Loading...
HomeMy WebLinkAboutReport 1REPORT City of Renton & Department of Planning / Building / Public Works DECISION ADMINISTRATIVE SHORT PLAT REPORT & DECISION A. SUMMARY AND PURPOSE OF REQUEST: REPORT DATE: October 17.2007 Project Name: Teets Short Plat . Applicant/ Contact: Afplicant: Darcey Teets Contact: Joe Hopper, P.E. 2 38 109'h Avenue SE Pacific E',lIlineering Design, LLC Bellevue, W A 98004 15445 53 Avenue, S. SUite 100 Seattle, W A 98188 File Number: LUA 07-101, SHPL-A Project Manager: Andrea Petzel, Planner Project Description: Application for administrative short plat approval for a 2-lot subdivision in the R-8 zone. Density would be 7.4 dwelling units/acre. The existing home would be demolished. Proposed lot sizes would be 5,880 SF. and 5,733 SF. Both new lots would have direct access to Meadow Avenue North via private driveways. The applicant would be required to dedicate 5 feet of width along the street frontage for improvements. There are two significant trees onsite, and no critical areas are present. Project Location: 3612 Meadow Avenue North Project Location Map City of Renton P/B/PW Department Administrative Land Use Action TEETS SHORT PLAT, PROJECT LUA 07-101, SHPL-A REPORT AND DECISION Dated October 17, 2007 B. GENERAL INFORMATION: 1. Owners of Record: 2. Zoning Designation: Denney and Robin Teets 3 S. Hollow Road Dix Hills, NY 11746 Residential-8 dulac (R-8) Doris I. Pease 16205 SE 9"' Street Bellevue, W A 98008 3. Comprehensive Plan Designation: Residential Single Family (RSF) 4. Existing Site Use: Existing single family residence to remain 5. Neighborhood Characteristics: 6. 7. North: Single Family Residential (R-8 zone) East: Interstate Highway 405 South: Single Family Residential (R-8 zone) West: Single Family Residential (R-8 zone) Access: Driveway access off of Meadow Avenue North Site Area: 12,151 SF (0.28 acres) C. HISTORICAVBACKGROUND: Annexation Comprehensive Plan Zoning D. PUBLIC SERVICES: 1. Utilities: Land Use File No. N/A N/A N/A Ordinance No. 1804 5099 5\00 Water: There is an existing l2-inch watennain in Meadow Avenue N. Sewer: There is an existing 8-inch sanitary sewer main in Meadow Avenue N. Surface Water/Stann Water: There are no stann facilities at this site. 2. Streets: There is no sidewalk, curb, or gutter fronting the project site. 3. Fire Protection: City of Renton Fire Department E. APPLICABLE SECTIONS OF THE RENTON MUNICIPAL CODE: 1. Chapter 2 Land Use Districts Section 4-2-020: Purpose and Intent of Zoning Districts Section 4-2-070: Zoning Use Table Section 4-2-110: Residential Development Standards 2. Chapter 4 Property Development Standards Section 4-4-030: Development Guidelines and Regulations 3. Chapter 6 Streets and Utility Standards Section 4-6-060: Street Standards 4. Chapter 7 Subdivision Regulations Section 4-7-070: Detailed Procedures for Short Subdivisions Page 2 Date 12/8/59 1111104 1111104 Section 4-7-120: Compatibility with Existing Land Use and Plan·General Requirements and Minimum Standards City of Renton P!BIPW Department Administrative Land Use Action TEETS SHORT PLAT, PROJECT LUA 07-101, SHPL-A REPORT AND DECISION Dated October 17, 2007 Section 4-7 -150: Streets-General Requirements and Minimum Standards Section 4-7-170: Residential Lots-General Requirements and Minimum Standards 4. Chapter 9 Procedures and Review Criteria F. APPLICABLE SECTIONS OF THE COMPREHENSIVE PLAN: I. Land Use Element -Residential Single Family 2. Community Design Element G. DEPARTMENT ANALYSIS: 1. Project Description/Background Page3 The applicant is proposing to subdivide a O.2S-acre (12,151 SF) parcel zoned Residential-S (R-S) dwelling units per acre into two lots. The property is located east side of Meadow Avenue North, just north of North 36th Street. The existing single-family residence will be removed. Proposed net lot sizes are as follows: Lot 1: 5,S80 SF Lot 2: 5,733 SF There are no street improvements and an approximate 539 SF dedication wonld be required for installation of half-street improvements. Subtracting that from the gross area of the plat, the proposal for two new lots would amve at a density of7.4 dwelling units per net acre (du/ac). There are no critical areas onsite. Access to both proposed lots would be via separate private driveways from Meadow Avenue North. The site is vegetated with grass and shrubs, as well as two significant trees. 2. Environmental Review Except when located on lands covered by water or sensitive areas, short plats are exempt from SEPA Environmental Review pursuant to WAC 197-11-800(6)(a). 3. Compliance with ERC Conditions N!A 4. Staff Review Comments Representatives from various city departments have reviewed the application materials to identify and address issues raised by the proposed development. These comments are contained in the official file, and the essence of the comments has been incorporated into the appropriate sections of this report and the Departmental Recommendation at the end of the report. 5. Consistency Short Plat Criteria Approval of a plat is based upon several factors. The following short plat criteria have been established to assist decision-makers in the review of the plat: a) Compliance with the Comprehensive Plan Designation The sIte is designated Residential Single Family (RSF) on the Comprehensive Plan Land Use Map. Lands in the RSF designation are intended for use as quality residential detached development organized into neighborhoods at urban densities. It is intended that larger subdivision, infill development, and rehabilitation of existing housing be carefully designed to enhance and improve the quality of single-family living environments. The proposal is City of Renton PIBIPW Department Administrative Land Use Action TEETS SHORT PLAT, PROJECT LUA 07-101, SHPL·A REPORT AND DECISION Dated October 17, 2007 Page 4 b) consistent with the following Comprehensive Plan Land Use and Community Design Element policies: Policy LU-147. Net development densities shouldfall within a range of 4.0 to 8.0 dwelling units per acre in Residential Single Family neighborhoods. The proposed project for two lots would arrive at a net density of 7.4 dwelling units per net acre, which is within the density range permitted. Policy LU-148. A minimum lot size of5,OOO SF should be allowed on in-fill parcels of less than one acre (43,560 sq. ft.) in single-family designations. Allow a reduction on lot size to 4,500 SF on parcels greater than one acre to create an incentive for aggregation of land. The minimum lot size is not intended to set the standard for density in the designation, but to provide flexibility in subdivision/plat design and facilitate development within the allowed density range. Both proposed lots exceed the minimum lot size of 5,000 SF. Policy LU-152. Single-family lot size, lot width, setbacks. and impervious surface should be sufficient to allow private open space, landscaping to provide buffers/privacy without extensive fencing. and sufficient area for maintenance activities. The proposed new lots would meet the required lot size, width, and setbacks to create sufficient front, rear, and side yard areas. Policy LU-154. Interpret development standards to support new plats and injill project designs incorporating street locations. lot configurations. and building envelopes that address privacy and quality of life for existing residents. The proposed lots are would be oriented such that all ofthe lots would have direct access to a public right-of-way. The two proposed lots would be oriented to face Meadow Avenue North, thus matching the houses on the abutting lots. Approval of this application would not decrease the quality of life for residents in the immediate vicinity. Policy CD-12. Infill development. defined as new short plats of nine or fewer lots, should be encouraged in order to add variety, updated housing stock. and new vitality to neighborhoods. The proposed short plat would subdivide an existing parcel into two lots. A new residence could be constructed on proposed Lot 2, updating the housing stock in the existing neighborhood. Compliance with the Underlying Zoning Designation The subject site is designated R-8 on the City of Renton Zoning Map. The proposed development would allow for the future construction of one new single-family dwelling unit. The allowed density range in the R-8 zone is a minimum of 4.0 to a maximum of 8.0 dwelling units per acre. After subtracting approximately 539 SF for right-of-way dedication, the net lot area is 0.27 acres. The proposal for two lots on 0.27 acres arrives at a density of 7.4 dwelling units per acre, which falls within the permitted density range for the R-8 zone. The allowed building lot coverage for lots over 5,000 SF in size in the R-8 zone is 35 percent or 2,500 SF, whichever is greater. The existing house on Lot I does not comply with setback requirements and will be removed. Staff recommends as a condition of short plat that the applicant obtain a demolition permit and all required inspections completed for the removal of the existing house and garage prior to the recording of the final plat. Both lots comply with the lot size requirements. City of Renton PIB/PW Department Administrative Land Vse Action TEETS SHORT PLAT, PROJECT LUA ()7-10I, SHPL-A REPORT AND DEC/SIOlV Dated October 17, 2007 PageS c) d) The required setbacks in the R-8 zone are as follows: front yard is 15 feet for the primary structure and 20 feet for an attached garage; interior side yard is 5 feet; side yard along a street is 15 feet for the primary structure and 20 feet for an attached garage; and the rear yard is 20 feet. Both lots provide adequate room for structures that would comply with setback requirements. The parking regulations require that detached or semi-attached dwellings provide a minimum of 2 off-street parking spaces. As proposed, each lot would have adequate area to provide two ofl~street parking spaces. Compliance with the parking requirements will be verified at the time of building permit review. Community Assets The site is vegetated primarily with shrubs, groundeover and a total of two significant trees. The regulations regarding tree protection/retention require that trees on developable lots be mamtained to the maximum extent feasible, and they permit the City to require the replacement of trees that would implement the intent of the regulations. The Development Services Director has made a determination that to comply with these requirements, 25 percent of all protected trees shall be retained or replaced. Of the two existing trees, one, the 33-inch hemlock in the southwest corner of proposed Lot I is proposed to remain. This results in a retention rate of 50 percent and complies with the Director's determination and City regulations. In order to preserve and protect the tree during utility and building construction, staff recommends as condition of approval that the tree be fenced off around the drip line and a sign posted that the tree is to be preserved. The City's landscaping regulations require the installation of landscaping within the public right-of-way. The minimum amount of landscaping required for sites abutting a non-arterial public street is 5 feet, provided that if there is addItional undeveloped right-of-way in excess of 5 feet, this shall also be landscaped. A determination has been made that if no additional arca is available within the public right-ol~way due to required improvements, the 5-foot landscaped strip may be located within private property abutting the public right-of-way. Thc landscaping proposed shall either consist of drought resistant vegetation or shall be irrigated appropriately. In addition, the applicant will be required to plant two ornamental trees, a minimum caliper of 1-1/2 inches (deciduous) or 6 -8 feet in height (conifer), within the IS-foot front yard setback area for the proposed lots. Existing landscaping may be used to augment the required landscaping. A eonceptuallandscape plan was submitted with the application. The plan indicates two street trees on Lot I and only one tree on Lot 2. As a condition of approval staff recommends that a revised, detailed landscape plan with the required street trees. All landscaping shall be installed prior to linal inspection of the buildings. Native or drought tolerant species should be used, or an irrigation plan is required. If applicable, fence details should be included in the landscape plan. Allowable fence height is 48" in the front yard (42" 111 clear vision areas), and 72" in the rear and side yards. Side yards begin fifteen feet back from the front property line. Compliance with Subdivisioll Regulatiolls Streets: No new public streets would be created as part of the proposed short plat. Meadow Avenue North is classified as a Collector Street on the City's Arterial Street Map. There are no existing frontage improvements along the parcel's Meadow Avenue North street frontage. The applicant is required to dedicate five feet in width (approximately 539 City of Renton P/B/PW Department Administrative Land Use Action TEETS SHORT PLAT, PROJECT LUA 07-101, SHPL-A REPORT AND DECISION Dated October J 7, 2007 Page 6 e) SF) for half-street improvements along the parcel's frontage in order to install curb, gutter and sidewalk. The proposed short plat is anticipated to generate additional traffic on the City's street system. In order to mitigate transportation impacts, staff recommends a condition of approval be placed on the project requiring a Transportation Mitigation Fee based on $75.00 per net new average daily trip attributed to the project. One new lot (credit given for the existing residence) is expected to generate approximately 9.57 new average weekday trips. The fee for the proposed short plat is estimated at $717.75 ($75.00 x 9.57 trips x 1 lot ~ $717.75) and is payable prior to the recording of the short plat. All wire utilities shall be installed underground per the City of Renton Under Grounding Ordinance. If three or more poles are required to be moved by the development design, all existing overhead utilities shall be placed underground. Blocks: No new blocks will be created as part of the proposed short plat. Lots: The size, shape, orientation, and arrangement of the proposed lots comply with the requirements of the Subdivision Regulations and the development standards of the R-8 zone and allow for reasonable infill of developable land. Both lots are rectangular in shape and front Meadow Avenue North. As demonstrated in the table below, alllots meet the requirements for minimum lot size depth, and width. Lot Size Depth Width 5,000 SF minimum 50 feet required 65 feet required Lot 1 5,880 SF 107.9 feet 53.8 feet Lot 2 5,733 SF 105.2 feet 53.8 feet Reasonableness of Proposed Boundaries Access: Each lot would have direct access to a public right-oj~way via single-family residential driveways. There is an existing garage access easement on proposed Lot 2 (Rec. # 9312102007) that the applicant proposes to relinquish. Because any new structure would be unable to meet setback requirements on this lot with the easement still in place, staff recommends as a condition of approval that the easement be relinquished prior to recording the short plat. Topography: Both proposed lots are relatively level; however, there is a significant grade change of approximately 13 feet between Lots I and 2, with an existing retaining wall. In order to address the grade change the applicant submitted a geotechnical report from Geotech Consultants, Inc. (dated July 27,2007). Both lots will be graded so that each lot has a somewhat flat grade; the southern lot will be higher than the northern not, which is consistent with existing conditions. The report found no groundwater seepage or unusual soil conditions. In order to protect the integrity of the future homes, staff recommends adhering to the recommendations made in the geotechnical report. Because the applicant has not decided on the amount of grading that will be done to level the site, it should be noted that if more than 500 cubic yards of fill is moved, Environmental Review (SEPA) will be required. City of Renton P/B/PW Department Administrative Land Usc Action TEETS SHORT PLAT, PROJECT LUA 07-101, SHPL-A REPORT AiVD DECIS/O]\, Dated October Ii, 2007 Page 7 j) Relatiollship to Existillg Uses: The properties surrounding the subject site are single-famdy residences and arc designated R-8 on the City's zoning map. The proposal is similar to existing development patterns in the area and is consistent with the Comprehensive Plan and Zoning Code, which encourage residential infill development. Availability alld Impact 011 Public Services (Timeliness) Po/ice alld Fire: Police and Fire Prevention staff indicate that sufficient resources exist to furnish services to tlie proposed development, subject to the condition that the applicant provide Code required improvements and fees. A Fire Mitigation Fee, based on $488.00 per new single-family lot with credit given for the existing single-family residence, is recommended in order to mitigate the proposal's potential impacts to City emergency services. The fee is estimated at $488.00 ($488.00 x 1 new lot = $488.00) and is payable prior to the recording of the short plat. Street addresses shall be visible from a public street. Schools: According to the Draft Environmental Impact Statement for the City of Renton Land Use Element (January 16, 1992), the City of Renton has a student generation factor of 0.44 students per single-family residential dwelling. Based on the student generation factor, the proposed short plat would result in 0.44 additional students (0.44 X 1 lot = 0.44) to the local schools. It is anticipated that the Renton School District can accommodate any additional students generated by this proposal at the following schools: Kennydale Elementary, McKnight Middle School and Hazen High School. Surface Water: The runofffrom the new lot must use infiltration per design by a professional engineer, or be tightlined into the storm drainage system or other options as listed in, and in accordance, with the 1990 King County Surface Water Design Manual. Infiltration is allowed if the soils are acceptable. The Surface Water System Development charges are required, and based on a rate of $759.00 per new single-family lot (estimated total of $759.00 with credit for the existing lot). Payment of this fcc will be required prior to issuance of utility construction permit. A temporary erosion control plan will be required and shall be installed and maintained to the satisfaction of the representative of the Development Services Division for the duration of the project. This includes installing a silt fence along the perimeter of the site that is to be disturbed. The silt fence shall be in place before clearing and grading is initiated. This will be required during the construction of both off-site and on-site improvements as well as building construction. Due to the potential for erosion to occur during project construction, staff recommends as a condition of approval that the project be required to comply with the Department of Ecology's Erosion and Sediment Control Requirements as outlmed in Volume II of the 2001 edition of the Stormwater Management Manual. Water: This project is required to provide separate domestic water service stubs for the new lots prior to recording the short plat. New water service stubs must be installed prior to recording of the short plat. Water System Development charges are based on a rate of $1,956 per new single-family lot (estimated total 0[$1,956.00 with credit for the existing lot). Payment of fees is required prior to issuance of utIlity construction permit. All plats are required by City Code to provide a fire hydrant with a minimum fire now requirement of 1,000 GPM within 300 feet of any proposed single-family structure. If the proposed Single-family structures exceed 3,600 SF, the minimum fire now increases to 1,500 GPM and requires two hydrants within 300 feet of the structurc. Any existing hydrant counted as fire protection will require installation of a "storz" quick disconnect fitting ifnot already in place. It appears an existing hydrant at the comer ofN. City of Renton PIB/PW Department Administrative Land Use Action TEETS SHORT PLA~ PROJECT LUA 07-101, SHPL-A REPORT AND DECISION Dated October 17, 1007 Page 8 36'h and Meadow Avenue may be within 300 feet. The engineer is required to show location of all existing hydrants on plan sheets. A new hydrant may be required. Sewer: Installation of individual side sewers by the developer is required prior to recording the short plat; dual side sewers are not allowed. The minimum slope for side sewers is 2%. Sanitary Sewer System Development Charges are based on a rate of $1 ,0 17 .00 per new single-family lot (estimated total of $1,017.00 with credit for the existing lot). Payment of this fee will be required prior to issuance of utility construction permits, and prior to recording the short plat. H. FINDINGS: Having reviewed the written record in the matter, the City now enters the following: 1. Application: The applicant's short plat application complies with the requirements for information for short plat review. The applicant's short plat plan and other project drawings are contained within the of1icial land use file. 3. Comprehensive Plan: The subject proposal is consistent with the Comprehensive Plan designations of the Residential Single Family (RSF) land use designation. 4. Zoning: The proposal as presented complies with the zoning requirements and development standards of the R-8 zoning designation, provided all advisory notes and conditions of approval are complied with. 5. Subdivision Regulations: The proposal complies with the requirements established by the City's Subdivision Regulations provided all advisory notes and conditions are complied with. 6. Existing Land Uses: The short plat is consistent with development and uses surrounding the subject site, including: North: Residential Single Family (zoned R-8); East: Interstate Highway 405 South: Residential Single Family (zoned R-8); and West: Residential Single Family (zoned R-8). 7. System Development Charges: A Water System Development Charge, a Surface Water System Development Charge and a Sewer System Development Charge, at the current applicable rates, will be required for the each new single-family residence as part of the construction permit. 8. Public Utilities: The applicant will be required to install individual sewer and water stubs to serve the new lots. In addition, installation of a fire hydrant may be required. 1. CONCLUSIONS: I. The subject site is located in the Residential Single Family (RSF) comprehensive plan designation and complies with the goals and policies established with this designation. 2. The subject site is located in the R-8 zoning designation and complies with the zoning and development standards established with this designation provided the applicant complies with City Code and conditions of approval. 3. The proposed two lot short plat complies with the subdivision regulations as established by City Code and state law provided all advisory notes and conditions are complied vifith. 4. The proposed two lot short plat complies with the street standards as established by City Code, provided the project complies with all advisory notes and conditions of approval contained herein. City of Renton PIBIPW Department Administratiye Land Use Action TEETS SnORT PLAT, PROJECT LVA 07·/01, SHPL·A REPORT AND DECISION Dated October 17, 2007 J. DECISION: The Teets Short Plat, File No. LUA 07-101, SHPL-A, is approved subject to the following conditions: I. The applicant shall obtain a demolition permit and all required inspections completed for the removal of the existing house and garage prior to the recording of the short plat. Page9 2. In order to preserve and protect the one significant tree during utility and building construction the tree shall be fenced off around the drip line and a sign posted that the tree is to be preserved, and the location ofthe tree shall be indicated on all utility construction plan sheets. The fencing shall be in place prior to the issuance of any utility construction permits and shall remain until the final inspection of the new house on Lot 2 is complete. 3. The applicant shall submit a revised, detailed landscape plan indicating the required street trees. The plan is subject to the review and approval ofthe Development Services project manager and is required prior to the issuance of the building permits. 4. The applicant shall pay the required Transportation Mitigation Fee based on $75.00 per net average daily trip prior to the recording of the short plat. 5. The garage access easement (Rec. #9312102007) shall be relinquished prior to recording the short plat. 6. The applicant shall adhere to the recommendations of the geotechnical report from Geotech Consultants, Inc. (dated July 27,2007). 7. The applicant shall pay a $488.00 Fire Mitigation Fee prior to the recording of the short plat. 8. The project shall be required to comply with the Department of Ecology's Erosion and Sediment Control Requirements as outlined in Volume II of the 200 I edition of the Stormwater Management Manual. DATE OF DECISION ON LAND USE ACTION: TRANSMITTEf) this 161h dayafOctober, 2007 to the Applicant/Owner/Contact: Applicant: Darcey Teets 2838 l09th Avenue SE Bellevue, WA 98004 O\vnl.!r: Denney and Robin Teets 3 S. flollow Road Dix Hills, NY 11746 Contact: Joe Hopper, P.E. Pacific Enjineering Design, LLC 1544553' Avenue, S. Suite [00 Owner: Doris 1. Pease 16205 SE 9th Street Bellevue, W A 98008 TRA.NSMITTED this 161 ;' day o/October, 2007 to the Parties of Record" There arc no parties of record. City of Renton PIB/PW Department Administrative Land Use Action TEETS SHORT PLAT, PROJECT LUA 07-101, SHPL-A REPORT AND DECISION Dated October /1, 2007 TRANSMfTTED this 16'" day DJOetDber, 2007 to theJollowing: Larry Meckling, Building Official Bob Van Home, Deputy Fire Chief Neil Watts, Development Services Director Jennifer Henning, Current Planning Manager Jan Conklin Carrie Olson Ren ton Reporter Land Use Action Appeals & Requests for Reconsideration The administrative land use decision will become final if the decision is not appealed within 14 days of the effective date of decision. An appeal of the decision must be filed within the 14-day appeal period (RCW 43.21.C.075(3); WAC 197-11-680). Page 10 RECONSIDERATION. Within 14 days of the effective date of the decision, any party may request that a decision on a short plat be reopened by the Administrator. The Administrator may modify his decision if material evidence not readily discoverable prior to the original decision is found or ifhe finds there was misrepresentation of fact. After review of the reconsideration request, if the Administrator finds insufficient evidence to amend the original decision, there will be no further extension of the appeal period. Any person wishing to take further action must file a formal appeal within the following appeal timeframe. APPEAL. This administrative land use decision will become final if not appealed in writing to the Hearing Examiner on or before 5:00 PM on OCTOBER 31,2007. City of Renton Municipal Code Section 4- 8-110 governs appeals to the Examiner. Additional information regarding the appeal process may be obtained from the Renton City Clerk's Office, (425) 430-6510. Appeals must be filed in writing, together with the required $75.00 application fee, to: Hearing Examiner, City of Renton, 1055 South Grady Way, Renton, WA 98055. EXPIRATION DATE: The Short Plat approval will expire two (2) years from the date of approval. An extension may be requested pursuant to RMC section 4-7-080.M. City of Renton PIBIPW Department TEETS SHORT PLAT) PROJECT LVA Oi~101, SHPL-A REPORT AND DECISION Dated October 17, 2007 ADVISORY NOTES TO APPLICANT Administratiye Land Use Action Page 11 The following notes are supplemental information provided in conjunction with the administrative land use action. Because these notes are provided as information only, they are not subject to the appeal process for the land use actions. Planning 1. RMC section 4-4-030.C.2 limits haul hours between 8:30 am to 3:30 pm, Monday through Friday unless otherwise 2. approved by the Development Services Division. The Development Services Division reserves the right to rescind the approved extended haul hours at any time if complaints are received. A detailed landscape plan shall be submitted at the time of building pennit application. The landscape plan will include ornamental trees in the front yard of each lot and the 5' foot landscape strip. 3. If more than 500 cubic yards offill is moved, Environmental Review (SEPA) will be required. Property Services 1. To be sent under separate cover. Fire 1. A fire hydrant with 1,000 GPM tire flow is required within 300 feet of all new single-family structures. If the building square footage exceeds 3,600 sq. ft. in area (including garage), the minimum fire flow increases to 1,500 GPM and requires two hydrants within 300 feet of the structures. The applicant should note that the fire flow available to the site is 1,000 GPM, therefore no residences over 3,600 SF in area can be pennitted on the subject site due to the limited fIre flow available. 2. All building addresses shall be visible from, or posted at, the public street. 3. Any existing hydrant counted as fire protection will require installation ofa "storz" quick discOlmect fitting ifnot already in place. It appears an existing hydrant at the corner ofN. 36'h and Meadow may be within 300 feet. The engineer is required to show location of all existing hydrants. A new hydrant may be required. Plan Review -Sewer 1. Sanitary Sewer System Development Charge is $1,017.00 per new single-family lot. Payment of this fee will be required prior to issuance of utility construction permit. 2. Separate sewer stubs arc required for each new lot prior to recording of the short plat. 3. Minimum slope for side sewers shall be 2%. Dual side sewers are not allowed. Plan Revic\v Surface Water 1. The Surface Water System Development Charges are based on a rate of$759.00 per new single-family lot. Payment of this fec will be required prior to the issuance of a utility construction permit. 2. Roof drains shall be tight lined to the stom1 system whenever feasible. i 3. A conceptual drainage plan and narrative is required. This project is exempt from detention and water quality per the 1990 KCSWM. 4. A temporary erosion control plan will be required and shall be installed and maintained to the satisfaction of the representative of the Development Services Division for the duration of the project. Plan Review -Streets/Transportation. 1. Half street improvements including sidewalk, curb, and gutter, paving and stonn drainage are required to be installed fronting the site in Meadow Ave N. Applicant may submit a request to Public Works to pay a fee in lieu of installing these improvements. 2. Applicant will be required to dedicate five feet of right-of-way fronting the site in Meadow Ave N. Existing right of way width is 40 feet. Minimum right of way width is fifty feet. It is shown on the plans. 3. Street lighting is not required for a two lot short plat 4. Applicant will be required to comply with the City of Renton's Trench Restoration and Street Overlay Requirements. 5. A traffic control plan, approved by the City will be required for any construction impacting the City's right of way. 6. Maximum driveway slope is 15%. l"vfiscellaneous l. Separate permits and fees for side sewer comlections, water meters, and stann drainage connections are required. 2. Applicant shall be responsible for securing all necessary easements for utilities. 3. Proposed new rockeries or retaining walls to be constructed that are greater than four feet in height (from bottom of footing to top or wall) will be require a separate building pennit for structural review_ A geotechnical report is required \\lith the submittal. 4. All wire utilities shall be mstalled underground per the City of Renton Under Grounding Ordinance. If three or more poles are requlfed to be moved by the development design, all existing overhead utilities shall be placed underground. B4 • 29 T24N R5E W 112 I I I " I( CDR / R-8 R-8 N 37th ,'<:! I~R-S N33td· prR~81 ~' "R~~S /.£ R-S N3.31 d 3t 1m :-: II~ R-S .N3211d St R-S l~ 31St 3t R-S I I R-S/ R-S/ CD I R-8:Z; l1:: Q.) :>. St<: R-8 N 34th St R-8 N 32mi St. R-8 1I=":i~=-i ER-S N 30th Sf R-Siii{ f-------'-C-N--f 1F.Fiii==9IR -8 N 29th St R-~ f-C_N----; CN R-8 I R-S. ~=l _ H 2tltJI PI R-S R-S R-S 'l' R~8 R-4 '" D4 . 5 T23N RSE W 112 CA CA NE 43 <J: U ~ :z; Q.) :> <: CA 'r----, 'A;ijc:~~., CN "<:~; , o 200 ","00 C4 1:4800 ~ ZONING o = TiCIINICAL SD.V1Cl!9 32 T24N R5E W 112 5431 r LOO: ~ PORTION OF THE S,E, 1/4, N. W. 1/4, SECTION 32, TWP. 24 N., RGE. 5 E., w.M. ~ K11lG COU1lTY, l'.A.!OONGfON ~ I ., / I .. "'/ I ~ / LOT 1 ~ I 0 I" / oL I Q .. 1':/ '" #" ::a '" gl #0\ I 20' ! 20' I # I LOT 2 CERTIFICATE SHORT PLAT NO. LUA-XX-XXX-SHPL i -$- I" = 30' LND-D-DIX 0' 30' 60' ....... ' .... /~ II£AAlNa 'wlImCAL C1ATUIII IS NAW laM. SIT[ ~ 31112 Il£APOW AVE N., RENTON, W... N05t CRIOlNAL TrU: PloJIcti. , .l3427OD117 I ('lIE) MERDY CER1n THAT I AM (WE ARE) THE O'/f£R(S) IN I'U SUoIPLE Of THE .... WD 1l:E~[8Y p ..... mp IN TItS SHOIIT PLAT. ----------~----LEGEND SS _ !WIITAAY SlWER sri _ STOfIIri SEWER D .. IIoI.S UNt ~~1: ~DJ~RDsJE~~ttH~*D lIND WIFE ACKNOWLEDGWENT -------------SlATE Of" WASHIN~TIJN) I I COUHTY Of ~IHG )}SS l{)1 ~I 0tP_ O'/ERlto./) I'O'/rER LlH£ W _ ....... rm lnIE (II -OA$ YAL'II; e -WA1'I:R YAL'II: III _ W ... lER IrIETDt \:I" .. f1R£ HlDllANT • .. c.\lCH 1I1&~ o .. 1WIHDi.£ -0 .. uruTY PCU (I-.. UGHT POST ~ .. GUY NICHOll ~--IE] _ POWER YAULT/llIAl<5FIlRWER m -ltLE./lY PEll. 001 THIS PH PERsoti.w. k -:t'K: ~~ ~E ,~=~,.;(.")'~",",",-~"ru" .• " THE fORE~ INSTiWMENT. NlD Jt,CKNow...EDGEll ntAT $AID IN5TRUWENT TO BE lHE rilE£: 1H:J WWNTARY ... 01 lIND DEED D~ 'JloIE SoI.IO PEIISQI<I(5), roR 1H£ USES -'NO PUllP05ES THEREIN WElo/TIONED. AND ON OATH ST ... TED TlIAT 'll<EY 'ilERt: ~U1HORllEO TO [J([CUTE l"r1E S~O IHSno:UIoIEI'IT. GI~ UIoID£R NY HAND NlD stAL lIIIS _ DAY Of 2007 illilARY PIlBUC IN iON(l fOR 1HE STATE Of W,\SHIt.lQTON RESIDIIoIG ... T --=t-----e .. P/IJ!l(INO W£'lER • _ S£CTION ~ Z .. QlJAATER ~NER e .. FIID. WON. I~ CASE o .. FHa. PROP. COlt AS ~QlU) • .. S£T 1/2' LR. W(CAP I2HM (COlI) ~ QTY OF IlVlTO~ (R) _ R£CORl) APPROViJ.S CITY OF RENTON [)C,I,I,IINED ANti J\PPROIIED THIS __ D.o,T Of ____ 2007. I ADMINISTRATOR OF PlANNING/llUIlllING/PUBUC WORKS XING COUNTY I ". LOT 121 EX.I.Io!IPlEO !lN0 APPROI'ED lHIS __ DAY Of ____ "'"'. [l[pAliTWENT OF" A5Sl:SSIoIENTS KINO COU'-'TY A$S£SSOR ()(PAR'Jl.IENT or .o.ssESSIoIEN'lS DEPUTY KlNC COUNTY ASSESSOR ro I '" y-' --------~---- LEGAL DESCRIPTION PER RMlIER T1TU" COIoIP.t.NY. E~£ TITLE UNIT, REPORT ORDER No. -405H1 DATU .o.uOUST e. 200II. lR.OCI' 12.2 OF C..D. hl.J..l.W(S LAkE ~ QAAODj Of [tl(N ADDnlOH 1D SE<.m.E tID. 2. M PER PLAT RECORDEO It< WUJIoIi: 11 Of PlAlS, PADt: 14, RECORDS Of ~IHG OOUHIY AlJDrTOR: EXCEPT 'fII,U POIITION lYING WITHIN !lEC()NIWl'r' STAlE HIGHWAY Nl,IIoI8EII 2-1.: SlruAlE !/oj ThE QOI..IHIY OF 1CNl, $'101.'1'1: OF WA5HNG'TON. LOT AREAS LOTI "n, 5' ROW D£l)Ic.o.T1OH ~l~~Pl.Al 5,880 s.r_ OR 1I.'4.t. "'/- 5,733 s.r_ OR a.ll M.. "'/- i).lB s.r. OR 11.1)1 M.. "'/- ,2,'5' s.r. OR 0.28 M.. +/- DECLARATION OF COVENANT Lor 1 LOT 2 "IlIE OIII'NER Of nt£ UNO DlBRIoC£D wm-JI,I THIS $HCIIIT PLAT, IN IIE1UI'IN fOR H IlENEflT 10 ACCR\.I£ F1IOIO THIS SU8DlIGOtI, BY SIIiHNG HPWlN CCMHANTS NlD _ED TO CON\'EY fI<E 1llENEFlCW. IIIlDI£Sl III 1H£ N£W ~T _ ON lMS SHORT Pl.AT TO ANY AND ~L1. NTIJRf PURCI!ASEIIS OF lH£ LOTS, OR Of" N-IY 5IJlIII~ 'IttER£Of. ntiS COIOIANT SH.I.LL RtIoI 'Mnt 1ltE L.AII) AS SIlO. I;N "IHIS !HIIIT PLAT. RECORII~S CRR1'IFlCJ..TE NEW LOT ADDRESSES wu.oow A'IE ~ R£NTOII. 'fIA 9~ t.IEAClOW .1'[ N, ROITOII, IItA Q~ 5LlR'IEY Ytt1'S Ill! tXCE£OS 1H£ R[QUI/IEIIlHTS Of" ~ Ml-l»-OIIO. EQUINENT USED; ~. TOTIoi. STATION. SUR'IEY IIIrntOO: fl£U) 1lIAI€RSE. 1IQ.A1I'IE F'05I1ION1oi. T!:ILflWIC[ Of SET CORM£JIS:-4/_0.1' TEETS SHORT PLAT 8tmyIyDR'8 CJ:EmnCt.TE' ; THIS loW' COotl~fCTLY REI'RESENlS • 9..1111£'1' 010\0£ BY 101£ 011 UllOElt 1I'f DI~ ~ ~~1H '!11£ 'R£Ql,IlREIIENlS OF ntE SUR\£'( m.ED '011 ~COIID ntiS __ DAr Of 20_ ... T ----114. IN 8001( ___ ~ ____ H PAC( ___ _ S.E. 1/4, N.W. 1/4. SEC. 32, TIP. 24 N" RGE, 5 Eo, W,1ot CITY OF RENTON, KING COUNTY, WASHINGTON RECORDING AClrU'?H * '~~;;:~:fJ>.{::.:<~., .. '.;.,:." '·i;:\""':"·:'~'-:' .. 4., .... ,'t.:;,.,,~iIOil/i"';'d IU.N!iDI -, '. ,~-"'. ,·7 ... .,."'''.,.." '. (. f. .... ~ 't/-;:, .;, r'''''' -. .... , . AT lHt R£QUt5T OF ROtlNtv G. l;ANS£jj. -QtR SUPT. Of ItECORDS CITY OF RENTON FlLE No. WL OWN BY: PJe DATE: 5/14/07 I JOB NO. 20714 CHKD BY: RGH SCALE: 1~-20' SHEET 1 OF 1 ..... ~JIT. CIVIL ENGlNEER: rJfP.&oEf~ D£S.IGN, u.c IIirI PIN 1'ttONC:(7OB) 4l'-JllJO F.u:(2Od) ,..."" SURVEYOR; HAlfSEN SURVE'fiNG '742'J 118lN AloE .s£ RD/TCW, ~-""(IN£; (~') 2~ r.u: (42') 2~Q2N ~~ UlltST R(VI5IQN; 05/14/07 A HANSEN SURVEYING IJJ.ID SlIA'£Y<:lIIS rl!: CONStlLTANTS 17.nt1 1l81H All£... s.E., RDtTOH, WA IIao58 tEL: -4@-ZJ.:i-e+40 'AX: 425-al5-OHl ~ • III I I ~ ~I-I " ~~ , " f . i ~a.. ¥ , I!i~ I ! 1/~ I ~ t !, fl' · i~ : I • I I II till I I . I I .• ~(f) ! 111r1 !! ~I--I d w ~w I -U ~I-.J I ~ " I" I I' b e ~!I i ~ iii 10 a: Z ~ f-' ~ ~ II! .f .... ~ ~ t ~ III w j!: IL 0 Z 0 ~ ~ · "", f - I I I ~ 'h -c z: : U ---1 -- I I I -_ 0-_-=--_:-. __ --_ -0 .: .. Ii ..J , , I~ . ..". \. , T==~~~~=~="f-~"=---=.-""l i~~' , 1m' i~ . i!1 9OV-/ -l-----l.- I -; !: ~ .' . ~ ,. . -, (.'" ,,' ,~~ ,. ,._ > ~: ----::::;: .. i-J .~ :r;. C> ~~: tJ,i , ,. ,.:~ . ';.."";' -" ~ '" , , .. l:'..--- -l ----. .uIOHS 9.L33.l -~ I I ----- I I I I I ----1 - I I I ---1_ Denis Law Mayor May 27,2009 Joseph Hopper, P.E. Project Manager Pacific Engineering Design, Inc. 15445 53'd Avenue 5 #100 Seattle, WA 98188 SUBJECT: Request for Extension of Project's Period of Validity Teets Short Plat / City of Renton File LUA07-101, SHPL-A Dear Mr. Hopper: This letter is sent in response to your request for an extension of the above referenced project's approved period of validity. Section 4-7-070M of the Renton Municipal Code, relating to short plats, authorizes the City to approve a single one-year extension of the usual two-year expiration. Under Ordinance No. 5452 (RMC 4-1-080F) authorization has been given to the Planning Director to approve an additional two-year extension beyond the standard extensions possible under the Code for any land use or subdivision project that was valid on or after April 1, 2009. Our records indicate that this project will expire on October 17,2009. We understand that you are still working to complete this project and will require additional time. Therefore, your request for the standard one-year extension and the additional two-year extension under Ordinance No. 5452 is hereby granted. You now have until October 17, 2012 to complete and record this project. You should be aware this is a one-time only extension and if the project is not completed and recorded by the new expiration date it will become null and void and you will need to resubmit all application materials. I hope this extension meets your needs and that your project can be completed. You may call Laureen Nicolay at (425) 430-7294 if you have any further questions. Sincerely, \ I C-£_ V v---'--~ C.E. "Chip" Vincent Planning Director cc: Darcey Teets / Applicant City of Renton File No. LUA07-101, SHPL-A Jennifer Henning, Current Planning Manager Jan lilian, Plan Reviewer Renton City Hall • 1055 South Grady Way • Renton, Wa5hington 98057 • rentonwa.gov " PACIFIC ~NGINEERING DESIGN, LLC;=====: :::::::::; J .CIVI L ENGIN EERING AND PLANNING CONSULTANTS I May 21,2009 C.E. Vincent City of Renton Department of Community & Economic Development lOSS South Grady Way Renton, WA 98057 Subject: Teets Short Plat Expiration Extension City of Renton File LUA07-101, SHPL-A Dear Mr. Vincent: Project No.: 06089 I would like to request the standard extension of one (I )-year for the above referenced application under RMC 4-7-050M of the Renton Municipal Code, as well as the additional two (2)-year extension under Ordinance No. 5452. If you have further questions, please contact me at (206) 431-7970. Best Regards, IJ oseph Hopper, P.E. roject Manager www.paceng.com 15445 53RD AVENUE SOUTH, SUrTE100,SEAl'TLE, WA 881 SB FAX 206388-1648 PHONE425251-BB11 206431-7970 =PACIFIC ENGINEERING DESIGN, LLC= S:EI',nLE VIlA 981 CIVIL ENGINEERING AND PLANNING CDN5ULTANTo 22 1'4AY z":uJ PM 7 T --...: j~~''''''''""",::~:~'", 15445 53RD AVENUE SOUTH, SUITE 100 SEATTLE. WA 9B1 SS ~'::iEiO!!.::;7:±:.3:'"232 CCi.i::I9 1" I J I III j ,Ii I I I ,I, j ,1111 i I I I j I I I j I i I I 1 J I I I J I 1,1 , I, I" J II II III Denis Law Mayor May 18, 2009 Joe Hopper, P .E. Pacific Engineering Design, LLC 15445 53rd Avenue 5 #100 Seattle, WA 98188 Department of Community & Economic Development SUBJECT: Expiration period for Teets Short Plat City of Renton File LUA07-101, SHPl-A Dear Mr. Hopper: The City of Renton Planning Division approved the above referenced application on October 17, 2007. This approval is ordinarily good for two (2) year(s). Pursuant to RMC 4-7-0S0M of the Renton Municipal Code, you may upon written request, prior to the expiration of the project, receive a single one (l)-year extension from the Planning Division. In addition to the above one (l)-year extension, the City Council under Ordinance No. 5452 (enclosed), has granted an extension o/the period o/validity on lond use and subdivision approvals. Therefore, certain land use and/or subdivision approvals expiring after April 1,2009, upon written request and prior to the expiration of the project, may receive an additional one-time two (2)-year extension beyond the standard expiration date listed in RMC 4-8 and RMC 4-9. Our records indicate that the above referenced application will expire on October 17, 2009. This letter is to inform you that prior to the expiration date of this project, you may submit a written request for the standard extension the project would normally receive under RMC 4-7, RMC 4-8, and RMC 4-9, as well as request the additional two (2)-year extension under Ordinance No. 5452. Please be aware that this extension does not apply to temporary use permits, building permits, or public works permits. Also, this provision shall automatically expire on December 31,2010, and shall be removed from the code at that time unless another ordinance is passed extending this date. If you have any further questions, please feel free to contact Laureen Nicolay at (425) 430-7294. Sincerely, \J~. C,Z-- C. E. Vincent Planning Director Enclosure: Copy of Ordinance #5452 cc: Darcey Teets / Applicant City of Renton File No. LUA07-101, SHPL-A Chip Vincent, Planning Director Jennifer Henning, Current Planning Manager Neil Watts, Development Services Director Kayren Kittrick, Development Engineering Supervisor Renton City Hall • 1055 South Grady Way • Renton, Washington 98057 • rentonwa.gov April 15,2008 Mr. Darcey Teets 2838 109th Avenue SE Bellevue, Washington 98004 Re: Teets Short Plat 3612 Meadow Avenue North Renton, WA 98056 Dear Mr. Teets: On April 15,2008, the Development Services Director granted your application for a fee-in-lieu of installing offsite improvements consisting of sidewalks, curb, gutter, and pavement fronting the site in Meadow Avenue North. The fee for improvements has been calculated as follows: FEE PER SQUARE YARD # SQUARE (SY) OR LINEAL YARDS OR ITEM FOOT (LF) LINEAL FEET EXTENDED COST Sidewalk fronting Meadow Avenue North 38.001LF 108 $4,104.00 Curb and Gutter Meadow Avenue North 48.00/LF !O8 $5,184.00 TOTAL FEE-IN-LIEU OF DUE CITY OF RENTON $9,288.00 This fee must be received by the City prior to recording of the short plat. According to City code, you have 15 days from today's date to appeal the administrative determination. Appeals are to be filed in writing, with the City Clerk and require a filing fee in the amount of $75.00. Additional information regarding the appeal process may be obtained from the Renton City Clerk's office by calling (425) 430-6510. If you have any questions or need additional information, please contact Mike Dotson, Engineering Specialist at (425) 430-7304. Sincerely, Linda Moschetti Administrative Assistant Public Works Department cc: Gregg Zimmerman, Public Works Administrator Neil Watts, Director, Development Services Mike Dotson, Engineering Specialist Jan Illian, Engineering Specialist Denis Law Mayor May 18, 2009 Joe Hopper, P.E. Pacific Engineering Design, LLC 15445 53rd Avenue S #100 Seattle, WA 98188 Department of Community & Economic Development SUBJECT: Expiration period for Teets Short Plat City of Renton File LUA07-101, SHPL-A Dear Mr. Hopper: The City of Renton Planning Division approved the above referenced application on October 17, 2007. This approval is ordinarily good for two (2) year(s). Pursuant to RMC 4-7-050M of the Renton Municipal Code, you may upon written request, prior to the expiration of the project, receive a single one (1)-year extension from the Planning Division. In addition to the above one (l)-year extension, the City Council under Ordinance No. 5452 (enclosed), has granted an extension a/the period a/validity on land use and subdivision approvals. Therefore, certain land use and/or subdivision approvals expiring after April 1, 2009, upon written request and prior to the expiration of the project, may receive an additional one-time two (2)-year extension beyond the standard expiration date listed in RMC 4-8 and RMC 4-9. Our records indicate that the above referenced application will expire on October 17, 2009. This letter is to inform you that prior to the expiration date of this project, you may submit a written request for the standard extension the project would normally receive under RMC 4-7, RMC 4-8, and RMC 4-9, as well as request the additional two (2)-year extension under Ordinance No. 5452. Please be aware that this extension does not apply to temporary use permits, building permits, or public works permits. Also, this provision shall automatically expire on December 31, 2010, and shall be removed from the code at that time unless another ordinance is passed extending this date. If you have any further questions, please feel free to contact Laureen Nicolay at (425) 430-7294. Sincerely, \J ~ C.Z- C. E. Vincent Planning Director Enclosure: Copy of Ordinance #5452 cc: Darcey Teets / Applicant City of Renton File No. LUA07-101, SHPL-A Chip Vincent, Planning Director Jennifer Henning, Current Planning Manager Neil Watts, Development Services Director Kayren Kittrick, Development Engineering Supervisor Renton City Hall • lOSS South Grady Way • Renton, Washington 98057 • rentonwa.gov 1 Denis Law, Mayor November 24, 2008 Darcey Teets 2838 109 th Ave SE Bellevue EA 98004 CITY SUBJECT: TEETS SHORT PLAT LUA07-10!-SHPL Dear Mr. Teets: F RENTON Department of Community and Economic Development Alex Pietsch, Administrator The review submittal on the above-mentioned short plat has been completed and the following comments have been returned. Please review these comments and make the necessary changes. Once changes have been completed please resubmit three copies of the short plat drawings and three copies of any other related documents. SHORT PLAT REVIEW COMMENTS: I. Contact Jan Illian, Plan Reviewer, at 425-430-7216, for requirements to be completed on the civil construction portion to your project. 2. DEED OF DEDICATION NOTE: The dedication of land for street purposes on the short plat (the 5' strip adjoining Meadow Ave N) requires approval by the City Council. Said dedication is achieved via a recorded City of Renton Dedication Deed document. If the dedication is to be recorded with the short plat, the dedication process needs to be timed in such a way that Council approval and all other matters pertaining to the dedication have been addressed and resolved, and said document is ready to record. The Deed of Dedication document includes both a legal description exhibit and a map exhibit. The legal description exhibit should be prepared, stamped, dated and signed by the applicant's surveyor. The surveyor should also prepare the map exhibit. The first page of said document needs to include an abbreviated legal description. The dedication process requires an updated title report Plat Certificate document, dated within 45 days of Council action on said dedication. Talk to the Project Manager if there are questions or further information is needed. 3. Note the City of Renton land record number, LND-20-0499, on the drawing sheet in the space already provided. 4. Note all easements, covenants and agreements of record on the short plat drawing. Include Rec. No. 4695952 on the short plat submittal (relinquishment of all easements for access, light, view and air), as it is listed under the "EXCEPTIONS" section ofthe title report. 5. The addresses for the lots are: Lot 1 is 3616 Meadow Ave N, Lot 2 is 3610 Meadow Ave N. Note said addresses in the spaces already provided on the submittal. ___ I_:IP_I_anR_eVl_'e_wl_CO_LS_O_N\S_ho_rtp_l_ats_2_00_8_IT_eets_S_HP_L_02_L_C_honge __ RCQ_uestS_to_p_.d_oc _______ ~, 1055 South Grady Way -Renton, Washington 98057 ® This paper contains 50% recycled material. 30% post consumer AHEAD OF THE C.URVE , June 19,2008 Page 2 6. The current short plat submittal shows that Darcey Teets is the property owner. Note that all vested owners of the property, at the time of recording, need to sign the final short plat submittal. Provide notary blocks as needed. 7. Note the Basis of Bearing on the submittal. 8. Change the name of the "CERTIFICATE" block to OWNER'S DECLARATION. 9. Remove the building setback lines from the short plat drawing and the "LEGEND" block. Setbacks will be determined at the time that building permits are issued. 10. The City of Renton Administrator, Department of Public Works, is the only city official who signs this short plat. Note that this is a new title. I I. Show a horizontal line between the approvals for the City of Renton and King County to give better separation between the two. 12. Remove the "SITE ADDRESS" block. 13. See the attachment for circled items to address. 14. Please provide an updated short plat certificate. IS. The intent ofthe owner is to dedicate property to the city for street purposes. Please submit a Deed of Dedication document and executed REETA form to the city. Should you need to discuss any portion of this letter please contact me at (425) 430-7235. Sincerely, {rl~;'>/~~ ~((OfJA'/! Carrie K. Olson Development Services, Plan Review /FAXED TO; Joe Hopper, P.E., Pacific Engineering Design, LLC: 206-388-1648 cc; Yellow File :0 :1 20' 25' FENCE 1.8' S 3.6' W FNO IRC #"332 0.09'5 & O.03'E OF CALC. COR. WTl 1.0':1'2 COVERED 3.5' CHAIN CONCRETE LINK FENCE EAVE ~ SHED Co ~-L2c..--=:-,,;,(_ ~~=i:.:::-;.~~~~S~.~B~8·,;:;44::,'~0:~~ ~E;",,,,1,:,.1:;5;;,;.6;;;6,..,' T _"'-"'-....... "'-.,,....~-~. ~ r (5 B8"42'07"E 1lt,79'-SP 194/11) '"' q I I I ,OY I ---11),66'--1 :g , I ( , 5' RIGHT OF WAY <0 ROOF DEDICATION 1:t--j:.....:.~--:--.J~5J' 10' FRONT Yi,RD OVERHANG 5' RIGHT OF WAY DEDICATION 20' 25' '&:i' Q.. _ I / BSBL (TYP, , 2.0'5 I r,.., I OJ / LOml 1 v~b-"; I ,,!~l() r-. o L 5' I! 1 1 , r-L1 ~ \ I 25' 'In o -N 5'SIDE YARD -'·S8L (:~ i : FENCE 0.2' S , 20' Rf-"R YARD BSBL (TYP.) ~ LOT 2 I 125,00' -1-- ~FENCE 1.0' S ROOF OVERHANG 2.0'5 SET IRC #21 2.0' OFFSE LD o -.:t / ~CONC. SOU BARRIER WI -+-125.00' , .. ~ .. DATE: TO: FROM: SUBJECT: PUBLIC WORKS DEPARTMENT MEMORANDUM November 24, 2008 Carrie Olson Sonja J. Fesser y~ Teets Short Plat, LUA-07-101-SHPL Format and Legal Description Review Bob Mac Onie and I have reviewed the above referenced short plat submittal and have the following comments: Comments for the Applicant: DEED OF DEDICATION NOTE: The dedication of land for street purposes on the short plat (the 5' strip adjoining Meadow Ave N) requires approval by the City Council. Said dedication is achieved via a recorded City of Renton Dedication Deed document. If the dedication is to be recorded with the short plat, the dedication process needs to be timed in such a way that Council approval and all other matters pertaining to the dedication have been addressed and resolved, and said document is ready to record. The Deed of Dedication document includes both a legal description exhibit and a map exhibit. The legal description exhibit should be prepared, stamped, dated and signed by the applicant's surveyor. The surveyor should also prepare the map exhibit. The first page of said document needs to include an abbreviated legal description. The dedication process requires an updated title report Plat Certificate document, dated within 4S days of Council action on said dedication. Talk to the Project Manager if there are questions or further information is needed. Note the City of Renton land record number, LND-20-0499, on the drawing sheet in the space already provided. Note !ill easements, covenants and agreements of record on the short plat drawing. Include Rec. No. 4695952 on the short plat submittal (relinquishment of all easements for access, light, view and air), as it is listed under the "EXCEPTIONS" section of the title report. The addresses for the lots are: Lot I is 3616 Meadow Ave N, Lot 2 is 36\0 Meadow Ave !:{. Note said addresses in the spaces already provided on the submittal. The current short plat submittal shows that Darcey Teets is the property owner. Note that all vested owners of the property, at the time of recording, need to sign the final short plat submittal. Provide notary blocks as needed. \H:\Filc Sys\LND -Land Subdivision & Surveying Records\LND-20 -Short Plats\0499\RV081120.doc , " . November 24, 2008 Page 2 Note the Basis of Bearing on the submittal. Change the name of the "CERTIFICATE" block to OWNER'S DECLARATION. Remove the building setback lines from the short plat drawing and the "LEGEND" block. Setbacks will be determined at the time that building permits are issued. The City of Renton Administrator, Department of Public Works, is the only city official who signs this short plat. Note that this is a new title. Show a horizontal line between the approvals for the City of Renton and King County to give better separation between the two. Remove the "SITE ADDRESS" block. See the attachment for circled items to address. Comments for the Project Manager: The approval slip, dated November 12, 200S, notes that a short plat certificate is enclosed in the review package. However, the short plat certificate does not appear to be with the other attachments. Please provide the certificate. The intent of the owner is to dedicate property to the city for street purposes. Has a Deed of Dedication document been submitted to the city? H:\File Sys\LND -Land Suhdivision & Surveying Records\LND-20 -Short Plats\0499\R VOSI120.doc\cor DATE: TO: FROM: SUBJECT: CITY OF RENTON PLANNINGIBUILDINGIPUBLIC WORKS MEMORANDUM November 12, 2008 Bob Mac Onie, Technical Services Sonja Fesser, Technical Services Carrie Olson, Plan Review X7235~ TEETS SHORT PLAT LUA07-101-SHPL cCS -(ycfc;C! AND LEGAL REVIEW Attached is the most recent version of the above-referenced short plat. The following attachments are enclosed for your review: • Lot Closures • Short Plat Certificate • Garage Relinquishment Recorded Document • Short Plat drawings If all review concerns have been addressed, please sign below or return your comments as needed. Thanks. Approval: c:-:----=-=-=--::-.,--:------\'--c::--:-=:-------, Date: ____ _ Robert T Mac Onie, Jr. Sonja Fesser Ce: Y tHow File I:\PlanReviewICOLSON\Shortplats 2008ITeets SHPL Olm PR-TS RcviewStart.doc DATE: TO: ROUTE TO: FROM: SUBJECT: CITY OF RENTON PLANNINGffiUILDINGIPUBLIC WORKS MEMORANDUM November 12, 2008 Jan lilian, Plan Review Kayren Kittrick, Plan Review Carrie Olson, Plan Review TEETS SHORT PLAT LUA07-101-SHPL Attached is the most recent version of the above-referenced short plat. If all review concerns have been addressed, please sign below or return your comments as needed. Thanks. Attachment included: Garage Relinquishment Recorded Document, Lot Closures, Short Plat drawings Also provide the following information requested by Gregg Zimmermen as requirement of project closeout and signing of short plat mylars. Status Of: ~ &1m!!. ~ ~[2iw!!! Comments As·Builts Cost Data Inventory Bill of Sale Easements 1. Garage Relinquishment Recorded Document (Water, Sewer, Utilities, Hydrant, etc.) Deed of Dedication Square Footage: 538.09 Deed has not been submitted 1. yet. Restrictive Covenants 1. Maintenance Bond Release Pennit Bond Comments: Approval: ::::------,-:-:---:-:--------~-----,-c--------" Date: ____ _ Kayren Kittrick Jan Illian Cc: Yellow File To: EngineEJ.lJjjY Design, Llr; CIvil Engineering i:: Planning ConsultaU!$ City of Renton 1055 S Grady Way Renton, W A 98055 Site Location: 15445 53'd Ave S Seattle, W A 98188 Letter of Transmittal Mailing Address: PO Box 24060 Federal Way, W A 98093 Phone: (206) 431-7970 Fax: (206) 388-1648 Website: www.paceng.com Date: September 15, 2008 Attn: Carrie Olson Job No: 06089 Project: Teets Short Plat We Are Sending You: Final Plat Submittal Copies No. 3 I 3 4 3 I I 2 Remarks: ----------------------------------------------------- Via: DFax Sheets Including Transmittal D Courier Hour Courier # Fax # D Mail [gJ Other Submitted at Counter Description Final Short Plat Plan (9/3/08) Lot Closures (8/28/08) Planting/Tree Retention Plan (LI) (11120/07) Garage Access Easement Relinquishment Recording #20080219001158 Enclosed for your review is the final short plat and associated documents. If you need anything else, please let me know. Thank you. Copy: File D Original __ 5130 __ 5135 __ 5136 CI1YOFAENTON RECEWED SEP 152008 BU IlDiNGDIVISION Signed: ~ 'PaM.di4e D File Copy __ 5137 __ 5140 __ 5152 D Billing Copy __ 5154 __ 5155 __ 5165 · "Sight" Survey 990601·Z-0701 Thursday, August 28, 2008 6:58 am. Pg: 1 Registered to: RODNEEY HANSEN File Name: K:\COGO\2007\20714.ASC Poiut Direction Distance Northing Database opened: Thursday, August 28, 2008 6:56 am. ORlGnvALLOTBOUNDARY Start 4220 7662.714 S 88°44'07" E 115.66 4221 7660.161 S4°34'19"W 107.77 4222 7552.736 N 88°45'0 I" W 110.19 4223 7555.139 Raw: l.3943NE 107.62 TC N 1°39'43" E 107.62 4220 7662.714 TC N 26°04'00" W 0.00 4220 7662.714 Precision Ratio = 1: 1.95E+06 Lengtb Traversed = 441.23 Lengtb To Close = 0.00 Error iu Latitude = 0.00 Error in Departure 0.00 Error in Elevation = 0.00 Area = 12150.567 Sq. Feet or 0.279 Acres Easting Elevation 9289.890 0.000 9405.518 0.000 9396.928 0.000 9286.769 0.000 9289.890 0.000 9289.890 0.000 · "Sight" Survey 990601-Z-0701 Thursday, August 28, 2008 7:00 am. Pg: 1 Registered to: RODNEEY HANSEN File Name: K:ICOGOI2007\20714.ASC Point Direction Distance Northing Database opened: Thursday, August 28, 2008 6:56 am. Eastiog Elevation RIGHT OF WAY DEDICATION BOUNDARY Start 4220 7662.714 9289.890 S 88°44'07" E 5.00 4235 7662.604 9294.889 S 1°39'43" W 107.62 4254 7555.030 9291.768 N 88°45'01" W 5.00 4223 7555.139 9286.769 Raw: l.3943NE 107.62 TC N 1°39'43" E 107.62 4220 7662.714 9289.890 TC N 26°04'00" W 0.00 4220 7662.714 9289.890 Precision Ratio I: 996592 Length Traversed = 225.24 Length To Close = 0.00 Error in Latitude 0.00 Error in Departure 0.00 Error in Elevation = 0.00 Area = 538.092 Sq. Feet or 0.012 Acres 0.000 0.000 0.000 0.000 0.000 0.000 "Sight" Survey 990601-Z-0701 Thursday, August 28, 2008 7:05 am. Pg: I . Registered to: RODNEEY HANSEN File Name: K:ICOGO\2007\20714,ASC Point Direction Distance Northing Database opened: Thursday, August 28, 2008 6:56 am, NEW LOT 1 BOUNDARY Start 4235 7662.604 S 88°44'07" E 110,66 4221 7660.161 S 4°34'19" W 53.88 4242 7606.448 N 88°44'33" W 107,92 4241 7608.817 Raw: 1.3943NE 53,81 TC N 1°39'43" E 53.81 4235 7662.604 TC S rI7'34"W 0.00 4235 7662.604 Precision Ratio = 1: 603239 Length Traversed = 326.27 Length To Close 0,00 Error in Latitude = 0,00 Error in Departure = 0,00 Error in Elevation 0,00 Area = 5879,837 Sq. Feet or 0,]35 Acres Easting Elevation 9294.889 9405.518 9401.223 9293.329 9294,889 9294.889 0.000 0,000 0,000 0,000 0.000 0.000 "Sight" Survey 990601-Z-0701 Thursday, August 28, 2008 10:44 am. Pg: 1 . Registered to: RODNEEY HANSEN File Name: K:\COG012007120714.ASC Point Direction Distance N ortlring Database opened: Thursday, August 28, 2008 6:56 am. NEW LOT 2 BOUNDARY Start 4241 7608.817 S 88°44'33" E 107.92 4242 7606.448 S 4°34'19" W 53.89 4222 7552.736 N 88°45'01" W 105.19 4254 7555.030 Raw: 1.3943NE 53.81 TC N 1°39'43" E 53.81 4241 7608.817 TC S 6°53'IO"W 0.00 4241 7608.817 Precision Ratio 1 :560231 Length Traversed 320.80 Length To Close = 0.00 Error in Latitude 0.00 Error in Departure = 0.00 Error in Elevation 0.00 Area = 5732.634 Sq. Feet or 0.132 Acres Basting Elevation 9293.329 9401.223 9396.928 9291.768 9293.329 9293.329 0.000 0.000 0.000 0.000 0.000 0.000 "::,..,.,,.., Pleue print or trie.~.Drorm.lfoD e R Docllment Title(s) (or transactions contain!#lihereU;}, (all areas applicable to your document.!!!!!!! be filled in) I. 'BE-Uti (A/srt w..M pf fyt~tWIL " ," , ," , /'4/ .. .' 3, .. .. ': . .. •. ' Reference Number(s) ofDocuni'ent{assign~d Ilt relelts¢: .. !i .' Additional ~.f-e.~ence #'s on page __ of d~~iiinent ,.9..~ //:J..lo..·~'6>6,7 .f"'"" Grantor(S) E~"'i\IY as name(s) appear on document."" , .. )'./ ........ : .. , ..... ,:. ./::: "',.,. I. C~A-f'!/ I'I-lLi A-C.4 Bf Mi?l{;."/ . ' ""':"'" , .. ,~.", .. .' "" .' . ,'. .' .... ···'··.f ., .' .. :: . 2. , .' Adc!JtionaJ,,;;'me.~"on p~ke __ of document, .:, ........••... " Gtant~s).Exactly as,.riamii{".).appear on document . ~ fJ,'" <"JiP&t~ {;,'pi-)j;j£.'j'o;j 1~! '1#6,'.-.,) <.1 lE,e1S u's . ~. ~ • . .. 2. ::. ~ .. , .. , .. ~ ...... .' "" .""\ ":, , .,' , . Additional names ,;" p.g~~oldocu;!wnt Legal deSCriPtiun~~~re~aki~ Leilot, 1>11< plat Or section, to'hj; range) {-L& T ~.:l..d. "'" .... 1;'\ Su.~1t:.. ",.' ••.. WNGit f7tJ () . fJ'EN#;< VoL I ! e4~ ..... ~~'.'. " . Additional legal is on page __ ;;f'(\ocU1l)<i~t.· . ., .' ..... '''''.,-' .' Assesso~s Property Tax ParcellAcco,mt NlIliibe.r: ..... :: 33 J.]ODbl:t ....•. ; ............ i .[J.Asses~.r,.Tax # not yet assigned .' .... The AuditorlRecorder will rely on the information pni~g,,4 oIl'iIlis .!brm ..... ·the.Staff.will riot r~.IId.Jhe document to verify the accuracy or completeness of iIle indexing infonruition.~rovided hiire;n; .,:. /... . ... ,. "I am signing below and paying an additional $50 recording r';' (8l!"proylded:1n Rt:W 36.1~:tllO a:ad. referred 10 as an emergency nonstandard document), because Ihis doe.ime~t do.,s liot D1e..t.·nlargID aild ..... formatting reqUi~l Furthermore, 1 hereby understand Ibat the recoril.ing· p.ocesS may-~oJ'er:.up or·· .. otherwise ObsC:Z' / J:zo f thZC original document as a resu~ti::::;:;::~~sting;~~ .. ".... .' .. '. Note to submitter: Do no!A!!18bove b()r pay additional SSO fee if the document meets margin/formatting req6irem.ints : ..... ::. /' .......... RELINQ1.JISHMENT OF EASEMENT .", !IT lI:m 010W ,o.s81lNGlrON ) hat .. -" .... :. ", My commission ""pire~ /i-(~·~/l.,' " ........ . ,." .::, .... . ,: IC1!WfQI~9~:; reet(S§r!:~Iat Deed of nedication :::::::::::::: :: From: To: Date: Subject: Carrie Olson Hopper, Joe; Paradise, Jayna 10/23/200811:13:15AM Teets Short Plat Deed of Dedication Joe, Thanks for letting me know about the hold up. As is my custom of working with both the applicant and their representives, I am also including a cc: to the owners for their information. There are no time limits other than the 2-year requirement to record the short plats, which will end on October 17, 2009, with a possible one-year extension after that. I will proceed with the review process because we should have comments back within a month or so. By then maybe the contractual issues will be resolved. If you need to contact me by phone my number is 425-430-7235. Carrie Sent: Thursday, October 23, 2008 9:46 AM Carrie, I apologize we haven't submitted the deed documents yet. We are having some contractual difficulties with Mr. Teets and have stopped work on his project for the time being. We still intend to submit when those issues are resolved, but it looks like it may be towards the end of the year before you see something from us. Let me know if there are any time restraints as to when you need to have those documents, and if so I will let Mr. Teets know the urgency of getting them submitted. Thanks, Joe. Joe Hopper jhopper@paceng.com -----Original Message----- From: Carrie Olson fmailto:COlson@ci.renton.wa.usl Sent: Thursday, October 23, 2008 9:36 AM To: Jayna Paradise; Joe Hopper Subject: Teets Short Plat Deed of Dedication-Second Request Hi Joe, Just thought I'd remind you that your project submittal dated September 15th is still on hold pending receipt of the deed documents. These documents don't have to be signed at this point since we are only reviewing them for legal content. Please see attachments below and return to my attention. Thanks, Carrie Sent: Thursday, September 18,200810:14 AM Joe, Here is the information we discussed this morning regarding the Teets Short Plat submittal. Please right click on Deed icon and use "open with" MS Office to open the DEED form and use Adobe to open the partially filled out REETA form. Also, see the instruction info attached. Please submit four copies of each document as soon as possible to be included with your requested final review submittal. I will place the review submittal on hold until I receive the deed documents. Also, I am sending comments from Sonja Fesser to Rodney Hansen for his review. If you have questions, please contact me at 425-430- 7235. Thanks, Carrie Olson cc: Teets, Denney & Robin '''I' , Return Address: City Clerk's Office City of Renton 1055 South Grady Way Renton, W A 98055 DEED OF DEDICATION Project File #: :::::: :: Property Tax Parcel Number: Street Intersection: Reference Number(s) of Documents assigned or released: Additional reference numbeJS are on page __ ' Grantor(s): Grantee(s): 1. I. City of Renton, a Municipal Corporation LEGAL DESCRIPTION: (Abbreviated or full legal must go here. Additional legal on page ) The Grantor. for and in consideration of mutual benefits conveys, quit claims, dedicates and donates to the Grantee(s) as named above. the above described real estate situated in the County of King, State of Washington. IN WITNESS WHEREOF, I have hereunto set my hand and seal the day and year as written below. Approved and Accepted Bv: Grantor(s): Grantee(s): City of Renton Mayor City Clerk INDIVIDUAL FORM OF STATE OF WASHINGTON ) SS ACKNOWLEDGMENT COUNTY OF KING ) I certify that [ know or have satisfactory evidence that Notary Seal must be within box signed this instrument and acknowledged it to be hislher/their free and voluntary act for the uses and purposes mentioned in the instrument. Notary Public in and for the State of Washington Notary (Print) My appointment expires: Dated: HformslxxxFRMI AGREEI FORlVl DEED .DOC\ CDR Page I FORM 04 OOOlfbh Page.iJ ,'-." , Exhibit A Legal Description HforrnslxxxFRM/AGREElFORM DEED.DOC\CoR Page 2 Project: WO# PID GRANTOR: Street: FORM 04 OOOllbh " . I I HfomlsJxxxFRM! AGREE! FORM DEED .DOC\ CDR Map Exhibit Page 3 FORM 04 OOOlfbh ., . Hfonns!;u;xFRM/AGREEIFORM DEED.DOC\CoR Page 4 FORM 04 OOOlfbh ::::: ::::::::::.:. ~venue REAL ESTATE EXCISE TAX AFFIDAVIT Tlis famis}ol).l" r£nip A..EAEE TYFE OR FRlNT OiAPTER 82.45 RON -OiAPrER 458-Q1A WAC wtuJ ~ bjca:ti9" THIS AFFIDAVITWIlL NOT EEACCEFTED UNLESSALLAREASON ALL PAGESAREFULLY COMPlETED o """ to.;f"" , (5'et:.:d<.« lat ~fCf 'rsll..dIons) , "If' , ~N~ .~ I~I M<ilirg Aro-a« ~I " OtyfSad.Zip ~,,,,,,,,"p ; 5n:l ell lYop:rly ta: wrr~ 10: 0 Sane as BuyErfQa"1le I'~'"~ ~'.", ,.,.",.",,...-li~ iIiiI9HI vau::(s) N= 0 Mi'lIi'll AI1t{9l 0 Otyl9ae'Zip 0 Fh:lne No. (Irdldr"{l cre o::dEt 0 lI&e ooa{9l«~: __________________________________________________________________ __ This jropa1y is IoatB:I In o 0JEdI 00x if!Jf)' cr IhelislEd lUcas a-e berg SE(lrEgaa:l fromalil"QfI" 1U1II. Lig<l as:riPkn of prop!Ity (if rmre ~ IslB:da:I, )IOU rrey aIatI a9l'pB'ge ihS 10 em p;:ge of the .ffidatit) II saw l..a1:J i...I9'! ea::e:~: g1g" ~ a:ttUaa ccd3& (See IJid d lat p;:g3 fa" il'l!'Crl.l:lia'6) IslhS ~ ~ fran p-q::e1y Q P'!"dl:PEr €4_~ RCN (ravcflt crg:nzalO1)7 YES NO o 0 ~.. YES NO Islhs~c&ig_Sedasfcrailcn:lper~,33RCWi' 0 0 IsltisP'"CJB1Yda:Bfiuja;;<lJTB"Ii.S:!{qsl~famrd 0 0 ~aJtL.raI,CTtirrtu~<n::lper~.34? Isltisp-qu1yrooiyjrg~valBi(J1<1>h8aicap_qu1y 0 0 ru~,26FON? If ~~OJ'1"lPe.teasirS1u::tEdb3oN. ff) NJT1CE 0f00NTl~ ~ l..AK) CRaAlENr IJE) NEWOMIIER(S): Too:rtirue tte CUT81c1e9g-a;cn asfae:t Iat! a damlc3im asCUTErt I.fe(q:sl ~ faTrl3lifqiaJtu"e, a tinta") Iem. yw nut aWl Q'I (31 baIoN. Tte ro.rty a:Ee!O" rru:i ItB1 dtamire if thEllcn:I tra"demooo1irus tJQ..SI1 fyWd will iOOcae bjsgirg b::Ioo. If V"elon::l rolO"g3" Q.Bifies cr '{OJ rol'd 'M.S'1 uc:cRin..e Ite daSgSiCll a daSfi!3ion, II 'MIl tererro.ulonj lh3~rg a: crtI~creI Q(es will te de <rd payaje b{ 1m !Dla-a 1I'a"ltercr ;;f tte time ct Sa (RCIN 84.33.'140 a: RON 64.34.100), Prialosgi~ (3) taON, )OJ mayCCl'iad yo.r kx:3 carty a!IefU fa: mae iltCll"l"lai01 Ths 1m::! 0 chs 0 cte; nj Q.Blfy fa o:rtirun:e. DERJTY A~ DATE (2) NOTICEOFCOMF'tIANCE(HISTQRI(JIRCIIERTy) NE'N ONNffi(S): Tocutin.e t'j.Eriai ...aIlBiOl csh:toic ~, fA!Jl (3) baIoN .If tte raN OMB"(s) d::Es rd wi!h tnxnrw, all ai:iticrel tax caaJcte:::I fU"Url to~ 84.31 RON, sui l:ede m::! payaje ~ Ite sOlO" atr.niEl'l)' aI. te time Ii ~e. (3) QWNER(S} SGNATURE PRINT NAME II Us all p:rs:ra ~quty (Ia"9tie <rd irt,rgtie) irclu:B;j lm;elll~ "'~ Ifdaimirg iIlecerp;i01, list WAC n.rnte'" ord rEftll"t fa atrrIj:tim WAC NIl (5edc:n'&tm:t iOl) ______________________ __ Rw3::rJ fa ecerp;i0l Type d Do.:ure1 ""'.-Q"ca; SelUrg Rica $, ____________________ __ ."""" -I"""J ,;-_______ __ EiurnpjOl Oamed (cJ:d.Jj) $; _______________ __ TaoG:tle Sellirg Rica $'-=========== ExeS) T<I'( : sae $_ L"" ,, _________ _ ·DElirq..u1 lnlEre:t Sti:te $'-=========== LccaI $_ ·DElirq.o1 f"EI'&ty """" 'sae Toomcgy Foo $ ________ _ 'Affid:Mt R"o::ee:Irg Fee $ ____________________ _ T~ Doo $ ________ __ AMINI MUM OF $10.00 ISDUE IN FEE(~ AND/OR TAX 's:e. INSfFUCTIONS I CERTIFY UND~ PENALTY OFPER,JJRYTHAT THE FOREGOING lSTRUEANDCQRRECT, Slgmre Ii Grarta a Grria', Agn; ____________________ _ ~(~~)-------------- ~&dtyr:jsgirg: ........ Grartea a Grart.'. AginI ________________________ __ ~(~~)---------------­ cae & city rI!igirg: Pwjl,lry: Pajuyisad<r:6 C felCJlf Wid! ispriSttle l:J,'ifTlJiSlTTler1ln the saecare::ticrel irltiUicn faal1\3Kil1ll.JT1 tmn rj not rrue1tB1 flveyan ab{ afirEinill iJTNl..rt fixoob(1he a:utd I'd m::reltm five'lhCllB'"d d:::ll<rs I!O.OO],({l), cr bt I:dh i!TVI~ ordfine{RCWgo,2'l.aaJ (len REV B4COO1a:(a) {Q5~8107} THIS S¥.CE -T~SJRERS USE OI'IILY CCUNTY T~3JFe "', · .:. A REETA fonn is required to be sent with the Deed of Dedication at the time of recording. Please fill out the Grantor portion of the attached document (1), include tax parcel numbers (3). brief legal description (4), sign (8), and return to me with the signed and notarized deed. Don't change or fill in anything else. The City will pay the fees. page1j ., .'. DATE: TO: FROM: SUBJECT: CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS MEMORANDUM October 19, 2007 Andrea Petzel Sonja J. Fesser Teets Short Plat, LUA-07-101-SHPL Format and Legal Description Review Bob Mac Onie and I have reviewed the above referenced short plat submittal and have the following comments: Comments for the Applicant: The dedication of land for street purposes on the short plat (the 5' strip adjoining Meadow Ave N) requires approval by the City Council. Said dedication is achieved via a recorded City of Renton Dedication Deed document. If the dedication is to be recorded with the short plat, the dedication process needs to be timed in such a way that Council approval and all other matters pertaining to the dedication have been addressed and resolved, and said document is ready to record. The Deed of Dedication document includes both a legal description exhibit and a map exhibit. The legal description exhibit should be prepared, stamped, dated and signed by the applicant's surveyor. The surveyor should also prepare the map exhibit. The first page of said document needs to include an abbreviated legal description. The dedication process requires an updated title report Plat Certificate document, dated within 45 days of Council action on said dedication. Talk to the Project Manager if there are questions or further information is needed. Note the bearings and dimensions of all sides of the two lots (on the short plat drawing). Information needed for final short plat approval includes the following: Note the City of Renton land use action number and land record number, LUA-07-l Ol-SHPL and LND-20-0499, respectively, on the drawing in the spaces already provided. The type size used for the land record number should be smaller than that used for the land use action number. \H:\Fiie SyslLND -Land Subdivision & Surveying Records\LND-20 -Short Plats\0499\RV070924.doc I!Carrie"'oison -RV070924 doc . . '. October 26, 2007 Page 2 Show two ties to the City of Renton Survey Control Network The geometry will be checked by the city when the ties have been provided. Note what was found when visiting the existing monuments. Provide short plat and lot closure calculations. The symbol for what has been, or is to be, set at the corners of the proposed lots, currently noted in the "LEGEND" block, is not shown on the short plat lots Note discrepancies between bearings and distances of record and those measured or calculated, if any. Note the relinquishment of all easements for access, light, view and air (to the State of Washington per Rec. No. 4695952) on the short plat submittal (Rainier Title Plat Certificate, Order No. 430628, dated August 8, 2007). If the private garage access easement (to be relinquished) is not released by the time this short plat is recorded, then retain said reference on the drawing (Rec. No. 9312102007). If said easement has been released, then remove said reference from the short plat submittal Note the plat name of the property to the south of the subject parcel (on the drawing). The ci ty addresses for the proposed lots are: Lot I is 3616 Meadow Ave N, and Lot 2 is 3610 Meadow Ave N. Note said addresses on the short plat drawing in the spaces already provided. On the final short plat submittal, remove all references to concrete, rackery, topog lines, trees, concrete slab, utilities facilities and other items not directly impacting the subdivision. These items are provided only for preliminary short plat approval. Remove the "CNIL ENGINEER', "SURVEYOR", "DEVELOPER" and "PROJECT DATA" blocks from the final submittal. Remove all references to zoning and density. It appears that Doris Pease is to be included in the one "ACKNOWLEDGMENT" block shown on the short plat drawing. If she does not sign with Mr. and Mrs. Teets, then another "ACKNOWLEDGMENT" block is needed. The "DECLARATION OF COVENANT" block should be removed from the short plat submittal, if there is no new private easement shared by both of the lots. Note that if there are easements, restrictive covenants or agreements to others (City of Renton, etc.) as part of this subdivision, they can be recorded concurrently with the short plat. The short plat drawing and the associated document(s) are to be given to the Project Manager as a package. The recording number(s) for the associated document(s) are to be referenced on the short plat H:\File Sys\LND -Land Subdivision & Surveying RecordsILND-20 -Short Plats\0499\RV070924.doc\cor .' October 26, 2007 Page 3 "-:::=:::-:---::::"=:: --":-: ' ":: ~- drawing. Provide spaces for the recording numbers thereof. Fee Review Comments: The Fee Review Sheet for this review of the preliminary short plat is provided for your use and infonnation. H:\File Sys\LND. Land Subdivision & Surveying RecordslLNO-20 -Short Plats\0499\RV070924.doc\cor }age31 ;. Return Address: iJA /, .;If'3? IV7 l;!V-t: Sf: MI/:&v'k( I !tilt t/ r 7dPrJ UEVElOP~"" ' CITY dt-', ' .. ! FEB 2 a 1.008 Please print or type informaUon WASHINGTON STATE RECORDER'S Cover Sheet (RCW 6504) 0 Document Title(s) (or transactions contained therein): (all areas applicable to your document must be filled in) L 'Be U'1 CA/srt vt.t&'f $f f~s£j/ue;-h, 3. 4, Reference Number(s) of Documents assigned or released: Additional reference #'s on page ___ of document 931 ;1../0 ;J, ()O7 Grantor(s) Exa\tly as name(s) appear on document L CInU.A--t /t1rhL yA-C4RfM£1L 2. , Additional names on page ___ of document. Gran tee( s) Exactly as name( s) appear on document L b€-AJA)EY T !Lite! /?J61/v ('\ 16eK MJ ~u' -5 T P&f~ 2. , Additional names on page of document. Legal description (abbreviated: i.e. lot, block, plat or section, townSj' range) {' fJ'EN::tf .;( L» T l')" d. ~ t \ \ ~ MNJS 1/<. W N G-Pr f1? r3 tV " VvL II 6l:~ (ptf- Additional legal is on page __ of document. Assess04s Property Tax Parcel/Account Number 33 J-]O()Ia'~ o Assessor Tax # not yet assigned The AuditorlRecorder will rely on the information provided on this form, The staff will not read the document to verify the accuracy or completeness of the indexing information provided hereil), "I am signing below and paying an additional $50 recording fee,(as provided in RCW 36.18.010 and referred to as an emergency nonstandard document), because this document does not meet margin and formatting requirements. Furtbermore, I hereby understand that the recording process may ~over up or otherwise obscW;a:of the ~ original document as a result of this request." (,Vf'J /-. . Signature of Requesting Pa rty Note to submitte .... : Do notA;fn above nor pay additional $50 fee if the document meets margin/formatting requirements . . , " RELINQUISHMENT OF EASEMENT For a VALUABLE CONSIDERATION ~t or \~b. is beteh)' a.:kM~. 1:00 Grallt""~) CAlli. A CARl'E.NlER and MlIry·I>. C"rpeme<,lmshftlld and wife, 4 Hereby grants and co""ey~ to D\lIlll}' !. Teets. Robin D. TeW and Doris!. Pease, their succe&6011l and assigns. a full and <:<lmplete release of the easement for Garage and Garage Access purposes over the southerly portion of the Grantee's property lI$ deicribed in Ea!lement reronled under King ('.ounty Recording Nutttber 9J 121fJ2007. IN WITN"ESS WHEREOF, THE GRANtOR HAS EXECUTED TIllS ~AY OF£-e.~ ,2mt U~ ~~/~C> '~D TV A 1'.""""", ACKNOWLEDGEMENT STATE OF WASHINGTON ) )!'$ Cooniy or K.\",~ }. I <ertiry tim! I know QT Imve oati.fac!ory evidence that Carl A. Carpenter and Mary A. Carpenter are the pel'SDns who appeared before me, and said persons acknowledged that they signed this instrument and ackoow1edgJ:: it In be thcir tree and volUlltary act fur the uses and purposes ::onedintw~ment ~' '2;1/ ""N"'ot"""ary""~"'.-,::so-. -7'L;~d::-- 4MtliA A. Tervt,:oe'1 Prim Notary's Name T lo.f ...... ____ ",",,; .. ;_ .. _.t .t'" ........ " ... co ........ From: To: Date: Subject: Carrie Olson Joe Hopper 12/10/2007 9:37:27 AM Teets Short Plat Joe, Here is the informtion we discussed this morning regarding the Teets Short Plat submittal. Please open the REETA form with Adobe to use a partialy filled out form. The deed will be reviewed along with the short plat drawings. Please submit four copies of each document and of the revised drawings to my attention. Thanks. Carrie Olson DATE: TO: FROM: SUBJECT: CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS MEMORANDUM October 19, 2007 Andrea Petzel Sonja J. Fesser Teets Short Plat, LUA-07-101-SHPL Format and Legal Description Review Dob Mac Onie and T have reviewed the above referenced short plat submittal and have the following comments: Comments for the Applicant: The dedication ofland for street purposes on the short plat (the 5' strip adjoining Meadow Ave N) requires approval by the City Council. Said dedication is achieved via a recorded City of Renton Dedication Deed document. If the dedication is to be recorded with the short plat, the dedication process needs to be timed in such a way that Council approval and all other matters pertaining to the dedication have been addressed and resolved, and said document is ready to record. The Deed of Dedication document includes both a legal description exhibit and a map exhibit. The legal description exhibit should be prepared, stamped, dated and signed by the applicant's surveyor. The surveyor should also prepare the map exhibit. The first page of said document needs to include an abbreviated legal description. The dedication process requires an updated title report Plat Certificate document, dated within 45 days of Council action on said dedication. Talk to the Project Manager ifthere are questions or further information is needed. Note the bearings and dimensions of all sides of the two lots (on the short plat drawing). Information needed for final short plat approval includes the following: Note the City of Renton land use action number and land record number, LUA-07-101-SHPL and LND-20-0499, respectively, on the drawing in the spaces already provided. The type size used for the land record number should be smaller than that used for the land use action number. IC,IDOClJME-! ICOlsonV.oCALS-! ITemplgwpnntlRV070924.doc December 10, 2007 Page 2 Show two ties to the City of Renton Survey Control Network. The geometry will be checked by the city when the ties have been provided. Note what was found when visiting the existing monuments. Provide short plat and lot closure calculations. The symbol for what has been, or is to be, set at the corners of the proposed lots, currently noted in the "LEGEND" block, is not shown on the short plat lots Note discrepancies between bearings and distances of record and those measured or calculated, if any. Note the relinquishment of all easements for access, light, view and air (to the State of Washington per Rec. No. 4695952) on the short plat submittal (Rainier Title Plat Certificate, Order No. 430628, dated August 8, 2007). If the private garage access easement (to be relinquished) is not released by the time this short plat is recorded, then retain said reference on the drawing (Rec. No. 9312102007). If said easement has been released, then remove said reference from the short plat submittal Note the plat name of the property to the south ofthe subject parcel (on the drawing). The city addresses for the proposed lots are: Lot 1 is 3616 Meadow Ave N, and Lot 2 is 3610 Meadow Ave N. Note said addresses on the short plat drawing in the spaces already provided. On the final short plat submittal, remove all references to concrete, rockery, topog lines, trees, concrete slab, utilities facilities and other items not directly impacting the subdivision. These items are provided only for preliminary short plat approval. Remove the "CIVIL ENGINEER', "SURVEYOR", "DEVELOPER" and "PROJECT DATA" blocks from the final submittal. Remove all references to zoning and density. It appears that Doris Pease is to be included in the one "ACKNOWLEDGMENT" block shown on the short plat drawing. If she does not sign with Mr. and Mrs. Teets, then another "ACKNOWLEDGMENT" block is needed. The "DEC LARA nON OF COVENANT" block should be removed from the short plat submittal, ifthere is no new private easement shared by both of the lots. Note that if there are easements, restrictive covenants or agreements to others (City of Renton, etc.) as part of this subdivision, they can be recorded concurrently with the short plat. The short plat drawing and the associated document(s) are to be given to the Project Manager as a package. The recording number(s) for the associated document(s) are to be referenced on the short plat drawing. Provide spaces for the recording numbers thereof. C:\DOCUME-J \COlson\LOCALS~ I \Tcmp\gwprint\RV070924.doc\msoffice December 10, 2007 Page 3 Fee Review Comments: The Fee Review Sheet for this review of the preliminary short plat is provided for your use and information. C:\DOCUME-l\COlson\LOCALS-l\Temp\gwprint\RV070924,doc\msoftice Return Address: City Clerk's Office City of Renton 1055 South Grady Way Renton, WA 98055 DEED OF DEDICATION Project File #: Property Tax Parcel Number: Street Intersection: Reference Number(s) of Documents assigned or released: Additional reference numbers are on page __ . Grantor(s): Grantee(s): 1. 1. City of Renton, a Municipal Corporation LEGAL DESCRIPTION: (Abbreviated orfuillegal must go here. Additional legal on page ) The Grantor, for and in consideration of mutual benefits conveys, quit claims, dedicates and donates to the Grantee(s) as named above, the above described real estate situated in the County of King, State of Washington. IN WITNESS WHEREOF, I have hereunto set my hand and seal the day and year as written below. Approved and Accepted Bv: Grantor(s): Grantee( s): City of Renton Mayor City Clerk lNDIVlDUAL FORM OF STATE OF WASHINGTON ) SS ACKNOWLEDGMENT COUNTY OF KING ) [ certify that I know or have satisfactory evidence that Notary Seal must be within box signed this instrument and acknowledged it to be his/her/their free and voluntary act for the uses and purposes mentioned in the instrument. Notary Public in and for the State of Washington Notary (Print) My appointment expires: Dated: Hforms/xxxFRM/AGREE/FORM DEED.DOCI MSOffice Page I FORM 04 OOOllbh Exhibit A Legal Description Hfonns/xxxFRM/AGREEIFORM DEED.DOCI MSOffice Page 2 Project: IVO# PID GRANTOR: Street: FORM 04 OOOllbh Map Exhibit HfonnslxxxFRMIAGREEIFORM DEED.DOCI MSOffice Page 3 FORM 04 000 I ihh PLEASE TYPE OR PRINT REAL ESTATE EXCISE TAX AFFIDAVIT CHAPTER 82.45 RCW -CHAPTER 45S-61 WAC This lo!'1ll is yOUT n:~Tlpt whcli st:lIl1pcd by cashin FOR t:SE ATCOliKTYT RF."~lJRER·S OFFICE (Use rOITn No. 84-0001 [I for Reponing Transfers of Controlling Interest ofEnlity UWllclsllip tLl th~ D~p~rtment ofRcl'cnue) nils AFFIDAVIT WILL NOT BE ACCEPTED CNLESS ALL AREAS 1-7 ARE FULI.V COMPLETE!) Kame Name City of Renton, a Municipal Corporation g! ~. Street Street 1055 South Grady Way City/Statcfl.ip City/State/Zip Renton Wa (8055 ADDRESS TO SEND ALL PROPERTY TAX RELATED CORRESPONDENCE': ALL TAX PARCEL NUMBERS COUNTY ASSESSED \' ALUE JF TAX EXEMPT 1\'ame Portion of tax ~arcel #(5] Street (same as Grantor information) II LEGAL DESCRIPTION OF PROPERTI' SITUATED IN D UNINCORPORATED _______ .COUNlY al OR rN CITY OF Renton Street Address (if property is improved): ________________________________________ _ Is tllis property currenlly: Classified or designated as forest land'! Chapter 84.33 RCW YES NO Classified as currenluse land (open space, faml n _ and agricultural, or timber)'! Chapter 84.34 RCW Exempt from property tax as a nonprofit IEil IiiIl organization'! Chapter 84.36 RCW ScHer'S Exempt Reg. No. Receiving special valuation as 'historic property? Chapter 84.26 RCW Property Type: _land only D land with previously used building o timber only Principal Use: o Apt. (4+ unit) o timber 0 agricultural D other o land with new building D laTld with mobile home o buildiTl,g only o residential [J commercial/industrial I (I) NOTICE OF CONTINUANCE CReW 8433 OR RCW 84.34) new owncr(s) of land that is classifieu or des1b'llated as current use or forest land wish to continue the classification or designation of such land, the new owner(s) must sign below. If the uew owner(s) do not desire to continue such classification or desib'llation, all compensating or additional tax calculated pursuant to RCW 84.33.120 and 140 or RCW 84.34.108 shall be due and payable by the seller or transferor at the time of sale. TIle county assessor must detennine if the land transferred qualifies to continue classification or designation and must so indicate below. Sib'llatures do not necessarily mean the land will remain in classification or designation. If it no longer qualifies, it will be removeu and the compensating taxes will be applied. All new owners must sib'll. This land o does 0 docs \lot qualify for continuance. Date ______ _ DEPU'IY ASSESSOR (2) NOTICE OF COMPLIANCE (Chapter 84.26 RCW) If the new owner(s) of property with special valuation as historic property wish to contiuue this special valuation the new owner(s) must sign below. If the new OWIIer(S) do not desire to continue sHch special valuation, all additional tax calculated pursuant to Chapter 84.26 RCW. shall be dlle and payable by the seller or transferor at the tlme of sale. (J) OWNER(S)SIGNATURE _ Description of personal property included in gross selling price. both ~ tangible (eg; furniture, equipment. elc.) or 11itall!;lhle (eg; goodWIlL agreem~nt not to compete, etc.) If exemption claimed, list WAC number and explanation. WAC No. (Sec/Sub) .....;4.;.5.;.8-6.:;.;.1:..;A,,-2:..:0..:5 __________ _ Explanation Transfer to government for public purposes Type of Document Deed of Dedication Date of Document ___________________ _ Gross Selling Price Personal Property (deduct) Taxable Selling Price 0.00 Elc:ciseTax: Slatc $. _____________ _ l.ocal $. ____________ _ Delinquent Interest: State $. _____________ _ Local $. ____________ _ Delinquent Penalty $.------------0-:,.,- Total Due $. __________ "0,,.0"'-0 • A MINIMUM OF $2.00 IS DU~;~~::~~E"INU FEE AND TAX. I Certify Under Penalty of Perjury Under TIle Laws of Tile State (] f Washington That The Foregoing Is Tmc And Correct. (See bnck (Jrthis fonn). Sib'llanlre of GrantorlAg~nt __________________________________________ _ Name (print} ______________________ _ Date and Place of Sih'lling: _________________ _ Signature of Grantee/Agent -,-:-,-:_,-:--,-:,-:-_______________ _ Name (print) _~K.;.a~t~h~y~K.;.e~o~l~k~e~r.~M=a~yo~r'-_________ _ Date & Place ofSib'lling: Renton Perjury: Perjury is a class C felony which is punishable by imprisonment in the state correctional institution for ~ maximum tenn of 110t more than five years, or by a fine in an amollnt fixed by the court of not more than five thousalld dollars ($5.000,00). or by botll imprisonment and fine (RCW 9A.20.020 (Iq). REV 84 OOOla (3-18-99) (PD 4-05-00) FOR TREASURER'S USE ONLY [JCOUNTY TREASURER [JDFPT. OF REVENUE [jCOUNTY ASSESSOR ljTAXPAYER A REETA fonn is required to be sent with the Deed of Dedication at the time of recording. Please fill out the Grantor portion of the attached document (1), include tax parcel numbers (3), brief legal description (4), sign (7), and return to me with the signed deed. TEETS: )RT PLAT CONDITIONS OF LUA 07-101 Project Condition Source of Condition The applicant shall obtain a demolition Administrator pennit and all required inspections completed for the removal of the existing house and garage prior to the recording of the short plat. In order to preserve and protect the one Administrator significant tree during utility and building constmction the tree shall be fenced off around the drip line and a sign posted that the tree is to be preserved, and the location of the tree shall be indicated on all utility construction plan sheets. The fencing shall be in place prior to the issuance of any utility construction pennits and shall remain until the final inspection of the new house on Lot 2 is complete. The applicant shall submit a revised, Administrator detailed landscape plan indicating the required street trees. The plan is subject to the review and approval of the Development Services project manager and is required prior to the issuance of the building permits. The applicant shall pay the required Administrator Transportation Mitigation Fcc based on $75.00 per net average daily trip. The garage access easement (Rec. Administrator #9312102007) shall be relinquished prior to recording the short plat. The applicant shall adhere to the Administrator recommendations of the geotechnical report from Geotech Consultants, Inc. (dated July 27, 2007), The applicant shall pay a $488,00 Fire Administrator Mitigation Fec prior to the recording of the short plat The project shall be required to comply Administrator with the Department ofFcology's Erosion and Sediment Control Requirements as outlined in Volume II ofthe 2001 edition of the Stonnwater Management ManuaL cc: City of Renton File LUA 07-101 Craig Burnell Jan lIlian Rocale Timmons "'hen Compliance is Required Prior to recording Prior to utility permits Prior to building pennits Prior to recording Prior to recording Throughout Prior to Recording Throughout 'ROYAL Party l'i otes Responsible Applicant Applicant Applicant Applicant Applicant Applicant Applicant Applicant " . ~=~JPACIFIC L-,\JGINEERING DEw,GN, LLC: CIVIL ENGINEERING AND PLANNING CONSULTANTS November 28, 2007 Ms. Andrea Petzel City of Renton Development Services 1055 South Grady Way Renton, W A 98055 RE: Teets Short Plat LUA 07-101, SHPL-A Dear Andrea: PED Job No.: 06089 We have revised the Short Plat drawings for the project referenced above in accordance with the Short Plat Decision dated October 17,2007. Enclosed for your review, are four copies of the revised plans. The following outline provides each of the Plat Decision Conditions exactly as written, along with a narrative response describing how each comment has been addressed: Short Plat Decision: The Teets Short Plat, File No. LUA 07-101, SHPL-A, is approved subject to the following conditions: 1. The applicant shall obtain a demolition permit and all required inspections completed for the removal of the existing house and garage prior to the recording of the short plat. Response: A demolition permit will be obtained prior to the removal of the existing structures on site. 2. 1n order to preserve and protect the one significant tree during utility and building construction the tree shall be fenced off around the drip line and a sign posted that the tree is to be preserved, and the location of the tree shall be indicated on all utility construction plan sheets. The fencing shall be in place prior to the issuance of any utility construction permits and shall remain until the final inspection of the new house on Lot 2 is complete. Response: Tree preservation fencing will be installed and maintained around the significant tree throughout construction until the final inspection ofthe Lot 2 building is complete. wwvv.paceng.com 15445 53RD AVENUE SOUTH, SUITE 1 00, SEATTLE, WA 98188 FAX 206388-1648 PHONE 425251-8811 206431-7970 .,. . Ms. Andrea Petzel City of Renton November 28, 2007 PED #06089 3. The applicant shall submit a revised, detailed landscape plan indicating the required street trees. The plan is subject to the review and approval of the Development Services project manager and is required prior to the issuance of the building permits. Response: The revised landscape plan is included with this suhmittal. 4. The applicant shall pay the required Transportation Mitigation Fee based on $75.00 per net average daily trip prior to the recording of the short plat. Response: The developer will pay the required Transportation Mitigation Fee as noted above. 5. The garage access easement (Rec. #9312102007) shall be relinquished prior to recording the short plat. Response: The garage access easement relinquishment is in the process of being signed and recorded. 6. The applicant shall adhere to the recommendations of the geotechnical report from Geotech Consultants, Inc. (dated July 27, 2007). Response: The developer will adhere to the recommendations of the geotechnical report. 7. The applicant shall pay a $488.00 Fire Mitigation Fee prior to the recording of the short plat. Response: The developer will pay the required Fire Mitigation Fee as noted above. 8. The project shall be required to comply with the Department of Ecology's Erosion and Sediment Control Requirements as outlined in Volume !I of the 2001 edition of the Stormwater Management Manual. Response: The developer will comply with the DOE Erosion Control requirements a noted above. Pacific Engineering Design, LLC Page 2 of3 R:106089 Teets Short Piatl08069 Pial Decision Response Letler.doc ,. Ms. Andrea Petzel City of Renton November 28. 2007 PED #06089 I believe that the above responses, together with the enclosed revised plans address all conditions of approval. If you have questions, comments. or need additional information, please contact me at your convenience. Thank you. Sincerely, ,Ju-')1)7r!;/7' ) ,j.<iseph M. Hopper, PE Enc: Revised Landscape Plan cc: Mr. Darcey Teets Mr. Denney Teets Pacific Engineering Design. LLC R:1060S9 Teets Short PiatlOS069 Plat Decision Response Letter.doc Page 3 of3 .' :PACIFIC t:NGINEERING DESIGN, po -- CIVIL ENGINEERING AND PLANNING CONSULTANTS November 28,2007 Ms. Andrea Petzel City of Renton Development Services 1055 South Grady Way Renton, WA 98055 RE: Teets Short Plat LUA 07-101, SHPL-A Dear Andrea: PED Job No.: 06089 We have revised the Short Plat drawings for the project referenced above in accordance with the Short Plat Decision dated October 17,2007. Enclosed for your review, are four copies of the revised plans. The following outline provides each of the Plat Decision Conditions exactly as written, along with a narrative response describing how each comment has been addressed: Short Plat Decision: The Teets Short Plat, File No. LVA 07-101, SHPL-A, is approved subject to the following conditions: I. The applicant shall obtain a demolition permit and all required inspections completed for the removal of the existing house and garage prior to the recording of the short plat. Response: A demolition permit will be obtained prior to the removal of the existing structnres on site. 2, In order to preserve and protect the one significant tree during utility and building construction the tree shall be fenced oif around the drip line and a sign posted that the tree is to be preserved, and the location of the tree shall be indicated on all utility construction plan sheets. The fencing shall be in place prior to the issuance of any utility construction permits and shall remain until the final inspection of the new house on Lot 2 is complete, Response: Tree preservation fencing will be installed and maintained around the significant tree throughout construction until the final inspection of the Lot 2 building is complete. www.paceng.com 15445 53RD AVENUE SOUTH, 8UITE100,SEATTLE. WA 98188 FAX20638B-1648 PHONE 425 251-8811 206431-7876 Ms, Andrea Petzel City of Renton November 28, 2007 PED #06089 3, The applicant shall submit a revised, detailed landscape plan indicating the required street trees, The plan is subject to the review and approval of the Development Services project manager and is required prior to the issuance of the building permits, Response: The revised landscape plan is included with this submittal. 4, The applicant shall pay the required Transportation Mitigation Fee based on $ 75,00 per net average daily trip prior to the recording of the short plat, Response: The developer will pay the required Transportation Mitigation Fee as noted above. 5, The garage access easement (Rec, #9312102007) shall be relinquished prior to recording the short plat, Response: The garage access easement relinquishment is in the process of being signed and recorded. 6, The applicant shall adhere to the recommendations of the geotechnical report from Geotech Consultants, Inc, (dated July 27, 2007), Response: The developer will adhere to the recommendations of the geotechnical report. 7, The applicant shall pay a $488,00 Fire Mitigation Fee prior to the recording of the short plat, Response: The developer will pay the required Fire Mitigation Fee as noted above. 8. The project shall be required to comply with the Department of Ecology's Erosion and Sediment Control Requirements as outlined in Volume II o[the 2001 edition of/he Stormwater Management Manual, Response: The developer will comply with the DOE Erosion Control requirements a noted above. Pacific Engineering Design. LLC Page 2 of3 R: 106089 Teels Shari Pial108069 Pial Decision Response Letter,doc r Ms. Andrea Petzel City of Reman November 28, 2007 PED #06089 I believe that the above responses, together with the enclosed revised plans address all conditions of approval. If you have questions, comments, or need additional information, please contact me at your convenience. Thank you. Enc: Revised Landscape Plan cc: Mr. Darcey Teets Mr. Denney Teets Pacific Engineering Design. LLC R: 106089 Teets Short PiatlO8069 Plat Decision Response Letter.doc Page 3 0[3 CITY OF RENTON PLANNING / BUILDING / PUBLIC WORKS MEMORANDUM Date: November 2, 2007 To: City Clerk's Office From: Stacy Tucker Subject: Land Use File Closeout Please complete the following information to facilitate project closeout and indexing by the City Clerk's Office. Project Name: LUA (file) Number: Cross-References: AKA's: Project Manager: Acceptance Date: Applicant: Owner: Contact: PID Number: ERC Decision Date: ERC Appeal Date: Administrative Approval: Appeal Period Ends: Public Hearing Date: Date Appealed to HEX: By Whom: HEX Decision: Date Appealed to Council: By Whom: Council Decision: Mylar Recording Number: Teets Short Plat LUA-07-101, SHPL-A Andrea Petzel September 21, 2007 Darcey Teets Denney & Robin Teets; Doris J. Pease Joe Hopper, P.E. -Pacific Engineering Design, LLC 3342700617 October 17, 2007 October 31, 2007 Date: Date: Project Description: Application for administrative short plat approval for a 2-lot subdivision in the R-8 zone. Density would be 7.5 dwelling units/acre. The existing home would be demolished. Proposed lot sizes would be 5,880 sq. ft. and 5,733 sq. ft. Both new lots would have direct access to Meadow Ave. N via private driveways. There are two significant trees onsite, and no critical areas are present. Location: 3612 Meadow Avenue N Comments: PARTIES OF RECORD TEETS SHORT PLAT LUA07-101, SHPL-A Joe Hopper, P.E. Pacific Engineering Design, LLC 15445 53rd Avenue S ste: #100 Seattle, WA 98188 tel: (206) 431-7970 eml: jhopper@paceng.com (contact) Darcey Teets 2838 109th Avenue SE Bellevue, WA 98004 tel: (206) 391-1500 (applicant) Updated: 09/21/07 Denney & Robin Teats 3 S Hollow Road Dix Hills, NY 11746 tel: (601) 667-9276 (owner) Doris J. Pease 16205 SE 9th Street Bellevue, WA 98008 tel: (425) 503-7444 (owner) (Page 1 of 1) November 2, 2007 Joe Hopper, P.E. Pacific Engineering Design, LLC 15445 5yd Avenue S #100 Seattle, W A 98188 SUBJECT: Teets Short Plat LUA07-101, SHPL-A Dear Mr. Hopper: CIT1 :lFRENTON Planning/BuildinglPublic Works Department Gregg Zimmerman P.E., Administrator This letter is to inform you that the appeal period ended on October 31, 2007 for the Administrative Short Plat approval. No appeals were filed. This decision is final and you may proceed with the next step of the short plat process. The enclosed handout, titled "Short Plat Recording," provides detailed information for this process. The advisory notes and conditions listed in the City of Renton Report & Decision dated October 17, 2007 must be satisfied before the short plat can be recorded. If you have any questions regarding the report and decision issued for this short plat proposal, please call me at (425) 430- 7270. For questions regarding the recording process for the short plat, as well as for submitting revised plans, you may contact Carrie Olson at (425) 430-7235. Sincerely, f2k~t4( Andrea Petzel ASSOCiate Planner Enclosure(s) cc: Denney & Robin Teets, Doris Pease I Owners Darcey Teets / Applicant ------------1-O-55-S~~-uili--G-rn-d-y-W-a-y---Re-n-to-n-,W--M-hm-g-ID-n--98-0-57-------------~ 6iC) This paper contains 50% recycled material, 30%post consumer" AHEAD OF THE CURVE CITY (' RENTON Planning/Building/Public Works Department Gregg Zimmerman P.E., Administrator October 29, 2007 Joe Hopper, P.E. Pacific Engineering Design, LLC 15445 53'd Avenue S #100 Seattle, W A 98188 Subject: Comments from Property Services -Teets Short Plat City of Renton File LUA 07-101, SHPL-A Dear Mr. Hopper: As per the notation in the Report and Decision dated October 16,2007, enclosed are the comments from the City's Property Services Department. These comments will guide you in the preparation of the short plat for recording. If you have any questions feel free to contact me at (425) 430-7270. /.&incere1y , / I I /-. ' .. i rj./.0 ;' j , ./ . /':, ,:.1 /.j--~) L L{:,-/~.,(\(~,c.v;:~' Andrea Petzel, Planrler Development Services Division Enclosure cc: City of Renton File LUA07-101 ------l-O-SS-S-o-uth-. -G-lad-y-W-a-y--R-e-n-to-n,-w-as-hin-gto~n-98~O-57------~ * This paper contains 50% recycled material, 30% postconsume~ AHEAD OF THE CURVE .~ DATE: TO: FROM: SUBJECT: CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS MEMORANDUM October 19, 2007 Andrea Petzel Sonja J. Fesser ~ Teets Short Plat, LUA-07-101-SHPL Format and Legal Description Review Bob Mac Onie and I have reviewed the above referenced short plat submittal and have the following comments: Comments for the Applicant: The dedication of land for street purposes on the short plat (the 5' strip adjoining Meadow Ave N) requires approval by the City CounciL Said dedication is achieved via a recorded City of Renton Dedication Deed document If the dedication is to be recorded with the short plat, the dedication process needs to be timed in such a way that Council approval and all other matters pertaining to the dedication have been addressed and resol ved, and said document is ready to record. The Deed of Dedication document includes both a legal description exhibit and a map exhibit The legal description exhibit should be prepared, stamped, dated and signed by the applicant's surveyor. The surveyor should also prepare the map exhibit The first page of said document needs to include an abbreviated legal description. The dedication process requires an updated title report Plat Certificate document, dated within 45 days of Council action on said dedication. Talk to the Project Manager if there are questions or further information is needed. Note the bearings and dimensions of all sides of the two lots (on the short plat drawing). Information needed for final short plat approval includes the following: Note the City of Renton land use action number and land record number, LUA-07-101-SHPL and LND-20-0499, respectively, on the drawing in the spaces already provided. The type size used for the land record number should be smaller than that used for the land use action number. \H:\File Sys.\LND -Land Subdivision & Surveying Records.\LND-20 -Short Plats\0499\RV070924.doc October 26, 2007 Page 2 Show two ties to the City of Renton Survey Control Network. The geometry will be checked by the city when the ties have been provided. Note what was found when visiting the existing monuments. Provide short plat and lot closure calculations. The symbol for what has been, or is to be, set at the comers of the proposed lots, currently noted in the "LEGEND" block, is not shown on the short plat lots Note discrepancies between bearings and distances of record and those measured or calculated, if any. Note the relinquishment of all easements for access, light, view and air (to the State of Washington per Rec. No. 4695952) on the short plat submittal (Rainier Title Plat Certificate, Order No. 430628, dated August 8, 2007). If the private garage access easement (to be relinquished) is not released by the time this short plat is recorded, then retain said reference on the drawing (Rec. No. 9312102007). If said easement has been released, then remove said reference from the short plat submittal Note the plat name of the property to the south of the subject parcel (on the drawing). The city addresses for the proposed lots are: Lot 1 is 3616 Meadow Ave N, and Lot 2 is 3610 Meadow Ave N. Note said addresses on the short plat drawing in the spaces already provided. On the final short plat submittal, remove all references to concrete, rockery, topog lines, trees, concrete slab, utilities facilities and other items not directly impacting the subdivision. These items are provided only for preliminary short plat approval. Remove the "CIVIL ENGINEER', "SURVEYOR", "DEVELOPER" and "PROJECT DATA" blocks from the final submittal. Remove all references to zoning and density. It appears that Doris Pease is to be included in the one "ACKNOWLEDGMENT" block shown on the short plat drawing. If she does not sign with Mr. and Mrs. Teets, then another "ACKNOWLEDGMENT" block is needed. The "DECLARATION OF COVENANT" block should be removed from the short plat submittal, if there is no new private easement shared by both of the lots. Note that if there are easements, restrictive covenants or agreements to others (City of Renton, etc.) as part of this subdivision, they can be recorded concurrently with the short plat. The short plat drawing and the associated document(s) are to be given to the Project Manager as a package. The recording number(s) for the associated document(s) are to be referenced on the short plat drawing. Provide spaces for the recording numbers thereof. H:\File Sys\LND -L'lnd Subdivision & Surveying Reeords\LND-20 -Short Plats\0499\RV070924.doe\cor October 26, 2007 Page 3 Fee Review Comments: The Fee Review Sheet for this review of the preliminary short plat is provided for your use and information. H:\File Sys\LND -land Subdivision & Surveying Records\LND-20 -Short Plats\0499\RV070924.doc\cor PROPERTY SER lS FEE REVIEW FOR SUBDIVISIONS 007 --4L_ ~_~ RECEIVED FROM ___ ~ __ ~ ___ ~ __ (datc) JOB ADDRESS: i'!Ic;.l:2: .W!=:ATXl'NA'Ie; W. ___ ______ n _ WO# i1eoe NATURE OF WORK: 2~~ :")I-!ol=rf PI ~( I bel B I'II-IOBT -P.J.&r.J.n_ LND # ;>0 -0499 _____ _ X PRELIMINARY REVIEW OF SUBDIVISION Y LONG PLAT, NEED MORE INFORMATION: --LEGAL DESCRIPTION SHORT PLAT, BINDING SITE PLAN, ETC. PID #'s VICINrry MAP FINAL REVIEW OF SUBDIVISION, THIS REVIEW REPLACES SQUARE FOOTAGE OTHER PRELIMINARY FEE REVIEW DATED FRONT FOOTAGE SUBJECT PROPERTY PARENT PID#..3a.4e'10 '"-CG17 X NEW KING CO. TAX ACCT.#(s) are required when assigned by King County. It is the intent of this development fee analYSIS to put the developer/owner on notice, that the fees quoted below may be applicable to the subject site upon development of the property. All quoted fees are potential charges that may be due and payable at the time the constmction permit is issued to install the on-site and off-site improvements (i.e. underground utilities, street improvements, etc.) Triggering mechanisms for the SOC fees will be based on current City ordinances and determineJ by the applicable Utility Section. Please note flIat flIese fees are subject to change wilhout notice. Final fees will be based on rates in effect at time of Building Permit/Construction Permit application. The existing house on SP Lot # ___ , addressed as has not previously paid ~~_~ SDC fees, due to connection to City utilities prior to existance of SDC fee Ord. SP Lot#" \vill be subject to futnre SDC fees if triggering mechanisms are touched within current City Ordinances. We understand that this subdivision is in the preliminary stage and that we will have the opportunity to review it again before recordation. The followin~ quoted fees do NOT include inspection fees, side sewer permits, r/wpermit fees or the cost of water meters. SPECIAL ASSESSMENT DISTRICT PARCEL METHOD OF ASSESSMENT ASSESSMENT DISTRICTS NO. NO. ASSESSMENT UNITS Latecomer A~reement (pvt) WATER Latecomer A~reement (pvt) W ASTEW ATER Latecomer A~reement (pvt) OTHER Special Assessment District/WATER Special Assessment District/WASTEWATER Joint Use Agreement (METRO) Local Improvement District Traffic Benefit Zones $75.00 PER TRIP, CALCULATED BY TRANSPORTATION FUTURE OBLIGATIONS SYSTEM DEVELOPMENT CHARGE -WATER .. Estimated .. Pd Prevo --Partially Pd (Ltd Exemption) .. Never Pd Single familv residential $1,956/unit x Mobile home dwelling unit $1,956/unit in park Apartment, Condo $1,I74/unit not in CD or COR zones x Commercial/Industrial, $0.273/sq. ft. of property (not less than $1,956.00) x Boeing, by Special Agreement/Footprint of Bldg plus 15 ft perimeter (2,800 GPM threshold) SYSTEM DEVELOPMENT CHARGE ~ W ASTEW A TER -. Estimated .. Pd Prev. .. Partiallv Pd (Ltd Exemption) .. Never Pd Sin~le familY residential $1,017/unit x Mobile home dwelline: unit $1,0I7/unit x Apartment, Condo $610/unit not in CD or COR zones x Commercial/Industrial $0.142/sq. ft. of property x(not less !han $1,017.00) SYSTEM DEVELOPMENT CHARGE -SURF ACEW ATER .. Estimated .. Pd Prevo .. Partiallv Pd (Ltd Exem---.ption) .. Never Pd Sinele famiIv residential and mobile home dwelling unit $759/unit x AU other properties $0.265/sq rt of new impervious area of property x (not less than $759.00) # OF UNITS/ SQ. FfG. ~ I PRELIMINARY TOTAL ~/IrnJ~ }#tr . (~f(IDCJr ) 9/~Or $ OR FEE -0- -0 -0- /-0- / /-0 • SDCFEE ~ IOI /.<"ln 'jj '" 0 • 0 " -.J , " Signatu~'()Rev· illg Authonty DiE .. *If subject property is within an LID, it is developers responsibility to check with the Finance Dept. for paid/un-paid status. ~ 0 < e-o • Square footage figures are taken from the King County Assessor's map and are subject to change. " 0 Current City SDC fee charges apply to ___________________ _ EFFECTIVE January 2, 2006 City of Renton Department of Planning! Building! Public Works ENVIRONMENTAL & DEVELOPMENT APPLICATION REVIEW SHEET REVIEWING DEPARTMENT: B·A .. L; S\/(s COMMENTS DUE: OCTOBER 5, 2007 APPLICATION NO: LUA07-101, SHPL-A J DATE CIRCULATED: SEPTEMBER 21, 2007 APPLICANT: Darcey Teets PROJECT MANAGER: Andrea Petzel PROJECT TITLE: Teets Short Plat PLAN REVIEW: Jan lilian SITE AREA: 12,151 square feet BUILDING AREA (gross): N/A LOCATION: 3612 Meadow Avenue N WORK ORDER NO: 77808 SUMMARY OF PROPOSAL: Application for administrative short plat approval for a 2-lot subdivision in the R-8 zone. Density would be 7,5 dwelling units/acre. The existing home would be demolished. Proposed lot sizes would be 5,880 sq, ft. and 5,733 sq. ft. Both new lots would have direct access to Meadow Ave. N via private driveways. There are two significant trees onsite, and no critical areas are present. A. ENVIRONMENTAL IMPACT (e,g, Non-Code) COMMENTS Element of the Probable Probable More Element of the Probable Probable More Environment Minor Major Information Environment Minor Major Information Impacts Impacts Necessary Impacts Impacts Necessary Earth Housinq Air Aesthetics Water Liqht/G/are Plants Recreation Land/Shorelme Use Utilities Animals Transportation Environmental Health Public Services Energy! Historic/Cultural Natural Resources Preservation Airport Environment 10.000 Feet 14.000 Feet B. POLICY-RELATED COMMENTS C, CODE-RELA TED COMMENTS We have reviewed this application with particular attention to those areas in which we have expertise and have identified areas of probable impact or areas where additional information is needed to properly assess this proposal. Signature of Director or Authorized Representative Date REPORT & DECISION A. REPORT DA TE. Project Name: Applicant/ Contact: File Number: Project Description: Project Location: Project Location Map City of Renton Department of Planning / Building / Public Works ADMINISTRATIVE SHORT PLAT SUMMARY AND PURPOSE OF REQUEST: Oelober 17, 2007 Teets Short Plat Applicant: Darcey Teets 2838 109'h Avenue SE Bellevue, W A 98004 LUA 07-101, SHPL-A Contact: Joe Hopper, P.E. Pacific En.,gineering Design, LLC 1544553' Avenue, S. SUIte lOa Seattle, W A 98188 Project Manager: Andrea Petzel, Planner Application for administrative short plat approval for a 2-1o! subdivision in the R-8 zone. Density would be 7.4 dwelling units/acre. The existing home would be demolished. Proposed lot sizes would be 5,880 SF. and 5,733 SF. Both new lots would have direct access to Meadow Avenue North via private driveways. The applicant would be required to dedicate 5 feet of width along the street frontage for improvements. There are two significant trees onsite, and no critical areas are present. 3612 Meadow Avenue North REPORT City of Renton & Department of Planning / Building / Public Works DECISION ADMINISTRA TIVE SHORT PLAT REPORT & DECISION A. SUMMARY AND PURPOSE OF REQUEST: REPORTDATE: October 17. 2007 Project Name: Teets Short Plat Applicant/ Contact: Aff:licant: Darcey Teets Contact: Joe Hopper, P.E. 2 8 lO9'h Avenue SE Pacific Ew>ineering Design, LLC Bellevue, W A 98004 1544553' Avenue, S. Smte 100 Seattle, WA 98188 File Number: LUA 07-101, SHPL-A Project Manager: Andrea Petzel, Planner Project Description: Application for administrative short plat approval for a 2-10t subdivision in the R-8 zone. Density would be 7.4 dwelling units/acre. The existing home would be demolished. Proposed lot sizes would be 5,880 SF. and 5,733 SF. Both new lots would have direct access to Meadow Avenue North via private driveways. The applicant would be required to dedicate 5 feet of width along the street frontage for improvements. There are two signifIcant trees onsite, and no critical areas are present. Project Location: 3612 Meadow Avenue North Project Location Map City of Renton P/B/PW Department Administrative Land Use Action TEE1:) SHORT PLAT, PROJECT LUA 07-10f, SIIPL-A REPORT AlVD DEC/SIO/V' D(llnl October 17, 1007 B. GENERAL INFORMATION: 1. Owners of Record: 2. Zoning Designation: Denney and Robin Teets 3 S. Hollow Road Dix Hills, NY 11746 Residential -8 dulac (R-8) Doris J. Pease 16205 SE 9'h Street Bellevue, W A 9800S 3. Comprehensive Plan Designation: Residential Single Family (RSF) 4. Existing Site Use: Existing single family residence to remain 5. Neighborhood Characteristics: 6. 7. North: Single Family Residential (R-S zone) East: Interstate Highway 405 South: Single Family Residential (R-8 zone) West: Single Family Residential (R-S zone) AC'('ess: Site Area: Driveway access off of Meadow Avenue North 12,151 SF (0.2S acres) C. HISTORICAUBACKGROUND: Annexation Comprehensive Plan Zoning D. PUBLIC SERVICES: 1. Utilities: Land Use File No. NIA N/A "IA Ordinance No. IS04 5099 5100 Water: There is an existing 12-inch watermain in Meadow Avenue N. Sewer: There is an existing 8-inch sanitary sewer main in Meadow Avenue N. Surface Water/Storm Water: There are no storm facilities at this site. 2. Streets: There is no sidewalk, curb, or gutter fronting the project site. 3. Fire Protection: City of Renton Fire Department E. APPLICABLE SECTIONS OF THE RENTON MUNICIPAL CODE: 1. Chapter 2 Land Use Districts Section 4-2-020: Purpose and Intent of Zoning Districts Section 4-2-070: Zoning Use Table Section 4-2-110: Residential Development Standards 2. Chapter 4 Property Development Standards Section 4-4-030: Development Guidelines and Regulations 3. Chapter 6 Streets and Utility Standards Section 4-6-060: Street Standards 4. Chapter 7 Subdivision Regulations Section 4-7 -070: Detailed Procedures for Short Subdivisions Page 2 Date 12/S/59 11/1/04 11/1/04 Section 4-7-120: Compatibility with Existing Land Use and Pian-General Requirements and Minimum Standards City of Renton P/B/PW Department Administrative Land Use Action TEETS SHORT PLAT, PROJECT LLiA 07·l()I, SHPL-A REPORT Ai'i'D DECISION' Dated October 17, 2007 Section 4-7-150: Streets-General Requirements and Minimum Standards Section 4-7-170: Residential Lots-General Requirements and Minimum Standards 4. Chapter 9 Procedures and Review Criteria F. APPLICABLE SECTIONS OF THE COMPREHENSIVE PLAN: I. Land Use Element -Residential Single Family 2. Community Design Element G. DEPARTMENTANALYSIS: 1. Project Description/Background Page3 The applicant is proposing to subdivide a 0.2S-acre (12.151 SF) parcel zoned Residential-S (R-8) dwelling units per acre into two lots. The property is located east side of Meadow Avenue North. just north of North 36'h Street. The existing single-family residence will be removed. Proposed net lot sizes are as follows: Lot I: 5.880 SF Lot 2: 5.733 SF There are no street improvements and an approximate 539 SF dedication would be required for installation of half-street improvements. Subtracting that from the gross area of the plat. the proposal for two new lots would arrive at a density of7.4 dwelling units per net acre (dulac). There are no critical areas onsite. Access to both proposed lots would be via separate private driveways from Meadow Avenue North. The site is vegetated with grass and shrubs. as well as two significant trees. 2. Environmental Review Except when located on lands covered by water or sensitive areas, short plats are exempt from SEPA Environmental Review pursuant to WAC 197-II-SOO(6)(a). 3. Compliance with ERC Conditions N/A 4. Staff Review Comments Representatives from various city departments have reviewed the application materials to identifY and address issues raised by the proposed development. These comments are contained in the official file, and the essence of the comments has been incorporated into the appropriate sections of this report and the Departmental Recommendation at the end of the report. 5. Consistency Short Plat Criteria Approval of a plat is based upon several factors. The following short plat criteria have been established to assist decision-makers in the review of the plat: a) Compliance with the Comprehensive Plan Desigllatioll The site is designated Residential Single Family (RSF) on the Comprehensive Plan Land Use Map. Lands in the RSF designation are intended for use as quality residential detached development organized into neighborhoods at urban densities. It is intended that larger subdivision, infill development, and rehabilitation of existing housing be carefully designed to enhance and improve the quality of single-family living environments. The proposal is City of Renton P/H/PW Department Administrative Land Use Action TEETS SHORT PLAT, PROJECT LUA 07-IOI! SHPL-A REPORT AIVD DEClSIDlV Dated October 17, 2007 Page 4 b) consistent wIth the following Comprehensive Plan Land Use and Community Design Element policies: Policy LU-147. Net development densities shouldfall within a range of4.0 to 8.0 dwelling units per acre in Residential Single Family neighborhoods. The proposed project for two lots would arrive at a net density of7.4 dwelling units per net acre, which is within the density range permitted. Policy LU-14S. A minimum lot size of 5,000 SF should be allowed on in-jill parcels of less than one acre (43,560 sq.fl.) in single-family designations. Allow a reduction on lot size to 4,500 SF on parcels greater than one acre to create an incentive for aggregation of land. The minimum lot size is not intended to set the standardfor density in the designation, but to provide flexibility in subdivision/plat design and facilitate development within the allowed density range. Both proposed lots exceed the minimum lot size of 5,000 SF. Policy LU-152. Single-family lot size, lot width, setbacks, and impervious surface should be sufficient to allow private open space, landscaping to provide buffers/privacy without extensive fencing, and sufficient area for maintenance activities. The proposed new lots would meet the required lot size, width, and setbacks to create sufficient front, rear, and side yard areas. Policy LU-154. Interpret development standards to support new plats and infill project designs incorporating street locations, lot configurations, and building envelopes that address privacy and quality of life for existing residents. The proposed lots are would be oriented such that all of the lots would have direct access to a public right-of-way. The two proposed lots would be oriented to face Meadow Avenue Nm·th, thus matching the houses on the abutting lots. Approval ofthis application would not decrease the quality of life for residents in the immediate vicinity. Policy CD-12. In fill development, defined as new short plats of nine or fewer lots, should be encouraged ill order to add variety, updated housing stock, and new vitality to neighborhoods. The proposed short plat would subdivide an existing parcel into two lots. A new residence could be constructed on proposed Lot 2, updating the housing stock in the existing neighborhood. Compliance with the Underlying Zoning Designation The subject site is designated R-S on the City of Renton Zoning Map. The proposed development would allow for the future construction of one new single-family dwelling unit. The allowed density range in the R-S zone is a minimum of 4.0 to a maximum of S.O dwelling units per acre. After subtracting approximately 539 SF for right-of-way dedication, the net lot area is 0.27 acres. The proposal for two lots on 0.27 acres arrives at a density of 7.4 dwelling units per acre, which falls within the permitted density range for the R-8 zone. The allowed building lot coverage for lots over 5,000 SF in size in the R-8 zone is 35 percent or 2,500 SF, whichever is greater. The existing house on Lot I does not comply with setback requirements and will be removed. Staff recommends as a condition of short plat that the applicant obtain a demolition permit and all required inspections completed for the removal of the existing house and garage prior to the recording of the final plat. Both lots comply with the lot size requirements. City of Renton P/B/PW Department Administrative Land Use Action TEETS SHORT PLAT, PROJECT LVA 07-101, SHPL-A REPORT AND DECISION Dated Octoher 17, 2()()7 Page 5 c) d) The required setbacks in the R-8 zone are as follows: front yard is 15 feet for the primary structure and 20 feet for an attached garage; interior side yard is 5 feet; side yard along a stteet is 15 feet for the primary structure and 20 feet for an attached garage; and the rear yard is 20 feet. Both lots provide adequate room [or structures that would comply with setback requirements. The parking regulations require that detached or semi-attached dwellings provide a minimum of 2 off-street parking spaces. As proposed, each lot would have adequate area to provide two off-street parking spaces. Compliance with the parking requirements will be verified at the time of building permit review. Commullity Assets The site is vegetated primarily with shrubs, groundcover and a total of two significant trees, The regulations regarding tree protection/retention require that trees on developable lots be mamtained to the maximum extent feasible, and they permit the City to require the replacement of trees that would implement the intent of the regulations. The Development Services Director has made a determination that to comply with these requirements, 25 percent of all protected trees shall be retained or replaced. Of the two existing trees, one, the 33-inch hemlock in the southwest comer of proposed Lot 1 is proposed to remain. This results in a retention rate of 50 percent and complies with the Director's determination and City regulations, In order to preserve and protect the tree during utility and building construction, staff recommends as condition of approval that the tree be fenced off around the drip line and a sign posted that the tree is to be preserved. The City's landscaping regulations require the installation of landscaping within the public right-of-way. The minimum amount of landscaping required for sites abutting a non-arterial public street is 5 feet, provided that ifthere is additional undeveloped right-of-way in excess of 5 feet, this shall also be landscaped. A determination has been made that if no additional area is available within thc public right-of-way due to required improvements, the 5-foot landscaped strip may be located within private property abutting the public right-of~way. The landscaping proposed shall either consist of drought resistant vegetation or shall be irrigated appropriately. In addition, the applicant will be required to plant two ornamental trees, a minimum caliper of 1-112 inches (deciduous) or 6 -8 feet in height (conifer), within the IS-foot front yard setback area for the proposed lots. Existing landscaping may be used to augment the required landscaping. A conceptual landscape plan was submitted with the application. The plan indicates two street trees on Lot I and only one tree on Lot 2, As a condition of approval staff recommends that a revised, detailed landscape plan with the required street trees, All landscaping shall be installed prior to final inspection of the buildings. Native or drought tolerant species should be used, or an irrigation plan is required, If applicable, fence details should be included in the landscape plan. Allowable fence height is 48" in the front yard (42" in clear vision areas), and 72" in the rear and side yards. Side yards begin fifteen feet back from the front property line. Compliallce with Subdivision Regulatiolls Streets: No new public streets would be created as part of the proposed short plat. Meadow Avenue North is classified as a Collector Street on the City's Arterial Street Map, There are no existing frontage improvements along the parcel's Meadow Avenue North street frontage. The applicant is required to dedicate five feet in width (approximately 539 City of Renton P/B/PW Department Administratiye Land Use Action TEETS SHORT PLAT, PROJECT LlJ.·j 07-101. SHPL-A REPORT AlVD DEC/SIOlV DUt'ed October J 7, lOf)? Page 6 e) SF) for half-street improvements along the parcel's frontage in order to install curb, gutter and sidewalk. The proposed short plat is anticipated to generate additional traffic on the City's street system. In order to mitigate transportation impacts, staff recommends a condition of approval be placed on the project requiring a Transportation Mitigation Fee based on $75.00 per net new average daily trip attributed to the project. One new lot (credit given for the existing residence) is expected to generate approximately 9.57 new average weekday trips. The fee for the proposed short plat is estimated at $717.75 ($75.00 x 9.57 trips x I lot ~ S717.75) and is payable prior to the recording of the short plat. All wire utilities shall be installed underground per the City of Renton Under Grounding Ordinance. If three or more poles are required to be moved by the development design, all existing overhead utilities shall be placed underground. Blocks: No new blocks will be created as part of the proposed short plat. Lots: The size, shape, orientation, and arrangement of the proposed lots comply with the requirements ofthe Subdivision Regulations and the development standards of the R-8 zone and allow for reasonable infill of developable land. Both lots are rectangular in shape and front Meadow Avenue North. As demonstrated in the table below, all lots meet the requirements for minimum lot size depth, and width. Lot Size Depth Width 5,000 SF minimum 50 feet required 65 feet required Lot 1 5,880 SF 107.9 feet 53.8 feet Lot 2 5,733 SF 105.2 feet 53.8 feet Reasonableness of Proposed Boundaries Access: Each lot would have direct access to a public right-of-way via single-family residential driveways. There is an existing garage access easement on proposed Lot 2 (Rec. # 9312102007) that the applicant proposes to relinquish. Because any new structure would be unable to meet setback requirements on this lot with the easement still in place, staff recommends as a condition of approval that the easement be relinquished prior to recording the short plat. Topography: Both proposed lots are relatively level; however, there is a significant grade change of approximately 13 feet between Lots I and 2, with an existing retaining wall. In order to address the grade change the applicant submitted a geotechnical report from Geotech Consultants, Inc. (dated July 27, 2007). Both lots will be graded so that each lot has a somewhat flat grade; the southern lot will be higher than the northern not, which is consistent with existing conditions. The report found no groundwater seepage or unusual soil conditions. In order to protect the integrity of the future homes, staff recommends adhering to the recommendations made in the geotechnical report. Because the applicant has not decided on the amount of grading that will be done to level the site, it should be noted that if more than 500 cubic yards of fill is moved, Environmental Review (SEPA) will be required. City of Renton P/B/PW Department Administrative Land Use Action TEETS SHORT PLAT, PROJECT LlIA 07-101, SHPL-A REPORT A/,liD DEC/SIOIV Daled October 17, 2007 Page 7 1) Relationship to Existiflg Uses: The properties surrounding the subject site are single-family residences and are designated R-8 on the City's zoning map. The proposal is similar to existing development pattems in the area and is consistent with the Comprehensive Plan and Zoning Code, which encourage residential infill development. Availability and Impact on Public Services (Timeliness) Police and Fire: Police and Fire Prevention staff indicate that sufficient resources exist to fumish services to the proposed development, subject to the condition that the applicant provide Code required improvements and fees. A Fire Mitigation Fee, based on $488.00 per new single-family lot with credit given for the existing single-family residence, is recommended in order to mitigate the proposal's potential impacts to City emergency services. The fee is estimated at $488.00 ($488.00 x 1 new lot = $488.00) and is payable prior to the recording of the short plat. Street addresses shall be visible from a public street. Schools: According to the Draft Environmental Impact Statement for the City of Renton Land Use Element (January 16, 1992), the City of Renton has a student generation factor of 0.44 students per single-family residential dwelling. Based on the student generation factor, the proposed short plat would result in 0.44 additional students (0.44 X 1 lot = 0.44) to the local schools. It is anticipated that the Renton School District can accommodate any additional students generated by this proposal at the following schools: Kennydale Elementary, McKnight Middle School and Hazen High School. Surface Water: The runoff from the new lot must use infiltration per design by a professional engineer, or be tightlined into the storm drainage system or other options as listed in, and in accordance, with the 1990 King County Surface Water Design Manual. Infiltration is allowed if the soils are acceptable. The Surface Water System Development charges are required, and based on a rate of $759.00 per new single-family lot (estimated total of $759.00 with credit for the existing lot). Payment of this fee will be required prior to issuance of utility construction permit. A temporary erosion control plan will be required and shall be installed and maintained to the satisfaction of the representative of the Development Services Division for the duration of the project. This includes installing a silt fence along the perimeter of the site that is to be disturbed. The silt fence shall be in place before clearing and grading is initiated. This will be required during the construction of both off-site and on-site improvements as well as building construction. Due to the potential for erosion to occur during project construction, staffrecommends as a condition of approval that the project be required to comply with the Department of Ecology's Erosion and Sediment Control Requirements as outlined in Volume II of the 2001 edition of the Storm water Management Manual. Water: This project is required to provide separate domestic water service stubs for the new lots prior to recording the short plat. New water service stubs must be installed prior to recording of the short plat. Water System Development charges are based on a rate of $1,956 per new single-family lot (estimated total of $1 ,956.00 with credit for the existing lot). Payment of fees is required prior to issuance of utility construction permit. All plats are required by City Code to provide a fire hydrant with a minimum fire flow requirement of 1,000 GPM within 300 feet of any proposed single-family structure. If the proposed single-family structures exceed 3,600 SF, the minimum fire flow increases to 1,500 GPM and requires two hydrants within 300 feet of the structure. Any existing hydrant counted as fire protection will require installation of a "storz" quick disconnect fitting ifnot already in place. It appears an existing hydrant at the corner ofN. City of Renton P/B/PW Department Administrath:e Land t:sc Action TEETS SHORT PIA T, PROJECT LUA 07-10/, SHPL-A REPORT AND Dl::ClSION Dated October 17, 2007 Page H 36 th and Meadow Avenue may be within 300 feet. The engineer is required to show location of all existing hydrants on plan sheets. A new hydrant may be required. Sewer: Installation of individual side sewers by the developer is required prior to recording the short plat; dual side sewers are not allowed. The minimum slope for side sewers is 2%. Sanitary Sewer System Development Charges are based on a rate of $1,017.00 per new single-family lot (estimated total of$1 ,017.00 with credit for the existing lot). Payment of this fee will be required prior to issuance of utility construction permits, and prior to recording the short plat. H. FINDINGS: Having reviewed the written record in the matter, the City now enters the following: 1. Application: The applicant's short plat application complies with the requirements for information for short plat review. The applicant's short plat plan and other project drawings are contained within the ofticialland use file. 3. Comprehellsive Plall: The subject proposal is consistent with the Comprehensive Plan designations of the Residential Single Family (RSF) land use designation. 4. Zoning: The proposal as presented complies with the zoning requirements and development standards of the R-8 zoning designation, provided all advisory notes and conditions of approval are complied with. 5. Subdivisioll Regulations: The proposal complies with the requirements established by the City's Subdivision Regulations provided all advisory notes and conditions are complied with. 6. Existing Land Uses: The short plat is consistent with development and uses surrounding the subject site, including: North: Residential Single Family (zoned R-8); East: Interstate Highway 405 South: Residential Single Family (zoned R-8); and West: Residential Single Family (zoned R-8). 7. System Development Charges: A Water System Development Charge, a Surface Water System Development Charge and a Sewer System Development Charge, at the current applicable rates, will be required for the each new Single-family residence as part of the construction permit. 8. Public Utilities: The applicant will be required to install individual sewer and water stubs to serve the new lots. In addition, installation of a fire hydrant may be required. l. CONCLUSIONS: 1. The subject site is located in the Residential Single Family (RSF) comprehensive plan designation and complies with the goals and policies established with this designation. 2. The subject site is located in the R-8 zoning designation and complies with the zoning and development standards established with this designation provided the applicant complies with City Code and conditions of approval. 3. The proposed two lot short plat complies with the subdivision regulations as established by City Code and state law provided all advisory notes and conditions are complied with. 4. The proposed two lot short plat complies with the street standards as established by City Code, provided the project complies with all advisory notes and conditions of approval contained herein. City of Renton P/B/PW Department Administrative Land Use Action TEET.\' SHORT PLAT, PROJECT LUA 07~IOl, SHPL-A REPORT AI\iD DECISION Datt'd October 17, Z007 J. DECISION: The Teets Short Plat, File No. LUA 07-101, SHPL-A, is approved subject to the following conditions: 1. The applicant shall obtain a demolition permit and all required inspections completed for the removal of the existing house and garage prior to the recording of the short plat. Page 9 2. In order to preserve and protect the one significant tree during utility and building construction the tree shall be fenced off around the drip line and a sign posted that the tree is to be preserved, and the location of the tree shall be indicated on all utility construction plan sheets. The fencing shall be in place prior to the issuance of any utility construction permits and shall remain until the final inspection of the new house on Lot 2 is complete. 3. The applicant shall submit a revised, detailed landscape plan indicating the required street trees. The plan is subject to the review and approval of the Development Services project manager and is required prior to the issuance of the building permits. 4. The applicant shall pay the required Transportation Mitigation Fee based on $75.00 per net average daily trip prior to the recording of the short plat. 5. The garage access easement (Rec. #9312102007) shall be relinquished prior to recording the short plat. 6. The applicant shall adhere to the recommendations of the geotechnical report from Geotech Consultants, Inc. (dated July 27,2007). 7. The applicant shall pay a $488.00 Fire Mitigation Fee prior to the recording of the short plat. 8. The project shall be required to comply with the Department of Ecology's Erosion and Sediment Control Requirements as outlined in Volume II of the 2001 edition of the Stormwater Management Manual. DATE OF DECISION ON LAND USE ACTION: TRANSMITTED this 161 ;' dayafOctober, 20U7 to the Applicant/Owner/Contact: Applicant Darcey Teets 2838 l09 lh Avenue SE Bellevue, W A 98004 Owner: Denney and Robin Teets 3 S. Hollow Road Dix Hills, NY 11746 Contact: Joe Hopper, P.E. Pacific En}inccrin g Design, LLC 1544553' Avenue, S. Suite 100 Owner: Doris J. Pease 16205 SE 9'" Street Bellevue, W A 98008 TRANSMITTFD this J 61h day of October, 2007 to the Parties of Record. There are no partics of record. ~ Decision Date City of Renton P/B/PW Department Administrative Land L;se Action TEETS SHORT PLAT, PROJECT LUA 07-10/, SHPL-A REPORT AND f)tXISIOlV Dated October 17, 2007 TRANSMITTED this 16rh day a/October, 2007 to thefoflm~'illg: Larry Meckling, Building OfficIal Bob Van Horne, Deputy Fire Chief ~cil Watts, Development Services Director Jennifer Henning, Current Planning Manager Jan Conklin Carrie Olson Renton Reporter Lund Use Action Appeals & Requests for Reconsideration The administrative land use decision will become tlnal if the decision is not appealed within 14 days ofthe effective date of decision. An appeal of the decision must be tiled within the 14-day appeal period (RCW 43.2LC.075(3); WAC 197-11-680). Page 10 RECONSIDERATION. Within 14 days ofthe effective date ofthe decision, any party may request that a decision on a short plat be reopened by the Administrator. The Administrator may modify his decision if material evidence not readily discoverable prior to the original decision is found or if he tlnds there was misrepresentation of fact. After review of the reconsideration request, if the Administrator tlnds insuftlcient evidence to amend the original decision, there will be no further extension of the appeal period. Any person wishing to take further action must tile a formal appeal within the following appeal time frame. APPEAL. This administrative land use decision will become tinal if not appealed in writing to the Hearing Examiner on or before 5:00 PM on OCTOBER 31,2007. City of Renton Municipal Code Section 4- 8-110 governs appeals to the Examiner. Additional information regarding the appeal process may be obtained from the Renton City Clerk's Omce, (425) 430-6510. Appeals must be tiled in writing, together with the required $75.00 application fee, to: Hearing Examiner, City of Renton, 1055 South Grady Way, Renton, WA 98055. EXPIR4.TlON DATE: The Short Plat approval will expire two (2) years from the date of approval. An extension may be requested pursuant to RMC section 4-7 -080.M. City of Renton P/B/PW Department Administrative Land Vse Action TEETS SHORT PLA1~ PROJECT LlIA 07-10/, SHPL-A REPORT AND D£C1SIOl\r Dated October J 7,1007 ADVISORY NOn'S TO APPLICANT Page 11 The following notes are supplemental information provided in conjunction with the administrative land use action. Because these notes are provided as in/ormation only, they are not subject to the appeal process/or the land use actions. Planning 1. RMC section 4-4-030.C.2 limits haul hours between 8:30 am to 3:30 pm, Monday through Friday unless otherwise 2. approved by the Development Services Division. The Development Services Division reserves the right to rescind the approved extended haul hours at any time if complaints are received. A detailed landscape plan shall be submitted at the time of building permit application. The landscape plan will include ornamental trees in the front yard of each lot and the 5' foot landscape strip. 3. Ifmore than 500 cubic yards offill is moved, Environmental Review (SEPA) will be required. Propelty Services 1. To be sent under separate cover. Fire 1. A fire hydrant with 1,000 GPM fire flow is required within 300 feet of all new single-family strucrnres. If the building square footage exceeds 3,600 sq. ft. in area (including garage), the minimum fire flow increases to 1,500 GPM and requires two hydrants within 300 feet of the struchrres. The applicant should note that the fire flow available to the site is 1,000 GPM, therefore no residences over 3,600 SF in area can be permitted on the subject site due to fhe limited fire flow available. 2. All building addresses shall be visible from, or posted at, the public street. 3. Any existing hydrant counted as fire protection will require installation of a "storz" quick disconnect fitting if not already in place. It appears an existing hydrant at the comer ofN. 36'" and Meadow may be within 300 feet. The engineer is required to show location of all existing hydrants. A new hydrant may be required. Plan Review -Sewer 1. Sanitary Sewer System Development Charge is $1,017.00 per new single-family lot. Payment of this fee will be required prior to issuance of utility construction permit. 2. Separate sewer stubs are required for each ne\v lot prior to recording of the short plat. 3. Minimum slope for side sewers shall be 2%. Dual side sewers are not allowed, Plan Review -Surface Water 1. The Surface Water System Development Charges are based on a rate of $759.00 per new single-family lot. Payment of this fee will be required prior to the issuance of a utility construction permit. 2. Roof drains shall be tightlined to the storm system whenever feasible. 3. A conceprnal drainage plan and narrative is required. This project is exempt from detention and water quality per the 1990 KCSWM. 4. A temporary erosion control plan will be required and shall be installed and maintained to the satisfaction of the representative of the Development Services Division for the dmation of the project. Plan Review -Streets/Transportation. 1. Half street improvements inc hiding sidewalk, curb, and gutter~ paving and storm drainage are required to be installed fronting the site in Meadow Ave N. Applicant may submit a request to Public Works to pay a fee in lieu of installing these improvements. 2. Applicant will bc required to dedicate five feet of right-of-way fronting the site in Meadow Ave N. Existing right of way widlh is 40 feet. Minimum right of way width is fifty feet. It is shown on the plans. 3. Street lighting is not required for a two lot short plat 4. Applicant will be required to comply with the City of Renton's Trench Restoration and Street Overlay Requirements. 5. A u·affic control plan, approved by the City will be required for any construction impacting the City's right of way. 6. Maximum driveway slope is 15%. Miscellaneous 1. Separate permits and fees for side sewer connections, water meters, and stonn drainage connections are required. 2. Applicant shall be responsible for securing all necessary easements for utilities. 3. Proposed new rockeries or retaining walls to be constructed that are greater than four feet in height (from bottom of footing to top of wall) will be require a separate building permit for strucrnral review. A geotechnical report is required with the submittal. 4. All wire utilities shall be installed underground per the City of Renton Under Grounding Ordinance. [fthree or more poles are required to be moved by the development design, all existing overhead utilities shall be placed underground. CDR St 0<:;' ~ <[ U CA CA .~ ;:§ ~§. R-8 00 I R-8:: rY N 38th R-8 N 37th N 36tli St R-8 N 35th St R~8 lj/R-8N 34th St R-'-83 N .33td.PIR-8/ Iv 331 d 3 t R-S / R-S/ R-S N 31st 3t R-S / P- St ~ R-8 N 34th st R-8 N 32nd St. R-8 J~~=lER-S N 30th St R-Sffiij r-~CN--J II~~==I/ R -8· N 29th St R-E t----, N 2tlth l"l R-S / ~~ ~ ZONING o = TIICIINlCAL BBRVICES -----RentDn Cit, Llmif41 R CN o 200 .00 C4 1,4.800 32 T24N R5E W -)NING MAP BO-K 9829383 ~~ '8S" 45B6:'~7~ 25 T24N R4E 30 T24N RSE 19 T24N ASt=: 2~ T24N A5E '27T24N RSE 26 T24N ~5E 74W 81 26 T24N R4E 81 IC1 35 T24N R4£ . 455W )457 i 458 . .....•... 460 ... 464: C2 C3/C4~C5CS =C7 36 T24N R4E 31 T24N A5~(_;:-3~-~24N ~5E--:---'~'--3-~N F.i.E--~".+3a:'~<lJ';t~ 35 ~4N ASE 94W , {l.T23N R5E 306 ~ ID1 2 T23N R4E 307 ,,8G8 '309 D3 \04 5'~23N R5E 3Q§_~ 80&! 807 4 T23N R5E - 3 T23N ASE r: 2 T23N R5E " 3~6 : , ",-! 132 $"" 326 i'i{3p I 328 370 810 -8[11 I .. ,.. .-:e.. ·rn F1\'v~~ r3F4 F5 ~rre-Lr' 4 T23N -~4~ ,-\ '13;-T23N R4E 18 T23N R5E 17 T23N A5E 16 T23N RSE '1kT2st.J R5E :. 14 T23N RSE 334 --:-\335 336 337 .. 371 .. 815l·· 816 <31 '(32 I G3G4~~--LrG&-G7 3T23NR41: 24T23NR4E 19T23NR5E 20T23NRSE' 21T23~ 22T23NR5E 23T23NR5E 34J 600 601;.£7·· 602 .. .... 820 821 " 1 ~h "'-HI: 2 H· 3 ..... l-aJA I 'I r1" .. 2,s-T23!W R4E _ ,/. 30 T23N R5E -~29 23N RSE 28 T23N R5E 344 ttl H5 . HS··H7 27 T23N R5E 26 T23N ASS: ---25 605 825 826 • 1 . 8 15 IS 17 33T23N R& 34 T23N R5E 35 T23N R5E 632 833 e JS J7 22N R4E 1 T22N R4E 4 122N A5E 5 T22N R5E 3 T22N R5E 2 T22N R5E [A 1 Y~l 6 T22N R5E RESIDENTIAL ~ Resource Conservation ~ Residential 1 dulac ~ ReBwentilll " dulac ~ Residential 8 dulac ~ Residential Manufactu~ed HomeR I R-IO I Residential 10 dulac I R-141 Residential 14 dulac I R",-FI Reeidential Multl-FemHy I RM-T I Residential Multi-Family Traditional I RM-U I Reaidential Multi-Family Urban Center" Printed by Print & Mail SeRVices, City of Renton MIXED USE CENTER ~ Center Vill6.8e Iuc-NII Urban Center -North 1 IUC-N21 Urban Center -North 2 ~ Center Downtown.- ~ Commercial/Office/Residential COMMERCiaL ~ Commercial Arterial· ~ Commercial Office" ~ Commercial Nei,hbl>rhl>od INpUSTRIAL ~ InduBlrisl -HeaV)' o Industrial -Medium o Industrial -Light (P) Publicly owned ____ Renton City Jjroi18 _"_. __ AdjB.cent City Umits _ Bl>ok Pages Boundary KROLL PAGE • May include O .. erlay Distric.t.&. S~e Appendix maps. For additional relUlations m Overlay Distrlc18. please Ree Rye 4-3. PAGE# INDEX SECT'TOWtN'IANGE SHORT PLAT NO. r PORTION OF THE S. E. 1/4, N. W. 1/4, SECTION 32, TWP. 24 N., RGE. 5 E., lI:M. LUA-XX-XXX-SHPL um-lX-XDJ: ~ KING COtINTY. If'A8HlNGft)N LAJ<E WASHINGTON • CERTIFICATE I (WE) tIED'!' C(RTfY TH,I,T I ..... ('11£ ARE) '!HE OIlWER(S) IN Ft[ 5IYPL.E Of THE I.J,N[) HERE8~ PI,.lTlEO IN THIS 910111 ~,. ~N~ "~~DSEP~,,\:H~§ftf' AND IW't ACKNOWLEDGWENT STAlE Of WA5HINUTON) "' COUNlY Of KING ) ON '!HIS 0"''' PERSONAUk -:;~: sgc:~ ~E"~"'"""''''''')',"'''''''''''''~"'= THE FCR£1XlING INSTRUfojENT, lIND ACKNOWUDDED 1I1Al SAIl lHSlIIUIIIEHT TO lIE THE rltEE ~ WLUNTARY ACT AHO DEED OF THE SIIlD I'O!SOH(S), fOR 'll£ !,IstS AND ~P05(S THEREIN 1lA!H1I0NED. AND ON OATH ST ... lED T11Al THEY 'II£R£ AUlHOIIIZW TO EXECUTE THE 5,1,10 lHSTRUW£NT. 1lI\Oi UI'IID£R MT HANO AND SEAL THS _ DAY Of 2001. NOTARY IiiJ8IJC IN IHJ fOR tilE stAn Of WAStlHGTOH RESIDING AT APPROVAlS CITY OF RENTON ElWIWED AND ~ THIS __ 0 ... ,. OF ____ 2007. -i\iii,jIHJSTltATOR Of PLA~"G/llUILD"G/PUklC '/IOiij(S KING COUNTY [XAIoIINE!J AND APPIIO'IED lliIS __ O"y Of ____ =. DEPAA'lMENT Of AsSi:Sswairs -IXPARlWENT 01' ASS£SSr.IENTS ICING COUloflY ,o,$$($$OR DEPUTY KING COUNTY ASSESSCfI LEGAL DESCRIPTION PlR RNNIER nll..E COMPANY. E4STSlDE 11M UNIT, JltPOIiIT ORO£R No. ~141 DllTED f,lJl;ILISl D. 2006. lR4eT 122 OF" C,D. ttl..l.WoW's LAK.E w.o.sHNGTON ~ OF EDEN ~ TO SEltTTLE No.2. AS PlR PLA1 f!£CDROED IN VOW..: II Of PLATS., PAQC 114, RECORDS Of KlN(l. COUNTY foi.A)IlIIR; £XC£P1 ~T POATION LYlNO WITHIN s(OOr.ItWIY ST ... TE ItIGttWAY NUMB£A 2-k SIT\.IIoTE IN "!HI: ~ Of IONC. STATE OF" WASHNGlQIoI. ~ I '"' 1 ... OJ 1 :00 I ~ 1 8 I'" 1 r:l 15 1 ::E '" 81 20' I W I #0\ .;J LOT 1 1 LOT2 ~. LOT 121 m·1 ,. <j>-' InT AREAS LOT 1 MIlO s.r. OR o.a ...... '"/- LOT 1 !>,7J! s.r. OR O.U ... ." +-/- !>' 'tOW O£OICAliON Me !or. OR 0.01 "'Co +/- .~, 101,1,1.._ Of' PROPOSED PUlT 12,151 s.r. OR 0.28 ""=-+/- DECLARATION OF COVENANT ~" ~" THE (W;£II Of' lHE t.ANJ D&lACED M1tIN THS SHORT PLItT. IN REllII'tN !'OR TIt( BENEFl1 TO ACCR\.I: /lIOM THS SUilDM5ICIIi, BY _ HEREON OOVENANlS AND _us TO CON""Y THE IIENEFICIAL IN'IEREST III THE NEW EASDl[NT 5ttOIWI CiII THS SHORT PLItT TO AN'" NIl) Itll. F1JlUIIE PI.IRCHfoS(RS OF" THE lOTS, OR or ANT SUBDMSIONS lHEREOf. lHlS ~T SttIoU _ \IIIlH 1M[ LAND AS stID'MoI CiII TttIS SHOAT PLItT. RJ';CORpmrS cBRTIfK'!ATR I I I I I I 0' i -$- 1" = 30' 30' 60' -NfoI) 181.1191 BEAAlI<IIl \<ER11CAL DltWIl IS Nlto,o 1~ SITE: ADOIIESS 3612 OI£,\OOW ItVl: N., RENTON. ..... MOM DItIGI"""-ToUt PAACEL , ~27O()e17 ----------f-----LEGEND SS _ SANlT ... RY SEII£R so .. STORII $EWER Il _ o...s UN[ L() 71 -, 014'-OIiUttW PO'IO: lINE W _ ...... T£RIJI<IE I> -QI.S VItl.YE II' _Wlt1UVItl.>E mI -WitTER WEYER tf .. FIRE tt'ltlR1tN1 • .. CArat SItSIN o -1U.NHW: -0 _ UTLlT't POlE o -UGIIT f'()$f tt _ GU1' ANCHOR ~.-I[J .. POWER VltUlT/THANSI'CRIER m .. lElLfTV P[II. e .. PARKI,... METER T TO BE R£i.JNQUISHEI) r em tsM" -------- • .. SEC1ION CORNER I .. QUARTER OORNER e .. fl«>. WON, IN CASE o _ fIiD. PROP. COR. AS HOlD) • _ SET 1/1" lR. W/CAP 1114&4 (r;:QII) .. em' Of IIDITON (R) __ I!ECORO I I I CIVIL ENGINEER: ~Ef~ DESIGN, Ll.C ...... HI8111 Pt/OIIC!(2aa) 4Jf_n11l FAX:(2tNI) -,~ ~~~~~_FAX: ---------)------ZQtIING: ~-II NEW LOT ADDRISSES MEADOW liVE 1'1, RENlON. WA 9lI0:I(I MEADOW It~ N, RENlON. WA 9_ SUR"I:Y IEETS OR EXCEIDS n-t: IIl!:OJIRDIIENTS Of W#;; 3.l2-1»-0II0. ECIJIP\IENT IJS[I), ~. T01 .... STATION. SI.IIIIIU ILTJIOO: F1ELJ) 'lRAo,£RSE. RELAlI'.t: POSIllON.O.l. -rr::uR.\NCE 01 SET CCIRNEJIIS: +/-0.1' TEETS SHORT PLAT DOISlT't PElMTED: II DU/:t'; DENSiTY PROI'OS£D: 7.~ %A<:. PRCFOSED HW8£R OF LO ,f' Jl,-_~~"~.~.~_ .. , BENCH IIARK ~ DA1UW: ""'00 aa BOtCH WARKl mY OF RENlON BENCH WMK , 2100 I'M). " STANON'ICI USOS IDle IU.RK BRASS DI!J( ~G~~Y-il':r~~~ (.V> IOJSIHQ OM W. SIDE OF LJ( WI. 1IL'oO. EltVAlION _ 28.11 fEET P1IIP.dID B't. -~'" LATEST!t['Ot$IOH: 05/14/07 !UpmymrR cpmnCATB _) TttIS ..... P CQltR[Cl\. Y IIP'lII[:sI!HlS ... SJI!\I£Y MAtl£ IlY r.I£ OR U~ IN al!tCYlOll 1H ~_"lH '»1£ 1I£0I,I,IIIIEIiENTS 01 lHE SI.IIMY RECOftDIHCltCT,ltT·1Ht·A~CI".':7 ;.~ fllLD FOR RECDNl lHlS __ D ... .,. OF 20_ AT ------N. IN IIOOIt ___ ~ ____ U P.o.cE ___ _ S.E. 1/4, N ..... 1/4, SEC. 32, TWP. 24 N., RGE. 5 E., "".IL CITY OF RENTON, KING COUNTY, WASHINGTON A AT 'JI1E REQUEST 01' RODNEY C, IiAHSEN. '~'~~7.:J0!-J'-:":.:';.<. ";~,--,.""' .. ,:",:~~t( h N_ , '. Ifit,,'1E "10. tl444 _'''' UT. 01' ItECOROS G::f. ~:.: .. ~'~ ~~!. ~-~; CITY OF RENTON FILE No. W-,- OWN BY; PJC DATE: 5/14/07 I JOB NO. 20714 CHKD BY: RGH SCALE: ,"",20' SHEET , OF 1 HANSEN SURVEYING lAND SURVEYORS. CONSUlTANTS 11420 IIBlH "''wE. S.£., RENTON. WA 98058 lEI.: 425-2:»-&+40 fAX: 42!.-2M-02fIB , I I , , I ! =---liLii ~---- 1 \tld HlOHS S133.1 z o F z W >-W De ~:5 WZI >-0. z :5 "- '" z F z :5 "- ! • III ~ !Ii - hi 'I '" lit; ~. :~' ~: ",!" . J •.•. ~" " .' ~,! ; {:--. ~ ., ,-,,~:, c ~', . '" :t;':,\ J~; · ..... ·1 '" ~ ..... ~ ~ ui I/) a: z ;lj t-= c.j '" ~ ~ CD ..f -~ ~ ..f -~ III w j!: LL 0 Z 0 ~ 2 -. I ~ ._-- -- il - il 1 -- I I I 1 -- ~ . " . .;-~i~t_' ''-''::oF. "~,,, ....... ,', :'j"l( .. :' "''"''''"; • <,t.'-. _I: 9OV-1 If '---- " '. if':; -~~~ ______ ~~ __ ---=-__________ i0' I:~ -l -----~,-­ I , ",' I, "", I',> ...:.' • ," L] ,. c~ ~ >"" ,~: ::-:~. ,. ',< - • ~ ;: y , /, '~:~~J':i: . .,.., , , " '.~ . _ ..... ) ,~-:::, .' .z: 1 'I l ---- -- ---- 8lIl\!J. . 3tJ!UUl1[d pw '1Iu31fA!:J :JTI 'u>l!S"O :3uu~~ul~U3 ::'YPRd ~ ! . ~i Ul ~d ~, r ~ nil rll i ~!!!: it I I~ ~ ~: ~ 8 I T""" ~ o. 0...1 ! I ! In I~ I IH I; !H & n fi I ~ S ~ . ~ 1_ -li--·--j-----1-_·_[ r- City a nton Department of Planning I Building I Pu Yorks ENVIRONMENTAL & DEVELOPMENT APPLICATION REVIEW SHEET REVIEWING DEPARTMENT: il1J1Le COMMENTS DUE: OCTOBER 5, 2007 APPLICATION NO: LUA07-101, SHPL-A DATE CIRCULATED: SEPT APPLICANT: Darcey Teets PROJECT MANAGER: "drea'Petzel /~ PROJECT TITLE: Teets Short Plat PLAN REVIEW: Jan lilian SITE AREA: 12,151 square feet BUILDING AREA jgross): N/A 10: LOCATION: 3612 Meadow Avenue N I WORK ORDER NO: 77808 SUMMARY OF PROPOSAL: Application for administrative short plat approval for a 2-lot subdivision in the R-8 zone, Density would be 7.5 dwelling units/acre, The existing home would be demolished. Proposed lot sizes would be 5,880 sq. ft. and 5,733 sq. ft. Both new lots would have direct access to Meadow Ave. N via private driveways. There are two significant trees onsite, and no critical areas are present. A. ENVIRONMENTAL IMPACT (e.g. Non-Code) COMMENTS Element of the Probable Probable Mo,. Element of the Probable ProbabJe More Environment Minor Major Information Impacts Impacts Necessary Environment Minor Major Information Impacts Impacts Necessary Earth Housing Air Aesthetics Water Light/Glare Plants Recreation Land/Shoreline Use Utifities Animals Transportation Environmental Health Public Services ---Energy/ Historic/Cultural Natural Resources Preservarion Airport Environment 10,000 Feet 14.000 Feet B. POLICY-RELA TED COMMENTS C. CODE-RELATED COMMENTS We have reviewed this application with particular attention to those areas in which we have expertise and have identified areas of probable impact or areas where additional information is e ed to pro erly assess this proposal. IIJ-9-o'1 Date City 0 nton Department of Planning I Building I Pu. . larks ENVIRONMENTAL & DEVELOPMENT APPLICATION REVIEW SHEET REVIEWING DEPARTMENT: COMMENTS DUE: OCTOBER 5, 2007 APPLICATION NO: LUA07-101, SHPL-A ' DATE CIRCULATED: SEPTEMBER 21,2007 APPLICANT: Darcey Teets PROJECT MANAGER: Andrea Petzel PROJECT TITLE: Teets Short Plat PLAN REVIEW: Jan lilian C'.!, J Q .: (. r SITE AREA: 12,151 square feet BUILDING AREA (qross): N/A LOCATION: 3612 Meadow Avenue N I WORK ORDER NO: 77808 ;)I:.r £ I I..'J~ I SUMMARY OF PROPOSAL: Application for administrative short plat approval for a 2-lot subdivision in the ~(i)Iil\\lIt9IQ.W,ld be 7.5 dwelling units/acre. The existing home would be demolished. Proposed lot sizes would be 5,880 sq. ft. and 5,733 sq. ft. Both new lots would have direct access to Meadow Ave. N via private driveways. There are two significant trees onsite, and no critical areas are present. A. ENVIRONMENTAL IMPACT (e.g. Non-Code) COMMENTS Element of the Probable Probable More Element of the Probable Probable More Environment Minor Major Information Environment MinoT Major Information Impacts Impacts Necessary Impacts Impacts Necessary Earth Housing Air Aesthetics Water Li htlG/are Plants Recreation Land/Shoreline Use Utilities Animals Transoortation EnVJ{onmental Health Public Services Energy! Historic/Cultural Natural Resources Preservation Airport Environment 10,000 Feet 14.000 Feet B. POLICY-RELA TED COMMENTS C. CODE-RELA TED COMMENTS We have reviewed this application with particular attention to those areas in which we have expertise and have identified areas of probable impact or areas where additional information is needed to properly assess this proposal. Signature of Director or Auth Date City a .nton Department of Planning I Building I Pub, larks ENVIRONMENTAL & DEVELOPMENT APPLICATION REVIEW SHEET REVIEWING DEPARTMENT: P(VK.s COMMENTS DUE: OCTOBER 5, 2007 APPLICATION NO: LUA07-101, SHPL-A DATE CIRCULATED: SEPTEMBER 21, 2007 APPLICANT: Darcey Teets PROJECT MANAGER: Andrea Petzel PROJECT TITLE: Teets Short Plat PLAN REVIEW: Jan lilian SITE AREA: 12,151 square feet BUILDING AREA (woss): N/A LOCATION: 3612 Meadow Avenue N I WORK ORDER NO: 77808 SUMMARY OF PROPOSAL: Application for administrative short plat approval for a 2-lot subdivision in the R-8 zone. Density would be 7.5 dwelling units/acre. The existing home would be demolished. Proposed lot sizes would be 5,880 sq. ft. and 5,733 sq. ft. Both new lots would have direct access to Meadow Ave. N via private driveways. There are two significant trees onsite, and no critical areas are present. A. ENVIRONMENTAL IMPACT (e,g, Non-Code) COMMENTS Element of the Probable Probable More Element of the Probable Probable More Environment Minor Major Information Impacts Impacts Necessary Environment Minor Major Information Impacts Impacts Necessary Eal1h Housin< Air Water Plants Land/Shoreline Use ~on Animals Environmental Health Public Services Energy/ Natural Resources A:~~nFPPf ,; nnn <"of B. POLICY-RELATED COMMENTS C, CODE-RELA TED COMMENTS We have reviewed this application with particular attention to those areas in which we have expeJ1ise and have identified areas of probable impact or areasw~:~assessthisproposal. v~( .. Signature of Director or Authorized Representative Date j DATE: TO: FROM: SUBJECT: FIRE DEPARTMENT MEMORANDUM September 26, 2007 Andres Petzel, Associate Planner Camille Walls, Acting Assistant Fire Marshal Teets Short Plat -3612 Meadow Ave N Fire Department Comments: L A fire hydrant with 1000 GPM fire flow is required within 300 feet of all new single- family structures. If the building square footage exceeds 3600 square feet in area, the minimum fire flow increases to 1500 GPM and requires two hydrants within 300 feet of the structure. 2. A fire mitigation fee of$488.00 is required for all new single-family structures. 3. Fire department access roadways are required to within 150 feet of all portions of the building exterior. Roadways are a minimum 20 feet in width with a turning radius of 45 feet outside and 25 feet inside. 4. All building addresses shall be visible from or posted at the public street. Please feel free to contact me if you have any questions. c;\documents and settings\cwalls\desktop\plat-2007\teets short plat.doc 1 Cily 'nlon Department of Planning! Building! p, Works ENVIRONMENTAL & DEVELOPMENT APPLICATION REVIEW SHEET REVIEWING DEPARTMENT: r I r-c.-COMMENTS DUE: OCTOBER 5, 2007 APPLICATION NO: LUA07-101, SHPL-A DATE CIRCULATED: SEPTEMBER 21,2007 APPLICANT: Darcey Teets PROJECT MANAGER: Andrea Petz€i'------: '.- PROJECT TITLE: Teets Short Plat PLAN REVIEW: Jan lilian SITE AREA: 12,151 square feet BUILDING AREA (Qross): NIA LOCATION: 3612 Meadow Avenue N I WORK ORDER NO: 77808 6t,.. 2 1 2007 SUMMARY OF PROPOSAL: Application for administrative short plat approval for a 2-lot subdivisicm in the-R.f\~t?FI!l:,~QeASit)L.wQlJld be 7,5 dwelling units/acre. The existing home would be demolished. Proposed lot sizes would be 5,880 sq. It. ana 5',733' sq. ft. Both new lots would have direct access to Meadow Ave. N via private driveways. There are two signtiicanl.i:reeS bnsite, and no 'critical areas are present. ---- -___ I A. ENVIRONMENTAL tMPACT (e.g. Non-Code) COMMENTS Element of the Probable Probable Mo," Element of the Probable Probable More Environment Minor Major Information Impacts Impacts Necessary Environment Minor Major Information Impacts Impacts Necessary Earth Housing Air Aesthetics Water Light/Glare Plants Recreation Land/Shoreline Use Utilities Animals Transportation Environmental Health Public Services Energyl Historic/Cultural Natural Resources Preservation Airporl Environment 10,000 Feet 14,000 Feet B. POLICY-RELA TED COMMENTS C, CODE-RELA TED COMMENTS -4 r::2«a C4-cdd &171. OM t?0 We have reviewed this application wUh particular attention to those areas in which we have expertise and have identified areas of probable impact or ar1 where ad~iti~nal information is needed to properly assess this proposal. {'1it2~iJC(/ tV/( -Udz../ -0//;;&#2 Signature of Director or Authorized Representative Date DATE: TO: FROM: SUBJECT: CITY OF RENTON MEMORANDUM September 24, 2007 Andrea Petzel Jan Illian x 7216 TEETS SHORT PLAT 3612 -Meadow Ave N. LUA 07-101 I have reviewed the application for this short plat located 3612 -Meadow Ave N. and have the following comments: EXISTING CONDITIONS WATER SEWER STORM STREET There is an existing l2-inch water main fronting the site in Meadow Ave N. The main is located along the west side of the road. See City asbuilt water drawing W27-0456. Available fire flow exceeds 3,000 gpm. Static pressure in the area is approximately 70 psi. The proposed project is located in the 320 Water Pressure Zone and is outside an AqUIfer Protection Zone. There is an existing 8-inch sewer main fronting the site in Meadow Ave N. There are no storm improvements fronting the site in Meadow Ave N. There is no sidewalk, curb, and gutter fronting the site in Meadow Ave N. CODE REOUIREMENTS WATER 1. Water System Development Charges are based on a rate of $1,956 per new single-family lot. Fees based on the site plan are $1,956.00. Credit is given for the existing home. Payment of this fee is required prior to issuance of utility construction permit. 2. Fire flow requirement for single-family residences is 1,000 gpm. A hydrant is required within 300 feet of the furthest stru<:ture. If new residences exceed 3,600 square feet (including garage), fire flow increases to 1,500 gpm and two hydrants will be required. 3. Any existing hydrant counted as fire protection will require installation of a "storz" quick disconnect fitting if not already in place. It appears an existing hydrant at the comer of N. 36'h and Meadow may be within 300 feet. The engineer is required to show location of all existing hydrants. A new hydrant may be required. 4. All short plats shall provide a separate water service stub to each building lot prior to recording of the plat. Separate permits for water meters will be required. SANITARY SEWER 1. Sanitary Sewer System Development Charges are based on a rate of $1,017.00 per new single-family lot. Total sewer fees based On the site plan are $1,017.00. Credit is given for the existing home if connected to sewer. Payment of this fee is required prior to issuance of utility construction permit. 2. Separate sewer stubs are required to be provided to each new lot prior to recording of the short plat. Teets Shl)r! Plat Page 2 of 2 Septembt:r 24, 2007 3. MInimum slope for side sewers shall be 2%. Dual side sewers are not allowed. SURFACE WATER 1. The Surface Water System Development Charges are based on a rate of $759.00 per new single-family lot. Estimated fces based on the site plan is $759.00. Payment of this fee is required prior to issuance of utility construction permit. 2. Roof drains shall be tightlined to the storm system whenever feasible. Infiltration trenches are allowed if soils are acceptable. 3. A conceptual drainage plan and narrative is required. This project is exempt from detention and water quality per the 1990 KCSWM. 4. A temporary erosion control plan will be required and shall be installed and maintained to the satisfaction of the representative of the Development Services Division for the duration of the project. TRANSPORT A TlON I. Half street improvements including sidewalk, curb, and gutter, paving and storm drainage are required to be installed fronting the site in Meadow Ave N. Applicant may submit a request to Public Works to pay a fee in lieu of installing these improvements. 2. Applicant will be required to dedicate five feet of right-of-way fronting the site in Meadow Ave N. Existing right of way width is 40 feet. Minimum right of way width is fifty feet. It is shown on the plans. 3. Street lighting is not required for a two lot short plat 4. Applicant will be required to comply with the City of Renton's Trench Restoration and Street Overlay Requirements. 5. A traffic control plan, approved by the City will be required for any construction impacting the City's right of way. 6. Maximum driveway slope is 15%. MISCELLANEOUS 1. Separate permits and fees for side sewer connections, water meters, and storm drainage connections are required. 2. Applicant shall he responsible for securing all necessary easements for utilities. 3. Proposed new rockeries or retaining walls to be constructed that are greater than four feet in height (from bottom of footing to top of wall) will be require a separate building permit for structural review. A geotechnical report is required with the submittal. 4. All wire utilities shall be installed underground per the City of Renton Under Grounding Ordinance. If three or more poles are required to be moved by the development design, all existing overhead utilities shall be placed underground. RECOMMENDED CONDITIONS 1. Traffic mitigation fee for each new single-family residence is $717.75. The rate is based on 9.57 trips x $75 x I new lot. Total fee is $717.75. This is payable prior to recording of the short plat. 2. Staff recommends a condition to require this project to design and comply with Department of Ecology's Erosion and Sediment Control Requirements as outlined in Volume II of the 200 I Stormwater Management Manual. cc: Kayren Kittrick PROPERTY SF ICES FEE REVIEW FOR SUBDIVISIOI o. 2007 --"4=<)~~~ RECEIVED FROM (date) JOB ADDRESS:.---aa.JJi~J\,I~~__ ___ WO#'1~_oa. ___ ~ __ ._. _____ _ NATURE OF WORK: C-Lc:!j" :">HOBT PI ~ I SE-j '8~BL:~L~r:l__ LND #. eo -0499 _ .___ __ X PRELIMINARY REVIEW OF SUBDIVISION Y LONG PLAT. NEED Mc)RE INFORMATION: .. LEGAL DESCRIPTION SnORT PLAT, BINDING SITE PLAN, ETC. PID #'s VICINITY MAP FINAL REVIEW OF SUBDIVISION, THIS REVIEW REPLACES SQUARE FOOTAGE OTHER PRELIMINARY FEE REVIEW DATED FRONT FOOTAGE SUBJECT PROPERTY PARENT PID#.a~'70·0Gq X NEW KING CO. TAX ACCT.#(s) are required when assigned by King County. I[ is the iotem of this development fce analysis to put the developer/owner on notice, that the fees Quoted below may be applicable to the subject site upon development of the property. All quoted fees are potential charges that may he due and payable at the time the construction permit is issued to install the on~site and off-site improvemeJlt.~ (i.e. underground utilities. street improvements. etc.) Triggering mechanisms for the SDC fees will be based on current City ordinances and determined by the applicable Utility Section. Please note that these fees are subject to change without notice. Final fees will be based on rates in effect at time of Building Permi[/Construction Permit application. The existing house on SP Lot # ___ , addressed as has not previously paid ---;-,---:-:~ SDC fees, due to connection to City utilities prior to existance of SDC fee Ord. SP Lot# will be SUbject to future SDC fees if triggering mechanisms are touched within current City Ordinances. We understand that this subdivision is in the preliminary stage and that we will have the opportunity to review it again before recordation. The following quoted fees do NOT include inspection fees, side sewer permits, r/w permit fees or the cost of water meters. SPECIAL ASSESSMENT DISTRICT PARCEL METHOD OF ASSESSMENT ASSESSMENT DISTRICTS NO. NO. ASSESSMENT UNITS OR FEE Latecomer Agreement (pvt) WATER -0- Latecomer Agreement (pvt) W ASTEW ATER -0 Latecomer Agreement (pvt) OTHER -0- L Special Assessment District/WATER /-0- / / Special Assessment District/W ASTEW ATER /-0 Joint Use Agreement (METRO) - Local Improvement District • - Traffic Benefit Zones $75.00 PER TRIP, CALCULATED BY TRANSPORTATION - FUTURE OBLIGATIONS - SYSTEM DEVELOPMENT CHARGE -WATER .. Estimated # OF UNITSI SOC FEE Pd Prevo .. PartiaHy I'd (Ltd Exemption) .. Never Pd SQ.FTG. Single familv residential $1,956/unit x .i $I,q,56.ot Mobile home dweHing unit $1,956/unit in park Apartment, Condo $1,174/unit not in CD or COR zones x Commercial/Industrial, $0.273/sq. ft. of property (not less than $1,956.00) x Boeing, by Special Agreemenu'Footprint of Bldg plus 15 ft perimeter (2,800 aPM threshold) SYSTEM DEVELOPMENT CHARGE -W ASTEW ATER" Estimated Pd Prevo .. PartiaHy I'd (Ltd Exemption) Never Pd Single family residential $1,017/unit x \. ~ 1017.00 Mobile home dwelling unit $1,017/unit x Apartment, Condo S610/unit not in CD or COR zones x Commercial/Industrial $0.142/sq. ft. of property x(not less than $1,017.00) SYSTEM DEVELOPMENT CHARGE -SURFACEWATER .. Estimated -. Pd Prevo .. Partially I'd (Ltd Exemption) Never Pd Single family residential and mobile home dwelliol!: unit $759/unit x ~ III 75Q.OO AH other properties $O.265/sq ft of new impervious area of property x (not less than $759.00) I PRELIMINARY TOTAL $ :=I . .,p, P IV" ,,)\1 Jt-r, ,'" ) a . (. 1, F .nnf.k ) ... 9~ '" '" • 0 • " 0 Signat';~~ Revi{jing Authority 0 TE ..., , . -" ±: • *If subject property hi within an LID, it is developers responsibility to check with the Finance Dept. for paid/un-paid status . < ". _. Square footage figures are taken from the King County Assessor! s map and are subject to change. • • .. Current City SOC fee charges apply to 0 0 EFFECTIVE January 2, 2006 City a nton Department of Planning! Building! Pu Vorks ENVIRONMENTAL & DEVELOPMENT APPLICATION REVIEW SHEET REVIEWING DEPARTMENT: Pir:tn h7vIP W COMMENTS DUE: OCTOBER 5, 2007 APPLICATION NO: LUA07-101, SHPL-A DATE CIRCULATED: SEPTEMBER 21, 2007 f~ """'"'" .f" APPLICANT: Darcey Teets PROJECT MANAGER: Andrea Petzel PROJECT TITLE: Teets Short Plat PLAN REVIEW: Jan lilian :;EP 2/ Inm SITE AREA: 12,151 square feet BUILDING AREA (qross): N!A 81111 I'll .. " .. LOCATION: 3612 Meadow Avenue N WORK ORDER NO: 77808 SUMMARY OF PROPOSAL: Application for administrative short plat approval for a 2-lot subdivision in the R-8 zone. Density would be 7.5 dwelling units!acre. The existing home would be demolished. Proposed lot sizes would be 5,880 sq. ft and 5,733 sq. ft. Both new lots would have direct access to Meadow Ave. N via private driveways. There are two significant trees onsite, and no critical areas are present. A. ENVIRONMENTAL IMPACT (e,g, Non-Code) COMMENTS Element of the Probable Probable More Element of the Probable Probable More Environment Minor Major Information Impacts Impacts Necessary Environment Minor Major Information Impacts Impacts Necessary Earth Housin Air Aesthetics Water LighrlGlare Plants Recreation Land/Shoreline Use Utilities Animals Transportation Environmental Health Public SelVices Energy! Historic/Cultural Natural Resources Preservation Airport Environment 10,000 Feet 14,000 Feet B. POLICY-RELATED COMMENTS C, CODE-RELA TED COMMENTS We have reviewed this application with particular attention to those areas in which we have expertise and have identified areas of probable impact or areas where addW I information is needed to properly assess this proposal. sentative Date Kayr~n Kittrick -Transportation Mitigation Fee,doc I Project Name: Project Address: Contact Person: Permit Number: Project Description: Land Use Type: ~esidential o Retail o Non-retail Calculation: S# -nq Transportation Mitigation Fee Method of Calculation: ~E Trip Generation Manual, 7th Edition o Traffic Study oOther (~'O)5FR.. q.S7loLL ~-I \y...9.57 APT ~.-:n 'I.. $15 _dl-'ll.iS Transportation Mitigation Fee: Calculated by: eU'n.15 . \'.l:!\!'4o Date: , Date of Payment: ______________________________________________ ___ Page 1 City 0 nton Department of Planning! Building! Pu Vorks ENVIRONMENTAL & DEVELOPMENT APPLICATION REVIEW SHEET REVIEWING DEPARTMENT: EC"Y){l'Y); r 'I]:>,V'. COMMENTS DUE: OCTOBER 5, 2007 APPLICATION NO: LUA07-101, SHPL-A DATE CIRCULATED: SEPTEMBER 21,2007 APPLICANT: Darcey Teets PROJECT MANAGER: Andrea Petzel PROJECT TITLE: Teets Short Plat PLAN REVIEW: Jan lilian SITE AREA: 12,151 square feet BUILDING AREA (gross): NIA LOCATION: 3612 Meadow Avenue N I WORK ORDER NO: 77808 SUMMARY OF PROPOSAL: Application for administrative short plat approval for a 2-lot subdivision in the R-8 zone. Density would be 7.5 dwelling units/acre. The existing home would be demolished. Proposed lot sizes would be 5,880 sq. ft. and 5,733 sq. ft. Both new lots would have direct access to Meadow Ave. N via private driveways. There are two significant trees ansite, and no critical areas are present. A, ENVIRONMENTAL IMPACT (e.g. Non-Code) COMMENTS Element of the Probable Probable More Element of the Probable Probable More Environment Minor Major Information Environment Minor Major Information Impacts Impacts Necessary Impacts Impacts Necessary Earth Hou,ing Air Water Plants Land/Shoreline Use Animals ~ Environmental Health Energy/ Natura! Resources Arf~r~::: B. POLICY-RELA TED COMMENTS C. CODE-RELA TED COMMENTS We have reviewed this application with particular attention to those areas in which we have expertise and have identified areas of probable impact or areas where additional information is needed JO !:jper/y asse~s this proposal. ;tRY> /)Cr .J~';t4 :'7< ;3(?() 7 ~S~ig-n-at~u-re-o~f~D~ir-e-ct~o-r-or-A~u~t~ho-r~iz-e~d~R~e-p-ref~~en~t-at~iv~e~--~---------------Date I City 0 nton Department of Planning I Building I Pu Vorks ENVIRONMENTAL & DEVELOPMENT APPLICATION REVIEW SHEET REVIEWING DEPARTMENT: CDrl'\tnl ctiOtl COMMENTS DUE: OCTOBER 5, 2007 APPLICATION NO: LUA07-1 01, SHPL-A DATE CIRCULATED: SEPTEMBER 21,2007 APPLICANT: Darcey Teets PROJECT MANAGER: Andrea Petzel PROJECT TITLE: Teets Short Plat PLAN REVIEW: Jan lilian RECEIVED SITE AREA: 12,151 square feet BUILDING AREA (qross): N/A SEP 2 f 1rln., LOCATION: 3612 Meadow Avenue N WORK ORDER NO: 77808 SUMMARY OF PROPOSAL: Application for administrative short plat approval for a 2-lot subdivision in the R-8 zone. De~~:t;,v":''o'~fd be 7.5 dwelling units/acre. The existing home would be demolished. Proposed lot sizes would be 5,880 sq. ft. and 5,733 sq. ft. Both new lots would have direct access to Meadow Ave. N via private driveways. There are two significant trees onsite, and no critical areas are present. A. ENVIRONMENTAL IMPACT (e.g. Non-Code) COMMENTS Element of the Probable Probable More Element of the Probable Probable More Environment Minor Major Information Environment Mjnor Major Information Impacts Impacts Necessary Impacts Impacts Necessary Earth Housin Air Aesthetics Water Light/Glare Plants Recreation Land/Shoreline Use Utilities Animals Transportation Environmental Health Public Services Energy/ Historic/Cultural Natural Resources Preservation Airport Environment 10,000 Feet 14,000 Feet B. POLICY-RELA TED COMMENTS C. CODE-RELA TED COMMENTS We have reviewed this application with particular attention to those areas in which we have expertise and have identified areas of probable impact or areas wh (e additional information is needeg to properly assess this proposal. " , Date September 21, 2007 Michael Fortson Department of Transportation Renton School District 1220 N 4th Street Renton, W A 98055 Subject: Teets Short Plat LUA07-101, SHPL-A CITY .F RENTON Planning/Building/Public Works Department Gregg Zimmerman P.E., Administrator JEVELOPMENT PLANNING CITY OF RENTON OCT -! 2007 RE::CEIVED The City o~· Renton Dcve!o~~m1cnt Ser'\.:iccs Division has pc'ceived an application for a 2-lot single-family subdivision located at 3612 Meadow Avenue N. Please see the enclosed Notice of Application for further details. In order to process this application, the Development Services Division needs to know which Renton schools would be attended by children living in residences at the location indicated above. Please fill in the appropriate schools on the list below and return this letter to my attention, Development Services Division, City of Renton, 1055 South Grady Way, Renton, Washington 98057 by October 5, 2007. V· .' Elementary School: ---F!-,=.Lf",IL1'L:i I...:.:",Lt\ (,-:"",Ike .... ! ""l""t:=' ~ __________________ _ Middle School: --~IR\'-1':( L-"",,:,,-,-t~ll-L1 "-"l)~l<....l\,--,-r ______________ _ High School: ____ ~II-·~.c; . ..JirL.--;'"''"''''b''-~:N'-'"-· __________________ _ Will the schools you have indicated be able to handle t~mpact of the additional students estimated to come from the proposed development? Yes . No. __ _ Any Comments: _______________________________ _ Thank you for providing this important infonnation. If you have any questions regarding this project, please contact me at (425) 430·7270. Sincerely, / [j{~~t4( Andrea Petzel Associate Planner Encl. -------l-OS-S-s-o-u-th-G-r-ad-y-W-a-y-.-R-e-nt-on-,-w-a-s-hi-ng-t-on-9-80-S-7-------------~ ® ThiS paper cor.ta:ns 5U'/0 recyc'ed rnatenal, ::>O~/o po,,! c,m<;urTT-r ~fll'_:\1J OF Till'. (;CRVJ'. CITY OF RENTON CURRENT PLANNING DIVISION AFFIDAVIT OF SERVICE BY MAILING On the 21 st day of September, 2007, I deposited in the mails of the United States, a sealed envelope containing Acceptance Letter & NOA documents. This information was sent to: Name Joe Hopper Denney & Robin Teets Doris J. Pease Darcey Teets Surrounding Property Owners (Signature of Sender): y--~ STATE OF WASHINGTON ) ) SS COUNTY OF KING ) Contact Owners Owner Applicant See Attached I certify that I know or have satisfactory evidence that Stacy Tucker Representing signed this instrument and acknowledged it to be his/her/their free and voluntary act for the uses and purposes mentioned in the instrument. Dated: 5' / d Yln"1 • Notary (Print):--k::Ln::~~::--=~..t:lJ:::::""-J::i.JU~mSiJ.L-J;;.~'--'~~-----,k.-E My appointment expires: Cl -I q -l 0 Project Name: Teets Short Plat Project Number: LUA07-1 01, SHPL-A 334270048906 BAKER JAMES C 3713 MEADOW AVE N RENTON WA 98056 334270046702 CHAU DAVID TRUNG & PING LU 1426 N 36TH ST RENTON WA 98056 334270048401 DUNDAS DONALD R & P DENICE 3701 MEADOW AVE N RENTON WA 98056 334270049706 JEPSON BARRY+ANITA 11642 100TH AVE NE #105 KIRKLAND WA 98034 334270062709 LAKE BUCKY L 3716 MEADOW AVE N RENTON WA 98056 334270047205 MATTHEWS SYLVIA B 3609 MEADOW AVE N RENTON WA 98056 334270049409 MOFFATT ROBERT L & JOAN L 3709 MEADOW AVE N RENTON WA 98056 334270061305 STARBOW BUILDERS 2004 NE 28TH PL RENTON WA 98056 334270061701 TEETS DENNY J+ROBIN D+PEASE 3612 MEADOW AVE N RENTON WA 98056 334270048609 BROWNE THEO A+KIMBERLY A 1409 N 37TH ST RENTON WA 98056 334270062501 DENEAU ALEA 116 14TH AVE E #1 SEATTLE WA 98112 334210314301 HUNTER DAVID A+KATHLEEN A 1425 N 36TH ST RENTON WA 98056 334210314806 JIM JACQUES CONSTRUCTiON 1216 NE 38TH ST RENTON WA 98056 334270049201 LIANG GUOXUAN+XUELING LUO ET AL 3705 MEADOW AVE N RENTON WA 98905 334270061503 MEADOW2 LLC 4230 160TH AVE SE BELLEVUE WA 98006 334210314905 RAMOS PEPE R+CATON DEBORAH 1429 N 36TH ST RENTON WA 98056 334270050001 STOLLER SHAWN E+LYNN E 1405 N 38TH ST RENTON WA 98056 334270061008 UNG WENDY+SASSI SAID 3600 MEADOW AVE N RENTON WA 98056 334270046603 BUDD JAMES H 1402 N 36TH RENTON WA 98056 334270048203 DUESENBERG ERIKA l+JONES MA 1403 N 37TH PL RENTON WA 98056 334270047601 JENKINS ERIK M+KIMBERLY A 3611 MEADOW AVE N RENTON WA 98056 334270048104 KILLIAN ANN PATRICIA 3615 MEADOW AVE N RENTON WA 98056 334270062006 MARTIN DANA RENNELLE+CANTEL 3704 MEADOW AVE N RENTON WA 98056 334270048005 MITCHELL G C 3625 MEADOW AVE N RENTON WA 98055 334270047304 SAUNDERS AMY L 3605 MEADOW AVE N RENTON WA 98056 334270063004 TASCA JAMES G 14805 SE JONES PL RENTON WA 98058 334210315100 ZHENG TONG LI+MINNA 1433 N 36TH RENTON WA 98056 NOTICE OF APPLICATION A Master Application has been filed and accepted with th .. Development Services Division of the City of Renton. Ttle following briefly doscribes tho application and the n"c~5sary Public Approvals. PROJECT NAME/NUMBER: Teels 31101 Plat.' UJA07-iQl, SHPL·A PROJECT DESCRIPTION: A;:.pllc~tlon fer aominlstratlvB slWrl pial approval tor a 2-101 subdiVISiOn In tnc. R-8 zena. Dens,t\' would be 7 5 dwel:ing units/acre The eXisting nome would be demolished Prcposed lot sizes wou,d be 5.BBO sC.' ft. an~ 5.733 sq II Bot!-new lots would have dlree: access to Meadow Ave N VIa o,,',ale oflveways There are two Significant tree5 onslte, and no c"llc~1 areas are present PROJECT LOCATION: 3612 Meadow Avenue N PUBLIC APPROVALS; Admlnistrallve Shan Pial APPLICANTIPROJECT CONTACT PERSON Joe Hopper, P.E PaCific E191neenrg Deslgn LLC, To;l (206) 431_7870; Eml Jhopper@pacengco'11 Comments on tho aboYo application must be 5ubmltted In writing to Andrea Petzel, Associate PI~nner, Development Services Division, 1055 South Grady Way, R"nton, WA 9&057, by 5:00 PM on October 5, 2007, II you have que~tlons about this proposal. or WISh to be made" p"rty of reoord and r6{:e,ve Mclitlonal notillcat,on b)" mail, contact the PrOject Manager at (425', 430-727C. Anyone who suomlts wr:\ten comments will automaticaily become a party of record ~~d Will be not,\<sd 01 a~y decision on this project PLEASE INCLUDE THE PROJECT NUMBER WHEN CALLING FOR PROPER FILE IDENTIFICATION DATE OF APPLICATION: September 11, 2007 NOTICE OF COMPLETE APPLICATION: September 21, 2007 DATE OF NOTICE OF APPLICATION: September 21, 2007 If yOU WO'Jld like to be made a party of record to recel¥e further Informalion on Ihls proposed project, complete thIS form and return to: City 01 Rentor., Development Pla~n.ng, 1055 Soulh Grady Way, Ranton, WA 98057 Flte Name I No.: Tao;ls Short Plat I LUA07-101, SHPL-A ";WE MAlLtNGADDRES$ ______________________ _ TELEPHONE NO CERTIFICATION I, {;( Vi OJfq '&, , hereby certify that _-:;=-_ were posted by me in ~ conspicuous places or nearb A TrEST: Subscribed and sworn before me, a Notary Public, in and for the State of Washington residing ~~ \>-\-\-e. , on the daYOf~~ NOTICE OF APPLICATION A Master Application has been filed and accepted with the Development Services Division of the City of Renton. The following briefly describes the application and the necessary Public Approvals. PROJECT NAMEINUMBER: Teets Short Plat! LUA07-101, SHPL-A PROJECT DESCRIPTION: Application for administrative short plat approval for a 2-lot subdivision in the R-8 zone. Density would be 7.5 dwelling units/acre. The existing home would be demolished. Proposed lot sizes would be 5,880 sq. ft. and 5,733 sq. ft. Both new lots would have direct access to Meadow Ave. N. via private driveways. There are two significant trees onsite, and no critical areas are present. PROJECT LOCATION: 3612 Meadow Avenue N PUBLIC APPROVALS: Administrative Short Plat APPLICANT/PROJECT CONTACT PERSON: Joe Hopper, P.E., Pacific Engineering Design, LLC; Tel: (206) 431-7970; Eml: jhopper@pacen9_com Comments on the above application must be submitted in writing to Andrea Petzel, Associate Planner, Development Services Division, 1055 South Grady Way, Renton, WA 98057, by 5:00 PM on October 5,2007. If you have questions about this proposal, or wish to be made a party of record and receive additional notification by mall, contact the Project Manager at (425) 430-7270. Anyone who submits written comments will automatically become a party of record and will be notified of any decision on this project. I PLEASE INCLUDE THE PROJECT NUMBER WHEN CALLING FOR PROPER FILE IDENTIFICATION I DATE OF APPLICATION: NOTICE OF COMPLETE APPLICATION: DATE OF NOTICE OF APPLICATION: September 11, 2007 September 21, 2007 September 21, 2007 If you would like to be made a party of recard to receive further information on this proposed project, complete this form and return to: City of Renton, Development Planning, 1055 South Grady Way, Renton, WA 98057. File Name! No.: Teets Short Plat! LUA07-101, SHPL-A NAME: ______________________________________________________________ ___ MAILING ADDRESS: ______________________________________________________ ___ TELEPHONE NO.: ________________________ _ September 21,2007 Joe Hopper, P.E. Pacific Engineering Design, LLC 15445 53 rd Avenue S #100 Seattle, WA 98188 Subject: Teets Short Plat LUA07-101, SHPLcA Dear Mr. Hopper: CIT') :IF RENTON Planning/Building/Public Works Department Gregg Zimmerman P.E., Administrator The Development Planning Section of the City of Renton has determined that the subject application is complete according to submittal requirements and, therefore, is accepted for review. You will be notified if any additional information is required to continue processing your application. Please contact me at (425) 430-7270 if you have any questions. Sincerely, ~~t4( Associate Planner cc: Denney & Robin Teets, Doris J. Pease I Owners Darcey Teets I Applicant ------------I-O-55-S-o-u-fu-G-rn-d-y-W-a-y---Re-n-to-n-,W--M-hl-'n-gW-n--98-0-57-·~----------~ * This paperCOl"ltains 50% recycled material, 30% postconsumer AHEAD OF THE CURVE 01:.'1-\ej City of Renton 1h\:VIlLOPMENT PLANNINC ,.. CITY OF ,,<'NTON LAND USE PERMIT SEP 11 2007 RECEIVED MASTER APPLICATION PROPERTY OWNER(S) TELEPHONE NUMBER AND E-MAIL ADDRESS: NAME:De..n(\~ "Te.e-+s o..~ fZolo;('.. "'!esh. (206) 431·7970 jhopper@paceng.com ADDRESS: 3 S \-\OI.~6U,J fZ.d PROJECT INFORMATION PROJECT OR DEVELOPMENT NAME: Teets Short Plat CITY: 'Dix \·h\\.s Ni ZIP: 117'-16 TELEPHONE NUMBER: 63/-6b7-q17~ PROJECT/ADDRESS(S)/LOCATION AND ZIP CODE: 3612 Meadow Avenue N., Renton, WA 98056 APPLICANT (if other than owner) KING COUNTY ASSESSOR'S ACCOUNT NUMBER(S): NAME: Darcey Teets 3342700617 COMPANY (if applicable): EXISTING LAND USE(S): Residential Single Family ADDRESS: 2838 109th Ave SE PROPOSED LAND USE(S): Residential Single Family EXISTING COMPREHENSIVE PLAN MAP DESIGNATION: CITY: Bellevue ZIP: 98004 Residential Single Family (RSF) TELEPHONE NUMBER 206·391-1500 PROPOSED COMPREHENSIVE PLAN MAP DESIGNATION (if applicable): Residential Single Family (RSF) CONTACT PERSON EXISTING ZONING: R-8 NAME: Joe Hopper, P.E. PROPOSED ZONING (if applicable): R·8 COMPANY (if applicable): Pacific Engineering Design, LLC SITE AREA (in square feet): 12,151 sq ft or .28 acres SQUARE FOOTAGE OF PUBLIC ROADWAYS TO BE ADDRESS: 15445 53'd Avenue 5., Suite 100 DEDICATED: 539 sq ft SQUARE FOOTAGE OF PRIVATE ACCESS EASEMENTS: CITY: Seattle ZIP: 98188 NfA PROPOSED RESIDENTIAL DENSITY IN UNITS PER NET ACRE (if applicable): 2 lots = net density of 7.5 DU per acre Q:web/pw/devserv/fonnsiplatulingimasterapp.doc 08/03107 PR ECT INFORMATION conti I NUMBER OF PROPOSED LOTS (if applicable): 2 NUMBER OF EMPLOYEES TO BE EMPLOYED BY THE NEW PROJECT (if applicable): N/A NUMBER OF NEW DWELLING UNITS (if applicable): 2 PROJECT VALUE: IS THE SITE LOCATED IN ANY TYPE OF NUMBER OF EXISTING DWELLING UNITS (if applicable): 1 ENVIRONMENTALLY CRITICAL AREA, PLEASE INCLUDE house will be demolished SQUARE FOOTAGE (if applicable): N/A SQUARE FOOTAGE OF PROPOSED RESIDENTIAL o AQUIFER PROTECTION AREA ONE BUILDINGS (if applicable): o AQUIFER PROTECTION AREA TWO SQUARE FOOTAGE OF EXISTING RESIDENTIAL BUILDINGS TO REMAIN (if applicable): N/A o FLOOD HAZARD AREA sq. ft. SQUARE FOOTAGE OF PROPOSED NON-RESIDENTIAL o GEOLOGIC HAZARD sq. ft. BUILDINGS (if applicable): N/A o HABITAT CONSERVATION sq. ft. SQUARE FOOTAGE OF EXISTING NON-RESIDENTIAL o SHORELINE STREAMS AND LAKES sq. ft. BUILDINGS TO REMAIN (if applicable): N/A NET FLOOR AREA OF NON-RESIDENTIAL BUILDINGS (if 0 WETLANDS sq. ft. applicable): N/A LEGAL DESCRIPTION OF PROPERTY (Attach legal description on separate sheet with the following information included) SITUATE IN A PORTION OF THE S.E. y., NW. Y. OF SECTION 32, TOWNSHIP 24 N., RANGE 5E, IN THE CITY OF RENTON, KING COUNTY, WASHINGTON. TYPE OF APPLICATION & FEES List all land use applications being applied for: 1. Short Plat 3. 2. 4. Staff will calculate applicable fees and postage: $ AFFIDAVIT OF OWNERSHIP I. (Print Name/s) ~{lf1fgf Teels q!!d RohlfL ~f~ ,declare that I am (please check one) ~he current owner of the property involved in this application __ the authorized representative to act for a corporation (please attach proof of authorization) and that the foregoing statements and answers herein contained and the information herewith are in all respects true and correct to the best of my knowledge and belief. I certify that r know or have satisfactory evidence that le.ets ,b' .-~ ~. .::::.:t signed this instrument and acknowledged it to be hislhe their e and voluntary act for the uses and purposes mentioned in the instrument. (Signature of Owner/Representative) Notary pu~c in and for the State of W:~h:9h,H .1JeM.; '01:1'. (Signature of Owner/Representative) .~ / ( 2 rl,{ n f2t Li'lu f( LL.i E\JZADETH taHt~O:;~~~orIi Notary (Print) LC. ALL.' 'C ~ NOtal j publIC. Ss\i1_ . No. o\1·\A eoontY t I I · Ooallflod In N'a .. ad I 1i5 2ll.li '.' 7 I ,,-t ( I tomm1soIon llx\>1f8' Ju Y • My appointment expires:_J_-t-'_-,J'-!-_-'.L. ____ _ I Q:web/pw/devserv/fonns/pialUling/masterapp.doc 2 08/03/07 City of Renton DEVELOPMENT PLANNING CITY OF RFNTON LAND USE PERMIT SEP 1 1 2007 RECE!VED MASTER APPLICATION PROPERTY OWNER(S) TELEPHONE NUMBER AND E·MAIL ADDRESS: NAME:&. ~ ~4.<l e..-./. k _ p (206) 431-7970 jhopper@paceng.com PROJECT INFORMATION ADDRESS: I/, ~t7S-o .-9 r:..2/ PROJECT OR DEVELOPMENT NAME: Teets Short Plat C~ u)"" ZIP: 9 9' t:? t:? s;> PROJECT/ADDRESS(S)/LOCATION AND ZIP CODE: TELEPHONE NUMBER: 'I...l.J--~-.o:i-'Bg~ 3612 Meadow Avenue N., Renton, WA 98056 APPLICANT (if other than owner) NAME: Darcey Teets KING COUNTY ASSESSOR'S ACCOUNT NUMBER(S): 3342700617 COMPANY (if applicable): EXISTING LAND USE(S): Residential Single Family ADDRESS: 2838 109th Ave SE PROPOSED LAND USE(S): Residential Single Family EXISTING COMPREHENSIVE PLAN MAP DESIGNATION: CITY: Bellevue ZIP: 98004 Residential Single Family (RSF) TELEPHONE NUMBER 206-391-1500 PROPOSED COMPREHENSIVE PLAN MAP DESIGNATION (if applicable): Residential Single Family (RSF) CONTACT PERSON EXISTING ZONING: R-8 NAME: Joe Hopper, P.E. PROPOSED ZONING (if applicable): R-8 COMPANY (if applicable): Pacific Engineering Design, LLC SITE AREA (in square feet): 12,151 sq ft or .28 acres SQUARE FOOTAGE OF PUBLIC ROADWAYS TO BE ADDRESS: 15445 53 rl1 Avenue S., Suite 100 DEDICATED: 539 sq ft SQUARE FOOTAGE OF PRIVATE ACCESS EASEMENTS: CITY: Seattle ZIP: 98188 N/A PROPOSED RESIDENTIAL DENSITY IN UNITS PER NET ACRE (if applicable): 2 lots = net density of 7.5 DU per acre Q:web/pw/devserv/formsJp\anningimasterapp.doc 08122/07 PR -ECT INFORMATION contil d NUMBER OF PROPOSED LOTS (if applicable) 2 NUMBER OF EMPLvYEES TO BE EMPLOYED BY THE NEW PROJECT (if applicable): N/A NUMBER OF NEW DWELLING UNITS (if applicable): 2 PROJECT VALUE: IS THE SITE LOCATED IN ANY TYPE OF NUMBER OF EXISTING DWELLING UNITS (if applicable): 1 ENVIRONMENTALLY CRITICAL AREA, PLEASE INCLUDE house will be demolished SQUARE FOOTAGE (if applicable) N/A SQUARE FOOTAGE OF PROPOSED RESIDENTIAL 0 AQUIFER PROTECTION AREA ONE BUILDINGS (if applicable): o AQUIFER PROTECTION AREA TWO SQUARE FOOTAGE OF EXISTING RESIDENTIAL BUILDINGS TO REMAIN (if applicable): N/A 0 FLOOD HAZARD AREA sq. ft. SQUARE FOOTAGE OF PROPOSED NON-RESIDENTIAL 0 GEOLOGIC HAZARD sq. ft. BUILDINGS (if applicable): N/A 0 HABITAT CONSERVATION sq. ft. SQUARE FOOTAGE OF EXISTING NON-RESIDENTIAL o SHORELINE STREAMS AND LAKES sq. ft. BUILDINGS TO REMAIN (if applicable): N/A NET FLOOR AREA OF NON-RESIDENTIAL BUILDINGS (if 0 WETLANDS sq. ft. applicable): N/A LEGAL DESCRIPTION OF PROPERTY (Attach legal description on separate sheet with the following information included) SITUATE IN A PORTION OF THE S,E. y., N.W. Y. OF SECTION 32, TOWNSHIP 24 N" RANGE 5E, IN THE CITY OF RENTON, KING COUNTY, WASHINGTON, TYPE OF APPLICATION & FEES List all land use applications being applied for: 1, Short Plat 3, 2, 4, Staff will calculate applicable fees and postage: $ AFFIDAVIT OF OWNERSHIP I, (Print Name/s) .[)" Ie. IS J" ?e II-S .,.. , declare that I am (please check one) /the current owner of the property involved in this application or __ the authorized representative to act for a corporation (please attach proof of authorization) and that the foregoing statements and answers herein contained and the information herewith are in alt respects true and correct to the best of my knowledge and belief. (Signature of Owner/Representative) (Signature of Owner/Representative) Q:web/pw/devserv/forms/planninglmasterapp.doc I certify that I know or have satisfactory evidence that IJ::£.IS J. fE!>S E signed this instrument and acknowledged it to be his/her/their free and voluntary act for the uses and purposes mentioned in the instrument. . 2 08/22/07 PACIFlc.E:r\lGINEERING DESIGN) LLC:=· = CIVIL ENGINEERING AND PLANNING CONSULTANTS September 4, 2007 Ms. Andrea Petzel City of Renton Development Services Division 1055 South Grady Way Renton, W A 98055 Subject: Teets Short Plat Project Narrative Dear Andrea: DEVELOPMENT PLANNING CITY OF RENTON SEP 1 1 2007 RECE!VED PED Project No.: 06089 On behalf of our client, Darcey Teets, the following is the Project Narrative for the Teets Short Plat, as required as part of the City of Renton Short Plat submittal checklist. • Project Name, Size and Location: The Teets Short Plat is located in Section 35, Township 24, Range 5E, W.M. in the City of Renton. The site is located in Hillmans Lake Washington Garden of Eden No.2, plat lot 122. The King County Parcel number is 3342700617. The site is more specifically at 3612 Meadow Avenue North, located north of the intersection of Meadow Avenue No' :lndt,J. 36th St., on the east sid&*Meadow Avenue N. The existing lot size is'1'~ sq ft, which also equals . ~ acres. The site currently contains a single family residence which will be removed. This project proposes to subdivide the existing lot into two lots with two new single family residences. • Land Use Permits required: Preliminary and Final Short Plat Approvals, Construction Drawing Approval. • Zoning Designation: The property is zoned Residential R-8. The adjacent properties are single family residential. • Current Use: There is an existing single family residence on site which will be removed. • Special Features: There is rio indication of wetlands or streams on site. There are no steep slopes on site. However, since there is an existing retaining wall and a significant grade change between proposed Lots 1 and 2, the city required a Geotechnical Engineering Study be prepared. Copies of the Geotechnical Engineering Study, prepared by Geotech Consultants on July 27, 2007 are inel uded with this submittal. www.paceng.com -! 15445 53RD AVENUE SOUTH, SUITE 1 o:::J,SEATTLE, WA 881 aa FAX 206388-1648 PHONE 425 251-8811 206431-7870 .. Ms. Andrea PetLel City of Renton September 4,2007 Teets Short Plat • Soil Type/Drainage: According to the Geotechnical Engineering Study prepared by Geotech Consultants, dated July 27, 2007, "The test pits for this study encountered loose-native and fill soils down to approximately 3 to 7 feet below the ground surface. Native, loose to medium-dense sand was revealed below the loose soiL" The proposed project's stoml water will be discharged to the drainage system lying within Meadow Avenue along the frontage of the property, Detention and water quality are not proposed for this project. • Proposed Use: Two new single-family residences are proposed. • Access: Access to the project will be from Meadow Avenue N, • Easement: There is an ingress/egress easement (Recording #9312102007) for access to a garage for the benefit of the parcel adjacent to the south of this project. The garage was at some point removed. This ingress/egress easement is currently shown on the short plat plans; however, since fue garage is no longer on the site, this easement will be relinquished and will then be removed from the plans, • Proposed off-site improvements: No off-site improvements are proposed, The applicant is requesting to pay a fee-in-lieu of constructing frontage improvements. • Total Estimated Cost/Fair Market Value: Estimated cost $500,000; Market value (completed homes) $600,000, • Estimated cut and fill quantities: 400 cy cut, 400 cy filL • Tree Removal: No significant tree removal is anticipated for home construction on this site, • Dedication to the City: A 5 foot right-of-way dedication is proposed along the frontage of the property, for an approximate area of 540 square feet. • Proposed size, nnmber and range: Proposed lots are approximately 5,947, sq ft, • Job shacks, sales trailers, and model home: No proposal at this time, • Any proposed modifications being requested: None. Pacific Engineering Design LLC Page 2 of3 P:IProject Filesl06089 Teets Short PlatlProject Narrative for Short Plat SubmittaL doc Ms. Andrea Petzel City of Renton September 4, 2007 Tcets Short Plat If you have any questions or concerns, please contact me at (206) 431-7970 or via email at jhopper(a1paceng.coll1. Sincerely, ivd . oe Hopper Project Manager cc: Darcey Teets Pacific Engineering Design LLC P:IProject Filesl06089 Teets Short PlatlProject Narrative for Short Plat Submittal.doc Page 3 of3 • Pre-application meeting forr the TEETS SHORT PLAT 3612 Meadow Avenue, N. PRE01-012 City of Renton Development Services Division March I, 2001 Contact information Planner: Andrea Petzel (425) 430-7270 Public Works Plan Reviewer: Jan lilian (425) 430-7216 Fire Prevention Reviewer: James Gray (425) 430-7023 Building Department Reviewer: Craig Burnell, (425) 430-7290 DEVELOPMENT PLANNING CITY OF RENTON ' SEP t 1 2007 RECEIVED Please retain this packet throughout the course of your project as a reference. Consider giving copies of it to any engineers, architects and contractors who work on the project. Pre-screening: When you have the project ready for submittal, have it pre-screened before making all of the required copies. The pre-application meeting is informal and non-binding. The comments provided on the proposal are based on the codes and policies in effect at the time of review. The applicant is cautioned that the development regulations are amended at times, and the proposal will be formally reviewed under the regulations in effect at the time of formal project submittal. The information contained in this summary is subject to modification and/or concurrence by official decision-makers (e.g., Hearing Examiner, Zoning Administrator, Public Works Administrator, and City Council). DATE: TO: FROM: SUBJECT: FIRE DEPARTMENT MEMORANDUM February 20, 2007 Andrea Petzel, Associate Planner James Gray, Assistant Fire Marshafl ~ )J Teets Short Plat, Meadow Ave N lt36th St Fire Department Comments: I. A fire hydrant with 1000 GPM fire flow is required within 300 feet of all new single- family structures. If the building square footage exceeds 3600 -square feet in area, the minimum fire flow increases to 1500 GPM and requires two hydrants within 300 feet of the structure. 2. A fire mitigation fee of$488.00 is required for all new single-family structures. Please feel free to contact rue if you have any questions. i;\teetssp.doc TO: FROM: DATE: Andrea Petzel Jan Illian February 26, 2007 CITY OF RENTOl'l MEMO PUBLIC WORKS SUBJECT: PREAPPLICATON REVIEW COMMENTS TEETS SHORT PLAT PREAPP NO. 07-012 3612 -Meadow Ave N. NOTE ON PRELIMINARY REVIEW COMMENTS CONTAINED IN TIDS REPORT: The following comments on development and permitting issnes are based on the pre-application snbmittals made to the City of Renton by the applicant. The applicant is cautioned that information contained in this summary may be subject to modification and/or concurrence by official decision makers (e.g. Hearing Examiner, Boards of Adjustment, Board of Public Works and City Council). Review comments may also need to be revised based on site planning and other design changes required by the City or made by the applicant. WATER 1. There is an existing 12-inch water main fronting the site in Meadow Ave. The main is on the west side of the road. Available fIre flow exceeds 3,000 gpm. Static pressure in the area is approximately 70 psi. 2. All new construction must have a fIre hydrant capable of delivering a minimum of 1,000 gpm and must be located within 300 feet of the structures. There is a fire hydrant in the vicinity that may be counted towards the fire protection of this project, but is subject to verification for being within 300 feet of the nearest comer of the building. t('leolfIT<.v0/ >.~ U,.",,,";;:L..'fW" 3. Existing hydrant(s) to be counted as fire protection will require a 5" storz quick disconnect fitting to be installed if not already in place. . 4. The proposed project is located in the 320 Water Pressure Zone and outside an Aquifer Protection Zone. 5. The Water System Development Charge is $1,956.00 per new single-family lot. Credit will be given to the existing home. This is payable at the time the utility construction permit is issued. 6. All short plats shall provide a separate water service to each building lot prior to recording of the short plat. SANITARY SEWER I. There is an existmg 8-inch sewer main in Meadow Ave N. 2. Short plats shall provide a separate side sewer stubs to new building lot prior to recording of the short plat. No dual side sewers are allowed. Side sewer shall be a minimum of 2% grade. 3. The Sanitary Sewer System Development Charge is $1,017.00 per new single-family lot. Credit will be given for the existing home. This is payable at the time the utility construction permit is issued. Teets Short Plat Preapplication February 26, 2007 Page 2 of2 SURFACE WATER I. A preliminary drainage plan and drainage narrative will be required for the site plan application. This site is required to comply with the 1990 KCSWM. 2. The Surface Water System Development Charge is $759.00 per new building lot. Credit wiJI be given for existing home. This is payable at the time the utility construction pennit is issued. 3. Erosion control shall comply with the latest edition of the Department of Ecology's Storrowater Manual. TRANSPORTATION I. Street lighting is not required to be installed for 3 lots or less. 2. Applicant will be required to dedicate five feet of right-of-way fronting the site in Meadow Ave N. Minimum right of way width is fifty feet. 3. The traffic mitigation fee of $75 per additional generated trip shall be assessed per new single family home at a rate of9.57 trips. ($75 x 9.57 x # oflots). Credit will be given to existing home. ~l \1 4. Half street improvements including sidewalk, curb, gutter, paving and storro drainage are required to be installed if not already in place per City code. Applicant may submit a request to Public Works to pay a fee in lieu of installing these improvements. ~ w.l U:.J APfUcM..\j.... ~ S; L;1c!. 5. All wire utilities shall be installed underground per the City of Renton Undergrounding Ordinance. If three or more poles are required to be moved by the development design, all existing overhead utilities shaH be placed underground. GENERAL COMMENTS I. All plans shaH conforro to the Renton Drafting Standards 2 Wben approval of preliminary plat is granted and utility plans are complete, please submit permit application, three (3) copies of drawings, two (2) copies of the drainage report, and an itemized cost of construction estimate and application fee at the counter on the sixth floor. A fee worksheet is attached for your use, but prior to preparing a check, it is recommended to caH 425-430-7266 for a fee estimate as generated by the permit system. The fee for review and inspection of these improvements is 5% of the first $100,000 of the estimated construction costs; 4% of anything over $100,000 but less than $200,000, and 3% of anything over $200,000. Halfthe fee must be paid upon application. 3. The applicant is responsible for securing all necessary private utility easements prior to the recording of the short plat. 4. Separate permits and fees for water meters, side sewers, and storro drainage connections are required. cc: Kayren Kittrick DATE: TO: FROM: SUBJECT: General CHY OF RENTON JI>i:mning/BuHding/JPubiic Woriks MEMORANDUM March 1, 2007 Pre-Application File No. PRE07-012 Andrea Petzel, Planner (425) 430-7270 Teets Short Plat We have completed a preliminary review of the pre-application for the above-referenced development proposal. The following comments on development and permitting issues are based on the pre-application submittals made to the City of Renton by the applicant and the codes in effect on the date of review. The applicant is cautioned that information contained in this summary may be subject to modification and/or concurrence by official decision-makers (e.g., Hearing Examiner, Zoning Administrator, Development Services Director, Public Works Administrator, and City Council). Review comments may also need to be revised hased on site planning and other design changes required by City staff or made by the applicant. The applicant is encouraged to review all applicable sections of the Renton Municipal Code. 1be Development Regulations are available for purchase for $50.00 plus tax, from the Finance Division on the first floor of City Hall or on the City's website www.rentonwa.gov. Project Proposal The subject property is zoned Residential-S (R-S), and is located in the Kennydale Hill area of Renton, at 3612 Meadow Avenue, N. The proposal is to subdivide an approximately 13,827 (.32 acre) parcel into two lots. The site contains one existing house, which would be demolished and two new single-family residences will be built. Proposed lot sizes are approximately 5,947 sq. ft. and both lots would be accessed from Meadow Avenue, N. Development Standards Zoning/Densitv Requirements -The subject property is located within the R-S zoning designation. The density range required in the R-S zone is a minimum of 4.0 to a maximum of S.O dwelling units per acre (dulac). A two lot short plat of a 0.32 acre parcel would result in a density of 6.25 du/acre, which would be within the permitted density range in the R-S. After the 5' road dedication along Meadow Avenue, N. approximately 11,S62 sq. ft (.27 acres) remains, resulting in a density of 7.4 dulac. Therefore, the lot meets code requirements for a short plat. Minimum Lot Size, Width and Depth -The minimum lot size permitted in the R-S is 4,500 square feet for lots greater than 1 acre in size and 5,000 square feet for lots 1 acre or less in size. A minimum lot width of 50 feet for interior lots and 60 feet for comer lots, as well as a minimum lot depth of 65 feet, is also required. The total area of the proposed subdivision is less than 1 acre, so the minimum lot size is 5,000 square feet. At approximately 5,947 sq. ft. each, both lots appear to meet the minimum lot size requirement. Both lots meet the lot width and depth requirements. Building Standards -The R-S zone allows a maximum building coverage of35% of the lot area or 2,500 square feet, whichever is greater. Building height is restricted to 30 feet and 2-stories. Any detached accessory structure must be below a height of 15 feet and one-story. The gross floor area must be less than that of the primary structure. Accessory structures are also included in building lot coverage calculations. Detached accessory structures (garages, sheds, etc.) are Teets Short Plat Pre-Applicatio ..:ting March I, 2007 Page 2 of4 permitted at a maximum number of two per lot at 720 square feet each, or one per lot at 1,000 square feet in size. Setbacks -Setbacks are the minimum required distance between the building footprint and the property line or private access easement. The required setbacks in the R-8 zone are 15 feet in front for the primary structure; 20 feet in front for the attached garage; 20 feet in the rear; 5 feet for interior side yards; 15 feet for side yards along streets (including access easements) for the primary structure; and, 20 feet for side yards along streets (including access easements) for attached garages. The front yards of Lots 1 and 2 would be along Meadow Avenue, North. Both new lots would have adequate area to build a house and meet setback requirements. 'The rear yard for the proposed project abuts Interstate 405 and could possibly be ¥ impacted by the proposed widening of the highway. The applicant should contact Colleen . Gatz at the Dept. of Transportation for forther information 206-768-5792. AccesslParking -Street improvements, including, curbs, gutter and sidewalk, are required along of the frontage of properties when they are subdivided. The applicant may ask to have this requirement deferred, but a fee-in-lieu of would be required at a rate that it would cost the City to construct these improvements. The money would go to a general street improvement fund and not necessarily be used on improvements along the applicant's site. Both lots have street frontage that would provide direct access to a public street. Each lot must allow for the parking of two vehicles on the property. Street improvements along Meadow Avenue, N. would be required. Landscaping Landscaping is required along the frontage of all new short plats. A 5 ft. wide irrigated or drought resistant landscape strip is the minimum amount of landscaping necessary for a site abutting a ~~ non-arterial public street. A 5 ft. landscape strip will be required in the right-of-way, where f~ possible, and on the lots themselves where there is not enough space for the strip in the right-of- way. Landscaping must be installed prior to final plat approval and recording. In addition to the 5 ft. landscape strip requirement, the tree requirement for short plats is at least two trees of a City approved species with a minimum caliper of I 112 inches in the front yard or planting strip on every lot. The trees must be planted prior to building occupancy. Fences • A Conceptual Landscape Plan, showing the two trees per lot and the plantings in the 5 ft. landscape strip, as defined in RMC 4-8-120D must be submitted at the time of short plat application. A Detailed Landscape Plan will be required at submittal for final short plat review. Permitted fence height is 48" in the front yard and side yards along a street, and 72" in the rear yard and interior side yards. Fences cannot exceed 42" in height in the clear vision area of comer lots. Please see enclosed handout on fences for specific details. If the applicant intends to include a fence as part ofthe landscaping, please submit conceptual fence details along with the landscape plan. Critical Areas ., There is no indication of wetlands or streams on this site. Although the presence of sensitive ,U 0~~~1')7 slopes does not appear on City of Renton maps, there is a an existing retaining wall and a '1"' ~D . significant grade change between proposed Lots I and 2. The applicant would be required to submit a geotechnical report to address issues of soil stability and grading. \)\,1.1\\ \jf Teets Short Plat Pre-Application ng March I, 2007 Page 3 of 4 Significant Tree Retention A tree inventory and a tree retention plan shall be provided with the formal land use application. The tree retention plan must show preservation of at least 25% of significant trees [those with a minimum diameter of 8" (evergreen) or 12" (deciduous) when measured four feet above grade], and indicate how proposed building footprints will be sited to accommodate preservation of significant trees that will be retained. 'The site plan that was submitted appears to have trees on it, but they do not correspond with the location of trees that actually exist on site. Specifically, there is a large western hemlock in the SW corner of proposed Lot 2 that is possibly on the neighbor's property and would need to be protected. Consistency with the Comprehensive Plan The existing development is located within the Residential Single Family (RSF) Comprehensive Plan Land Use designation. The following proposed policies are applicable to the proposal: Land Use Element Objective LU-FF: Encourage re-investment and rehabilitation of existing housing, and development of new residential plats resulting in quality neighborhoods that: I. Are planned at urban densities and implement Growth Management targets, 2. Promote expansion and use of public transportation; and 3. Make more efficient use of urban services and infrastructure. Policy LU-149. Lot size should exclude private sidewalks, easements, private road, and driveway easements, except alley easements. Policy LU-150. Required setbacks should exclude public or private legal access areas, established through or to a lot, and parking areas. Policy LU-152. Single-family lot size, lot width, setbacks, and impervious surface should be sufficient to allow private open space, landscaping to provide buffers/privacy without extensive fencing, and sufficient area for maintenance activities. Policy LU-154. Interpret development standards to support new plats and infill project designs incorporating street locations, lot configurations, and building envelopes that address privacy and quality of life for existing residents. - Community Design Element Policy CD-12. Infill development, defined as new short plats of nine or fewer lots, should be encouraged in order to add variety, updated housing stock, and new vitality to neighborhoods. Policy CD-13. Infill development should be reflective ofthe existing character of established neighborhoods even when designed using different architectural styles, andlor responding to more urban setbacks, height or lot requirements. Infill development should draw on elements of existing development such as placement of structures, vegetation, and location of entries and walkways, to reflect the site planning and scale of existing areas. Permit Reqnirements To subdivide the lot, the applicant must make formal short plat submittal. A submittal checklist, listing the items that must be included in the submittal packet to the City, is included in the preapplication meeting packet of information. 'Once the short plat application materials are complete, the applicant is strongly encouraged to have one copy of the application materials pre-screened at the 6'h floor front counter prior to submitting the complete application package. Teets Short Plat Pre-Applicatio ;ting March 1, 2007 Page 4 of4 Short plats are processed administratively within an estimated time frame of 6 to 8 weeks for preliminary short plat approval. The application fee is $1,000,00, The applicant will be required to install a public information sign on the property. Detailed information regarding the land use application submittal is provided in the attached handouts. Once preliminary approval is received, the applicant must complete any required improvements, such as putting in sidewalks, a fire hydrant or grading. A separate construction permit is required for these improvements. The applicant must also satisfY any conditions of the preliminary approval before the plat can be recorded. The newly created lots may be sold only after the plat has been recorded. The applicant can submit for a building permit review for the new house before the short plat is recorded, but the City can only issue the building permit when the plat has been recorded. Fees In addition to the fees for review of the land-use, construction and building permits, the following mitigation fees would be required prior to the recording of the plat. • A Transportation Mitigation Fee based on $75.00 per each new average daily trip attributable to the project; and, • A Fire Mitigation Fee based on $488.00 per new single-family residence, • The R-8 zone permits one residential structure per unit per lot. The applicant would be required to obtain a demolition permit for the existing house. Demolition permits are valid for a period of six months. A handout listing all of the City's Development related fees in attached for your review, Expiration Upon preliminary short plat approval, the preliminary short plat approval is valid for two years with a possible one-year extension. cc: Jennifer Henning DEVELOPMENT PLANNINC SITY OF R~NTON 0 DEVELOPMENT SERVICES DIVISION WAIVER OF SUBMITTAL REQUIREMENTS FOR LAND USE APPLICATIONS SEP 1 1 2007 .... /:;J\/Erc , ~,~t:l'l.~f~' U his requirement may be waived by: Property Services Section Public Works Plan Review Section Building Section Development Planning Section PROJECT NAME: Tet?15 S;1-orz( fl.-Ifl DATE 8/~1 /0'7 DEVELOPMENT SERVICES DIVISION WAIVEu-o;: OF SUBMITTAL REQUIReMENTS FOR LAND USE APPLICATIONS Wireless: Applicant Agreement Statement 2 AND 3 Inventory of Existing Sites 2 AND 3 Lease Agreement, Draft 2 AND 3 Map of Existing Site Conditions •.•. ,Map of View Area 2 AND 3 Photosimulations 3 rhis requirement may be waive'd by: I. Property Services Section . '. Public Works Plan Review Section :. Building Section :'Development Planning Section PROJECTNAME: ________________________ __ DATE: ______________________ _ n-\WI=R\P\N\nFVsr=R\/\Fnrrn<::\PI~nnin(1\w:lh,&>rnfc:.llhmitt:::llrpn<:: 0Jll=: vIc: Page 1 of 1 Jayna Paradise From: Andrea Petzel [APetzel@cLrenton.wa.usj Sent: Wednesday, August 29, 2007 11 :24 AM To: Jayna Paradise Subject: Re: Teets Short Plat Yes, j'll waive it. Just bring a copy of this email when you submit the application materials. Andrea Petzel, Planner City of Renton -Development Services Division Renton City Hall -6th Floor 1055 South Grady Way Renton, WA 98057 425-430-7270 apetzel @c:i.r~nton. wa. us »> "Jayna Paradise" <jayna@paceng.com> 08/29/07 11:07 AM »> Andrea: Will you waive the requirement for the Flood Hazard Data for the Teets Short Plat (PRE07-012) (2 lot plat at 3612 Meadow Avenue N)? It is not located in a flood plain. . I have attached the waiver form for this project. Regards, Jayna Paradise Pacific Engineering Design, LLC 15445 53rd Avenue S., SUite 100 Seattle, WA 98188 206.431.7970 phone 206.388.1648 fax www.paceng.com 8/29/2007 DEV~LOPMENT PLANNING vlTY OF RENT0"! SEP I I 2007 RECEIVED DENSITY WORKSHEET City of Renton Development Services Division 1055 South Grady Way-Renton, WA 98055 Phone: 425-430-7200 Fax: 425-430-7231 1. Gross area of property: 1. rZ.ISI ) 2. Certain areas are excluded from density calculations. DEVELOPMENT PLANNING N SEP 1 1 2( 7 RECEIVE D square feet These include public roadways, private access easements serving 3 or more dwelling units, and critical areas.' Total excluded area:" 2. ---.:S=-=~=-9~_ square feet 3. Subtract line 2 from line 1 for net area: 3. ---!J\ \'.j:!.It..c"-JI~L-=--_ square feet 4. Divide line 3 by 43,560 for net acreage: 4. ---.:o~:z. ... -'--!..-_ acres 5. Number of dwelling units or lots planned: 5. __ ~ __ unitsllots 6. Divide line 5 by line 4 for net density: 6. _1--.:.......5=-__ d. u.lacre L. lots or units would result in a net density of /.5 dwelling units per acre. 'Critical Areas are defined as "Areas determined by the City to be not suitable for development and which are subject to the City's Critical Areas Regulations not including very high landslide areas, protected slopes, wetlands or floodways." Critical areas buffers are not deducted/excluded. *. Alleys (public or private) do not have to be excluded. R:\PW\DEVSERV\Forms\Planning\density.doc 0711 8/0jl GEOTECH CONSULTANTS, INC Celebrating 20 Years 1986-2006 Caden Homes, LLC 2838 -109th Avenue Southeast Bellevue, Washington 98004 Attention: Darcy Teets DEVELOPMENT PLANNING CITY OF RENTON SEP 1 1 2007 RECEIVED Subject: Transmittal Letter -Geotechnical Engineering Study Proposed Two-Lot Short-Plat 3612 Meadow Avenue North Renton, Washington Dear Mr. Teets: 13256 Northeast 20th Street, Suite 16 Bellevue. Washington 98005 (4Z5) 747-5618 FAX (425) 747-8561 July 27,2007 JN 07270 We are pleased to present this geotechnical engineering report for the proposed two-lot short plat to be constructed in Renton, Washington. The scope of our services consisted of exploring site surface and subsurface conditions, and then developing this report to provide recommendations for general earthwork and design criteria for foundations, retaining walls, temporary excavations. This work was authorized by your acceptance of our proposal, P-7380, dated July 3,2007. The attached report contains a discussion of the study and our recommendations. Please contae! us if there ara any questions regarding this report, or for further assistance during the design and construction phases of this project. Respectfully submitted, DRW:jyb GEOTECHNICAL ENGINEERING STUDY Proposed Two-Lot Short-Plat 3612 Meadow Avenue North Renton, Washington This report presents the findings and recommendations of our geotechnical engineering study for the site of the proposed residential short-plat to be located in Renton. We were provided with an existing topography map for the site that was prepared by Pacific Engineering Design and dated May 29, 2007. In addition to illustrating existing features, the map also indicates how the site will be separated Into two lots. In conversations with Mr. Darcy Teets of Gaden Homes, LLC, we understand that potentially the site will be graded so that each lot has a somewhat flat grade. The southern lot will be higher than the northem lot. Two-story residences will likely be constructed on the lots. If the scope of the project changes from what we have described above, we should be provided with revised plans in order to determine if modifications to the recommendations and conclusions of this report are warranted. SITE CONDITIONS SURFACE The Vicinity Map, Plate 1, illustrates the general location of the site in the Kennydale Area of Renton. The site is nearly rectangular, having approximately 108 feet of frontage on its western side along Meadow Avenue North and an average depth of about 112 feet. The northern portion of the site is developed with a residence and associated features. The southem portion is undeveloped and mostly covered with tall grass. However, there is a bare area on the eastern side of this portion; we understand from Mr. Teets Ihal a shed was once localed Ihere. An existing retaining wall separates the residence area from the soulhern portion. The wall appears to be in a poor condition in our opinion. The overall site slopes gently to moderately downward to Ihe north/northeast, having a maximum topographic relief of about 13 feet. Residential properties border the sile to Ihe north and south. The soulhern residence is located about 15 feet from the adjoining property line. The right-of-way for Interstate 405 borders the property to the easl. A relatively sleep slope, likely graded for the conslruclion of Ihe freeway, declines away from the eastern side of the site. SUBSURFACE The subsurface conditions were explored by excavating three tesl pits at the approximate locations shown on the Site Exploration Plan, Plale 2. Our exploration program was based on the proposed construction, anticipated subsurface conditions and those encountered during exploration, and the scope of work outlined in our proposal. The test pits were excavated on July 17, 2007 with a rubber-tired backhoe. A geotechnical engineer from our staff observed the excavation process and logged the test pits. "Grab" samples GEOTECH CONSULTANTS. INC. CadenHomes July 27, 2007 IN 07270 Page 2 of selected subsurface soil were collected from the backhoe bucket. The Test Pit Logs are attached to this report as Plates 3 and 4. Soil Conditions The test pit excavated in the southeastem portion of the site revealed approximately 2 feet of fill soil that included some small debris. Native soil was revealed below the fill at that location, and at the ground surface in the other two test pits. Below a thin mantle of topsoil, the native soil revealed consisted of loose, fine-grained, slightly silty sand with many organics and roots. At about 3 to 5 feet below the top of the native soil, the sand became loose to medium-dense. These depths correspond to 3 to 7 feet below the ground surface. Some silt layers were revealed in the lower portion of the sand. The test pits were excavated to the maximum explored depth of 6 to 10 feet. No large obstructions were revealed by our explorations. However, debris, buried utilities, and old foundation and slab elements are commonly encountered on sites that have had previous development. Groundwater Conditions No groundwater seepage was observed in the test pits. However, they were left open for only a short time period. Therefore, the level of the static groundwater level in the test pits may not be known. It should be noted that groundwater levels vary seasonally with rainfall and other factors. It is possible that some groundwater could be found perched above some silt layers in the sand soli during the normally wet winter and spring months. The stratification lines on the logs represent the approximate boundaries between soil types at the exploration locations. The actual transition between soil types may be gradual, and subsurface conditions can vary between exploration locations. The logs provide specific subsurface information only at the locations tested. The relative densities and moisture descriptions indicated on the test pit logs are interpretive descriptions based on the conditions observed during excavation. The compaction of backfill was not in the scope of our services. Loose soil will therefore be found in the area of the test pits. If this presents a problem, the backfill will need to be removed and replaced with structural fill during construction. CONCLUSIONS AND RECOMMENDATIONS GENERAL THIS SECTION CONTAINS A SUMMARY OF OUR STUDY AND FINDINGS FOR THE PURPOSES OF A GENERAL OVERVIEW ONL v: MORE SPECIFIC RECOMMENDA TlONS AND CONCLUSIONS ARE CONTAINED IN THE REMAINDER OF THIS REPORT. ANY PARTY REL YING ON THIS REPORT SHOULD READ THE ENTIRE DOCUMENT. The test pits conducted for this study encountered loose-native and fill soils down to approximately 3 to 7 feet below the ground surface. Native, loose to medium-dense sand was revealed below the loose soil. This native sand is suitable to support building loads founded on conventional footings, provided the footing bearing capacities are relatively light. The footings can also be placed on GEOTECH CONSULTANTS, INC. CadenHomes July 27, 2007 IN 07270 Page 3 structural fill that is placed over the loose to medium-dense sand. We recommend that the sand be compacted with vibratory equipment before any structural fill and/or footings are placed on it. The upper, loose soils revealed in the test pits are not suitable as structural fill because they contain too much debris and/or organics. The non-organlc sand below the loose soils may be used if the moisture is not too high or low. However, due to the fine-grained nature of the sand, it will have to be compacted in relatively small lifts (6 to 10 inches) with large vibratory equipment. The erosion control measures needed during the site development will depend heavily on the weather conditions that are encountered. While site clearing will expose a large area of bare soil, the erosion potential on the site is relatively low due to the gentle slope of the ground. We anticipate that 'a silt fence will be needed around the downslope sides of any cleared areas. Rocked construction access roads should be extended into the site to reduce the amount of soil or mud carried off the property by trucks and equipment. Wherever possible, these roads should follow the alignment of planned pavements, and trucks should not be allowed to drive off of the rock-covered areas. Existing catch baSins in, and immediately downslope of, the planned work areas should be protected with pre-manufactured silt socks. Cut slopes and soil stockpiles should be covered with plastic during wet weather. Following rough grading, it may be necessary to mulch or hydroseed bare areas that will not be immediately covered with landscaping or an impervious surface. The drainage and/or waterproofing recommendations presented in this report are intended only to prevent active seepage from flowing through concrete walls or slabs. Even in the absence of active seepage into and beneath structures, water vapor can migrate through walls, slabs, and floors from the surrounding soil, and can even be transmitted from slabs and foundation walls due to the concrete curing process. Water vapor also results from occupant uses, such as cooking and bathing. Excessive water vapor trapped within structures can result in a variety of undesirable conditions, including, but not limited to, moisture problems with flooring systems, excessively moist air within occupied areas, and the growth of molds, fungi, and other biological organisms that may be harmful to the health of the occupants. The designer or architect must consider the potential vapor sources and likely occupant uses, and provide sufficient ventilation, either passive or mechanical, to prevent a build up of excessive water vapor within the planned structure. Geotech Consultants, Inc. should be allowed to review the final development plans to verify that the recommendations presented in this report are adequately addressed in the design. Such a plan review would be additional work beyond the current scope of work for this study, and it may include revisions to our recommendations to accommodate site, development, and geotechnical constraints that become more evident during the review process. We recommend including this report, in its entirety, in the project contract documents. This report should also be provided to any future property owners so they will be aware of our findings and recommendations. SEISMIC CONSIDERATIONS In accordance with Table 1615.1.1 of the 2003 International Building Code (IBC), the site soil profile within 100 feet of the ground surface is best represented by Soil Profile Type 0 (Stiff Soil Profile). The site SOils are not susceptible to liquefaction due to the absence of near-surface groundwater. GEOTECH CONSULTANTS, INC. Caden Homes July 27, 2007 CONVENnONALFOUNDAnONS IN 07270 Page 4 The proposed structure can be supported on conventional continuous and spread footings bearing on undisturbed, loose to medium-dense, native sand soil, or on structural fill placed above this competent, native soil. Some overexcavation will likely be needed in foundation areas to reach this competent soil. The native sand should be compacted with vibratory eqUipment before the placement of the structural fill and/or footings. See the section entitled General Earthwork and Structural Fill for recommendations regarding the placement and compaction of structural fill beneath structures. Adequate compaction of structural fill shoUld be verified with frequent density testing during fill placement. Prior to placing structural fill beneath foundations, the excavation should be observed by the geotechnical engineer to document that adequate bearing soils have been exposed. We recommend that continuous and individual spread footings have minimum widths of 16 and 24 inches, respectively. Exterior footings should also be bottomed at least 18 inches below the lowest adjacent finish ground surface for protection against frost and erosion. The local building codes should be reviewed to determine if different footing widths or embedment depths are required. Footing subgrades must be cleaned of loose or disturbed soil prior to pouring concrete. Depending upon site and equipment constraints, this may require removing the disturbed soil by hand. Depending on the final site grades, overexcavation may be required below the footings to expose competent native soil. Unless lean concrete is used to fill an overexcavated hole, the overexcavation must be at least as wide at the bottom as the sum of the depth of the overexcavation and the footing width. For example, an overexcavation extending 2 feet below the bottom of a 2-foot-wide footing must be at least 4 feet wide at the base of the excavation. If lean concrete is used, the overexcavation need only extend 6 inches beyond the edges of the footing. An allowable bearing pressure of 2,000 pounds per square foot (psf) is appropriate for footings supported on soliS noted above. A one-third increase in this design bearing pressure may be used when considering short-term wind or seismic loads. For the above design criteria, it is anticipated that the total post-construction settlement of footings founded on competent native soil, or on structural fill up to 5 feet in thickness, will be about one inch, with differential settlements on the order of three-quarters of an inch in a distance of 50 feet along a continuous footing with a uniform load. Lateral loads due to wind or seismic forces may be resisted by friction between the foundation and the bearing soil, or by passive earth pressure acting on the vertical, embedded portions of the foundation. For the lalter condition, the foundation must be either poured directly against relatively level, undisturbed soil or be surrounded by level structural fill. We recommend using the fOllowing ultimate values for the foundation's resistance to lateral loading: Coefficient of Friction 0.40 Passive Earth Pressure 300 pcf Where: (i) pet Is pounds psr cubic foot, and (II) pa.slve earth pressure Is computed using the equivalent fluid density. GEOTECH CONSULTANTS, INC. CadenHomes July 27, 2007 IN 07270 Page 5 If the ground in front of a foundation is loose or sloping, the passive earth pressure given above will not be appropriate. We recommend maintaining a safety factor of at least 1.5 for the foundation's resistance to lateral loading, when using the above ultimate values. PERMANENT FOUNDATION AND RETAINING WALLS Retaining walls backfilled on only one side should be designed to resist the lateral earth pressures imposed by the soil they retain. The following recommended parameters are for walls that restrain level backfill: ------~,--- I' \R \~I[ nm I Active Earth Pressure· 35 pcf Passive Earth Pressure 300 pcf Coefficient of Friction 0.40 Soil Unit Weight 120 pet Where: (I) pet is pounds per cubic foot, and (II) active and passive earth pres.ur •• are computed using the equivalent fluid pressures. * For a restrained wall that cannot deflect at least O.QQ2 times Its height, a uniform lateral pressure equal to 10 psi time. the height of the wall should be added to the above active equivalent fluid pressure. The values given above are to be used to design permanent foundation and retaining walls only. It is not appropriate to back-calculate soil strength parameters from the earth pressures and soil unit weights presented in the table. The passive pressure given is appropriate for the depth of level structural fill placed in front of a retaining or foundation wall only. The values for friction and passive resistance are ultimate values and do not include a safety factor. We recommend a safety factor of at least 1.5 for overturning and sliding, when using the above values to design the walls. Restrained wall soil parameters should be utilized for a distance of 1.5 times the wall height from comers or bends in the walls. This is intended to reduce the amount of cracking that can occur where a wall is restrained by a corner. The design values given above do not include the effects of any hydrostatic pressures behind the walls and assume that no surcharges, such as those caused by slopes, vehicles, or adjacent foundations will be exerted on the walls. If these conditions exist, those pressures should be added to the above lateral soil pressures. Where sloping backfill is desired behind the walls, we will need to be given the wall dimensions and the slope of the backfill in order to provide the appropriate design earth pressures. The surcharge due to traffic loads behind a wall can typically be accounted for by adding a uniform pressure equal to 2 feet multiplied by the above active fluid density. Wall Pressures Due to Seismic Forces To model the surcharge wall loads that could be Imposed by the design earthquake, we recommend adding a uniform lateral pressure to the above-recommended active pressure. The recommended surcharge pressure is 8H pounds per square foot (psf), where H is the GEOTECH CONSULTANTS, INC. Caden Homes July 27, 2007 IN 07270 Page 6 design retention height of the wall. Using this increased pressure, the safety factor against sliding and overturning can be reduced to 1.2 for the seismic analysis. Heavy construction equipment should not be operated behind retaining and foundation walls within a distance equal to the height of a wall, unless the walls are designed for the additional lateral pressures resulting from the equipment. The wall design criteria assume that the backfill will be well-compacted in lifts no thicker than 12 inches. The compaction of backfill near the walls should be accomplished with hand-operated equipment to prevent the walls from being overloaded by the higher soil forces that occur during compaction. Retaining Wall Backfill and Waterproofing Backfill placed behind retaining or foundation walls should be coarse, free-draining structural fill containing no organics. This backfill should contain no more than 5 percent silt or clay particles and have no gravel greater than 4 inches in diameter. The percentage of particles passing the NO.4 sieve should be between 25 and 70 percent. If the native sand is used as backfill, a minimum 12-inch width of free-draining gravel or a drainage composite similar to Mlradrain 6000 should be placed against the backfilled retaining walls. The drainage composites should be hydraulically connected to the foundation drain system. The later section entitled Drainage Considerations should also be reviewed for recommendations related to subsurface drainage behind foundation and retaining walls. The purpose of tihese backfill requirements is to ensure that the design criteria for a retaining wall are not exceeded because of a build-up of hydrostatic pressure behind the wall. The top 12 to 18 inches of the backfill should consist of a compacted, relatively impenneable soil or topsoil, or the surface should be paved. The ground surface must also slope away from backfilled walls to reduce the potential for surface water to percolate into the backfill. The section entitled General Earthwork and Structural Fill contains recommendations regarding the placement and compaction of structural fill behind retaining and foundation walls. The above recommendations are not intended to waterproof below-grade walls, or to prevent the formation of mold, mildew or fungi in interior spaces. Over time, the perfonnance of subsurface drainage systems can degrade, subsurface groundwater flow patterns can change, and utilities can break or develop leaks. Therefore, waterproofing should be provided where future seepage through the walls is not acceptable. This typically includes limiting cold-joints and wall penetrations, and using bentonite panels or membranes on the outside of the walls. There are a variety of different waterproofing materials and systems, which should be installed by an experienced contractor familiar with the anticipated construction and subsurface conditions. Applying a thin coat of asphalt emulsion to the outside face of a wall is not considered waterproofing, and will only help to reduce moisture generated from water vapor or capillary action from seeping through the concrete. As with any project, adequate ventilation of basement and crawl space areas is important to prevent a build up of water vapor that is commonly transmitted through concrete walls from the surrounding soil, even when seepage is not present. This is appropriate even when waterproofing is applied to the outside of foundation and retaining walls. We recommend that you contact a specialty consultant if detailed recommendations or specifications related to waterproofing design, or minimizing the potential for infestations of mold and mildew are desired. GEOTECH CONSULTANTS, INC. CadenHomes July 27, 2007 IN 07270 Page 7 The General, Slabs-On·Grade, and Drainage Considerations sections should be reviewed for additional recommendations related to the control of groundwater and excess water vapor for the anticipated construction. SLABS·ON·GRADE The building floors can be constructed as slabs-on-grade atop firm, existing soil, or on structural fill. The subgrade soil must be in a firm, non-yielding condition at the time of slab construction or underslab fill placement. Any soft areas encountered should be excavated and replaced with select, imported structural fill. Even where the expos'ed soils appear dry, water vapor will tend to naturally migrate upward through the soil to the new constructed space above it. All interior slabs-on-grade must be underlain by a capillary break or drainage layer consisting of a minimum 4-inch thickness of gravel or crushed rock that has a fines content (percent passing the No. 200 sieve) of less than 3 percent and a sand content (percent passing the No.4 sieve) of no more than 10 percent. As noted by the American Concrete Institute (ACI) in the Guides for Concrete Floor and Slab Structures, proper moisture protection is desirable immediately below anyon-grade slab that will be covered by tile, wood, carpet. impermeable floor coverings, or any moisture-sensitive equipment or products. ACI also notes that vapor retarders, such as 6-mil plastic sheeting, are typically used. A vapor retarder is defined as a material with a permeance of less than 0.3 US perms per square foot (psf) per hour, as determined by ASTM E 96. It is possible that concrete admixtures may meet this speCification, although the manufacturers of the admixtures should be consulted. Where plastic sheeting is used under slabs, joints should overlap by at least 6 inches and be sealed with adhesive tape. The sheeting should extend to the foundation walls for maximum vapor protection. If no potential for vapor passage through the slab is desired, a vapor barrier should be used. A vapor barrier, as defined by ACI, is a product with a water transmission rate of 0.00 perms per square foot per hour when tested in accordance with ASTM E 96. Reinforced membranes having sealed overlaps can meet this requirement. In the recent past, ACI (Section 4.1.5) recommended that a minimum of 4 inches of well-graded compactable granular material, such as a 5/8 inch minus crushed rock pavement base, should be placed over the vapor retarder or barrier for protection of the retarder or barrier and as a "blotter" to aid in the curing of the concrete slab. Sand was not recommended by ACI for this purpose. However, the use of material over the vapor retarder is controversial as noted in current ACI literature because of the potential that the protection/blotter material can become wet between the time of its placement and the installation of the slab. If the material is wet prior to slab placement, which is always possible in the Puget Sound area, it could cause vapor transmission to occur up through the slab in the future, essentially destroying the purpose of the vapor barrier/retarder. Therefore, if there is a potential that the protection/blotter material will become wet before the slab is installed, ACI now recommends that no protectionlblotter material be used. However, ACI then recommends that, because there is a potential for slab cure due to the loss of the blotter material, joint spacing in the slab be reduced, a low shrinkage concrete mixture be used, and "other measures' (steel reinforcing, etc.) be used. ASTM E-1643-98 "Standard Practice for Installation of Water Vapor Retarders Used in Contact with Earth or Granular Fill Under Concrete Slabs" generally agrees with the recent AClliterature. We recommend that the contractor, the project materials engineer, and the owner discuss these issues and review recent AClliterature and ASTM E-1643 for installation guidelines and guidance GEOTECH CONSULTANTS. INC. CadenHomes July 27, 2007 IN 07270 Page 8 on the use of the protection/blotter material. Our opinion is that with impervious surfaces that all means should be undertaken to reduce water vapor transmission. The General, Permanent Foundation and Retaining Walls, and Drainage Considerations sections should be reviewed for additional recommendations related to the control of groundwater and excess water vapor for the anticipated construction. We recommend proof-rolling slab areas with a heavy truck or a large piece of construction equipment prior to slab construction. Any soft areas encountered during proof-rolling should be excavated and replaced with select, imported structural fill. EXCAVATIONS AND SLOPES Excavation slopes should not exceed the limits specified in local, state, and national government safety regulations. Temporary cuts to a depth of about 4 feet may be attempted vertically in unsaturated soil, if there are no indications of slope instability. However, vertical cuts should not be made near property boundaries, or existing utilities and structures. Based upon Washington Administrative Code (WAC) 296, Part N, the soil at the subject site would generally be classified as Type B. Therefore, temporary cut slopes greater than 4 feet in height should not be excavated at an inciination steeper than 1:1 (Horizontal:Vertical), extending continuously between the top and the bottom of a cut. The above-recommended temporary slope inclination is based on the conditions exposed in our explorations, and on what has been successful at other sites with similar soil conditions. It is possible that variations in soil and groundwater conditions will require modifications to the inclination at which temporary slopes can stand. Temporary cuts are those that will remain unsupported for a relatively short duration to allow for the construction of foundations, retaining walls, or utilities. Temporary cut slopes should be protected with plastic sheeting during wet weather. It is also important that surface water be directed away from temporary slope cuts. The cut slopes should also be backfilled or retained as soon as possible to reduce the potential for instability. Please note that sand can cave suddenly and without warning. Excavation, foundation, and utility contractors should be made especially aware of this potential danger. These recommendations may need to be modified if the area near the potential cuts has been disturbed in the past by utility installation, or if settlement-sensitive utilities are located nearby. All permanent cuts into native soil should be inclined no steeper than 2:1 (H:V). Fiii slopes should also not be constructed with an inciination greater than 2:1 (H:V). To reduce the potential for shallow sloughing, fill must be compacted to the face of these slopes. This can be accomplished by overbuilding the compacted fill and then trimming it back to its final inclination. Adequate compaction of the slope face is important for long-term stability and is necessary to prevent excessive settlement of patios, slabs, foundations, or other improvements that may be placed near the edge of the slope. Water should not be allowed to fiow uncontrolled over the top of any temporary or permanent slope. All permanently exposed slopes should be seeded with an appropriate species of vegetation. DRAINAGE CONSIDERATIONS Foundation drains should be used where (1) crawl spaces or basements will be below a structure, (2) a slab is below the outside grade, or (3) the outside grade does not slope downward from a GEOTECH CONSULTANTS, INC. Caden Homes July 27, 2007 IN 07270 Page 9 building. Drains should also be placed at the base of all earth-retaining walls. These drains should be surrounded by at least 6 inches of 1-inch-minus, washed rock and then wrapped in non-woven, geotextile filter fabric (Mirafi 140N, Supac 4NP, or similar material). At its highest pOint, a perforated pipe invert should be at least 6 inches below the bottom of a slab floor or the level of a crawl space, and it should be sloped for drainage. All roof and surface water drains must be kept separate from the foundation drain system. A typical drain detail is attached to this report as Plate 5. For the best long-term performance, perforated PVC pipe is recommended for all subsurface drains. As a minimum, a vapor retarder, as defined in the Slabs-On·Grade section, should be provided in any crawl space area to limit the transmission of water vapor from the underlying soils. Also, an outlet drain is recommended for all crawl spaces to prevent a build up of any water that may bypass the footing drains. No groundwater was observed during our field work. However, if seepage is encountensd in an excavation, it should be drained from the site by directing it through drainage ditches, perforated pipe, or French drains, or by pumping it from sumps interconnected by shallOW connector trenches at the bottom of the excavation. The excavation and site should be graded so that surface water is directed off the site and away from the tops of slopes. Water should not be allowed to stand in any area where foundations, slabs, or pavements are to be constructed. Final site grading in areas adjacent to building should slope away at least 2 percent, except where the area is paved. Surface drains should be provided where necessary to prevent pondlng of water behind foundation or retaining walls. GENERAL EARTHWORK AND STRUCTURAL FILL All building and pavement areas should be stripped of surface vegetation, topsoil, organic soil, and other deleterious material. It is important that existing foundation(s) be removed before site development. The stripped or removed materials should not be mixed with any materials to be used as structural fill, but they could be used in non-structural areas, such as landscape beds. Structural fill is defined as any fill, including utility backfill, placed under, or close to, a building, behind permanent retaining or foundation walls, or in other areas where the underlying soil needs to support loads. All structural fill should be placed in horizontal lifts with a moisture content at, or near, the optimum moisture content. The optimum moisture content is that moisture content that results in the greatest compacted dry density. The moisture content of fill is very important and must be closely controlled during the filling and compaction process. The allowable thickness of the fill lift will depend on the material type selected, the compaction equipment used, and the number of passes made to compact the lift. The loose lift thickness should not exceed 12 inches. We recommend testing the fill as it is placed. If the fill is not sufficiently compacted, it can be recompacted before another lift is placed. This eliminates the need to remove the fill to achieve the required compaction. The following table presents recommended relative compactions for structural fill: . GEOTECH CONSULTANTS, INC. CadenHomes July 27, 2007 Beneath pavements Where: Minimum Relative Compaction Is the ratio, expressed In percentages, of the compacted dry dansHy to the maximum dry density. as determined In accordance with ASTM Test Designation D 1557-91 (Modified Proctor). IN 07270 Page 10 The General section should be reviewed for considerations related to the reuse of on-site soils. Structural fill that will be placed in wet weather should consist of a coarse, granular soil with a silt Dr clay content of no more than 5 percent. The percentage of particles passing the No. 200 sieve should be measured from that portion of soil passing the three-quarter-inch sieve. LIMIT A TlONS The conclusions and recommendations contained in this report are based on site conditions as they existed at the time of our exploration and assume that the soil and groundwater conditions encountered in the test pits are representative of subsurface conditions on the site. If the subsurface conditions encountered during construction are significantly different from those observed in our explorations, we should be advised at once so that we can review these conditions and reconsider our recommendations where necessary. Unanticipated soil conditions are commonly encountered on construction sites and cannot be fully anticipated by merely taking soil samples in test pits. Subsurface conditions can also vary between exploration locations. Such unexpected conditions frequently require making additional expenditures to attain a properly constructed project. It is recommended that the owner consider providing a contingency fund to accommodate such potential extra costs and risks. This is a standard recommendation for all projects. This report has been prepared for the exclusive use of the Caden Horries, LLC, and its representatives, for specific application to this project and site. Our recommendations and conclusions are based on observed site materials, and engineering analyses. Our conclusions and recommendations are professional opinions derived in accordance with current standards of practice within the scope of our services and within budget and time constraints. No warranty is expressed Dr implied. The scope of our services does not include services related to construction safety precautions, and our recommendations are not intended to direct the contractor's methods, techniques, sequences, Dr procedures, except as specifically described in our report for consideration in design. Our services also do not include assessing Dr minimizing the potential for biological hazards, such as mold, bacteria, mildew and fungi in either the existing or proposed site development. GEOTECH CONSULTANTS, INC. CadenHomes July 27, 2007 ADDITIONAL SERVICES IN 07270 Page 11 In addition to reviewing the final plans, Geotech Consultants, Inc. should be retained to provide geotechnical consultation, testing, and observation services during construction. This is to confirm that subsurface conditions are consistent with those indicated by our exploration, to evaluate whether earthwork and foundation construction activities comply with the general intent of the recommendations presented in this report, and to provide suggestions for design changes in the event subsurface conditions differ from those anticipated prior to the start of construction. However, our work would not include the supervision or direction of the actual work of the contractor and its employees or agents. Also, job and site safety, and dimensional measurements, will be the responsibility of the contractor. During the construction phase, we will provide geotechnical observation and testing services when requested by you or your representatives. Please be aware that we can only document site work we actually observe. It is still the responsibility of your contractor or on-site construction team to verify that our recommendations are being followed, whether we are present at the site or not. The following plates are attached to complete this report: Plate 1 Vicinity Map Plate 2 Site Exploration Pia n Plates 3 - 4 Test Pit Logs Plate 5 Typical Footing Drain Detail GEOTECH CONSULTANTS, INC. CadenHomes July 27, 2007 IN 07270 Page 12 We appreciate the opportunity to be of service on this project. If you have any questions, or if we may be of further service, please do not hesitate to contact us. Respectfully submitted, GEOTECH CONSULTANTS, INC. Principal DRW: jyb GEOTECH CONSULTANTS, INC. stJIJffl POIHr LAKE GEOTECH CONSULTANTS, INC. • $ . COM/: \ Job No: 07270 ·, . I ~ I , VICINTYMAP 3612 Meadow Avenue North Renton, Washington I Date· JuIY2007 I Plate: No Scale _ No SC~~ tBf I ,-.. I " \ I \ \ Legend TP-2 1 ' I' , \ " , I ; " ~ I J Site Boundary Line '07" E 115, - -'·"l '-TP·3 , 18 0 -----[jjJ I ',-" I I I I LOT 1 I ~-~ 5 j BBO SF u-=Jmm_ .. , .. ,., Ho._ ~ ," -rm-,'--=l \, ........ WJ..L.,:J (" -j~ TP·1 ----184 _'. \ LOT 2 ". I 5,733 SF 1 \ \ \ \ '-. Adjacent House I "- .~ \ --1 --1 ~ ~ lJ.J i52 >-a:: ~ Q!i .. ) >-0 ~ .. .I: W ~ w 0: e: III 1:1 W .., I--W a:: (,) z 0 (,) [jjJ = Approximate Test Ptt location Ref: Teets Short Plat by Pa"fic Engineering Design, LLC Dated May 29, 2007 GEOTECH CONSULTANTS, INC. EXPLORATION SITE PLAN 3612 Meadow Avenue North Renton, Washington !JobNo: 07270 ! Date· ! ~UIY 2007 No Scale I Plate: 2 " . 5 10 15 5 10 15 --------i- l- i- i- i- i- L..... TEST PIT 1 Description Sandy FILL with debris fI~l~ I I I I I ~ I : Brown, slightly silty SAND, many organics, very moist, loose :::: :,:1: 1:lsp lilsM I:r:'~' 1:1: 11:1: I I : I: I I ~ I ~ I -becomes more tan Iii! :1:/:: No organics, very moist, loose to medium-dense II~ I ~ I: I: I IIII:I!' Some intermixed silt lavers 1I11I1 • Test Pit was terminated at 10 feet on July 17, 2007. • No groundwater seepage was observed during excavation. • No caving was observed during excavation, TEST PIT 2 Description -becomes more tan ,sP 'SM No organics, very moist, loose to medium-dense '" '" Some intermixed silt layers II II II II II II II II II II " , * Test Pit was terminated at 10 feet on July 17, 2007. * No groundwater seepage was observed during excavation. * No caving was observed during excavation. ___ .. ..t GEOTECH ., CONSULTANTS, INC. TEST PIT LOGS 3612 MEADOW AVENUE N Renton, Washington ~~~t~$~~P~~~~===-~ Job No: 07270 Date: Logged by: Plate: July 17, 2007 DRW 3 ... - i'" i- 5 ...... ... ---10 ----- 15 - TEST PIT 3 Description 1m ' :TOPSOIL 11:1: I!:I: : Brown, slightly silty SAND, with organics, moist, loose :1:1: :1:1: , , SP : • becomes more tan SM , , No organics, very moist. loose to medium·dense :1:1:1:1:1: : Some intermixed silt layers 111111 • Test Pit was terminated at 6 feet on July 17, 2007. • No groundwater seepage was observed during excavation. • No caving was observed during excavation. GEOTECH TEST PIT LOGS 3612 MEADOW AVENUE N Renton, Washington CONSULTANTS, INC. Job No: Date: Logged by: Plate: 07270 July 17, 2007 DRW 4 · . Slope backfill away from foundation. Provide surface drains where necessary. Backfill (See text for requirements) Washed KOI~K-l ..... (7/8" min. size) Tightline Roof Drain (Do not connect to footing drain) Vapor Retarder/Barrier and Capillary Break/Drainage Layer (Refer to Report text) NOTES: L-_ 4" Perforated Hard PVC Pipe (Invert at least 6 inches below slab or crawl space. Slope to drain to appropriate outfall. Place holes downward.) (1) In crawl spaces, provide an outlet drain to prevent buildup of water that bypasses the perimeter footing drains. (2) Refer to report text for additional drainage, waterproofing, and slab considerations. 4. ~~~t~~T~~=-==~~~ GEOTECH CONSULTANTS, INC. FOOTING DRAIN DETAIL 3612 MEADOW AVENUE N Renton, Washington Date: tate: July 17, 2007 5 August 17,2007 TEETS SHORT PLAT 3612 Meadow Avenue N. Renton, Washington Drainage Narrative Prepared for: Darcey Teets 2838 109th Ave Se Bellevue, WA 98004 (206) 391-1500 Prepared By: Pacific Engineering Design, LLC 15445 53rd Avenue South, Suite 100 Seattle, WA 98188 Phone: (206) 431-7970 Fax: (206) 388-1648 Joseph M. Hopper, P.E. DEVELOPMENT PLANNING CITY OF RENTON SEP 1 1 2007 RECEIVED PED Job No. 06089 Drainage Narrative/or Teets Sh 'Iat 811712007 TABLE OF CONTENTS 1. Project Overview ................................................................................................................... 1 II. Off-Site Analysis .................................................................................................................. .2 III. Core Requirements ................................................................................................................ .3 IV. Erosion / Sedimentation Control Design .............................................................................. .4 -;o---=--=--;-.---;-----;c; .• ~-.... _-_ .......... _ .. Pacific Engineering Design. LLC Page i \\bJade1425\Raid\Project Files\06089 Teets Short Plat\06089 Drainage Narrative.doc Drainage Narrative for Teets Sh lat 811712007 ----- I. Project Overview Site Location The site is located in Section 35, Township 24, Range 5E, W.M. in The City of Renton. Plat name of the site is Hillmans Lake Washington Garden of Eden No.2, plat lot 122. The King County Parcel Number is 3342700617. The site is more specifically located north of the intersection of Meadow Ave. N and N. 36 th St., on the east side of Meadow Ave. N. The existing lot size is 13,827 square-feet, which also equals 0.32 acres. The site is within the R-8 residential zone in, in the Kennydale Hill area of Renton, west ofI-405. The site is accessed from Meadow AvenueN. Project Description The site currently contains a single family residence with no garage or driveway. The south portion of the site is a grade bench that is approximately 5-feet higher than the existing building elevation. There appears to be the remains of a concrete pad on the bench where a detached garage or shed once stood. The site slopes steeply from the south bench toward the existing house. The site then moderately continues to slope to the north at approximately 5 to 8 percent. The rear of the lot abuts the 1-405 right-of-way. The sound barrier wall for 1-405 is located near the rear property line. This project proposes to divide the existing lot into two lots using the Short Plat process in accordance with City of Renton Municipal Code (RMC) Chapter 4-7-050. According to the zoning requirements (RMC 4-2-11 OA) the minimum density allowed in this area is 4 dwelling units per acre and the maximum density allowed is 8 dwelling units per acre. The total site area is 13,827 square-feet according to King County Assessor's records. A 5-foot right-of-way dedication is proposed along the frontage of the property, for an approximate area of 540 square- feet. The remaining developable property is 13,287 square-feet. Proposed Detention and Water Quality Facility Detention and Water Quality facilities are not proposed for this project. The 1990 King County Surface Water Design Manual allows an exemption from installing detention and water quality facilities if the development is below the minimum thresholds. The new impervious surface created by developing this property as described above does not result in more than 5000 sf of new impervious surface. The roof drains are proposed to be tight lined to the conveyance system within Meadow Avenue N. The roof drainage will be conveyed across the site through perforated pipes. These pipes will help facilitate groundwater recharge and will also provide a reduction in the release rate of storrnwater from the proposed site. Pacific Engineering Design. LLC Page J \\bladc1425\Raid\Project Files\06089 Teets Short Plat\06089 Drainage Narrative.doc Drainage Narrative for Teets Sh ">lat 811712007 II. Off-Site Analysis Upstream Tributary Area Off-site storm water does not currently enter the site and is not anticipated to do so in the future. Downstream Analysis The site is approximately Y, mile from Lake Washington. The site's stormwater runoff currently sheet flows to the west toward Meadow Ave. N. where it is collected within a system of catch basins and storm pipes and is conveyed to the north approximately 1 ,425-feet to May Creek. The flow continues within May Creek in a northwesterly direction for approximately 1,140-feet and outfalls to Lake Washington. !,'4,'1'r·.",·' .,.".! .. ,yJ'(~J JJ4'!:~""'''Y , . '." .'~'~"-'J!'~' X.'~!~~I~J W."! '~A>-'Itl ,".'.'~' '''-'''.''' 'f:."l.'.,"!·iJ -'<J.'~'YJ,~J'I :J.'{'<:l\~'~I~ l.Ir.>"'!OIC~~ -'!4J!l'<Jt'.'1 ... "I _",n Sf " ~J_'~_'!'YJ:"'!>(, , ~ II THZ!'''~:.tI !.·~_' .. ~%r!1 J.(4~"l(~~'! ' J34 ..... (1:',.'/ \,/lf8 ~~' !J'''''ll%'-,.' ... ~ "" F\I.l!TIISI A""""";~N':'" . _" .•.•. ' •. "".'1; t ! • ,( .. ." ~ ,-F ' : {' "{.',"'-W'" '~~.~:_~.,,-l..f) .·~!"."'$I!Y-'Ji """",.,,, '.-, -1.,·1"'"'''''''''' "41""'."'" ! !~J::-.~".14~ : !iI'J~YA'.'l' -' '~-''"~'''-':' 'J4.';,~-,.'J:! '~,'," I~'-,~:, ~d~~';RIC'"U ~~~9!j';iy'I."U ~~1I~R~J~'4:' ~~~~!,,\:J~J';~' e~!"''-'~I~'I.J'' Pacific Engineering Design. LLC ~ ~~:J~:~-"JJ:' ! 'I":'~':)(J! ~ , J,H'fl':4~1 3.!-jJ.".x;4~e ~ 3u.'tJt;'):n ... :, j • ... In'IS, Downstream Map (from King County iMap) \\bladeI425\Raid\Project Files\06089 Teets Short P]at\06089 Drainage Narrative.doc J~Y ,:·,,,,,, .. t{)!t>·l(·I-J !3~lic'J,,~O JJ~""'~:"'.'; ,. ""'~.:; ~,\ .. ~"L::::;; , .' .' i' J.",~' , •. Page 2 Drainage Narrative filr Teets Sh. lat 811712007 III. Core Requirements CORE REQUIREMENTS -SECTION 1.2 OF 1990 KCSWDM 1.2.1 CORE REQUIREMENT #1: Discharge at the Natural Location The proposed project's storm water will be discharged to the drainage system lying within Meadow Ave. along the frontage of the property. 1.2.2 CORE REQUIREMENT #2: Off-site Analysis This core requirement has been addressed elsewhere in this preliminary report. Please refer to the Off-Site Analysis Section (Section II). 1.2.3. CORE REQUIREMENT #3: Flow Control Not Required. A perforated roof drain system will provide a measure of flow control by infiltrating the stormwater into the ground. 1.2.4 CORE REQUIREMENT #4: Conveyance System Roof drains will be collected and conveyed to the drainage system within Meadow Ave. N. 1.2.5 CORE REQUIREMENT #5: Temporary Erosion & Sedimentation Control During construction of the infrastructure for the Teets Short Plat, temporary erosion control methods will be implemented to prevent sedimentation and erosion using the methods outlined in Section 1.2.5 of the KCSWDM. 1.2.6 CORE REQUIREMENT #6: Maintenance and Operations This requirement will be fulfilled by the property owner until bonds have been released and public drainage system(s) have been conveyed to The City of Renton. 1.2.7 CORE REQUIREMENT #7: Bonds and Liability Bonds and insurance in accordance with City of Renton requirements will be provided by or at the behest of the owner during site construction and until the construction has been approved by The City of Renton. 1.2.8 CORE REQUIREMENT #8: Water Quality Not Required. Pacific Engineering Design. LLC Page 3 \\bJade1425\Raid\Project Files\06089 Teets Short Plat\06089 Drainage Narrative.doc Drainage Narrative for Teets Sh {at 81/712007 IV. Erosion I Sedimentation Control Design Erosion and sedimentation control will be provided by utilizing BMPs selected from the 1990 King Connty Surface Water Design Manual. These BMPs may include silt fencing around the perimeter of the site, construction safety fencing, interceptor v-ditches, rock check dams, plastic sheeting of stockpiles, straw mulch, hydro-seeding, catch basin protection, and a rocked construction entrance. A Temporary Sedimentation and Erosion Control Plan is included as part of the construction documents detailing the means by which sediment and erosion control will be handled during construction. Pacific Engineering Design. LLC Page 4 \\blade142S\Raid\Project Files\06089 Teets Short Plat\06089 Drainage Narrative.doc PACIFiC L..r\IGII\lEERING DE:::iiGf\j ~ LLC ,,= = CIVIL ENGINEERING AND PLANNING CONSULTANTS August 20, 2007 Ms. Andrea Petzel City of Renton Development Services Diyision 1055 South Grady Way Renton, W A 98055 Subject: Teets Short Plat Construction Mitigation Narrative Dear Andrea: PED Project No.: 06089 On behalf of our client, Darcey Teets, the following is the Construction Mitigation Narrative for the Teets Short Plat, as required as part of the City of Renton Short Plat submittal checklist requirements. • Proposed Construction Dates (begin and end dates): Fall 2007 -Fall 2008 • Hours and Days of Operation: Construction activities will be limited to the hours between 7:00am and 8:00pm, Monday through Friday and 9:00am and 8:00pm Saturday. [n addition, haul hours are limited to the hours between 8:30am and 3:30pm Monday through Friday, unless approved in writing in advance by the development services division. • Proposed HaulinglTransportation Routes: 1-405 to NJOth Street to Park Avenue N. to N. 38 th Street to Meadow Avenue N. • Measures to be implemented to minimize dust, traffic and transportation impact, erosion, mud, noise and other noxious characteristics: Water Truck, Temporary Erosion Control Plan, Construction proposed during City of Renton permitted work hours. • Any special hours proposed for construction or hauling (i.e. weekends, late uigbts): None • Preliminary Traffic Control Plan: N! A. No frontage improvements proposed. nc rely, ;/1h;J . v/' / ' / &e Hopper .' /7 roject Manager cc: Darcey Teets DEVELOPMENT PLANNING CITY OF RENTON SEP 11 2007 RECEIVEiJ 'iV\N\N. pace~~g. corn ...... - FiLED FOR RECORD AT REQUEST OF, Secker , Feilberg, P.S. 520 pike Street, 12210 seattle, WA 98101-4~05 AFTER RECORDING RETURN TO, BECKER & E'EILaERG, P.S. 520 Pike Street 1221Q SeatUe, WA 98101 BifHi'93263 iJasE:PH/J06NSU~ December THIS EASEMENT is made and entered into this ~ day of ~r, 1333. David A. Johnson and (bereinafter "JohnBon"), real properties: Debra K. Johnson, husband and wife are the owners of the following described 'l'ract 121, Addition to ill Vol':.lu.e Washington and Billman's Lake Washington Garden of Eden Seattle No.2, according to the plat thereof 11 of Plat&~ pil:qC €4, in Ring County, (hereinafter "Parcel An) Tract 122, Billman's Lake Washington Garden of Bden Addition to Seattle No.2, according to the plat thereof in Volume lL of Plats, paqe 64, in Ring County, waBhington (hereinafter I'PaJ:eel Stt) Johnson hereby grants the following described Basement over a 3 portion of Pareel B for the benefit of Parcel A: s commencinq at the so~theast corner of Parcel B, thence westerly to the BQuthfHeBt corner of Parcel B, thence northerly aloog the western boundary of Parcel B 20 feet, thence easterly aD feet, thenCe northerly 2 ,feet, thence easterly to a point on the eastern boundary of Parcel B 22 feet from the point of beginning, thence 8ollther~y to the point of ~eginninq. The purpose of said Easement is exclusive use of a garaqe located in.gress and egresa to the garage. EXCISE TAXNOi REQUIRED ~j/rj~ \ page 1 of 3 DEVELOPMENT P CITY OF RE NNINC, ON SEP 1 1 2 07 RECE!'J D ~I , \ i i , ,- ]. " , i I ! \ , ,~. I j I '= == o • ~he owners of Parcel A shall be solely responsible for all coats associated with maintenance, repair, remodel, and upkeep of the ~aBement and any structures located ther~on. The only structure permitted on the EAsement is the existing garage which is approximately 22.6 feet by 15.6 feet. Any remodel to the existing garage shall be. done within its current dimensions {width, length and height}, or in accordance with the mutual agreement of the owners of Parcels A and B~ This Easement shall run with the lanQ and bind the parties' heirs, successors in interest, and 8ssigns. /44_ ~L.e-z,.. Debra K. Job or: . eOUliTY OF ) STATE OF WA~ I B., On this day erscnally appeared before me David A. Johnson to me known to be the individual described in and who executed the within and foregoing instrument and acknowledqed that be siglled the same as his free and voluntary act and deed for the Uuea. and purposes therein mentioned. AlVEN u't~!.J'Y hand and official .... 1 this 7' ~ day of :i>~'i:X0~;;,:\: ' 199:~~~ . ~ :~.: . .t\~':!1~R"1\C:!J' ~PUbiiC in and for t e ,ate of . 'u .~-",.::I:1s r3 h' ... 'd' t .. ' : .... p~'~n . .1' -,.; _.: ..... as ~n":li"0n! res~ ~g aL:j~Zi~~~ '-;.. \:;'.:-:"."" '" \tt': .•. ·,c 1 My COImlU.S8~On exp~res ". <!' ',.' lJ, ........ ;' '. () ' ....... \ .. . •........ ~ 1t'J.5\~ .. / Page 2 of 3 . " . .. .. , I I 1 I j I = .. o • , .. , ... STATE OF WASHINGTON .s. COtlN'l'Y OF ry On this day personally appeared before ~e Debra K. Johnson to me known to l:le the individual described in and whQ executed the within Bnd foregoinq instrument and acknowledged that she signed the same as her free and voluntary act and deed for the uses and pu~poseB therein mentioned. ~' ./J _ m:~ my hand It;nd. official seal this ~ ,1993. 7' day of I,: ctary Publi n and for ~state of washinqton! resid~nq at)[' < • r -4/ My ccmmisBl.On expl.res 6 -/,J . / ko page 3 of 3 1 I , I , I I j ! i .-, I ',~ I , i 1 I I 1 t ! I . ,.' DEVELOPMENT PLANNING CITY OF RENTON Bill Quast, Eastside Title Unit Manager Shawna R. Cruikshank, Sr. Title Officer Mitch Huntley, Title Officer' Suzanne Desseau, Title Officer Lisa Weber, Title Assistant· Rachel Bramsen, Title Assistant Direct: (425) 283-1420 • (866)290-5196 • Fax: (425) 637-9820 Email: etu@rainiertitle.com 1120 112'" Ave. N.E., Suite 440, Bellevue, WA 98004 lP'iLAT ClERTJIlFICATlE SEP 1 1 2007 RECEI'!ED Order Number: 430623 Certificate Fee: $350.00 Tax: $31.15 This Certificate does not purport to reflect a full report on condition of title and shall have no force or effect except as a basis for the Certificate applied for. NOTE:No search of general taxes or assessments has been made. This Eertificate isrestricled to the use ofthe adJressee and is not to be used as a basis for closing any transaction affecting title to said property. Liability of the Company is limited to the compensation received therefor. Title to said estate or interest in said land is at the effective date hereof vested in: Denney 1. Teets, and Robin D. Teets. husband and wife and Doris J. Pease, as her separate estate And is a Certificate for a Plat Certificate of the property described in Schedule A, attached. Exceptions: See Schedule B, attached. Records examined to: AUGUST 8, 2007 at 8:30 AM Rainier Title, By: Agent for Lawyers Title Insurance Corporation Bill Quast, Sr. Title Officer, Unit Manager Page [ of6 Order Number: 43062g SCHEDULE A Tract 122 ofC.D. Hillman's Lake Washington Garden of Eden Addition!o Seattle No.2, according to the plat recorded in Volume 11 of Plats at page 64, in King County, Washington. Except that portion lying within Secondary State Highway number 2-A. End of Schedule A Page 3 of6 Order Number: 430623 SCHEDULEB EXCEPTIONS I. Deed of Trust and the terms and conditions thereof: Grantor: Denney J. Teets, and Robin D. Teets, husband and wife and Doris J. Pease, as her separate estate Trustee: First American Title Insurance Company Beneficiary: PHH Mortgage Corp. fka Cendant Mortgage Corp. Original amount: $366,225.00 Dated: August 31, 2006 Recorded: September I, 2006 Recording No.: 20060901000922 2. Relinquishment of all easements existing, future or potential, for access, light, view and air, and all rights of ingress, egress and regress to, from and between the land and the highway or highways to be constructed on land conveyed by deed: To: State of Washington Recorded: May 24, 1956 Recording No.: 4695952 3. Easement and the terms and conditions thereof: Purpose: Use of garage and ingress and egress to said garage Area affected: a portion of said premises Recording No.: 9312102007 End of Schedule B Exceptions Page 4 of6 Order Number: 430628 Notes: A. Abbreviated Legal Description: Tract 122 ofC.D. Hillman's Lake Washington Garden of Eden Add to Seattle 2 B. Property Address: 3612 Meadow Avenue N. Renton, Washington 98055 Page50f6 Order Number: 430628 PRIVACY POLICY We Are Committed to Safeguarding Customer Information In order to better serve your needs now and in the future, we may ask you to provide us with certrun information. We understand that you may be concerned about what we will do with such information -particularly any personal Of financial infDlmatioo. We agree that you have a right to know how we will utilize the personal information you provide to us. Therefore, we have adopted this Privacy Policy to govern the use and handling of your personal information. Applicability Depending upon which of our services you are utilizing, the types of non public personal infonnation that we may collect include: • Infonnation we receive from you on applications, forms and in other communicalions to us, whether in writing, in person, by telephone or any other means; • Infonnation about your transactions with us. our affiliated companies. or others, and • Infonnation we receive from a consumer reporting agency. Use ofinformation We request infonnation from you for your own legitimate business purposes and not for the benefit of any nonaffiliated party. Therefore, we will not release your information to nonaffiliated parties except (1) as necessary for us to provide the product or services you have requested of us; or (2) as permitted by law. We may, however, store such information indefinitely, including the period aftcr which any customer relationship has ceased. Such information may be used for any internal purpose, such as quality control effons or customer analysis. We may also provide all of the types of non public personal infonnation listed above to one or more of our affiliated companies. Such affiliated companies include financial service providers, such as title insurers, property and casualty insurers, and trust and invcstment advisory companies, or companies involved in real estate services, such as appraisal companies, home warranty companies and escrow companies. Furthermore. we may also provide all the information We collect, as described above, to companies that perform marketing services on our behalf, on behalf of our affiliated companies, or to other financial institutions with whom we or our affiliated companies have joint marketing agreements. Former Customers Even if you are no longer our customer, our Privacy Policy will continue to apply to you. Confidentiality and Security We will use our best efforts to ensure that no unauthorized parties have access to any of your infonnation. We restrict access to nonpublic personal information about you to those individuals and entities who need to know that information to provide products or services to you. We will use our best efforts to train and oversee our employees and agents to ensure that your infonnation will be handled responsibly and in accordance with this Privacy Policy. We currently maintain physicaJ, electronic, and procedural safeguards that comply with federaJ regulations to guard your nonpublic personal infonnation. Page 6of6 Order Number: 430628 Order No, 430628 7tl11!11 soaa ..;-~$' lOT 2 '14~& .... . , " "l;;'~ u:rr ,-,. )07 ':o~ un if JJ6ID 5F <>110 .... "EN51' 1'''~' ~ LOT<$3-• • 11m SF 04'" 112U9' ..." N, 31TH BT. ,'-, . 2 .,,~ ... ");~ .. .• , {~ .. .~ iUD SF HOG SF .... -:;"'" '. '" -.. 1120 -112th Ave. NE. Suite 440, Bellevue, W A 98004 Phone (425) 637-0193 -. Fax (425) 462-6010 t N ./11 , , H I ~ .:'" , ~ ... ~ 1\ I ' !~1-1ml SF ; .. '*' , ,,;-'" , ">~~ I \~m ,f " I ~~. .... \, ", ,., , r:,: , I " ., "1:"'''' , " 10'$~ Sf '" •• .,.., ... , ~~i\\l¢ I " .. t~ , _. This sketch is provided without charge, for your information. It is not intended to show all matters related to the property including, but not limited to: area, dimensions, easements, encroachments or location of boundaries. It is not a part of, nor does it modity, the commitment/policy to which it is attached. The Company assumes NO LIABILlTY for any matter related to this sketch. Reference should be made to an accurate survey for further infonnation. AFFIDAVIT OF INSTALLATION OF PUBLIC INFORMATION SIGN City of Renton Development Services Division 1055 South Grady Way, Renton, WA 98055 Phone:42~7200 Fax: 425-430-7231 DEVELOPMENT PLANNINC' CITY OF RENTON STATE OF WASHINGTON ) ) COUNTY OF KING ) SEP 1 1 2007 RECEIVED ))1t-1?fE'/ ·It lee-iS .., being first duly sworn on oath, deposes and says: 1. On the ;-if day of £ -if' / ,20 tI ?-, I installed ---::;"..1_ public Information sign(s) and plaSticti1erbox on ~ located at 3G./.6 mea/llu) Ifrl "" for the following project: Project name 'b6JA:J~y fief) Owner Name 2. I have attached a copy of the neighborhood detail map marked with an ·x· to indicate the location of the installed sign. 3. Thislthese public information sign(s) wasJwere constructed and installed in locations in conformance with the requirements of ;pter 7, TiDe ~mzn Municipal ~~e~ .. __ Installer Signatur SUB~~~~N ~to before me this /~i ""'''' A.~. r--, 2D • 2~. . • .. "1--'" -J v \ ~ \.. .o"";·L~C :.% iLL j( ~.H6-v 'I./~'}(r"-){. iJmf.«' ~ .. ? ::~'~::~Q .. -< v~ .. --NOTARY PUBLIC in and for the State Washington, •••••• II' A III \ • ~..... residing at '&J k y'4( W ft- -"·'"H" ... ''''''' , My commission expires on Z -J 1· J 0 . Q:\WEB\PWIDEVSERV\Forms\Planning~lIbsign.doc 0512006 Printed: 09-06-2007 CITY OF RENTON 1055 S. Grady Way Renton, WA 98055 ---------- Land Use Actions RECEIPT Permit#: LUA07 -101 Payment Made: 09/06/200702:26 PM Receipt Number: Total Payment: 1,000.00 Payee: D. TEETS Current Payment Made to the Following Items: Trans Account Code Description Amount 5008 000.345.81.00.0004 Binding Site/Short Plat 1,000.00 Payments made for this receipt Trans Method Description Amount Payment Check 1007 1,000.00 Account Balances Trans Account Code Description Balance Due 3021 303.000.00.345.85 Park Mitigation Fee 5006 000.345.81.00.0002 Annexation Fees 5007 000.345.81.00.0003 Appeals/Waivers 5008 000.345.81.00.0004 Binding Site/Short Plat 5009 000.345.81.00.0006 Conditional Use Fees 5010 000.345.81.00.0007 Environmental Review 5011 000.345.81.00.0008 Prelim/Tentative Plat 5012 000.345.81.00.0009 Final Plat 5013 000.345.81.00.0010 PUD 5014 000.345.81.00.0011 Grading & Filling Fees 5015 000.345.81.00.0012 Lot Line Adjustment 5016 000.345.81.00.0013 Mobile Home Parks 5017 000.345.81.00.0014 Rezone 5018 000.345.81.00.0015 Routine Vegetation Mgmt 5019 000.345.81.00.0016 Shoreline Subst Dev 5020 000.345.81.00.0017 Site Plan Approval 5021 000.345.81.00.0018 Temp Use or Fence Review 5022 000.345.81.00.0019 Variance Fees 5024 000.345.81.00.0024 Conditional Approval Fee 5036 000.345.81.00.0005 Comprehensive Plan Amend 5909 000.341.60.00.0024 Booklets/EIS/Copies 5941 000.341.50.00.0000 Maps (Taxable) 5954 650.237.00.00.0000 Special Deposits 5955 000.05.519.90.42.1 Postage 5998 000.231.70.00.0000 Tax Remaining Balance Due: $0.00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 .00 DEVELOPMENT PLANNW", 0,ITY OF RFNT')~! '. SEP 1 1 2007 iiECEIVEO R0704724 VICINITY MAP ----Tl-:-Cs.---- N 40TH ST LAKE WASHINGTON ST ST ~I 34TH ST z z ~ N 32ND ST -<t: f-. ~ z So o a -<t: w ::; I/-1i'iS ITE ! -$-tJ N 30 TH -<t: ST z~~~~~--~+~--- u:: ::.:: ::> u:: CIl <{ D.. CERTIFICATE I (WE) HEREBY CERTIFY THAT I AM (WE ARE) THE OWNER(S) IN FEE SIMPLE OF THE LAND HEREBY PLATTED IN THIS SHORT PLAT. DARCEY TEETS ACKNOWLEDGMENT STATE OF WASHINGTON) )SS COUNTY OF KING ) ON THIS DAY PERSONALLY APPEARED BEFORE ME ________ _ _________ TO ME KNOWN TO BE THE PERSON(S) THAT EXECUTED THE FOREGOING INSTRUMENT, AND ACKNOWLEDGED THAT SAID INSTRUMENT TO BE THE FREE AND VOLUNTARY ACT AND DEED OF THE SAID PERSON(S), FOR THE USES AND PURPOSES THEREIN MENTIONED, AND ON OATH STATED THAT THEY WERE AUTHORIZED TO EXECUTE THE SAID INSTRUMENT. GIVEN UNDER MY HAND AND SEAL THIS _ DAY OF _______ , 20o_. -----------------NOTARY PUBLIC IN AND FOR THE STATE OF WASHINGTON RESIDING AT _________ . APPROVALS CITY OF RENTON EXAMINED AND APPROVED THIS ___ DAY OF _______ , 200 __ . ----------------- ADMINISTRATOR OF PLANNING/BUILDING/PUBLIC WORKS KING COUNTY -.--------- EXAMINED AND APPROVED THIS ___ DAY OF ______ , 20o __ . DEPARTMENT OF ASSESSMENTS KING COUNTY ASSESSOR DEPARTMENT OF ASSESSMENTS DEPUTY KING COUNTY ASSESSOR LEGAL DESCRIPTION PORTION OF THE S.E. 1/4, N. W 1//4, SECTION 32] TWP. 24 N., KING COUNTY, WASHINGTON FOUND MON. IN CASE VISITED MAY, 2007 I 1 , 1 ---Tl - . LO C\1 --t-- N 38TH ST RGE. 5 E., W M. 29 N. 1/4 CORNER-----a. ... SEC. 32-24-5 FOUND MON. IN CASE CITY OF RENTON # 1834 N: 196744.338 FEET E: 1303747.970 FEET I r---------------------------~~~v,-------+---------__________ ~I 20' 20' '::.. 20' ""'" 25' FENCE 1.8' S--, I 3.6' W FND IRC # 11332 0.09'S & 0.03·E OF CALC. COR. La'r 1 COVERED Fs I3.5' CHAIN CONCRETE\ LINK FENCE EAVE~~ I II (S SS'42'07"E 11:5.79'-SP 194/11) '\ SHED to ~-L2 ~,v S 88'44'07', E 115.66' .', •. -.L o \ --1{~~,~~~~~~~.~~~.~~~.~-125.00' -{----~ I I I 1 , -1:0.66'- 5' RIGHT OF WAY _ DEDICATION -1----..:+--;;~-l5d' 1 0' FRO~lT '" '.RD ov~~~fNGJ'1 --( "'--FENCE 1.0' S I 5' RIGHT OF WAY DEDICATION ---- - gr2 "'~~ I G 0:: 1 ~IO V BSBL (TYP) 2.0',. I ROOF . f-I-! Ct) I~;OVERHANG \0' (/) a· I") I LOT 1 10 [2.0'S ::::: .-I ~ "! ~ U') II [;j SET IRC #21 464 ~ ~ 0) g: :; r' '(.., r--. 2.0' OFFSET co ~~ := ~ L <'>' {~ " ~ !:>-[J) I") N "\ () " I 8 I 1'"'\ g; I ;:>-I ~ i'J <t: "! I Y --.J I ~ 4J cr 8 ~ ~ I ~ 0:: ~ ~~I~I -_____ ~S....;8;::8;:.;· 4~4:...;' 3:;:.::3::...··.·~-E=____:.~1 O~7:..:;. 9~2;,.' ___ ......;_:,.;_~I, ~ ._~I -<r: 'Ol (I)!~ ,.... lj \ 1--z,-<:'Inc-VI,;::;:: :· ... ~~-.i?" ~ I ~"; ~ t ""', ~ ~ I o~ _~'-.;-I ~ --'I~-,nl";U .:J"'DL \,.j i II'~~! ~ ~I ,.c::; ~ ., I 20' R:AR YA?D ;: I'~ ~ [J) ~ • I BSB~ (TYP.) ~.I . /<') 0 '-" ~~ C 0 (Xi ~I OJ :.:-CONC. SOUND (/) I -0 (/) I'i LOT 2 ~ 0 BARRIER WALL [J) U') I I U') en 5' L-_____ J II 20' I I I I I L1 \ \ I ,... -.... --. 105.' 9' _ \ I 25' - • \ I 11ti o ~ N cW 25' 20' 20'::" \ N 88'45'01" v; , 111.:~, / -7 ~FENCE 6 WO'JL~ FENCEJ I r' 0.2' S FENCE 0.4' S . ' FND IRC #11332 '-0.17'S & 0.11'E OF CAl_C. COR. LOT 1 LOT 2 --{---1 125.00' FND IRC #11382 0.19'S & 0.15'E OF CALC. COR. EAST LINE OF N.W. 1/4 SECTION 32-24-05 \ I ..... \ I I I , I ====~~~~~·=~~~~~~~~~rt~F1/~~~==~~~~\1 S .6"5"22" E 660.17' J V Ww I 'lo • 010 I ~ {:; ..q--..t-o , -.,... o Co) Zz '-' TRACT 122 OF C.D. HILLMAN'S LAKE WASHINGTON GARDEN OF EDEN ADDITION TO SEATTLE No.2, ACCORDING TO THE PLAT RECORDED IN VOLUME 11 OF PlATS AT PAGE 64, IN KING COUNTY, WASHINGTON. SEC. 32-24-5 FOUND MON. IN CASE N J 32 1\ CITY OF RENTON #266 EXCEPT THAT PORTION LYING WITHIN SECONDARY STATE HIGHWAY NUMBER 2-A. S URVEYO H' S_..QERTIFICATE_ THIS MAP CORRECTLY REPRESENTS A SURVEY MADE BY ME OR UNDER MY DIRECTION IN CONFORMANCE WITH THE REQUIREMENTS OF THE SURVEY RECORDING ACT AT THE REQUEST OF DARCEY TEETS IN MAY, 2007. RECOHDER~~EHTIFICATE_ FILED FOR RECORD THIS __ DAY OF ________ , 20 __ AT __ M. IN BOOK _____ OF ______ AT PAGE _____ _ AT THE REQUEST OF RODNEY G. HANSEN. N: 191429.837 FEET E: 1303590.024 FEET 5 ('-'-------T-E-.E-T'-S-S-H-O-R-T-P-LA-T---------r--- PREPARED BY: It :3. E. 1/4, N. W. 1/4, SEC. 32, TWP. 24 N., RGE. 5 E., W. M. CITY OF RENTON, KING COUNTY, WASHINGTON CITY OF RENTON FILE No. LUA 07-101, SHPL-A ,. ~-------'""T'---------'""T'----------t ., Ii DWNBY: 5/14/0'7 PJC DATE: JOB NO. 20'714 j ~----------------~-----------~-------------~ 0' SHORT PLAT NO. LUA-07-101-SHPL-A LND~ xx-xxxx N I 1" 30' 30' 60' -------- - NAD 1983/91 BEARING SITE ADDRESS: 3612 MEADOW AVE N .. RENTON, WA 98056 ORIGINAL. TAX PARCEL # 3342700617 LEGEND .... = SECTION CORNER I = QUARTER CORNER ~ = FND. MON. IN CASE o = FND. PROP. COR. AS NOTED • = SET 1/2" I.R. W/CAP #21464 @ = SET PK W/FLASHER #21464 (COR) = CITY OF RENTON (R) = RECORD (P) = PLAT BSBL = BUILDING SETBACK LINE SURVEY MEETS OR EXCEEDS THE REQUIREMENTS OF WAC 332-130-090. EQUIPMENT USED: 5" TOTAL STATION. SURVEY METHOD: FIELD TRAVERSE. RELA llVE POSITIONAL TOLERANCE OF SET CORNERS: +/-0.1' LOT AREAS LOT 1 5,880 S.F. OR 0.14 Ac. + /- LOT 2 5,733 S.F. OR 0.13 Ac. + /- R.O.W. DEDICATION 538 S.F. OR 0.01 Ac. +/- TOTAL AREA 12,151 S.F. OR 0.28 Ac. +/- NEW LOT ADDRESSES LOT 1 xxxx ~A::::ADOW AVE N, RENTON, IVA 98056 LOT 2 xxxx MEADOW AVE N, .REN 7 0N. IVA. 98056 LINE Li L2 NOV 1 2 2008 RECEIVED llNE TABLE BEARING DISTANCE S 88'45'01" E 20.00' S 88'44'07" E 20.00' EXPIRES: 1/31 /10 ~ ) "JI";N LATEST REVISION: 09/02/08 HANSEN SURVEYING (J;1,'I .• rJ i,i/:1.i , LAND SURVEYORS & CONSULTANTS /, .•. iJ ~A~~~A~N~SE-N--====== CERTIFICATE No. 21464 MANAGER SUPT. OF RECORDS \ ; CHKD BY: RGH SCALE: 1"=20' SHEET 1 OF 1 17420 116TH AVE. S.E., RENTON, WA 98058 TEL: 425-235-8440 FAX: 425-235-0266 I ~------------------------------------~-------------------------------------.--------------~----------------------------------------------------------------------~ .. . ., ., ' .. I· " '"