HomeMy WebLinkAboutP_P07_Preliminary_Infiltration_Details_180111_v1ACCEPTABLE FILL MATERIALS: STORMTECH MC-3500 CHAMBER SYSTEMS MATERIAL LOCATION DESCRIPTION AASHTO MATERIAL CLASSIFICATIONS COMPACTION / DENSITY REQUIREMENT D FINAL FILL:FILL MATERIAL FOR LAYER 'D' STARTS FROM THE TOP OF THE 'C' LAYER TO THE BOTTOM OF FLEXIBLE PAVEMENT OR UNPAVED FINISHED GRADE ABOVE. NOTE THAT PAVEMENT SUBBASE MAY BE PART OF THE 'D' LAYER ANY SOIL/ROCK MATERIALS, NATIVE SOILS, OR PER ENGINEER'S PLANS. CHECK PLANS FOR PAVEMENT SUBGRADE REQUIREMENTS. N/A PREPARE PER SITE DESIGN ENGINEER'S PLANS. PAVED INSTALLATIONS MAY HAVE STRINGENT MATERIAL AND PREPARATION REQUIREMENTS. C INITIAL FILL:FILL MATERIAL FOR LAYER 'C' STARTS FROM THE TOP OF THE EMBEDMENT STONE ('B' LAYER) TO 24" (600 mm) ABOVE THE TOP OF THE CHAMBER. NOTE THAT PAVEMENT SUBBASE MAY BE A PART OF THE 'C' LAYER. GRANULAR WELL-GRADED SOIL/AGGREGATE MIXTURES, <35% FINES OR PROCESSED AGGREGATE. MOST PAVEMENT SUBBASE MATERIALS CAN BE USED IN LIEU OF THIS LAYER. AASHTO M145¹ A-1, A-2-4, A-3 OR AASHTO M43¹ 3, 357, 4, 467, 5, 56, 57, 6, 67, 68, 7, 78, 8, 89, 9, 10 BEGIN COMPACTIONS AFTER 24" (600 mm) OF MATERIAL OVER THE CHAMBERS IS REACHED. COMPACT ADDITIONAL LAYERS IN 12" (300 mm) MAX LIFTS TO A MIN. 95% PROCTOR DENSITY FOR WELL GRADED MATERIAL AND 95% RELATIVE DENSITY FOR PROCESSED AGGREGATE MATERIALS. B EMBEDMENT STONE:FILL SURROUNDING THE CHAMBERS FROM THE FOUNDATION STONE ('A' LAYER) TO THE 'C' LAYER ABOVE. CLEAN, CRUSHED, ANGULAR STONE AASHTO M43¹ 3, 4 A FOUNDATION STONE:FILL BELOW CHAMBERS FROM THE SUBGRADE UP TO THE FOOT (BOTTOM) OF THE CHAMBER. CLEAN, CRUSHED, ANGULAR STONE AASHTO M43¹ 3, 4 PLATE COMPACT OR ROLL TO ACHIEVE A FLAT SURFACE. ² ³ 45" (1140 mm) 24" (600 mm) MIN* 8' (2.4 m) MAX 12" (300 mm) TYP77" (1950 mm) ADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE ALL AROUND CLEAN, CRUSHED, ANGULAR STONE IN A & B LAYERS SUBGRADE SOILS (SEE NOTE 4) PAVEMENT LAYER (DESIGNED BY SITE DESIGN ENGINEER) MC-3500 END CAP 12" (300 mm) MIN 9" (230 mm) MIN DEPTH OF STONE TO BE DETERMINED BY SITE DESIGN ENGINEER 9" (230 mm) MIN D C B A *TO BOTTOM OF FLEXIBLE PAVEMENT. FOR UNPAVED INSTALLATIONS WHERE RUTTING FROM VEHICLES MAY OCCUR, INCREASE COVER TO 30" (750 mm). PERIMETER STONE (SEE NOTE 6) EXCAVATION WALL (CAN BE SLOPED OR VERTICAL) 6" (150 mm) MIN *FOR COVER DEPTHS GREATER THAN 8.0' (2.4 m) PLEASE CONTACT STORMTECH PART #STUB B C MC3500IEPP06T 6" (150 mm) 33.21" (844 mm)--- MC3500IEPP06B ---0.66" (17 mm) MC3500IEPP08T 8" (200 mm) 31.16" (791 mm)--- MC3500IEPP08B ---0.81" (21 mm) MC3500IEPP10T 10" (250 mm) 29.04" (738 mm)--- MC3500IEPP10B ---0.93" (24 mm) MC3500IEPP12T 12" (300 mm) 26.36" (670 mm)--- MC3500IEPP12B ---1.35" (34 mm) MC3500IEPP15T 15" (375 mm) 23.39" (594 mm)--- MC3500IEPP15B ---1.50" (38 mm) MC3500IEPP18TC 18" (450 mm) 20.03" (509 mm)--- MC3500IEPP18BC ---1.77" (45 mm) MC3500IEPP24TC 24" (600 mm) 14.48" (368 mm)--- MC3500IEPP24BC ---2.06" (52 mm) MC3500IEPP30BC 30" (750 mm)--- NOMINAL CHAMBER SPECIFICATIONS SIZE (W X H X INSTALLED LENGTH)77.0" X 45.0" X 86.0" (1956 mm X 1143 mm X 2184 mm) CHAMBER STORAGE 109.9 CUBIC FEET (3.11 m³) MINIMUM INSTALLED STORAGE*178.9 CUBIC FEET (5.06 m³) WEIGHT 135.0 lbs.(61.2 kg) NOMINAL END CAP SPECIFICATIONS SIZE (W X H X INSTALLED LENGTH)77.0" X 45.0" X 22.5" (1956 mm X 1143 mm X 571 mm) END CAP STORAGE 14.9 CUBIC FEET (0.42 m³) MINIMUM INSTALLED STORAGE*46.0 CUBIC FEET (1.30 m³) WEIGHT 50.0 lbs.(22.7 kg) *ASSUMES 12" (305 mm) STONE ABOVE, 9" (229 mm) STONE FOUNDATION AND BETWEEN CHAMBERS, 12" (305 mm) STONE PERIMETER IN FRONT OF END CAPS AND 40% STONE POROSITY MC-3500 TECHNICAL SPECIFICATION NTS 90.0" (2286 mm) ACTUAL LENGTH 86.0" (2184 mm) INSTALLED BUILD ROW IN THIS DIRECTION NOTE: ALL DIMENSIONS ARE NOMINAL CUSTOM PRECORED INVERTS ARE AVAILABLE UPON REQUEST. INVENTORIED MANIFOLDS INCLUDE 12-24" (300-600 mm) SIZE ON SIZE AND 15-48" (375-1200 mm) ECCENTRIC MANIFOLDS. CUSTOM INVERT LOCATIONS ON THE MC-3500 END CAP CUT IN THE FIELD ARE NOT RECOMMENDED FOR PIPE SIZES GREATER THAN 10" (250 mm) THE INVERT LOCATION IN COLUMN 'B' ARE THE HIGHTEST POSSIBLE FOR THE PIPE SIZE. LOWER JOINT CORRUGATION WEB CREST CREST STIFFENING RIB VALLEY STIFFENING RIB B C 77.0" (1956 mm) 45.0" (1143 mm) 25.7" (653 mm) FOOT 77.0" (1956 mm) 45.0" (1143 mm) STUBS AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH "B" STUBS AT TOP OF END CAP FOR PART NUMBERS ENDING WITH "T" UPPER JOINT CORRUGATION 22.5" (571 mm) INSTALLED NOTES: 1.INSPECTION PORTS MAY BE CONNECTED THROUGH ANY OF (6) CHAMBER CORRUGATION VALLEYS 2.ALL PVC FITTINGS ARE TO BE SOLVENT CEMENTED CONNECTION DETAIL 8" [203 mm] 4" [100 mm] SCHED 40 PVC COUPLING 4" [100 mm] SCHED 40 PVC 4" [100 mm] SCHED 40 PVC CORE 4.5" [114 mm] Ø HOLE IN CHAMBER (4.5" HOLE SAW REQ'D) ANY OF (6) VALLEY LOCATIONS MC-3500 CHAMBER 4" [100 mm] SCHED 40 SCREW-IN CAP AASHTO M288 CLASS 2 NON-WOVEN GEOTEXTILE 3/4 - 2 INCH [19 mm - 51 mm] CLEAN CRUSHED ANGULAR STONE NYLOPLAST 12" [300 mm] INLINE DRAIN BODY W/ 12" [300 mm] SOLID HINGED COVER AND FRAME (SEE NYLOPLAST DWG# 7003-110-044 FOR PAVED APPLICATIONS / SEE DWG# 7003-110-045 FOR UNPAVED APPLICATIONS) CONCRETE COLLAR PAVEMENT GRANULAR WELL GRADED SOIL / AGGREGATE MIXTURES 6.5' [1.98 m] MAX. 24" [610 mm] MIN. SUMP DEPTH TBD BY DESIGN ENGINEER CATCH BASIN OR MANHOLE MC-3500 ENDCAP COVER ENTIRE ROW WITH AASHTO M288 CLASS 2 NON-WOVEN GEOTEXTILE. MC-3500 - 12.5' [3.81 m] WIDE STRIP INSPECTION PORT DETAILISOLATION ROW DETAIL IN COMPLIANCE WITH CITY OF RENTON STANDARDS ---- GREEN'S LANDING SHORT PLAT G R E E N 'S L A N D I N G S H O R T P L A T S H E E T 0 7 L U A ---- C ---- G R E E N 'S L A N D I N G S H O R T P L A T R----- P R ----