigacioa 1'.iymclit S: :,(~m C. D. Existing roadside obstacle(s) shall be n:Joc:iti:d to pro1·ide ,1 minimum clenr:mce of 10 fed from the edge of the trc\l·d hmc to !he obstudc(s) per KCRS Section 5.1 l _ E. l'ri\'ate c1cccss to Lots 2 ;rnd 3 sh:i!l be sho\\'ll LlS a joi1ll-11sc drivcway trnct per KCRS Section 3.0!. The tract slmll be an undil'ided 0\1·ncrship to tlie lots it S\.'r\'cs, and the lot 01,·nl'rs sliall be responsible for its m:li111enance. The tract shall be 20-feet wiJe with a 18-foot-wide p,11·ed surface. Tile tract :,hall be a rni11imulll Qf 20 feet in length. UTILITY CONFLICT NOTE: CAUTION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE @ 1-800-424-5555 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSING TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE NOT GUARANTEED AND ARE SUBJECT TO VARIATION. LEGAL DESCRIPTION LDT 13, BLOCK 4, AKER'S FARMS NO 5, ACCORDING TD THE PLAT THEREOF, RECORDED IN VOLUME 40 OF PLATS, PAGE 27, IN KING COUNTY, \./ASHINGTON, EXCEPT THE \./EST 170 FT. AS MEASURED ALONG THE NORTH LINE THEREOF; AND EXCEPT THE NORTH 60 FT. OF THE REMAINDER. 9. 10. Tlie Hpplicant shall comply wi1l1 Road Mitigation Payment Sys(em (MPS), by paying tht: n:quim.l /\!J'S fec as ddtrmined by King County Depart11icn( ofTransportution, plus an admini:.trati\·e fee. ThL· applicunt hrLS an uption to cillii.:r: A. Pay tli..: MPS foe at Ji11J] shoi1 subdl\·ision recording .ind the i\'lf'S .idministrntive fre :1t fo1:tl short subd1\·isiun application, or B Pay tht.> MPS fre at building perrnil issuance and 1Jie J\IJJS adrninistra1i1e fee at the time of building pe:nnit npplie:nion. If option A is chosi.:n, thc.·n tl1e following note sliall be sho>1 non the final sbort plat: .\JPS FEE \'OTJCE: All fees ri;quin:d by King County code 14.75, l'vlitigation Payment System (i'\'JPS) hnYe bw1 paid. If option Bis chos..:n. then chi.: following note shall lH: ,\bO\\"ll on the final sbort pbc: .\ll'S FEE NOTICE::: Tl1is short pl:it is subjec( to King County Code ;,,,To, J-1-.75, King County Rone.! /\1itig,1tion P:iy1111.·111 System (:llPS). The !VIPS foes 1i!us the \H'S adrniuistrali\"e fee s!iall be paid at tbl: time of building p<:1rnit application at the r.ite in eftCcr :Lt that time. Slate EuYirunruent:1! l'ulk.1· Ad (SEP.\) This short subdil'ision 11;1~ e;,.rn1pt from the pnl\"ision of the ~l::te Em·i1·onmental Policy ,\cl (Sl:.l'.-\). Other Consickrntious I'rclli:1inary ap;cro1·al of this application du~s not limit tbe aprlicant's responsibility to 0Lt;1in any reqtiired p,~rn1it or license from the State or other r~gul:-nory body .. This irny include obtaining a forest practice p~nnic from the: \Vasl1ington State Depa11111ent of '.'-,;awrnl Resources for tree rerno\'al. Co\JE.R J 2- 3 ..ci... I)R/\1t...11¥=E. ~ RoAb P/....1\N "!OTES 't DETl\ i LS TE.S.C P. TREE. PLAN l/1 NofS: U.S. P.S. UX:.f\11DW <91--1 fll.£. /\:, !<ING CouNJ't DDEs. VERTICAL DA TUM, NAD 83, PER \./SDOT GEOGRAPHICAL INFORMATIDN REPORT BENCHMARK> CONCRETE MONUMENT IN CASE \.II A BRASS PLUG~ THE INTERSECTION OF SR 515 & SE 180th ST. ELEVA TIDN = 402.09' PER \./SDOT GEOGRAPHICAL SERVICES SURVEY MARK REPORT, MONUMENT I.D: #2606 AND DESIGNATION #IS 1765. Vici n it y M o p t N Soils Mop -----·-·---- Site Pion Approval Approval of these plans is for construction of road and drainage irnprovements, site drainage & grading and temporary erosion control in unincorporated King County only. These plans do not authorize any other utility approval or improvements proposed in any State right of way. Si'e plan approval is void if the commercial building permit has not been obtained or renewed within two years of upprovo/. Subdivision pion approval is void if the final plat is not recorded prior to the preliminary plat approval expiration. 1iSSESSOR'S NO.: 008700-0280 Pf,O RATA SHARE ASSESSMENT ANALYSIS (County Use Only) Section Township Range Tax Parcel Number -~ WJJ I 0141 I o 10 I 8 17 I o 10 I I o 12 I 81 o I Site Location Is within the _ GR_EE~_BIVER drainage shed(s) Pro Rota Share Assessment(s) ore: D Required D Not Required from the site due to development for increased storm water runoff. P1~ok Runoff Assessment Rate(j ) per c,f.s. lncreoses.(10 year, 2 hour storm) P0.:0~,; Volume AssE!ssment Rote(:J ) per Ac. Ft. increases.(2 yeor, 2 hour storm) \ \ AGREEMENTS, PLAN REFEr,ENCES, PERMITS ETC. (To be completed by Consultant) Preliminary Plat Approval/Permit Issued Dole: MARCH 12, 2004 expiration Date: MARCH 12, 2009 Other Related Permit Numbers Received: Right-of-Way Use Permit • Grading 1 ! Bu ii ding/Structural ! Other Boord feet of tree removal on site: Cubic yards of material hauled on/off the site: i Is this a erosion sensitive area site? (Yes/No): NONE ND Nate: If "yes", a Highly Sensitive Site Erosion Control Supervisor is required. See ESC plan and TIR for details. L CJ 0 (/) z > L -(l) a: (l ::J ill (J) "-.. w L (l) z (l) C - Ql CJ C w z "-.. +' w <) (l) +' ·-a: ..r:: <) w L <( C, C Ql w ·-(/) (l) <( 0 J Q.) () (',j ii; ~ ,q 0 ...., co "i< 0:) 0 C\) . ,q ~ ..., :::l -0...., t:J:i q 0:) ~ ,., "i< 0:) ~ "' Ol 0 I 0 l{) 00 w a.: ci w (_') w <{ -, -; If) w :::, <{ -, (l) C 0 ..r:: 0... L 0 +' 0 C u L 0 0 u +' <) (l) ·~ 0 L 0... --~----------------------------------1 Ernergency 911 Pol ice-Fire-Rescue 1....---------·,-.--------------·-··-------·- Notice Required Contractors shall notify operators who maintain underground utility llnes ln the area of proposed excavation or blasting ot least two business days, but not more than ten worklng days prior to commencement of excavation or demolition in accordance with RCW Title 19. Names ond telephone numbers of the operators of underground utility lines in this project appear below. These numbers shall also be used to serve in an emergency conditions as required. Phone SOOS CREEK WATER & SEWER DIST. (253) 630-9900 Sanitary Sewer SOOS CREEK WATER & SEWER DIST. (253) 630-9900 Water District PUCET SOUND ENERGY ( 425) 454-6363 Gas Company PUCET SOUND ENERGY (253) 395-6915 Power Company Call Before You Dig DIAL-A-DIG 1-800-424-5555 Notes 1. The Developer is required ta notify the Land Use Services Division, Lond Use Inspection Section (206) 296~6642, three days prior to the beginning of construction for a preconstruction conference and specifically request inspection before beginning: A. Installing siltation and erosion control measures B. Cleoring and grubbing C. Earthwork D. Installation of ony underground utllity E. Before placing subbase, base or paving surfaces F. Installation of any forms or placing any concrete 2. A permit must be obtained from the office of the Resident Englneer, Washington State Department of Transportotion, before oriy construction is started on any existing state route. 3. A Hydraulic Project Approval (HPA) Permit must be obtained from ~he Washington State DepCJrtment of Fisheries prior to any work when required. 1----------------·-------------------------1 Bonding Information Restoration Bond Amount $ -------- Performance Bond Amount $ -------- RECOMMENDED FOR APPROVAL (To be completed by King County) Date Engineer Pion Reviewer Engineer Supervisor Traffic & Planning Engineer Sensitive Areas Structural Review Engineer Other i\1-PPROVED FOR CONSTRUCTION DEPARTMENT OF DEVELOPMENT & ENVIRONMENTAL SERVICES \ ioate ~ ~15 ·->, ~ Q) L <l) <l) C L L (J> ~\> V:J1,..C ()(f)oW D King County, Washington James H. Sanders, P.E. Development Engineer PROJECT CONTACT INFORMATION ___ H_A_M_I_N_II_C_H_A_U __ _,( 425) 643-3993 Name 4101 150th AVE. SE Phone BELLEVUE, WA. 98006 Address and Zip Code D A Partnership :gJ An Individual ___ l:_IA_k_I_IN_H __ C_H_A_U __ __._( 425) 643-3993 Name 4101 150th AVE. SE 98006 BELLEVUE. WA. Address and Zip Code Phone D A Corporation D A Partnership 13 An Individual _J_A=E=-G_E='R.c._E_,N'-'-G""'IN:.c=E=E.::c'R""IN=-·..:cc _ __...:( 253) 850-0934 Name Phone 94·19 S. 204 PL .. KENT 98031 Address and Zip Code (\] (\) ~ 0 ,., ~ 0 0 ~ ., r--0 (J) () ...;i O'.'. -w m . 2 L L 0 (lJ (l) z :=i .0 .0 z E E +' C w :J ::J (l) _J z z E LL >, +' 0. _µ <) 0 (J) > (l) - w ·-·~ (l) 0 +' 0 > <) L (l) 0 <( Q_ 0 License /Seal ........ ;. -. x.,S J.Jl1vJ )'?-~~ of :J:«_~4'o Q 1 t?\ X nk\ ll . ~, ' l\:~1&~ 34 $: 6\ '( <'ssftGis,<SC~, ,\ ~ ">J\v EXPIRES: 3/1/2010 I Sheet 1 of 4 ~- L~l I ti @ [lit __:.J ~ ~ ~ C w ,;:,, .... d = ,- r~ &°) cl ~ > 0 D !l'!!J! :z ~ @s Ii I ------------~--"----1 .--------........ ------------------------------------------------------------~-----------------------------'""-------------,----------------....... -~R-EVl_S_IO-N-S:--, I A PORTION C)F THE SW 1 /4 OF SECTION 29, TWP. 23 N., F<GE. 4 E., W.M. 1+00 10+00 SCALE: 1" -20' HORZ. 1" 5' VERT. SCALE: 1" 1 " VARIES I 5' SIDEWALK 20' HORZ. 5' VERT. 30' SE 2+00 172nd ST. (URBAN SUB ACCESS) 11+00 106th AVE. SE (URBAN SUB ACCESS) (L 0 12· w SAW CUT I-z w ::,: ~ <( (L 8-' I VARICS 3c " n:: 8-' i--V_A_Rl~Es_±_7--.5_'c-'(_10:..:6 __ th_,)+-.... µ INSIDE EX PVMT. (1 o_6th) 4' (172nd) I 4· INSIDE E . PVMT. (17 nd) 0.5' 3+00 STREET TREE (TYP) -WESTERN LARCH (LARIX OCCIDENT ALIS) PLAN TED------..__,, 5' FROM R.O.W. LINE (4 TREES) ', ",, .. , ,], 1,,1 ~./~2~-~0%f,~===~!lr'Hi~@~~N/E~X;IS~Ti~G~P~A~V~EM~E~NgTA\lI,l2¥£nd) ,,i, .. \~-----:"c....(··· EX1ST1NG.LWvtTki1ftfe61 h) 5" (_ 1/4" EDGED 2% /" 11 GROOVE /"R\ -2.0% El ' ' .. ,' ' ""\'+· ri;'.°" 4" THICK CONC. WALK VERTICAL CONG. CURB & GUTTER CROSS SECTION SE 172nd ST. & 106th AVE (URBAN SUB ACCESS) N.T.S. 2" CLASS "B" ASPHALT CONCRETE 1.5" COMPACTED DEPTH CRUSHED SURFACING TOP COURSE -5" COMPACTED DEPTH ,',Ff\ CRUSHED SURFACING BASE COUSE -ADDITIONAL GRAVEL MAY BE REQUIRED DEPENDING ON SOIL CONDITIONS ' ' 5.0% -;~:!.-'I.._ . ' ' ', • r T ,. ' '' ' ' ' ' . *NOTE.· TOP OF CURB @ DRIVEWAYS CEMENT CONCRETE VERTICAL CURB AND GUTTER NOT TO SCALE NOTE: PER KCRS SECTION 4.1 OF, A 1 INCH FULL WIDTH OVERLAY SHALL BE REQUIRED ALONG THE PROPERTY FRONTAGE OF 106th AVE. SE AND SE 172nd ST. APPROPRIATE REPAIRS TO THE EXISTING SUBGRADE, BASE MATERIAL, SU.RFACING AND PRE-LEVEL MAY BE REQUIRED PRIOR TO PLACING THE OVERLAY. THE OVERLAY MAY BE WAIVED ONLY UPON WRITTEN REQUEST AND AFTER AN EVALUATION OF PAVEMENT CONDITIONS AND /OR CHANNELIZATION REQUIREMENTS HAS BEEN COMPLETED BY THE COUNTY ROAD ENGINEER OR DEVELOPMENT ENGINEER. NOTE: BLOCK 4 AKER 1 S F Ar~MS I\JD. 5 VOL 40, PAGE 27 LDT 12 130.01' 1. TRACT "A' IS A JOINT USE DRIVEWAY TRACT TO BE JOINTLY OWNED AND MAINTAINED BY LOTS #2 AND #3 . FLOW LINE TO BE DIRECTED TO CATCH BASIN AS SHOWN ON PLAN w 20' w z -~----··---+--------~-·----z ~ TRACT ~ ~ ~ 3 g 1'1 18' 1' A.C. PAVEMENT ------• THICKENED ! 3_'_ 1 EDGE CURB ',':-.1-----. -1 I ___ ._J_1, 2% -c::s:-=s::_'-_ -s;:-·r11,::-.1//;'0///.;;;·/// 11/.."::'Pl(c-ll/://,' IV--~~""3~~__::s::::~:S:::::c=:" ~ · . . ~;,: "" ,, J~i\~f 1~~~;:;:,'" 2+62.28 2· l T \_ 1 1/2" MIN. COMPACTED DEPTH CRUSHED SURFACING TOP COURSE \__ 2 1/2" MIN. COMPACTED DEPTH CRUSHED SURFACING BASE COURSE ADDITIONAL TREATMENT MAY BE REQUIRED DEPENDING m, SOIL CONDITIONS. SEE SEC. 4.02 _,J_QJNT U$E DRIVEWA '(_JB_ACL __ _ N.T.S. J' 2" ASPHALT CONG. PA l;[M£NT THICKENED EDGE ASPf-fAL T DETAIL LDT 13 SIDEWALK TRANSITION RAMP (DETAIL SHT. 3) NOT TO SCALE END CURB, GUTTER & SIDEWALK King County Department of Development and Environmental Services APPROVAL FOR SITE CONSTRUCTION Fieview Engineer ENGRCOMP Date 2. EXISTING WATER MAIN SHALL BE LOCATED BY POTHOLING PRIOR TO INSTALLATION OF DRAINAGE SYSTEM. GRAPHIC SCALE Senior Engineer ENGRCOMP Date 20 O 10 20 40 ~ ~r-t ~· ~,::, ±v:nrrm· 1 ( IN FEET ) 1 inch = 20 ft. 80 '1"Wli!WTT1'7777Wl~ DEVELOPMENT ENGINEER Comments: APPROVAL Date . r;.EV. PER CTY. -cm.1MENTS 10-1-0 1. r;EV. PER CTY. COMMENTS 10-20-08 E-t ~ ~ ~ ~ Q ~ ~ ti:: "'1 C/j :B P.. E-,.; 'O ~ 0 Q -. "'1 ~ '1< t5 C") 0 :'1 C'J r.... ~ -. ::::, ~ ~ ,:.: u (.) w ~ 0 0: Q_ C") ~ 'O ~ ~ c:, 0, ~ c:, ~ ~~~ "'1 :"l 'O ~ .:::i ;!:::;--.. ...., lQ 0 -<;\! ~ ~~~ "1 . --i .....:i ...._o ~ c:, N ,..-:; :;~~ ,:.: z < 0 ::, Q_ Q_ < DATE: 3/16/07 SCALE: 1" = 30' DESIGN BY: JJJ DRWN. BY: JJJ APP. BY: FILE No. SHEET 2 OF 4 GENErtAL NOTES 1. All 0 1inst1uction shall be in accordance with the King County Code (KCC), Road Standards (KCRS), and the King county Council's conditions of preliminary subdivision approval. It shall be the sole responsibility of the applicant and the prufessional civil engineer to correct any error, omission, or variation from the above requirements found in these plans. All corrections shall be at no additional cost or liability to King County. 2. The design elements within these plans have been reviewed according to the King County Department of Development and Environmental Services (ODES) Engineering Review checklist. Some elements may have been overlooked or missed by the DOES plan reviewer. Any variance from adopted standards is not allowed unless specifically approved by King County prior to construction. 3. Approval of this road, grading, and drainage plan does not constitute an approval of any other construction (e.g. domestic water conveyance, sewer conveyance, gas, electrical, etc.) 4. Before any construction or development activity, a pre-construction meeting must be held between the DDES's Development Inspection Unit, the Applicant. and the Applicant's Construction Representative. 5. A copy of these approved plans must be on the job site whenever construction is in progress. 6. Construction noise shall be limited as per King County Code (Section 12.88); normally, this is 7 a.m. to 10 p.m. weekdays and 9 a.m. to 10 p.m. on weekends. 7. It shall be the applicant's/contractor's responsibility to obtain all construction easements necessary before initiating off-site work within the road rights-of-way. 8. Franchised utilities or other installations that are not shown on these approved plans shall not be constructed unless an approved set of plans that meet all requirements of KCRS Chapter 8 are submitted to the DDES's Development Inspection Unit three days prior to construction. 9. Datwn shall be KCAS unless otherwise approved by DOES. 10. Groundwater system construction shall be within a right-of-way or appropriate drainage easement, but not underneath the roadway section. All groundwater systems must be constructed in accordance with Section B1 3.02 of the APWA Standard Specifications. 11. All utility trenches shall be back filled and compacted to 95 percent density. 12. All roadway subgrade shall be back filled and compacted to 95 percent density (WSDOT 2-06.3). 13. Open cutting of existing roadways is not allowed unless specifically approved by DOES and noted on these approved plans. Any open cut shall be restored in accordance wtth KCRS 8.03(8)3. 14. The Contractor shall be responsible for providing adequate safeguards, safety devices, protective equipment, flaggers, and any other needed actions to protect the life, health, and safety of the public, and to protect property in connection with the performance of work covered by the contractor. Any work within the traveled right-of-way that may interrupt normal traffic flow shall require at least one flagger for each lane of traffic affected. All sections of the WSDOT Standard Specifications 1-07.23 • Traffic Control, shall apply. DRAINAG~ NOTES 1. Proof of liability insurance shall be submitted to ODES prior to the pre-construction meeting (KCC 9.04.100.0). 2. All pipe .ind appurtenances shall be laid on a properly prepared foundation in accordance with WSDOT 7-02.3(1). This shall indL!de leveling and cor'npacting the trench bottom, the top of the foundation material, and any required pipe bedding, to a uniform grade so that the entire pipe is supported !JY a uniformly dense unyielding base. 3. Steel pipG shall be galvanized and have asphalt treatment #1 or better inside and outside (KCRS 7.03). 4. Alt drairiJge structures, such as catch basins and manholes, not located within a traveled roadway or sidewalk, shall have solid locking lids. All drainage structures associated with a permanent retention/detention facility shall have solid locking lids (KCRS 7.05). 5. All catch basin grates shall conform to KCRS drawing numbers 2-013, 2-018, 2-019, or 2-020, which includes the stamping "OUTFALL TO STREAM, DUMP NO POLLUTANTS" and "Property of King County" (KCRS 7.05). 6. All driVlll/'lay culverts located within King County right-of-way shall be of sufficient length lo provide a minimum 3:1 slope from the edge of the driveway to the bottom of the ditch. Culverts shall have beveled end sections to match the side slope (KCRS 7.03(L), Drawing No.2"001). 7. Rock for erosion protection of roadway ditches, where required, must be of sound quarry rock, placed lo a depth of 1 'oot, and must meet the following specifications: 4"-8" rock/40%-70% passing; 2''-4" ro<:k/30%-40% passing; and -2' rock/10%-20% passing. Installation Shall be in accordanco with KCRS 7.02(6) drawing number 2-024. 8. Drainagu outlets (stub-outs) shall be provided for each individual lot, except for those lots approved for infiltration by King County. Stub-outs shall conform to the following: a) Each olitlet shall be suitably located at the lowest elevation on the lot so as to service all future roof downspouts and footing drains, drivewciys, yard drains, and any other surface or subsurface drains necessctry to render the Jots suitable for their intended use. Each outlet shall have free-flowing, positive drainage to an approved storm water conveyance system or to an approved outfall location. CURB Til.PER s -.0'· DRIVEWAY CURB CUT (SEE SEC. FiG 3-012) 3/8"" EXPAW:CON ~IO!NT (TY?.) ® DETECfA.OLE wNm11\JG PATTERN (SCE DETAIL) ··· SIOEl/iALK MIN. ' CUl~B, OR CURB A,~D CUTTEil ': ! ' ---·· CROSSWALK CURB RAMP 1 A i,I) COIIENT CONC. '.)::JEW,..i.LK R/l.1\.H_;, r'i'P::: 1A DETECTABLE WARNING PATIERN AREA SHALL BE A YELLOW, IN COMPLIANCE i . B . WITH STD. SPEC. 8-14.3(3)---.. ,-' t...JIN. filAX A 1 -5/8" 2 3/8"' 8 . 5/8' .. 1 i/2·· C. 7 /i6"" 3/<,"" D 7/8" 1 7/113· .,, '@·@ A .I -'"' '"' ' PLAN ·'"" __ c ELEVATION NOTES: 1. SEE SEC. 3.04 K.C.R.S. FOR JOINT REQUIREMENTS. 2. ROLL GUTIER TO MATCH POSITIVE SUPERELEVATION. 3. SEE ORAWING NO. 1-006 FOR CONFIGURATION OF FILL & WALKWAY BEHIND CURB IF REQUIRED, 4. FOR INTEGRAL POUR CONSTRUCTION, 1/4" EDGED GROOVE MAY REPLACE EXPANSION JOINT AT INTERFACE BETWEEN THE CURB ANO ADJACENT SIDEWALK. 5. SEE SEC. 3.03 FOR EXTRUDED CURB ANCHORAGE. SiDEWAL'r\ 6'" 1/ARIC:S s· VAR;C:S RIGHT ···C,:: -VVX{ LIN[ ;~ l . -0.02 n ./F1: • ... . 1-::-..._v;s._V-:!(-/" SECTI01~ A-A C£11.:J·JT COi'iCRi::TC: ORIVt:WAY 5" THICK 9'-0" ? 16" 2'-7" 5'-0" --'-''--I---" ------~--------< -(ANCHOR BOLT PA !TERN PER NDCBU PEDESTAL TEMPLATE 1 -11 3/8" x FULL DEPTH -:---6"r 1 ~ ! 1 EXPANS10N JOINT S~:CJ. -~~ D ~. ,•. ' ' -•.•• i:o ,I -10'-o" '------------1 10'-o" f-----------, ?--t------------~--,-~--~----l. 2·-0:-~- 1---1 ~ SID£ VIEW i 2' o" I t------ ' I ' C) ,I Lr) N.D.C.B.U. I ~ I ~---~-- b) outlets on each lot shall be located with a five~foot~high, 2" x 4" stake marked "storm" or "drain". The stub-out shall extend above surface level, be visible, w1d be secured to the stake. PLAN I.A YOUT 1 DETECTABLE WARNING PATTERN DETAI!,_ 6" c) Pipe rnc.1terial shall conform to under drain specifications described in KCRS 7.04 and, if non-metallic, the pipe shall contain wire or other acceptablE! detection. d} Orainagtt easements are required for drainage systems designed to convey flows through individual lots. e) The applicant/contractor is responsible for coordinating the locations of all stub-out conveyance lines with respect to the utilities (e.g. power, gas, telephone, television). · f) All indiviciual stub-outs shall be privately owned and maintained by the lot homeowner FIR~ HYDRANT OR UTILITY POLE LUMINAIRE 15' MIN. 1~1~ 0 Ml • <i: PLANTING STRIP ~ ~~ "' 0 SIDEWALK NEXT TO VERTICAL CURB 50' MIN 50' MIN NOTES 1. PLACEMENT OF GRATINGS, ACCESS COVERS AND OTHER APPURTENANCES SHALL NOT BE LOCATED ON CURB RAMPS, LANDINGS AND GUTIERS WITHIN THE PEDESTRL'IN ACCESS ROUTE. 12) RAMPS SHALL BE TEXTURED USING TRUNCATED DOME PATIERN (SEE DETAIL THIS PAGE). DETECTABLE WARNING PATIERN SHALL BE YELLOW IN COMPLIANCE WITH WSOOT STANDARD SPECIFICATION 6-14.3(3) 3. RAMP CENTER LINE SHALL BE PERPENDICULAR TO OR RADIAL TO CURB RETURNS UNLESS OTHERWISE APPROVED BY THE COUNTY ROAD ENGINEER. 4. RAMPS SHALL BE CONSTRUCTED AT CORRESPONDING SIDEWALK LOCATIONS ON OPPOSITE SIDE OF STREETS WHEN RAMPS ARE CONSTRUCTED ON ONE SIDE OF STREET, SEE FIG. 3-010. @ LANDING SHALL BE MINIMUM 4 X 4'. @ CURB RAMP 1A MUST BE INSTALLED UNLESS OTHERWISE APPROVED. 7. SEE FIGURE 3-001 FOR CURB AND SIDEWALK JOINT PLACEMENT. 1 . HANDICAP RAMP STREET TREE NOTES: TREES SHALL GENERALLY BE PLANTED BACK OF THE SIDEWALK. PLANTING STRIPS WILL BE APPROVED ONLY AS PART OF A LANDSCAPING PLAN IN WHICH PLANT MAINTENANCE, COMPATIBILITY WITH UTILITIES, AND TRAFFIC SAFETY ARE DULY CONSIDERED. NOTE 1.--'-__,, VERTICAL CURB LINE STREET TREE NOTES: STREET TREE 1. TREES TO BE PLANTED AT APPROX. 40' ON CENTER, WITH ADJUSTMENTS FOR UTILITY FIXTURES AND MAILBOXES. 2. HOMEOWNERS SHALL BE RESPONSIBLE FOR TREE MAINTENANCE FOR TREES WITHIN OR ABUTTING LOTS. 3. STREET TREES SHALL BE: 1.-M'-.lX DC0l~/',L..\:5 ( \J.I cSfE.R.t--1 Lf,,RC/-1) LOCATE 5' BEHIND THE SIDEWALK (OR CURB, IF NO SIDEWALK) Ar INTERSECTION 2. STANDARDS 3. IF PLANTING STRIPS ARE APPROVED: A. MIN. DISTANCE FROM CENTER OF ANY TREE TO NEAREST EDGE OF VERTICAL CURB SHALL BE 4 FEET. 8. TREES SHALL BE STAKED IN A MANNER NOT TO OBSTRUCT SIDEWALK TRAFFIC. C. IN CASE OF BLOCK-OUTS, MIN. CLEAR SIDEWALK WIDTH SHALL BE 5 FEET IN RESIDENTIAL OR 8 FEET IN BUSINESS DISTRICTS. ON BUS ROUTES, PLANS SHALL BE COORDINATED WITH METRO SERVICE PLANNING. PHONE 684-1622. TRENCH X·SECT/ON NTS FACE OF VERTICAL CURB PLAN VIEW NEIGHBORHOOD DELIVERY &: COLLECnoN BOX UNIT (f::l,Q, C,B..U,) INSTAlLA 770N. NOT TO SCIILE slope ---- small catch basin or 1•ard drain l 5700 sq. ft. >700 sq. ft. PLAN VIEW OF ROOF NTS - w - Type I -L- ~ 2' X 10' level trenches CB standard dispersion trench I w/ nolched grade board ength 10' per 700 sq. ft. of roof area, s ee Figure 4.2.2.C al the Surface Water Design Manual INDIV. LOT DOWNSPOUT DISPERSAL TRENCI-1 -----------------~ CEMENT CONCRETE SIDEWALK AND RAMP NOTES .\J' MIN. SECTiON A-A 1. SEE SEC. 3.02 FOR SIDEWALK WIDTHS. MATCH EXISTING OR PROPOSED SUF<FACE ------~ 2. SEE SECS. 2.02 AND 2.03 FOR PAVEMENT AND SHOULDER WIDTHS. 3. SHOULDER SHALL BE SURFACED AS CsEQUIRED BY SECS. 3.07 ANO 4.01. PAVED SHOULDEF, SL.OPE SHALL lvlATCH CROWN SLOPE OR 0.02 FT/FT. 4. SEE FIG. 3-001 FOi< CURB AND SIDEWALK JOINTS. (") RAMP SHALL BE TEXTUF,ED USING TRUNCATED DOME PAHEF,N. (SEE FIG. 3-01 DETECTABLE WEARING PATTERN SHALL BE YELLOW IN COMPLIANCE WITH WSDOT STANDARD SPECIFICATIONS 8-14.3(3) 6. THIS DETAIL APPLIES TO ROLLED AND VERTICAL CURB ROADWAYS. SIDEYf ALK TRANSITION RAMP NOC.BU. CUTLER MODEL CB-6 OR EQUAL~ --·--j r: r· ~i I . ' • ' ~ -l--- ,.., I ' .,,. ~ Lr) ,,.., I ,_ 0) ! ) . !L: .. l •. ::J . . ,. .. . . . ' .. I . 1 ·-6·: I FRONT VIEW . ko -<; ~ t3 Ct.; r.t:i >ti • ~ . King County ~ Department of Development <Jnd Environmental Services -· APPROVAL FOR SITE CONSTRUCTION Review Engineer ENGRCOMP Date Senior Engineer ENGRCOMP Date DEVELOPMENT ENGINEER APPROVAL Date Comm en ts: - REVISIONS: REY. PER CTY. OMMOOsTo-1-0· (j z (t w w z (' z w (t w (j w ~<( z ·PzJ "\ C>::_--::o E""l j Cl.a ~ ti ~ 'fl f'<i ~ ~ ::,.: 0-. "st: ~ ::S E~ <o ~ 0 C '-< ~ 'Sf< ~ (';) 0 1-, ~ 1:-,. ~ ,.... ~ ~ ,:.: c.) l) lW -, 0 "' CL "? :::, <o°' F;J O 0, ~ 0 ('? ~ • co cl,; \,.) §:1 0, 'Sf< "st: • <o ~ ~ i,:::-, ::S It) 0 • C\) f<1 ..... ~ ~~---><1 • -. ~~o ~ 0 ,< ;: ifl tri .i., ,:.: z "" () :::, "-CL "" DATE: 3/16/07 SCALE: 1" = 30' DESIGN BY: _ _ll.J__ DRWN. BY: JJJ APP. BY: FILE No. SHEET 3 OF 1 ! l I i I ' 1 I I ' rt· r , rii I '' '' EROSION AND SEDIMENTATION CONTROL NOTES 1. Approval of tliis erosion and sedimentation control (ESC) plan does not constitute an approval of permanenl road or drainage desi9n (e.g. size and location of roads, pipes, restrictors, channels, retention facilities, utilities, etc.). 2. The implemen talion of these ESC plans and the construction, maintenance, replacement, and upgrading of lhese ESC facilities is the responsibility of the applicant/ESC supervisor until all construction is approved. 3. The boundari~s of the clearing limits shown on this plan shall be clearly flagged by a continuous length of survey tape (or fencing, if required) prior to construction. During the construction period, no disturbance beyond the clearing limits shall be permitted. The clearing limits shall be maintained by the opplicant/ESC supervisor for the duration of construction. 4. The ESC facilities shown on this pion must be constructed prior to or in conjunction with all clearing and grading so as to ensure that the transport of sediment to surface waters, drainage systems, and adjacent properties is minimized. 5. The ESC facilities shown on this pion ore the m1n1mum requirements for anticipated site conditions. During the construction period, these ESC facilities shall be upgraded as needed for unexpected storm events and modified to account for changing site conditions (e.g. additional sump pumps, relocation of ditches and silt fences, etc.). 6. The ESC facilities shall be inspected doily by the opplicant/ESC supervisor and maintained to ensure continued proper functioning. Written records shall be kept of weekly reviews of the ESC facilities during the wet season (Oct. 1 to April 30) and of monthly reviews during the dry season (May 1 to Sept. 3D). 7. Any areas of exposed soils, including roadway embankments, that will not be disturbed for two days durin9 the season or seven days during the dry season shall be immediately stabilized with the approved ESC methods \e.g., seeding. mulching, plastic covering, etc.). wet 8. Any area needing ESC measures, not requiring immediate attention, shall be addressed within fifteen (15) days. 9. The ESC facilities on inactive sites shall be inspected and maintained a minimum of once a month or within 48 hours following a storm event. 1 O. At no time shall more than one (1) foot basins and conveyance lines shall be cleaned water into the downstream system. of sediment be allowed to accumulate within o catch basin. All catch prior to paving. The cleaning operation shall not flush sediment-laden 11. Stabilized construction entrances and roads shall be installed at the beginning of construction and maintained for the duration of the project. Additional measures, such as wash pads, may be required to ensure that all paved areas are kept clean for the duration of the project. 12. Any permanent flow control facility used as a temporary settling basin shall be modified with the necessary erosion control measures and shall provide adequate storage capacity. If the facility is to function ultimately as an infiltration systern, the temporary facility must be graded so that the bottom and sides ore at least three feet above the final grade of the permanent facility. 13. \'mere straw mulch for temporary erosion control is required, it shall be applied at a minimum thickness of 2 to 3 inches. 14. Prior to the beginning of the wet season (Oct. 1), all disturbed areas shall be reviewed to identify which ones can be seeded in preparation for the winter rains. Disturbed areas shall be seeded within one week of the beginning of the wet season. A sketch map of those areas to be seeded and those areas to remain uncovered shall be submitted to the DDES inupector. The DDES inspector con require seeding of additional areas in order to protect surface waters, adjacent properties, or drainage facilities. CATCH El_i'\SIN INSERT MAINTENANCE STA~IDARDS 1. /\NY ACCUMULATED SED!MENT ON Ofi AF!OUND THE F.ILTER FABRIC PROTECTION SHALL BE REMOVED ltvlMEDIA TEL Y. SC:DllvlENT SHALL NOT BE REMOVED WITH WA TEF( A~ID l1LL SEDl/v1ENT lvlUST BF OF AS FILL ON SITE OR HAULED OFF SITE. - DISPOSED 2 ANY SEDIMENT IN THE CATCH 8AS1~1 INSERT SHAI_L BE REMOVED WHE,', THE SEDIMENT HAS FILLED ONE-THIRD OF THE AVAILAcllE STORAGE. THE FILTER lvlEDIA FOR THE INSERT SHALL. BE CLEANED OR REPLACED AT LEAST MO~ITHL Y 3. REGULAR MAINTEl~ANCE IS CRITICAi_ FOR BOTH FOF,~lS OF CATCH BASINS PROTECTION UNLIKE MANY FORlvlS OF PROTECTION THAT GRADUALLY, CATCH BASIN PROTECTION V•/IU_ FAIi_ SUDDENLY AND COMPLETELY IF NOT MAINTAINED PROPERLY. FAI'_ / --ST/\NDAF\D STRE:\JCTH FILTER FABRIC CATCH NOTE: ONLY TO BE USED WHERE PONDING OF WATER ABOVE THE CATCH BASIN WILL NOT CAUSE TRl',FFIC PROBLEMS AND WHERE OVERFLOW WILL NOH F,ESIJL T IN EF,OSION OF SLOPES. 6ASl1'~ BASIN INLET FILTER A PORTION OF THE SW 1/4 OF SECTION 29, TWP. 23 N., RGE. 4 E., W.M. EX1SSMl=I RH1=383,o'\ 's STREET TREE -WESTERN LARCH (LARIX OCCIDENTALIS) PLANTE~, 5' FROM R.O. W. Ll~IE ( 4 TREES) " TEMP. CB INLET PROTECTION FILTER 'SOCKS'. ON EXfS'ffNC, CATCH BASINS. (SEE DET.l @ LEGEND CL£ARING LIMITS T£MP CB FIL T£R PRDPDS£D CDNTDUR E:XIST TR£€ EXIST. TREE TD BE REMOVED <'f!!l. C:3) 1 0 " Prf,. PINES EX. 12' CCP INV=381.5 BLOCK 4 AKER'S FARMS ND. \/DL 40, PAGE 5 27 LDT 12 CONST'R[JCJ'ION SEQUENC'E 1. Arrange and attend a preconstruction meeting with King County DOES Inspections Unit. Call (206) 296-6642. 2. Flag clearing limits and easements. Flag property lines. 3. Post sign with name and phone number of ESC supervisor. 4. Flag all trees that to be saved. 5. Grade and install quarry spall construction entrance. 6. Install silt fencing as shown on the plans. 7. Maintain erosion control measures in accordance with King County standards and manufacturer's recommendations. 8. Relocate surface water controls or erosion control measures, or install new measures so that as site conditions change the erosion and sediment control is always in accordance with the King County Erosion and Sediment Control Standards. 9. Cover all areas that will be unworked for more than seven days during the dry season or two days during the wet season with straw, wood fiber mulch, compost, plastic sheeting or equivalent. 10. Stabilize all areas within seven days of reaching final grade. 11. Seed or sod any areas to remain unworked for more than 30 days. 300,01' CCALC) 12. Upon completion of the project, stabilize all disturbed areas and remove BMPs upon approval of the Inspector. 130.01' GRAPHIC SCALE { IN YEE'f ) 1 inch = 20 ft. CX) (1.J (J\ LDT 13 Is i---- .. . . _J I I I EX HOUSE I I L ---- STREET TREE -WESTERN LARCH (LARIX OCCIDENTALIS) PLANTED 5' INSIDE OF R.O.W. LINE (4 TREES) King County Department of Development and Environmental Services APPROVAL FOR SITE CONSTRUCTION . Review Engineer ENGRCOMP Date Senior Engineer ENGRCOMP Date DEVELOPMtNT UJGINEER APPROVAL Date Cornments: REVISIONS: I. REV. PER CTY. OMMENTS 10-1-0- 1-------~ "' () w , 0 "' a. () z er w w z () z w h ~ h ~ ~ C) . ~~ V') .q ..., ~ ~ <::::, 0 -. ~ .,,. ~ c::, Cl') 1:-,.. -. b ~ u ~ c3 ~ 2; a I:..) . ~ Clj «! 2:; 0 >-,; er.; 0 ~ e; ~ C o-; DATE: 3/16/07 SCALE: 1" = 30' DESIGN BY: JJJ ORWN. BY: JJJ APP. BY: FILE No. SHEET 4 ~ 8' ~Plum '---------------------------------------------------------------------~R~E~~~IO~V~E:_ _______________________________________ ~----~=====·---·--------·--.L------....1 N.T.S. OF :1 I '. I --- ·' '· • ... 1-1/2'-J/4' WASHED ROCK TRENCH CROSS-SECTION SLOP£-~ PLAN 14EW OF ROOF TO ROAD DRAINAGE SYSTEM 2' X 10' LEvEL TRENCH WTTH PERFORATED PIP[ TYP. LOT PERFORATED STUB-OUT CONNECTION NO SCALE NOTE, EACH LDT SHALL INCLUDE A PERFORATED STUB OUT DRAINACiE CONNECTION TO THE STREET DRAINAGE SYSTEM, VARIES i ---------'.-----1· ,_: 2 > Cl. X Lu 0' 8.51 k' 12' ._..---------1--~~-i f..o---------=--1---------i 8'l9.5' SIDEWALK 0.5' --2% ',_ 4" THICK CONC. WALK VERTICAL CONG.~ CURB & GUTTER 2.5'-4' -- TYP Cli:OSS SECTION I SAW CUT MIN. 12" INTO EXIST.: Pl/MT. I !"'-EXISTING PAVEMENT I 2" CLASS "l" ASPHALT CONCRETE 1.5" COMPA TED DEf:'TH CRUSHED S RF ACING TOP COURSE 5" COMPACftD DEPTH CRUSHED S~RF ACING BASE COUSE ADDITIONAL gr,AVEL MAY BE REQUIRED DEPENDING IN SOIL CONDITIONS I 106 AVE ~,E. & SE. 172 ST (URBAN SUB AGCESS) I ' N.T.S. TRACT 'A', JOINT USE DRIVE\./ A Y TRACT FOR LOTS 2 AND 3 ®---· A PORTION OF THE SW 1/4 OF SE1CTION 29, TWP. 23 N., AGE. 4 E., W.M. SSMH RIM=376,5 ~-+--TEMP, SITE BENCHMARK, RIM OF SAN SE\./ER MAN HOLE, ELEV, 383,0 TEMP. SITE BENCHMARK: RIM OF, SAN SE\./ER MAN HOLE: ELEV: 375.8 130,01' NOTES: 1. PUBLIC STREET tONTAGE IMPROVEMENTS: 12' TD FACE OF CURB SHALL BEi MEASURED FROM THE CENTERLINE OF THE EXISTING PAVN ENT, · 2, END NE\J CURB, GUTTER & SIDE\JALK AT THE \JEST EXTENSION OF LDT #1 ALONG SE 172 ST, 3, TRACT "A" SHAL~ BE A JOINT. USE DRIVE\J AY TRACT FDR THE BENEFIT I F LOTS #2 AND #3, · 4, ALL LOTS SHAL UTILIZE A PERFORATED STUB-OUT DO\JNSPDUT DRAIN~GE CONNECTION TD THE STREET DRAINAGE SYSTEM, BLOCK 4 AKER'S F ARNS ND. 5 VOL 40, PAGE 27 LDT 12 --~- ,. ' . - LDT 13 20 0 12' RCP ~INV=390,3 SCALE IN FEET ) 1 i ch = 20 ft. ao RECEIVED JAN il U 2004 KING COUNTY LANO USE SERVICES L03S00I6 > (; ' ,_' :,-, .. , REY1SIO)tSi :.: . SCALE: 1" ~· 20': . ;-;, 0---'--------. DESIGN BYi · JJJ -. DR\\N, BY: J .Of ··~-·· ' . \ ·.) ' .. ' ' ! :. '. l i I I ···.,i.·i·:b.·· ''.:"{) ~. I r I SHORT PLAT NO. ------ KING COUNTY, WASHINGTON N BASIS OF BEARINGS: HORIZONTAL DATUM = NAO 1983/91: THE EAST LINE OF THE N.E. 1/4 OF SECTION 29, TOWNS/-1/P 23 NORTH, RANGE 5 EAST, W.M., BEING S01'47'11"W PER KING COUNTY SURVEY CONTROL DATABASE COORDINATES BETWEEN MONUMENT POINT I.D. #2861 ANO #2867. LEGAL DESCRIPTION: (PER STATUTORY WARRANTY DEED UNDER REC. NO. 9711120779) LOT 13, BLOCK 4, AKER'S FARMS NO. 5, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 40 OF PLATS, PAGE 27, IN KING COUNTY, WASHINGTON; EXCEPT THE WEST (EAST, Sff NOTE 2 BELOW) 170 FffT AS MEASURED ALONG THE NORTH LINE THEREOF, AND EXCEPT TH[ NORTH 60 FEET OF TH[ REMAINDER. VERTIC.4L DATU1'l: NAVO 88, PER KING COUNTY SURVEY CONTROL DATABASE. BENCHMARK: CONCRETE MONUMENT IN CASE W/ A BRASS PLUG IN J" IRON PIPE LOCATEO @ Tl-/[ BACK OF CURB ON THE WEST SIDE OF THE INTERSECTION OF SR 515 & 108TH AVE. S.E. ELEVATION = 380.839 PER KING COUNTY SURVEY CONTROL DATABASE, POINT 1.0. #616'1, POINT NAME RENT1915, NAVO 88. 10" CONG. RET. WALL 12" RCP INV=378.4 ICING LOCATE'D OF SECTION 29, .30' I COUNTY S 1.fIOR'I' PLAT Ji'OR liA MlNH CHAU IN TliE' N.E1. 1./4, OF 'TliE' S'.1Y. 1 /4, TOWNSlflP 23 NOR'l'fl, !?.ANGE' 5 EAST, !(ING COUNTY, WASHINGTON BLOC!( 4 A!(ER'S FARMS NO. 5 VOL 40, PACE 27 LOT 12 W.M., RECORDING NO. VOL./PAGE SCALE: GRAPHIC SCALE 1" =30' 1 inch = 30 FT. 30 0 30 PORTION OF: N.E. 1 / 4, S.W. 1 / 4, SEC. 29, T. 23 NORTH, R. 5 EAST, W.M. KING COUNTY SURVEY~ CONTROL POINT I.D. #2861 i POINT NAME: 3789 X 3" BRASS DISK IN MONUMENT CASE i;\ N 170648. 966 (FT) . {J/1 I E 1305835. 695 (FT) , 'y c,.<:> I FOUND LARGE PK NAIL & WASHER WITH LS STAMP (UNREADABLE #) @ S.E. 1 70TH ST. ') C< ,,'<,, ,{1/ t/ -=r- ~ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 300.01' (CALC) 300' (PLAT) 130.01' -------------------------------- i1 "' I I HOUSE I 170 oo• ----------------- 1 ----· I 2" CONG. RET. WALL WITH WOOD FENCE -(WALL ON PROP. LN.) I I------W. LN. OF E. 1 70' AS MEASURED I ALONG N. LINE OF LOT 13 (W. 170' DEED) S. LN. OF N. I * WOOD FENCE INTERSECTION 0.3'± S. & 0.3'± E. OF PROP. COR. ~ ~ /_.'': HOUSE LOT 13 1 LOT 14 ~I g, <o "" vi' g:j ~ f-... I ~, ~ <o C\j s: ' --f-... I '0-I t; I (/J t I ':'.'.i CB o, @ SI1'E BENCHMARK(S): RIM=376.6 INV=374.6 N. 18" RCP INV=374.6 E. 12" RCP INV=J74.5 S. W. 12" RCP INV=389.6 KING COUNTY SURVEY CONTROL POINT 1.0. #2867 POINT NAME: 3796 TOP CENTER BOLT OF FIRE HYDRANT LOCATED @ THE N.E. QUADRANT OF INTERSECTION OF SE 172ND ST. & 106TH AVE. SE, ----------------------L----NAIL IN CONCRETE IN MONUMENT CASE ELEVATION = 382.22 RIM OF SANITARY snvrn MANHOLE LOCATED APPROX. 70' N.W. OF THE N.W. PROPERTY CORNER OF LOT 3, ELEVATION = 382.38 CONTOUR INTERVAL: 2 U.S. FEET FOUND CONCRETE FILLED J" IRON PIPE W/ NAIL IN MONUMENT CASE@ P.C. LEGEND: @ • CONCRETE MONUMENT IN CASE AS DESCRIBED S[T 1/2" REBAR & CAP "LS 37540" :n: A ~ FOUND PK NAIL AS O[SCRIBEO FIRE HYDRANT BOLLARD ~ WATER METER a, WATER VALVE §! CATCH BASIN @ SANITARY SEWER MANHOLE :Q= UTILITY POL[ --::l GUY ANCHOR § MAIL BOX * CONIFEROUS TRff TBM: S.E'. 172ND ST. 661.43' (CALC) 661.~' (PLAT) ----S87\59'28"W 719.93' (MEAS) TOP CENTER BOLT FIi<[ HYDRANT, EL = 382.22 SURVEYOR'S CERTIFICATE THIS MAP CORRECTLY REPRESENTS A SURVEY MADE BY ME OR UNDER MY DIRECTION IN CONFORMANCE WITH THE REQUIREMENTS OF THE SUfNEY RECORDING ACT AT THE REQUEST OF HA MINH CHAU IN Jan. 2004 __llr4i,1yff: OJf,,__ {9r± r.Cs.Dctntr1 1cATE No. 37540 L03S00I6 .dt:..ASCADE LAND SURVEYING Comp/eh, Land Surveying Services --- (360) Buckley, WA., 98321 897-1017 (local) or 1-(800) 728-4993 (360) 897-1227 (fax) DRAWN BY:JAO (toll free) FOUND CONCRETE MONUMENT N 167989.612 (FT) E 1305752.756 (FT) IN CASE W/ J" BRASS DISK & "X''\ NOTES: 1. MONUMENTS LAST VISITED 12/ 12/02. 2. THE FIRST EXCEPTION -WITHIN Tl-IE DEED DESCRIPTION CALLS OUT "THE WEST 170 FffT". OCCUPATIONAL LINES, ASSESSOR MAPS AND ADJOINING DEEDS ALL INDICATE THAT THIS CALL IS IN ERROR AND SHOULD READ "THE EAST 170 FEff'. 3. REFERENCE SURVEYS: A. PLAT OF AKER'S FARMS NO. 5, VOLUME 40, PAGE 27, RECORDS OF KING COUNTY, WASHINGTON. B. RECORD OF SURVEY UNDER KING COUNTY RECORDING NO. 9105249007. w C) <( 0.... "" _J 0 > INDEXING DATA: NE 1/4, s.w 1/4, S[C. 29, T.23 NORTH, R.5 EAST, W.M. INSTRUMENT USED: TRIMBLE 5600-SERIES ROBOTIC METHOD: TRAVERSE EXCEEDING REQUIREMENTS OF W.A.C. JJ2-1J0-090. SURVEYED FOR: HA MINH CHAU SITE ADDRESS: 17034 106TH AVE. S.E. RENTON, WA 98055 JOB N0.:2002--024 SCALE: 1''=JO' SHT.:2 OF 2 DATE: 01/06/04 L--------------------------------------------~P~R~OJ~[~CT~N~A~M~[:~K~/~~,G~C~O~U~NT~Y SHORT PLAT FOR ~IA MINH CHAU/ !CREATED: Mon Dec JO 07: 1 a]°'""'7 -2-00"'"2-/""'/PJ.R-[V-. _P_LO_T_: -Tu_e_J-an-06-09-:4_5 ... :J_0_2'""00"·1-7-;""'pL-O""'rr"""Er.-): ... l-ue-.,-J-ar-1. -6-, -20-0-.,-, -9:0.-'j,-/;1_1_0M!"' ____ ""'"1"' ......... CONDITIONS OF APPROVAL King County Department or Oevelopmenl and Erwlronmental Si.,rvices 900 Oc1kesdale Avonufa SW Renton. WA 93055·1219 FikNo. File Name: COND(TlO~S OF APPROVAL LOJSOOIG Chau Short Plat Application Date: May 2, 2003 Revision Dale: January 30, 200-1- This ~hurt subdi\·ision is granted preliminary appro\'al ~ubject to the following Conditium of Apprornl. These conditions are based on a field visit and current. infor_m<ll_ion !he appli~~nt has provlded about tile short subdivision propeny. Oc:cusiomdly, in sat1sfymg the Cond1t1ons of ApproYal, a more definitive land use llmitation of the property may be rn-i:akd. New infomrntion (such as fimll Helllth appro1·al or senoitive areas revkw) nwy rq11ire additional conditions and may reduc<..: 1he number of lots. Final appru\'al will [>e gra111cd c1fla compliance \\"ith the Conditions of Appro,·al. Key codes and guideliiics han: bc.:cn noted lo pro\'ide guidance in prepari11g the rcquin:d plans and other documents. Comp] iance \\'ith some of the following conditions wi !I require that engii1ccring plans be prep:1n:d by a profcssion:il ci1·il engineer licensed in the State of W,1shingwn. I. 2, 3. Title 19A A. The short subdi1·i5ion sliaJI comply with all provi,;iuns ofTi,.le 19A. H. Tlie final rffiew process must be completed prior to reeordi11g of the sho11 subdivision. The Depar1ment of Oe\'clopme1!l and Environmental Scn·ices (UU!.:S) strongly recommends the Final S.hort Plat be submitted at ka~Q.l!!e. )~~nuirior to the expirntil)n date of the mo1ect. The final Sl1ort Plat >ubm1ttal package includes: 1. A surYcyc<l map p:1ge (four sets) induding lot area closure calculations; 2. Final health approval from die King County 1-kaltb 0(;p:1rtment (different from prelirninal)' health appronil); 3. A current shor1 plat c1.:r1lficate and supponlng documents (easi:ments, etc.); 4. Pciyment ofihe Final Short Plat ,;ubmittal fee; 5. A copy of this lettcr (preliminary approval letter). A licensed land su1Ycyor shall be hired to prepare the final short subdivision documents. These documents shall comply with all oftlie l(1llowi11g conditions for final appro\'al; C. All pcr~ons having an ownership interest in the subject prope11y arc required to sig11 the linal short subdiYision. D. Jf mvdlfications to the approved preliminary site plan (Attachment t) are ,we,kd to accomplish engineering design or final short plat, then a revised prdirninary site plan shall be submitted to DDES for review and approYal. The ievised site plans shall be submitted with the engineLrinl! plans or tl1e final slrnr! plat submittal. - Surface Wl.lter .'\Ianagemeni (KCC 9) 1998 King (ounty Surface Wakr Dcsign .\fauual (SWD!\1) A This c;hort subdi\'ision proposal is subject to Full Drain:ige Rel'iew per section I .1.2.3. Fin:il short subdi \·ision appro\·al slrnll require fol I cumpfrince with drainage provisions and storm drainage requirements of this section. Compliance may result in reducing the number and/or location of lots shown on th•: llpproved preliminary short subdi1·ision. Tl1e conditions outlined below are site-specific drainage conditions: {!) Core Requirement #1 -DischJrgc ut the Natural Lorntio11 (1) Core Requirement #2 -Off-Site Analysis (3) (•) (5) (GJ (7) (3) (S IJ Core Requirc,nent #3 -Flow Contrcil Core H.equiri:mrnt #4 -Com·cyaiH:e System Core Requirement !/6 -~foi111c1@JC<..: a:id Operclliur1 Core Hequiremeur #7 -Fin:rnci,d Gu.irautees & Lidiility Core Requirement #8 -\V:1!cr Quality Special Requirement #I -Other ,\dopted Rcquirc111crlls B. A profrssional ci\·il engineer Jieellsed in the State of Wasbi:1gton shall prepare a Tcc!J11ical Information Report all(ilor engineering phms per Chapier 2, of the 1998 1Zing County Surface Water Design Manual. Health (KCC 13) This project is exempt from fm1her King County Heath Depanment review. Howe1·cr, ifimprowments an: rc,111in:d from tile Sewer :md.1or the Water District, then \·eriticatio11 shall be rcqufre<l from said District(s) tlm the improvements have been bonded andlor inst;illed, prior lo final recordine of tl1c shofl pht. ~ 4. Road Stmidards (KCC 14) 1993 King County Road Standards, Ordinance 11187 Final short Subdivislon approval shall require full compliance with the pro\'isions set fonh in the King County Road Standards including engineering plans for all road improvemcnts. The cngin...:ering phrns shall be prepared by a professional civil engineer licensed in the State of\\'ashington. DDES strongly n:eornmends 1hc Enf!inei:rlng Plans be submitted ut least two_yeurs prior to tlt_e e:<..pirnlion date of the r12.i.££!. A. That ponion of the "\1onh half of SE t72"J Street adj vining the subject prope11Y slml! be improved to an urban Sub-access standard per KCRS Scction 1.03. B. Tlic1t portion ofll1e Ecistlrnlfof 10(/1 A\·cnuc SE adjoinillg the subject property shall be improved 10 an urban Sub-access standard per KCRS Section 1.03. 5. 6. 7. C I) F. G. The following not...:s shall be show11 on t/1c fiirnt recorded shoi1 subd[\'ision: I) 2) \\'urning· Kinn C t ] . · · . , · "' ou11 y ias c1u respons1U1!Jty to build, impro\'e, marn.tam Or otherl',-ISC St:f\'!C\: tile private roads contained wilhiri or P101 iding sen-ice lo the prop.:ny described in t!Jis shon subdl\·ision. All 11rirnte ,,."lSL·rne,,, .. ·, d 1 ·, · · 1 l · · · . '· J, n ·01 .r.ius o 1c malfltamed, rep:med nndlor rebuilt b)' !ht' o·\·1,.. . f ti . I I -· . . . _' ~rs o 1c p~rce s 1a1·mg legal access then~from arid :11c1r he1rs, assrgns ur succe;;sors, unless and umil such roads are m_ipro~cd to K.ir1g County st,md:irds and are dtdicated and accepted b Kmg County for malnknancc>. y ~\JJ :11i.litie~ \\'!Iii t1; prnp_usr:U righ1s-of-1\ ll y sh:11 l be inclutkd within a franchise dppl O\.ed by lr1e Krng C ou:11y Council prior lo final sho11 subdiYision rccordmg. H. All restrictions, e::iscments, tracts, and tl1eir purpose shall be sho'kn on the final rncorded sbort subdirisio11. Building anti Construction Standards (Title 16) Grading. The applicant shall comply \\'itil a!l :ipplicalJle provisions ofKCC 16.82. Fire Code (KCC t 7) Section 902 or the 1997 Edition of Uniform Fire Code The applicrrnt shall obtain tin: :1pprorn] uf the: King County Fire Pro1ectio11 Engineer for the adequacy of the fire hydrant, ,1·ater main, and fire flow standards of KCC J 7.08 prior to r<:coding of the lots. Zoning Code (KCC 21.\) A. Density and Dimensions (KCC 21 A. l 2) All lots shall med the de11Sity and dimensions requiren1ents of the R-8-SO zoue classificlltion or sl1all be .is shown on the face of the approved prclimi- na1-y short suiJlii1·ision, \\'liicl1e\'er is larger. f\linor revisions to the sbor1 subdil'ision, ,\·hich do not result in aubstantlal cha1wcs andlor do not create additional lots rmy be appr<J1-cd :.it tlic discretion oiiuso. D. Street Trees (KCC 21 A.16} Strc~t trees sh:dl be fJro1·idt>d along that portion of the right-of-way for I OG'" /\ 1 enue Southe:1st ::ml S011the<!'it 172"" Street c1bullillg the subject property, pursu:rnt to tl1e pru\'is1011s of KCC 21 ,\. I 6.050(E) and KCC 21,\.16.190, unless C.'i.isting tre1.·s c!l"C sbom1 lo be equivalent lo the requirement of Code. Sec> note below. The required street trees slrnll be designed as to location and spacing ori tlie final plan submittal. Jlie street trees must be in~!alled and inspC'ctcd, or ;1 perforrna11ce bond posted, prior to rccording of:!Jc plat. If a pcrformai1c<..: bond is posted, !lie street trees must be imtalled and inspected with111 one year uf recording of1he plat. At the time of inspection, if the tree~ are fou11d to be installed per 1he appro,,.ed plan, a ma!11tenancc bond must be ~ubmitled, or the performance bond replaced with a manl!enancc bond, and held for one y<:ar. After one year, the maintenance bond may be released after l}l)[S has completed a second inspection and Ucterniined tlial the trecs liave bee11 kept !1ealthy and thriving. NOTE: 1. KCC 2 IA.16.0:"~ Landscaping -~treet froutages. The avernge :\·idth ofperirn..:ter lant.h:::1ping along stn~et frontages shall be p1ovided as follo·,ys: For single-family sub<li\'isions: a. 1:'rees shall be plant~d at the n!te ofune trt>e for evciy 40 feet of frontage along a ne1ghborboc:d collector s1re<:t o!' arterial street. b The !recs shall be: L Locute.d within the street :iglit-of-way ifpermit1ed by the custodrnl state or local agency; 2. Nu more than 20 foet from the street right-of-way line ll'hen located wuhin a Jot; 3. !Vfa_intained by the adjacent landowner tmlcss pan of a County rnamtenance program; and 4. A species appron:d by tile Countv if located within the street right-of-way and compatible witl; overl1cltJ utility Jines. c. The trees may be spread at irregular inter\'als in order to :iccomm?date sight distance requiremems for Um·eways and 1nterseet1ons. 2. .KCC 21.:\.16.19? Fina11ci:J_1 guarante_rs. Financial guarnntees sliall be rcqu1rcd consistent \\'1lh the pro1·1sions of Title 27A. Signilie:mt Tree Reteution-KCC 21 A.33.230 wliicil :1pplics 10 the site, a U::tatb! tree retcr.111011 plan sh:ill be submi[[ed with the <.:nginecr!ng plans for the s~bJect r.!at. fhc lre_e n:tcntion plan (and engineering plans) shall be cous1s(ent.11ith the rec!u1r~·ments of KCC J IA.38.230, as well a~ the conceptual tree 1:etentwn plar.1 _wl11ch is pa11 _of the hearing record for 1his project. No elearrng of the s.uo1,·ct prop_cny 1s permitted Lmtil the final tree retemion plan is :ippro\·ed by LUSD. f!,1gg111g and telllporary fencing of trees to be retained :hall b~ prondcd, consistent witl1 KCC 2 !A.38.23004. The pl;icement of tmpcr\'JU~S surface_~. fill materild, excavation work, or the stoiage of co11strnet1011 matcna!s 1s prohibitcd \•:ithin the fenced areas nround preserved t1ec~, excepl for grnumg \1ork penni!ted pursuant to KCC 2 IA.38.230!34d(2). A ll?le shall be µlaced on the filial plat indicning that the trees shown to be rctmned on the tree rell·ntiou plan sl1all be mai11tained by the futurc owners of the proposed lots. L'011\istc11t 1\·ith KCC 2 IA.38.23086. (Note that tlie tree rete.ntion pl.in shall be indud<:d as part of the fina! engineering phms for the su_bJe.ct plat.) l[the~110 sig11ificm1t trees as ddined bv tl1e Suecia! Overlay D1stnct on the s11e th.en. this req~:in:me11.l4.~nnly_, The cxisti1!g liouse shall_ ~e 1·enw1'Cd or dcrnotisheU prior to the final approq[ nnd rccorJmg. A de111olH1on penrnl shall be obtained prior to d.-:111 olition. C. Pro\'ide 35' pa\'ed radii at the intersection of 1061" Avenue SE and SE !72 Street p<:r KCRS S...:ction 2.10. Dedicate a 25-foot property Jim; radius at the illterscction of! 06 1h Avenue SE and SE 172nJ Stre1;1 p<.:r KCRS Scctivn 2. l 0. Rod ;\ Ii I igatiou I' .iyment S:, , fl' m D. Existing roadside obstaclc(s) sh:111 be relocated to pro\·ide a minimum clearance of 10 feet from the edge of!hc tra\'cl lane to the obstacle(s) per KCRS Section 5.11. .E. f'ri,·:1tc c1ccess lo Lots 2 and 3 shall be shown as lljoirit-u,e dri1T\1·ay tract per KCRS Section 3.01. The tract sh,dl be an undi\·ided mn1ership to the lots it strvcs, and tl1e lot owners shall be responsible for its rrnintcnance. Tile tract sl1all be 10-fod 1\·idc \\'itl1 a 18-foot-1\·ide pawd surface. The tr:ict shall be: a minimum of 20 re~·t in lrngti1. UTILITY CONFLICT NOTE: CAUTION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE @ 1-800-424-5555 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSING TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE NOT GUARANTEED AND ARE SUBJECT TO VARIATION. LEGAL DESCRIPTION LOT 13, BLOCK 4, AKER'S FARMS NO. 5, ACCORDING TO THE PLAT THEREOF, RECORDED IN VOLUME 40 OF PLATS, PAGE 27, IN KING COUNTY, \..'ASHINGTON1 EXCEPT TIJE \..'EST 170 FT. AS MEASURED ALONG THE NORTH LINE THEREOF J AND EXCEPT THE NORTH 60 FT. OF THE REMAINDER, 9. I U. I The llpplicant shall comply with Road Mitigution Payment System (MPS), by paying the required l'vll'S fee as determined by King County Department of Trnnsport;ition, plus an t1dminis1rntive fee. Thl' applicant h.is an option to either: A. B. Pay the MPS fee at fin:.il short subdivisiou recording and the /\:IPS udministratiYe fee :.it final short subdivision application, or Pay the MPS foe .it building permit issuance aud the MPS administrati\'e fee at the llme of building permit applie<1tion. If option A is chosen, then tl1e following note shall be shown on the iin:il sbort plat: ,'\IPS FEE i\'OTICE: All fees required by King County code 14.75, Mitigation Payment Systc>m (MPS) hnvc been paid. 1f option B is chosen, then the following note shall be shown on the final sho11 plat: ,\JPS FEE i\'OT1CE: This short plat is subject to King County Code No. 14. 75, King County Ro.id i\1itigation l'ayment SysltrH (L\IPS). The lvlJlS f'ees plus the ;,_1ps administra(i\'e fc...: shall be paid at the time o/"building permit applici\lion at the rmc in cffrct ai that time. State E11Yironrm'nlal l'olit·y ,\cl (SEP:\) This short subdil'ision was exempt from the provision of the State Environmental Policy Act (SEPA). Other CoJ1sider:1tions Prelimina1y approYnl of this application does not lilllil Lile applicant's responsibility to obtain any required permit or license from the State or other regulatory body .. This may include obtaining a forest practice permit from t!J<: Wasbi11gton State Department of Natural Resoum::s for tree retllO\'al. VERTICAL DA TUM, NAD 83, PER \..'SDOT GE[JGRAPHICAL INFORMATION REPORT BENCHMARK, CONCRETE MONUMENT IN CASE\,'/ A BRASS PLUG~ THE INTERSECTION OF SR 515 & SE 180th ST. ELEVATION = 402.09' P[R \..'SOOT GEOGRAPHICAL SERVICES SURVEY MARK REPORT, MONUMENT LD, #2606 AND DESIGNATION #IS 1765. Vicinity Mop SW 23RD ST 1 • ! >-- 1 ':'j --.------·~ >: ...;{ <I > j ST ~ ---------- 5 ~ I .S~?2J_H __ .ST ' I I ST r-------· ,--- \__ Soils Map t N g''sE16S SE .'";·'TiOTri s Notice Required Contractors st,all notify operators who maintain underground utility lines in the area of proposed excavation or blasting at least two business days, but not more than ten working days prior to comtnencement of excavation or demolition in accordance with RCW Title 19. Names and telephone numbers of the operators of underground utility lines in this project appear below. These numbers shall also be used to serve in an emergency conditions as required. Phone SOOS CREEK WATER & SEWER DIST. (253) 630-9900 Sanitary Sewer SOOS CREEK WATER & SEWER DIST. (253) 630-9900 Water District PUGET SOUND ENERGY ( 425) 454-6363 Gas Company PUGET SOUND ENERGY (253) 395-6915 Power Company Call Before You Dig DIAL-A-DIG 1-800-424-5555 Notes 1. The Developer is required to notify the Land Use Services Division, Land Use Inspection Section (206) 296-6642, three days prior to the beginning of construction for a preconstruction conference and specifically request inspection before beginning: A. Installing siltation and erosion control measures B. Clearing and grubbing C. Earthwork D. Installation of any underground utility E. Before placing subbase, base or paving surfoces F. Installation of any forms or placlng any concrete 2. A permit must be obtained from the office of the Resident Engineer, Washington State Deportment of Transportation, before any construction is started on any existing stole route. 3. A Hydraulic Project Approval (HPA) Permit must be obtained from the Washington State Department of Fisheries pr:x to any work when required. Bonding Information Restoration Bond Amount $ ________ _ Performance Bond Amount $ -------- ~~-------- Site Plan Approval Approval of these plans is for construction of road and drainage improvements, site drainage & grading and temporary erosion control in unincorporated King County only. These plans do not authorize any other utility approval or improvements proposed in any State right of way. Site plan approval is void if the commercial building permit hos no\ been obtained or renewed within two years of approval. Subdivision plan approval is void if the final plat is no\ recorded prior to the preliminary plat approval expiration. ASSESSOR S NO.: 008700-0280 PRO RATA SHARE ASSESSMENT ANALYSIS (County Use Only) Section Township Range Tax Parcel Number 291 12131 10141 I o 10 I s 17 I o 10 I I o 12 I Bl o I Site Locotlon Is within the _ GR_EEti_BIVER drainage shed(s) Pro Rota Share Assessment(s) are: D Required D Not Required from the site due to development for increased storm water runoff. Peak Runoff Assessment Rate($ ) per c.f.s. lncreases.(10 year, 2 hour storm) Peok Volume Assessment Rate($ ) per Ac. Ft. increases.(2 year, 2 hour storm) AGREEMENTS, PLAN REFERENCES, PERMITS ETC. (To be completed by Consultant) Preliminary Pia\ Approval/Permit Issued Date: MARCH 12, 2004 Exp ira\ion Date: MARCH 12, 2009 Other Related Permit Numbers Received: Right-of-Way Use Permit Grading Building/Structural Other ______________ _ Board feet of tree removal on site: NONE Cubic yards of material hauled on/off the site: Is this a erosion sensitive area site? (Yes/No): ND Note: If "yes", a Highly Sensitive Site Erasion Control Supervisor is required. See ESC plan and TIR for details. ) Date Emergency 911 Police-Fire-Rescue RECOMMENDED FOR APPROVAL (To be completed by King County) Engineer Plan Reviewer Engineer Supervisor Traffic & Planning Engineer Sensitive Areas Structural Review Engineer Other APPROVED FOR CONSTRUCTION DEPARTMENT OF DEVELOPMENT & ENVIRONMENTAL SERVICES -a V ,= ~ '-V Date ® King County, Washington James H. Sanders, P.E. Development Engineer PROJECT CONTACT INFORl~ATION ___ H_A_M_I_N_H_C_H_A_U __ ---"( 425) 643-3993 Name 4101 150th AVE. SE Phone BELLEVUE WA. 98006 Address and Zip Code D A Partnership :81 An Individual ___ H_A_M_IN_H __ C_H_A_U __ __,_( 425) 643-3993 Name 4101 150th AVE. SE Phone BELLEVUE, WA. 98006 0 D Address and Zip Code '-'-~ Q) Q) Q) C > 0, '-:, C D A Corporation D A Partnership 13 An Individual --=-J=A=E--=-G--=-E=R'-----E_1V_G=I:c..N'-E_;;E=R-'-I_N_G _ __,_(-253) s5o-og 34 Name Phone '-OUJ ow 9419 S. 204 PL. KENT 98031 D 12 Address and Zip Code l-01 SRoZ. Z. f-Pl I (11-1,-P? ;vtHIII \ I L 0 (f) > L (]) Q ::J (/) "-L (]) (]) C CJ) C w "-+-' u (]) +-' _c u L <( C CJ) ff) Q) 0 (/) 0:: w m 2 :::::J z w __J LL (/) w 0 0 0 z -0: w w z -0 z w tt w 0 w <( J !L __ _ Q.) C,J ~ s:: -; I:':) ..q c:i ...., co 'i< o:i 0 (;\) • ..q ~ ...., :::s -0...., Ct) i:::: 0) ~ ~ 'i< 0) sj- 1') (]> 0 I 0 l{) CX) w a__ 0:: w (:) w <( ---, ---:, U) w :::!' <( ---:, K.C. D.D.E.S. ~ ~ 0 c:::, Ct) C'<) c:::, a ~ L '. L Q) Q) _Q _Q E E ::J ::i z z >, +-' +-' u > G) •--, +-' 0 u L <( [L (]) C 0 _c Q._ L 0 +-' 0 C --0 L 0 0 u +-' u (]) ·--, 0 L Q._ 0 z +-' C Q) E Q 0 (1) > (1) 0 License/Seal Sheet 1 of 3 __ __j_ ~ en [iuiJ /'T1 © -a 0 [iuiJ OJ "' = = c:s = = [iuiJ C=J I I ~ 3_90_~£----------a---- "' 0 ROFILE @ EXIST NORTH Pvl'.1T. EDG - -' u 0 385 '.i: 375 370 1+00 390 ,:, C r----' u 0 0 385 + 0 380 375 370 10+00 "' U1 3= x'-w a:: SCALE: 1" 1 " - - . - --.. - PROFILE @ PROPO ED CURB FLOW LINE ------------ 1 +52.39, 21.2' LT CB #2 (TYPE 1) RIM: 3B0.91 IE: 377.9 ' m •f co n 2+00 20' HORZ. 5' VERT. SE 1 7~ind ST. (URBAN SUB ACCESS) m· a:: 0 rJ u ROFILE @ EXIST (L EAST PVMT. EDGE .;-. N 0 ~·~:'-PROFILE_@ PROPOSED . I + J: CURB FLOW LINE 0 --- ""'j I A.6~ ------, ---, ~ ---' --. ' ,_ -.1, • ·--1\1 LO~ , PT OF CURB CB #3 (TYPE 1) RIM 377.1 IE: 375.5 (EX. 12") IE: 375.4 (NEW 12") SEl OVER EXIST. 12" "' .;- N 0) r--: 0) r--r-- I") I") SCALE: 1" 20' HORZ. 11+00 106th AVE. SE 1" -5' VERT. (URBAN SUB ACCESS) r z w :::;: 3= ~ --<( a:: (L (3-l (3-l 30' VARIES 5' 12' VARIES ---~.-;-1~--,--i f-o~------------~----- 2% SIDEWALK (L 0 w SAW CUT _o_.5-'"" 1--V_A_Rl~ES~±_7_.5_'-c-'(~10_6_t___,h)+--r-<---cl' INSIDE EX PVMT. (106th) 4' (172nd) 4' INSIDE E . PVMT. (17 nd) vi ---;:;i-- ~ 0 0 0 z w (() iJi .;- ' -- - I") .;--OJ n ' ~ET IE. 2+66.91, 26.2' LT CB 1 TYPE 1 RIM: 388.0 JE: 385.0 390 385 380 375 370 ----t-----------······----------+------, 390 385 380 375 370 3+00 STREET TREE -WESTERN LARCH (LARIX OCCIDENTALIS) PLANTE[;' 5' FROM R.O. W. LINE ( 4 TREES) 'REMOVE EX 10" CONC. RET. WALL 12' RCP # INV=36 -.7 1/4" EDGED SSMH ------------- A PORTION OF THE SW 1/ 4 OF SECTION 29, TWP. 23 N., AGE. 4 E., W.M. EX. 12' CCP 1INV=381.5 BLOCK 4 AKER'S FARMS ND. 5 VOL 40, PAGE 27 LOT 12 r t FLOW LINE TO BE ~ DIRECTED TO CATCH BASIN AS SHOWN ON PLAN ~ w 20' w z ~------+-------------z ::J TRACT ::J ~ ~ 0 0 SPHALT ~ -' 1 1· 3 , -18: 1· ~ A.C. PAVEMENT , IVF'f.!t:E CURB ------r~ I~ ~'t~=1:~i?~~Z~%~~f.-~~~r~~w-r.:-.:: :,~//~V// ///~///(:-Ilk:'/// --, '\., ' S ) --J ~~o o 0 0 °0 °0°0 00:ao"\00 0°/::, 0 -;-o o 00 00 ° 0 0 \ o O o O 00 0 0,~~ /&Ilk/I& 0 0 o O a O o O ~ ~;,,"v»~J/.§?ll~-vt~-,,,~ 's "-"' I ~7~/7Z?h, 0.5 @ BACK OF -2" COMPACTED DEPTH WEDGE \ CLASS "B" ASPHALT \_ 1 1/2" MIN. COMPACTED DEPTH CRUSHED SURFACING TOP COURSE 2 1/2" MIN. COMPACTED DEPTH CRUSHED SURFACING BASE COURSE 300.01' (CALC) 300' CPU'lT) ADDITIONAL TREATMENT MAY BE REQUIRED DEPENDING ON SOIL CONDITIONS. SEE SEC. 4.02 130.01' 1 +52.39, 21.2' LT CB #2 (TYPE 1) RIM: 380.91 IE: 377.9 12' CDNC. RET. \/ALL \/ITH WOOD FENCE (WALL ON PROP. LN,) !--- --I I I EX HOUSE I I L __ - TRACT ,, A" JOINT USE DRIVEWAY TRACT N.T.S. 13 EX, 12' RCP • ~ i:.:i ;:l Ct.; -/"--1115" / "R ~ I 1,,, I . . _-- . ,,._-+-· '-_,-Ci ' C' _-,i,b_,~---_"_1-----~---~2~.0~%~E==~~ffim~--~;~~E~XilS~T~/ ~G~PA~V~E~M:i;EN~Tcl1~7~2nd) "·' T/B= Ex,if,Ki'd, r%-;fr;Eiff-2tf86th) ci;'.' 4" THI CK _/ -_. --.. - , RIM=376,5 q~ t ~£ 2.0% ·-·-- tri t:a.i . i::::i . King County i::::i SE CONC. WALK VERTICAL CONC. 2" CLASS "B" ASPHALT CONCRETE CURB & GUTIER CROSS SECTION 172nd ST. & 106th AVE S (URBAN SUB ACCESS) N.T.S. 1.5" COMPACTED DEPTH CRUSHED SURFACING TOP COURSE 5" COMPACTED DEPTH CRUSHED SURFACING BASE COUSE ADDITIONAL GRAVEL MAY BE REQUIRED DEPENDING ON SOIL CONDITIONS \f:' \\: NOTE: 6" --1--'-'-'-~__,__-----1 5.0% --'.i-~. .. "' ·;. : 16" . - 78" OR 24" __j *NOT£: TOP OF CURB @ DRIVEWAYS CEMENT CONCRETE VERTICAL CURB AND GUTTER NOT TO SCALE 1. TRACT "A' IS A JOINT USE DRIVEWAY TRACT TO BE JOINTLY OWNED AND MAINTAINED BY LOTS #2 AND #3. 2. EXISTING WATER MAIN SHALL BE LOCATED BY POTHOLING l'RIOR TO INSTALLATION OF DRAINAGE SYSTEM. 20 0 ~ Department of Development and Environmental Services APPROVAL FOR SITE CONSTRUCTION Review Engineer ENGRCOMP Date GRAPHIC SCALE Senior Engineer ENGRCOMP Date 10 20 40 80 DEVELOPMENT ENGINEER APPROVAL Date I I t ti'.7 ~ ( IN FEET ) Comments: 1 inch = 20 ft. REVISIONS; h ~ h ~ ~ ~ a ~ ~ ~ ::.. "ill :S ll:; h 'O ~ C a .... ~ 'I< ~ ~ Clj i2 ~ -, ~ ::::i ~ f-' Cj u uJ ~ 0 "' a. ~ ::::i IC o:, ~-:,0:. ~ C t':l ~~~ c.:i ~ .... -..: :"i 'O ~ :S It::~ C ~Cl! ~ ~t;2~ ~.~ 0 2t1 0 '"'l 2:; ~ ~ t:tj R.; f-' z < u ::; a. a. < DATE: 3/16/07 SCALE: 1" = 30' DESIGN BY: JJJ DRWN. BY: JJJ APP. BY: FILE No. SHEET 2 OF 3 . ' GENERAL NOTES 1. All construction shall be in accordance with the King County Code (KCC), Road Standards (KCRS), and the King County Council's conditions of preliminary subdivision approval. It shall be the sole responsibility of the applicant and the professional civil engineer to correct any error, omission, or variation from the above requirements found in these plans. All corrections shall be at no additional cost or liability to King County. 2. The design elements within these plans have been reviewed according to the King County Department of Development and Environmental Services (ODES) Engineering Review checklist. Some elements may have been overlooked or missed by the DOES plan reviewer. Any variance from adopted standards is not allowed unless specifically approved by King County prior to construction. 3. Approval of this road, grading, and drainage plan does not constitute an approval of any other construction (e.g. domestic water conveyance, sewer conveyance, gas, electrical, etc.) 4. Before any construction or development activity, a pre-construction meeting must be held between the DDES's Development Inspection Unit, the Applicant, and ttie Applicant's Construction Representative. 5. A copy of these approved plans must be on the job site whenever construction is in progress. 6, Construction noise shall be limited as per King County Code (Section 12.88); normally, this is 7 a.m. to 10 p.m. weekdays and 9 a.m, to 1 O p.m, on weekends, 7. It shall be the applicant's/contractor's responsibility to obtain all construction easements necessary before initiating off-site work witiiin the road rights-of-way. 8. Franchised utilities or other installations that are not shown on these approved plans shall not be constructed unless an approved set of plans that meet all requirements of KCRS Chapter 8 are submitted to the DDES's Development Inspection Unit three days prior to construction. 9. Datum shall be KCAS unless otherwise approved by DOES. 10. Groundwater system construction shall be within a right-of-way or appropriate drainage easement, but not underneath the roadway section. All groundwater systems must be constructed in accordance with Section B1 3.02 of the APWA Standard Specifications. 11. All ulility trenches shall be back filled and compacted to 95 percent density. 12. All roadway subgrade shall be back filled and compacted to 95 percent density (WSDOT 2-06.3). 13. Open cutting of existing roadways is not allowed unless specifically approved by DOES and noted on these approved plans. Any open cut shall be restored in accordance wtth KCRS 8.03(6)3. 14. The Contraclor shall be responsible for providing adequate safeguards, safety devices, protE:ctive equipment, flaggers, and any other needed actions to protect the life, health, and safety of the public, and to protect property in conneclion with the performance of work covered by the contractor. Any work within the traveled right-of-way that may interrupt normal traffic flow shall require at least one !Jagger for each Jane of traffic affected. All sections of the WSDOT Standard Specifications 1-07.23 -Traffic Control, shall apply. DRAINAGE NOTES 1. Proof of liability inf;urance shall be submitted to DOES prior to the pre-construction meeting (KCC 9.04.100.D) 2. All pipe and appurtenances shall be laid on a properly prepared foundation in accordance with WSDOT 7-02.3(1). This 3ha11 include leveling and colllpact1ng the trench bottom, the lop of the foundation material, snd any required pipe bedding, to a uniform grade so that the entire pipe is supported by a unifom1ly dense unyielding base. 3. Steel pipe shall be galvanized and have asphalt treatment #1 or better inside and outside (KCRS 7.03). 4_ All draimige structures, such as catch basins and manholes, not located within a traveled roadway or sidewalk, shall ha~e solid locking lids. All drainage structures associated with a permanent retention/detent1on facility shall have solid locking lids (KCRS 7.05). 5. All catch basin grates shall conform to KCRS drawing numbers 2-013, 2-018, 2-019, or 2-020, which includes the stampi11g "OUTFALL TO STREAM, oUMP NO POLLUTANTS" and "Properly of King County" (KCRS 7.05). 6. All driveway culverts located within King County right-of-way shall be of sufficient length to provide a minimum 3:1 slope from the edge of the driveway to the bottom of the ditch. Culverts shall have beveled end sections to match the side slope (KCRS 7.03(L), Drawing No.2-001). 7. Rock for erosion protection of roadway ditches, where required, must be of sound quarry rock, placed to a depth of 1 foot, and must meet the following specifications: 4"-8" rock/40%-70% passing, 2"-4" rock/30%-40% passing; and -2' rock/10%-20% passing. lnsl<1llat1on shall be in accordance with KCRS 7.02(B) drawing number 2-024. 8. Drainage outlets (stub-outs) shall be provided for each individual lot, except for those lots approved for infiltration by Kin~ County. Stub-outs shall confornl to the following: a) Each outlet shall be suitably located at the lowest elevation on the lot, so as to service all future roof downspouts and footing drains, driveways, yard drains, and any other surface or subsurface drains necessary to render the lots suitable for their intended use. Each outlet shall have free-flowing, positive drainage to an approved storm water conveyance system or to an approved outfall location. b) Outlets on each lot shall be located with a five-foot-high, 2'' x 4" stake marked "storm" or "drain" The stLib-out shall extend above surface level, be visible, and be secured to the stake. c) Pipe material shall conform to under drain specifications described in KCRS 7.04 and, if non-metallic, the pipe shall contain wire or other acceptable detection. d) Drainage easements are required for drainage systems designed to convey flows through individual lots. e) The applicant/contractor is responsible for coordinating the locations of all stub-out conveyance lines with respect lo the utilities (e.g. power, gas, telephone, television). f) All individual stub-outs shall be privately owned and maintained by the lot homeowner. DETECTABLE VARNING (i;i_ / / 4' -O' MIN, 6' -O' MIN, PATTERN <SEE DETAIL) \-, · // .,;,,.¥~-i, , /8' EXPANSION JOINT (TYP,) TD, PLAN F-3) A / v~ / 7/ ~v0<:', CEMENT LANDING RAMP , -9 • "' , , ffiP~ 'ai~. }'~ l, ~. c°'.Lt .~~ eew,-, CONCRETE _/ f 7 ~\_. / ~ • t , -O, '\~' , / ~o ,"' MIN, ."\, : S!DEVALK DETECTABLE VARNING DEPRESSED PATTERN <SEE DETAIL) CURB & GUTTER (SEE NOTE 3) ?_,/ I~'.; SECTION (~) 1, ~;;>/ (;;>~ ,_; / \_.....,. I CROSS'JALK (TYP,) / <SEE STD, PLAN H-5c) 6' -0' MIN, I . I ::OJ_. TOP OF --~ ~.~l---,M ;ROADVAY I SIDE'w'ALK RAMP TYPE lA PLAN ~"~7------r-0 ·~ CEMENT CONCRETE L, \_. S!DE\.IALK CEMENT CONCRETE (.~B·\ CURB & GUTTER SECTION ) <SEE NOTE 3) NOTES L Avoid plo.cing dro.lno.ge structures, Junction looxes or other olostructlons in front of ro.Mp o.ccess o.reo.s, 2, Detecto.lole wo.rnlng po. tterns sho.ll Joe textured using trunco. ted do Me po. tter·n <see deto.Jl), 3, Curb o.nd gutter shown, see the Contra.ct Plo.ns for the curio design specified, See Std, Plo.n F-1 for curio deto.lls, 4, The plo.n views for SIDE'wALK RAMP TYPES lB, IC & 1D a.re provided to define ea.ch ro.Mp type, See the RAMP DETAIL on this sheet, See Std, Plo.n F-3 for sldewo.lk joint plo.ceMent and deto.lls, 5, Ro.Mp slopes sho.tl not be steeper tho.n 12H1! V, DRIVEWAY CURB CUT I~ ~/' " '- ~ I:,, ~ I M ', ~ ),_( I I'\ J NOTES: RICHT-OF-WAY LINE 1. SEE SEC. 3.04 K.C.R.S. FOR JOINT REQUIREMENTS. 2. ROLL CUITER TO MATCH POSITI\I[ SUPERELEVATION. 3. SEE DRAWING NO. 1-006 FOR CONFIGURATION OF FILL & WN....WAY BEHIND CURB IF REQUIRED. 4. FOR INTEGRAL POUR CONSTRUCT/ON, 1/4" EDGED GROOVE MAY REPLACE EXPANSION JOINT AT INTERFACE BETWEEN THE CURB AND ADJACENT SIDEWALK. 5. SEE SEC. 3.03 FOR EXTRUDED CURB ANCHORAGE. VARIES RIGHT-OF-WAY LINE MATCH EXISTING DR1YEW1W GRADE DRIVEWAY CURB CUT SEC rlON A-A CE~ENT CONCRETE DR1VE'WAY 5" ll-llCK NOTES: 1, FOR WIDTHS OF SIDEWALK SEE SEC. 3 02. 2. FOR WIDTHS OF PAVEMENT AND SHOUI_DER SEE SECS. 2.02, 2.03, AND 2.04. 3. SHOULDER SHALL BE SURFACED AS REQUIRED BY SECTIONS 3.07 AND 4.D1, IF PAVED, SHOULDER SLOPE SHALL MATCH CROWN SLOPE OR .02 FT./FT. 4, 5. FOR CURB AND SIDEWALK JOINTS SEE DWG, NO. 3-001. TRANSITION RAMP SHALL BE TEXTURED BY IMPRINT OF METAL GRID WITH 1/2" SPACING. 4" CEMENT CONCRETE SIDEWALK AND RAMP ... .<I • • ·,.d 6'-0" MIN, 12 SECTION A--A CEMENT TRANSITION CONCRETE SIDEWALK TO ASPHALT SHOULDER EROSION AND SEDIMENTATION CONTROL NOTES 1, Approval of this erosion and sedimentation control (ESC) plan does not constitute an approval of permanent road or drainage design (e.g. size and location of roads, pipes, restrictors, channels, retention facilities, utilities, etc.). 2. The implementation of these ESC plans ancl the construction, maintenance, replacement, and upgrading of these ESC facilities is the responsibility of the opplicont/ESC supervisor until all construction is approved, 3. The boundaries of the clearing limits shown on this plan shall be clearly flagged by a continuous length of survey tape (or fencing, if required) prior to construction, During the construction period, no disturbance beyond the clearing limits shall be permitted, The clearing limits shall be maintained by the applicont/ESC supervisor for the duration of construction, 4, The ESC facilities shown on this plan must be constructed prior to or in conjunction with oil clearing and grading so as to ensure that the transport of sediment to surface waters, drainage systems, and adjacent properties is minimized. 5, The ESC facilities shown on this pion are the m1n1mum construction period, these ESC facilities shall be upgraded account for changing site conditions (e.g. additional sump requirements for anticipated site conditions. as needed for unexpected storm events and pumps, relocation of ditches and silt fences, During the modified to etc.). 6, The ESC facilities shall be inspected daily by the applicant/ESC supervisor and maintained to ensure continued proper functioning. Written records shall be kept of weekly reviews of the ESC facilities during the wet season (Oct. 1 to April 30) and of monthly reviews during the .dry season (Moy 1 to Sept. 30). 7, Any areas of exposed soils, including roadway embankments, that will not be disturbed for two days durin9 the season or seven days during the dry season shall be immediately stabilized with the approved ESC methods (e.g., .. seeding, mulching, plastic covering, etc.). wet 8, Any area needing ESC measures, not requiring immediate attention, shall be addressed within fifteen (15) days. 9. The ESC facilities on inactive sites shall be inspected and maintained a minimum of once a month or within 48 hours following o storm event. 10. At no time shall more than one (1) foot of sediment be allowed to accumulate within o catch basin, All catch basins and conveyance lines shall be cleaned prior to paving. The cleaning operation shall not flush sediment-laden water into the downstream system. 11. Stabilized construction entrances and roads shall be installed at the beginning of construction and maintained for the duration of the project. Additional measures, such as wash pads, may be required to ensure that all paved areas are kept clean for the duration of the project. 12. Any permanent flow control facility used as a temporary settling basin shall be modified with the necessary erosion control measures and shall provide adequate storage capacity. If the facility is to function ultimately as an infiltration system, the temporary facility must be graded so that the bottom and sides are at least three feet above the final grade uf the permanent facility, 13, Where straw mulch for temporary erosion control is required, it shall be applied at a minimum thickness of 2 to 3 inches. 14, Prior to the beginning of the wet season (Oct 1), all disturbed areas shall be reviewed to identify which ones con be seeded in preparation for the winter rains. Disturbed areas shall be seeded within one week of the beginning of the wet season, A sketch map of those areas to be seeded and those areas to remain uncovered shall be submitted to the DOES inspector. The DOES inspector can require seeding of additional areas in order to protect surface waters, adjacent properties, or drainage facilities. MATCH EXISTING OR PROPOSED SURFACE ASPHALT CONCRETE CONSTRUCTION SEQUENCE 1. Arrange and attend a preconstruction meeting with King County DOES Inspections Unit. Call (206) 296-6642. 2. Flag clearing limits and easements. Flag property lines. 3, Post sign with name and phone number of ESC supervisor. 4. Flag all trees that to be saved. 5. Grade and install quarry spall construction entrance. 6. Install silt fencing as shown on the plans. 7. Maintain erosion control measures in accordance with King County standards and manufacturer's recommendations. 8. Relocate surface water controls or erosion control measures, or install new measures so that as site conditions change the erosion and sediment control is always in accordance with the King County Erosion and Sediment Control Standards. 9. Cover all areas that will be unworked for more than seven days during the dry season or two days during the wet season with straw, wood fiber mulch, compost, plastic sheeting or equivalent. 10. Stabilize all areas within seven days of reaching final grade. 11. Seed or _sod any areas to remain unworked for more than 30 days 12. Upon completion of the project, stabilize all disturbed areas and remove BMPs upon approval of the Inspector. King County Department of Development ond Environmental Servlces APPROVAL FOR SITE CONSTRUCTION Review Engineer ENGRCOMP Date Senior Engineer ENGRCOMP Date DEVELOPMENT ENGINEER APPROVAL Dote Comments: 0 z -a: w w z -C, z w a: w C, w RE\1SIONS: ffi <( ~-., h ~ ~ 0~ ~ "11 1/) ;'3 h~ 0 .... ... ~ ~ <::, Cl':, !'.. .... ~ ~ "' Cj u w -, 0 °' 0.. l"l ::::i IC o:, ~ <::, 0:, ""!~ <::, l"l t:tj CO I u ~o:,~ "11 ~ IC ~ .r:: ~---,.., IQ <::, r:.:i <:\! ~ ~S;~ c~~ ~ ~~ ' ~ "' z < u :J 0.. 0.. < ti) ~ ~ q ~ ~ ~ ~ DATE: 3/..16/..07 SCALE: 1 " = 30' DESIGN BY: JJJ DR\\N. BY: JJJ APP. BY: FILE No, SHEET 3 OF 3 ~- I SHORT PLAT NO.~~~- KING COUNTY, WASHINGTON N BASIS OF BEARINGS: THE CENTERLINE OF 106TH AVE. S.E., BEING N01'43'14"[ PER THE PLAT OF AKER'S FARMS NO. 5, ACCORDING TO THE PLAT RECORDED IN VOLUME 40 OF PLATS, PAGE 27, RECORDS OF KING COUNTY, WASHINGTON. LEGAL DESCRIPTION: (PER STATUTORY WARRANTY DEED UNDER REC. NO. 9711120779) LOT 13, BLOCK 4, AKER'S FARMS NO. 5, ACCORDING TO THE PLAT THER[OF RECORDED IN VOLUME 40 OF PLATS, PAGE 27, IN KING COUNTY, WASHINGTON; EXCEPT THE WEST (EAST, SEE NOTE 2 BELOW) 1 70 FEET AS MEASURED ALONG THE NORTH LINE THEREOF; AND EXCEPT THE NORTH 60 FEET OF THE REMAINDER. VERTICAL DATUM: NAO 83, PER W.S.0.0.T. GEOGRAPHIC INFORMATION REPORT. BENCHMARK: CONCRETE MONUMENT IN CASE W/ A BRASS PLUG @ Tl-IE INTERSECTION OF SR 515 & S.E. 180TH ST., ELEVATION = 402.09' PER W.S.D.O. T. GEOGRAPHIC SERVICES SURVEY MARK REPORT, MONUMENT 1.0. #2606 AND DESIGNATION #IS 1765. CB RIM=377.3 KING COUNTY SHORT PLAT FOR HA MINH CHAU LOCATED IN THE N.E. 1 /4, OF THE S. W. 1 /4, OF SECTION 29, TOWNSHIP 23 NORTH, RANGE 5 EAST, KING COUNTY, WASHINGTON W.M., RECORDING NO. SCALE: 1 inch = 30 FT. 30 PORTION OF: VOL./PAGE GRAPHIC SCALE • • §I 0 111 =30' ""-----' 30 N.E. 1 / 4, S.W. 1 / 4, SEC. 29, T. 23 NORTH, R. 5 EAST, W.M. SSMH RIM=J8J.O 10" CONG. RET. WALL 12" RCP INV=379.1 JO' II II ASPHALT D/W APRON II I BLOCK 4 AKER'S FARMS NO. 5 VOL 40, PACE 27 LOT 12 ~ ---------_______________ 3~0.01' (CALC) JOO' (PLAT) I 130.01' ---------------------_____ _ \ CONG. '\; HOUSE f:l 130.02' 'Ji. ( '<l-SBB' 16'46" E ~ 79.83' \ I 110.00·--------------------- 12" CONG. RET. WALL WITH WOOD FENCE (WALL ON PROP. LN.) I 1...-----W. LN. OF E. 170' AS MEASURED I ALONG N. LINE OF LOT 13 I (W. 170' DEED) J; "l 1,9A S. LN. OF N. fi 60' LOT 13 Jk WOOD FENCE INTERSECT/ON O.J'± S. & O.J'± E. OF PROP. COR. HOUSE LOT 13 LOT 14 FOUND LARGE PK NAIL & WASHER WITH LS STAMP (UNREADABLE #) @ S.E. 1 70TH ST. t ' INV=375.2 N. 18" RCP INV=J75.2 E. 12" RCP INV=J75.1 S.W. 12" RCP SITE BENCHMARK: TOP CENTER BOLT OF FIRE HYDRANT LOCATED @ THE N.E. QUADRANT OF INTERSECT/ON OF S.E. 172ND ST. & 106TH AVE. S.E., ELEVATION = 378.40'. CONTOUR INTERVAL: 2 U.S. FEET LEGEND: CONCRETE MONUMENT IN CASE AS DESCRIBED SET 1/2" REBAR & CAP "LS 37540" FOUND PK NAIL AS DESCRIBED FIRE HYDRANT BOLLARD ~ WATER METER 61 WATER VALVE ~ CATCH BASIN @ SANITARY SEWER MANHOLE :g:: UTILITY POLE -:l GUY ANCHOR § MAIL BOX INV=369.7 SURVEYOR'S CERTIFICATE THIS MAP CORRECTLY REPRESENTS A SURVEY MADE BY ME OR UNDER MY DIRECTION IN CONFORMANCE WITH THE REQUIREMENTS OF THE SURVEY RECORDING ACT AT THE REQUEST OF HA MINH CHAU IN Jan. 2003 S.E. 172ND ST. 661.43' (CALC) 661.35' (PLAT) FOUND CONCRETE MONUMENT IN CASE W/ J" BRASS DISK & "X''\ @ P.C. OF 108TH \ :.::..:====-=8r-..,,_,__ S88'0J'25" W 719.93' (MEAS) L03S00l6 NOTES: 1. MONUMENTS LAST VISITED 12/12/02. 2. THE FIRST EXCEPTION WITHIN THE DEED DESCRIPTION CALLS OUT "THE WEST 1 70 FEIT'. OCCUPATIONAL LINES, ASSESSOR MAPS AND ADJOINING DEEDS ALL INDICATE THAT THIS CALL IS IN ERROR AND SHOULD READ "THE EAST 170 FEIT'. 3. REFERENCE SURVEYS: A. PLAT OF AKER'$ FARMS NO. 5, VOLUME 40, PAGE 27, RECORDS OF KING COUNTY, WASHINGTON. B. RECORD OF SURVEY UNDER KING COUNTY RECORDING NO. 9105249007. ITS)~~~~~~~\ lJu MAY O 2 2003 UJ) K.C, D.D.E.S. w 0 <( [L "' _j 0 > ~CASCADE LAND SURVEYING INDEXING DATA: NE 1/4, s.w. 1/4, SEC. 29, T.23 NORTH, R.5 EAST, W.M. INSTRUMENT USED: TRIMBLE 5600-SERIES ROBOTIC METHOD: TRAVERSE EXCEEDING REQUIREMENTS OF W.A.C. 332-130-090. Complete Land Surveying Services SURVEYED FOR: 11722 261st Ave. E., Buckley, WA., 98321 HA .MINH CHAU F rr, 8 ~u * CONIFEROUS TREE (360) 897-1017 (local) or 1-(800) 728-4993 (toll free) (360) 897-1227 (fax) DRAWN BY:JAO JOB M0.:2002-024 SCALE: 1"=30' SHT.:2 OF 2 DATE:01/13/03 EXPIRES SITE ADDRESS: 17034 106TH AVE. S.£. '"'< r:- RENTON, WA 98055 ,e ., PROJECT NAME: KING COUNTY SHORT PLAT FOR HA MINI-I C/-IAU. '/CREATED: Mon Dec JO 07:18:07 2002//PR[I/. PLOT: Mon Jon 06 08:41:29 200 '/PLOTTED: Mon., Jan. 13, 2003, 9:13:08 C: Cascade Prajects\2002 2002-0v -· . - • -. n. -- ·t>~-~ • TRENCH CROSS-SECTION --- FILTER FABRIC -4" PERF. PIPE 1-1/2"-J/4" WASH[O ROCK -, SLOPE __ ,._ PLAN 14[W OF ROOF TO ROAO ORA/NACE SYSTEM 2' X 10' LEI/EL TRENCH WITH P[RFORATEO PIP[ TYP. LOT PERFORATED STUB-OUT CONNECTION NO SCALE NOTE• EACH LOT SHALL INCLUDE A PERFORATED STUB OUT DRAINAGE CONNECTION TD THE STREET DRA!MAGE SYSTEM. VARIES 5' 12· f- ~ (l_ X w G' ~---------. 8.5' ~---------,------------ SIDEWALK 8'-9.5' 0 c' • CJ 2.5'-4' i----------r--SAW CUT MIN. 12" 2% '---------~=~ .. J .~ , .. :·~ _ ... 4" THICK CONG. WALK VERTICAL CONG. CURB & GUTTER ' 2.0% INTO EXIST. PVMT. '-EXISTING PAVEMENT 2" CLASS "8'' ASPHALT CONCRETE -1.5" COMPACTED DEPTH CRUSHED SURF ACING TOP COURSE 5" COMPACTED DEPTH CRUSHED SURFACING BASE COUSE ADDITIONAL GRAVEL MAY BE REQUIRED DEPENDING ON SOIL CONDITIONS TYP CROSS SECTION 106 AVE SE. & SE. 172 ST (URBAN SUB ACCESS) N_T,S. TRACT 'A'• JOINT USE DRIVE\./AY TRACT FOR LOTS 2 AND 3 @----- • A PORTION OF THE SW 1/4 OF SECTION 29, 1WP. 23 N., AGE. 4 E., W.M. SSMH RIM=376.5 TEMP. SITE. BEN_CHMARK: RIM OF SAN SE\./ER MAN HOLE: ELEV, 383.0 TEMP. SITE BENCHMARK: RIM OF SAN SE\./ER MAN H[ILE: ELEV, 375.8 130.01' NOTES: ! 1. PUBLIC STREET FD~T AGE IMPROVEMENTS: 12' TD FACE OF CURB SHALL BE M~ASURED FROM THE CENTERLINE OF THE EXISTING PAVMEri-JT . 2. END NEv/ CURB,_ GYTTER 2x SIDEv/ALK AT THE v/EST EXTENSION OF LDT tt_\ ALONG SE 172 ST. 3. TRACT "A" SHALL J1 E A JOINT USE DRIVEv!AY TRACT FOR THE BENEFIT OF LOTS #2 AND #3, - 4. ALL LOTS SHALL TILIZE A PERFORATED STUB-OUT DOv/NSPDUT DRAINAGE/-CONNECTION TO THE -STREET DRAINAGE SYSTEM. BLOCk 4 AKER'S FARMS 1\10. 5 VOL 40, PAGE 27 LOT 12 300.01' CCALC) 300' (PLAT) ' co (\J (J) ' -- ... ·. co (\j (J) 0 -- -~"------~- • '_e,;,;'.",' • •· ·-,•. 'O';"'" ~ • LOT 13 I -r---- --_J l I I EX HOUSE I I g )= L--- • 18 (/) 12' RCP 12' RCP r!NV=390.3 I 20 0 GRAPI-Illf SCALE 10 20 40 ---I J .J , ( IN l'EET ) 1 inch 'f 20 ft. 80 RECEIVED JAN E O 2004 KING COUNTY LAND USE SERVICES L03S00I6 RE'lfSIONSo 1--------·· ,: C . '/ SCALE: 1" = 20' , _ , - DESIGN BY: . JJJ ORIIN. ElY: J;/J j_:A.::.__PP:...:_·._:B:;__Y:-=::::::=:;:_j • . FILE No. SHE:ET OF 1 -1 . ·, ' ... ,.: , _A·- ' '1 / / / / ------------- /---------------------------------i-----------;-·--------.-~----, Pion Approval CONDITIONS OF APPROVAL ® King County Department of Oevoloprnon\ and Erwirommmtal Survi~o~ 900 0,:1~esc:ole Avenue SW Ronton, WA 93055-1219 Fik No. File N:mic: Application Date: Revision Date: CONDIT!O:','S OF APPROVAL LOJSOOl6 Clii1U Short Plat J\faY 2, 2003 JaJJUUry 30, 2004 This short subdi;·ision is granted preliminary approval subject to the following Conditions of Approral. These conditions arc based on a field Yisit and current information the applicant has provided <1bout the c.bOJi subdlvision property. Occasionally, in satisfying th~ Conditions of Approval, a more dcfi!lilin: laud use limitation oftbe propeny may be rcn:alcd. New infornmtion (such as fimil Health ,1ppro\'al or srnsitive rm .. ,1s r,:riew) rn.iy require additional conditions and may reduce the rwmber of lots. F. G. H. The fuilt1\1i11g notes sh;dl t,e slio11·n o11 ih-.: final recorded slwrt ~Libdi\'ision; I) ."::.irni.llg: King county !rn ilU r-:sponsibility lo build. i1nproYe, . ll,iln.ta.111 Or Otl.1r1 I\ 1S<: St'J"\"JCe th,: ;in qlte roads ern;(;:in,·d within Or )'IU\1dmgsc·n11.··w·l1c I ·b · 1. ' propi.:ny, ,:,·<n i.:d 111 this ~i1()rt :,ubdivlsio11. \JI 1~1·ivme eas~·111l·nts a11LUor tr:11.·ts tu be maintain..:d. i't:p:1ircd m1d'or n:bui!t by tJ·c ,y,1·ners f I · ' . . , _ · o t 1e JX!I'L'Cls h:n mg kgal access 1h-:1drom and 1lie1r he1rs, ass1gm .or sur:eessurs. u:11,...ss a11d until suc::1 ro:lds an: l!nproved to King Count, T , I <l . _ ) s ,.iw:ll\ s an are d\:!dica1d :~!1d .eci.:epted b)' King County Jcir nrn.rnteiiar:ce 2) ,\JJ t1!ilitie~ wit.hi111•1oposed rigJ 11 ,-.0 ,:11 ,.,, sh·il! b<: ,1,,.,.1,., ,,.,·.1 1 ,· , 'I)·, lb ! K' , · ") '· '.i.u,.u .. ma ranc111se '! ()Hn_e, Y tie mg County Council prior to final sl10rt subdi1·isio,1 rcco1d1ng. · A!I n:strictiuns, easements, trac1~, nn<l their purpose shall be sho1\ n on the final recorded short subdi1·ision. Final appro\'a[ will be grnnted after cornplbnce wilh the Conditions uf Approved. Key codes and guidelines lrnve bee11 not<.'d 10 prodde guidan_ce in preparing the required plans and Olher documents. Cornplir1nce 1vi1h s0111e oftl1e following i.:onditions will reqmre that engineenng plans be prep.ired by a prufessio1nl civil engi1wl.!r !icl.!nscd in th~ State of\\'ashi11gwn. 5. Building a111l Constrn<:tion StaJJll:mls (Tille JG) I. Title 19A 2, J, A. B. The! short subdi1·ision shall comply with nil provisions ofTi!le 19.--\. Tlic Jina! rc\'ie\1' process must be completed prior to recording of1.hi:: s!Jort subdi\'isiotl. The Department ofDewlopmc11t and Environment:il Ser\'ices (DOES) :,ltongly rci.:ornmends the Final.Short !'lat b~ submitu:d <!t lc:ast one war prior 10 the expiration date of the J!l:9.iIT!· Tbe Final Short Pl.!t submitrnl packuge i11clude~: l. A sun eyed map page (four set,) including Jot area do·sure calculations; 2. Final Jicalth approval from th:: King County Health Department (dif!i;rcnt ftom pn:llrnlnary health .ipprn1·al); 3. A cutTeilt sbo11 plat ce11ificate and suppo11ing documents (easements, etc.); 4. Payment of th<.: Fi11al Short Pl.it submittal Jee; 5. A cupy oftl1is lcner (preliminary approvnl ktter). A licensed land sur1·eyor sinll be llin;J lo prepare the final short s11bdivision docurnent:i, Tllese documents shall comply with all ofU1e following conditiom for fi11:il llppro\'a!: C. All pcr$u11s havlng an ownership intl..'rcst in the subject property ure required to sign the fornl short subdivision. D. Jf modifications to the approved preliminary site plan (Attacluncnt J) are needed I() Hccomplish engineering design or fin.ii shon plat, then a revJsed prelimina!'Y site plan shall be subrnined lo DOES for n:\·iew and appronil. The rev1Sl'd site. plans s!ia!l be subm111cd \\'ith the engineering plans or the final sho11 plllt ~ub1mttal. Surfnce \\'att'r :ilnn:igcmcnt (KCC 9) 1998 King Couul}' Surface Water Design .\lauuul (SWDi\I) A. This shon_subdivision proposal is subject to Full Drainc1gc Review per section l. l .2.3. Furnl ~hurt subdi,·ision appro\'c1l $hall require full compliance with drnlnage pr·ovisions and storm drninage requirements oftbis section. Complianr:e may result in reducing the 11umber anJ/or location of lots sho1-1'n on tl1e ;ipproved preliminary short subdi\'ision. The conditions outlined below c1re ~ite-spr:cifk drainage conditions: 8. (!) Cc1re Requirement ill -Discharge at the Natura! Loc::tion (2) Core Requirement #2 -Off-Site An,1!:,sis (3) Con; Ret1uin.-me11 t /13 -flow Control (4) Core Requirement #4 -ConYcym1r:e System (5) Cure lfrq";'"'""' #5 -Erosio, & S,d;m,u1,1t;ou Cm1trnl (6) Core Hequircuieat #6 -\laintemLnce and Op<."'mt:un (7) Core Requir·c111ent i/7 -fin:.mcial Glmrnn(ees & Liability (8) Con· fkquin·1J1L'Hl #8 -IV,ih:r Quality (Sl) Spedal Requin,ment #1-Other Adopted Requir<.'rne11ts A profe~siot1:i.l ci\·il e.ngineer licensed in tbe State of Washington sliall prepare a Technical lnfonrnt1on Report nnd/or cngin~ering plans per Chapter 2, oft11e 1998 King CoLrnly Sud':.ice Water Design J\fanu:il. Health (KCC 13) This projed is exempt from forther King County Heath Departmcnt review. However, if 1111p1·0•.·t'll'.tnts are required from tl1c S•~\\·cr :md/or ;he Wakr ~istrict, tl1e1l n:ritica1ion shall be rc4uired from s:iid Uistrict(s) ih:it the 1mprovcme11ls 11:1\'e becn bonded andlor installeJ. ptfor to final reconling of the short pl.it. 4. Road StamJnnls (KCC 14) 1993 King Couuly Road Standards, Ordiaanrc 11187 final sl1ort Subdivision apprlwal shull require full compliance with the prol'isions sct forth in the King County Road Standards incl11Ui11g engineering pluns for all road impro\·cmc11(S. The engineering plans shall be prepared by a prufrssional civil englncer lice11sed in the State ofWashingtor1. DOES strongly recomrnends the Engineering Jllrms be submitted al lertst t\\'O ~·ears.prior to t]1c expirution date of the proicct A. That por~ion of the North hc1lf of SE l 72"J Street c1djoini11g th<.: subject propaty shall be 1mpron·d to an urban Sub-;1cc·c~s ~t,mdard per KCRS Section 1.03. B Tl1at po~ion of the East halfof 106 1h ;\\-cm1 1~ SE adjoining the subject propcny · shall be improved to an urban Sub-aC'CL'SS standard pa KCRS Section 1.03. 6. 7. C. D. Grnding. Tl1e awlieant shall comply with all applicabk p10\·isions ofKCC 16.82. fire Cude (KCC 17) St·ctiun 902 oflhe 1997 £di1io11 uf l'11Iform Fire Code ·i he applica11! sh:ill obtain the app,o\·al ol'the Kli:g County fire Prokctioo Engiuccr for the <idequacy of the fire hydrant, wat,:r main, auJ lire tlow stanJ:1rJ~ of KCC 17.08 prior co recoding of the lots. J_oniug Code (KCC 21.-\) A. Density and Dimensions (KCC 2 !A. I 2) All lots slm!l meet the density .ind dimensions requirr:m...:nts of the R-S~SO zone cl:issificmion or shall be as 5hO\\'ll on the face uftliC! appro\'Cd prclimi- :1:iry shot1 subdi1·ision, wl1icht'\'Cr is lar~cr. l\linor ie\'isions to the short subdi,,ision, which do not result in subs'ianti,d cli:1m•es arKlitir do not create :1dditionc1l lots may be :lppr1.wed ,1t the discretion or'iuso. B. Stres:l Tre~s (KCC 2 l A.16) s;,n:,~t trees shall b,· prnridc,;J along that portio11 oftht ri),'.ht·of-way for I u6· · A ,·cm1e Somhc;1st and Soul)lt'.ast I 72"d Strci:t abuning tile subj<:ct property, pursuanc w the pr0\·is1011s ol'KCC 2J . .;,JG.050(E) :i11J KCC 21.-\.16.190, unless eAiscing trees arc shown to be equ1l'akr:t 10 lilC! requirement of Code. s~,c n,,te lidow. 'J'l1c required street trccs shall be Ue~igneci as to location :wd sp:1l·i11g on the Jina! plan submillal. Tlie street trees must be ins(a!led mid inspccied. vr ,, performance boud posted, prior to r,:cording oftbe plat. Jf :1 pafurn1;1r1ce bonJ is posted, die stP~d trees must be !nstallc? an? mspccted wi:!11n 011<: year ofrccot·ding of the JJbt. At the time of 111s~eet10n, 1flhe trees arc found tq be installed per the approveJ plan, a 111a~ntena.nce bond must be sub111i1ter.l, or tl1e perfor111:rncc lmll(I repbced \\'ith a n@ntcmmce bond, .ind !JL'ld for 011e year. Afler one yccir, thi: maintcur1nee bond may be released after DDES has completed a secoud inspection and detennmed tlrnt the trees lrn1·e be,:n kept healthy :ind thriYing. !\GTE, l. KCC 21,-\.16.050 Landsr:aping-street front:iges. The average \:'idtli ofperimder landoca::,jng doJ1g street frontagcs shall be pro\·!ded us follows: For si1igle-fam1 ly subdi1 isions: a. ·:.recs shall be pbnt~d at tile r:ite of one tree for every 40 feet of ~routugi,; along a neighborhood co!!ector strL'Ct or arterial street. b. fhe trees shall b,...: I. Locutc.d wltliin the street riglit-of~way ifpermiued by the custodial stdle or local m:cncv· 2. No more thar1 20 f'eer fro~n tl;c 1street right-of.way line \1 hen located wiihin a lot; 3. ~1aintaincd by tl1e adjacent landowner unless part of a County n1,rn1te1wnc..: program; and '+. :\ speci:5 appron·d by the County if located withi11 the S(I\'l·l ngbt-ol-11·ay :,nd compatible with 01wbcad utility lines. c. The trees may be sprend at irrr;g11lJr intervals in order to ~ccomm:1date sight distance requirernenb for dri1·eways and mterscet1ons. 2. !'-CC .ZJA.16.190 Fin:rn<:ial guarunll'es, Financial guarimlees shall be rcq111n:d consi;:;1<.:nc w11h the pro\·isions ofTitk 27.·\. Sign_ilir:111t Tree ~~·trntion· KCC 21A.3((130 1d1il·h applies to the silL', a ds:1;111l'J trL'e reter.\11011 pl:111 shall. be submitted with tile eugirm:ri 11 g plans for Lilc ~.uli1ect P.l:1t. fhc ll"C_l' ret~·11t10n plan (and engines:,ing plans) sllall be ct:i~si~te.''.'..1\Hh '.lie r.e~LJJrrn1cnts ofKCC 2!.A.JS.230, as wdl as 1!1c co11cep:u,il l~~c r.du,,1.on pLm .11 h1ch JS p::1 t of the heanng record for this projc,.:t. ;,.:0 ci<.::tnng of the subJect propnty is pel'mitted trntil the fiilid tree retention pl:ri is approi-cd by .LUSD. flagging and icmporary fl'ricing ofln'l'S to be reuincci ih:ill li~ prOl'Jde.d, con;i~lent 1\·.lth KCC ~IAJS.23013.4. The pl;iccmrnt of impcr\ 10'.1s surl:!ces, Jill mat,·rial, r:xca\·.1tio11 \\'OJ'k, or lhe stornl!c uf t01JS!iOet1011 J~\:Jterja]~ IS pro]11b1t;;:J l\'it!Ji11 the felli.:r:d ·,1rl''1S arot~ld presetTCd trees, exeepl r,ir gr.idrng 11 or].,; pen11ittcd pursuant to KCC 2 IA.3S.23/Jfl4J(2). A 11;i1c shall b,: placed on th,.: fin;1l pL11 indicating 11,at tilc trees shown to be rL"tarncd on t/1<; l!L'e retention 11k_i11 shall be maintained by the futme 01\·tKrs of the proposl.'d lots. L·Onsistcm 11·1:h KCC 21 AJS.23013(). (;',1 ote that ihr: tree r,''.c.11t1rn1 plan :ii.ill be incluJcJ :is pan oJ' 1he fowl l'llgincerin'-' pl:ms ri.ir the ~ll.DJ~',c.t plat.) 1L1~1~e-~u~ ~ig11i !kalll l[e~s as defoh·d bv tli_e~Special Q~_erlav l2..L'-1Ut9.t!...ill.£."!'..~_t!.1 __ \c'.!l._..lh1s re::1u1remo,:r,!_tloes not :,1,;,i,::, - Jl.e e.\isti1~g bousc ~lia/1. b-; n:11101 ed or denmlisbed µ1·ior to tile fiual appro\·al c1nJ iecordrng. A d<.'molitio11 pcnrnt slrnll be obtained prior to demolition. Pro\·ide 35' pa\·ecJ radii at the in1ers<.'r:tion of 106 1'' Avenue SE a:iJ SE )72 Stred pe.r KCRS Section 2.10. Dcdicc1tc a 25-fout property line r:1dius at the 111terscct1on of 106'1, /\YC1rne SE and SE l 12' .J S:reet per KCRS St:etion 2. ! O. 8. Ro:id .\litig:1tilJ11 l'aym~nt Sy,toc 111 C. D. E.,:;isting roadside obstacle(s) slrnll be rcloc,1IL'd !ll proYirJe a minimum eleanu1ce of 10 feel f1om the l'dgc ofihc trn1·cl lane rn the obsrncle(s) per KCRS Section 5.11. E. Privc1te access to Lots 2 nnd 3 shall be shown as ajoint-t1se dri\'Cway trnr:t per KCRS Section 3.01. The tract shall be au 11ndiviJed 011·rn::r$hip to the lots it se1Yes, and the lot owners shall be responsible for its maintenance. The tract shall be 20-fret \1·ide \\'ith:, 1S-foot-\\'idc p;m:d surf::cc. The tr:1ct ~11:dl be ,1 minimum of20 feet in length. UTILITY CONFLICT NOTE: CAUTION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE @ 1-800-424-5555 AND THEN POTHOLING ALL OF THE EXISTING UTILITIES AT LOGA TIONS OF NEW UTILITY CROSSING TO PHYS/CALLY VERIFY WHETHER OR NOT CONFLICTS ~XIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE NOT GUARANTEED AND ARE SUBJECT TO VARIATION. LEGAL DESCRIPTION LDT 13, BLOC!< 4, AKER'S FARMS NO. 5, ACCORDING TO THE PLAT THEREOF, RECORDED IN VOLUME 40 OF PLATS, PAGE 27, IN KING COUNTY, \/ASHINGTON1 EXCEPT THE \/EST 170 FT. AS MEASURED ALONG THE NORTH LINE rHEREOF 1 AND EXCEPT THE NORTH 60 FT, OF THE REMAINDER, <), JU. Thc applicant sh:ill comply with Ro:id Mitigation Payment System (/'vfPS), by paying the required MI'S foe as detrnni11l"d by King County Depal'tment or Transportation, plus clll adminis1r,11ivi; fee. The :1pplic:i.nt has an option to (;itl1cr: A. Pay the .\JPS fee at final short subdivision rccon.lin!;l aud tllr: J\1PS administrutive fee at Ji:rnl short subdivisiorJ applica1iun, or U. Pay tl1e ,\fPS fce at building permit issuance and 1l1c J\1PS 11dminimative fee at the time: of building pennit application. lfoptio11 A is s.:hose11, then the following note shall Lie shown on the final slrnrt plat: i\ll'S FEE ;',,'OTJCE: All fees required by King County code 14.75, Milig:ition Paynwnt System (:\!PS) have been paid. If option B is chosen, then the following notc shall [J~ sho\1 non tbe final shmi pl:it: i\Il'S FEE .\'UTICE: This short plat is subject 10 King County Code No. 14.75, Kirlg County Road .l'..-!itig,11ion PaynlL'nl Systcm (:\!PS). The i'dPS frcs plus the !',!PS :1drninistrali\·c fr~ sll:il! be paid m the time of building po.:1rnit application at the rate in efkn :n til,111im12. State Envirou111t:ntal J'ulir:y ..\r:t (SEl'A) This short subJi\'isiou 11 ,1s nempt from the pro1·ision of th<: Sl:nc: Em·ironmenrnl f'olicy Act (SEf'.-\). Oilier Considerations Preliminary appro1·c1l of this :ipplication docs not limit 1l1e appliearn's responsibility to obt:1i11 any required petmit or license from the State or othr:t· regubory body .. This m,l) i!1clude obwining a forest practice pcrJllit from the Washington Stille Dcpm'tment of ~,11ural Resources for tree removill. lt0DE>< CD\JER PRl\1 M ~ ~ Rof\b PLAN 1',.lDTES 'f DEr/1.1 L:°, j 2 3 L'}-T E.S.C.P. T!<.EE. PLA~ l/ t NOTE-: u .s. P.s. L.CcA:llDW Ot--'l PILL i',, /<ING, OJoNti PDEs. VERTICAL DATUM, NAD 83, PER \/SDDT GEOGRAPHICAL INFORMATION REPORT BENCHMARK< CONCRETE MONUMENT IN CASE\// A BRASS PLUG@ THE INTERSECTION OF SR 515 & SE lBOth ST, ELEVATION = 402.09' PER \/SOOT GEOGRAPHICAL SERVICES SURVEY MARK REPORT, MONUMENT I.D. 112606 AND DESIGNA TIDN #IS 1765, Vici n it y M a p :< . vr ' Sh' _23flD ST. ' >-~ _ii --------i > -.! ----·--~I_. ' SW 29TH ST ·1 ···-· ""--- 1l t N Soils Mop ' Notice Required Controctors sholl notify operotors who mointoin underground utility lines in the area of proposed excavation or blasting at least two business days, bul not more than ten working days prior to commencement of excavation or demolition in accordance with RCW Title 19. Names and telephone numbars of the operators of underground utility lines in this project appear below. These numbers shall also be used to serve in an emergency conditions os required. Phone SOOS CREEK WATER & SEWER DIST. (253) 630-9900 Sanitary Sewer SOOS CREEK WATER & SEWER DIST. (253) 630-9900 Waler District PUGET SOUND ENERGY ( 425) 454-6363 Gas Company PUGET SOUND ENERGY (253) 395--6915 Power Compon y Call Before You Dig DIAL-A-OIG 1-800-424-5555 Notes 1. The Developer is required to notify the Land Use Services Division, Land Use Inspection Section (206) 296-6642, three days prior to the beginning of construction for a preconstruction conference and specifically request inspection before beginning: A. Installing siltation and erosion control measures B. Clearing and grubbing C. Earthwork D. lnstcllotion of any underground utility E. Before placing subbase, base or paving surfaces F. Installation of any forms or placing any concrete 2. A permit must be obtained from the office of the Resident Engineer, Washington State Department of Transportation, before any construction is started on any existing state route. 3. A Hydroulic Project Approval (HPA) Permit must be obtained from the Washington State Department of Fisheries prior to any work when required. 1----------------------------------·------------- Bonding Information Restoration Bond Amount $ -------- Performance Bond Amount $ -------- Site Approval of these plans is for construction of road and drainage improvements, site drainage & grading and temporary erosion control in unincorporated King County only. These plans do not authorize any other utility approval or improvements proposed in any State right of way. Sice plan approval is void if the commercial building permit hos n<Jt been obtained or renewed within two years of approval. Subdivision plan approval is void if the final plot is not recorded prior to the preliminary plat approval expiration. L 0 U) ·;;: L (]) 0.. ::J (/) -....____ L Q) (]) C (J1 0 z ..... a: w w z - st "' O> 0 I 0 I{) ro Q) C 0 _r Q_ As=s=E=-s-s-c-o-:-:-R-.,.-s-N-. -o-. : __ o_o_8_7o_o_ --02_8_0----1 ~ 0 z w w CL L 0 +--' 0 C PRO RATA SHARE ASSESSMENT ANALYSIS (County Use Only) Section Township Range T ox Parcel Number I 213 I I Ol 4 I I o 10 I 8 17 I o IO I I o 12 I Bl o I Site LocaUon Is witrdn the _ GR_EEf'!_l3IVER dra;nage shed(s) Pro Rota Share Assessment(s) ore: D Required D Not Required frorn the site due to development for increased storm water runoff. Peok Runoff Assessment Rate($ ) per c.f.s. lncreases.(10 year, 2 hour storm) Peck Volume Assessment Rate(·J ) per Ac. Ft. increases.(2 year, 2 hour storm) +-' u Q) +-' _r u L <( C (J1 U) Q) 0 rr: w (j w 4'. 'j a:: w (.'.) w <( -, -; (/) w ::: <( -, "'CJ L 0 0 u +--' u (l) ·~ 0 L Q_ >------·---------------------------4----------1 AGREEMENTS, PLAN REFERENCES, PERMITS ETC. (To be completed by Consultant) Preliminary Plat Approval/Permit Issued Dote: MARCH 12, 2004 I Expiration Date: MARCH 12, 2009 Other Related Permit Numbers Received: ' Right-of-Way Use Perrnit Grading Buildin g/Structurol , Other _____________ _ ~oard feet of tree removal on site: NONE ' pubic yards of material hauled on/off the site: _____ _ I Is this a erosion sensitive area site? (Yes/No): ND ' Note: If "yes", a Highly Sensitive Site Erosion Control \ Supervisor is required. See ESC plan and TIR for details. Ernergency 911 Police-Fire-Rescue ~---------------------·------------------' Date RECOMMENDED FOR APPROVAL (To be completed by King County) Engineer Plan Reviewer Engineer Supervisor Traffic & Planning Engineer Sensitive Areas Structural Review Engineer Other ,___! ___________________________ J-_________ _j {PPROVED FOR CONS1'RUCrflON DEPARTMENT OF DEVELOPMENT & ENVIRONMENTAL SERVICES Date f \ ' '-~ ~ tj.: ID ~ > ,L '- .(!) :J 0//J D L <l) <l) C 0, L C ow 12 King County, Washington James H. Sanders, P.E. Development Engineer PROJECT CONTACT INFORMATION ___ H_A __ M_I_N_H_C_H_A_U __ __,.( 425) 643-3993 Nome Phone 4101 150th AVE. SE BELLEVUE, WA. 98006 -'~~~~~----------- Address and Zip Gode D A Partnership £1 An Individual ___ J._IA_M_IN_H __ C_H_A_U __ _____ICC 425) 643-3993 Name 4101 150th AVE. SE BELLEVUE WA. 98006 Address and Zip Code Phone (/) O:". w CD 2 :::) z w _J LL (/) w 0 0 - L (]) .0 E ::J z >, +--' ·;;: +-' u <( '' L Q) .0 E ::J z +-' u Q) ·~ 0 L [L . 0 z +-' C (]) E Cl. 0 (]) > (l) 0 Lie en se /Seal ~, .... ,., - sS J. J,i~ o~ ' • /;;' (\Y • ~ -. , ,'<'~,0, WA "~( D A Corporation \', .,, -: D A Partnership I ~ " ,!y;. 6', J.AEGE'D E'NGINE'ERING 13 An Individual' { . 'ss'''"'""'':;iG',:.'' ~· --==_;_.c..n_=-:cc.__::=.:.===c_c;:_ __ ..,:(253) 850-D934 10NAL s~~ ·1/\ -........ ,. ~\' Name Phone EXPIRES: 3/1/2010 9419 S. 204 PL .. KENT 98031 Address and Zip Code Sheet 1 of ~ ~j __ a: = = c--, U) ill ci ci 0 :,2 . ' ---__ , ---------------------------- --_ == -·--:-L---'oRoF1tI~fxisi:--___ T~-=-t=-=:-:-::=.:::·--:::-= _ __ r-----t---1--; t-fr r-~[ ---~ --:,::-· ,_ t l "°"'J PW. EPO o~ I ' -T ---: ._t--,-,-]--390 -3 g_o_ ~--e--------~-~--~--=:= -PROFllE-@b;-~P06QJ_ ie.:_}-==-: -=:~-=--r~=~---~ ~J::::==-H!L:J r--~f r--<L~7 - 31'-f= ------ G--------1·--f-----_, I CU"8f ,COW LJ,C [ l: I ' --· . I --·t-.-- g ___ f-_~---r--~---!--C-L r --f--------~'-9 _i ___ ,_t:--+-:::-t-~D~,l,_2··J~C(T_ ------=:=- _ 3!35_~ -=:-=L :=_:_-----1==-= 1----E--=!~~-~ ~~~~I~ ':_: ___ ~-~-=-==~=':~ 8?,2:::=:::::1:==1--- 385 __ ------! -----f-----~--~-~ ----=---~--t--q:::=-i---··c=---------r~--------+--~-------r----····----------r· ---_:::....""" -----L------;;-'6 ~ ----" · 1---,; rF"7e-;-s-:-5--t ---------1-----,--------------'------···----: ;; c-p ·· -,---,------··---T-------ql~#l(TYPE-1) ----1 --1 --380 ------·-____ ---:_ ________ T --------~--·-------~-------+------------------------crj----11e:.J.esJ5rL __________ ; __ =+ ------1 --_L-----L----~----t--! ··--r-t~ f ------· ---l·-=r-- ---' ---T--C--------------~ -r--..;. ' I C) I I --,----··i C---1--1----1----i-------I _;_;-'---~ I i ---=375 3 7 5 I ·-------·-rr--·-. -J -i--,-r·-----,--~L__ ____ ,,. . ---------·-··r·-~ ------..: o··--...... ! i -! ----1=-----------~ -----.--1±5 ~..3.9.,..+t.2'.. rL-----~----------_=r____ ' tl-----~----r-,---~ ---·----I T 1. cs_,,_(ri>Ll ---·-------·------------'-----w __ -_ ---1---~4----RIM:, 380. 1 , I ' «i : -----------·--------+-__ f--------------·-----------+,--,--------------------------·--------------------,--- IE, p77. 9 . r I • 1 _ . . I 3 7 Q ___ 1__·-_ --_:::::-_ ! --r:_ : =--= T --r -~::: -:::::L . i -----_:_ 3 ?_Q __ 1 +00 SCALE: 1" 1 " ~ d P1 , pi ~ 20' HORZ. 5' VERT. 2+00 SE 172nd ST. OJ n I OJ U) n 3+00 (URBAN SUB ACCESS) STREET TREE (TYP) -WESTERN LARCH (LARIX OCCIDENTALIS) PLANTED~ _390 10+00 SCALE: VARIES I 1 " 1 " 5' SIDEWALK 0.5' <D 04 cri I' n 20 1 HORZ. 5' VERT. 30' ..- (J) (J) I' 10 11 +00 106th AVE. SE (URBAN SUB ACCESS) [L 0 12' w SAW CUT r z w 2 w > <{ [L 0' I - "' '-.. Cl:'. 0-' - VARIES 5' FROM R.O. W. LINE ( 4 TREES) n ..--OJ 10 - VARIES ±7.5' (106\h)i--1 I' INSIDE EX PVMT. (10 th) 4' Tt72nd) --~ INSIDE El PVMT. (17fnd) u·•,·,,i. 2__=_ _,) _ _ Ex1sT1NcPAVEME%ffigct) '\ "'~· _/ ,!.-'-' _c"L--,-\ ·.·_· 1 EXISTING PAVEMENT 106th) 5" 1/4" 1:DGED I-2% ,, I 7"R 7 -----GROOVE ~ 2.0% ']:· 4" THICK CONC. WALK VERTICAL CONC. CURB & GUTTER CROSS SECTION SE 172nd ST. & 106th AVE S (URBAN SUB ACCESS) N.T.S. 2" CLASS "B" ASPHALT CONCRETE -1.5" COMPACTED DEPTH CRUSHED SURFACING TOP COURSE 5" COMPACTED DEPTH CRUSHED SURFACING BASE COUSE ADDITIONAL GRAVEL MAY BE REQUIRED DEPENDING ON SOIL CONDITIONS 7''* 11 ' ' , , ' 6" ' 5.0% I - ,. ..... !. :l. - ' " ', , I I '' ' '" ' " " ' , /8" *NO[£: TOP OF CURB @ ORIVEWA YS CEMENT CONCRETE VERTICAL CURB AND GUTTER NOT TO SCALE A PORTION OF THE SW 1 / 4 OF SECTION 29, TWP. 23 N., F~GE. 4 E., W.M. SSMH NOTE: PER KCRS SECTION 4.1 OF, A 1 INCH FULL WIDTH OVERLAY SHALL BE REQUIRED ALONG THE PROPERTY FRONTAGE OF 106th AVE. SE AND SE 172nd ST. APPROPRIATE REPAIRS TO THE EXISTING SUBGRADE, BASE MATERIAL, SURFACING AND PRE-LEVEL MAY BE REQUIRED PRIOR TO PLACING THE OVERLAY. THE OVERLAY MAY BE WAIVED ONLY UPON WRITTEN REQUEST AND AFTER AN EVALUATION OF PAVEMENT CONDITIONS AND /OR CHANNELIZATION REQUIREMENTS HAS BEEN COMPLETED BY THE COUNTY ROAD ENGINEER OR DEVELOPMENT ENGINEER. NOTE: BLOCK 4 AKER 1 S FARMS NO, 5 VOL 40) PAGE 27 L[JT 12 130.01' 1. TRACT "A' IS A JOINT USE DRIVEWAY TRACT TO BE JOINTLY OWNED AND MAINTAINED BY LOTS #2 AND #3. FLOW LINE TO BE DIRECTED TO CATCH BASIN AS SHOWN ON PLAN w 20' w z--~~-i----------~,z ~ TRACT ~ r r 0 0 ~ ~ 1'1 18' :' --1--i-A:-c·.--P-Av_E_M_E_N_T_ --·- THICKENED 1 3' / EDGE CURB ~ r------- 1 t ~·, 2% -~~ =~' ==-=..:S:::' -s..=:s=;///0'-//$','.'/~Vk ///~.,W°"'-hlc::,"'///~::s::,-~s:: \_\f ~~. ' ~ • 0 -J-:· '.-,;-;-;;-.------,-·----:-,-:--·,. o",'o\·: ,,'• ,,·:·;:s/~:/:,.<, , , ,', o, , ' , ~· o -· -7;7:'.~//l-..;;:'ii/-§/11,..:::. ll~/ll::,c /. f..... ' 'l/.-T1T/Q/io:(71T:;-" 0. 5 @ BACK OF --' ' \. ,, WEDGE \ --2 COMPACTED DEPTH CLASS "B" ASPHALT 1 1/2" MIN. COMPACTED DEPTH ' co (\J (J', \ CRUSHED SURFACING TOP COURSE 2" l T 2 1/2" MIN. COMPACTED DEPTH CRUSHED SURFACING BASE COURSE ADDITIONAL TREATMENT MAY BE REQUIRED DEPENDING ON SOIL CONDITIONS. SEE SEC. 4.02 'fRAC'f "A" JOINT USE DRIVEWAY TRACT---~ N.T.S. J' ~" \_ 2" ASPHALT CONG. PA Vf:MENT THICKENED EDGE ASPHALT DETAIL L.DT 13 i--- j I I EX HOUSE I I NOT TO SCALE L __ _ s: )! ~!([:~1~? OT~~~E~ T :~~;E~~A~~;gH I , 5' INSIDE OF R.O. w. LINE ( 4 TREES) ~ -1 o' UTILITY EASEMENT (TO PSE & OTHERS) I ii fl EX ELEC PO',/ER POLE TD BE RELOCATED / 1 -BEHIND SJDE',/ALK BY PSE (PER 1993 KCRS) King County Department of Developrnent and Environmental Services APPROVAL FOR SITE CONSTRUCTION Review Engineer ENGRCOMP Date 2. EXISTING WATER MAIN SHALL BE LOCATED BY POTHOLING PRIOR TO INSTALLATION OF DRAINAGE SYSTEM. GRAPHIC SCALE Senior Engineer ENGRCOMP Date DEVELOPMENT ENGINEER APPROVAL Date ( IN FEET ) Comments: 1 inch = 20 ft. REVISIONS: . f!EV. PER CTY. of-1MENTS 10-1-0 1. f!EV. PER CTY. COMMENTS 10-20-08 "' 0 Lu ~ 0 "' a. "' z <( u :::J a. a. <( &-4 f7l ~ 0~ ~~ CJ) :S &-4 ~ 0 .... ~ "'11 O') <::) t'j "" .... ~ ~ (;.j ' ~ ct, ~ 0 ~ ~ ts ~ ..... ~ i:::i DATE: 3/16/07 SCALE: 1 " = 30' DESIGN BY: JJJ DRWN. BY: JJJ APP. BY: FILE No. SHEET OF 2 4 GENEnAL NOTES 1. All 0onstruction shall be in accordance with the King County Code (KCC), Road Standards (KCRS), and the King count/ Council's conditions of preliminary subdivision approval. It shall be the sole responsibility of the applicant and the pnifessional civil engineer to correct any error, omission, or variation from the above requirements found in these plans. All corrections shall be at no additional cost or liability to King County. 2. Tho design elements within these plans have been reviewed according to the King County Department of Development and Environmental Services (DDES) Engineering Review checklist. Some elements may have been overlooked or missed by the DDES plan reviewer. Any variance from adopted standards is not allowed unless specifically approved by King County prior to construction. 3. Approval of this road, grading, and drainage plan does not constitute an approval of any other construction (e.g. domestic water conveyance, sewer conveyance, gas. electrical, etc.) 4. Before any construction or development activity, a pre-construction meeting must be held between the DDES's Development Inspection Unit. the Applicant, and the Applicant's Construction Representative. 5. A copy of these approved plans must be on the job site whenever construction is in progress. 6. Construction noise shall be limited as per King County Code (Section 12.88); normally, this is 7 a.m. to 10 p.m. weekdays and 9 a.m. to 10 p.m. on weekends. 7. It shall be the applicant's/contractor's responsibility to obtain all construction easements necessary before initiating off-site work within the road rights-of-way. 8. Franchised utilities or other installations that are not shown on these approved plans shall not be constructed unless an approved set of plans that meet all requirements of KCRS Chapter 8 are submitted to the DDES's Development Inspection Unit three days prior to construction. 9. Datum shall be KCAS unless otherwise approved by DDES. 1 o. Groundwater system construction shall be within a right-of-way or appropriate drainage easement, but not underneath the roadway section. All groundwater systems must be constructed in accordance with Section 81 3.02 of the APWA Standard Specifications. 11. All utility trenches shall be back filled and compacted to 95 percent density. 12. All roadway subgrade shall be back filled and compacted to 95 percent density (WSDOT 2-06.3). 13. Open cutting of existing roadways is not allowed unless specifically approved by DDES and noted on these approved plans. Any open cut shall be restored in accordance with KCRS 8.03(8)3. 14. The Contractor shall be responsible for providing adequate safeguards, safety devices, protective equipment, naggers, and any other needed actions to protect the life, health, and safety of the public, and to protect property in connection with the performance of work covered by the contractor. Any work within the traveled right-of-way that may interrupt normal traffic flow shall require at least one flagger for each lane of traffic affected. All sections of the WSDOT Standard Specifications 1-07.23 -Traffic Control, shall apply. DRAINAGE NOTES 1. Proof of liability insurance shall be submitted to DOES prior to the pre-construction meeting (KCC 9.04.100.D). RiG."H-Oi"-WAY LINE DRIVEWAY CURB (SEE SEC. FIG 3-0: 2) 3/8" EX:=,ANSION JOINT (TYP ) (]) Dll'ECT!18LE 1NAPr-JING Pf\TERN (SEE DETAIL) SIDEWA.LK 6' ___ , ~ fAIN. , '· CUT CURB, OR CURB Nm GUTTrn NOTES: 1. SEE SEC. 3.04 K.C.R.S. FOR JOINT REQUIREMENTS. 2. ROLL GUTIER TO MATCH POSITIVE SUPERELEVATION. 3. SEE DRAWING NO. 1-006 FOR CONFIGURATION OF FILL & WALKWAY BEHIND CURB IF REQUIRED. 4. FOR INTEGRAL POUR CONSTRUCTION, 1/4" EDGED GROOVE MAY REPLACE EXPANSION JOINT AT INTERFACE BETWEEN THE CUF,B ANO ADJACENT SIDEWALK. 5. SEE SEC. 3.03 FOR EXTRUDED CURB ANCHORAGE. PUV·mNG STRIP R:crrr-o;;--wAY Ll~iE SECTIOLL.fl-A crnrnT CONrnETE DRIVEWAY 5" THICI< 9'-0" 16" 2'-7" 5'-0" ( ANCHOR BOLT PATTERN PER NDCBU PEDESTAL TEMPLATE 1 -lT 3/8" x FULL DEPTH ~ 6"r I r~ I EXPANSION JOINT f:llc,___: J f::::J:==J ' ,, -. . ,, ' . ' <o I ? 10'-o" 10'-o" ------0-------\ ~ ~ j 2.0' MIN FOR mUNCATED DOfAE SECTION PVMT. TEXTURE-- CEMENT CONCRETE SIDEWALK AND RAMP u· MIN. olATCH EXISTING OR PROPOSED SURFACE ________ SFi:::TION __ A-A _______ _ NOTES 1. SEE SEC. 3.02 FOR SIDEWALK WIDTHS. 2. SEE SECS. 2.02 AND 2.03 FOR PAVEMENT AND SHOULDER WIDTHS. 3. SHOULDER SHALL BE SURFACED AS REQUIRED BY SECS. 3.07 AND 4.01. PAVED SHOULDER SLOPE SHAl.L MATCH CROWN SLOPE Of< 0.02 FT./FT. 4. SEE FIG. 3-·00 I FOR CURB AflD SIDEWALK JOINTS. ® RAMP SHALL BE TEXTURED USING TRUNCATED DOME PATTERN. (SEE FIG. DETECTABLE WEARING PATTERN SHALL BE YELLOW IN COMPLIANCE WITH WSDOT STANDARD SPECIFICATIONS 8-1 ',.3(3) 6. THIS DETAIL APPlicS TO ROLLED AND VERTICAL CURB ROADWAYS. SIDEWALK TRANSITION RAMP N.D.C.8.U. 3-01' 2. All pipu and appurtenances shall be lald on a properly prepared foundation in accordance with WSOOT 7-02.3(1). This shall include leveling and coinpactirlg the trench bottom, the top of the foundation material, and any required pipe bedding, to a uniform grade so that the entire pipe is support~d by a uniformly dense unyielding base. --· CROSS\/'IALK I . l'-5 ". I -·-----~ ? --j-----------=-----,--,---.--,-----"'-------------l-- 1 I CUTLER MODEL CB-6 OR EQUAL~ 3. Steel pipe shall be galvanized and have asphalt treatment #1 or better Inside and outside (KCRS 7.03). 4. All druinage structures, such as catch basins and manholes, not located within a traveled roadway or sidewalk, shall have solid locking lids. f\11 drainagi.l otructures associated with a permanent retention/detention facility shall have solid locking lids (KCRS 7.05). 5. All catch basin grates shall conform to KCRS drawing numbers 2-013, 2-018, 2-019, or 2-020, which includes the stamping "OUTFALL TO STREAM, DUMP NO POLLUTANTS" and "Property of King County" (KCRS 7.05). 6. All driveway culverts located within King County right-of-way shall be of sufficient length ta provide a minimum 3:1 slope from the edge of the driveway to the bottom of the dltch. Culverts shall have beveled end sections to match the side slope (KCRS 7.03(L), Drawing No.2-001). 7. Rock fur erosion protection of roadway ditches, where required, must be of sound quarry rock, placed to a depth of 1 foot, and must meet the followlnu specifications: 4"-8" rock/40%-70% passing; 2"-4" rock/30%-40% passing; and -2' rock110%-20% passing. lnc;!allation shall be in accord.ince with KCRS 7.02(B) drawing number 2-024. 8. Draim.1(Je outlets (stub-outs) shall be provided for each individual lot, except for those lots approved for infiltration by King County. Stub-outs shall conform to the following: a) Each r;Utlet shall be suitably located at the lowest elevation on the lot, so as to service all fUture roof downspouts and footing drains, driveways, yard drains, and any other surface or subsurface drains necessary to render the lots suitable for their intended use. Each outlet shall have free-flowing, positive drainage to an approved storm water conveyance system or lo an approved outfall location. b) Outlets on each lot shall be located with a five-foot-high, 2" x 4" stake marked "storm" or ''drain". The stub·oul shall extend above surface level, be visiblo, and be secured to the stake. c) Pipe material shall conform to under drain specifications described in KCRS 7.04 and, if non-metallic, the pipe shall contain wire or other acceptable detection. d) Drairiuge easements are required for drainage systems designed to convey flows through individual lots. e) The applicant/contractor is responsible for coordinating the locations of all stub·out conveyance lines with respect to the utilities (e.g. power, gas, telephone, television). f) All individual stub-outs shall be privately awned and maintained by the lot homeowner. FIRE HYDHANT OR UTILITY POLE LUfAINAIRE 15' MIN. I~,~ PLANTING STRIP ~~ , Mltl· SIDEWALK NEXT TO VERTICAL CURB SIDEWALK- CURB RAMP 1 A @ DETECTABLE WARNING PATIERN AREA SHALL BE ~ .A YELLOW, IN COMPLIANCE i ,_B WITH STD. SPEC. 8-14.3(3)---',-: -I @ -@ MIN. MAX. A 1 5/8" 2 3/8" B 5/8" l 1/2" C 7/15" 3/4" A . @ @ PLAN @. -, @ --CEMENT CONC. Si)EViALK RAMP TYPE '!A D 7 /8 ~1 f/16" :::: ' -"' ,__,(:_ '--C 0'1{ ·:-_::·· ...;._____ ____________ _ -~Q ELtvATION PLAN LAYOUT 1 DETECTABLE WARNING PATl'ERN DETAIL NOTES 1. PLACEMENT OF GRATINGS, ACCESS COVERS ANO OTHER APPURTENANCES SHALL NOT BE LOCATED ON CURB RAMPS, LANDINGS AND GUTIERS WITHIN THE PEDESTRIAN ACCESS ROUTE. (2) RAMPS SHALL BE TEXTURED USING TRUNCATED DOME PATIERN (SEE OETAIL THIS PAGE). DETECTABLE WARNING PATIERN SHALL BE YELLOW IN COMPLIANCE WITH WSOOT STANDARD SPECIFICATION 8-14.3(3) 3. RAMP CENTER LINE SHALL BE PERPENDICULAR TO OR RADIAL TO CURB RETURNS UNLESS OTHERWISE APPROVED BY THE COUNTY ROAD ENGINEER. 4. RAMPS SHALL BE CONSTRUCTED AT CORRESPONDING SIDEWALK LOCATIONS ON OPPOSITE SIDE OF STREETS WHEN RAMPS ARE CONSTRUCTED ON ONE SIDE OF STREET. SEE FIG. 3-D1 D. @ LANDING SHALL BE MINIMUM 4 X 4'. @ CURB RAMP IA MUST BE INSTALLED UNLESS OTHERWISE APPROVED. 7. SEE FIGURE 3-001 FOR CURB AND SIDEWALK JOINT PLACEMENT. 1. HANDICAP RAMP STREET TREE NOTES: TREES SHALL GENERALLY BE PLANTED BACK OF THE SIDEWALK. PLANTING STRIPS WILL BE APPROVED ONLY AS PART OF A LANDSCAPING PLAN IN WHICH PLANT MAINTENANCE, COMPATIBILITY WITH UTILITIES, AND TRAFFIC SAFETY ARE DULY CONSIDERED. NOTE 1.-~~ VERTICAL CURB LINE STREET TREE NOTES: STREET TREE 1. TREES TO BE PLANTED AT APPROX. 40' ON CENTER, WITH ADJUSTMENTS FOR UTILITY FIXTURES AND MAILBOXES. 2. HOMEOWNERS SHALL BE RESPONSIBLE FOR TREE MAINTENANCE FOR TREES WITHIN OR ABUTTING LOTS. 3. STREET TREES SHALL BE: l-i'R4)< DCCAW-A/\L-\:5 ( WcSrE.e.N Li'>f'Q{) LOCATE 5' BEHIND THE SIDEWALK (OR CURB, IF NO SIDEWALK) AT INTERSECTION 2. STANDARDS 3. IF PLANTING STRIPS ARE APPROVED: A. MIN. DISTANCE FROM CENTER OF ANY TREE TO NEAREST EDGE OF VERTICAL CURB SHALL BE 4 FEET. B. TREES SHALL BE STAKED IN A fAANNER NOT TO OBSTRUCT SIDEWALK TRAFFIC. C. IN CASE OF BLOCK-OUTS, MIN. CLEAR SIDEWALK WIDTH SHALL BE 5 FEET IN RESIDENTIAL OR 8 FEET IN BUSINESS DISTRICTS. ON BUS ROUTES, PLANS SHALL BE COORDINATED WITH METRO SERVICE PLANNING. PHONE 684-1622. B SID£ VIEW TRENCH X-SECTION NTS 1 2' o" 2'-0" 1 r-·--· 1 J Cl 1' C::J_:_ <o 6" FACE OF VERTICAL CURB PLAN VIEW NEIGHBORHOOD DELIVERY &: COLLECnoN BOX UNIT (N.D. C.8.U.) INSTALL AVON NOT TO SCALE slope- S700 sq. ft. > 700 sq. ft. PLAN VIEW OF ROOF NTS /mall catch basin or yard drain rW 2'x10' , ~ lJ level trenches Type I l - ~ ! - CB slandard dispersion trench w/ no1ched grade boc:rd lenglh 10' per 700 sq. tt. of roof area, see Figure 4.2.2.C of 1he Surface Water Design Manual INDIV. LOT DOlVNSPO'UT DISPERSAL TRENCII ' ~ •'<) I 'l- ([J i. 0 0 0 ' r, ''" 0 0 0 ' ,:, t<")' I -") ! " I _J L'......'.__,_~ ' ,. -,• <o ' ' I --' . • ' ,, ---- 1'-6" I FRONT VIEW r.J <:a N 0 .... ~ 0 a VJ r-C>') oo __j >-1 King County Deportment of Development and Environmental Services APPROVAL FOR SITE CONSTRUCTION - --Review Engineer ENGRCOMP Date Senior Engineer ENGRCOMP Date DEVELOPMENT ENGINEER APPROVAL Date Comments: ~ "'< ~ ~ • en ' "'< • ~ • J:.'.:1 __ , - REVISIONS: REV. PER CTY. OMMENTs'f0::-.'--,1'-'---0---1_ , __________ _ (j z -er w w z (j z w er w (j w § <l z ~ -) E... ~ h ~ ~ (/J 0 f<i ~ tr:: ~ i;..; ~ k1 trj ..q i::i ..., 8 E-l <o 0 ~ 0 -. ~ "' ~ "' ~ E-,i ~ ~ -. b ~ "' 0 t) w -, 0 fr' !L "' b <o°' ~o°' ~ o<n , <o I 1::1 0) "' (.j ~ "";:j-; ~ • (0 ~ . ;:,: ..q I":--._ "'-' ~) ~ 0 -<:I! ~, ~ ·,- ;;) '-' ~ .., ::,_ "<I • '-i ~ ,_c ~ o~< ~ kl . ~ tr: Q.., I'-' z <( t) ::J 0. 0. <( DATE: 31'16/07 SCALE: 1" = 30' DESIGfl BY: JJJ ---- DRWN. BY: JJJ APP. BY: FILE No. 3 SHEET OF _1-__ -_'JI~--· --~ .~----- ,-----------------~-------------------------------· --------------~--- A PORTION OF THE SW 1/4 OF SECTION 29, TWP. 23 N,, RGE. 4 E., W.M. REVISIONS: EROSION AND SEDIMENTATION CONTROL NOTES 1. Approval of this erosion and sedimentation control (ESC) plan does not constitute an approval of permane11t road or drainage design (e.g. size and location of roads, pipes, res\ric\ors, channels, retention facilities, utilities, elc.). z. The implementation of these ESC plans and the construction, maintenance, replacement, and upgrading of these ESC facilities is the responsibility of the applican\/ESC supervisor until all construction is approved. 3. The boundaries of the clearing limits shown on this plan shall be clearly flagged by a continuous length of survey tape (or fencing, if required) prior to construction. During the construction period, no disturbance beyond the clearing limits shall be permitted. The clearing limits shall be maintained by the applicant/ESC supervisor for the duration of construction. 4. The ESC facilities shown on this plan must be constructed prior to or in conjunction with all clearing and grading so as to ensure \ha\ the transport of sediment to surface waters, drainage systems, and adjacent properties is minimized. 5. The ESC facilities shown on this plan are the minimum requirements for anticipated site conditions. During the construction period, these ESC facilities shall be upgraded as needed for unexpected storm events and modified to account for changing site conditions (e.g. additional sump pumps, relocation of ditches and silt fences, etc.). 6. The ESC facilities shall be inspected daily by the applicant/ESC supervisor and maintained to ensure continued proper functioning. Written records shall be kept of weekly reviews of the ESC facilities during the wet season (Oct. 1 to April 30) and of monthly reviews during the dry season (May 1 to Sept. 30). 7. Any areas of exposed soils, including roadway embankments, that will not be disturbed for two days durin9 the season or seven days during the dry season shall be immediately stabilized with the approved ESC methods (e.g., seeding, mulching, plastic covering, etc.). wet 8. Any area needing ESC measures, not requiring immediate attention, shall be addressed w'i\hin fifteen (15) days. 9. The ESC facilities on inactive sites shall be inspected and maintained a minimum of once a month or within 48 hours following a storm event. 10. At no time shall more than one (1) foot basins and conveyance lines shall be cleaned water into the downstream system. of sediment be allowed to accumulate within a catch basin. All catch prior to paving. The cleaning operation shall no\ flush sedimen I-laden 11. Stabilized construction entrances and roads shall be installed at the beginning of construction and maintained for the duration of the project. Additional measures, such as wash pads, may be required to ensure that all paved areas are kept clean for the duration of the project. 12. Any permanent flow control facility used as a temporary settling basin shall be modified with the necessary erosion control measures and shall provide adequate storage capacity. If the facility is to function ultimately as an infiltration system, the temporary facility must be graded so that the bottom and sides are at least three feet above the final grade of the permanent facility. 13. Where straw mulch far temporary erosion control is required, it shall be applied at a minimum thickness of 2 to 3 inches. 14. Prior to the beginning of the wet season (Oct. 1), all disturbed areas shall be reviewed to identify which ones can be seeded in preparation for the winter rains. Disturbed areas shall be seeded within one week of the beginning of the wet season, A sketch map of those areas \o be seeded and those areas to remain uncovered shall be submitted to the DDES jn,;pector. The DDES inspector can require seeding of additional areas in order to protect surface waters, adjacent properties, or drainage facilities. CATCH BASIN INSE_RT MAIN TE,\JAN<;:E STAt\JDAROS 1. A\JY ACCUMULATED SEDIMENT ON OF, AROUND THE FILTER FABRIC PROTECTIOI, SHALL BE REMOVED IMlvlEDIATEL Y. SC:Dll,IENT SH1\LL NOT BE REMOVED WITH WATER, A-ND J1LL SEDl~,1ENT 1,!UST BE OF AS FILL ON SITE OR HAULED OFF SITE. DISPOS[D 2. ANY SEDIMENT IN THE CATCH BAS:N INSERT SHALL BE REMOVED WH:C:~I THE SEOl~AENT HAS FILLED ONE-THIF10 OF THE AVAILABLE STORAGE. THE FILTER MEDIA FOR THE INSERT SHA'-~ BE CLE./\,NED Of, REPLACED AT LEAST MO~I THL Y 3. REGULAR VIAINTENANCE IS CRITICAL FOFl BOTH FORMS OF CATCH BASINS PROTECTION. UNLIKE 1VIANY FORVIS OF PROTECTION THAT G:RADUALL Y, CATCH BASl~I PF,OTECTION WILL FAIL SUDDE~IL Y AND COMPLETELY IF NOT HAINTAIN:cD PROPEF1LY FAIL GRATE\ /-STAND.ARD STRENGTH \ FILTER FI\BF\IC TEMP, CB INLET PRDTECT!DN F[LTER 'SOCKS'. ON EXfS'ffNG CATCH BAS[NS. (SEE DET.) ') / . S\\\(\~~~~~~~~%~~ -_ ~~--~. v~~jf!!;~}#~'Jjh'Y{!~f)';;lli ·\\(\%~~~~~\) ·'~ IFILTERED V((J/;~//jl!!'1!/-iff-j:':;jj!/)Y 1 •· ·,y\:>1·. ~ WATER -,, .<\?l,f!;--1/~;:-.::.,---,.;11,,1l"'> CATCH 1'. I '-,,~ " NOTE ONLY TO BE USED __/ WHERE PONDING OF WATER ~CA.TCH ABOVE THE CATCH BASl~I WILL NOT CAUSE TRAfTiC PROBLEMS AND WHERE 0\/ERFI_OW WILL ,\JOR RESULT IN EROSION OF Sl_OPES BASII\J BASIN INLET FILTER N.T.S. LEGEND CLEARING LIMITS TEMP CB FIL T£R PRDPDS£JJ CDNTDUR EXIST. TR££ EXIST, TREE TD BE REMOVED SSMH RIM=376.5 \'/1.7 <Xe»:-< (3) 10" vv,, PINES XX 8" ~Plum REMOVE BLOCK 4 AKER'S FARMS ND. 5 27 VOL 40, PAGE LDT 12 130.01' 300.01' (CALC) I ·-- I GRAPHIC SCALE CONSTRUC'110N SEQUENC'E 1. Arrange and attend a preconstruction meeting with King County DDES Inspections Unit. Call (206) 296-6642. ' 2. Flag clearing limits and easements. Flag property lines. 3. Post sign with name and phone number of ESC supervisor. 4. Flag all trees that to be saved. 5. Grade and install quarry spall construction entrance. 6. Install silt fencing as shown on the plans. 7. Maintain erosion control measures in accordance with King County standards and manufacturer's recommendations. 8. Relocate surface water controls or erosion control measures, or install new measures so that as site conditions change the erosion and sediment control is always in accordance with the King County Erosion and Sediment Control Standards. 9. Cover all areas that will be unworked for more than seven days during the dry season or two days during the wet season with straw, wood fiber mulch, compost, plastic sheeting or equivalent. 10. Stabilize all areas within seven days of reaching final grade. 11. Seed or sod any areas to remain unworked for more than 30 days. 12. Upon completion of the project, stabilize all disturbed areas and remove BMPs upon approval of the Inspector. L_OT 13 co (\J (I\ 0 -i _J I I EX HOUSE I I :,; 1..--- ' -"T King County Deportment of Development and Environmental Services APPROVAL FOR SITE CONSTRUCTION Review Engineer EN GR COMP Date Senior Engineer ENGRCOMP Date 20 O 10 20 40 80 ~--=-=.· .1 !li'fJ!)Mj . 1:i111i•··•"'l1\lll.,.. .. 1"""AA,~ ~L_.....___....__.._ .... __ ,wrr:r:rrr1t-~~ .. Jl----~~ ( IN F'EET ) inch = 20 ft. DEVELOPMENT Cornments: UJGINEER APPROVAL Dote REV. PE CTY. ~OMMENTS 16=1-o- "' u w -, 0 "' "- "' z <( u :J "-"-<( (j z 0:: w w z ('.) z w E-, ~ ~ t--4 ~ ~ 0 E>i ~~ Cr.) .£:1 ,j.> E-, ;g C ·-, ~ 'st< ~ Cl C'J l'-.... ~ ~ Cj C'l ~ (C 0, ~ e:, 0, ~ c:, ~ • <:o I Fcl 0, ~ Cj ::.: 'st< '<ti • <.o ~ ~ ~-, .q lD ~ Q "C\l to~~ ~ ........ r,q • ""'~ .. o ~ a ,<'.; ~~~ ~ ll; c3 ~ ~ Cl (;..) ~ Cl) ~ ~ .. , Cl) 0 ~ ~ 8"i N DATE: 3/16/07 SCALE: 1" = 30' DESIGN BY: _J,JL__ DRWN. BY: JJJ APP. BY: FILE No. SHEET 4 OF :1