HomeMy WebLinkAboutPN_Project Narrative_180213INNOVA Architects Inc. (253) 572-4903 950 Pacific Avenue, Suite 450 Tacoma, WA 98402 Page 1 of 3
PROJECT NARRATIVE
February 13, 2018
Planning Division
City of Renton
1055 South Grady Way
Renton, WA 98057
Project Name:
601 Monster Road SW Building and Site Redevelopment
Land Use Permits Required:
SEPA, demolition permit, site development permit, building permit, NPDES, SWPPP
Zoning Designation:
Industrial Medium (IM), adjacent properties are like zoning and use. Property to the east,
opposite side of right-of-way is Industrial Heavy.
Current Use of Site and Existing Improvements:
The site is a 9.61 acre industrial parcel (242304-9008) located at 601 Monster Road SW.
The existing concrete tilt-up warehouse building was most recently used by Graphic
Packaging and is a 143,862 SF footprint with a small portion of this being a single story
office. To the south of the main building is a small shop facility building. The developed
portions of the site are generally flat and allowed for the maneuverability of large semi-
trucks. There is a portion of the site used for vehicle parking to the southeast of the
building that is slightly elevated. Beyond the southern development limits of the site the
grades climb toward and onto the adjacent land parcel.
Special Site Features:
A majority of the site is relatively flat but sits lower than the adjacent south parcel and
right-of-way to the east. Adjacent property grades fall onto the project site from slight
slopes to as great as 40%. No development is proposed within these steep slope areas.
Statement addressing Soil Type and Drainage Conditions:
Test pit data has been provided as part of the soils investigation developed by Terra
Associates Inc. It identifies site soils for most of the site as fill material, averaging about
5 feet deep; underlain by soft to dense interbedded alluvial soils.This site and the
surrounding properties within the same drainage basin are part of an existing “Regional
Detention Facility Pump Station Agreement” created in 1995. This facility mitigates the
stormwater quantity aspect of the overall stormwater management. This project will
continue to provide water quality for impervious surfaces subject to vehicle traffic.
INNOVA Architects Inc. (253) 572-4903 950 Pacific Avenue, Suite 450 Tacoma, WA 98402 Page 2 of 3
Proposed Use of the Property and Scope of the Proposed Development:
Redevelopment of the site would involve reconfiguring the building footprint to increase
functionality, clear height and floor area as well as all new site utility infrastructure. The
proposed building would be a 32’ interior clear height tilt-up warehouse with an
approximate footprint of 161,320 SF. The site and building site would be designed to
implement a 4 foot deep truck well along the east dock face of the building. Paved
vehicle parking throughout the site will be provided to meet required stall quantities by
use and trailer stalls will be added in the truck dock operations area. The completed
building effort would create a speculative warehouse shell and would in the future permit
for tenant improvements of specific lease users.
For Plats Indicate the Proposed Number, Density and Range of Sizes of New Lots:
Not Applicable.
Access:
Existing-The site is currently served by four points of access. One drive serves the
existing east parking and truck service areas at Monster Road accessed by SW. A second
drive (of two driveways) serves the north parking area at the existing office area. The last
point of access is from a private drive along the west face of the building which connects
to a south drive lane along the existing building.
Proposed- The intent is to retain all four of these access points. The north access serving
the prior parking lot is being re-allocated for auto parking and a truck drive connection to
the east truck court area.
Proposed Off-site Improvements:
The City of Renton has indicated frontage improvements, including those in the right-of-
way, may be required along both the east and north property lines that abut the Monster
Road SW right-of-way. These have been defined in the pre-application notes from the
city. The applicant is seeking a modification to the orientation of these improvements.
Total Estimated Construction Cost and Estimate Fair Market Value:
Estimated project costs are currently assumed to be eight million. Market value to be
determined upon completed project timing.
Estimated Quantities and Type of Materials Involved if any Fill or Excavation is Proposed:
It is expected that a minimal amount of material will be moved for either fill or
excavation. Only structural fill under the building or parking is expected to be brought
onto the site.
Number, Type and Size of any Trees to be Removed:
A complete arborist assessment and report has been prepared and coordinated with
landscape plans defining the quantity and replacement value of trees for the project.
Approximately 135 trees are being proposed for removal (2 in ROW and 27 dangerous).
Explanation of any Land to be Dedicated to the City:
Due to required frontage improvements, there will be areas of right-of-way dedication to
fully construct the required frontage improvements.
Any Proposed Job Shacks, Sales Trailers and/or Model Homes:
The general contractor for the project will establish a temporary work trailer office.
INNOVA Architects Inc. (253) 572-4903 950 Pacific Avenue, Suite 450 Tacoma, WA 98402 Page 3 of 3
Any Proposed Modifications Being Requested:
The applicant will be seeking modification along two sections of Monster Road SW.
They are related to the orientation of sidewalk next to the curb. This is to maintain
existing sidewalk alignment along these sections of roadway and reducing or eliminating
walls height along a steep section of the site. A second modification will be sought to
retain existing sheet drainage at the eastern parking area, thus reducing the required
parking landscape islands. This is to not have to reconstruct an entire existing parking are
that is otherwise functional.