Loading...
HomeMy WebLinkAboutBAKER B2 MODEL NOT FOR CONSTRUCTION 2021TANKLESS HOT WATER HEATER 6' - 0 1 / 2 " A 2 BCC 1 3 4 4' - 8 1 / 2 " 4' - 3 " 8' - 7 " 4 1 / 2 " 6' - 0 1 / 2 " 2'-1"2'-4" 6'-0"12'-0"8'-0" 5' - 0 " 3'-0"3'-0" HEATPUMP CONDENSOR 5'-1 7/8" E D E 4' - 1 0 " 3' - 0 " 4" 3' - 0 " 4' - 1 0 " A A B B 11'-5 3/8" 26'-0" 16 ' 7' - 4 " F 3' - 1 1 1 / 2 " 3' - 8 1 / 2 " HEATPUMP HEAD MODEL B2 THE BAKER B2 . B A K E R WINDOW SCHEDULE SCHEDULES DOOR SCHEDULE 4'-0" X 6'-8"INT DOUBLE BIFOLD KEY HAND SIZE TYPE NOTES 1 3'-O" X 6'-8"EXT. ENTRY 2 3 2' 6" X 6'-8"INT PASSAGE 4 RH LH LH NA 2'-6" X 6'-8"INT PASSAGE KEY QUANT R.O. SIZE TYPE A 1 B 1 C 2 D 1 2'-4" X 3'-4"DOUBLEHUNG E 3'-0" x 4'-4"DOUBLEHUNG NOTESHDR 7'-6" TEMPERED 2'-6" x 3'-4"DOUBLEHUNG 6'-8" 3'-0" x 5'-0"DOUBLEHUNG 6'-8"EGRESS 2 3'-0" X 5'-6"DOUBLEHUNG 7'-6" 6'-8" AREA 7.8 SQ. FT 8.3 SQ. FT 14 SQ. FT. 30 SQ. FT 36 SQ. FT F 1 2'-8" X 2'-4"AWNING SEE ELEV 7.8 SQ. FTTEMPERED TOTAL 103.9 SQ. FT SEE ENERGY NOTES, SHEET 1, FOR REQUIRED U-VALUES. ALL WNDWS TO BE NFC CERTIFIED VERIFY OPENING WITH EXTERIOR ELEVATIONS 5'-11 1/4"2'-6"7'-3 3/4"3'-0"4"3'-0"3'-11 1/4" 6' - 4 " 3' - 4 " 6' - 4 " SHIPS LADDER WITH MIN 20" CLEAR WIDTH, TREAD DEPTH NO LESS THAN 5" AND TEH TREAD PROJECTION, INCLUDING THE NOSING PROJECTION, IS NOT LESS THAN 8 1/2." RISER HEIGHT SHALL NOT BE MORE THAN 9 1/2". HANDRAILS ON BOTH SIDES, BETWEEN 30" AND 34" HIGH. SEE R311.7.12 LADDER NOTE: LADDER UP TO LOFT- SEE NOTE BELOW SMOKE DETECTOR AND CARBON MONOXIDE ALARM - HARDWIRED W/ BATTERY BACKUP- SMOKE DETECTOR TO BE LOCATED IN HIGHEST PART OF CEILING EXHAUST FAN - SEE MECH NOTES PLAN LEGEND INTERIOR LOAD BEARING WALLS - NO CHANGES ALLOWED VENT TO WALL VENT TO ROOF THROGUH STORAGE APPROVED ALTERNATE _____________________________________________________________________________ AREA CALCS NEW ADU :418 SQ. FT. TOTAL BUILDING AREA:478 SQ. FT. NEW PORCH 60 SQ. FT. NEW WALKWAY:___SQ. FT. BUILDING OVERHANG:532 SQ. FT. TOTAL IMPERVIOUS SURFACE:___ SQ. FT. TOTAL IMPERVIOUS SURFACE SHEET INDEX HEIGHT ROOF PITCH:3:12 RIDGE HEIGHT:16'-7" BUILDING AREA MIN. EXISTING HOUSE REQUIRED (TO MEET 75% MAXIMUM)557 SQ. FT. SHEET 2 SHEET 3 SHEET 1 BUILDING SECTIONS, EXTERIOR ELEVATIONS, EXTERIOR FINISH NOTES ENERGY NOTES, ENERGY CREDITS, MECHANICAL NOTES, BUILDING ENVELOPE NOTES FLOOR PLANS, AREA CALCS, SCHEDULES, GENERAL NOTES SHEET 4 DETAILS SKYLIGHTS BETWEEN TRUSSES OR RAFTERS: OPENINGS CANNOT BE LARGER THAN REQUIRED TO FIT BETWEEN STRUCTRAL COMPONENTS AS REQUIRED IN FRAMING PLANS, WITHOUT ALTERATION. LOWER SIDING HORIZONTAL LAP SIDING W 5" EXPOSURE SHINGLES (WEAVE CORNERS) CONSTRUCTION OPTIONS FINISHES ROOFING 10 SQ. POST PER DETAIL ____ PORCH ROOF CONSTRUCTION PAINT COLORS: ENTRY DOOR:PROVIDE DOOR SPEC SHEET APPROVED ALTERNATE _____________________________________________________________________________ COMPOSITION ROOFING, COLOR TO BE _______________________________________________________________ METAL ROOFING, COLOR TO BE ______________________________________________________________________ GRADE AT BUILIDING SITE FLAT SITE (LESS 2% ACROSS BUILDING ) SLOPE EXCEEDS 2% - USE STEP FOOTING DETAIL PER STRUCTURAL - CONCRETE STEM WALL TO EXTEND TO BOTTOM OF FLOOR LEVEL PER TYP DETAILS NO PONY WALLS ALLOWED BELOW FLOOR FRAMING NO GRADE CHANGE FROM PLANS ALLOWED AT PORCH LOCATIONS - MAINTAIN 3 STEPS FROM GRADE TO DECK 10 SQ. POST, WITH BRICK OR CULTURED STONE PIER PROVIDE COLOR INFORMATION (MANUFACTURER & COLOR NUMBER) 3' WIDE ACCESS PANEL 1 OF 4 SKYLIGHTS - CAN BE ADDED IF LOCATED BETWEEN TRUSSES. NO CHANGES TO ROOF FRAMING ALLOWED TO ACCOMODATE SKYLIGHTS - U-VALUE AS INDICATED IN ENERGY NOTES. SKYLIGHTS TO HAVE A 4" CURB. VERIFY SWING WITH PLANS , SWING INDICATED BELOW IS REFERENCED IN DIRECTION OF TRAVEL SEE ENERGY NOTES, SHEET 3, FOR REQUIRED U-VALUES FOR GLAZED DOOR, EXCEPT ENTRY DOOR GLAZING IN ALL FIXED AND OPERABLE PANELS OF SWINGING, SLIDING AND BIFOLD DOORS SHALL BE CONSIDERED A HAZARDOUS LOCATION. PER R308.4.1 SAFETY GLAZING IS REQUIRED SAFETY GLAZING (TEMPERING) IN HAZARDOUS LOCATIONS: AS REQUIRED PER IRC R308. 1. IN BATHROOMS AND SHOWERS AND OTHER WET LOCATIONS W/ GLAZING LESS THAN 60" ABOVE THE FLOOR LEVEL 2. ADJACENT TO A DOOR WHERE NEAREST VERTICAL EDGE IS WITHIN A 24" ARC OF EITHER VERITCAL DOOR EDGE WHEN IN THE CLOSED POSITION. UNLESS THE GLAZING IS MORE THAN 60" ABOVE FLOOR LEVEL OR IF THERE IS A INTERVENING WALL OR PARTITION BETWEEN GLAZING & DOOR 3. GLAZING IN ANY FIXED OR OPERABLE PANEL WHEN ALL OF THE FOLLOWING APPLY: EXPOSED AREA IS GREATER THAN 9 SQ. FT. BOTTOM EDGE IS LESS THAN 18" ABOVE FLOOR TOP EDGE IS GREATER THAN 36" ABOVE FLOOR ONE OR MORE WALKING SURFACES ARE WITHIN 36" HORIZONTALLY OF GLAZING 4. GLAZING NEXT TO STAIRS AND RAMPS: WHERE THE GLAZING IS LESS THAN 36" ABOVE THE PLANE OF ADJACENT WALKING SURFACE OF STAIRWAYS, LANDING BETWEEN FLIGHTS OF STAIRS AND RAMPS. 5' - 0 " SINKDW STOVE W/D3'X3' SHOWER LOFT ABOVE SCALE 1/4"= 1'-0" B2. FLOOR PLAN "GREAT ROOM" BEDROOM LADDER DOWN SCALE 1/4" = 1'-0" B2. LOFT PLAN "GREAT ROOM"PLAY LOFT STORAGE 36" HIGH WAL OR RAILING OPEN TO BELOW ROOF BELOW 30" REF 36" HIGH WAL OR RAILING 26'-0" 16 ' ENTRY PORCH GENERAL NOTES INTERNATIONAL RESIDENTIAL CODE, WITH THE ASSOCIATED MECHANICAL AND PLUMBING SECTIONS, 2018 EDITION, THE 2018 INTERNATIONAL FIRE CODE AND THE 2018 WSEC AND ALL APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION TO BE FOLLOWED. ALL BUILDING SITES TO BE LEVEL, MAXIMUM 2% SLOPE, OR TO BE MADE LEVEL BY MEANS OF RETAINING STRUCTURE INDEPENDENT OF THE BUILDING STRUCTURE. LANDSCAPE RETAINING WALLS TO BE MAX 4' HIGH, UNSUPPORTED. IF RETAINING WALLS MORE THAN 4' TALL ARE NEEDED THEY WOULD NEED TO BE ENGINEERED SEPARATELY. FINAL GRADE AT PORCHES AND OTHER EXTERIOR DOORS TO BE AS SHOWN ON PLANS, WITH MAX THREE STEPS DOWN. ALL DOORS NOT DIMENSIONED SHALL BE LOCATED MIN 3 1/2" FROM PERPENDICULAR STUD WALL INTERIOR DIMENSIONS ARE TO OUTSIDE OF GYP BD SURFACE. EXTERIOR DIMENSIONS ARE TO STUDS. APPROVED PLANS SHOULD BE ON-SITE AT ALL TIME AND CANNOT BE ALTERED WITHOUT THE AUTHORIZATION OF THE BUILDING OFFICIAL. CONTRACTOR TO COORDINATE WITH OWNER FOR LOCATION ON SITE OF TEMPORARY POWER, SANITARY CAN, AND OTHER CONSTRUCTION RELATED EQUIPMENT. STORAGE OF MATERIALS, GARBAGE DISPOSAL AND WORK HOURS TO BE DISCUSSED WITH OWNER. PROVIDE ALL COMPLIANCE INFORMATION FOR INSULATION INSTALLED, MECHANICAL SYSTEM PRODUCT LITERATURE, AND WINDOWS AND DOOR COMPLIANCE INFORMATION, AND ANY OTHER INFORMATION REQUIRED BY WSEC OR IRC THAT NEEDS DOCUMENTATION. EXTERIOR WALLS TO BE 2X6 STUDS @ 16" O.C. UNLESS NOTED OTHERWISE, INTERIOR WALLS TO BE 2X4 STUDS @ 16" O.C. UNLESS NOTED OTHERWISE PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL PERMANENT CONNECTIONS HAVE BEEN INSTALLED. CONTRACTOR SHALL VERIFY ALL ROUGH-IN DIMENSIONS AND REQUIREMENTS FOR EQUIPMENT SELECTED BY OWNERS. DIMENSION FOR WIINDOWS ARE ROUGH-OPENINGS, DIMENSIONS FOR DOORS ARE FOR NOMINAL DOOR SIZE, NOT ROUGH-OPENING. ALL ROUGH OPENINGS TO BE VERIFIED WITH OWNER FOR ACTUAL MANUFACTURERS REQUIREMENTS. DO NOT SCALE DRAWINGS. ALL DIMENSIONS TO BE FIELD VERIFIED. PROVIDE PERFORATED DRAINAGE FOOTING PIPES PER FOUNDATION PLAN - TIGHTLINE TO DAYLIGHT, DIRECT AWAY FROM ADJACENT STRUCTURES, EITHER ON SUBJECT LOT, OR ADJACENT LOTS. DOWNSPOUTS TO HAVE SPLASH BLOCKS- ROUTE DRAINAGE AWAY FROM THE BUILDING FOUNDATION AS WELL AS ANY ADJACENT STRUCTURES. ALL FOOTINGS TO BEAR ON FIRM, UNDISTURBED EARTH BELOW ORGANIC SURFACE SOILS. FOOTINGS NOT TO BE PLACED ON FILL. PROVIDE FREE-DRAINING FILL AND SLOPE GRADE 1% AWAY FROM BUILDING FOUNDATION. BACKFILL TO BE FIRMLY COMPACTED. NO CHANGES TO DRAWINGS TO BE MADE THAT IMPACT THE STRUCTURAL SYSTEMS INCLUDING: NO CHANGES TO EXTERIOR WALLS DIMENSIONS, INCLUDING OPENING SIZES AND LOCATION NO CHANGES TO FLOOR OR ROOF FRAMING EXCEPT AS ALLOWED IN STRUCTURAL NOTES. NO CHANGES ALLOWED IN INTERIOR BEARING WALLS, IF INDICATED ON PLANS. CHANGES TO DRAWINGS ALLOWED OUTRIGHT: INTERIOR FINISHES, CABINETRY LAYOUT, PLUMBING AND ELECTRICAL LAYOUTS AS LONG AS ALL CHANGES COMPLY WITH APPLICABLE CODES. FINISH FLOOR TO BE MAX 3/4" THICK . GRADE AT CARRIAGE HOUSE UNITS CAN VARY. THE DIFFERENCE BETWEEN GRADE AT THE VEHICULAR DOOR OPENING AND THE OPPOSITE SIDE OF THE STRUCTURE SHALL NOT CREATE A RETAINING WALL WITH MORE THAN 4 FEET OF UNSUPPORTED FILL. DATE: DRN: REV: 8/15/21 ji l l s o u s a a r c h it e c t 28 1 5 N . L a w r e n c e T a c o m a , W A 9 8 4 0 7 tel e : 2 5 3 . 4 6 8 . 9 6 6 2 ji l l @ j i l l s o u s a a r c h t e c t . c o m JFS RE N T O N A D U s REGISTERED ARCHITECT Jill Fuerstneau Sousa STATE OF WASHINGTON NOT VALID UNLESS SIGNED 7155 PERMIT SET REVIEWED BUILDING DIVISION By: Rick Lee Date: 06/08/2022 THIS SET OF REVIEWED PLANS INCLUDE BOTH THE SUBMITTED DESIGN AND ADDITIONAL CODE REQUIREMENTS MARKED IN RED. PLANS MUST BE MADE AVAILALE ON THE JOB AT ALL TIMES DURING CONSTRUCTION. THIS BUILDING / PROJECT IS NOT TO BE OCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTON BUILDING DIVISION INSPECTOR: SEE SHEET 3 FOR REQUIRED ENERGY CREDITS FOR 2021 WASHINGTON STATE ENERGY CODE - RESIDENTIAL