HomeMy WebLinkAboutP_zoning site plan & elevations_171113_v1PROJECT SUMMARY
PROJECT DESCRIPTION
VICINITY MAP
DRIVING DIRECTIONS
CODE COMPLIANCE
T-1 TITLE SHEET
A-2
OVERALL SITE PLAN / ENLARGED ROOF PLAN
ENLARGED RF PLANS
A-1
NOT TO SCALE
IMAGE SOURCE: GOOGLE MAPS
PROJECT TEAM SHEET DESCRIPTION
SIGNATURE BLOCK
WO ADMINISTRATOR:
EQUIPMENT COORDINATOR:
THE FOLLOWING PARTIES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS & AUTHORIZE THE
SUBCONTRACTOR TO PROCEED WITH CONSTRUCTION DESCRIBED HEREIN. ALL DOCUMENTS ARE
SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT & MAY IMPOSE CHANGES OR
MODIFICATIONS.
PROJECT ADMINISTRATOR:
DISCIPLINE:
RF ENGINEER:
TELCO COORDINATOR:
SITE ACQUISITION MANAGER:
PARABOLIC:
CONSTRUCTION MANAGER:
SIGNATURE:DATE:
SEA CLASSICS
2003 MAPLE VALLEY HIGHWAY
RENTON, WA 98055
KING COUNTY
ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE
CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING
AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING
TO THE LATEST EDITIONS OF THE FOLLOWING CODES.
SEA CLASSICS
2003 MAPLE VALLEY
HIGHWAY
RENTON, WA 98055
KING COUNTY
DRAWN BY:CHECKED BY:
SHEET TITLE:
SHEET NUMBER:REV.:
DATE
PROJECT INFORMATION:
REVISION DESCRIPTIONREV.
DAP PD
THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY, LLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY, LLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD.
2
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO VERIZON
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO VERIZON IS
STRICTLY PROHIBITED
F R O M Z E R O IOT N F I IN G Y
T-1
90% ZONING DRAWINGS009/8/17
REVISED PRELIM. ZONING DRAWINGS109/12/17
100% ZONING DRAWINGS11/13/172
6+6.'
5*''6
ELEVATIONS
LEGAL DESCRIPTION:SEE SHEET SV-1
APN:172305-9103
COUNTY: KING
JURISDICTION: CITY OF RENTON
CURRENT ZONING:&25±&200(5&,$/2)),&(5(6,'(17,$/
PLANNING
APPLICANT'S REPRESENTATIVE
LESSEE
COMPANY:VERIZON
ADDRESS:3245 158TH AVE SE
CITY, STATE, ZIP:BELLEVUE, WA 98008
CONTACT:MICHAEL CUNNINGHAM
PHONE: (713) 201-7503
EMAIL: michael.cunningham2@verizonwireless.com
SITE AQUISITION
COMPANY: MD7
ADDRESS: 9725 THIRD AVE NE, SUITE 410
CITY, STATE, ZIP: SEATTLE, WA 98115
CONTACT: BECKY TODD
PHONE:(206) 802-4321
E-MAIL: btodd@md7.com
PROPERTY INFORMATION:
PROFESSIONAL OF RECORD
COMPANY:INFINIGY ENGINEERING
ADDRESS:50 116TH AVE SE, SUITE 210
CITY, STATE, ZIP:BELLEVUE, WA 98004
CONTACT:PAUL DANNEBERG
PHONE:(425) 201-4215 x1603
E-MAIL:pdanneberg@infinigy.com
PROPERTY OWNER:
5+6'
IMPLEMENTATION CONTACT
COMPANY:VERIZON
ADDRESS: 3245 158TH AVE SE
CITY, STATE, ZIP: BELLEVUE, WA 98008
CONTACT: TRAVIS NICHOLS
PHONE: (425) 531-5224
COMPANY:RAMAC INC.
ADDRESS:
CITY, STATE, ZIP:
CONTACT:GREG JAMES
PHONE: 425-226-0309
COMPANY;MD7
ADDRESS: 9725 THIRD AVE NE, SUITE 410
CITY, STATE, ZIP: SEATTLE, WA 98115
CONTACT:CHRISTA KLUMB
PHONE: (425) 350-9095
E-MAIL:cklumb@md7.com
SITE SURVEYSV-1
N
1. 2015 INTERNATIONAL BUILDING CODE
2. 2014 NATIONAL ELECTRICAL CODE
3. 2015 INTERNATIONAL FIRE CODE
4. 2015 INTERNATIONAL MECHANICAL CODE
5. 2015 UNIFORM PLUMBING CODE
FROM VERIZON OFFICE (3245 158th Ave SE, Bellevue, WA 98008):
GET ON I-90 W 0.6 MI
HEAD SOUTH ON 158TH AVE SE 197 FT
TURN RIGHT ONTO SE EASTGATE WAY 0.1 MI
TURN LEFT ONTO THE I-90 W RAMP TO SEATTLE 0.2 MI
KEEP LEFT, FOLLOW SIGNS FOR I-90 W/SEATTLE AND MERGE ONTO I-90 W 0.2 MI
TAKE I-405 S TO WA-900/SUNSET BLVD N IN RENTON. TAKE EXIT 4 FROM I-405 S 7.9 MI
MERGE ONTO I-90 W 0.9 MI
USE THE RIGHT 2 LANES TO TAKE EXIT 10 FOR INTERSTATE 405 S TOWARD RENTON 0.8 MI
USE THE LEFT LANE TO MERGE ONTO I-405 S 0.2 MI
CONTINUE STRAIGHT TO STAY ON I-405 S 5.8 MI
TAKE EXIT 4 FOR WA-900 W TOWARD WA-169 S/RENTON/ENUMCLAW 0.2 MI
DRIVE TO WA-169 S 0.9 MI
MERGE ONTO WA-900/SUNSET BLVD N 0.4 MI
USE THE LEFT 2 LANES TO TURN LEFT ONTO WA-169 S 0.5 MI
DESTINATION WILL BE ON THE RIGHT
2003 MAPLE VALLEY HIGHWAY, RENTON, WA 98055
A-3
COMPANY;MD7
ADDRESS: 9725 THIRD AVE NE, SUITE 410
CITY, STATE, ZIP: SEATTLE, WA 98115
CONTACT:CHRISTA KLUMB
PHONE: (425) 350-9095
E-MAIL:cklumb@md7.com
CONSTRUCTION INFORMATION:
LAT / LONG COORDINATES:
AREA OF CONSTRUCTION:(48,30(17 $17(11$$5($64)7
TOTAL ACREAGE:$&5(6
TYPE OF CONSTRUCTION:II-B
OCCUPANCY GROUP:U
SEISMIC DESIGN CATEGORY:D
PROPOSED USE:UNMANNED TELECOMMUNICATIONS FACILITY
HANDICAP REQUIREMENTS: FACILITY IS UNMANNED AND NOT FOR HUMAN
HABITATION. HANDICAPPED ACCESS NOT REQUIRED.
LATITUDE:
LONGITUDE:
AMSL: 54' AMSL (NAVD '88)
VERIZON PROPOSES TO CONSTRUCT AN UNMANNED TELECOMMUNICATIONS INSTALLATION
CONSISTING OF: (4) PANEL ANTENNAS (2 PER SECTOR), (1) 2' MICROWAVE ANTENNA, (6) RRU'S,
& (2) OVP'S WITHIN NEW SCREEN ENCLOSURES ON THE ROOFTOP OF AN EXISTING BUILDING;
AND (2) EQUIPMENT RACKS & (2) OVP'S WITHIN AN EXISTING UNOCCUPIED OFFICE SPACE TO BE
CONVERTED TO AN EQUIPMENT ROOM WITHIN THE EXISTING BUILDING, WITH CABLING AS
NEEDED.
RECEIVED
01/02/2018
amorganroth
PLANNING DIVISION
145 SW 155th Street, Suite 102
Seattle, Washington 98166
Phone 206.244.4141
Fax 206.244.4455
1 inch = ft.
(IN FEET)
GRAPHIC SCALE
1 inch = ft. (11x17 SHEET)1020
FROM ZERO IOTNFIINGY
N
OVERALL SITE PLAN1 0"20'10'20'
22"x34" SCALE: 1" = 20'-0"
11"x17" SCALE: 1" = 40'-0"
SEA CLASSICS
2003 MAPLE VALLEY
HIGHWAY
RENTON, WA 98055
KING COUNTY
DRAWN BY:CHECKED BY:
SHEET TITLE:
SHEET NUMBER:REV.:
DATE
PROJECT INFORMATION:
REVISION DESCRIPTIONREV.
DAP PD
THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY, LLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY, LLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD.
2
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO VERIZON
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO VERIZON IS
STRICTLY PROHIBITED
F R O M Z E R O IOT N F I IN G Y
A-1
90% ZONING DRAWINGS009/8/17
REVISED PRELIM. ZONING DRAWINGS109/12/17
100% ZONING DRAWINGS11/13/172
18'4#..5+6'2.#0
'0.#4)'&411(2.#0
P
R
O
P
E
R
T
Y
L
I
N
E
M
A
P
L
E
V
A
L
L
E
Y
H
I
G
H
W
A
Y
EXISTING
BUILDING
NOTES:
1.SITE PLAN SHALL MEET ALL
ENGINEERING AND NPDES
REQUIREMENTS.
C
L
C
E
D
A
R
R
I
V
E
R
PR
O
P
E
R
T
Y
L
I
N
E
P
R
O
P
E
R
T
Y
L
I
N
E
P
R
O
P
E
R
T
Y
L
I
N
E
EXISTING
PARKING
EGR
E
S
S
ING
R
E
S
S
EXISTING
PARKING
EXISTING POWER VAULT,
PROPOSED VERIZON
POWER P.O.C.
EXISTING FIRE HYDRANT
PROPOSED
LEASE AREA
0"8'8'
22"x34" SCALE: 3/32" = 1'-0"
11"x17" SCALE: 3/64" = 1'-0"4'
N
EXISTING
ROOFTOP
PROPOSED VERIZON
8'-0"x4'-0"x8'-0" FRP
ENCLOSURE
2 ENLARGED ROOF PLAN
EXISTING VENT PIPE (TYP.)
EXISTING HVAC
EXISTING ROOF
DRAIN (TYP.)
EXISTING ROOF
ACCESS HATCH
EXISTING HVAC
PROPOSED
VERIZON
CABLE TRAY
8'-0
"
PRO
P
O
S
E
D
LEA
S
E
A
R
E
A
2'-0
"
2
'
-
0
"
8'-0
"
PRO
P
O
S
E
D
LEA
S
E
A
R
E
A
2
'
-
0
"
EXISTING DUCTING
PROPOSED VERIZON
8'-0"x4'-0"x8'-0" FRP
ENCLOSURE
4'
-
0
"
P
R
O
P
O
S
E
D
L
E
A
S
E
A
R
E
A
2'-0
"
EXISTING OFFICE
ACCESS BELOW.
PROPOSED EQUIPMENT
ROOM. (SEE DET. 3/A-2)
EXISTING
PARKING
EXISTING
PARKING
PROPOSED
LEASE AREA
4'
-
0
"
P
R
O
P
O
S
E
D
L
E
A
S
E
A
R
E
A
EXISTING BUILDING
PARAPET. PROVIDE 2'
CLEARANCE TO NEW
FRP ENCLOSURE
PROPOSED
WALKING
PADS
PROPOSED
HVAC UNITS
MOUNTED
ON EXISTING
ROOFTOP
PROPOSED
VERTICAL
CABLE TRAY
ADJACENT PARCEL
TAX LOT: 1723059026
SUBJECT PARCEL
TAX LOT: 1723059103
SEA CLASSICS
2003 MAPLE VALLEY
HIGHWAY
RENTON, WA 98055
KING COUNTY
DRAWN BY:CHECKED BY:
SHEET TITLE:
SHEET NUMBER:REV.:
DATE
PROJECT INFORMATION:
REVISION DESCRIPTIONREV.
DAP PD
THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY, LLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY, LLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD.
2
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO VERIZON
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO VERIZON IS
STRICTLY PROHIBITED
F R O M Z E R O IOT N F I IN G Y
A-2
90% ZONING DRAWINGS009/8/17
REVISED PRELIM. ZONING DRAWINGS109/12/17
100% ZONING DRAWINGS11/13/172
'0.#4)'&4(
2.#05
1 PROPOSED ANTENNA PLAN 2'1'2'0"
22"x34" SCALE: 1/2" = 1'-0"
11"x17" SCALE: 1/4" = 1'-0"
2 PROPOSED ANTENNA PLAN 2'1'2'0"
22"x34" SCALE: 1/2" = 1'-0"
11"x17" SCALE: 1/4" = 1'-0"
N
N
3 PROPOSED EQUIPMENT PLAN
4 RF INFORMATION
2'1'2'0"
22"x34" SCALE: 1/2" = 1'-0"
11"x17" SCALE: 1/4" = 1'-0"
PROPOSED VERIZON
GPS ANTENNA
PROPOSED VERIZON RRU'S
MOUNTED BEHIND ANTENNAS
(6 PER SECTOR, 12 TOTAL)PROPOSED VERIZON PANEL
ANTENNAS MOUNTED WITHIN FRP
ENCLOSURE (2 PER SECTOR, 4 TOTAL)
PROPOSED VERIZON OVP
(1 PER SECTOR)
PROPOSED VERIZON
8'-0"x4'-0"x8'-0" FRP ENCLOSURE
EXISTING BUILDING
PARAPET
PROPOSED VERIZON WALKING PADS PROPOSED VERIZON
CABLE TRAY
PROPOSED VERIZON 2'
MICROWAVE ANTENNA
PROPOSED VERIZON OVP
(1 PER SECTOR)
PROPOSED VERIZON PANEL
ANTENNAS MOUNTED WITHIN FRP
ENCLOSURE (2 PER SECTOR, 4 TOTAL)
8'-0
"
PRO
P
O
S
E
D
L
E
A
S
E
A
R
E
A
4'
-
0
"
P
R
O
P
O
S
E
D
L
E
A
S
E
A
R
E
A
2'
-
0
"
2'-0
"
8'-0
"
PRO
P
O
S
E
D
L
E
A
S
E
A
R
E
A
4'
-
0
"
P
R
O
P
O
S
E
D
L
E
A
S
E
A
R
E
A
2'
-
0
"
2'-0
"
PROPOSED VERIZON RRU'S
MOUNTED BEHIND ANTENNAS
(6 PER SECTOR, 12 TOTAL)
PROPOSED VERIZON
8'-0"x4'-0"x8'-0" FRP ENCLOSURE
EXISTING BUILDING
PARAPET
PROPOSED VERIZON
WALKING PADS
PROPOSED VERIZON
CABLE TRAY
NOTE:
PROPOSED LEASE AREA ON
),567)/225,664)7
PROPOSED VERIZON
INDOOR HVAC UNIT
PROPOSED 1-HOUR
FIRE RATED WALL
PROPOSED P1000T UNISTRUT
MOUNTED TO WALL
EXISTING 3'-6" WIDE STEEL
DOOR TO BE USED BY
VERIZON, WITH PROPOSED
WITH VERIZON SIGNAGE
PROPOSED VERIZON
GEN PLUG MOUNTED
TO EXTERIOR WALL
PROPOSED
VERIZON
POWER RACK
PROPOSED
VERIZON
BATTERY RACK
FUTURE
VERIZON
EQUIPMENT
RACK
200A PPC
EXISTING BUILDING
EXTERIOR WALLS
10
'
-
0
"
VE
R
I
Z
O
N
L
E
A
S
E
A
R
E
A
14'-8"
VERIZON LEASE AREA
PROPOSED VERIZON
ENTRY PORTS3'-6"
6"6"
2'
-
0
"
3'-6"
EXISTING BUILDING
INTERIOR WALL
PROPOSED VERIZON
CABLE LADDER
PROPOSED VERIZON CONDUIT
ROUTED UP INTERIOR FACE
OF OUTDOOR STAIRWELL
WALL TO ROOF
PROPOSED VERIZON OVP
(2 AT EQUIPMENT ROOM)
UP
UP
UP
SEA CLASSICS
2003 MAPLE VALLEY
HIGHWAY
RENTON, WA 98055
KING COUNTY
DRAWN BY:CHECKED BY:
SHEET TITLE:
SHEET NUMBER:REV.:
DATE
PROJECT INFORMATION:
REVISION DESCRIPTIONREV.
DAP PD
THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, ARE THE PROPERTY OF INFINIGY, LLC AND ARE NOT TO BE USED, IN WHOLE OR IN PART, FOR OTHER PROJECTS WITHOUT THE WRITTEN AUTHORIZATION OF INFINIGY, LLC. IT IS UNLAWFUL FOR ANY PERSON TO AMEND ANY ASPECT OF THESE DRAWINGS WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD.
2
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO VERIZON
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO VERIZON IS
STRICTLY PROHIBITED
F R O M Z E R O IOT N F I IN G Y
A-3
90% ZONING DRAWINGS009/8/17
REVISED PRELIM. ZONING DRAWINGS109/12/17
100% ZONING DRAWINGS11/13/172
0146*
'.'8#6+105
0"
22"x34" SCALE: 1/8" = 1'-0"
11"x17" SCALE: 1/16" = 1'-0"8'6'4'8'2'1 PROPOSED NORTHEAST ELEVATION
3 PROPOSED NORTH WEST ELEVATION 0"
22"x34" SCALE: 1/8" = 1'-0"
11"x17" SCALE: 1/16" = 1'-0"8'6'4'8'2'
NOTE:
PROPOSED EQUIPMENT ENCLOSURE
AND ANTENNA ENCLOSURE TO BE
TEXTURED AND PAINTED TO MATCH
EXISTING BUILDING.
2 PROPOSED SOUTH EAST ELEVATION0"
22"x34" SCALE: 1/8" = 1'-0"
11"x17" SCALE: 1/16" = 1'-0"8'6'4'8'2'
GRADE AT SOUTH CORNER
ELEV. 0'-5" BGL (56.2' AMSL)
(/(9
$*/
RAD CENTER OF PROPOSED VERIZON ANTENNAS
(/(9
$*/
TOP OF PROPOSED VERIZON ANTENNAS & FRP ENCLOSURE
(/(9
$*/
EXISTING ROOF DECK
AVERAGE GRADE
ELEV. 0'-0" AGL (56.6' AMSL)
(/(9
$*/
TOP OF EXISTING PARAPET
(/(9
$*/
TOP OF EXISTING PARAPET
GRADE AT EAST CORNER
ELEV. 0'-6" AGL (57.1' AMSL)
PROPOSED VERIZON
GPS ANTENNA
PROPOSED VERIZON RRU'S
MOUNTED BEHIND ANTENNAS
(3 PER SECTOR, 6 TOTAL)
PROPOSED VERIZON OVP
(1 PER SECTOR)
PROPOSED VERIZON
8'-0"x4'-0"x8'-0" FRP ENCLOSURE
EXISTING BUILDING
PROPOSED VERIZON PANEL
ANTENNAS (2 PER SECTOR, 8 TOTAL)
8'
-
0
"
GRADE AT WEST CORNER
ELEV. 0'-8" BGL (55.9' AMSL)
(/(9
$*/
RAD CENTER OF PROPOSED VERIZON ANTENNAS
(/(9
$*/
TOP OF PROPOSED VERIZON ANTENNAS & FRP ENCLOSURE
(/(9
$*/
EXISTING ROOF DECK
AVERAGE GRADE
ELEV. 0'-0" AGL (56.6' AMSL)
(/(9
$*/
TOP OF EXISTING PARAPET
GRADE AT NORTH CORNER
ELEV. 0'-6" AGL (57.1' AMSL)
(/(9
$*/
TOP OF EXISTING PARAPET
PROPOSED VERIZON
8'-0"x4'-0"x8'-0" FRP ENCLOSURE
EXISTING BUILDING
PROPOSED VERIZON PANEL
ANTENNAS (2 PER SECTOR, 8 TOTAL)
PROPOSED VERIZON
MICROWAVE ANTENNA
PROPOSED VERIZON RRU'S
MOUNTED BEHIND ANTENNAS
(3 PER SECTOR, 6 TOTAL)
PROPOSED VERIZON OVP
(1 PER SECTOR)
EXISTING BUILDING
PROPOSED VERIZON
8'-0"x4'-0"x8'-0" FRP ENCLOSURE
PROPOSED VERIZON
MICROWAVE ANTENNA
8'
-
0
"
EXISTING DOOR AT PROPOSED
VERIZON EQUIPMENT ROOM
PROPOSED VERIZON RRU'S
MOUNTED BEHIND ANTENNAS
(3 PER SECTOR, 6 TOTAL)
PROPOSED VERIZON OVP
(1 PER SECTOR)
PROPOSED VERIZON
GPS ANTENNA
GRADE AT EAST CORNER
ELEV. 0'-6" AGL (57.1' AMSL)
(/(9
$*/
RAD CENTER OF PROPOSED VERIZON ANTENNAS
(/(9
$*/
TOP OF PROPOSED VERIZON ANTENNAS & FRP ENCLOSURE
(/(9
$*/
TOP OF EXISTING PARAPET
(/(9
$*/
EXISTING ROOF DECK
AVERAGE GRADE
ELEV. 0'-0" AGL (56.6' AMSL)
GRADE AT NORTH CORNER
ELEV. 0'-6" AGL (57.1' AMSL)
PROPOSED VERIZON
8'-0"x4'-0"x8'-0" FRP ENCLOSURE
PROPOSED VERIZON PANEL
ANTENNAS (2 PER SECTOR, 8 TOTAL)
EXISTING HVAC