HomeMy WebLinkAboutS-392105T
N
0)
(Y)
N
roll
U
W
V_
L
r
LJJ
D
Stantec
1687 114TH Avenue SE, Suite 100 Bellevue WA
98004 phone: (425) 869-9448 www.stantec.com
PUGET SOUND \ \
ENERGY \\ \
-
\\`?,per
F'UUL I SUUNU
ENERGY
lam'
co CLUSTER OF 4 —
_ \ \ 16"MP
1 25
CO
41 1g+0 - -
SSMH 2706
RIM= 201.05
IE NE= 191.65
IE SW= 19�.45
LV VL VI
FLOWING WATER--.
EXPOSED 12"ADS
0000
EAGLE RIDGE ESTATES
NW 20-23-05
THUNDER HILLS CREEK
-REMAINS OF
GABION WALL
C/)
1 OF 1 �0V
P C0
K�
'\ co
9 013
9012 9116
L L
�� l 7� \ \ \�EDG� OF EX-\J 266 `—�� _ 14 NttP
GAVEL ROAD \ I I I 1 \ 8 U)
SWALE CUT
ACROSS TRAIL
BF 3p �� IN FOR RUN OFF
f
--� �_ -I-
/
EDGE OF 21 \\
FLOWING /WATER
+��3F�
K -.E C�10"
w
25 —� 3
6 AIR ' ' ! � �/ l �/ _%% J ✓/� ROCKERY � � ` � � / 2 0 //�
210
215.. % %/// '�Z � _ 225 ✓// • \' ., �--�j� �� THUNDER HILLS CREEK EDGE OF ?3p / FIN WATER �\
\�. � •'� // /� / FLOWING WATER � � � EDGE OF
\ „ I I
\\. 16 R / I I WETLAND
SSMH 2323
BOUNDARY FOOT BRIDGE 8"DI SUSPENDED FROM
24 �\
SDI \\
IE 12"CONC N= 208.12
INLET NOT LOCATED
EDGE OF
FLOWING WATER
SCALE
20 0 20 40
(FEET)
1 INCH = 20 FT
_2H� E \ �� (TYP) I TOP OF BRIDGE
TOP NE= 228.34
V TOP SW= 231.65
ROCK WEIR
—TOP/BACK EDGE /
REMAINS OF 3.5'W I
GABION WALL
TREE
TO BE REMOVED
TREE
REMOVAL SCHEDULE
15
12"
CEDAR
0
16
16"
CEDAR
0
17
20"
MAPLE
O2
18
18"
MAPLE
O2
�9
18"
MAPLE
O2
20
18"
MAPLE
O2
21
18"
MAPLE
O2
22
12"
MAPLE
O2
23
14"
MAPLE
O2
24
16"
ALDER
O2
25
16"
MAPLE
O2
26
16"
MAPLE
O2
27
18"
MAPLE
O2
28
18"
MAPLE
O2
NOTE:
0
REFER TO SHEET W5.1, MATERIAL SPECIFICATIONS NOTES
AND TABLE FOR ANCHORING DETAILS. ANCHORED LARGE
WOODY DEBRIS SHALL BE CONSTRUCTED UTILIZING CEDAR
WOOD FROM ONSITE SOURCES WHICH ARE DESIGNATED
FOR REMOVAL.
O2 ONSITE TREES LESS THAN 30" DBH WILL BE UTILIZED
AS UNANCHORED LARGE WOODY DEBRIS. PLACEMENT
TO BE DETERMINED BY CITY PROFESSIONAL AT THE
TIME OF RESTORATION.
O3 ONSITE TREES 30" DBH OR GREATER WILL BE UTILIZED
TO SUPPORT TERRESTRIAL HABITAT IMMEDIATELY
ADJACENT TO THE CHANNEL. PLACEMENT TO BE
DETERMINED BY CITY PROFESSIONAL AT THE TIME OF
RESTORATION
EXISTING CONTOUR INTERVAL = 1 FOOT
S-392105
KEY MAP
Stantec was not present on site during construction. These
record drawings are a compilation of a copy of the sealed
engineering drawings for this project, as modified by
information furnished by the as -built survey on the project.
The information shown on the record drawings that was
provided by the City Utilities Dept. inspector cannot be
verified for accuracy or completeness. The original sealed
drawings are on file at the offices of the City of Renton.