Loading...
HomeMy WebLinkAboutSEA Logan Ave_Carpenter's Union-RFZD_20180228PROPERTY OWNER: SEE SHEET SV-1.0 FOR LEGAL DESCRIPTION. LEGAL DESCRIPTION APPROVED BY CONSTRUCTION MANAGER DATE SIGNATURE PROJECT MANAGER SITE ACQUISITION ZONING APPROVAL / SIGN OFF PROJECT CONTACT LIST PROJECT INFORMATION RF REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED FROM VERIZON WIRELESS OFFICE: x HEAD EAST TOWARD 158TH AVE SE x TURN RIGHT ONTO 158TH AVE SE x TURN RIGHT ONTO SE EASTGATE WAY x TURN LEFT ONTO THE I-90 W RAMP TO SEATTLE x KEEP LEFT, FOLLOW SIGNS FOR I-90 W/SEATTLE AND MERGE ONTO I-90 W x MERGE ONTO I-90 W x USE THE RIGHT 2 LANES TO TAKE EXIT 10 FOR INTERSTATE 405 S TOWARD RENTON x MERGE ONTO I-405 S x TAKE EXIT 5 TOWARD WA-900 E/PARK AVENUE NORTH/SUNSET BLVD N.E x TURN RIGHT ONTO NE PARK DR (SIGNS FOR PARK AVENUE N) x CONTINUE STRAIGHT ONTO LOGAN AVE N x TURN LEFT ONTO N 3RD ST x TURN RIGHT AT THE 1ST CROSS STREET ONTO BURNETT AVE N x DESTINATION WILL BE ON THE RIGHT DRIVING DIRECTIONS VERIZON WIRELESS PROPOSES TO CONSTRUCT AN UNMANNED TELECOMMUNICATIONS FACILITY CONSISTING OF (6) PANEL ANTENNAS & (1) MICROWAVE MOUNTED ON A 59.9' MONOPINE, AND EQUIPMENT PAD WITH GENERATOR WITHIN A FENCED LEASE AREA. MICROWAVE (NEW) TELEPHONE:POWER: PUGET SOUND ENERGY PHONE: (888) 225-5773 ZONING CLASSIFICATION: CODE INFORMATION: UB (URBAN CENTER) BUILDING CODE:IBC 2015 CONSTRUCTION TYPE:IIB OCCUPANCY:U, S-2 JURISDICTION:CITY OF RENTON PROPOSED BUILDING USE:UNMANNED TELECOM LATITUDE: SITE LOCATION (NAD83): ƒ 1 LONGITUDE:ƒ : TOP OF STRUCTURE:93.10' AMSL BASE OF STRUCTURE:33.20' AMSL 292 SF PROJECT LEASE AREA: 1823059150 PARCEL NUMBER: 0.93 ACRES AREA OF PARCEL: 0 SF NEW IMPERVIOUS AREA: 1.PARKING REQUIREMENTS ARE UNCHANGED. 2.TRAFFIC IS UNAFFECTED. 3.SIGNAGE IS UNAFFECTED. GENERAL INFORMATION: PROJECT DESCRIPTION: 59.9' AGL 0.0' AGL ƒ1 ƒ: VICINITY MAP NOT TO SCALE GENERAL LOCATION MAP NOT TO SCALE PROJECT PROJECT TITLE SHEET T-1.0 LANDLORD 231 BURNETT AVE N RENTON, WA 98057 SEA LOGAN AVE - CARPENTER'S UNION DRAWING INDEX DWG NO.DESCRIPTION T-1.0 TITLE SHEET SV-1.0 CIVIL SURVEY A-1.0 SITE PLAN A-2.0 ENLARGED SITE PLAN A-3.0 ELEVATION PACIFIC NORTHWEST REGIONAL COUNCIL OF CARPENTERS 15 LOGAN AVE N RENTON,WA 98055 APPLICANT: VERIZON WIRELESS 3245 158TH AVENUE SE BELLEVUE, WA 98008 PROJECT ARCHITECT: LDC, INC. CONTACT: RICHARD B. HALL, AIA PHONE: (425) 806-1869 EMAIL: rhall@ldccorp.com PROJECT CONSULTANT: LDC, INC. CONTACT: RICK CARDOZA PHONE: (253) 218-9017 EMAIL: rcardoza@ldccorp.com UTILITY COMPANIES THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO VERIZON WIRELESS SERVICES IS STRICTLY PROHIBITED. PROPRIETARY INFORMATION DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWINGS ARE SUPERSEDED BY THE LATEST REVISION. LDC TAKES NO RESPONSIBILITY FOR ADEQUACY OF TOWER MOUNTS FOR EXISTING OR PROPOSED LOADING. CONTRACTOR AND MOUNT MANUFACTURER TAKE FULL RESPONSIBILITY FOR MOUNTING PRODUCTS USED & THEIR ADEQUACY. MOUNTS SHOWN IN DRAWINGS ARE FOR ILLUSTRATIVE PURPOSES ONLY. DISCLAIMERS SHEET NUMBER SUBMITTALS DATE: DRAWN BY: CHECKED BY: SITE DESCRIPTION BYDATE SHEET TITLE REV APPROVAL STAMP Structural Engineering Architectural www.LDCcorp.com 20210 142nd Ave NE Woodinville, WA 98072 THE CIVIL ENGINEERING GROUP Fx. 425.482.2893 Ph. 425.806.1869 Survey 8828 DATE: DRAWN BY: CHECKED BY: SEA LOGAN AVE - CARPENTER'S UNION 231 BURNETT AVE N RENTON, WA 98057 11-21-17 JDM RBH 1 11-21-17 PRELIMINARY ZONING JDM 2 12-20-17 RPZD: CHANGE TOWER KTL 3 12-21-17 RPZD: NEW IT DIAGRAM ENS 4 12-22-17 FINAL ZONING ENS 5 2-21-18 RFZD: NEW TOWER LOCATION ENS 6 2-28-18 RFZD: CLIENT COMMENTS RJG LDC, INC. CONTACT: MICHAEL MERRITT, PLS, CFedS PHONE: (425) 806-1869 EMAIL: michaelm@ldccorp.com PROJECT SURVEYOR: CIVIL SURVEY SV-1.0 SHEET NUMBER REVISIONS DATE: DRAWN BY: CHECKED BY: SITE DESCRIPTION BYDATE SHEET TITLE REV Residential Infrastructure Commercial www.LDCcorp.com 20210 142ND AVE NE Woodinville, WA 98072 THE CIVIL ENGINEERING GROUP Fx. 425.482.2893 Ph. 425.806.1869 Telecom SEA LOGAN AVE - CARPENTER'S UNION 231 BURNETT AVE N RENTON, WA 98057 10-20-2017 NSY MRM PROJECT 1 ZONING: ADJACENT ZONING: ZONING MAP NOT TO SCALE SITE PLAN 22"x34" SCALE: 1" = 20'11"x17" SCALE: 1" = 40' PROJECT PROPOSED VERIZON WIRELESS FENCED LEASE AREA EXISTING SITE ACCESS SITE PLAN A-1.0 UB (URBAN CENTER) UB (URBAN CENTER) SHEET NUMBER SUBMITTALS DATE: DRAWN BY: CHECKED BY: SITE DESCRIPTION BYDATE SHEET TITLE REV APPROVAL STAMP Structural Engineering Architectural www.LDCcorp.com 20210 142nd Ave NE Woodinville, WA 98072 THE CIVIL ENGINEERING GROUP Fx. 425.482.2893 Ph. 425.806.1869 Survey 8828 DATE: DRAWN BY: CHECKED BY: SEA LOGAN AVE - CARPENTER'S UNION 231 BURNETT AVE N RENTON, WA 98057 11-21-17 JDM RBH 1 11-21-17 PRELIMINARY ZONING JDM 2 12-20-17 RPZD: CHANGE TOWER KTL 3 12-21-17 RPZD: NEW IT DIAGRAM ENS 4 12-22-17 FINAL ZONING ENS 5 2-21-18 RFZD: NEW TOWER LOCATION ENS 6 2-28-18 RFZD: CLIENT COMMENTS RJG PROPOSED VERIZON WIRELESS ANTENNAS & MICROWAVE MOUNTED ON A 59.9' MONOPINE ADJACENT ZONING: R6 (RESIDENTIAL 6 DU/ AC) ADJACENT ZONING: R10 (RESIDENTIAL 10 DU/AC) IM UC R10 CD R6 CV 1 ADJACENT ZONING: R10 (RESIDENTIAL 10 DU/AC) PROPOSED VERIZON WIRELESS 20' ACCESS EASEMENT 12' TOWER SETBACK 13' TOWER SETBACK 181' TOWER SETBACK 5'- 1 " 1 1 ENLARGED SITE PLAN 22"x34" SCALE: 3/8" = 1'-0"11"x17" SCALE: 3/16" = 1'-0" ENLARGED SITE PLAN A-2.0 SHEET NUMBER SUBMITTALS DATE: DRAWN BY: CHECKED BY: SITE DESCRIPTION BYDATE SHEET TITLE REV APPROVAL STAMP Structural Engineering Architectural www.LDCcorp.com 20210 142nd Ave NE Woodinville, WA 98072 THE CIVIL ENGINEERING GROUP Fx. 425.482.2893 Ph. 425.806.1869 Survey 8828 DATE: DRAWN BY: CHECKED BY: SEA LOGAN AVE - CARPENTER'S UNION 231 BURNETT AVE N RENTON, WA 98057 11-21-17 JDM RBH 1 11-21-17 PRELIMINARY ZONING JDM 2 12-20-17 RPZD: CHANGE TOWER KTL 3 12-21-17 RPZD: NEW IT DIAGRAM ENS 4 12-22-17 FINAL ZONING ENS 5 2-21-18 RFZD: NEW TOWER LOCATION ENS 6 2-28-18 RFZD: CLIENT COMMENTS RJG CONSTRUCTION PLAN KEYED NOTES 1.VERIFY ANTENNA MODEL, TIP HEIGHT & AZIMUTHS. 2.ANALYSIS OF FOUNDATION & TOWER SHALL BE PERFORMED BY OTHERS & STAMPED BY A LICENSED STRUCTURAL ENGINEER. TOWER SHALL BE PAINTED TO RESEMBLE BARK. 3.ALL PROPOSED ANTENNAS, MOUNTING HARDWARE, AND CABLING SHALL BE PAINTED DARK GREEN TO MATCH MONOPINE BRANCHES AND ADD CAMOUFLAGE COVERS OVER PANEL ANTENNAS. SITE NOTES PROPOSED VERIZON WIRELESS LED FLOODLIGHT W/ TIMER SWITCH (2 TOTAL). PROPOSED VERIZON WIRELESS POWER & FIBER ROUTING (DESIGN PENDING). PROPOSED VERIZON WIRELESS 8'-0" TALL CHAIN LINK FENCE W/ OPAQUE SCREEN. STRUCTURAL PENDING. PROPOSED VERIZON WIRELESS 10'-0" WIDE DOUBLE SWING CHAIN LINK ACCESS GATE W/ OPAQUE SCREEN AND LOCKING MECHANISM. VZW SIGNAGE MOUNTED TO GATE. PROPOSED VERIZON WIRELESS HYBRID CABLE TO ANTENNAS (2 TOTAL). PROPOSED VERIZON WIRELESS 9'-0" TALL PEDESTAL MOUNTED ICE BRIDGE W/ 7'-0" CLEAR BELOW COAX SUPPORT. PROPOSED VERIZON WIRELESS CONCRETE EQUIPMENT PAD. STRUCTURAL PENDING. PROPOSED VERIZON WIRELESS FLUSH T-ARM ANTENNA MOUNT (1 TOTAL). SEE SITE NOTE 3. PROPOSED VERIZON WIRELESS PANEL ANTENNA (TYP 2 PER SECTOR, 6 TOTAL). SEE SITE NOTE 3. PROPOSED VERIZON WIRELESS GPS ANTENNA (1 TOTAL). 352326('9(5,=21:,5(/(66   ‘0,&52:$9( W/ ODU & MOUNT. SEE SITE NOTE 3. 6,7(72%(),//(':,7+2)‘&586+('52&.::((' BARRIER ON 95% COMPACTED FILL. PROPOSED VERIZON WIRELESS TELCO/ FIBER ENCLOSURE. PROPOSED VERIZON WIRELESS ILC ENCLOSURE. PROPOSED VERIZON WIRELESS RING MOUNT W/ 8" STAND-OFF ARM (1 TOTAL). SEE SITE NOTE 3. PROPOSED VERIZON WIRELESS RAYCAP DISTRIBUTION OVP 12 BOX (1 TOTAL). PROPOSED 59.9' MONOPINE. ENGINEERED BY OTHERS. SEE SITE NOTE 2. PROPOSED VERIZON WIRELESS 25KW DIESEL GENERATOR. PROPOSED VERIZON WIRELESS WP METER/MAIN W/ METER BASE AND DISCONNECT. PROPOSED VERIZON WIRELESS PDU/BATTERY CABINET (1 TOTAL). PROPOSED VERIZON WIRELESS LEASE AREA. PROPOSED VERIZON WIRELESS (2) RADIO CABINET WITH (2) PRE-INSTALLED RAYCAP OVP DEVICES. PROPOSED VERIZON WIRELESS RRUS 8843 UNIT (TYP 1 PER SECTOR, 3 TOTAL). PROPOSED VERIZON WIRELESS RRUS 4449 UNIT (TYP 1 PER SECTOR, 3 TOTAL). PROPOSED VERIZON WIRELESS NOISE BARRIER DESIGN (SEE NOISE BARRIER DESIGN NOTES). 1 2 3 4 5 6 8 9 10 11 12 14 15 19 20 21 22 23 24 25 27 28 29 30 31 SECT O R 3 : 245 ƒ SE C T O R 1 : 5 ƒ EXISTING LANDSCAPING EXISTING PARKING LINES, TYP (TO REMAIN) EXISTING PARKING LOT PR O P O S E D V E R I Z O N W I R E L E S S 1 6 ' - 6 " F E N C E D L E A S E A R E A PR O P O S E D V E R I Z O N W I R E L E S S 10 ' - 0 " W I D E D O U B L E S W I N G G A T E 2'- 0 " 6" PR O P O S E D V E R I Z O N W I R E L E S S 1 5 ' - 0 " E Q U I P M E N T P A D PROPOSE D V E R I Z O N W I R E L E S S 13'-5" FEN C E D L E A S E A R E A W I T H N O I S E B A R R I E R P R O P O S E D V E R I Z O N W I R E L E S S 1 4 ' - 1 1 " F E N C E D L E A S E A R E A EXISTING CURB, TYP (TO REMAIN) 2'-2" (FUT) PR O P O S E D V E R I Z O N W I R E L E S S 2 0 ' - 0 " A C C E S S E A S E M E N T x VERIZON WIRELESS SHALL UTILIZE (2) EXISTING PARKING SPOTS PRO P O S E D VERI Z O N W I R E L E S S 8'-4" E Q U I P M E N T P A D PR O P O S E D V E R I Z O N W I R E L E S S 2 3 ' - 9 " L E A S E A R E A 5' - 3 " 6" 6" 6" 1'- 2 " 1'-3" 2'-2" 2'-1" 3'-8" 1'-3" 7" PR O P O S E D VE R I Z O N W I R E L E S S 6'- 4 " C H A I N L I N K FE N C E 2'- 0 " 5'- 4 " MW : TB D ƒ 4' - 1 0 " 3'-0 " S E C T O R 2 : 12 5 ƒ 2ENLARGED TOWER PLAN 22"x34" SCALE: 1/4" = 1'-0"11"x17" SCALE: 1/8" = 1'-0" EQ , T Y P 3'-0 " 1. NOISE BARRIER 8 FEET TALL. 2. NOISE BARRIER OF A SOLID MATERIAL THAT HAS A SURFACE MASS OF 2 LBS/ SQ FT INCLUDING: x LAYER OF 3/4" EXTERIOR GRADE PLYWOOD. x (1) LAYER OF 16-GA SHEET METAL APPROXIMATELY 2 LBS/ SQ FT. x ADDITIONAL MATERIALS TO THE OUTSIDE OF THAT BARRIER, SUCH AS FENCE BOARD OR SIDING FOR AESTHETIC PURPOSES. 3. INSIDE OF THE NOISE BARRIER (SIDE FACING CABINETS) LINED WITH: x SOUND ABSORBING MATERIAL THAT HAS A MINIMUM NRC RATING OF 0.50. x WEATHER-RESISTANT MATERIALS THAT MEET THIS REQUIREMENT INCLUDE 2-INCH THICK EXTERIOR x GRADE F-SORF (FORREST SOUND PRODUCTS (425) 881-1111 (OR EQUAL). 4. NO AIR GAPS BETWEEN JOINTS IN THE BARRIER MATERIAL: GAPS MUST BE SEALED WITH A NON-HARDENING ACOUSTICAL SEALANT. x AIR-TIGHT TO CREATE A CONTINUOUS ENVELOPE. PR O P O S E D V E R I Z O N W I R E L E S S 1 5 ' - 9 " WO O D F E N C E W I T H N O I S E B A R R I E R 14 EXISTING SITE ACCESS 1 1 9 15 20 5 4 26 24 28 28 27 8 22 25 23 19 1 9 10 21 2 1 2 30 11 29 6 12 (BELOW)3 19 31 9 31 PROPOSED MONOPINE DRIP LINE 6'-0" S E T B A C K FRO M P R O P L I N E 1PROPOSED NORTHWEST ELEVATION (LOOKING SOUTHEAST) 22"x34" SCALE: 3/16" = 1'-0"11"x17" SCALE: 3/32" = 1'-0" 0.0' AGL ELEVATION A-3.0 SHEET NUMBER SUBMITTALS DATE: DRAWN BY: CHECKED BY: SITE DESCRIPTION BYDATE SHEET TITLE REV APPROVAL STAMP Structural Engineering Architectural www.LDCcorp.com 20210 142nd Ave NE Woodinville, WA 98072 THE CIVIL ENGINEERING GROUP Fx. 425.482.2893 Ph. 425.806.1869 Survey 8828 DATE: DRAWN BY: CHECKED BY: SEA LOGAN AVE - CARPENTER'S UNION 231 BURNETT AVE N RENTON, WA 98057 11-21-17 JDM RBH 1 11-21-17 PRELIMINARY ZONING JDM 2 12-20-17 RPZD: CHANGE TOWER KTL 3 12-21-17 RPZD: NEW IT DIAGRAM ENS 4 12-22-17 FINAL ZONING ENS 5 2-21-18 RFZD: NEW TOWER LOCATION ENS 6 2-28-18 RFZD: CLIENT COMMENTS RJG CONSTRUCTION PLAN KEYED NOTES 1.VERIFY ANTENNA MODEL, TIP HEIGHT & AZIMUTHS. 2.ANALYSIS OF FOUNDATION & TOWER SHALL BE PERFORMED BY OTHERS & STAMPED BY A LICENSED STRUCTURAL ENGINEER. TOWER SHALL BE PAINTED TO RESEMBLE BARK. 3.ALL PROPOSED ANTENNAS, MOUNTING HARDWARE, AND CABLING SHALL BE PAINTED DARK GREEN TO MATCH MONOPINE BRANCHES AND ADD CAMOUFLAGE COVERS OVER PANEL ANTENNAS. SITE NOTES PROPOSED VERIZON WIRELESS 8'-0" TALL CHAIN LINK FENCE W/ OPAQUE SCREEN. STRUCTURAL PENDING. PROPOSED VERIZON WIRELESS FLUSH T-ARM ANTENNA MOUNT (1 TOTAL). SEE SITE NOTE 3. PROPOSED VERIZON WIRELESS PANEL ANTENNA (TYP 2 PER SECTOR, 6 TOTAL). SEE SITE NOTE 3. PROPOSED VERIZON WIRELESS GPS ANTENNA (1 TOTAL). 352326('9(5,=21:,5(/(66   ‘0,&52:$9( W/ ODU & MOUNT. SEE SITE NOTE 3. PROPOSED VERIZON WIRELESS RING MOUNT W/ 8" STAND-OFF ARM (1 TOTAL). SEE SITE NOTE 3. PROPOSED VERIZON WIRELESS RAYCAP DISTRIBUTION OVP 12 BOX (1 TOTAL). PROPOSED 59.9' MONOPINE. ENGINEERED BY OTHERS. SEE SITE NOTE 2. PROPOSED VERIZON WIRELESS 25KW DIESEL GENERATOR. PROPOSED VERIZON WIRELESS PDU/BATTERY CABINET (1 TOTAL). PROPOSED VERIZON WIRELESS (2) RADIO CABINET WITH (2) PRE-INSTALLED RAYCAP OVP DEVICES. PROPOSED VERIZON WIRELESS RRUS 8843 UNIT (TYP 1 PER SECTOR, 3 TOTAL). PROPOSED VERIZON WIRELESS RRUS 4449 UNIT (TYP 1 PER SECTOR, 3 TOTAL). 3 4 5 6 9 11 12 20 24 27 28 29 30 FINISH GRADE RAD CENTER OF PROPOSED VERIZON WIRELESS MICROWAVE 53.9' AGL PROPOSED VERIZON WIRELESS 23'-9" FENCED LEASE AREA EXISTING TREE, TYP EXISTING BUILDING (BEYOND) 4 TOP OF PROPOSED MONOPINE 54.9' AGL TIP HEIGHT OF PROPOSED VERIZON WIRELESS ANTENNAS 49.9' AGL 11 12 15 2027 9 24 28 TOP OF PROPOSED MONOPINE BRANCHES 59.9' AGL 6 3 30 29 5